    Technical Specifications

    May 2015

    Royal Albert Hall

    Kensington GoreLondonSW7 2AP020 7589 3203www.royalalberthall.com

  • 8/17/2019 Royal Albert Hall Analisis

    2/30

     

    Royal Albert Hall Technical Specifications Page 2 of 30

    Figure 1 – The Royal Albert Hall Auditorium

    About This Document 

    These Technical Specifications are a guide to the majority of the technical services offered and facilitiesavailable at the Royal Albert Hall, London.

    This information is meant as a guide to incoming companies and productions, but is not exhaustive soshould not be used in isolation. The information is subject to change without notice.

    All events coming to the Hall will be assigned a dedicated Technical Show Manager (TSM) to oversee the

    production, please consult with them for all aspects of your technical requirements, for more informationand for hire prices where applicable.

    This document and more are available electronically via our website www.royalalberthall.com/about orcontact your TSM.

  • 8/17/2019 Royal Albert Hall Analisis

    3/30

     

    Royal Albert Hall Technical Specifications Page 3 of 30

    ABOUT THIS DOCUMENT ..................................................................................................................................................... 2 

    TECHNICAL CONTACTS ....................................................................................................................................................... 4 

    RIGGING SPECIFICATION .................................................................................................................................................... 6 

    OVERVIEW ...................................................................................................................................................................................... 6 DEFAULT CHAIN HOIST RIG PLAN.................................................................................................................................................. 6 CHAIN HOISTS ................................................................................................................................................................................ 7 

    TRUSSING ....................................................................................................................................................................................... 7 CIRCLE AND GALLERY .................................................................................................................................................................... 7 

    LIGHTING SPECIFICATIONS ................................................................................................................................................ 8 

    OVERVIEW ...................................................................................................................................................................................... 8 FURTHER INFORMATION ................................................................................................................................................................. 8 LIGHTING INFRASTRUCTURE .......................................................................................................................................................... 8 LIGHTING EQUIPMENT LIST ............................................................................................................................................................ 9 LIGHTING RIG PLAN ...................................................................................................................................................................... 10 

    POWER SPECIFICATIONS .................................................................................................................................................. 11 

    OVERVIEW .................................................................................................................................................................................... 11 SHOW & TECH POWER PANELS................................................................................................................................................... 11 FOH POWER ................................................................................................................................................................................. 11 RIGGING POWER ........................................................................................................................................................................... 11 OUTDOOR POWER ........................................................................................................................................................................ 12 OUTSIDE BROADCAST POWER ..................................................................................................................................................... 12 

    STAGE SPECIFICATION...................................................................................................................................................... 13 

    STAGE & ARENA DIMENSIONS ..................................................................................................................................................... 13 STAGE INFORMATION  ................................................................................................................................................................... 14 LIFT INFORMATION ........................................................................................................................................................................ 15 LIFT A (ARENA) ................................................................................................................................................................................. 15 

    LIFT B (BROAD) ................................................................................................................................................................................. 15 

    LIFT C (CONTINGENCY) ....................................................................................................................................................................... 15 

    COMMS SYSTEM ........................................................................................................................................................................... 16 

    SOUND SPECIFICATION ............................................................................................................... 17 

    CONTROL ...................................................................................................................................................................................... 17 PA SPEAKER SYSTEM SPECIFICATION ........................................................................................................................................ 18 ALTERNATIVE SPEAKER CONFIGURATIONS ................................................................................................................................. 18 

    AV SOLUTIONS .................................................................................................................................. 19 

    HEALTH AND SAFETY SPECIFICATIONS ....................................................................................................................... 22 

    HARD HAT SAFE WORKING PRACTICE –  OVERVIEW .................................................................................................................. 22 PERSONAL PROTECTIVE EQUIPMENT .......................................................................................................................................... 22 ROOF ACCESS –  OVERVIEW ........................................................................................................................................................ 22 EMERGENCY BEACON .................................................................................................................................................................. 23 RISK ASSESSMENTS ..................................................................................................................................................................... 23 SAMPLE RISK ASSESSMENT FORM .............................................................................................................................................. 24 

    APPENDIX 1 – USEFUL MEASUREMENTS ...................................................................................................................... 25 

    LOAD-IN ........................................................................................................................................................................................ 25 

    STAGE ........................................................................................................................................................................................... 25 ARENA  .......................................................................................................................................................................................... 25 OTHER .......................................................................................................................................................................................... 25 

    APPENDIX 2 – LOADING REFERENCE ............................................................................................................................ 26 

  • 8/17/2019 Royal Albert Hall Analisis

    4/30

     

    Royal Albert Hall Technical Specifications Page 4 of 30

    APPENDIX 3 – STANDARD TRIM HEIGHTS ..................................................................................................................... 26 

    APPENDIX 4 – RADIO MIC FREQUENCIES RESERVED BY THE HALL  ...................................................................... 26 

    APPENDIX 5 – ANCILLARY PATCHING ........................................................................................................................... 27 

    VIDEO & CAMERA PATCHING ....................................................................................................................................................... 27 

    Technical Contacts

    Senior Technical Manager  Ollie Jeffery 020 7959 [email protected]

    Lighting Design & Systems Manager Richard Thomas 020 7959 [email protected]

    Rigging Manager  Alexander Tripp 020 7959 [email protected]

    Technical Operations Manager  Gareth Jones 020 3036 [email protected]

    Technical Show Manager  Steph Baldwin 020 3036 [email protected]

    Technical Show Manager  John Quigley 020 7959 0537 [email protected]

    Technical Show Manager Oli Clark 020 7959 [email protected]

    Venue Technician   Chris Tanner 020 7589 3203 Ext. [2504][email protected]

    Venue Technician Chris Tibble 020 7589 3203 Ext. [2561][email protected]

    Venue Technician Ian Redding 020 7589 3203 Ext. [2516][email protected]

    Venue Technician   Jakub Drewa 020 7589 3203 Ext. [2516][email protected]

    Lighting Technician Dan Shelley [email protected] Technician  Drew Bristow [email protected]

    AV Partners SFL Group 0118 969 [email protected]

    Sound Partners Delta Sound 020 8339 [email protected]

  • 8/17/2019 Royal Albert Hall Analisis

    5/30

  • 8/17/2019 Royal Albert Hall Analisis

    6/30

     

    Royal Albert Hall Technical Specifications Page 6 of 30

    Rigging Specification 

    OverviewOwing to the closed nature and height of the roof, the Hall’s basic motor rig is available to incomingproductions at no extra cost. All rigging must be carried out in accordance with our Rigging Code ofPractice and in conjunction with your Technical Show Manager.

    The Hall’s motors are controlled using a custom Kinesys touchscreen system from stage level, which isoperated by your Technical Show Manager during load ins and outs. Most standard points are also fittedwith load cells and position encoders with all information fed back live to the operator.

    Default Chain Hoist Rig Plan

    Figure 3 – Chain Hoist Rig Plan

  • 8/17/2019 Royal Albert Hall Analisis

    7/30

     

    Royal Albert Hall Technical Specifications Page 7 of 30

    Chain Hoists

    •  18 Permanently rigged 2t Liftket motors situated as per the rigging plan•  42 Permanently rigged 1t Liftket motors situated as per the rigging plan•  29 Permanently rigged 1t Liftket motors supporting the lighting trusses

    (Trusses 1-4, the Advance truss and the circular corona truss)

    The following motors are also available if required, at a cost per point, to be rigged in specific points located

    on the rigging plan. Please consult with your Technical Show Manager for positions and availability.

    •  8x 2t Liftket motors•  12x 1t Liftket motors•  6x 500kg Liftket motors

    TrussingThe 4 over stage trusses are “type A steel” general purpose 52cm truss painted black. The Advance trussis black GP52 type aluminium truss. All trusses are permanently rigged with the house lighting rig, and canbe used for under slinging an additional U.D.L. of 2 tonnes.

    Truss LengthsAdvance Truss 13 metersTruss 1 16 metersTruss 2 16 metersTruss 3 15 metersTruss 4 13.5 meters

    There is a permanently rigged Circular Corona truss. This is black Prolyte H30v (6m external diameter)rigged on four points beneath the corona.

    We also hold in stock a “Slot” truss; this can sit in front of the organ on the “T” motors, following the backline of stage. This consists of 10 x 3m lengths of black Prolyte H30d triangular truss, with 4 custom 30dbook corners. This truss is not permanent and will incur a charge if required, please consult with your TSMfor more information.

    Circle and GalleryThe Circle bar is a curved steel bar that runs around the circle, designed for rigging. This has a SWL of75Kg/m (between brackets). There is also a bar located in each bay of the Gallery. These bars are ratedat 180Kg UDL.

  • 8/17/2019 Royal Albert Hall Analisis

    8/30

     

    Royal Albert Hall Technical Specifications Page 8 of 30

    Lighting Specifications

    OverviewThe Royal Albert Hall Lighting Rig consists of a fixed rig of intelligent fixtures spread across 4 housetrusses over-stage, and an advance truss and circular truss located in the auditorium. There is also a fixedrig of generic and intelligent fixtures spread around the Circle rail, Organ Circles and Gallery level.

    Further InformationFurther specific information on the RAH rig both from a design and systems perspective, including gobos,colours, network protocols, circuit locations and patching can be obtained from the RAH LightingSpecification, which is available on the Royal Albert Hall website or through your Technical Show Manager,along with detailed PDF and WYSIWYG plans.

    Lighting Infrastructure

    Control & Networking

    The Hall’s lighting infrastructure primarily consists of CAT5 and fibre-optic runs throughout the auditoriumsupporting the ArtNet Protocol. There is also a second, independent network running MA Net2 at the maincontrol positions.These runs congregate in the Dimmer room, where they are distributed to each truss, terminating in a DMXNode, and to various auditorium locations as DMX via an ELC Node8 and DMX splitters in the Dimmerroom.

    Connections are located in appropriate places within the auditorium and can be connected either directly byEthernet or Opticonn (via in-house switch), or via an in-house Node8 DMX Input Node. Locations include:

    •  Rear Arena (ArtNet, MA Net2 & Opticonn)•  Loggia 18 (ArtNet, MA Net2 & Opticonn)•  G Stalls platform (ArtNet)

    •  Upstage Left & Right - back wall (ArtNet)•  RAH Control Room (ArtNet & MA Net2)

    •  Gallery Bay 1 (ArtNet and MA Net2)•  Gallery Tech Area - behind the organ

    (ArtNet)

    •  Gallery Bay 12 (ArtNet & MA Net2)•  Dimmer Room (ArtNet & MA Net2)•  Roof (ArtNet)

    Dimming & Hard Power

    All lighting circuits within the Auditorium and on the house trusses terminate in the Dimmer room in the formof a 16A Ceeform or Socapex patch bay.

    These circuits are located mostly around the circle rail, in most gallery bays, and on stage, in eitherSocapex or 16A Ceeform outlets.

    The RAH Dimmer room can supply 216 ways of dimming and 168 ways of hard power, of which there are125 dimmers and 130 ways of hard power allocated to the fixed rig. The remainder are patchable asrequired.

    House Trusses

    The house trusses are rigged with permanently installed Socapex, fed via reels in the roof, which is fixed toboth Socapex and individual 16A breakouts. Many of the circuits are used by the in house rig, with only afew remaining on each truss for production use. See the RAH Lighting Specification for more details.

    Houselights

    The auditorium houselights and working lights are controlled via Unison, with panels in various locations. Inmost circumstances the RAH will retain responsibility for their operation, including for show cues.

  • 8/17/2019 Royal Albert Hall Analisis

    9/30

  • 8/17/2019 Royal Albert Hall Analisis

    10/30

    Royal Albert Hall Technical Specifications

    Royal Albert Hall Technical Specifications Page 10 of 30

    Lighting Rig Plan

    Figure 4 - Lighting Rig Plan

    The Hall’s Lighting Rig plan is also available as a detailed PDF as well as a complete WYSIWYG file. Please ask your Technical ShowManager for more information or visit the technical area of the Royal Albert Hall website.

  • 8/17/2019 Royal Albert Hall Analisis

    11/30

     

    Royal Albert Hall Technical Specifications Page 11 of 30

    Power Specifications

    OverviewPlease note that the Hall utilises a TN-S earthing arrangement.Unless otherwise stated all sockets are Ceeform, 1Ø=Blue 3pole, 3Ø=Red 5pole.

    Figure 5 – Show Power Schematic

    Show & Tech Power Panels

    Under stage (QG – 400A TPN)Camlock* & Powerlock*

    125A 3Ø,2 x 63A 3Ø, 2 x 32A 3Ø6 x 63A 1Ø (2 x L1, 2 x L2, 2 x L3)6 x 32A 1Ø (2 x L1, 2 x L2, 2 x L3)4 x 13A RCD Protected.

    Arena (QK – 125A TPN)125A 3Ø, 63A 3Ø, 32A 3Ø125A 1Ø, 63A 1Ø, 32A 1Ø (ALL L2)3 x 16A 1Ø (1 x L1, 1 x L2, 1 x L3)

    Gallery East (QE – 400 TPN)Cam-lock, Power lock, up to 400A, 0.2 s125A 3Ø**, 63A 3Ø,32A 3Ø, 16A 3Ø32A 1Ø (L2), 16A 1Ø (L1)4 x 13A RCD Protected (L3)

    Gallery West (QD – 400A TPN)

    Camlock* & Powerlock*125A 3Ø, 63A 3Ø,32A 3Ø, 16A 3Ø

    32A 1Ø (L2) 16A 1Ø (L1)4 x 13A RCD Protected (L3)

    Under stage Sound (QH – 200A TPN)125A 3Ø, 63A 3Ø,32A 3Ø, 16A 3Ø,125A 1Ø, 63A 1Ø*** , 32A 1Ø (ALL L2)3 x 16A 1Ø (1 x L1, 1 x L2, 1 x L3)

    Gallery Sound (SL19 – 200A TPN)125A 3Ø, 63A 3Ø*** ,32A 3Ø, 16A 3Ø,125A 1Ø, 63A 1Ø,32A 1Ø, 16A 1Ø (ALL L2)

    * A range of fuses available including 125A,200A, 400A** Supplies RAH lighting rig when used*** Supplies Delta PA system when used

    FOH powerLoggia 18 - 63A 3Ø and 32A 3Ø supplies, for projectors etc.

    Rigging power32A 3Ø in Vom A & F (DSL & DSR) for temporary supplies during load in and out.

    SoundGallery (SL19)200A TPN

    Gallery EastLighting (QE)400A TPN

    Sub-stageLighting (QG)400A TPN

    Gallery WestLighting (QD) 400A TPN

    OB PowerDoor 11200A TPN

    Sound sub-stage (QH)200A TPN

    Sub-Arena(QK) 125A TPN

    RAH DimmersGallery East(QC) 300A TPN

    MAX 200A TPN MAX 700A TPN MAX 400ATPN

    MAX 200ATPN

  • 8/17/2019 Royal Albert Hall Analisis

    12/30

     

    Royal Albert Hall Technical Specifications Page 12 of 30

    Outdoor powerEast and West Car park - 2 x 63A 3Ø, 1 x 16A 1ØBoth located in ‘pop-up’ manhole covers, see Stage Door for access.

    Bus Power: Door 9 North (West Car Park, see plan below) – 1 x 32A 3Ø, 1 x 16A 1Ø

    Bus Power: Door 9 South (Outside Door 11) – 1 x 32A 3Ø, 1 x 16A 1Ø

    Figure 6 – West Car Park Power Plan

    Outside Broadcast PowerThe OB Power Room is located on basement level under door 10 and has a cable route direct tooutside Door 11 for powering OB vehicles parked here. There is also the ability to connect a back-up generator into this supply in case of power failure, with automatic switching.

    Main Incomer rated at 200A per θ 

    No. Rating Phase RCD RCD

    Bypass

    1 63A 1θ – L1 300mA 2 63A 1θ – L1 300mA 3 63A 1θ – L1 300mA 4 63A 1θ – L1 300mA 5 63A 1θ – L2 300mA 6 63A 1θ – L2 300mA 7 63A 1θ – L2 300mA 8 63A 1θ – L2 300mA 9 63A 1θ – L3 300mA 10 63A 1θ – L3 300mA

    11 63A 1θ – L3 300mA 12 63A 1θ – L3 300mA

    Figure 7 - OB Power Room Circuits

    No. Rating Phase RCD RCDBypass

    13 63A 3θ+E+N 300mA 14 63A 3θ+E+N 300mA 15 32A 3θ+E+N 30mA 16 32A(4x) 3θ+E+N 30mA 17 13A 30mA 18 125A 1θ – L1 300mA 19 125A 1θ – L2 300mA 20 16A 1θ – L1 30mA 21 32A 1θ – L2 30mA 22 32A 1θ – L3 30mA 23 125A 3θ+E+N 300mA

    24 63A 3θ+E+N 300mA 25 16A 3θ+E+N 30mA 26 125A 1θ – L3 300mA

  • 8/17/2019 Royal Albert Hall Analisis

    13/30

     

    Royal Albert Hall Technical Specifications Page 13 of 30

    Stage Specification 

    Stage & Arena Dimensions

    Figure 8 – Stage and Arena Dimensions

  • 8/17/2019 Royal Albert Hall Analisis

    14/30

     

    Royal Albert Hall Technical Specifications Page 14 of 30

    Stage information

    The Royal Albert Hall stage consists of four layers. The first layer is 24mm ply and an additional18mm layer on top. The next layer is made of 6mm ply and then the top layer is oil-tempered6.4mm hardboard. The Hall undertook a large project to replace the two top layers in April 2015.Following this major project it is essential that the stage is well maintained and that everything is

    done to avoid any permanent damage to the stage surface.

    The oil-tempered hardboard (the top layer) has a coat of multi-purpose black primer, a layer ofspectrum black and two layers of Bona Traffic glaze which protects the Stage.

    The stage has a weight load capacity of 5kn per SqM2

    All visiting production teams and performers must comply with the following:

    •  Orchestras must provide spike blocks for cellos and double bases.

    •  No items can be fixed to the stage without prior permission. This includes glue, nails and

    screws.

    •  Any holes created must be filled in at the cost of the event responsible for making them –

    this includes any materials and additional painting.

    •  Good quality/ low tack tape should be used on the stage and extra care should be taken

    when taking this up. The RAH technical team use Le Mark Mag Tape.

    •  Please make use of the cable traps and trays. The RAH technical team can advise on their

    locations.

    •  All steel deck, risers, chairs and other staging/set pieces must have end caps.

    •  Unless agreed in advance the stage must not be painted.

    •  No food or drink can be brought onto the stage. Water is permitted, so long as the container

    has a lid.

    •  Any damage caused to the stage must be made good immediately post the event. Any

    additional repair costs will be charged back to the promoter.

  • 8/17/2019 Royal Albert Hall Analisis

    15/30

     

    Royal Albert Hall Technical Specifications Page 15 of 30

    Lift information

    Lift A (Arena) also known as the MainLiftSWL 5,000kg dynamic/10,000kg staticUDL

    Lift floor dimensions – 6.63m x2.89mMain loading door – 2.36m H x2.48m WLong sided door – 2.36m H x 5.6mW

    This is the main lift for production

    load ins and load outs.

    Lift B (Broad) also known as theFront of Stage/Piano liftSWL  3,500kg dynamic/7,400kgstatic UDL

    This is generally used to extend the stage front, but often replaced with a steel-deck extension toenable the use of PA subs etc in the space underneath.

    Lift C (Contingency) also known as Small/Rear ArenaSWL 2,000kg dynamic/4,000kg static UDL

    This can be used by the house for chair and table removal etc whilst Lift A is being used byproduction.Lift floor dimensions - 2.69m x 2.87m

    Door 11 lift

    SWL 3,000kg UDL

    This is the only goods lift available to productions outside of the auditorium. Door 11 lift serves all

    floors, from the sub-basement (loading bay) to Gallery. For larger items a site visit is recommendedto view the routes to and from the lift on each level to ensure access is possible.Internal dimensions – H 2.98m (2.09m door) x W 1.8m x L 2.4m.

    Roof Service Hoist

    SWL 250kg

    For hauling equipment into the roof, there is a small hatch with variable speed 250kg chain hoistfrom ground floor level (O-stalls) to the lower walkway of the roof. Please discuss use of this withyour Technical Show Manager.Roof hatch opening: 0.63m x 0.63m

    STAGE

    ARENA

    Figure 9 – Auditorium

  • 8/17/2019 Royal Albert Hall Analisis

    16/30

     

    Royal Albert Hall Technical Specifications Page 16 of 30

    Comms System

    Overview

    The Hall is fitted with a full-duplex digital 4-channel Clear-Com Helixnet Partyline system withoutlets located in appropriate positions around the auditorium. The Helixnet system outputs 59V sois not compatible with other Clear-Com products. The Royal Albert Hall will provide six Helixnet 2-

    channel belt-packs and headsets and cabling free of charge. Additional sets (up to 16 total) maybe used at extra cost.

    Alongside the “House” ring, there is a separate “Visitor” XLR3 ring. A separate master-station canbe plugged in to this to enable touring companies to use their comms system instead.

    Figure 10 – Clear-Com Helixnet Belt-pack and Master Station

    Compatibility & Interfaces

    The master station and associated patching is located in the Blowing Chamber and is theresponsibility of your TSM.

    •  The base station has 2 outputs, each can power up to ten 2-channel belt-packs and ispatchable to meet requirements; the default setup is for one output to power gallery outletsand the second output powering the remaining tie lines.

    •  RTS or Clear-Com (analog 2-wire XLR3 or 4-wire RJ45) systems can interface with the

    Helixnet system via the interface module in the master station.•  Program feed can be fed into the master station.•  RAH Motorola Radios can interface with 1 channel of the Helixnet system.

    Plan

  • 8/17/2019 Royal Albert Hall Analisis

    17/30

     

    Royal Albert Hall Technical Specifications Page 17 of 30

    Sound Specification 

    Figure 11 – PA system at trim

    Delta Sound has been the preferred sound supplier to the Royal Albert Hall since 1993, providing

    audio services for thousands of shows in a variety of formats. During September 2013, theinstalled sound system underwent a complete upgrade and now offers promoters and eventorganisers a new level of audio excellence and flexibility.

    Delta Sound has a permanently installed speaker system in the venue suitable for a diverse arrayof concert settings. Other supporting items such as mixing consoles, stage monitor systems,microphones and backline are supplied on an event by event basis.

    ControlThe majority of live concerts and events utilise the stage in its normal position with a mixingconsole located either at the rear of the Arena seating or in Loggia Box 19 (see below). If your

    event is using the Arena as a performance space then the Loggia Box option is necessary. DeltaSound’s mixing desks are manufactured by DiGiCo and they stock the full range althoughalternative consoles can easily be supplied if required.

    Figure 12 – Rear Arena mix position Figure 13 – Loggia 19 mix position

  • 8/17/2019 Royal Albert Hall Analisis

    18/30

     

    Royal Albert Hall Technical Specifications Page 18 of 30

    PA Speaker System SpecificationPermanent PA system installation - comprising of 85 EM Acoustics HALO-Compact boxes in aLeft/ Centre/ Right configuration with a flown cardioid sub-bass unit alongside fills for the East andWest seats, upper choir and arena.

    Flown System (Main)Centre-hang comprising of:2 x EM Acoustics MSE-218 subwoofers in a cardioid arrangement12 x EM Acoustics HALO-Compact line array cabinetsLeft and Right main hangs comprising of:20 x EM Acoustics HALO-Compact line array cabinets per side

    Flown System (Fills)

    Left and Right outer hangs (circle end-fill) comprising of:5 x EM Acoustics HALO-Compact line array cabinets per sideLeft and Right outer hangs (stalls end-fill) comprising of:5 x EM Acoustics HALO-Compact line array cabinets per side (located on Truss 2)Left and Right rear hangs (choir-fill) comprising of:4 x EM Acoustics HALO-Compact line array cabinets per side (located on Truss 3)

    Ground System

    1 x EM Acoustics HALO-Compact line array cabinets per side (stalls end-fill)3 x EM Acoustics HALO-Compact line array cabinets on stage (arena front-fill)Additional subwoofers available depending on programme contentDelay snapshots available for fixed stage, 4’ stage or 8’ stage

    Gallery Delay System (optional, available on request)

    23 x Meyer Sound MPS-355 conventional cabinets (1 per gallery bay)Delay snapshots available for main system, cinema system or local use (T=0)

    A Meyer Sound Galileo 616 AES provides front-end system management and is available to oursystem technicians via a dedicated wireless network.

    Alternative Speaker ConfigurationsDelta Sound are also able to supply the following custom speaker packages for when the showconfiguration differs from the standard ‘end-on’ style:

    Cinematic configuration – For performances using a centre screen, alternative speaker hangs

    linked to the in-house infrastructure can be rigged to avoid visual obscuration.

    In-the-round configuration - The Royal Albert Hall also lends itself to an ‘in the round’ format, forindividual recitals or operatic performances (See Fig 6). We can supply a discrete speaker systemflown above a central cluster point that gives a natural focus in the arena.

    Non-auditorium venue spaces – We can supply the complete audio solution to spaces outside ofthe main hall including the Berry Brothers and Rudd No.3 Bar, The Gallery & Elgar Room in whichDelta Sound has a comprehensive Meyer Sound PA system permanently installed 

    If you would like any more information on Delta Sound audio services, please email

    [email protected] or call 020 8339 3800. Alternatively contact your designated RoyalAlbert Hall Event Manager or Technical Show Manager.

  • 8/17/2019 Royal Albert Hall Analisis

    19/30

     

    Royal Albert Hall Technical Specifications Page 19 of 30

    AV Solutions 

    SFL Group can provide a bespoke video solution for your event from a single central projectionscreen to a multi camera HD shoot. There is never a standard set up but to help you think throughoptions available to you here are some example screen locations.

    26’ x 15’ (16:9 ratio) Central Screen 21’ x 12’ (16:9 ratio) Side Screens

  • 8/17/2019 Royal Albert Hall Analisis

    20/30

     

    Royal Albert Hall Technical Specifications Page 20 of 30

    Projection & Screen Technologies

    SFL are stockists of Barco Projectors and by

    default this is what we would recommend. If forsome reason you would like to use anothermanufacturer then we can also quote you analternative solution.

    In terms of screen size this all depends on thecontent you are showing and the audience sizebut we would recommend a minimum screensize of 16’ wide. For a 16’ screen we wouldrecommend a 10,000 lumen projector. Below isa table giving you a few examples of screen andprojection configurations. These screens are allin the 16:9 wide screen ratio but we do alsosupply screens in 4:3 ratio.

    Screen Size Minimum Recommended Projection High Quality Projection

    16’ x 9’ Front /Rear

    1x Barco CLM R10+, 10,000 lumensDLP, SXGA+

    1x Barco HDX-W14, 14,000 lumens, Full HD

    21’ x 12’ Front /Rear

    2x Barco CLM R10+, 10,000 lumensDLP, SXGA+

    1x Barco HDX-W14, 14,000 lumens, Full HD

    26’ x 12’ Front /Rear

    1x Barco HDX-W14, 14,000 lumens, FullHD

    1x Barco HDX-W20, 20,000 lumens, Full HD

    18m x 7.6m(Cinema)

    2x Barco HDX-W20, 20,000 lumens, FullHD

    For events where front projection is required then wewould suggest some box holds to put the projectors in.Ideally GT22 but we can also use 2nd Tier 45/46.SFL can also provide a huge variety of screenconfigurations like this solution on the right. This is five12’ screens arranged in the round and projected fromthe gallery to provide a 360 degree screen solution forthe circle seats.

    Another screen option is plasmas; these could be usedas stage comfort screens or relay screens for the choirstalls just to ensure that every member of the audiencecan see a screen.

  • 8/17/2019 Royal Albert Hall Analisis

    21/30

     

    Royal Albert Hall Technical Specifications Page 21 of 30

    Camera & Graphics Switching Solutions

    SFL can also provide a complete camera solution for live to screenfootage or for recording & post production edit. As a standard weuse Sony broadcast spec cameras and Canon lens’. We alsoprovide various specials which may consist of elements such as Jib,Steady Cam, Track & Dolly.

    Our high definition solutions utilise Sony HXC-100 / HDC-1500 /HDC-2500 Cameras which are full HD interlaced.

    We have various HD-SDI portable production unit solutions whichcan take from 4 to 12 x SD/HD-SDI inputs along with a number ofcomputer inputs or playback sources.

    SFL can provide various imageprocessing solutions to run any

    number of projection or LED screens.SFL can also provide high end imageprocessing solutions for 4K video,screen blends, curved screens,projection mapping.

    SFL’s custom configured filmplayback solution can be used for filmwith live orchestra events along withnon DCI film premieres. If DCI isneeded then this is something thatcan also be provided.

    We also have stock of high res indoor LED solutions,various pixel pitch options are available depending onyour requirements.

    For more information or for a quote please contact uson the details below.

    SFL Group Main Number - 0118 969 0900

    SFL Group Email Address – [email protected] 

  • 8/17/2019 Royal Albert Hall Analisis

    22/30

     

    Royal Albert Hall Technical Specifications Page 22 of 30

    Health and Safety Specifications

    All information in this section is taken from the Hall’s Health and Safety policies which are availableto all incoming companies from your Event Manager or Technical Show Manager. This is notmeant as a comprehensive guide to health and safety, but as a reference to some of the moreimportant factors.

    Please also see:•  The Royal Albert Hall Event safety Guide •  The Royal Albert Hall Rigging Code of Practice•  The Royal Albert Hall Hard Hat Safe Working Practice•  The Royal Albert Hall Roof Access Code of Practice

    Hard Hat Safe Working Practice – OverviewThe Royal Albert Hall has identified the need for all personnel in specific areas to wear protectiveheadwear (Hard Hats) during the Load In and Load Out of events. This is due to the risk of headinjuries from working on and around Rigging/Lighting equipment. Movement of rigging or other

    automated equipment during a performance are subject to separate control measures and falloutside of this procedure.

    •  Whenever activity involving working on or around rigging, lighting or other technicalequipment is taking place then ALL personnel in the following locations are required towear a hard hat:

    o  Stageo  Choir Stallso  Arenao  All of the Stalls (Including all entrances and exits)o  In/On the Main Arena Lift including at sub-basement level.

    •  There are orange flashing beacons and illuminated signs in many locations around the

    auditorium and entrances.•  The beacons and signage will be activated or de-activated by the Hall’s Duty Technical

    Show Manager only. Production staff should contact the TSM to activate the beaconsystem and public address messaging.

    •  All RAH and Production management are to ensure this SWP is adhered to. Any persons,who are asked more than once to put a hard hat on, will be required to leave the buildingand not return that day.

    •  Suitable head protection is to be provided by Production or Contractor.•  A small quantity of Hard Hats will be provided to the Promoter and artists.•  Headwear is to comply with BS EN 397 or BS EN 12482.

    Personal Protective Equipment•  Anyone working at the Hall is expected to wear any PPE that has been assessed as being

    required for their tasks.•  Failure to do so will result in the individual being asked to cease work until the PPE is worn.

    Persistent refusal may result in the individual being asked to leave the building.•  All production company employees and contractors undertaking manual handling tasks or

    other tasks where there is a risk of foot injury are required to wear suitable safety footwear.In general, all shoes should at least enclose the toes.

    •  Work at height will be monitored closely to ensure that contractors use appropriate PPEsuch as harnesses and fall arrest equipment.

    Roof Access – OverviewThe roof areas of the Royal Albert Hall have been identified as high risk environments that requireeffective control. All non-RAH personnel wishing access to the Dome are to complete a TemporaryRoof Access Authorisation and receive a safety briefing and induction from a member of theTechnical Team. Please discuss with your TSM in advance if you believe roof access is required.

  • 8/17/2019 Royal Albert Hall Analisis

    23/30

     

    Royal Albert Hall Technical Specifications Page 23 of 30

    Emergency BeaconIt is the policy of the Hall that during amplified events, a beacon is placed within eye-shot of anymix positions. Should the beacon activate at any point, the sound engineer must cease all soundlevels emanating from the desk immediately and await further instruction. Emergency beacons willbe supplied by the Hall.

    Risk assessments

    Essentially there are five steps to risk assessment, which all those working in the Hall mustconsider:

    1. Look for hazards.2. Decide who might be affected and how.3. Evaluate the risks arising from the hazards and decide whether existing precautions are

    adequate or more should be done.4. Record your findings.5. Review your assessment from time to time and revise it if necessary.

    All routine activities relating to the staging of an event, from the load-in, the fit-up and the load outhave been assessed by appropriately trained Hall staff and are monitored/recorded by the showstaff. Where deemed necessary, safety precautions have been put in place and methods ofoperation improved to reduce hazard and risk.

    There may be occasions when unusual staging arrangements require activities not currentlyassessed. On such occasions promoters and production companies will be asked to assist theHall’s show staff in carrying out a risk assessment and implementing appropriate steps to ensuresafe working conditions.

    Everyone engaged in activities related to the staging of an event should ensure that their own

    personal safety and that of others is not compromised. Operatives should only undertake thosetasks that they are trained or skilled in, are physically capable of doing and that pose no risk orhazard to themselves or those around them.

    If required, further information regarding risk assessment is available from your Event Manager orTechnical Show Manager.

  • 8/17/2019 Royal Albert Hall Analisis

    24/30

     

    Royal Albert Hall Technical Specifications Page 24 of 30

    Sample Risk Assessment Form

    Job or Operation

    Hazards

    Personnel at risk

    Severity

    Initial Risk Rating LOW MED HIGH

    Controls

    Further Action Required / Notes

    Residual Risk Rating LOW MED HIGH

    Assessed by

    Action By

    Figure 14 - Sample Risk Assessment Form

  • 8/17/2019 Royal Albert Hall Analisis

    25/30

     

    Royal Albert Hall Technical Specifications Page 25 of 30

    Appendix 1 – Useful Measurements

    Load-In

    Door 11 lift dimensions – H 2.98m (2.09m door) x W 1.81m x L 2.41mMain lift (Lift A) dimensions – 6.63m x 2.89mMain loading door (Lift A) – 2.36 meters H x 2.48 meters WLong sided door (Lift A) – 2.36 meters H x 5.6 meters WRoof service hatch opening - 0.63m (2’) SquareCable route to sub-stage power cage – 20m

    Stage

    Stage width – 24m to F risers, 26.9m at widest point

    Stage depth (With or without orchestral risers) – 12.65 mStage height – 935mm (from arena floor)Front of stage opening (Between stalls) – 12.37mFront of stage opening with extension – 14.3mPiano lift (Lift B) dimensions – 9.67m x 1.8mBack of G-riser (drape line) – 30.5m

    Arena

    Width across arena (between B and E vomitories) – 17.58mDepth of arena (Stage front to C and D vomitories) – 26.23m

    Depth of arena (Stage lift front to C and D vomitories) – 24.43mSmall lift (Lift C) dimensions – 2.69m x 2.87mArena floor to Corona – 45m

    Other

    Back of stage to Slot motor position – 35m (height)Grand Tier Box 22 to rear of stage – 50 mCable route FOH Rear Arena to stage – 45m

  • 8/17/2019 Royal Albert Hall Analisis

    26/30

     

    Royal Albert Hall Technical Specifications Page 26 of 30

    Appendix 2 – Loading Reference

    Gallery Bar SWL – 180Kg (per bay)Circle Bar SWL – 75Kg per metre (between brackets)

    House Truss sub-hang capacity – 2 tons UDL per truss

    Lift A (Arena) - 5000kg dynamic or 10,000kg static.Lift B (Broad/Piano) - 3500kg dynamic or 7400kg staticLift C (Contingency/Rear Arena) - 2000kg dynamic or 4000kg staticDoor 11 Lift – 3000KgsRoof service hoist – 250kgsStage SWL - 5KN per m2 

    Appendix 3 – Standard Trim Heights

    House Trusses

    All heights from stage floor to bottom chord.

    Advance Truss – 15.6mTruss 1 – 12.8mTruss 2, 3 & 4 – 12.5m

    House PA

    All heights from the Arena floor to the speaker grid

    Main L&R - 17.5m

    Circle Outfill - 17.3mCentre - Approx. 16.2m (top of Halo C array is 15m, plus the sub at 1.1m and a little for the riggingbetween the 2)Boxes and Stalls Outfill (Truss 2) - 12.8mChoirs (Truss 3) - 12.5m

    Appendix 4 – Radio Mic Frequencies reserved by the Hall

    614.200MHz, 614.950MHz, 615.450MHz, 616.950MHz

  • 8/17/2019 Royal Albert Hall Analisis

    27/30

     

    Royal Albert Hall Technical Specifications Page 27 of 30

    Appendix 5 – Ancillary Patching

    Video & Camera PatchingThere is a comprehensive installation of audio and video patching which was installed inconjunction with the BBC to facilitate the Proms season, held at the Hall each year. This is

    available for use of incoming productions.

    All circuits terminate in a patch room beneath Door 11 on sub-basement level, which is a shortsimple cable route to OB vehicles outside.

    Location Quantity Facilities

    1 Gallery North 2 Camera triax (Lemo)3 Audio multiway (Mil 16-26) wired for 8 circuits21 Video circuits (BNC)8 SDV Circuits (BNC)

    2 16A Mains outlets (BS4343)1 13A Mains outlet (BS1363)

    2 Gallery South 1 Camera triax (Lemo)1 Audio multiway (Mil 16-26) wired for 8 circuits7 Video circuits (BNC)4 SDV Circuits (BNC)1 16A Mains outlets (BS4343)

    3 Grand tier box 3 (&2) 2 Camera triax (Lemo)3 Audio multiway (Mil 16-26) wired for 8 circuits21 Video circuits (BNC)8 SDV Circuits (BNC)2 16A Mains outlets (BS4343)

    1 13A Mains outlet (BS1363)4 Grand tier box 17 1 Camera triax (Lemo)

    1 Audio multiway (Mil 16-26) wired for 8 circuits7 Video circuits (BNC)4 SDV Circuits (BNC)1 16A Mains outlets (BS4343)

    5 Grand tier box 24 1 Camera triax (Lemo)2 Audio multiway (Mil 16-26) wired for 8 circuits14 Video circuits (BNC)4 SDV Circuits (BNC)1 16A Mains outlets (BS4343)

    1 13A Mains outlet (BS1363)6 Grand tier box 40 1 Camera triax (Lemo)2 Audio multiway (Mil 16-26) wired for 8 circuits14 Video circuits (BNC)4 SDV Circuits (BNC)1 16A Mains outlets (BS4343)1 13A Mains outlet (BS1363)

    7 Grand tier box 41 (&42) 1 Camera triax (Lemo)1 Audio multiway (Mil 16-26) wired for 8 circuits7 Video circuits (BNC)4 SDV Circuits (BNC)1 16A Mains outlets (BS4343)

    8 Loggia Box 6 1 Camera triax (Lemo)1 Audio multiway (Mil 16-26) wired for 8 circuits7 Video circuits (BNC)4 SDV Circuits (BNC)1 16A Mains outlets (BS4343)

  • 8/17/2019 Royal Albert Hall Analisis

    28/30

     

    Royal Albert Hall Technical Specifications Page 28 of 30

    9 Loggia box 18 1 Camera triax (Lemo)2 Audio multiway (Mil 16-26) wired for 8 circuits14 Video circuits (BNC)4 SDV Circuits (BNC)1 16A Mains outlets (BS4343)1 13A Mains outlet (BS1363)

    10 Loggia box 19 1 Camera triax (Lemo)

    2 Audio multiway (Mil 16-26) wired for 8 circuits14 Video circuits (BNC)4 SDV Circuits (BNC)1 16A Mains outlets (BS4343)1 13A Mains outlet (BS1363)

    11 Loggia box 27 1 Camera triax (Lemo)1 Audio multiway (Mil 16-26) wired for 8 circuits7 Video circuits (BNC)4 SDV Circuits (BNC)1 16A Mains outlets (BS4343)

    12 Loggia box 32 1 Camera triax (Lemo)

    1 Audio multiway (Mil 16-26) wired for 8 circuits7 Video circuits (BNC)4 SDV Circuits (BNC)1 16A Mains outlets (BS4343)

    13 Stage West 2 Camera triax (Lemo)2 Audio multiway (Mil 16-26) wired for 8 circuits14 Video circuits (BNC)8 SDV Circuits (BNC)2 16A Mains outlets (BS4343)

    14 Stage East 2 Camera triax (Lemo)2 Audio multiway (Mil 16-26) wired for 8 circuits14 Video circuits (BNC)

    8 SDV Circuits (BNC)2 16A Mains outlets (BS4343)

    15 Organ (Stage centre) 1 Camera triax (Lemo)1 Audio multiway (Mil 16-26) wired for 8 circuits7 Video circuits (BNC)4 SDV Circuits (BNC)1 16A Mains outlets (BS4343)

    16 Bullrun West 1 Camera triax (Lemo)2 Audio multiway (Mil 16-26) wired for 8 circuits14 Video circuits (BNC)4 SDV Circuits (BNC)1 16A Mains outlets (BS4343)

    1 13A Mains outlet (BS1363)17 Bullrun East 1 Camera triax (Lemo)

    2 Audio multiway (Mil 16-26) wired for 8 circuits14 Video circuits (BNC)4 SDV Circuits (BNC)1 16A Mains outlets (BS4343)1 13A Mains outlet (BS1363)

    18 Arena South, east 1 Camera triax (Lemo)1 Audio multiway (Mil 16-26) wired for 8 circuits7 Video circuits (BNC)4 SDV Circuits (BNC)

    1 16A Mains outlets (BS4343)19 Arena South, west 1 Camera triax (Lemo)1 Audio multiway (Mil 16-26) wired for 8 circuits7 Video circuits (BNC)4 SDV Circuits (BNC)

  • 8/17/2019 Royal Albert Hall Analisis

    29/30

     

    Royal Albert Hall Technical Specifications Page 29 of 30

    1 16A Mains outlets (BS4343)20 Arena South, south, west 1 Camera triax (Lemo)

    1 Audio multiway (Mil 16-26) wired for 8 circuits7 Video circuits (BNC)4 SDV Circuits (BNC)1 16A Mains outlets (BS4343)

    21 Arena North (east+west) 2 Camera triax (Lemo)3 Audio multiway (Mil 16-26) wired for 8 circuits21 Video circuits (BNC)8 SDV Circuits (BNC)2 16A Mains outlets (BS4343)1 13A Mains outlet (BS1363)

    22 Under Arena 2 Camera triax (Lemo)3 Audio multiway (Mil 16-26) wired for 8 circuits21 Video circuits (BNC)8 SDV Circuits (BNC)2 16A Mains outlets (BS4343)1 13A Mains outlet (BS1363)

  • 8/17/2019 Royal Albert Hall Analisis

    30/30

     

    Figure 15 - Video & Camera Patch Positions