14
ROTO-VENT for SERIES 401, 402, 403 storefront Installation Instructions Part NO. Y002 February 2013

ROTO-VENT for SERIES 401, 402, 403 storefront - Roto... · The height of the roto-vent is different between 401 and 402/403. This is due This is due The overall length of the roto-vent

Embed Size (px)

Citation preview

Page 1: ROTO-VENT for SERIES 401, 402, 403 storefront - Roto... · The height of the roto-vent is different between 401 and 402/403. This is due This is due The overall length of the roto-vent

 

ROTO-VENT for

SERIES 401, 402, 403 storefront

Installation Instructions

Part NO. Y002

February 2013

Page 2: ROTO-VENT for SERIES 401, 402, 403 storefront - Roto... · The height of the roto-vent is different between 401 and 402/403. This is due This is due The overall length of the roto-vent

and for longevity of the product.Steel screen material is used to ensure a tight fit of the screen inside the vent tubeinserted inside the PVC tube to prevent insect penetration to the interior. Stainlessclosed position, no PVC is visible from the interior. Screen cloth is rolled and facilitates operation of the vent, and is finished to match the system. When in themolded end cap with felt washers installed. A full length aluminum lift handleof the rotating ventilator are sealed against air and water infiltration by an injectionare 5 1/2" x 1" and the number of slots vary with the length of the tube. The endsThe rotating ventilator is fabricated from 3 1/2" PVC tubing. The ventilating slots

PAGES 3 & 4III APPLICATION BY SYSTEM

PAGE 13

PAGE 12

PAGES 7 - 11

PAGES 5 & 6

V

VI SIZING FORMULAS

PART PREPARATION & ATTACHMENT

PAGE 1

PAGE 2

SECTION

I

II

IV

VII TUBE REPLACEMENT

LOCATING & DRILLING TEMPLATE

PARTS IDENTIFICATION

GENERAL NOTES

exterior. 1. Bridging system thermal break with non-thermally broken metal flashing or lintels that are exposed to the inclusive, the list of examples below illustrates conditions under which condensation is likely to occur: Many current installation practices lead to an increase in the possibility of the formation of condensation. Though not all EFCO representative for information on EFCO's Thermal Analysis Services.professional is utilized to perform an analysis of the shop drawings to recommend the best installation methods. Please contacttemperature) are present. When the formation of excessive condensation is a concern, it is highly recommended that a design Condensation will form on any surface when unfavorable conditions (interior temperature and relative humidity and exteriorNOTE: Please reference EFCO's "Understanding Condensation" brochure which can be obtained through your EFCO representative.

Minimizing Condensation

3. Interior relative humidity levels not maintained at recommended levels, see EFCO's "Understanding 2. System exposure to cold air cavities.

4. Inadequate separation between system and surrounding condition at perimeter. Condensation" brochure.

involved. 5. Product combinations during the shop drawing stage that result in bridging thermal breaks of one or all products

Page 3: ROTO-VENT for SERIES 401, 402, 403 storefront - Roto... · The height of the roto-vent is different between 401 and 402/403. This is due This is due The overall length of the roto-vent

}{

PARTS INDENTIFICATION

#9959

SILL

#9953

RETAINER

USED AT LOWER SHEAR BLOCKPACKAGE INCLUDES (1) STT7

(EXT. 9955)

STD3S100

STD3

K159

SHEAR BLOCK

[2]

[2] #9952

MEETING RAIL

[1]

[1]

[1]

(43-019, 43-020, 43-021)700-10

VENT TUBE ASSEMBLY

SECTION II -

[2]

[1]

& S-403)(S-402

H190(60-229)

(S-401)H162

BLOCKSSETTING

PILE WEATHERINGWF08(60-232)

PILE WEATHERINGWW78(60-233)

#8 x 3/4" P.H. TEK

STK0

RETAINER FASTENERS

S108

#8x1" HEX WASHER HEAD S.M.S.

JAMB FASTENERS(SCREW SPLINE)

Page 4: ROTO-VENT for SERIES 401, 402, 403 storefront - Roto... · The height of the roto-vent is different between 401 and 402/403. This is due This is due The overall length of the roto-vent

is similar.Screw splineattachment shown.Shear block

WEEP

APPLICATION BY SYSTEM

S401 APPLICATION

PAGE 3

SECTION III -

S100S100

S100S100

STK0STD3

STT7

H16

2

9959

9121

(9955)K159

9953(9955)K159

9952

91299129

8" S

IGH

TLI

NE

3/4"

Page 5: ROTO-VENT for SERIES 401, 402, 403 storefront - Roto... · The height of the roto-vent is different between 401 and 402/403. This is due This is due The overall length of the roto-vent

9221

WEEP

Screw splineis similar.

S402/403 APPLICATIONShear blockattachment shown.

SECTION III - APPLICATION BY SYSTEMPAGE 4

S100S100

S100S100

STK0STD3

STT79959

9314

H190

(9955)K159

(9955)K159

9952

92299229

9953

8 7/

16"

SIG

HT

LIN

E

1 3/

16"

Page 6: ROTO-VENT for SERIES 401, 402, 403 storefront - Roto... · The height of the roto-vent is different between 401 and 402/403. This is due This is due The overall length of the roto-vent

(5) PLACES

TEMPLATESECTION IV - LOCATING & DRILLING

.172 DIA. (#18 DRILL)SCREW SPLINE HOLES

SE

T E

DG

ES

OF

TE

MP

LAT

E F

LUS

H W

ITH

SID

ES

OF

VE

RT

ICA

LS

CUT OUT AND USE FOR LOCATING HOLES

SHEAR BLOCKOR

SCREW SPLINE

SHEAR BLOCK HOLES

(4) PLACES.136 DIA. (#29 DRILL)SHEAR BLOCK HOLES

1.508

1.047

.250

.250

5.500

1.070

.8752.750.875

9959

9952

K159

9129

9229

PAGE 5

INT

ER

IOR

- 4

01 S

YS

TE

M

EX

TE

RIO

R -

402

/403

SY

ST

EM

S

Page 7: ROTO-VENT for SERIES 401, 402, 403 storefront - Roto... · The height of the roto-vent is different between 401 and 402/403. This is due This is due The overall length of the roto-vent

(4) PLACES.136 DIA. (#29 DRILL)SHEAR BLOCK HOLES

(5) PLACES

SECTION IV -TEMPLATELOCATING & DRILLING

.172 DIA. (#18 DRILL)SCREW SPLINE HOLES

SE

T E

DG

ES

OF

TE

MP

LAT

E F

LUS

H W

ITH

SID

ES

OF

VE

RT

ICA

LS

CUT OUT AND USE FOR LOCATING HOLES

SHEAR BLOCKOR

SCREW SPLINE

SHEAR BLOCK HOLES

1.508

1.047

.250

.250

5.500

1.070

.875 2.750 .875

9959

9952

K159

9129

9229

PAGE 6

EX

TE

RIO

R -

402

/403

SY

ST

EM

S

INT

ER

IOR

- 4

01 S

YS

TE

M

Page 8: ROTO-VENT for SERIES 401, 402, 403 storefront - Roto... · The height of the roto-vent is different between 401 and 402/403. This is due This is due The overall length of the roto-vent

at 1/4 points.1/4" dia. weep holes

to protect the exposed surface of the sill member when drillingthe weep holes.

STEP 2) Drill 1/4" diameter weep holes flush with the interior surface ofthe sill member. Locate weep holes at quarter points. Take care

STEP 1)during installation.Notch the ends of the tube retainer to clear the shear block

EXPOSED

INTERIOR

ATTACHMENTSECTION V - PART PREPARATION &

1.313

9953

9959

EXTERIOR

PAGE 7

Page 9: ROTO-VENT for SERIES 401, 402, 403 storefront - Roto... · The height of the roto-vent is different between 401 and 402/403. This is due This is due The overall length of the roto-vent

of the roto-vent sill member’s location.for all pocket fillers is 6 1/8". Locate the pocket filler 1" from the bottomSelect the correct pocket filler for the system being used. The cut lengthSTEP 3)

CU

T L

EN

GT

H6

1/8"

PO

CK

ET

FIL

LER

TH

E G

LAS

S S

TO

PS

8 7/

16"

SIG

HT

LIN

E IN

CLU

DIN

G

CU

T L

EN

GT

H6

1/8"

PO

CK

ET

FIL

LER

TH

E G

LAS

S S

TO

PS

8 7/

16"

SIG

HT

LIN

E IN

CLU

DIN

G

CU

T L

EN

GT

H6

1/8"

PO

CK

ET

FIL

LER

CONT.ATTACHMENT

PAGE 8

1 5/16"

1"

TH

E G

LAS

S S

TO

PS

8.00

0" S

IGH

TLI

NE

INC

LUD

ING7/8"

1"

1 5/16"

FILLER FOR401 SYSTEM

#9151 POCKET

1"

#9251 POCKETFILLER FOR402 SYSTEM

SECTION V -

#9351 POCKETFILLER FOR403 SYSTEM

PART PREPARATION &

Page 10: ROTO-VENT for SERIES 401, 402, 403 storefront - Roto... · The height of the roto-vent is different between 401 and 402/403. This is due This is due The overall length of the roto-vent

after the unit is installed.

STEP 4) Pre-drill the meeting rail with a #18 drill (.170 dia.) 2" from the ends and16" on center. The TEK screws (STK0) will be used to attach the tube retainer

(STK0)

CONT.

SECTION V -ATTACHMENTPART PREPARATION &

.170 DIA. THRU DRILL

ON CENTERS

MEETING RAIL(9952)

EXTERIOR SIDE

2" FROM END & 16"

(9953)RETAINER

#8x1" P.H.TEK

PAGE 9

Page 11: ROTO-VENT for SERIES 401, 402, 403 storefront - Roto... · The height of the roto-vent is different between 401 and 402/403. This is due This is due The overall length of the roto-vent

SHEAR BLOCK ATTACHMENT METHOD

7/8"

STEP 7)holes 7/8" from the inside surface using a #18 drill (.170 dia.).Drill through the sill member accurately at 1" from the ends and locating the

STEP 6) Drill through the meeting rail accurately at 1" from the ends and in the locatinggroove using a #18 drill (.170 dia.).

STEP 5) Determine the location of the roto-vent. Mark the layout of the shear blockattachment screws using the template provided with these instructions.

CONT.ATTACHMENTPART PREPARATION &SECTION V -

1.000 +.000-.010

.172 DIA. DRILL(3 HOLES)

PAGE 10

S100

(4 HOLES).136 (NO. 29 DRILL)

S100

the ends of the roto-ventUse a butyl sealant at both

meeting rail and sill memberas shown in the shaded areas.

Page 12: ROTO-VENT for SERIES 401, 402, 403 storefront - Roto... · The height of the roto-vent is different between 401 and 402/403. This is due This is due The overall length of the roto-vent

SCREW SPLINE ATTACHMENT METHOD

STEP 5)

STEP 6)

Determine the location of the roto-vent. Mark the layout of the screw splineattachment screws using the template provided with these instructions.

Drill through the open back verticals with a #18 drill (.170 dia.).

Use a butyl sealant at boththe ends of the roto-ventmeeting rail and sill memberas shown in the shaded areas.

CONT.ATTACHMENTPART PREPARATION &SECTION V -

PAGE 11

#18 drill thru (.170 dia.)clear hole forS-100 (#8 x 1" SL.HW.SMS.)(5 HOLES)

Page 13: ROTO-VENT for SERIES 401, 402, 403 storefront - Roto... · The height of the roto-vent is different between 401 and 402/403. This is due This is due The overall length of the roto-vent

]

INTERIOR SIDE

#3 and #4 for the correct dimensions per system.to the different heights of the glass stops. Refer to the illustration below and pagesThe height of the roto-vent is different between 401 and 402/403. This is dueThe overall length of the roto-vent assembly equals daylite opening, in all systems.

PAGE 12

DAYLITEOPENING

EXTERIOR SIDE

[401 STSTEM]

8" INCLUDINGGLASS STOPS

LENGTH =

8.438"

GLASSSTOPS

SYSTEMS402/403

INCLUDING

DAYLITEOPENING

VENT

LENGTH = MINUS .188" (3/16")

SECTION VI - SIZING FORMULAS

Page 14: ROTO-VENT for SERIES 401, 402, 403 storefront - Roto... · The height of the roto-vent is different between 401 and 402/403. This is due This is due The overall length of the roto-vent

(STK0)

Order the replacement tube completely fabricated from the factory.The length of the replacement tube is daylite opening minus 3/16".

Follow steps 1 through 4 below for roto-vent tube replacement.

EXTERIOR SIDE

Remove the retainer screws.STEP 2

PAGE 13

Slide tube toward the interiorto remove for replacement.

STEP 4

TUBE REPLACEMENT

STEP 1Remove the glazing gasket

(#9953)

STEP 3Remove tube retainer

and the interior glass stop.

SECTION VII -