ROTINA 380/380 R Benchtop Centrifuges classic/cooled

ROTINA 380/380 R Benchtop Centrifuges classic/cooled 380.pdf · ROTINA 380 Cat. No. 1701 Efficiency and safety are key requisites in today’s laboratories – whether for research

Embed Size (px)

Citation preview

ROTINA 380/380 R Benchtop Centrifugesclassic/cooled

2

ROTINA 380

Cat. No. 1701

Efficiency and safety are key requisites in today’s laboratories – whether for research or routine tasks.

Wherever centrifuges are incorporated to working processes, they need to deliver good separation results quickly and safely.

The ROTINA 380 and 380 R centrifuge models are ideally equipped to take on these challenges. Their high performance and advanced features set standards among the benchtop centrifuges in their class.

Samples with capacities of up to 4 x 290 ml can be processed in these high-performance centrifuges with a max. RCF of 4,863. Should higher speeds be required, angle rotors with a max. RCF of 16.504 for 50 ml tubes are available.

Accessories with bio-containment protect users from aerosols while ensuring optimal safety, for instance, while centrifuging infectious samples.

PERFORMANCE

● High capacity · max. 4 x 290 ml · max. 36 x 15 ml● High RCF · up to 16.504 for 50 ml tubes and 94 ml tubes · up to 24,400 for reaction tubes

DESIGN

● Metal housing● Stainless steel centrifuging chamber ● Viewing port in the lid

USER-FRIENDLINESS

● Powered lid locking● Ergonomic control and information panel● Easy rotor changing● 98 program storage spaces

COOLING (ROTINA 380 R)

● Infinitely variable adjustment from - 20 °C to + 40 °C (or - 4 °F to + 104 °F)● Stand-by cooling

SAFETY

● Lid locking and holding● Emergency lid lock release● Lid dropping protection ● Automatic rotor recognition● Imbalance switch-off● Motor overheating protection● Chamber overheating protection (ROTINA 380 R)

ROTINA 380/380 R

3

ROTINA 380 R control panel (C control panel)

ROTINA 380 R cooled

Cat. No. 1706

OPERATION AND CONTROL

With the convenient C control panel, even the most challenging centrifugation programs can easily be keyed in, stored and accessed as required.

98 program memory positions are available. Additional program position “PREC” (PRE-COOLING) is reserved for the pre-cooling program.

Parameter selection is done via the use of symbol keys. Values are set with the control knob, and recorded by pressing the Start key.

9 braking and acceleration ramps, unbraked run-down, or a cut-off speed can be selected. Ramp 9 represents the shortest braking and acceleration time.

The temperature in the ROTINA 380 R refrigerat-ed centrifuge can be set in either Celsius (°C) or Fahrenheit (°F) degrees. The temperature range is between - 20 °C and + 40 °C or between- 4 °F and + 104 °F.

DIGITAL DISPLAY AND CONTROL PANEL

KEYBOARD

START Start centrifugation run / short centrifuging runs / save entries and changes

Start pre-cooling program PREC

STOP Manually end centrifugation run /OPEN Open lid

PARAMETER INPUT

PROG Input / recall program number 98 programs can be stored

T/°C Input temperature in increments of 1 from - 20 °C to + 40 °C or - 4 °F to + 104 °F (ROTINA 380 R)

Input of acceleration levels 1 – 9 or in min : sec Input of braking levels 1 – 9 or in min : sec Input brake force cut-off

RCF Input relative centrifugal force (RCF) in increments of 1 Enter centrifuging radius (RAD) in mm

RPM Input speed in increments of 10

TIME Input length of centrifugation (max. 99 h : 59 min : 59 sec) or continuous operation

4

ROTORS AND ACCESSORIES

Swing-out rotor 4-place

) 90°n = 5,000 min -1 max. RCF 4,863

Cat. No. 1754

Some accessories with bio- containment4)

Some accessories with bio- containment4)

P.6-7

P.8-11

P.14

P.12-13

P.14

Quick overview of rotors and suitable accessories. The figures highlighted under the arrows refer to the pages where technical and ordering details are listed.

Swing-out rotor 4-place

) 90°n = 4,000 min -1 max. RCF 3,095

Cat. No. 1798

Swing-out rotor 10-place

) 45°n = 4,000 min -1 max. RCF 2,916

Cat. No. 1717

Swing-out rotor 6-place

) 90°n = 4,000 min -1 max. RCF 2,808

Cat. No. 1726

Swing-out rotor 2-place

) 90°n = 4,000 min -1 max. RCF 2,397

Cat. No. 1760

4) Tested by the TÜV in conformity with DIN EN 61010, section 2-020.

1.5/2 ml 3 – 250 ml 1.6 – 10 ml 1.1 – 10 ml 15 – 50 ml 12 – 50 ml 10 – 94 ml 175– 290 ml

1.5/2 ml 3 – 250 ml 1.6 – 10 ml 1.1 – 10 ml 15 – 50 ml 12 – 50 ml 10 ml 250/290 ml cyto

15/50 ml

1.5/2 ml 1 – 50 ml 1.6 – 10 ml 1.1 – 10 ml 15 ml 30 ml cyto

Angle rotor 6-place

) 45°

380 R:n = 11,000 min -1

max. RCF 16,369

380:n = 10,000 min -1

max. RCF 13,528

Cat. No. 1720

1.5/2 ml 15 – 94 ml 8.5 – 10 ml 7.5 – 10 ml 15/50 ml 10 – 94 ml

P.15

MTP CP DWP MS QP

microtitre culture deep well Micronic filter Microtest plate PCR plate, PCR plate plate plate system plate (Terasaki) 96 wells strips

5

ROTORS AND ACCESSORIES

Angle rotor 6-place

) 45°

380 R:n = 11,000 min -1

max. RCF 16,504

380:n = 10,000 min -1

max. RCF 13,640

Cat. No. 1792

Angle rotor 30-place

) 45°n = 15,000 min -1 max. RCF 24,400

Cat. No. 1789-A

with bio- containment4)

with bio- containment4)

P.16

P.17

P.17

P.18

P.18

Angle rotor 8-place

) 45°n = 4,500 min -1 max. RCF 3,305

Cat. No. 1721

Drum rotor 6-place

n = 15,000 min -1 max. RCF 18,866

Cat. No. 1711

Cyto rotor 8-place

n = 4,000 min -1 max. RCF 2,415

Cat. No. 1748

Detailed information on our comprehensive range of cyto accessories is provided in a separate brochure. We will be pleased to send one to you on request.

5/15 ml 1.6 – 10 ml 1.1 – 10 ml 12 ml 15/50 ml 12/50 ml 50 ml

1.5/2 ml 15 – 94 ml 8.5 – 10 ml 7.5 – 10 ml 15/50 ml 10 – 94 ml

0.2– 2.0 ml

0.2– 2.0 ml

Additional tubes e.g. stool tubes or spin columns on request.

6

ROTORS AND ACCESSORIES

1) Lowest attainable temperature in precooled refrigerated centrifuges at max. speed. Lower temperatures can be reached by reducing the speed.2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers. The max. RCF for glass tubes annotated with footnote 2) is 4,000.3) When using these tubes, carrier 1752 cannot be closed with lid 1751.

) 90°

n = 5,000 min-1

max. RCF 4,863

Cat. No. (without carriers) 1754

Swing-out rotor, 4-place

illustrated with carriers 1752 and lids 1751

with bio-containment4)

capacity in ml 1.5 2.0 3 4 5 6 7 9 10 15 20 25 45 50 75

Ø x L in mm 11 x 38 10 x 60 12 x 60 12 x 75 12 x 82 12 x 100 14 x 100 17 x 70 17 x 100 21 x 100 24 x 100 31 x 100 34 x 100 35 x 105

Cat. No. 2078 0536 - 05532) 05012) 05782) 05002) 2079 05182) - 05192) - 05212) 0548

carrierCat. No. 1752

Cat. No. 1761 1761 1762-A 1763-A 1764 1765

boring Ø x L in mm 11.2 x 39.5 11.2 x 39.5 12.5 x 56 17.5 x 62 25.5 x 81 35.5 x 81

tubes per rotor 144 72 96 52 24 12

max. RCF2) upper/lower 3,494 / 4,779 4,779 4,668

radius in mm upper/lower 125 / 171 171 167

run-up in sec 42

run-down in sec, braked 27

temperature in °C1) 0

lid with bio-containment4)

Cat. No. 1751

capacity in ml 94 100 100 250 1.1–1.4 2.6–3.4 2.7–3 4–5.5 4.5–5 4.9 7.5–8.5 9–10 10 1.6–5 4–7

Ø x L in mm 38 x 102 40 x 115 44 x 100 65 x 115 8 x 66 13 x 65 11 x 66 15 x 75 11 x 92 13 x 90 15 x 92 16 x 92 15 x 102 13 x 75 13 x 100

Cat. No. 0549 05232) 05262) 05302) blood collection/urine tubes

carrierCat. No. 1752

Cat. No. 1777 1767 1766 1768 1781 1783-A 1762-A 1763-A 1762-A 1783-A 1763-A 1783-A

boring Ø x L in mm 38.5 x 80 41 x 97 45 x 87 66x104.5 9 x 49 13.5 x 54 12.5 x 56 17.5 x 62 12.5 x 56 13.5 x 54 17.5 x 62 13.5 x 54

tubes per rotor 8 4 4 4 96 64 96 52 96 64 52 64

max. RCF 2) 4,807 4,640 4,640 4,668

radius in mm 172 166 166 167

run-up in sec 42

run-down in sec, braked 27

temperature in °C1) 0

lid with bio-containment4)

Cat. No. 1751

7

capacity in ml 4–7 8 8,5–10 15 50 12 25 30 50 50 10 14 30 50 85

Ø x L in mm 16 x 75 16 x 125 16 x 100 17 x 120 29 x 115 17 x 100 25 x 90 25 x 110 29 x 115 29 x 115 16 x 80 16,5 x 106 26 x 95 29 x 107 38 x 106

Cat. No. blood/urine tubes 0509 0513 - 0513 - 0545 0546 0547

carrierCat. No. 1752

10) + E 2110-A

Cat. No. 1763-A 1763-A 1771-A 1772-A 1773 1779 1774-A 1763-A 1775 1774-A 1777

boring Ø x L in mm 17.5 x 62 17.5 x 62 17 x 84 30 x 84 17 x 78 26.5 x 72 30 x 80 17.5 x 62 26.5 x 70 30 x 80 38.5 x 80

tubes per rotor 52 12 52 36 16 36 20 16 52 24 16 8

max. RCF 2) 4,668 4,863 4,863 4,696 4,528 4,752 4,668 4,807 4,752 4,807

radius in mm 167 174 174 168 162 170 167 172 170 172

run-up in sec 42

run-down in sec, braked 27

temperature in °C1) 0

capacity in ml 94 175 175 200 225 250 290

Ø x L in mm 38 x 102 61 x 118 62 x 144 60 x 130 61 x 137 61 x 122 62 x 137

Cat. No. 0538 5) Falcon® Nalgene® Nunc® Falcon® 51276) -6)

carrierCat. No. 1752

3) 3)

Cat. No. 1777 1782 1778 1778 1782 1769

boring Ø x L in mm 38.5 x 80 62 x111 62 x111 62 x111 62 x111 62 x100

tubes per rotor 8 4

max. RCF 2) 4,807 4,863

radius in mm 172 174

run-up in sec 42

run-down in sec, braked 27

temperature in °C1) 0

ROTORS AND ACCESSORIES

4) Tested by the TÜV in conformity with DIN EN 61010, section 2-020. 5) The screw cap for tube No. 0538 is available with Cat. No. 0539. Dimensions with cap 38 x 106 mm. 6) At temperatures of over + 40 °C and / or when not filled to capacity, bottles may warp during centrifugation. 10) Carrier must be loaded as illustrated.

illustrated with carriers 1752 and lids 1751

with bio-containment4)

Swing-out rotor Cat. No. (without carriers) 1754

lid with bio-containment 4)

Cat. No. 1751

lid with bio-containment 4)

Cat. No. 1751

8

(neues)Foto von Reduzierung und Röhrchen?

ROTORS AND ACCESSORIES

illustrated with carriers 5051 and lids 5053

) 90°

n = 4,000 min-1

max. RCF 3,095

Cat. No. (without carriers) 1798

Swing-out rotor, 4-place

capacity in ml 1.5/2.0 3 5 6 7 9 15 25 50 100 100

Ø x L in mm 11 x 38 10 x 60 12 x 75 12 x 82 12 x 100 14 x 100 17 x 100 24 x 100 34 x 100 40 x 115 44 x 100

Cat. No. - 2078/0536 - 0553 2) 0501 2) 0578 2) 0500 2) 0518 2) 0519 2) 05212) 0523 2) 0526 2)

carrierCat. No. 5051

Cat. No. 5257 5281 5267 5227 52477) 5264 52487) 5242 5243 5249 5262

boring Ø x L in mm 12.5 x 42 11.5 x 50 11 x 44 12.5 x 42 12.5 x 86 16 x 50 17.5 x 86 26 x 86 36 x 86 42 x 86 45.5 x 86

tubes per rotor 160 64 80 80 80 48 48 20 8 4

max. RCF 2) upper/ lower 1,950/2,826 2,826 2,737 2,773 2,755 2,773 2,755

radius in mm upper/ lower 109/158 158 153 155 154 155 154

run-up in sec 24

run-down in sec, braked 17

temperature in °C1) -8

lid Cat. No. 5053

capacity in ml 1.1–1.4 2.6–3.4 2.7–3 4–5.5 4.5–5 4.9 7.5–8.5 9–10 10 1.6–5 4–7 4–7 8.5–10

Ø x L in mm 8 x 66 13 x 65 11 x 66 15 x 75 11 x 92 13 x 90 15 x 92 16 x 92 15 x 102 13 x 75 13 x 100 16 x 75 16 x 100

Cat. No. blood collection/urine tubes

carrierCat. No. 5051

3)

Cat. No. 5267 5268 5227 5264 5227 5268 5264 5258 5268 5264 5248

boring Ø x L in mm 11 x 44 13.5 x 52 12.5 x 42 16 x 50 12.5 x 42 13.5 x 52 16 x 50 17.6 x 86 13.5 x 52 16 x 50 17.5 x 86

tubes per rotor 80 48 80 48 80 48 44 48

max. RCF 2) 2,737 2,808 2,773 2,808 2,773 2,755 2,808 2,773 2,755

radius in mm 153 157 155 157 155 154 157 155 154

run-up in sec 24

run-down in sec, braked 17

temperature in °C1) - 8

lid Cat. No. 5053

1) Lowest attainable temperature in precooled refrigerated centrifuges at max. speed. Lower temperatures can be reached by reducing the speed. 2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used

should be verified with the individual manufacturers. The max. RCF for glass tubes annotated with footnote 2) is 4,000. 3) When using these tubes, carrier 5051 resp. 5092 cannot be closed with lid 5053 resp. 5093.

9

ROTORS AND ACCESSORIES

capacity in ml 15 30 50 12 30 50 two-tier frame for cyto accessoriesØ x L in mm 17 x 120 25 x 110 29 x 115 17 x 100 25 x 110 29 x 115

Cat. No. 0509 - 0513 - - - cyto chambers 8)

carrierCat. No. 5051

3) 3) 3) 3) 3)

+ 2 x 6316

Cat. No. 6306 5266 5259 6306 5266 5243 5280

boring Ø x L in mm 17 x 90 26 x 86 30 x 86 17 x 90 26 x 86 36 x 86 -

tubes per rotor 28 20 8 28 20 8 8

max. RCF 2) upper/ lower 2,898 2,755 2,826 2,898 2,755 2,755 1,735 / 2,737

radius in mm upper/ lower 162 154 158 162 154 154 97/ 153

run-up in sec 24

run-down in sec, braked 17

temperature in °C1) -8

lid Cat. No. 5053

7) With Cat. No. 5247-91 or 5248-91 these adapters can also be ordered with a decanting aid. 8) Please ask for our detailed cyto brochure.

illustrated with carriers 5051 and lids 5053

Swing-out rotor Cat. No. (without carriers) 1798

10

ROTORS AND ACCESSORIES

Swing-out rotor Cat. No. (without carriers) 1798

illustrated with carriers 5092 and lids 5093

with bio-containment4)

capacity in ml 5 6 7 10 15 25 50 100 100 250

Ø x L in mm 12 x 75 12 x 82 12 x 100 17 x 70 17 x 100 24 x 100 34 x 100 44 x 100 40 x 115 65 x 115

Cat. No. 05532) 0501 2) 0578 2) 2079 0518 2) 0519 2) 0521 2) 0526 2) 0523 2) 0530 2)

carrierCat. No. 5092

Cat. No. 5128 5120 5136 5122 5124 5125 5126 1791

boring Ø x L in mm 12.8 x 45 12.8 x 82 17.5 x 60.7 25.5 x 82 35.5 x 85 45.5 x 85 42 x 85 66 x 103

tubes per rotor 48 32 16 4 4

max. RCF 2) 3,005 2,952 2,898 2,952 3,095

radius in mm 168 165 162 165 173

run-up in sec 24

run-down in sec, braked 17

temperature in °C1) -8

lid with bio-containment4)

Cat. No. 5093

capacity in ml 15 30 50 12 25 30 50 10 250 290

Ø x L in mm 17 x 120 25 x 110 29 x 115 17 x 100 25 x 90 25 x 110 29 x 115 16 x 80 61 x 122 62 x 137

Cat. No. 0509 - 0513 - - - 51276) -6)

carrierCat. No. 5092

3)

Cat. No. 51299) 5122 5123 5121 5134 5122 5135 5136 6319

boring Ø x L in mm 17 x 85 25.5x 82 30 x 85 17.5 x 82 26 x 73 25.5 x 82 30 x 99 17.5 x 60.7 66 x 103

tubes per rotor 28 16 8 28 12 16 8 32 4

max. RCF 2) 3,095 2,898 3,095 3,005 2,826 2,898 3,023 2,952 3,095

radius in mm 173 162 173 168 158 162 169 165 173

run-up in sec 24

run-down in sec, braked 17

temperature in °C1) -8

lid with bio-containment4)

Cat. No. 5093

1) Lowest attainable temperature in precooled refrigerated centrifuges at max. speed. Lower temperatures can be reached by reducing the speed. 2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used

should be verified with the individual manufacturers. The max. RCF for glass tubes annotated with footnote 2) is 4,000. 3) When using these tubes, carrier 5092 cannot be closed with lid 5093.

11

ROTORS AND ACCESSORIES

lid with bio-containment4)

Cat. No. 5093

4) Tested by the TÜV in conformity with DIN EN 61010, section 2-020. 6) At temperatures of over + 40 °C and / or when not filled to capacity, bottles may warp during centrifugation. 9) Please remove the inserts.

Swing-out rotor Cat. No. (without carriers) 1798

illustrated with carriers 5092 and lids 5093

with bio-containment4)

capacity in ml 1.1–1.4 2.6–3.4 2.7–3 4–5.5 4.5–5 4.9 7.5–8.5 9–10 10 1.6–5 4–7 4–7

Ø x L in mm 8 x 66 13 x 65 11 x 66 15 x 75 11 x 92 13 x 90 15 x 92 16 x 92 15 x 102 13 x 75 16 x 75 16 x 75

Cat. No. blood collection/urine tube

carrierCat. No. 5092

Cat. No. 5138 5136 5120 5137 5136 5138 5136 5121-93

boring Ø x L in mm 12.8 x 54.5 17.5 x 60.7 12.8 x 82 13.5 x 60.7 17.5 x 60.7 12.8 x 54.5 17.5 x 60.7 17.5 x 52

tubes per rotor 48 32 48 32 32 48 32 28

max. RCF 2) 2,540 2,952 3,005 2,952 2,952 2,540 2,952 3,005

radius in mm 142 165 168 165 165 142 165 168

run-up in sec 24

run-down in sec, braked 17

temperature in °C1) -8

capacity in ml 4–7 8 8.5–10

Ø x L in mm 13 x 100 16 x 125 16 x 100

Cat. No. blood/urine tubes

carrierCat. No. 5092

3)

Cat. No. 5120 51219) 5136

boring Ø x L in mm 12.8 x 82 17.5 x 82 17.5 x 60.7

tubes per rotor 48 28 32

max. RCF 2) 3,005 3,059 2,952

radius in mm 168 171 165

run-up in sec 24

run-down in sec, braked 17

temperature in °C1) -8

lid with bio-containment4)

Cat. No. 5093

lid with bio-containment4)

Cat. No. 5093

12

ROTORS AND ACCESSORIES

illustrated with carriers 1742

) 90°

n = 4,000 min-1

max. RCF 2,808

Cat. No. (without carriers) 1726

Swing-out rotor, 6-place

1) Lowest attainable temperature in precooled refrigerated centrifuges at max. speed. Lower temperatures can be reached by reducing the speed. 2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers. The max. RCF for glass tubes annotated with footnote 2) is 4,000. 8) Please ask for our detailed cyto brochure.

capacity in ml 5 6 7 9 15 20 25 45 50 8.5 x 10 30

Ø x L in mm 12 x 75 12 x 82 12 x 100 14 x 100 17 x 100 21 x 100 24 x 100 31 x 100 34 x 100 16 x 100 26 x 95

Cat. No. 05532) 05012) 0578 2) 0500 2) 0518 2) - 0519 2) - 0521 2) blood coll.tube 0545

rotorCat. No. 1726

Cat. No. 1369-91 1372 1369-92 1370 1369 1346 1745 1345 1746 1369 1745

boring Ø x L in mm 12.5 x 64.4 13.5x 65 12,5 x 71,5 14.6 x 74 17.6 x 74 21.5 x 74 26 x 78 32 x 74 35 x 78 17.6 x 74 26 x78

tubes per rotor 24 102 24 30 24 12 6 24 12

max. RCF 2) 2,576 2,522 2,665 2,719 2,808 2,719 2,808 2,665 2,808

radius in mm 144 141 149 152 157 152 157 149 157

run-up in sec 19

run-down in sec, braked 18

temperature in °C1) -6

withdecanting aid

withdecanting aid

withdecanting aid

capacity in ml suspensions for cyto accessoriesØ x L in mm

Cat. No. cyto chambers 8)

rotorCat. No. 1726

Cat. No. 1660 1680

boring Ø x L in mm -

tubes per rotor 6

max. RCF 2) 2,003 1,825

radius in mm 112 102

run-up in sec 19

run-down in sec, braked 18

temperature in °C1) -6

13

capacity in ml 9 1.1–1.4 4.5–5 4.9 1.6–5 4–7

Ø x L in mm 14 x 100 8 x 66 11 x 92 13 x 90 13 x 75 13 x 100

Cat. No. 0500 2) blood collection tubes

carrierCat. No. 1741

10)

Cat. No. 0701 - - 6x0768 12) -

boring Ø x L in mm 14.6 x 78

tubes per rotor 60 36 60 60 60

max. RCF 2) 2,773 2,808 2,486 2,808

radius in mm 155 157 139 157

run-up in sec 19

run-down in sec, braked 18

temperature in °C1) -6

ROTORS AND ACCESSORIES

capacity in ml 1.5 2.0 1 3 4

Ø x L in mm 11 x 38 6 x 45 10 x 60 12 x 60

Cat. No. 2078 0536 Rhesus – –

carrierCat. No. 1366

Cat. No. 5277 1357 1327 1326

boring Ø x L in mm 11.5 x 38 6.5 x 23 10.5 x 23 12.5 x 44

tubes per rotor 54 180 72

max. RCF 2) 2,325 2,308 2,290

radius in mm 130 129 128

run-up in sec 19

run-down in sec, braked 18

temperature in °C1) -6

10) Carrier must be loaded as illustrated. 12) Packed in units of 10 pieces.

capacity in ml 15 2.6 – 3.4 4–5.5 7.5 – 8.5 9–10 10 1.6–5 4–7 8.5–10 15

Ø x L in mm 17 x 100 13 x 65 15 x 75 15 x 92 16 x 92 15 x 102 13 x 75 16 x 75 16 x 100 17 x 120

Cat. No. 0518 2) blood collection/urine tubes 0509

carrierCat. No. 1742

10) 10)

Cat. No. - 0716 - - 0716 -

boring Ø x L in mm 17.6 x 78

tubes per rotor 42 42 42 18 42 42 18

max. RCF 2) 2,808 2,683 2,808 2,683 2,808

radius in mm 157 150 157 150 157

run-up in sec 19

run-down in sec, braked 18

temperature in °C1) -6

rubber insert rubber insert

Cat. No. (without carriers) 1726

illustrated with carriers 1742

rubber insert

14

ROTORS AND ACCESSORIES

) 45°

n = 4,000 min-1

max. RCF 2,916

Cat. No. (with carriers) 1717

Swing-out rotor, 10-place

capacity in ml 15 50

Ø x L in mm 17 x 120 29 x 115

Cat. No. 0509 0513

rotorCat. No. 1717

Cat. No. 1462-A -

boring Ø x L in mm 17 x 84 38.4 x 89

tubes per rotor 10

max. RCF 2) 2,916

radius in mm 163

run-up in sec 19

run-down in sec, braked 14

temperature in °C1) - 9

D x W x H in mm 86 x 128 x 15/17.5 86 x 128 x 22 86 x 128 x 44.5 86 x 128 x 46 86 x 128 x 83 59 x 84 x 11 82 x 124 x 20 -

Cat. No. MTP CP DWP MS QPMicrotest Plate

(Terasaki)PCR Plate,

96 wellsPCR

strips

rotorCat. No. 1760

Cat. No. 1753-A 1753-A + 1485

boring Ø x L in mm -

plates/strips per rotor 10 8 6 2 2 2 4 2 24 x 8

max. RCF 2) 2,397

radius in mm 134

run-up in sec 30

run-down in sec, braked 23

temperature in °C1) - 8

Swing-out rotor, 2-place

) 90°

n = 4,000 min-1

max. RCF 2,397

Cat. No. (without carriers) 1760

1) Lowest attainable temperature in precooled refrigerated centrifuges at max. speed. Lower temperatures can be reached by reducing the speed. 2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers. The max. RCF for glass tubes annotated with footnote 2) is 4,000. 5) The screw cap for tube No. 0538 is available with Cat. No. 0539. Dimensions with cap 38 x 106 mm.

15

ROTORS AND ACCESSORIES

) 45°

ROTINA 380 R n = 11,000 min-1, max. RCF 16,369

ROTINA 380 n = 10,000 min-1, max. RCF 13,528

Cat. No. 1720

Angle rotor, 6-place

capacity in ml 1.5 2.0 15 25 50 75 94 7.5–8.5 9–10

Ø x L in mm 11 x 38 17 x 100 24 x 100 34 x 100 35 x 105 38 x 102 15 x 92 16 x 92

Cat. No. 2078 0536 05182) 05192) 05212) 0548 0549 blood/urine tubes

rotorCat. No. 1720

Cat. No. 1449 1451 1447 1463 - 1451

boring Ø x L in mm 11.4 x 39 17.5 x 92 26 x 85 35 x 89 38.4 x 89 17.5 x 92

tubes per rotor 24 6 6 6 6 6

max. RCF 2) classic/cooled 12,969/15,692 12,745/15,422 12,410/15,016 13,304/16,098 13,528/16,369 12,745/15,422

radius in mm 116 114 111 119 121 114

run-up in sec classic/cooled 39/45

run-down in sec classic/cooled, braked 36/44

temperature in °C1) +1

capacity in ml 8.5–10 15 50 10 30 50 85 94

Ø x L in mm 16 x 100 17 x 120 29 x 115 16 x 80 26 x 95 29 x 107 38 x 106 38 x 102

Cat. No. blood/urine tube 0509 0513 - 0545 0546 0547 0538 5)

rotorCat. No. 1720

Cat. No. 1451 1466 1454 1448 1447 1446 -

boring Ø x L in mm 17.5 x 92 17 x 106 29.8 x 97 16.5 x 74 26 x 85 29 x 92 38.4 x 89

tubes per rotor 6 6 12 6 6

max. RCF 2) classic/cooled 12,745/15,422 13,081/15,828 12,745/15,422 12,410/15,016 12,410/15,016 12,969/15,692 13,528/16,369

radius in mm 114 117 114 111 111 116 121

run-up in sec classic/cooled 39/45

run-down in sec classic/cooled, braked 36/44

temperature in °C1) +1

16

ROTORS AND ACCESSORIES

) 45°

ROTINA 380 R n = 11,000 min-1, max. RCF 16,504

ROTINA 380 n = 10,000 min-1, max. RCF 13,640

Cat. No. 1792

Angle rotor, 6-place

with bio-containment4)

capacity in ml 1.5 2.0 15 25 50 75 94 7.5–8.5 9 –10

Ø x L in mm 11 x 38 17 x 100 24 x 100 34 x100 35 x105 38 x 102 15 x 92 16 x 92

Cat. No. 2078 0536 0518 2) 0519 2) 05212) 0548 0549 blood/urine tubes

rotorCat. No. 1792

Cat. No. 1449 1451 1447 1463 - 1451

boring Ø x L in mm 11.4 x 39 17.5 x 92 26 x 85 35 x 89 38.2 x 89.6 17.5 x 92

tubes per rotor 24 6

max. RCF 2) classic/cooled 13,081/15,828 12,857/15,557 12,522/15,151 13,640/16,504 13,640/16,504 12,857/15,557

radius in mm 117 115 112 122 122 115

run-up in sec classic/cooled 40/48

run-down in sec classic/cooled, braked 37/44

temperature in °C1) +4

lid with bio-containment4) incl.

capacity in ml 10 8.5–10 15 50 10 30 50 85 94

Ø x L in mm 15 x 102 16 x 100 17x 120 29 x115 16 x 80 26 x 95 29 x 107 38 x 106 38 x 102

Cat. No. blood/urine tubes 0509 0513 - 0545 0546 0547 05385)

rotorCat. No. 1792

Cat. No. 1451 1466 1454 1448 1447 1446 -

boring Ø x L in mm 17.5 x 92 17 x 106 29.8 x 97 16.5 x 74 26 x 85 29 x 92 38.2 x 89.6

tubes per rotor 6 12 6

max. RCF 2) classic/cooled 12,857/15,557 13,081/15,828 13,304/16,098 12,857/15,557 12,522/15,151 13,081/15,828 13,640/16,504

radius in mm 115 117 119 115 112 117 122

run-up in sec classic/cooled 40/48

run-down in sec classic/cooled, braked 37/44

temperature in °C1) +4

lid with bio-containment4) incl.

1) Lowest attainable temperature in precooled refrigerated centrifuges at max. speed. Lower temperatures can be reached by reducing the speed. 2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers. The max. RCF for glass tubes annotated with footnote 2) is 4,000. 4) Tested by the TÜV in conformity with DIN EN 61010, section 2-020.

17

ROTORS AND ACCESSORIES

Angle rotor, 30-place

) 45°

n = 15,000 min-1

max. RCF 24,400

Cat. No. 1789-A

with bio-containment4)

capacity in ml 0.2 0.4 0.5 0.8 1.5 2.0 0.5

Ø x L in mm 6 x 18 6 x 45 8 x 30 8 x 45 11 x 38 10.7 x 36

Cat. No. - 2078 0536 Pediatric

rotorCat. No. 1789-A

Cat. No. 2024 2023 203111) - 078813)

boring Ø x L in mm 6 x 40 8 x 40 10.2 x 19 11.2 x 40.9

tubes per rotor 30 15

max. RCF2) 24,400 23,394

radius in mm 97 93

run-up in sec 24

run-down in sec, braked 24

temperature in °C1) +4

lid with bio-containment4)

incl.

5) The screw cap for tube No. 0538 is available with Cat. No. 0539. Dimensions with cap 38 x 106 mm. 11) For centrifugation at high speeds, we recommend to use form-fitting, phenol-resistant adapters 2031. 13) Packed in units of 15 pieces.

capacity in ml 0.2 0.4 0.5 0.8 1.5 2.0

Ø x L in mm 6 x 18 6 x 45 8 x 30 8 x 45 11 x 38

Cat. No. - 2078 0536

rotorCat. No. 1711

Cat. No. 1378 1379 1377

boring Ø x L in mm 6 x 40 8.4 x 43 10.8 x 37

tubes per rotor 192 126 60

max. RCF2) 18,866

radius in mm 75

run-up in sec 25

run-down in sec, braked 23

temperature in °C1) +2

lid incl.

Drum rotor, 6-place

illustrated withadapters 1377

n = 15,000 min-1

max. RCF 18,866

Cat. No. (without adapters) 1711

18

ROTORS AND ACCESSORIES

1) Lowest attainable temperature in precooled refrigerated centrifuges at max. speed. Lower temperatures can be reached by reducing the speed. 2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers. The max. RCF for glass tubes annotated with footnote 2) is 4,000.

Angle rotor, 8-place

) 45°

n = 4,500 min-1

max. RCF 3,305

Cat. No. (without adapters) 1721

Cyto rotor, 8-place

Detailed information on our comprehensive range of cyto accessories is provided in a separate brochure. We will be pleased to send one to you on request.

n = 4,000 min-1

max. RCF 2,415

Cat. No. (without suspensions) 1748

capacity in ml 5 15 1.1–1.4 2.6–3.4 2.7–3 9–10 1.6–5 4– 7 8.5– 10 12 15 50

Ø x L in mm 12 x 75 17x100 8 x 66 13 x 65 11 x 66 16 x 92 13 x 75 13x100 16x100 17x102 17x120 29 x 115

Cat. No. 05532) 05182) blood collection/urine tube 0509 0513

rotorCat. No. 1721

+ 1054-A + 0716 + 1054-A + 0716 + 1054-A + 0716 + 0716 + E 2109 + E 2110-A

Cat. No. 1467 1467 1467 1467 1468

boring Ø x L in mm 17.4 x 91 17.4 x 91 17.4 x 91 30.2 x 92

tubes per rotor 32 32 32 8

max. RCF2) 2,762 3,215 2,762 3,215 2,762 3,305 3,215 3,283 3,147

radius in mm 122 142 122 142 122 146 142 145 139

run-up in sec 17

run-down in sec, braked 14

temperature in °C1) - 11

capacity in ml 12 50 50

Ø x L in mm 17x100 29 x 115 29 x107

Cat. No. - - 0546

rotorCat. No. 1721

+ 0716

Cat. No. 1467 1468

boring Ø x L in mm 17.4 x 91 30.2 x 92

tubes per rotor 32 8

max. RCF2) 3,215 3,147

radius in mm 142 139

run-up in sec 17

run-down in sec, braked 14

temperature in °C1) - 11

19

770

550

550

550

770550

260 260

ROLLING CABINETS

Rolling cabinets for Hettich centrifuges save space on the laboratory bench while ensuring enhanced flexibility.

All rolling cabinets are of sturdy design and feature castors and two locks. Any vibrations of the centrifuge are safely compensated for.

Rolling cabinets with Cat. No. 4612-A and 4613-K are suited for the models:● ROTOFIX 32 A● UNIVERSAL 320 / 320 R● ROTINA 380 / 380 R● ROTINA 420● ROTANTA 460● ROTOFIX 46 / 46 H

Rolling cabinets with Cat. No. 4614-K and 4615-A are suited for the models:● ROTINA 420 R● ROTANTA 460 R

High and wide,with two drawers.Depth 650 mm

Cat. No. 4615-A

High and narrow,with two drawers.Depth 650 mm

Cat. No. 4613-K

Low and wide,with one drawer.Depth 650 mm

Cat. No. 4614-K

Low and narrow,with one drawer.Depth 650 mm

Cat. No. 4612-A

P17

01G

B.0

214

© b

y H

ettic

h Tu

ttlin

gen

· P

rinte

d in

Ger

man

y ·

Des

ign,

for

m a

nd c

olou

r m

odifi

catio

ns r

eser

ved

.

*) Other voltages on request.

TECHNOLOGY ROTINA 380 ROTINA 380 R

Benchtop centrifuge, without rotor classic cooled

Power supply*) 200 – 240 V 1 p 100 – 127 V 1 p 200 – 240 V 1 p 110 – 127 V 1 p

Frequency 50 – 60 Hz 50 – 60 Hz 60 Hz

Consumption 650 VA 700 VA 1,300 VA 1,400 VA

Emission, Immunity EN / IEC 61326-1,class B

FCC class BEN / IEC 61326-1,

class BFCC class B

Max. capacity 4 x 290 ml

Max. RPM (speed) 15,000 min-1

Max. RCF 24,400

Running time 1 sec – 99 h : 59 min : 59 sec, continuous run, short cycle mode (impulse key)

Dimensions (H x W x D) 418 x 457 x 600 mm 418 x 457 x 750 mm

Weight approx. 51 kg approx. 58.5 kg approx. 81 kg approx. 88.5 kg

Refrigeration

Temperature control, infinitely variable - from -20 to + 40 °C

Cat. No. 1701 1701-01 1706 1706-01

Hettich centrifuges comply with all relevant EU standards in effect and conform to the Europeanlevel of quality and safety for medical devices. Evidence is provided by national and internationaltest marks such as IEC 61010 or the CE conformity. The ISO 9001, ISO 13485 and ISO 14001 certificates accredited to the company bear witness to the extreme care and responsibility Hettich puts into the manufacturing of centrifuges and their accessories.

Andreas Hettich GmbH & Co. KGFöhrenstr. 12D-78532 TuttlingenGermany

[email protected]@hettichlab.com

Phone +49 (0)7461 / 705 -0 Fax +49 (0)7461 / 705 -1122

National Sales: -12 00International Sales: -12 01National Service: -12 02International Service: -12 03

We are an Authorised Economic Operator, which means you can expect expeditious customs clearance.

ROTINA 380/380 R