F:\AESBusinessSystems\AES Technical\Piece part instructions\CF25 Furnacne assembly.doc
Room Fan Blower Assembly Complete #CF25
For 6500 & 7500 furnance
• CF31 Blower Housing w/ mounting feet • CF32 Blower Capacitor • CF33 Blower motor
Wire connections:
• Red wire for low output (not used) • Yellow wire high output • Black common
• Remove all parts from boxes. • Mount the mounting bracket to the blower motor see instruction. Make sure that all 3 legs of bracket are
equal and the there is amount 2 holes shown.
• Add a male connector to the black and
yellow lead from the blower motor. Connect the capacitor to the blow leads in position shown.
CF32 Blower capacitor
CF31 blower housing w/ hardware
2 holes shown
F:\AESBusinessSystems\AES Technical\Piece part instructions\CF25 Furnacne assembly.doc
• Using a tie wrap neatly wrap the red lead and the
capacitor leads together. Fasten the capacitor to the blower housing using tie wrap.
• Mount the blower assembly to the blower housing using the #14 bolts supplied. The housing must be straight or motor with be off set.
• Ground the green lead to housing. • Evenly space the fan housing inside the blower housing. • Tighten the set screw making sure it is on the flat side of the blower motor shaft. • Box if necessary.
#14 screw (3x)