1
CASEMENT AIR CONDITIONER USER’S MANUAL
MODEL: SIN-TC1
2
FOREWORD
Casement air-conditioners are pieces of high value. In order to ensure your lawful rights
and interests, please have the professional technicians to do the installation for you.
This instruction manual is the universal-purpose version for the units that you purchase
might be slightly different from the ones described in the manual, but it does not affect
your proper operations and usage.
Please read carefully the sections corresponding to the specific model you choose, and
keep the manual properly so as to facilitate your reference at later time.
Attention:
(1) The appliance is not intended for using by young children or infirm persons without
supervision.
(2) Young children should be supervised to ensure that they do not play with the
appliance.
(3) The plug shall be accessible after install the appliance.
(4) The appliance shall be installed in accordance with national wiring regulation.
(5) The appliance can’t be installed in laundry.
(6) If the supply cord is damaged, it must be replaced by the manufacturer or its service
agent or a similarly qualified person in order to avoid a hazard.
3
CASEMENTAIR-CONDITIONER
This casement air-conditioner is a small size appliance, which can adjust the
temperature and humidity in a room. Its flexibility characteristics make it easily used on
different occasions in different rooms. It also has multiple functions, including cooling,
dehumidifying and fanning ventilation. This unit was designed especially to be used in a
family house, office, etc. It has a compact design compared to others with the same
cooling capacity. Power consumption is low and the noise especially low.
Features of heating operation: the machine heating operation, the principle is that the
air is heating by the heating pump before sent out. The function is not affected by
ambient temperature.
Features of cooling operation: Other air conditioning patterns are recommended when
the indoor temperature is either below 170C(630F) or above 350C(950F).
ATTENTION
Before you use your casement air-conditioner, please read this instruction manual
carefully so that you get the best from the unit.
This instruction manual is used for guidance and does not form part of a contract.
We reserve the right to make technical changes without prior notice.
1
PRECAUTION ON INSTALLATIONS
220-240VAC?
Please install the unit 75-150cm
above the ground.
The intake and discharge vents unit
should not be obstructed.
The unit be plugged into its own
individual outlet that has a voltage
rating suitable for normal operation
(220V-240V)
The unit should not be directly
exposed to sunlight or rain.
The fixing between the mounting kit and
window should be secured. The six
screws shown below must be well fixed.
2
PARTS IDENTIFICATION
OPERATION
3
INSTRUCTION
AIR CONDITIONER CONTROLS
1、POWERPress this button for three seconds ,the unit will be turned on,and press this button
for three seconds again ,the unit will be turned off.
When the unit running, press this button, you can choose one of the operation modes: AUTO,
COOL, DEHUMIDIFYING and FAN.
2、Temperature set controlUse for adjusting the temperature.
4
The default display on control panel is setting temperature.
When “+” or “-“key is pressed, the set temperature is displayed and may be adjusted.
OPERATION AND INDICTION SECTIONS OF REMOTE CONTROLLER
1. POWER2. MODE3. TIMER4. SPEED5. TEMP+6. TEMP-7. SLEEP
On/Off switchMODE selectorHourly programmingFan speed selectorTemperature selector upTemperature selector downNight operation selector
5
USE OF CONTROL PANELPOWER SOURCE
The AC socket must be firm and reliable.Don’t connect the casement air-conditioner to a multiply socket outlet which is also being used for other electrical
appliances.Inset the AC power plug securely into the AC socket using the unit, when it beeps after two seconds, press ”ON/OFF”
button, the unit begins to run.AUTO OPERATION1. Repeatedly press”MODE” button to choose the AUTO mode, The AUTO mode LED light and corresponding
operation mode light will light up.2. The product will deliver cooled air when room temperature is above 260C.3. The product will operate in DRYMODE when room temperature is above 230C to 260C.4. The product will simply circulate room temperature air when room temperature is 230C or below5. Press “SPEED” button to choose a proper fan speed, high, middle, low speed.
COOLING OPERATION1. Repeatedly press”MODE” button to choose the cooling mode, The COOL mode LED light will light up.2. Repeatedly press”TEMP+” or “TEMP-“button to set a proper room TEMP. at 160C-310C.3. Press “SPEED” button to choose a proper fan speed, high, middle, low speed.NOTE:In order to improve the cooling efficiency, be careful that:a) If your room is directly exposed to the sun, draw the curtains please.b) Do no place near other heat source.DEHUMIDIFYING OPERATION1. Keep the windows and the doors closed to aid in effectively dehumidifying the room.2. Repeatedly press the “MODE” button to choose the dehumidifying mode, The DEHUM mode LED light will light up.,
the fan speed cannot be adjusted.FAN OPERATION
1. Repeatedly press the “MODE” button, select the heat mode. The FAN mode LED light will light up..2. Press “SPEED” button to choose the fan speed: high-middle-low.
TIME SET FUNCTIONTo set time to start the machine with the unit off (but power supplied), press “TIMER” button, the LCD window will show“ OFF”, press the “TIME “ button, set the time to start as you like. The setting range is 1-12 hours.If have set switch on/off after 12 hours, press this key again there could cancel the timing.
6
OPERATION PROCEDURES
■ ELECTRICAL CIRCUIT OPERATION FO DEHUMIDIFICATION
1.Press the “ON/OFF” button.
2.Press the “Function” button to select the “DRY” for dehumidification function
3.Press the “ON/OFF” key again if you wish to stop.
25
20
15
10
5
20 24 27 30 (DB )℃
RH 90%RH 80%RH 70%RH 60%
L/ d ay (RH) %
85
65
45
40
5
1 hr 2 hr 3 hr 4 hr
DBT lineDBT lin e
RH li ne
RH lineDBT )℃(
24
16
1℃
* qua ntity o f dehumidi f ication for un it operating * at 24 -85% for room area of 16.2m 2℃
INSTALLTION INSTRUCTIONS
Casement air-conditioners are pieces of high value. In order to ensure your lawful rights and
interests, please have the professional technicians to do the installation for you.
Width:390mm
Indoors
Outdoors
Height:840~1370mm
◆ MAIN STEPS OF INSTALLATION
● Unit can be installed on the left or right side of a sliding window.
7
1. Fix the mounting Kit securely 2.Insert the unit on the bottom of kit.
in the window. the mounting
8
3. Push the unit forward and screw the Body-Angle (upper) with the mounting Kit.
9
5 6 78
4321
No.12345678
Piece14422116
102
Name of componentsMounting kitInsulating material (hard)Insulating material (soft)PadSub fixture stopperSealScrew E4 20 E4 10 E4 12
×
×
×
LIST OF THE INSTALLING COMPONENTS
10
Attaching the Window Panel Material:
Fill the gaps between the installing frame and the window post to prevent water leaking
indoors
● Fixing the Mounting Kit:
A. To be fixed on the Aluminum Door & Window.
1. Place the mounting kit(lower) on the flange of thealuminum door & window.Push upward and rightwardto get close to the windowpost.
2. Fix the mounting kit(upper & lower) tightlywith screws.
3.fix the mounting kitsecurely with thealuminum door &window.
11
B. Fixing on the wooden window.
3. Tighten the screws at both sides after
mounting.
1. Put the sub fixtures on the wooden
window frame (up and down), and fix
them tightly with screws. The up and
down fixtures should be at the same
vertical position.
2. Place the mounting kit on the sub
fixtures.
4. Fix the mounting kit and fixtures tightly
with screws.
12
SPECIAL ATTENTION
DO NOT OPERATE IN THE FOLLOWING STATES
Room temperature is below21℃.
Outside temperature is up to 43℃.(The protective device will stop the air conditioner.)
Wait 3 minutes for restarting the air conditioner.
MAINTENANCE
Before cleaning the air-conditioner, always turn off and disconnect the power supply.1. Air filter cleaning
Must turn “OFF” the air conditioner
first before unplugging.
Must insert the plug properly into
the wall outlet.
13
2.
3. Cabinet & Front Panel Cleaning
● Wipe the cabinet and front
panel regularly.
● Do not use spraying type insecticide
directly on the unit.
●Do not use volatile substances
such as gasoline, toluene or
diluents to clean the cabinet and
front panel.
●Do not wash the unit directly with
running water.
*Remove the filter by pulling it out as
shown below.
*Wash the filter once every 1-2weeks to
maximize the performance of the air
conditioner and to keep the air flowing
freely.
*Use water (under 40℃) or soft cleaning
agents to soft the filter (Let it dry first
before putting it back.)
*Do not use volatile substances such as
gasoline, toluene or diluents to clean the
filter.
14
BEFORE CALLING FOR SERVICE
1. Air conditioner does not start
2.Air conditioner does not cool as it should.
Whether the power supply
plug is loosened or
disconnected?
Is the fuse blown or circuit
breaker tripped?
Is the power source
correct?
15
3. The following conditions are not normal for the product:
● When the surrounding humidity is at 80% or above, condensation may occur after prolonged
operation. In addition, some dripping may occur.
● Slight of fluid flowing is normal, it is due to coolant flowing in the system.
IMPORTANT WARNINGS
●if the supply cord is damaged, it must be replaced by the manufacturer, its service agent
or similarly qualified persons in order to avoid a hazard.
● Repair or replace immediately all electric cords that have become frayed or otherwise damaged.
● The unit shall be installed in accordance with the national wiring regulations.
● In high humidity (over 80%) conditions, the unit may experience some splashing of water
droplets at the condenser side.
● The maximum and minimum operating temperature of the hot and cold sides.
Indoor: Dry bulb : 21℃ to 32℃
Wet bulb : 16℃ to 23℃
Outdoor: Dry bulb: 24℃ to 43℃
Wet bulb: 21℃ to 26℃
Remark:
In the interest of product improvement,the specifications may be change without prior notice.