LG RoomAir ConditionerSERVICE MANUAL
LG
CAUTION
website http://www.lgservice.com
• BEFORE SERVICING THE UNIT, READ THE SAFETY PRECAUTIONS IN THIS MANUAL.
• ONLY FOR AUTHORIZED SERVICE PERSONNEL.
MODEL: L5004R
2 Room Air Conditioner
Air Conditioner Service Manual
TABLE OF CONTENTSSafety Precautions..........................................................................................................................................3Dimensions .....................................................................................................................................................7
Outside Dimensions ...................................................................................................................................7Product Specifications ..................................................................................................................................8Installation .......................................................................................................................................................9
Select the Best Location ............................................................................................................................9How to Install ..............................................................................................................................................9Installation Kits Contents .........................................................................................................................10How to Secure the Drain Pipe....................................................................................................................11
Operation ......................................................................................................................................................12Feature ....................................................................................................................................................12About the Controls of the Air Conditioner ................................................................................................13
Disassembly ..................................................................................................................................................14Mechanical Parts......................................................................................................................................14Air Handling Parts ....................................................................................................................................15Electrical Parts .........................................................................................................................................16Refrigerating Cycle...................................................................................................................................17
Schematic Diagram .......................................................................................................................................20Circuit Diagram.........................................................................................................................................20Electronic Control Device .........................................................................................................................21Components Location(For Main P.W.B ASM)...........................................................................................22
Troubleshooting Guide .................................................................................................................................23Piping System ........................................................................................................................................23Troubleshooting Guide .............................................................................................................................24
Exploded View ..............................................................................................................................................32Replacement Parts List ................................................................................................................................33
Service Manual 3
Safety Precautions
Safety PrecautionsTo prevent injury to the user or other people and property damage, the following instructions mustbe followed.� Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is
classified by the following indications.
� Meanings of symbols used in this manual are as shown below.
Service Manual 3
Safety Precautions
Safety PrecautionsTo prevent injury to the user or other people and property damage, the following instructions mustbe followed.� Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is
classified by the following indications.
� Meanings of symbols used in this manual are as shown below.
Service Manual 3
Safety Precautions
Safety PrecautionsTo prevent injury to the user or other people and property damage, the following instructions mustbe followed.� Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is
classified by the following indications.
� Meanings of symbols used in this manual are as shown below.
Service Manual 3
Safety Precautions
Safety PrecautionsTo prevent injury to the user or other people and property damage, the following instructions mustbe followed.� Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is
classified by the following indications.
� Meanings of symbols used in this manual are as shown below.
WARNING This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to property only.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to property only.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to property only.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to property only.
WARNING� InstallationAlways install the expansion panel(s).
• Improper assembly or installation may cause incorrectoperation, including injury, fire, and electric shock haz-ards.
Do not place the power cord near a heater.• It may cause fire and electric shock.
Be sure not to do.
Be sure to follow the instruction.
� InstallationAlways install the expansion panel(s).
• Improper assembly or installation may cause incorrectoperation, including injury, fire, and electric shock haz-ards.
Do not place the power cord near a heater.• It may cause fire and electric shock.
Be sure not to do.
Be sure to follow the instruction.
� InstallationAlways install the expansion panel(s).
• Improper assembly or installation may cause incorrectoperation, including injury, fire, and electric shock haz-ards.
Do not place the power cord near a heater.• It may cause fire and electric shock.
Be sure not to do.
Be sure to follow the instruction.
� InstallationAlways install the expansion panel(s).
• Improper assembly or installation may cause incorrectoperation, including injury, fire, and electric shock haz-ards.
Do not place the power cord near a heater.• It may cause fire and electric shock.
Be sure not to do.
Be sure to follow the instruction.
Do not use the power cord near flammable gasor combustibles such as gasoline, benzene,thinner, etc.
• It may cause explosion or fire.
Do not disassemble or modify products.
• It may cause electric shock and failure.
GasolinGasolinGasolinGasolinGasolinGasolinGasolinGasolin
CAUTION
4 Room Air Conditioner
Safety Precautions
Plug in the power plug prop-erly.
• Otherwise, it will cause electricshock or fire.
Do not operate or stop theunit by inserting or pullingout the power plug.
• It will cause electric shock or fire.
Do not damage or use anunspecified power cord.
• It will cause electric shock or fire.
4 Room Air Conditioner
Safety Precautions
Plug in the power plug prop-erly.
• Otherwise, it will cause electricshock or fire.
Do not operate or stop theunit by inserting or pullingout the power plug.
• It will cause electric shock or fire.
Do not damage or use anunspecified power cord.
• It will cause electric shock or fire.
4 Room Air Conditioner
Safety Precautions
Plug in the power plug prop-erly.
• Otherwise, it will cause electricshock or fire.
Do not operate or stop theunit by inserting or pullingout the power plug.
• It will cause electric shock or fire.
Do not damage or use anunspecified power cord.
• It will cause electric shock or fire.
4 Room Air Conditioner
Safety Precautions
Plug in the power plug prop-erly.
• Otherwise, it will cause electricshock or fire.
Do not operate or stop theunit by inserting or pullingout the power plug.
• It will cause electric shock or fire.
Do not damage or use anunspecified power cord.
• It will cause electric shock or fire.
Do not modify power cordlength.
• It will cause electric shock or fire
Use the air conditioner on asingle outlet circuit.(See page7.) Do not share the outletwith other appliances.
Always plug into a groundedoutlet.
• No grounding may cause electric
Unplug the unit if strangesounds, odors, or smokecome from it.
• Otherwise it will cause fire andelectric shock accident.
Do not use the socket if it isloose or damaged.
• It may cause fire and electric
Do not operate with wethands or in damp environ-ment.
• It ma cause electric shock.
� Operation� Operation� Operation� Operation
ON
• It will cause electric shock or fire.shock.
shock.
Service Manual 5Service Manual 5Service Manual 5Service Manual 5
Close all doors, windows and other outsideopenings to the room.
• The air conditioner must be operated in a enclosedarea to be most effective.
Ventilate before operating air conditionerwhen gas goes out.
• It may cause explosion, fire, and burn.
����
Do not clean the air conditioner with water.If water enters the product, turn off the powerswitch of the main body of appliance. Contactservice center after taking the power plug utfrom the socket.
• Water may enter the unit and degrage the insulation. It may cause an electric shock.
CAUTIONInstallation
• There is risk of fire or electric shock.
Never touch the metal partsof the unit when removingthe filter.
• They are sharp and may causeinjury.
Do not block the inlet or out-let.
• It may cause failure of appliance orperformance deteriorate.
Ensure that the outer case isnot damaged by age or wear.
• If the outer case is damaged, itmust be repaired or replacedimmediately. Leaving it damagedcould result in the air conditionerfalling out of the window, creatinga safety hazard.
• Since the fan rotates at high speedduring operation, it may causeinjury.
• This could injury the pet or plant. • It is an air conditioner, not a preci-sion refrigeration system.
6 Room Air Conditioner6 Room Air Conditioner6 Room Air Conditioner6 Room Air Conditioner
Unplug the air conditionerbefore cleaning it.
Do not put a pet or nouseplant where it will be exposedto direct air flow
Do not use this appliance forspecial purposes such aspets, foods, precisionmachinery, or objucts of art.
Be cautious not to touch thesharp edges when installing
• It may cause injury.
Hold the plug by the headwhen taking it out.
• It may cause electric shock anddamage.
Unplug the air conditioner ifit will not be used for a longperiod.
• It will waste power consumption invain and it may cause accident.
Sharp edges
Always insert the filtersecurely. Clean it every twoweeks.
• Operation without filters will causefailure.
Use a soft cloth to clean. Donot use wax, thinner, or astrong detergent.
• The appearance of the air condi-tioner may deteriorate, changecolor, or develop surface flaws.
Do not drink water drainedfrom air conditioner. Do notdirect airflow at room occu-pants only.
• It is not sanitary and could causeillness or personal injury hazard.
Wax ThinnerWax Thinner
� Operation� Operation
Service Manual 7
Dimensions
Dimensions
H
DW
W mm(inch) 439(17 5/16")
H mm(inch) 283(11 1/8")
D mm(inch) 326(12 13/16")
Model
DimensionAll Model
Outside Dimensions
This symbol alerts you to the risk of electric shock.
This symbol alerts you to hazards that could cause harm to theair conditioner.
This symbol indicates special notes.NOTICE
Symbols Used in this Manual
8 Room Air Conditioner
Product Specifications
Product Specifications
SPECIFICATIONS ARE SUBJECT TO MINOR CHANGE WITHOUT NOTICE FOR FURTHERIMPROVEMENT.
8 Room Air Conditioner
Product Specifications
Product Specifications
SPECIFICATIONS ARE SUBJECT TO MINOR CHANGE WITHOUT NOTICE FOR FURTHERIMPROVEMENT.
8 Room Air Conditioner
Product Specifications
Product Specifications
SPECIFICATIONS ARE SUBJECT TO MINOR CHANGE WITHOUT NOTICE FOR FURTHERIMPROVEMENT.
8 Room Air Conditioner
Product Specifications
Product Specifications
SPECIFICATIONS ARE SUBJECT TO MINOR CHANGE WITHOUT NOTICE FOR FURTHERIMPROVEMENT.
NOTICE
COOLING CAPACITY (BTU/h) 5,050
POWER SUPPLY (Phase, V, Hz) 1ø, 115V, 60HZ
INPUT (W) 520
OPERATING CURRENT (AMP.) 4.8
REFRIGERANT CONTROL CAPILLARY TUBE
REFRIGERANT CHARGE (R-22) 205g(7.2 Oz)
INSIDE FAN TURBO
OUTSIDE FAN ROPELLER FAN WITH SLINGER RING
AIR DISCHARGE 2-WAY (RIGHT AND LEFT)
CHASSIS TOP-DOWN
PROTECTOR
TEMPERATURE CONTROL THERMISTOR
• OVERLOAD PROTECTOR FOR COMPRESSOR• INTERNAL PROTECTOR FOR FAN MOTOR
GL5004MODELS
ITEMS
COOLING CAPACITY (BTU/h) 5,050
POWER SUPPLY (Phase, V, Hz) 1ø, 115V, 60HZ
INPUT (W) 520
OPERATING CURRENT (AMP.) 4.8
REFRIGERANT CONTROL CAPILLARY TUBE
REFRIGERANT CHARGE (R-22) 205g(7.2 Oz)
INSIDE FAN TURBO
OUTSIDE FAN ROPELLER FAN WITH SLINGER RING
AIR DISCHARGE 2-WAY (RIGHT AND LEFT)
CHASSIS TOP-DOWN
PROTECTOR
TEMPERATURE CONTROL THERMISTOR
• OVERLOAD PROTECTOR FOR COMPRESSOR• INTERNAL PROTECTOR FOR FAN MOTOR
MODELS
ITEMS
COOLING CAPACITY (BTU/h) 5,050
POWER SUPPLY (Phase, V, Hz) 1ø, 115V, 60HZ
INPUT (W) 520
OPERATING CURRENT (AMP.) 4.8
REFRIGERANT CONTROL CAPILLARY TUBE
REFRIGERANT CHARGE (R-22) 205g(7.2 Oz)
INSIDE FAN TURBO
OUTSIDE FAN ROPELLER FAN WITH SLINGER RING
AIR DISCHARGE 2-WAY (RIGHT AND LEFT)
CHASSIS TOP-DOWN
PROTECTOR
TEMPERATURE CONTROL THERMISTOR
• OVERLOAD PROTECTOR FOR COMPRESSOR• INTERNAL PROTECTOR FOR FAN MOTOR
MODELS
ITEMS
COOLING CAPACITY (BTU/h) 5,050
POWER SUPPLY (Phase, V, Hz) 1ø, 115V, 60HZ
INPUT (W) 520
OPERATING CURRENT (AMP.) 4.8
REFRIGERANT CONTROL CAPILLARY TUBE
REFRIGERANT CHARGE (R-22) 205g(7.2 Oz)
INSIDE FAN TURBO
OUTSIDE FAN ROPELLER FAN WITH SLINGER RING
AIR DISCHARGE 2-WAY (RIGHT AND LEFT)
CHASSIS TOP-DOWN
PROTECTOR
TEMPERATURE CONTROL THERMISTOR
• OVERLOAD PROTECTOR FOR COMPRESSOR• INTERNAL PROTECTOR FOR FAN MOTOR
MODELS
ITEMS
Service Manual 9
Window Requirements
All supporting parts should be secured to firmwood, masonry, or metal.
1. This unit is designed for installation in standard doublehung windows with actual opening widths of 21" to 35".The upper and lower sash must open sufficiently to allowa clear vertical opening of 12" from the bottom of thesash to the window stool.
2. If storm window presents interference, fasten a 2" widewood strip to the inner window sill across the full width ofthe sill. The wood strip should be thick enough to raisethe height of the window sill so that the unit can beinstalled without interference by the storm window frame.See Figure. 3. Top of wood strip should be approximately3/4" higher than the storm window frame (STORM WIN-DOW FRAME) or wood strip (OUTDOORS) to help con-densation to drain properly to the outside.
3. Install a second wood strip (approximately 6" long by11/2" wide and same thickness as first strip) in the centerof the outer sill flush against the back off the inner sill.This will raise the L bracket as shown Figure. 3.
4. If the distance between STORM WINDOW FRAME andWOOD STRIP MOUNTED ON TOP OF INNER SILL ismore than 1", two of wood strip are not necessary.
NOTICE
Installation
Installation
Select the Best Location
How to Install
This air conditioner is designed with a button-down chassis so it can be easily installed in a window.
1. To prevent vibration and noise, make sure the unit isinstalled securely and firmly.
2. Install the unit where the sun does not shine directly onthe unit.
3. The outside of the cabinet must extend outward for atleast 10" and there should be no obstacles, such as afence or wall, within 20" from the back of the cabinetbecause it will prevent heat radiation of the condenser.Restriction of outside air will greatly reduce the coolingefficiency of the air conditioner.
CAUTION: All side louvers of the cabinetmust remain exposed on the outdside ofthe structure.
4. Install the unit slanted slightly so the back is slightlylower than the front (about 1/4"). This will force con-densed water to the outside.
5. Install the unit with the bottom about 30"~60" above thefloor level.
ABOUT / "
Over 20"
HEATRADIATION
FENCEAWNING
OUTSIDE INSIDE
COOLED AIR
30"-6
0" 12
OUTDOORSINDOORS
INNER SILL
OUTERSILL
INNERSILL
WOOD STRIP MOUNTEDON TOP OF INNER SILL
WOOD STRIPFOR L BRACKET
3/4"CLEARANCE
1" MAX.
STORMWINDOWFRAME
OUTDOORSINDOORS
OUTERSILL
Figure 1
Figure 2
Figure 3
10 Room Air Conditioner
Installation
Installation Kits Contents(some Models)
Before Installation (Some Models IncludingInstallation Kit)1. Insert the guide panels into the guides of the air conditioner.
Fasten the curtains to the unit with screws (TYPE A), as shownFigure. 4.
2. Cut the adhesive-backed seal strip (TYPE E) to the windowwidth.Remove the backing from the seal strip and attach the seal stripto the underside of the bottom window. (Figure. 5)
Start Installation (Some Models IncludingInstallation Kit)1. Locating Unit in Window
Open the window and mark center line with pencil on the centerof the inner sill, as shown in Figure. 6.
2. Attach L Bracketa. Install the L brackets behind the inner window sill, with the
short side of bracket as shown. Use the 2 screws (TYPE A)provided.
b. The bracket helps to hold unit securely in place. Be sure toplace bracket edge flush against back of inner sill. SeeFigure.7.
HARDWARE
TYPE F: 1EA(SASH SEAL)
(Not adhesive backed)
TYPE E: 1EA(SEAL STRIP)
(Adhesive backed)
TYPE G: 2EA(GUIDE PANEL)
TYPE D: 3EA(L BACKET)
TYPE A: 14EA(SHORT SCREW)
10m
m
TYPE B: 2EA(WOOD SCREW)
16m
m
TYPE H: 1EA(UPPER GUIDE)
16m
m
TYPE C: 2EA(WOOD SCREW)
ROOM SIDE
CENTER LINE
INNER SILL
SEAL STRIP(TYPE E)
OUTSIDE
INSIDE
L BRACKET
OUTER SILLINNER SILL
TYPE A
7.5"7.5"
CENTER LINE
TYPE A
TYPE A
TYPE AFigure 4
Figure 5
Figure 6
Figure 7
Service Manual 11
CAUTION: During the following step, holdunit firmly until window sash is lowered totop channel behind side panel frames.Personal injury or property damage mayresult if unit falls from window.
3. Install the Air Conditioner in the Windowa. Carefully lift the air conditioner and slide it into the open win-
dow. Make sure the bottom guide of the air conditioner dropsinto the notches of the L bracket.
IMPORTANT :When the air conditioner drops into the L bracket, the airconditioner will be centered in window opening as shown inFigure. 8.
b. While steadying the air conditioner, carefully bring thewindow sash down behind the upper guide of the airconditioner, as shown in Figure. 9.
4. Secure the Guide PanelsExtend the guide panels (TYPE G) to fill the windowopening using 2 screws (TYPE B), 2 screws(TYPE C) tosecure them as shown in Figure. 10.
5. Install the Sash Seal and Sash Locka. Cut the sash seal (TYPE F) to the window width.
Stuff the sash seal between the glass and the windowto prevent air and insects from getting into the room,as shown in Figure. 10.
b. Fasten the L bracket using a (TYPE A) screw, asshown in Figure. 10.
6. Window installation of room air conditioner is nowcompleted. See ELECTRICAL DATA for attachingpower cord to electrical outlet.
In humid weather, excess water may cause the BASE PANto overflow. To drain the water, remove the DRAIN CAPand secure the DRAIN PIPE to the rear hole of the BASEPAN. (Figure. 11)
Press the drain pipe into the hole by pushing down andaway from the fins to avoid injury.
Installation
How to Secure the Drain pipe
hang push1 2
DRAIN PIPEDRAIN CAP
CENTER LINE
SEALWINDOW FRAME
BOTTOMGUIDE
ABOUT 1/4"
UPPER GUIDE
L BRACKET
L BRACKET
FOAM SEAL(TYPE F)
TYPE A
TYPE B
TYPE C
Figure 8
Figure 9
Figure 10
Figure 11
12 Room Air Conditioner
Operation
Feature
Insulation Resistance Test
About the Controls of the Air Conditioner
• DESIGNED FOR COOLING ONLY • POWERFUL AND INCREDIBLE COOLING• TOP-DOWN CHASSIS FOR THE SIMPLE INSTALLATION AND SERVICE• BUILT-IN ADJUSTABLE THERMOSTAT• WASHABLE ONE-TOUCH FILTER• COMPACT SIZE
1. Unplug the power cord and connect a jumper between 2 pins (black and white).
2. The grounding conductor (green or green and yellow) is to be open.
3. Measure the resistance value with an ohm meter between the jumpered lead and each exposed metallic parton the equipment at all positions [except Off] of the ROCKER SWITCH.
4. The value should be over 1 MΩ.
Operation
AutoSwing
Power
Temp
Fan Speed
Timer Mode
CAUTION: The Remote Controller will not function properly if stronglight strikes the sensor window of the air conditioner or if there areobstacles between the Remote Controller and the air conditioner.
�
1. FRONT GRILLE
1. Disconnect the unit from source of power.2. Using a screwdriver, remove the screw from the front
grille. (See Figure 13)3. Push the front grille up from the bottom.
Pull the top of the front grille away from the cabinet as thetop tabs lift out of their slots. (See Figure 14)
4. Replace the grille by placing the tabs in the slots andpush the grille until it snaps into place.
2. CABINET
1. Disconnect the unit from the power source.2. Remove the front grille. (Refer to section 1)3. Remove 10 screws that secure the cabinet to the base
pan and condenser. (See Figure 15)4. Lift the cabinet from the unit.5. Re-install by referring to the procedures above.
3. CONTROL PANEL
1. Disconnect the unit from the power source.2. Remove the front grille. (Refer to Section 1)3. Remove the cabinet. (Refer to Section 2)4. Remove 2 screws that secure the control panel to control
box and base pan. (See Figure 16)5. Pull the control board toward yourself.
Controls, wires, and capacitor are now accessi-ble for servicing. Discharge the capacitor beforeservicing.
6. Disconnect one housing terminal and 3 wires for the fanmotor and compressor. (See Figure 17)
7. Re-install components by referring to procedures above.(Refer to wiring diagram on page 19 in this manual or oncontrol box.)
NOTICE
NOTICE
Disassemblyly
Mechanical Parts
Disassembly
NOTICE
14 Room Air Conditioner
4. AIR GUIDE UPPER
1. Disconnect the unit from the power source.2. Remove the front grille. (Refer to Section 1)3. Remove the cabinet. (Refer to Section 2)4. Remove the control board. (Refer to Section 3)5. Remove tape that attached the air guide upper and
lower.6. Lift air guide upper upward. (See Figure 18)7. Re-install by referring to the procedures above.
5. ORIFICE, TURBO FAN AND FAN
1. Disconnect the unit from the power source.2. Remove the front grille. (Refer to Section 1)3. Remove the cabinet. (Refer to Section 2)4. Remove the control panel. (Refer to Section 3)5. Remove the air guide upper. (Refer to Section 4)6. Remove 2 screws that secure the condenser to the
base pan.7. Remove the screw that secures the shroud to channel
of condenser.8. Press the snap area of shroud with your thumbs. This
allows you to remove it from the condenser.9. Remove 1 screw that secure the evaporator to the base
pan. (See Figure 19)10. Remove the orifice by pushing the snap area of the air
guide blower. (See Figure 20)11. Remove the clamp springs which are clamped to the
boss of fan and turbo fan by hand plier.(See Figure 21)
12. Pull the fan and turbo fan outward. 13. Re-install by referring to the procedures above.
Disassembly
Air Handling Parts
Figure 19
Figure 18
Figure 20
Figure 21
Service Manual 15
Disassembly
6. MOTOR1. Disconnect the unit from the power source.2. Remove the front grille. (Refer to Section 1)3. Remove the cabinet. (Refer to Section 2)4. Remove the control panel. (Refer to Section 3)5. Remove the air guide upper. (Refer to Section 4)6. Remove the compressor, turbo fan, axial fan and
shroud. (Refer to Section 5)7. Remove 4 screws that secure the motor to the mount
motor of shroud. (See Figure 22)8. Remove the motor. 9. Re-install by referring to the procedures above.
7. AIR GUIDE LOWER AND SHROUD1. Disconnect the unit from the power source.2. Remove the front grille. (Refer to Section 1)3. Remove the cabinet. (Refer to Section 2)4. Remove the control panel. (Refer to Section 3)5. Remove the air guide upper. (Refer to Section 4)6. Remove the compressor, turbo fan, axial fan.
(Refer to Section 5)7. Remove the motor. (Refer to Section 6)8. Remove 2 screws that secure the shroud to the base
pan. (See Figure 23)9. Lift air guide lower and shroud upward.
(See Figure 23)10. Re-install by referring to the procedures above.
8. OVERLOAD PROTECTOR 1. Remove the front grille and cabinet.
(Refer to Section 1, 2)2. Remove the nut which fastens the terminal cover.3. Remove the terminal cover.4. Remove all the leads from the overload protector.5. Remove the overload protector.6. Re-install the components by referring to the
removal procedure above. (See Figure 24)
9. COMPRESSOR1. Remove the front grille and cabinet.
(Refer to Section 1, 2) 2. Discharge the refrigerant by using a refrigerant
recovery system.3. Remove the overload protector.
(Refer to Section 8)4. After discharging the unit completely, unbrace the
suction and discharge pipes at the compressor con-nections.
5. Remove 3 nuts which fasten the compressor.6. Remove the compressor.7. Re-install by referring to the removal procedure
above. (See Figure 25)
Electrical Parts
Figure 22
Figure 23
Figure 24
Figure 25
16 Room Air Conditioner
Disassembly Disassembly Disassembly Disassembly
le
le
R erating CycRefrigerating Cycle
10. CAPACITOR1. Remove the cabinet. (Refer to Section 2)2. Remove the control panel. (Refer to Section 3)3. Discharge the capacitor by placing a 20 K� resistor
across the capacitor terminals.4. Remove all the leads of capacitor terminals.5. Re-install the components by referring to the removal
procedure above. (See Figure 26)
11. THERMISTOR1. Remove the cabinet. (Refer to Section 2)2. Remove the control panel. (Refer to Section 3)3. Remove the main PCB inside the control box.4. Remove the thermostat.5. Re-install the components by referrig to the � temoval procedure above.
12. POWER CORD1. Disconnect the unit from source of power.2. Remove the front grille. (Refer to Section 1)3. Remove the cabinet. (Refer to Section .2)4.
box. (Refer to Section 3)5. Pull the power cord. (See Figure 29)6. Re-install by referring to procedures above.
1. Remove the cabinet. (Refer to Section 2)2. Discharge the refrigerant by using a refrigerant recovery
system.3. Remove 2 screws which fasten the condenser.
(See Figure 30)4. After discharging the refrigerant completely, unbraze the
interconnecting tube at the condenser connections.5. Remove the condenser.
6. Re-install by referring to the procedures above.
10. CAPACITOR1. Remove the cabinet. (Refer to Section 2)2. Remove the control panel. (Refer to Section 3)3. Discharge the capacitor by placing a 20 K� resistor
across the capacitor terminals.4. Remove all the leads of capacitor terminals.5. Re-install the components by referring to the removal
procedure above. (See Figure 26)
11. THERMISTOR1. Remove the cabinet. (Refer to Section 2)2. Remove the control panel. (Refer to Section 3)3. Remove the main PCB inside the control box.4. Remove the thermostat.5. Re-install the components by referrig to the � temoval procedure above.
1. Disconnect the unit from source of power.2. Remove the front grille. (Refer to Section 1)3. Remove the cabinet. (Refer to Section .2)4.
box. (Refer to Section 3)5. Pull the power cord. (See Figure 29)6. Re-install by referring to procedures above.
1. Remove the cabinet. (Refer to Section 2)2. Discharge the refrigerant by using a refrigerant recovery
system.3. Remove 2 screws which fasten the condenser.
(See Figure 30)4. After discharging the refrigerant completely, unbraze the
interconnecting tube at the condenser connections.5. Remove the condenser.
6. Re-install by referring to the procedures above.
10. CAPACITOR1. Remove the cabinet. (Refer to Section 2)2. Remove the control panel. (Refer to Section 3)3. Discharge the capacitor by placing a 20 K� resistor
across the capacitor terminals.4. Remove all the leads of capacitor terminals.5. Re-install the components by referring to the removal
procedure above. (See Figure 26)
11. THERMISTOR1. Remove the cabinet. (Refer to Section 2)2. Remove the control panel. (Refer to Section 3)3. Remove the main PCB inside the control box.4. Remove the thermostat.5. Re-install the components by referrig to the � temoval procedure above.
1. Disconnect the unit from source of power.2. Remove the front grille. (Refer to Section 1)3. Remove the cabinet. (Refer to Section .2)4.
box. (Refer to Section 3)5. Pull the power cord. (See Figure 29)6. Re-install by referring to procedures above.
1. Remove the cabinet. (Refer to Section 2)2. Discharge the refrigerant by using a refrigerant recovery
system.3. Remove 2 screws which fasten the condenser.
(See Figure 30)4. After discharging the refrigerant completely, unbraze the
interconnecting tube at the condenser connections.5. Remove the condenser.
6. Re-install by referring to the procedures above.
10. CAPACITOR1. Remove the cabinet. (Refer to Section 2)2. Remove the control panel. (Refer to Section 3)3. Discharge the capacitor by placing a 20 K� resistor
across the capacitor terminals.4. Remove all the leads of capacitor terminals.5. Re-install the components by referring to the removal
procedure above. (See Figure 26)
11. THERMISTOR1. Remove the cabinet. (Refer to Section 2)2. Remove the control panel. (Refer to Section 3)3. Remove the main PCB inside the control box.4. Remove the thermostat.5. Re-install the components by referrig to the � temoval procedure above.
1. Disconnect the unit from source of power.2. Remove the front grille. (Refer to Section 1)3. Remove the cabinet. (Refer to Section .2)4. Remove a screw that secures control panel to control
box. (Refer to Section 3)5. Pull the power cord. (See Figure 29)6. Re-install by referring to procedures above.
13. CONDENSER1. Remove the cabinet. (Refer to Section 2)2. Discharge the refrigerant by using a refrigerant recovery
system.3. Remove 2 screws which fasten the condenser.
(See Figure 30)4. After discharging the refrigerant completely, unbraze the
interconnecting tube at the condenser connections.5. Remove the condenser.
6. Re-install by referring to the procedures above.
Figure 26
Figure 27
Figure 29
Figure 30
Service Manual 17
Disassembly
15. EVAPORATOR1. Remove the cabinet. (Refer to Section 2)2. Discharge the refrigerant by using a refrigerant
recovery system. 3. Remove the air guide upper.
(Refer to Section 4)4. After discharging the refrigerant completely,
unbraze the interconnecting tube at the evapo-rator connections.
5. Remove the evaporator.6. Re-install by referring to the procedures above.
16. CAPILLARY TUBE1. Remove the cabinet. (Refer to Section 2)2. Discharge the refrigerant by using a refrigerant
recovery system.3. Remove the air guide upper.
(Refer to Section 4)4. After discharging the refrigerant completely,
unbraze the interconnecting tube of the capil-lary tube.
5. Remove the capillary tube.6. Re-install by referring to the procedures above.
Replacement of the refrigeration cycle.
1. When replacing the refrigerating cycle, be sure todischarge the refrigerant by using a refrigerantrecovery system.
2. After discharging the unit completely, remove thedesired components, and unbraze the pinch-offtubes.
3. Solder service valves into the pinch-off tube ports,leaving the valves open.
4. Solder the pinch-off tubes with service valves. 5. After completing the above procedures, the valve
must be closed and left in place on the system forany subsequent procedures.
6. Evacuate as follows: 6-1. Connect the vacuum pump, as illustrated in
figure 31A. 6-2. Start the vacuum pump. Slowly open manifold
valves A and B with two full turns counter-clockwise and leave the valves closed. The vacuum pump is now pulling throughvalves A and B up to valve C by means ofmanifold and the entire system.
CAUTION: If high vacuum equip-ment is used, just crack valves Aand B for a few minutes, then open
slowly with the two full turnscounter-clockwise. This will keep oilfrom foaming and being drawn intothe vacuum pump.
6-3. Operate the vacuum pump for 20 to 30 minutes,until 600 micron vacuum is obtained. Close valves A and B and observe vacuumgauge for a few minutes. A rise in pressure would indicate a possible leakor moisture remaining in the system. With valves A and B closed, stop the vacuumpump.
6-4. Remove the hose from the vacuum pump andplace it on the charging cylinder. See figure 20B.Open valve C. Discharge the line at the manifold connection.
6-5. The system is now ready for final charging.
7. Recharge as follows: 7-1. Rotary compressor systems are charged from
the high-side. If the total charge cannot be putin the high-side, the balance will be put in thesuction line through the access valve which isinstalled as the system is opened.
7-2. Connect the charging cylinder as shown in fig-ure 31B. With valve C open, discharge thehose at the manifold connection.
7-3. Open valve A and allow the proper charge toenter the system. Valve B is still closed.
7-4. If more charge is required, the high-side willnot take it. Close valve A.
7-5. With the unit running, open valve B and addthe balance of the charge. a. Do not add the liquid refrigerant to the low-
side. b. Watch the low-side gauge, allow pressure to
rise to 30 lbs(0.2MP). c. Turn off valve B and allow the pressure to
drop. d. Repeat steps B and C until the balance of
the charge is in the system. 7-6. When the unit is operating correctly, use the
pinch-off tool with the unit still running and theclamp on the pinch-off tube. Using a tube cut-ter, cut the pinch-off tube about 2 inches fromthe pinch-off tool. Use sil-fos solder and solderthe pinch-off tube closed. Turn off the unit,allow setting for a while and then test the leak-age of the pinch-off connection.
NOTICE
18 Room Air Conditioner
Disassembly
Equipment needed: Vacuum pump, charging cylinder, manifold gauge, brazing equipment, pinch-off tool capableof making a vapor proof seal, leak detector, tubing cutter, hand tools to remove components and service valve.
BA
B A
B A
COMPOUND GAUGE
SEE INSETSBELOW
CAPILLARY TUBE
EVAPORATOR(LOW PRESSURE SIDE)
COMPRESSOR
CONDENSER(HIGH PRESSURE SIDE)
EXTERNAL VACUUM PUMP
LO HI CHARGING CYLINDER
MANIFOLDGAUGE
C
Figure 31A-Pulling Vacuum Figure 31B-Charging
Service Manual 19
Schematic Diagram
Schematic DiagramCircuit Diagram
DESCRIPTION & NAME
FAN MOTOR
MAIN PCB
DISPLAY
TERMITOR
COMPRESSOR
POWER CORD ASSY
CAPACITOR
OVERLOAD PROTECTOR
Q'TY
1
1
1
1
1
1
1
1
REF. NO
1
2
3
4
5
6
7
8
20 Room Air Conditioner
WP
Vcc
Dig
it3 (S
can3
)
Dig
it4 (S
can4
)
Dig
it1 (S
can1
)
Dig
it2 (S
can2
)
Dig
it0 (S
can0
)
MA
IN P
OW
ER
CO
MP
HE
RM
FAN
C
CA
PA
CIT
ORM
OTO
RFA
N
120
1/2W
ZNR
01J
SV
C27
1D-1
4A
250V
/T2A
FUS
E
G4A
-1A
-E-L
GR
Y-C
OM
P
1000
D02
D~D
05D
1N40
0435
V
D03
D
D02
D
PO
WE
R T
RA
NS
1 2
7 4
D05
D
+D
04D C01
D
R01
J
CN
-WO
R
C01
J0.
1/27
5V
CN
-BK
CN
-BL
CN
-RD
RY
-HI
RY
-LO
W
RY
-ME
D
C06
D5V
0.01
0.1
50V
16V
1000
10V
0.01
50V
50V
C04
D
12V
IC01
D C03
DC
02D78
12O
I
+22
0C
05D
OIC
02D
7805
+
IC
01L
680p
F
1K
ULN
2004
AIC
01G
R01
L
5V
1KR
01E
20R
02E
20K
R12
F
10K
R02
F0.
001
C02
FR
01F
10K
C01
F0.
001
RO
OM
-TH
PIP
E-T
H
SY
NC
S/V
-4W
AY
MO
TOR
314
RY
-SY
NC
RY
-4W
AY
CN
-4W
AY
11
331
1
CN
-SY
NC
33
12V
RY
-HI
RY
-ME
D
ULN
2004
AIC
01M
915 16
82 1
12V
443
2
OR
1H
RY
-SY
NC
RY
-LO
W
RY
-4W
AY
RY
-CO
MP
11 12 13
6 5 4
107
OR
2H
5V
12.1
KR
21H
R03
H0K
12.1
K1%
1%R22
H
HV
B
KEY1
LED out2
LED out1
LED out0
3435
36
LED
out
3
Rec
eive
r30
Buz
zer
333231
HI
ME
D
ION
292827
SLIDE SW
40
KEY0
3738
39
VDD
SEG-g4142
43
SEG-f
SEG-e
44 SEG-d
TMP
87C
H47
UM
ICO
M
4
SE
G-b
SE
G-a
SE
G-c
3 2 17 6 5
Room TH
Option2
Option1
Pipe TH
23 262524S
YN
C
LOW
4WA
Y
CO
MP
2021
22
/Reset
Osc out
Osc in
16
VAref
VSS
1819
1713
1415
TEST
11
SC
L
SD
A10 9 8
Tx
12R
x
5VA
13 4
GN
DS
DA
SC
LA
2
A0
1 2
EE
PR
OM
CA
T93C
46
SM
W25
0-02
11 2
2
CN
-TH
1
5V
R01
B
R02
HR
01H
1%6.2K
1%12.1
KR
T8.0
0MG
1M
OS
C01
B
50V
C01
A0.
01+
C02
A1u
F10
V
3
20K
R01
A
610
AIR
PU
RIF
IER
220
R07
G7
108
912
V
162
12 1536
220
220
220
220
220
R03
G3
14
512
611
413
R05
G
R06
G
220
R04
G
116
215
R01
G
R02
G
1110
78
98
910A
/RE
STA
RT
126 7
11
1413
45
A/S
WIN
G
gE
/SA
VE
R
+88 S
EG
ME
NT
GN
D
RE
CE
IVE
R
BZ0
1E
-400
2P
KM
13E
PY
Vou
t
Vcc
8
10V
5V
220
C22
L
dd
DE
FRO
ST
fc
FAN
DR
Y/H
EA
T
TIM
ER
71e
fe23
d
CO
OL
45bD
igit1
a
bf
b cc
e
gg
aa
Dig
it0
5V
5V17 1
171
D03
F5V
EN
ER
GY
SA
VE
RS
W3
D07
F
TEM
P U
P SW7
1KR04
P
6 5
20K
20K
R02
P8 7
R03
P5V
A10
1S
D02
F
TIM
ER
SW
2
D01
F
FAN
SW
1
TEM
P D
OW
N
D05
F
SW
5
MO
DE
D04
F
SW
4
D08
F
AU
TO S
WIN
G
SW
8
SW
6
ON
/OFF
D06
F
1442 16
3 15
A10
1SQ
03G
A10
1SQ
02G
5 13
Q01
GA
101S
1
IC01
AS
7136
2
3.6V
5V
Q04
G
CN
-DIS
PC
N-D
ISP
Electronic Control Device
Schematic Diagram
Service Manual 21
Components Location (For Main P.W.B ASM)
Trouleshooting Glwide
22 Room Air Conditioner
Troubleshooting Guide
Troubleshooting GuidePiping System
Following is a brief description of the important components and their function in what is called the refrigerationsystem. Reference should be made to Figure 32 to follow the refrigerating cycle and the flow of the refrigerant inthe cooling cycle.
COOLEDAIR
HOTDISCHARGEDAIR
MOTOR
COMPRESSOR
ROOM AIR HEAT LOAD
CAPILLARY TUBE
(LIQUID REFRIGERANT)
LIQUID OUTLET
VAPOR INLETCOMPLETE LIQUIDBOIL OFF POINT
SUCTION LINECOOL LOW PRESSURE VAPOR
LIQUID PRESSUREDROP
DISCHARGELINE
NOT HIGH PRESSUREVAPOR
OUTSIDE COOLINGAIR FOR REFRIGERANTPASS THROUGH
EVAPORATOR COILS CONDENSER COILS
ROOM AIR CONDITIONERCYCLE OF REFRIGERATION
HIGH PRESSURE VAPOR
LIQUID REFRIGERANT
LOW PRESSURE VAPOR
OIL
CONDENSER COILS
FAN
MOTORCAPILLARY TUBE
TURBO FAN
EVAPORATORCOILS
Figure 32
Service Manual 23
Troubleshooting Guide
Troubleshooting GuideIn general, possible trouble is classified in two kinds. The one is called Starting Failure which is caused by an electrical defect. The other is Ineffective Air Conditioningcaused by a defect in the refrigeration circuit and improper application.
Unit is running but cooling is ineffective.
Ineffective Cooling
Satisfactory operationwith temperature difference of inlet & outletair; 44~50°F (7~10°C)
Replacement of unit if the unit is beyond repair.
Check outdoor coil (heat exchanger) andfan operation.
Check heat load increase.
Check cold air circulation for smooth flow.
Check gas leakage. Clean condenser.
Not on separate circuit
Check inside gas pressure.
Adjust refrigerant charge.
Malfunction of compressor.
Replacement of compressor.
Check clogging in refrigera-tion circuit.
Repair clogging in refrigeration circuit.
Dirty indoor coil (heat exchanger)
Repair gas leak. Malfunction of fan.
Clogging of air filter.
Obstruction at air outlet.
Remove obstruction.
24 Room Air Conditioner
Troubleshooting Guide
Fails to Start
Improper thermostat setting
Loose terminal connection
Improper wiring
Check of power source.
Drop of power voltage.
Capacitor check.
Replacement.
Check of control switch setting.
Compressor fails only to start.
Defect of compressor capacitor.
Replacement of compressor (Motor damaged).
Irregular motor insulation (Ω)
Irregular motor resistance (Ω)
Check of circuit breaker and fuse.
Gas leakage of feeler bulb of thermostat.
Check control switch.
Fan only fails to start.
Improper wiring.
Defect of fan motor capacitor.
Replacement of fan motor.
Regular but fails to start.
Replacement of compressor. (Locking of piston, metal.)
Irregular motor resistance (Ω)Irregular motor insulation (Ω)
Service Manual 25
Troubleshooting Guide
ELECTRIC PARTS TROUBLESHOOTING GUIDE:
Possible Trouble 1 • The unit does not operate.
Is the Trans input powerAC 115V?
Is the Trans output powerabout AC 14V?
Is shorted the Trans. output?
Is output Voltage of IC01DDC 12V?
Is output Voltage of IC02DDC 5V?
Is the voltage No.18 of MicomDC 5V?
Exchange Main P.W.B Ass'y.
Is the connection between
Main and Display all right?
Is the reset circuit all right?(The No.14 of Micom
is 5V.)
• Check the Fuse.• Check the wiring diagram.
• Check the Main P.W.B pattern.
• Exchange the Trans.
• Exchange D02D~D05D.• Exchange IC01D.
• Exchange IC02D.
• Exchange IC01A.
• Connect connector exactly.
• Check the P.W.B pattern.
NO
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
YES
NO
YES
26 Room Air Conditioner
Troubleshooting Guide
Is Temp.setting set lower than Room
Temp.-0.5°C?
Is the voltage No.10of IC01M 0V?
• Exchange IC01M.
• Set the Temp. setting to lower Temp.
• Wait 3 Minutes
Is the Unit for 3 minutesdelay?
• Exchange MAIN P.W.B Ass'y.
Is the voltage N0.7 of IC01M DC 5V?
• Check the RY-COMP.• Check the wiring Diagram.
NO
NO
NO NO
YES YES
YES
YES
Possible Trouble 2 • The compressor does not operate.
Is the wire connection of RY-COMP all right?
• Check the RY-COMP.
• Connect LEAD Wire to RY-COMP again.
NO
YES
Possible Trouble 3 • The compressor always operate.
• Exchange IC01M.
• Exchange IC01M.
Is the voltage NO.1 or 4of IC01M DC 5V?
Is the voltage NO.13 or 16of IC01M 0V?
• Check the RY-Hi orRY-Lo.
• Check the wiring diagram.
NO
NO
YES
YES
Possible Trouble 4 • Fan does not operate.
Service Manual 27
Troubleshooting Guide
Is the voltage of Batteryabout over 2.3V?
• Exchange Receiver Ass'y.
Is the connection of CN-DISP1 all right?
Is the voltage No.16 of CN-DISP1 on Main P.W.B
Ass'y DC 5V?
• Exchange the battery.
• Check the P.W.B pattern.
• Connect connector to CN-DISP1 exactly.
NO
NO
NO
YES
YES
YES
Possible Trouble 5 • Romote controller does not operate.
NO
NO
NO
NO
YES
YES
YES
Is the IC01G all right?
Is the connection of CN-DISP1 all right?
• Exchange the display P.W.B Ass'y.
• Exchange IC01G.
• Exchange Q01G, Q02G, Q03G, Q04G
• Connect connector to CN-DISP1 exactly.
Does the Q01G,Q02G, Q03G Q04G operate normally
on main P.W.B Ass'y?
Possible Trouble 6 • It displays abnormally on Display P.W.B Ass'y.
28 Room Air Conditioner
Troubleshooting Guide
Room Air Conditioner Voltage Limits
NAME PLATE RATING MINIMUM MAXIMUM
115V ± 10% 103.5V 126.5V
COMPLAINT CAUSE REMEDY
Fan motor will not run. No power Check voltage at outlet. Correct if none.
Power supply cord Check voltage to rotary switch. If none, check power supply cord. Replace cord if circuit is open.
Rocker switch Check switch continuity. Refer to wiring diagram for terminal identification. Replace switch if defective.
Wire disconnected or Connect wire. Refer to wiring diagram for connection loose terminal identification. Repair or replace loose
terminal.
Capacitor (Discharge Test capacitor. capacitor before testing.) Replace if not within ±10% of manufacturer's
rating. Replace if shorted, open, or damaged.
Will not rotate Fan blade hitting shroud or blower wheel hitting scroll. Re-align assembly.
Units using slinger ring condenser fans must have 0.22~0.25 inch clearance to the base. If necessary, shim up the bottom of the fan motor with mounting screw(s).
Check fan motor bearings; if motor shaft will not rotate, replace the motor.
Fan motor runs. Revolves on overload Check voltage. See limits on this page.
If not within limits, call an electrician.
Test capacitor. Check bearings. Does the fan blade rotate
freely? If not, replace fan motor.
Pay attention to any change from high speed to low speed. If the speed does not change, replace the motor.
Service Manual 29
Troubleshooting Guide
COMPLAINT CAUSE REMEDY
Fan motor noise. Tubo Fan If cracked, out of balance, or partially missing, replace it.
Axial Fan If cracked, out of balance, or partially missing, replace it.
Loose set screw Tighten it.
Worn bearings If knocking sounds continue when running or loose, replace the motor. If the motor hums or noise appears to be internal while running, replace motor.
Compressor will not run, Voltage Check voltage. See the limits on the preceding fan motor runs. page. If not within limits, call an electrician.
Wiring Check the wire connections; if loose, repair or replace the terminal. If the wires are discon-nected, refer to wiring diagram for identification, and replace the wires. Check the wire connections; If not according to the wiring diagram, correct the connections.
Rocker Switch Check for continuity, refer to the wiring diagram for terminal identification. Replace the switch if the circuit is open.
Thermostat Check the position of knob. If not at the coldest setting, advance the knob to this setting and restart the unit.
Check the continuity of the thermostat. Replace the thermostat if the circuit is open.
Capacitor (discharge Check the capacitor. capacitor before Replace if not within ±10% of manufacturer’s servicing.) rating, replace if shorted, open, or damaged.
Compressor Check the compressor for open circuit or ground. If open or grounded, replace the compressor.
Overload Check the compressor overload if externally mounted.Replace if open. (If the compressor temperature is high, remove the overload, cool, and retest.)
Compressor cycles on Voltage Check the voltage. See the limits on the overload. preceding page. If voltage is not within these limits,
call an electrician.
Overload Check overload, if externally mounted. Replace if open. (If the compressor temperature is high, remove the overload, cool, and retest.)
30 Room Air Conditioner
Troubleshooting Guide
COMPLAINT CAUSE REMEDY
Compressor cycles on Fan motor If not running, determine the cause. Replace if overload. required.
Condenser air flow Remove the cabinet, inspect the interior surface restriction of the condenser. If restricted, clean carefully
with a vacuum cleaner (do not damage fins) or brush. Clean the interior base before re-assembling.
Condenser fins If the condenser fins are closed over a large (damaged) area on the coil surface, head pressures will
increase, causing the compressor to cycle. Straighten the fins or replace the coil.
Capacitor Test the capacitor.
Wiring Check the terminals. If loose, repair or replace.
Refrigeration system Check the system for a restriction.
Insufficient cooling Air filter If restricted, clean or replace.
Unit undersized Determine if the unit is properly sized for the area to be cooled.
Excessive noise Turbo Fan or Axial Fan Check the set screw, or clamp. If loose or miss-ing, correct. If the tubo fan or axial fan is hitting scroll or barrier, rearrange the air handling parts.
Copper tubing Remove the cabinet and carefully rearrange the tubing not to contact the cabinet,compressor, shroud, and barrier.
Service Manual 31
Exploded View
Exploded View
B A E
C
D
352115
349480
352113
35211A
567502
554160
550140
352410
130410
W48602
148000
130910
559010
552113
554030
152302
159900-1
159900-1159900-2
352380-1
352380-2
135312
249950
359012
149980
346811
731373
W48602
AutoSwing
Power
Temp
Fan Speed
Timer Mode
32 Room Air Conditioner
Replacement Parts ListReplacement Parts List
130410 BASE ASSEMBLY, SINGLE 3 0 4 1 A 1 0 0 4 0 A130910 CABINET ASSEMBLY, SINGLE 3 0 9 1 A 1 0 0 5 5 A135312 GRILLE ASSEMBLY, FRONT(SINGLE) 3 5 3 1 A 1 1 0 1 0 A
148000 BRACE 4 8 0 0 A 3 0 0 1 2 A149980 SHROUD 4 9 9 8 A 1 0 0 2 8 A152302 FILTER(MECH), A/C 5 2 3 1 A R 9 0 0 1 B
159900-1 VANE, VERTICAL 4 7 5 8 A 3 0 0 4 1 A159900-2 VANE, VERTICAL 4 7 5 8 A 3 0 0 4 1 B
249950 CONTROL BOX ASSEMBLY 4 9 9 5 A 2 0 3 7 8 B
237200 PANEL,CONTROL 3 7 2 0 A 3 0 0 7 6 A238210 ESCUTCHEON 3 8 3 1 A 1 0 0 3 8 C
263230 THERMISTOR ASSEMBLY 6 3 2 3 A 2 0 0 0 4 R
264110 POWER CODE ASSEMBLY 6 4 1 1 A 2 0 0 3 8 A267110 REMOTE CONTROLLER 6 7 2 7 A Q 9 1 4 2 P238712 PWB(PCB)ASEMBLY,DISPLAY 6 8 7 1 A 2 0 4 4 9 A268714 PWB(PCB)ASSEMBLY,MAIN 6 8 7 1 A 1 0 1 2 9 A
346811 MOTOR ASSEMBLY, SINGLE 4 6 8 1 A 2 0 1 1 6 E349480 ORIFICE 4 9 4 8 A 2 0 0 3 1 B352113 TUBE ASSEMBLY, DISCHARGE 5 2 1 1 A 2 1 1 3 6 A352115 TUBE ASSEMBLY, EVAPORATOR IN 5 2 1 1 A 2 5 0 1 9 A35211A TUBE ASSEMBLY, SUCTION SINGLE 5 2 1 1 A 2 1 2 2 8 B
352380-1 AIR GUIDE 5 2 3 8 A 1 0 0 2 6 A352380-2 AIR GUIDE 5 2 3 8 A 1 0 0 2 5 A352410 EVAPORATOR ASSEMBLY, FIRST 5 4 2 1 A 2 0 1 7 6 C359012 FAN TURBO 5 9 0 0 A 2 0 0 4 0 B550140 ISOLATOR, COMPRESSOR 5 0 4 0 A R 4 1 9 5 A554030 CONDESER ASSEMBLY, FIRST 5 4 0 3 A 2 0 1 7 4 A554160 COMPRESSOR 2 5 2 0 U C A A 0 1 1559010 FAN, AXIAL 5 9 0 0 A 2 0 0 4 2 A567502 O.L.P 6 7 5 0 U - L 0 5 0 AW0CZZ CAPACITOR, DRAWING 0 C Z Z A 2 0 0 0 5 BW48602 CLAMP, SPRING 3 H 0 2 9 3 2 B
LOCATIONNO.
P A R T N O .W G 5 0 0 4 R
REMARKDESCRIPTION
Service Manual 33
P/No.: 3828A20472DFebruary, 2004
Printed in China