7
ROOFING ENVIRONMENTAL PRODUCT DECLARATION SARNAFIL G410

ROOFING ENVIRONMENTAL PRODUCT DECLARATION · PDF file3 Insulation 4 Insulation Fastener ... of products and systems for the construction and motor vehicle ... Environmental Product

Embed Size (px)

Citation preview

Page 1: ROOFING ENVIRONMENTAL PRODUCT DECLARATION · PDF file3 Insulation 4 Insulation Fastener ... of products and systems for the construction and motor vehicle ... Environmental Product

ROOFINGENVIRONMENTAL PRODUCT DECLARATIONSARNAFIL G410

Page 2: ROOFING ENVIRONMENTAL PRODUCT DECLARATION · PDF file3 Insulation 4 Insulation Fastener ... of products and systems for the construction and motor vehicle ... Environmental Product

1 Structural Deck

2 Vapor Retarder (if required)

3 Insulation

4 Insulation Fastener

5 Membrane Adhesive

6 Sarnafil G Membrane

COMPANY Sika Corporation — Roofing

PRODUCT TYPE Single Ply Roofing Membrane

PRODUCTSarnafil G410 roofing membrane, with a finished thickness of 48 mils, 60 mils, 72 mils or 80 mils.

MANUFACTURING SITE Canton, MA 02021

EPD SCOPE n Cradle-to-gate

EPD LIMITATIONSn EPDs from different programs (using different PCR) may not

be comparablen Declarations based on the ASTM SPRM PCR [1] are not

comparative assertions; that is, no claim of environmental superiority may be inferred or implied for cradle to gate declarations.

DECLARED UNIT 1m2 manufactured, Sarnafil G410

STANDARDS The four declared Sarnafil G410 roofing membrane thicknesses (48, 60, 72 and 80 mils) meet the following standards and requirements

n ASTM D4434n ENERGY STAR® Listed*n Title 24 Compliant* n Cool Roof Rating Council® Listed* n FM Approval n Miami-Dade County Approvaln Underwriters Laboratory Inc. n Underwriters Laboratories of Canadan NSF/ANSI 347 Sustainability Assessment

for Single Ply Roof Membranes

GENERAL INFORMATION

*white, tan, light gray only

ORGANIZATION Sika Corporation, based in Lyndhurst, NJ, is a leading manufacturer of products and systems for the construction and motor vehicle markets.

Sika Corporation’s roofing division has more than 50 years of experience manufacturing high quality, thermoplastic (PVC), single-ply roofing and waterproofing systems for the non-residential market. Sika is also the only roofing manufacturer to be rated “Platinum” according to NSF/ANSI 347, the leading consensus sustainability standard.

PRODUCT DESCRIPTION AND USEWith a track record of performance of over 50 years, Sarnafil roofing membranes are the products of choice for architects, specifiers and building owners who want the peace of mind that comes with buying from the performance leader.

Sarnafil G410 roof membrane is a thermoplastic PVC membrane used in adhered systems. Sarnafil G410 is fiberglass reinforced, offering exceptional dimensional stability and a low coefficient of thermal expansion suitable for adhering the membrane to the roof substrate. A unique lacquer coating is applied to the top surface of the membrane which helps to reduce soiling.

Sika’s Thickness Guarantee Program for all Sarnafil branded membranes guarantees they meet or exceed the labeled thickness, rather than following industry standards, which allows for membranes to be manufactured up to 10% below advertised thickness.

MEMBRANE

THICKNESSGUARANTEE

Page 3: ROOFING ENVIRONMENTAL PRODUCT DECLARATION · PDF file3 Insulation 4 Insulation Fastener ... of products and systems for the construction and motor vehicle ... Environmental Product

PRODUCT SPECIFICATIONS

TECHNICAL DATA UNITS ASTM TEST METHOD

ASTM D4434 TYPE III

REQUIREMENT

VALUE/TEST RESULTS

48 MILS 60 MILS 72 MILS 80 MILS

Weight [kg/m2 ] — — 1.5 1.8 2.3 2.5

Total Recycled Content (both pre— and post—consumer)3 [%] — — 103

Reinforcing Material — — — Fiberglass mat

Overall Thickness [mil] D751 45 48 60 72 80

Reflectivity [%] ASTM C1549 — 0.834 - 0.705

Emissivity [%] ASTM C1371 — 0.904 - 0.865

Solar reflective index (white) — — — 1044 - 855

Breaking Strength (M.D.), min. [lbf/in]. (KN/m) D751 55 (245) 60 (267) 80 (356) 100 (445) 110 (489)

Elongation at Break, min — D751 —

Machine Direction [%] 250 250 250 250 250

Cross Direction [%] 220 250 220 220 220

Seam Strength, min., (% of original)6 [%] D751 75 Pass

Retention of Properties After Heat Aging [%] D3045 — —

Tensile Strength, min., (% of original) [%] D751 90 Pass

Elongation, min., (% of original) [%] D751 90 Pass

Tearing Strength (C.D.), min [lbf] (N) D1004 10 (45) 15 (68) 17.5 (78) 20.5 (91) 22 (98)

Low Temperature Bend, —40 °F (—40 °C) — D2136 Pass Pass

Accelerated Weathering Test (Fluorescent Light, UV exposure) — G154 5,000 hours 10’000 hours

Cracking (7x magnification) None None None

Discoloration (by observation) Negligible Negligible Negligible

Crazing (7x magnification) None None None

Linear Dimensional Change (C.D.), % D1204 0.5% max. —0.02 —0.02 -0.01 —0.01

Weight Change After Immersion in Water, % D570 ±3.0% max. 2.4 1.9 1.8 1.7

Static Puncture Resistance, 33lbf (15 kg) D5602 Pass Pass Pass

Dynamic Puncture Resistance, 14.7 ft—lbf (20 J) D5635 Pass Pass Pass

3 Pre-consumer material: roofing membrane trimmings from Sika’s manufacturing process and market supplied post-industrial PVC scrap material. Post-consumer material: post-consumer Sika Sarnafil scrap material and old roofs (10% minimum content)

4 New Membrane5 3 year aged membrane6 Failure occurs through membrane rupture not seam failure

Page 4: ROOFING ENVIRONMENTAL PRODUCT DECLARATION · PDF file3 Insulation 4 Insulation Fastener ... of products and systems for the construction and motor vehicle ... Environmental Product

MATERIAL CONTENT DECLARATION The material average percentage by weight for 1m2 for the Sarnafil G410 48, 60, 72 and 80 mils is provided.

MATERIAL AVERAGE PERCENTAGE BY WEIGHT FOR 1M2: SARNAFIL G410 48, 60, 72 AND 80 [MILS] PACKAGING MATERIAL DECLARED PRODUCT [MILS]

Raw Material Input Total Weight by [%] 48 60 72 80Lacquer 0.1

Cardboard Core [kg] 0.05 0.05 0.05 0.05PVC Resin new material 42.8

PVC Resin recycled content 13.8Wooden Pellet [kg] 0.13 0.13 0.22 0.22

Plasticizer 28.0

PE Film [kg] 0.005 0.005 0.006 0.006Processing aid 0.2

Stabilizer 2.1

Fire retardants 7.7

Total [kg/m2] 0.18 0.18 0.27 0.27Pigment 2.9

Fiberglass mat 2.3

Total weight (Input) 100

SYSTEM BOUNDARY

A1-A3

INCLUDED EXCLUDED

• Extraction and processing of raw materials, including fuels used in product manufacturing;• Transportation of raw materials including empty backhauls; • Manufacturing of the product;• Packaging of product ready for shipment;• Transportation from manufacturing site to recycling/reuse for pre-consumer wastes and

unutilized by-products from manufacturing, including empty backhauls; and • Recycling/reuse of pre-consumer wastes and by-products of production.

Capital goods & infrastructure, production equipment, delivery vehicles, lab equipment personnel-related activities and energy and water use related to company management and sales have been excluded in the scope of the study

END OF LIFE STAGEIncluded in System Boundary

C1: De-construction/DemolitionC2: TransportC3: Waste ProcessingC4: Disposal

Life Cycle Stages

PRODUCT STAGEIncluded in System Boundary

A1: Raw Material SupplyA2: TransportA3: Manufacturing

USE STAGEModule not declared,exclude from the System Boundary

B1: UseB2: MaintenanceB3: RepairB4: ReplacementB5: RefurbishmentB6: Operational Energy UseB7: Operational Water Use

CONSTRUCTION STAGEIncluded in System Boundary

A4: TransportA5: Construction/Installation Process

1

23

4

PRODUCT STAGEIncluded in System Boundary

A1: Raw Material SupplyA2: TransportA3: Manufacturing

Life Cycle Stages

END OF LIFE STAGEModule not declared,exclude from the System Boundary

C1: De-construction/DemolitionC2: TransportC3: Waste ProcessingC4: Disposal

CONSTRUCTION STAGEModule not declared,exclude from the System Boundary

A4: TransportA5: Construction/Installation Process

4

USE STAGEModule not declared,exclude from the System Boundary

B1: UseB2: MaintenanceB3: RepairB4: ReplacementB5: RefurbishmentB6: Operational Energy UseB7: Operational Water Use

32

1

STAGES INCLUDED IN LIFE CYCLE ASSESSMENT (LCA)

STAGES EXCLUDE FROM LCA

STAGES INCLUDED IN THIS LIFE CYCLE ASSESSMENT (LCA)

STAGES EXCLUDED FROM LCA

Page 5: ROOFING ENVIRONMENTAL PRODUCT DECLARATION · PDF file3 Insulation 4 Insulation Fastener ... of products and systems for the construction and motor vehicle ... Environmental Product

LIFE CYCLE IMPACTS

RESULTS SARNAFIL G410 DECLARED PRODUCT

CATEGORY INDICATOR 48 MILS 60 MILS 72 MILS 80 MILS

Global Warming Air, incl. biogenic carbon [kg CO2-eq.] 4.57 5.68 6.82 7.58

Acidification potential [kg SO2-Equiv.] 4.42E-02 5.51E-02 6.61E-02 7.35E-02

Eutrophication potential [kg N-Equiv.] 7.93E-04 9.84E-04 1.18E-03 1.32E-03

Smog creation potential [kg O3-Equiv.] 0.285 0.356 0.425 0.471

Ozone Depletion Potential [kg ethene-eq.] 5.827E-08 7.300E-08 8.770E-08 9.748E-08

TOTAL PRIMARY ENERGY CONSUMPTION

Nonrenewable fossil [MJ] 111.90 139.34 167.03 185.47

Nonrenewable nuclear [MJ] 5.74 7.08 8.46 9.37

Renewable (solar, wind, hydropower, geothermal) [MJ] 1.61 1.96 2.33 2.58

Renewable (biomass) [MJ] 0.02 0.02 0.02 0.022

MATERIAL RESOURCES CONSUMPTION

Nonrenewable materials [kg] 1.33 1.67 2.05 2.23

Renewable materials [kg] 0.18 0.18 0.27 0.27

Fresh water [l] 16.08 19.45 22.98 25.31

WASTE GENERATED

Total [kg] 0.28 0.34 0.41 0.45

Additional Environmental Information

n Sarnafil roofing membranes were the first, and at the time of printing the only, products to achieve platinum certification to the NSF/ANSI 347 Sustainability Assessment for Single Ply Roofing Membranes.

n The Sarnafil EnergySmart® membrane has a highly reflective, lacquer-coated surface that can reduce cooling and overall energy consumption in conditioned buildings. Sarnafil roof membranes exceed the cool roof requirements of ENERGYSTAR,® California’s Building Energy Code (Title 24), LEED® and Green Globes.™

n Sika Roofing’s Roof Recycling Program has diverted more than 45 million pounds of pre-consumer and post-consumer vinyl membrane from landfill, recycling it back into roofing and waterproofing membrane products.

n Sarnafil 5’ and 10’ membranes have been validated by UL Environment to contain an average of 10% recycled content.

n Sika roofing has been certified as compliant with strict environment, health and safety, and security standards established by the Responsible Care and ISO 14001: 2004.

n Sarnafil roof membranes help building owners achieve LEED and Green Globes certification

Page 6: ROOFING ENVIRONMENTAL PRODUCT DECLARATION · PDF file3 Insulation 4 Insulation Fastener ... of products and systems for the construction and motor vehicle ... Environmental Product

EPD VERIFICATION

This EPD was independently verified by ASTM in accordance with ISO 14025:

Internal External

X

Jamie Meil, Research Principal Athena Sustainable Materials Institute100-119 Ross AvenueOttawa, Ontario, Canada K1Y0N6

Signed:

Program Operator

Timothy Brooke ASTM International100 Bar Harbor DriveWest Conshohocken, PA [email protected]

Signed:

Declaration Holder Sika Corporation

Product group Date of Issue Period of Validity Declaration Number

03/01/2016 5 years EPD028

DECLARATION TYPEA “Cradle-to-Gate” EPD for four selected thicknesses of the Sarnafil G410 roofing membrane (48, 60, 72 and 80 mils). The modules included are A1 to A3. The declaration is intended for use in Business to Business (B-B) communication.

PRODUCT APPLICABILITY AND CHARACTERISTICS The declared Sarnafil G410 roofing membrane thicknesses (48, 60, 72 and 80 mils) are designed for low-slope and steep slope roofing applications. The membrane includes an internal fiberglass mat reinforcement to provide the dimensional stability required for adhered roof systems.

CONTENT OF THE DECLARATIONThis declaration follows Section 11, Content of the EPD, ASTM International Product Category Rules for Preparing an Environmental Product Declaration for Single-Ply Roofing Membranes, November 2013.

EPD PROJECT REPORT INFORMATION

EPD PROJECT REPORT A “Cradle-to-Gate” Life Cycle Assessment for four thicknesses of Sarnafil G410 (48, 60, 72 and 80 mils), 01/31/2016

LCA AND EPD PREPARED BY:

Corporate Poduct SustainabilitySika Services AGTüffenwies 168050 [email protected]

PCR INFORMATION

PROGRAM OPERATOR ASTM International

REFERENCE PCR ASTM International, Product Category Rules for Preparing an Environmental Product Declaration for Single Ply Roofing Membranes

DATE OF ISSUE November 2013

PCR REVIEW WAS CONDUCTED BY:Francois Charron-DoucetQuantis InternationalEmail : [email protected]

Page 7: ROOFING ENVIRONMENTAL PRODUCT DECLARATION · PDF file3 Insulation 4 Insulation Fastener ... of products and systems for the construction and motor vehicle ... Environmental Product

GLOBAL BUT LOCAL PARTNERSHIP

SIKA CORPORATION—ROOFING 100 Dan Road Canton, MA 02021 Tel: 800-451-2504 Fax: 781-828-5365 usa.sarnafil.sika.com [email protected]

Our most current General Sales Conditions shall apply. Please consult the Product Data Sheet prior to any use and processing.ISO 14001: 2004-Compliant

ENERGY STAR® for roofing products is only valid in the United States.ENERGY STAR® is a trademark of the U.S. EPA. LEED® is a trademark of the U.S. Green Building Council. Green Globes® is a trademark of the Green Building Initiative.

WHO WE ARESika AG, located in Baar, Switzerland, is a specialty chemicals company with a leading position in the development and production of systems and products for bonding, sealing, damping, reinforcing and protecting in the building sector and the motor vehicle industry.

The corporation has subsidiaries in 84 countries, employs 16,000 people worldwide, and has more than 160 manufacturing facilities around the globe.