Roof Replacement Project:
Huntley CSD#158
Roof Plan withProjections
Conley Elementary750 Academic DriveAlgonquin, Il. 60120
Roof I
Roof B
Roof D
Roof C
RoofH
RoofG
Roof O
Roof NRoof M
Roof L
Roof E
Roof F
Roof J
Roof P
RoofK
N
Shingle Roof AreasRoof E, F, G & H
Roof LRoof MRoof NRoof O
Total
517 Squares9 Squares5 Squares7 Squares
4 1/2 Squares
542 1/2 Squares
ASPHALT & GRAVEL SURFACED BURN.I.C.
STANDING SEAM METAL ROOFN.I.C.
COURT YARD
STANDING SEAM METAL ROOFN.I.C.
N.I.C.
N.I.C.
N.I.C.
264'
121' 66'77'
74'
55'
69'
125'
7'-6"
7'-6"
7'-6"
60'
7'-6"
95'
AD1
D1
D1
D1
D1
D1
AD1
AD1
D1
7'-6"
58'
256'
11'
D1
D1
74'
75' 90'
09-24-17
AD1
D1
General Notes:
A
C
D
F
C
E
Self-adhering Underlayment6' Width at Rake Edge
Self-adhering Underlayment3' Width, ech side of Ridge
Self-adhering Underlayment6' Width at Drip Edge/Gutter Edge
Self-adhering Underlayment6' Width at Side Walls.Run up Vertical 4" min.
Self-adhering Underlayment3' Width each side of Dormer Valley
Self-adhering Underlayment6' Width outside of Eyebrow Dormer Valley
Self-adhering UnderlaymentCompletely cover Eybrow Dormer
Self-adhering Underlayment3' Width below Dormer.Run up Vertical 4" min.
Self-adhering Underlayment3' Width, ech side of Ridge Self-adhering Underlayment
6' Width at Side WallsRun up Vertical 4" min.Self-adhering Underlayment
6' Width at Drip Edge/Gutter Edge
Self-adhering Underlayment6' Width at Rake Edge
Self-adhering Underlayment12' Width in Open Valleys
Self-adhering Underlayment12' Width in Open Valleys
Self-adhering UnderlaymentCompletely cover all Lower Shed Roofs
Note 2
Remove all pre-existing ridge ventsprior to installation of new specified vents
see Note #3
file: SD158181
roof areas approximateBidders shall field verify
Install new roof anchors at ridge 25' O.C.see Note #4
F
D
D1G
Note 1: All dimensions are for reference. Bidding contractors shall have sole responsibility for verifingand submitting bids based on the accuracy of their measurements.
Note 2: Enclose designated duct with exterior grade 3/4" plywood. Enclosure shall extend down to structural metal deck.Cover plywood enclosure with self-adhering granule surfaced modified bitumen membrane and base sheet. Flashat roof level and strip-in with 5 course mastic and mesh seal. Scarify flood coat down to top ply. 6" beyond toe of cant.
Note 3: Remove all pre-existing ridge vents prior to installation of new specified vents. Replace entire sheetwith treated 1"X dimensional lumber (no plywood) affected by vent opening (do not 'patch' individual vent openings).For specifications on shoebox vent replacements see BTC drawings and specifications.
Note 4: Install new permanant roof anchors 25' O.C. on all ridge lines. See detail Detail 'L', Sheet D-1.
Note 5: Refer to typical details where not called out.
rev3 on 10-24-17
rev1 on 10-10-17, rev2 on 10-18-17,
L
Project Notes:
Project Number:
Date:
Sheet Number:
Drawing Title:
Huntley CSD#158
Roof Plan withProjections
09-14-17
Heineman Middle School725 Academic DriveAlgonquin, Il. 60120
Roof A
Roof B
Roof C
Roof DRoof ERoofI
Roof H
Roof G
Roof F
Roof N
Roof M
Roof JRoofKRoof
L
Roof ORoof P
N
D2
D2
MATCH LINE
28'
53'
15'
94'-6"
94'-6"
28'
121'
150'
MATCH LINE
D2
81'-6"
78'
15'
53'
191'
D2
MATCH LINE
MATCH LINE
67'-6"
Roof Restoration Project:
A
D2C
D2E
D
D2A
D
D2
D2A
FA
D2C
D2A
D2A
POLYMER MODIFIED PRIMER @ 225 SQFT/GAL +/- 10%
POLYESTER REINFORCING SET INTO WET BASE COAT, DRYROLL LIGHLY TO EMBED
APPLY TOP COAT @ 2 GAL./SQUARE, BACKROLL TO ACHEIVE APPROX. 32 WET MILS
EXISTING STRUCTURAL METAL DECK
EXISTING MECHANICALLY ATTACHED POLYISOCYANURATE INSULATION LAYERS
EXISTING FULLY ADHERED 60 MIL. EPDM MEMBRANE TO REMAIN,POWERWASH & PREP. WITH POLYMER MODIFIED PRIMER AS SPECIFIED
BASE COAT OF POLYURETHANE @ 3 GAL./SQUARE, BACKROLL TO ACHEIVE APPROX. 48 MILS
Roof Construction Profile:Fully Adhered EPDM Single Ply Membrane on Structural Metal Deck
Polyurethane Rehabilitation
0 5 10 25 50 75 100 file: SD158187
Roof Areas:A, B & C
S C A L E I N F E E T
General Notes:
D2A
D2A
D2A
INCLUDE ALL LOWER ROOF AREAS
D2F
Fall Protection Warning Line
Fall ProtectionWarning Line
D2
327 Squares51 1/2 Squares
53 Squares
431 1/2 Squares
Roof ARoof BRoof C
Total
roof areas approximateBidders shall field verify
A
D2AD2
B
D2B
Contractors shall include all smalllower roof areas and verify sqftg.
Note 1: All dimensions are for reference. Bidding contractors shall have sole responsibility for verifyingand submitting bids based on the accuracy of their measurements.
Note 2: Remove all existing walkpads. Peel existing pad from EPDM membrane, or cut out walkwayand membrane and patch with new EPDM membrane. Either options cost shall be included in base bid.Replace existing walkways with textured surface in fluid-applied restoration system.
Note 3: Fluid applied membrane shall extend under all splash blocks, wood sleepers, lightning protectioncables, antenna 'sleds', etc.
Note 4: Refer to typical details where not called out.
rev1 10-10-17, rev2 on 10-18-17,
rev3 10-24-17
Project Notes:
Project Number:
Date:
Sheet Number:
Drawing Title:
Huntley CSD#158
Roof Plan withProjections
09-14-17
Roof Restoration Project:
Heineman Middle School725 Academic DriveAlgonquin, Il. 60120
Roof A
Roof B
Roof C
Roof DRoof ERoofI
Roof H
Roof G
Roof F
Roof N
Roof M
Roof JRoofKRoof
L
Roof O
N
file: SD158186
D2
D2
D2
D2
D2
D2
16'
67'-6"
134'-6" 105'-6"
17'-6"19'
18'
93'
74'
32'
D2
126'
D2
D2
D
F
B
D2C
A
B
POLYMER MODIFIED PRIMER @ 225 SQFT/GAL +/- 10%
POLYESTER REINFORCING SET INTO WET BASE COAT, DRYROLL LIGHLY TO EMBED
APPLY TOP COAT @ 2 GAL./SQUARE, BACKROLL TO ACHEIVE APPROX. 32 WET MILS
EXISTING STRUCTURAL METAL DECK
EXISTING MECHANICALLY ATTACHED POLYISOCYANURATE INSULATION LAYERS
EXISTING FULLY ADHERED 60 MIL. EPDM MEMBRANE TO REMAIN,POWERWASH & PREP. WITH POLYMER MODIFIED PRIMER AS SPECIFIED
BASE COAT OF POLYURETHANE @ 3 GAL./SQUARE, BACKROLL TO ACHEIVE APPROX. 48 MILS
0 5 10 25 50 75 100
S C A L E I N F E E T
A
A
A
B
General Notes:
Roof P
105'-6"
10'
Roof Construction Profile:Fully Adhered EPDM Single Ply Membrane on Structural Metal Deck
Polyurethane Rehabilitation
114'
Roof Areas:D, E, F, G, H and P
Roof DRoof ERoof FRoof GRoof HRoof P
Total
114 1/2 Squares136 1/2 Squares
11 squares5 1/2 squares4 1/2 squares
1 Square
273 Squares
Fall Protection Warning Line
Contractors shall include all smalllower roof areas and verify sqftg.
roof areas approximateBidders shall field verify
Note 1: All dimensions are for reference. Bidding contractors shall have sole responsibility for verifyingand submitting bids based on the accuracy of their measurements.
Note 2: Remove all existing walkpads. Peel existing pad from EPDM membrane, or cut out walkwayand membrane and patch with new EPDM membrane. Either options cost shall be included in base bid.Replace existing walkways with textured surface in fluid-applied restoration system.
Note 3: Fluid applied membrane shall extend under all splash blocks, wood sleepers, lightning protectioncables, antenna 'sleds', etc.
Note 4: Refer to typical details where not called out.
rev1 10-10-17, rev2 10-18-17,
rev3 10-24-17
Project Notes:
Project Number:
Date:
Sheet Number:
Drawing Title:
Huntley CSD#158
Roof Plan withProjections
09-14-17
Roof Restoration Project:
Heineman Middle School725 Academic DriveAlgonquin, Il. 60120
Roof A
Roof B
Roof C
Roof DRoof ERoofI
Roof H
Roof G
Roof F
Roof N
Roof M
Roof JRoofKRoof
L
Roof O
N
file: SD158185
0 5 10 25 50 75 100
S C A L E I N F E E T
POLYMER MODIFIED PRIMER @ 225 SQFT/GAL +/- 10%
POLYESTER REINFORCING SET INTO WET BASE COAT, DRYROLL LIGHLY TO EMBED
APPLY TOP COAT @ 2 GAL./SQUARE, BACKROLL TO ACHEIVE APPROX. 32 WET MILS
EXISTING STRUCTURAL METAL DECK
EXISTING MECHANICALLY ATTACHED POLYISOCYANURATE INSULATION LAYERS
EXISTING FULLY ADHERED 60 MIL. EPDM MEMBRANE TO REMAIN,POWERWASH & PREP. WITH POLYMER MODIFIED PRIMER AS SPECIFIED
BASE COAT OF POLYURETHANE @ 3 GAL./SQUARE, BACKROLL TO ACHEIVE APPROX. 48 MILS
Roof Construction Profile:Fully Adhered EPDM Single Ply Membrane on Structural Metal Deck
Polyurethane Rehabilitation
110'-6" 66'
114'-6"
54'59'-6"
45'
20'
24'39'
89'
53'
37'
D2
D2
D2
D2
18'
11' 47'
12'
D2F
Roof Areas:I, J, K, L, M, N and O
D2
D2
D2
D2B
A
B
D2A
D
B
A
C
C
D2A
RaisedPlatforms
D2E
D2C
D2B
General Notes:
Fall Protection Warning Line
Roof P
56 Squares76 1/2 Squares23 1/2 Squares36 1/2 Squares
5 Squares2 1/5 Squares
1/2 Square
200 1/2 Squares
Roof IRoof JRoof KRoof L
Roof MRoof NRoof 0
Total
roof areas approximateBidders shall field verify
Contractors shall include all smalllower roof areas and verify sqftg.
Note 1: All dimensions are for reference. Bidding contractors shall have sole responsibility for verifyingand submitting bids based on the accuracy of their measurements.
Note 2: Remove all existing walkpads. Peel existing pad from EPDM membrane, or cut out walkwayand membrane and patch with new EPDM membrane. Either options cost shall be included in base bid.Replace existing walkways with textured surface in fluid-applied restoration system.
Note 3: Fluid applied membrane shall extend under all splash blocks, wood sleepers, lightning protectioncables, antenna 'sleds', etc.
Note 4: Refer to typical details where not called out.
rev1 on 10-24-17
Project Notes:
Project Number:
Date:
Sheet Number:
Drawing Title:
Huntley CSD#158Roof Restoration Project:
Heineman Middle School725 Academic DriveAlgonquin, Il. 60120
Roof A
Roof B
Roof C
Roof DRoof ERoofI
Roof H
Roof G
Roof F
Roof N
Roof M
Roof JRoofKRoof
L
Roof O
N
Roof P
56 Squares76 1/2 Squares23 1/2 Squares36 1/2 Squares
5 Squares2 1/5 Squares
1/2 Square
200 1/2 Squares
Roof IRoof JRoof KRoof L
Roof MRoof NRoof 0
Total
roof areas approximateBidders shall field verify
Contractors shall include all smalllower roof areas and verify sqftg.
10-24-17
file: SD15818X
Roof Plan withWalkways
Project Notes:
Project Number:
Date:
Sheet Number:
Drawing Title:
Roof Replacement Project:
Huntley CSD#158
Roof Plan withProjections
Roof O
Roof MRoof N
Roof L
RoofG
RoofH
Roof CRoof E
Roof I
Roof D
Roof F
RoofK
Roof P
Roof J
Roof B
NN.I.C.
D1A
General Notes:
Shingle Roof AreasRoof E, F, G & H
Roof LRoof MRoof NRoof O
Total
517 Squares9 Squares5 Squares7 Squares
4 1/2 Squares
542 1/2 Squares
7'-6"
7'-6"
7'-6"
7'-6"
7'-6"
11' AD1
D1C
D1C
D1F
AD1
AD1
D1 D1
Self-adhering Underlayment6' Width at Side Walls.Run up Vertical 4" min.
Self-adhering Underlayment6' Width outside of Eyebrow Dormer Valley
Self-adhering UnderlaymentCompletely cover Eybrow Dormer
Self-adhering Underlayment6' Width at Rake Edge
Self-adhering Underlayment3' Width, ech side of Ridge
Self-adhering Underlayment6' Width at Drip Edge/Gutter Edge
Self-adhering Underlayment3' Width, ech side of Ridge
Self-adhering Underlayment6' Width at Rake Edge
Self-adhering UnderlaymentCompletely cover all Lower Shed Roofs
Self-adhering Underlayment3' Width below Dormer.Run up Vertical 4" min.
Self-adhering Underlayment12' Width in Open Valleys
Self-adhering Underlayment6' Width at Side WallsRun up Vertical 4" min.
Self-adhering Underlayment6' Width at Drip Edge/Gutter Edge
D1D
Remove all pre-existing ridge ventsprior to installation of new specified vents
see Note #1
D1E
COURT YARD
256'
125' 58'
74'
75'
74'
60'
77' 121' 66'
264'
AD1
90'
Self-adhering Underlayment12' Width in Open Valleys
09-28-17
85'
85'
66'
ASPHALT & GRAVEL SURFACED BURN.I.C.
N.I.C.
STANDING SEAM METAL ROOFN.I.C.
ASPHALT & GRAVEL SURFACED BURN.I.C.
STANDING SEAM METAL ROOFN.I.C.
N.I.C.
Mackeben Elementary800 Academic DriveAlgonquin, Il. 60120
SHINGLE ROOF AREA ONLY
file: SD158183
Install new roof anchors at ridge 25' O.C.see Note #3
D1I
D1D
G F
95'
69'
55'
roof areas approximateBidders shall field verify
Note 1: All dimensions are for reference. Bidding contractors shall have sole responsibility for verifingand submitting bids based on the accuracy of their measurements.
Note 2: Remove all pre-existing ridge vents prior to installation of new specified vents. Replace entire sheetwith treated 1"X dimensional lumber (no plywood) affected by vent opening (do not 'patch' individual vent openings).For specifications on shoebox vent replacements see BTC drawings and specifications.
Note 3: Install new permanant roof anchors 25' O.C. on all ridge lines. See detail Detail 'L', Sheet D-1.
Note 4: Refer to typical details where not called out.
rev1 on 10-10-17, rev2 on 10-18-17,
rev3 on 10-24-17
Project Notes:
Project Number:
Date:
Sheet Number:
Drawing Title:
N
Roof Replacement Project:
Huntley CSD#158
Marlowe Middle School9625 Haligus RoadLake in the Hills 60156
Roof Plan withProjections
09-14-17
Roof Q
Roof H
Roof I
Roof K RoofL
Roof JRoof T
Roof MRoof
NRoof
O
Roof D
Roof S
Roof A
Roof B
Roof CRoof E
Roof F
Roof G
Roof P
Roof R
191'
121'
150'
25'
28'
53'
15'
94'-6"
94'-6"
28'
53'
15'
25'
44'-6"
78'
81'-6"
Roof ARoof BRoof D
Total
327 Squares74 1/2 Squares
53 Squares
454 1/2 Squares
D2
D2
D2
D2
D2
MATCH LINE
MATCH LINE
MATCH LINE
MATCH LINE
Roof Areas:A, B & D
0 5 10 25 50 75 100
S C A L E I N F E E T
POLYMER MODIFIED PRIMER @ 225 SQFT/GAL +/- 10%
POLYESTER REINFORCING SET INTO WET BASE COAT, DRYROLL LIGHLY TO EMBED
APPLY TOP COAT @ 2 GAL./SQUARE, BACKROLL TO ACHEIVE APPROX. 32 WET MILS
EXISTING STRUCTURAL METAL DECK
EXISTING MECHANICALLY ATTACHED POLYISOCYANURATE INSULATION LAYERS
EXISTING FULLY ADHERED 60 MIL. EPDM MEMBRANE TO REMAIN,POWERWASH & PREP. WITH POLYMER MODIFIED PRIMER AS SPECIFIED
BASE COAT OF POLYURETHANE @ 3 GAL./SQUARE, BACKROLL TO ACHEIVE APPROX. 48 MILS
Roof Construction Profile:Fully Adhered EPDM Single Ply Membrane on Structural Metal Deck
Polyurethane Rehabilitation
A
A
F
D2F
D2
D
D
A
D2E
D2C
D2C
file: SD15818T
General Notes:
D2A
D2A INCLUDE ALL LOWER ROOFS
D2A
Fall Protection Warning Line
Contractors shall include all smalllower roof areas and verify sqftg.
roof areas approximateBidders shall field verify
rev1 on 10-18-17, rev2 on 10-24-17
Note 1: All dimensions are for reference. Bidding contractors shall have sole responsibilityfor verifying and submitting bids based on the accuracy of their measurements.
Note 2: Remove all existing walkpads. Peel existing pad from EPDM membrane, or cut outwalkway and membrane and patch with new EPDM membrane. Either options costshall be included in base bid. Replace existing walkways with textured surface influid-applied restoration system.
Note 3: Fluid applied membrane shall extend under all splash blocks, wood sleepers,lightning protection cables, antenna 'sleds', etc.
Note 4: Refer to typical details where not called out.
Project Notes:
Project Number:
Date:
Sheet Number:
Drawing Title:
N
Huntley CSD#158
Marlowe Middle School9625 Haligus RoadLake in the Hills 60156
Roof Plan withProjections
09-14-17
Roof Q
Roof H
Roof I
Roof K RoofL
Roof JRoof T
Roof MRoof
NRoof
O
Roof D
Roof S
Roof A
Roof B
Roof CRoof E
Roof F
Roof G
Roof P
Roof R
122'147'
133'
125'-6"
68'
262 SquaresRoof C
D2
D2
D2
D2
D2
Roof Restoration Project:
Roof Area: C
POLYMER MODIFIED PRIMER @ 225 SQFT/GAL +/- 10%
POLYESTER REINFORCING SET INTO WET BASE COAT, DRYROLL LIGHLY TO EMBED
APPLY TOP COAT @ 2 GAL./SQUARE, BACKROLL TO ACHEIVE APPROX. 32 WET MILS
EXISTING STRUCTURAL METAL DECK
EXISTING MECHANICALLY ATTACHED POLYISOCYANURATE INSULATION LAYERS
EXISTING FULLY ADHERED 60 MIL. EPDM MEMBRANE TO REMAIN,POWERWASH & PREP. WITH POLYMER MODIFIED PRIMER AS SPECIFIED
BASE COAT OF POLYURETHANE @ 3 GAL./SQUARE, BACKROLL TO ACHEIVE APPROX. 48 MILS
Roof Construction Profile:Fully Adhered EPDM Single Ply Membrane on Structural Metal Deck
Polyurethane Rehabilitation
file: SD15818E
0 5 10 25 50 75 100
S C A L E I N F E E T
A
D2C
A
AD
A
D2C
D2E
D2D
General Notes:
D2A
D2A
INCLUDE ALL LOWER ROOF AREAS
Fall Protection Warning Line
roof areas approximateBidders shall field verify
Contractors shall include all smalllower roof areas and verify sqftg.
Note 1: All dimensions are for reference. Bidding contractors shall have sole responsibility for verifyingand submitting bids based on the accuracy of their measurements.
Note 2: Remove all existing walkpads. Peel existing pad from EPDM membrane, or cut out walkwayand membrane and patch with new EPDM membrane. Either options cost shall be included in base bid.Replace existing walkways with textured surface in fluid-applied restoration system.
Note 3: Fluid applied membrane shall extend under all splash blocks, wood sleepers, lightning protectioncables, antenna 'sleds', etc.
Note 4: Refer to typical details where not called out.
rev1 on 10-18-17, rev2 on 10-24-17
Project Notes:
Project Number:
Date:
Sheet Number:
Drawing Title:
N
Huntley CSD#158
Marlowe Middle School9625 Haligus RoadLake in the Hills 60156
Roof Plan withProjections
09-14-17
Roof Q
Roof H
Roof I
Roof K RoofL
Roof JRoof T
Roof MRoof
NRoof
O
Roof D
Roof S
Roof A
Roof B
Roof CRoof E
Roof F
Roof G
Roof P
Roof R
134'-6"105'-6"
93'
74'
105'-6" 36'
54'
126'
32'
67'-6"19'17'-6"
32'16'
18'
10'
Roof ERoof FRoof GRoof HRoof I
Roof JRoof KRoof QRoof T
Total
11 Squares5 1/2 squares4 1/2 squares
114 1/2 squares79 Squares*23 Squares
133 Squares6 Squares1/2 Square
376 Squares
Roof Restoration Project:
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
Roof Areas:E, F, G, H, I, J, K, Q and T
POLYMER MODIFIED PRIMER @ 225 SQFT/GAL +/- 10%
APPLY TOP COAT @ 2 GAL./SQUARE, BACKROLL TO ACHEIVE APPROX. 32 WET MILS
EXISTING STRUCTURAL METAL DECK
EXISTING MECHANICALLY ATTACHED POLYISOCYANURATE INSULATION LAYERS
Roof Construction Profile:Fully Adhered EPDM Single Ply Membrane on Structural Metal Deck
Polyurethane Rehabilitation
POLYESTER REINFORCING SET INTO WET BASE COAT, DRYROLL LIGHLY TO EMBED
BASE COAT OF POLYURETHANE @ 3 GAL./SQUARE, BACKROLL TO ACHEIVE APPROX. 48 MILS
EXISTING FULLY ADHERED 60 MIL. EPDM MEMBRANE TO REMAIN,POWERWASH & PREP. WITH POLYMER MODIFIED PRIMER AS SPECIFIED
B
D2C
B
D2
D2
D
F
B
A
A
A
B
A
A
B
file: SD158188
D2B
D2A
D2A
D2A
General Notes:
0 5 10 25 50 75 100
S C A L E I N F E E T
Fall Protection Warning Line
rev1 on 10-18-17, rev2 on 10-24-17
Note 1: All dimensions are for reference. Bidding contractors shall have sole responsibility for verifyingand submitting bids based on the accuracy of their measurements.
Note 2: Remove all existing walkpads. Peel existing pad from EPDM membrane, or cut out walkwayand membrane and patch with new EPDM membrane. Either options cost shall be included in base bid.Replace existing walkways with textured surface in fluid-applied restoration system.
Note 3: Fluid applied membrane shall extend under all splash blocks, wood sleepers, lightning protectioncables, antenna 'sleds', etc.
Note 4: Refer to typical details where not called out.
Project Notes:
Project Number:
Date:
Sheet Number:
Drawing Title:
N
Huntley CSD#158
Marlowe Middle School9625 Haligus RoadLake in the Hills 60156
Roof Plan withProjections
09-14-17
Roof Q
Roof H
Roof I
Roof K RoofL
Roof JRoof T
Roof MRoof
NRoof
O
Roof D
Roof S
Roof A
Roof B
Roof CRoof E
Roof F
Roof G
Roof P
Roof R
56 Squares76 1/2 Squares23 1/2 Squares36 1/2 Squares
5 Squares2 1/5 Squares
1/2 Square
200 1/2 Squares
Roof Restoration Project:
POLYMER MODIFIED PRIMER @ 225 SQFT/GAL +/- 10%
POLYESTER REINFORCING SET INTO WET BASE COAT, DRYROLL LIGHLY TO EMBED
APPLY TOP COAT @ 2 GAL./SQUARE, BACKROLL TO ACHEIVE APPROX. 32 WET MILS
EXISTING STRUCTURAL METAL DECK
EXISTING MECHANICALLY ATTACHED POLYISOCYANURATE INSULATION LAYERS
EXISTING FULLY ADHERED 60 MIL. EPDM MEMBRANE TO REMAIN,POWERWASH & PREP. WITH POLYMER MODIFIED PRIMER AS SPECIFIED
BASE COAT OF POLYURETHANE @ 3 GAL./SQUARE, BACKROLL TO ACHEIVE APPROX. 48 MILS
Roof Construction Profile:Fully Adhered EPDM Single Ply Membrane on Structural Metal Deck
Polyurethane Rehabilitation
47' 54' 59'-6" 20' 11'
39'24'
53'
89'
37'
110'-6"66'
114'-6"
D2
D2
D2
D2
12'
18'
D245'
D2
D2
D2
D2
D2
D2
D2
D
F
A
C
A
A
A
C
E
B
B
A
Roof Areas:L, M, N, O, P, R and S
Roof LRoof MRoof NRoof ORoof PRoof RRoof S
Total
D2F
General Notes:
0 5 10 25 50 75 100
S C A L E I N F E E T
Fall Protection Warning Line
Note 1: All dimensions are for reference. Bidding contractors shall have sole responsibility for verifyingand submitting bids based on the accuracy of their measurements.
Note 2: Remove all existing walkpads. Peel existing pad from EPDM membrane, or cut out walkwayand membrane and patch with new EPDM membrane. Either options cost shall be included in base bid.Replace existing walkways with textured surface in fluid-applied restoration system.
Note 3: Fluid applied membrane shall extend under all splash blocks, wood sleepers, lightning protectioncables, antenna 'sleds', etc.
Note 4: Refer to typical details where not called out.
file: SD158189
rev1 on 10-24-17
Project Notes:
Project Number:
Date:
Sheet Number:
Drawing Title:
N
Huntley CSD#158
Marlowe Middle School9625 Haligus RoadLake in the Hills 60156
Roof Q
Roof H
Roof I
Roof K RoofL
Roof JRoof T
Roof MRoof
NRoof
O
Roof D
Roof S
Roof A
Roof B
Roof CRoof E
Roof F
Roof G
Roof P
Roof R
56 Squares76 1/2 Squares23 1/2 Squares36 1/2 Squares
5 Squares2 1/5 Squares
1/2 Square
200 1/2 Squares
Roof Restoration Project:
Roof LRoof MRoof NRoof ORoof PRoof RRoof S
Total
Roof Plan withWalkways
file: SD15818W
10-24-17
Project Notes:
Project Number:
Date:
Sheet Number:
Drawing Title:
Roof Replacement Project:
Flashing Details
SHEET METAL VALLEY FALSHING6" MIN. END LAPS, BLIND-NAIL
TOP EDGE AS SPECIFIED
HIGH STRENGTH TRILAMINATE BASE SHEET
LAMINATED SHINGLES AS SPECIFIED
SET SHEET METAL VALLEYFLASHING WITH METALCLIPS AS SPECIFIED
INSPECT OSB/NAILBASE SUBSTRATE REPLACINGDAMAGED AS NECESSARY BASED ON UNIT PRICE
NEW LAMINATED SHINGLE AS SPECIFIED
HIGH STREGTH TRILAMINATE BASE SHEET
SELF-ADHERED ICE AND WATER UNDERLAYMENT
Open Metal ValleyDrip EdgeGutter EdgeA B D
HIGH STRENGTH TRILAMINATE BASE SHEET
LAMINATED SHINGLES AS SPECIFIED
EXTRA FASTENERAT SHINGLE END
CUT SHINGLES OFUPPER COURSE ANDTRIM CORNERS. NOFASTENERS WITHIN6" OF VALLEYCENTERLINE
EXTEND EACH END SHINGLE 12"MIN. BEYOND VALLEY CENTERLINE
CONTINUOUS SEALANT
9' WIDTH SELF-ADHERING UNDERLAYMENT
Closed-Cut Valley DetailE
SELF-ADHERING UNDERLAYMENT(SEE UNDERLAYMEN LAYOUT DRAWING
FOR SPECIFIC WIDTH REQUIREMENTS)
24' WIDE SHEET METAL VALLY FLASHING
09-25-17
NEW LAMINATED SHINGLE AS SPECIFIED
HIGH STREGTH TRILAMINATE BASE SHEET
SELF-ADHERED ICE AND WATER UNDERLAYMENT
INSPECT OSB/NAILBASE SUBSTRATE REPLACINGDAMAGED AS NECESSARY BASED ON UNIT PRICE
REUSE DRIP EDGE SHEET METALINSPECT AND REFASTEN AS NECESSARY REUSE DRIP EDGE SHEET METAL
INSPECT AND REFASTEN AS NECESSARY
REUSE EXISTING GUTTERINSPECT STRAPS REPLACE
AND FASTEN AS NECESSARY
NEW LAMINATED SHINGLE AS SPECIFIED
EXISTING THRU-WALL FLASHING 'STEPPED' INTO MASONRY
NEW SURFACE MOUNT COUNTERFLASHINGFASTENED AND SEALED AS SPECIFIED
INSPECT OSB/NAILBASE SUBSTRATE REPLACINGDAMAGED AS NECESSARY BASED ON UNIT PRICE
REPLACE SHEET METAL APRON FLASHINGOVER NEW SELF ADHERED UNDERLAYMENT
Surface-mount Counterflashing under 'Steeped' Thru-wall
HIGH STREGTH TRILAMINATE BASE SHEET
SELF-ADHERED ICE AND WATER UNDERLAYMENT
NEW LAMINATED SHINGLE AS SPECIFIED
INSPECT OSB/NAILBASE SUBSTRATE REPLACINGDAMAGED AS NECESSARY BASED ON UNIT PRICE
Wall Flashing Detail
SHEET METAL STUCCO-STOP/APRON FLASHING WITH HEMMED DRIP EDGE
NEW LAMINATED SHINGLE AS SPECIFIED
FASCIA TO REMAIN
HIGH STREGTH TRILAMINATE BASE SHEET(extend 3" over edge of self-adhering membrane)
SELF-ADHERED ICE & WATER UNDERLAYMENT(extend 36" beyond inside face of exterior wall)
Rake Edage Detail
RIDGE CAP SHINGLE
REUSE EXISTING DRIP EDGE SHEET METAL
NEW LAMINATED SHINGLE AS SPECIFIED
HIGH STREGTH TRILAMINATE BASE SHEET
SELF-ADHERED ICE AND WATER UNDERLAYMENT
INSPECT OSB/NAILBASE SUBSTRATE REPLACINGDAMAGED AS NECESSARY BASED ON UNIT PRICE
Conley Elementary750 Academic DriveAlgonquin, Il. 60120
Mackeben Elementary800 Academic DriveAlgonquin, Il. 60120
Consolidated SchoolDistrict #158
and
C
F G H
NEW LAMINATED SHINGLE AS SPECIFIED
SHEET METAL STACK APRON
INSPECT OSB/NAILBASE SUBSTRATE REPLACINGDAMAGED AS NECESSARY BASED ON UNIT PRICE
SHEET METAL STACK FLASHINGSEAL AND FASTEN AS SPECIFIED
SHEET METAL STACK FLASHINGSEAL AND FASTEN AS SPECIFIED
NEW LAMINATED SHINGLE AS SPECIFIED
INSPECT OSB/NAILBASE SUBSTRATE REPLACINGDAMAGED AS NECESSARY BASED ON UNIT PRICE
REUSE EXISTING SHEET METALCRICKET OVER PLYWOODINSTALL 3' WIDE SELF-ADHERINGUNDERLAYMENT
EXISTING SHEET METAL CURB APRON
NEW LAMINATED SHINGLE AS SPECIFIED
INSPECT OSB/NAILBASE SUBSTRATE REPLACINGDAMAGED AS NECESSARY BASED ON UNIT PRICE
LEAD FLASHING SHEET AS SPECIFIED
ROLL LEAD FLASHING INTO PLUMBING VENT 1" MIN.
6" MIN. FLANGE
'Hot' Stack Steep-slope Detail Curb Flashing Steep-slope DetailI
Soil Stack/Plumbing Vent Steep-slope Detail
Shed Wall Detail
EFIS/MASONRY/SIDING WALL
file: SD15818A
General Note:Reuse of sheet metal flashingcomponents reference only appliesto components that are notdamaged during construction process.
J K
NON-VENTED RIDGE CAP SHINGLE
PERMANENT ROOF ANCHOR AS SPECIFIED
Ridge and Permanent Roof AnchorL
rev1 10-10-17, rev2 10-13-17,
rev3 10-18-17
ENCLOSE EXISTING VENT OPENING, with 1"X DIMENSIONAL LUMBER (NO PLYWOOD)
Project Notes:
Project Number:
Date:
Sheet Number:
Drawing Title:
ROOFFLASHING DETAILS
Consolidated School District #158
Roof Restoration Project:
Heinemaan Middle School725 Academic DriveAlgonquin, Il. 60120
Marlowe Middle School9625 Haligus RoadLake in the Hills, Il. 60156
10-03-17
STRUCTURAL METAL DECK
Reglet Mounted Counter Flashing Detail
STRUCTURAL METAL DECK
Membrane Covered Wall Flashing DetailA B C
STRUCTURAL METAL DECKSTRUCTURAL METAL DECK
D
EXISTING SHEET METAL COUNTERFLASHING AND RECEIVER TO REMAIN.
EXISTING MECHANICALLY ATTACHED INSULATION LAYERS
INSPECT AND REPAIR EXISTING EPDM FLASHING MEMBRANE PRIOR TOAPPLICATION OF FLUID APPIED COATING AND REINFORCING FABRIC.
CONTINUOUS APPLICATION OF POLYURETHANE AND POLYESTER FLUID APPLIEDMEMBRANE OVER EXISTING EPDM FLASHING MEMBRANE. CLEAN AND PRIME EPDMSURFACE AS SPECIFIED.
CONTINUOUS APPLICATION OF POLYURETHANE AND POLYESTERFLUID APPLIED MEMBRANE OVER EXISTING EPDM FIELD MEMBRANE.CLEAN AND PRIME EPDM SURFACE AS SPECIFIED.
INSPECT OLD SEALANT IN EXISTING REGLET. REPAIR ANY REVEALED DETERIORATION.DO NOT IMPEDE WEEPS. PROTECT EXISTING METAL SKIRT FROM FLUID APPLIEDAPPLICATION 'OVERAGE'. RECOMMEND APPLYING PAINTERS MASKING TAPE.CONTRACTOR WILL BE RESPONSIBLE FOR CLEANING EXCESS OFF METAL AND WALLS.
EXISTING MECHANICALLY ATTACHED INSULATION LAYERS
EXISTING EPDM MEMBRANE TO REMAIN. CLEAN AND PRIME EPDM SURFACEAS SPECIFIED. CONTINUOUS APPLICATION OF POLYURETHANE AND POLYESTERFLUID APPLIED MEMBRANE OVER EXISTING EPDM WALL MEMBRANE.
CONTINUOUS APPLICATION OF POLYURETHANE AND POLYESTERFLUID APPLIED MEMBRANE OVER EXISTING EPDM FIELD MEMBRANE.CLEAN AND PRIME EPDM SURFACE AS SPECIFIED.
CONTINUOUS APPLICATION OF POLYURETHANE AND POLYESTER FLUID APPLIEDMEMBRANE OVER EXISTING EPDM FLASHING MEMBRANE. CLEAN AND PRIME EPDMSURFACE AS SPECIFIED.
EXISTING MECHANICALLY ATTACHED INSULATION LAYERS
INSPECT AND REPAIR EXISTING EPDM FLASHING MEMBRANE PRIOR TOAPPLICATION OF FLUID APPIED COATING AND REINFORCING FABRIC.
EXISTING SHEET METAL REGLET MOUNT COUNTERFLASHING TO REMAIN
INSPECT AND REPAIR EXISTING EPDM FLASHING MEMBRANE PRIOR TOAPPLICATION OF FLUID APPIED COATING AND REINFORCING FABRIC.
INSPECT AND REPAIR EXISTING EPDM WALL MEMBRANE PRIOR TOAPPLICATION OF FLUID APPIED COATING AND REINFORCING FABRIC.
EXISTING 'SLIP' SHEET METAL SURFACE MOUNT COUNTERFLASHING TO REMAIN.PROTECT EXISTING METAL SKIRT FROM FLUID APPLIED APPLICATION 'OVERAGE'.RECOMMEND APPLYING PAINTERS MASKING TAPE. CONTRACTOR WILL BE RESPONSIBLEFOR CLEANING EXCESS OFF METAL AND WALLS.
INSPECT EXISTING SHEET METAL COPING CAP. ALERT OWNER TO ANYSUSPECT SEALANT OR FASTENING ISSUES THAT MAY NEED TO BE ADDRESSED.
INSPECT OLD SEALANT IN EXISTING REGLET. REPAIR ANY REVEALED DETERIORATION.DO NOT IMPEDE WEEPS. PROTECT EXISTING METAL SKIRT FROM FLUID APPLIEDAPPLICATION 'OVERAGE'. RECOMMEND APPLYING PAINTERS MASKING TAPE.CONTRACTOR WILL BE RESPONSIBLE FOR CLEANING EXCESS OFF METAL AND WALLS.
CONTINUOUS APPLICATION OF POLYURETHANE AND POLYESTER FLUID APPLIEDMEMBRANE OVER EXISTING EPDM FLASHING MEMBRANE. CLEAN AND PRIME EPDMSURFACE AS SPECIFIED.
CONTINUOUS APPLICATION OF POLYURETHANE AND POLYESTER FLUID APPLIEDMEMBRANE OVER EXISTING EPDM FLASHING MEMBRANE. CLEAN AND PRIME EPDMSURFACE AS SPECIFIED.
INSPECT AND REPAIR EXISTING EPDM FLASHING MEMBRANE PRIOR TOAPPLICATION OF FLUID APPIED COATING AND REINFORCING FABRIC.
CONTINUOUS APPLICATION OF POLYURETHANE AND POLYESTERFLUID APPLIED MEMBRANE OVER EXISTING EPDM FIELD MEMBRANE.CLEAN AND PRIME EPDM SURFACE AS SPECIFIED.
CONTINUOUS APPLICATION OF POLYURETHANE AND POLYESTERFLUID APPLIED MEMBRANE OVER EXISTING EPDM FIELD MEMBRANE.CLEAN AND PRIME EPDM SURFACE AS SPECIFIED.
EXISTING MECHANICALLY ATTACHED INSULATION LAYERS
Eifs Wall Reglet Mounted Counter Flashing Detail
EIFS COVERED WALL
Parapet with Metal Coping Cap Detail
STRUCTURAL METAL DECK
REPLACE ALL PLASTIC AND ANY BROKEN METALDOMES WITH METAL DRAIN STRAINER BASKETS
STRUCTURAL METAL DECK
FIN. ROOF
INSPEC EXISTING CLAMPING RING. TIGHTEN ALL LOOSE BOLTS.APPLY FLUID APPIED MEMBRANE SYSTEM UP TO CLAMPING RING.
INSPECT AND REPAIR EXISTING EPDM MEMBRANE PRIOR TOAPPLICATION OF FLUID APPIED COATING AND REINFORCING FABRIC.
CONTINUOUS APPLICATION OF POLYURETHANE AND POLYESTERFLUID APPLIED MEMBRANE OVER EXISTING EPDM FIELD MEMBRANE.
CLEAN AND PRIME EPDM SURFACE AS SPECIFIED.
EXISTING TAPERED INSULATION SUMP
EXISTING MECHANICALLY ATTACHED INSULATION LAYERS
CONTINUOUS APPLICATION OF POLYURETHANE AND POLYESTERFLUID APPLIED MEMBRANE OVER EXISTING EPDM FIELD MEMBRANE.
CLEAN AND PRIME EPDM SURFACE AS SPECIFIED.
EXISTING MECHANICALLY ATTACHED INSULATION LAYERS
CONTINUOUS APPLICATION OF POLYURETHANE AND POLYESTER FLUID APPLIEDMEMBRANE OVER EXISTING EPDM FLASHING MEMBRANE.
CLEAN AND PRIME EPDM SURFACE AS SPECIFIED.
EXISTING PRE-FAB SHEET METAL or WOOD CURB
EXISTING EXHAUST VENT/EQUIPMENT SHEET METAL TO REMAIN.PROTECT EXISTING METAL SKIRT FROM FLUID APPLIED APPLICATION 'OVERAGE'.
RECOMMEND APPLYING PAINTERS MASKING TAPE. CONTRACTOR WILL BE RESPONSIBLEFOR CLEANING EXCESS OFF METAL.
Equipment Curb DetailRoof Drain DetailE F
STRUCTURAL METAL DECK
EXISTING MECHANICALLY ATTACHEDINSULATION LAYERS
Non-Penetrating Equipment Support/Pad Detail
EXISTING PIPE SUPPORT TO REMAIN. PROVIDE TEMPORARYSUPPORT, LIFT EXISTING PADS. CONTINUOUS APPLICATION OFFLUID APPLIED SYSTEM SHALL BE INSTALLED UNDER ALL PADSAND WOOD BLOCKING WHERE LIGHTER WEIGHT EQUIPMENTHAS BEEN INSTALLED NOT PENETRATING THE EPDM MEMBRANE.PROTECT EXISTING METAL CAP FROM FLUID APPLIED APPLICATION'OVERAGE'. RECOMMEND WRAPPING PIPING. CONTRACTOR WILLBE RESPONSIBLE FOR CLEANING EXCESS OFF METAL.
FIN. ROOF
'Hot' Stack Low-slope Detail
CONTINUOUS APPLICATION OF POLYURETHANE AND POLYESTERFLUID APPLIED MEMBRANE OVER EXISTING EPDM FIELD MEMBRANE.CLEAN AND PRIME EPDM SURFACE AS SPECIFIED.
CONTINUOUS APPLICATION OF POLYURETHANE AND POLYESTERFLUID APPLIED MEMBRANE OVER EXISTING EPDM FIELDMEMBRANE. CLEAN AND PRIME EPDM SURFACE AS SPECIFIED.EXTEND FLUID APPLIED SYSTEM UP SHEET METAL PITCH POCKETPRIME METAL WITH 'M' PRIME
STRUCTURAL METAL DECK
EXISTING MECHANICALLY ATTACHED INSULATION LAYERS
INSPECT DRAWBAND CLAMP. TIGHTEN AND RESEAL AS NECESSARY
CONTINUOUS APPLICATION OF POLYURETHANEAND POLYESTER FLUID APPLIED MEMBRANE
OVER EXISTING EPDM FIELD MEMBRANE.CLEAN AND PRIME EPDM SURFACE AS SPECIFIED.
CONTINUOUS APPLICATION OF POLYURETHANE AND POLYESTERFLUID APPLIED MEMBRANE OVER EXISTING EPDM FIELDMEMBRANE. CLEAN AND PRIME EPDM SURFACE AS SPECIFIED.EXTEND FLUID APPLIED SYSTEM UP SHEET METAL VENT 4" MIN.PRIME METAL WITH 'M' PRIME
4" MIN.
WHERE EPDM WRAP TERMINATES ON VENT, EXTENDFLUID APPLIED FLASHING UP ONTO SHEET METAL4" MIN. PRIME METAL WITH 'M' PRIME
CONTINUOUS APPLICATION OF POLYURETHANE AND POLYESTERFLUID APPLIED MEMBRANE OVER EXISTING EPDM MEMBRANE,
INCLUDING UNDER PADS AND WOOD BLOCKING.CLEAN AND PRIME EPDM SURFACE AS SPECIFIED.
STRUCTURAL METAL DECK
Vent Stack Detail
EXISTING MECHANICALLY ATTACHED INSULATION LAYERS
STRUCTURAL METAL DECK
FLUID APPLIED POYURETHANE AND POLYESTERREIFORING MEMBRANE. RUN UP SOIL STACK 4' ABOVEEXISTING EPDM TERMINATION.
CLEAN PVC SOIL STACKS AND PRIMEWITH 'WB' PRIMER PRIOR TOAPPLICATION OF FLUID APPLIEDMEMBRANE AND REINFORCING.
CLEAN CAST IRON SOIL STACKS TO BARE METAL.PRIME WITH 'M' PRIME PRIOR TO APPLICATION OFFLUID APPLIED MEMBRANE AND REINFORCING.
'WRAPPED' FLASHING STACKPREFAB 'BOOT' FLASHING STACK
EXISTING MECHANICALLY ATTACHEDINSULATION LAYERS
CONTINUOUS APPLICATION OF POLYURETHANE AND POLYESTERFLUID APPLIED MEMBRANE OVER EXISTING EPDM FLASHING.
CLEAN AND PRIME EPDM SURFACE AS SPECIFIED.
CONTINUOUS APPLICATION OF POLYURETHANE AND POLYESTERFLUID APPLIED MEMBRANE OVER EXISTING EPDM FIELD MEMBRANE.
CLEAN AND PRIME EPDM SURFACE AS SPECIFIED.
EXISTING EQUIPMENT RAIL SHEET METAL CAP TO REMAIN.PROTECT EXISTING METAL CAP FROM FLUID APPLIED APPLICATION'OVERAGE'. RECOMMEND APPLYING PAINTERS MASKING TAPE.CONTRACTOR WILL BE RESPONSIBLE FOR CLEANING EXCESS OFF METAL.
Equipment Support/Rail Detail
CLEAN AND PRIME EXISTING EPDM PORTAL BOOTS WITH 'WB'APPLY BASE AND TOP COAT APPLICATIONS.
TERMINATE REINFORCING FABRIC AT BASE OF BOOT.
INSPECT BOOT CLAMP. TIGHTEN AND RESEAL AS NECESSARY
STRUCTURAL METAL DECK
EXISTING MECHANICALLY ATTACHED INSULATION LAYERS
CONTINUOUS APPLICATION OF POLYURETHANE AND POLYESTERFLUID APPLIED MEMBRANE OVER EXISTING EPDM FIELD AND FLASHINGMEMBRANE. CLEAN AND PRIME EPDM SURFACE AS SPECIFIED.
Hatch/Skylight/VentFlashing Detail Pitch Pocket Detail
SPECIFIED SEALANT AND BUTYL TAPE
STAINLESS STEEL DRAWBAND
EXISTING MECHANICALLYATTACHED INSULATION LAYERS
STRUCTURAL METAL DECK
SHEET METAL HOOD REQUIRED
STRUCTURAL METAL DECK
EXISTING MECHANICALLY ATTACHEDINSULATION LAYERS
EXISTING PIPE SUPPORT TO REMAIN. PROVIDE TEMPORARYSUPPORT, LIFT EXISTING PADS. CONTINUOUS APPLICATION OFFLUID APPLIED SYSTEM SHALL BE INSTALLED UNDER ALL PADSAND WOOD BLOCKING WHERE LIGHTER WEIGHT EQUIPMENTHAS BEEN INSTALLED NOT PENETRATING THE EPDM MEMBRANE.PROTECT EXISTING METAL CAP FROM FLUID APPLIED APPLICATION'OVERAGE'. RECOMMEND WRAPPING PIPING. CONTRACTOR WILLBE RESPONSIBLE FOR CLEANING EXCESS OFF METAL.
FIN. ROOF
G H
I J K L
M N O Conduits/Lightening Protection Boot Detail
CONTINUOUS APPLICATION OF POLYURETHANEAND POLYESTER FLUID APPLIED MEMBRANE OVER
EXISTING EPDM MEMBRANE. EXTENDFLUID APPLIED SYSTEM UP ONTO PROJECTION BOOT.
CLEAN AND PRIME EPDM SURFACE AS SPECIFIED.
Metal Edge Detail Raised Edge Detail
CONTINUOUSCLEAT
EXISTING MECHANICALLY ATTACHED INSULATION LAYERS
STRUCTURAL METAL DECK
PROTECT FASCIA SURFACE FROM FLUID-APPLIED APPLICATION 'OVERAGE'.CONTRACTOR WILL BE RESPONSIBLE FOR CLEANING EXCESS OFF METAL AND WALLS.
CONTINUOUS APPLICATION OF POLYURETHANE AND POLYESTERFLUID APPLIED MEMBRANE OVER EXISTING EPDM FIELD MEMBRANE.PRIME ANY EXISTING METAL LIGHTNING ROD BASES WITH 'M' PRIME.CLEAN AND PRIME EPDM SURFACE AS SPECIFIED.
APPLYING PAINTERS MASKING TAPE TO PREVENT FLUID APPLIED SYSTEM FROM ADHERING TO EDGE METAL
CONTINUOUSCLEAT
PROTECT FASCIA SURFACE FROM FLUID-APPLIED APPLICATION 'OVERAGE'.CONTRACTOR WILL BE RESPONSIBLE FOR CLEANING EXCESS OFF METAL AND WALLS.
CONTINUOUS APPLICATION OF POLYURETHANE AND POLYESTERFLUID APPLIED MEMBRANE OVER EXISTING EPDM FIELD MEMBRANE.PRIME ANY EXISTING METAL LIGHTNING ROD BASES WITH 'M' PRIME.CLEAN AND PRIME EPDM SURFACE AS SPECIFIED.
STRUCTURAL METAL DECK
EXISTING MECHANICALLY ATTACHED INSULATION LAYERS
USE MASKING TAPE TO PREVENT FLUID APPLIED SYSTEM FROM ADHERING TO EDGE METAL
KMulti-pipe Portal DetailP
EXISTING MECHANICALLY ATTACHEDINSULATION LAYERS
STRUCTURAL METAL DECK
CONTINUOUS APPLICATION OF POLYURETHANEAND POLYESTER FLUID APPLIED MEMBRANE OVER
EXISTING PORTAL CURB AND BOOTS EXTENDINGFLUID APPLIED SYSTEM UP TO DRAW CLAMP.
CLEAN AND PRIME EPDM SURFACE AS SPECIFIED.
INSPECT AND REPAIR ALL DEFICIENCIES TOPORTAL CAP AND BOOTS WITH 60 MIL.UNCURED NEOPRENE ELASTOMERIC SHEETING
CONTINUOUS APPLICATION OF POLYURETHANEAND POLYESTER FLUID APPLIED MEMBRANEOVER EXISTING EPDM FIELD MEMBRANE.CLEAN AND PRIME EPDM SURFACE AS SPECIFIED.EXTEND FLUID APPLIED SYSTEM UP PORTALBASE TO CAP DRIP EDGE.
INSPECT EXISTING FASTENERS. PROTECT EXISTING METAL COPINGCAP FROM FLUID APPLIED APPLICATION 'OVERAGE'. RECOMMENDAPPLYING PAINTERS MASKING TAPE. CONTRACTOR WILL BERESPONSIBLE FOR CLEANING EXCESS OFF METAL AND WALLS.
file: SD15818c
rev1 10-10-17
General Note:Reuse of sheet metal flashingcomponents reference only appliesto components that are notdamaged during construction process.Damaged components shall be replacedat Contractors expense.
APPLIES TO ALL EXISTING PORTALSAT BOTH HEINEMAN & MARLOWE
1 CONLEY ELEMENTARY SCHOOL - ROOF VENT LOCATIONSNTS
N
1SK3
SK1
Building Technology Consultants, Inc.
1845
Eas
t Ran
d R
oad
, Sui
te L
-100
Arli
ngto
n He
ight
s, Illi
nois
600
04w
ww
.btc
.exp
ert
Con
ley
and
Mac
kebe
n El
emen
tary
Sch
ools
Stee
p Sl
ope
Roof
Rep
lace
men
t and
Ven
tilat
ion
Repa
irs75
0 an
d 8
00 A
cad
emic
Driv
eA
lgon
quin
, Illin
ois,
6010
2
1 MACKEBEN ELEMENTARY SCHOOL - ROOF VENT LOCATIONSNTS
N
1SK3
SK2
Building Technology Consultants, Inc.
1845
Eas
t Ran
d R
oad
, Sui
te L
-100
Arli
ngto
n He
ight
s, Illi
nois
600
04w
ww
.btc
.exp
ert
Con
ley
and
Mac
kebe
n El
emen
tary
Sch
ools
Stee
p Sl
ope
Roof
Rep
lace
men
t and
Ven
tilat
ion
Repa
irs75
0 an
d 8
00 A
cad
emic
Driv
eA
lgon
quin
, Illin
ois,
6010
2
1 TYP. BUILDING SECTIONNTS
3SK6
1SK4
2SK5
4SK7
SK3
Building Technology Consultants, Inc.
1845
Eas
t Ran
d R
oad
, Sui
te L
-100
Arli
ngto
n He
ight
s, Illi
nois
600
04w
ww
.btc
.exp
ert
Con
ley
and
Mac
kebe
n El
emen
tary
Sch
ools
Stee
p Sl
ope
Roof
Rep
lace
men
t and
Ven
tilat
ion
Repa
irs75
0 an
d 8
00 A
cad
emic
Driv
eA
lgon
quin
, Illin
ois,
6010
2
1 SECTION1 1/2" = 1'-0"
SK4
Building Technology Consultants, Inc.
1845
Eas
t Ran
d R
oad
, Sui
te L
-100
Arli
ngto
n He
ight
s, Illi
nois
600
04w
ww
.btc
.exp
ert
Con
ley
and
Mac
kebe
n El
emen
tary
Sch
ools
Stee
p Sl
ope
Roof
Rep
lace
men
t and
Ven
tilat
ion
Repa
irs75
0 an
d 8
00 A
cad
emic
Driv
eA
lgon
quin
, Illin
ois,
6010
2
2 SECTION1 1/2" = 1'-0"
SK5
Building Technology Consultants, Inc.
1845
Eas
t Ran
d R
oad
, Sui
te L
-100
Arli
ngto
n He
ight
s, Illi
nois
600
04w
ww
.btc
.exp
ert
Con
ley
and
Mac
kebe
n El
emen
tary
Sch
ools
Stee
p Sl
ope
Roof
Rep
lace
men
t and
Ven
tilat
ion
Repa
irs75
0 an
d 8
00 A
cad
emic
Driv
eA
lgon
quin
, Illin
ois,
6010
2
3 SECTION1 1/2" = 1'-0"
SK6
Building Technology Consultants, Inc.
1845
Eas
t Ran
d R
oad
, Sui
te L
-100
Arli
ngto
n He
ight
s, Illi
nois
600
04w
ww
.btc
.exp
ert
Con
ley
and
Mac
kebe
n El
emen
tary
Sch
ools
Stee
p Sl
ope
Roof
Rep
lace
men
t and
Ven
tilat
ion
Repa
irs75
0 an
d 8
00 A
cad
emic
Driv
eA
lgon
quin
, Illin
ois,
6010
2
4 SECTION @ TYP. RIDGENTS
SK7
Building Technology Consultants, Inc.
1845
Eas
t Ran
d R
oad
, Sui
te L
-100
Arli
ngto
n He
ight
s, Illi
nois
600
04w
ww
.btc
.exp
ert
Con
ley
and
Mac
kebe
n El
emen
tary
Sch
ools
Stee
p Sl
ope
Roof
Rep
lace
men
t and
Ven
tilat
ion
Repa
irs75
0 an
d 8
00 A
cad
emic
Driv
eA
lgon
quin
, Illin
ois,
6010
2