19
Caledonian 1 Rolling Stock Cable Rolling Stock Cables www.caledonian-cables.co.uk www.addison-cables.com

Rolling Stock Cables Rolling... · RSE/STD/024 Part 6 Rolling Stock Cable..... 29. Caledonian 4 Rolling Stock Cable Caledonian 5 Rolling Stock Cable Single Core, Rubber Sheathed,

  • Upload
    others

  • View
    17

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Rolling Stock Cables Rolling... · RSE/STD/024 Part 6 Rolling Stock Cable..... 29. Caledonian 4 Rolling Stock Cable Caledonian 5 Rolling Stock Cable Single Core, Rubber Sheathed,

Caledonian

1

Rolling Stock Cable

Rolling Stock Cables

www.caledonian-cables.co.ukwww.addison-cables.com

Page 2: Rolling Stock Cables Rolling... · RSE/STD/024 Part 6 Rolling Stock Cable..... 29. Caledonian 4 Rolling Stock Cable Caledonian 5 Rolling Stock Cable Single Core, Rubber Sheathed,

Caledonian

2

Rolling Stock CableCaledonian

3

Rolling Stock Cable

Caledonian & Addison, established in 1978, produced a wide range of copper and fiber optic cables for communication, power and electronics in its 2 plants in UK and 5 plants in China, with turnover exceeding USD exceeding USD 40 million in Yr 2004. Caledonian products are sold in more than 35 countries around the globe. Our extensive global network of manufacturing facilities gives us significant scale and the flexibility to fulfill our customer requirements. This global presence provides design and consultancy solutions that are combined with core cable manufacturing and logistics services, and vertically integrated with our E commerce technologies to optimize customer operations by lowering costs and reducing time to market. Caledonian & Addison has been respected for its high standards of quality, excellent service level, competitive pricing and a unique and innovative spirit. With our latest technologies, we are both inspired and well-positioned to meet the changing needs of our customers. We have the resources to diversify and to enhance our product lines and services. We understand the need for change and with our accurate planning we are ready for the future and the promise of new marketing opportunities. Our tradition of growth through excellence is assured.

Our Design Centers work closely with customers to constantly improve its standard range of products and technologies and to develop customized, country and industry-specific solutions.

Caledonian has established an extensive network of design, manufacturing, and logistics facilities in the world's major markets toserve the growing outsourcing needs of both multinational and regional customers.

Rolling Stock Cable

Table of ContentSINGLE CORE

Ruber Type, Unscreened Cable .................................................................... 4

LSOH Type, Unscreened Cable .................................................................... 7

LSOH Type, Screened Cable ...................................................................... 15

MULTI CORE

Ruber Type, Unscreened Cable ................................................................. 20

LSOH Type, Unscreened Cable ................................................................. 21

DATABUS RS 485 CABLE

Databus RS 485 Cable ................................................................................ 27

RSE/STD/024 PART 6 ROLLING STOCK CABLE

RSE/STD/024 Part 6 Rolling Stock Cable...................................................... 29

Page 3: Rolling Stock Cables Rolling... · RSE/STD/024 Part 6 Rolling Stock Cable..... 29. Caledonian 4 Rolling Stock Cable Caledonian 5 Rolling Stock Cable Single Core, Rubber Sheathed,

Caledonian

4

Rolling Stock CableCaledonian

5

Rolling Stock CableSingle Core, Rubber Sheathed, Unscreened Cable

Voltage Cable Type ConstructionNumber

of Cores

Cross Sectional Areas/Stranding

Class

Design Standard

Fire Standard

300/500VSingle Core,

unsheathed

CU/EPR-CSP dual insulation

1C 1.0mm 2 -16mm

2, Class 5 Stranding N/A N/A

650/750VSingle Core,

unsheathedCU/EPR 1C 150mm2-1000mm2,

Class 2 StrandingRT/E/

S/21101 N/A

600/1000VSingle Core,

unsheathed

CU/EPR-CSP dual insulation

1C 1.0mm2-400mm2, Class 5 Stranding N/A N/A

1800/3000VSingle Core,

unsheathed

CU/EPR-CSP dual insulation

1C 1.0mm2-400mm2 , Class 5 Stranding N/A N/A

300/500V Singlecore rubber cable, unsheathed

Cross sectional Area 1mm2 -16 mm2

Voltage rating 300/500VConductor Flexible Stranded Tinned Copper

Number of cores 1Conductor class IEC 60228 Class 5

Insulation EPR/CSP Dual Insulation

No. of Cores/PairsCross

Sectional Area(mm2)

Number and Nominal Diameter of

Strands(mm)

Voltage Rating(V)

Nominal Overall

Diameter (mm)

Nominal Weight (kg/km)

Singlecore 1.0 32/0.2 300/500 3.3 22.5Singlecore 1.5 30/0.25 300/500 3.6 28.4Singlecore 2.5 50/0.25 300/500 4.2 41.5Singlecore 4.0 56/0.3 300/500 5.0 61.0Singlecore 6.0 84/0.3 300/500 6.1 88.8Singlecore 10.0 80/0.4 300/500 7.5 141.0Singlecore 16.0 126/0.4 300/500 8.6 204.0

600/1000V Singlecore rubber cable, unsheathed

Cross sectional Area 1mm2 -400 mm2

Voltage rating 600/1000VConductor Flexible Stranded Tinned Copper

Number of cores 1Conductor class IEC 60228 Class 5

Insulation EPR/CSP Dual Insulation

No of Cores/Pairs

Cross Sectional

Area(mm2)

Number and Nominal Diameter

of Strands(mm)

Voltage Rating(V)

Nominal Overall

Diameter (mm)

Nominal Weight (kg/km)

Singlecore 1.0 32/0.2 600/1000 4.5 35Singlecore 1.5 30/0.25 600/1000 4.8 40.7Singlecore 2.5 50/0.25 600/1000 5.0 52.9Singlecore 4.0 56/0.3 600/1000 6.9 72.7Singlecore 6.0 84/0.3 600/1000 7.1 104.0Singlecore 10.0 80/0.4 600/1000 8.1 152.0Singlecore 16.0 126/0.4 600/1000 9.2 217.0Singlecore 25.0 196/0.4 600/1000 10.9 322.0Singlecore 35.0 276/0.4 600/1000 12.3 430.0Singlecore 50.0 396/0.4 600/1000 14.3 596.0Singlecore 70.0 360/0.5 600/1000 16.6 807.0Singlecore 95.0 476/0.5 600/1000 19.1 1054.0Singlecore 120.0 608/0.5 600/1000 21.2 1345.0Singlecore 150.0 756/0.5 600/1000 23.4 1648.0Singlecore 185.0 925/0.5 600/1000 25.6 1992.0Singlecore 240.0 1221/0.5 600/1000 28.6 2567.0Singlecore 300.0 1525/0.5 600/1000 30.9 3179.0Singlecore 400.0 2013/0.5 600/1000 34.9 4129.0

650/750V Singlecore rubber cable, unsheathed

Cross-sectional Area 150mm2 -1000mm2

Voltage rating 650/750VConductor Flexible Stranded Aluminum Copper

Number of cores 1Conductor class IEC 60228 Class 5

Insulation EPRRailway standard RT/E/S/21101

No. of Cores/Pairs

Cross Sectional Area

(mm2)

Number and Nominal

Diameter of Strands (mm)

Voltage Rating

(V)

Nominal Overall Diameter

(mm)

Nominal Weight

(kg/km)Singlecore 150.0 37/2.25 650/750 20.5 581.0Singlecore 161.0 91/1.53 650/750 25.9 2050.0Singlecore 240.0 61/2.25 650/750 29.6 1177.0Singlecore 500.0 61/3.2 650/750 42.0 2361.0Singlecore 500.0 91/2.65 650/750 42.3 6682.0Singlecore 630.0 127/2.52 650/750 45.9 6879.0Singlecore 800.0 127/2.85 650/750 50.2 3498.0Singlecore 1000.0 127/3.2 650/750 55.0 4226.0

Page 4: Rolling Stock Cables Rolling... · RSE/STD/024 Part 6 Rolling Stock Cable..... 29. Caledonian 4 Rolling Stock Cable Caledonian 5 Rolling Stock Cable Single Core, Rubber Sheathed,

Caledonian

6

Rolling Stock CableCaledonian

7

Rolling Stock Cable650/750V Singlecore rubber cable, unsheathed

Cross-sectional Area 1.0mm2-400mm2

Voltage rating 1800/3000VConductor Flexible Stranded Tinned Copper

Number of cores 1Conductor class IEC 60228 Class 5

Insulation EPR/CSP Dual Insulation

No of Cores/Pairs

Cross Sectional Area

(mm2)

Number and Nominal Diameter

of Strands(mm)

Voltage Rating(V)

Nominal Overall

Diameter (mm)

Nominal Weight (kg/km)

Singlecore 1.0 32/0.2 1800/3000 7.5 84Singlecore 1.5 30/0.25 1800/3000 7.8 90.7Singlecore 2.5 50/0.25 1800/3000 8.05 100.0Singlecore 4.0 56/0.3 1800/3000 8.5 122.0Singlecore 6.0 84/0.3 1800/3000 9.9 154.0Singlecore 10.0 80/0.4 1800/3000 10.7 216.0Singlecore 16.0 126/0.4 1800/3000 11.85 288.0Singlecore 25.0 196/0.4 1800/3000 13.25 392.0Singlecore 35.0 276/0.4 1800/3000 14.65 509.0Singlecore 50.0 396/0.4 1800/3000 16.5 682.0Singlecore 70.0 360/0.5 1800/3000 18.6 894.0Singlecore 95.0 476/0.5 1800/3000 21.25 1168.0Singlecore 120.0 608/0.5 1800/3000 22.75 1433.0Singlecore 150.0 756/0.5 1800/3000 24.75 1434.0Singlecore 185.0 925/0.5 1800/3000 26.75 2073.0Singlecore 240.0 1221/0.5 1800/3000 28.75 2657.0Singlecore 300.0 1525/0.5 1800/3000 32.9 3279.0Singlecore 400.0 2013/0.5 1800/3000 36.9 4229.0

Single Core, LSOH Sheathed, Unscreened Cable

Voltage Cable Type ConstructionNumber

of Cores

Cross Sectional Areas/Stranding

Class

Design Standard Fire Standard

300/500V Single Core, unsheathed CU/EI 107 EPR 1C

10 AWG-20AWG 19/37 Standing

0.5mm2- 4mm2, Class 5 Stranding

EN 50264-3-1

EN 50267-2-1/2, EN50305, EN 50305, EN 50268-2, BS6853,

DIN 5510 P1, HAZARD LEVEL 1-4

300/500V Single Core, with jacket

CU/EI107 EPR/EM 104 EVA 1C 1.0mm2-400mm2,

Class 5 Stranding TM1 -05 BS 6853A/B/II, NF F 16 101

600/1000V Single Core, unsheathed CU/EI 107 EPR 1C 0.5mm2- 400mm2 ,

Class 5 StrandingEN

50264-3-1

EN 50267-2-1/2, EN50305, EN 50305, EN 50268-2, BS6853,

DIN 5510 P1, HAZARD LEVEL 1-4

600/1000V Single Core, with jacket

CU/EI107 EPR/EM 104 EVA 1C 1.0mm2-400mm2,

Class 5 Stranding TM1 -05 BS 6853A/B/II, NF F 16 101

600/1000VSingle Core, unsheathed fire resistant

CU/MICA/EI107 EVA 1C 1.5mm2-400mm2, Class 5 Stranding

EN 50264-3-1

EN 50267-2-1/2, EN50305, EN 50305, EN 50268-2, BS6853,

DIN 5510 P1, HAZARD LEVEL 1-4,

EN 50200 (15MIN)

600/1000VSingle Core,

with jacket fire resistant

CU/MICA/EI107 EPR/EM 104 EVA 1C 1.5mm2-16mm2,

Class 5 StrandingEN

50264-3-1

EN 50267-2-1/2, EN50305, EN 50305, EN 50268-2, BS6853,

DIN 5510 P1, HAZARD LEVEL 1-4,

EN 50200 (15MIN)

1800/3000V Single Core, unsheathed CU/EI 107 EPR 1C 25mm2-400mm2,

Class 5 StrandingEN

50264-3-1

EN 50267-2-1/2, EN50305, EN 50305, EN 50268-2, BS6853,

DIN 5510 P1, HAZARD LEVEL 1-4

1800/3000V Single Core, with jacket

CU/EI 110 EPR/EI 104 EPR 1C 25mm2-400mm2,

Class 5 StrandingEN

50264-3-1

EN 50267-2-1/2, EN50305, EN 50305, EN 50268-2, BS6853,

DIN 5510 P1, HAZARD LEVEL 1-4

3600/6000V Single Core, unsheathed

CU/EI 104 EPR/EM 104 EVA 1C 1.0mm2-400mm2,

Class 5 StrandingEN

50264-3-1

BS 6853A/B/II, NEN 50267-2-1/2,

EN50305, EN 50305, EN 50268-2, BS6853,

DIN 5510 P1, HAZARD LEVEL 1-4F

F 16 101

3600/6000V Single Core, with jacket

CU/EI 104 EPR/EM 104 EVA 1C 1.0mm2-400mm2,

Class 5 StrandingEN

50264-3-1

EN 50267-2-1/2, EN50305, EN 50305, EN 50268-2, BS6853,

DIN 5510 P1, HAZARD LEVEL 1-4

Page 5: Rolling Stock Cables Rolling... · RSE/STD/024 Part 6 Rolling Stock Cable..... 29. Caledonian 4 Rolling Stock Cable Caledonian 5 Rolling Stock Cable Single Core, Rubber Sheathed,

Caledonian

8

Rolling Stock CableCaledonian

9

Rolling Stock Cable300/500V Singlecore LSOH rubber cable unsheathed

Cross-sectional Area 10AWG-20AWG- 0.5mm2 -4 mmsqVoltage rating 300/500V

Conductor Flexible Stranded Tinned CopperNumber of cores 1Conductor class 19/37 AWG Standing

Insulation Cross linked EPR rubber type EI 107 or equivalent, in accordance with EN 50264-1

Fire standard BS 6853 Categories la, lb and ll and NF F 16 101 FO

No of Cores/Pairs

Cross Sectional Area

(mm2)

Number and Nominal Diameter

of Strands (mm)

Voltage Rating

(V)

Nominal Overall

Diameter(mm)

Nominal Weight

(kg/km)Singlecore 0.5 16/0.2 300/500 1.8 7.5Singlecore 0.75 24/0.2 300/500 1.9 11Singlecore 1.0 32/0.2 300/500 2.2 13Singlecore 1.5 30/0.25 300/500 2.6 19Singlecore 2.5 50/0.25 300/500 3.0 29Singlecore 4.0 56/0.3 300/500 3.7 47

No of Cores/Pairs

Cross Sectional Area

(mm2)

Number and Nominal Diameter

of Strands (mm)

Voltage Rating

(V)

Nominal Overall Diameter

(mm)

Nominal Weight

(kg/km)Singlecore 20 19/0.2 300/500 1.5 6.8Singlecore 18 19/0.25 300/500 1.75 10.1Singlecore 16 19/0.3 300/500 2.0 14.2Singlecore 14 37/0.25 300/500 2.35 19.3Singlecore 12 37/0.3 300/500 2.77 27.5Singlecore 10 37/0.4 300/500 3.45 47.1Singlecore 18 19/0.25 300/500 2.7 19.4

300/500V Single Core LSOH rubber cable with jacket

Cross-sectional Area 1mm2-400mm2

Voltage rating 300/500VConductor Flexible Stranded Tinned Copper

Number of cores 1Conductor class IEC 60228 Class 5

Insulation Cross linked EPR, rubber type EI110 or equivalent, in accordance with EN 50264-1

Jacket Cross linked EVA, rubber type EM104 or equivalent, in accordance with EN50264-1

Fire standard BS 6853 Categories la, lb and ll and NFF 16 101 FO

No of Cores/Pairs

Cross Sectional Area

(mm2)

Number and Nominal

Diameter of Strands

(mm)

Voltage Rating(V)

Nominal Overall

Diameter (mm)

Nominal Weight (kg/km)

Singlecore 1.0 32/0.20 300/500 5.9 54.0Singlecore 1.5 30/0.75 300/500 6.2 60.0Singlecore 2.5 50/0.25 300/500 6.6 74.0Singlecore 4.0 56/0.30 300/500 7.2 94.0Singlecore 6.0 84/0.30 300/500 7.7 124.0Singlecore 10.0 80/0.40 300/500 9.1 179.0Singlecore 16.0 126/0.40 300/500 10.2 248.0Singlecore 25.0 196/0.40 300/500 11.6 352.0Singlecore 35.0 276/0.40 300/500 13.1 454.0Singlecore 50.0 396/0.40 300/500 14.9 619.0Singlecore 70.0 360/0.50 300/500 17.0 838.0Singlecore 95.0 475/0.50 300/500 19.0 1077.0Singlecore 120.0 608/0.50 300/500 21.1 1352.0Singlecore 150.0 756/0.50 300/500 22.9 1648.0Singlecore 185.0 925/0.50 300/500 24.9 1989.0Singlecore 240.0 1221/0.50 300/500 28.0 2585.0Singlecore 300.0 1525/0.50 300/500 31.8 3229.0Singlecore 400.0 2013/0.50 300/500 35.1 4165.0

600/1000V Singlecore LSOH rubber cable, unsheathed

Cross-sectional Area 0.5mm2-400mm2

Voltage rating 600/1000VConductor Flexible Stranded Tinned Copper

Number of cores 1Conductor class IEC 60228 Class 5

Insulation Cross linked EPR rubber type EI 107 or equivalent, in accordance with EN 50264-1Fire standard BS 6853 Categories la, lb and ll and NFF 16 101 FO

Page 6: Rolling Stock Cables Rolling... · RSE/STD/024 Part 6 Rolling Stock Cable..... 29. Caledonian 4 Rolling Stock Cable Caledonian 5 Rolling Stock Cable Single Core, Rubber Sheathed,

Caledonian

10

Rolling Stock CableCaledonian

11

Rolling Stock Cable

No. of Cores/Pairs

Cross Sectional Area(mm2)

Number and Nominal

Diameter of Strands

(mm)

Voltage Rating(V)

Nominal Overall

Diameter (mm)

Nominal Weight (kg/km)

Singlecore 0.5 32/0.20 600/1000 2.2 7.5Singlecore 0.75 30/0.75 600/1000 2.3 11Singlecore 1 50/0.25 600/1000 2.6 13Singlecore 1.5 56/0.30 600/1000 3.0 19Singlecore 2.5 84/0.30 600/1000 3.4 29Singlecore 4 80/0.40 600/1000 4.1 47Singlecore 6 126/0.40 600/1000 4.6 70Singlecore 10 196/0.40 600/1000 5.7 110Singlecore 16 276/0.40 600/1000 6.8 170Singlecore 25 396/0.40 600/1000 8.4 270Singlecore 35 360/0.50 600/1000 9.5 360Singlecore 50 475/0.50 600/1000 11.6 520Singlecore 70 608/0.50 600/1000 13.5 700Singlecore 95 756/0.50 600/1000 15.3 900Singlecore 120 925/0.50 600/1000 16.4 1130Singlecore 150 1221/0.50 600/1000 19.0 1470Singlecore 185 1525/0.50 600/1000 21.3 1770Singlecore 240 2013/0.50 600/1000 24.2 2310Singlecore 300 1525/0.5 600/1000 27.8 3029Singlecore 400 2013/0.2 600/1000 31.1 3905

600/1000V Singlecore LSOH rubber cable with jacket

Cross-sectional Area 1.0mm2 -400mm2

Voltage rating 600/1000VConductor Flexible Stranded Tinned Copper

Number of cores 1Conductor class IEC 60228 Class 5

Insulation Cross linked EPR rubber type EI 110 or equivalent, in accordance with EN 50264-1

Jacket Cross linked EVA rubber type EM104 or equivalent, in accordance with EN 50264-1

Fire standard BS 6853 Categories la, lb and ll and NFF 16 101 FO

No. of Cores/Pairs

Cross Sectional Area(mm2)

Number and Nominal

Diameter of Strands

(mm)

Voltage Rating(V)

Nominal Overall

Diameter (mm)

Nominal Weight (kg/km)

Singlecore 1.0 32/0.20 600/1000 5.9 54.0Singlecore 1.5 30/0.75 600/1000 6.2 60.0Singlecore 2.5 50/0.25 600/1000 6.6 74.0Singlecore 4.0 56/0.30 600/1000 7.2 94.0Singlecore 6.0 84/0.30 600/1000 7.7 124.0Singlecore 10.0 80/0.40 600/1000 9.1 129.0Singlecore 16.0 126/0.40 600/1000 10.2 248.0Singlecore 25.0 196/0.40 600/1000 11.6 352.0Singlecore 35.0 276/0.40 600/1000 13.1 454.0Singlecore 50.0 396/0.40 600/1000 14.9 619.0Singlecore 70.0 360/0.50 600/1000 17.0 838.0Singlecore 95.0 475/0.50 600/1000 19.0 1077.0Singlecore 120.0 608/0.50 600/1000 21.1 1352.0Singlecore 150.0 756/0.50 600/1000 22.9 1648.0Singlecore 185.0 925/0.50 600/1000 24.9 1989.0Singlecore 240.0 1221/0.50 600/1000 28.0 2585.0Singlecore 300.0 1525/0.50 600/1000 31.8 3229.0Singlecore 400.0 2013/0.50 600/1000 35.5 4165.0

600/1000V Singlecore fire resistant rubber cable ,unsheathed

Cross-sectional 1.5mm2-16mm2

Voltage rating 600/1000VConductor Flexible Stranded Tinned copper

Number of cores 1Conductor class IEC 60228 Class 5Flame Bannier Mica tape

Insulation Cross linked EPR rubber type EI 110 or equivalent, in accordance with EN 50264-1Fire standard BS 6853 Categories la, lb and ll and NFF 16 101 FO

No of Cores/Pairs

Cross Sectional

Area(mm2)

Number and Nominal

Diameter of Strands (mm)

Voltage Rating(V)

Nominal Overall

Diameter (mm)

Nominal Weight (kg/km)

Singlecore 1.5 56/0.3 600/1000 4.0 21Singlecore 2.5 84/0.3 600/1000 4.4 32Singlecore 4.0 80/0.4 600/1000 5.3 55Singlecore 6.0 126/0.4 600/1000 5.8 80Singlecore 10.0 196/0.4 600/1000 7.5 170Singlecore 16.0 276/0.4 600/1000 9.0 190

Page 7: Rolling Stock Cables Rolling... · RSE/STD/024 Part 6 Rolling Stock Cable..... 29. Caledonian 4 Rolling Stock Cable Caledonian 5 Rolling Stock Cable Single Core, Rubber Sheathed,

Caledonian

12

Rolling Stock CableCaledonian

13

Rolling Stock Cable600/1000V Singlecore fire resistant rubber cable with jacket

Cross-sectional 1.5mm2-16mm2

Voltage rating 600/1000VConductor Flexible Stranded Tinned Copper

Number of cores 1Conductor class IEC 60228 Class 5Flame Bannier Mica tape

Insulation Cross linked EPR rubber type EI 107 or equivalent, in accordance with EN 50264-1Jacket Cross linked EVA rubber type EM104 or equivalent ,in accordance with EN 50264-1

Fire standard Cross linked RVR rubber type EI 107 or equivalent, in accordance with EN 50264-1

No of Cores/Pairs

Cross Sectional

Area(mm2)

Number and Nominal Diameter

of Strands (mm)

Voltage Rating(V)

Nominal Overall

Diameter (mm)

Nominal Weight (kg/km)

Singlecore 1.5 56/0.3 600/1000 7.2 63Singlecore 2.5 84/0.3 600/1000 7.6 77Singlecore 4.0 80/0.4 600/1000 8.3 101Singlecore 6.0 126/0.4 600/1000 8.9 134Singlecore 10.0 196/0.4 600/1000 10.5 189Singlecore 16.0 276/0.4 600/1000 12 258

1800/3000V Single Core LSOH rubber cable unsheathed

Cross-sectional Area 25mm2-400mm2 Voltage rating 1800/3000V

Conductor Flexible Stranded Tinned Copper Number of cores 1Conductor class IEC 60228 Class 5

Insulation Cross linked EPR rubber type EI 107 or equivalent, in accordance with EN 50264-1 Fire standard BS 6853 Categories la, lb and ll and NFF 16 101 FO

No of Cores/Pairs

Cross Sectional Area(mm2)

Number and Nominal Diameter

of Strands(mm)

Voltage Rating

(V)

Nominal Overall

Diameter(mm)

Nominal Weight

(kg/km)Singlecore 25 80/0.4 1800/3000 10.6 282Singlecore 35 126/0.4 1800/3000 11.7 388Singlecore 50 196/0.4 1800/3000 13.6 661Singlecore 70 276/0.4 1800/3000 15.6 747Singlecore 95 396/0.4 1800/3000 17.3 975Singlecore 120 360/0.5 1800/3000 19.6 1229Singlecore 150 476/0.5 1800/3000 21.9 1538Singlecore 185 608/0.5 1800/3000 23.8 1859Singlecore 240 756/0.5 1800/3000 26.9 2444Singlecore 300 925/0.5 1800/3000 29.8 3031Singlecore 400 1221/0.5 1800/3000 32.3 3987

1800/3000V Single Core LSOH rubber cable with jacket

Cross- sectional Area 2.5mm2-400mm2

Voltage rating 1800/3000VConductor Flexible Stranded Tinned Copper

Number of cores 1Conductor class IEC 60228 Class 5

Insulation Cross linked EPR rubber type EI 107 or equivalent, in accordance with EN 50264-1

Jacket Cross linked EVA rubber type EM 104 or equivalent ,in accordance with EN 50264-1

Fire standard BS 6853 Categories la, lb and ll and NFF 16 101 FO

No of Cores/Pairs

Cross Sectional

Area(mm2)

Number and Nominal Diameter

of Strands(mm)

Voltage Rating

(V)

Nominal Overall

Diameter (mm)

Nominal Weight(kg/km)

Singlecore 2.5 32/0.2 1800/3000 6.2 75.8Singlecore 4 30/0.25 1800/3000 6.8 97.0Singlecore 6 50/0.25 1800/3000 7.4 128.0Singlecore 10 56/0.3 1800/3000 8.7 177.0Singlecore 16 84/0.3 1800/3000 9.8 244.0Singlecore 25 80/0.4 1800/3000 12.3 344.0Singlecore 35 126/0.4 1800/3000 13.3 459.0Singlecore 50 196/0.4 1800/3000 14.6 618.0Singlecore 70 276/0.4 1800/3000 16.7 821.0Singlecore 95 396/0.4 1800/3000 19.2 1068.0Singlecore 120 360/0.5 1800/3000 20.8 1332.0Singlecore 150 476/0.5 1800/3000 22.9 1621.0Singlecore 185 608/0.5 1800/3000 25.0 1948.0Singlecore 240 756/0.5 1800/3000 27.9 1948.0Singlecore 300 925/0.5 1800/3000 30.6 3100.0Singlecore 400 1221/0.5 1800/3000 34.2 4035.0

Page 8: Rolling Stock Cables Rolling... · RSE/STD/024 Part 6 Rolling Stock Cable..... 29. Caledonian 4 Rolling Stock Cable Caledonian 5 Rolling Stock Cable Single Core, Rubber Sheathed,

Caledonian

14

Rolling Stock CableCaledonian

15

Rolling Stock Cable3600/6000V Single Core LSOH rubber cable unsheathed

Cross- sectional Area 25mm2-400mm2

Voltage rating 3600/6000VConductor Flexible Stranded Tinned Copper

Number of cores 1Conductor class IEC 60228 Class 5

Insulation Cross linked EVA rubber type EI 107 or equivalent ,in accordance with EN 50264-1Fire standard BS 6853 Categories la, lb and ll and NFF 16 101 FO

No. of Cores/Pairs

Cross Sectional

Area(mm2)

Number and

Nominal Diameter

of Strands (mm)

Voltage Rating

(V)

Nominal Overall Diameter

(mm)

Nominal Weight

(kg/km)

Singlecore 25 80/0.4 1800/3000 10.6 282Singlecore 35 126/0.4 1800/3000 11.7 388Singlecore 50 196/0.4 1800/3000 13.6 661Singlecore 70 276/0.4 1800/3000 15.6 747Singlecore 95 396/0.4 1800/3000 17.3 975Singlecore 120 360/0.5 1800/3000 19.6 1229Singlecore 150 476/0.5 1800/3000 21.9 1538Singlecore 185 608/0.5 1800/3000 23.8 1859Singlecore 240 756/0.5 1800/3000 26.9 2444Singlecore 300 925/0.5 1800/3000 29.8 3031Singlecore 400 1221/0.5 1800/3000 32.3 3987

3600/6000V Single Core with jacket rubber cable

Cross- sectional Area 2.5mm2-400mm2

Voltage rating 3600/1000VConductor Flexible Stranded Tinned Copper

Number of cores 1Conductor class IEC 60228 Class 5

Insulation Cross linked EPR rubber type EI 107 or equivalent, in accordance with EN 50264-1Jacket Cross linked EVA rubber type EM 104 or equivalent, in accordance with EN 50264-1

Fire standard BS 6853 Categories la, lb and ll and NFF 16 101 FO

No. of Cores/Pairs

Cross Sectional Area

(mm2)

Number and Nominal Diameter

of Strands(mm)

Voltage Rating(V)

Nominal Overall

Diameter (mm)

Nominal Weight (kg/km)

Singlecore 2.5 32/0.2 3600/1000 6.2 75.8Singlecore 4 30/0.25 3600/1000 6.8 97.0Singlecore 6 50/0.25 3600/1000 7.4 128.0Singlecore 10 56/0.3 3600/1000 8.7 177.0Singlecore 16 84/0.3 3600/1000 9.8 244.0Singlecore 25 80/0.4 3600/1000 12.3 344.0Singlecore 35 126/0.4 3600/1000 13.3 459.0Singlecore 50 196/0.4 3600/1000 14.6 618.0Singlecore 70 276/0.4 3600/1000 16.7 821.0Singlecore 95 396/0.4 3600/1000 19.2 1068.0Singlecore 120 360/0.5 3600/1000 20.8 1332.0Singlecore 150 476/0.5 3600/1000 22.9 1621.0Singlecore 185 608/0.5 3600/1000 25.0 1948.0Singlecore 240 756/0.5 3600/1000 27.9 1948.0Singlecore 300 925/0.5 3600/1000 30.6 3100.0Singlecore 400 1221/0.5 3600/1000 34.2 4035.0

Single Core, LSOH Sheathed, Screened Cable

Voltage Cable Type ConstructionNumber

of Cores

Cross Sectional Areas/Stranding

Class

Design Standard Fire Standard

300/500VSingle Core

screened, with jacket

CU/EI 110 EPR/CUTO/EM 104

EVA1C

2.5mm2- 25mm2, Class 5 Stranding

EN 50264-3-1

EN 50267-2-1/2, EN50305, EN

50305, EN 50268-2, BS6853, DIN 5510

P1, HAZARD LEVEL 1-4

600/1000VSingle Core

screened, with jacket

CU/EI 110 EPR/CUTO/EM 104

EVA1C

2.5mm2- 25mm2, Class 5 Stranding

EN 50264-3-1

EN 50267-2-1/2, EN50305, EN

50305, EN 50268-2, BS6853, DIN 5510

P1, HAZARD LEVEL 1-4

1800/3000VSingle Core

screened, with jacket

CU/EI 110 EPR/CUTO/EM 104

EVA1C

1.0mm2-300mm2, Class 5 Stranding

EN 50264-3-1

EN 50267-2-1/2, EN50305, EN

50305, EN 50268-2, BS6853, DIN 5510

P1, HAZARD LEVEL 1-4

3600/6000VSingle Core

screened, with jacket

CU/EI 104 EPR/CUTO/EM

104 EVA1C

1.0mm2-400mm2, Class 5 Stranding

EN 50264-1,2,3

EN 50267-2-1/2, EN50305, EN

50305, EN 50268-2, BS6853, DIN 5510

P1, HAZARD LEVEL 1-4

Page 9: Rolling Stock Cables Rolling... · RSE/STD/024 Part 6 Rolling Stock Cable..... 29. Caledonian 4 Rolling Stock Cable Caledonian 5 Rolling Stock Cable Single Core, Rubber Sheathed,

Caledonian

16

Rolling Stock CableCaledonian

17

Rolling Stock Cable300/500V Single Core screened LSOH rubber cable with jacket

Cross-sectional Area 2.5mm2-25mm2

Voltage rating 300/500VConductor Flexible Stranded Tinned Copper

Number of cores 1Conductor class IEC 60228 Class 5

Insulation Cross linked EPR rubber type EI 110 or equivalent, in accordance with EN 50264-1Screen Tinned Copper BraidJacket Cross linked EVA rubber type EM 104 or equivalent, in accordance with EN 50264-1

Fire Standard BS 6853-la,DIN 5510-1 1-4.NF F 16-101 FO

No of Cores/Pairs

Cross Sectional Area

(mm2)

Number and Nominal Diameter of Strands (mm)

Voltage Rating(V)

Nominal Overall

Diameter (mm)

Nominal Weight (kg/km)

Singlecore 2.5 50/0.25 300/500 5.6 74Singlecore 4 56/0.3 300/500 6.2 94Singlecore 6 84/0.3 300/500 7.2 124Singlecore 10 80/0.4 300/500 8.6 179Singlecore 16 126/0.4 300/500 9.6 248Singlecore 25 196/0.4 300/500 11.5 352

600/1000V Single Cores creened LSOH rubber cable with jacket

Cross- sectional Area 2.5mm2-25mm2

Voltage rating 6001000VConductor Flexible Stranded Tinned Copper

Number of cores 1Conductor class IEC 60228 Class 5

Insulation Cross linked EPR rubber type EI 110 or equivalent, in accordance with EN 50264-1Screen Tinned Copper BraidJacket Cross linked EVA rubber type EM 104 or equivalent, in accordance with EN

50264-1Fire Standard BS 6853-la,DIN 5510-1 1-4.NF F 16-101 FO

No. of Cores/Pairs

Cross Sectional Area

(mm2)

Number and Nominal Diameter

of Strands (mm)

Voltage Rating(V)

Nominal Overall

Diameter (mm)

Nominal Weight (kg/km)

Singlecore 2.5 50/0.25 300/500 5.6 74Singlecore 4 56/0.3 300/500 6.2 94Singlecore 6 64/0.3 300/500 7.2 124Singlecore 10 80/0.4 300/500 8.6 179Singlecore 16 126/0.4 300/500 9.6 248Singlecore 25 196/0.4 300/500 11.8 352

1800/3000V Single Core screened LSOH rubber cable with jacket

Cross- sectional Area 2.5mm2-400 mm2

Voltage rating 1800/3000VConductor Flexible Stranded Tinned Copper

Number of cores 1Conductor class IEC 60228 Class 5

Insulation Cross linked EPR rubber type EI 110 or equivalent, in accordance with EN 50264-1

Screen Tinned Copper Braid

Jacket Cross linked EVA rubber type EM 104 or equivalent, in accordance with EN 50264-1

Fire Standard BS 6853-la, DIN 5510-1 1-4.NF F 16-101 FO

No. of Cores/Pairs

Cross Sectional

Area(mm2)

Number and Nominal Diameter

of Strands (mm)

Voltage Rating(V)

Nominal Overall

Diameter (mm)

Nominal Weight (kg/km)

Singlecore 2.5 32/0.2 1800/3000 6.2 75.8Singlecore 4 30/0.25 1800/3000 6.8 97.0Singlecore 6 50/0.25 1800/3000 7.4 128.0Singlecore 10 56/0.3 1800/3000 8.7 177.0Singlecore 16 84/0.3 1800/3000 9.8 244.0Singlecore 25 80/0.4 1800/3000 12.3 344.0Singlecore 35 126/0.4 1800/3000 13.3 459.0Singlecore 50 196/0.4 1800/3000 14.6 618.0Singlecore 70 276/0.4 1800/3000 16.7 821.0Singlecore 95 396/0.4 1800/3000 19.2 1068.0Singlecore 120 360/0.5 1800/3000 20.8 1332.0Singlecore 150 476/0.5 1800/3000 22.9 1621.0Singlecore 185 608/0.5 1800/3000 25.0 1948.0Singlecore 240 756/0.5 1800/3000 27.9 1948.0Singlecore 300 925/0.5 1800/3000 30.6 3100.0Singlecore 400 1221/0.5 1800/3000 34.2 4035.0

3600/6000V Single Core LSOH rubber cable with jacket

Cross-sectional Area 2.5mm2-400mm2

Voltage rating 3600/6000VConductor Flexible Stranded Tinned Copper

Number of cores 1Conductor class IEC 60228 Class 5

Insulation Cross linked EPR rubber type EI 110 or equivalent, in accordance with EN 50264-1Screen Tinned Copper BraidJacket Cross linked EVA rubber type EM 104 or equivalent, in accordance with EN 50264-1

Fire Standard BS 6853-la,DIN 5510-1 1-4.NF F 16-101 FO

Page 10: Rolling Stock Cables Rolling... · RSE/STD/024 Part 6 Rolling Stock Cable..... 29. Caledonian 4 Rolling Stock Cable Caledonian 5 Rolling Stock Cable Single Core, Rubber Sheathed,

Caledonian

18

Rolling Stock CableCaledonian

19

Rolling Stock Cable

No. of Cores/Pairs

Cross Sectional

Area(mm2)

Number and Nominal Diameter

of Strands(mm)

Voltage Rating

(V)

Nominal Overall

Diameter (mm)

Nominal Weight (kg/km)

Singlecore 2.5 32/0.2 3600/1000 6.2 75.8Singlecore 4 30/0.25 3600/1000 6.8 97.0Singlecore 6 50/0.25 3600/1000 7.4 128.0Singlecore 10 56/0.3 3600/1000 8.7 177.0Singlecore 16 84/0.3 3600/1000 9.8 244.0Singlecore 25 80/0.4 3600/1000 12.3 344.0Singlecore 35 126/0.4 3600/1000 13.3 459.0Singlecore 50 196/0.4 3600/1000 14.6 618.0Singlecore 70 276/0.4 3600/1000 16.7 821.0Singlecore 95 396/0.4 3600/1000 19.2 1068.0Singlecore 120 360/0.5 3600/1000 20.8 1332.0Singlecore 150 476/0.5 3600/1000 22.9 1621.0Singlecore 185 608/0.5 3600/1000 25.0 1948.0Singlecore 240 756/0.5 3600/1000 27.9 1948.0Singlecore 300 925/0.5 3600/1000 30.6 3100.0Singlecore 400 1221/0.5 3600/1000 34.2 4035.0

Multi Core/Pair, Rubber/LSOH Sheathed, Unscreened Cable

Rubber Type

Voltage Cable Type ConstructionNumber

of Cores

Cross Sectional Areas/Stranding

Class

Design Standard

Fire Standard

300/500V Multicore, with jacket CU/EPR/PCP 1,2,3 Prs 1.0mm2-4.0mm2 N/A N/A

600/1000V Multipair, with jacket CU/EPR/PCP 12-42C 1.0mm2-4.0mm 2 N/A N/A

LSOH Type

Voltage Cable Type ConstructionNumber

of Cores

Cross Sectional Areas/Stranding

Class

Design Standard Fire Standard

300/500VMulticore,

with jacketCU/EI 110 EPR/EM

104 EVA1-21C

0.75mm2 - 6mm2, Class 5 Stranding

EN 50264-3-2

EN 50267-2-1/2, EN50305, EN 50305, EN 50268-2, BS6853, DIN 5510 P1, HAZARD LEVEL 1-4

600/1000VMulticore,

with jacketCU/EI 110 EPR/EM

104 EVA1-21C

0.75mm2 - 6mm2, Class 5 Stranding

EN 50264-3-2

EN 50267-2-1/2, EN50305,

EN 50305, EN 50268-2, BS6853, DIN 5510 P1,

HAZARD LEVEL 1-4

600/1000VMulticore,

with jacket fire resistant

CU/MICA/EI107 EVA 1-21C0.75mm2- 6mm2,

Class 5 StrandingEN

50264-3-1

EN 50267-2-1/2, EN50305,

EN 50305, EN 50268-2,

BS6853, DIN 5510 P1,

HAZARD LEVEL 1-4,

EN 50200 (15MIN)

1800/3000VMulticore,

with jacketCU/EI 110 EPR/EM

104 EVA2-37 C

1.5mm2-2.5mm2,

Class 5 StrandingEN

50264-3-1BS 6853A/B/II,

NF F 16 101

Page 11: Rolling Stock Cables Rolling... · RSE/STD/024 Part 6 Rolling Stock Cable..... 29. Caledonian 4 Rolling Stock Cable Caledonian 5 Rolling Stock Cable Single Core, Rubber Sheathed,

Caledonian

20

Rolling Stock CableCaledonian

21

Rolling Stock CableRubber Type

300/500V Multipairs rubber cable with jacket

Cross-sectional 0.75mm2-1mm2

Voltage rating 300-500VNumber of Pairs 1-3Conductor class IEC 60228 Class 5

Insulation EPRJacket PCP

No. of Cores/Pairs

Cross Sectional Area

(mm2)

Number and Nominal Diameter

of Strands (mm)

Voltage Rating(V)

Nominal Overall

Diameter (mm)

Nominal Weight (kg/km)

1 Pair 0.75 24/0.2 300/500 10.0 160.01 Pair 1.0 32/0.2 300/500 10.7 180.01 Pair 1.0 32/0.2 300/500 12.5 230.02 Pair 1.0 32/0.2 300/500 22.0 590.03 Pair 1.0 32/0.2 300/500 22.4 630.01 Pair 1.0 32/0.2 300/500 15.7 290.0

300/500V Multicore rubber cable with jacket

Cross-sectional 1.0mm2-4.0mm2

Voltage rating 300-500VNumber of Cores 12-42Conductor class IEC 60228 Class 5

Insulation EPRJacket PCP

No. of Cores/Pairs

Cross Sectional Area

(mm2)

Number and Nominal Diameter

of Strands (mm)

Voltage Rating(V)

Nominal Overall

Diameter (mm)

Nominal Weight (kg/km)

12 Core 1.0 32/0.25 300/500 20.3 450.019 Core 2.5 50/0.25 300/500 26.4 1200.027 Core 2.5 50/0.25 300/500 32.0 1500.036 Core 1.5 30/0.25 300/500 34.6 1600.042 Core 1.5 30/0.25 300/500 38.4 1900.010 Core 2.5 50/0.25 300/500 28.1 910.020 Core 4.0 56/0.3 300/500 42.7 2400.0

LSOH Type

300/500V Multicore LSOH rubber cable with with jacket

Cross- sectional Area 0.75mmsq-6 mmsqVoltage rating 300/500V

Conductor Flexible Stranded Tinned CopperNumber of cores 1-21Conductor class IEC 60228 Class 5

Insulation Cross linked EPR rubber type EI 110 or equivalent, in accordance with EN 50264-1

Jacket Cross linked EVA rubber type EM 104 or equivalent, in accordance with EN 50264-1

Fire Standard BS 6853-la,DIN 5510-1 1-4.NFF 16-101 FO

No. of Cores/Pairs

Cross Sectional Area

(mm2)

Number and Nominal Diameter

of Strands(mm)

Voltage Rating(V)

Nominal Overall

Diameter(mm)

Nominal Weight (kg/km)

1 Core 0.75 24/0.2 300/500 4.2 302 Core 0.75 24/0.2 300/500 7.0 653 Core 0.75 24/0.2 300/500 7.4 804 Core 0.75 24/0.2 300/500 8.0 955 Core 0.75 24/0.2 300/500 8.8 1156 Core 0.75 24/0.2 300/500 9.5 1307 Core 0.75 24/0.2 300/500 10.3 14810 Core 0.75 24/0.2 300/500 12.2 20512 Core 0.75 24/0.2 300/500 12.4 23014 Core 0.75 24/0.2 300/500 12.9 26016 Core 0.75 24/0.2 300/500 13.7 29619 Core 0.75 24/0.2 300/500 15.0 33521 Core 0.75 24/0.2 300/500 15.9 3801 Core 1 32/0.25 300/500 4.5 352 Core 1 32/0.25 300/500 7.5 753 Core 1 32/0.25 300/500 8.0 954 Core 1 32/0.25 300/500 8.6 1155 Core 1 32/0.25 300/500 9.4 1306 Core 1 32/0.25 300/500 10.4 1607 Core 1 32/0.25 300/500 11.3 18510 Core 1 32/0.25 300/500 13.3 25012 Core 1 32/0.25 300/500 13.5 28014 Core 1 32/0.25 300/500 14.0 30516 Core 1 32/0.25 300/500 14.9 35019 Core 1 32/0.25 300/500 16.9 44021 Core 1 32/0.25 300/500 17.7 4802 Core 4 32/0.25 300/500 11.5 2003 Core 4 32/0.25 300/500 12.2 2404 Core 4 32/0.25 300/500 13.7 3105 Core 4 32/0.25 300/500 15.0 3807 Core 4 32/0.25 300/500 18.2 53010 Core 4 32/0.25 300/500 22.1 76013 Core 4 32/0.25 300/500 22.1 820

Page 12: Rolling Stock Cables Rolling... · RSE/STD/024 Part 6 Rolling Stock Cable..... 29. Caledonian 4 Rolling Stock Cable Caledonian 5 Rolling Stock Cable Single Core, Rubber Sheathed,

Caledonian

22

Rolling Stock CableCaledonian

23

Rolling Stock Cable

No. of Cores/Pairs

Cross Sectional Area

(mm2)

Number and Nominal Diameter

of Strands(mm)

Voltage Rating(V)

Nominal Overall

Diameter(mm)

Nominal Weight (kg/km)

2 Core 6 32/0.25 300/500 12.9 2503 Core 6 32/0.25 300/500 13.8 3204 Core 6 32/0.25 300/500 15.4 4205 Core 6 32/0.25 300/500 17.0 5207 Core 6 32/0.25 300/500 20.7 7451 Core 1.5 32/0.25 300/500 5.0 452 Core 1.5 32/0.25 300/500 8.7 1053 Core 1.5 32/0.25 300/500 9.3 1254 Core 1.5 32/0.25 300/500 10.3 1605 Core 1.5 32/0.25 300/500 11.1 1906 Core 1.5 32/0.25 300/500 12.2 2307 Core 1.5 32/0.25 300/500 13.2 26010 Core 1.5 32/0.25 300/500 16.0 35012 Core 1.5 32/0.25 300/500 16.2 37514 Core 1.5 32/0.25 300/500 17.2 45016 Core 1.5 32/0.25 300/500 18.0 51019 Core 1.5 32/0.25 300/500 20.3 63021 Core 1.5 32/0.25 300/500 21.3 7002 Core 2.5 32/0.25 300/500 10.3 1503 Core 2.5 32/0.25 300/500 10.9 1804 Core 2.5 32/0.25 300/500 11.9 2205 Core 2.5 32/0.25 300/500 13.3 2707 Core 2.5 32/0.25 300/500 16.1 40010 Core 2.5 32/0.25 300/500 19.2 54012 Core 2.5 32/0.25 300/500 19.2 57014 Core 2.5 32/0.25 300/500 20.5 68016 Core 2.5 32/0.25 300/500 21.9 77019 Core 2.5 32/0.25 300/500 24.4 95021 Core 2.5 32/0.25 300/500 25.6 1040

600/1000V Multicore LSOH rubber cable with with jacket

Cross-sectional Area 0.75mm2-6mm2

Voltage rating 600/1000VConductor Flexible Stranded Tinned Copper

Number of cores 1-21Conductor class IEC 60228 Class 5

Insulation Cross linked EPR rubber type EI 110 or equivalent, in accordance with EN 50264-1Jacket Cross linked EVA rubber type EI 104 or equivalent, in accordance with EN 50264-1

Fire Standard BS 6853-la,DIN 5510-1 1-4.NFF 16-101 FO

No. of Cores/Pairs

Cross Sectional Area

(mm2)

Number and Nominal Diameter of Strands (mm)

Voltage Rating(V)

Nominal Overall

Diameter(mm)

Nominal Weight (kg/km)

1 Core 0.75 24/0.2 600/1000 4.2 302 Core 0.75 24/0.2 600/1000 7.0 653 Core 0.75 24/0.2 600/1000 7.4 804 Core 0.75 24/0.2 600/1000 8.0 955 Core 0.75 24/0.2 600/1000 8.8 1156 Core 0.75 24/0.2 600/1000 9.5 1307 Core 0.75 24/0.2 600/1000 10.3 148

10 Core 0.75 24/0.2 600/1000 12.2 20512 Core 0.75 24/0.2 600/1000 12.4 23014 Core 0.75 24/0.2 600/1000 12.9 26016 Core 0.75 24/0.2 600/1000 13.7 29619 Core 0.75 24/0.2 600/1000 15.0 33521 Core 0.75 24/0.2 600/1000 15.9 3801 Core 1 32/0.2 600/1000 4.5 352 Core 1 32/0.2 600/1000 7.5 753 Core 1 32/0.2 600/1000 8.0 954 Core 1 32/0.2 600/1000 8.6 1155 Core 1 32/0.2 600/1000 9.4 1306 Core 1 32/0.2 600/1000 10.4 1607 Core 1 32/0.2 600/1000 11.3 18510 Core 1 32/0.2 600/1000 13.3 25012 Core 1 32/0.2 600/1000 13.5 28014 Core 1 32/0.2 600/1000 14.0 30516 Core 1 32/0.2 600/1000 14.9 35019 Core 1 32/0.2 600/1000 16.9 44021 Core 1 32/0.2 600/1000 17.7 4802 Core 4 32/0.25 600/1000 11.5 2003 Core 4 32/0.25 600/1000 12.2 2404 Core 4 32/0.25 600/1000 13.7 3105 Core 4 32/0.25 600/1000 15.0 3807 Core 4 32/0.25 600/1000 18.2 53010 Core 4 32/0.25 600/1000 22.1 76013 Core 4 32/0.25 600/1000 22.1 8202 Core 6 32/0.25 600/1000 12.9 2503 Core 6 32/0.25 600/1000 13.8 3204 Core 6 32/0.25 600/1000 15.4 4205 Core 6 32/0.25 600/1000 17.0 5207 Core 6 32/0.25 600/1000 20.7 7451 Core 1.5 32/0.25 600/1000 5.0 452 Core 1.5 32/0.25 600/1000 8.7 1053 Core 1.5 32/0.25 600/1000 9.3 1254 Core 1.5 32/0.25 600/1000 10.3 1605 Core 1.5 32/0.25 600/1000 11.1 1906 Core 1.5 32/0.25 600/1000 12.2 2307 Core 1.5 32/0.25 600/1000 13.2 26010 Core 1.5 32/0.25 600/1000 16.0 35012 Core 1.5 32/0.25 600/1000 16.2 37514 Core 1.5 32/0.25 600/1000 17.2 45016 Core 1.5 32/0.25 600/1000 18.0 51019 Core 1.5 32/0.25 600/1000 20.3 63021 Core 1.5 32/0.25 600/1000 21.3 700

Page 13: Rolling Stock Cables Rolling... · RSE/STD/024 Part 6 Rolling Stock Cable..... 29. Caledonian 4 Rolling Stock Cable Caledonian 5 Rolling Stock Cable Single Core, Rubber Sheathed,

Caledonian

24

Rolling Stock CableCaledonian

25

Rolling Stock Cable

No. of Cores/Pairs

Cross Sectional Area

(mm2)

Number and Nominal Diameter of Strands (mm)

Voltage Rating(V)

Nominal Overall

Diameter(mm)

Nominal Weight (kg/km)

2 Core 2.5 32/0.25 600/1000 10.3 1503 Core 2.5 32/0.25 600/1000 10.9 1804 Core 2.5 32/0.25 600/1000 11.9 2205 Core 2.5 32/0.25 600/1000 13.3 2707 Core 2.5 32/0.25 600/1000 16.1 40010 Core 2.5 32/0.25 600/1000 19.2 54012 Core 2.5 32/0.25 600/1000 19.2 57014 Core 2.5 32/0.25 600/1000 20.5 68016 Core 2.5 32/0.25 600/1000 21.9 77019 Core 2.5 32/0.25 600/1000 24.4 95021 Core 2.5 32/0.25 600/1000 25.6 1040

600/1000V Multicore LSOH fire resistant rubber cable with with jacket

Cross-sectional Area 0.75mm2-6 mm2

Voltage rating 600/1000VConductor Flexible Stranded Tinned Copper

Number of cores 1-21Conductor class IEC 60228 Class 5

Insulation Cross linked EPR rubber type EI 110 or equivalent, in accordance with EN 50264-1Flame Barrier Mice Glass Tape

Jacket Cross linked EVA rubber type EM 104 or equivalent, in accordance with EN 50264-1

Fire Standard BS 6853-la,DIN 5510-1 1-4.NF F 16-101 FO

No. of CoresCross

Sectional Area(mm2)

Number and Nominal Diameter

of Strands(mm)

Voltage Rating

(V)

Nominal Overall

Diameter (mm)

Nominal Weight (kg/km)

1 Core 0.75 24/0.2 600/1000 4.2 302 Core 0.75 24/0.2 600/1000 7.0 653 Core 0.75 24/0.2 600/1000 7.4 804 Core 0.75 24/0.2 600/1000 8.0 955 Core 0.75 24/0.2 600/1000 8.8 1156 Core 0.75 24/0.2 600/1000 9.5 1307 Core 0.75 24/0.2 600/1000 10.3 148

10 Core 0.75 24/0.2 600/1000 12.2 20512 Core 0.75 24/0.2 600/1000 12.4 23014 Core 0.75 24/0.2 600/1000 12.9 26016 Core 0.75 24/0.2 600/1000 13.7 29619 Core 0.75 24/0.2 600/1000 15.0 33521 Core 0.75 24/0.2 600/1000 15.9 3801 Core 1 32/0.25 600/1000 4.5 352 Core 1 32/0.25 600/1000 7.5 753 Core 1 32/0.25 600/1000 8.0 954 Core 1 32/0.25 600/1000 8.6 1155 Core 1 32/0.25 600/1000 9.4 130

No. of CoresCross

Sectional Area(mm2)

Number and Nominal Diameter

of Strands(mm)

Voltage Rating

(V)

Nominal Overall

Diameter (mm)

Nominal Weight (kg/km)

6 Core 1 32/0.25 600/1000 10.4 1607 Core 1 32/0.25 600/1000 11.3 18510 Core 1 32/0.25 600/1000 13.3 25012 Core 1 32/0.25 600/1000 13.5 28014 Core 1 32/0.25 600/1000 14.0 30516 Core 1 32/0.25 600/1000 14.9 35019 Core 1 32/0.25 600/1000 16.9 44021 Core 1 32/0.25 600/1000 17.7 4802 Core 4 32/0.25 600/1000 11.5 2003 Core 4 32/0.25 600/1000 12.2 2404 Core 4 32/0.25 600/1000 13.7 3105 Core 4 32/0.25 600/1000 15.0 3807 Core 4 32/0.25 600/1000 18.2 53010 Core 4 32/0.25 600/1000 22.1 76013 Core 4 32/0.25 600/1000 22.1 8202 Core 6 32/0.25 600/1000 12.9 2503 Core 6 32/0.25 600/1000 13.8 3204 Core 6 32/0.25 600/1000 15.4 4205 Core 6 32/0.25 600/1000 17.0 5207 Core 6 32/0.25 600/1000 20.7 7451 Core 1.5 32/0.25 600/1000 5.0 452 Core 1.5 32/0.25 600/1000 8.7 1053 Core 1.5 32/0.25 600/1000 9.3 1254 Core 1.5 32/0.25 600/1000 10.3 1605 Core 1.5 32/0.25 600/1000 11.1 1906 Core 1.5 32/0.25 600/1000 12.2 2307 Core 1.5 32/0.25 600/1000 13.2 26010 Core 1.5 32/0.25 600/1000 16.0 35012 Core 1.5 32/0.25 600/1000 16.2 37514 Core 1.5 32/0.25 600/1000 17.2 45016 Core 1.5 32/0.25 600/1000 18.0 51019 Core 1.5 32/0.25 600/1000 20.3 63021 Core 1.5 32/0.25 600/1000 21.3 7002 Core 2.5 32/0.25 600/1000 10.3 1503 Core 2.5 32/0.25 600/1000 10.9 1804 Core 2.5 32/0.25 600/1000 11.9 2205 Core 2.5 32/0.25 600/1000 13.3 2707 Core 2.5 32/0.25 600/1000 16.1 40010 Core 2.5 32/0.25 600/1000 19.2 54012 Core 2.5 32/0.25 600/1000 19.2 57014 Core 2.5 32/0.25 600/1000 20.5 68016 Core 2.5 32/0.25 600/1000 21.9 77019 Core 2.5 32/0.25 600/1000 24.4 95021 Core 2.5 32/0.25 600/1000 25.6 1040

Page 14: Rolling Stock Cables Rolling... · RSE/STD/024 Part 6 Rolling Stock Cable..... 29. Caledonian 4 Rolling Stock Cable Caledonian 5 Rolling Stock Cable Single Core, Rubber Sheathed,

Caledonian

26

Rolling Stock CableCaledonian

27

Rolling Stock Cable

1800/3000V Multicore LSOH rubber cable with jacket

Cross- sectional Area 1.5mmsq-2.5 mmsq

Voltage rating 1800/3000VConductor Flexible Stranded Tinned Copper

Number of cores 2-37Conductor class IEC 60228 Class 5

Insulation Cross linked EPR rubber type EI 110 or equivalent, in accordance with EN 50264-1Jacket Cross linked EVA rubber type EM 104 or equivalent, in accordance with EN 50264-1

Fire Standard BS 6853-la,DIN 5510-1 1-4.NF F 16-101 FO

No. of Cores

Cross Sectional

Area(mm2)

Number and Nominal Diameter

of Strands

Voltage Rating(V)

Nominal Overall

Diameter (mm)

Nominal Weight (kg/km)

2 Core 1.5 30/0.25 1800/3000 10.9 1573 Core 1.5 30/0.25 1800/3000 11.6 1754 Core 1.5 30/0.25 1800/3000 12.6 2075 Core 1.5 30/0.25 1800/3000 13.6 2167 Core 1.5 30/0.25 1800/3000 14.5 27213 Core 1.5 30/0.25 1800/3000 19.0 44119 Core 1.5 30/0.25 1800/3000 21.3 51528 Core 1.5 30/0.25 1800/3000 25.6 94137 Core 1.5 30/0.25 1800/3000 28.6 13652 Core 2.5 50/0.25 1800/3000 12.3 1953 Core 2.5 50/0.25 1800/3000 13.1 2414 Core 2.5 50/0.25 1800/3000 14.3 2815 Core 2.5 50/0.25 1800/3000 15.4 3127 Core 2.5 50/0.25 1800/3000 16.6 37513 Core 2.5 50/0.25 1800/3000 22.0 64619 Core 2.5 50/0.25 1800/3000 24.8 83527 Core 2.5 50/0.25 1800/3000 30.2 127637 Core 2.5 50/0.25 1800/3000 33.2 1680

Databus, RS 485 Cable

Voltage Cable Type ConstructionNumberof Cores

Cross Sectional

Areas/Stranding

Class

Design Standard Fire

300/500VMultipair,

with jacket screened

CU/XL FOAM PE/ALTO/CUTO/

EM 104 EVA1-4 Pr

0.22-1mm2

Class 5 strandingEN 50264, DIN 5510

IEC 332-3C IEC 754 IEC1034

300/500VMultipair,

with jacket screened

CU/XL FOAM PE/CUTO/EM

104 EVA1-4 Pr

0.22-1mm2

Class 5 strandingEN 50264, DIN 5510

BS 6853 NF F

16-101 FO

300/500V Multipair Databus RS 485 Double screened Cable

Cross-sectional Area 0.22mm2-1mm2

Voltage rating 300/500VConductor Flexible Stranded Tinned Copper

Number of pair 1-4Conductor class IEC 60228 Class 5

Insulation Cross linked Foam PEScreen Individual Aluminium Tape+Overall Copper Wire Braid

Jacket Cross linked EVA rubber type EM 104 or equivalent, in accordance with EN 50264-1

Fire Standard IEC 332-3C IEC 754 IEC1034

Electrical Characteristic Impedance 120 ohm ±15%

Capacitance 41nF/Km@1KHzInsulation Resistance 5000 M ohm

No.of PairsCross

Sectional Area(mm2)

Number and Nominal Diameter of

Strands(mm)

Voltage Rating

(V)

Nominal Overall

Diameter (mm)

Nominal Weight (kg/km)

1 0.22 7/0.2 300/500 4.5 582 0.22 7/0.2 300/500 6.2 794 0.22 7/0.2 300/500 6.5 1181 0.5 16/0.2 300/500 6.6 792 0.5 16/0.2 300/500 9.0 1054 0.5 16/0.2 300/500 9.8 1451 0.75 24/0.2 300/500 9.5 1152 0.75 24/0.2 300/500 10.3 1354 0.75 24/0.2 300/500 11.6 1821 1 30/0.2 300/500 11.5 1252 1 30/0.2 300/500 12.5 1504 1 30/0.2 300/500 13.5 180

Page 15: Rolling Stock Cables Rolling... · RSE/STD/024 Part 6 Rolling Stock Cable..... 29. Caledonian 4 Rolling Stock Cable Caledonian 5 Rolling Stock Cable Single Core, Rubber Sheathed,

Caledonian

28

Rolling Stock CableCaledonian

29

Rolling Stock Cable

300/500V Multipair Databus RS 485 Single screened Cable

Cross- sectional Area 0.22mm2-1mm2

Voltage rating 300/500VConductor Flexible Stranded Tinned Copper

Number of pair 1-4Conductor class IEC 60228 Class 5

Insulation Cross linked Foam PEScreen Copper Wire Braid

Jacket Cross linked EVA rubber type EM 104 or equivalent, in accordance with EN 50264-1

Fire Standard BS 6853 Category la,lb and 11 and NF F 16-101 FO

Electrical Characteristic Impedance 120 ohm ±15%

Capacitance 41nF/Km@1KHzInsulation Resistance 5000 M ohm

No. of PairsCross

Sectional Area(mm2)

Number and Nominal Diameter of

Strands(mm)

Voltage Rating

(V)

Nominal Overall

Diameter (mm)

Nominal Weight (kg/km)

1 0.22 7/0.2 300/500 4.2 552 0.22 7/0.2 300/500 5.9 754 0.22 7/0.2 300/500 6.2 1151 0.5 16/0.2 300/500 6.3 752 0.5 16/0.2 300/500 8.5 1004 0.5 16/0.2 300/500 9.4 1401 0.75 24/0.2 300/500 9.0 1102 0.75 24/0.2 300/500 9.7 1304 0.75 24/0.2 300/500 11.1 1781 1 30/0.2 300/500 11.0 1202 1 30/0.2 300/500 12.0 1454 1 30/0.2 300/500 13.0 175

RSE/STD/024 Part 6 Rolling Stock Cable

Voltage Cable Type ConstructionNumber

of Cores

Cross Sectional Areas/Stranding

Class

Design Standard Fire Standard

300/500VSingle Core,

unsheathedCU/EM 104 EVA 1C 0.5mm2-4mm2,

19/37 strandingRSE/STD/024

Part 6IEC 332-3C

IEC 754 IEC1034

300/500VSingle Core,

unsheathedCU/EM 104 EVA 1C 0.5mm2-10mm2,

Class 5 strandingRSE/STD/024

Part 6IEC 332-3C

IEC 754 IEC1034

300/500VSingle Core,

unsheathedCU/EM 104 EVA 1C 1.0mm2-6.0mm2,

Class 5 strandingRSE/STD/024

Part 6IEC 332-3C

IEC 754 IEC1034

300/500VMulticore, with jacket

Type ⅦCU/EI 104 EPR/

EM 104 EVA 12/42C 1.0mm2-1.5mm2, Class 5 stranding

RSE/STD/024 Part 6

IEC 332-3CIEC 754 IEC1034

300/500VMulticore, with jacket

Type Ⅶ

CU/EI 104 EPR/EM 104 EVA 12/42C 1.0mm2-1.5mm2,

Class 5 strandingRSE/STD/024

Part 6IEC 332-3C

IEC 754 IEC1034

300/500VMultipair,

with jacket screened

CU/EI 104 EPR/CUTO/EM 104

EVA1,2,3 Prs

0.5mm2-1.0mm2, Class 5 stranding

RSE/STD/024 Part 6

IEC 332-3CIEC 754 IEC1034

300/500VMultipair,

with jacket screened

CU/EI 104 EPR/CUTO/EM 104

EVA1,2,3,4

Prs0.5mm2-1.0mm2, Class 5 stranding

RSE/STD/024 Part 6

IEC 332-3CIEC 754 IEC1034

600/1000VSingle Core,

unsheathedCU/EM 104 EVA 1C 0.5mm2-4mm2,

19/37 strandRSE/STD/024

Part 6IEC 332-3C

IEC 754 IEC1034

600/1000VSingle Core,

unsheathedCU/EM 104 EVA 1C 0.75mm2-300mm2,

Class 5 strandingRSE/STD/024

Part 6IEC 332-3C

IEC 754 IEC1034

600/1000VSingle Core,

unsheathedCU/EM 104 EVA 1C 50mm2-185mm2,

Class 5 strandingRSE/STD/024

Part 6IEC 332-3C

IEC 754 IEC1034

600/1000V Multicore, with jacket

CU/EI 104 EPR/EM 104 EVA 10/20C 2.5mm2-4mm2,

Class 5 strandingRSE/STD/024

Part 6IEC 332-3C

IEC 754 IEC1034

600/1000VSinglepair, with jacket screened

CU/EI 104 EPR/CUTO/EM 104

EVA1 Prs 1.0mm2, Class 5

strandingRSE/STD/024

Part 6IEC 332-3C

IEC 754 IEC1034

300/500V Singlecore RSE/STD/024 Part 6 Rolling StockType Ⅶ Cable, unsheathed

Cross- sectional Area 0.5mm2-4mm2

Voltage rating 300/500VConductor Flexible Stranded Tinned Copper

Number of cores 1Conductor class 19/37 AWG stranding

Insulation Cross linked EPR rubber type EI 107, Reduced WallFire standard IEC 332-3C,IEC754;IEC1034-1/2

Page 16: Rolling Stock Cables Rolling... · RSE/STD/024 Part 6 Rolling Stock Cable..... 29. Caledonian 4 Rolling Stock Cable Caledonian 5 Rolling Stock Cable Single Core, Rubber Sheathed,

Caledonian

30

Rolling Stock CableCaledonian

31

Rolling Stock Cable

No. of CoresCross

Sectional Area(mm2)

Number and Nominal Diameter of

Strands(mm)

Voltage Rating

(V)

Nominal Overall

Diameter (mm)

Nominal Weight (kg/km)

singlecore 0.5 19/0.18 300/500 1.34 5.4singlecore 0.75 37/0.16 300/500 1.56 8.0singlecore 1.0 37/0.18 300/500 1.69 9.9singlecore 1.5 37/0.23 300/500 2.07 15.7singlecore 2.5 37/0.3 300/500 2.66 26.8singlecore 4.0 37/0.37 300/500 3.32 41.1

300/500V Singlecore RSE/STD/024 Part 6 Rolling Stock Type Cable, unsheathed

Cross- sectional Area 0.5mm2-10mm2

Voltage rating 300/500VConductor Flexible Stranded Tinned Copper

Number of cores 1Conductor class IEC 60228 Class 5

Insulation Cross linked EPR rubber type EI 107, Standard WallFire standard IEC 332-3C,IEC754;IEC1034-1/2

No. of CoresCross

Sectional Area(mm2)

Number and Nominal Diameter of

Strands(mm)

Voltage Rating

(V)

Nominal Overall

Diameter(mm)

Nominal Weight (kg/km)

singlecore 0.5 16/0.2 300/500 2.32 9.6singlecore 0.75 74/0.2 300/500 2.53 12.4singlecore 1.0 32/0.2 300/500 2.71 15.1singlecore 1.5 30/0.25 300/500 3.23 21.9singlecore 2.5 50/0.25 300/500 3.7 33.5singlecore 4.0 56/0.3 300/500 4.5 50.0singlecore 6.0 84/0.3 300/500 5.09 74.6singlecore 10.0 80/0.4 300/500 6.3 122.6

300/500V Single Core RSE/STD/024 Part 6 Rolling Stock Type screened Cable

Cross- sectional Area 1.0mm2-6.0mm2

Voltage rating 300/500VConductor Flexible Stranded Tinned CopperNumber of cores 1Conductor class IEC 60228 Class 5Insulation Cross linked EPR rubber type EI 107, Standard WallFire standard IEC 332-3C,IEC754;IEC1034-1/2

No. of CoresCross

Sectional Area(mm2)

Number and Nominal Diameter of

Strands(mm)

Voltage Rating

(V)

Nominal Overall

Diameter (mm)

Nominal Weight (kg/km)

Singlecore 1.0 32/0.2 300/500 3.3 19.2Singlecore 1.5 30/0.25 300/500 3.7 26.3Singlecore 2.5 50/0.25 300/500 4.16 37.8Singlecore 4.0 56/0.3 300/500 4.95 56.6Singlecore 6.0 84/0.3 300/500 5.55 80.4

300/500V Multicore RSE/STD/024 Part 6 Rolling Stock Type Cable, with jacket

Cross- sectional Area 1.0mm2-1.5mm2

Voltage rating 300/500VConductor Flexible Stranded Tinned Copper

Number of cores 12-42Conductor class IEC 60228 Class 5

Insulation Cross linked EPR rubber type EI 107, Standard WallJacket Cross linked EVA rubber type EM 104

Fire standard IEC 332-3C,IEC754;IEC1034-1/2

No. of CoresCross

Sectional Area(mm2)

Number and Nominal Diameter of

Strands(mm)

Voltage Rating

(V)

Nominal Overall

Diameter (mm)

Nominal Weight(kg/km)

12 Core 1.0 32/0.2 30/50 20.25 309.042 Core 1.5 30/0.25 30/50 38.35 1661.0

300/500V Multicore RSE/STD/024 Part 6 Rolling Stock Type Cable, with jacket

Cross- sectional Area 1.0mm2-1.5mm2

Voltage rating 300/500VConductor Flexible Stranded Tinned Copper

Number of cores 12-42Conductor class IEC 60228 Class 5

Insulation Cross linked EPR rubber type EI 107,Standard WallJacket Cross linked EVA rubber type EMI 104

Fire standard IEC 332-3C,IEC754;IEC1034-1/2

No. of CoresCross

Sectional Area(mm2)

Number and Nominal Diameter of

Strands(mm)

Voltage Rating

(V)

Nominal Overall

Diameter (mm)

Nominal Weight(kg/km)

12 Core 1.0 32/0.2 300/500 20.3 309.042 Core 1.5 30/0.25 300/500 38.4 1661.0

Page 17: Rolling Stock Cables Rolling... · RSE/STD/024 Part 6 Rolling Stock Cable..... 29. Caledonian 4 Rolling Stock Cable Caledonian 5 Rolling Stock Cable Single Core, Rubber Sheathed,

Caledonian

32

Rolling Stock CableCaledonian

33

Rolling Stock Cable300/500V Multipair RSE/STD/024 Part 6 Rolling Stock Type screened Cable, with jacket

Cross- sectional Area 0.5mm2-1.0mm2

Voltage rating 30/50VConductor Flexible Stranded Tinned Copper

Number of pairs 1,2,3Conductor class IEC 60228 Class 5

Screen Copper Braid ScreenInsulation Cross linked EPR rubber type EI 107, Standard wale

Jacket Cross linked EVA rubber type EM 104Fire standard IEC 332-3C,IEC754;IEC1034-1/2

No. of PairsCross

Sectional Area(mm2)

Number and Nominal Diameter of

Strands(mm)

Voltage Rating

(V)

Nominal Overall

Diameter(mm)

Nominal Weight(kg/km)

1 Pair 0.5 16/0.2 30/50 8.45 99.01 Pair 0.75 24/0.2 30/50 9.2 110.01 Pair 1.0 32/0.2 30/50 9.5 139.01 Pair 1.0 32/0.2 30/50 11.7 186.01 Pair 1.0 32/0.2 30/50 15.6 306.02 Pair 1.0 32/0.2 30/50 15.7 443.03 Pair 1.0 32/0.2 30/50 21.7 662.0

300/500V Multipair RSE/STD/024 Part 6 Rolling StockType screened Cable, with jacket

Cross- sectional Area 0.5mm2-1.0mm2

Voltage rating 300/500VConductor Flexible Stranded Tinned Copper

Number of pairs 1,2,3,4Conductor class 19/37 AWG Stranding

Insulation Cross linked EPR rubber type EI 107, Reduced WallScreen Copper Braid ScreenJacket Cross linked EVA rubber type EM 104

Fire standard IEC 332-3C,IEC754;IEC1034-1/2

No. of PairsCross

Sectional Area(mm2)

Number and Nominal Diameter of

Strands(mm)

Voltage Rating

(V)

Nominal Overall

Diameter (mm)

Nominal Weight (kg/km)

1 Pair 0.5 19/0.18 30/50 6.1 57.02 Pair 0.5 19/0.18 30/50 10.2 110.01 Pair 1.0 37/0.18 30/50 7.0 85.02 Pair 1.0 37/0.18 30/50 12.2 187.53 Pair 1.0 37/0.18 30/50 12.9 217.04 Pair 1.0 37/0.18 30/50 14.0 290.0

600/1000V Singlecore RSE/STD/024 Part 6 Rolling Stock TypeCable, unsheathed

Cross-sectional Area 0.5mm2-4mm2

Voltage rating 600/1000VConductor Flexible Stranded Tinned Copper

Number of cores 1Conductor class 19/37 AWG Stranding

Insulation Cross linked EPR rubber type EI 107 Reduced wallFire standard IEC 332-3C,IEC754;IEC1034-1/2

No. of CoresCross

Sectional Area(mm2)

Number and Nominal Diameter of

Strands(mm)

Voltage Rating

(V)

Nominal Overall

Diameter (mm)

Nominal Weight (kg/km)

singlecore 0.5 19/0.18 600/1000 1.5 5.9singlecore 0.75 37/0.16 600/1000 1.76 8.7singlecore 1.0 37/0.18 600/1000 1.9 10.7singlecore 1.5 37/0.23 600/1000 2.25 16.5singlecore 2.5 37/0.3 600/1000 2.84 28.0singlecore 4.0 37/0.37 600/1000 3.44 42.0

600/1000V Singlecore RSE/STD/024 Part 6 Rolling StockType Cable, unsheathed

Cross- sectional Area 0.75mm2-300mm2

Voltage rating 600/1000VConductor Flexible Stranded Tinned Copper

Number of cores 1Conductor class IEC 60228 Class 5

Insulation Cross linked EPR rubber type EI 107, Standard WallFire standard IEC 332-3C,IEC754;IEC1034-1/2

Page 18: Rolling Stock Cables Rolling... · RSE/STD/024 Part 6 Rolling Stock Cable..... 29. Caledonian 4 Rolling Stock Cable Caledonian 5 Rolling Stock Cable Single Core, Rubber Sheathed,

Caledonian

34

Rolling Stock CableCaledonian

35

Rolling Stock Cable

No. of Cores/Pairs

Cross Sectional Area

(mm2)

Number and Nominal Diameter of

Strands(mm)

Voltage Rating

(V)

Nominal Overall

Diameter (mm)

Nominal Weight (kg/km)

singlecore 0.75 24/0.2 600/1000 2.99 14.9singlecore 1.0 32/0.2 600/1000 3.3 19.2singlecore 1.5 30/0.25 600/1000 3.69 26.3singlecore 2.5 50/0.25 600/1000 4.16 37.8singlecore 4.0 56/0.3 600/1000 4.95 56.6singlecore 6.0 84/0.3 600/1000 5.55 80.4singlecore 10.0 80/0.4 600/1000 7.0 135.0singlecore 16.0 128.4 600/1000 8.35 201.8singlecore 25.0 196/0.4 600/1000 10.2 3.9.3singlecore 35.0 2/6/0.4 600/1000 11.75 404.1singlecore 50.0 396/0.4 600/1000 13.7 562.0singlecore 70.0 360/0.5 600/1000 16.25 768.0singlecore 95.0 476/0.6 600/1000 18.05 1002.8singlecore 150.0 756/0.5 600/1000 22.95 1583.0singlecore 240.0 1221/0.5 600/1000 27.9 2516.0singlecore 300.0 1525/0.5 600/1000 31.35 3089.0

600/1000V Singlecore RSE/STD/024 Part 6 Rolling StockType Cable ,unsheathed

Cross- sectional Area 50mm2-185mm2

Voltage rating 600/1000VConductor Flexible Stranded Tinned Copper

Number of cores 1Conductor class IEC 60228 Class 5

Insulation Cross linked EPR rubber type EI 107, Enhanced WallFire standard IEC 332-3C,IEC754;IEC1034-1/2

No. of CoresCross

Sectional Area(mm2)

Number and Nominal Diameter of

Strands(mm)

Voltage Rating

(V)

Nominal Overall

Diameter (mm)

Nominal Weight (kg/

km)

singlecore 50.0 396/0.4 600/1000 16.45 667.0singlecore 70.0 360/0.5 600/1000 18.35 873.0singlecore 95.0 475/0.6 600/1000 19.5 1108.0singlecore 150.0 756/0.5 600/1000 24.1 1663.0singlecore 185.0 925/0.5 600/1000 26.5 2024.0

600/1000V Multicore RSE/STD/024 Part 6 Rolling Stock Type Cable, with jacket

Cross- sectional Area 2.5mm2-4mm2

Voltage rating 600/1000VConductor Flexible Stranded Tinned Copper

Number of cores 10-20Conductor class IEC 60228 Class 5

Insulation Cross linked EPR rubber type EI 107, Standard WallJacket Cross linked EVA rubber type EM 104

Fire standard IEC 332-3C,IEC754;IEC1034-1/2

No. of CoresCross

Sectional Area(mm2)

Number and Nominal Diameter of

Strands(mm)

Voltage Rating

(V)

Nominal Overall

Diameter (mm)

Nominal Weight (kg/km)

10 Core 2.5 50/0.25 600/1000 28.1 1148.020 Core 4.0 56/0.3 600/1000 42.7 2421.0

600/1000V Singlepair RSE/STD/024 Part 6 Rolling Stock Type screened Cable, with jacket

Cross- sectional Area 1.0mm2

Voltage rating 600/1000VConductor Flexible Stranded Tinned Copper

Number of cores 1Conductor class 37 AWG stranding

Insulation Cross linked EPR rubber type EI 107, Reduced WallScreen Copper Braid ScreenJacket Cross linked EVA rubber type EM 104

Fire standard IEC 332-3C,IEC754;IEC1034-1/2

No. of PairsCross

Sectional Area(mm2)

Number and Nominal Diameter of

Strands(mm)

Voltage Rating

(V)

Nominal Overall

Diameter (mm)

Nominal Weight (kg/

km)

1 Pair 1.0 37/0.18 600/1000 7.3 76.4

Page 19: Rolling Stock Cables Rolling... · RSE/STD/024 Part 6 Rolling Stock Cable..... 29. Caledonian 4 Rolling Stock Cable Caledonian 5 Rolling Stock Cable Single Core, Rubber Sheathed,

Caledonian

36

Rolling Stock Cable

[email protected]

[email protected]

UNITED KINGDOMPhoenix Place,North Street, Lewes, East Sussex.England, U.K. BN7 2QJ.Te l : (44) 207-4195087Fax: (44) 207-8319489