2
Rockwell MANUFACTURING COMPANY The Rockwell Building Pittsburgh, Pa. PM- .408-01-655-5010 DATED 1M 6.25·65 24-902 UNIVISE INTRODUCTION Acaref~Y study of the-~Cat.~Nd:-· 24:9-0TUfii\irse--"-~:··I~ (0"",,ilh"ij,,~""4~"'; will reveal that with a certain amount of ingenuity, it can undoubtedly be adapted to other types of machines, such as Drill Presses, Mills, etc., for other applications or purposes. . Y The following. instructions will give you an ex- planation of the setting up procedure when using the 24-902 Univise. This manual plus the Rockwell instruction manuals covering the Rockwell/Delta Toolmaker Grinder (PM 408-01-651-5003) and the Rockwell 24-823 Coolant Attachment (PM 408-01-655-5007) will be sufficient for use with the Toolmaker Chip Breaker Grinding Machine. It is of the utmost importance, therefore, that you review these manuals so that you may become thoroughly familiar with the adjustments and func- tions of its various components. OPERATION This univise is made up of Station #1 with clamp body, Stations 2 and 3, and Station 4 (base). Each station is provided with an adjustable wit- ness plate and a calibrated indexing body. The purpose of the calibrated indexing body is to keep a permanent record on tools previously ground. The tool can then be reground the same way at a later date by setting the respective stations to the proper angles which are kept on file. The base is provided with two 7/16" removable keys which fit into the T-slot of the Toolmaker grinding table. The sides of the base are also milled parallel with the key slot in the base. The reason for this is to permit the Univise to be placed against the side stop of a magnetic chuck. This will automatically bring the vise parallel with the T-slot of the table providing the magnetic chuck has been properly doweled or otherwise squared up with the table slots. Fig. 1. It should be noted that all three of the calibrated indexing bodies are identical, enabling the operator to remove one or two of the stations and mount the clamp body on the n ext one. The clamp body can also be mounted directly on the base, if necessary, for certain work. The removable keys enable the operator to use the vise on magnetic chucks and also enable the operator to make special keys when the vise is to be used on other grinders or ma- chines. The Univise has been carefully assembled at the factory and thoroughly checked for accuracy. It is. therefore not necessary to readjust the vise unless the squareness has been thrown out of adjustment in transit. If a station should be out of line, correction can be made quickly by squaring up the number and reset- ting the adjustable zero plate until it coincides with the zero or 90 degree mark of the dial.

Rockwell Univise

Embed Size (px)

DESCRIPTION

Universal vise manual

Citation preview

Page 1: Rockwell Univise

RockwellMANUFACTURING COMPANY

The Rockwell Building Pittsburgh, Pa.

PM- .408-01-655-5010

DATED 1M 6.25·65

24-902 UNIVISE

INTRODUCTION

Acaref~Y study of the-~Cat.~Nd:-· 24:9-0TUfii\irse--"-~:··I~(0"",,ilh"ij,,~""4~"';

will reveal that with a certain amount of ingenuity,it can undoubtedly be adapted to other types ofmachines, such as Drill Presses, Mills, etc., forother applications or purposes. . Y

The following. instructions will give you an ex-planation of the setting up procedure when usingthe 24-902 Univise.

This manual plus the Rockwell instruction manualscovering the Rockwell/Delta Toolmaker Grinder(PM 408-01-651-5003) and the Rockwell 24-823Coolant Attachment (PM 408-01-655-5007) will besufficient for use with the Toolmaker Chip BreakerGrinding Machine.

It is of the utmost importance, therefore, that youreview these manuals so that you may becomethoroughly familiar with the adjustments and func-tions of its various components.

OPERATION

This univise is made up of Station #1 with clampbody, Stations 2 and 3, and Station 4 (base).

Each station is provided with an adjustable wit-ness plate and a calibrated indexing body. Thepurpose of the calibrated indexing body is to keepa permanent record on tools previously ground.The tool can then be reground the same way at alater date by setting the respective stations to theproper angles which are kept on file.

The base is provided with two 7/16" removablekeys which fit into the T-slot of the Toolmakergrinding table.

The sides of the base are also milled parallel withthe key slot in the base. The reason for this isto permit the Univise to be placed against the sidestop of a magnetic chuck. This will automaticallybring the vise parallel with the T-slot of the tableproviding the magnetic chuck has been properlydoweled or otherwise squared up with the tableslots.

Fig. 1.

It should be noted that all three of the calibratedindexing bodies are identical, enabling the operatorto remove one or two of the stations and mount theclamp body on the n ext one. The clamp body canalso be mounted directly on the base, if necessary,for certain work. The removable keys enable theoperator to use the vise on magnetic chucks andalso enable the operator to make special keys whenthe vise is to be used on other grinders or ma-chines.

The Univise has been carefully assembled at thefactory and thoroughly checked for accuracy.It is. therefore not necessary to readjust the viseunless the squareness has been thrown out ofadjustment in transit.

If a station should be out of line, correction can bemade quickly by squaring up the number and reset-ting the adjustable zero plate until it coincides withthe zero or 90 degree mark of the dial.

Page 2: Rockwell Univise

; .STATION No.3

15(2)~k14(2)~/~

13/ ,

6

7

8

STATION No.2",

,~27

~ .i->': 2 8

~ .i.->: 29

,

.•.

_.;:c~....~_~;-,,---:---,-- __~~"t"' .

• j'

Station NO.,4, Consist4}~~of::', "'; '.16 - SP-567 -.'; _ ~,~\,,#.6-32 x 1/4 "Rd.Rd. Screw17 SCG-lI3 . JD::r.W~sherfi\-H3'18 SCG-l03 -·';1/-\'vi~~ssPlate.' ~,--19 SP:,,"2252 :#2 x 3/16 "Drive Screw20.: 96,P-02-0l0-l860 'N~mePlate,21' SCG-lOO Base22 SCG-l05 KeyBlocl( "23 SP-721 #10!32 x l/~,"Fil Rd. Screw

Station No.1, Consisting of:1 SCG-l04 Special Stud2 SCG-I0l Calibrated Indexing Body3 SCG-103 WitnessPlate4 SCG-113 Washer5 SP-567 #6-32 x 1/4 "Rd.Rd. Screw

Station No.2, Consisting of:6 SCG-104 Special Stud7 SCG-101 Calibrated Indexing Body8 SCG-103 WitnessPlate9 SCG-113 Washer

10 SP-567 #6-32 x 1/4 "Rd.Rd. Screw

. '"

Clamp Body24 SCG-I0425 SCG-I0226 SP-317

/;~;.:.- }{i<;p:-.~_, .

/C';';'SpecialStud __:,"';'.1 Clamp'BodY~'1'" ,_

5/16-1S··~.;~i~~~d. set.~~.

. :-;"~'_':~I:1Unit Parts

27282930

" "-,CWasher~eiW:asli~ ':. .jim'NutB :&:~Wrench'i> -'.~}

.•.

Station No.3, Consisting of:11 SCG-I04 Special Stud12 SCG-101 Calibrated Indexing Body13 SCG-103 WitnessPlate14 SCG-113 Washer15 SP-567 #6-32 x 1/4 "Rd.Rd. Screw

DP-276SR-234SCG-112Cat. #1524