CENTRE SCIENTIFIQUE ET TECHNIQUE DU BATIMENT 84 avenue Jean Jaurès – Champs-sur-Marne – 77447 Marne-la-Vallée Cedex 2 Tel. +33 (0)1 64 68 82 82 – www.cstb.fr MARNE-LA-VALLÉE / PARIS / GRENOBLE / NANTES / SOPHIA-ANTIPOLIS
TE
CH
NIC
AL
DO
CU
ME
NT
PVC Pipes
RIGID NON-PLASTICISED
PVC PIPES AND FITTINGS
Technical document No.°055-06 Specifications applicable to the Discharge of Rainwater
intended for Siphonic Drainage Systems Group
Technical document: 055-06 rev 00
21/12/2018
Technical document 055-06 rev 00 – page 2/24
Any reproduction or representation, in whole or in part, by whatever means, of the pages published in this technical document and executed without the authorisation of CSTB is
illegal and constitutes a counterfeit. The only authorised exceptions are 1) reproductions strictly reserved for the use of the typist and not intended for any collective use or 2)
analyses and short quotations required due to the scientific or informational nature of the work in which they appear (article L.122-5 of the Intellectual Property Code). This
document has been drawn up under the initiative and direction of CSTB, which has brought together the opinions of all interested parties..
© CSTB
CSTB (Centre Scientifique et Technique du Bâtiment), a public establishment supporting innovation in construction, has four key
activities—research, expertise, assessment and dissemination of knowledge—organised to meet the challenges of ecological and
energy transition in the construction sector. Its field of expertise includes construction materials, buildings and their integration into
districts and towns.
With over 900 employees, its subsidiaries and networks of national, European and international partners, the CSTB group works for
all the stakeholders in the construction sector to advance building quality and safety.
Technical document 055-06 rev 00 – page 3/24
MODIFICATION HISTORY
Revision no. Application
date
Modifications
00 21/12/2018 Update to the document layout and reference
Technical document 055-06 rev 00 – page 4/24
Table of contents
Partie 1. CHAMP D’APPLICATION............................................................................5
1.1 LES NORMES DE REFERENCES ET SPÉCIFICATIONS COMPLÉMENTAIRES APPLICABLES......Erreur ! Signet non défini.
Partie 2. MODALITES DE MARQUAGE – REFERENCES A LA MARQUE NF..........13
2.1 REPRODUCTION DU LOGO NF SUR LE PRODUIT CERTIFIE........................................................13
2.2 REPRODUCTION DU LOGO NF SUR L’EMBALLAGE DU PRODUIT CERTIFIE NF ........................17
2.3 MARQUAGE DES CARACTÉRISTIQUES CERTIFIÉES ET ASSOCIÉES.........................................18
2.4 REPRODUCTION DU LOGO NF SUR LA DOCUMENTATION ET DANS LES PUBLICITES (documents techniques et commerciaux, étiquettes, affiches, publicités, sites Internet, etc….)........18
Partie 3. EXIGENCES QUALITE DU DEMANDEUR / TITULAIRE ............................19
3.1 OPTION MAÎTRISE DE LA QUALITE..............................................................................................19
3.2 OPTION MANAGEMENT DE LA QUALITE.....................................................................................20
Partie 4. MODALITES DE SURVEILLANCE PAR LE CSTB......................................21
4.1 MODALITES D’ESSAIS LORS D’UNE DEMANDE D’ADMISSION..................................................21
4.2 MODALITÉS D’ESSAIS LORS DE LA SURVEILLANCE DES PRODUITS CERTIFIES.....................23
Technical document 055-06 rev 00 – page 5/24
Part 1. SCOPE
This Technical Document deals with the Discharge of Rainwater intended for Siphonic Drainage Systems Group.
1.1 APPLICABLE REFERENCE STANDARDS AND COMPLEMENTARY
SPECIFICATIONS
1.1.1 Reference standards
➢ Family - Solid-Wall PVC Pipes and Fittings
NF EN ISO 3126 (September 2005) Plastics piping systems — Plastics components — Determination of
dimensions.
NF T 54-030 (December 1981) Plastics – Unplasticised polyvinyl chloride moulded fittings for domestic water
drainage installations not subject to pressure — Specifications.
NF EN 1329-1 (July 1999) – Plastics piping systems for soil and waste discharge (low and high temperature)
within the building structure – Unplasticized poly(vinyl chloride) (PVC-U) – Part 1: Specifications for pipes,
fittings and the system.
1.1.2 Fields of application
The NF EN 1329-1 Standard specifies the requirements for the pipes and fittings indicated for drainage
applications defined below:
The pipes and fittings in the discharge of rainwater intended for siphonic systems group are used only for
producing drainage systems for rainwater using the siphon effect.
Using pipes and fittings from the discharge of rainwater intended for siphonic systems group for other applications
is not permitted.
Fittings obtained by welding multiple elements (forming) are excluded from this Technical Document.
1.1.3 Complementary specifications
The reference specifications and test methods for the NF Mark Rigid Non-Plasticised PVC Pipes and Fittings are
defined in the tables below. They are based on the abovementioned standards with possible additions or changes.
1.1.4 Admission ranges
The admission range presented during the 1st application must, at a minimum, include the following products:
Cases of pipes: 2 diameters
Cases of fittings: 3 types of fittings /DN and 2 DN minimum
This range may be produced on 1 or multiple sites with the same trade name.
This reference system is not intended to approve the consistency of diameters proposed to establish a functional
network.
Technical document 055-06 rev 00 – page 6/24
TABLE 1 - SOLID WALL PVC DISCHARGE OF RAINWATER, INTENDED FOR SIPHONIC
SYSTEMS FAMILIES
Pipes and Fittings Specifications
Characteristics and Test methods (4) Pipes Fittings
Reference standard
Appearance
Marking
NF EN 1329-1 NF T 54-030 ; NF EN 1329-1
(1) (1)
Dimensions (2) see table 3 see table 4
Socket depth
Colour Green (similar to RAL 6007)
Density
NF EN ISO 1183-1 Method A (2) 1370 to 1460 kg/m³
Vicat softening temperature
NF EN 727 (2) > 75°C (5)
Tensile properties
NF EN ISO 6259-1 and ISO 6259-2
(2)
Maximum stress
Elongation at break
TS > 45 MPa
E > 80%
Reversion at 150°C
NF EN ISO 2505 - (2) R < 5%
No blisters
Impact resistance
Pipes: NF EN 744 - method (2) TIR < 10%
Oven test at 150°C
NF EN ISO 580 - method
A (2) (3)
(1) The pipes and fittings may not have any defects visible to the naked eye such as scratches, marks, grains, cracks or
air pockets that negatively impact use.
The pipes and fittings must be a homogeneous green colour similar to the colour RAL 6007.
The marking must be consistent with the requirements provided in Technical Document 2 discharge of rainwater
intended for siphonic systems group.
(2) With additional clarifications indicated in Part 2 of Technical Document 1.
(3) The fittings may not have any openings along the entire thickness of their walls in any given welding line nor
deterioration of the surface, penetrating more than 1/2 the thickness of the wall, particularly near an injection point.
(4) The editions of the standards cited for use are those in force on the revision date of this certification reference
system (see page 2 of this Technical Document), unless otherwise specified by the Mandated Body.
(5) Siphonic systems being intended to convey exclusively rainwater, as explained in Standard NF EN 752, the
reference to the Vicat temperature is Standard NF EN 12200, relating to gutter downspouts.
Technical document 055-06 rev 00 – page 7/24
TABLE 2 - SOLID WALL PVC DISCHARGE OF RAINWATER, INTENDED FOR
SIPHONIC SYSTEMS FAMILIES
Specifications for assemblies
Characteristics and Test
methods (1)
Sealing ring assembly category Solvent welding
assembly category FIXED SLIP
Assembly composition and
dimensional characteristics
NF EN 1329-1 NF EN 1329-1
(table 11) (table 15) NF EN 1329-1
Leaktightness under negative
pressure (3)
NF EN 13844 (15 to 25°C, without deviation or
deformation)
Quality of elastomer sealing
rings
NF EN 681-1 (2)
NF EN 681-1
(1) The editions of the standards cited for use are those in force on the revision date of this certification reference
system (see page 2 of this Technical Document), unless otherwise specified by the Mandated Body.
(2) Ozone resistance test: Rubber sealing elements that are protected and packaged separately until the time of their
assembly must meet the same requirements, except using an ozone concentration of (25 ± 5) pphm instead of
(50 ± 5) pphm.
(3) Tests can be carried out on pipes and fittings from TD2 with the same dimensional characteristics.
Criteria: The change in negative pressure must be less than or equal to 0.05 bar during the first and second 15 min
periods (table 1 of Standard NF EN 1452-5 / clause 4.5).
Technical document 055-06 rev 00 – page 8/24
TABLE 3 - SOLID-WALL PVC DISCHARGE FAMILY
Dimensional characteristics of pipes with plain ends or sleeves
In accordance with NF EN ISO 3126 and NF EN 1329-1
- Length Tolerances: + 1% for L < 5 m
+ 5 cm for L > 5 m
- Socket: according to NF EN 1329-1 (only sockets for solvent-welding),
- Other dimensions
Average external
diameter DN
(mm)
Nominal
Thickness
Tolerances (mm)
th (mm) on DN Thicknesses on Dq (1)
th min th max (mm)
32 3.0 + 0.2
0 3.0 3.5 + 0.5
40 3.0 + 0.2
0 3.0 3.5 + 0.5
50 3.0 + 0.2
0 3.0 3.5 + 0.6
63 3.0 + 0.2
0 3.0 3.5 + 0.8
75 3.0 + 0.3
0 3.0 3.5 + 0.9
80 3.0 + 0.3
0 3.0 3.5 + 1.0
90 3.0 + 0.3
0 3.0 3.5
100 3.0 + 0.3
0 3.0 3.5
110 3.2 + 0.3
0 3.2 3.8
125 3.2 + 0.3
0 3.2 3.8
140 3.5 + 0.4
0 3.5 4.1
160 4.0 + 0.4
0 4.0 4.6
200 4.9 + 0.5
0 4.9 5.6
250 6.2 + 0.5
0 6.2 7.1
(1) Any external diameter (Da)
Technical document 055-06 rev 00 – page 9/24
TABLE 4 - SOLID-WALL PVC DISCHARGE FAMILY
Dimensional characteristics common to the fittings
Dimensional characteristics common to the fittings
DN
Spigot Socket Thickness
(min)
Average
External
Diameter
tolerances
Max. variation
of a given
diameter
Length of
socket h
Average
Internal
Diameter
tolerances
Maximum
out-of-
roundness
Socket
depth
L (1) (3)
Body of
the
fitting
Socket and
Spigots (2)
(mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm)
32 +0/+0.2 0.5 ≥22 +0.2/+0.4 0.35 22 3 2.0
40 +0/+0.2 0.5 ≥26 +0.2/+0.4 0.45 26 3 2.0
50 +0/+0.2 0.6 ≥31 +0.2/+0.4 0.55 31 3 2.0
63 +0/+0.2 0.8 ≥37.5 +0.2/+0.4 0.7 37.5 3 2.0
75 +0/+0.3 0.9 ≥43.5 +0.2/+0.5 0.8 43.5 3 2.0
80 +0/+0.3 1.0 ≥46 +0.2/+0.5 0.9 46 3 2.3
90 +0/+0.3 1.1 ≥51 +0.2/+0.5 1 51 3 2.3
100 +0/+0.3 1.2 ≥56 +0.2/+0.5 1.1 56 3 2.3
110 +0/+0.3 1.4 ≥60 +0.3/+0.6 1.2 ≥ 60 3.2 2.4
125 +0/+0.3 1.5 ≥60 +0.3/+0.6 1.4 ≥ 60 3.2 2.4
140 +0/+0.4 1.7 ≥60 +0.4/+0.7 1.55 ≥ 60 3.2 2.4
160 +0/+0.4 2.0 ≥60 +0.4/+0.7 1.75 ≥ 60 3.2 2.4
200 +0/+0.5 2.4 ≥ 60 +0.4/+0.9 2.2 ≥ 60 3.9 2.9
250 +0/+0.5 3 ≥ 60 +0.4/+0.9 2.75 ≥ 60 4.9 3.7
(1) Socket depth tolerances
+0/+2 (mm) for Ø ≤ 100
(2) Thickness of the sockets for solvent welding and the spigot
75 mm : th 2 mm
75 mm : th 0.75 times the thickness of the body
(3) Socket depths must be checked using go/no-go plug gauges; inspecting the socket depth of a fitting
must be carried out in order to ensure functionality of the fitting.
For solvent-weld fittings and sealing ring fittings, a 5% reduction in the thickness of the walls caused by core offset is permitted.
In such cases, the average of the thicknesses of the 2 opposing walls must be equal to or greater than the abovementioned values.
Other dimensions
Fittings defined in this technical document from captive, non-interchangeable systems: no Z-length is required, in accordance
with chapter 6.3.5 "Design lengths" of Standard NF EN 1329-1.
The design length(s) (Z-length) of fittings must be provided by the manufacturer.
Technical document 055-06 rev 00 – page 10/24
SOLID-WALL PVC DISCHARGE FAMILY
Dimensional characteristics of fittings (dimensions and tolerances in mm)
SOLVENT WELDING ASSEMBLY
Figures 8 and 9 in Standard NF EN 1329-1
Elbows 45° FF (Female-Female)
Elbows 45° MF (Male-Female)
(Fields of application: see page 3)
SOLID-WALL PVC DISCHARGE FAMILY
Dimensional characteristics of fittings (dimensions and tolerances in mm)
SOLVENT WELDING ASSEMBLY
Figures 10 and 11 in Standard NF EN 1329-1
Elbows 90° FF (Female-Female)
Elbows 90° MF (Male-Female)
(Fields of application: see page 3)
SOLID-WALL PVC DISCHARGE FAMILY
Dimensional characteristics of fittings (dimensions and tolerances in mm)
SOLVENT WELDING ASSEMBLY
Figures 14 and 15 in Standard NF EN 1329-1
Equal wyes 45° FFF
Equal wyes 45° MFF
Reducing wyes 45° FFF
Reducing wyes 45° MFF
(Fields of application: see page 3)
SOLID-WALL PVC DISCHARGE FAMILY
Dimensional characteristics of fittings (dimensions and tolerances in mm)
SOLVENT WELDING ASSEMBLY
Figure 13 in Standard NF EN 1329-1
Reducing eccentric sleeve couplings MF (Male-Female) and reducing plugs MF (Male-Female)
Short reducers MF (Male-Female)
(Field of application: see page 3)
SOLID-WALL PVC DISCHARGE FAMILY
Dimensional characteristics of fittings (dimensions and tolerances in mm)
SOLVENT WELDING ASSEMBLY
Figure 12 of Standard NF EN 1329-1
Equal sleeve couplings with stop and/or slip FF (Female-Female)
(Fields of application: see page 3)
Technical document 055-06 rev 00 – page 11/24
TABLE 5 - SOLID-WALL PVC DISCHARGE FAMILY
Dimensional characteristics of fittings (dimensions and tolerances in mm)
SLIP ASSEMBLY WITH SEALING RING
(NF T 54-030 AND NF EN 1329-1; TABLE 15)
(Fields of application: see page 3)
Diagram taken from Standard NF T 54 031, withdrawn on June 2002
These diagrams are provided for informational purposes regarding the shape of the seal; other designs may be considered.
Reuse the previous tables concerning outlet fittings for solvent welding assembly, replacing the information relating to the
sockets with the below specifications.
In particular, in the case of expansion sleeves, the dimensions of the spigots are those of the fittings for solvent welding.
Maximum offset 6°.
Technical document 055-06 rev 00 – page 12/24
Average internal diameters Depth
Nominal
diameter
D
of sockets
(minimum)
C
Guiding
H
tolerances:
+ 1.6
0
Socket
maximum
B
Chamber
minimum
A
Chamber
penetration
minimum
N
Minimum
thickness of
walls
(th)
32 32.3 32.3 115 65 50 2.0
40 40.3 40.3 115 65 50 2.0
50 50.3 50.3 115 65 50 2.0
63 63.3 63.3 115 65 50 2.0
75 75.3 75.3 115 65 50 2.3
90 90.3 90.3 115 65 50 2.3
100 100.4 100.4 115 65 50 2.3
110 110.4 110.4 115 65 50 2.4
125 125.4 125.4 115 65 50 2.4
140 140.5 140.5 115 65 50 2.4
160 160.5 160.5 115 65 50 2.4
200 200.5 200.5 115 65 50 2.9
250 250.5 250.5 115 65 50 3.7
The corresponding assembly dimensions are not standardised and are thus left to the manufacturer. They cannot be less than
those of the fittings for solvent welding assembly.
Technical document 055-06 rev 00 – page 13/24
Part 2. MARKING CONDITIONS – REFERENCING THE
NF MARK
This Technical Document specifies the conditions of marking and referencing the NF Mark provided in the
certification reference system of the NF Mark - Rigid Non-Plasticised PVC Pipes and Fittings.
2.1 REPRODUCING THE NF LOGO ON THE CERTIFIED PRODUCT
2.1.1 General
The NF logo shall ensure the identification of each certified product.
The trade reference of the certified product must be reserved for the NF mark.
The manufacturer must not use the NF mark except to single out certified products without there being any risk of
confusion whatsoever.
The logo’s graphic tools are available from the CSTB Technical Department (Tel.: +33 (0)1 64 68 89 52 – E-mail:
It is recommended that the holder remit to CSTB, in advance, all the documents upon which the NF mark appears.
The NF logo, constituting certification identification by a third party with regards to the reference standards cited
on page 2 of this Technical Document, must be affixed in accordance with the conditions defined in those
standards.
The black and white version of the NF logo can be used.
2.1.2 Marking pipes and fittings
2.1.2.1 Marking pipes
Marking of pipes must be carried out in a way that is visible and indelible and which can be read by the naked eye,
on a generatrix and contain, every meter or less, the following set of information:
- the trademark or symbol filed by the manufacturer with the mandated bodies.
- the manufacturer’s identification number assigned upon notification of admission and possibly the
production site designated upon notification of admission (if there are multiple factories).
- the monogram
or
and the symbol of the family (E for siphonic system
discharge pipes)
E or E
Holders have the option to use:
- Either the new logo followed by the letter E, as follows: E
- Or, as an exception, when using the logo creates technical and/or material difficulties, the old logo
Technical document 055-06 rev 00 – page 14/24
The black and white version of the NF logo can be used.
The new certified products shall comply with the NF graphic charter in force.
Note: a negative version of the logo can be used.
- the material identification symbol: PVC
- the pipe dimensions:
• for the siphonic systems Discharge family:
nominal external diameter x nominal thickness (or minimum) and the name "SIPHONIC".
- mark for production identification: date (dd/mm/yy) or day number and year of manufacture (xxx/yy)
(or batch no. indicating the manufacturing date: in this case, the definition of this number must be sent to
the mandated body).
Note: the choice of marking method is left to the manufacturer. Any other additional marking is permitted on the
condition that the sequence of NF information is not broken and it causes no confusion during use; in this case, the
sequence of NF information must be framed by three lines of approximately 3 cm.
Unless specifically authorised by the mandated body after consultation with the Application Committee, double-
marking products is prohibited when marking relates to an application that is not covered by the mark.
Examples:
Discharge Group
Pipes for discharge of rainwater intended for siphonic systems
XXX 02/01 E PVC 100 x 3.0 SIPHONIC 01 02 12 or 032 12-
Technical document 055-06 rev 00 – page 15/24
2.1.2.2 Marking fittings
b.1. Mandatory information on fittings
For fittings with diameters 50 mm
Each fitting must bear the following information, marked indelibly:
- trademark or symbol filed by the manufacturer with the mandated bodies.
- nominal dimensions (in the case of a single fitting or a reducing fitting; in the latter case, the order
indicated for the designation must be followed).
- values of connection angles.
Example:
If multiple trademarks are filed with the mandated bodies, the identification number of the manufacturer, assigned
upon notification of admission, must be mentioned in addition to the above information.
For fittings with diameters > 50 mm
Each fitting must bear the following information, marked indelibly:
- trademark or symbol filed by the manufacturer with the mandated bodies.
- nominal dimensions (in the case of a single fitting or a reducing fitting; in the latter case, the order
indicated for the designation must be followed).
- values of connection angles.
- NF monogram and family symbol arranged as shown below, notwithstanding the NF mark’s graphic
charter.
Holders have the option to use:
- Either the new logo followed by the letter E, as follows: E
- Or, as an exception, when using the logo creates technical and/or material difficulties, the following
monogram:
The black and white version of the NF logo can be used.
E
Technical document 055-06 rev 00 – page 16/24
In cases of FF sleeve couplings or if moulding conditions do not allow marking of the NF monogram described
above, this is optional, unless using the monogram E is possible.
Example:
If multiple trademarks are filed with the mandated bodies, the identification number of the manufacturer, assigned
upon notification of admission, must be mentioned in addition to the above information.
Note: the location of the marking and the methods used are left to the manufacturer. Any other additional marking
is permitted on the condition that its location is separate from the NF marking and it causes no confusion during
use.
b.2. Additional recommended information on fittings (optional)
Each fitting may bear the following information:
- the symbol identifying the material (PVC),
- a mark for production identification.
b.3. Marking primary packaging (Mandatory information)
Primary packaging must include the following indelibly marked information:
. Company name and/or trademark filed,
. Symbol identifying the material,
. NF monogram as defined below:
E or
E + M1 or E + Me if the
holder also has the reaction to fire NF mark
The black and white version of the NF logo can be used.
2.1.2.3. Cases of pipes and fittings that can belong to 2 families of this mark or covered by other NF marks or
another certification
Some products can be included in other domains of the NF mark: Mark – NF Reaction to Fire of materials
intended for buildings (PVC pipes and fittings).
Products holding other Fire NF marks can be marked with the corresponding logos from the reference systems in
question.
a) The marking principles are as follows:
Technical document 055-06 rev 00 – page 17/24
b) Cases of pipes
Pipes admitted to the NF mark - PVC Pipes and Fittings for the PVC Discharge families the material of which is
classified M1 or Me as part of the NF mark - Reaction to Fire: the marking on pipes is completed as follows, by
the "+" sign and the logo NF M1 or NF Me:
XXX 02/02 E + M1 PVC 100 x 3.0 SIPHONIC 01 02 11 or 032 11
XXX 02/02 E + Me PVC 100 x 3.0 SIPHONIC 01 02 11 or 032 11
XXX 02/02 E PVC 100 x 3.0 SIPHONIC 01 02 11 or 032 11
c) Case of fittings
Fittings admitted to the NF mark - PVC Pipes and Fittings for the PVC Discharge families, the material of which
is classified M1 or Me as part of the NF mark - Reaction to Fire: the NF monogram and the symbol of the family
as well as the NF mark - Reaction to Fire must be present as indicated below, all general marking principles
(paragraph 2.1.2) being unchanged.
or or
2.2 REPRODUCTION OF THE NF LOGO ON THE PACKAGING OF THE
NF-CERTIFIED PRODUCT
• The following NF monogram is to be used:
E
or
E + M1 or E + Me if the
holder also has the reaction to fire NF mark.
Products holding other Fire NF marks can be marked with the corresponding logos from the reference systems in
question.
E M1
E Me
E
Technical document 055-06 rev 00 – page 18/24
2.3 MARKING CERTIFIED AND ASSOCIATED CHARACTERISTICS
All documentation relating to an NF – Rigid Non-Plasticised PVC Pipes and Fittings certified product must use
the following form:
- Name and address of the manufacturer,
- Identification of the Reference System on which the certification is based (see 2.4.2 of the body of the
reference system),
- (Name and address of the delegate in France, if applicable),
- Designation of the product (trademark and trade reference),
- Licence or certificate number,
- The name or company name of the certification body or its collective Certification mark as well as its
address,
- Certified product characteristics:
- Dimensional characteristics (diameter, thickness, out-of-roundness, sockets),
- Tensile strength,
- Impact resistance,
- Leaktightness under negative pressure.
2.4 REPRODUCING THE NF LOGO ON DOCUMENTATION AND IN
ADVERTISING (technical and commercial documents, labels, posters,
advertising, Websites, etc.)
• The following NF monogram is to be used:
E
or
E + M1 or E + Me
if the holder also has the reaction to fire NF mark
The black and white version of the NF logo can be used.
Products holding other Fire NF marks can be marked with the corresponding logos from the reference systems in
question.
Technical document 055-06 rev 00 – page 19/24
Part 3. APPLICANT/HOLDER QUALITY REQUIREMENTS
3.1 QUALITY CONTROL OPTION
The tests specified in these tables are to be performed with the number of specimens stipulated in the testing
standards and addendums indicated in Technical Document 1 of this certification reference system specific to each
product group, unless otherwise indicated in the tables.
For pipes:
Table 6
Measurements or tests (1) Minimum sampling frequency Solid-
wall PVC
Dimensions: diameter,
thickness, out-of-roundness
Appearance
Colour
Marking
By extruder:
1 every 4 hours X
Density 1 test per month on 1 type at random (1) X
Vicat softening temperature 1 test every 3 months on 1 type at random (1) X
Tensile properties
By extruder:
1 test per campaign (1) (3) (4) X
Reversion 1 test on 1 specimen at the start of the campaign (2)
(3) (1) X
Impact resistance 1 test per campaign (2) (3) X
(1) Methods specified in Technical Document 1 part 2.
(2) Campaign: for each extruder, the period between the start of manufacturing of a product reference number
and the switch to the next number.
(3) Complete this test at least once a week (if the campaign lasts more than a week).
(4) Test to be completed on at least 5 specimens.
Technical document 055-06 rev 00 – page 20/24
For fittings:
TABLE 7
Measurements or tests (1) Minimum sampling frequency
Dimensions
(spigots and sockets)
Injected fittings:
- per machine, per type and per dimensions:
. Once every 4 hours, with increased inspections at the start
of the campaign (2 specimens during the first 2 hours of
production) (2)
Density Injected fittings:
1 test per month on 1 type at random
Vicat softening temperature Injected fittings:
1 test every 3 months on 1 type at random
Oven test 1 test on 1 specimen per day, per machine, per type and per
dimensions (2)
(1) Methods specified in Technical Document 1, Part 2.
(2) 1 specimen corresponding to as many fittings (cavities) as the mould used contains.
A campaign corresponds to the period between the start of manufacturing of a product reference number and the
switch to the next number.
3.2 QUALITY MANAGEMENT OPTION
The implemented quality assurance plan must enable product compliance with the specifications of the standards
and of this regulation.
Consequently, the manufacturer must complete or ensure completion of the specified tests per the frequencies
defined in the quality assurance plan, certain tests being able to be considered "type" tests (for putting new
equipment in place or using a new formulation, for example).
The dimensional quality control testing carried out on the same fittings from TD2 of this reference system are
deemed to satisfy the dimensional verifications of this reference system.
Technical document 055-06 rev 00 – page 21/24
Part 4. MONITORING ARRANGEMENTS BY CSTB
4.1 TEST PROCEDURES DURING AN APPLICATION FOR ADMISSION
For pipes in the Discharge family – Solid-Wall PVC pipes for rainwater intended for siphonic systems:
TABLE 8
Measurement or test Tests conducted in the factory Tests conducted in the
laboratory
Average external diameter*
Appearance
Marking
Colour
Length
Any diameter
Thickness
Sockets (depth of groove)
All the types submitted for
admission -
Density (1) 1 test (choice of type and
category) 1 test
Vicat softening temperature (1) 1 test (choice of type and
category) 1 test
Tensile characteristics (maximum stress and
elongation at break) (1)
1 test (choice of category),
except in the case where this test
is a type test
1 test per type sampled
Reversion at 150°C (1) 1 test (choice of category) 1 test per type sampled
Impact resistance (1) NF EN 744 1 test 1 test per type sampled
(1) With additional clarifications indicated in Technical Document 1, Part 2.
(*) Case of manufacturers holding the NF Mark TD2: the range admitted in TD6 being geometrically identical to the
range admitted in TD2, inspection of dimensions will not be performed. Only the TD6 range not matching TD2
will be inspected; this TD6 range is distinguished by angles and Z- and H-lengths different from those of TD2. A
list of this range shall be made available in the factories during an audit by the certification body.
Technical document 055-06 rev 00 – page 22/24
For fittings in the Discharge family – Solid-Wall PVC fittings for rainwater intended for siphonic
systems:
TABLE 9
Measurement or test Tests conducted in the factory Tests conducted in the
laboratory
Average external diameter**
Appearance
Marking
Colour
Thickness
Assembly dimension
Sockets
All the types submitted for
admission: by dimensional
inspection of stock on at least half
the range presented and by
verification of the inspection
registers for the entire range
-
Vicat softening temperature (1) 1 test 1 test
Density (1) 1 test 1 test
Oven test at 150°C (1) 1 test per fitting sampled (*) 1 test per fitting sampled (*)
Leaktightness under negative pressure - 1 test on 1 expansion sleeve
Quality of elastomer sealing rings -
1 report of tests provided by the
manufacturer of elastomer sealing
rings.
(1) With additional clarifications indicated in Technical Document 1, Part 2.
(*): Limited to 4 fittings.
(**) Case of manufacturers holding the NF Mark TD2: the range admitted in TD6 being geometrically identical to the range
admitted in TD2, inspection of dimensions will not be performed. Only the TD6 range not matching TD2 will be inspected;
this TD6 range is distinguished by angles and Z- and H-lengths different from those of TD2. A list of this range shall be
made available in the factories during an audit by the certification body.
Technical document 055-06 rev 00 – page 23/24
4.2 TEST PROCEDURES DURING MONITORING OF CERTIFIED
PRODUCTS
For pipes in the Discharge family – Solid-Wall PVC pipes for rainwater intended for siphonic systems:
TABLE 10
Measurement or test
Tests conducted in the factory Tests conducted in the
laboratory Quality control Quality management
Average external diameter
Appearance
Marking
Colour
Length
Any diameter
Thickness
Sockets (depth of groove)
5 types per visit divided between each family admitted
and product category -
Density (1) Inspection of test records 1 type per year
Vicat softening temperature (1) Inspection of test records 1 type per year
Tensile characteristics (maximum
stress and elongation at break) (1) Inspection of test records 1 type per year
Reversion at 150°C (1) 1 type at each visit
(choice of category)
1 type per year (choice of
category) 1 type per year
Impact resistance (1) NF EN 744 1 type at each visit
(choice of category)
1 type per year (choice of
category) 1 type per year
(1) With additional clarifications indicated in Technical Document 1, Part 2.
Technical document 055-06 rev 00 – page 24/24
For fittings in the Discharge family – Solid-Wall PVC fittings for rainwater intended for siphonic
systems:
TABLE 11
Measurement or test
Quality control
Quality management
Quality control Quality management
Appearance (2)
Marking
Colour
Average external diameter
Any diameter
Thickness of the fitting’s body
3 diameters per visit and per category (choice of type) -
Sockets 3 diameters per visit and per category (choice of type) -
Vicat softening temperature (1) Inspection of test records 1 diameter per year
Density (1) Inspection of test records 1 diameter per year
Oven test at 150°C (1)
3 diameters per visit
(choice of type and
category)
3 diameters per year
(choice of type and
category)
1 diameter per year
Leaktightness under negative
pressure - - 1 test on 1 expansion sleeve
(1) With additional clarifications indicated in Technical Document 1, Part 2.
(2) Case of manufacturers holding the NF Mark TD2: the range admitted in TD6 being geometrically identical to the
range admitted in TD2, inspection of dimensions will not be performed. Only the TD6 range not matching TD2
will be inspected; this TD6 range is distinguished by angles and Z- and H-lengths different from those of TD2. A
list of this range shall be made available in the factories during an audit by the certification body.