CENTRE SCIENTIFIQUE ET TECHNIQUE DU BATIMENT 84 avenue Jean Jaurès Champs-sur-Marne 77447 Marne-la-Vallée Cedex 2 Tel. +33 (0)1 64 68 82 82 www.cstb.fr MARNE-LA-VALLÉE / PARIS / GRENOBLE / NANTES / SOPHIA-ANTIPOLIS TECHNICAL DOCUMENT PVC Pipes RIGID NON-PLASTICISED PVC PIPES AND FITTINGS Technical document No.°055-06 Specifications applicable to the Discharge of Rainwater intended for Siphonic Drainage Systems Group Technical document: 055-06 rev 00 21/12/2018

RIGID NON-PLASTICISED PVC PIPES AND FITTINGS ......The reference specifications and test methods for the NF Mark Rigid Non-Plasticised PVC Pipes and Fittings are defined in the tables

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: RIGID NON-PLASTICISED PVC PIPES AND FITTINGS ......The reference specifications and test methods for the NF Mark Rigid Non-Plasticised PVC Pipes and Fittings are defined in the tables

CENTRE SCIENTIFIQUE ET TECHNIQUE DU BATIMENT 84 avenue Jean Jaurès – Champs-sur-Marne – 77447 Marne-la-Vallée Cedex 2 Tel. +33 (0)1 64 68 82 82 – www.cstb.fr MARNE-LA-VALLÉE / PARIS / GRENOBLE / NANTES / SOPHIA-ANTIPOLIS

TE

CH

NIC

AL

DO

CU

ME

NT

PVC Pipes

RIGID NON-PLASTICISED

PVC PIPES AND FITTINGS

Technical document No.°055-06 Specifications applicable to the Discharge of Rainwater

intended for Siphonic Drainage Systems Group

Technical document: 055-06 rev 00

21/12/2018

Page 2: RIGID NON-PLASTICISED PVC PIPES AND FITTINGS ......The reference specifications and test methods for the NF Mark Rigid Non-Plasticised PVC Pipes and Fittings are defined in the tables

Technical document 055-06 rev 00 – page 2/24

Any reproduction or representation, in whole or in part, by whatever means, of the pages published in this technical document and executed without the authorisation of CSTB is

illegal and constitutes a counterfeit. The only authorised exceptions are 1) reproductions strictly reserved for the use of the typist and not intended for any collective use or 2)

analyses and short quotations required due to the scientific or informational nature of the work in which they appear (article L.122-5 of the Intellectual Property Code). This

document has been drawn up under the initiative and direction of CSTB, which has brought together the opinions of all interested parties..

© CSTB

CSTB (Centre Scientifique et Technique du Bâtiment), a public establishment supporting innovation in construction, has four key

activities—research, expertise, assessment and dissemination of knowledge—organised to meet the challenges of ecological and

energy transition in the construction sector. Its field of expertise includes construction materials, buildings and their integration into

districts and towns.

With over 900 employees, its subsidiaries and networks of national, European and international partners, the CSTB group works for

all the stakeholders in the construction sector to advance building quality and safety.

Page 3: RIGID NON-PLASTICISED PVC PIPES AND FITTINGS ......The reference specifications and test methods for the NF Mark Rigid Non-Plasticised PVC Pipes and Fittings are defined in the tables

Technical document 055-06 rev 00 – page 3/24

MODIFICATION HISTORY

Revision no. Application

date

Modifications

00 21/12/2018 Update to the document layout and reference

Page 4: RIGID NON-PLASTICISED PVC PIPES AND FITTINGS ......The reference specifications and test methods for the NF Mark Rigid Non-Plasticised PVC Pipes and Fittings are defined in the tables

Technical document 055-06 rev 00 – page 4/24

Table of contents

Partie 1. CHAMP D’APPLICATION............................................................................5

1.1 LES NORMES DE REFERENCES ET SPÉCIFICATIONS COMPLÉMENTAIRES APPLICABLES......Erreur ! Signet non défini.

Partie 2. MODALITES DE MARQUAGE – REFERENCES A LA MARQUE NF..........13

2.1 REPRODUCTION DU LOGO NF SUR LE PRODUIT CERTIFIE........................................................13

2.2 REPRODUCTION DU LOGO NF SUR L’EMBALLAGE DU PRODUIT CERTIFIE NF ........................17

2.3 MARQUAGE DES CARACTÉRISTIQUES CERTIFIÉES ET ASSOCIÉES.........................................18

2.4 REPRODUCTION DU LOGO NF SUR LA DOCUMENTATION ET DANS LES PUBLICITES (documents techniques et commerciaux, étiquettes, affiches, publicités, sites Internet, etc….)........18

Partie 3. EXIGENCES QUALITE DU DEMANDEUR / TITULAIRE ............................19

3.1 OPTION MAÎTRISE DE LA QUALITE..............................................................................................19

3.2 OPTION MANAGEMENT DE LA QUALITE.....................................................................................20

Partie 4. MODALITES DE SURVEILLANCE PAR LE CSTB......................................21

4.1 MODALITES D’ESSAIS LORS D’UNE DEMANDE D’ADMISSION..................................................21

4.2 MODALITÉS D’ESSAIS LORS DE LA SURVEILLANCE DES PRODUITS CERTIFIES.....................23

Page 5: RIGID NON-PLASTICISED PVC PIPES AND FITTINGS ......The reference specifications and test methods for the NF Mark Rigid Non-Plasticised PVC Pipes and Fittings are defined in the tables

Technical document 055-06 rev 00 – page 5/24

Part 1. SCOPE

This Technical Document deals with the Discharge of Rainwater intended for Siphonic Drainage Systems Group.

1.1 APPLICABLE REFERENCE STANDARDS AND COMPLEMENTARY

SPECIFICATIONS

1.1.1 Reference standards

➢ Family - Solid-Wall PVC Pipes and Fittings

NF EN ISO 3126 (September 2005) Plastics piping systems — Plastics components — Determination of

dimensions.

NF T 54-030 (December 1981) Plastics – Unplasticised polyvinyl chloride moulded fittings for domestic water

drainage installations not subject to pressure — Specifications.

NF EN 1329-1 (July 1999) – Plastics piping systems for soil and waste discharge (low and high temperature)

within the building structure – Unplasticized poly(vinyl chloride) (PVC-U) – Part 1: Specifications for pipes,

fittings and the system.

1.1.2 Fields of application

The NF EN 1329-1 Standard specifies the requirements for the pipes and fittings indicated for drainage

applications defined below:

The pipes and fittings in the discharge of rainwater intended for siphonic systems group are used only for

producing drainage systems for rainwater using the siphon effect.

Using pipes and fittings from the discharge of rainwater intended for siphonic systems group for other applications

is not permitted.

Fittings obtained by welding multiple elements (forming) are excluded from this Technical Document.

1.1.3 Complementary specifications

The reference specifications and test methods for the NF Mark Rigid Non-Plasticised PVC Pipes and Fittings are

defined in the tables below. They are based on the abovementioned standards with possible additions or changes.

1.1.4 Admission ranges

The admission range presented during the 1st application must, at a minimum, include the following products:

Cases of pipes: 2 diameters

Cases of fittings: 3 types of fittings /DN and 2 DN minimum

This range may be produced on 1 or multiple sites with the same trade name.

This reference system is not intended to approve the consistency of diameters proposed to establish a functional

network.

Page 6: RIGID NON-PLASTICISED PVC PIPES AND FITTINGS ......The reference specifications and test methods for the NF Mark Rigid Non-Plasticised PVC Pipes and Fittings are defined in the tables

Technical document 055-06 rev 00 – page 6/24

TABLE 1 - SOLID WALL PVC DISCHARGE OF RAINWATER, INTENDED FOR SIPHONIC

SYSTEMS FAMILIES

Pipes and Fittings Specifications

Characteristics and Test methods (4) Pipes Fittings

Reference standard

Appearance

Marking

NF EN 1329-1 NF T 54-030 ; NF EN 1329-1

(1) (1)

Dimensions (2) see table 3 see table 4

Socket depth

Colour Green (similar to RAL 6007)

Density

NF EN ISO 1183-1 Method A (2) 1370 to 1460 kg/m³

Vicat softening temperature

NF EN 727 (2) > 75°C (5)

Tensile properties

NF EN ISO 6259-1 and ISO 6259-2

(2)

Maximum stress

Elongation at break

TS > 45 MPa

E > 80%

Reversion at 150°C

NF EN ISO 2505 - (2) R < 5%

No blisters

Impact resistance

Pipes: NF EN 744 - method (2) TIR < 10%

Oven test at 150°C

NF EN ISO 580 - method

A (2) (3)

(1) The pipes and fittings may not have any defects visible to the naked eye such as scratches, marks, grains, cracks or

air pockets that negatively impact use.

The pipes and fittings must be a homogeneous green colour similar to the colour RAL 6007.

The marking must be consistent with the requirements provided in Technical Document 2 discharge of rainwater

intended for siphonic systems group.

(2) With additional clarifications indicated in Part 2 of Technical Document 1.

(3) The fittings may not have any openings along the entire thickness of their walls in any given welding line nor

deterioration of the surface, penetrating more than 1/2 the thickness of the wall, particularly near an injection point.

(4) The editions of the standards cited for use are those in force on the revision date of this certification reference

system (see page 2 of this Technical Document), unless otherwise specified by the Mandated Body.

(5) Siphonic systems being intended to convey exclusively rainwater, as explained in Standard NF EN 752, the

reference to the Vicat temperature is Standard NF EN 12200, relating to gutter downspouts.

Page 7: RIGID NON-PLASTICISED PVC PIPES AND FITTINGS ......The reference specifications and test methods for the NF Mark Rigid Non-Plasticised PVC Pipes and Fittings are defined in the tables

Technical document 055-06 rev 00 – page 7/24

TABLE 2 - SOLID WALL PVC DISCHARGE OF RAINWATER, INTENDED FOR

SIPHONIC SYSTEMS FAMILIES

Specifications for assemblies

Characteristics and Test

methods (1)

Sealing ring assembly category Solvent welding

assembly category FIXED SLIP

Assembly composition and

dimensional characteristics

NF EN 1329-1 NF EN 1329-1

(table 11) (table 15) NF EN 1329-1

Leaktightness under negative

pressure (3)

NF EN 13844 (15 to 25°C, without deviation or

deformation)

Quality of elastomer sealing

rings

NF EN 681-1 (2)

NF EN 681-1

(1) The editions of the standards cited for use are those in force on the revision date of this certification reference

system (see page 2 of this Technical Document), unless otherwise specified by the Mandated Body.

(2) Ozone resistance test: Rubber sealing elements that are protected and packaged separately until the time of their

assembly must meet the same requirements, except using an ozone concentration of (25 ± 5) pphm instead of

(50 ± 5) pphm.

(3) Tests can be carried out on pipes and fittings from TD2 with the same dimensional characteristics.

Criteria: The change in negative pressure must be less than or equal to 0.05 bar during the first and second 15 min

periods (table 1 of Standard NF EN 1452-5 / clause 4.5).

Page 8: RIGID NON-PLASTICISED PVC PIPES AND FITTINGS ......The reference specifications and test methods for the NF Mark Rigid Non-Plasticised PVC Pipes and Fittings are defined in the tables

Technical document 055-06 rev 00 – page 8/24

TABLE 3 - SOLID-WALL PVC DISCHARGE FAMILY

Dimensional characteristics of pipes with plain ends or sleeves

In accordance with NF EN ISO 3126 and NF EN 1329-1

- Length Tolerances: + 1% for L < 5 m

+ 5 cm for L > 5 m

- Socket: according to NF EN 1329-1 (only sockets for solvent-welding),

- Other dimensions

Average external

diameter DN

(mm)

Nominal

Thickness

Tolerances (mm)

th (mm) on DN Thicknesses on Dq (1)

th min th max (mm)

32 3.0 + 0.2

0 3.0 3.5 + 0.5

40 3.0 + 0.2

0 3.0 3.5 + 0.5

50 3.0 + 0.2

0 3.0 3.5 + 0.6

63 3.0 + 0.2

0 3.0 3.5 + 0.8

75 3.0 + 0.3

0 3.0 3.5 + 0.9

80 3.0 + 0.3

0 3.0 3.5 + 1.0

90 3.0 + 0.3

0 3.0 3.5

100 3.0 + 0.3

0 3.0 3.5

110 3.2 + 0.3

0 3.2 3.8

125 3.2 + 0.3

0 3.2 3.8

140 3.5 + 0.4

0 3.5 4.1

160 4.0 + 0.4

0 4.0 4.6

200 4.9 + 0.5

0 4.9 5.6

250 6.2 + 0.5

0 6.2 7.1

(1) Any external diameter (Da)

Page 9: RIGID NON-PLASTICISED PVC PIPES AND FITTINGS ......The reference specifications and test methods for the NF Mark Rigid Non-Plasticised PVC Pipes and Fittings are defined in the tables

Technical document 055-06 rev 00 – page 9/24

TABLE 4 - SOLID-WALL PVC DISCHARGE FAMILY

Dimensional characteristics common to the fittings

Dimensional characteristics common to the fittings

DN

Spigot Socket Thickness

(min)

Average

External

Diameter

tolerances

Max. variation

of a given

diameter

Length of

socket h

Average

Internal

Diameter

tolerances

Maximum

out-of-

roundness

Socket

depth

L (1) (3)

Body of

the

fitting

Socket and

Spigots (2)

(mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm)

32 +0/+0.2 0.5 ≥22 +0.2/+0.4 0.35 22 3 2.0

40 +0/+0.2 0.5 ≥26 +0.2/+0.4 0.45 26 3 2.0

50 +0/+0.2 0.6 ≥31 +0.2/+0.4 0.55 31 3 2.0

63 +0/+0.2 0.8 ≥37.5 +0.2/+0.4 0.7 37.5 3 2.0

75 +0/+0.3 0.9 ≥43.5 +0.2/+0.5 0.8 43.5 3 2.0

80 +0/+0.3 1.0 ≥46 +0.2/+0.5 0.9 46 3 2.3

90 +0/+0.3 1.1 ≥51 +0.2/+0.5 1 51 3 2.3

100 +0/+0.3 1.2 ≥56 +0.2/+0.5 1.1 56 3 2.3

110 +0/+0.3 1.4 ≥60 +0.3/+0.6 1.2 ≥ 60 3.2 2.4

125 +0/+0.3 1.5 ≥60 +0.3/+0.6 1.4 ≥ 60 3.2 2.4

140 +0/+0.4 1.7 ≥60 +0.4/+0.7 1.55 ≥ 60 3.2 2.4

160 +0/+0.4 2.0 ≥60 +0.4/+0.7 1.75 ≥ 60 3.2 2.4

200 +0/+0.5 2.4 ≥ 60 +0.4/+0.9 2.2 ≥ 60 3.9 2.9

250 +0/+0.5 3 ≥ 60 +0.4/+0.9 2.75 ≥ 60 4.9 3.7

(1) Socket depth tolerances

+0/+2 (mm) for Ø ≤ 100

(2) Thickness of the sockets for solvent welding and the spigot

75 mm : th 2 mm

75 mm : th 0.75 times the thickness of the body

(3) Socket depths must be checked using go/no-go plug gauges; inspecting the socket depth of a fitting

must be carried out in order to ensure functionality of the fitting.

For solvent-weld fittings and sealing ring fittings, a 5% reduction in the thickness of the walls caused by core offset is permitted.

In such cases, the average of the thicknesses of the 2 opposing walls must be equal to or greater than the abovementioned values.

Other dimensions

Fittings defined in this technical document from captive, non-interchangeable systems: no Z-length is required, in accordance

with chapter 6.3.5 "Design lengths" of Standard NF EN 1329-1.

The design length(s) (Z-length) of fittings must be provided by the manufacturer.

Page 10: RIGID NON-PLASTICISED PVC PIPES AND FITTINGS ......The reference specifications and test methods for the NF Mark Rigid Non-Plasticised PVC Pipes and Fittings are defined in the tables

Technical document 055-06 rev 00 – page 10/24

SOLID-WALL PVC DISCHARGE FAMILY

Dimensional characteristics of fittings (dimensions and tolerances in mm)

SOLVENT WELDING ASSEMBLY

Figures 8 and 9 in Standard NF EN 1329-1

Elbows 45° FF (Female-Female)

Elbows 45° MF (Male-Female)

(Fields of application: see page 3)

SOLID-WALL PVC DISCHARGE FAMILY

Dimensional characteristics of fittings (dimensions and tolerances in mm)

SOLVENT WELDING ASSEMBLY

Figures 10 and 11 in Standard NF EN 1329-1

Elbows 90° FF (Female-Female)

Elbows 90° MF (Male-Female)

(Fields of application: see page 3)

SOLID-WALL PVC DISCHARGE FAMILY

Dimensional characteristics of fittings (dimensions and tolerances in mm)

SOLVENT WELDING ASSEMBLY

Figures 14 and 15 in Standard NF EN 1329-1

Equal wyes 45° FFF

Equal wyes 45° MFF

Reducing wyes 45° FFF

Reducing wyes 45° MFF

(Fields of application: see page 3)

SOLID-WALL PVC DISCHARGE FAMILY

Dimensional characteristics of fittings (dimensions and tolerances in mm)

SOLVENT WELDING ASSEMBLY

Figure 13 in Standard NF EN 1329-1

Reducing eccentric sleeve couplings MF (Male-Female) and reducing plugs MF (Male-Female)

Short reducers MF (Male-Female)

(Field of application: see page 3)

SOLID-WALL PVC DISCHARGE FAMILY

Dimensional characteristics of fittings (dimensions and tolerances in mm)

SOLVENT WELDING ASSEMBLY

Figure 12 of Standard NF EN 1329-1

Equal sleeve couplings with stop and/or slip FF (Female-Female)

(Fields of application: see page 3)

Page 11: RIGID NON-PLASTICISED PVC PIPES AND FITTINGS ......The reference specifications and test methods for the NF Mark Rigid Non-Plasticised PVC Pipes and Fittings are defined in the tables

Technical document 055-06 rev 00 – page 11/24

TABLE 5 - SOLID-WALL PVC DISCHARGE FAMILY

Dimensional characteristics of fittings (dimensions and tolerances in mm)

SLIP ASSEMBLY WITH SEALING RING

(NF T 54-030 AND NF EN 1329-1; TABLE 15)

(Fields of application: see page 3)

Diagram taken from Standard NF T 54 031, withdrawn on June 2002

These diagrams are provided for informational purposes regarding the shape of the seal; other designs may be considered.

Reuse the previous tables concerning outlet fittings for solvent welding assembly, replacing the information relating to the

sockets with the below specifications.

In particular, in the case of expansion sleeves, the dimensions of the spigots are those of the fittings for solvent welding.

Maximum offset 6°.

Page 12: RIGID NON-PLASTICISED PVC PIPES AND FITTINGS ......The reference specifications and test methods for the NF Mark Rigid Non-Plasticised PVC Pipes and Fittings are defined in the tables

Technical document 055-06 rev 00 – page 12/24

Average internal diameters Depth

Nominal

diameter

D

of sockets

(minimum)

C

Guiding

H

tolerances:

+ 1.6

0

Socket

maximum

B

Chamber

minimum

A

Chamber

penetration

minimum

N

Minimum

thickness of

walls

(th)

32 32.3 32.3 115 65 50 2.0

40 40.3 40.3 115 65 50 2.0

50 50.3 50.3 115 65 50 2.0

63 63.3 63.3 115 65 50 2.0

75 75.3 75.3 115 65 50 2.3

90 90.3 90.3 115 65 50 2.3

100 100.4 100.4 115 65 50 2.3

110 110.4 110.4 115 65 50 2.4

125 125.4 125.4 115 65 50 2.4

140 140.5 140.5 115 65 50 2.4

160 160.5 160.5 115 65 50 2.4

200 200.5 200.5 115 65 50 2.9

250 250.5 250.5 115 65 50 3.7

The corresponding assembly dimensions are not standardised and are thus left to the manufacturer. They cannot be less than

those of the fittings for solvent welding assembly.

Page 13: RIGID NON-PLASTICISED PVC PIPES AND FITTINGS ......The reference specifications and test methods for the NF Mark Rigid Non-Plasticised PVC Pipes and Fittings are defined in the tables

Technical document 055-06 rev 00 – page 13/24

Part 2. MARKING CONDITIONS – REFERENCING THE

NF MARK

This Technical Document specifies the conditions of marking and referencing the NF Mark provided in the

certification reference system of the NF Mark - Rigid Non-Plasticised PVC Pipes and Fittings.

2.1 REPRODUCING THE NF LOGO ON THE CERTIFIED PRODUCT

2.1.1 General

The NF logo shall ensure the identification of each certified product.

The trade reference of the certified product must be reserved for the NF mark.

The manufacturer must not use the NF mark except to single out certified products without there being any risk of

confusion whatsoever.

The logo’s graphic tools are available from the CSTB Technical Department (Tel.: +33 (0)1 64 68 89 52 – E-mail:

[email protected]).

It is recommended that the holder remit to CSTB, in advance, all the documents upon which the NF mark appears.

The NF logo, constituting certification identification by a third party with regards to the reference standards cited

on page 2 of this Technical Document, must be affixed in accordance with the conditions defined in those

standards.

The black and white version of the NF logo can be used.

2.1.2 Marking pipes and fittings

2.1.2.1 Marking pipes

Marking of pipes must be carried out in a way that is visible and indelible and which can be read by the naked eye,

on a generatrix and contain, every meter or less, the following set of information:

- the trademark or symbol filed by the manufacturer with the mandated bodies.

- the manufacturer’s identification number assigned upon notification of admission and possibly the

production site designated upon notification of admission (if there are multiple factories).

- the monogram

or

and the symbol of the family (E for siphonic system

discharge pipes)

E or E

Holders have the option to use:

- Either the new logo followed by the letter E, as follows: E

- Or, as an exception, when using the logo creates technical and/or material difficulties, the old logo

Page 14: RIGID NON-PLASTICISED PVC PIPES AND FITTINGS ......The reference specifications and test methods for the NF Mark Rigid Non-Plasticised PVC Pipes and Fittings are defined in the tables

Technical document 055-06 rev 00 – page 14/24

The black and white version of the NF logo can be used.

The new certified products shall comply with the NF graphic charter in force.

Note: a negative version of the logo can be used.

- the material identification symbol: PVC

- the pipe dimensions:

• for the siphonic systems Discharge family:

nominal external diameter x nominal thickness (or minimum) and the name "SIPHONIC".

- mark for production identification: date (dd/mm/yy) or day number and year of manufacture (xxx/yy)

(or batch no. indicating the manufacturing date: in this case, the definition of this number must be sent to

the mandated body).

Note: the choice of marking method is left to the manufacturer. Any other additional marking is permitted on the

condition that the sequence of NF information is not broken and it causes no confusion during use; in this case, the

sequence of NF information must be framed by three lines of approximately 3 cm.

Unless specifically authorised by the mandated body after consultation with the Application Committee, double-

marking products is prohibited when marking relates to an application that is not covered by the mark.

Examples:

Discharge Group

Pipes for discharge of rainwater intended for siphonic systems

XXX 02/01 E PVC 100 x 3.0 SIPHONIC 01 02 12 or 032 12-

Page 15: RIGID NON-PLASTICISED PVC PIPES AND FITTINGS ......The reference specifications and test methods for the NF Mark Rigid Non-Plasticised PVC Pipes and Fittings are defined in the tables

Technical document 055-06 rev 00 – page 15/24

2.1.2.2 Marking fittings

b.1. Mandatory information on fittings

For fittings with diameters 50 mm

Each fitting must bear the following information, marked indelibly:

- trademark or symbol filed by the manufacturer with the mandated bodies.

- nominal dimensions (in the case of a single fitting or a reducing fitting; in the latter case, the order

indicated for the designation must be followed).

- values of connection angles.

Example:

If multiple trademarks are filed with the mandated bodies, the identification number of the manufacturer, assigned

upon notification of admission, must be mentioned in addition to the above information.

For fittings with diameters > 50 mm

Each fitting must bear the following information, marked indelibly:

- trademark or symbol filed by the manufacturer with the mandated bodies.

- nominal dimensions (in the case of a single fitting or a reducing fitting; in the latter case, the order

indicated for the designation must be followed).

- values of connection angles.

- NF monogram and family symbol arranged as shown below, notwithstanding the NF mark’s graphic

charter.

Holders have the option to use:

- Either the new logo followed by the letter E, as follows: E

- Or, as an exception, when using the logo creates technical and/or material difficulties, the following

monogram:

The black and white version of the NF logo can be used.

E

Page 16: RIGID NON-PLASTICISED PVC PIPES AND FITTINGS ......The reference specifications and test methods for the NF Mark Rigid Non-Plasticised PVC Pipes and Fittings are defined in the tables

Technical document 055-06 rev 00 – page 16/24

In cases of FF sleeve couplings or if moulding conditions do not allow marking of the NF monogram described

above, this is optional, unless using the monogram E is possible.

Example:

If multiple trademarks are filed with the mandated bodies, the identification number of the manufacturer, assigned

upon notification of admission, must be mentioned in addition to the above information.

Note: the location of the marking and the methods used are left to the manufacturer. Any other additional marking

is permitted on the condition that its location is separate from the NF marking and it causes no confusion during

use.

b.2. Additional recommended information on fittings (optional)

Each fitting may bear the following information:

- the symbol identifying the material (PVC),

- a mark for production identification.

b.3. Marking primary packaging (Mandatory information)

Primary packaging must include the following indelibly marked information:

. Company name and/or trademark filed,

. Symbol identifying the material,

. NF monogram as defined below:

E or

E + M1 or E + Me if the

holder also has the reaction to fire NF mark

The black and white version of the NF logo can be used.

2.1.2.3. Cases of pipes and fittings that can belong to 2 families of this mark or covered by other NF marks or

another certification

Some products can be included in other domains of the NF mark: Mark – NF Reaction to Fire of materials

intended for buildings (PVC pipes and fittings).

Products holding other Fire NF marks can be marked with the corresponding logos from the reference systems in

question.

a) The marking principles are as follows:

Page 17: RIGID NON-PLASTICISED PVC PIPES AND FITTINGS ......The reference specifications and test methods for the NF Mark Rigid Non-Plasticised PVC Pipes and Fittings are defined in the tables

Technical document 055-06 rev 00 – page 17/24

b) Cases of pipes

Pipes admitted to the NF mark - PVC Pipes and Fittings for the PVC Discharge families the material of which is

classified M1 or Me as part of the NF mark - Reaction to Fire: the marking on pipes is completed as follows, by

the "+" sign and the logo NF M1 or NF Me:

XXX 02/02 E + M1 PVC 100 x 3.0 SIPHONIC 01 02 11 or 032 11

XXX 02/02 E + Me PVC 100 x 3.0 SIPHONIC 01 02 11 or 032 11

XXX 02/02 E PVC 100 x 3.0 SIPHONIC 01 02 11 or 032 11

c) Case of fittings

Fittings admitted to the NF mark - PVC Pipes and Fittings for the PVC Discharge families, the material of which

is classified M1 or Me as part of the NF mark - Reaction to Fire: the NF monogram and the symbol of the family

as well as the NF mark - Reaction to Fire must be present as indicated below, all general marking principles

(paragraph 2.1.2) being unchanged.

or or

2.2 REPRODUCTION OF THE NF LOGO ON THE PACKAGING OF THE

NF-CERTIFIED PRODUCT

• The following NF monogram is to be used:

E

or

E + M1 or E + Me if the

holder also has the reaction to fire NF mark.

Products holding other Fire NF marks can be marked with the corresponding logos from the reference systems in

question.

E M1

E Me

E

Page 18: RIGID NON-PLASTICISED PVC PIPES AND FITTINGS ......The reference specifications and test methods for the NF Mark Rigid Non-Plasticised PVC Pipes and Fittings are defined in the tables

Technical document 055-06 rev 00 – page 18/24

2.3 MARKING CERTIFIED AND ASSOCIATED CHARACTERISTICS

All documentation relating to an NF – Rigid Non-Plasticised PVC Pipes and Fittings certified product must use

the following form:

- Name and address of the manufacturer,

- Identification of the Reference System on which the certification is based (see 2.4.2 of the body of the

reference system),

- (Name and address of the delegate in France, if applicable),

- Designation of the product (trademark and trade reference),

- Licence or certificate number,

- The name or company name of the certification body or its collective Certification mark as well as its

address,

- Certified product characteristics:

- Dimensional characteristics (diameter, thickness, out-of-roundness, sockets),

- Tensile strength,

- Impact resistance,

- Leaktightness under negative pressure.

2.4 REPRODUCING THE NF LOGO ON DOCUMENTATION AND IN

ADVERTISING (technical and commercial documents, labels, posters,

advertising, Websites, etc.)

• The following NF monogram is to be used:

E

or

E + M1 or E + Me

if the holder also has the reaction to fire NF mark

The black and white version of the NF logo can be used.

Products holding other Fire NF marks can be marked with the corresponding logos from the reference systems in

question.

Page 19: RIGID NON-PLASTICISED PVC PIPES AND FITTINGS ......The reference specifications and test methods for the NF Mark Rigid Non-Plasticised PVC Pipes and Fittings are defined in the tables

Technical document 055-06 rev 00 – page 19/24

Part 3. APPLICANT/HOLDER QUALITY REQUIREMENTS

3.1 QUALITY CONTROL OPTION

The tests specified in these tables are to be performed with the number of specimens stipulated in the testing

standards and addendums indicated in Technical Document 1 of this certification reference system specific to each

product group, unless otherwise indicated in the tables.

For pipes:

Table 6

Measurements or tests (1) Minimum sampling frequency Solid-

wall PVC

Dimensions: diameter,

thickness, out-of-roundness

Appearance

Colour

Marking

By extruder:

1 every 4 hours X

Density 1 test per month on 1 type at random (1) X

Vicat softening temperature 1 test every 3 months on 1 type at random (1) X

Tensile properties

By extruder:

1 test per campaign (1) (3) (4) X

Reversion 1 test on 1 specimen at the start of the campaign (2)

(3) (1) X

Impact resistance 1 test per campaign (2) (3) X

(1) Methods specified in Technical Document 1 part 2.

(2) Campaign: for each extruder, the period between the start of manufacturing of a product reference number

and the switch to the next number.

(3) Complete this test at least once a week (if the campaign lasts more than a week).

(4) Test to be completed on at least 5 specimens.

Page 20: RIGID NON-PLASTICISED PVC PIPES AND FITTINGS ......The reference specifications and test methods for the NF Mark Rigid Non-Plasticised PVC Pipes and Fittings are defined in the tables

Technical document 055-06 rev 00 – page 20/24

For fittings:

TABLE 7

Measurements or tests (1) Minimum sampling frequency

Dimensions

(spigots and sockets)

Injected fittings:

- per machine, per type and per dimensions:

. Once every 4 hours, with increased inspections at the start

of the campaign (2 specimens during the first 2 hours of

production) (2)

Density Injected fittings:

1 test per month on 1 type at random

Vicat softening temperature Injected fittings:

1 test every 3 months on 1 type at random

Oven test 1 test on 1 specimen per day, per machine, per type and per

dimensions (2)

(1) Methods specified in Technical Document 1, Part 2.

(2) 1 specimen corresponding to as many fittings (cavities) as the mould used contains.

A campaign corresponds to the period between the start of manufacturing of a product reference number and the

switch to the next number.

3.2 QUALITY MANAGEMENT OPTION

The implemented quality assurance plan must enable product compliance with the specifications of the standards

and of this regulation.

Consequently, the manufacturer must complete or ensure completion of the specified tests per the frequencies

defined in the quality assurance plan, certain tests being able to be considered "type" tests (for putting new

equipment in place or using a new formulation, for example).

The dimensional quality control testing carried out on the same fittings from TD2 of this reference system are

deemed to satisfy the dimensional verifications of this reference system.

Page 21: RIGID NON-PLASTICISED PVC PIPES AND FITTINGS ......The reference specifications and test methods for the NF Mark Rigid Non-Plasticised PVC Pipes and Fittings are defined in the tables

Technical document 055-06 rev 00 – page 21/24

Part 4. MONITORING ARRANGEMENTS BY CSTB

4.1 TEST PROCEDURES DURING AN APPLICATION FOR ADMISSION

For pipes in the Discharge family – Solid-Wall PVC pipes for rainwater intended for siphonic systems:

TABLE 8

Measurement or test Tests conducted in the factory Tests conducted in the

laboratory

Average external diameter*

Appearance

Marking

Colour

Length

Any diameter

Thickness

Sockets (depth of groove)

All the types submitted for

admission -

Density (1) 1 test (choice of type and

category) 1 test

Vicat softening temperature (1) 1 test (choice of type and

category) 1 test

Tensile characteristics (maximum stress and

elongation at break) (1)

1 test (choice of category),

except in the case where this test

is a type test

1 test per type sampled

Reversion at 150°C (1) 1 test (choice of category) 1 test per type sampled

Impact resistance (1) NF EN 744 1 test 1 test per type sampled

(1) With additional clarifications indicated in Technical Document 1, Part 2.

(*) Case of manufacturers holding the NF Mark TD2: the range admitted in TD6 being geometrically identical to the

range admitted in TD2, inspection of dimensions will not be performed. Only the TD6 range not matching TD2

will be inspected; this TD6 range is distinguished by angles and Z- and H-lengths different from those of TD2. A

list of this range shall be made available in the factories during an audit by the certification body.

Page 22: RIGID NON-PLASTICISED PVC PIPES AND FITTINGS ......The reference specifications and test methods for the NF Mark Rigid Non-Plasticised PVC Pipes and Fittings are defined in the tables

Technical document 055-06 rev 00 – page 22/24

For fittings in the Discharge family – Solid-Wall PVC fittings for rainwater intended for siphonic

systems:

TABLE 9

Measurement or test Tests conducted in the factory Tests conducted in the

laboratory

Average external diameter**

Appearance

Marking

Colour

Thickness

Assembly dimension

Sockets

All the types submitted for

admission: by dimensional

inspection of stock on at least half

the range presented and by

verification of the inspection

registers for the entire range

-

Vicat softening temperature (1) 1 test 1 test

Density (1) 1 test 1 test

Oven test at 150°C (1) 1 test per fitting sampled (*) 1 test per fitting sampled (*)

Leaktightness under negative pressure - 1 test on 1 expansion sleeve

Quality of elastomer sealing rings -

1 report of tests provided by the

manufacturer of elastomer sealing

rings.

(1) With additional clarifications indicated in Technical Document 1, Part 2.

(*): Limited to 4 fittings.

(**) Case of manufacturers holding the NF Mark TD2: the range admitted in TD6 being geometrically identical to the range

admitted in TD2, inspection of dimensions will not be performed. Only the TD6 range not matching TD2 will be inspected;

this TD6 range is distinguished by angles and Z- and H-lengths different from those of TD2. A list of this range shall be

made available in the factories during an audit by the certification body.

Page 23: RIGID NON-PLASTICISED PVC PIPES AND FITTINGS ......The reference specifications and test methods for the NF Mark Rigid Non-Plasticised PVC Pipes and Fittings are defined in the tables

Technical document 055-06 rev 00 – page 23/24

4.2 TEST PROCEDURES DURING MONITORING OF CERTIFIED

PRODUCTS

For pipes in the Discharge family – Solid-Wall PVC pipes for rainwater intended for siphonic systems:

TABLE 10

Measurement or test

Tests conducted in the factory Tests conducted in the

laboratory Quality control Quality management

Average external diameter

Appearance

Marking

Colour

Length

Any diameter

Thickness

Sockets (depth of groove)

5 types per visit divided between each family admitted

and product category -

Density (1) Inspection of test records 1 type per year

Vicat softening temperature (1) Inspection of test records 1 type per year

Tensile characteristics (maximum

stress and elongation at break) (1) Inspection of test records 1 type per year

Reversion at 150°C (1) 1 type at each visit

(choice of category)

1 type per year (choice of

category) 1 type per year

Impact resistance (1) NF EN 744 1 type at each visit

(choice of category)

1 type per year (choice of

category) 1 type per year

(1) With additional clarifications indicated in Technical Document 1, Part 2.

Page 24: RIGID NON-PLASTICISED PVC PIPES AND FITTINGS ......The reference specifications and test methods for the NF Mark Rigid Non-Plasticised PVC Pipes and Fittings are defined in the tables

Technical document 055-06 rev 00 – page 24/24

For fittings in the Discharge family – Solid-Wall PVC fittings for rainwater intended for siphonic

systems:

TABLE 11

Measurement or test

Quality control

Quality management

Quality control Quality management

Appearance (2)

Marking

Colour

Average external diameter

Any diameter

Thickness of the fitting’s body

3 diameters per visit and per category (choice of type) -

Sockets 3 diameters per visit and per category (choice of type) -

Vicat softening temperature (1) Inspection of test records 1 diameter per year

Density (1) Inspection of test records 1 diameter per year

Oven test at 150°C (1)

3 diameters per visit

(choice of type and

category)

3 diameters per year

(choice of type and

category)

1 diameter per year

Leaktightness under negative

pressure - - 1 test on 1 expansion sleeve

(1) With additional clarifications indicated in Technical Document 1, Part 2.

(2) Case of manufacturers holding the NF Mark TD2: the range admitted in TD6 being geometrically identical to the

range admitted in TD2, inspection of dimensions will not be performed. Only the TD6 range not matching TD2

will be inspected; this TD6 range is distinguished by angles and Z- and H-lengths different from those of TD2. A

list of this range shall be made available in the factories during an audit by the certification body.