8/7/2019 Ribbon Minder
http://slidepdf.com/reader/full/ribbon-minder 2/5
RibbonMinder O
peration
232
the selections
at that level. Pressing the ENTER
key selects an item and the system
inserts an asterisk ( * ) to indicate
that this
is now the de
fault option.
Ribbon En
d Point
Factory defau
lt is Normal. This value correspond
s to the character life expectancy o
f the detected, authorized ribbon in
stalled in
the printer. RibbonMinder tracks ribbon life to the recommended end point before d
eclaring 301 RIBBON INK LOW or 146
RIBBON INK OUT. This is a global setting: it is in effect for all printer configurations and cannot be set for individual p
rinter
configurations.
To change this setting, press the SCROLL↓ or SCROLL↑ key to select “Darker +1” through “Darker +6” (SCROLL↓) or “Lighter
-1” through “L
ighter -10” (SCROLL↑), where eac
h increment or decrement corresponds to a predetermined set value (density).
Pressing SCR
OLL↓ or RIGHT changes the valu
e by one increment per key press. The second line of the display cha
nges to
show the action taken. Press ENTER to select the desired level. The changed setting will remain in effect until it is ad
justed
NOT READ
Y
PRINTER CONTROL
PRINTER CON
TROL
Ribbon End Po
int
Interface S
election
Display Language
Print Direction
Hex Print M
ode
Power On State
Paper Jam
Detection
Forms Spe
ed
Set Platen at BOF
Shuttle Tim
eout
Energy Saver Timer
OCR Font Density
Eject/Resto
re
PTR Setup
Option
File System
Power Stacker
1
Auto Eleva
tor
1
Printer Management Port
Top Exit Te
ar Distance
Ribbon End Point
Ribbon Action
PRINTER CONTRO
L
Ribbon Action
Ribbon Action
Stop At RBN End*
Ribbon Action
Ignore RBN End
Ribbon End P
oint
Darker +1, +2, +3,
+4, +5, +6
Ribbon End Point
Normal*
Ribbon End Point
Lighter -1, -2, -3, -4,
-5, -6, -7, -8, -9, -10
1 If power stacker is
installed
8/7/2019 Ribbon Minder
http://slidepdf.com/reader/full/ribbon-minder 3/5
RibbonMinder O
peration
233
again. If a different type of ribbon is installed, the density setting will remain as sele
cted, but the end of life value for th
e new
ribbon type w
ill be used.
By changing this setting, you specify a point low
er or higher at which the “301 RIBB
ON INK LOW” or “146 RIBBON IN
K OUT”
message will display. The user can thus set ribb
on life to match the required print d
ensity for a specific application. The graph
below shows the relationship between print density and the Ribbon End Point settings.
For reference
, the nominal starting density of a new black text ribbon is approximately 1.2, with a yield to 0.5 density of
approximately 16 million HS characters. Incrementing the Darker setting will raise the density end point, while decreasing the
yield. Each D
arker increment will decrease the y
ield by a percentage from the expected 16 million. For example, Darker +1
would change
the expected yield to 12.67 million characters. Darker +3 would decrease the yield to 6 million characte
rs.
Conversely, d
ecrementing the Lighter setting de
creases the density, which increas
es the yield. Each Lighter decreme
nt
increases the
yield by an additional percentage. For example, Lighter -2 would cha
nge the expected yield to 30 million
characters. Lighter -5 would result in an approximate yield of 52 million characters.
Changes to this setting can be made at any time
during a ribbon’s life, and the new
end point will be calculated accordingly.
However, onc
e a depleted ribbon is removed and another ribbon installed, the deple
ted ribbon is added to the used ribbon long,
and may not be re-introduced into the printer.
Ribbon Ac
tion
Factory defau
lt is Stop At RBN End. When the ribbon life reaches 0%, the message “146 RIBBON INK OUT / INSTAL
L NEW
IBM RIBBON
” displays on the operator panel. The status lamp flashes, the alarm s
ounds (if enabled), printing stops, and the
printer enters
the fault state. Printing cannot resume until this condition is cleared. To complete a print job in progress, you can
return the printer to READY state by pressing START. This allows the printer to co
ntinue printing for approximately tw
o
1.2
0.8
0.5
0.2
+3+2+1
-1
-2
-3
-4
-5
Setting
Density
X Normal
8/7/2019 Ribbon Minder
http://slidepdf.com/reader/full/ribbon-minder 5/5
The Rib
bon Log
235
The Ribbo
n Log
The printer id
entifies each ribbon by maker, type
, and a unique identification code. RibbonMinder recognizes the currently
installed ribbo
n and previously used (but not dep
leted) ribbons, and resumes tracking the life of the ribbon from the value it had
when it was removed from the printer.
The printer ke
eps a log of the depleted ribbons, identifying them if they are again installed on the printer. This information is not
printed in detail, but a summary by type of all ribb
ons ever installed on a particular p
rinter is printed in the log for review
. The log
also captures
any attempts to run Unknown1 or Unknown2 ribbons. This informatio
n is recorded in the log as “Ribbon
Not
Recognized.”
The Ribbon Log is a permanent re
cord; it cannot be cleared. The loca
tion and format of the Ribbon Log is shown
below.
NOT REA
DY
OPERATOR PRINT TESTS
Printer De
monstration *
Print Erro
r Log
Print Ribb
on Log
Ripple Print
All E’s
All H’s
All E’s + F
F
Underline
s
Adapter T
est Page
1
Ethernet Test Page
1
Clear Error Log
1 Appears only if ethernet
NIC is ins
talled
Ribbon Log
Installed Ribbon = IBM, Ribbon Name, 55%, Normal
Ribbon History = IBM, Ribbon Name = 45
IBM, Ribbon Name2 = 33
IBM, Undefined = 2
Ribbon Not Recognized = 3