Section 1GLASSWOOL
Rhino glasswool batt insulation range
Section 2BLANKET
Rhino blanket range
Section 3POLYESTER
Rhino white polyester batt range
Section 4CELL RANGE
Rhino cell range
Section 5FOAM
Rhino foam range
Section 6WRAP & FOIL
Rhino wrap reflective foil range
Section 7PIR BOARD
Rhino PIR board range
Section 8ROCKWOOL
Other wall & surface insulation products
Section 9ACCESSORIES
by THOR BUILDING PRODUCTS
RHINO is a trusted brand in the building industry known for Quality Products, Service & Support.
Proudly Owned & Manufactured in Australia for 15 years
Section 1RHINO GLASSWOOL BATT INSULATION RANGE
• Rhino Batts
Rhino Wall & Celling Batts provide a thermal and acoustic barrier for energy-efficient construction.
• Rhino Partition Batts
Commercial acoustic and thermal insulation in steel stud framing for multi-residential and commercial steel frame buildings
• Rhino Partition Batts
Commercial acoustic and thermal insulation
by THOR BUILDING PRODUCTS
sttaB noititraP ONIHRCommercial acoustic and thermal insulation
Product description and typical applicationsRHINO Partition Batts is a lightweight, glasswool product specially designed to be free standing for quick installation in steel stud framing for multi-residential and commercial steel frame buildings. All products are designed to give assurance of effective sound absorption and to reduce noise transfer between rooms. Whilst effectively providing solutions to ‘problem’ acoustic applications, RHINO Partition Batts also provides a range of thermal values making the products suitable for insulating the external walls of a building envelope thereby increasing the comfort levels of building occupants.
rof leef retfos a sedivorp taht alumrof noitareneG txeN a serutaef sttaB noititraP ONIHRmore comfortable handling.
Physical characteristicsMaterial R-value
Nominal thickness
Batt size mm
Pieces per pack
Area per pack m2
Product code
R1.2 50
1200 x 450 32 17.32700 x 450 24 29.21200 x 600 32 25.02700 x 600 16 25.9
R1.8 75
1200 x 450 16 8.62700 x 450 24 29.21200 x 600 16 11.52700 x 600 16 25.9
R2.1 90
1200 x 450 16 8.62700 x 450 24 29.21200 x 600 16 11.52700 x 600 16 25.9
RPBatt-50-11-1245RPBatt-50-11-2745RPBatt-50-11-1260RPBatt-50-11-2760RPBatt-75-11-1245RPBatt-75-11-2745RPBatt-75-11-1260RPBatt-75-11-2760RPBatt-90-11-1245RPBatt-90-11-2745RPBatt-90-11-1260RPBatt-90-11-2760
R1.3 50
1200 x 450 24 13.02700 x 450 24 29.21200 x 600 24 17.32700 x 600 16 25.9
R1.9 75
1200 x 450 16 8.62700 x 450 18 21.91200 x 600 16 11.52700 x 600 12 19.4
R2.2 90
1200 x 450 14 7.62700 x 450 15 18.21200 x 600 10 7.22700 x 600 10 16.2
RPBatt-50-14-1245RPBatt-50-14-2745RPBatt-50-14-1260RPBatt-50-14-2760RPBatt-75-14-1245RPBatt-75-14-2745RPBatt-75-14-1260RPBatt-75-14-2760RPBatt-90-14-1245RPBatt-90-14-2745RPBatt-90-14-1260RPBatt-90-14-2760
R0.7 25 2700 x 600 20 32.40 RPBatt-25-24-2760R1.1 38 2700 x 600 12 19.40 RPBatt-38-24-2760
R1.4 501200 x 450 12 6.501200 x 600 12 8.602700 x 600 12 19.40 RPBatt-50-24-2760
R1.8 64 2700 x 600 10 16.20 RPBatt-64-24-2760
R2.1 751200 x 450 10 5.401200 x 600 10 7.20
R2.5 901200 x 450 8 4.301200 x 600 8 5.80
R2.8 1001200 x 450 6 3.201200 x 600 6 4.30
R1.5 501200 x 450 12 6.5 RPBatt-50-32-12451200 x 600 12 8.6 RPBatt-50-32-1260
R2.2 751200 x 450 10 5.4 RPBatt-75-32-12451200 x 600 10 7.2 RPBatt-75-32-1260
R2.7 901200 x 450 8 4.31200 x 600 8 5.8
R3.0 1001200 x 450 6 3.21200 x 600 6 4.3
Technical Data Sheet
AS/NZS 4859.1: 2002 - Including Amendment 1
Materials for the Thermal Insulation of Buildings
RHINO Partition Battsproducts comply with the
Energy Efficiency provisions of the BCA for all types of thermal insulation to be certified by a
NATA accredited organisation.
NEXTGENERATION
FORMULA
With a softer feel for more
comfortablehandling
RHINO Partition 12 Insulation
RHINO Partition 14 Insulation
RHINO Partition 24 Insulation
RHINO Partition 32 Insulation
Technical Data Sheet
Acoustic performance predictions
1
2
3
4
7
5
6
7
5
6
1
3
4
2
4
2
3
1
1. 7.5mm (R0.1) lightweight cladding2. Unventilated 35mm airspace3. Reflective insulation material4. 35mm battens5. 90mm RHINO a Partition 24 insul tion6. 92mm steel stud7. 10mm plasterboard
1. Steel cladding2. Unventilated 35mm airspace3. Reflective insulation material4. 35mm battens5. 90mm RHINO Partition 32 insulation6. 92mm steel stud7. 10mm plasterboard
1. 10mm plasterboard2. 92mm steel stud3. 90mm RHINO Partition 14 Insulation4. 10mm Plasterboard
Sound Reduction Index (Rw) 48The Rw estimated tolerance is +/- 3dB.
Sound Reduction Index (Rw) 41 The Rw estimated tolerance is +/- 3dB.
Sound Reduction Index (Rw) 42 The Rw estimated tolerance is +/- 3dB.
FIBRE CEMENT CLAD STEEL STUD WALL SYSTEM
METAL CLAD STEEL STUD WALL SYSTEM
INTERNAL STEEL FRAME PARTITION WALL
AS/NZS 4859.1: 2002 - Including Amendment 1
Materials for the Thermal Insulation of Buildings
RHINO Partition insulation products comply with the
Energy Efficiency provisions of the BCA for all types of thermal insulation to be certified by a
NATA accredited organisation.
NEXTGENERATION
FORMULA
With a softer feel for more
comfortablehandling
Technical Data Sheet
Installation guidelinesTOOLS REQUIRED:• Curved blade knife with plastic handle (non-conductive handle)• For high density batts a serrated knife with a plastic handle is recommended• Knife holster to quickly access the knife• Industrial strength ladder• Tape measure• Safety eye wear• Safety shoes
BEFORE YOU COMMENCE: Turn off the power at the fuse box before commencing the installation. Ensure you place a warning tag to prevent power being restored prior to completion of the install. Be aware that your electrical appliances will not be operational during this time. Use only RHINO Partition insulation, recommended according to the type and thickness of the stud.
BRICK VENEER:•
and studs or noggins. tcatnoc ni emoc ro ytivac eht otni llaf tonnac ti os deruces si noitalusni eht taht tnatropmi si tI •
with the outer brickwork allowing moisture to pass from the exterior wall to the internal lining.•
installing the insulation from the inside.• et of studs from the top to the
bottom, running parallel with the studs. Where two lengths are used they should be evenly spaced.•
around water pipes or other rigid obstructions in the wall. FIBRE CEMENT OR WEATHERBOARD CLADDING:
esuac ot ton sa os desu eb tsum repap gnidliub ro parw llaw )reirrab ruopav wol( rehtaerb A •moisture build up.
• Butt the insulation closely together to ensure there are no gaps left at joints.
CAVITY BRICK WALLS (DOUBLE BRICK): • RHINO Partition insulation is not recommended for use in cavity brick construction.
INTERNAL PARTITION WALLS:•
and studs or noggins.•
For comprehensive details, please refer to Australian Standard 3999.
CAUTION: Electric cables and equipment partially or completely surrounded with bulk thermal insulation may overheat and fail. This applies to wiring installed prior to 1989. Refer to AS3999-1992 including Amendment 1: Section 2.6 for details. Cabling post 1989: continuous electrical cabling (240 volts) cannot be fully surrounded by the insulation for a length greater than 300mm. In runs greater than 300mm, the electrical wiring must be touching a timber stud or the plaster lining.
Green Star compliantRHINO Partition Insulation does not use Ozone Depleting Potential (ODP) substances in the
® and Sisalation® reflective foil manufacture or composition of its FBS-1 Glass Wool Bio-Soluble Insulationproducts using insulation with an ODP of zero will accrue one Green Star point under the Insulant ODP Credit for eligible Green Star projects.
The use of these RHINO Partition Insulation products guarantees the use of ODP free insulation while also ensuring that no harmful levels of Volatile Organic Compounds (VOCs) are released. This allows the incorporation of environmentally preferable insulation whilst also maintaining indoor air quality.
AS/NZS 4859.1: 2002 - Including Amendment 1
Materials for the Thermal Insulation of Buildings
RHINO Partition insulation products comply with the
Energy Efficiency provisions of the BCA for all types of thermal insulation to be certified by a
NATA accredited organisation.
NEXTGENERATION
FORMULA
With asofter feelfor more
comfortable handling
Technical Data Sheet
AS 1530.1-1994 Test for combustibility of materialsTesting conducted by CSIRO in accordance with AS1530.1concluded that all 11-32kg/m3 RHINO Partition insulation products are non-combustible.
The National Construction Code (NCC) deemed to satisfy provisions require walls important to the structural integrity of commercial buildings to be constructed wholly of materials that are non-combustible. Fire rated walls between tenancies and common walls of multi-level apartment buildings must also be constructed wholly of materials that are non-combustible. The NCC states that if materials used in an assembly contain combustible components, then the assembly is combustible. Therefore incorporating non-combustible RHINO Partition insulation into wall systems allows users to obtain the products thermal and acoustic benefits whilst complying with the NCC requirement to maintain a buildings structural integrity.
AS/NZS 1530.3-1999 Early fire hazard properties of materials RHINO Partition insulation exhibits the following characteristics when tested in accordance with AS1530.3.
Ignitability Index 0
Spread of Flame Index 0
Heat Evolved Index 0
Smoke Developed Index 0-1
Moisture Absorption In the event of RHINO Partition Batts becoming wet, it should be dried prior to installation to obtain maximum performance and prevent damage to other building elements. RHINO Partition insulation absorbs less than 0.2% moisture by volume when exposed to environmental conditions of 50˚C and 95% relative humidity for four days.
AlkalinityWhen tested in accordance with British Standard 3958, Fletcher Insulation™ glasswool products are slightly alkaline ph9 (neutral is ph7). They will not promote or accelerate the corrosion of steel or galvanised steel studs provided they are protected from external contamination.
Maximum Service TemperatureRHINO Partition Batts have a maximum service temperature of 340˚C.
Specification notesState the following:• Product name i.e. RHINO Partition Batts followed by the relevant density i.e. RHINO Partition
11, 14, 24 or 32.• Material R-value required and/or thickness required• Joist or stud spacing• Area involved
AS/NZS 4859.1: 2002 - Including Amendment 1
Materials for the Thermal Insulation of Buildings
RHINO Partition insulation products comply with the
Energy Efficiency provisions of the BCA for all types of thermal insulation to be certified by a
NATA accredited organisation.
NEXTGENERATION
FORMULA
With a softer feel for more
comfortablehandling
Thor Building Products P/L
293 Earnshaw Road - Northgate QLD 4013
www.thorbuilding.com.au
PH 1300 880 828
RHINO PARTITION BATTS
RHINO Partition Batts - Data Sheet:
RHINO Partition Batts are a lightweight, glasswool
product specially designed to be free standing for quick
installation in steel stud framing for multi-residential
and commercial steel frame buildings.
Commercial acoustic and thermal insulation
Product description and typical applications
RHINO Partition Batts is a lightweight, glasswool product specially designed to be free standing
for quick installation in steel stud framing for multi-residential and commercial steel frame
buildings. All products are designed to give assurance of effective sound absorption and to
reduce noise transfer between rooms. Whilst effectively providing solutions to ‘problem’ acoustic
applications, RHINO Partition Batts also provides a range of thermal values making the products
suitable for insulating the external walls of a building envelope thereby increasing the comfort
levels of building occupants.
RHINO Partition Batts features a soft feel for more comfortable handling.
23.1
Acoustic performance predictions
1. 7.5mm (R0.1) lightweight cladding2. Unventilated 35mm airspace3. Reflective insulation material4. 35mm battens5. 90mm RHINO Partition 24 insulation6. 92mm steel stud7. 10mm plasterboard
Sound Reduction Index
(Rw) 48The Rw estimated tolerance is +/- 3dB.
METAL CLAD STEEL STUD WALL SYSTEM
1. Steel cladding
2. Unventilated 35mm airspace
3. Reflective insulation material
4. 35mm battens
5. 90mm RHINO Partition 32 insulation
6. 92mm steel stud
7. 10mm plasterboard
Sound Reduction Index
(Rw) 41The Rw estimated tolerance is +/- 3dB.
INTERNAL STEEL FRAME PARTITION WALL
1. 10mm plasterboard
2. 92mm steel stud
3. 90mm RHINO Partition 14 Insulation
4. 10mm Plasterboard
Sound Reduction Index
(Rw) 42The Rw estimated tolerance is +/- 3dB
RHINO PARTITION BATTS
FIBRE CEMENT CLAD STEEL STUD WALL SYSTEM
Data Sheet
Data Sheet
Installation guidelines
TOOLS REQUIRED:• Curved blade knife with plastic handle
(non-conductive handle)• For high density batts a serrated knife with a plastic handle is
recommended• Knife holster to quickly access the knife
• Industrial strength ladder• Tape measure
• Safety eye wear• Safety shoes
BEFORE YOU COMMENCE: Turn off the power at the fuse box before commencing the installation.
Ensure you place a warning tag to prevent power being restored prior to completionof the install. Be aware that your electrical appliances will not be operational during this time.
Use only RHINO Partition insulation, recommended according to the type and thickness of the stud.
BRICK VENEER:• Friction fit the Insulation into the wall frames ensuring there are no gaps between the insulation and
studs or noggins.• It is important that the insulation is secured so it cannot fall into the cavity or come in contact with the
outer brickwork allowing moisture to pass from the exterior wall to the internal lining.• Wall wrap or long lasting string/twine should be fixed across the exterior face of the frame before installing
the insulation from the inside.Where string/twine is used, twine should be fixed between each set of studs from the top to the bottom,
running parallel with the studs. Where two lengths are used they should be evenly spaced. •Ensure that the batts do not protrude past the stud and fit snugly including where insulation is around water pipes or
other rigid obstructions in the wall.
FIBRE CEMENT OR WEATHERBOARD CLADDING:• A breather (low vapour barrier) wall wrap or building paper must be used so as not to cause moisture build up.
• Butt the insulation closely together to ensure there are no gaps left at joints.• Offcuts may be used to fill small spaces to ensure complete coverage.
CAVITY BRICK WALLS (DOUBLE BRICK):• RHINO Partition insulation is not recommended for use in cavity brick construction.
INTERNAL PARTITION WALLS:• Friction fit the Insulation into the wall frames ensuring there are no gaps between the insulation and studs or noggins.
• Ensure that the batts do not protrude past the stud and fit snugly
For comprehensive details, please refer to Australian Standard 3999. CAUTION: Electric cables and equipment partially or completely surrounded with bulk thermal insulation may overheat and fail.
This applies to wiring installed prior to 1989. Refer to AS39991992 including Amendment 1: Section 2.6 for details. Cabling post 1989: continuous electrical cabling (240 volts) cannot be fully surrounded by the insulation for a length greater than
300mm. In runs greater than 300mm, the electrical wiring must be touching a timber stud or the plaster lining.
Green Star compliant: RHINO Partition Insulation does not use Ozone Depleting Potential (ODP) substances in themanufacture or composition of its FBS-1 Glass Wool Bio-Soluble Insulation ® and Sisalation® reflective foil products using
insulation with an ODP of zero will accrue one Green Star point under the Insulant ODP Credit for eligible Green Star projects.
The use of these RHINO Partition Insulation products guarantees the use of ODP free insulation while also ensuring that no harmful levels of Volatile Organic Compounds (VOCs) are released. This allows the incorporation of environmentally preferable
insulation whilst also maintaining indoor air quality.
Data Sheet AS 1530.1-1994Test for combustibility of materials
Testing conducted by CSIRO in accordance with AS1530.1 concluded
that all 11-32kg/m3 RHINO Partition insulation products are non-combustible.
The National Construction Code (NCC) deemed to satisfy provisions require walls
important to the structural integrity of commercial buildings to be constructed wholly
of materials that arenon-combustible. Fire rated walls between tenancies and common
walls of multi-level apartment buildings must also be constructed wholly of materials that
are non-combustible. The NCC states that if materials used in an assembly contain combustible
components, then the assembly is combustible. Therefore incorporating non-combustible RHINO
Partition insulation into wall systems allows users to obtain the products thermal and acoustic benefits
whilst complying with the NCC requirement to maintain a buildings structural integrity.
AS/NZS 1530.3-1999 Early fire hazard properties of materialsRHINO Partition insulation exhibits the following characteristics when tested in accordance with AS1530.3.
Ignitability Index 0
Spread of Flame Index 0
Heat Evolved Index 0
Smoke Developed Index 0-1
Moisture Absorption
In the event of RHINO Partition Batts becoming wet, it should be dried prior to installation to obtain maximum performance and
prevent damage to other building elements. RHINO Partition insulation absorbs less than 0.2% moisture by volume when exposed
to environmental conditions of 50˚C and 95% relative humidity for four days.
Alkalinity
When tested in accordance with British Standard 3958, Fletcher Insulation™ glasswool products are slightly alkaline ph9 (neutral is ph7).
They will not promote or accelerate the corrosion of steel or galvanised steel studs provided they are protected from external
contamination.
Maximum Service TemperatureRHINO Partition Batts have a maximum service temperature of 340˚C.
Specification notesState the following:
• Product name i.e. RHINO Partition Batts followed by the relevant density i.e. RHINO Partition
11, 14, 24 or 32.• Material R-value required and/or thickness required
• Joist or stud spacing
• Area involved
Thor Building Products P/L
293 Earnshaw Road - Northgate QLD 4013
PH 1300 880 828
www.thorbuilding.com .au
Section 2RHINO BLANKET INSULATION RANGE
• Rhino Blanket
Reflective foil laminate blanket intended for both thermal and acoustical applications
• Rhino Facing Foil
Rhino Blanket Facing reflective foil face faces down toward the air space under the roof and prevents airborne moisture from reaching the surface of the roof cladding, made with a high strength polywoven fabric facing which is applied to a glasswool blanket.
by THOR BUILDING PRODUCTS
M a nu fac tu re d b y
Excellent thermal & acoustic insulation Highly resilient insulation
Can be used with timber & metal frame Consistent quality
Superior finished aesthetics AS/NZS 4859.1:2002
Cost-effective Bio-soluble
Non-combustible blanket fibres BCA Compliant
TRADE preferred low VOC-emitting
Information Technology Solutions
THERMAL INSULATION WITH CONDENSATION
CONTROL
Rhino Blanket combines the thermal efficiency of spun
glass fibre with a laminate of reflective foil which not only
further enhances the thermal efficiency of the system but
also serves to act as a dust and moisture barrier.
Description
Rhino Blanket is intended for both thermal and
acoustical applications. It is made from highly resilient,
inorganic glass fibres.
Specification Compliance
AS/NZS 4859.1: 2002 Materials used in the
Thermal Insulation of Buildings and complies with the
Building Code of Australia (BCA) requirements.
Bio-Solubility
Rhino Blanket rolls are manufactured from bio-soluble
fibres. Bio-soluble fibres have been extensively
researched and shown to pose no long term health risk.
Application
Designed for application under metal, fibre cement, and
concrete roof cladding Rhino Blanket eliminates the
problems associated with condensation build up on the
underside of the roof cladding. The reflective foil face
faces down toward the air space under the roof and
prevents airborne moisture from reaching the surface of
the roof cladding.
Rhino Blanket also performs as an acoustic insulative
barrier. It reduces noise from outside the home, such as
rain and from within the home by absorbing reverberant
noise. Rhino Blanket’s bulk insulation blanket is made
from non-combustible fibres and meets the
BAL requirement for metal clad roofs in bushfire areas.
Facing Options
The Duty Rating, Colour and Material Finish used to face
Rhino Blanket can be varied to suit your application.
Details upon request.
PER FO RM AN CE
Thermal ConductivityASTM C 518AS/NZS 4859.1: 2002
Thermal ResistanceASTM C 653AS/NZS 4859.1: 2002
TE CH N ICA L DA TA
Water Vapor Absorption(ASTM C 1104)Less than 5% by weight
Corrosion Resistance(ASTM C 665)No greater than sterile cotton
Microbial Growth (ASTMC 1338)Does not support microbial growth
Fire Resistance(ASTM C 136)Non-combustible
Pro u d l y Ma n u fa c tu red b y
Thor Building Products P/L
Product Code Thickness R-Value Dimensions * Rolls m2
(mm) (m2 K/W) (mm) per pack per pack
RB-R1.3-55 55 1.3 1200 x 15000 1 18
RB-R1.5-60 60 1.5 1200 x 15000 1 18
RB-R1.8-75 75 1.8 1200 x 15000 1 18
RB-R2.3-100 100 2.3 1200 x 10000 1 12
RB-R2.5-100 100 2.5 1200 x 10000 1 12
RB-R3.0-130 130 3.0 1200 x 10000 1 12
RB-R3.2-130 130 3.2 1200 x 10000 1 12
RB-R3.6-130 130 3.6 1200 x 6500 1 7.8
RHINO BLANKET
1300 880 828
(07) 3219 6833
293 EARNSHAW ROADPO BOX 14NORTHGATE QLD 4013
WWW.THORBUILDING.COM.AU
FOIL FACED:
Other Thor Brands:
* Cut to size available on request
Product Code Thickness R-Value Dimensions Rolls m2
(mm) (m2 K/W) (mm) per pack per pack
URB-R1.3-36 55 1.3 1200 x 30000 1 36.00
URB-R1.5-36 60 1.5 1200 x 30000 1 36.00
URB-R1.8-30 75 1.8 1200 x 25000 1 30.00
URB-R2.3-18 100 2.3 1200 x 15000 1 18.00
URB-R2.5-18 100 2.5 1200 x 15000 1 18.00
URB-R3.0-12 130 3.0 1200 x 10000 1 12.00
URB-R3.2-12 130 3.2 1200 x 10000 1 12.00
URB-R3.6-78 130 3.6 1200 x 6500 1 7.8
UNFACED:
TOTALLY AUSTRALIAN OWNEDMANUFACTURED IN AUSTRALIA
FROM LOCAL & IMPORTEDCOMPONENTS
RHINO BLANKET FACING(HEAVY & EXTRA HEAVY DUTY)
PRODUCT INFORMATION
Thor’s Blanket Facing is made with a high strength polywoven fabric facing which is applied to a glasswool blanket whilst other products commonly use a double sided foil with fibre mesh for the facing.
The polywoven fabric provides the additional benefits of:
outstanding tensile and tear strength
unrolls more easily right the way to the end of the roll
an excellent visible surface finish
APPLICATIONDesigned for application under metal, fibre cement, and concrete roof cladding Thor’s Blanket Facing eliminates the problems associated with condensation build up on the underside of the roof cladding. The reflective foil face faces down toward the air space under the roof and prevents airborne moisture from reaching the surface of the roof cladding.
NOTE: Use in cold temperature climates (daytime <5oC) requires roof to be well ventilated and moist air from within the dwelling to be exhausted out into the atmosphere.
FACING OPTIONS
The Duty Rating, Colour and Material Finish of the blanket facing can be varied to suit your application.
Colour Gloss White
Gloss Silver-Grey
Matt Dark Blue
Duty Extra Heavy Heavy Heavy
Width 1350 1350 1350
Residential & Commercial Insulation
Vapour barrier High High High
Emittance Reflective Reflective Reflective
Water barrier High High High
Flammability Index Low (≤5) Low (≤5) Low (≤5)
UV treated non reflective face (not direct sunlight)
Tensile Strength Machine Direction (kN/m) min 13.0 min 12.5 min 12.5
Tensile Strength Lateral Direction (kN/m) min 10.5 min 7.5 min 7.5
Edge Tear Resistance Machine Direction (N) min 90 min 80 min 80
Edge Tear Resistance Lateral Directions (N) min 90 min 80 min 80
Water Vapour Transmission Rate (Ng/Ns) max 2 max 2 max 2
Emittance of Reflective Face max 0.05 max 0.05 max 0.05
Proudly Manufactured by
Thor Building Products P/L
1300 880 828(07) 3219 6833
293 EARNSHAW ROADPO BOX 14
NORTHGATE QLD 4013
WWW.THORBUILDING.COM.AU
Satisfy BCA specifications and requirements for Reflective Foil Laminates
Complies with the specifications and requirements of AS/NZS 4200.1 for "Pliable Building Membranes" which is a manual recognised by the BCA Part 3.5 Roof and Cladding
Low Flammability Index in accordance with AS 1530.2 ≤ 5
Satisfy BCA Part 3.7.1 Fire Hazard Properties
Satisfy Health and Safety Regulations
Section 3POLYESTER
• Rhino White
Wall & Ceiling Batts for thermal applications - 100% Polyester segments pre-cut to fit.
• Rhino White
Sound Batts and Rolls - 100% Polyester designed for timber framed residential and light commercial applications.
• Rhino Partition & Acoustic Blanket
Partition and Acoustic Blankets can be used in metal and timber stud partition walls as an acoustic ceiling overlay for reducing airborne sound transfer
• Rhino White
Sound Baffle for Acoustic Applications - 100% Polyester designed to be layer stacked above partition walls.
by THOR BUILDING PRODUCTS
BATTS
BATTS
are
BATTS are
RHINO WHITE Polyester is non hazardous.
WHITE BATTS
WHITE is
RHINO WHITE Polyester has been tested and certified non-flammable and complies with the requirements of IEC 60695-11-5. Certificates available from our website. Non Corrosive: RHINO WHITE polyester is pH7.8 (pH7 is neutral) Non Toxic, Non Allergenic, Non Irritant: There are no known hazards with the use or handling of RHINO WHITE polyester. Vermin: RHINO WHITE polyester is naturally resistant to insect and vermin attack.
Building Regulations: RHINO WHITE Insulation will support and
Thermal Performance: RHINO WHITE Insulation
Durability: RHINO WHITE Insulation has a 50 Year Durability Warranty. RHINO WHITE thermal insulation when installed in accordance with the manufacturer's instructions will satisfy the 50 year durability criteria for minimum design life as set out in the ABCB guidance document Durability in Buildings 2006 (Section 2.4).
back to recycle, uncontaminated RHINO WHITE insulation to help keep it out of landfill. For more information on recycling RHINO WHITE contact THOR on freephone 1300 880 828.
WHITE
haveRHINO WHITE, contact THOR BUILDING PRODUCTS on 1300 880 828.
Partition & Acoustic BlanketsAcoustic
fo the installer and building occupiers. Supplied in roll form to allow fast and efficient use and minimise waste. RHINO
WRA Blanket-50-610WRA Blanket-50-450
WRA Blanket-60-610WRA Blanket-60-450
WRA Blanket-70-610WRA Blanket-70-450
WRA Blanket-80-610WRA Blanket-80-450
WRA Blanket-90-610WRA Blanket-90-450
WRA Blanket-40-610WRA Blanket-40-450 4
RHINO WHITE COMMERCIAL PARTITION BLANKET is supplied standard in either 11 or 14kgm3 and ranged in
to match the product thickness as closely as possible to the stud depth. RHINO WHITE COMMERCIAL PARTITION
labour costs. Being 100% polyester it is non toxic and completely safe for the installer and building occupiers.
WRP Blanket-50-610-11
WRP Blanket-50-450-11
WRP Blanket-75-610-11
WRP Blanket-75-450-11
WRP Blanket-50-610-14
WRP Blanket-50-450-14
WRP Blanket-75-610-14
WRP Blanket-75-450-14
WRP Blanket-90-610-14
WRP Blanket-90-450-14
performance of partition wall and ceiling systems. RHINO WHITE PERFORMANCE INFILL improves the acoustic separation by reducing noise intrusion and increasing sound privacy between spaces. HPI should be used where optimal acoustic performance is required. Manufactured from 100% polyester RHINO WHITE PERFORMANCE INFILL is completely safe for installer and building occupiers and has no known health hazards.
WRH Infill-60-610WRH Infill-60-450
WRH Infill-90-610WRH Infill-90-450
WRH Infill-165-610WRH Infill-165-450
AcousticWHITE Sound Blanket
WHITE
low temperatures and extended periods ofstorage in compressed packaging. Installing product at less than
WRA Blanket-60
WRA Blanket-70
WRH Infill-60
WRA Blanket-60
WRA Blanket-70
WRH Infill-60
WRA Blanket-60
WRP Blanket-90-14
WRH Infill-90
WRA Blanket-70
WRP Blanket-75-11
WRH Infill-90
WRA Blanket-80
WRP Blanket-90-14
WRH Infill-90
WRA Blanket-70
WRP Blanket-75-11
WRP Blanket-75-14
WRH Infill-165
WRP Blanket-60
The Green Building Council of Australia (GBCA) has developed assessment tools to
contribute to points available in the various tools as set out in the table below.
helping keep it out of landfill. Please contact your THOR Account Manager for further details.
Green Star Materials credits aim to improve the environmental impacts of building products andmaterials. RHINO WHITE will assist in achieving the available credits in the applicable calculators. RHINO has a 50+year durability warranty, high recycled content and manufactured to
RHINO WHITE INSULATION RANGE has been independently tested and is well below the allowable
Acoustic
WHITE SOUND BAFFLE
WHITE SOUND BAFFLE
WHITE SOUND BAFFLE
RHINO WHITE SOUND BAFFLE is designed for use above new or
RHINO WHITE SOUND BAFFLE is a 100% polyester
RHINO WHITE SOUND BAFFLE must be installed with at least
the stack.RHINO WHITE SOUND BAFFLE can be installed to a height
WRB Block-100-600
WHITE
WHITE
WHITE
WHITE
should be installed as a layer stack above
WHITE has been engineered to supply a
RHINO WHITE contact THOR BUILDING
WHITE SOUND BAFFLE
Section 4RHINO CELL INSULATION RANGE
• Rhino Cell 104
3 in 1 insulation, vapour-barrier and radiant heat barrier for use in roof, wall and floor systems
• Rhino Cell 310
3 in 1 insulation, vapour-barrier and radiant heat barrier for use in roof, wall and floor systems
• Rhino Shed
3 in 1 insulation, vapour-barrier and radiant heat barrier for use in shed walls / under-roof systems where anti-glare is not requested
• Rhino Cell Cavity Wall
3 in 1 insulation, vapour-permeable and radiant heat barrier for use in wall systems
• Rhino Cell Underfloor
3 in 1 insulation, vapour-permeable and radiant heat barrier for use in underfloor systems
by THOR BUILDING PRODUCTS
Finished Product PerformanceCompliance to AS 4859.1 &AS4200.1
TEST DESCRIPTION PARAMETERASTM E - 408 Emissivity reflective face = 0.03 ± 0.01
antiglare face = 0.05 ± 0.01AS/NZS 4859.1 App – I Surface Corrosion PassAS/NZS 4859.1 App – H Corrosiveness Pass
ASTM 1530.2 Flammability Low (index ≤ 5)
ASTM 1530.3 Early Fire Hazard
Ignitability index - N/ASpread of Flame - ≤ 9Heat Evolved Ind. - N/A
Smoke developed Ind. - ≤ 5AS/NZS 3837 Cone Calorimeter BCA Classification 1AS 1301.448 Duty Rating, Tensile Strength EXTRA HEAVYTAPPI T470 Duty Rating, Edge Tear Resistance EXTRA HEAVY
AS 2001.2.19 Bursting Strength StatedAS 4201.1 Resistance to Dry Delamination PassAS 4201.2 Resistance to Wet Delamination PassAS 4201.3 Shrinkage ≤ 5%AS 4201.4 Water Barrier HighAS 4201.6 Absorbency UnclassifiedASTM E-96 Vapour Transmission Medium
Information Technology Solutions
Product Code Description Thickness R-Value Dimensions (m) m2 per pack(mm) (m2 K/W)
30
ManufacturingProcess::
Application Heat Flow In Heat Flow OutWarehouse metal roof retrofit, fully sealed R-3.0 R-0.8Floor, suspended timber enclosed sub floor R-3.1 R-1.6Commercial office metal roof, with ceiling R-3.5 R-1.2Residential Pitched Metal roof 22°, ventilated R-2.5 R-1.1Brick veneer wall R-1.9 R-2.1
Thermal Performance
R values shown are Total R values for the building element calculated by a chartered professional engineer and verified bya recognised laboratory. Total R values of the above systems for winter and summer conditions have been determined inaccordance with the requirements of AS/NZS4859.1:2002 Amdt 1 (2006), App K.
The contribution of this product total R-value depends on installation and environmental conditions. The R-value will bereduced in the event of the accumulation of dust on upward facing surfaces and in those cavities that are ventilated.
Product DescriptionRhino Cell 104 is a 3 in 1 insulation, vapour barrier and radiant heat barrier for use in roof, wall and floor systems.The fibre-free, non-allergenic, formaldehyde free materials used in Rhino Cell provide a safe solution which is also easy to install.Rhino Cell is strong, durable, has low flammability index (≤5) and is both rodent and insect resistant.
Available in Blue Antiglare surface finish.
Al Foil BUBBLE COMPOSITION:
Polyethylene
LAMINATE 2: Polyethylene weave Al Foil
Rhino Cell 104 AG
Proudly Manufactured by
Thor Building Products P/L
1300 880 828(07) 3219 6833
293 EARNSHAW ROADPO BOX 14
NORTHGATE QLD 4013
WWW.THORBUILDING.COM.AU
Product Specification WIDTH: 1.35m(+0.15m flap) LENGTH: 22.25m AREA: 30m2 THICKNESS: 4mm ± 1mm LAMINATE 1: Polyethylene weave
RC-104 AG Rhino Cell Antiglare 4mm R-0.10 1.35 (+0.15m flap) x 22.25(pack 0.32 dia. x 1.5)(pack mass 11.5kg)
M anu fac tu red by
Finished Product PerformanceCompliance to AS 4859.1 &AS4200.1
TEST DESCRIPTION PARAMETER
ASTM E - 408 Emissivity reflective face = 0.03 ± 0.01antiglare face = 0.05 ± 0.01
AS/NZS 4859.1 App - I Surface Corrosion PassAS/NZS 4859.1 App - H Corrosiveness PassASTM 1530.2 Flammability Low (index≤ 5)
ASTM 1530.3 Early Fire Hazard
Ignitability index - N/ASpread of Flame - ≤ 9Heat Evolved Ind. - N/A
Smoke developed Ind. - ≤ 5AS/NZS 3837 Cone Calorimeter BCA Classification 1AS 1301.448 Duty Rating, Tensile Strength EXTRA HEAVYTAPPI T470 Duty Rating, Edge Tear Resistance EXTRA HEAVYAS 2001.2.19 Bursting Strength StatedAS 4201.1 Resistance to Dry Delamination PassAS 4201.2 Resistance to Wet Delamination PassAS 4201.3 Shrinkage ≤ 5%AS 4201.4 Water Barrier HighAS 4201.6 Absorbency UnclassifiedASTM E-96 Vapour Transmission Medium
Information Technology Solutions
Product Code Description Thickness R-Value Dimensions (m) m2 per pack(mm) (m2 K/W)
RC-310 AG Rhino Cell Antiglare 11mm R-0.201.35 x 22.25
(pack 0.49 dia. x 1.5)(pack mass 12.5kg)
30
ManufacturingProcess::
Thermal PerformanceApplication Heat Flow In Heat Flow OutWarehouse metal roof with ceiling 300mm, no vent R-3.6 R-1.3Residential metal pitched roof 22° steel frame, ventilated R-2.6 R-1.2Warehouse metal roof, no ceiling fully sealed R-2.1 R-1.0
FLAP FOR ADDEDCOVERAGE
R values shown are Total R values for the building element calculated by a chartered professional engineer and verified bya recognised laboratory. Total R values of the above systems for winter and summer conditions have been determined inaccordance with the requirements of AS/NZS4859.1:2002 Amdt 1 (2006), App K.
The contribution of this product total R-value depends on installation and environmental conditions. The R-value will bereduced in the event of the accumulation of dust on upward facing surfaces and in those cavities that are ventilated.
Rhino Cell 310 AG
Product Description
Rhino Cell 310 Thermal Break is a 3 in 1 insulation, vapour barrier and radiant heat barrier for use in roof, wall and floor systems.
The fibre-free, non-allergenic, formaldehyde free materials used in Rhino Cell provide a safe solution which is also easy to install.
Rhino Cell is strong, durable, has low flammability index (≤5) and achieves a Thermal Break of R-0.2.
Available in Blue Antiglare surface finish.
UNIQUE 150MM FLAP ELIMINATES
NEED FOR OVERLAP SAVING UP TO 10%
Product Specification WIDTH: 1.35m
(+0.15m Flap) LENGTH: 22.25m AREA: 30m2 coverage THICKNESS: 11mm LAMINATE 1: Polyethylene weave
Al Foil BUBBLE COMPOSITION:
Polyethylene
LAMINATE 2: Polyethylene weave Al Foil
Proudly Manufactured by
Thor Building Products P/L
1300 880 828(07) 3219 6833
293 EARNSHAW ROADPO BOX 14
NORTHGATE QLD 4013
WWW.THORBUILDING.COM.AU
Finished Product PerformanceCompliance to AS 4859.1 &AS4200.1
TEST DESCRIPTION PARAMETERASTM E - 408 Emissivity reflective face = 0.03 ± 0.01
AS/NZS 4859.1 App – I Surface Corrosion PassAS/NZS 4859.1 App – H Corrosiveness Pass
ASTM 1530.2 Flammability Low (index ≤ 5)
ASTM 1530.3 Early Fire Hazard
Ignitability index - N/ASpread of Flame - ≤ 9Heat Evolved Ind. - N/A
Smoke developed Ind. - ≤ 5AS/NZS 3837 Cone Calorimeter BCA Classification 1AS 1301.448 Duty Rating, Tensile Strength EXTRA HEAVYTAPPI T470 Duty Rating, Edge Tear Resistance EXTRA HEAVY
AS 2001.2.19 Bursting Strength StatedAS 4201.1 Resistance to Dry Delamination PassAS 4201.2 Resistance to Wet Delamination PassAS 4201.3 Shrinkage ≤ 5%AS 4201.4 Water Barrier HighAS 4201.6 Absorbency UnclassifiedASTM E-96 Vapour Transmission Medium
Information Technology Solutions
Product Code Description Thickness(mm)
R-Value(m2 K/W)
Dimensions (m) m2 per pack
RSHD Rhino Shed 4mm R-0.10 1.35 x 22.25(pack 0.32 dia. x 1.35)
(pack mass 11.5kg)
30
ManufacturingProcess::
Application Heat Flow In Heat Flow OutShed metal roof retrofit, fully sealed R-3.0 R-0.8Shed metal roof, with ceiling R-3.5 R-1.2Shed pitched metal roof 22°, ventilated R-2.5 R-1.1Shed metal clad wall, 100mm air gap R-1.1 R-1.2
Thermal Performance
R values shown are Total R values for the building element calculated by a chartered professional engineer and verified bya recognised laboratory. Total R values of the above systems for winter and summer conditions have been determined inaccordance with the requirements of AS/NZS4859.1:2002 Amdt 1 (2006), App K.
The contribution of this product total R-value depends on installation and environmental conditions. The R-value will bereduced in the event of the accumulation of dust on upward facing surfaces and in those cavities that are ventilated.
RHINO SHED
Product Description
Rhino Cell 310 Thermal Break is a 3 in 1 insulation, vapour barrier and radiant heat barrier for use in roof, wall and floor systems.
Rhino Shed is a 3 in 1 insulation, vapourbarrier and radiant heat barrier for use in shed walls and shed under-roof systems where antiglare is not requested.
The fibre-free, non-allergenic, formaldehyde free materials used in Rhino Shed provides a safe solution which is also easy to install.
Product Specification WIDTH: 1.350m LENGTH: 22.25m AREA: 30m2 THICKNESS: 4mm ± 1mm LAMINATE 1: Polyethylene weave
Al Foil BUBBLE COMPOSITION:
Polyethylene
LAMINATE 2: Polyethylene weave Al Foil
Proudly Manufactured by
Thor Building Products P/L
1300 880 828(07) 3219 6833
293 EARNSHAW ROADPO BOX 14
NORTHGATE QLD 4013
WWW.THORBUILDING.COM.AU
Manu fac tu red by
Finished Product Performance Compliance to AS 4859.1 &AS4200.1
TEST DESCRIPTION PARAMETER
ASTM E - 408 Emissivity reflective face = 0.03 ± 0.01 antiglare face = 0.05 ± 0.01
AS/NZS 4859.1 App – I Surface Corrosion Pass
AS/NZS 4859.1 App – H Corrosiveness Pass
ASTM 1530.2 Flammability Low (index ≤ 5)
ASTM 1530.3 Early Fire Hazard
Ignitability index - N/A Spread of Flame - ≤ 9
Heat Evolved Ind. - N/A Smoke developed Ind. - ≤ 5
AS/NZS 3837 Cone Calorimeter BCA Classification 1
AS 1301.448 Duty Rating, Tensile Strength EXTRA HEAVY
TAPPI T470 Duty Rating, Edge Tear Resistance EXTRA HEAVY
AS 2001.2.19 Bursting Strength Stated
AS 4201.1 Resistance to Dry Delamination Pass
AS 4201.2 Resistance to Wet Delamination Pass
AS 4201.3 Shrinkage ≤ 5%
AS 4201.4 Water Barrier Low
AS 4201.6 Absorbency Unclassified
ASTM E-96 Vapour Transmission Medium
Information Technology Solutions
WIDTH: 1.35m
LENGTH: 22.25m
AREA: 30m2
THICKNESS: 4mm ± 1mm
LAMINATE 1: Polyethylene weave Al Foil
BUBBLE COMPOSITION:
Polyethylene
LAMINATE 2: Polyethylene weave Al Foil
Product Code
Description Thickness
(mm)
R-Value (m2 K/W)
Dimensions (m)
m2 per pack
RC-CW AG
Rhino Cell Cavity Wall
4mm
R-0.10 1.35 x 22.25
(pack 0.32 dia. x 1.35) (pack mass 11.5kg)
30
Thor Building Products P/L
32 Lysaght Street
Acacia Ridge QLD 4110
PH 1300 880 828
www.thorbuilding.com.au
Cavity Wall
Product specification
Manufacturing Process:
Application Heat Flow In Heat Flow Out
Warehouse metal roof retrofit, fully sealed R-3.0 R-0.8
Floor, suspended timber enclosed sub floor R-3.1 R-1.6
Commercial office metal roof, with ceiling R-3.5 R-1.2
Residential Pitched Metal roof 22°, ventilated R-2.5 R-1.1
Brick veneer wall R-1.9 R-2.1
Thermal Performance
Product Description Rhino Cell Cavity Wall is a 3 in 1 insulation, vapour-permeable and radiant heat barrier for use in wall systems.
The fibre-free, non-allergenic, formaldehyde free materials used in Rhino Cell Cavity Wall provide a safe solution which is also easy to install.
Rhino Cell Cavity Wall is strong, durable, has low flammability index (≤5) and is both rodent and insect resistant.
Available in Blue Antiglare surface finish.
R values shown are Total R values for the building element calculated by a chartered professional engineer and verified by a recognised laboratory. Total R values of the above systems for winter and summer conditions have been determined in accordance with the requirements of AS/NZS4859.1:2002 Amdt 1 (2006), App K.
The contribution of this product total R-value depends on installation and environmental conditions. The R-value will be reduced in the event of the accumulation of dust on upward facing surfaces and in those cavities that are ventilated.
Finished Product PerformanceCompliance to AS 4859.1 &AS4200.1
TEST DESCRIPTION PARAMETERASTM E - 408 Emissivity reflective face = 0.03 ± 0.01
antiglare face = 0.05 ± 0.01AS/NZS 4859.1 App – I Surface Corrosion PassAS/NZS 4859.1 App – H Corrosiveness Pass
ASTM 1530.2 Flammability Low (index ≤ 5)
ASTM 1530.3 Early Fire Hazard
Ignitability index - N/ASpread of Flame - ≤ 9Heat Evolved Ind. - N/A
Smoke developed Ind. - ≤ 5AS/NZS 3837 Cone Calorimeter BCA Classification 1AS 1301.448 Duty Rating, Tensile Strength EXTRA HEAVYTAPPI T470 Duty Rating, Edge Tear Resistance EXTRA HEAVY
AS 2001.2.19 Bursting Strength StatedAS 4201.1 Resistance to Dry Delamination PassAS 4201.2 Resistance to Wet Delamination PassAS 4201.3 Shrinkage ≤ 5%AS 4201.4 Water Barrier LowAS 4201.6 Absorbency UnclassifiedASTM E-96 Vapour Transmission Medium
Information Technology Solutions
Product Code Description Thickness(mm)
R-Value(m2 K/W)
Dimensions (m) m2 per pack
RC-UF AG Rhino Underfloor 4mm R-0.10 0.50 x 30(pack 0.50 dia. x 1.50)
(pack mass 18.5g)
453 rolls per pack
ManufacturingProcess::
Application Heat Flow In Heat Flow OutWarehouse metal roof retrofit, fully sealed R-3.0 R-0.8Floor, suspended timber enclosed sub floor R-3.1 R-1.6Commercial office metal roof, with ceiling R-3.5 R-1.2Residential Pitched Metal roof 22°, ventilated R-2.5 R-1.1Brick veneer wall R-1.9 R-2.1
Thermal Performance
R values shown are Total R values for the building element calculated by a chartered professional engineer and verified bya recognised laboratory. Total R values of the above systems for winter and summer conditions have been determined inaccordance with the requirements of AS/NZS4859.1:2002 Amdt 1 (2006), App K.
The contribution of this product total R-value depends on installation and environmental conditions. The R-value will bereduced in the event of the accumulation of dust on upward facing surfaces and in those cavities that are ventilated.
Rhino Cell UNDERFLOOR
Product Description
Rhino Underfloor is a 3 in 1 insulation, vapour-permeable and radiant heat barrier for use in underfloor systems.
The fibre-free, non-allergenic, formaldehyde free materials used in Rhino Underfloor provide a safe solution which is also easy to install.
Rhino Underfloor is strong, durable, has low flammability index (≤5) and is both rodent and insect resistant.
Available in Blue Antiglare surface finish.
Product Specification WIDTH: 0.50m LENGTH: 30m AREA: 45m2 THICKNESS: 4mm ± 1mm LAMINATE 1: Polyethylene weave
Al Foil BUBBLE COMPOSITION:
Polyethylene
LAMINATE 2: Polyethylene weave Al Foil
Proudly Manufactured by
Thor Building Products P/L
1300 880 828(07) 3219 6833
293 EARNSHAW ROADPO BOX 14
NORTHGATE QLD 4013
WWW.THORBUILDING.COM.AU
Section 5RHINO FOAM INSULATION RANGE
• Rhino Foam 40
Fire retardant foam core laminated to two layers of high performance reflective woven aluminium foil
• Rhino Foam 75
Fire retardant foam core laminated to two layers of high performance reflective woven aluminium foil
• Rhino Insulsteel 65
Fire retardant foam core laminated to two layers of high performance reflective woven aluminium foil
by THOR BUILDING PRODUCTS
RHINOFOAM 40Thermal Break
Application Heat Flow In Heat Flow O
Pitched Metal Roof, flat ceiling (Fully-Sealed Airspace between Metal Roof & Oasis 7.0 Thermal Break) 2.8 1.3
Pitched Metal Roof (22° Warehouse) (Fully-Sealed Airspace between Metal Roof & Oasis 7.0 Thermal Break) 1.7 1
3.9 1.4Flat Metal Roof, suspended ceiling (Fully-Sealed Airspace between Metal Roof & Oasis 7.0 Thermal Break)
Flat Metal Roof (Warehouse) (Fully-Sealed Airspace between Metal Roof & Oasis 7.0 Thermal Break) 2.1 1
Metal Clad Wall 1.1 1.1
Metal Clad Wall & Plasterboard Lining 1.8 1.7Double Brick Wall 2.1 2.1Brick Veneer Wall 2 2
40Product DescriptionRhino Foam 40 AG Thermal Break combines an
inner layer of fire retardant foam core laminated to
two layers of high performance reflective woven
aluminium foil. This proudly Australian made
insulation features an anti-glare coating on one
side for safe, easy installation as well as advanced
thermal performance reflecting up to 97%
of radiant heat flow. Our Thermal break product
provides an energy efficient solution for roof and
wall applications in accordance with the BCA and
is proudly Australian made.
Unique: 1500mm flap eliminates need for overlap, saving up to 10%
Product specification
Finished Product PerformanceCompliance to AS 4859.1 &AS4200.1
Thermal PerformanceManufacturingProcess:
Thor Building Products P/L
293 Earnshaw Road
Northgate QLD 4013
PH 1300 880 828
www.thorbuilding.com.au
Application Heat Flow In Heat Flow Out
Pitched Metal Roof, flat ceiling (Fully-Sealed Airspace between Metal Roof & Oasis 7.0 Thermal Break) 2.8 1.3
Pitched Metal Roof (22° Warehouse) (Fully-Sealed Airspace between Metal Roof & Oasis 7.0 Thermal Break) 1.7 1
Flat Metal Roof, suspended ceiling (Fully-Sealed Airspace between Metal Roof & Oasis 7.0 Thermal Break 3.9 1.4
Flat Metal Roof (Warehouse) (Fully-Sealed Airspace between Metal Roof & Oasis 7.0 Thermal Break) 2.1 1
Metal Clad Wall 1.1 1.1
Metal Clad Wall & Plasterboard Lining 1.8 1.7
Doubel Brick Wall 2.1 2.1
Brick Veneer Wall 2 2
TEST DESCRIPTION PARAMETERASTM E - 408 Emissivity Silver 0.03 / Anti-Glare 0.05
AS/NZS 4859.1 App – I Surface Corrosion Pass
AS/NZS 4859.1 App – H Corrosiveness Pass
ASTM 1530.2 Flammability Low (index ≤ 5)
ASTM 1530.3 Early Fire Hazard0/0/0/1
AS/NZS 3837 Cone Calorimeter N/A
AS 1301.448 Duty Rating, Tensile Strength EXTRA HEAVY DUTY
TAPPI T470 Duty Rating, Edge Tear Resistance EXTRA HEAVY DUTY
AS 2001.2.19 Bursting Strength Stated
AS 4201.1 Resistance to Dry Delamination Pass
AS 4201.2 Resistance to Wet Delamination Pass
AS 4201.3 Shrinkage ≤ 5%
AS 4201.4 Water Barrier High
AS 4201.6 Absorbency High
ASTM E-96 Vapour Transmission Medium
SAFETY INSTRUCTIONSNo personal protective equipment is required,
however, it is recommended that UVprotective sunglasses be worn when installing
outside.This product is non-hazardous.
When installing ensure that all electricalcabling, fittings, and wiring are in a safe
condition and there is no potential for contactwith live wiring or down-lights. Ensure a
minimum 50mm clearance from light fittings(check for safe distance with lighting supplier)and ensure 50mm clearance around hot flues.
Plastic fixings should be used where anyelectrical componentry is in close vicinity of
the installation materials. Do not use anymetal fixings if working in close vicinity of
electrical wiring.
Product Code Description Thickness R-Value Dimensions (m) m2 per pack(m2K/W)
RF-40 AG Rhino Foam 40 AG 4.0mm R-0.10 1350mm x22.25m
(+0.15mFlap)
30
(mm)WIDTH: 1350mm (+0.15m Flap)
LENGTH: 22.25m
AREA: 30m
THICKNESS: 4.0 ± 1mm
ANTIGLARE REFLECTIVITY: 95%
SILVER REFLECTIVITY: 97%
RHINOFOAM 75Thermal Break
Application Heat Flow In Heat Flow O
Pitched Metal Roof, flat ceiling (Fully-Sealed Airspace between Metal Roof & Oasis 7.0 Thermal Break) 2.8 1.3
Pitched Metal Roof (22° Warehouse) (Fully-Sealed Airspace between Metal Roof & Oasis 7.0 Thermal Break) 1.7 1
3.9 1.4Flat Metal Roof, suspended ceiling (Fully-Sealed Airspace between Metal Roof & Oasis 7.0 Thermal Break)
Flat Metal Roof (Warehouse) (Fully-Sealed Airspace between Metal Roof & Oasis 7.0 Thermal Break) 2.1 1
Metal Clad Wall 1.1 1.1
Metal Clad Wall & Plasterboard Lining 1.8 1.7Double Brick Wall 2.1 2.1Brick Veneer Wall 2 2
75Product DescriptionRhino Foam 75 AG Thermal Break combines an
inner layer of fire retardant foam core laminated to
two layers of high performance reflective woven
aluminium foil. This proudly Australian made
insulation features an anti-glare coating on one
side for safe, easy installation as well as advanced
thermal performance reflecting up to 97%
of radiant heat flow. Our Thermal break product
provides an energy efficient solution for roof and
wall applications in accordance with the BCA and
is proudly Australian made.
Unique: 1500mm flap eliminates need for overlap, saving up to 10%
Product specification
WIDTH: 1350mm (+0.15m Flap)
LENGTH: 22.25m
AREA: 30m
THICKNESS: 7.5 ± 1mm
Finished Product PerformanceCompliance to AS 4859.1 &AS4200.1
Thermal PerformanceManufacturingProcess:
Thor Building Products P/L
293 Earnshaw Road
Northgate QLD 4013
PH 1300 880 828
www.thorbuilding.com.au
Application Heat Flow In Heat Flow Out
Pitched Metal Roof, flat ceiling (Fully-Sealed Airspace between Metal Roof & Oasis 7.0 Thermal Break) 2.8 1.3
Pitched Metal Roof (22° Warehouse) (Fully-Sealed Airspace between Metal Roof & Oasis 7.0 Thermal Break) 1.7 1
Flat Metal Roof, suspended ceiling (Fully-Sealed Airspace between Metal Roof & Oasis 7.0 Thermal Break 3.9 1.4
Flat Metal Roof (Warehouse) (Fully-Sealed Airspace between Metal Roof & Oasis 7.0 Thermal Break) 2.1 1
Metal Clad Wall 1.1 1.1
Metal Clad Wall & Plasterboard Lining 1.8 1.7
Doubel Brick Wall 2.1 2.1
Brick Veneer Wall 2 2
TEST DESCRIPTION PARAMETERASTM E - 408 Emissivity Silver 0.03 / Anti-Glare 0.05
AS/NZS 4859.1 App – I Surface Corrosion Pass
AS/NZS 4859.1 App – H Corrosiveness Pass
ASTM 1530.2 Flammability Low (index ≤ 5)
ASTM 1530.3 Early Fire Hazard0/0/0/1
AS/NZS 3837 Cone Calorimeter N/A
AS 1301.448 Duty Rating, Tensile Strength EXTRA HEAVY DUTY
TAPPI T470 Duty Rating, Edge Tear Resistance EXTRA HEAVY DUTY
AS 2001.2.19 Bursting Strength Stated
AS 4201.1 Resistance to Dry Delamination Pass
AS 4201.2 Resistance to Wet Delamination Pass
AS 4201.3 Shrinkage ≤ 5%
AS 4201.4 Water Barrier High
AS 4201.6 Absorbency Unclassified
ASTM E-96 Vapour Transmission Medium
SAFETY INSTRUCTIONSNo personal protective equipment is required,
however, it is recommended that UVprotective sunglasses be worn when installing
outside.This product is non-hazardous.
When installing ensure that all electricalcabling, fittings, and wiring are in a safe
condition and there is no potential for contactwith live wiring or down-lights. Ensure a
minimum 50mm clearance from light fittings(check for safe distance with lighting supplier)and ensure 50mm clearance around hot flues.
Plastic fixings should be used where anyelectrical componentry is in close vicinity of
the installation materials. Do not use anymetal fixings if working in close vicinity of
electrical wiring.
Product Code Description Thickness R-Value Dimensions (m) m2 per pack(mm) (m2K/W)
RF-75 AG Rhino Foam 75 AG 7.5mm R-0.20 1350mm x22.25m
(+0.15m Flap)
30
ANTIGLARE REFLECTIVITY: 95%
SILVER REFLECTIVITY: 97%
Information Technology Solutions
Rhino “Insulsteel 65.” “Insulsteel 65” has a thermal break to comply with the BCA standards* and the National Construction Code 2011, which requires an R0.20 thermal break for steel framed constructions to reduce thermal bridging and conductivity between the building products.
Rhino Insulsteel 65
A chemically cross-linked polyethylene foam structure, Insulsteel 65 is laminated on both sides, with highly reflective foil, with one side antiglare, making this product ideal as an Insulation as well as a Vapour Barrier and a Thermal Break.
*BCA Vol 1. Section J1.3(d) J1.5(b) (c) Vol 2.3.12.1.2(c) Roof 3.12.1.4 (b) Wall.
Rhino Insulsteel can also be used in other forms of construction such as tilt slab concrete walls, (with breather holes) brick veneer walls, and timber roofs. (Please consult our user and installation guide for further details).
Product Information Product Thickness
6.5mm (min)
Roll Size 22.25m x 1.350mm (30m2 )
Roll Weight 12kg
Roll Diameter 460mm
Reflectance Antiglare
92%
Reflective Side 97%
Max Span
Product Testing Test Test Standard Result
Corrosion Resistance AS/NZS 4859.1 Appen 1 Pass
Thermal Resistance AS/NZS 4859.1 ISO8302:1991 R0.216
Cone Calorimeter AS/NZS 3837 Group 1
Flammabilty AS 1530.2 Low Index <5
Ignitability Flame Spread Heat Release Smoke Release Emittance
AS 1530.3 0/0/0/1
ASTM-E408 Reflective E0.03 Anti-glare E0.08
Vapour Transmission ASTM E96-2005 Medium
Dry Delamination AS/NZS 4201.1-1994 Pass
Wet Delamination AS/NZS 4859.1-2002 App.1 Pass
Shrinkage AS/NZS 4201.3-1994 Complies – 0.3%
Duty AS 4200.1-1994 Table1. Complies
Extra Heavy Duty
Thermal Performance^ Construction Type Heat Flow In Heat Flow Out
Steel Stud Frames Wall Insulsteel 65
R1.68 R1.88
Brick Veneer Wall Insulsteel 65
R1.85 R2.11
Commercial Metal Roof Suspended Ceiling Insulsteel 65
Tilt Slab Concrete Office Wall Insulsteel 65
R1.9 R2.1
For other Thermal Performance figures please consult our Technical Data Sheet.
^ The R-Values shown were prepared and certified by James M. Fricker MIEAust. CPEng. Consultant engineer in insulation to the BCA, the NCC 2011, and the insulation industry. These values are based upon product in an in service condition, and are in accordance with AS/NZS 4859.1:2002.
Total R Values are based on product in-service conditions in accordance with AS/NZS 4859.1:2002/Amdt 1 (Dec 2006) including the alteration of insulation material R for temperature and derations of reflective foil emittances due to dust as noted. Where a cavity is sealed, it is assumed there is no dust and n=hence emittance is not derated.
ManufacturingProcess::
Rhino Insulsteel products carry a 10 year warranty on Commercial applications and a 15 year warranty on Domestic applications against Delamination and Oxidation.** subject to Thermacon Insulsteel Pty Ltd standard warranty guidelines (available upon request). **
Proudly Manufactured by
Thor Building Products P/L
1300 880 828(07) 3219 6833
293 EARNSHAW ROADPO BOX 14
NORTHGATE QLD 4013
WWW.THORBUILDING.COM.AU
Section 6RHINO WRAP REFLECTIVE FOIL RANGE
• Rhino Wrap (RP-51 & RP-51B)
Laminate of aluminium foil and polywoven fabric
• Rhino Foil (RF-51 & RF-51B)
Lighter wrap with improved bond strength
• Rhino Metal Roofing (RP-51MR)
Laminate of aluminium foil and polywoven fabric
• Rhino Roofing (RP-61)
Laminate of aluminium foil and polywoven fabric
• Rhino High Performance Roofing (RP-91 HP-15)
Extra heavy duty laminate of aluminium foil and polywoven fabric
• Rhino Multipurpose (RP-51WR)
Laminate of aluminium foil and polywoven fabric
• Rhino Tile & Metal Roofing (RP-51TM)
Laminate of aluminium foil and polywoven fabric
• Rhino Facing Foil
Rhino Blanket Facing reflective foil face faces down toward the air space under the roof and prevents airborne moisture from reaching the surface of the roof cladding, made with a high strength polywoven fabric facing which is applied to a glasswool blanket.
by THOR BUILDING PRODUCTS
Information Technology Solutions
PRODUCT INFORMATIONRhino Foil Products are speci�cally manufactured to the highest industry standards.WALL INSTALLATION: Up to R1.1 may be added to the wall system when Rhino Foil RF-51 & RF-51B is installed as wall cladding behind brick veneer/timber cladding. Our specialised manufacturing process bonds together Aluminium Foil to a high strength reinforcing Polymer Mesh using a �ame retardant adhesive. Our Reinforcing Polymer Mesh is purposely-treated blue in colour to reduce re�ective glare problems when Rhino Foil is installed.
RHINO FOIL RF-51 & RF-51B
Proudly Manufactured by
Thor Building Products P/L
1300 880 828(07) 3219 6833
293 EARNSHAW ROADPO BOX 14
NORTHGATE QLD 4013
WWW.THORBUILDING.COM.AU
THE ULTIMATE PROTECTION
Satisfy BCA speci�cations and requirements for Re�ective Foil Laminates. Complies with the speci�cations and requirements of AS/NZS 4200.1 for "Pliable Building
Membranes" which is a manual recognised by the BCA Part 3.5 Roof and Cladding. Low Flammability Index in accordance with AS 1530.2 <5 Satisfy BCA Part 3.7.1 Fire Hazard Properties. Satisfy Health & Safety Regulations.
DutyCommercial Wall InsulationResidential Wall Insulation
Medium
Vapour barrier High
EmittanceWater barrier High
Reflective Reflective
Flammability Index < 5 < 5
Tensile Strength Machine Direction (kN/M) min 9.5
Tensile Strength Lateral Direction (kN/M) min 6.0
Edge Tear Resistance Machine Direction (N) min 65
Edge Tear Resistance Lateral Direction (N) min 65
Water Vapour Transmission Rate (Ng/Ns)Emmittance of Reflective Face
max 2
max 0.05
Medium
RF-51 RF-51B
Low
Unclassified
< 5
min 9.5
min 6.0
min 65
min 65
min 140
max 0.05
Width 1350MM Length 30M Area 40.5M 2
Width 1350MM Length 60M Area 81M 2
Availability
Recommended Applications and Properties
LIGHT WEIGHTSUPER STRENGTHHOUSE WRAPRF-51RF-51B
RHINO FOIL USAGEIn all applications:• External cladding should be installed A.S.A.P• No contact is to be made with wet concrete or mortar• Store in dry area, weather proofed only after installation• Shrinkage of up to 2% can be expected
In re�ective foil laminate applications:• Use only in accordance with AS/NZS 4200.2 for the
"Installation Requirements for Pliable Building Membranes"• Minimum of 20mm air space is recommended adjacent to
re�ective foil face to achieve Maximum insulation values
... theultimateprotection!
WALLWRAPRP-51
RP-51B
RHINO WRAP RP-51 & RP-51B
Product Information Rhino Wrap Products are specifically manufactured to the highest industry standards.
WALL INSTALLATION: Up to R1.1 may be added to the wallsystem when Rhino Wall Wrap is installed as wall
cladding behind brick veneer/timber cladding. Ourspecialised manufacturing process bonds togetherAluminium Foil to a high strength reinforcing PolymerMesh using a flame retardant adhesive. OurReinforcing Polymer Mesh is purposely-treated blue incolour to reduce reflective glare problems
when Rhino Wrap is installed.
Rhino Wrap UsageIn all applications:
• External cladding should be installed A.S.A.P
• No contact is to be made withwet concrete or mortar
• Store in dry area, weather proofed only afterinstallation
• Shrinkage of up to 2% can be expected
In reflective foil laminate applications:
• Use only in accordance with AS/NZS 4200.2 forthe "Installation Requirements for PliableBuilding Membranes"
• Minimum of 20mm air space is recommendedadjacent to reflective foil face to achieveMaximum insulation values
Aluminium foil
poooymmmerr mmeesshh
RReeinnforcc nngg
Footing
Flooring
Floor JointBearerBottom
PlateTi
mbe
r Stu
ds
Ceiling Joint
Insulation
Rafter
Anti-PondingBoard
RafterRoof Batten
Roof Tiles
Under Battens(where required)
• RP-51 Wall Wrap • RP-51B Breather
• RP-61 (HD)• RP-81 (EHD)
Applications
... theultimateprotection!
Phone: 1300 880 828
By: THOR Building Products
•Width 1500mm ........Length 60 metres............Area 90m2
Recommended Applications
PRODUCT DATA SHEET
RHINO ROOFING
Satisfy BCA specifications and requirements for Reflective Foil LaminatesComplies with the specifications and requirements of AS/NZS 4200.1 for"Pliable Building Membranes" which is a manual recognised by theBCA Part 3.5 Roof and CladdingLow Flammability Index in accordance with AS 1530.2 <5Satisfy BCA Part 3.7.1 Fire Hazard PropertiesSatisfy Health & Safety Regulations
Totally Australian OwnedManufactured in Australia from
Local and Imported Components
32 Lysaght Street, Acacia Ridge, QLD 4110PO Box 1140, Archerfield BC, QLD 4108
Fax: (07) 3219 6833Email: [email protected]
Residential Wall Insulation
hgiHreirrab ruopaV
hgiHreirrab retaW
5<5< xednI ytilibammalF
Availability
Recommended Applicationsand Properties
Tensile Strength Machine Direction (kN/m) min 12.5
Tensile Strength Lateral Direction (kN/m) min 7.5
Edge Tear Resistance Machine Direction (N) min 80
Edge Tear Resistance Lateral Direction (N) min 80
•Width 1350mm...Length 30 metres...Area 40.5m2
Water vapour Transmission Rate (Ng/Ns) max 2
Duty Heavy
•Width 1350mm...Length 60 metres...Area 81m2
Emittance Reflective
Emittance of Reflective Face max 0.05
Low
Unclassified
<5
min 12.5
min 7.5
min 80
min 80
min 140
Heavy
Commercial Wall Insulation
Reflective
max 0.05
RP-51 RP-51B
RP-51 WALL WRAPRP-51B Breather
PRODUCT DATA SHEET RHINO WRAP RP-51 & RP-51B
HEAVY DUTYWALL WRAPRP-51RP-51B
the ultimate p r o t e c t i o n
PRODUCT INFORMATION
Rhino WRAP USAGE
Satisfy BCA speci�cations and requirements for Re�ective Foil Laminates Complies with the speci�cations and requirements of AS/NZS 4200.1 for "Pliable Building
Membranes" which is a manual recognised by the BCA Part 3.5 Roof and Cladding Low Flammability Index in accordance with AS 1530.2 <5 Satisfy BCA Part 3.7.1 Fire Hazard Properties Satisfy Health & Safety Regulations
Rhino Wrap Products are speci�cally manufactured to the highest industry standards.
WALL INSTALLATION: Up to R1.1 may be added to the wall system when Rhino Wrap RP-51 & RP-51B is installed as wall cladding behind brick veneer/timber cladding. Our specialised manufacturing process bonds together Aluminium Foil to a high strength reinforcing Polymer Mesh using a �ame retardant adhesive. Our Reinforcing Polymer Mesh is purposely-treated blue in colour to reduce re�ective glare problems when Rhino Wrap is installed.
In all applications:• External cladding should be installed A.S.A.P• No contact is to be made with wet concrete or mortar• Store in dry area, weather proofed only after installation• Shrinkage of up to 2% can be expected
In re�ective foil laminate applications:• Use only in accordance with AS/NZS 4200.2 for the
"Installation Requirements for Pliable Building Membranes"• Minimum of 20mm air space is recommended adjacent to
re�ective foil face to achieve Maximum insulation values
Totally Australian owned manufactured in Australia from local & imported components
by THOR BUILDING PRODUCTS
RP-91-HP (EHD)
Width 1500MM Length 30M Area 45M 2
Width 1500MM Length 60M Area 90M 2
DutyCommercial Wall InsulationResidential Wall Insulation
Heavy
Vapour barrier High
EmittanceWater barrier High
Reflective Reflective
Flammability Index < 5 < 5
Tensile Strength Machine Direction (kN/M) min 12.5
Tensile Strength Lateral Direction (kN/M) min 7.5
Edge Tear Resistance Machine Direction (N) min 80
Edge Tear Resistance Lateral Direction (N) min 80
Water Vapour Transmission Rate (Ng/Ns)Emmittance of Reflective Face
max 2
max 0.05
Heavy
RP-51 RP-51B
Low
Unclassified
< 5
min 12.5
min 7.5
min 80
min 80
min 140
max 0.05
Width 1350MM Length 30M Area 40.5M 2
Width 1350MM Length 60M Area 81M 2
Availability
Recommended Applications and Properties
PO BOX 14 NORTHGATE QLD 4013
1300 880 828 ( 07) 3246 [email protected] EARNSHAW ROAD
www.thorbuilding.com.au
Information Technology Solutions
PRODUCT INFORMATION
Rhino Roofing Products are specifically manufactured to the highest industry standards.
ROOF INSTALLATION - Up to R1.3 may be added to insulation system when Rhino RP-51MR is installed. Our specialised manufacturing process bonds together Aluminium Foil to a high strength reinforcing Polymer Mesh using a flame retardant adhesive. Our Reinforcing Polymer Mesh is purposely treated blue in colour to reduce reflective glare problems when installing Roofing Products.
RP-51MR Metal Roofing
Membranes" which is a manual recognised by the BCA Part 3.5 Roof and Cladding Low Flammability Index in accordance with AS 1530.2 < 5 Satisfy BCA Part 3.7.1 Fire Hazard Properties Satisfy Health and Safety Regulations
• RP-51 Wall Wrap• RP-51B Breather
• RP- 51MR Metal Roo�ng
RHINO METAL ROOFING USAGEIn all applications:• External cladding should be installed A.S.A.P • No contact is to be made with wet concrete or mortar• Store in dry area, weather proofed only after installation• Shrinkage of up to 2% can be expected
• Use only in accordance with AS/NZS 4200. 2 for the "Installation Requirements for Pliable Building Membranes"
• Minimum of 20MM air space is recommended adjacent to
• 40MM sag between trusses is recommended when using Rhino RP-51MR
• For use in enclosed structuresNOTE: Use in cold temperature climates (daytime < 5°C) requires roof to be well ventilated and moist air from within the dwelling to be exhausted out into the atmosphere.
Duty
Recommended Applications and PropertiesResidential & Commercial Roof Insulation
HeavyVapour barrier HighEmittanceWater barrier HighFlammability Index < 5 < 5Tensile Strength Machine Direction (kN/M) min 12.5Tensile Strength Lateral Direction (kN/M) min 7.5Edge Tear Resistance Machine Direction (N) min 80Edge Tear Resistance Lateral Direction (N) min 80Water Vapour Transmission Rate (Ng/Ns) max 2
max 0.05AvailabilityWidth 1350MM Length 30M Area 40.5M 2
Width 1350MM Length 60M Area 81M 2
Proudly Manufactured by
Thor Building Products P/L
1300 880 828(07) 3219 6833
293 EARNSHAW ROADPO BOX 14
NORTHGATE QLD 4013
WWW.THORBUILDING.COM.AU
R H I N OM E T A LROOFINGRP-51MR
THE ULTIMATE PROTECTION
Information Technology Solutions
PRODUCT INFORMATION
Rhino Roofing Products are specifically manufactured to thehighest industry standards.
RHINO ROOFING RP-61
Proudly Manufactured by
Thor Building Products P/L
1300 880 828(07) 3219 6833
293 EARNSHAW ROADPO BOX 14
NORTHGATE QLD 4013
WWW.THORBUILDING.COM.AU
THE ULTIMATE PROTECTION
R H I N OROOFINGR P - 6 1
Satisfy BC tions and requirements for R tive Foil Laminates C tions and requirements of AS/NZS 4200.1 for
Low Flammability Index in accordance with AS 1530.2 < 5 Satisfy BCA Part 3.7.1 Fire Hazard Properties Satisfy Health and Safety Regulations Complies with AS/NZS 4040.4 Impact Resistance (Sandbag Test)
"Pliable Building Membranes" which is a manual recognised by the BCA Part 3.5 Roof and Cladding
ENERGY EFFICIENCY - Rhino R -61 pro ective reductions in greenhouse gas emissions when used in an insulation agent in buildings. Preferred seasonal gains in required temperatures are assured.
LIGHT REFLECTIVITY - Gains of up to 40% can be obtained by using Rhino R -61 as an exposed internal roof lining.
ting loads are also evident. Conforms to AS/NZS 4859.1-2002.
PROTECTIVE ROOF/VAPOUR BARRIER - Added protection against stormwater, condensation and wind is
ver ective vapour barrier when sealed with recommended tapes.
added to the insulation System R-Value when Rhino Roofing RP61 is installed adjacent to an airspace in tiled roof structures.
ROOF INSULATION - Up to R1.0 (downward heat flow) may be
Aluminium Foil and high density Kraft Paper that is then laminated with a high strength Our Reinforcing Polymer Mesh is purposely-treated blue in colour to reduce r tive glare problems when Rhino R . To achieve and ensure maximum protection is attained, Flame Retardant Adhesive is applied during ocess of
reinforcing Polymer Mesh.
Our specialist manufacturing process bonds together
manufacture in all Rhino Roofing Products.
achieved in roof structures when applied under roof tiles. Rhino R -61 can also be a
In all applications:• External cladding should be
installed A.S.A.P • No contact is to be made with
wet concrete or mortar• Store in dry area, weather
proofed only after installation• Shrinkage of up to 2% can be
expected
In r tive foil laminate applications:• Use only in accordance with
AS/NZS 4200. 2 for the "Installation Requirements for Pliable Building Membranes"
• Minimum of 20MM air space is recommended adjacent to r tive foil face to achieve Maximum insulation values
• 40MM sag between trusses is recommended when using Rhino R -61
• For use in enclosed structures
Recommended Applications and Properties
Residential &Commercial Roof Insulation Flame Retardant - Cladding Duty HeavyVapour Barrier HighEmittance ReflectiveWater Barrier HighFlammability Index < 5 < 5Tensile Strength Machine Direction (kN/M) min 12.5Tensile Strength Lateral Direction (kN/M) min 7.5Edge Tear Resistance Machine Direction (N) min 80Edge Tear Resistance Lateral Direction (N) min 80Water Vapour Transmission Rate (Ng/Ns) max 2Emittance of Reflective Face max 0.05Availability
Width 1500MM Length 30M Area 45M 2
HighTensile strength - CladdingDurability - Cladding HighImpact Resistant - Cladding High
RHINO ROOFING RP-61 USAGE
PRODUCT INFORMATION
Information Technology Solutions
PRODUCT INFORMATION
Rhino Roofing Products are specifically manufactured to thehighest industry standards.
HIGH PERFORMANCE RP-91-HP-15
Proudly Manufactured by
Thor Building Products P/L
1300 880 828(07) 3219 6833
293 EARNSHAW ROADPO BOX 14
NORTHGATE QLD 4013
WWW.THORBUILDING.COM.AU
THE ULTIMATE PROTECTION
R H I N OROOFINGR P - 9 1H I G HPERFORMANCE
"Pliable Building Membranes" which is a manual recognised by the BCA Part 3.5 Roof and Cladding Low Flammability Index in accordance with AS 1530.2 < 5 Satisfy BCA Part 3.7.1 Fire Hazard Properties Satisfy Health and Safety Regulations Complies with AS/NZS 4040.4 Impact Resistance (Sandbag Test)
PRODUCT INFORMATIONROOF INSULATION - Up to R1.0 (tiled) & R1.3 (Metal) may be
is installed within an airspace in roof structures. Our specialised manufacturing process laminates Aluminium Foil with a high strength reinforcing Polymer Mesh.
ENERGY EFFICIENCY -
used as an insulation agent in buildings.
LIGHT REFLECTIVITY - Gains of up to 40% can be obtained
to AS/NZS 4859.1-2002.
PROTECTIVE ROOF/VAPOUR BARRIER - Added protection against stormwater, condensation and wind is achieved in roof structures when applied under roof tiles or metal roofs.
barrier when sealed with recommended tapes.
In all applications:• External cladding should be
installed A.S.A.P • No contact is to be made with wet
concrete or mortar• Store in dry area, weather proofed
only after installation• Shrinkage of up to 2% can be
expected
applications:• Use only in accordance with
AS/NZS 4200. 2 for the "Installation Requirements for Pliable Building Membranes"
• Minimum of 20MM air space is recommended adjacent to
Maximum insulation values• 40MM sag between trusses is
recommended when using Rhino
• For use in enclosed structures
NOTE: Use in cold temperature climates (daytime < 5°C) requires roof to be well ventilated and moist air from within the dwelling to be exhausted out into the atmosphere.
Recommended Applications and PropertiesTensile strength - Cladding HighDurability - Cladding HighImpact Resistant - Cladding HighResidential &Commercial Roof Insulation High Wind Load Protection Acoustic Performance Agent Flame Retardant - Cladding Duty Extra HeavyVapour Barrier HighEmittance ReflectiveWater Barrier HighFlammability Index < 5 < 5Tensile Strength Machine Direction (kN/M) min 13.0Tensile Strength Lateral Direction (kN/M) min 10.5Edge Tear Resistance Machine Direction (N) min 90Edge Tear Resistance Lateral Direction (N) min 90Water Vapour Transmission Rate (Ng/Ns) max 2Emittance of Reflective Face max 0.05Availability
Width 1500MM Length 30M Area 45M 2
RHINO ROOFING (EHD) USAGE
Information Technology Solutions
PRODUCT INFORMATIONRhino Wrap Products are specifically manufactured to the highest industry standards.
WALL INSTALLATION - Up to R1.1 may be added to the wall system when Rhino Multi Purpose Wrap is installed as wall cladding behind brick veneer/timber cladding.
ROOF INSTALLATION - Up to R1.3 may be added to insulation system when Rhino Multi Purpose Wrap is installed.
Our specialised manufacturing process bonds together Aluminium Foil to a high strength reinforcing Polymer Mesh using a flame retardant adhesive. Our Reinforcing Polymer Mesh is purposely treated blue in colour to reduce reflective glare problems when Rhino Multi Purpose wrap is installed.
RP-51-WR MULTI PURPOSE
Proudly Manufactured by
Thor Building Products P/L
1300 880 828(07) 3219 6833
293 EARNSHAW ROADPO BOX 14
NORTHGATE QLD 4013
WWW.THORBUILDING.COM.AU
THE ULTIMATE PROTECTION
RHINO MULTI PURPOSE WRAP USAGE
R H I N O M U L T IP U R P O S EWALL & METAL ROOF
Information Technology Solutions
PRODUCT INFORMATION
Rhino Roofing Products are specifically manufactured to thehighest industry standards.
RP-51TM TILE & METAL ROOFING
Proudly Manufactured by
Thor Building Products P/L
1300 880 828(07) 3219 6833
293 EARNSHAW ROADPO BOX 14
NORTHGATE QLD 4013
WWW.THORBUILDING.COM.AU
THE ULTIMATE PROTECTION
R H I N OTILE & METAL
ROOFINGRP-51TM
Membranes" which is a manual recognised by the BCA Part 3.5 Roof and Cladding Low Flammability Index in accordance with AS 1530.2 < 5 Satisfy BCA Part 3.7.1 Fire Hazard Properties Satisfy Health and Safety Regulations
Duty
Recommended Applications and PropertiesResidential & Commercial Roof Insulation
HeavyVapour barrier HighEmittanceWater barrier HighFlammability Index < 5 < 5Tensile Strength Machine Direction (kN/M) min 12.5Tensile Strength Lateral Direction (kN/M) min 7.5Edge Tear Resistance Machine Direction (N) min 80Edge Tear Resistance Lateral Direction (N) min 80Water Vapour Transmission Rate (Ng/Ns) max 2
max 0.05AvailabilityWidth 1500MM Length 30M Area 45M 2
Width 1500MM Length 20M Area 30M 2
In all applications:• External cladding should be installed A.S.A.P • No contact is to be made with wet concrete or mortar• Store in dry area, weather proofed only after installation• Shrinkage of up to 2% can be expected
• Use only in accordance with AS/NZS 4200. 2 for the "Installation Requirements for Pliable Building Membranes"
• Minimum of 20MM air space is recommended adjacent to
• 40MM sag between trusses is recommended when using Rhino RP-51TM
• For use in enclosed structuresNOTE: Use in cold temperature climates (daytime < 5°C) requires roof to be well ventilated and moist air from within the dwelling to be exhausted out into the atmosphere.
RHINO TILE & METAL ROOFING USAGE
ROOF INSTALLATION - Up to R1.3 may be added to insulation system when Rhino RP-51TM is installed. Our specialised manufacturing process bonds together Aluminium Foil to a high strength reinforcing Polymer Mesh using a flame retardant adhesive. Our Reinforcing Polymer Mesh is purposely treated blue in colour to reduce reflective glare problems when installing Roofing Products.
RHINO BLANKET FACING(HEAVY & EXTRA HEAVY DUTY)
PRODUCT INFORMATION
Thor’s Blanket Facing is made with a high strength polywoven fabric facing which is applied to a glasswool blanket whilst other products commonly use a double sided foil with fibre mesh for the facing.
The polywoven fabric provides the additional benefits of:
outstanding tensile and tear strength
unrolls more easily right the way to the end of the roll
an excellent visible surface finish
APPLICATIONDesigned for application under metal, fibre cement, and concrete roof cladding Thor’s Blanket Facing eliminates the problems associated with condensation build up on the underside of the roof cladding. The reflective foil face faces down toward the air space under the roof and prevents airborne moisture from reaching the surface of the roof cladding.
NOTE: Use in cold temperature climates (daytime <5oC) requires roof to be well ventilated and moist air from within the dwelling to be exhausted out into the atmosphere.
FACING OPTIONS
The Duty Rating, Colour and Material Finish of the blanket facing can be varied to suit your application.
Colour Gloss White
Gloss Silver-Grey
Matt Dark Blue
Duty Extra Heavy Heavy Heavy
Width 1350 1350 1350
Residential & Commercial Insulation
Vapour barrier High High High
Emittance Reflective Reflective Reflective
Water barrier High High High
Flammability Index Low (≤5) Low (≤5) Low (≤5)
UV treated non reflective face (not direct sunlight)
Tensile Strength Machine Direction (kN/m) min 13.0 min 12.5 min 12.5
Tensile Strength Lateral Direction (kN/m) min 10.5 min 7.5 min 7.5
Edge Tear Resistance Machine Direction (N) min 90 min 80 min 80
Edge Tear Resistance Lateral Directions (N) min 90 min 80 min 80
Water Vapour Transmission Rate (Ng/Ns) max 2 max 2 max 2
Emittance of Reflective Face max 0.05 max 0.05 max 0.05
Proudly Manufactured by
Thor Building Products P/L
1300 880 828(07) 3219 6833
293 EARNSHAW ROADPO BOX 14
NORTHGATE QLD 4013
WWW.THORBUILDING.COM.AU
Satisfy BCA specifications and requirements for Reflective Foil Laminates
Complies with the specifications and requirements of AS/NZS 4200.1 for "Pliable Building Membranes" which is a manual recognised by the BCA Part 3.5 Roof and Cladding
Low Flammability Index in accordance with AS 1530.2 ≤ 5
Satisfy BCA Part 3.7.1 Fire Hazard Properties
Satisfy Health and Safety Regulations
Section 7RHINO PIR BOARD RANGE
• Rhino PIR Board
High performance, zero – ozone depleting insulation solution
by THOR BUILDING PRODUCTS
Rhino PIR Board
Applications include:Soffit Board
Cavity Wall BoardAll Purpose (AP) Framing Board
Rhino PIR Board
Product Thickness mm 25, 27, 31, 42, 55, 66, 77, 88, 99
Board Size – Length mm 2286
Board Size – Width mm 1219
Reflectance (Foil Side) 96%
25mm27mm
31mm42mm55mm
66mm
77mm88mm
99mm
R1.14R1.2
R1.4R1.9R2.5
R3.0
R3.5R4.0
R4.5
‘R’ Value
Product Testing
Test Test Standard Result
Compressive Strength ASTM C1289-12 >110 Pass
Thermal Conductivity ASTM C518-10 0.022
Cone Calorimeter AS/NZS 3837 Group 1
Ignitability FlameSpread
Heat ReleaseAS/NZS 1530.3 0/0/0/1
Smoke Release
Emmittence ASTM C1371 Reflective E0.04 “The Soffit Insulation shall be Thermacon CI MaxPolyisocyanurate (PIR) Foam Soffit Board mm
Water Absorbtion ASTM C1289-12 0.1 Pass
Water VapourPermeance 25mm
ASTM C1289-12 3 Pass Thick comprising of a CFC/HCFC free ridged uniformclosed cell PIR Foam core, bonded on each side to a foil and glass mat facer, manufactured by Johns Manville in the USA. This board is to be installed in accordance with the instructions issued by Thermacon Insulation Pty Ltd.”
Corner Burn Test NFPA 286 Pass
Service Temperature -73°C to122°C
Above Test
Rhino PIR Board is an Australian made and tested prefabricated
heat insulating elements for a variety of applications in the
building and domestic industry, which consists of flexible cover
sheets connected with a high bond to a cored polyisocyanurate foam.
The cover sheets can be made of different materials, such as
aluminium foil, mineral and glass fleeces and paper. The boards
are available in thicknesses between 25 to 150 mm and lengths up to 10 meters.
The polyisocyanurate foam, a three-dimensionally networked thermo set, is made from synthetic
polymers, which are combined with a CFC- and HCFC free blowing agent (zero CCP) in an expansion
process to form microscopic cells throughout the material. Our laminates offer a combination of
structural properties and capacities of cost-effective system building and energy conservation at minimal
weight along with low water absorption, thermal and acoustic insulation and good chemical resistance at
good aging stability.
Rhino PIR Board sets a new standard in PIR insulation system as it offers a more cost effective,
high performance, zero - ozone depleting PIR insulated solution. Rhino PIR Board is available with
facings of, bright silver foil, craft paper and white fibreglass finish.
Rhino PIR Board has great thermal properties which will save energy for heating, cooling and lighting.
Its acoustic properties will also help in reducing noise.
Rhino PIR Board is available in thicknesses of 25mm through to 100mm in 5mm increments.
Core PIR (Fire-retardant Polyisocyanurate)
Width (mm) 1200
Thickness (mm) 25 through to 100 in 5mm increments
Length (mm) 2400
Interior Facing Skin Silver Foil, Craft Paper, White Fibreglass
Exterior Facing Skin Silver Foil, Craft Paper, White Fibreglass
Installation of Rhino PIR Board as a concrete soffit:
Where Rhino PIR Board is exposed to external wind loads ensure
fasteners chosen for the install are in conjunction with AS/NZS 1170.2 -
Wind load standards.
1. Place Rhino PIR Board against the underside of the concrete slab.
2. Use fasteners that incorporate washers with a head diameter of not less than 35mm diameter
(for example: using Hilti X-IE6 Insulation fasteners) boards can either be in a square or staggered
pattern. Begin to affix the boards to the underside of the concrete in accordance with manufacturer's
guidelines.
3. Continue fixing each board following the below minimum fixing layout, each board that is
2400mm x 1200mm must be fixed with no less than 8 fasteners. For the fasteners around the
perimeter of the board must be between 50mm and 150mm from the edge of the board.
Fastener configuration, B per 2400mm x 1200mm board - 2.78 fixings Im‘.
4. Repeat the above steps to install the Rhino PIR Board in a continuous layer on the underside of
the concrete slab.
5. Tape all joins with a minimum 96mm wide Insulation tape. Following the manufacturer's
installation guidelines. Ensure to seal around the perimeter and joins, this will prevent air flow
between any air cavities formed below or above the boards.
Panel Properties
Panel Thickness (mm) 25 40 50 60 65
Mass (kg/m3)** 1.3 1.9 2.2 2.8 3
Thermal Performance
(based on NATA endorsed k = 0.020355 W/mK at 23 C)
Initial 'U' Value (W/m2K) 0.81 0.51 0.41 0.34 0.31
Initial 'R' Value (m2K/W) 1.23 1.97 2.46 2.95 3.19
Panel Properties
Panel Thickness (mm) 70 75 80 90 100
Mass (kg/m3)** 3.2 3.3 3.6 3.7 3.8
Thermal Performance
(based on NATA endorsed k = 0.020355 W/mK at 23 C)
Initial 'U' Value (W/m2K) 0.29 0.27 0.25 0.23 0.2
Initial 'R' Value (m2K/W) 3.44 3.68 3.93 4.42 4.91
NOTES:
• Taken from NATA endorsed test report and using ISO 10456, table A.4 for the
calculation of k-values at 23 deg C
••May vary depending on facing materials used. Typical value based on boards
being
manufactured with Aluminium Foil external facing. Craft Paper on Internal facing.
Please find the Installation Guide for:Soffit Board - Cavity Wall Board - All Purpose (AP) Framing Board on our website: www.thorbuilding.com.au
Rhino PIR Board – Use in Concrete Wall System:
System calculation assumes incorporation of 100mm concrete, 70mm thick RHINO PIR Board insulation
(reflective surface facing into the airspace below).
Concrete wall – Rhino PIR Boardinsulation directly fixed to concrete
Wall (no internal lining) RT 2.9
System calculation assumesincorporation of 150mm concrete,
55mm thick Rhino PIR Boardinsulation (reflective surface
facing internally).
Concrete wall – Rhino PIR Boardinsulation directly fixed to concrete
Wall (with internal lining) RT 2.8
System calculation assumes incorporation of 150mm concrete,
40mm thick Rhino PIR Board insulation, 24mm reflective airspace (created using steel
batten), 10mm plasterboard lining.
Rhino PIR Board – Use in Brick Veneer Wall System:
System calculation assumes incorporation of 110mm clay brick,45mm airspace, 35mm thick RHINO PIR Board insulation,
55mm reflective air space, 10mm plasterboard lining. .
Brick Veneer Wall – Rhino PIR Boardinsulation positioned within
wall frame RT 2.8
System calculation assumes incorporation of 110mm clay
brick, 20mm reflective airspace, 25mm thick Rhino PIR insulation, 90mm reflective airspace, 10mm
plasterboard lining.
System calculation assumes incorporation of 110mm clay
brick, 45mm airspace, 35mm thick Rhino PIR insulation, 55mm reflective air space, 10mm
plasterboard lining.
Brick Veneer Wall – Rhino PIR Boardinsulation positioned towards external
side of wall frame RT 2.9
Rhino PIR Board – Use in Brick Veneer Wall System:
Brick Veneer Wall – Rhino PIR Boardinsulation positioned towards internal side
of wall frame RT 2.9
System calculation assumes incorporation of 110mm clay brick, 45mm airspace, 90mm
reflective airspace, 35mm Rhino PIR Board insulation, 10mm
plasterboard lining.
Cavity brick wall – Rhino PIR Boardinsulation positioned adjacent
to the inner leaf RT 2.8
System calculation assumes incorporation of 110mm clay
brick, 20mm reflective airspace, 35mm thick Rhino PIR Board insulation, 110mm clay brick.
Section 8ROCKWOOL
• Rhino Rockwool Fire Seal Batts
provide up to 4 hours fire resistance at the junctions between the top of party walls and roof structures, and to the diverse junctions of com-partment walls and floors. A highly robust mineral wool that remains stable at high temperatures.
by THOR BUILDING PRODUCTS
Product: Roxul ® Stonewool P.D.S
Type: FIRE PROTECTION 39
Name: Page 1 of 4
REVISION: 2
DATE OF ISSUE: April ‘04
PRODUCT DATA SHEET CHKD: BH APPV: IRS
.
Thickness (mm)
Dimension (mm)
Pieces per Pack
Pack Contents (m2)
100 1200 x 168 10 2.016
Fusion Temperature: > 1120°C - Melting point to flow of Roxul® Stonewool fibre.
Thermal Conductivity (typical data): Tested in accordance with DIN 52612
Mean Temp 0C
50 100 150 200 250 300
K value W/m. K
0.038 0.044 0.052 0.062 0.074 0.088
Note: The above are declared thermal conductivity performances and are based
on the mean value of many Roxul laboratory and independent testing authority test results.
Fire Resistance: Fire resistance performance was tested by CSIRO in
INTEGRITY 4 HOURS INSULATION 4 HOURS
Product Performance and Properties
Description
RHINO ROCKWOOL FIRE SEAL BATTS
Rhino Rockwool Fire Seal Batts have been developed to provide up to 4 hours fire-resistance at the junctions between the top of party walls and roof structures, and to the diverse junctions of compartment walls and floors. It is a highly robust mineral wool that remains dimensionally stable at extremely high temperatures.
AUSTRALASIAN INSULATION SUPPLIES
accordance with A.S. 1530 Part 4 (Fire resistance tests of elements of building construction), and A.S. 4072-1992 (Components for the protection of openings in fire separating elements – Service penetrations and control joints. As a result of this testing a 200mm thick specimen of Roxul Party Wall Fire Stop achieved:
Product: Roxul ® Stonewool P.D.S
Type: FIRE PROTECTION 39
Name: Page 2 of 4
REVISION: 2
DATE OF ISSUE: April ‘04
PRODUCT DATA SHEET CHKD: BH APPV: IRS
Fire: Roxul® Stonewool Party Wall Fire Stop is non- combustible when tested according to international standards e.g. ASTM E-136-82, DIN 4102, BS476 Pt4-1970, ISO 1182 and IMO A 799 (19).
Corrosion Resistance: Roxul® Stonewool base mineral wool is chemically Chemical Neutrality: neutral and will neither cause nor promote corrosion.
Corrosion Resistance: Roxul® Stonewool base mineral wool has a very Water Leachable Chlorides: low content of water leachable chloride, approximately 6
ppm, so it can be safely used on austenitic stainless steel. Meets the requirements for use over stainless steel in accordance with ASTM C795 and of “AS-Quality” of AGI Q135.
Moisture Resistance Vapour Diffusion: Water vapour diffusion resistance factor of µ = 1.3. This low value means that water can pass through and cool without condensing.
Moisture Resistance: Roxul® Stonewool absorbs very little water from the air. Absorption from the air: Tests show at relative humidity of 90% for 30 days the
hygroscopic water content is around .004 volume per cent. The water vapour absorption (vapor sorption) in accordance with ASTM C110 4/C 110 M is + 0.02% (vol).
Specific Heat: Roxul® Stonewool specific heat factor is 0.84 kJ/kg per degree centigrade.
Calorific Value: Roxul® Stonewool has a low organic matter content giving a low caloric value of around 600 kJ/kg.
RHINO ROCKWOOL FIRE SEAL BATTS
AUSTRALASIAN INSULATION SUPPLIES
Product: Roxul ® Stonewool P.D.S
Type: FIRE PROTECTION 39
Name: Page 3 of 4
REVISION: 2
DATE OF ISSUE: April ‘04
PRODUCT DATA SHEET CHKD: BH APPV: IRS
Biological Properties: Roxul® Stonewool contains no nutrients and therefore provides no basis for growth of fungi, moulds or bacteria, nor does it attract insects, rodents or vermin.
Durability: Roxul® Stonewool mineral wool has been proven in services for over 50 years in all types of exposure and as such will give effective protection for the lifetime of the equipment they insulate.
Compatibility: Roxul® Stonewool mineral wool is compatible with all materials which it is likely to come into contact in normal industrial and building applications.
Environment: Roxul® Stonewool mineral wool presents a very effective ecological profile in all elements of manufacture, recycling use, service life and energy efficiency of material. No CFC’s or HCFC’s are used in its manufacture.
Installation Instructions: 1. Party Wall Fire Stop must be fitted as a rectangular piece, accurately butt jointed and compressed by at least 5% vertically in thickness.
2. Party Wall Fire Stop must be fitted to give a tight and accurate fit, closely following the profile of the gap.
3. Appraisal documents permit 1 or 2 layers to be used. Single layer fire stopping will always be preferred. However, double layer methods are acceptable where there is no other practical alternative. If used, 2 layers should be installed simultaneously.
4. Expansion gaps can be fire-stopped with Fire Stop Fire Damper Strip materials. The compression levels should be observed in due regard to expansion movement.
5. Installers may find simple smooth ‘slip-plates’ of benefit in installing Party Wall Fire Stop materials over rough surfaces.
RHINO ROCKWOOL FIRE SEAL BATTS
AUSTRALASIAN INSULATION SUPPLIES
Product: Roxul ® Stonewool P.D.S
Type: FIRE PROTECTION 39
Name: Page 4 of 4
REVISION: 2
DATE OF ISSUE: April ‘04
PRODUCT DATA SHEET CHKD: BH APPV: IRS
• Over 50 years of extensive health research on Stonewool products in Europe has resulted in the scientific conclusion that there are no long term health problems from using Stonewool.
• In March 1995 the UK Health and Safety Executive concluded that Stonewool should not be classified as a potential carcinogen.
• Under note Q of the National Occupational health and Safety Commission (NOHSC) publication “List of Designated Hazardous Substances” (NOHSC; 1005-1999) the classification of NON-CARCINOGENIC is to apply.
• Under the European Union Criteria set out in 67/548/EEC a classification of CARC, Cat O applies, ie; ”Not classifiable for carcinogenicity.”
• Under World Health Organisation (WHO) and its Monographs Programme of the International Agency for Research on Cancer (IARC) it has been concluded that, Stonewools are now considered not classifiable as to carcinogenicity to humans (Group 3),
It recommended that for the handling and installation of Roxul® Stonewool the internationally recognized Material Safety Data Sheet be followed; These are readily available from Australasian Insulation Supplies Pty Ltd.
For further information and technical advice on insulation contact:
Health & Safety
RHINO ROCKWOOL FIRE SEAL BATTS
Rhino Rockwool Fire Seal Batts are NOT CLASSIFIED as HAZARDOUS according to
NOHSC criteria as a consequence of the following events and conclusions about the health effects of long term occupation exposure to mineral wool insulation products.
Address: 293 Earnshaw Road, Northgate QLD 4013Postal Address: PO Box 14, Northgate QLD 4013
Ph: (07) 3246 2200 Fax: (07) 3219 6833
AUSTRALASIAN INSULATION SUPPLIES
Section 9ACCESSORIES
• Safety Mesh
Galvanised wire with tensile strength of 450mpa. Safety Mesh can be used on Factories, Warehouses, Shopping Centres, Schools, office Blocks, Sheds and much more.
• Roof Razor
Wide enough to walk on, the fastest spacer to install. Pre-loaded screws. Suitable for all roof sheet profiles including pierced and concealed fix. Suitable for glass wool or polyester 1200mm wide to suit the blanket. Cyclonic version available with higher screw pull-out capacity. Made in Australia, patent pending design.
by THOR BUILDING PRODUCTS
Information Technology Solutions
PRODUCT INFORMATION
Original roo�ng mesh that was developed and tested to provide the industry standard described in the AS/NZS 4389 and ALL State Code of Practices for Safe Working on Roofs.
SAFETY MESH
Proudly Manufactured by
Thor Building Products P/L
1300 880 828(07) 3219 6833
293 EARNSHAW ROADPO BOX 14
NORTHGATE QLD 4013
WWW.THORBUILDING.COM.AU
Can be used on the following roofs:
Factories
Shopping Centres
Hospitals/Aged Care Facilities
Sheds
Warehouses
Schools
Office Block
Roofing Mesh consists of 2mm galvanised wire with a tensile strength
exceeding 450mpa. The longitudinal wires are spaced at 150mm centres with
cross wires spaced at 300mm centres. The rolls are available either 1800mm,
2250mm or 2400mm wide and are supplied in standard 50metre rolls or cut to
the length of the roof run.
The product is also available PVC-coated for use in corrosive environments.
Original roofing mesh that was developed and tested to provide the industry standard described in the AS/NZS 4389 and ALL State Code of Practices for Safe Working on Roofs.
Specifications:
1800 WIDE 2250 WIDE 2400 WIDE PVC1800
Weight per 50m 24kg 29kg 31kg 28kg
Weight per metre 0.48kg 0.58kg 0.62kg 0.56kg
Sqm per roll 90 112.5 120 90
Sqm with one lap 82.5 105 112.5 82.5
Sqm with double lap 75 97.5 105 75
50m rolls per pallet 25 25 25 16
Information Technology Solutions
PRODUCT INFORMATION
Raise the roof or create an open space between two planes with the Roof Razor.
ROOF RAZOR
Proudly Manufactured by
Thor Building Products P/L
1300 880 828(07) 3219 6833
293 EARNSHAW ROADPO BOX 14
NORTHGATE QLD 4013
WWW.THORBUILDING.COM.AU
The unique design of the legs means that the screws not only come pre-loaded, but are also encased within the legs. The legs guide the fixings to the purlinand stop the polyester fibres from spinning or being entangled around the screws.
Key advantages of the Roof Razor system
68.4mm surface width
Horizontally opposed fixing points provide a strong and
Compatible with all brands of roofing clips, and all roofing profiles
One piece system
1200mm length to suit building blanket width
Suitable for walling
Supplied fully assembled and pre-loaded with screws
Tiny contact areas reduce loss of R-value to less than 1%
Legs are sharp enough to cut throughtthe wool like a knife
THERMAL PERFORMANCE
Voids create thermal bridging
No Fully compressed wool, total loss of R-Value less than 1%
Significantlyincreased R-value when using the Roof Razor System
... and it won't loosen over time
Raise the roof or create an open space between two planes with the Roof Razor. Suitable for roofing, walling and flooring this versatile and robust solution has endless possibilities. The unique design will also slice through glass wool insulation allowing it to recover to its full nominal thickness.
by THOR BUILDING PRODUCTS