RFQ and Purchase Order Specification Work Sheets
Section: R406.016Date: 3-6-2015Supersedes: 8-1-2013 Page 1
Please complete all information fields in this worksheet and submit with your RFQ (Request For Quote) or Purchase Order. The use of these worksheets has proven to greatly decrease Engineering time and virtually eliminate specification errors.
Eye-Hye SmartLevel
Order Specification Sheet for Reliance 10 Probe Electrolev
ColumnMust accompany P.O with all fields
completed
Customer: Contact Name:
Project Name: E-mail:
Project Location: Phone Number:
Date: RFQ/P.O. Number:
Design Pressure:
Design Temperature:
Model No.:
STEAM & WATER CONNS.(1” MSW Pipe Projection is standard)
Steam & Water Connections (other than standard – specify size & type Req'd.):
Male Socket Weld (Pipe Projection):
Female Socket Weld:
Flange Size:
Flange Class:
Flange Face:
Other (please specify):
ELECTROLEV COLUMN REQUIRED INFORMATION
DRAIN CONN.(1/2” FSW is standard with Electrolev Column)
Drain Connection (other than standard – specify size & type Req'd.):
Female Socket Weld:
Male Socket Weld (Pipe Projection):
Flange Size:
Flange Class:
Flange Face:
Other (please specify):
OPTIONS REQUIRED
Vent connection (Specify size & type):
Integral junction box: NEMA 4 NEMA 4X
Additional probe wire (specify length required):
FlexPak Insulation Jacket:
Purge Controls for Hazardous Area:
Other (please specify):
Section: R406.017Date: 3-6-2015Supersedes: 8-1-13 Page 2
Z Brazed ProbeF Brazed Probe
FSB Brazed Probe
E
1
2
3
4
5
6
7
8
9
10
A
BC
D
F S
TEAM
AN
D W
ATER
CEN
TERS
G B
OD
Y O
VERA
LL (
TO B
E CA
LCU
LATE
D A
T TH
E FA
CTO
RY)
1/2" FSW DRAINCONNECTION
6
Additional notes:
REQUIRED DIMENSIONAL INFORMATION
A
B
C
D
E
F
G -----
PROBE DISTANCE FROM NWL
10
9
8
7
6
5
4
3
2
1
DIMENSIONAL NOTES:1) MINIMUM DISTANCE BETWEEN PROBES IS 1” (25.4mm)2) MINIMUM “E” DIMENSION IS 1” (25.4mm)3) MINIMUM DISTANCE BETWEEN TOP PROBE AND STEAM
CONNECTION (UPPER CONNECTION) IS 1” (25.4mm)
Note: This illustration shows Probe #5 as NWL. However, this location could vary depending on the application. Please signify NWL as “0” in the applicable box
NWL
Section: R406.017Date: 3-6-2015Supersedes: 8-1-13Page 3
NOTE: Select numbers for all required fields (in YELLOW).
Control UnitNumber of level detection modules (= to the # of probes in the Electrolev Column)Number of probes to be between 6 and 24
Enclosure Type:1 = NEMA 4 Outdoor (IP66) - Standard Enclosure2 = NEMA 4X Outdoor Stainless Steel (IP66)3 = NEMA 4X Outdoor Stainless Steel (IP66) with full viewing window4 = NEMA 4 Outdoor (IP66) with indicator view5 = NEMA 4X Outdoor Stainless Steel (IP66) with indicator view6 = NEMA 4 Outdoor (IP66) - Standard Enclosure: 13 - 24 probe models7 = NEMA 4X Outdoor Stainless Steel (IP66): 13 - 24 probe models8 = NEMA 4X Outdoor Stainless Steel (IP66) with full viewing window: 13 - 24 probe models9 = NEMA 4 Outdoor (IP66) with indicator view: 13 - 24 probe models10 = NEMA 4X Outdoor Stainless Steel (IP66) with indicator view: 13 - 24 probe models11 = NEMA 7/4X Explosionproof and weatherproof12 = NEMA 7/4X Explosionproof and weatherproof: 13 - 24 probe modelsNOTE: Full viewing window is only available on NEMA 4X option
Power Supplies:1 = Single Internal Power Supply for 120/240 VAC Power Sources (standard)2 = Dual Internal Power Supply for 120/240 VAC Power Sources3 = CE Kit with Single Internal Power Supply for 120/240 VAC Power Source4 = CE Kit with Dual Internal Power Supply for 120/240 VAC Power Source
Relay Output Module:0 = No additional modules (see note)1 = One additional 6 channel Relay Module (not available when the 4-20mA card is selected)2 = One 4-20mA Output Module (not available when option #1 is selected)3 = Two additional 6 channel Relay Modules (only with 13 - 24 probe models)4 = Three additional 6 channel Relay Modules (only with 13 - 24 probe models)5 = One 4-20mA Output Module and one additional 6 channel Relay Module (only with 13 - 24 probe models)6 = One 4-20mA Output Module and two additional 6 channel Relay Module (only with 13 - 24 probe models)7 = One 4-20mA Output Module and three additional 6 channel Relay Module (only with 13 - 24 probe models)NOTE: All control units come standard with one 6 channel relay module)
Medium Indicator0 = None1 = One Medium Indicator for panel mounting2 = Two Medium Indicators for panel mounting3 = One Medium Indicator and one with a NEMA 4 Enclosure for local indication4 = One Medium Indicator and one with a NEMA 4X S.S. Enclosure for local indication
Small Indicator0 = None1 = One Small Indicator for panel mounting2 = One Small Indicator mounted on the enclosure door (not available with NEMA 7 Encl.)3 = One Small Indicator with a NEMA 4 Enclosure for local indication4 = One Small Indicator with a NEMA 4X S.S. Enclosure for local indication
SmartLevel Control Unit and Indicator Selection Sheet
Special Options0 = NoneS = Defined below (Must be specified on the Purchase Order)
Control UnitModel No.: RSC
Instructions: Blocks that are YELLOW require a selection to be made. Hit the TAB key to go to the next required field.Save the sheet with a new file name when complete.
Notes and Special Options:
FSeveraTypewritten TextNote: Both NEMA 4 and NEMA 4X enclosures are classified as IP66. Specify NEMA 4X Stainless Steel Enclosures when some degree of corrosion resistance is required.
FSeveraTypewritten Text
Notes and Special Options 1: Notes and Special Options 2: Notes and Special Options 3: Notes and Special Options 4: Notes and Special Options 5: Number of level detection modules to the of probes in the Electrolev Column: Enclosure Type: Power Supplies: Relay Output Module: Medium Indicator: Text1: 0Small Indicator: Special Options: Customer: Contact Name: Project Name: Email: Project Location: Phone Number: Date: RFQPO Number: Design Pressure: Design Temperature: Pipe Projection: Model No: Female Socket Weld: Flange Size: Flange Class: Flange Face: specify: Check Box11: OffCheck Box3: OffCheck Box12: Offsize type: Check Box4: OffCheck Box5: OffFemale Socket Weld_2: Pipe Projection_2: specify length required: Flange Size_2: Check Box6: OffFlange Class_2: Flange Face_2: Check Box7: OffOther please specify: Other please specify 1: Other please specify 2: 10: 9: 8: 7: 6_2: 5: 4: 3: 2: 1: A: B: C: D: E: F: Additional notes 1: Additional notes 2: