8

Rexway RMC Conduit & Fittings Catalog

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Rexway RMC Conduit & Fittings Catalog
Page 2: Rexway RMC Conduit & Fittings Catalog
Page 3: Rexway RMC Conduit & Fittings Catalog

M O R E A B O U T

EMI shielding...

REXWAY Rigid Metal Conduit (RMC) is produced to meet the specifications laid out in ANSI C80.1 and UL 6. Manufactured from high strength mild steel strip, REXWAY RMC has undergone extensive mechanical impact testing and is proven to be able to withstand excessive structural abuse. Ultimately this is the heaviest and thickest walled ANSI standard conduit Insteel produces.

REXWAY RMC is hot dipped galvanised inside and out to provide superior corrosion protection. Its clean even interior reduces friction between the wall of the conduits and the wires, providing easy wire pulling during installation.

Additionally, REXWAY RMC couplings, elbows and nipples are available right through to 6” providing you with the complete supply solution.

• Manufactured to meet the specifications laid out in ANSI C80.1 and UL 6.

• Highest strength steel offers longevity and value under the most demanding environments.

• The heaviest and thickest walled conduits, yet possesses superior ductility for cutting, bending and welding.

• Clean even interior facilitates smooth continuous raceways for easy wire pulling.

• Hot dipped galvanised widely regarded as the most superior galvanising protection against corrosion.

• Supplied precision threaded, with a color coded thread protector on one end and a coupling on the other.

• REXWAY RMC is supplied in standard length of 10ft (3.05m). Available from 1/2” to 6”.

• REXWAY RMC Couplings, elbows and nipples are available from 1/2“ to 6”.

REXWAY Rigid Metal Conduit

REXWAY RMC nipples are made from the same grade of tubing as the conduit lengths, and threaded according to the same specifications. Trade sizes are available throughout our range of common size from 1/2” to 6”.

EMI from everyday electrical distribution systems cause problems to today’s sensitive equipment. From distortion of images on computers, to disruption of vital communication links, such problems can impact from the irritating to the catastrophic! Steel conduit cable management systems “are the most effective” in reducing EMI levels for encased power-distribution circuits, reducing the field levels by up to 95% ** (in 60-Hzl systems). While steel may not be the least expensive type of conduit available, it is the most cost effective approach in the long term, for controlling the impact of EMI.

For just this reason, the Federal Aviation Administration (FAA) has recommended the use of steel conduit to overcome problems at locations where control, communications & airfield-lighting cable either cross or run parallel to each other. (**Research carried out by Georgia Institute of Technology, USA sponsored by the Steel Tube Institute (STI)).

P R O D U C T

FEATURES

Nominal size(inch)

1/23/41

1-1/41-1/2

22-1/2

33-1/2

456

Item Code

RX-RE90DSR050HRX-RE90DSR075HRX-RE90DSR100HRX-RE90DSR125HRX-RE90DSR150HRX-RE90DSR200HRX-RE90DSR250HRX-RE90DSR300HRX-RE90DSR350HRX-RE90DSR400HRX-RE90DSR500HRX-RE90DSR600H

0.8401.0501.3151.6601.9002.3752.8753.5004.0004.5005.5636.625

44-1/25-3/47-1/48-1/49-1/2

10-1/21315162430

1-1/21-1/21-7/8

2223

3-1/83-1/43-3/83-5/83-3/4

External Diameter (inch)

Radius, R(inch)

Straight Length,Ls at each end

(inch)

Rigid Metal Conduit 90° Standard Radius Elbow

Rigid Metal Conduit Nipple (1/2” to 6”)

Rigid Metal ConduitRigid Metal Conduitmaximummaximum

mechanicalmechanicalprotectionprotection

Rigid Metal Conduitmaximum

mechanicalprotection

Page 4: Rexway RMC Conduit & Fittings Catalog

Item CodeNorminal

WallThickness

(mm)

Approx.Weight per Length with

Coupling(kgs)

Trade Size

RX-R050HRX-R075HRX-R100HRX-R125HRX-R150HRX-R200HRX-R250HRX-R300HRX-R350HRX-R400HRX-R500HRX-R600H

mminch

1/23/41

1-1/41-1/2

22-1/2

33-1/2

456

162127354153637891

103129155

21.326.733.442.248.360.373.088.9101.6114.3141.3168.3

2.602.703.203.403.503.704.905.205.505.706.206.80

3.724.947.309.89

11.9315.8725.3532.9739.9146.7163.4983.45

OutsideDiameter

(mm)

Rigid Metal Conduit

Outside Diameter Tolerances:• For trade size 1/2” (16mm) through 1-1/2” (41mm): +/-0.015 in (+/-0.38mm)• For trade size 2” (53mm) through 6” (155mm): +/-1%

M O R E A B O U T

Hot Dipped Galvanising... Galvanising may be defined as the process by which zinc is metallurgical bonded over an iron or steel substrate to provide protection to the base metal. The zinc coating provides protection to the substrate in two distinct ways:

• By shielding the base metal to the atmosphere. • By providing anodic protection to the base metal.

Pickling & Rinsing

Application A d v a n t a g e s

REXWAY RMC is manufactured to ensure absolute functionality in a variety of demanding environments. Be it indoor or outdoor, exposed or concealed, dry or wet locations. Or even in hazardous locations when in accordance with National Electric Code (NEC) Article 344.

• Reusability for future additions or replacement of circuits.• Non-combustibility reduces hazards from fire.• Built-in grounding capabilities eliminate the need for supplemental grounding conductors. • Steel conduit acts as an Electromagnetic Interference (EMI) shield!

L2

EO

L4

All REXWAY RMC is hot dipped galvanised by dipping the cleaned and pickled bare steel conduit pipes into a molten zinc bath, kept at a consistent temperature of above 430°C. After exiting the zinc bath, an application of chromate conversion coating is added. Put simply, the zinc protects the steel and the chromate protects the zinc!

Micrograph of hot dipped galvanised coating

Zinc

Zinc-iron alloys

Steel

50μm

TradeSize

(inch) Max.(mm)

Min.(mm)

Max.(mm)

Min.(mm)

20.6826.0132.5941.3547.4559.5171.8387.71

100.40113.10140.10167.10

20.3525.6832.1840.9447.0459.1171.2787.1599.85

112.60139.60166.60

21.2926.6233.0241.7847.8859.9472.6488.52

101.20113.90141.70168.90

20.2725.6032.0040.7746.8658.9371.1287.0099.70

112.40140.20167.40

Minimum AcceptableLength ofCoupling

(mm)

Pitch Diameter Chamfer Diameter

1/23/41

1-1/41-1/2

22-1/2

33-1/2

456

ItemCode

RX-RC050HRX-RC075HRX-RC100HRX-RC125HRX-RC150HRX-RC200HRX-RC250HRX-RC300HRX-RC350HRX-RC400HRX-RC500HRX-RC600H

41.341.750.051.652.454.081.084.186.589.3

100.4108.0

Rigid Metal Conduit Coupling

REXWAY Rigid Metal Conduit REXWAY Rigid Metal Conduit

Page 5: Rexway RMC Conduit & Fittings Catalog

Item CodeNorminal

WallThickness

(mm)

Approx.Weight per Length with

Coupling(kgs)

Trade Size

RX-R050HRX-R075HRX-R100HRX-R125HRX-R150HRX-R200HRX-R250HRX-R300HRX-R350HRX-R400HRX-R500HRX-R600H

mminch

1/23/41

1-1/41-1/2

22-1/2

33-1/2

456

162127354153637891

103129155

21.326.733.442.248.360.373.088.9101.6114.3141.3168.3

2.602.703.203.403.503.704.905.205.505.706.206.80

3.724.947.309.89

11.9315.8725.3532.9739.9146.7163.4983.45

OutsideDiameter

(mm)

Rigid Metal Conduit

Outside Diameter Tolerances:• For trade size 1/2” (16mm) through 1-1/2” (41mm): +/-0.015 in (+/-0.38mm)• For trade size 2” (53mm) through 6” (155mm): +/-1%

M O R E A B O U T

Hot Dipped Galvanising... Galvanising may be defined as the process by which zinc is metallurgical bonded over an iron or steel substrate to provide protection to the base metal. The zinc coating provides protection to the substrate in two distinct ways:

• By shielding the base metal to the atmosphere. • By providing anodic protection to the base metal.

Pickling & Rinsing

Application A d v a n t a g e s

REXWAY RMC is manufactured to ensure absolute functionality in a variety of demanding environments. Be it indoor or outdoor, exposed or concealed, dry or wet locations. Or even in hazardous locations when in accordance with National Electric Code (NEC) Article 344.

• Reusability for future additions or replacement of circuits.• Non-combustibility reduces hazards from fire.• Built-in grounding capabilities eliminate the need for supplemental grounding conductors. • Steel conduit acts as an Electromagnetic Interference (EMI) shield!

L2

EO

L4

All REXWAY RMC is hot dipped galvanised by dipping the cleaned and pickled bare steel conduit pipes into a molten zinc bath, kept at a consistent temperature of above 430°C. After exiting the zinc bath, an application of chromate conversion coating is added. Put simply, the zinc protects the steel and the chromate protects the zinc!

Micrograph of hot dipped galvanised coating

Zinc

Zinc-iron alloys

Steel

50μm

TradeSize

(inch) Max.(mm)

Min.(mm)

Max.(mm)

Min.(mm)

20.6826.0132.5941.3547.4559.5171.8387.71

100.40113.10140.10167.10

20.3525.6832.1840.9447.0459.1171.2787.1599.85

112.60139.60166.60

21.2926.6233.0241.7847.8859.9472.6488.52

101.20113.90141.70168.90

20.2725.6032.0040.7746.8658.9371.1287.0099.70

112.40140.20167.40

Minimum AcceptableLength ofCoupling

(mm)

Pitch Diameter Chamfer Diameter

1/23/41

1-1/41-1/2

22-1/2

33-1/2

456

ItemCode

RX-RC050HRX-RC075HRX-RC100HRX-RC125HRX-RC150HRX-RC200HRX-RC250HRX-RC300HRX-RC350HRX-RC400HRX-RC500HRX-RC600H

41.341.750.051.652.454.081.084.186.589.3

100.4108.0

Rigid Metal Conduit Coupling

REXWAY Rigid Metal Conduit REXWAY Rigid Metal Conduit

Page 6: Rexway RMC Conduit & Fittings Catalog

M O R E A B O U T

EMI shielding...

REXWAY Rigid Metal Conduit (RMC) is produced to meet the specifications laid out in ANSI C80.1 and UL 6. Manufactured from high strength mild steel strip, REXWAY RMC has undergone extensive mechanical impact testing and is proven to be able to withstand excessive structural abuse. Ultimately this is the heaviest and thickest walled ANSI standard conduit Insteel produces.

REXWAY RMC is hot dipped galvanised inside and out to provide superior corrosion protection. Its clean even interior reduces friction between the wall of the conduits and the wires, providing easy wire pulling during installation.

Additionally, REXWAY RMC couplings, elbows and nipples are available right through to 6” providing you with the complete supply solution.

• Manufactured to meet the specifications laid out in ANSI C80.1 and UL 6.

• Highest strength steel offers longevity and value under the most demanding environments.

• The heaviest and thickest walled conduits, yet possesses superior ductility for cutting, bending and welding.

• Clean even interior facilitates smooth continuous raceways for easy wire pulling.

• Hot dipped galvanised widely regarded as the most superior galvanising protection against corrosion.

• Supplied precision threaded, with a color coded thread protector on one end and a coupling on the other.

• REXWAY RMC is supplied in standard length of 10ft (3.05m). Available from 1/2” to 6”.

• REXWAY RMC Couplings, elbows and nipples are available from 1/2“ to 6”.

REXWAY Rigid Metal Conduit

REXWAY RMC nipples are made from the same grade of tubing as the conduit lengths, and threaded according to the same specifications. Trade sizes are available throughout our range of common size from 1/2” to 6”.

EMI from everyday electrical distribution systems cause problems to today’s sensitive equipment. From distortion of images on computers, to disruption of vital communication links, such problems can impact from the irritating to the catastrophic! Steel conduit cable management systems “are the most effective” in reducing EMI levels for encased power-distribution circuits, reducing the field levels by up to 95% ** (in 60-Hzl systems). While steel may not be the least expensive type of conduit available, it is the most cost effective approach in the long term, for controlling the impact of EMI.

For just this reason, the Federal Aviation Administration (FAA) has recommended the use of steel conduit to overcome problems at locations where control, communications & airfield-lighting cable either cross or run parallel to each other. (**Research carried out by Georgia Institute of Technology, USA sponsored by the Steel Tube Institute (STI)).

P R O D U C T

FEATURES

Nominal size(inch)

1/23/41

1-1/41-1/2

22-1/2

33-1/2

456

Item Code

RX-RE90DSR050HRX-RE90DSR075HRX-RE90DSR100HRX-RE90DSR125HRX-RE90DSR150HRX-RE90DSR200HRX-RE90DSR250HRX-RE90DSR300HRX-RE90DSR350HRX-RE90DSR400HRX-RE90DSR500HRX-RE90DSR600H

0.8401.0501.3151.6601.9002.3752.8753.5004.0004.5005.5636.625

44-1/25-3/47-1/48-1/49-1/2

10-1/21315162430

1-1/21-1/21-7/8

2223

3-1/83-1/43-3/83-5/83-3/4

External Diameter (inch)

Radius, R(inch)

Straight Length,Ls at each end

(inch)

Rigid Metal Conduit 90° Standard Radius Elbow

Rigid Metal Conduit Nipple (1/2” to 6”)

Rigid Metal ConduitRigid Metal Conduitmaximummaximum

mechanicalmechanicalprotectionprotection

Rigid Metal Conduitmaximum

mechanicalprotection

Page 7: Rexway RMC Conduit & Fittings Catalog
Page 8: Rexway RMC Conduit & Fittings Catalog