Upload
others
View
3
Download
0
Embed Size (px)
Citation preview
Micro Motion Gas Density Meter
REVOLUTIONIZE YOUR GAS DENSITY AND PURITY MEASUREMENT TECHNOLOGY
INTRODUCING EMERSON’S MICRO MOTION® GAS DENSITY METER
Density Measurement with Reliability and Confidence
The combination of our industry-leading technology, wide breadth of products, unparalleled application expertise and customer support allows us to deliver unbeatable performance and value, time and time again. The Micro Motion Gas Density Meter Delivers:
Superior Measurement Capabilities
• An innovative sensor unaffected by process or compositional changes that provides the best, real-world measurement performance
• The tightest density resolution and accuracy available (±0.1% reading over 1-400 kg/m3 range)
A World-Class Leading Electronics Platform
• Local display and user interface allows for simplified device management, minimizing maintenance requirements
• Simple integration into DCS, PLC, and flow computers (Frequency/Time Period, Analog 4-20mA, HART®, Modbus RS485 and WirelessHART TM)
• Revolutionary device diagnostics and verification methods
Accredited Density Measurement
• State-of-the-art IEC/ISO17025 accredited, traceable density calibrations
• Compliant to national and international standards
Our Gas Density Meter (GDM) delivers fast-response
online gas density and purity measurements. Designed
for fiscal metering, this rugged and reliable meter raises
the standard for online density measurement of gases
such as fuel gas, syngas, hydrogen and natural gas
mixtures. The meter enhances your custody transfer,
purity and blending measurement confidence by
leveraging best-in-class performance and leading
accredited calibration facilities.
Meter DiagnosticsBuilt-in diagnostics for real-time monitoring and automated meter verification systems
Application-Specific ConfigurationsAutomatic, application-specific measurement and output configurations ensure simple set-up and commissioning
Unrivalled Density Performance A choice of installation options for replacement and upgrade solutions give you the performance you need
InterconnectivityIntegral HART I/O allows direct input of external temperature, pressure and flow measurements for enhanced outputs
STATUS
SCROLL SELECT
Density
Base Density
Specific Gravity, Molecular weight
%H2 Purity
User defined calculations
GDM Compatible Devices
Vortex Flow Pressure
Mass Flow
Base Density
Gas Specific Gravity
Molecular Weight
BASIC version:TPS, temperature
ADVANCED version:TPS, mA, RS-485
Time period signal(TPS), temperature
PRODUCT HIGHLIGHTS
RUG
GED
& R
ELIABLE
Oil & Gas Pipeline & Terminals • Natural Gas Fiscal and Custody Transfer
Minimize exposure and gain/loss uncertainty
• Measurement Standards Adheres to national & international standards (AGA3, ISO5167)
Refining & Petrochem Fuel Gas & Hydrogen Measurement • Enhanced Refining Efficiencies
Hydrogen purity indication for improved cracking yields and catalyst protection
• Combustion Control Fuel gas density input to air/fuel ratio control enables stable steam production
Power Generation • Turbine Generator Cooling
Hydrogen purity indication improves cooling efficiency and minimizes windage losses
• Operation and Maintenance Expense Reduced fuel costs through efficient peak shaving and combustion fuel management
KEY APPLICATIONS
STATUS
SCROLL SELECT
STATUS
SCROLL SELECT
STATUS
SCROLL SELECT
YOUR SOLUTION FOR THE MOST DEMANDING PROCESS APPLICATIONS
MICRO MOTION
For over 30 years, Emerson’s Micro Motion
has been a technology leader delivering the
most precise flow, density and concentration
measurement devices for fiscal applications,
process control and process monitoring.
Our passion for solving flow and density
measurement challenges is proven through
the highly accurate and unbeatable
performance of our devices.
Fork Density Meter
Direct InsertionDensity Meter
Gas Density Meter
Fiscal GasDensity Meter
Specific Gravity Meter
Gas Specific Gravity/BTU Meter
Fork Viscosity Meter
Multi-VariableViscosity Meter
Heavy Fuel Viscosity Meter
Multi-Variable Marine & PowerHFO Viscosity Meter
Compact Density Meter
Peak PerformancePrecision Density Meter
MC-001803 Rev C 04/2019
For more information, please visit: www.Emerson.com/density
©2019 Micro Motion, Inc. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. Micro Motion, ELITE, ProLink, MVD and MVD Direct Connect marks are marks of one of the Emerson family of companies. All other marks are property of their respective owners.
Emerson Automation SolutionsAmericas7070 Winchester Circle Boulder, Colorado USA 80301 www.MicroMotion.comwww.Rosemount.comT: +1 800 522 6277 T: +1 (303) 527 5200F: +1 (303) 530 8459
Mexico T: 52 55 5809 5300Argentina T: 54 11 4837 7000Brazil T: 55 15 3413 8000Chile T: 56 2 2928 4800
Emerson Automation SolutionsEurope/Middle EastCentral & Eastern Europe T: +41 41 7686 111Dubai T: +971 4 811 8100Abu Dhabi T: +971 2 697 2000 France T: 0800 917 901Germany T: +49 (0) 2173 3348 0Italy T: 8008 77334The Netherlands T: +31 (0) 70 413 666Belgium T: +32 2 716 77 11Spain T: +34 913 586 000U.K. T: 0870 240 1978Russia/CIS T: +7 495 981 9811
Emerson Automation SolutionsAsia Pacific Australia T: (61) 3 9721 0200China T: (86) 21 2892 9000India T: (91) 22 6662 0566Japan T: (81) 3 5769 6803South Korea T: (82) 31 8034 0000Singapore T: (65) 6363 7766
Measuring Range 1-400 kg/m3 (0.001-0.4 g/cc)
Density Accuracy ±0.1% of reading
Density Repeatability ±0.02% of reading
Temperature Accuracy BS1904, DIN 43760 Class ‘A’ (±0.15 ± 0.002 X T)°C
Accreditation & Standards ISO17025, NAMUR, NACE (pressure retaining parts), AGA3, ISO5167
Safety Approvals ATEX, CSA, IECEx (Intrinsically-safe)
Display Two-line, LCD screen, Optical switch confi guration
Outputs Standard : Time Period, 4-20mA, HART, Modbus RS-485
Optional : WirelessHARTTM
Protection Class Ingress Protection : IP66/67, NEMA4 EMC compliant with EN61326
Dimensions 376 mm (h) x 125 mm (w) x 163 mm (d)
Weight (Typical) 5 kg (11 lbs)
Gas Density Meter Specifications
DEN
SITY
& PU
RIT
Y