5
DO NOT DRILL OVERSIZE DO NOT TORCH CUT HOLE INCH FOR ACCURATE FLOW MEASUREMENT THE CORRECT HOLE SIZE IN PIPE MUST BE: (19mm) 3/4 NOTICE ® SENSOR SIZE 1 (SEE TABLE/SHT 2) RF MOUNTING FLANGE & WELD FTG. (SEE TABLE/SHEET 2 FOR SIZES) STUDS, NUTS & GASKET 3 RF SENSOR FLANGE (SEE TABLE/SHT 2 FOR SIZE) 3 OSS SIZE ID ODF ODH WALL ODP FLOW INTEGRAL MOUNT HEAD OPTION FLOW INTEGRAL MOUNT WITH OPPOSITE SIDE SUPPORT LOW PRESSURE INSTRUMENT VALVE HIGH PRESSURE INSTRUMENT VALVE LOCKING PIN EQUALIZER VALVE VALVE BONNET ASSY OPTIONAL RTD PORT (150# THRU 600# ANSI SHOWN) MAX. 9.00 (228.6) MAX. 5.50 (19.7) DIA. (SEE TABLE/SHT 2) 'O' DIMENSION DRAWING, MODEL 485 ANNUBAR FLOWMETER (3051SFA, 3051CFA 2051CFA, 3095MFA) SENSOR SIZE 1 FLANGED 150# - 2500# ANSI DR. 4/1/05 M.MONTGOMERY 6/15/05 jpaylor NONE SIZE SCALE: A TITLE 00485-1011 SHEET BOULDER, COLORADO DRAWING NO. 1 OF 5 REVISIONS AF REV ADDED 3051CFx AND 2051CFx DESCRIPTION CHG.NO. DSI1003150 JR APP'D 02/15/10 DATE APPROVAL SPECIALS TAGGING DRAWING *ALL DIMENSIONS ARE NOMINAL AND ARE FOR REFERENCE ONLY *UNLESS OTHERWISE SPECIFIED DIMENSIONS IN INCHES (MM) TYPE I

REVISIONS APP'D ADDED 3051CFx AND 2051CFx 3 ......FSCM.NO. 5 5 00485-1011 NONE BOULDER, COLORADO Title Rosemount 485 ANNUBAR Flowmeter (3051SFA, 3051CFA 2051CFA,3095MFA) Sensor Size

  • Upload
    others

  • View
    11

  • Download
    0

Embed Size (px)

Citation preview

Page 1: REVISIONS APP'D ADDED 3051CFx AND 2051CFx 3 ......FSCM.NO. 5 5 00485-1011 NONE BOULDER, COLORADO Title Rosemount 485 ANNUBAR Flowmeter (3051SFA, 3051CFA 2051CFA,3095MFA) Sensor Size

DO NOT DRILL OVERSIZEDO NOT TORCH CUT HOLE

INCH

FOR ACCURATE FLOW MEASUREMENTTHE CORRECT HOLE SIZE IN PIPE MUST BE:

(19mm)3/4

NOTICE

®

SENSOR SIZE 1

(SEE TABLE/SHT 2)RF MOUNTING FLANGE & WELD FTG.(SEE TABLE/SHEET 2 FOR SIZES)STUDS, NUTS & GASKET3

RF SENSOR FLANGE(SEE TABLE/SHT 2 FOR SIZE)

3

OSS SIZE

ID

ODFODH

WALL

ODP

FLO

W

INTEGRAL MOUNT HEAD OPTION

FLOW

INTEGRAL MOUNT WITHOPPOSITE SIDE SUPPORT

LOW PRESSUREINSTRUMENT VALVE

HIGH PRESSUREINSTRUMENT VALVE

LOCKING PIN

EQUALIZER VALVE

VALVE BONNET ASSY

OPTIONAL RTD PORT

(150# THRU 600# ANSI SHOWN)

MAX.

9.00(228.6)

MAX.

5.50(19.7)

DIA. (SEE TABLE/SHT 2)

'O'

DIMENSION DRAWING, MODEL 485 ANNUBAR FLOWMETER (3051SFA, 3051CFA 2051CFA, 3095MFA) SENSOR SIZE 1 FLANGED 150# - 2500# ANSI

DR. 4/1/05

M.MONTGOMERY 6/15/05

jpaylor

NONE

SIZE

SCALE:

A

TITLE

00485-1011SHEET

BOULDER, COLORADO

DRAWING NO.

1 OF 5

REVISIONS

AF

REV

ADDED 3051CFx AND 2051CFx

DESCRIPTION CHG.NO.

DSI1003150 JR

APP'D

02/15/10

DATE

APPROVAL

SPECIALS

TAGGING

DRAWING

*ALL DIMENSIONS ARE NOMINALAND ARE FOR REFERENCE ONLY

*UNLESS OTHERWISE SPECIFIEDDIMENSIONS IN INCHES (MM)

TYPE I

Page 2: REVISIONS APP'D ADDED 3051CFx AND 2051CFx 3 ......FSCM.NO. 5 5 00485-1011 NONE BOULDER, COLORADO Title Rosemount 485 ANNUBAR Flowmeter (3051SFA, 3051CFA 2051CFA,3095MFA) Sensor Size

®

OPPOSITE SIDE SUPPORT OPTIONS

TIP OPTION 'D'EXTENDED TIP/WELDED

TIP OPTION 'C'EXTENDED TIP/NPT THREADED

ODP

3 OSS SIZE

WELD FTG.

WELDEDOPPOSITE SIDESUPPORT CUP

ODPOSSSIZE

3

NPT THREADEDFTG.

NPT THREADEDOPPOSITE SIDESUPPORT CUP

SIZE

SCALE:

DRAWING NO.

WT. SHEET OF

AFSCM.NO.

2 5

00485-1011NONE

BOULDER, COLORADO

Page 3: REVISIONS APP'D ADDED 3051CFx AND 2051CFx 3 ......FSCM.NO. 5 5 00485-1011 NONE BOULDER, COLORADO Title Rosemount 485 ANNUBAR Flowmeter (3051SFA, 3051CFA 2051CFA,3095MFA) Sensor Size

FLO

W

®

1-1/2". RF MOUNTING FLANGE& WELD FTG. (SEE TABLE/SHT 2 FOR SIZES)

GASKETSSTUDS & NUTS

SENSOR SIZE 1

3 3

RF SENSOR FLANGE(SEE TABLE/SHT 2 FOR SIZES)

ODF + BFT +.125(3,2)

WALL

ID

ODF

ODH

DO NOT DRILL OVERSIZEDO NOT TORCH CUT HOLE

INCH

FOR ACCURATE FLOW MEASUREMENTTHE CORRECT HOLE SIZE IN PIPE MUST BE:

(19mm)3/4

NOTICE

FLANGED OPPOSITESIDE SUPPORT ASSY.

REMOTE MOUNT HEAD OPTION

REMOTE MOUNTFLANGED

OPPOSITE SIDE SUPPORT

ALSO AVAILABLE FOR HIGH PRESSURE APPLICATIONS

HIGH PRESSUREINSTRUMENTCONNECTION

LOW PRESSUREINSTRUMENTCONNECTION

(150# THRU 600# ANSI SHOWN)

SIZE DRAWING NO.

WT.A

FSCM.NO. 00485-1011BOULDER, COLORADO

SHEET: 3 of 5SCALE: 1:1

Page 4: REVISIONS APP'D ADDED 3051CFx AND 2051CFx 3 ......FSCM.NO. 5 5 00485-1011 NONE BOULDER, COLORADO Title Rosemount 485 ANNUBAR Flowmeter (3051SFA, 3051CFA 2051CFA,3095MFA) Sensor Size

®

3051SFA, STD HARDWARE

3051SMV TRANSMITTER

HEIGHT

HIGH PRESSURE INSTRUMENT VALVE

LOW PRESSUREINSTRUMENT VALVE

3051SFA SHOWN

WIDTH

TEMP WIDTH

485/3051SFA/3095MFA INTEGRAL MOUNT HEAD

EQUALIZERVALVE

FLOWMETER HEIGHT WIDTH TEMPWIDTH

2051CFA 7.03[178,5]

5.50[139,7]

10.09[256,3]

3051CFA 7.1(181)

5.67[144,0]

3051SFA 8.53(216.7)

5.67[144,0]

3095MFA 7.1(181)

5.67[144,0]

SIZE DRAWING NO.

WT.A

FSCM.NO. 00485-1011BOULDER, COLORADO

SHEET: 4 of 5SCALE: 1:1

Page 5: REVISIONS APP'D ADDED 3051CFx AND 2051CFx 3 ......FSCM.NO. 5 5 00485-1011 NONE BOULDER, COLORADO Title Rosemount 485 ANNUBAR Flowmeter (3051SFA, 3051CFA 2051CFA,3095MFA) Sensor Size

FLO

W

®

(SEE TABLE/SHT 2 FOR SIZES)

1/2" SW OR NPTPORTS

SENSOR SIZE 1

3

RF MOUNTING FLANGE & WELD FTG. (SEE TABLE/SHT 2 FOR SIZES)STUDS, NUTS & GASKET

RF SENSOR FLANGE (SEE TABLE/SHT 2 FOR SIZE)

ABOVE 600# ANSI SHOWN

OSS SIZE

ODP ODF

ODHID

WALL

DO NOT DRILL OVERSIZEDO NOT TORCH CUT HOLE

INCH

FOR ACCURATE FLOW MEASUREMENTTHE CORRECT HOLE SIZE IN PIPE MUST BE:

(19mm)3/4

NOTICE

FLOW

HIGH PRESSURE,REMOTE MOUNTHEAD OPTION

HI-PRESSURE REMOTE MOUNT WITHOPPOSITE SIDE SUPPORT

HIGH PRESSUREINSTRUMENTCONNECTION

LOW PRESSUREINSTRUMENTCONNECTION

2500# OPPOSITESIDE SUPPORT

900# & ABOVESTYLE HEAD

(900# & ABOVE ANSI SHOWN)

SIZE

SCALE:

DRAWING NO.

WT. SHEET OF

AFSCM.NO.

5 5

00485-1011NONE

BOULDER, COLORADO