48
GE Multilin 1 Revision 2 October 26 th , 2005

Revision 2 October 26 th , 2005

  • Upload
    talen

  • View
    33

  • Download
    0

Embed Size (px)

DESCRIPTION

Revision 2 October 26 th , 2005. Enervista Use Enervista to Simplify Your Workflow Process. Industry-Leading Suite of Software Tools to Manage your Relays and Meters. EnerVista Suite. Easy to Use Monitoring and Data Recording for Small Systems Pre-configured screens for Instant Monitoring - PowerPoint PPT Presentation

Citation preview

Page 1: Revision 2 October 26 th , 2005

GE Multilin1

Revision 2October 26th, 2005

Page 2: Revision 2 October 26 th , 2005

GE Multilin2

Industry-Leading Suite of Software Tools to Manage your Relays and Meters

Enervista Use Enervista to Simplify Your Workflow Process

Page 3: Revision 2 October 26 th , 2005

GE Multilin3

Device Setup & Document Management Toolset Easily configure IEDs from a single Application Create and Edit setting files Offline, or in Real Time Manage your Support Documents & Software Tools Receive Automatic Notification of new updates

Tool for Creating Control Logic, Simulation Testing, and Commissioning Design Logic with Drag-and-Drop ease Real-time feedback of FlexLogic™ states Documentation of Logic Commissioning Procedures and Tools

Troubleshooting and Reporting Tools Single click retrieval of Fault Data Security Audit Report shows details of setting changes Health Report showing status of Protective Devices Track Firmware Configuration changes to GE devices

Easy to Use Monitoring and Data Recording for Small Systems Pre-configured screens for Instant Monitoring Single-Line monitoring Annunciator Alarms Trending Reports Automatic Fault Data Collection

Communications Server OPC/DDE Server Send device data to HMI, DCS, and SCADA systems Contains memory maps for GE Devices and firmware Automatic Fault Data Collection

Energy Coast Allocation and Billing Software Monitor Energy Consumption of parts of a facility Allocate energy costs to various departments Save energy costs via analysis of energy consumption Perform statistical analysis to avoid peak demand surcharges

EnerVista Suite

Page 4: Revision 2 October 26 th , 2005

GE Multilin4

Enervista LaunchpadEasy to use Device Setup & Document Management Toolset

Simplifying Engineering effort required for the configuration of relays and meters

Page 5: Revision 2 October 26 th , 2005

GE Multilin5

10,000+ Users to date

Enervista LaunchpadEasy to use Device Setup & Document Management Toolset

Page 6: Revision 2 October 26 th , 2005

GE Multilin6

• Complete archive of up-to-date documents & software

• Single Application for configuring all devices

• Automatic E-mail Notification on new updates

• Scheduled downloads of all new document and software releases

Enervista LaunchpadEasy to use Device Setup & Document Management Toolset

Page 7: Revision 2 October 26 th , 2005

GE Multilin7

Settings Configuration• Communicate with Multiple relays at the same time• Configure settings both On-Line and Offline• Copy and Pasting settings• Easy to navigate menu tree• Quick connect communications• Common look and feel for all products setup programs

Metering• Status of all inputs and outputs• Real-Time monitoring of Phasor diagrams• Analyzing of Current and Voltage Harmonics• Viewing of Alarms and Relay Front Panel

Troubleshooting• Analyzing of Event Records• Powerful Oscillography COMTRADE Viewer• Real Time Data Logging• Compare relay settings with setting file

Enervista LaunchpadEasy to use Device Setup & Document Management Toolset

Page 8: Revision 2 October 26 th , 2005

GE Multilin8

Multiple-Language Support

Languages Supported in UR setup program:

• English

• French

• Chinese

• Russian

Infrastructure in place to support other languages

Enervista LaunchpadEasy to use Device Setup & Document Management Toolset

Page 9: Revision 2 October 26 th , 2005

GE Multilin9

Tool for Control Logic Creation, Simulation

Testing, & Commissioning

Troubleshooting and Reporting Tools

Enervista Viewpoint

Viewpoint Monitorin

g

Viewpoint Engineer

Viewpoint Maintena

nce

Easy to use Monitoring and Data Recording for Small

Systems(IEC 61850 Option available)

 

Page 10: Revision 2 October 26 th , 2005

GE Multilin10

Viewpoint MonitoringEasy to use Monitoring and Data Recording for Small Systems

Identify Power System Problems and Automatically Gather Fault Data for Troubleshooting

Page 11: Revision 2 October 26 th , 2005

GE Multilin11

SINGLE-LINE MONITORING AND CONTROL

View Single-Line monitoring screens in minutes

TRENDING REPORTS

Historical Record of Monitored Data

PLUG-AND-PLAY MONITORING

Pre-configured screens for instant monitoring

GLOBAL COMTRADE VIEWER

View Waveforms Recorded From your Devices

AUTOMATIC EVENT AND WAVEFORM RETRIEVAL

Effortless Data Archiving

AUTOMATIC EVENT AND WAVEFORM RETRIEVAL

Instant Alarm Notification

Viewpoint MonitoringEasy to use Monitoring and Data Recording for Small Systems

Page 12: Revision 2 October 26 th , 2005

GE Multilin12

Viewpoint Monitoring: Plug-and-PlayHow to Save Time and Costs with Viewpoint Monitoring

OVERVIEW ALARMS LEARNED

METERING TRIP MAINTENANCE

Operating condition of your motor

Status of your GE Multilin Relay

Active Alarms detected by the relay

Latched Alarms that require clearing

Learned motor and RTD data

Learned motor load

All metering quantities (Amps, Volts, Power, Demand)

Motor temperature monitored by the RTD’s

Cause of the last motor trip

Pre-trip data

Trip counters and motor Starts

Total motor running hours

Page 13: Revision 2 October 26 th , 2005

GE Multilin13

Motor Monitoring

Feeder Monitoring

Transformer Monitoring

Power Quality Monitoring

Backup Power Monitoring

Breaker Monitoring

Plug and Play Monitoring ApplicationsViewpoint Monitoring

Generator Monitoring

Page 14: Revision 2 October 26 th , 2005

GE Multilin14

• Identify the status of all the devices in your power system on a customized single-line monitoring screen

• Monitor the magnitude of any power quantity measured by your metering and protection devices

• Navigate though multiple monitoring screens to view the status of different parts of your network

• Communicate with up to 25 devices and 3000 points

Create single-line monitoring screens in minutes

• Construct system diagrams with drag and drop ease

• Contains all necessary symbols and tools required for replicating your power system

• Includes a library of meters and Dials to graphically represent any metered quantity

Single-Line Monitoring and ControlViewpoint Monitoring

Monitor and Control all devices in your Power System

Page 15: Revision 2 October 26 th , 2005

GE Multilin15

Viewpoint Monitoring

Event Logging

• Automatic download of events which are stored in a system wide Sequence of Event Record• Devices continually polled to check for new Events• Sort and Query system event record to view events categorized by date, device type, timestamp, or customized criteria• No configuration required

Automatic Event and Waveform Retrieval

Waveform Archiving

• Waveform files from GE Multilin Devices automatically downloaded from a device and stored on your hard drive• Devices continually polled to check for new Waveforms• Diagnose waveform fault data recorded in your power system device in a Time-based, Phasor Quantity and Tabular view

Page 16: Revision 2 October 26 th , 2005

GE Multilin16

Trending Reports

Historical Record of monitored data• Trend up to 500 data points• Records data with 1 minute resolution indefinitely• View data in time based graphical or tabular format

Annunciator Alarming

Instant Alarm Notification• Create alarms on any monitored analog or digital data point• Receive alarm warnings through Audio, Visual or Email notification

Viewpoint Monitoring

Supported Devices

Page 17: Revision 2 October 26 th , 2005

GE Multilin17

Third Party Device SupportViewpoint Monitoring

• Add any third party device that supports RTU or Modbus TCP/IP protocol

• Add non-GE Multilin devices in your facility to your Viewpoint Monitoring and Control System

• Third Party devices can be used in your:

• Single Line Diagrams• Annunciator Panel• Trending Reports

Page 18: Revision 2 October 26 th , 2005

GE Multilin18

IEC 61850 OptionViewpoint Monitoring

Leverage all* of the power and functionality of Viewpoint Monitoring and expand it to communicate with any IEC 61850 compliant device• Simplify the process of integrating multiple vendor’s devices into a monitoring system

• Viewpoint Monitoring automatically retrieves memory maps

• Start monitoring your devices immediately

• Standardization of naming of all power systemquantities across all vendors

• Reduce troubleshooting of devices time by getting a top-down view of all IEC 61850 devices in your substation*Automatic Waveform and Event retrieval for third party devices shipping in 2006

Page 19: Revision 2 October 26 th , 2005

GE Multilin19

Ordering Information

Viewpoint Monitoring

*

* Shipping Q4, 2005

Page 20: Revision 2 October 26 th , 2005

GE Multilin20

Viewpoint Engineer

Graphical Control Logic Tool that offers Real-time Feedback of Logic Status

Page 21: Revision 2 October 26 th , 2005

GE Multilin21

• Simplify the process of creating complex control logic for Substation Automation such as advanced Tripping, Reclosing and Transfer Schemes.

• Design Logic with drag and drop ease using a library of inputs, outputs, logic gates, symbols and configuration tools

• Document actual setting file with text to make it easier for other to understand

• Create settings offline without having to communicate with the relay

Powerful Intuitive Logic Compiler

Analyses logic for potential problems in logic such as:• detecting infinite loops in logic• using inputs and outputs, or protection, control and

monitoring elements that have not been configured properly• using Virtual Outputs that have not been assigned• using inputs for hardware or features that is not available on your relay

Optimizes control logic equations to obtain maximum efficiency and to use the fewest possible lines of logic

Design Control Logic in this intuitive, easy to use IEC 1131 Graphical Logic Designer

Viewpoint EngineerGraphical Flexlogic Designer

Page 22: Revision 2 October 26 th , 2005

GE Multilin22

Analyze the Status of each component of your UR Flexlogic in Real-Time

• Identify which inputs are triggering and enabling each logic gate

• Ascertain why your control logic is not operating as you expected

• Quickly detect any wiring problems

• Determine which control interlocks are causing your breaker from operating

Viewpoint EngineerReal-Time Flexlogic Analyzer

Page 23: Revision 2 October 26 th , 2005

GE Multilin23

Device Logic Designer

System/Substation Designer

IEC 61850 System/Substation

Designer

• Create Logic in an Graphical IEC 1131 Editor

• Analyze status of logic in Real-Time

• Link Control Logic from multiple UR Devices

• Create Setting Files for multiple UR’s

• Analyze the status of Peer-to-Peer messages in Real-Time

• Shipping Q1, 2006

• Link Control Logic from multiple UR Devices

• Create Setting Files for multiple UR’s in IEC 61850 format

• Analyze the status of Peer-to-Peer messages in Real-Time

• Shipping Q4, 2006

Viewpoint Engineer

Page 24: Revision 2 October 26 th , 2005

GE Multilin24

Ordering Information

Viewpoint Engineer

Page 25: Revision 2 October 26 th , 2005

GE Multilin25

Viewpoint MaintenanceTroubleshooting and Reporting Tools

Helping Electrical Staff gather Fault Diagnostics, Security Audits and Device Status

Page 26: Revision 2 October 26 th , 2005

GE Multilin26

Viewpoint Maintenance Software Tool that creates reports to simplify all Maintenance Tasks

Viewpoint Maintenance will provide the following reports to simplify all maintenance tasks

• Fault Diagnostics Repot• Device and Equipment Status Report• Settings Security Report

Fault Diagnostics Device Status and Health

Settings Security

Page 27: Revision 2 October 26 th , 2005

GE Multilin27

Viewpoint Maintenance Single Click Fault Diagnostics

At the click of a button Viewpoint Maintenance will gather all required information including pertinent Settings Files, Oscillography, Events, Fault, Data Logger and Health Reports...

...Viewpoint Maintenance then automatically packages and compresses these files into a single .zip file...

...and stores the zipped file on your hard drive for easy emailing to your engineers or instantly emails to GE Tech support

Page 28: Revision 2 October 26 th , 2005

GE Multilin28

Viewpoint Maintenance Equipment Status Reports

Page 29: Revision 2 October 26 th , 2005

GE Multilin29

Viewpoint Maintenance Setting Security Report

Page 30: Revision 2 October 26 th , 2005

GE Multilin30

Viewpoint Maintenance Ordering Information

Page 31: Revision 2 October 26 th , 2005

GE Multilin31

EnerVista Integrator

Easily Integrate GE Multilin Devices into an existing Systems

Page 32: Revision 2 October 26 th , 2005

GE Multilin32

EnerVista IntegratorPowerful OPC / DDE Communications Server

HMI

Communications Server

EMS / DCS / SCADA

Eliminates the need for Integrators to create

memory maps for every GE Multilin device

integrated into a system

Used on systems with over 300

devices

Page 33: Revision 2 October 26 th , 2005

GE Multilin33

EnerVista IntegratorPowerful OPC / DDE Communications Server

EnerVista Integrator

SR750 SR469D60F35 PQMII

Contains the Memory Map for 40 GE Multilin devices and over 200 firmware versions

Page 34: Revision 2 October 26 th , 2005

GE Multilin34

Makes it easy to integrate Multilin Devices into existing Systems

EnerVista IntegratorPowerful OPC / DDE Communications Server

Page 35: Revision 2 October 26 th , 2005

GE Multilin35

Event Logging

• Automatic download of events which are stored in a system wide Sequence of Event Record• Devices continually polled to check for new Events• Sort and Query system event record to view events categorized by date, device type, timestamp, or customized criteria• No configuration required

Automatic Event and Waveform Retrieval

Waveform Archiving

• Waveform files from GE Multilin Devices automatically downloaded from a device and stored on your hard drive• Devices continually polled to check for new Waveforms• Diagnose waveform fault data recorded in your power system device in a Time-based, Phasor Quantity and Tabular view

EnerVista Integrator

Page 36: Revision 2 October 26 th , 2005

GE Multilin36

EnerVista IntegratorOrdering Information

Page 37: Revision 2 October 26 th , 2005

GE Multilin37

Monitor Energy Consumption from different parts of a facility and allocate costs to various departments based on the energy they used

EnerVista Energy Aggregator

Page 38: Revision 2 October 26 th , 2005

GE Multilin38

EnerVista Software

Page 39: Revision 2 October 26 th , 2005

GE Multilin39

Appendix

Page 40: Revision 2 October 26 th , 2005

GE Multilin40

Instantly view critical data including: • Number of Motor Starts

• Learned Motor Starting Current

• Motor Running Hours

• History of Motor Trips

• Real time power quantities

• Motor Temperature

PLUG-AND-PLAY MOTOR MONITORINGViewpoint Monitoring

Back to Presentation

Page 41: Revision 2 October 26 th , 2005

GE Multilin41

Instantly view critical data including: • Breaker Status

• Accumulated Breaker Arcing Current

• Real time power quantities (Amps, Volts, Demand, Energy)

• Synchronism data

PLUG-AND-PLAY FEEDER MONITORINGViewpoint Monitoring

Back to Presentation

Page 42: Revision 2 October 26 th , 2005

GE Multilin42

Instantly view critical data including: • Transformer Energization Status

• Real time power quantities (Amps, Transformer Loading, Demand)

• Current Harmonic Analysis

• Accumulated Loss of Life

• Tap Changer Position

• Hottest Winding Temperature

PLUG-AND-PLAY TRANSFORMER MONITORINGViewpoint Monitoring

Back to Presentation

Page 43: Revision 2 October 26 th , 2005

GE Multilin43

Instantly view critical data including: • Generator Loading

• Real time power quantities (Amps, Volts)

• Cause of Trip Data

• Generator Running Hours

• History of Generator Trips

• Generator Temperature

PLUG-AND-PLAY GENERATOR MONITORINGViewpoint Monitoring

Back to Presentation

Page 44: Revision 2 October 26 th , 2005

GE Multilin44

Instantly view critical data including: • Power Quality and Equipment Status

• Load unbalances using real time and maximum & minimum values

• Cost of Energy using inputs from revenue meters

• Amount of total harmonic distortion on the power system

PLUG-AND-PLAY POWER QUALITY MONITORINGViewpoint Monitoring

Back to Presentation

Page 45: Revision 2 October 26 th , 2005

GE Multilin45

Instantly view critical data including: • Availability of Normal and Emergency power sources

• Status of Power Source connections

• Real time voltages and frequency

• Switch status, Timer settings, and control Switch Position

• Stored Events and Exerciser Schedules

PLUG-AND-PLAY BACKUP MONITORINGViewpoint Monitoring

Back to Presentation

Page 46: Revision 2 October 26 th , 2005

GE Multilin46

Instantly view critical data including: • Breaker Status

• Number of breaker trip operations

• Real time Current, Voltage and Power levels

PLUG-AND-PLAY BREAKER MONITORINGViewpoint Monitoring

Back to Presentation

Page 47: Revision 2 October 26 th , 2005

GE Multilin47

Appendix A – Supported DevicesThe following Devices and Firmware Versions are supported by Viewpoint Monitoring Version 5.00

Transformer Protection Firmware Version SupportedSR745 2.4x, 2.5x, 2.6x, 2.8x

T352.4x, 2.6x 2.8x, 2.9x, 3.0x, 3.1x, 3.2x,

3.3x, 3.4x, 4.0x, 4.2x

T601.8x, 2.0x, 2.2x, 2.4x, 2.6x 2.8x, 2.9x, 3.0x, 3.1x, 3.2x, 3.3x, 3.4x, 4.0x, 4.2x

Transmission Line Protection Firmware Version SupportedD30 3.0x, 3.1x, 3.2x, 3.3x, 3.4x, 4.0x, 4.2x

D601.8x, 2.0x, 2.2x, 2.4x, 2.6x 2.8x, 2.9x, 3.0x, 3.1x, 3.2x, 3.3x, 3.4x, 4.0x, 4.2x

L901.8x, 2.0x, 2.2x, 2.4x, 2.6x 2.8x, 2.9x, 3.0x, 3.1x, 3.2x, 3.3x, 3.4x, 4.0x, 4.2x

L601.8x, 2.0x, 2.2x, 2.4x, 2.6x 2.8x, 2.9x, 3.0x, 3.1x, 3.2x, 3.3x, 3.4x, 4.0x, 4.2x

Controllers Firmware Version SupportedMicro Versa Trip Units 5.16

Enhanced Micro Versa Trip Units 4.13

C301.8x, 2.0x, 2.2x, 2.4x, 2.6x 2.8x, 2.9x, 3.0x, 3.1x, 3.2x, 3.3x, 3.4x, 4.0x, 4.2x

C601.8x, 2.0x, 2.2x, 2.4x, 2.6x 2.8x, 2.9x, 3.0x, 3.1x, 3.2x, 3.3x, 3.4x, 4.0x, 4.2x

Meters Firmware Version SupportedEPM 5000P 3.9

EPM 5200/ EPM 5300/ EPM 5350 2.4EPM 9450/ EPM 9650 217

PQM 3.3x, 3.4x, 3.5x, 3.6xPQMII 1.0x, 2.0x, 2.2x

Motor Protection Firmware Version Supported239 2.3x, 2.4x, 2.5x, 2.6x269 6.0x369 1.6x, 1.7x, 1.8x, 1.9x, 2.0x

SR469 2.5x, 2.6x, 2.8x, 2.9x, 4.0x

M602.6x 2.8x, 2.9x, 3.0x, 3.1x, 3.2x, 3.3x,

3.4x, 4.0x, 4.2x

MM2 4.0x, 4.1x, 5.0x, 5.1xMM3 1.0x. 1.1x, 1.2xRRTD 1.4x, 1.5xSPM 2.0x, 2.1x

Feeder Protection Firmware Version SupportedSR735/737 1.5xSR750/760 3.6x, 3.7x, 4.0x, 5.0x, 6.0x

F650 1.3x, 1.4x

F351.8x, 2.0x, 2.2x, 2.4x, 2.6x 2.8x, 2.9x, 3.0x, 3.1x, 3.2x, 3.3x, 3.4x, 4.0x, 4.2x

F601.8x, 2.0x, 2.2x, 2.4x, 2.6x 2.8x, 2.9x, 3.0x, 3.1x, 3.2x, 3.3x, 3.4x, 4.0x, 4.2x

Bus Firmware Version Supported

B302.2x, 2.4x, 2.6x 2.8x, 2.9x, 3.0x, 3.1x,

3.2x, 3.3x, 3.4x, 4.0x, 4.2x

Generator Firmware Version SupportedSR489 1.3x, 1.4x, 1.5x

G602.2x, 2.4x, 2.6x 2.8x, 2.9x, 3.0x, 3.1x,

3.2x, 3.3x, 3.4x, 4.0x, 4.2x

Transfer Switches Firmware Version SupportedMX150 5.4x, 6.0x

MX250 5.4x, 6.0x

Viewpoint Monitoring

Back to Presentation

Page 48: Revision 2 October 26 th , 2005

GE Multilin48

Viewpoint Maintenance Software Tool that creates reports to simplify all Maintenance Tasks

Devices Supported Firmware Versions  B30 2.6x, 2.8x, 2.9x, 3.0x, 3.1x, 3.2x, 3.3x, 3.4x, 4.0x, 4.2x, 4.4x, 4.6x C30 2.6x, 2.8x, 2.9x, 3.0x, 3.1x, 3.2x, 3.3x, 3.4x, 4.0x, 4.2x, 4.4x, 4.6x C60 2.6x, 2.8x, 2.9x, 3.0x, 3.1x, 3.2x, 3.3x, 3.4x, 4.0x, 4.2x, 4.4x, 4.6x D30 3.0x, 3.1x, 3.2x, 3.3x, 3.4x, 4.0x, 4.2x, 4.4x, 4.6x D60 2.6x, 2.8x, 2.9x, 3.0x, 3.1x, 3.2x, 3.3x, 3.4x, 4.0x, 4.2x, 4.4x, 4.6x F35 2.6x, 2.8x, 2.9x, 3.0x, 3.1x, 3.2x, 3.3x, 3.4x, 4.0x, 4.2x, 4.4x, 4.6x F60 2.6x, 2.8x, 2.9x, 3.0x, 3.1x, 3.2x, 3.3x, 3.4x, 4.0x, 4.2x, 4.4x, 4.6x G30 4.4x, 4.6x G60 2.6x, 2.8x, 2.9x, 3.0x, 3.1x, 3.2x, 3.3x, 3.4x, 4.0x, 4.2x, 4.4x, 4.6x L60 4.6x M60 2.6x, 2.8x, 2.9x, 3.0x, 3.1x, 3.2x, 3.3x, 3.4x, 4.0x, 4.2x, 4.4x, 4.6x T35 2.6x, 2.8x, 2.9x, 3.0x, 3.1x, 3.2x, 3.3x, 3.4x, 4.0x, 4.2x, 4.4x, 4.6x T60 2.6x, 2.8x, 2.9x, 3.0x, 3.1x, 3.2x, 3.3x, 3.4x, 4.0x, 4.2x, 4.4x, 4.6x SR469 2.5x, 2.6x, 2.8x, 2.9x, 4.0x SR489 1.3x, 1.4x, 1.5x SR745 2.4x, 2.5x, 2.6x, 2.8x SR750/760 3.6x, 3.7x, 4.0x, 5.0x, 6.0x

Back to Presentation