115 kV TRANSMISSION CONDUCTORS ~5' APPROX. 36'-6" 7'-0" 7'-0" 10'-0" 6" 9'-0" (TYP.) 15'-0" DIST. "X" DIST. "Y" DIST. "Z" 15'-0" MINIMUM DISTANCE TO POLE CENTERLINE TP-115 FRAMING CONDUCTOR BLOWOUT POSITION AT MIDSPAN 100'-0" TO ROAD CENTERLINE (TYPICAL) RIGHT-OF-WAY LINE REV DATE DESCRIPTION P:\04\191\15\DWG\FIGURE 3A.DWG Plot Date: 9/4/2019 10:41:02 AM Designer: Project Manager: Phone: (712) 472-2531 Project Number: S H E E T FIGURE 3A 115 kV TRANSMISSION LINE SOUTH SUBSTATION DETROIT LAKES PUBLIC UTILITIES DETROIT LAKES, MN DJH JDL 419115 ROW DETAIL TYPICAL 115 kV STRUCTURE TP-115 1. Conductor blowout analysis is conducted in accordance with the criteria of the National Electric Safety Code (NESC). 2. Conductor blowout measurements are calculated at mid-span where worst-case conductor displacement occurs. 3. Where total road ROW is less than 200' and poles are less than 15' from ROW line, TP-115B structures shall be installed. See Figure 3B for details. 4. Proposed conductor size is 336 kcmil ACSR, Linnet. NOTES: NESC CONDUCTOR BLOWOUT SUMMARY POLE FRAMING = TP-115 WIND SPEED (MPH) = 48.5 APPROXIMATE MAXIMUM POLE SPAN = 307.0 FT "X" - BLOWOUT DISTANCE (FROM POLE CENTERLINE) = 9.07 FT "Y" - BLOWOUT DISTANCE (FROM CONDUCTOR ATTACHMENT) = 4.07 FT "Z" - CLEARANCE FROM ROW TO DISPLACED CONDUCTOR = 5.93 FT

REV DATE DESCRIPTION - MN

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

115 kVTRANSMISSIONCONDUCTORS

~5'

APP

RO

X. 3

6'-6

"7'

-0"

7'-0

"10

'-0"

6"

9'-0

" (T

YP.

)

15'-0"

DIST."X"

DIST."Y"

DIST."Z"

15'-0"MINIMUM DISTANCE

TO POLE CENTERLINETP-115

FRAMING

CONDUCTORBLOWOUTPOSITION ATMIDSPAN

100'-0" TO ROAD CENTERLINE(TYPICAL)

RIGHT-OF-WAYLINE

REV DATE DESCRIPTION

P:\0

4\19

1\15

\DW

G\F

IGU

RE

3A.D

WG

Plot

Dat

e:9/

4/20

19 1

0:41

:02

AM

Designer:Project Manager:

Phone: (712) 472-2531Project Number:

SHEET

FIGURE3A

115 kV TRANSMISSION LINESOUTH SUBSTATION

DETROIT LAKES PUBLICUTILITIES

DETROIT LAKES, MN

DJHJDL419115

ROW DETAILTYPICAL

115 kV STRUCTURETP-115

1. Conductor blowout analysis is conducted in accordance with thecriteria of the National Electric Safety Code (NESC).

2. Conductor blowout measurements are calculated at mid-span whereworst-case conductor displacement occurs.

3. Where total road ROW is less than 200' and poles are less than 15'from ROW line, TP-115B structures shall be installed.See Figure 3B for details.

4. Proposed conductor size is 336 kcmil ACSR, Linnet.

NOTES:

NESC CONDUCTOR BLOWOUT SUMMARY

POLE FRAMING = TP-115

WIND SPEED (MPH) = 48.5

APPROXIMATE MAXIMUMPOLE SPAN = 307.0 FT

"X" - BLOWOUT DISTANCE(FROM POLE CENTERLINE) = 9.07 FT

"Y" - BLOWOUT DISTANCE(FROM CONDUCTOR ATTACHMENT) = 4.07 FT

"Z" - CLEARANCE FROM ROW TODISPLACED CONDUCTOR = 5.93 FT

115 kVTRANSMISSIONCONDUCTORS

~5'

APP

RO

X. 3

4'-6

"8'

-0"

8'-0

"10

'-0"

6"

9'-0

" (T

YP.

)

10'-0"

DIST."X"

DIST."Y"

DIST."Z"

5'-0"MINIMUMDISTANCETO POLE

CENTERLINETP-115B

FRAMING

175'-0" TO ROAD CENTERLINE(TYPICAL)

RIGHT-OF-WAYLINE

CONDUCTORBLOWOUTPOSITION ATMIDSPAN

REV DATE DESCRIPTION

P:\0

4\19

1\15

\DW

G\F

IGU

RE

3B.D

WG

Plot

Dat

e:11

/6/2

019

8:58

:38

AM

Designer:Project Manager:

Phone: (712) 472-2531Project Number:

SHEET

FIGURE3B

115 kV TRANSMISSION LINESOUTH SUBSTATION

DETROIT LAKES PUBLICUTILITIES

DETROIT LAKES, MN

DJHJDL419115

ROW DETAILTYPICAL

115 kV STRUCTURETP-115B

1. Conductor blowout analysis is conducted in accordance with thecriteria of the National Electric Safety Code (NESC).

2. Conductor blowout measurements are calculated at mid-span whereworst-case conductor displacement occurs.

3. Where total road ROW is 200' or greater and poles are 15' or morefrom the ROW line, TP-115 structures shall be installed.See Figure 3A for details.

4. Proposed conductor size is 336 kcmil ACSR, Linnet.

NOTES:

NESC CONDUCTOR BLOWOUT SUMMARY

POLE FRAMING = TP-115B

WIND SPEED (MPH) = 48.5

APPROXIMATE MAXIMUMPOLE SPAN = 307.0 FT

"X" - BLOWOUT DISTANCE(FROM POLE CENTERLINE) = 0.93 FT

"Y" - BLOWOUT DISTANCE(FROM CONDUCTOR ATTACHMENT) = 4.07 FT

"Z" - CLEARANCE FROM ROW TODISPLACED CONDUCTOR = 10.93 FT

6"

10'-0

"8'

-0"

8'-0

"A

PPR

OX

. 34'

-6"

10'-0"

DIST."X"

DIST."Z"

100'-0" TO ROAD CENTERLINE(TYPICAL)

115 kVTRANSMISSIONCONDUCTORSCONDUCTOR

BLOWOUTPOSITION ATMIDSPAN

±59"

10'-0"MINIMUMDISTANCETO POLE

CENTERLINETP-115B

FRAMING

RIGHT-OF-WAYLINE

Ø=TBD

CONCRETEFOUNDATION

12" (TYP)

REV DATE DESCRIPTION

P:\0

4\19

1\15

\DW

G\F

IGU

RE

3C.D

WG

Plot

Dat

e:9/

20/2

019

2:59

:40

PM

Designer:Project Manager:

Phone: (712) 472-2531Project Number:

SHEET

FIGURE3C

115 kV TRANSMISSION LINESOUTH SUBSTATION

DETROIT LAKES PUBLICUTILITIES

DETROIT LAKES, MN

DJHJDL419115

ROW DETAILTYPICAL

115 kV STRUCTURETS-5G

1. Conductor blowout analysis is conducted in accordance with thecriteria of the National Electric Safety Code (NESC).

2. Conductor blowout measurements are calculated at mid-span whereworst-case conductor displacement occurs.

3. Proposed conductor size is 336 kcmil ACSR, Linnet.

NOTES:

NESC CONDUCTOR BLOWOUT SUMMARY

POLE FRAMING = TS-5G

WIND SPEED (MPH) = 48.5

APPROXIMATE MAXIMUMPOLE SPAN = 309.0 FT

"X" - BLOWOUT DISTANCE(FROM POLE CENTERLINE) = 6.12 FT

"Z" - CLEARANCE FROM ROW TODISPLACED CONDUCTOR = 3.88 FT

REV DATE DESCRIPTION

DETROIT LAKES PUBLIC UTILITIESDETROIT LAKES, MINNESOTA FUTURE SOUTH SUBSTATION LAYOUT

P:\0

4\19

1\15

\DW

G\F

IGU

RE

4.D

WG

Plot

Dat

e:6/

24/2

019

11:0

0:32

AM

Designer:

Project Manager:BRMPAD

Phone: (712) 472-2531Project Number: 419115

0 3-16-18 PRELIMINARY APPENDIX AFIGURE 4

LEGENDPROPERTY LINE

FENCE LINE

204'

140'

-5"

28' X 40'CONTROL

ENCLOSURE

CO

UN

TY H

IGH

WA

Y 1

7

US

HW

Y 5

9

20'-0"

30'-0

"M

IN.

X0

X1

X2

X3

H3

H2

H1

10'-0

"

161'-2"12

5'-0

"14

0'-0

"15

'-0"

140'-6"

10'-0"

142'-3"

PROPERTYLINE

40

SCALE (FT.)

0 10 20NORTH

17 16 15

20 21 22

29 28 27

32 33 34¬«34

£¤59

Lois

Ln

Stall Ln

Bayview Ln

Fairh

aven

Ln Nodaway Dr

Riverside Rd

Mead

ow Vi

ew Ln

Meadow Lake RdDako

tah Be

ach Rd

110th St

Ravenswood Beach Rd

N Melissa Dr

S Melissa Dr

130th St

260th

Ave

ST22

ST17

I0 1,000 2,000

FeetAnticipated 115kV Transmission Line Alignment

Proposed 115kV Substation Site

! ! Existing 115kV Transmission Line

Sections

Agricultural Vegetation

Aquatic Vegetation

Developed and Other Human Use

Forest and Woodland

Introduced and Semi Natural Vegetation

Nonvascular and Sparse Vascular Rock Vegetation

Open Water

Polar and High Montane Vegetation

Recently Disturbed or Modified

Semi-Desert

Shrubland and Grassland

Appendix A Figure 7Existing Land Use

Proposed 115 kV Transmission LineDetroit Lakes Public Utilites

Becker County, MN

Image Source: 2017 Farm Service Agency

R 41WT 1

38N

Project Location

28

P:\04

\191\1

5\GIS\

Land

Use

Map

.mxd

Gap Analysis Land Cover

Lake Melissa

LindLake

Meadow Lake

CottageLake

21

40

38

42

4648

44

6263

37

32

39

41

50

5455

565759 58

60

1819

24

272930 3332

35

6

36

64

52

61

5349

1

10

21

11

9

67

45

34

51

65

66

20

45

8

43

14

16

7

2826

47

1315

12

31

2223

17

25

I0 1,000 2,000

FeetAnticipated 115kV Transmission Line AlignmentProposed 115kV Substation Site

! ! Existing 115kV Transmission LineSections

ZoningNOT ZONEDAGRICULTURALRESIDENTIAL

Appendix A Figure 8County Zoning

Proposed 115 kV Transmission LineDetroit Lakes Public Utilites

Becker County, MN

Image Source: 2017 Farm Service Agency

R 41WT 1

38N

Project Location

28

P:\04

\191\1

5\GIS\

Coun

ty Zo

ning.m

xd

Lake Melissa

Meadow Lake

CottageLake

LindLake

APPENDIX A TABLE 1

ENDANGERED AND THREATENED SPECIES BECKER COUNTY

DLPU 115 kV HVLT

Common name Scientific name Group Federal status State status

A Caddisfly Oxyethira ecornuta insect none threatened

Beaked Spikerush Eleocharis rostellata vascular plant none threatened

Bog Adder's Mouth Malaxis paludosa vascular plant none endangered

Common Tern Sterna hirundo bird none threatened

Goblin Fern Botrychium mormo vascular plant none threatened

Hair-like Beak RushRhynchospora

capillaceavascular plant none threatened

Hidden-fruit

Bladderwort

Utricularia

geminiscapavascular plant none threatened

Horned Grebe Podiceps auritus bird none endangered

Louisiana

Broomrape

Orobanche ludoviciana var.

ludovicianavascular plant none threatened

Northern Long-eared

BatMyotis septentrionalis mammal threatened

special

concern

Oakes' PondweedPotamogeton

oakesianusvascular plant none endangered

Olivaceous

Spikerush

Eleocharis flavescens var.

olivaceavascular plant none threatened

Poweshiek

SkipperlingOarisma poweshiek insect endangered endangered

Pugnose Shiner Notropis anogenus fish none threatened

Ram's Head Orchid Cypripedium arietinum vascular plant none threatened

Rock Sandwort Minuartia dawsonensis vascular plant none threatened

Sheathed Pondweed Stuckenia vaginata vascular plant none endangered

Sterile Sedge Carex sterilis vascular plant none threatened

Stream Parsnip Berula erecta vascular plant none threatened

Whorled Nutrush Scleria verticillata vascular plant none threatened

Wilson's Phalarope Phalaropus tricolor bird none threatened