2
EXTINGUISHING SYSTEM PARTS CLASSIFIED BY UNDERWRITERS LABORATORIES INC. ® FOR USE WITH EXTINGUISHING SYSTEM UNITS SPECIFIED IN THE INSTALLATION INSTRUCTIONS CONTROL #54S6 BULLETIN #0412 EXTINGUISHING SYSTEM PARTS For use in Ansul R-102, Piranha Systems with in situ gas valves. u u See Reference Guide below for specific valve numbers. This product is made up of units tested within limitations contained in this installation manual. No modifications are to be made. Other limitations stated in the specific Ansul system installation manual are to be followed. Installation, maintenance, and inspection are to be provided by trained and qualified personnel as stated in and , 1998 edition. Cam Setting Reference Guide S, A H H S-T PC 11 1 3 1 3 1” 3 3 3 3 3 1” 3 3 2 3 2 1” 3 3 2 3 2 2” 3 3 2 3 2 2” 3 3 3 3 3” 3 3 3 3 Retrofit Gas Valve Box 890 Lift Pin (617) Cam (866) Retaining Ring (612) Nicopress Sleeve (320S) Panel Nut (875) Lock Washer (874) Cover (868) Screw (864) Plug (823) EMT Connector (800) Reference Guide S, " A H H S-T PC 1" HV2165851 5075 5075H M6230LA6 GVSO75 1" HV2165852 5100 5100H M6230LA8 GVSO100 1" HV2165853 5125 5125H M6230LAO GVSO125 1" HV2165854 5150 5150H M6230LAB GVSO150 2" HV2165855 5200 5200H M6230LAE GVSO200 2" HV2165856 5250 M6230LAF HV2165856 3" HV2165857 5300 M6230LAG HV2165857

Retrofit Gas Valve Box

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Retrofit Gas Valve Box

EXTINGUISHING SYSTEM PARTSCLASSIFIED BY

UNDERWRITERS LABORATORIES INC.®FOR USE WITH EXTINGUISHING SYSTEM UNITS

SPECIFIED IN THE INSTALLATION INSTRUCTIONSCONTROL #54S6BULLETIN #0412

EXTINGUISHING SYSTEM PARTS

For use in Ansul R-102, Piranha Systems with in situ gas valves. in situ gas valves. in situSee Reference Guide below for specific valve numbers. This product is made up of units tested within limitations contained in this installation manual. No modifications are to be made. Other

limitations stated in the specific Ansul system installation manual are to be followed. Installation, maintenance, and inspection are to be provided by trained and qualified personnel as stated in and , 1998 edition.

Cam Setting Reference Guide S, “ A H H S-T PC 13⁄4” 1 1 3 1 3 1” 3 3 3 3 3 11⁄4” 3 3 2 3 2 11⁄2” 3 3 2 3 2 2” 3 3 2 3 2 21⁄2” 3 3 — 3 3 3” 3 3 — 3 3

Retrofit Gas Valve Box

890

Lift Pin(617)

Cam(866)

Retaining Ring(612)

Nicopress Sleeve(320S)

Panel Nut(875)

Lock Washer(874)

Cover(868)

Screw(864)

Plug(823)

EMT Connector(800)

Reference Guide S, " A H H S-T PC 13⁄4" HV2165851 5075 5075H M6230LA6 GVSO75 1" HV2165852 5100 5100H M6230LA8 GVSO100 11⁄4" HV2165853 5125 5125H M6230LAO GVSO125 11⁄2" HV2165854 5150 5150H M6230LAB GVSO150 2" HV2165855 5200 5200H M6230LAE GVSO200 21⁄2" HV2165856 5250 — M6230LAF HV2165856 3" HV2165857 5300 — M6230LAG HV2165857

Page 2: Retrofit Gas Valve Box

Ass

embl

e th

e EM

T c

onne

ctor

into

the

box

adjac

ent t

o th

e bl

ack

plas

tic p

lug.

1

Ass

embl

e th

e bo

x on

to th

e va

lve.

Plac

e th

e re

tain

ing

ring

first,

then

the

nut.

Tig

hten

.

2

Ass

embl

e on

e of

the “

C” c

lips o

nto

the

end

groo

ve in

the

lift p

in.

3

Usin

g th

e ch

art p

rovi

ded

on th

e re

vers

e, in

sert

the

lift p

in th

roug

h th

e co

rrect

hol

e in

the

cam

, so

that

it

pass

es th

roug

h th

e va

lve

stem

and

exi

ts th

roug

h th

e ca

m o

n th

e ot

her s

ide.

4

Ass

embl

e th

e se

cond

“C” c

lip o

nto

one

of th

e tw

o gr

oove

s in

the

lift p

in (t

his

secu

res t

he c

am a

ssem

bly)

.

5

Atta

ch th

e ca

ble

to th

e ca

m a

s sho

wn

and

secu

re w

ith th

e cr

imp

prov

ided

.

6

Rai

se th

e lif

t pin

with

you

r ind

ex

finge

r to

open

the

valv

e. A

t the

sam

e tim

e, wi

th y

our t

hum

b, ro

tate

the

cam

un

til it

is in

plac

e to

hol

d th

e va

lve

open

.

7 8

.Con

tinue

the

insta

llatio

n of

th

e ga

s val

ve to

the

Aut

oman

ac

cord

ing

to th

e in

struc

tions

in th

e A

nsul

Man

ual.

9.T

est t

he a

ctua

tion

of th

e ga

s val

ve.

10.A

ttach

the

cove

r plat

es to

the

box.

M

& S

:

Thi

s con

trol b

ox sh

ould

be

actu

ated

in

acco

rdan

ce w

ith th

e re

com

men

ded

syste

m m

anuf

actu

rer’s

man

ual.

To re

set c

am a

fter s

ervi

ce a

ctua

tion,

fo

llow

Figu

re 7

.

Hole

3

Hole

2

Hole

1

Rot

ate c

am

with

thum

b

Rai

se lif

t pin

w

ith in

dex

finge

r

2370 F

ireh

all

Ro

ad

Ca

na

nd

aig

ua

, N

Y 14424

UL3

470,

04/

12/0

1