Upload
others
View
8
Download
0
Embed Size (px)
Citation preview
Solutions for Maintenance, Repair and Operations
Retail Instruments cCatalogue
Hioki 3244-60 Digital Card Hitester Pencil type autoranging multimeter 3246-60 Digital Mulltimeter DT4211 TRMS Multimeter DT4222 Hioki DT4252 DT4282 Hioki 3280-10 Hioki 3280-20 Clamp Hi tester Hioki 3291-50 Hioki 3288 Hioki 3288-20 Clamp Meter Hioki Leak Clamp Meter 3283 Power Clamp Meter Hioki 3286-20 Hioki Infared Thermometer FT3700-20 Hioki FT3701-20 Hioki Insulation Tester IR4056-20 Hioki IR4057-20 Digital Earth Tester FT6031-20 Hioki Clamp Earth Tester FT6380 Phase monitor 3129 Hioki Phase Sequence Meter 3129-10 Hioki Japan Digital thermometer Hioki 3441 available in India
HIOKI Testing & Measuring Instruments www.industrialindia.com
For detailed catalogues and quotation please contact: Industrial Supply Syndicate 54, Ezra Street, Kolkata - 700 001, INDIA Phone: +91 33 22350923, 22356676 Fax : +91 33 30222923 Email: [email protected] Visit: www.industrialindia.com Page 1/3
Retail Products Catalogue
Pocket Type Autoranging Multimeter 3244-60 Pencil Type Autoranging Multimeter 3246-60 DC Voltage: 0.1mV to 500V AC Voltage: 0.1V to 500V Resistance: 0.1Ω to 42.00MΩ Continuity: Buzzer sound at 50Ω or less Only 9.5mm thick and 60gms in weight OL Protection to 500V at resistance Leads with 15mm gold plated tip pin
Display:4199 Counts LCD Voltage: 0.1mV to 600V AC/DC Resistance: 0.1Ω to 42.00MΩ Continuity: Buzzer sound at 50Ω or less Diode checking available. Auto Power Off Bright LED available to help in working in clear view of measuring point.
4 Digit Budget Digital Multimeter DT4211 4 Digit Budget True RMS Digital Multimeter DT4212 Display : 4 digits (4000 counts) LCD Voltage:0.1mV to 1000V AC/DC Resistance: 0.1Ω to 42.00MΩ Current:0.1µA to 10µA AC/DC Capacitance:0.01nF to 100µF Frequency: 1Hz to 5MHz Continuity & Diode Testing available.
Display : 4 digits (4000 counts) LCD Voltage:0.1mV to 1000V AC/DC Resistance: 0.1Ω to 42.00MΩ Current:0.1µA to 10A AC/DC Capacitance:0.01nF to 100µF Frequency: 1Hz to 5MHz Temp. Measurement available. Continuity & Diode Testing available.
Pocket –sized True RMS Digital Multimeter DT4222 True RMS Digital Multimeter DT4252 Display : 4 digits/6000 counts BARGRAPH Voltage:0.1mV to 600V AC/DC Resistance: 0.1Ω to 60.00MΩ Capacitance:1nF to 10mF Frequency: 5Hz to 10KHz Temp. Measurement available. Continuity & Diode Testing available. 3 years warranty. Light weight only 190gms.
Display : 4 digits (6000 counts) LCD Voltage:0.1mV to 1000V AC/DC Resistance: 0.1Ω to 60.00MΩ Current:0.1µA to 10A AC/DC Capacitance: 1µF to 10mF Frequency: 5Hz to 9999Hz Auto Hold. Max/Min/Average value display. USB Function available. Continuity & Diode Testing available.
True RMS Digital Multimeter DT4282 Hand Held Contact Type Thermometer 3441 Display : 5 digits (60000 counts) LCD Voltage:0.1mV to 1000V AC/DC Resistance: 0.1Ω to 600.00MΩ Current:0.1µA to 10A AC/DC Capacitance: 0.01nF to 100mF Frequency: 0.5Hz to 500KHz Temperature: -40˚C to 800˚C Auto Hold. Max/Min/Average value display. USB Function available. Continuity & Diode Testing available.
Display: 1999 Counts LCD Sensor: K Type T/C Measuring Range: -100˚C to 1300˚C ˚C/˚F Selectable Sensor to be procured separately Max/Min Data Recording Display Data Hold Auto Power Save
HIOKI Testing & Measuring Instruments www.industrialindia.com
For detailed catalogues and quotation please contact: Industrial Supply Syndicate 54, Ezra Street, Kolkata - 700 001, INDIA Phone: +91 33 22350923, 22356676 Fax : +91 33 30222923 Email: [email protected] Visit: www.industrialindia.com Page 2/3
1000A AC Clamp Meter with Slim Jaw 3280-10 1000A True RMS AC Clamp Meter with Slim Jaw 3280-20 Jaw Opening: 33mm AC Current: 42.00/420.0/1000A AC Voltage: 4.200/42.00/420.0/600V DC Voltage: 420.0m/4.200/42.00/420.0/600V Resistance: 420.0 to 42.00 MΩ 100g light and 16mm slim Independent-opening double-lever design Slim body allows easy clamping even for narrow conductors No metal (iron core) exposure, ensuring enhanced safety Safety: CAT III 600V
Jaw Opening: 33mm AC Current: 42.00/420.0/1000A AC Voltage: 4.200/42.00/420.0/600V DC Voltage: 420.0m/4.200/42.00/420.0/600V Resistance: 420.0 to 42.00 MΩ Crest factor: 1.5 at full scale. 100g light and 16mm slim Independent-opening double-lever design Slim body allows easy clamping even for narrow conductors Safety: CAT III 600V
Flip Type 1000A AC Digital Clampmeter 3291-50 1000 A AC/DC Clampmeter 3288 Display: 6000 Counts LCD Current: 0-1000 A AC Jaw Size: 30mm diameter Flip-open mechanism Data Hold Maximum value display.
Display: 4199 Counts LCD Current: 0-1000 A AC/DC Voltage: 0.1 mV to 600V Resistance: 0.1Ω to 42.00MΩ Continuity Testing Available Jaw Size: 35mm diameter
True RMS 200A Clamp-on Leak HiTester 3283 TRMS Power Clamp Meter Hioki 3286-20 Current: 1mA to 200A AC Frequency: 30Hz to 1000Hz Display: Max/Min/Average Value Record Data Hold. Auto power off. 2000 Counts. Jaw Size: 40mm Diameter
Jaw: Ø55 mm or 80mm x 20mm (busbar) Voltage: 150.0 V to 600 V, 3 ranges Current: 20.00 to 1000 A, 3 ranges Power: 3.000 kW to 1200 kW, 18 combination patterns Frequency: 30 to 1000 Hz Phase Angle&Phase Detection(3-phase)
Harmonics: Upto 20th Order , Level of each order, % of each order and total harmonic distortion (THD-F & THD-R) Min I/p Level: Voltage 10 Vrms, Current 1 Arms (sine wave) Record (Max/Min. value), Battery capacity display, DH, APO Cat III 600V
Infrared Thermometer FT3700-20 Infrared Thermometer FT3701-20 Range: -60˚C to 550˚C DS Ratio: 12:1 Emissivity: Adjustable 0.10 ~ 1.0 Sighting: Two-point laser marker Wavelength: 8 to 14 μm Additional Functions: MAX/ MIN/ DIF (MAX-MIN)/ AVG measurement, Alarm function, Backlight function
Range: -60˚C to 760˚C DS Ratio: 30:1 Emissivity: Adjustable 0.10 ~ 1.0 Sighting: Two-point laser marker Wavelength: 8 to 14 μm Additional Functions: MAX/ MIN/ DIF (MAX-MIN)/ AVG measurement, Alarm function, Backlight function.
HIOKI Testing & Measuring Instruments www.industrialindia.com
For detailed catalogues and quotation please contact: Industrial Supply Syndicate 54, Ezra Street, Kolkata - 700 001, INDIA Phone: +91 33 22350923, 22356676 Fax : +91 33 30222923 Email: [email protected] Visit: www.industrialindia.com Page 3/3
Insulation Tester IR4056-20 Insulation Tester IR4057-20 Range: 50/125/250/500/1000V
100MΩ to 4000MΩ Voltage: 4.2V to 600V DC
420V/600V AC Display: Backlight Low Resistance Measurement available.
Range:50/125/250/500/1000V 100MΩ to 4000MΩ
Voltage: 4.2V to 600V DC 420V/600V AC
Display: Backlight/Bar Graph 3 years Low Resistance Measurement available.
Portable Digital Earth Tester FT6031-03 Clamp Earth Tester FT6380 Dustproof and Waterproof Autoranging Range: 0-20/200/2000 Ω Earthing Rod and measuring cable included in accessories.
Resistance Range: 0.2Ω to 1600Ω Current: 1.00 mA to 60A Clamp Dia : 32mm Memory: 2000 data Filter Modes: Resistance / Current No wait time after powering on Back Light
Phase Sequence Meter 3129 Phase Sequence Meter 3129-10 No Metal Exposure. 70 ~ 600 V (3 phases AC) Phase Detection through bright LEDs and buzzer. Battery check function. Auto Power Off.
No Metal Exposure 70~1000V (3 phases AC) CATIII 1000V, CAT IV 600V (Anticipated Transient Overvoltage of 8000V) Hz range : 45Hz to 66Hz
Clamp Diameter: 10 to 40mm insulated wiring
Also contact us for:
Power Logger PW3360-20 and PW3360-21 (with Harmonics) Supports single to three-phase, 4-wire circuits Measure up to 780 V with a 1000 V display range Simultaneously measure up to three single-phase, 2-wire circuits (in the same power system) Broadly applicable for many jobs, including leakage current measurement (An optional clamp-on leakage sensor measures as low as 50 mA) and pulse input for expanded capabilities Graph display that provides an instant understanding of power utilization Store months of data on SD cards Identifies your power condition to help save energy Quick Set navigation helps prevent measurement mistakes Where no AC power is available battery power provides about eight hours of continuous operation The operating temperature range extends from –10°C (14°F) to 50°C (122°F). Even under battery operation, measurements can be performed from 0 °C (32°F) to 40°C (104°F) (0°C (32°F) to 50°C (122°F) when using LAN communication)