30
RESTORE: RESTORE: ACL ACL instrument instrument s s

RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement

Embed Size (px)

Citation preview

Page 1: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement

RESTORE: RESTORE: ACL ACL

instrumentsinstruments

Page 2: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement

Tibial tunnelTibial tunnel

Page 3: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement

Tibial tunnelTibial tunnel

Page 4: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement

Tibial GuideTibial Guide

• Designed for the Designed for the preciseprecise placement placement of the femural guide-wireof the femural guide-wire

• Two points on the tibial plateauTwo points on the tibial plateau• Stable blocking system Stable blocking system • Clear angle scaleClear angle scale

Page 5: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement

Tibial GuideTibial Guide

Page 6: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement

Tibial GuideTibial Guide

• Guide placementGuide placement

Page 7: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement

Tibial GuideTibial Guide

• Guide placement: 45°-55° angleGuide placement: 45°-55° angle

Page 8: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement

Tibial GuideTibial Guide

Feature Benefit

Two points of fixation Stability

Ratchet One hand set-up

Clear scale Easy to identify angles

Page 9: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement

Tibial tunnelTibial tunnel

Page 10: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement

Fully fluted reamerFully fluted reamer

• Designed for creating the tibial Designed for creating the tibial tunneltunnel

• The grooves on the rod for collecting The grooves on the rod for collecting bone chipsbone chips

• Every Every 10 mm notches10 mm notches• Diameters:Diameters:

– 6, 7, 8, 9, 10, 11, 12, 13 mm6, 7, 8, 9, 10, 11, 12, 13 mm

Page 11: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement

Fully fluted reamerFully fluted reamer

Page 12: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement

Fully fluted reamerFully fluted reamer

Feature Benefit

Flutes channel Collect bone for fullfill holes

Full thickness Less tibial tunnel divergence

Page 13: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement

Femoral tunnelFemoral tunnel

Page 14: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement

Femural aimersFemural aimers

• Designed for a perfect placement of Designed for a perfect placement of the femural guide-wirethe femural guide-wire

• They prevent the backwall breakageThey prevent the backwall breakage• Every Every 10 mm notches10 mm notches • 4 4 OffsetOffset::

– 5, 6, 7, 8 mm5, 6, 7, 8 mm

Page 15: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement

Femural aimersFemural aimers

Page 16: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement

Femural aimersFemural aimers

• OffsetOffset obtained by obtained by an easy formulaan easy formula

OFFSET = OFFSET =

Tunnel diameter /2 Tunnel diameter /2

++

Wished thichkness*Wished thichkness*

** Usually 1 or 2 mmUsually 1 or 2 mm

Page 17: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement

Femural aimersFemural aimers

Feature Benefit

2-3 mm Offset Avoid backwall break out

Graduate lenght Determine tunnel lenght

Handle with finger-hole Prevent instrument slippage

Page 18: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement

ACL instrumentsACL instruments

Page 19: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement

Acorn reamerAcorn reamer

• Designed for creating the femural Designed for creating the femural tunneltunnel

• Thin Thin shaftshaft for increasing for increasing manipulationmanipulation

• Every Every 5 mm notches5 mm notches• Diameters:Diameters:

– 8, 9, 10, 11, 12, 13 mm8, 9, 10, 11, 12, 13 mm

Page 20: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement

Acorn reamerAcorn reamer

Page 21: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement

Acorn reamerAcorn reamer

Page 22: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement

Acorn reamerAcorn reamer

Feature Benefit

Thin shaft Easy removal from tunnels

Clear scale Easy to read increments

Sharp tip Easy to use

Page 23: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement

Back cutting burrBack cutting burr

• You can clean and You can clean and chamfer the tibial chamfer the tibial tunnel tunnel

• Cannulated for better Cannulated for better useuse

Page 24: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement

Graft sizer: 8-12 mmGraft sizer: 8-12 mm

• To determine the To determine the diameter of the diameter of the graft (BTB or ST) graft (BTB or ST)

• Plastic device Plastic device with channels of with channels of different different diameters: 8, 9, diameters: 8, 9, 10, 11, 12 mm10, 11, 12 mm

8

910 11

12

Page 25: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement

ACL graft knifeACL graft knife

• Twin scalpel Twin scalpel bladesblades

• For ACL BTB graftFor ACL BTB graft• Available in:Available in:

– 8, 9, 10, 11, 12 8, 9, 10, 11, 12 mmmm

• Color codedColor coded

Page 26: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement

ACL graft knifeACL graft knife

Feature Benefit

Sterile, disposable instrument

Guaranted sharpness for each procedure

Parallel knife blade Precise cutting of the patellar tendon graft

Color coded sizing Easy to identify sizes

Page 27: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement

Pig Tail Pig Tail Tendon Tendon peelerpeeler

• Harvesting of semitendinosus and gracilis tendons

• Open “pig-tail” ring

Page 28: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement

Pig Tail tendon peelerPig Tail tendon peeler

Feature Benefit

Stainless steel Long-lasting

Solid handle and shaft Releable

Slotted end Easy entry and removal of tendon

Page 29: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement

TARGET TARGET Tendon Tendon harvesterharvester• Harvesting of semitendinosus and

gracilis tendons• Gun-shape

Page 30: RESTORE: ACL instruments. Tibial tunnel Tibial Guide Designed for the precise placement of the femural guide-wireDesigned for the precise placement

TARGET TARGET Tendon Tendon harvesterharvester

Feature Benefit

Stainless steel Long lasting, releable

Long calibrated shaft Desired graft lenght measurements

Cylindrical closed cutting tip

Precise, controlled graft harvest tracking without laceration