www.vortice.com RESIDENTIAL VENTILATION PUNTO RANGE

RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

Page 1: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

www.vortice.com

RESIDENTIAL VENTILATION

PUNTO RANGE

Page 2: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

VORTICE IN THE WORLD

Vortice has achieved European market leadership by dedicating their efforts to the production of products for ventilation, climate control, heating, extraction, purification and the treatment of air, for domestic, commercial and industrial applications. Since 1954 Vortice has been synonymous with quality and excellence and continues to make significant improvements by investing in continuous research to improve the efficiency and quality of its products.

Our current Vortice Headquarters have been located in Tribiano (Milan) since 1972.

VORTICE IN THE WORLD

Vortice main company’s philosopy is the concept that “air is our life”.

Our mission is always to provide effective solutions for improved air quality using

the latest technology to develop and manufacture effective products worldwide.

Founded in 1977, Vortice Limited is located at Burton on Trent in the East Midlands.

ENGLAND

Founded in 2012, Vortice Ventilation System is located about 200 Km from Shanghai.

CHINA

Founded in 2012, Vortice Latam in San Josè Costarica.

SOUTH AMERICAFRANCE

Founded in 1974, Vortice France is located at Crétail about 10 Km from Paris.

INDEX

Page 3: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

04 PUNTO RANGE Wall/window axial fans

12 PUNTO FILO RANGE Wall axial fans

16 PUNTO EVO RANGE Wall axial fans

22 PUNTO EVO GOLD RANGE Wall axial fans

26 PUNTO EVO FLEXO RANGE Wall axial fans

30 PUNTO GHOST RANGE In-line axial fans

INDEX

Residential Ventilation products comply with the followingEuropean Directives:

2006/95/EC Low Voltage Directive (LVD)2004/108/EC Electromagnetic Compatibility Directive (EMC)

According to the following state-of-the-art Standards:SafetyEN 60335-1, EN 60335-2-80, EN 60335-2-40, EN 622233Electromagnetic CompatibilityEN 55014-1; EN 55014-2; EN 61000-3-2; EN 61000-3-3

CE MARKING

LEGENDCERTIFIED GUARANTEED PERFORMANCEIMQ PERFORMANCE is an independent quality mark which certifies, according to international standards, performances(air flow and pressure) and noise levels of the product.

SAFESafety, power rating, enclosure protection rating (IP44 to EN 60529) and electrical insulation are certified by IMQ (Quality Mark Institute), the Italian national certifying agency. The IMQ mark certifies that the product is manufactured in compliance with the provisions of relevant established safety standards and directives: (EN 60335-1, EN 60335-2-80 and EN 62333) Low Voltage Directive (LVD) and Electromagnetic Compatibility Directive (EMC). IMQ also guarantees regular, constant monitoring of production quality.

ERP COMPLIANTThe ErP compliant logo indicates that the appliance is compatible and adheres to the ErP directive 2009/125/CE.

ErP

LONG LIFE 30.000 HThe Long Life 30,000 label certifies that the unit is installed with long life bearings and these are guaranteed to operate for 30,000 hours continuously, without mechanical failure.

TM

ENERGY SAVINGThe ES label indicates that the appliances is fitted with an EC Brushlessmotor and provides high energy savings, thanks to the wide range of speed regulation options and significantly reduced energy consumption levels.

STANDARDAll models are manufactured with shielded poles and have bronze bearings for a long life

AUTOMATICThe integral shutters positioned behind the front grille automatically open and close slowly when the unit is operated. The shutters are made from shockproof, anti-UV- treated plastic.

TIMERThe unit is activated via a switch. When the switch is turned off the unit continues to operate for a period of between 3-20 minutes, depending on the timer setting. Current regulations state a minimum of 15 minute over run where there is no opening window.

PIRThe unit activates when a persons presence is detected within the area (the sensor is located in an inclined position to increase sensitivity), and continues to operate during the person’s presence. When the person leaves the room, the unit will continue to run for between 3 -20 minutes, depending on the timer setting.

T-HCSThis unit features a relative humidity sensor that is factory set at60%. When relative humidity exceeds this level, the unit automatically starts up. This threshold setting can however be modified by the installer to 4 levels: 60%, 70%, 80%, and 90%. When the relative humidity drops below the setting the unit will continue to run for between 3 -20 minutes depending on the timer setting. The unit can also be overridden and operated via a switch if the relative humidity is below the threshold setting.

12 VThis indicates that the unit is SELV and is supplied via a voltage transformer.

PULLCORDThe unit is switched on by pulling the insulated pull cord.

LONG LIFE 30.000 h

Page 4: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

4

RESIDENTIAL VENTILATION

PRODUCT SPECIFICATIONS

PUNTO RANGE Wall/window axial fans

Wall/window axial fan suitable for through the wall installations.

Available in 4, 5 and 6" versions. Timed, PIR, Auto shutters, pull cord, humidity control, low voltage and long life models available.

Optional gasket available -maintains IPX4 integrity.

Option to window mount with additional kit (recommend the use of auto shutter versions only). IPX4 Rated.

Punto T-HCS.

Adjustable RH threshold at 60%, 70%, 80%, 90% by mean of a slide switch during installation.

Smart working mode: the product automatically switches on when the indoor relative humidity level exceeds the pre-set value. A timer automatically switches off the product when the relative humidity decreases under the pre-set limit.

30.000 hLong Life

Page 5: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

5

PUNTORANGE

30.000 hLong Life

30.000 hLong Life

Ø 100

11201 M 100/4” 11211 M 100/4” T 11681 M 100/4” PIR

11202 M 100/4” LL 11212 M 100/4” T LL 11682 M 100/4” PIR LL

12 V11203 M 100/4” 12V22150 GA 12V

11203 M 100/4” 12V22151 GA 12V T

Ø 100

11221 M 100/4” A 11231 M 100/4” AT 11683 M 100/4” A PIR

11222 M 100/4” A LL 11232 M 100/4” AT LL 11684 M 100/4” A PIR LL 11616 M 100/4” AT HCS LL

12 V11223 M 100/4” 12V22150 GA 12V

11223 M 100/4” 12V22151 GA 12V T

Ø 120

11301 M 120/5” 11311 M 120/5” T 11781 M 120/5” PIR

11302 M 120/5” LL 11312 M 120/5” T LL 11782 M 120/5” PIR LL

Ø 120

11321 M 120/5” A 11331 M 120/5” AT 11783 M 120/5” A PIR

11322 M 120/5” A LL 11332 M 120/5” AT LL 11784 M 120/5” A PIR LL 11692 M 120/5” AT HCS LL

Ø 150

11401 M 150/6” 11411 M 150/6” T 11881 M 150/6” PIR

11402 M 150/6” LL 11412 M 150/6” T LL 11882 M 150/6” PIR LL

Ø 150

11421 M 150/6” A 11431 M 150/6” AT 11883 M 150/6” A PIR

11422 M 150/6” A LL 11432 M 150/6” AT LL 11884 M 150/6” A PIR LL 11698 M 150/6” AT HCS LL

30.000 hLong Life

RANGE

30.000 hLong Life

30.000 hLong Life

30.000 hLong Life

Long Life not suitable for UK

Page 6: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

6

PUNTO RANGE Wall/window axial fans

RESIDENTIAL VENTILATION

TECHNICAL DATA

Models V~50Hz W A RPMMax Airflow Max Pressure

Lp dB(A)3m

Max°C

Kgm3/h l/s mmH2O Pa

M 100/4”

230 - 240

18 0.10 2300 90 25 3 29 37.5

50

0.60

M 120/5” 20 0.122100

175 48.6 4.5 44 39.5 0.80

M 150/6” 30 0.15 335 93.1 6 59 46.0 1.10

Models A B C D Ø E

M 100/4” 159 160 100

47

99

M 120/5” 179 181 110 119

M 150/6” 214 215 117 156

B ∅ E

A

D

C

Dimesions (mm)

DIMENSIONS

Page 7: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

7

PUNTORANGE

PUNTO RANGE | TECHNICAL DATA FOR REGULATION N° 1254/2014/UE

Models Unit ofmeasurement

Punto M 100/4”

Punto M 120/5”

Punto M 150/6”

Supplier’s name or trade mark - Vortice Vortice Vortice

Specific Energy Consumption class SEC in average climate zone - NA NA NA

Specific Energy Consumption class SEC average

kWh/m2 year

-6,6 -8,0 -9,7

Specific Energy Consumption class SEC cold -20 -21,3 -23

Specific Energy Consumption class SEC warm 1,0 -0,3 -2,0

Declared typology - URVU* URVU* URVU*

Type of drive - - - -

Type of heat recovery system HRS - - - -

Thermal efficiency of heat recovery at reference air flow % NA NA NA

Maximum flow rate [m3/s] m3/h 89 164 324

Electric power input of the fan drive, including any motor controlequipment, at maximum flow rate W 13,7 20,6 27,8

Sound power level LWA LWA [dB(A)] 58 60 67

Reference flow rate m3/s 0,0173 0,0319 0,0630

Reference pressure difference Pa 15 20 28

SPI*** W/(m3/h) 0,21348 0,17422 0,12434

Control factor CTRL - 1 1 1

Control typology - manula manual manual

Maximum internal leakage rates % NA NA NA

Maximum external leakage rates % NA NA NA

Mixing rate - NA NA NA

Airflow sensitivity to pressure variations at + 20 Pa and – 20 Pa - NA NA NA

Indoor/outdoor air tightness m3/h NA NA NA

Annual electricity consumption (AEC) kWh electricity/year 294 240 171

AHS average Annual heating savedkWh primaryenergy/year

1397 1397 1397

AHS cold Annual heating saved 2732 2732 2732

AHS warm Annual heating saved 632 632 632

Position and description of visual filter warning - NA NA NA

*URVU: Unidirectional Residential Ventilation Unit**SPI: Specific Power Input***VSD: Variable Speed DriveNA: data not applicable

Page 8: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

8

PUNTO RANGE Wall/window axial fans

RESIDENTIAL VENTILATION

PERFORMANCE CURVES

M 100/4”

q [m³/h]

q [l/s]

p [P

a]

p [m

mH2O

]

Pow

er [W

]P

ower

[W]

0 20 40 60 80 100

0 6 11 17 22 28

0 0

7 3

13 6

20 9

26 13

33 16

0

0,67

1,35

2,02

2,69

3,37

M 120/5”

q [m³/h]

q [l/s]

p [P

a]

p [m

mH2O

]

Pow

er [W

]P

ower

[W]

0 38 76 114 152 190

0 11 21 32 42 53

0 0

10 5

20 9

29 14

39 19

49 24

0

1

2

3

4

5

M 150/6”

q [m³/h]

q [l/s]

p [P

a]

p [m

mH2O

]

Pow

er [W

]P

ower

[W]

0 75 150 225 300 375

0 21 42 63 83 104

0 0

13 7

26 13

40 20

53 26

66 33

0

1

3

4

5

7

Page 9: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

9

PUNTORANGE

ACCESSORIES ON REQUEST

Models Description Code Products

C 1.5 Electric speed controller 1.5 A 1296611201 - 11202 - 11222- 11301 - 11302 - 11321 -11322 - 11401- 11402 - 11421 - 11422

SCNRB Electric speed controller Built-in 1297111201 - 11202 - 11221 - 11222 - 11301 - 11302 -11321 - 11322 - 11401 - 11402 - 11421 - 11422

SCB KIT Built-in controller adptor for C 1.5 22481 12966

Window kit

100/4” 2213111201 - 11202 - 11203 - 11211 - 11212 - 11681 - 11682 - 11221 - 11222 - 11223 - 11231 - 11232 - 11683 - 11684 - 11616

120/5” 2213211301 - 11302 - 11311 - 11312 - 11781 - 11782 - 11783 -11321 - 11322 - 11331 - 11332 - 11784 - 11692

150/6” 2213311401 - 11402 - 11411 -11412 - 11881 - 11882 - 11421 -11422 - 11431 - 11432 - 11883 - 11884 - 11698

Gasket

100/4” 2215411153 - 11201 - 11202 - 11203 - 11211 - 11212 - 11681 - 11682 - 11221 - 11222 - 11223 - 11231 - 11232 - 11683 - 11684 - 11616

120/5” 2215511301 - 11302 - 11311 - 11312 - 11781 - 11782 - 1178311321 - 11322 - 11331 - 11332 - 11784 - 11692

150/6” 2215611401 - 11402 - 11411 - 11412 - 11881 - 11882 - 11421 - 11422 - 11431 - 11432 - 11883 - 11884 - 11698

12V trasformer

12V 22150 11203 - 11223

12V T 22151 11203 - 11223

12V P 22152 All 12V models

12V THCS

22157 All 12V models

Page 10: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

10

PUNTO RANGE Wall/window axial fans

RESIDENTIAL VENTILATION

Kit to window-mount

Will allow any Vortice® Punto unit to be fitted to any single or double glazed window. The data and performances for the product + kit are IMQ Performance certified. The kit consists of closed-cell, expanded-polyethylene gasket and external grille, intermediate flange fitting, spacer, and a anti-UV-threaded ABS ring. Glass thickness: 2/3 mm (min) - 17/20 mm (max). Insulation class: II.

Models Kit Code W A RPM Max Airflow

Lp dB(A) 3 m

Max°C

Kgm3/h l/s

M 100/4’’ F 100/4” 22131 18 0.10 2300 85 23.6 38

50

0.85

M 120/5’’ F 120/5” 22132 20 0.12 2000 140 38.9 40.5 1.15

M 150/6’’ F 150/6” 22133 30 0.15 1950 280 77.8 44.5 1.56

Models A B C Ø Glass hole Thikness

M 100/4” 158 69 22 123 ÷ 128

20M 120/5” 179 80 33 143 ÷ 148

M 150/6” 213 87 40 178 ÷ 183

A BC

Dimesions (mm)

KIT TO WINDOW-MOUNT

Gasket

Made of soft rubber to prevent water infiltration and maintain IPX4 protection on all surfaces.

Page 11: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

11

PUNTORANGE

NOTE

Page 12: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

12

RESIDENTIAL VENTILATION

PRODUCT SPECIFICATIONS

PUNTO FILO RANGE Ultra slim axial fans

Ultra Slim Axial Fan Suitable for through the wall installations.

Available in 4,5 and 6" versions. Timed, PIR, HCS models available. Integral backdraught shutter stops draught entering the dwelling when the fan is not in operation. Optional gasket the avaible - maintains IPX4 integrity. IPX4 Rating.

30.000 hLong Life

Page 13: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

13

PUNTO FILORANGE

30.000 hLong Life

Ø 100

11123 MF 100/4” 11127 MF 100/4” T

11131 MF 100/4” LL 11135 MF 100/4” T LL 11185 MF 100/4” PIR LL 11139 MF 100/4” THCS LL

Ø 120

11124 MF 120/5” 11128 MF 120/5” T

11136 MF 120/5” T LL 11186 MF 120/5” PIR LL 11149 MF 120/4” THCS LL

Ø 150

11125 MF 150/6” 11129 MF 150/6” T

11137 MF 150/6” T LL 11187 MF 150/6” PIR LL 11176 MF 150/6” THCS LL

RANGE

30.000 hLong Life

30.000 hLong Life

TECHNICAL DATA

Models V~50Hz W A RPMMax Airflow Max Pressure

Lp dB(A)3m

Max°C

Kgm3/h l/s mmH2O Pa

MF 100/4”

230 - 240

15 0.09 2400 85 24 3 29 31.0

50

0.50

MF 120/5” 20 0.12 2150 175 49 5 49 34.4 0.7

MF 150/6” 30 0.15 2100 335 93 6 59 40.1 0.99

Some LL models not in UK

Long Life not suitable for UK

Page 14: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

14

PUNTO FILO RANGE Ultra slim axial fans

RESIDENTIAL VENTILATION

PUNTO FILO RANGE | TECHNICAL DATA FOR REGULATION N° 1254/2014/UE

Models Unit ofmeasurement

Punto Filo MF 100/4”

Punto FiloMF 120/5”

Punto FiloMF 150/6”

Supplier’s name or trade mark - Vortice Vortice Vortice

Specific Energy Consumption class SEC in average climate zone - NA NA NA

Specific Energy Consumption class SEC average

kWh/m2 year

-5,4 -8,8 -9,9

Specific Energy Consumption class SEC cold -218,7 -22,1 -23,2

Specific Energy Consumption class SEC warm 2,3 -1,1 -2,2

Declared typology - URVU* URVU* URVU*

Type of drive - - - -

Type of heat recovery system HRS - - - -

Thermal efficiency of heat recovery at reference air flow % NA NA NA

Maximum flow rate [m3/s] m3/h 78 173 332

Electric power input of the fan drive, including any motor controlequipment, at maximum flow rate W 14,1 21,4 26,7

Sound power level LWA LWA [dB(A)] 52 60 61

Reference flow rate m3/s 0,0152 0,0336 0,0646

Reference pressure difference Pa 17 24 32

SPI*** W/(m3/h) 0,24908 0,15111 0,11833

Control factor CTRL - 1 1 1

Control typology - manual manual manual

Maximum internal leakage rates % NA NA NA

Maximum external leakage rates % NA NA NA

Mixing rate - NA NA NA

Position and description of visual filter warning - NA NA NA

Airflow sensitivity to pressure variations at + 20 Pa and – 20 Pa - NA NA NA

Indoor/outdoor air tightness m3/h NA NA NA

Annual electricity consumption (AEC) kWh electricity/year 343 208 163

AHS average Annual heating savedkWh primaryenergy/year

1397 1397 1397

AHS cold Annual heating saved 2732 2732 2732

AHS warm Annual heating saved 632 632 632 *URVU: Unidirectional Residential Ventilation Unit **SPI: Specific Power Input ***VSD: Variable Speed Drive NA: data not applicable

Models A B C Ø D

MF 100/4” 159

17

77 98

MF 120/5” 179 89 119

MF 150/6” 214 96 156

Dimesions (mm)

A C

B

D

DIMENSIONS

Page 15: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

15

PUNTO FILORANGE

PERFORMANCE CURVES

M 100/4”

q [m³/h]

q [l/s]

p [P

a]

p [m

mH2O

]

Pow

er[W

]P

ower

[W]

0 19 38 57 76 95

0 5 11 16 21 26

0 0

7 3

13 6

20 10

26 13

33 16

0

0,67

1,35

2,02

2,69

3,37

M 120/5”

q [m³/h]

q [l/s]

p [P

a]

p [m

mH2O

]

Pow

er [W

]P

ower

[W]

0 39 78 117 156 195

0 11 22 33 43 54

0 0

11 5

22 10

33 15

44 20

55 25

0

1

2

3

4

6

M 150/60”

q [m³/h]

q [l/s]

p [P

a]

p [m

mH2O

]

Pow

er [W

]P

ower

[W]

0 75 150 225 300 375

0 21 42 63 83 104

0 0

13 7

26 13

39 20

53 27

66 33

0

1

3

4

5

7

ACCESSORIES ON REQUEST

Models Description Code Products

C 1.5 Electric speed controller 1.5 A 12966 11122 - 11123 - 11131 - 11124 - 11132 - 11125 - 11133

SCB KIT Built-in controller adptor for C 1.5 22481 12966

Kit SF - Gasket

100/4” 22162 11122 - 11126 - 11138 - 11123 - 11131 - 11127 - 11135 - 11185 - 11139

120/5” 22162 11124 - 11132 - 11128 - 11136 - 11186 - 11149

150/6” 22164 11125 - 11133 - 11129 - 11137 - 11187 - 11176

Page 16: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

16

RESIDENTIAL VENTILATION

PRODUCT SPECIFICATIONS

PUNTO EVO RANGE Low decibel axial fans

Low decibel axial fan suitable for through the wall installations.

4" versions available. Low power consumption. Low decibel rating (20.8 DbA). Shock-proof, UV resistant, ABS made enclosures. 2 speeds. Timed, Timer Plus, HCS and PIR versions available. Integral backdraught shutter stops draught entering the dwelling when the fan is not in operation. IP45 Rated.

30.000 hLong Life

Page 17: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

17

PUNTO EVORANGE

RANGE

Ø 100 11260ME 100/4” LL

11264ME 100/4” LL T

11261ME 100/4” LL TP

11262ME 100/4” LL TP HCS

11263ME 100/4” LL PIR

Ø 120 11270ME 120/5” LL

11274ME 120/5” LL T

11271ME 120/5” LL TP

11272ME 120/5” LL TP HCS

11273ME 120/5” LL PIR

30.000 hLong Life

. . . . . . . . . .

.

I I I I I I I I I I I I I I I I I I I I I I I I I I I I I

I I I

I I I

I I I

I I

I I I I I

l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l

The Basic version is equipped with a 2-speed PCB.

The Timer unit is activate via a switch. When the switch is turned off the unit continues to operate for a period of between 3-20 minutes depending on the timer setting. Current regulations state a minimum of 15 minute over run where there is no opening window.

The Timer Plus unit is equipped with an intelligent timer which includes variable delay start and fan overrun. The unit can also be set to automatically activate the fan for a pre-set length of time at variable intervals up to every 24 hours.

The Timer Plus HCS unit features a relative humidity sensor that is factory set at 60%. When relative humidity exceeds this level, the unit automatically starts up. This threshold setting can however be modified by the installer to 4 levels: 60%, 70%, 80%, and 90%. When the relative humidity drops below the setting the unit will continue to run for between 3 -20 minutes depending on the timer setting. The unit can also be overridden and operated via a switch if the relative humidity is below the threshold setting. The unit also has a timed delay.

The Timer PIR unit activates when a person’s presence is detected within the area (the sensor is located in an inclined position to increase sensitivity) and continues to operate during the persons presence. When the person leaves the room the unit will continue to run for between 3-20 minutes, depending on the timer setting.

. . . . . . . . . .

.

I I I I I I I I I I I I I I I I I I I I I I I I I I I I I

I I I

I I I

I I I

I I

I I I I I

l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l

Page 18: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

18

PUNTO EVO RANGE Low decibel axial fans

RESIDENTIAL VENTILATION

TECHNICAL DATA

Models A B C Ø D E F G H Ø L

ME 100/4” LL159 159

116.598 61.5

40.5132 132 3.5

ME 100/4” LL PIR 118 42

Dimesions (mm)

A

B

C

E

D

F

G

H

L

DIMENSIONS

Models V~50Hz Wmin/max

Amin/max

RPMmin/max

Max Airflow Max Pressure Lp dB(A)3m

min/max

Lw dB(A)

min/max

Max°C

Kgm3/hmin/max

l/smin/max

mmH2Omin/max

Pamin/max

ME 100/4” LL 230 - 24059

0.0390.052

17002240

6595

18.126.4

2.54.7

24.5246.09

20.826.9

41.347.4

50 0.60

Page 19: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

19

PUNTO EVORANGE

PUNTO EVO RANGE | TECHNICAL DATA FOR REGULATION N° 1254/2014/UE

Models Unit ofmeasurement

Punto EvoME 100/4”

Supplier’s name or trade mark - Vortice

Specific Energy Consumption class SEC in average climate zone - NA

Specific Energy Consumption class SEC average

kWh/m2 year

-9,9

Specific Energy Consumption class SEC cold -23,2

Specific Energy Consumption class SEC warm -2,2

Declared typology - URVU*

Type of drive - -

Type of heat recovery system HRS - -

Thermal efficiency of heat recovery at reference air flow % NA

Maximum flow rate [m3/s] m3/h 93

Electric power input of the fan drive, including any motor controlequipment, at maximum flow rate W 8,1

Sound power level LWA LWA [dB(A)] 68

Reference flow rate m3/s 0,0181

Reference pressure difference Pa 22

SPI*** W/(m3/h) 0,11828

Control factor CTRL - 1

Control typology - manual

Maximum internal leakage rates % NA

Maximum external leakage rates % NA

Mixing rate - NA

Airflow sensitivity to pressure variations at + 20 Pa and – 20 Pa - NA

Indoor/outdoor air tightness m3/h NA

Annual electricity consumption (AEC) kWh electricity/year 163

AHS average Annual heating savedkWh primaryenergy/year

1397

AHS cold Annual heating saved 2732

AHS warm Annual heating saved 632

Position and description of visual filter warning - NA

*URVU: Unidirectional Residential Ventilation Unit**SPI: Specific Power Input***VSD: Variable Speed DriveNA: data not applicable

Page 20: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

20

PUNTO EVO RANGE Low decibel axial fans

RESIDENTIAL VENTILATION

ME 100/4” LL

q [m³/h]

q [l/s]

p [P

a]

p [m

mH2O

]

Pow

er [W

]P

ower

[W]

Pow

er [W

]P

ower

[W]

0 21 42 64 85 106

0 6 12 18 24 29

0 0

10 2

21 4

31 6

42 8

52 10

0

1

2

3

4

5

PERFORMANCE CURVES

Front panel can easily be removed without tools

Flow conveyor able toreduce turbulence andoptimize performance

High efficiency helico-centrifugal impeller ensuring high performance for flow rate and pressure withlow noise emissions

Motor holder made of anti-UV ABS thermoplastic material

Butterfly backdraughtshutter built intothe motor carrier

EXPLODED VIEW

Page 21: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

21

PUNTO EVORANGE

NOTE

Page 22: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

22

RESIDENTIAL VENTILATION

PRODUCT SPECIFICATIONS

PUNTO EVO Gold RANGE Low decibel axial fans in 4 metallic finishes

Low Decibel Axial Fans in 4 metallic finishes suitable for through the wall installations.

4" versions available. Available in black, silver, rose and gold metallic finishes. Low power consumption. Low decibel rating. 2 speeds. Timed, Timer Plus, HCS and PIR versions available. Motor carriers with airfoil flow straighteners. Integral backdraught shutter stops backdraught coming into the dwelling when fan is not in operation. IP45 Rated.

30.000 hLong Life

Page 23: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

23

PUNTO EVO GOLDRANGE

RANGE

Ø 100

11306ME 100/4” LL

11307ME 100/4” LL

11308ME 100/4” LL

11309ME 100/4” LL

11316ME 100/4” LL T

11317ME 100/4” LL T

11318ME 100/4” LL T

11319ME 100/4” LL T

30.000 hLong Life

30.000 hLong Life

Gold Rose Black Silver

The Basic version is equipped with a 2-speed PCB.

The Timer unit is activate via a switch. When the switch is turned off the unit continues to operate for a period of between 3-20 minutes depending on the timer setting. Current regulations state a minimum of 15 minute over run where there is no opening window.

Page 24: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

24

PUNTO EVO Gold RANGE Low decibel axial fans in 4 metallic finishes

RESIDENTIAL VENTILATION

TECHNICAL DATA

Models V~50Hz Wmin/max

Amin/max

RPMmin/max

Max Airflow Max Pressure Lp dB(A)3m

min/max

Lw dB(A)

min/max

Max°C

Kgm3/hmin/max

l/smin/max

mmH2Omin/max

Pamin/max

ME 100/4” LL 23059

0.0390.052

17002240

6595

18.126.4

2.54.7

24.5246.09

20.826.9

41.347.4

50 0.60

Models A B C Ø D E F G H Ø L

ME 100/4” LL 159 159 116.5 98 61.5 40.5 132 132 3.5

Dimesions (mm)

DIMENSIONS

A

B

C

E

D

F

G

H

L

ME 100/4” LL

q [m³/h]

q [l/s]

p [P

a]

p [m

mH2O

]

Pow

er [W

]P

ower

[W]

Pow

er [W

]P

ower

[W]

0 21 42 64 85 106

0 6 12 18 24 29

0 0

10 2

21 4

31 6

42 8

52 10

0

1

2

3

4

5

PERFORMANCE CURVES

Page 25: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

25

PUNTO EVO GOLDRANGE

PUNTO EVO GOLD RANGE | TECHNICAL DATA FOR REGULATION N° 1254/2014/UE

Models Unit ofmeasurement

Punto Evo GoldME 100/4” LL

Supplier’s name or trade mark - Vortice

Specific Energy Consumption class SEC in average climate zone - NA

Specific Energy Consumption class SEC average

kWh/m2 year

-9,9

Specific Energy Consumption class SEC cold -23,2

Specific Energy Consumption class SEC warm -2,2

Declared typology - URVU*

Type of drive - -

Type of heat recovery system HRS - -

Thermal efficiency of heat recovery at reference air flow % NA

Maximum flow rate [m3/s] m3/h 93

Electric power input of the fan drive, including any motor controlequipment, at maximum flow rate W 8,1

Sound power level LWA LWA [dB(A)] 68

Reference flow rate m3/s 0,0181

Reference pressure difference Pa 22

SPI*** W/(m3/h) 0,11828

Control factor CTRL - 1

Control typology - manual

Maximum internal leakage rates % NA

Maximum external leakage rates % NA

Mixing rate - NA

Airflow sensitivity to pressure variations at + 20 Pa and – 20 Pa - NA

Indoor/outdoor air tightness m3/h NA

Annual electricity consumption (AEC) kWh electricity/year 163

AHS average Annual heating savedkWh primaryenergy/year

1397

AHS cold Annual heating saved 2732

AHS warm Annual heating saved 632

Position and description of visual filter warning - NA

*URVU: Unidirectional Residential Ventilation Unit**SPI: Specific Power Input***VSD: Variable Speed DriveNA: data not applicable

Page 26: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

26

PRODUCT SPECIFICATIONS

FlexoPUNTO EVO RANGE Stylish curved axial fans

Stylish curved axial fan suitable for through the wall installation.

4" and 5" versions. Low power consumption. Stylish curved grille - easier to clean. Timed and Long Life models available. Integral backdraught shutter stops backdraught coming into the dwelling when fan is not in operation. IP45 Rated

30.000 hLong Life

RESIDENTIAL VENTILATION

ZONE 1

Page 27: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

27

PUNTO EVO FLEXORANGE

TECHNICAL DATA

Models Code V~50Hz W A RPMMax Airflow Max Pressure Lp dB(A)

3mmin/max

Max°C

Kgm3/h l/s mmH2O Pa

MEX 100/4” LL 1S 11313

230

90.052

2175 90 25 4 39.23 26.9

50

0.60MEX 100/4” LL 1S T 11314

MEX 120/5” LL 1S 1133313 0.095 2075 175 48,6 5 49.04 32.3 0,77

MEX 120/5” LL 1S T 11334

A

B

C

E

D

F

G

H

L

A

B

C

E

D

F

G

H

L

A

B

C

E

D

F

G

H

L

Models A B C Ø D E F G H Ø L

MEX 100/4” LL 173 173 126 98 61.5 50 132 1323.5

MEX 120/5” LL 193 193 138 119 71 53 152 152

Dimesions (mm)

DIMENSIONS

Page 28: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

28

RESIDENTIAL VENTILATION

MEX 100/4” LL MEX 120/5” LL

q [m³/h]

q [l/s]

p [P

a]

p [m

mH2O

]

Pow

er [W

]P

ower

[W]

0 20 40 60 80 100

0 6 11 17 22 28

0 0

9 2

18 4

27 6

35 8

44 10

0

0,9

1,8

2,71

3,61

4,51

q [m³/h]

q [l/s]

p [P

a]

p [m

mH2O

]

Pow

er [W

]P

ower

[W]

0 39 78 117 156 195

0 11 22 33 43 54

0 0

11 3

22 6

33 10

44 13

55 16

0

1

2

3

4

6

PERFORMANCE CURVES

Front panel can easily be removed without tools

Flow conveyor able toreduce turbulence andoptimize performance

High efficiency helico-centrifugal impeller ensuring high performance for flow rate and pressure withlow noise emissions

Motor holder made of anti-UV ABS thermoplastic material

Butterfly backdraughtshutter built intothe motor carrier

EXPLODED VIEW

FlexoPUNTO EVO RANGE Stylish curved axial fans

Page 29: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

29

PUNTO EVO FLEXORANGE

PUNTO EVO FLEXO RANGE | TECHNICAL DATA FOR REGULATION N° 1254/2014/UE

Models Unit ofmeasurement

Punto EvoMEX 100/4” LL

Punto EvoMEX 120/5” LL

Supplier’s name or trade mark - Vortice Vortice

Specific Energy Consumption class SEC in average climate zone - NA NA

Specific Energy Consumption class SEC average

kWh/m2 year

-9,9 -10

Specific Energy Consumption class SEC cold -23,2 -23,4

Specific Energy Consumption class SEC warm -2,2 -2,4

Declared typology - URVU* URVU*

Type of drive - - -

Type of heat recovery system HRS - - -

Thermal efficiency of heat recovery at reference air flow % NA NA

Maximum flow rate [m3/s] m3/h 87 168

Electric power input of the fan drive, including any motor controlequipment, at maximum flow rate W 8,0 14,1

Sound power level LWA LWA [dB(A)] 47 53

Reference flow rate m3/s 0,0169 0,0327

Reference pressure difference Pa 21 19

SPI*** W/(m3/h) 0,11823 0,11480

Control factor CTRL - 1 1

Control typology - manual manual

Maximum internal leakage rates % NA NA

Maximum external leakage rates % NA NA

Mixing rate - NA NA

Airflow sensitivity to pressure variations at + 20 Pa and – 20 Pa - NA NA

Indoor/outdoor air tightness m3/h NA NA

Annual electricity consumption (AEC) kWh electricity/year 163 158

AHS average Annual heating savedkWh primaryenergy/year

1397 1397

AHS cold Annual heating saved 2732 2732

AHS warm Annual heating saved 632 632

Position and description of visual filter warning - NA NA

*URVU: Unidirectional Residential Ventilation Unit**SPI: Specific Power Input***VSD: Variable Speed DriveNA: data not applicable

Page 30: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

30

RESIDENTIAL VENTILATION

PRODUCT SPECIFICATIONS

PUNTO GHOST RANGE In-line axial fans

In-line axial fans suitable for through the wall installations.

4",5" and 6" versions. Timed and Long Life models available. IPX4 Rated

ZONE 1

Page 31: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

31

PUNTO GHOSTRANGE

RANGE

ModelsCode

V~50Hz W A RPMMax Airflow Max Pressure Lp dB(A)

3mmin/max

Max°C

KgBasic TImer m3/h l/s mmH2O Pa

MG 100/4” LL 11100 11101

230240

18 0.10 2415 80 22.2 2.6 25 39 0.43

MG 120/5” 11116 -20 0.12 2250 160

444.5 44 43

50

0.43MG 120/5” LL 11102 11103 44.4

MG 150/6” 11117 -30 0.18 2200 320

897.0 69 48 0.18

MG 150/6” LL 11104 11105 88.9

Dimesions (mm)

Models A B C

MG 100/4” LL99

92

89MG 100/4” LL T 96.5

MG 120/5”

119103

MG 120/5” LL

MG 120/5” LL T 107.5100

MG 150/6”

155110

MG 150/6” LL107

MG 150/6” LL T 114.5

DIMENSIONS

∅ A

B

C

LL models only in UK

Page 32: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

32

RESIDENTIAL VENTILATION

PUNTO GHOST RANGE In-line axial fans

PUNTO RANGE | TECHNICAL DATA FOR REGULATION N° 1254/2014/UE

Models Unit ofmeasurement

Punto GhostMG 100/4”

Punto GhostMG 120/5”

Punto GhostMG 150/6”

Supplier’s name or trade mark - Vortice Vortice Vortice

Specific Energy Consumption class SEC in average climate zone - NA NA NA

Specific Energy Consumption class SEC average

kWh/m2 year

-5,4 -7,6 -10

Specific Energy Consumption class SEC cold -18,8 -21,0 -23,4

Specific Energy Consumption class SEC warm 2,2 0,0 -2,4

Declared typology - URVU* URVU* URVU*

Type of drive - - - -

Type of heat recovery system HRS - - - -

Thermal efficiency of heat recovery at reference air flow % NA NA NA

Maximum flow rate [m3/s] m3/h 77 157 311

Electric power input of the fan drive, including any motor controlequipment, at maximum flow rate W 13,7 20,5 25,0

Sound power level LWA LWA [dB(A)] 60 64 69

Reference flow rate m3/s 0,0150 0,0305 0,0605

Reference pressure difference Pa 14 18 30

SPI*** W/(m3/h) 0,24861 0,18471 0,11484

Control factor CTRL - 1 1 1

Control typology - manual manual manual

Maximum internal leakage rates % NA NA NA

Maximum external leakage rates % NA NA NA

Mixing rate - NA NA NA

Airflow sensitivity to pressure variations at + 20 Pa and – 20 Pa - NA NA NA

Indoor/outdoor air tightness m3/h NA NA NA

Annual electricity consumption (AEC) kWh electricity/year 343 255 158

AHS average Annual heating savedkWh primaryenergy/year

1397 1397 1397

AHS cold Annual heating saved 2732 2732 2732

AHS warm Annual heating saved 632 632 632

Position and description of visual filter warning - NA NA NA

*URVU: Unidirectional Residential Ventilation Unit**SPI: Specific Power Input***VSD: Variable Speed DriveNA: data not applicable

Page 33: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

33

PUNTO GHOSTRANGE

PERFORMANCE CURVES

MG 100/4”

q [m³/h]

q [l/s]

p [P

a]

p [m

mH2O

]

Pow

er [W

]P

ower

[W]

0 18 36 53 71 89

0 5 10 15 20 25

0 0

6 3

12 6

17 10

23 13

29 16

0

0,59

1,18

1,77

2,36

2,95

MG 120/5”

q [m³/h]

q [l/s]

p [P

a]

p [m

mH2O

]

Pow

er [W

]P

ower

[W]

0 36 72 108 144 180

0 10 20 30 40 50

0 0

10 5

20 10

29 14

39 19

49 24

0

1

2

3

4

5

MG 150/6”

q [m³/h]

q [l/s]

p [P

a]

p [m

mH2O

]

Pow

er [W

]P

ower

[W]

0 72 144 216 288 360

0 20 40 60 80 100

0 0

13 6

26 12

39 18

52 24

66 30

0

1

3

4

5

7

Page 34: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

34

RESIDENTIAL VENTILATION

PUNTO GHOST RANGE Wall axial fans

ACCESSORIES ON REQUEST

Models Description Code Products

C 1.5 Electric speed controller 1.5 A 12966 11100 - 11116 - 11102 - 11117 - 11104

SCNRB Electric speed controller Built-in 12971 11100 - 11102

SCB KIT Built-in controller adptor for C 1.5 22481 12966

Loft mounting brackets

100/4” 22259 11100 - 11101

120/5” 22260 11116 - 11102 - 11103

150/6” 22261 11117 - 11104 - 11105

Grille kit

100/4” 22140 11100 - 11101

120/5” 22141 11116 - 11102 - 11103

150/6” 22142 11117 - 11104 - 11105

Some accessories not suitable for the UK

Page 35: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

35

PUNTO GHOSTRANGE

APPLICATION

Page 36: RESIDENTIAL VENTILATION - Vortice · AHS cold Annual heating saved 2732 2732 2732 AHS warm Annual heating saved 632 632 632 Position and description of visual filter warning - NA

Conforms to the standards: EN 60335-1, EN 60335-2-80, EN 60529, EN 62233Performance checked according to: CEI 107-53/1986 (EN13-4: 2004)

EMC: EN 55014–1, EN 55014-2, EN 61000-3-2, EN 60555-1European Directives for CE mark: Low Voltage Directive (2006/95/CE)

Directive on Electromagnetic Compatibility: (2004/108/CE)

Cod. 5.170.084.908 UK 03/17

The description and illustrations in this catalogue are understood to be indicative and are not binding. Vortice reserves the right, while not changing the essential characteristcs of the models described and illustred, to modify products whenever necessary and without warning.