RESIDENTIAL REPORT
1234 Main St.Edmonton AB t5t3e9
Buyer Name12/18/2017 9:00AM
InspectorBanti Shaw
CPI780 862 3549
AgentAgent Name555-555-5555
23569
1416181921242631
Table of Contents
Table of ContentsSUMMARY1: INSPECTION DETAILS2: ROOF3: EXTERIOR4: BASEMENT, FOUNDATION, CRAWLSPACE & STRUCTURE5: HEATING6: COOLING7: PLUMBING8: ELECTRICAL9: ATTIC, INSULATION & VENTILATION10: DOORS, WINDOWS & INTERIOR11: BUILT-IN APPLIANCES
17512 85 Ave NW Srinivas Mandapaka
InspecUs Page 2 of 31
☐ Doors, Windows & Interior - Countertops & Cabinets: Cabinet Hinge Loose
☐ Doors, Windows & Interior - Steps, Stairways & Railings: No Handrail
☐ Doors, Windows & Interior - Ceilings: Stain(s) on Ceiling
☐ Doors, Windows & Interior - Ceilings: Possible Mold
☐ Doors, Windows & Interior - Ceilings: Minor Damage
☐ Doors, Windows & Interior - Walls: Moisture Damage
☐ Doors, Windows & Interior - Floors: Damaged (General)
☐ Doors, Windows & Interior - Floors: Moderate Wear
☐ Doors, Windows & Interior - Windows: Damaged
☐ Doors, Windows & Interior - Doors: Door Knobs missing
☐ Attic, Insulation & Ventilation - Ventilation: Attic Ventilation Insufficient
☐ Attic, Insulation & Ventilation - Attic Insulation: Insufficient Insulation
SUMMARY
General Information: Overview A home inspection is a non-invasive, visual examination of the accessible areas of the property,designed to identify areas of concern within specific systems or components defined by the City OfEdmonton Standards of Practice, that are both observed and deemed material by the inspector atthe exact date and time of inspection. Any and all recommendations for repair, replacement,evaluation, and maintenance issues found, should be evaluated by the appropriate tradescontractors within the clients inspection contingency window or prior to closing, which is contractapplicable, in order to obtain proper dollar amount estimates on the cost of said repairs and alsobecause these evaluations could uncover more potential issues than able to be noted from a purelyvisual inspection of the property. This inspection will not reveal every concern or issue that exists,but only those material defects that were observable on the day of the inspection. This inspection isintended to assist an evaluation of the overall condition of the dwelling only. This inspection is not aprediction of future conditions and conditions with the property are subject to change the momentwe leave the premises.
6MAINTENANCE ITEMS
18RECOMMENDATIONS
19IMMEDIATE/SAFETY ITEMS
17512 85 Ave NW Srinivas Mandapaka
InspecUs Page 3 of 31
☐ Electrical - Carbon Monoxide Detectors: Recommend Installation
☐ Electrical - Smoke Detectors: Recommend Installation
☐ Electrical - GFCI & AFCI: No GFCI Protection Installed
☐ Electrical - Lighting Fixtures, Switches & Receptacles: Cover Plates Damaged
☐ Electrical - Branch Wiring Circuits, Breakers & Fuses: Aluminum Branch Circuits
☐ Electrical - Main & Subpanels, Service & Grounding, Main Overcurrent Device: Breaker Incorrectly Wired
☐ Basement, Foundation, Crawlspace & Structure - Wall Structure: Evidence of Water Intrusion
☐ Basement, Foundation, Crawlspace & Structure - Foundation: Foundation Cracks - Minor
☐ Exterior - Vegetation, Grading, Drainage & Retaining Walls: Negative Grading
☐ Exterior - Vegetation, Grading, Drainage & Retaining Walls: Standing Water
☐ Exterior - Eaves, Soffits & Fascia: Fascia - Rotted
☐ Exterior - Decks, Balconies, Porches & Steps: Guardrail
☐ Exterior - Decks, Balconies, Porches & Steps: Deck - Rotted Boards
☐ Exterior - Walkways, Patios & Driveways: Driveway Trip Hazard
☐ Exterior - Walkways, Patios & Driveways: Driveway Cracking - Major
☐ Exterior - Exterior Doors: Egress window
☐ Exterior - Exterior Doors: Weatherstripping Not Present
☐ Exterior - Exterior Doors: Paint/Refinish Needed
☐ Exterior - Siding, Flashing & Trim: Evidence of Water Intrusion
☐ Roof - Roof Drainage Systems: Underground Roof Drainage
☐ Roof - Roof Drainage Systems: Gutter Improperly Sloped
☐ Roof - Roof Drainage Systems: Debris
☐ Roof - Skylights, Chimneys & Other Roof Penetrations: Chimney Repoint Needed
☐ Roof - Skylights, Chimneys & Other Roof Penetrations: Metal Chimney Rust
☐ Roof - Skylights, Chimneys & Other Roof Penetrations: Chimney Flue Cracked
☐ Roof - Coverings: Damaged (General)
☐ Roof - Coverings: Improper/Incomplete Nailing
☐ Plumbing - Water Supply, Distribution Systems & Fixtures: Bathroom Fixture
☐ Heating - Distribution Systems: Return Air System Missing/Insufficient
☐ Heating - Equipment: Needs Servicing/Cleaning
☐ Heating - Equipment: Manifold Dirty
17512 85 Ave NW Srinivas Mandapaka
InspecUs Page 4 of 31
In AttendanceClient, Home Owner
OccupancyFurnished, Occupied, Stored Item
StyleBungalow
Temperature (approximate)2 Celsius (C)
Type of BuildingSingle Family
Weather ConditionsClear, Snow
Notes All your inspection photos Here
1: INSPECTION DETAILS
Information
17512 85 Ave NW Srinivas Mandapaka
InspecUs Page 5 of 31
Inspection MethodRoof, Walked
Roof Type/StyleGable
Roof Drainage Systems: GutterMaterial
Aluminum
Flashings: MaterialAluminum
Coverings: MaterialAsphalt
2: ROOFIN NI NP R
2.1 Coverings X X
2.2 Roof Drainage Systems X X
2.3 Flashings X
2.4 Skylights, Chimneys & Other Roof Penetrations X XIN = Inspected NI = Not Inspected NP = Not Present R = Recommendations
Information
Recommendations
2.1.1 Roof Drainage Systems
DEBRISEAST WEST
Debris has accumulated in the gutters. Recommend cleaning to facilitate water flow.Here is a DIY resource for cleaning your gutters.
RecommendationContact a qualified roofing professional.
Maintenance Item
2.1.2 Roof Drainage Systems
GUTTER IMPROPERLY SLOPEDWEST
Gutter are improperly sloped in areas, which could result in runoff drainage around the foundation andpossible structural shifting. Recommend qualified roofing or gutters contractor repair.
RecommendationContact a qualified roofing professional.
Recommendation
2.1.3 Roof Drainage Systems
UNDERGROUND ROOF DRAINAGEUnderground roof drainage not in used- recommend covering openings to avoid accumulating water nearhouse as its undetermined of its operation.
Recommendation
17512 85 Ave NW Srinivas Mandapaka
InspecUs Page 6 of 31
2.2.1 Skylights, Chimneys & Other Roof Penetrations
CHIMNEY FLUE CRACKEDWEST
The chimney flue had one or more cracks as per seller which can lead to further damage to the chimneystructure. Recommend a qualified contractor repair. observed not in used.
RecommendationContact a qualified roofing professional.
Recommendation
2.2.2 Skylights, Chimneys & Other Roof Penetrations
CHIMNEY REPOINT NEEDEDSOUTH
Joints in the masonry have deteriorated and should be repointed. (Repointing is the restoration of themortar joints in the masonry).
RecommendationContact a qualified repair chimney contractor.
Maintenance Item
2.2.3 Skylights, Chimneys & Other Roof Penetrations
METAL CHIMNEY RUSTEAST
The metal chimney shows evidence of rust and/or rusting. Recommend monitoring the chimney whichmay have to be replaced at some point.
RecommendationContact a qualified repair chimney contractor.
IMMEDIATE/SAFETY ITEM
17512 85 Ave NW Srinivas Mandapaka
InspecUs Page 7 of 31
2.4.1 Coverings
DAMAGED (GENERAL)ROOF
Roof coverings observed signs of deterioration, It's normal at age 19yrs as per seller. Recommend replacingwithin 3 to 5 years and also a qualified roofing professional evaluate and repair.
RecommendationContact a qualified roofing professional.
Recommendation
2.4.2 Coverings
IMPROPER/INCOMPLETE NAILINGROOF
Major Defects -Roof coverings showed signs of improper installation and fastening and missing flashing.Recommend a qualified roofing contractor evaluate and repair.
RecommendationContact a qualified roofing professional.
IMMEDIATE/SAFETY ITEM
17512 85 Ave NW Srinivas Mandapaka
InspecUs Page 8 of 31
Inspection MethodVisual
Decks, Balconies, Porches &Steps: Appurtenance
Deck, Front Porch, Patio
Decks, Balconies, Porches &Steps: Material
Wood
Walkways, Patios & Driveways:Driveway Material
Concrete
Exterior Doors: Exterior EntryDoor
Wood
Siding, Flashing & Trim: SidingMaterial
Stucco, Vinyl
Siding, Flashing & Trim: SidingStyle
Channel
3: EXTERIORIN NI NP R
3.1 Siding, Flashing & Trim X X
3.2 Exterior Doors X X
3.3 Walkways, Patios & Driveways X X
3.4 Decks, Balconies, Porches & Steps X X
3.5 Eaves, Soffits & Fascia X X
3.6 Vegetation, Grading, Drainage & Retaining Walls X XIN = Inspected NI = Not Inspected NP = Not Present R = Recommendations
Information
Recommendations
3.1.1 Vegetation, Grading, Drainage & Retaining Walls
NEGATIVE GRADINGEAST ,SOUTH AND NORTH
Grading is sloping towards the home in some areas. This could lead to water intrusion and foundationissues. Recommend qualified landscaper or foundation contractor regrade so water flows away fromhome.Here is a helpful article discussing negative grading.
RecommendationContact a qualified landscaper or gardener.
IMMEDIATE/SAFETY ITEM
17512 85 Ave NW Srinivas Mandapaka
InspecUs Page 9 of 31
3.1.2 Vegetation, Grading, Drainage & Retaining Walls
STANDING WATERSOUTH FRONT OF THE HOUSE
Standing water observed, which could indicate poor drainage and/or grading. Recommend monitor and/orhave landscaper correct.Here is a resource on dealing with standing water in your yard.
RecommendationContact a qualified landscaper or gardener.
IMMEDIATE/SAFETY ITEM
3.2.1 Eaves, Soffits & Fascia
FASCIA - ROTTEDNORTH SOUTH WEST EASTOne or more sections of the fascia are rotted. Recommend qualified roofer evaluate, replace & repair.RecommendationContact a qualified roofing professional.
IMMEDIATE/SAFETY ITEM
17512 85 Ave NW Srinivas Mandapaka
InspecUs Page 10 of 31
3.3.1 Decks, Balconies, Porches & Steps
DECK - ROTTED BOARDSNORTHOne or more deck boards are showing signs of rot. Recommend a qualified deck contractor replace.RecommendationContact a qualified deck contractor.
Maintenance Item
3.3.2 Decks, Balconies, Porches & Steps
GUARDRAILFRONT DOORGuardrail Missing at front porch
IMMEDIATE/SAFETY ITEM
3.4.1 Walkways, Patios & Driveways
DRIVEWAY CRACKING - MAJORSOUTH
Major cracks observed. Recommend concrete contractor evaluate and replace.
RecommendationContact a qualified concrete contractor.
IMMEDIATE/SAFETY ITEM
17512 85 Ave NW Srinivas Mandapaka
InspecUs Page 11 of 31
3.4.2 Walkways, Patios & Driveways
DRIVEWAY TRIP HAZARDSOUTHTrip hazards observed. Patch or repair recommended.RecommendationRecommended DIY Project
IMMEDIATE/SAFETY ITEM
3.5.1 Exterior Doors
PAINT/REFINISH NEEDEDSOUTH AND WEST
Door finish is worn. Recommend refinish and/or paint to maximize service life.Here is a DIY article on refinishing a wood door.
RecommendationContact a qualified door repair/installation contractor.
Maintenance Item
3.5.2 Exterior Doors
WEATHERSTRIPPING NOT PRESENTWEST , SOUTH
Door is missing standard weatherstripping. This can result in significant energy loss and moistureintrusion. Recommend installation of standard weatherstripping.Here is a DIY guide on weatherstripping .
RecommendationContact a qualified door repair/installation contractor.
Maintenance Item
3.5.3 Exterior Doors
EGRESS WINDOWgress windows are not as standard, recommend upgrading withwindow well.
Recommendation
17512 85 Ave NW Srinivas Mandapaka
InspecUs Page 12 of 31
Not a frost-free faucet,
3.6.1 Siding, Flashing & Trim
EVIDENCE OF WATER INTRUSIONNORTH
Siding showed signs of water intrusion. This could lead to further siding deterioration and/or mold.Recommend a qualified siding contractor evaluate and repair.
RecommendationContact a qualified professional.
Maintenance Item
17512 85 Ave NW Srinivas Mandapaka
InspecUs Page 13 of 31
Inspection MethodVisual
Floor Structure: MaterialInaccessible
Floor Structure: Sub-floorPlywood
Foundation: MaterialConcrete
4: BASEMENT, FOUNDATION, CRAWLSPACE &STRUCTURE
IN NI NP R
4.1 Foundation X X
4.2 Basements X X
4.3 Floor Structure X
4.4 Wall Structure X X
4.5 Ceiling Structure XIN = Inspected NI = Not Inspected NP = Not Present R = Recommendations
Information
Recommendations
4.2.1 Wall Structure
EVIDENCE OF WATER INTRUSIONBASEMENT ROOM
Wall structure showed signs of water intrusion, which could lead to more serious structural damage.Recommend a qualified contractor identify source or moisture and remedy.
RecommendationContact a qualified structural engineer.
IMMEDIATE/SAFETY ITEM
17512 85 Ave NW Srinivas Mandapaka
InspecUs Page 14 of 31
4.5.1 Foundation
FOUNDATION CRACKS - MINORSOUTH, WEST & EAST
Minor cracking was noted at the foundation. This is common as concrete ages and shrinkage surfacecracks are normal. Recommend monitoring for more serious shifting/displacement. Here is an informational article on foundation cracks.
RecommendationRecommended DIY Project
Recommendation
17512 85 Ave NW Srinivas Mandapaka
InspecUs Page 15 of 31
Distribution Systems: DuctworkNot Visible
Equipment: Energy SourceNatural Gas
Equipment: Heat TypeForced Air
AFUE Ratinghe efficiency of a 1976 natural draft, continuous pilot light, heavy duty heat exchanger natural gasfurnace would have been anywhere between 56% to 70% AFUE.
AFUE (Annual fuel utilization efficiency) is a metric used to measure furnace efficiency in converting fuel toenergy. A higher AFUE rating means greater energy efficiency. 90% or higher meets the Department of Energy'sEnergy Star program standard.
5: HEATINGIN NI NP R
5.1 Equipment X X
5.2 Normal Operating Controls X
5.3 Distribution Systems X X
5.4 Vents, Flues & Chimneys X
5.5 Presence of Installed Heat Source in Each Room XIN = Inspected NI = Not Inspected NP = Not Present R = Recommendations
Information
Recommendations
5.3.1 Distribution Systems
RETURN AIR SYSTEM MISSING/INSUFFICIENTBASEMENT
Return air registers were missing or insufficient. This can result in poor heating efficiency. Recommend aqualified HVAC contractor evaluate and remedy.
RecommendationContact a qualified HVAC professional.
Recommendation
5.5.1 Equipment
MANIFOLD DIRTYBASEMENT
Manifold was dirty. Cleaning manifolds will result in better air quality.
RecommendationContact a qualified HVAC professional.
IMMEDIATE/SAFETY ITEM
17512 85 Ave NW Srinivas Mandapaka
InspecUs Page 16 of 31
5.5.2 Equipment
NEEDS SERVICING/CLEANINGBASEMENT
Furnace should be cleaned and serviced annually. Recommend a qualified HVAC contractor clean, serviceand certify furnace.Here is a resource on the importance of furnace maintenance.
RecommendationContact a qualified HVAC professional.
Recommendation
17512 85 Ave NW Srinivas Mandapaka
InspecUs Page 17 of 31
6: COOLINGIN NI NP R
6.1 Cooling Equipment X
6.2 Normal Operating Controls X
6.3 Distribution System X
6.4 Presence of Installed Cooling Source in Each Room XIN = Inspected NI = Not Inspected NP = Not Present R = Recommendations
17512 85 Ave NW Srinivas Mandapaka
InspecUs Page 18 of 31
FiltersNone
Water SourcePublic
Hot Water Systems, Controls,Flues & Vents: PowerSource/Type
Gas
Hot Water Systems, Controls,Flues & Vents: CapacityBasement
40 gallons
Hot Water Systems, Controls,Flues & Vents: Location
Basement
Water Supply, DistributionSystems & Fixtures: DistributionMaterial
Copper
Water Supply, DistributionSystems & Fixtures: WaterSupply Material
Copper
Drain, Waste, & Vent Systems:Drain Size
Unknown
Drain, Waste, & Vent Systems:Material
UnknownRecommend asking the seller forDrainage cleanout location.
Main Water Shut-off Device:Location
Basement
Hot Water Systems, Controls, Flues & Vents: ManufacturerRheem
I recommend flushing & servicing your water heater tank annually for optimal performance. Water temperatureshould be set to at least 120 degrees F to kill microbes and no higher than 130 degrees F to prevent scalding. Here is a nice maintenance guide from Lowe's to help.
7: PLUMBINGIN NI NP R
7.1 Main Water Shut-off Device X
7.2 Drain, Waste, & Vent Systems X X
7.3 Water Supply, Distribution Systems & Fixtures X X
7.4 Hot Water Systems, Controls, Flues & Vents X X
7.5 Fuel Storage & Distribution Systems X
7.6 Sump Pump XIN = Inspected NI = Not Inspected NP = Not Present R = Recommendations
Information
17512 85 Ave NW Srinivas Mandapaka
InspecUs Page 19 of 31
Recommendations
7.4.1 Water Supply, Distribution Systems & Fixtures
BATHROOM FIXTUREBASEMENT MAIN FLOOR FULL BATHROOM ENSUITE BATHROOM
Toilet and sink are loose and/or leaking at the base. Recommend a qualified plumber evaluate and repairto prevent further water damage.
RecommendationContact a qualified plumbing contractor.
IMMEDIATE/SAFETY ITEM
17512 85 Ave NW Srinivas Mandapaka
InspecUs Page 20 of 31
Branch Wiring Circuits, Breakers& Fuses: Branch Wire 15 and 20AMP
Aluminum, Copper
Branch Wiring Circuits, Breakers& Fuses: Wiring Method
Surface Mounted Distribution
Main & Subpanels, Service &Grounding, Main OvercurrentDevice: Main Panel Location
Right, Basement
Main & Subpanels, Service &Grounding, Main OvercurrentDevice: Panel Capacity
125 AMP
Main & Subpanels, Service &Grounding, Main OvercurrentDevice: Panel Manufacturer
Unknown
Main & Subpanels, Service &Grounding, Main OvercurrentDevice: Panel Type
Circuit Breaker
Main & Subpanels, Service &Grounding, Main OvercurrentDevice: Sub Panel Location
Basement, Right
Service Entrance Conductors:Electrical Service Conductors
Below Ground, 220 Volts
8: ELECTRICALIN NI NP R
8.1 Service Entrance Conductors X
8.2 Main & Subpanels, Service & Grounding, Main Overcurrent Device X X
8.3 Branch Wiring Circuits, Breakers & Fuses X X
8.4 Lighting Fixtures, Switches & Receptacles X X
8.5 GFCI & AFCI X X
8.6 Smoke Detectors X X
8.7 Carbon Monoxide Detectors X XIN = Inspected NI = Not Inspected NP = Not Present R = Recommendations
Information
Recommendations
8.1.1 Carbon Monoxide Detectors
RECOMMEND INSTALLATIONBASEMENT, MAIN FLOORRecommend Installation CO2 detector in utilities room and mainfloor bedroom
IMMEDIATE/SAFETY ITEM
8.2.1 Smoke Detectors
RECOMMEND INSTALLATIONBASEMENT KITCHENRecommend Installation smoke detector in basement kitchen and utilities room
IMMEDIATE/SAFETY ITEM
17512 85 Ave NW Srinivas Mandapaka
InspecUs Page 21 of 31
8.3.1 GFCI & AFCI
NO GFCI PROTECTION INSTALLEDENSUITE BATHROOM KITCHEN BASEMENT KITCHEN BASEMENT FULL BATHROOM
No GFCI protection present in all locations. Recommend licensed electrician upgrade by installing groundfault receptacles in all locations.Here is a link to read about how GFCI receptacles keep you safe.
RecommendationContact a qualified electrical contractor.
Recommendation
8.4.1 Lighting Fixtures, Switches & Receptacles
COVER PLATES DAMAGEDBASEMENT BEDROOMOne or more receptacles have a damaged cover plate. Recommend replacement.RecommendationContact a qualified electrical contractor.
IMMEDIATE/SAFETY ITEM
8.5.1 Branch Wiring Circuits, Breakers & Fuses
ALUMINUM BRANCH CIRCUITSATTIC, BASEMENT
Aluminum wire appears to be installed on branch electrical circuits in the subject premises. These singlestrand, branch circuit aluminum wires were used widely in houses during the mid 1960s and 1970s.According to the U.S. Consumer Product Safety Commission, problems due to expansion can causeoverheating at connections between the wire and devices (switches and outlets) or at splices, which hasresulted in fires. For further information on aluminum wiring contact the U.S. Consumer Product SafetyCommission via the Internet at http://www.cpsc.gov/ . It is recommended that the electrical system beevaluated by a licensed electrician.
RecommendationContact a qualified electrical contractor.
Recommendation
17512 85 Ave NW Srinivas Mandapaka
InspecUs Page 22 of 31
8.6.1 Main & Subpanels, Service & Grounding, Main Overcurrent Device
BREAKER INCORRECTLY WIREDBASEMENT
Basement Range Circuit breaker was incorrectly wired/installed. This indicates that work was probably notperformed by a licensed electrician and poses a safety hazard. Recommend that a licensed electriciancheck the entire panel and repair and replace as need.
RecommendationContact a qualified electrical contractor.
IMMEDIATE/SAFETY ITEM
17512 85 Ave NW Srinivas Mandapaka
InspecUs Page 23 of 31
Dryer Power Source220 Electric
Dryer VentMetal (Flex)
Flooring InsulationNone
Ventilation: Ventilation TypeRidge Vents, Soffit Vents,Turbines
Attic Insulation: R-value12
Attic Insulation: Insulation TypeBatt
infestationAttic
Observed droppings and traps in attic, Recommend qualified Pets control professional for correction.
Use a sealant to block off all air flow, and to discourage mice from trying to get inside (they can smell air comingthrough a gap). This is an essential part of the mouse removal from the attic process. THIRD: Only AFTEReverything is sealed should you bother to trap and remove the mice. Set mouse snap traps.
9: ATTIC, INSULATION & VENTILATIONIN NI NP R
9.1 Attic Insulation X X
9.2 Vapor Retarders (Crawlspace or Basement) X
9.3 Ventilation X X
9.4 Exhaust Systems XIN = Inspected NI = Not Inspected NP = Not Present R = Recommendations
Information
Recommendations
9.2.1 Ventilation
ATTIC VENTILATION INSUFFICIENTNORTH
Attic venting was insufficient at time of inspection. Modern standards recommend 1.5 square feet ofventing area for every 300 square feet of attic floor space. Recommend an attic contractor evaluate andremedy.
RecommendationContact a qualified professional.
Recommendation
17512 85 Ave NW Srinivas Mandapaka
InspecUs Page 24 of 31
9.4.1 Attic Insulation
INSUFFICIENT INSULATIONATTIC
Major defects - Insulation depth was inadequate, missing in one and more places. Recommend a qualifiedattic insulation contractor install additional insulation.
RecommendationContact a qualified insulation contractor.
Recommendation
17512 85 Ave NW Srinivas Mandapaka
InspecUs Page 25 of 31
Countertops & Cabinets:Countertop Material
Laminate
Countertops & Cabinets:Cabinetry
Laminate, Wood
Ceilings: Ceiling MaterialGypsum Board, Plaster
Walls: Wall MaterialDrywall, Paneling, Wood
Floors: Floor CoveringsLaminate
Windows: Window TypeSingle Pane, Sliders
Windows: Window ManufacturerUnknown
Ceilings: InsulationLiving Room Bedroom Basement
missing insulation one or more places, Recommend upgrading for better air quality and energy bills.
10: DOORS, WINDOWS & INTERIORIN NI NP R
10.1 Doors X X
10.2 Windows X X
10.3 Floors X X
10.4 Walls X X
10.5 Ceilings X X
10.6 Steps, Stairways & Railings X X
10.7 Countertops & Cabinets X XIN = Inspected NI = Not Inspected NP = Not Present R = Recommendations
Information
17512 85 Ave NW Srinivas Mandapaka
InspecUs Page 26 of 31
Recommendations
10.1.1 Countertops & Cabinets
CABINET HINGE LOOSEBASEMENT MAIN FLOOR KITCHEN
One or more cabinet hinges were loose. Recommend a qualified handyman or cabinet contractor repair. Here is a helpful DIY article on cabinet repairs.
RecommendationContact a qualified cabinet contractor.
Recommendation
10.2.1 Steps, Stairways & Railings
NO HANDRAILBASEMENT
Staircase had no handrails. This is a safety hazard. Recommend aqualified handyman install a handrail.
RecommendationContact a qualified handyman.
Recommendation
10.3.1 Ceilings
MINOR DAMAGEMinor damage or deterioration to the ceiling was visible at the time of the inspection.
RecommendationContact a qualified professional.
Recommendation
17512 85 Ave NW Srinivas Mandapaka
InspecUs Page 27 of 31
10.3.2 Ceilings
POSSIBLE MOLDATTIC BASEMENT MAIN FLOORThere are possible signs of fungi growth on ceiling. It is unknown if this is a safety hazard. Recommend aqualified mold inspector evaluate.RecommendationContact a qualified mold inspection professional.
IMMEDIATE/SAFETY ITEM
10.3.3 Ceilings
STAIN(S) ON CEILINGBASEMENT MAIN FLOOR
There is a stain on ceiling/wall that requires repair and paint. Source of staining should be determined.
RecommendationContact a qualified professional.
Recommendation
10.4.1 Walls
MOISTURE DAMAGEBASEMENT MAIN FLOOR
Stains on the walls visible at the time of the inspection appeared to be the result of moisture intrusion. Thesource of moisture may have been corrected. Recommend further examination by a qualified contractor toprovide confirmation.
RecommendationContact a qualified professional.
Recommendation
10.5.1 Floors
DAMAGED (GENERAL)MAIN FLOOR BASEMENT
The home had general moderate damage and unprofessional finish, visible at the time of the inspection.Recommend service by a qualified contractor.
RecommendationContact a qualified cleaning service.
IMMEDIATE/SAFETY ITEM
17512 85 Ave NW Srinivas Mandapaka
InspecUs Page 28 of 31
10.5.2 Floors
MODERATE WEARBASEMENT MAIN FLOOR
Floors in the home exhibited moderate surface wear along major paths of travel. Recommend a qualifiedflooring contractor evaluate for possible re-finish.
RecommendationContact a qualified flooring contractor
Recommendation
10.6.1 Windows
DAMAGEDNORTH SOUTH WEST EASTMost of the windows are very old and not effective, Recommend upgrading in near future to avoidmoisture intrusion and loss of energy.One or more windows appears to have damage, but are operational. Recommend a window professionalrepair, lubricate & adjust as necessary.RecommendationContact a qualified window repair/installation contractor.
IMMEDIATE/SAFETY ITEM
10.7.1 Doors
DOOR KNOBS MISSINGBASEMENT BEDROOMDamage Missing knobs in the basement. Recommend Correction
IMMEDIATE/SAFETY ITEM
17512 85 Ave NW Srinivas Mandapaka
InspecUs Page 29 of 31
17512 85 Ave NW Srinivas Mandapaka
InspecUs Page 30 of 31
Range/Oven/Cooktop:Range/Oven Energy Source
Electric
Range/Oven/Cooktop: ExhaustHood Type
Vented
11: BUILT-IN APPLIANCESIN NI NP R
11.1 Dishwasher X
11.2 Refrigerator X
11.3 Range/Oven/Cooktop X
11.4 Garbage Disposal XIN = Inspected NI = Not Inspected NP = Not Present R = Recommendations
Information
17512 85 Ave NW Srinivas Mandapaka
InspecUs Page 31 of 31