92
Catalogue 2010 Residential Light Commercial Commercial

Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Catalogue 2010Residential LightCommercial Commercial

Page 2: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative
Page 3: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Advanced air conditioning technologyResearch and technological innovation have been the goals of Mitsubishi Heavy Industries for over a century and these have been translated into the excellent results obtained in the air conditioning market. The perfect harmony between energy, technology and innovation is manifested in the production of air conditioners designed to meet the engineering requirements of the residential, commercial and industrial sectors. State-of-the-art solutions applied to top quality products guarantee comfort, energy efficiency, and quality of life.

Range 2010

For a bettertomorrow

Profile 2-3

Range 2010 4-5

Residential andLight commercial Range

6-47

Air to Water Heat PumpHYDROLUTION

48-49

Commercial Range 50-82

Controls 83

Individual Controls 84

Optional Controls 85

Superlink II 86-88

Page 4: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

The origin of the brand dates back to the last decade of the nineteenth century in Nagasaki, where the first big shipyard was established to produce ships for the Japanese navy. Shipbuilding is still one of the most important sectors for Mitsubishi Heavy Industries. Subsequently Mitsubishi implemented a progressive diversification and extension of its activity in heavy industry, as well as in the airplane, rail and car sectors, becoming the biggest private company in Japan in the 1930’s. Mitsubishi Heavy Industries still operates in the car sector through its subsidiary company Mitsubishi Motors.

In the post-war period there was a organised process of corporate downsizing by American industry for the protection of the same.

The competitor Mitsubishi Electric was set up in 1921 as one of these spin offs, producing a limited number of products (electrical engines for boats and fans) and keeping the three-pointed diamond as its logo, just like the parent company.

The current need for alternative energy resources in fact, sees Mitsubishi Heavy Industries constantly committed to searching for state-of-the-art solutions that can preserve the delicate balance of the ecosystem both today and in the future

The advent of the third millennium saw Mitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative energy sources and space exploration, with a constant commitment to guarantee development whilst keeping man and technology in perfect harmony.

The global activity ofMitsubishi Heavy Industries, Ltd.

Page 5: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

The global activity ofMitsubishi Heavy Industries, Ltd.

• Chemical Plants• Wind Tunnels/Test Rigs• Casting and Foundry

Equipment• Strip Mills• Cement Plant • Industrial Robots• Injection Moulding Machines• Pulp & Paper Machinery• Production of Corrugated

Packaging• Box Making Machines• Machine Tools

Resources/Energy

• Unloader & Container Cranes• Mechanical Parking Facilities• Integrated Automated Storage

Systems• Rubber & Tyre Manufacturing

Plant• Skyrails• Monorail Cars• New Transportation Systems• Passenger Boarding Bridges• Toll Collection Machine

Systems• Forklift Trucks• Helicopters• Aircraft• Railway Maintenance

Equipment• LNG Carriers• Container Ships

Transportation

• Air conditioners for residential and commercial applications

• Automotive air conditioners• Refrigeration units• Dry cleaning machines • Equipment for the food

industry• Cruise ships • Multipurpose domes

Comfort

• Photovoltaic modules with thin film technology• Crude Oil Storage Barges• LNG Tanks• Boilers & Turbines• Oil Production Plants • Thermal Power Plants• Combined Cycle Plants• Fuel Cells• Water Turbines• Wind Turbines• Geothermal Power Plants• PWR Nuclear Power Plants• Uranium Enrichment

Equipment• Co-Generation Systems

Industry

• Spillway Radial Gates• Steel Bridges• Penstocks• Desalination Plants• Logistics and Transportation• Turbines• Cabling Systems

Local development

• Oceanographic research ships• Deepsea research vehicles• Communication satellites and

rockets• Space transportation• Rockets and engines

Research and development

• Ultra-High Steel Stacks• Refuse Incineration Plants• Night Soil Treatment Plants• Fluidized Incinerators• CFC Collecting Equipment

Environment

• Submarines• Naval vessels• Jet fighters• Helicopters• Missiles

Defence

Page 6: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

2010 Range

Mitsubishi Heavy Industries air-conditioners are designed and developed to ensure quality of air and well-being. The anti-bacterial treatment of the fan, together with the united action of special filters help in neutralizing bacteria, viruses and allergens and keeping air in the room clean and safe.

Quality of air and well-being

Sleep mode ensures comfort and well-being during the night: the room temperature is automatically controlled and decreased, so to balance the natural drop of the body temperature while sleeping. Furthermore, Mitsubishi Heavy Industries air-conditioners show automatic operation mode – cooling/heating/dry/air flow/clean air – and low noise levels that help in having the best standard of comfort at any time.

Comfort

High efficiency

Modern, high performing and compact: Mitsubishi Heavy Industries air-conditioners can enhance all areas requiring conditioning systems and ensure comfort, energy saving and reliability, fully respecting the environment.

Energy saving

Most of Mitsubishi Heavy Industries air-conditioners reach the highest energy efficiency class A/A – in cooling and heating – thus ensuring the highest energy saving level and the best energy efficiency.

The research laboratories of Mitsubishi Heavy Industries have always been committed to the study and applications of new technologies, in order to develop high quality products in the full respect for the environment.

DC PAM Inverter technology ensures the highest energy efficiency and the lowest power consumption. Compared to a constant speed system, the compressor output can ensure quick heating after the start up and attain a set temperature more quickly. Then the air-conditioner can slow down its compressor speed to save energy , keeping comfortable conditions.

Page 7: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

CommercialResidential andLight commercial• 5 Monosplit lines• 2 Multisplit lines• Single module Hydrolution• Depth of range• High energy saving with COP and

EER values at the highest level in the world

These are the characteristics that makethe new Residential and Light Commercial Range, unique in content, energy efficiency and application flexibility.

Today, for residential applications, Mitsubishi Heavy Industries also offers Hydrolution.This Air to Water Heat Pump is a complete modern system for heating, cooling and producing hot sanitary water for small houses, offering effective energy saving and reducing carbon dioxide emission. Hydrolution is safe and economical with integrated hot water heater, immersion heater, circulating pump and climate system within the indoor unit.

• 2 product lines • depth of range • High COP values The new Hyper DC Inverter line also shows:

• increased length of splitting • constant heating capacity with

decreasing outdoor temperature

Reliable in energy performance and advanced in technology, the air conditioners of the Commercial Range, guarantee high efficiency and low consumption for flexible applications in offices, shops and the tertiary.

Page 8: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

The PAM DC Inverter system guarantees high energy efficiency thanks to its new motor with permanent magnets, which increases low pressure electrical efficiency thanks to the reduced interior attrition. The machine limits energy absorption when it is not necessary (e.g. whilst maintaining temperature) or increases its absorption when the desired climatic conditions need to be reached rapidly (e.g. during start up).

High Efficiency

The new inverter control applies the latest developments in vector control to attain high efficiency.• Smooth operation from low to high

speed.• Smooth Sine Wave voltage is

achieved.• Improved energy efficiency even at

low rotational speeds (except for SRK ZE-S1).

Inverter Control (Vector)

The printed wiring board of the outdoor unit is coated by silicon, so that it can have a better tolerance for humidity and last longer (all SRC models).

Silicon-coated PCB

The research laboratories of Mitsubishi Heavy Industries have always been committed to the study and application of new technologies, whose results are high quality products guaranteeing high efficiency in the full respect for the environment.

Residential and Light commercial Range

Page 9: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

5,5

5,0

4,5

4,0

3,5

3,0

2,5

5,56

5,71

5,26 5,20

4,48

4,14

4,44

3,85 4,07

3,23

3,62

3,21

The new radial shape grill has been developed in order to realize a natural air flow sent by the propeller fan along with it. The airflow is very smooth with the least air resistance and the decrease of the motor load leads to an improvement in the energy efficiency.

Shape grill

Steel sheet is applied at the base of the outdoor units and can ensure a great steadiness to the anchor bolt. It is coated with ZAM, a coined name applied to hot-dipped zinc-aluminum-magnesium-alloy, having higher corrosion resistance properties compared to conventional materials. ZAM is a registered trademark of Nissin Steel Co., Ltd.

Steel sheet

Matching the new design of the propeller fan with the features of the fan motor led to keep the same capacity as that of previous models with lower electrical consumption. The synergy effect with the leaf shape grill provides an improvement of energy efficiency by 5% compared to previous models (SRC 40/50/60 ZIX-S models).

New propeller fan

Scroll compressor helps in improving energy efficiency and in reducing vibrations and sound levels. Furthermore, the use of a neodymium magnet applied in the motor produces huge energy, thus reducing the energy loss occurred during the compression phase (SRC 40/50/60 ZIX-S models).

Scroll compressor

High performance, maximum reliability and long life, silent operation and an elegant and sophisticated design: these are the main features of a high-grade air-conditioning system. All models of the Ultra DC Inverter Flex and Hyper DC Inverter lines feature an extremely high energy efficiency rate, and all are class A for COP and EER values.

HIGH COP: efficiency and energy saving

Page 10: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

CFD (Computational fluids dynamics) technology, used in the blade shape design of jet engines, has been applied to air-conditioning, to develop air channels with an optimal air circulation system.The air flow obtained thanks to this system enables the diffusion of a large volume of air, with extremely low energy consumption, as there is a marked reduction in the stagnation of collected air flow, thus reducing energy waste appreciably. The air flow is then uniform, silent, and can reach long

Jet Air Scroll

distances, i.e., perfect for large air-conditioned areas.

Ideal temperatures every day, accurate and modern design, quality of air, silent operation and energy saving are the elements Mitsubishi Heavy Industries offers to achieve the desired well-being.

Slow Fast

The increased surface of the louvers helps in the distribution of the air flow, which is uniform, quiet and reaches long distance points from the blower.

Long reach flow

SRK 50~60 ZJX-S(cooling)

SRK 71 ZE-S1(cooling)

Page 11: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Three-dimensional ventilation

The innovative 3D Ventilation system of Mitsubishi Heavy Industries characterizes all wall-mounted models (except for HG-S). This system can be selected both in manual and automatic mode, enabling a better distribution and de-stratification of treated air, in the air-conditioned area. In manual mode, thanks to the 2 dedicated buttons on the remote control, 7 different settings can be selected, for horizontal and vertical flow, besides SWING mode (continuous motion of the louvers).

Vertical movement

Horizontal positions

The 3D Auto system is a programmable mode, thanks to one only key on the remote control: 3 motors – one for horizontal movement and 2 for vertical movement – allow you to have 3 independent air flow controls. Air flow is uniform, silent and can reach long distances from the indoor unit. Air flow, in the air-conditioned room, is uniformly sent, on the basis of the programmed 3D ventilation automatic mode (ZJ-S, ZJX-S models).

Three-dimensional ventilation:AUTO mode

By using the IR controller it is possible to select (air flow, up/down) and set (3D auto) air scroll and direction swing (ZJ-S, ZJX-S models; SRK 71 ZE-S1 just has the manual setting).

Selection and setting by IR controller

The redesigned size and shape of the new louver improves 3D air flow. The thinner profile and the addition of 80% surface area helps in increasing the air flow volume and in improving the lateral swinging (ZJX-S models).

New size and shape of the louver

previous model new model

Page 12: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Anti-allergenic filter

The new anti-allergenic filter, mounted on every model of the DC Inverter Monosplit Smart line, is a unique brand-new feature, resulting from Mitsubishi Heavy Industries research, and which is in a position to neutralize the action of pollen, mite, bacteria and many other allergens which can be found in the air. Neutralization capacity is given by the combined action of urea and natural enzymes: treated air is free from impurities, and your health is protected. The self-cleaning function of this filter can be selected by pressing the “ALLERGEN CLEAR” button.

From the Mitsubishi Heavy Industries laboratories, another revolutionary product for air purification: the natural sterilizing enzyme filter, which, unlike traditional filters, does not possess any chemical compounds or heavy metals.The enzymes’ action is localized, without any risk of materials being irradiated or dispersed in the environment. The enzymes attack the micro-organisms that are in the air, and that can cause many pathologies transmitted through the air, by trapping them into the filter and destroying them.

The photocatalytic filter keeps air clean and pleasant, thanks to its double action: filtering and deodorizing. The filter is self-regenerating, simply washing it in water and then letting it dry in the sunlight.

Photocatalytic filter

Natural enzyme filter

The plastic component of the fan’s blades is made of anti-bacterial material, so to better resist against moulds and germs proliferation. All models of the Ultra DC Inverter Flex and Hyper DC Inverter lines feature this application.

Anti-bacterial fan treatment

Page 13: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Thanks to the self- regenerating function, all components of indoor units are submitted to an automatic sanitization process, stopping mould proliferation and getting rid of the rank smell they produce.This function can be selected by pressing the “clean” switch on the remote control, and starts at the end of the machine’s operating cycle. The operation can last 2 hours max., but it can be nevertheless interrupted, by pressing the “on/off” key on the remote control.

Self Clean function: automatic sanitization against moulds

This is another exclusive feature of Mitsubishi Heavy Industries, in a position to neutralize the effects of the pathogen agents that lay on the surface of the allergenic filter. The filter can be cleaned by pressing the “allergen” button, on the remote control. The operation can last about 1h 30’, and then automatically stops.

Allergen Clear System: sanitization against allergens

Normal operation

Automatic switch-off

Air treatment functions related to each model of monosplit and multisplit lines are shown in the chart

FunctionsSRK ZJX-S SRF ZJX-S SRK ZGX-S SRK ZE-S1 SRK ZJ-S SRR ZJ-S SRK ZG-S SRK HG-S

Sanitizations against moulds (Self Clean)

Sanitizations against allergens (Allergen Clear)

Antiallergenic filter

Natural enzyme filter

Photocatalytic filter

3D ventilation

Page 14: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Residential andLight commercial Range

Modern and elegant design, high energy performance and silence are the hallmarks of the Hyper DC Inverter range.All units feature high energy efficiency coefficients and extremely low sound levels.

Class COP > 5,00Compact, stylish and practical with regards to application needs in residential, high residential and light commercial, environments, the air conditioners in the Ultra DC Inverter Flex range guarantee high energy performance, application flexibility and energy savings. The units in this range - wall-mounted, console, cassette 60x60 and duct low static pressure - can be freely combined with SCM units within the Multi DC Inverter Hyper system.

The heat pump air-conditioners in Mitsubishi Heavy Industries’ Residential and Light Commercial range are beautifully detailed and designed to ensure maximum energy savings. The monosplit in the Ultra DC Inverter Flex, Hyper DC Inverter, DC Inverter Plus, Flat DC Inverter and Constant Speed ranges, mostly in Energy Class A/A, provide a personalized response to any need for residential comfort.

Class COP > 4,50

In the line up the indoor units that can also be

used in the

Line

Model SRK ZJX-SWall-mounted

SRF ZJX-SConsole

FDEN VDCeiling

FDT VD4-ways cassette

84x84

FDTC VD4-ways cassette

60x60

SRR ZJ-SDucted low

FDUM VDDucted

medium

SRK-SRC ZGX-SWall-mounted

SRK-SRC ZJ-SWall-mounted

SRK-SRC ZG-SWall-mounted

SRK-SRC HG-SWall-mounted

MULTI DC INVERTER

HYPERsystem are highlighted

Page 15: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Slim and stylish, the new ZJ-S wall models in the Plus DC Inverter range are characterized by extremely high COP and EER and can be freely combined with SCM units within the Multi DC Inverter Hyper system.

Elegant, with modern and essential design, the wall models in the Flat DC Inverter range are characterized by a slim and compact line: a depth of only 19.9 cm provides great installation flexibility, capable of satisfying any residential requirements.

Created with the most traditional Constant Speed technology, the units in this range boast very high splitting lengths and Class A/A for power ratings of 2,0 and 2,6 kW: a solution which is reliable over time, capable of ensuring optimum comfort.

• 5 product lines• maximum application flexibility• high energy saving

Class COP > 4,00 Class COP > 3,61 Class COP > 3,61

Line

Model SRK ZJX-SWall-mounted

SRF ZJX-SConsole

FDEN VDCeiling

FDT VD4-ways cassette

84x84

FDTC VD4-ways cassette

60x60

SRR ZJ-SDucted low

FDUM VDDucted

medium

SRK-SRC ZGX-SWall-mounted

SRK-SRC ZJ-SWall-mounted

SRK-SRC ZG-SWall-mounted

SRK-SRC HG-SWall-mounted

Page 16: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

central control system that can be accessed online and can manage air conditioning systems in residential, commercial and industrial applications remotely. The integration within the Superlink II network is through the use of the SC-ADNA-E and SC-BIKN-E interface cards, see the appropriate section.

Class COP > 4,50The Multi DC Inverter Hyper range is an innovative multisplit system by Mitsubishi Heavy Industries designed to ensure full comfort and installation versatility, throughout the year. The outdoor units are available in 6 capacities and are able to combine up to 4 indoor units chosen from the Ultra DC Inverter DC Inverter Flex and Plus DC Inverter series, and various types of kW. The Multi DC Inverter Hyper series can be integrated within a Superlink II network, the exclusive

The range of multisplit air conditioners in the Multi DC Inverter Hyper and Multi DC Inverter Comfort lines, has evolved to adapt to different installation requirements: the application in medium and large residential spaces is accompanied by the possibility of a light commercial use. The Multi DC Inverter Hyper and Multi DC Inverter Comfort ranges are characterized by a wide range of indoor units that can provide an adequate response to all the demands of comfort and well-being.

Line

ModelUltra DC Inverter Flex Plus DC Inverter SKM ZG-S SRRM ZG-S STM ZF-S

SRK ZJX-SWall-mounted

SRF ZJX-SConsole

SRR ZJ-S Ductedmedium and low

FDTC VD 4-ways cassette 60x60

SRK ZJ-SWall-mounted

Wall-mounted Ducted mediumand low

4-wayscassette 60x60

k

W

2,0

2,5

2,8

3,5

5,0

6,0

7,1

Residential andLight commercial Range

Page 17: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Line

ModelOutdoor units

SCM ZJ-S SCM ZG-S

kW

4,0

4,5

5,0

6,0

7,1

8,0

• 2 product lines• depth of range• high COP values

The Multi DC Inverter Comfort series Mitsubishi Heavy Industries’ most traditional multisplit range: outdoor units in 5 capacities capable of combining up to 4 indoor units of different types and kW - wall mounted cassette and duct type units with low and medium static pressure. The Multi DC Inverter Comfort series can be integrated within a Superlink I network, for application see details in each product info sheet.

Class COP > 4,00

Line

ModelUltra DC Inverter Flex Plus DC Inverter SKM ZG-S SRRM ZG-S STM ZF-S

SRK ZJX-SWall-mounted

SRF ZJX-SConsole

SRR ZJ-S Ductedmedium and low

FDTC VD 4-ways cassette 60x60

SRK ZJ-SWall-mounted

Wall-mounted Ducted mediumand low

4-wayscassette 60x60

k

W

2,0

2,5

2,8

3,5

5,0

6,0

7,1

Page 18: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Wall mounted air-conditioners,5 capacities available (2,0~6,0 kW)

Energy Class A, both in cooling and in heating

Low sound level: 21 dB(A) only (2,0 kW)

Antibacterial treatment of the blower fan

Movable air inlet panelAutomatic opening of the front panel: the horizontal swing helps the air suction, minimizes the air resistance and lowers the threshold of sound levels. The flat shape of the panel enhances the modern and sophisticated design of the unit.

Superlink II connectionThe units can be connected to RC-E4 wired remote control and to Superlink II system, thanks to the optional interface kit SC-BIKN-E andSC-ADNA-E interface.

Long piping length: 30 m (5,0~6,0 kW)

Sophisticated and modern design

Operation range in heating and cooling at an outdoor temperature as low as -15° C

Wall-mounted SRK 20~60 ZJX-S

SRK 20 ZJX-S / SRC 20 ZJX-SSRK 25 ZJX-S / SRC 25 ZJX-SSRK 35 ZJX-S / SRC 35 ZJX-SSRK 50 ZJX-S / SRC 50 ZIX-SSRK 60 ZJX-S / SRC 60 ZIX-S

These indoor units can be coupled with the outdoor units

SCM ZJ-S from the Multi System DC Inverter Hyper

Page 19: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

SRK 20 ZJX-S SRK 25 ZJX-S SRK 35 ZJX-S SRK 50 ZJX-S SRK 60 ZJX-S

SRC 20 ZJX-S SRC 25 ZJX-S SRC 35 ZJX-S SRC 50 ZIX-S SRC 60 ZIX-S

DC Inverter

2,00 (0,90~3,10) 2,55 (0,90~3,20) 3,50 (0,90~4,10) 5,00 (0,70~6,20) 6,00 (0,80~6,80)

2,50 (0,90~4,30) 3,13 (0,90~4,70) 4,30 (0,90~5,10) 6,00 (0,70~8,80) 6,80 (0,80~9,70)

0,35 (0,19~0,70) 0,49 (0,19~0,82) 0,845 (0,19~1,01) 1,30 (0,20~2,20) 1,86 (0,25~2,30)

0,45 (0,23~1,00) 0,595 (0,23~1,12) 0,96 (0,23~1,35) 1,35 (0,20~2,26) 1,67 (0,25~2,70)

5,71 / A 5,20 / A 4,14 / A 3,85 / A 3,23 / A

5,56 / A 5,26 / A 4,48 / A 4,44 / A 4,07 / A

175 245 423 650 930

1-220~240V-50HZ

O.U.

1,9 - 2,4 2,5 - 3,1 4,0 - 4,6 6,0 - 6,2 8,5 - 7,7

3

6,35 (1/4") - 9,52 (3/8") 6,35 (1/4") - 12,7 (1/2")

15 30

10/10 20/20

1,20 1,40

15

- 20

-15°C~+46°C

-15°C~+21°C

309x890x220

15

39/30/21 41/31/22 43/33/22 45/38/26 47/38/26

31/22/13 33/23/14 35/25/14 37/30/18 39/30/18

690/480/300 750/540/300 810/570/300 810/660/480 870/750/510

16

IR Wireless

590x780(+62)x290 640x800(+71)x290

38 43

47- 39 47- 39 50 - 42 48 - 40 51 - 43

1770 1950 2160 2490

The SRK 50~60 ZJX-S units can also be used in combination with outdoor Conter units in Twin, Triple and Double Twin modes. For more details refer to the pages of the combinations in the Commercial section of this catalogue.

Indoor Unit Model

Outdoor Unit Model

Type

CapacityCooling kW

Heating kW

Power Input Cooling kW

Heating kW

EER

COP

Annual Consumption (cooling) (500h/year) kW

Power supplyPh-V-Hz

I.U.~O.U.

Input Rated Current (Cooling - Heating) A

Wiring cables i.u./o.u. (without ground) n°

Refrigerant Pipe Liquid/Gas side inch.

Max splitting distance indoor/outdoor m

Max splitting level difference (out.-ind./ind.-out.) m

Refrigerant Precharge Kg

MAX Splitting without Refrigerant Precharge m

Additional Refrigerant Charge g/m

Temperature range cooling °C

Temperature range heating °C

Indoor Unit Specifications

Indoor Unit Dimension (HxWxD) mm

Net weight Kg

Indoor Noise level 1 m (Hi/Mi/Lo) dB(A)

Indoor Noise level 2,5 m (Hi/Mi/Lo) dB(A)

Indoor air flow (Hi/Mi/Lo) m3/h

Drain hose diameter mm

Remote Controller (st. equipment) type

Outdoor Unit Specifications

Outdoor UnitDimension (HxWxD) mm

Net weight Kg

Max noise level 1 - 2,5 m dB(A)

Max air flow m3/h

Page 20: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Floor standing air-conditioners, 3 capacities available (2,5~5,0 kW)

Energy Class A, both in cooling and in heating

Long piping length: 30 m (5,0 kW)

Low sound level: 26 dB(A) only (2,5 kW)

Sophisticated and modern design

Console SRF 25~50 ZJX-S

Auto air outlet selectionLower and upper outlets, in cooling and heating, spread comfort air to every corner. In heating operation the automatic adjustment of lower air outlet direction prevents the stirring up of warm air and keeps optimum comfort at floor level.

Superlink II connectionThe units can be connected to RC-E4 wired remote control and to Superlink II system, thanks to the optional interface kit SC-BIKN-E and SC-ADNA-E interface.

SRF 25 ZJX-S / SRC 25 ZJX-SSRF 35 ZJX-S / SRC 35 ZJX-SSRF 50 ZJX-S / SRC 50 ZIX-S

These indoor units can be coupled with the outdoor units

SCM ZJ-S from the Multi System DC Inverter Hyper

Page 21: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

SRF 25 ZJX-S SRF 35 ZJX-S SRF 50 ZJX-S

SRC 25 ZJX-S SRC 35 ZJX-S SRC 50 ZIX-S

DC Inverter

2,50 (0,90~3,20) 3,50 (0,90~4,10) 5,00 (0,70~5,50)

3,40 (0,90~4,70) 4,50 (0,90~5,10) 6,00 (0,70~7,00)

0,521 (0,19~0,82) 0,890 (0,19~1,26) 1,390 (0,20~1,80)

0,723 (0,23~1,20) 1,124 (0,23~1,43) 1,540 (0,20~2,25)

4,80 / A 3,93 / A 3,60 / A

4,70 / A 4,00 / A 3,90 / A

261 445 695

1-220~240V-50HZ

O.U.

2,6 - 3,6 4,1 - 5,2 6,4 - 7,1

3

6,35 (1/4") - 9,52 (3/8") 6,35 (1/4") - 12,7 (1/2")

15 30

10/10 20/20

1,20 1,40

15

- 20

-15°C~+46°C

-15°C~+21°C

600x860x238

18 19

38/31/26 39/33/28 45/38/30

30/23/18 31/25/20 37/30/22

540/456/348 552/468/384 690/576/396

16

IR Wireless

590x780(+62)x290 640x800(+71)x290

38 43

47- 39 50 - 42 48 - 40

1770 1950 2160

Indoor Unit Model

Outdoor Unit Model

Type

CapacityCooling kW

Heating kW

Power Input Cooling kW

Heating kW

EER

COP

Annual Consumption (cooling) (500h/year) kW

Power supplyPh-V-Hz

I.U.~O.U.

Input Rated Current (Cooling - Heating) A

Wiring cables i.u./o.u. (without ground) n°

Refrigerant Pipe Liquid/Gas side inch.

Max splitting distance indoor/outdoor m

Max splitting level difference (out.-ind./ind.-out.) m

Refrigerant Precharge Kg

MAX Splitting without Refrigerant Precharge m

Additional Refrigerant Charge g/m

Temperature range cooling °C

Temperature range heating °C

Indoor Unit Specifications

Indoor Unit Dimension (HxWxD) mm

Net weight Kg

Indoor Noise level 1 m (Hi/Mi/Lo) dB(A)

Indoor Noise level 2,5 m (Hi/Mi/Lo) dB(A)

Indoor air flow (Hi/Mi/Lo) m3/h

Drain hose diameter mm

Remote Controller (st. equipment) type

Outdoor Unit Specifications

Outdoor UnitDimension (HxWxD) mm

Net weight Kg

Max noise level 1 - 2,5 m dB(A)

Max air flow m3/h

Page 22: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Ceiling available in 3 capacities (4,0~5,6 kW)

Energy class A, both in heating and in cooling (4,0 kW)

Extremely high splitting distance: 30 m

Suitable for large spaces due to the powerful airflow

Installation FlexibilityFlexible installation: the refrigerant pipework can be installed in three different positions (on the back, on the top, to the right) as well as the drain pipework (on the left or right).

Operating range, in heating and cooling, with an outdoor temperature as low as -15° C

Ceiling FDEN 40~60VD

Top

Back

RightCompact DesignEasy and fast installation withonly 21 cm height and 28 kg(4,0~5,0 kW) net weight.

FDEN 40VD / SRC 40 ZIX-SFDEN 50VD / SRC 50 ZIX-SFDEN 60VD / SRC 60 ZIX-S

Superlink II connectionThe units can be connected to RC-E4 wired remote control and to Superlink II system, thanks to the optional interface kit SC-BIKN-E and SC-ADNA-E interface.

Page 23: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

FDEN 40VD FDEN 50VD FDEN 60VD

SRC 40 ZIX-S SRC 50 ZIX-S SRC 60 ZIX-S

DC Inverter

4,00 (1,80~4,70) 5,00 (2,20~5,60) 5,60 (2,80~6,30)

4,50 (2,00~5,40) 5,40 (2,50~6,30) 6,70 (3,10~7,10)

1,04 1,59 1,95

1,13 1,58 2,12

3,85 / A 3,14 / B 2,87 / C

3,98 / A 3,42 / B 3,16 / D

520 795 975

1-220~240V-50HZ

O.U.

4,7 - 5,1 7,1 - 7,0 8,7 - 9,4

3

6,35 (1/4") - 12,7 (1/2")

30

20/20

1,40

15

20

-15°C~+43°C

-15°C~+21°C

210x1070x690 210x1320x690

28 37

39/38/37 39/38/37 41/39/38

31/30/29 31/30/29 33/31/30

660/540/420 660/540/420 1080/840/720

20

640x800x290

43

47- 39 47 - 39 48 - 40

2400

Indoor Unit Model

Outdoor Unit Model

Type

CapacityCooling kW

Heating kW

Power Input Cooling kW

Heating kW

EER

COP

Annual Consumption (cooling) (500h/year) kW

Power supplyPh-V-Hz

I.U.~O.U.

Input Rated Current (Cooling - Heating) A

Wiring cables i.u./o.u. (without ground) n°

Refrigerant Pipe Liquid/Gas side inch.

Max splitting distance indoor/outdoor m

Max splitting level difference (out.-ind./ind.-out.) m

Refrigerant Precharge Kg

MAX Splitting without Refrigerant Precharge m

Additional Refrigerant Charge g/m

Temperature range cooling °C

Temperature range heating °C

Indoor Unit Specifications

Indoor Unit Dimension (HxWxD) mm

Net weight Kg

Indoor Noise level 1 m (Hi/Mi/Lo) dB(A)

Indoor Noise level 2,5 m (Hi/Mi/Lo) dB(A)

Indoor air flow (Hi/Mi/Lo) m3/h

Drain hose diameter mm

Remote Controller (st. equipment) type

Outdoor Unit Specifications

Outdoor UnitDimension (HxWxD) mm

Net weight Kg

Max noise level 1 - 2,5 m dB(A)

Max air flow m3/h

Page 24: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

4 way cassette available in 3 capacities (4,0~5,6 kW)

Energy class A, both in heating and in cooling

Wireless Remote Control Kit withRCN-T-36W-E (optional)

Detachable covers at the four corners for easier installation

Extremely high splitting distance: 30 m

Easy checking of condensate drain pan condition

Operating range, in heating and cooling, with an outdoor temperature as low as -15° C

Condensate drain pump included

4-ways Cassette 84x84 FDT 40~60VD

Height reduction from 27 to 24,6 cm.

New design of the air louversAccording to room temperature conditions, 4 directions of air flow can be controlled by individual flap as preferred. As individual flap control is available even after installation, installation area becomes wider than before.

Low Profile designThe new design of the heat exchanger - reduced from 2 components to a single component - results in decrease in the unit height. Moreover, thanks to the application of DC fan motors, FDT units show high energy efficiencies levels, weight reduction and a very compact design.

FDT 40VD / SRC 40 ZIX-SFDT 50VD / SRC 50 ZIX-SFDT 60VD / SRC 60 ZIX-S

Superlink II connectionThe units can be connected to RC-E4 wired remote control and to Superlink II system, thanks to the optional interface kit SC-BIKN-E and SC-ADNA-E interface.

Page 25: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

FDT 40VD FDT 50VD FDT 60VD

SRC 40 ZIX-S SRC 50 ZIX-S SRC 60 ZIX-S

DC Inverter

4,00 (1,80~4,70) 5,00 (2,20~5,60) 5,60 (2,80~6,30)

4,50 (2,00~5,40) 5,40 (2,50~6,30) 6,70 (3,10~7,10)

0,93 1,29 1,57

1,15 1,29 1,85

4,30 / A 3,88 / A 3,57 / A

3,91 / A 4,19 / A 3,62 / A

465 645 785

1-220~240V-50HZ

O.U.

4,1 - 5,2 5,7 - 5,7 7,0 - 8,2

3

6,35 (1/4") - 12,7 (1/2")

30

20/20 20/20 20/20

1,40 1,40 1,40

15

20

-15°C~+43°C

-15°C~+21°C

246x840x840

22

33/31/30 33/31/30 33/31/30

25/23/22 25/23/22 25/23/22

1080/960/840 1080/960/840 1080/960/840

20

640x800x290

43

47- 39 48 - 40

2400

T-PSA-3AW-E

35x950x950

5,5

Indoor Unit Model

Outdoor Unit Model

Type

CapacityCooling kW

Heating kW

Power Input Cooling kW

Heating kW

EER

COP

Annual Consumption (cooling) (500h/year) kW

Power supplyPh-V-Hz

I.U.~O.U.

Input Rated Current (Cooling - Heating) A

Wiring cables i.u./o.u. (without ground) n°

Refrigerant Pipe Liquid/Gas side inch.

Max splitting distance indoor/outdoor m

Max splitting level difference (out.-ind./ind.-out.) m

Refrigerant Precharge Kg

MAX Splitting without Refrigerant Precharge m

Additional Refrigerant Charge g/m

Temperature range cooling °C

Temperature range heating °C

Indoor Unit Specifications

Indoor Unit Dimension (HxWxD) mm

Net weight Kg

Indoor Noise level 1 m (Hi/Mi/Lo) dB(A)

Indoor Noise level 2,5 m (Hi/Mi/Lo) dB(A)

Indoor air flow (Hi/Mi/Lo) m3/h

Drain hose diameter mm

Remote Controller (st. equipment) type

Outdoor Unit Specifications

Outdoor UnitDimension (HxWxD) mm

Net weight Kg

Max noise level 1 - 2,5 m dB(A)

Max air flow m3/h

Accessories

Panel

Dimension (HxWxD) mm

Net weight Kg

Page 26: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

4-ways Cassette 60x60 FDTC 25~60VD

FDTC 25VD / SRC 25 ZJX-SFDTC 35VD / SRC 35 ZJX-SFDTC 40VD / SRC 40 ZIX-SFDTC 50VD / SRC 50 ZIX-SFDTC 60VD / SRC 60 ZIX-S

4 way cassette available in 5 capacities (2,5~5,6 kW)

Energy class A, both in heating and in cooling (2,5~5,0 kW)

Wireless Remote Control Kit withRCN-TC-24W-ER (optional)

Detachable covers at the four corners for easier installation

Extremely high splitting distance: 30 m(4,0~6,0 kW)

Ideal for installation in modular ceilings

Operating range, in heating and cooling, with an outdoor temperature as low as -15° C

Condensate drain pump included

Air flowThe new shape and design of the louver help in redirecting the air flow away from the ceiling, to reduce ceiling stains.

Low Profile designUltra slim design with only 24,8 cm height: ideal for installation in modular ceilings.

Superlink II connectionThe units can be connected toRC-E4 wired remote control and to Superlink II system, thanks to the optional interface SC-ADNA-E interface.

2,5/3,5/5,0 and 5,6 kW I.U. can be coupled with the outdoor units SCM ZJ-S from theMulti

System DC Inverter Hyper

Low noiseReduced noise levels than previous models.

3 dB(A)down

5 dB(A)down

previousmodels

new models(cooling)

new models(heating)

FDTC 40/50/60VD

Page 27: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

FDTC 25VD FDTC 35VD FDTC 40VD FDTC 50VD FDTC 60VD

SRC 25 ZJX-S SRC 35 ZJX-S SRC 40 ZIX-S SRC 50 ZIX-S SRC 60 ZIX-S

DC Inverter

2,55 (0,90~3,90) 3,60 (0,90~4,10) 4,00 (1,80~4,70) 5,00 (2,20~5,60) 5,60 (2,80~6,30)

3,45 (0,90~4,70) 4,25 (0,90~5,10) 4,50 (2,00~5,40) 5,40 (2,50~6,30) 6,70 (3,10~6,70)

0,6 1,07 1,04 1,56 1,99

0,84 1,16 1,10 1,45 2,08

4,25 / A 3,36 / A 3,85 / A 3,21 / A 2,81 / C

4,11 / A 3,66 / A 4,09 / A 3,72 / A 3,22 / C

300 535 520 780 995

1-220~240V-50HZ

O.U.

2,6 - 3,6 4,1 - 5,2 4,6 - 4,9 6,9 - 6,4 8,3 - 8,7

3

6,35 (1/4") - 9,52 (3/8") 6,35 (1/4") - 12,7 (1/2")

15 30

10/10 20/20

1,20 1,40

15

- 20

-15°C~+46°C -15°C~+43°C

-15°C~+21°C

248x570x570

15

36/32/29 40/36/30 42/36/30 42/36/30 46/39/30

28/24/21 32/28/22 34/28/22 34/28/22 38/31/22

540/480/390 570/540/420 690/540/420 690/540/420 810/600/420

20

590x780(+62)x290 640x800x290

38 43

47- 39 50 - 42 47- 39 47 - 39 48 - 40

1770 1950 2400

TC-PSA-25W-E

35x700x700

3,5

Indoor Unit Model

Outdoor Unit Model

Type

CapacityCooling kW

Heating kW

Power Input Cooling kW

Heating kW

EER

COP

Annual Consumption (cooling) (500h/year) kW

Power supplyPh-V-Hz

I.U.~O.U.

Input Rated Current (Cooling - Heating) A

Wiring cables i.u./o.u. (without ground) n°

Refrigerant Pipe Liquid/Gas side inch.

Max splitting distance indoor/outdoor m

Max splitting level difference (out.-ind./ind.-out.) m

Refrigerant Precharge Kg

MAX Splitting without Refrigerant Precharge m

Additional Refrigerant Charge g/m

Temperature range cooling °C

Temperature range heating °C

Indoor Unit Specifications

Indoor Unit Dimension (HxWxD) mm

Net weight Kg

Indoor Noise level 1 m (Hi/Mi/Lo) dB(A)

Indoor Noise level 2,5 m (Hi/Mi/Lo) dB(A)

Indoor air flow (Hi/Mi/Lo) m3/h

Drain hose diameter mm

Remote Controller (st. equipment) type

Outdoor Unit Specifications

Outdoor UnitDimension (HxWxD) mm

Net weight Kg

Max noise level 1 - 2,5 m dB(A)

Max air flow m3/h

Accessories

Panel

Dimension (HxWxD) mm

Net weight Kg

Page 28: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Ducted low SRR 25~35 ZJ-S

Low static pressure duct types, available in 2 capacities (2,5~3,5 kW)

Compact dimensions: 23 cm high only

SRR 25 ZJ-S / SRC 25 ZJX-SSRR 35 ZJ-S / SRC 35 ZJX-S

Accessories (optional)

RDU 12E RTS 12

Drain pump Recovery grille from below

RFJ 22 RBF 12

2-way ducts Recovery filter

Superlink II connectionThe units can be connected to RC-E4 wired remote control and to Superlink II system, thanks to the optional interface kit SC-BIKN-E and SC-ADNA-E interface.

These indoor units can be coupled with the outdoor units

SCM ZJ-S from the Multi System DC Inverter Hyper

Page 29: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

SRR 25 ZJ-S SRR 35 ZJ-S

SRC 25 ZJX-S SRC 35 ZJX-S

DC Inverter

2,50 (0,90~3,20) 3,50 (0,90~4,10)

3,40 (0,90~4,70) 4,20 (0,90~5,10)

0,58 (0,19 ~ 0,82) 1,08 (0,19 ~ 1,26)

0,75 (0,23 ~ 1,20) 1,10 (0,23 ~ 1,43)

4,31 / A 3,24 / A

4,53 / A 3,82 / A

290 540

1-220~240V-50HZ

O.U.

2,9 - 3,7 5,0 - 5,1

3 3

6,35 (1/4") - 9,52 (3/8")

15

10/10

1,20

15

-

-15°C~+46°C

-15°C~+21°C

230x740x455

22

40/35/29 42/37/30

32/27/21 34/29/22

510/420/300 540/450/330

18 20

16

IR Wireless

590x780(+62)x290

38

47- 39 50 - 42

1770 1950

Indoor Unit Model

Outdoor Unit Model

Type

CapacityCooling kW

Heating kW

Power Input Cooling kW

Heating kW

EER

COP

Annual Consumption (cooling) (500h/year) kW

Power supplyPh-V-Hz

I.U.~O.U.

Input Rated Current (Cooling - Heating) A

Wiring cables i.u./o.u. (without ground) n°

Refrigerant Pipe Liquid/Gas side inch.

Max splitting distance indoor/outdoor m

Max splitting level difference (out.-ind./ind.-out.) m

Refrigerant Precharge Kg

MAX Splitting without Refrigerant Precharge m

Additional Refrigerant Charge g/m

Temperature range cooling °C

Temperature range heating °C

Indoor Unit Specifications

Indoor Unit Dimension (HxWxD) mm

Net weight Kg

Indoor Noise level 1 m (Hi/Mi/Lo) dB(A)

Indoor Noise level 2,5 m (Hi/Mi/Lo) dB(A)

Indoor air flow (Hi/Mi/Lo) m3/h

Drain hose diameter mm

Remote Controller (st. equipment) type

Outdoor Unit Specifications

Outdoor UnitDimension (HxWxD) mm

Net weight Kg

Max noise level 1 - 2,5 m dB(A)

Max air flow m3/h

Page 30: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Ducted air-conditioning unit available in 2 capacities (5,0~5,6 kW)

Energy class A, both in heating and in cooling (5,0 kW)

Extremely high splitting distance: 30 m

Ultra-compact design: only 29,9 cm height

Perfect for small/medium rooms

Operating range, in heating and cooling, with an outdoor temperature as low as -15° C

Filter kit (optional) UM-FL1E (FDUM 50VD), UM-FL2E (FDUM 60VD)

Ducted medium FDUM 50~60VD

Drain pump included(60 cm)Included drain pump with 60 cm from the base of the unit allows for greater flexibility in layout and installation.

less than

600 mm

Flexible hose

FDUM 50VD / SRC 50 ZIX-SFDUM 60VD / SRC 60 ZIX-S

Superlink II connectionThe units can be connected to RC-E4 wired remote control and to Superlink II system, thanks to the optional interface kit SC-BIKN-E and SC-ADNA-E interface.

Page 31: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

FDUM 50VD FDUM 60VD

SRC 50 ZIX-S SRC 60 ZIX-S

DC Inverter

5,00 (2,20~5,60) 5,60 (2,80~6,30)

5,40 (2,50~6,30) 6,70 (3,10~7,10)

1,52 1,86

1,41 1,96

3,29 / A 3,01 / B

3,83 / A 3,42 / B

760 930

1-220~240V-50HZ

O.U.

6,7 - 6,3 8,2 - 9,0

3

6,35 (1/4") - 12,7 (1/2")

30

20/20

1,40

15

20

-15°C~+43°C

-15°C~+21°C

299x750x635 299x950x635

34 40

34/31/28 34/31/28

26/23/20 26/23/20

780/720/660 1080/960/840

Standard 50/40 - Max 85/100

20

640x800x290

43

48 - 40

2400

Indoor Unit Model

Outdoor Unit Model

Type

CapacityCooling kW

Heating kW

Power Input Cooling kW

Heating kW

EER

COP

Annual Consumption (cooling) (500h/year) kW

Power supplyPh-V-Hz

I.U.~O.U.

Input Rated Current (Cooling - Heating) A

Wiring cables i.u./o.u. (without ground) n°

Refrigerant Pipe Liquid/Gas side inch.

Max splitting distance indoor/outdoor m

Max splitting level difference (out.-ind./ind.-out.) m

Refrigerant Precharge Kg

MAX Splitting without Refrigerant Precharge m

Additional Refrigerant Charge g/m

Temperature range cooling °C

Temperature range heating °C

Indoor Unit Specifications

Indoor Unit Dimension (HxWxD) mm

Net weight Kg

Indoor Noise level 1 m (Hi/Mi/Lo) dB(A)

Indoor Noise level 2,5 m (Hi/Mi/Lo) dB(A)

Indoor air flow (Hi/Mi/Lo) m3/h

Drain hose diameter mm

Remote Controller (st. equipment) type

Outdoor Unit Specifications

Outdoor UnitDimension (HxWxD) mm

Net weight Kg

Max noise level 1 - 2,5 m dB(A)

Max air flow m3/h

Page 32: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Wall-mounted units, available in 4 capacities (2,0~7,1 kW)

Energy Class A, both in cooling and in heating

Particularly high splitting distance:30 m (7,1 kW)

Low noise level: 21 dB(A) only(2,0~2,5 kW)

Superlink I connectionThe units can be connected to RC-E1R wired remote control and to Superlink I system, thanks to the optional interface SC-AD-ER interface (7,1 kW ).

Antibacterial treatment of the fan blades

Operating range, in heating and cooling, with an outdoor temperature as low as -15° C

Wall-mounted SRK 20~35 ZGX-S, SRK 71 ZE-S1

SRK 20 ZGX-S / SRC 20 ZGX-SSRK 25 ZGX-S / SRC 25 ZGX-SSRK 35 ZGX-S / SRC 35 ZGX-S

SRK 71 ZE-S1/ SRC 71 ZE-S1

Page 33: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

SRK 20 ZGX-S SRK 25 ZGX-S SRK 35 ZGX-S SRK 71 ZE-S1

SRC 20 ZGX-S SRC 25 ZGX-S SRC 35 ZGX-S SRC 71 ZE-S1

DC Inverter

2,00 (0,80~2,80) 2,50 (0,80~3,00) 3,50 (0,80~3,90) 7,10 (0,90~8,00)

2,40 (0,80~4,60) 3,00 (0,80~5,00) 4,20 (0,80~5,10) 8,00 (0,90~10,50)

0,37 (0,23~0,91) 0,50 (0,23~0,64) 0,87 (0,23~0,98) 2,21 (0,32~2,98)

0,44 (0,29~1,27) 0,59 (0,29~1,16) 1,00 (0,29~1,19) 2,21 (0,26~3,75)

5,41 / A 5,00 / A 4,02 / A 3,21 / A

5,45 / A 5,08 / A 4,20 / A 3,62 / A

185 250 435 1105

1-220~240V-50HZ

I.U.

2,1 - 2,5 2,5 - 2,9 4,2 - 4,9 10,10 - 10,10

3

6,35 (1/4") - 9,52 (3/8") 6,35 (1/4") - 15,88 (5/8")

15 30

10/10 20/20

1,20 1,90

15

- 20

-15°C~+46°C

-15°C~+21°C

298x840x259 318x1098x248

12 15

42/34/21 43/34/21 44/35/22 40/34/26

34/26/13 35/26/13 36/27/14 32/26/18

708/-/- 708/-/- 720/-/- 1200/-/-

16

IR Wireless

540x780x290 750x880x340

38 59

44- 36 45- 37 47- 39 52- 44

1800 3360

Indoor Unit Model

Outdoor Unit Model

Type

CapacityCooling kW

Heating kW

Power Input Cooling kW

Heating kW

EER

COP

Annual Consumption (cooling) (500h/year) kW

Power supplyPh-V-Hz

I.U.~O.U.

Input Rated Current (Cooling - Heating) A

Wiring cables i.u./o.u. (without ground) n°

Refrigerant Pipe Liquid/Gas side inch.

Max splitting distance indoor/outdoor m

Max splitting level difference (out.-ind./ind.-out.) m

Refrigerant Precharge Kg

MAX Splitting without Refrigerant Precharge m

Additional Refrigerant Charge g/m

Temperature range cooling °C

Temperature range heating °C

Indoor Unit Specifications

Indoor Unit Dimension (HxWxD) mm

Net weight Kg

Indoor Noise level 1 m (Hi/Mi/Lo) dB(A)

Indoor Noise level 2,5 m (Hi/Mi/Lo) dB(A)

Indoor air flow (Hi/Mi/Lo) m3/h

Drain hose diameter mm

Remote Controller (st. equipment) type

Outdoor Unit Specifications

Outdoor UnitDimension (HxWxD) mm

Net weight Kg

Max noise level 1 - 2,5 m dB(A)

Max air flow m3/h

Page 34: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Wall-mounted units, available in 4 capacities (2,0~5,0 kW)

Energy Class A, both in cooling and in heating

Particularly high splitting distance:25 m (5,0 kW)

Low noise level: 21 dB(A) only(2,0~2,5 kW)

Antibacterial treatment of the fan blades

Sophisticated and modern design

Operating range, in heating and cooling, with an outdoor temperature as low as -15° C

Wall-mounted SRK 20~50 ZJ-S

SRK 20 ZJ-S / SRC 20 ZJ-SSRK 25 ZJ-S / SRC 25 ZJ-S SRK 35 ZJ-S / SRC 35 ZJ-S SRK 50 ZJ-S / SRC 50 ZJ-S

Superlink II connectionThe units can be connected to RC-E4 wired remote control and to Superlink II system, thanks to the optional interface kit SC-BIKN-E and SC-ADNA-E interface.

These indoor units can be coupled with the outdoor units

SCM ZJ-S from the Multi System DC Inverter Hyper

Page 35: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

SRK 20 ZJ-S SRK 25 ZJ-S SRK 35 ZJ-S SRK 50 ZJ-S

SRC 20 ZJ-S SRC 25 ZJ-S SRC 35 ZJ-S SRC 50 ZJ-S

DC Inverter

2,00 (1,00~2,70) 2,50 (1,00~2,90) 3,50 (1,00~3,80) 5,00 (1,60~5,50)

2,70 (1,20~3,90) 3,20 (1,20~4,20) 4,00 (1,30~4,80) 5,80 (1,60~6,60)

0,44 (0,21~0,77) 0,62 (0,21~0,88) 1,01 (0,21~1,24) 1,55 (0,40~2,20)

0,62 (0,27~1,38) 0,80 (0,27~1,36) 1,00 (0,29~1,45) 1,59 (0,42~2,10)

4,55 / A 4,03 / A 3,47 / A 3,23 / A

4,35 / A 4,00 / A 4,00 / A 3,65 / A

220 310 500 775

1-220~240V-50HZ

I.U.

2,5 - 3,2 3,2 - 4,0 4,9 - 4,9 7,1 - 7,3

3

6,35 (1/4") - 9,52 (3/8") 6,35 (1/4") - 12,7 (1/2")

15 25

10/10 15/15

0,75 0,75 1,05 1,35

15

- 20

-15°C~+46°C

-15°C~+21°C

294x798x229

9,5

33/27/21 34/28/21 42/32/22 46/37/26

25/19/13 26/20/13 34/24/14 38/29/18

468/336/288 474/360/300 606/384/300 810/660/480

16

IR Wireless

540x780(+62)x290 640x800(+71)x290

32 35 42

47- 39 48- 40 50 - 42 48 - 40

1770 1926 1890 2160

Indoor Unit Model

Outdoor Unit Model

Type

CapacityCooling kW

Heating kW

Power Input Cooling kW

Heating kW

EER

COP

Annual Consumption (cooling) (500h/year) kW

Power supplyPh-V-Hz

I.U.~O.U.

Input Rated Current (Cooling - Heating) A

Wiring cables i.u./o.u. (without ground) n°

Refrigerant Pipe Liquid/Gas side inch.

Max splitting distance indoor/outdoor m

Max splitting level difference (out.-ind./ind.-out.) m

Refrigerant Precharge Kg

MAX Splitting without Refrigerant Precharge m

Additional Refrigerant Charge g/m

Temperature range cooling °C

Temperature range heating °C

Indoor Unit Specifications

Indoor Unit Dimension (HxWxD) mm

Net weight Kg

Indoor Noise level 1 m (Hi/Mi/Lo) dB(A)

Indoor Noise level 2,5 m (Hi/Mi/Lo) dB(A)

Indoor air flow (Hi/Mi/Lo) m3/h

Drain hose diameter mm

Remote Controller (st. equipment) type

Outdoor Unit Specifications

Outdoor UnitDimension (HxWxD) mm

Net weight Kg

Max noise level 1 - 2,5 m dB(A)

Max air flow m3/h

Page 36: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Wall-mounted units, available in 4 capacities (2,0~5,0 kW)

Energy Class A, both in cooling and in heating (2,0~3,5 kW)

Particularly high splitting distance:25 m (5,0 kW)

Low noise level: 21 dB(A) only (2,0 kW )

Antibacterial treatment of the fan blades

Operating range, in heating and cooling, with an outdoor temperature as low as -15° C

Ultra slim model: 19,9 cm deep only

Wall-mounted SRK 20~50 ZG-S

Superlink I connectionThe units can be connected to RC-E1R wired remote control and to Superlink II system, thanks to the optional interface kit SC-BIK1-E and SC-AD-ER interface.

SRK 20 ZG-S / SRC 20 ZG-SSRK 25 ZG-S / SRC 25 ZG-SSRK 35 ZG-S / SRC 35 ZG-SSRK 50 ZG-S / SRC 50 ZG-S

Page 37: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

SRK 20 ZG-S SRK 25 ZG-S SRK 35 ZG-S SRK 50 ZG-S

SRC 20 ZG-S SRC 25 ZG-S SRC 35 ZG-S SRC 50 ZG-S

DC Inverter

2,00 (0,70~2,80) 2,50 (0,70~3,00) 3,50 (0,70~3,90) 5,00 (0,70~5,30)

2,70 (0,70~4,60) 3,40 (0,70~4,80) 4,20 (0,70~5,10) 5,80 (0,70~7,90)

0,44 (0,21~0,91) 0,62 (0,21~0,97) 1,05 (0,21~1,22) 1,66 (0,22~2,10)

0,62 (0,21~1,27) 0,93 (0,21~1,30) 1,14 (0,21~1,32) 1,70 (0,11~2,71)

4,55 / A 4,03 / A 3,33 / A 3,01 / B

4,35 / A 3,66 / A 3,68 / A 3,41 / B

220 310 525 830

1-220~240V-50HZ

I.U.

2,4 - 3,0 3,1 - 4,5 4,9 - 5,3 7,6 - 7,9

3

6,35 (1/4") - 9,52 (3/8") 6,35 (1/4") - 12,7 (1/2")

15 25

10/10 15/15

0,90 1,10 1,35

15

- 20

-15°C~+46°C

-15°C~+21°C

268x790x199

8,5

35/29/21 36/30/22 40/32/23 47/42/26

27/21/13 28/22/14 32/24/15 39/34/18

444/-/- 456/-/- 510/-/- 690/-/-

16

IR Wireless

540x780x290 640x850x290

35 38 43

44- 36 48 - 40 48 - 40

1800 2520

Indoor Unit Model

Outdoor Unit Model

Type

CapacityCooling kW

Heating kW

Power Input Cooling kW

Heating kW

EER

COP

Annual Consumption (cooling) (500h/year) kW

Power supplyPh-V-Hz

I.U.~O.U.

Input Rated Current (Cooling - Heating) A

Wiring cables i.u./o.u. (without ground) n°

Refrigerant Pipe Liquid/Gas side inch.

Max splitting distance indoor/outdoor m

Max splitting level difference (out.-ind./ind.-out.) m

Refrigerant Precharge Kg

MAX Splitting without Refrigerant Precharge m

Additional Refrigerant Charge g/m

Temperature range cooling °C

Temperature range heating °C

Indoor Unit Specifications

Indoor Unit Dimension (HxWxD) mm

Net weight Kg

Indoor Noise level 1 m (Hi/Mi/Lo) dB(A)

Indoor Noise level 2,5 m (Hi/Mi/Lo) dB(A)

Indoor air flow (Hi/Mi/Lo) m3/h

Drain hose diameter mm

Remote Controller (st. equipment) type

Outdoor Unit Specifications

Outdoor UnitDimension (HxWxD) mm

Net weight Kg

Max noise level 1 - 2,5 m dB(A)

Max air flow m3/h

Page 38: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Wall-mounted units, available in 3 capacities (2,07~3,6 kW)

Energy class A in heating and cooling(2,07~2,6 kW)

Operating range, in heating and cooling, with an outdoor temperature as low as -5° C

Extremely high splitting distance: 15 m

Wall-mounted SRK 20~40 HG-S

SRK 20 HG-S / SRC 20 HG-SSRK 28 HG-S / SRC 28 HG-SSRK 40 HG-S / SRC 40 HG-S

Page 39: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

SRK 20 HG-S SRK 28 HG-S SRK 40 HG-S

SRC 20 HG-S SRC 28 HG-S SRC 40 HG-S

Constant speed

2,07 2,60 3,60

2,22 2,80 3,92

0,64 0,81 1,12

0,61 0,77 1,15

3,23 / A 3,21 / A 3,21 / A

3,64 / A 3,64 / A 3,41 / B

320 405 560

1-220~240V-50HZ

I.U.

3,1 - 3,0 3,8 - 3,7 5,3 - 5,4

3

6,35 (1/4") - 9,52 (3/8") 6,35 (1/4") - 12,7 (1/2")

15

10/10

0,95 0,85 1,15

15

-

+21°C~+43°C

-5°C~+21°C

268x790x199

8,5

34/30/27 39/33/30 40/38/34

26/22/19 31/25/22 32/30/26

450/-/- 510/-/- 540/-/-

16

IR Wireless

540x780x290

29 31 38

46- 38 46- 38 49 - 41

1620 1740 1920

Indoor Unit Model

Outdoor Unit Model

Type

CapacityCooling kW

Heating kW

Power Input Cooling kW

Heating kW

EER

COP

Annual Consumption (cooling) (500h/year) kW

Power supplyPh-V-Hz

I.U.~O.U.

Input Rated Current (Cooling - Heating) A

Wiring cables i.u./o.u. (without ground) n°

Refrigerant Pipe Liquid/Gas side inch.

Max splitting distance indoor/outdoor m

Max splitting level difference (out.-ind./ind.-out.) m

Refrigerant Precharge Kg

MAX Splitting without Refrigerant Precharge m

Additional Refrigerant Charge g/m

Temperature range cooling °C

Temperature range heating °C

Indoor Unit Specifications

Indoor Unit Dimension (HxWxD) mm

Net weight Kg

Indoor Noise level 1 m (Hi/Mi/Lo) dB(A)

Indoor Noise level 2,5 m (Hi/Mi/Lo) dB(A)

Indoor air flow (Hi/Mi/Lo) m3/h

Drain hose diameter mm

Remote Controller (st. equipment) type

Outdoor Unit Specifications

Outdoor UnitDimension (HxWxD) mm

Net weight Kg

Max noise level 1 - 2,5 m dB(A)

Max air flow m3/h

Page 40: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Wall mounted air-conditioners, 5 capacities available (2,0~6,0 kW)

Energy Class A, both in cooling and in heating

Low sound level: 21 dB(A) only (2,0 kW)

Antibacterial treatment of the blower fan

Sophisticated and modern design

Superlink II connectionThe units can be connected to RC-E4 wired remote control and to Superlink II system, thanks to the optional interface kit SC-BIKN-E and SC-ADAN-E interface.

Operation range in heating and cooling at an outdoor temperature as low as -15° C

Model SRK 20 ZJX-S SRK 25 ZJX-S SRK 35 ZJX-S SRK 50 ZJX-S SRK 60 ZJX-S

Type DC Inverter

CapacityCooling kW 2,00 2,55 3,50 5,00 6,00

Heating kW 2,50 3,13 4,30 6,00 6,80

Power supplyPh-V-Hz 1-220~230V-50HZ

I.U. ~ O.U. O.U.

Wiring cables i.u./o.u. (without ground) n° 3

Refrigerant Pipe Liquid/Gas side mm (inch.) 6,35 (1/4") - 9,52 (3/8") 6,35 (1/4") - 12,7 (1/2")

Indoor Unit Specifications

Indoor unitDimension (HxWxD) mm 309x890x220

Net weight Kg 15

Indoor Noise level 1 m (Hi/Mi/Lo) dB(A) 39/30/21 41/31/22 43/33/22 45/38/26 47/38/26

Indoor Noise level 2,5 m (Hi/Mi/Lo) dB(A) 31/22/13 33/23/14 35/25/14 37/30/18 39/30/18

Indoor air flow (Hi/Mi/Lo) m3/h 690/480/300 750/540/300 810/570/300 810/660/480 870/750/510

Drain hose diameter mm 16

Remote Controller (st. equipment) Type IR Wireless

Optional parts

Wired remote control RC-E4

Indoor units of the Ultra DC Inverter Flex monosplit line

Wall-mounted SRK 20~60 ZJX-S

Page 41: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Floor standing air-conditioners, 3 capacitiesavailable (2,5~5,0 kW)

Energy Class A, both in cooling and in heating

Low sound level: 26 dB(A) only (2,5 kW)

Sophisticated and modern design

Superlink II connectionThe units can be connected to RC-E4 wired remote control and to Superlink II system, thanks to the optional interface kit SC-BIKN-E and SC-ADAN-E interface.

SRF 25 ZJX-S SRF 35 ZJX-S SRF 50 ZJX-S

DC Inverter

2,50 3,50 5,00

3,40 4,50 6,00

1-220~230V-50HZ

O.U.

3

6,35 (1/4") - 9,52 (3/8") 6,35 (1/4") - 12,7 (1/2")

600x860x238

18 19

40/32/26 41/34/28 47/39/30

32/24/18 33/26/20 39/31/22

540/456/348 552/468/384 690/576/396

16

IR Wireless

RC-E4

Indoor units of the Ultra DC Inverter Flex monosplit line

Auto air outlet selectionLower and upper outlets, in cooling and heating, spread comfort air to every corner. In heating operation the automatic adjustment of lower air outlet direction prevents the stirring up of warm air and keeps optimum comfort at floor level.

Console SRF 25~50 ZJX-S

Model

Type

CapacityCooling kW

Heating kW

Power supplyPh-V-Hz

I.U. ~ O.U.

Wiring cables i.u./o.u. (without ground) n°

Refrigerant Pipe Liquid/Gas side mm (inch.)

Indoor Unit Specifications

Indoor unitDimension (HxWxD) mm

Net weight Kg

Indoor Noise level 1 m (Hi/Mi/Lo) dB(A)

Indoor Noise level 2,5 m (Hi/Mi/Lo) dB(A)

Indoor air flow (Hi/Mi/Lo) m3/h

Drain hose diameter mm

Remote Controller (st. equipment) Type

Optional parts

Wired remote control

Page 42: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Condensate drain pump included

Low noise, ref. p. 24

FDTC 25VD FDTC 35VD FDTC 50VD FDTC 60VD

DC Inverter

2,55 3,60 5,00 5,60

3,45 4,25 5,40 6,70

1-220~230V-50HZ

O.U.

3

6,35 (1/4") - 9,52 (3/8") 6,35 (1/4") - 12,7 (1/2")

248x570x570

15

36/32/29 40/36/30 42/36/30 46/39/30

28/24/21 32/28/22 34/28/22 38/31/22

540/480/390 570/540/420 690/540/420 810/600/420

20

-

TC-PSA-25W-E

35x700x700

3,5

RCH-E3

4 way cassette available in 4 capacities (2,5~5,6 kW)

Energy class A, both in heating and in cooling (2,5~5,0 kW)

Wireless Remote Control Kit with RCN-TC-24W-ER (optional)

Detachable covers at the four corners for easier installation

Ideal for installation in modular ceilings

Operating range, in heating and cooling, with an outdoor temperature as low as -15° C

4-ways Cassette 60x60 FDTC 25~60VD

Superlink II connectionThe units can be connected to RC-E4 wired remote control and to Superlink II system, thanks to the optional interface kit SC-BIKN-E and SC-ADAN-E interface.

Indoor units of the Ultra DC Inverter Flex monosplit line

Model

Type

CapacityCooling kW

Heating kW

Power supplyPh-V-Hz

I.U. ~ O.U.

Wiring cables i.u./o.u. (without ground) n°

Refrigerant Pipe Liquid/Gas side mm (inch.)

Indoor Unit Specifications

Indoor unitDimension (HxWxD) mm

Net weight Kg

Indoor Noise level 1 m (Hi/Mi/Lo) dB(A)

Indoor Noise level 2,5 m (Hi/Mi/Lo) dB(A)

Indoor air flow (Hi/Mi/Lo) m3/h

Drain hose diameter mm

Remote Controller (st. equipment) Type

Accessories

Panel

Panel dataDimension (HxWxD) mm

Net weight kg

Optional parts

Wired remote control

Page 43: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Low/medium static pressure duct types, available in 4 capacities (2,5~6,0 kW)

Compact dimensions: 23 cm high only

Superlink II connectionThe units can be connected to RC-E4 wired remote control and to Superlink II system, thanks to the optional interface kit SC-BIKN-E and SC-ADAN-E interface.

SRR 25 ZJ-S SRR 35 ZJ-S SRR 50 ZJ-S SRR 60 ZJ-S

DC Inverter

2,50 3,50 5,00 6,00

3,40 4,20 5,80 6,80

1-220~230V-50HZ

O.U.

3

6,35 (1/4") - 9,52 (3/8") 6,35 (1/4") - 12,7 (1/2")

230x740x455

22 23

40/35/29 42/37/30 48/42/33 51/44/35

32/27/21 34/29/22 40/34/25 43/36/27

510/420/300 540/450/330 630/480/300 750/540/330

18 20 30 45

16

IR Wireless

RC-E4

The 2,5 and 3,5 kW units belong to the Ultra DC Inverter Flex monosplit line

4-ways Cassette 60x60 FDTC 25~60VD Ducted medium and low SRR 25~60 ZJ-S

Model

Type

CapacityCooling kW

Heating kW

Power supplyPh-V-Hz

I.U. ~ O.U.

Wiring cables i.u./o.u. (without ground) n°

Refrigerant Pipe Liquid/Gas side mm (inch.)

Indoor Unit Specifications

Indoor unitDimension (HxWxD) mm

Net weight Kg

Indoor Noise level 1 m (Hi/Mi/Lo) dB(A)

Indoor Noise level 2,5 m (Hi/Mi/Lo) dB(A)

Indoor air flow (Hi/Mi/Lo) m3/h

Available Static Pressure Pa

Drain hose diameter mm

Remote Controller (st. equipment) Type

Optional parts

Wired remote control

Accessories (optional)

RDU 12E RTS 12

Drain pump Recovery grille from below

RFJ 22 RBF 12

2-way ducts Recovery filter

25 and 35 U.I. of the Ultra DC Inverter Flex monosplit line

Page 44: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

SRK 20 ZJ-S SRK 25 ZJ-S SRK 35 ZJ-S SRK 50 ZJ-S

DC Inverter

2,00 2,50 3,50 5,00

2,70 3,20 4,00 5,80

1-220~230V-50HZ

O.U.

3

6,35 (1/4") - 9,52 (3/8") 6,35 (1/4") - 12,7 (1/2")

294x798x229

9,5

33/27/21 34/28/21 42/32/22 46/37/26

25/19/13 26/20/13 34/24/14 38/29/18

468/336/288 474/360/300 606/384/300 678/468/318

16

IR Wireless

RC-E4

Wall-mounted units, available in 4 capacities(2,0~5,0 kW)

Energy Class A, both in cooling and in heating

Low noise level: 21 dB(A) only (2,0~2,5 kW)

Antibacterial treatment of the fan blades

Sophisticated and modern design

Operating range, in heating and cooling, with an outdoor temperature as low as -15° C

Superlink II connectionThe units can be connected to RC-E4 wired remote control and to Superlink II system, thanks to the optional interface kit SC-BIKN-E and SC-ADNA-E interface.

Indoor units of the Plus DC Inverter monosplit line

Wall-mounted SRK 20~50 ZJ-S

Model

Type

CapacityCooling kW

Heating kW

Power supplyPh-V-Hz

I.U. ~ O.U.

Wiring cables i.u./o.u. (without ground) n°

Refrigerant Pipe Liquid/Gas side mm (inch.)

Indoor Unit Specifications

Indoor unitDimension (HxWxD) mm

Net weight Kg

Indoor Noise level 1 m (Hi/Mi/Lo) dB(A)

Indoor Noise level 2,5 m (Hi/Mi/Lo) dB(A)

Indoor air flow (Hi/Mi/Lo) m3/h

Drain hose diameter mm

Remote Controller (st. equipment) Type

Optional parts

Wired remote control

Page 45: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Outdoor units SCM 40~80 ZJ-S

Pipes connections SCM 40 ZJ-S SCM 45 ZJ-S SCM 50 ZJ-S SCM 60 ZJ-S SCM 71 ZJ-S SCM 80 ZJ-S

Length for one indoor unit 25 m 25 m 25 m 25 m 25 m 25 m

Total length for all rooms 30 m 30 m 40 m 40 m 70 m 70 m

level difference

Lowest outdoor unit’s installation point 15 m 15 m 15 m 15 m 20 m 20 m

Highest outdoor unit’s installation point 15 m 15 m 15 m 15 m 20 m 20 m

Max. height difference among indoor units 25 m 25 m 25 m 25 m 25 m 25 m

Refrigerant pipes’ length without additional charge 30 m 20 m 40 m 30 m 40 m 40 m

Outdoor units available in 2 models and 6 different capacities (4,0~8,0 kW)

Low noise level: 25 dB(A) (4,0~4,5 kW)

Operating range, in heating and cooling, with an outdoor temperature as low as -15° C

Model SCM 40 ZJ-S SCM 45 ZJ-S SCM 50 ZJ-S SCM 60 ZJ-S SCM 71 ZJ-S SCM 80 ZJ-S

Type DC Inverter

MAX N° of Indoor Unit n° 2 3 4

CapacityCooling kW 4,00 (1,80~5,90) 4,50 (1,80~6,40) 5,00 (1,80~7,10) 6,00 (1,80~7,50) 7,10 (1,80~8,80) 8,00 (1,80~9,20)

Heating kW 4,50 (1,40~6,90) 5,60 (1,40~7,40) 6,00 (1,40~7,50) 6,80 (1,50~7,80) 8,60 (1,50~9,40) 9,30 (1,50~9,80)

Power Input Cooling kW 0,84 (0,49~1,90) 1,04 (0,49~2,14) 1,08 (0,50~2,15) 1,43 (0,50~2,39) 1,74 (0,00~0,00) 2,16 (0,48~2,83)

Heating kW 0,9 (0,47~2,30) 1,20 (0,47~2,57) 1,31 (0,48~2,58) 1,51 (0,60~3,00) 2,00 (0,00~0,00) 2,26 (0,60~3,43)

Power supplyPh-V-Hz 1-220~230V-50HZ

I.U.~O.U. O.U.

Running current (cool./heat.) A 4,5 - 5,3 5,5 - 6,2 5,5 - 6,3 6,8 - 7,1 00,0 - 00,0 9,90 - 10,4

Wiring cables i.u./o.u. (without ground) n° 3 + 3 3 + 3 + 3 3 + 3 + 3 + 3

Refrigerant Pipe Liquid/Gas side mm (inch.) 2x6,35 (1/4") 2x9,52 (3/8") 3x6,35 (1/4") 3x9,52 (3/8") 4x6,35 (1/4")

4x9,52 (3/8")

Total Piping Length m 30 40 70

Max splitting level difference (out.-ind./ind.-out.) m 15/15 20/20

Refrigerant Precharge Kg 1,4 1,6 1,95 2,5 2,2 3,15

MAX Splitting without Refrigerant Precharge m 30 20 40

Additional Refrigerant Charge Liquid Pipe ø1/4’ g/m - 20 - 20

Temperature range cooling °C -15°C ~ +43°C

Temperature range heating °C -15°C ~ +24°C

Specifications

Outdoor UnitDimension (HxWxD) mm 640x850(+65)x290 750x880(+73)x340

Net weight Kg 47 46 48 49 62

Max noise level 1 - 2,5 m dB(A) 47 - 39 49 - 41 50 - 42 52-44 54 - 46

Max air flow m3/h 2400 2520 3360

The combination tables can be downloaded from the website or obtained on request from sales staff.

Page 46: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Wall-mounted units, available in 8 capacities(2,0~7,1 kW)

Operating range, in heating and cooling, with an outdoor temperature as low as -15° C

Superlink I connectionThe units can be connected to RC-E1R wired remote control and to Superlink I system, thanks to the optional interface kit SC-BIK1-E (only for SKM 20~50 ZG-S) and SC-AD-ER interface.

Wall-mounted SKM 20~71 ZG-S

Model SKM 20 ZG-S SKM 25 ZG-S SKM 28 ZG-S SKM 35 ZG-S SKM 50 ZG-S SKM 60 ZG-S SKM 71 ZG-S

Type DC Inverter

CapacityCooling kW 2,00 2,50 2,80 3,50 5,00 6,00 7,10

Heating kW 3,00 3,40 4,00 4,50 5,80 6,80 8,00

Power supplyPh-V-Hz 1-220~230V-50HZ

I.U.~O.U. O.U.

Wiring cables i.u./o.u. (without ground) n° 3

Refrigerant Pipe Liquid/Gas side mm (inch.) 6,35 (1/4") - 9,52 (3/8") 6,35 (1/4") - 12,7 (1/2")

Indoor Unit Specifications

Indoor unitDimension (HxWxD) mm 268x790x199 318x1098x248

Peso netto Kg 8,5 15

Indoor Noise level 1 m (Hi/Mi/Lo) dB(A) 35/29/23 36/30/24 38/31/24 39/32/25 45/36/25 43/36/26 44/34/26

Indoor Noise level 2,5 m (Hi/Mi/Lo) dB(A) 27/21/15 28/22/16 30/23/16 31/24/17 37/28/17 35/28/18 36/26/18

Indoor air flow (Hi/Mi/Lo) m3/h 450/-/- 468/-/- 498/-/- 528/-/- 678/-/- 1080/-/- 1140/-/-

Drain hose diameter mm 16

Remote Controller (st. equipment) Type IR Wireless

Optional parts

Wired remote control RC-E1R

Page 47: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

STM 25 ZF-S STM 35 ZF-S STM 50 ZF-S STM 60 ZF-S

DC Inverter

2,50 3,50 5,00 6,00

3,40 4,50 5,80 6,80

1-220~230V-50HZ

O.U.

3

6,35 (1/4") - 9,52 (3/8") 6,35 (1/4") - 12,7 (1/2")

248x570x570

14 14,5

35/33/31 38/35/33 40/38/35 47/43/39

27/25/23 30/27/25 32/30/27 39/35/31

480/420/360 540/480/420 600/540/480 780/690/600

25

IR Wireless

TTP42-W-E

35x700x700

3,5

RC-E1R

Superlink I connectionThe units can be connected to RC-E1R wired remote control and to Superlink I system, thanks to the optional SC-AD-ER interface.

4-way Cassette units, for modular ceilings, available in 4 capacities (2,5~6,0 kW)

Drain pump up to 60 cm from lower indoor unit’s profile

Model

Type

CapacityCooling kW

Heating kW

Power supplyPh-V-Hz

I.U. ~ O.U.

Wiring cables i.u./o.u. (without ground) n°

Refrigerant Pipe Liquid/Gas side mm (inch.)

Indoor Unit Specifications

Indoor unitDimension (HxWxD) mm

Net weight Kg

Indoor Noise level 1 m (Hi/Mi/Lo) dB(A)

Indoor Noise level 2,5 m (Hi/Mi/Lo) dB(A)

Indoor air flow (Hi/Mi/Lo) m3/h

Drain hose diameter mm

Remote Controller (st. equipment) Type

Accessories

Panel

Panel dataDimension (HxWxD) mm

Net weight kg

Optional parts

Wired remote control

4-ways Cassette 60x60 STM 25~60 ZF-S

Page 48: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

46

Ducted medium and low

SRRM 25 ZF-S SRRM 35 ZF-S SRRM 50 ZF-S SRRM 60 ZF-S

DC Inverter

2,50 3,50 5,00 6,00

3,40 4,50 5,80 6,80

1-220~230V-50HZ 1-220~230V-50HZ 1-220~230V-50HZ 1-220~230V-50HZ

O.U.

3

6,35 (1/4") - 9,52 (3/8") 6,35 (1/4") - 12,7 (1/2")

230x740x455

22 23

38/32/25 40/35/28 46/40/31 49/42/33

30/24/17 32/27/20 38/32/23 41/34/25

510/390/300 540/450/360 630/540/390 750/600/420

18 20 30 45

16

IR Wireless

RC-E1R

Low/medium static pressure types, available in 4capacities (2,5~6,0 kW)

Compact dimensions: 23 cm high only

Superlink I connectionThe units can be connected to RC-E1R wired remote control and to Superlink I system, thanks to the optional SC-AD-ER interface.

SRRM 25~60 ZF-S

Model

Type

CapacityCooling kW

Heating kW

Power supplyPh-V-Hz

I.U. ~ O.U.

Wiring cables i.u./o.u. (without ground) n°

Refrigerant Pipe Liquid/Gas side mm (inch.)

Indoor Unit Specifications

Indoor unitDimension (HxWxD) mm

Net weight Kg

Indoor Noise level 1 m (Hi/Mi/Lo) dB(A)

Indoor Noise level 2,5 m (Hi/Mi/Lo) dB(A)

Indoor air flow (Hi/Mi/Lo) m3/h

Available Static Pressure Pa

Drain hose diameter mm

Remote Controller (st. equipment) Type

Optional parts

Wired remote control

Accessories (optional)

RDU 12E RTS 12

Drain pump Recovery grille from below

RFJ 22 RBF 12

2-way ducts Recovery filter

Page 49: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Pipes connections SCM 40 ZG-S SCM 45 ZG-S SCM 48 ZG-S SCM 60 ZG-S SCM 80 ZG-S

Length for one indoor unit 25 m 25 m 25 m 25 m 25 m

Total length for all rooms 30 m 30 m 40 m 40 m 70 m

level difference

Lowest outdoor unit’s installation point 15 m 15 m 15 m 15 m 20 m

Highest outdoor unit’s installation point 15 m 15 m 15 m 15 m 20 m

Max. height difference among indoor units 25 m 25 m 25 m 25 m 25 m

Refrigerant pipes’ length without additional charge 30 m 20 m 40 m 30 m 40 m

SCM 40~60 ZG-S

SCM 80 ZG-S

Outdoor units available in 2 models and 5 different capacities (4,0~8,0 kW)

Low noise level: 45 dB(A) (4,0~4,5 kW)

Operating range, in heating and cooling, with an outdoor temperature as low as -15° C

Model SCM 40 ZG-S SCM 45 ZG-S SCM 48 ZG-S SCM 60 ZG-S SCM 80 ZG-S

Type DC Inverter

MAX N° of Indoor Unit n° 2 3 4

CapacityCooling kW 4,00 (1,90~5,00) 4,50 (1,00~6,40) 4,80 (1,10~6,90) 6,00 (1,10~7,50) 8,00 (1,80~9,50)

Heating kW 5,00 (2,20~5,20) 5,60 (1,80~6,80) 6,00 (1,40~7,10) 7,00 (1,40~7,60) 9,30 (0,80~9,60)

Power Input Cooling kW 0,97 (0,47~1,43) 1,19 (0,19~2,22) 1,19 (0,20~2,35) 1,62 (0,40~3,05) 2,22 (0,31~3,00)

Heating kW 1,15 (0,40~1,41) 1,35 (0,22~1,94) 1,38 (0,18~2,03) 1,74 (0,39~2,62) 2,43 (0,21~3,43)

Power supplyPh-V-Hz 1-220~230V-50HZ

I.U.~O.U. O.U.

Running current (cool./heat.) A 4,5 - 5,3 5,5 - 6,2 5,5 - 6,3 7,4 - 8,0 10,2 - 11,2

Wiring cables i.u./o.u. (without ground) n° 3 + 3 3 + 3 + 3 3 + 3 + 3 + 3

Refrigerant Pipe Liquid/Gas side mm (inch.) 2x6,35 (1/4") 2x9,52 (3/8") 3x6,35 (1/4") 3x9,52 (3/8") 4x6,35 (1/4")4x9,52 (3/8")

Total Piping Length m 30 40 70

Max splitting level difference (out.-ind./ind.-out.) m 15/15 20/20

Refrigerant Precharge Kg 1,4 1,6 1,95 2,2 3,15

MAX Splitting without Refrigerant Precharge m 30 20 40 30 40

Additional Refrigerant Charge Liquid Pipe ø1/4’ g/m - 20 - 20

Temperature range cooling °C -15°C ~ +43°C

Temperature range heating °C -15°C ~ +24°C

Specifications

Outdoor UnitDimension (HxWxD) mm 640x850x290 750x880x340

Net weight Kg 44 46 51 66

Max noise level 1 - 2,5 m dB(A) 45 - 37 48 - 40 51 - 43

Max air flow m3/h 2400 2520 3300

Outdoor units SCM 40~80 ZG-S

The combination tables can be downloaded from the website or obtained on request from sales staff.

Page 50: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

HYDROLUTION air-water heat pumps

Hydrolution is the air-water heat pump designed by Mitsubishi Heavy Industries, Ltd. for residential applications.

A complete, modern system that can guarantee warmt, cooling and the production of running hot water, with reduced energy costs and environmentally friendly due to low emissions of carbon dioxide.Hydrolution uses natural energy: the

FDCW 71VNXFDCW 100VNX

HM270V

• high energy performance • low operating costs • easy installation• 1 single internal unit for one year round comfort• Heating- running hot water- cooling

FDCW unit extracts heat from outside air and conveys it inside the home to be air-conditioned. The transition of natural energy to the indoor unit occurs through the coolant circulating in a closed system of refrigeration pipes. The HM270V indoor unit heats the water that circulates, respectively: in the radiators, fan coils and in the underfloor heating systems; at the same time it constitutes a reservoir

of water which, thanks to the help of a heat exchanger built into the unit, ensures the production of hot running water.

Page 51: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Refrigerant

Hot water circuit for heating

Domestic hot water circuit

Underfloor heating system

Outdoor unit

Underfloor Heati

ng

Fan coil unit or radiator

Heating - Hot Water - CoolingThe Hydrolution air-water heat pump collects solar energy from the outside air even below zero degrees, down to -20° C. The speed of the compressor is adjusted according to consumer demand, so that there is no wasted energy expenditure: the COP value of 3.70, in heating mode, is the highest on the market. The implementation of the electrical and refrigeration connections is extremely easy thanks to the structure of the indoor unit.

The system consists of:• FDCW outdoor unit• Refrigerant circuit between FDCW outdoor unit, indoor unit fan

coil and HM270V indoor unit • Connection of the HM270V indoor unit to the primary hot water

producing hydraulic circuit

The HM270V units can be fully integrated in an air conditioning system which also includes the insertion of:

• Solar panels • Oil boiler • Wood pellet stove

Solar panels

Outdoor unit

Outdoor unit HM270V

Heat exchanger and water reservoir (HM270V)

Page 52: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Commercial Range Conter

Commercial Range Conter of Mitsubishi Heavy Industries introduces today 2 different product lines: Hyper DC Inverter and Comfort DC Inverter.

• Efficiency • Energy savings • High performance in heating• Installation flexibility

All this in an environmentally responsible way.

The new outdoor units from the Hyper DC Inverter (4~6HP) line are capable of guaranteeing a high level of energy efficiency and a constant supply of heating power even with decreasing external temperatures.

• Minimum external heating temperature: -20° C. • Maximum splitting: 100 m.

Page 53: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

DC Inverter Hyper

DC Inverter Comfort

DC Inverter Hyper

DC Inverter Comfort

Due to application of blue coated fins for the heat exchanger of new outdoor unit, corrosion resistance has been improved compared to current models.

BLUE FIN

Keeping nominal heatingcapacity at -15°C nominal

heatingcapacity14.0kW

Heating capacity

4 min. 8 min.

Heating capacity

New Hyper DC Inverter line

Refer to the technical specifications regarding: application conditions, range of operation and heating/cooling capabilities.

The Hyper DC Inverter line guarabtees exceptional heating capacity in particularly cold geographical areas.

High performance heating is guaranteed by: • Optimization of refrigerator control, through the use of electronic expansion valves • Development of Twin Rotary Compressors

Outdoor units from the Hyper DC Inverter linekeep the nominal capacity in heating constant even when external temperatures reach -15° C.

The temperature of outgoing air in the indoor units can reach 40° C in just 4 minutes after the unit has been switched on, in heating mode, even when the operating conditions of outdoor units register a temperature of 2° C. The air temperature can reach 50° C during the next 8 minutes.

High performance heating

Model nominal heating capacity(kW at an external temperature of 7°C)

heating capacity(kW at an external temperature of -15°C)

FDT 100 VSX (4HP) 11,2 kW 11,2 kW

FDT 125 VSX (5HP) 14,0 kW 14,0 kW

FDT 140 VSX (6HP) 16,0 kW 16,0 kW

Page 54: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

342

mm

Refrigerant System ControlThe refrigeration circuit has been improved:• Optimum heat exchanger refrigerant

distribution.• Advanced refrigerant liquid return

protection control system.• High speed system control by new

Superlink system.

Employment of DC twin rotary compressor has enabled to utilize a high-speed range of up to 120 rps at the maximum to secure the required capacity. Optimum compressor control has been realized by employing the vector control and the starting current has been improved significantly compared with former models. Moreover, vibration has been reduced.

Twin Rotary compressor (Comfort DC Inverter line, 4~6HP)

Reduction in height by 22.3%Reduction in volume by 44.1%

previousmodel

newmodel

Inverter Control (Vector)The new Inverter Control uses the new advanced technology Vector to achieve high efficiency.• Smooth operation from low speed to

high speed.• Smooth Sine Voltage Wave form are

attained.• Energy efficiency is further improved

in low speed range.

Heat Exchanger(Comfort DC Inverter line)

• Optimization of the ratio between air flow and fin design.

• Improved air distribution.• Maximisation of the efficiency of the

heat exchanger.• New treatment of the condensor

fins (KS101) for improved corrosion resistance even in aggressive environments.

previous model

newmodel

The possibility to obtain an outdoor signal from the indoor unit card in order to inform about the working status – emergency block, compressor in cooling/heating – and also the possibility to turn on by the PC, land line, vocal order, badge reader, infrared, etc.

Remote monitoring

Hyper DC Inverter and Comfort DC Inverter lines

Page 55: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

-20° C

-15 °C

Heating

Cooling

+20° C

+43° C

-20° C

+43° C

Hyper DC Inverter line

Flexibility of installation

The reduction of the number of cores in the control wire.

New remote control for all indoor units

Total piping lenght 100 m

Outdoor units

Indoor unit

Heightdifference(Outdoor higherthan Indoor)

Comfort DC Inverter line

Total piping lenght 70 m (8~10HP)

Outdoor units

Indoor unit

Heightdifference(Outdoor higherthan Indoor)

HP Total piping lenght Height difference

4~6 100 m 30 m

HP Total piping lenght Height difference

4~6 50 m 30 m

8~10 70 m 30 m

The maximum length of the refrigeration pipes in the models in the Hyper Inverter DC and Comfort DC Inverter lines can reach 100 m and 70 m respectively, for models with 8 and 10HP; and the maximum height difference between indoor units is 15 m. Each unit is also provided with pre-charged refrigerant, sufficient for splittings of 30 m. The versatility offered by the number of installation possibilities is also shown in the possibility of centralising the air conditioning system using the Superlink network, by applying SC-ADNA-E interface to each indoor unit to be controlled.

Piping Length

previous system3 core

new system2 core

The Hyper DC Inverter and Comfort DC Inverter permit system operation in heating and cooling mode under low temperature conditions down to -20° C (except for FDC 200~250VS).

Range operation

30 m 30 m

Page 56: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Commercial Range Conter

High energy performance, maximum reliability over time, silent operation and an elegant and modern design are the characteristics of quality air-conditioning. The application solutions offered by the Hyper DC Inverter and Comfort DC Inverter product lines meet the installation requirements, of both medium and small commercial spaces, as well as large residential units. A wide choice of indoor units - 84x84 cassette, ceiling and ducted - with power range from 7,10 to 25,00 kW, for effective solutions for different installation requirements. All proposed installation solutions are developed with PAM DC inverter technology, using environmentally friendly R410A refrigerant gas and, in most cases, fall within Class A in cooling and heating.

Conter MonoThe current configuration of Conter mono products allows the installation of the indoor and outdoor units at greater distances from each other. Each unit is equipped with a pre-charge of refrigerant sufficient for splittings of 30 meters. The reduction in the size, weight and sound impact facilitate their inclusion in constricted urban environments or prestigious properties.

Conter mono outdoor units can be used in Twin, Triple and Double Twin configurations. The indoor units in combination will need to be of the same type and have the same capacity.

Conter Twin, Triple e Double TwinThe V Multi configuration uses some indoor and outdoor units with free combining by installation type, within the limits of the possible combinations. This great flexibility of application makes Mitsubishi Conter V Multi an innovative system. The V Multi system allows you to connect up to 4 indoor units to a single

Conter V Multi

Refer to pp. 76-77 for combined indoor units in Twin, Triple, Double Twin and V Multi application.

THE CONTER APPLICATION SOLUTIONS

Conter indoor units Conter Hyper DC Inverter and Comfort DC Inverter

Model 4-ways cassette84x84 FDT VD

Ducted mediumFDUM VD

Ducted highFDU VD

CeilingFDEN VD

k

W

7,1

10,0

12,5

14,0

20,0

25,0

Page 57: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

• 2 product lines• high splitting lenght• exceptional heating capacity at -15° C

outdoor unit. This allows a more rational use and greater efficiency for applications installed in medium to large sized open space environments and in environments with irregular boundaries.

All units operate simultaneously in the same mode (cooling and heating), maximizing energy efficiency and ensuring a significant reduction in operating costs.

VN/VNX = 1 PhaseVS/VSX = 3 Phase

O.U. Conter Comfort DC Inverter O.U. Conter Hyper DC Inverter

Model FDC 71VN FDC 100~140VN/VS FDC 200VS FDC 250VS FDC 100~140VNX/VSX

k

W

7,1

10,0

12,5

14,0

20,0

25,0

Page 58: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

4-ways cassette 84x84 FDT 100~140VD

4 way cassette available in 3capacities (10,0~14,0 kW)

Wireless Remote Control Kit withRCN-T-36W-E (optional)

Detachable covers at the four corners for easier installation

Easy checking of condensate drain pan condition

Extremely high splitting distance:100 m

Operating range, in cooling with an outdoor temperature as low as -15° Cand in heating with an outdoor temperature as low as -20° C

Condensate drain pump included

New design of the air louversAccording to room temperature conditions, 4 directions of air flow can be controlled by individual flap as preferred. As individual flap control is available even after installation, installation area becomes wider than before.

Superlink II connectionThe units can be connected toRC-E4 wired remote control and to Superlink II system, thanks to the optional interface SC-ADNA-E interface.

Page 59: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

FDT 100VD FDT 100VD FDT 125VD FDT 125VD FDT 140VD FDT 140VD

FDC 100VNX FDC 100VSX FDC 125VNX FDC 125VSX FDC 140VNX FDC 140VSX

DC-Inverter

10,00 10,00 12,50 12,50 14,00 14,00

11,20 11,20 14,00 14,00 16,00 16,00

2,50 2,50 3,28 3,28 4,19 4,19

2,58 2,58 3,43 3,43 4,20 4,20

4,00 / A 4,00 / A 3,81 / A 3,81 / A 3,34 / A 3,34 / A

4,34 / A 4,34 / A 4,08 / A 4,08 / A 3,81 / A 3,81 / A

1250 1250 1640 1640 2095 2095

1-220~240V-50HZ 3-380~400V-50HZ 1-220~240V-50HZ 3-380~400V-50HZ 1-220~240V-50HZ 3-380~400V-50HZ

O.U.

24-24 15-15 24-26 15-15 24-26 15-15

3

9,52 (3/8") - 15,88 (5/8")

100

30/15

4,50

30

60

-15°C~+43°C

-20°C~+20°C

298x840x840

27

40/37/35 40/37/35 42/40/37 42/40/37 43/41/38 43/41/38

32/29/27 32/29/27 34/32/29 34/32/29 35/33/30 35/33/30

1620/1440/1200 1620/1440/1200 1800/1620/1380 1800/1620/1380 1800/1620/1380 1800/1620/1380

20

1300x970x370

105

48 - 40 49 - 41

6000

T-PSA-3AW-E

35x950x950

5,5

RCN-T-36W-E

RC-E4

RCH-E3

Indoor Unit Model

Outdoor Unit Model

Type

CapacityCooling kW

Heating kW

Power Input Cooling kW

Heating kW

EER

COP

Annual Consumption (cooling) (500h/year) kW

Power supplyPh-V-Hz

I.U.~O.U.

Input Rated Current (Cooling - Heating) A

Wiring cables i.u./o.u. (without ground) n°

Refrigerant Pipe Liquid/Gas side inch.

Max splitting distance indoor/outdoor m

Max splitting level difference (out.-ind./ind.-out.) m

Refrigerant Precharge Kg

MAX Splitting without Refrigerant Precharge m

Additional Refrigerant Charge g/m

Temperature range cooling °C

Temperature range heating °C

Indoor Unit Specifications

Indoor Unit Dimension (HxWxD) mm

Net weight Kg

Indoor Noise level 1 m (Hi/Mi/Lo) dB(A)

Indoor Noise level 2,5 m (Hi/Mi/Lo) dB(A)

Indoor air flow (Hi/Mi/Lo) m3/h

Drain hose diameter mm

Outdoor Unit Specifications

Outdoor UnitDimension (HxWxD) mm

Net weight Kg

Max noise level 1 - 2,5 m dB(A)

Max air flow m3/h

Accessories

Panel

Panel dataDimension (HxWxD) mm

Net weight kg

Optional parts

Remote control KIT

Wired remote control

Basic wired remote control

Page 60: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Ducted medium FDUM 100~140VD

Drain pump included (60 cm)Included drain pump with 60 cm from the base of the unit allows for greater flexibility in layout and installation.

Ducted medium static pressure units available in 3 capacities (10,0~14,0 kW)

Energy class A, both in heating and in cooling (10,0~12,5 kW)

Extremely high splitting distance:100 m

Perfect for small/medium rooms

Operating range, in cooling with an outdoor temperature as low as -15° Cand in heating with an outdoor temperature as low as -20° C

Filter kit (optional) UM-FL3E(FDUM 100~140VD)

less than

600 mm

Flexible hose

Superlink II connectionThe units can be connected toRC-E4 wired remote control and to Superlink II system, thanks to the optional interface SC-ADNA-E interface.

Page 61: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

FDUM 100VD FDUM100VD FDUM 125VD FDUM125VD FDUM 140VD FDUM 140VD

FDC 100VNX FDC 100VSX FDC 125VNX FDC 125VSX FDC 140VNX FDC 140VSX

DC-Inverter

10,00 10,00 12,50 12,50 14,00 14,00

11,20 11,20 14,00 14,00 16,00 16,00

2,72 2,72 3,62 3,62 4,34 4,34

2,95 2,95 3,77 3,77 4,69 4,69

3,68 / A 3,68 / A 3,45 / A 3,45 / A 3,23 / A 3,23 / A

3,80 / A 3,80 / A 3,71 / A 3,71 / A 3,41 / B 3,41 / B

1360 1360 1810 1810 2170 2170

1-220~240V-50HZ 3-380~400V-50HZ 1-220~240V-50HZ 3-380~400V-50HZ 1-220~240V-50HZ 3-380~400V-50HZ

O.U.

24-24 15-15 24-26 15-15 24-26 15-15

3 3 3 3 3 3

9,52 (3/8") - 15,88 (5/8")

100

30/15

4,50

30

60

-15°C~+43°C

-20°C~+20°C

350x1370x635

59

37/35/32 38/36/33

29/27/24 30/28/25

1680/1500/1320 2040/1860/1620

standard 60/55 max 85/100

20

1300x970x370

105

48 - 40 49 - 41

6000

RC-E4

RCH-E3

RCN-KIT3-E

Indoor Unit Model

Outdoor Unit Model

Type

CapacityCooling kW

Heating kW

Power Input Cooling kW

Heating kW

EER

COP

Annual Consumption (cooling) (500h/year) kW

Power supplyPh-V-Hz

I.U.~O.U.

Input Rated Current (Cooling - Heating) A

Wiring cables i.u./o.u. (without ground) n°

Refrigerant Pipe Liquid/Gas side inch.

Max splitting distance indoor/outdoor m

Max splitting level difference (out.-ind./ind.-out.) m

Refrigerant Precharge Kg

MAX Splitting without Refrigerant Precharge m

Additional Refrigerant Charge g/m

Temperature range cooling °C

Temperature range heating °C

Indoor Unit Specifications

Indoor Unit Dimension (HxWxD) mm

Net weight Kg

Indoor Noise level 1 m (Hi/Mi/Lo) dB(A)

Indoor Noise level 2,5 m (Hi/Mi/Lo) dB(A)

Indoor air flow (Hi/Mi/Lo) m3/h

Aavilable static pressure Pa

Drain hose diameter mm

Outdoor Unit Specifications

Outdoor UnitDimension (HxWxD) mm

Net weight Kg

Max noise level 1 - 2,5 m dB(A)

Max air flow m3/h

Optional parts

Wired remote control

Basic wired remote control

Remote control KIT

Page 62: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

60

Ducted high FDU 100~140VD

Drain pump included (60 cm)Included drain pump with 60 cm from the base of the unit allows for greater flexibility in layout and installation.

less than

600 mm

Ducted high static pressure units available in 3 capacities (10,0~14,0 kW)

Return air intake from rear or from below

Condensate drain pump included, with 60 cm head

Extremely high splitting distance:100 m

Operating range, in cooling with an outdoor temperature as low as -15° Cand in heating with an outdoor temperature as low as -20° C

Superlink II connectionThe units can be connected toRC-E4 wired remote control and to Superlink II system, thanks to the optional interface SC-ADNA-E interface.

Page 63: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

61

FDU 100VD FDU100VD FDU 125VD FDU125VD FDU140VD FDU140VD

FDC 100VNX FDC 100VSX FDC 125VNX FDC 125VSX FDC 140VNX FDC 140VSX

DC-Inverter

10,00 10,00 12,50 12,50 14,00 14,00

11,20 11,20 14,00 14,00 16,00 16,00

2,78 2,78 3,44 3,44 4,20 4,20

2,9 2,9 3,67 3,67 4,30 4,30

3,60 / A 3,60 / A 3,63 / A 3,63 / A 3,33 / A 3,33 / A

3,86 / A 3,86 / A 3,81 / A 3,81 / A 3,72 / A 3,72 / A

1390 1390 1720 1720 2100 2100

1-220~240V-50HZ 3-380~400V-50HZ 1-220~240V-50HZ 3-380~400V-50HZ 1-220~240V-50HZ 3-380~400V-50HZ

O.U.

25-25 16-16 27-29 18-18 28-30 19-19

3

9,52 (3/8") - 15,88 (5/8")

100

30/15

4,50

30

60

-15°C~+43°C

-20°C~+20°C

350x1370x650

63

42/-/37 42/-/37 43/-/38 43/-/38 43/-/38 43/-/38

34/-/29 34/-/29 35/-/30 35/-/30 35/-/30 35/-/30

2040/-/1620 2040/-/1620 2520/-/2010 2520/-/2010 2520/-/2010 2520/-/2010

standard 50 max 130

20

1300x970x370

105

48 - 40 49 - 41

6000

RC-E4

RCH-E3

RCN-KIT3-E

Indoor Unit Model

Outdoor Unit Model

Type

CapacityCooling kW

Heating kW

Power Input Cooling kW

Heating kW

EER

COP

Annual Consumption (cooling) (500h/year) kW

Power supplyPh-V-Hz

I.U.~O.U.

Input Rated Current (Cooling - Heating) A

Wiring cables i.u./o.u. (without ground) n°

Refrigerant Pipe Liquid/Gas side inch.

Max splitting distance indoor/outdoor m

Max splitting level difference (out.-ind./ind.-out.) m

Refrigerant Precharge Kg

MAX Splitting without Refrigerant Precharge m

Additional Refrigerant Charge g/m

Temperature range cooling °C

Temperature range heating °C

Indoor Unit Specifications

Indoor Unit Dimension (HxWxD) mm

Net weight Kg

Indoor Noise level 1 m (Hi/Mi/Lo) dB(A)

Indoor Noise level 2,5 m (Hi/Mi/Lo) dB(A)

Indoor air flow (Hi/Mi/Lo) m3/h

Aavilable static pressure Pa

Drain hose diameter mm

Outdoor Unit Specifications

Outdoor UnitDimension (HxWxD) mm

Net weight Kg

Max noise level 1 - 2,5 m dB(A)

Max air flow m3/h

Optional parts

Wired remote control

Basic wired remote control

Remote control KIT

Page 64: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Ceiling FDEN 100~140VD

Installation FlexibilityFlexible installation: the refrigerant pipework can be installed in three different positions (on the back, on the top, to the right) as well as the drain pipework (on the left or right).

Top

Back

Right

Ceiling units available in 3 capacities (10,0~14,0 kW)

Energy class A, both in heating and in cooling (10,0~12,5 kW)

Extremely high splitting distance:100 m

Suitable for large spaces due to the powerful airflow

Operating range, in cooling with an outdoor temperature as low as -15° Cand in heating with an outdoor temperature as low as -20° C

Compact DesignEasy and fast installation withonly 25 cm height and 49 kgnet weight.

Superlink II connectionThe units can be connected toRC-E4 wired remote control and to Superlink II system, thanks to the optional interface SC-ADNA-E interface.

Page 65: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Indoor Unit Model FDEN 100VD FDEN 100VD FDEN 125VD FDEN 125VD FDEN 140VD FDEN 140VD

Outdoor Unit Model FDC 100VNX FDC 100VSX FDC 125VNX FDC 125VSX FDC 140VNX FDC 140VSX

Type DC-Inverter

CapacityCooling kW 10,00 10,00 12,50 12,50 14,00 14,00

Heating kW 11,20 11,20 14,00 14,00 16,00 16,00

Power Input Cooling kW 2,80 2,80 3,86 3,86 4,98 4,98

Heating kW 2,88 2,88 3,77 3,77 4,69 4,69

EER 3,57 / A 3,57 / A 3,24 / A 3,24 / A 2,81 / A 2,81 / A

COP 3,89 / A 3,89 / A 3,71 / A 3,71 / A 3,41 / B 3,41 / B

Annual Consumption (cooling) (500h/year) kW 1400 1930 2490

Power supplyPh-V-Hz 1-220~240V-50HZ 3-380~400V-50HZ 1-220~240V-50HZ 3-380~400V-50HZ 1-220~240V-50HZ 3-380~400V-50HZ

I.U.~O.U. O.U.

Input Rated Current (Cooling - Heating) A 24-24 15-15 24-26 15-15 24-26 15-15

Wiring cables i.u./o.u. (without ground) n° 3

Refrigerant Pipe Liquid/Gas side mm (inch.) 9,52 (3/8") - 15,88 (5/8")

Max splitting distance indoor/outdoor m 100

Max splitting level difference (out.-ind./ind.-out.) m 30/15

Refrigerant Precharge Kg 4,50

MAX Splitting without Refrigerant Precharge m 30

Additional Refrigerant Charge g/m 60

Temperature range cooling °C -15°C~+43°C

Temperature range heating °C -20°C~+20°C

Indoor Unit Specifications

Indoor Unit Dimension (HxWxD) mm 250x1620x690

Net weight Kg 49

Indoor Noise level 1 m (Hi/Mi/Lo) dB(A) 44/41/39 44/41/39 46/44/43 46/44/43 46/44/43 46/44/43

Indoor Noise level 2,5 m (Hi/Mi/Lo) dB(A) 36/33/31 36/33/31 38/36/35 38/36/35 38/36/35 38/36/35

Indoor air flow (Hi/Mi/Lo) m3/h 1560/1380/1260 1560/1380/1260 1740/1560/1380 1740/1560/1380 1740/1560/1380 1740/1560/1380

Drain hose diameter mm 20

Outdoor Unit Specifications

Outdoor UnitDimension (HxWxD) mm 1300x970x370

Net weight Kg 105

Max noise level 1 - 2,5 m dB(A) 48 - 40 49 - 41

Max air flow m3/h 6000

Optional parts

Wired remote control RC-E4

Basic wired remote control RCH-E3

Remote control KIT RCN-E1R

Page 66: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

64

4-ways cassette 84x84 FDT 71~140VD

Height reduction from 27 to 24,6 cm(FDT 71VD).

New design of the air louversAccording to room temperature conditions, 4 directions of air flow can be controlled by individual flap as preferred. As individual flap control is available even after installation, installation area becomes wider than before.

Low Profile designThe new design of the heat exchanger - reduced from 2 components to a single component - results in decrease in the unit height. Moreover, thanks to the application of DC fan motors, FDT units show high energy efficiencies levels, weight reduction and a very compact design.

4 way cassette available in 4 capacities (7,1~14,0 kW)

Wireless Remote Control Kit withRCN-T-36W-E (optional)

Detachable covers at the four corners for easier installation

Easy checking of condensate drain pan condition

Extremely high splitting distance:50 m

Operating range, in cooling with an outdoor temperature as low as -15° Cand in heating with an outdoor temperature as low as -20° C(-10° C FDT 71VD)

Condensate drain pump included

Superlink II connectionThe units can be connected toRC-E4 wired remote control and to Superlink II system, thanks to the optional interface SC-ADNA-E interface.

Page 67: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

65

FDT 71VD FDT 100VD FDT 100VD FDT 125VD FDT 125VD FDT 140VD FDT 140VD

FDC 71VN FDC 100VN FDC 100VS FDC 125VN FDC 125VS FDC 140VN FDC 140VS

DC-Inverter

7,10 (3,20~8,00) 10,00 (4,00~11,20) 10,00 (4,00~11,20) 12,50 (5,00~14,00) 12,50 (5,00~14,00) 14,00 (5,00~14,50) 14,00 (5,00~14,50)

8,00 (3,60~9,00) 11,20 (4,00~12,50) 11,20 (4,00~12,50) 14,00 (4,00~16,00) 14,00 (4,00~16,00) 16,00 (4,00~16,50) 16,00 (4,00~16,50)

1,90 2,76 2,76 4,05 4,05 4,98 4,98

2,07 2,74 2,74 3,77 3,77 4,57 4,57

3,74 / A 3,62 / A 3,62 / A 3,09 / B 3,09 / B 2,81 / C 2,81 / C

3,86 / A 4,09 / A 4,09 / A 3,71 / A 3,71 / A 3,50 / B 3,50 / B

950 1380 1380 2025 2025 2490 2490

1-220~240V-50HZ 1-220~240V-50HZ 3-380~400V-50HZ 1-220~240V-50HZ 3-380~400V-50HZ 1-220~240V-50HZ 3-380~400V-50HZ

O.U.

8,3 - 9,0 12,1 - 12,0 4,2 - 4,2 17,6 - 16,6 5,9 - 5,5 22,0 - 20,2 7,4 - 6,7

3

9,52 (3/8") - 15,88 (5/8")

50

30/15

2,95

30

60

-15°C~+43°C

-10°C~+20°C -20°C~+20°C

246x840x840 298x840x840

24 27

35/33/31 40/37/35 40/37/35 42/40/37 42/40/37 43/41/38 43/41/38

27/25/23 32/29/27 32/29/27 34/32/29 34/32/29 35/33/30 35/33/30

1260/1140/1020 1620/1440/1200 1620/1440/1200 1800/1620/1380 1800/1620/1380 1800/1620/1380 1800/1620/1380

20

750x968x340 845x970x370

60 81 83 81 83 81 83

48 - 40 49 - 41 49 - 41 50 - 42 51 - 43

3600 4500

T-PSA-3AW-E

35x950x950

5,5

RCN-T-36W-E

RC-E4

RCH-E3

Indoor Unit Model

Outdoor Unit Model

Type

CapacityCooling kW

Heating kW

Power Input Cooling kW

Heating kW

EER

COP

Annual Consumption (cooling) (500h/year) kW

Power supplyPh-V-Hz

I.U.~O.U.

Input Rated Current (Cooling - Heating) A

Wiring cables i.u./o.u. (without ground) n°

Refrigerant Pipe Liquid/Gas side inch.

Max splitting distance indoor/outdoor m

Max splitting level difference (out.-ind./ind.-out.) m

Refrigerant Precharge Kg

MAX Splitting without Refrigerant Precharge m

Additional Refrigerant Charge g/m

Temperature range cooling °C

Temperature range heating °C

Indoor Unit Specifications

Indoor Unit Dimension (HxWxD) mm

Net weight Kg

Indoor Noise level 1 m (Hi/Mi/Lo) dB(A)

Indoor Noise level 2,5 m (Hi/Mi/Lo) dB(A)

Indoor air flow (Hi/Mi/Lo) m3/h

Drain hose diameter mm

Outdoor Unit Specifications

Outdoor UnitDimension (HxWxD) mm

Net weight Kg

Max noise level 1 - 2,5 m dB(A)

Max air flow m3/h

Accessories

Panel

Panel dataDimension (HxWxD) mm

Net weight kg

Optional parts

Remote control KIT

Wired remote control

Basic wired remote control

Page 68: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Ducted medium FDUM 71~140VD

Drain pump included (60 cm)Included drain pump with 60 cm from the base of the unit allows for greater flexibility in layout and installation.

Ducted medium static pressure units available in 4 capacities (7,1~14,0 kW)

Energy class A, both in heating and in cooling (7,1~10,0 kW)

Extremely high splitting distance:50 m

Ultra-compact design: only 29,9 cm height (7,1 kW)

Operating range, in cooling with an outdoor temperature as low as -15° Cand in heating with an outdoor temperature as low as -20° C(-10° C FDUM 71VD)

Filter kit (optional) UM-FL2E (FDUM 71VD), UM-FL3E (FDUM 100~140VD)

less than

600 mm

Flexible hose

Superlink II connectionThe units can be connected toRC-E4 wired remote control and to Superlink II system, thanks to the optional interface SC-ADNA-E interface.

Page 69: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Indoor Unit Model FDUM 71VD FDUM100VD FDUM 100VD FDUM 125VD FDUM125VD FDUM 140VD FDUM 140VD

Outdoor Unit Model FDC 71VN FDC 100VN FDC 100VS FDC 125VN FDC 125VS FDC 140VN FDC 140VS

Type DC-Inverter

CapacityCooling kW 7,10 (3,20~8,00) 10,00

(4,00~11,20)10,00

(4,00~11,20)12,50

(5,00~14,00)12,50

(5,00~14,00)14,00

(5,00~14,50)14,00

(5,00~14,50)

Heating kW 8,00 (3,60~9,00) 11,20 (4,00~12,50)

11,20 (4,00~12,50)

14,00 (4,00~16,00)

14,00 (4,00~16,00)

16,00 (4,00~16,50)

16,00 (4,00~16,50)

Power InputCooling kW 2,08 2,80 2,80 4,03 4,03 4,95 4,95

Heating kW 2,21 2,77 2,77 3,80 3,80 4,89 4,89

EER 3,41 / A 3,57 / A 3,57 / A 3,10 / B 3,10 / B 2,83 / C 2,83 / C

COP 3,62 / A 4,04 / A 4,04 / A 3,68 / A 3,68 / A 3,27 / C 3,27 / C

Annual Consumption (cooling) (500h/year) kW 1040 1400 1400 2015 2015 2475 2475

Power supplyPh-V-Hz 1-220~240V-50HZ 1-220~240V-50HZ 3-380~400V-50HZ 1-220~240V-50HZ 3-380~400V-50HZ 1-220~240V-50HZ 3-380~400V-50HZ

I.U.~O.U. O.U.

Input Rated Current (Cooling - Heating) A 9,2 - 10,2 12,5 - 12,4 4,2 - 4,1 18,3 - 17,0 6,1 - 5,7 22,3 - 22,3 7,4 - 7,4

Wiring cables i.u./o.u. (without ground) n° 3

Refrigerant Pipe Liquid/Gas side mminch. 9,52 (3/8") - 15,88 (5/8")

Max splitting distance indoor/outdoor m 50

Max splitting level difference (out.-ind./ind.-out.) m 30/15

Refrigerant Precharge kg 2,95 3,80

MAX Splitting without Refrigerant Precharge m 30

Additional Refrigerant Charge g/m 60

Temperature range cooling °C -15°C~+43°C

Temperature range heating °C -10°C~+20°C -20°C~+20°C

Indoor Unit Specifications

Indoor Unit Dimension (HxWxD) mm 299x950x635 350x1370x635

Net weight kg 40 59 59 59 59 59 59

Indoor Noise level 1 m (Hi/Mi/Lo) dB(A) 35/32/29 37/35/32 37/35/32 38/36/33 38/36/33 38/36/33 38/36/33

Indoor Noise level 2,5 m (Hi/Mi/Lo) dB(A) 27/24/21 29/27/24 29/27/24 30/28/25 30/28/25 30/28/25 30/28/25

Indoor air flow (Hi/Mi/Lo) m3/h 1200/1080/900 1680/1500/1320 1680/1500/1320 2040/1860/1620 2040/1860/1620 2040/1860/1620 2040/1860/1620

Aavilable static pressure Pa standard 50/40 max 85/100 standard 60/60 max 90/100 standard 60/55 max 85/100

Drain hose diameter mm 20

Outdoor Unit Specifications

Outdoor UnitDimension (HxWxD) mm 750x968x340 845x970x370

Net weight kg 60 81 83 81 83 81 83

Max noise level 1 - 2,5 m dB(A) 48 - 40 49 - 41 50 - 42 51 - 43

Max air flow m3/h 3600 4500

Optional parts

Wired remote control RC-E4

Basic wired remote control RCH-E3

Remote control KIT RCN-KIT3-E

Page 70: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Ducted highFDU 71~140VD

Drain pump included (60 cm)Included drain pump with 60 cm from the base of the unit allows for greater flexibility in layout and installation.

less than

600 mm

Ducted high static pressure unit available in 4 capacities (7,1~14,0 kW)

Return air intake from rear or from below

Condensate drain pump included, with 60 cm head

Extremely high splitting distance:50 m

Operating range, in cooling with an outdoor temperature as low as -15° Cand in heating with an outdoor temperature as low as -20° C(-10° C FDU 71VD)

Compact dimensions: height only29,5 cm (FDU 71VD)

Superlink II connectionThe units can be connected toRC-E4 wired remote control and to Superlink II system, thanks to the optional interface SC-ADNA-E interface.

Page 71: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Indoor Unit Model FDU 71VD FDU 100VD FDU 100VD FDU 125VD FDU125VD FDU140VD FDU140VD

Outdoor Unit Model FDC 71VN FDC 100VN FDC 100VS FDC 125VN FDC 125VS FDC 140VN FDC 140VS

Type DC-Inverter

CapacityCooling kW 7,10 (3,20~8,00) 10,00 (4,00~11,20) 10,00 (4,00~11,20) 12,50 (5,00~14,00) 12,50 (5,00~14,00) 14,00 (5,00~14,50) 14,00 (5,00~14,50)

Heating kW 8,00 (3,60~9,00) 11,20 (4,00~12,50) 11,20 (4,00~12,50) 14,00 (4,00~16,00) 14,00 (4,00~16,00) 16,00 (4,00~16,50) 16,00 (4,00~16,50)

Power Input Cooling kW 2,08 2,88 2,88 4,04 4,04 4,95 4,95

Heating kW 2,21 2,99 2,99 3,79 3,79 4,43 4,43

EER 3,41 / A 3,47 / A 3,47 / A 3,09 / B 3,09 / B 2,83 / C 2,83 / C

COP 3,62 / A 3,75 / A 3,75 / A 3,69 / A 3,69 / A 3,61 / A 3,61 / A

Annual Consumption (cooling) (500h/year) kW 1040 1440 2020 2475

Power supplyPh-V-Hz 1-220~240V-50HZ 1-220~240V-50HZ 3-380~400V-50HZ 1-220~240V-50HZ 3-380~400V-50HZ 1-220~240V-50HZ 3-380~400V-50HZ

I.U.~O.U. O.U.

Input Rated Current (Cooling - Heating) A 9,2 - 10,2 12,7 - 13,1 4,3 - 4,4 17,8 - 16,6 6,0 - 5,6 21,7 - 19,5 7,4 - 6,6

Wiring cables i.u./o.u. (without ground) n° 3

Refrigerant Pipe Liquid/Gas side mm (inch.) 9,52 (3/8") - 15,88 (5/8")

Max splitting distance indoor/outdoor m 50

Max splitting level difference (out.-ind./ind.-out.) m 30/15

Refrigerant Precharge Kg 2,95 3,80

MAX Splitting without Refrigerant Precharge m 30

Additional Refrigerant Charge g/m 60

Temperature range cooling °C -15°C~+43°C

Temperature range heating °C -10°C~+20°C -20°C~+20°C

Indoor Unit Specifications

Indoor Unit Dimension (HxWxD) mm 295x850x650 350x1370x635

Net weight Kg 40 63

Indoor Noise level 1 m (Hi/Mi/Lo) dB(A) 41/-/37 42/-/37 42/-/37 43/-/38 43/-/38 43/-/38 43/-/38

Indoor Noise level 2,5 m (Hi/Mi/Lo) dB(A) 33/-/29 34/-/29 34/-/29 35/-/30 35/-/30 35/-/30 35/-/30

Indoor air flow (Hi/Mi/Lo) m3/h 1500/-/1200 2040/-/1620 2040/-/1620 2520/-/2010 2520/-/2010 2520/-/2010 2520/-/2010

Aavilable static pressure Pa standard 50 max 130

Drain hose diameter mm 20

Outdoor Unit Specifications

Outdoor UnitDimension (HxWxD) mm 750x968x340 845x970x370

Net weight Kg 60 81 83 81 83 81 83

Max noise level 1 - 2,5 m dB(A) 48 - 40 49 - 41 50 - 42 51 - 43

Max air flow m3/h 3600 4500

Optional parts

Wired remote control RC-E4

Basic wired remote control RCH-E3

Remote control KIT RCN-KIT3-E

Page 72: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Ducted high static pressure units available in 2 capacities (20,0~25,0 kW)

Return air intake from rear or from below

Ducted high static pressure 200 Pa

Ducted high FDU 200~250VD

High static pressureFDU 200 and 250VD units allow to extend the degree of freedom in the designing of the air-conditioning installation. The air flow can be set at 16 different speeds for improved comfort settings in every room (by using optional U-FCRA). Compact design: only 36 cm in height. Piping length up to 70 m.

Kit to control the speed of the air flow U-FCRA

Operating range, in cooling with an outdoor temperature as low as -15° Cand in heating with an outdoor temperature as low as -15° C

Control box

Thin type duct connection opening

High static pressure silent fan

Fan motor

Superlink II connectionThe units can be connected toRC-E4 wired remote control and to Superlink II system, thanks to the optional interface SC-ADNA-E interface.

Page 73: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Indoor Unit Model FDU 200VD FDU 250VD

Outdoor Unit Model FDC 200VS FDC 250VS

Type DC-Inverter

CapacityCooling kW 20,00 (7,00~22,40) 25,00 (10,00~28,00)

Heating kW 22,40 (7,60~25,00) 28,00 (9,50~31,50)

Power Input Cooling kW 6,59 9,91

Heating kW 6,08 8,50

EER 3,03 / B 2,52 / E

COP 3,68 / A 3,29 / B

Annual Consumption (cooling) (500h/year) kW 3295 4955

Power supplyPh-V-Hz 3-380~400V-50HZ

I.U.~O.U. O.U.

Input Rated Current (Cooling - Heating) A 10,8 - 10,2 15,7 - 14,4

Wiring cables i.u./o.u. (without ground) n° 3

Refrigerant Pipe Liquid/Gas side mm (inch.) 9,52 (3/8") - 22,22 (7/8")

Max splitting distance indoor/outdoor m 70

Max splitting level difference (out.-ind./ind.-out.) m 30/15

Refrigerant Precharge Kg 5,40 7,20

MAX Splitting without Refrigerant Precharge m 30

Additional Refrigerant Charge g/m 60 120

Temperature range cooling °C -15°C~+43°C

Temperature range heating °C -15°C~+20°C

Indoor Unit Specifications

Indoor Unit Dimension (HxWxD) mm 360x1570x830

Net weight Kg 92

Indoor Noise level 1 m (Hi/Mi/Lo) dB(A) 51/-/- 51/-/-

Indoor Noise level 2,5 m (Hi/Mi/Lo) dB(A) 43/-/- 43/-/-

Indoor air flow (Hi/Mi/Lo) m3/h 3060/-/- 4080/-/-

Aavilable static pressure Pa standard 100 max 200

Drain hose diameter mm 25

Outdoor Unit Specifications

Outdoor UnitDimension (HxWxD) mm 1300x970x370 1505x970x370

Net weight Kg 122 140

Max noise level 1 - 2,5 m dB(A) 57 - 49

Max air flow m3/h 9000

Optional parts

Wired remote control RC-E4

Basic wired remote control RCH-E3

Remote control KIT RCN-KIT3-E

Page 74: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Ceiling FDEN 71~140VD

Installation FlexibilityFlexible installation: the refrigerant pipework can be installed in three different positions (on the back, on the top, to the right) as well as the drain pipework (on the left or right).

Top

Back

Right

Ceiling units available in 4 capacities (7,1~14,0 kW)

Energy class A, both in heating and in cooling (7,1~10,0 kW)

Extremely high splitting distance:50 m

Suitable for large spaces due to the powerful airflow

Operating range, in cooling with an outdoor temperature as low as -15° Cand in heating with an outdoor temperature as low as -20° C(-10° C FDEN 71VD)

Compact DesignEasy and fast installation withonly 21 cm height (FDEN 71VD)and 37 kg net weight.

Superlink II connectionThe units can be connected toRC-E4 wired remote control and to Superlink II system, thanks to the optional interface SC-ADNA-E interface.

Page 75: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Indoor Unit Model FDEN 71VD FDEN 100VD FDEN 100VD FDEN 125VD FDEN 125VD FDEN 140VD FDEN 140VD

Outdoor Unit Model FDC 71VN FDC 100VN FDC 100VS FDC 125VN FDC 125VS FDC 140VN FDC 140VS

Type DC-Inverter

CapacityCooling kW 7,10 (3,20~8,00) 10,00 (4,00~11,20) 10,00 (4,00~11,20) 12,50 (5,00~14,00) 12,50 (5,00~14,00) 14,00 (5,00~14,50) 14,00 (5,00~14,50)

Heating kW 8,00 (3,60~9,00) 11,20 (4,00~12,50) 11,20 (4,00~12,50) 14,00 (4,00~16,00) 14,00 (4,00~16,00) 16,00 (4,00~16,50) 16,00 (4,00~16,50)

Power Input Cooling kW 2,01 2,85 2,85 4,10 4,10 4,98 4,98

Heating kW 2,21 2,97 2,97 3,65 3,65 4,69 4,69

EER 3,53 / A 3,51 / A 3,51 / A 3,05 / B 3,05 / B 2,81 / C 2,81 / C

COP 3,62 / A 3,77 / A 3,77 / A 3,84 / A 3,84 / A 3,41 / B 3,41 / B

Annual Consumption (cooling) (500h/year) kW 1005 1425 1425 2050 2050 2490 2490

Power supplyPh-V-Hz 1-220~240V-50HZ 1-220~240V-50HZ 3-380~400V-50HZ 1-220~240V-50HZ 3-380~400V-50HZ 1-220~240V-50HZ 3-380~400V-50HZ

I.U.~O.U. O.U.

Input Rated Current (Cooling - Heating) A 8,9 - 9,8 12,5 - 13,0 4,2 - 4,3 18,0 - 16,0 6,1 - 5,4 22,0 - 20,5 7,4 - 6,8

Wiring cables i.u./o.u. (without ground) n° 3

Refrigerant Pipe Liquid/Gas side mm (inch.) 9,52 (3/8") - 15,88 (5/8")

Max splitting distance indoor/outdoor m 50

Max splitting level difference (out.-ind./ind.-out.) m 30/15

Refrigerant Precharge Kg 2,95 3,80

MAX Splitting without Refrigerant Precharge m 30

Additional Refrigerant Charge g/m 60

Temperature range cooling °C -15°C~+43°C

Temperature range heating °C -10°C~+20°C -20°C~+20°C

Indoor Unit Specifications

Indoor Unit Dimension (HxWxD) mm 210x1320x690 250x1620x690

Net weight Kg 37 46

Indoor Noise level 1 m (Hi/Mi/Lo) dB(A) 41/39/38 44/41/39 44/41/39 46/44/43 46/44/43 46/44/43 46/44/43

Indoor Noise level 2,5 m (Hi/Mi/Lo) dB(A) 33/31/30 36/33/31 36/33/31 38/36/35 38/36/35 38/36/35 38/36/35

Indoor air flow (Hi/Mi/Lo) m3/h 1080/840/720 1560/1380/1260 1560/1380/1260 1740/1560/1380 1740/1560/1380 1740/1560/1380 1740/1560/1380

Drain hose diameter mm 20

Outdoor Unit Specifications

Outdoor UnitDimension (HxWxD) mm 750x968x340 845x970x370

Net weight Kg 60 81 83 81 83 81 83

Max noise level 1 - 2,5 m dB(A) 48 - 40 49 - 41 49 - 41 50 - 42 50 - 42 51 - 43 51 - 43

Max air flow m3/h 3600 4500

Optional parts

Wired remote control RC-E4

Basic wired remote control RCH-E3

Remote control KIT RCN-E1R

Page 76: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Unit Model SAF 250E4D SAF 500E4D SAF 800E4D SAF 1000E4D

Power supply Ph-V-Hz 1-220~240-50

Power input W 99~114 169~188 309~329 360~399

Running current A 0,46~0,48 0,79~0,81 1,48~1,50 1,85~1,93

Enthalpy exchange efficiency (cool./heat.) UHi % 63/70 62/67 65/71

Temperature exchange efficiency % 75

Enthalpy exchange efficiency (cool./heat.) Hi % 63/70 62/67 65/71

Temperature exchange efficiency % 75

Enthalpy exchange efficiency (cool./heat.) Lo % 66/73 77/67 68/74 68/73

Temperature exchange efficiency % 77 75 76

Motor / Quantity kW 20x2 35x2 81x2 118x2

Fan type / Quantity Centrifugal x 2

Air Flow Hi/Lo m3/h 250-170 500-370 800-650 1000-810

Available static pressure Hi/Lo Pa 80/37 70/38 110/70 55/35

Sound pressure level(Hi/Lo) dB(A) Hi 26 Lo 21 Hi 31 Lo 25 Hi 36,5 Lo 32 Hi 36 Lo 31

Air filterOutake intake air

Protection for element (washable) PS400Exhaust air

Dimensions (H x W x L) mm 270x882x599 270x962x904 388x1322x884

During heating operation in winter time the unit recovers part of the heat energy which would otherwise be exhausted to atmosphere, and uses this energy to warm the air entering the building.During cooling operation in summer time the exchange is more effective in warmer climates, where the exhausted cool air is used to partially cool the incoming air.

Capturing this waste energy means the heating/cooling requirements of the building are reduced, so smaller size plant can be selected, savings can be made in long term energy consumption and hazardous emissions are reduced.

Total heat recovery unitsSAF

Exhaust air

Outside air

Room Air

Supply air

Plate heat exchanger

Damper

Exhaust air

Room Air

Supply air

Outside air

e.g. for cooling in winter time

27 °C

10 °C27 °C

10 °C

33 °C

35 °C

29 °C

27 °Ce.g. heat exchange in summer time

Exhaust air

Room Air

Supply air

Outside air

Structure (SAF 1000E4) Principle of operation(heat exchanging)

Principle of operation(simple ventilation)

Page 77: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Conter Twin/Triple/Double Twin System

Conter V Multi System

Page 78: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Commercial Range

In this system the combined units must be the same model and the same capacity.

APPLICATION

Model kW 4,00 5,00 6,00 7,10 10,00 12,50

4-ways cassette 84x84 FDT

4-ways cassette 60x60 FDTC

Ducted mediumFDUM

Ceiling FDEN

Wall-mounted SRK*

Hyper DC Inverter Comfort DC Inverter

Outdoor units

FDC 100VNXFDC 100VSX

FDC 125VNXFDC 125VSX

FDC 140VNXFDC 140VSX FDC 71VN FDC 100VN

FDC 100VSFDC 125VNFDC 125VS

FDC 140VNFDC 140VS FDC 200VS FDC 250VS

Twin 50+50 60+60 71+71 40+40 50+50 60+60 71+71 100+100 125+125

Triple 50+50+50 50+50+50 71+71+71

Double Twin 50+50+50+50 60+60+60+60

* Can be selected for use as indoor units in the combination with Twin, Triple e Double Twin system outdoor units.

Page 79: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

In this system the combined units can be different model and different capacity.

Model kW 4,00 5,00 6,00 7,10 10,00 12,50

4-ways cassette 84x84 FDT

Ceiling FDEN

APPLICATION

Hyper DC Inverter Comfort DC Inverter

Outdoor units

FDC 100VNXFDC 100VSX

FDC 125VNXFDC 125VSX

FDC 140VNXFDC 140VSX FDC 71VN FDC 100VN

FDC 100VSFDC 125VNFDC 125VS

FDC 140VNFDC 140VS FDC 200VS FDC 250VS

Twin 50+50 60+6050+71 71+71 40+40 50+50 60+60

50+71 71+71 100+10071+125 125+125

Triple 50+50+50 50+50+50 71+71+71 60+60+12571+71+100

Double Twin 50+50+50+50 60+60+60+60

Gas line

Liquid line

Reducer

Gas line

Liquid line

Reducer

JOIN KIT

Gas line

Liquid line

Reducer

Gas line

Liquid line

Page 80: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

50+50 50+50 50+50 50+50 50+50

FDC 100VNX FDC 100VSX

10,00 10,00 10,00 10,00 10,00

2,56 2,78 2,94 3,02 2,66

3,91 3,60 3,40 3,31 3,76

11,20 11,20 11,20 11,20 11,20

2,66 3,02 2,94 3,18 2,60

4,21 3,71 3,81 3,52 4,31

30 35 28 37 26

DIS-WA1 DIS-WA1 DIS-WA1 DIS-WA1 DIS-WA1

60+60 60+60 60+60 60+60 60+60

FDC 125VNX FDC 125VSX

12,50 12,50 12,50 12,50 12,50

3,06 4,10 3,86 3,86 3,60

4,08 3,05 3,24 3,24 3,47

14,00 14,00 14,00 14,00 14,00

3,22 4,10 4,10 3,70 3,48

4,35 3,41 3,41 3,78 4,02

30 30 28 38 26

DIS-WA1 DIS-WA1 DIS-WA1 DIS-WA1 DIS-WA1

71+71 71+71 71+71 50+50+50 50+50+50 50+50+50 50+50+50 50+50+50

FDC 140VNX FDC 140VSX

14,00 14,00 14,00 14,00 14,00 14,00 14,00 14,00

3,88 4,60 4,78 3,88 4,34 4,60 4,72 3,98

3,61 3,04 2,93 3,61 3,23 3,04 2,97 3,52

16,00 16,00 16,00 16,00 16,00 16,00 16,00 16,00

3,70 4,69 4,43 3,76 4,34 4,69 4,38 3,68

4,32 3,41 3,61 4,26 3,69 3,41 3,65 4,35

31 29 38 30 35 28 37 26

DIS-WA1 DIS-WA1 DIS-WA1 DIS-TA1 DIS-TA1 DIS-TA1 DIS-TA1 DIS-TA1

Cooling capacity kW

Cooling input kW

EER

Heating capacity kW

Heating input kW

COP

I.U. Noise level (MIN.) dB(A)

Join KIT

Cooling capacity kW

Cooling input kW

EER

Heating capacity kW

Heating input kW

COP

I.U. Noise level (MIN.) dB(A)

Join KIT

Cooling capacity kW

Cooling input kW

EER

Heating capacity kW

Heating input kW

COP

I.U. Noise level (MIN.) dB(A)

Join KIT

Application of indoor units of the same model in a Conter Twin, Triple and Double Twin system

Page 81: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

50+50 50+50 50+50 50+50 50+50

FDC 100VNX FDC 100VSX

10,00 10,00 10,00 10,00 10,00

2,56 2,78 2,94 3,02 2,66

3,91 3,60 3,40 3,31 3,76

11,20 11,20 11,20 11,20 11,20

2,66 3,02 2,94 3,18 2,60

4,21 3,71 3,81 3,52 4,31

30 35 28 37 26

DIS-WA1 DIS-WA1 DIS-WA1 DIS-WA1 DIS-WA1

60+60 60+60 60+60 60+60 60+60

FDC 125VNX FDC 125VSX

12,50 12,50 12,50 12,50 12,50

3,06 4,10 3,86 3,86 3,60

4,08 3,05 3,24 3,24 3,47

14,00 14,00 14,00 14,00 14,00

3,22 4,10 4,10 3,70 3,48

4,35 3,41 3,41 3,78 4,02

30 30 28 38 26

DIS-WA1 DIS-WA1 DIS-WA1 DIS-WA1 DIS-WA1

71+71 71+71 71+71 50+50+50 50+50+50 50+50+50 50+50+50 50+50+50

FDC 140VNX FDC 140VSX

14,00 14,00 14,00 14,00 14,00 14,00 14,00 14,00

3,88 4,60 4,78 3,88 4,34 4,60 4,72 3,98

3,61 3,04 2,93 3,61 3,23 3,04 2,97 3,52

16,00 16,00 16,00 16,00 16,00 16,00 16,00 16,00

3,70 4,69 4,43 3,76 4,34 4,69 4,38 3,68

4,32 3,41 3,61 4,26 3,69 3,41 3,65 4,35

31 29 38 30 35 28 37 26

DIS-WA1 DIS-WA1 DIS-WA1 DIS-TA1 DIS-TA1 DIS-TA1 DIS-TA1 DIS-TA1

Cooling capacity kW

Cooling input kW

EER

Heating capacity kW

Heating input kW

COP

I.U. Noise level (MIN.) dB(A)

Join KIT

Cooling capacity kW

Cooling input kW

EER

Heating capacity kW

Heating input kW

COP

I.U. Noise level (MIN.) dB(A)

Join KIT

Cooling capacity kW

Cooling input kW

EER

Heating capacity kW

Heating input kW

COP

I.U. Noise level (MIN.) dB(A)

Join KIT

Page 82: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

40+40 40+40 40+40

FDC 71VN

7,10 7,10 7,10

1,85 1,91 1,74

3,84 3,72 4,08

8,00 8,00 8,00

1,99 2,08 1,84

4,02 3,85 4,35

30 35 37

DIS-WA1 DIS-WA1 DIS-WA1

50+50 50+50 50+50 50+50 50+50

FDC 100VNFDC 100VS

10,00 10,00 10,00 10,00 10,00

2,94 2,84 3,12 2,78 2,72

3,40 3,52 3,21 3,60 3,68

11,20 11,20 11,20 11,20 11,20

3,09 3,08 3,27 2,94 2,86

3,62 3,64 3,43 3,81 3,92

30 35 28 37 26

DIS-WA1 DIS-WA1 DIS-WA1 DIS-WA1 DIS-WA1

60+60 60+60 60+60 60+60 60+60

FDC 125VNFDC 125VS

12,50 12,50 12,50 12,50 12,50

3,95 5,35 4,47 4,23 4,25

3,16 2,34 2,80 2,96 2,94

14,00 14,00 14,00 14,00 14,00

3,70 4,62 4,51 3,83 4,29

3,78 3,03 3,10 3,66 3,26

30 30 28 38 26

DIS-WA1 DIS-WA1 DIS-WA1 DIS-WA1 DIS-WA1

71+71 71+71 71+71 50+50+50 50+50+50 50+50+50 50+50+50 50+50+50

FDC 140VNFDC 140VS

14,00 14,00 14,00 14,00 14,00 14,00 14,00 14,00

4,51 5,00 4,87 4,65 4,64 5,09 4,88 4,53

3,10 2,80 2,87 3,01 3,02 2,75 2,87 3,09

16,00 16,00 16,00 16,00 16,00 16,00 16,00 16,00

4,58 4,94 4,59 4,63 4,52 5,03 4,58 4,05

3,49 3,24 3,49 3,46 3,54 3,18 3,49 3,95

31 29 38 30 35 28 37 26

DIS-WA1 DIS-WA1 DIS-WA1 DIS-TA1 DIS-TA1 DIS-TA1 DIS-TA1 DIS-TA1

100+100 100+100 100+100 71+71+71 71+71+71 71+71+71 50+50+50+50 50+50+50+50 50+50+50+50 50+50+50+50 50+50+50+50

FDC 200VS

20,00 20,00 20,00 20,00 20,00 20,00 20,00 20,00 20,00 20,00 20,00

6,58 6,86 6,47 6,49 6,88 6,40 6,58 6,50 6,90 6,54 6,54

3,04 2,92 3,09 3,08 2,91 3,13 3,04 3,08 2,90 3,06 3,06

22,40 22,40 22,40 22,40 22,40 22,40 22,40 22,40 22,40 22,40 22,40

6,02 6,72 5,97 6,12 6,74 5,90 6,15 6,36 6,76 6,40 6,40

3,72 3,33 3,75 3,66 3,32 3,80 3,64 3,52 3,31 3,50 3,50

35 32 39 31 29 38 30 35 28 37 26

DIS-WB1 DIS-WB1 DIS-WB1 DIS-TB1 DIS-TB1 DIS-TB1 2 x DIS-WA1 2 x DIS-WA1 2 x DIS-WA1 2 x DIS-WA1 2 x DIS-WA1

1 x DIS-WB1 1 x DIS-WB1 1 x DIS-WB1 1 x DIS-WB1 1 x DIS-WB1

125+125 125+125 125+125 60+60+60+60 60+60+60+60 60+60+60+60 60+60+60+60 60+60+60+60

FDC 250VS

25,00 25,00 25,00 25,00 25,00 25,00 25,00 25,00

8,30 9,31 9,01 8,28 11,28 9,31 9,11 8,91

3,01 2,69 2,77 3,02 2,22 2,69 2,74 2,81

28,00 28,00 28,00 28,00 28,00 28,00 28,00 28,00

7,75 8,35 8,05 7,70 10,19 8,35 8,11 7,95

3,61 3,35 3,48 3,64 2,75 3,35 3,45 3,52

37 33 43 30 30 28 38 26

DIS-WB1 DIS-WB1 DIS-WB1 2 x DIS-WA1 2 x DIS-WA1 2 x DIS-WA1 2 x DIS-WA1 2 x DIS-WA1

1 x DIS-WB1 1 x DIS-WB1 1 x DIS-WB1 1 x DIS-WB1 1 x DIS-WB1

Cooling capacity kW

Cooling input kW

EER

Heating capacity kW

Heating input kW

COP

I.U. Noise level (MIN.) dB(A)

Join KIT

Cooling capacity kW

Cooling input kW

EER

Heating capacity kW

Heating input kW

COP

I.U. Noise level (MIN.) dB(A)

Join KIT

Cooling capacity kW

Cooling input kW

EER

Heating capacity kW

Heating input kW

COP

I.U. Noise level (MIN.) dB(A)

Join KIT

Cooling capacity kW

Cooling input kW

EER

Heating capacity kW

Heating input kW

COP

I.U. Noise level (MIN.) dB(A)

Join KIT

Cooling capacity kW

Cooling input kW

EER

Heating capacity kW

Heating input kW

COP

I.U. Noise level (MIN.) dB(A)

Join KIT

Cooling capacity kW

Cooling input kW

EER

Heating capacity kW

Heating input kW

COP

I.U. Noise level (MIN.) dB(A)

Join KIT

Application of indoor units of the same model in a Conter Twin, Triple and Double Twin system

Page 83: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

40+40 40+40 40+40

FDC 71VN

7,10 7,10 7,10

1,85 1,91 1,74

3,84 3,72 4,08

8,00 8,00 8,00

1,99 2,08 1,84

4,02 3,85 4,35

30 35 37

DIS-WA1 DIS-WA1 DIS-WA1

50+50 50+50 50+50 50+50 50+50

FDC 100VNFDC 100VS

10,00 10,00 10,00 10,00 10,00

2,94 2,84 3,12 2,78 2,72

3,40 3,52 3,21 3,60 3,68

11,20 11,20 11,20 11,20 11,20

3,09 3,08 3,27 2,94 2,86

3,62 3,64 3,43 3,81 3,92

30 35 28 37 26

DIS-WA1 DIS-WA1 DIS-WA1 DIS-WA1 DIS-WA1

60+60 60+60 60+60 60+60 60+60

FDC 125VNFDC 125VS

12,50 12,50 12,50 12,50 12,50

3,95 5,35 4,47 4,23 4,25

3,16 2,34 2,80 2,96 2,94

14,00 14,00 14,00 14,00 14,00

3,70 4,62 4,51 3,83 4,29

3,78 3,03 3,10 3,66 3,26

30 30 28 38 26

DIS-WA1 DIS-WA1 DIS-WA1 DIS-WA1 DIS-WA1

71+71 71+71 71+71 50+50+50 50+50+50 50+50+50 50+50+50 50+50+50

FDC 140VNFDC 140VS

14,00 14,00 14,00 14,00 14,00 14,00 14,00 14,00

4,51 5,00 4,87 4,65 4,64 5,09 4,88 4,53

3,10 2,80 2,87 3,01 3,02 2,75 2,87 3,09

16,00 16,00 16,00 16,00 16,00 16,00 16,00 16,00

4,58 4,94 4,59 4,63 4,52 5,03 4,58 4,05

3,49 3,24 3,49 3,46 3,54 3,18 3,49 3,95

31 29 38 30 35 28 37 26

DIS-WA1 DIS-WA1 DIS-WA1 DIS-TA1 DIS-TA1 DIS-TA1 DIS-TA1 DIS-TA1

100+100 100+100 100+100 71+71+71 71+71+71 71+71+71 50+50+50+50 50+50+50+50 50+50+50+50 50+50+50+50 50+50+50+50

FDC 200VS

20,00 20,00 20,00 20,00 20,00 20,00 20,00 20,00 20,00 20,00 20,00

6,58 6,86 6,47 6,49 6,88 6,40 6,58 6,50 6,90 6,54 6,54

3,04 2,92 3,09 3,08 2,91 3,13 3,04 3,08 2,90 3,06 3,06

22,40 22,40 22,40 22,40 22,40 22,40 22,40 22,40 22,40 22,40 22,40

6,02 6,72 5,97 6,12 6,74 5,90 6,15 6,36 6,76 6,40 6,40

3,72 3,33 3,75 3,66 3,32 3,80 3,64 3,52 3,31 3,50 3,50

35 32 39 31 29 38 30 35 28 37 26

DIS-WB1 DIS-WB1 DIS-WB1 DIS-TB1 DIS-TB1 DIS-TB1 2 x DIS-WA1 2 x DIS-WA1 2 x DIS-WA1 2 x DIS-WA1 2 x DIS-WA1

1 x DIS-WB1 1 x DIS-WB1 1 x DIS-WB1 1 x DIS-WB1 1 x DIS-WB1

125+125 125+125 125+125 60+60+60+60 60+60+60+60 60+60+60+60 60+60+60+60 60+60+60+60

FDC 250VS

25,00 25,00 25,00 25,00 25,00 25,00 25,00 25,00

8,30 9,31 9,01 8,28 11,28 9,31 9,11 8,91

3,01 2,69 2,77 3,02 2,22 2,69 2,74 2,81

28,00 28,00 28,00 28,00 28,00 28,00 28,00 28,00

7,75 8,35 8,05 7,70 10,19 8,35 8,11 7,95

3,61 3,35 3,48 3,64 2,75 3,35 3,45 3,52

37 33 43 30 30 28 38 26

DIS-WB1 DIS-WB1 DIS-WB1 2 x DIS-WA1 2 x DIS-WA1 2 x DIS-WA1 2 x DIS-WA1 2 x DIS-WA1

1 x DIS-WB1 1 x DIS-WB1 1 x DIS-WB1 1 x DIS-WB1 1 x DIS-WB1

Cooling capacity kW

Cooling input kW

EER

Heating capacity kW

Heating input kW

COP

I.U. Noise level (MIN.) dB(A)

Join KIT

Cooling capacity kW

Cooling input kW

EER

Heating capacity kW

Heating input kW

COP

I.U. Noise level (MIN.) dB(A)

Join KIT

Cooling capacity kW

Cooling input kW

EER

Heating capacity kW

Heating input kW

COP

I.U. Noise level (MIN.) dB(A)

Join KIT

Cooling capacity kW

Cooling input kW

EER

Heating capacity kW

Heating input kW

COP

I.U. Noise level (MIN.) dB(A)

Join KIT

Cooling capacity kW

Cooling input kW

EER

Heating capacity kW

Heating input kW

COP

I.U. Noise level (MIN.) dB(A)

Join KIT

Cooling capacity kW

Cooling input kW

EER

Heating capacity kW

Heating input kW

COP

I.U. Noise level (MIN.) dB(A)

Join KIT

Page 84: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

82

Cooling capacity kW

Cooling input kW

EER

Heating capacity kW

Heating input kW

COP

U.I. Noise level (MIN) dB(A)

Join KIT

Cooling capacity kW

Cooling input kW

EER

Heating capacity kW

Heating input kW

COP

U.I. Noise level (MIN) dB(A)

Join KIT

Cooling capacity kW

Cooling input kW

EER

Heating capacity kW

Heating input kW

COP

U.I. Noise level (MIN) dB(A)

Join KIT

Cooling capacity kW

Cooling input kW

EER

Heating capacity kW

Heating input kW

COP

U.I. Noise level (MIN) dB(A)

Join KIT

Cooling capacity kW

Cooling input kW

EER

Heating capacity kW

Heating input kW

COP

U.I. Noise level (MIN) dB(A)

Join KIT

Cooling capacity kW

Cooling input kW

EER

Heating capacity kW

Heating input kW

COP

U.I. Noise level (MIN) dB(A)

Join KIT

Application of indoor units of different model in a Conter V Multi system

Page 85: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Individual controlsStandard infrared control (see specifications for every single unit)

Wired remote control RC-E1R/RC-E4 (optional)Simple wired remote control RCH-E3 (optional)Infrared control RCN-E1R (optional)Infrared receiver KIT RCN-KIT3-E (optional)Infrared receiver KIT RCN-TC-24W-ER (optional)Infrared receiver KIT RCN-T-36W-E (optional)

Superlink IICentral controller SC-SL1N-ECentral controller SC-SL2NA-ECentral controller LCD SC-SL3NA-AE/BEWeb gateway SC-WGWNA-A/BBACnet gateway SC-BGWNA-A/BLONworks gateway SC-LGWNA-A

Page 86: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Individual controls

• Automatic sanitization against moulds

• Sleep function

• Manual setting of bi-directional louver swing

• Programmed 3D Auto air flow

• Manual setting of CLEAN function of the anti-allergenic filter

• Automatic sanitization against moulds

• Sleep function

• Manual setting of bi-directional louver swing

• Manual setting of CLEAN function of the anti-allergenic filter (SRK ZE-S1)

• HI POWER/ECONO mode to reach the desired temperature as quick as possible

• Automatic sanitization against moulds

• Sleep function

• Manual setting of the louver swing

• HI POWER/ECONO mode, to reach the desired temperature as quick as possible

• Manual setting of the louver swing (STM ZF-S)

• ECONO mode, for energy saving and a reduced noise level

• HI POWER mode, to reach the desired temperature as quick as possible

• RESERVE MODE, to store and set clock and timer settings

Applicable to: SRK ZJX-S, SRK ZJ-S,SRK ZG-S, SKM ZG-S

Applicable to: SRK ZGX-S, SRK ZE-S1

Applicable to: SRK HG-S, SRF ZJX-S, SRR ZJ-S

Applicable to: STM ZF-S, SRRM ZF-S

Standard infrared controls

Page 87: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Wired remote control with LCD display Basic wired remote control

Optional for: FDT, FDTC, FDU, FDUM, FDEN

Optional for: FDU, FDUM

Wireless infrared remote control kit

Optional for: FDT

Optional for: FDTC

Optional for: FDEN

Wireless infrared remote control kit

Wireless infrared remote control kit Wireless infrared remote control kit

*Applicable only to SRK ZE-S1 and Residential multisplit indoor units.

Wired remote control with LCD display: the largedisplay area and the clear LCD enables convenient access to operation and service data.• Standard weekly timer function• Room temperature sensor integrated in the remote

control unit• Adjustable set temperature ranges• 4 ventilation speed• Data saving function

Specifically suited for application in hotels and small offices, this wired controller is simple to use and provides the basic control functions• On/Off• Mode• Temp. setting• Fan speed• AutorestartThe basic wired remote control allows the individual control of up to 16 indoor units.

Optional controls

Page 88: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Superlink II

Superlink-II is an advanced high speed data transmission network that can connect and control up to 128 indoor units. It is a comprehensive control and management system, capable of meeting the demands of building owners and occupiers in large or small applications.

The Superlink II control system is inexpensive to install utilising two wire non-polar cable for the complete network.

In case of integrated installation of Residential indoor units (SKM/STM/SRRM ZG-S, SRK ZG-S, SRK ZE-S1), it is required to set all units on Superlink I protocol, to use the interfaces for 3-wires networks SC-BIK1-E and SC-AD-ER and to control the units by RC-E1R wired control.

I.U. Multi-KX6

I.U. Multi-KX6MICRO KX System

KX6-KXR6 System

Units PAC(Comfort and Hyper)

Twin, V Multi

KX6-KXR6 System

O.U. RAC multi

remote control

I.U. Multi-KX6

O.U. PAC (Comfort and Hyper)O.U. RAC

Page 89: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

Superlink II - controls

Central controller

SC-SL 1N-E central controller is connected to the Superlink II network via 2-core non-polar wires. It monitors and controls the on/off function of up to 16 indoor units.The unit numbers in operation or in need of service are indicated by specific LED’s.Up to 12 SC-SL1N-E central controllers can be installed with a Superlink II network, controlling a total of up to 128 indoor units.

SC-SL2NA-E central controller is connected to the Superlink II network via 2-core non-polar wires. It monitors and controls the on/off function of up to 16 indoor units, or 16 groups of units, for central control of up to 64 units. It also monitors and controls the following functions for each unit, group of units, or the complete network: operation mode, temperature set point, louvre position, error code. The LCD display shows the unit or group numbers in operation and identifies those in need of service. The timer is connected to the central controller for on/off cycle control. The central controller can be connected at any point in the Superlink II network, at the indoor or outdoor units. This can substantially reduce the amount of electrical cabling required for the installation.

SC-SL3NA-AE/BE is a full colour touch screen central control with 7 inch interactive display. The central control panel provides control, monitoring, service and maintenance functions for all indoor units connected to the Superlink II network.SC-SL3NA-BE offers an electrical power consumption calculation function for each indoor unit or group.It offers the possibility of exporting the data to a USB memory stick and editing and organising this data in an Excel spreadsheet. The necessary software is supplied with the central control panel.

Web gateway SC-WGWNA-A/SC-WGWNA-B

This central control provides a simple management system for small and medium installations, including electrical power consumption data, and can be utilised for the control of up to 128 indoor units in up to 96 groups (64 indoor units x 2 Superlink II networks). Secure and simple to install, all that is required is Internet Explorer. An IP address filter function is included, together with three-level user authentication for security.SC-WGWNA-B offers an electrical power consumption calculation function for each indoor unit or group.

Central controller

Central controller

Page 90: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative

BACnet gatewaySC-BGWNA-A/SC-BGWNA-BThis interface device operates on the BACnet protocol for the central control of the air conditioning system on a BACnet network. It can be used for the interfacing of up to 128 indoor units in up to 96 groups (64 indoor units x 2 Superlink II networks).SC-BGWNA-B offers an electrical power consumption calculation function for each indoor unit or group.

LonWorks gatewaySC-LGWNA-A

Due to the continous improvement policy, we reserve the right to make changes in all specifications without notice.

This interface device allows the interfacing, monitoring, and control of the MHI indoor units on a LonWorks network, by converting the Superlink II communication data to the LonWorks protocol. It can be used for the control and monitoring of up to 96 indoor units, which is the highest number of units for a LonWorks system interface device available on the market.

In case of integrated installation of Residential indoor units (SKM/STM/SRRM ZG-S, SRK ZG-S, SRK ZE-S1), it is required to set all units on Superlink I protocol, to use the interfaces for 3-wires networksSC-BIK1-E and SC-AD-ER and to control the units by RC-E1R wired control.

SC-ADNA-E interface

This interface can create a 2-wires, X,Y, network on wall-mounted units, enabling their control thanks to RC-E4 wired controller.Moreover, using SC-ADNA-E interface, directly connected to SC-BIKN-E, you can have a Superlink II network and centralize the control of thewall-mounted units using remote controls, for all functions.The interface is in a box (120X135x29 mm) and can be clamped to the wall. The interface is also equipped with a CnT connector, so that wall-mounted units can exchange digital input/output with an external control system.

Optional KIT SC-BIKN-E

Superlink II - controls

Applicable interfaceWired control network Superlink II network

This interface enables the connection of the Superlink II network to oudoor units, so to be in a position to manage them via a SC-SL2N-E device and other centralized controls.Functions:• transmission of information of Superlink II bus data with addressing of

the connected indoor units;• possibility of blocking the adjustment of the single indoor units from

centralized control (remote);• transmission of any error message relevant to the indoor units

connected to Superlink II, displaying error code.

Model Interface Controls

SRK 71 ZE-S1,SKM 60, 71 ZG-S, SRRM, STM

-RC-E1R

SRK 20~50 ZG-SSKM 20~50 ZG-S SC-BIK1-E

SRK 20~60 ZJX-SSRF 25~50 ZJX-SSRR 25~60 ZJ-S

SC-BIKN-E RC-E4

Model Interface Controls

SRK 20~60 ZJX-SSRF 25~50 ZJX-SSRK 20~50 ZJ-SSRK 20~50 ZG-SSRR 25~35 ZJ-S

SC-BIKN-ESC-ADNA-E RC-E4 +

centralized

FDTC 25~60 VD SC-ADNA-E

SC-LGWNA-A

Page 91: Residential Light Commercial CommercialMitsubishi Heavy Industries venture into sectors of the greatest importance for the future of the planet, amongst which are research into alternative