8
MECHANISM AS SUPPLIED WWW.FUTUREAUTOMATION.NET CHRS4-RES TECHNICAL SHEET ISSUE 007 SHEET 1 RESIDENTIAL CEILING HINGE RANGE WITH SWIVEL UK +44 (0) 1438 833577 US +1 (603) 742 9181

RESIDENTIAL CEILING HINGE RANGE WITH SWIVEL

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

MECHANISM AS SUPPLIED

WWW.FUTUREAUTOMATION.NET

CHRS4-RES

TECHNICAL SHEETISSUE 007

SHEET 1

RESIDENTIAL CEILING HINGE RANGEWITH SWIVEL

UK +44 (0) 1438 833577 US +1 (603) 742 9181

SPECIFICATION MEASUREMENTSProduct Dimensions 1624mm [63 15/16"] W x 1185mm [46 10/16"] L x 210mm [8 4/16"] D

Product Weight 130Kg [287lb]

Maximum Screen Size 1130mm [44 8/16"] W x 680mm [26 12/16"] L x 100mm [3 15/16"] D

Maximum Weight Capacity 45Kg [99lb] Max. *Assuming Screen Weight Biased Low (3/4 Screen Height)

Packaging Dimensions 1660mm [65 6/16"] W x 1360mm [53 9/16"] L x 440mm [17 5/16"] D

Shipping Weight 199Kg [439lb]

Maximum Rotation 90 on Hinge, 180° CW and CCW on Swivel

Movement Type Motorised

Control System Housed Internally - Accessible by Internal Access Hatch

Power Supply Required 110V - 240V AC 50/60Hz

Power Consumption Max. 720W

Power Consumption Standby 3W

Mounting Patterns Supported VESA 400, 300, 200 W x 400, 300, 200 H

Control Options IR Remote, RS232, Contact Closure

Product Options / Features Specific B&O and Loewe mounts / adapters, Custom RAL paint finishes, Marine suitable version

Package Contents Mechanism, IR remote control

Environment Residential / Commerical

Colour WHITE - RAL9910 Satin Finish

Marine Suitable No - Marine Indoor and Outdoor Versions Available

WWW.FUTUREAUTOMATION.NET

CHRS4-RES

TECHNICAL SHEETISSUE 007

SHEET 2

RESIDENTIAL CEILING HINGE RANGEWITH SWIVEL

UK +44 (0) 1438 833577 US +1 (603) 742 9181

2 9/16" + 3/16"0"

65 + 50

3 15/16" min.

100 min.

1 7/8" + 1/8"0"

47 + 30

SECTION A-ASCALE 1 : 3

Structural Joist

Outer Battening For Plasterboard / Gyproc

12.5 [0.5"] Plasterboard / Gyproc

Mounting Block

MDF Plaster Edge Trims

3 [0.1"] Plaster Skim

Tray Flush With Ceiling

3 1/2" min.

89 min.

Mounting Joist Width

64 3/16" + 3/16"0"

1630 + 50

50 9/16" ±1/4"

1285 ±6

8"203

13 9/16" ±1"

345 ±25

1 1/4" min.32 min.

Cable Routing on Either Side

Suitable Fixings to Secure Mechanism Into Ceiling Void (Not Supplied)

Screws to secure MDF Plaster Edge to Ceiling Structure(Not Supplied)

M6 x 16mm PoziMachine Screws to

Secure MDF Plaster EdgeTo Underside of Mechanism

(Supplied)

MDF Plaster Edge Trims (Supplied)

A

A

LOAD BEARING

53 15/16" min.1370 min.

Plasterboard /Gyproc Opening

66 11/16" min.1694 min.

Plasterboard /Gyproc

Opening

1 15/16"

50

1 1/4"

32

1 3/8"

35

CLFront

Back

OPTION 1 - FIXING TO WOODEN BEAMS

WWW.FUTUREAUTOMATION.NET

CHRS4-RES

TECHNICAL SHEETISSUE 007

SHEET 3

RESIDENTIAL CEILING HINGE RANGEWITH SWIVEL

UK +44 (0) 1438 833577 US +1 (603) 742 9181

SECTION B-BSCALE 1 : 3

Upto 12.5 [0.5"]Threaded Rod

Mounting Bracket Can BeRotated to Suit Installation

Suspended Ceiling StructureAcross Joint to MDF / Gyproc

Plasterboard / Gyproc

MDF Plaster Edge Trim

3 [0.1"] Plaster Skim

Tray Flush With Ceiling

50 9/16" ±1/4"

1285 ±6

64 3/16" + 3/16"0"

1630 + 50

3 1/2" min.

89 min.

Screws to secure MDF Plaster Edge to Ceiling Structure(Not Supplied)

M6 x 16mm PoziMachine Screws to

Secure MDF Plaster EdgeTo Underside of Mechanism

(Supplied)

MDF Plaster Edge Trims (Supplied)

LOAD BEARING4 x Threaded Rods to Secure Mechanism12.5 [0.5"] Max.

Timber Frame toSupport MDF PlasterEdge Trims

B

B

53 15/16" min.1370 min.

Plasterboard /Gyproc Opening

66 11/16" min.1694 min.

Plasterboard /Gyproc Opening

1 15/16"

50

1 1/4"

32

1 3/8"

35

CL

Front

Back

OPTION 2 - FIXING INTO SUSPENDED CEILING

WWW.FUTUREAUTOMATION.NET

CHRS4-RES

TECHNICAL SHEETISSUE 007

SHEET 4

RESIDENTIAL CEILING HINGE RANGEWITH SWIVEL

UK +44 (0) 1438 833577 US +1 (603) 742 9181

C

DETAIL CSCALE 1 : 3

28 No. OFFSS M6 x 16MMPOZI (SUPPLIED)

36 No.OFFMDF SCREW(NOT SUPPLIED)

7mm [1/4"]Shadow GapAround Tray

INSTALLATION PRECEDURE

1. MECHANISM INSTALLATION

2. MDF PLASTER TRIM INSTALLATION

3. PLASTERING

THE INSTALLATION PROCEDURE IS CARRIED OUTIN THE SAME WAY FOR OPTION 1 OR OPTION 2

WWW.FUTUREAUTOMATION.NET

CHRS4-RES

TECHNICAL SHEETISSUE 007

SHEET 5

RESIDENTIAL CEILING HINGE RANGEWITH SWIVEL

UK +44 (0) 1438 833577 US +1 (603) 742 9181

62"

1575

39 3/16"

995

D

63 15/16"1624 Overall Mechanism Width Inc. Mount Brackets

58 13/16"1494 Mechanism Width

8 1/4"210

Mechanism Height FromUnderside of Ceiling

46 5/8"1185 Overall Mechanism Length

1/2"12

7/8"23

0" 0

1

5/8"

41

2

9/16

"65

0"0

1 3/16"

30

1 3/4"

45

2 3/4"

70

3 3/4"

95

4 3/4"120

5 11/16"

145

DETAIL DSCALE 1 : 3

1 7/8"

47

MECHANISM DIMENSIONS - CLOSED

FIXING DETAILMechanism mounted on M12 [0.5] Studdingor fixed to underside of the ceiling joiststructure, both using the mounting bracketsinstalled on mechanism as standard

WWW.FUTUREAUTOMATION.NET

CHRS4-RES

TECHNICAL SHEETISSUE 007

SHEET 6

RESIDENTIAL CEILING HINGE RANGEWITH SWIVEL

UK +44 (0) 1438 833577 US +1 (603) 742 9181

44 1/2" max.1130 max.

Screen Width

26 3/4" max.680 max.

Screen Height

35"889

2 3/8"61

Swivel ClearanceFrom Underside

of Ceiling

8 3/4"222

14 7/8"379

7 7/8"200

11 13/16"

300

15 3/4"

400

17 1/16" max.

434 max.

3 15/16"

100 3 3/8"

85

Mount heightadjustable to suitwide variety ofscreen mountinglocations

MECHANISM DIMENSIONS - OPEN

Maximum VESA 400 x 400 supplied as standard

Custom Mount Options available on request

OPEN AND ROTATED

WWW.FUTUREAUTOMATION.NET

CHRS4-RES

TECHNICAL SHEETISSUE 007

SHEET 7

RESIDENTIAL CEILING HINGE RANGEWITH SWIVEL

UK +44 (0) 1438 833577 US +1 (603) 742 9181

Cable Routing

Cables for the screen can be routed in from both sides, allowing for power and signalcables to be separated when entering the mechanism.

The opening on both sides is MIN. 32mm [1.3"] in diameter allowing for multiple cables to be routed to the screen.

A power outlet mounting plate is supplied in the right hand gearbox allowing for UK and US power outlets to be wired directly into the mechanism.

Ensure Cables can be routedto / through ceiling joist / ceiling

structure at these points into mechanism.

Mechanism control system housed internally on this side.Accessible from removable internal access hatch.

2 No. US J-Box

UK 2G MainsPlasterboard

Back Box

VIEWING SIDE

2 3/8"

60

1 1/4"31.8

2 3/8"61

7 1/16"

180

16 1/8"

410

Ensure there are no obstructions around

the power outlet mounting plate, between the mechanism

and the mounting joist / ceiling structure

(Dimensions shown from rear of mechanismand underside of ceiling finish)

CEILING PREPARATION

AV Signal Cables / Mechanism Control Cables

Power Cable for Mechanism and AV

WWW.FUTUREAUTOMATION.NET

CHRS4-RES

TECHNICAL SHEETISSUE 007

SHEET 8

RESIDENTIAL CEILING HINGE RANGEWITH SWIVEL

UK +44 (0) 1438 833577 US +1 (603) 742 9181