MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,682,666; 7,634,976; 5,660,165; 5,954,492; 6,056,542; 6,935,280; 5,372,185; 5,485,879; 5,574,822; 7,971,560; 7,992,526; 6,684,821; 7,334,419; 7,866,168; 7,270,087; 7,007,748; 5,596,952; 6,142,216; 7,699,026; 5,341,770; 7,337,517; 7,665,211; 7,665,210; 7,063,132; 7,063,133; 7,559,293; 7,900,589; 5,943,984; 8,082,888; 5,988,117; 7,621,238; 7,650,859; 5,761,379; 7,409,925; 5,277,171; 8,146,772; 7,458,341; 2,262,174. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 2,314,845; 2,504,824; 2,108,186; 2,143,031; 2,409,271; 2,548,958; 2,112,515; 2,476,685; 2,239,007; 2,092,105; 2,107,012. Defender Safety System ® , ScreenLok ® , Vitraglas ® and Hydrojet ® are registered trademarks of Bradford White ® Corporation. Residential Atmospheric Vent Gas Water Heater 6 or 10-Year Limited Tank Warranties / 6 or 10- Year Limited Warranty on Component Parts. For more information on warranty, please visit www.bradfordwhite.com For products installed in USA, Canada, and Puerto Rico. Some states do not allow limitations on warranties. See complete copy of the warranty included with the heater. C1101-E-0220 The Atmospheric Vent FVIR Defender Safety System ® Models Feature: White Rodgers Electronic Control Exclusive to Bradford White—Intelligent gas control with proven millivolt powered technology and built-in piezo igniter. A thermopile converts heat energy into electrical energy to operate the gas valve and microprocessor. Requires no external power. -- Performance Enhancing Proprietary Algorithms. -- Advanced Temperature Control System—Microprocessor constantly monitors and controls burner operation to maintain consistent and accurate water temperature levels. -- Intelligent Diagnostics—An exclusive green LED light prompts the installer during start-up and provides five different diagnostic codes to assist in troubleshooting. -- Pilot On Indication—Flashing green LED provides positive indication that pilot is on. -- Durable Copper Thermowell and Brass Shank. Advanced ScreenLok ® Technology Flame Arrestor Design—Flame arrestor is designed to prevent ignition of flammable vapor outside of the water heater. Resettable Thermal Switch—Proven and reliable bimetallic switch prevents burner and pilot operation in case of ongoing flammable vapors burning inside of the combustion chamber or restricted air flow. Maintenance-Free—No regular cleaning of air inlet openings or flame arrestor is required under normal conditions. Sight Window—Offers a view into the combustion chamber to observe the operation of the pilot and burner. Factory-Installed Hydrojet ® Total Performance System—Sediment reducing device that also increases first hour rating of hot water while minimizing temperature build-up in tank. Vitraglas ® Lining—An exclusively engineered enamel formula that provides superior tank protection from the highly corrosive effects of hot water. This formula (Vitraglas ® ) is fused to the steel surface by firing at a temperature of over 1600°F (871°C). Insulation System—Non-CFC foam covers the sides and top of the tank, reducing heat loss. This results in less energy consumption, improved efficiencies, and jacket rigidity. Pedestal Base. Water Connections—3⁄4" (19mm) NPT factory installed true dielectric fittings. Factory-Installed Heat Traps. Protective Magnesium Anode Rod. 3x4 “Snap Lock” Draft Diverter—Allows either 3" (76mm) or 4" (102mm) vent connections with inputs of 40,000 BTU/Hr. or less. Over 40,000 BTU/Hr. has the 4" (102mm) “Snap Lock” Draft Diverter. T&P Relief Valve—Installed. Low Restrictive Brass Drain Valve—Durable tamper proof design. NOx Emissions—Less than 40 ng/J. FEATURING: Photo is of RG240T6N

Residential Atmospheric Vent Gas Water Heater · Residential Atmospheric Vent Gas Water Heater ... thermopile converts heat energy into electrical energy to operate the gas valve

  • Upload
    others

  • View
    11

  • Download
    0

Embed Size (px)

Citation preview

MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,682,666; 7,634,976; 5,660,165; 5,954,492; 6,056,542; 6,935,280; 5,372,185; 5,485,879; 5,574,822; 7,971,560; 7,992,526; 6,684,821; 7,334,419; 7,866,168; 7,270,087; 7,007,748; 5,596,952; 6,142,216; 7,699,026; 5,341,770; 7,337,517; 7,665,211; 7,665,210; 7,063,132; 7,063,133; 7,559,293; 7,900,589; 5,943,984; 8,082,888; 5,988,117; 7,621,238; 7,650,859; 5,761,379; 7,409,925; 5,277,171; 8,146,772; 7,458,341; 2,262,174. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 2,314,845; 2,504,824; 2,108,186; 2,143,031; 2,409,271; 2,548,958; 2,112,515; 2,476,685; 2,239,007; 2,092,105; 2,107,012. Defender Safety System®, ScreenLok®, Vitraglas® and Hydrojet® are registered trademarks of Bradford White® Corporation.

Residential Atmospheric VentGas Water Heater

6 or 10-Year Limited Tank Warranties / 6 or 10- Year Limited Warranty on Component Parts.For more information on warranty, please visit www.bradfordwhite.comFor products installed in USA, Canada, and Puerto Rico. Some states do not allow limitations on warranties. See complete copy of the warranty included with the heater.

C1101-E-0220

The Atmospheric Vent FVIR Defender Safety System® Models Feature: � White Rodgers Electronic Control Exclusive to Bradford White—Intelligent

gas control with proven millivolt powered technology and built-in piezo igniter. A thermopile converts heat energy into electrical energy to operate the gas valve and microprocessor. Requires no external power.-- Performance Enhancing Proprietary Algorithms.-- Advanced Temperature Control System—Microprocessor constantly

monitors and controls burner operation to maintain consistent and accurate water temperature levels.

-- Intelligent Diagnostics—An exclusive green LED light prompts the installer during start-up and provides five different diagnostic codes to assist in troubleshooting.

-- Pilot On Indication—Flashing green LED provides positive indication that pilot is on.

-- Durable Copper Thermowell and Brass Shank.� Advanced ScreenLok® Technology Flame Arrestor Design—Flame arrestor

is designed to prevent ignition of flammable vapor outside of the water heater.� Resettable Thermal Switch—Proven and reliable bimetallic switch prevents

burner and pilot operation in case of ongoing flammable vapors burning inside of the combustion chamber or restricted air flow.

� Maintenance-Free—No regular cleaning of air inlet openings or flame arrestor is required under normal conditions.

� Sight Window—Offers a view into the combustion chamber to observe the operation of the pilot and burner.

� Factory-Installed Hydrojet® Total Performance System—Sediment reducing device that also increases first hour rating of hot water while minimizing temperature build-up in tank.

� Vitraglas® Lining—An exclusively engineered enamel formula that provides superior tank protection from the highly corrosive effects of hot water. This formula (Vitraglas®) is fused to the steel surface by firing at a temperature of over 1600°F (871°C).

� Insulation System—Non-CFC foam covers the sides and top of the tank, reducing heat loss. This results in less energy consumption, improved efficiencies, and jacket rigidity.

� Pedestal Base.� Water Connections—3⁄4" (19mm) NPT factory installed true dielectric fittings.� Factory-Installed Heat Traps.� Protective Magnesium Anode Rod.� 3x4 “Snap Lock” Draft Diverter—Allows either 3" (76mm) or 4" (102mm) vent

connections with inputs of 40,000 BTU/Hr. or less. Over 40,000 BTU/Hr. has the 4" (102mm) “Snap Lock” Draft Diverter.

� T&P Relief Valve—Installed. � Low Restrictive Brass Drain Valve—Durable tamper proof design.� NOx Emissions—Less than 40 ng/J.

FEATURING:

Photo is ofRG240T6N

©2020, Bradford White Corporation. All rights reserved.

For field service, contact your professional installer or local Bradford White sales representative.

Sales / Technical Support 1-866-690-0961 / 905-203-0600 www.bradfordwhite.com

NATURAL GAS AND LIQUID PROPANE GASAtmospheric Vent Models

ModelNumber

Approx.ShippingWeight

lbs.

AFloor toExhaustConn.

in.

BJacketDia.

in.

RG130T6N�

RG230T6N� RG230S6N RG140T6N� RG240T6N� RG240S6N� RG150T6N� RG250T6N� RG250L6N RG250S6N�

RG260T6N

59 3/4

59 3/4

49 1/4

615/16

60 1/8

519/16

60 1/8

60 1/8

519/16

60 1/8

60 3/4

106116113132134139148154170167192

1618201820222022242224

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

MWaterConn.NPTin.

ModelNumber

Approx.ShippingWeight

kg.

AFloor toExhaustConn.mm.

BJacketDia.

mm.

RG130T6N�

RG230T6N� RG230S6N RG140T6N� RG240T6N� RG240S6N� RG150T6N� RG250T6N� RG250L6N RG250S6N�

RG260T6N

15181518125115571527131015271527131015271543

4853516061636770777687

406457508457508559508559610559610

CVentSize

in.

3 or 43 or 43 or 43 or 43 or 43 or 43 or 43 or 43 or 4

43 or 4

CVentSize

mm.

76 or 10276 or 10276 or 10276 or 10276 or 10276 or 10276 or 10276 or 10276 or 102

10276 or 102

EFloor to

GasConn.

in.

1313131313131313131313

EFloor to

GasConn.mm.

330330330330330330330330330330330

14291429116214681438122114381438122114381453

FFloor toTop ofHeater

in.

FFloor toTop ofHeatermm.

56 1/4

56 1/4

45 3/4

57 13/16

56 5/8

48 1/16

56 5/8

56 5/8

48 1/16

56 5/8

573/16

14481448118115131457124014571457124014571492

GFloor toWaterConn.

in.

GFloor toWaterConn.mm.

5757

461/2

59 9/16

57 3/8

4813/16

57 3/8

57 3/8

4813/16

57 3/8

583/4

495546597546597648597648699648724

HDepth

in.

HDepth

mm.

191/2

211/2

231/2

211/2

231/2

251/2

231/2

251/2

271/2

251/2

281/2

203203203203203203203203203203203

JC/L ofWaterConn.

in.

JC/L ofWaterConn.mm.

88888888888

DFloor to

T&PConn.

in.

49 3/4

49 3/4

38 7/8

515/8

493/4

411/16

4915/16

4915/16

40 11/16

4915/16

501/2

DFloor to

T&PConn.mm.

12641264987

13111264104312681268103312681283

1919191919191919191919

MWaterConn.NPTmm.

1/2

1/2

1/2

1/2

1/2

1/2

1/2

1/2

1/2

1/2

1/2

SGas

Conn.Sizein.

1313131313131313131313

SGas

Conn.Sizemm.

ModelNumber

NominalGal.

Capacity

Recovery at90°F Rise*

RG130T6N�

RG230T6N� RG230S6N RG140T6N� RG240T6N� RG240S6N� RG150T6N� RG250T6N� RG250L6N RG250S6N�

RG260T6N

3030304040405050485060

2525253333334242404250

BTU/Hr.Input

U.S.Gal.

Imp.Gal.

27,00032,00030,00034,00040,00040,00034,00040,00040,00050,00040,000

U.S.GPH

2934323743433743435443

Imp.GPH

2428373136363136364536

LPU.S.GPH

2933323734413741415243

LPImp.GPH

2423273133343134344536

LPBTU/Hr.

Input

27,00031,00032,00034,00036,00035,00034,00035,00035,00048,00040,000

FirstHour

Rating(Gal.)

4660496475697581777581

UniformEnergy Factor

0.540.600.540.590.640.580.630.630.630.630.62

UniformEnergy Factor

0.540.600.540.590.640.580.630.630.630.63

ModelNumber

Liters

NominalLiter

Capacity

Recovery at50°C Rise*

RG130T6N�

RG230T6N� RG230S6N RG140T6N� RG240T6N� RG240S6N� RG150T6N� RG250T6N� RG250L6N RG250S6N�

RG260T6N

114114114151151151189189182189227

kWInput

7.99.48.8

10.011.711.710.011.711.714.611.7

LPkW

Input

7.99.17.6

10.010.511.110.010.511.114.111.7

FirstHour

Rating(Liters)

174227185242284261284307291284307

UniformEnergy Factor

0.540.600.540.590.640.580.630.630.630.630.62

Liters/Hour

110129121139163163139163163204163

LPLiters/Hour

110125121139129155139155155197163

Recovery efficiency ranging up to 80%

Residential Atmospheric Vent Gas Water Heater

General:All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All water connections are 3⁄4" NPT (19mm) on 8" (203mm) centers. All gas connections are 1⁄2" (13mm).All models design-certified by CSA International (formerly AGA/CGA), ANSI standard Z21.10.1 and peak performance rated.Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. Suitable for Water (Potable) Heating and Space Heating.Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance.

Propane models feature a Titanium Stainless Steel propane burner. For Propane (LP) models change suffix “N” to “X”. For 10 year models, change suffix from “6” to “10”.* Based on manufacturer’s rated recovery efficiency. Uniform Energy Factor and First Hour Rating is based on the latest AHRI directory listings.• Models feature optional top T&P location and must be specified when ordering. Note: RG230S6N and RG250L6N do not have top T&P option.

Printed in U.S.A.C1101-E-0220