RESIDENTIAL AIR HANDLERS AR SERIES

RESIDENTIAL AIR HANDLERS AR SERIES. AR Nomenclature

Embed Size (px)

Citation preview

Page 1: RESIDENTIAL AIR HANDLERS AR SERIES. AR Nomenclature

RESIDENTIALAIR HANDLERS

AR SERIES

Page 2: RESIDENTIAL AIR HANDLERS AR SERIES. AR Nomenclature

AR

Page 3: RESIDENTIAL AIR HANDLERS AR SERIES. AR Nomenclature

NomenclatureAR 18 1

60 - 5 TONS

30/32 - 2-1/2TONS

36 - 3 TONS

42 - 3-1/2 TONS

48/49 - = 4 TONS

SINGLE PHASEMULTI POSITION

COOLING CAPACITY

18 - 1-1/2 TONS

24 - 2 TONS

ELECTRIC

AIR HANDLER

Page 4: RESIDENTIAL AIR HANDLERS AR SERIES. AR Nomenclature

AR RESIDENTIAL

Page 5: RESIDENTIAL AIR HANDLERS AR SERIES. AR Nomenclature

AR Multi-positionelectric air handler

• Versatile up flow, right or left horizontal, and counter flow multi-position

• May be located in closet, utility room, attic, or basement

• Equipped with a check flow rater for Heat pump and Cooling Unit Operation

• Power supply entry at top

Page 6: RESIDENTIAL AIR HANDLERS AR SERIES. AR Nomenclature

Airflow Orientation

Downflow discharge

(with plastic vertical pan

only)

*Horizontal Right Discharge

Tube and Drain conn. front

Horizontal Left DischargeTube and Drain conn. front

*UpflowDischarge

Important:Remove the horizontal pan when unit is installed in unconditioned i.e. (Garage, Attic) application, or downflow applications, and install insulation kit on vertical (donut shape) drain pan. Insulation kits should be ordered as follows:DPI 18-30/20 (AR18-32)DPI 36-42/20 (AR36-42)DPI 48-61/20 (AR48-61)

Page 7: RESIDENTIAL AIR HANDLERS AR SERIES. AR Nomenclature

AR Air Handlers

• All air handlers use direct drive motors. Power supply is 208/230 Volts, 60 HZ, 1 Phase

• AR is designed for zero (0”) inch clearance, however, adequate access for service or replacement must be considered

Page 8: RESIDENTIAL AIR HANDLERS AR SERIES. AR Nomenclature

Refrigerant tubing

• Refrigerant tubing should be installed as to avoid undue stress.

• Suction tube should be insulated with a closed cell insulation and the seams sealed

Page 9: RESIDENTIAL AIR HANDLERS AR SERIES. AR Nomenclature

Condensate Removal

• AR air handlers employ a draw-through coil, therefore a trap must be installed in the drain lines.

• A “P” trap is required.• Precautions must be used not to

over tighten the adapter at the drain pan connection.

• A joint compound should be used to prevent leakage and act as a lubricant.

• All condensate drain lines and drain traps should be adequately insulated.

• The unit and the auxiliary drain pan must be adequately elevated to insure proper drainage.

Page 10: RESIDENTIAL AIR HANDLERS AR SERIES. AR Nomenclature

Condensate Removal

Page 11: RESIDENTIAL AIR HANDLERS AR SERIES. AR Nomenclature

Electrical connections

• Copper wire is recommended for all electrical connections.

• 24 Volt thermostat connections

• Goodman Cooling and Heating thermostat part number is CHT18-60.

• Goodman Heat Pump thermostat part number is HPT18-60.

Page 12: RESIDENTIAL AIR HANDLERS AR SERIES. AR Nomenclature

Electronic Controls Blower Fan Controls

Page 13: RESIDENTIAL AIR HANDLERS AR SERIES. AR Nomenclature

Goodman Part #: B1370735

Page 14: RESIDENTIAL AIR HANDLERS AR SERIES. AR Nomenclature

Operating Tolerances & Ranges

• +80 to -40 Degrees Celsius (+176 to -40 F)

• 5% to 95% R.H. Non-Condensing

• 18 to 30VAC Control Voltage

• Frequency - 60Hz/50Hz

• Approved to UL353

Page 15: RESIDENTIAL AIR HANDLERS AR SERIES. AR Nomenclature

Normal Operation• Blower On Delay

– “G” Input Energizes – Blower Motor energized after a 7 second delay

• Blower Off Delay– “G” Input De-energizes – 65 Second Delay before Blower Motor turns off.

• Field And Factory Speedup Test Mode– If “R” applied to “SPEEDUP” Terminal

• Both “G” Delay Timings On & Off are Immediate

– If “C” applied to SPEEDUP Terminal• Delay On Timing is 3 Seconds• Delay Off Timing is 5 Seconds

Page 16: RESIDENTIAL AIR HANDLERS AR SERIES. AR Nomenclature

Field Returns

• Handling Boards by Edges or Use ESD Ground Strap

• Boxes or Bags for Field Returns

• No Repeated Control Change-out

• Moisture Control in Board Area

• Return Tag Information

Page 17: RESIDENTIAL AIR HANDLERS AR SERIES. AR Nomenclature

Ground Check

• Meter set to Ohms or Resistance Setting• Place Meter from GROUND quick connect to

chassis ground• Reading should be near Zero ohms• Issue: GROUND Quick Connect Loose ;

causes board resetting when blower starts• Issue: Flame Sensing problems if improper

grounding in system

Page 18: RESIDENTIAL AIR HANDLERS AR SERIES. AR Nomenclature
Page 19: RESIDENTIAL AIR HANDLERS AR SERIES. AR Nomenclature

Low Voltage Wiring 10 KW and Below

Page 20: RESIDENTIAL AIR HANDLERS AR SERIES. AR Nomenclature

Low Voltage Wiring 15 KW and Above

Page 21: RESIDENTIAL AIR HANDLERS AR SERIES. AR Nomenclature

Low Voltage Wiring for Heat Pumps

10 KW and Below

Page 22: RESIDENTIAL AIR HANDLERS AR SERIES. AR Nomenclature

Low Voltage Wiring for Heat Pumps

15 KW and Above

Page 23: RESIDENTIAL AIR HANDLERS AR SERIES. AR Nomenclature

Orifice Change

• The restrictor (orifice) included in this unit should match the comparable capacity of the outdoor unit.

• The restrictor (orifice) should be replaced before any tubing connections are made.

• The capacity of the outdoor unit should never exceed the capacity of the indoor unit.

Page 24: RESIDENTIAL AIR HANDLERS AR SERIES. AR Nomenclature

ORIFICE CHANGE OUTS

Page 25: RESIDENTIAL AIR HANDLERS AR SERIES. AR Nomenclature

Thank you!

any questions?