REQUEST FOR PROPOSAL
BUILDING ASSET MANAGEMENT SYSTEM (WEB BASED)
RFP #16 (2016-11)
ADDENDUM # 1
This addendum shall be incorporated into, and form part of RFP #16 (2016-11) and take precedence over all
requirements of the previously issued bid documents including plans. This addendum must be signed by the
bidder (signing officer) in the appropriate space and must be attached to the Form for submission by the
bidder. This Addendum consists of one (1) page and the documents listed below.
1. Closing Date:
Original closed date - Wednesday, 2016-11-23 by 1200 hours (noon), local time
Revised closing date - Wednesday, 2016-11-30 by 1200 hours (noon), local time
2. Schedule of Events:
The original scheduled listed in section 7.0 has been replaced by the following revised schedule
of events
Pre-Award
Release of RFP 2016-11-07
Proponents’ Question Deadline 2016-11-14
Submission Due 2016-11-30
Interviews, if necessary Week of 2016-12-05
Notification of Award By the Toronto Zoo 2016-12-09
Post-Award
Commencement of Work 2016-12-12
Testing 2017-03-03
Final implementation and sign off 2017-03-31
3. QUESTION
Sample Assessment. Please provide sample reports of the assessment to show the data and how it’s
formatted. Please include the vendor who conducted the assessment.
ANSWER
Please see the attached sample report. The assessment and reports were completed by CCI Group
Inc.
4. QUESTION
Existing Capital Planning Solution. Is Toronto Zoo using an existing solution for Capital
Planning? If yes, which product is it?
ANSWER
No, the Toronto Zoo is not using an existing solution for Capital Planning
RFP #16 (2016-11) BUILDING ASSET MANAGEMENT SYSTEM (WEB BASED)
ADDENDUM #1
5. QUESTION
Copy of Appendix II – Fee Proposal Form. Please email the fee proposal form. I don’t believe its
included in the package.
ANSWER
Please find Appendix II attached to this addendum.
6. QUESTION
Budget. Is there an amount budgeted for this project?
ANSWER
The Toronto Zoo is not disclosing the budget for this project.
Receipt of the Addendum shall be acknowledged as part of your submission.
The Board of Management of the Toronto Zoo reserves the right to reject any or all Quotations or to accept
any quotation, should it deem such action to be in its interests.
If you have any queries regarding this matter, please contact Mr. Peter Vasilopoulos, Supervisor, Purchasing
& Supply, at 416-392-5916.
Yours truly,
Peter Vasilopoulos
Supervisor, Purchasing & Supply
I/we hereby acknowledge receipt of this addendum and make allowance in my bid.
Signed (Must be Signing Officer of Firm)
Name of Firm
Date:
END OF ADDENDUM 1
APPENDIX II- FEE PROPOSAL FORM
Proponent Name:
Total proposed
price for services Annual fee HST TOTAL
Web-based software provision
and services including initial set
up, testing , training and sign off
by the Toronto Zoo
Annual Maintenance/support fees
Annual License fees for four (4)
super and standard users
Annual License fees for five (5)
read only users
Data input, per single
entry/record
Other itemized services or
products which are additional or
optional, excluded from Total
Proposed price for services,
1.
2.
3.
We propose to employ sub-consultant organizations to deliver services for this project. The Consulting
Team consists of the following firms and key personnel.
Discipline Name of Firm Key Personnel
Building Name Asset ID Address Inspected By
Date of
Inspectio
n
Construction
Date
Major
Renovation
Dates
Lot Area
(acre)
Footprint
Area (sf)
Gross
Floor
Area (sf)
Roof
Area (sf)
Storeys
(#)
Basement
Levels
Overall
Conditio
n
Administrative Support Centre AD0000 CCI Group Inc 11-Aug-15 1974 1994 11500 34122 14560 2 YES Fair
Facility Name Administrative Support Centre Gross Floor Area (sf) 202000 Inspected by CCI Group Inc
Construction Year 1974 Footprint Area (sf) 11500 Date of Visit 11-Aug-15
Major Renovation Year 1994 Roof Area (sf) 14560 Overall Condition Fair
Storeys (#) 2
2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 Component Total
Substructure $ - $ - $ - $ 5 $ - $ - $ - $ - $ - $ - 5$
Shell $ - $ 6 $ 31 $ - $ 28 $ - $ - $ - $ - $ 11 75$
Interior $ - $ - $ - $ 10 $ 106 $ - $ - $ - $ - $ 27 143$
Services $ - $ 40 $ - $ 20 $ 300 $ - $ 18 $ - $ - $ 335 712$
Equipment & Furnishings $ - $ - $ - $ 18 $ - $ - $ - $ - $ - $ 10 28$
Special Construction &
Demolition $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - -$
Sitework $ 4 $ 5 $ - $ - $ 40 $ - $ 8,762 $ - $ 6 $ 26 8,843$
Total per Year 4$ 51$ 31$ 53$ 473$ -$ 8,780$ -$ 6$ 409$ 9,807$
ALL COSTS ,000s. ALL COSTS IN 2015 DOLLARS
Facility Overview
Site Summary: Asphalt paved parking lot and entrance drives are located on the north side of the site. The parking lot is drained to stormwater catch basins. A concrete unit
retaining wall separates the upper and lower parking areas. Pedestrian paving consists of unit pavers. The site is illuminated by light standards and wall mounted fixtures.
Building Description: The Toronto Zoo Administration building was constructed in 1974 and extensively renovated in 1993-1994. The building is attached to the Research and
Education Centre to the south and the Facilities Support building to the west. The Administration building consists of Change Room facilities for staff, offices, cafeteria, and
boardroom.
Building Envelope Summary: The exterior walls are clad with painted wood siding installed during the 1993-1994 renovation. Double glazed, aluminum framed windows, entry
doors, and skylights are installed. The sloped roofs are finished with metal panels. The flat roof section is finished with an inverted membrane.
Interior Finishes Summary: Interior finishes consist of concrete floor coating, terrazzo, rubber flooring, carpet, gypsum board, and lay-in ceiling tiles. Laminate cabinets and
countertops are installed. Interior finishes were typically installed in 1993-1994. Finishes are generally functional but dated.
Mechanical Summary: The building is heated hyrdonically. Boilers are located in the Facilities Support Building. Air handling units provided fresh are to the fancoil units located
throughout the building. The fancoil units provide heating and cooling with individual thermostats. Rooftop exhaust fans provide ventilation for the Washrooms and Change Rooms.
Hot water for domestic use is provided by units in the Facilities Support Building. Conventional flush valve water closets and urinals are installed.
Electrical Summary: The main electrical service is fed from the main Electrical Room in the Facilities Support Building to the Penthouse distribution panels. The 600-Volt service is
stepped down using a 150kVA transformer. T8 fluorescent and compact fluorescent light fixtures are installed throughout. Emergency power is provided by generators located on
the west side of the Vehicle Maintenance Garage.
Life Safety Summary: The building is sprinklered. A Simplex fire alarm control panel is installed. The system includes heat and smoke detectors, pull stations, and alarm bells.
Structural Summary: The basement is framed with poured concrete, including foundation walls, slab-on-grade, and concrete columns to support the first floor concrete slab. The
second floor and roof are steel framed.
$5.00 $75.20 $143 $712
$28 $-
$8,843
$-
$1,000
$2,000
$3,000
$4,000
$5,000
$6,000
$7,000
$8,000
$9,000
$10,000
Major Component
10 Year Cost Summary by Component
Substructure
Shell
Interior
Services
Equipment & Furnishings
Special Construction & Demolition
Sitework$5.00 $75.20 $143
$712
$28 $-
$8,843
$-
$1,000
$2,000
$3,000
$4,000
$5,000
$6,000
$7,000
$8,000
$9,000
$10,000
Major Component
10 Year Cost Summary by Component
Substructure
Shell
Interior
Services
Equipment & Furnishings
Special Construction & Demolition
Sitework
Name: Administrative Support Centre GFA (sf): 34122 Prepared by: CCI Group Inc
Constructed: 1974 Roof (sf): 14560 Date: 2015-08-11
Current Year: 2016
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
A SUBSTRUCTURES $ - $ - $ - $ 5 $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ -
A10 Foundations
A1010 Standard Foundations
AD0000 Wall Foundations Continuous Footings 100 1974 58 2073 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.075 lf Poured concrete strip footings, based on design drawings of newer
sections. No notable issues. No allowances made through the study
period.
AD0000 Wall Foundations Foundation Walls 100 1974 58 2073 Fair Building
Integrity
3-Not Yet
Critical
$ 5 $ 5 $ 5.000 LS 1 Foundation walls are poured concrete on concrete strip footings.
Foundations walls are in good condition where visible. Localized water
ingress was noted in the Telephone Room at the wall penetration. Allow
for short term repairs.
$ 5
A1020 Special Foundations
A1030 Slab-On-Grade
AD0000 Standard SOG Poured Concrete with
or without
reinforcement.
100 1974 58 2073 Good Building
Integrity
4-
Recomm
ended
$ 289 $ - $ 0.025 sf 11560 Concrete slab-on-grade is in good condition where exposed. Minor hairline
cracking was noted on floor coatings.
AD0000 Subdrainage Storm drainage tile. 45 1974 3 2018 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.030 lf Weeping tile systems are installed around the foundations. No adverse
conditions noted. It is assumed one repair has occurred and an allowance
is carried for repairs as needed, to coincide with foundation repairs.
$ -
A20 Basements $ -
A2010 Basement Excavation
A2020 Basement Walls
AD0000 Vertical Waterproofing Fluid Applied
Dampproofing
5 1974 -37 1978 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 8.000 LS Allow for future foundation repairs. Water entry to lower levels has
occurred in the past.
AD0000 Vertical Waterproofing Fluid Applied
Dampproofing
50 1974 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 170.000 LS Rubberized waterproofing at Athletic Centre foundation is in good
condition. Upper terminations were not well finished.
$ -
B SHELL $ - $ 6 $ 31 $ - $ 28 $ - $ - $ - $ - $ 11 $ - $ 46 $ - $ - $ 143 $ - $ - $ - $ - $ 575
B10 Superstructure $ -
B1010 Floors
AD0000 Floor Structural Frame Precast Concrete Core 100 1974 58 2073 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.075 sf Precast concrete core slabs supported on steel framing members are
used at the 2nd Floor level. HSS support columns are also used. No
issues noted and no allowances carried.
AD0000 Interior Structural Walls Concrete Block
Construction
100 1974 58 2073 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.018 sf Concrete block demising walls throughout interior areas are in good
condition. No adverse conditions noted. No allowances are made through
the study period.
AD0000 Floor Decks, Slabs and
Topping
Flat Slab, Reinforced
Concrete
100 1974 58 2073 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.029 sf Reinforced concrete floor framing including slab, support columns and
drop panels used for 2nd and 3rd Floor framing.
AD0000 Floor Decks, Slabs and
Topping
Wood Framing 100 1974 58 2073 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.029 sf Wood joists on steel beams and clay tile/masonry wall supports with
plaster ceiling and wall finishes. No allowances are carried.
AD0000 Floor Decks, Slabs and
Topping
Concrete Framing 100 1974 58 2073 Good Building
Integrity
1-
Currently
Critical
$ 335 $ - $ 0.029 sf 11560 First floor is framed with poured concrete, including concrete columns and
floor slab with dropped panels. The elevator core is poured concrete. No
issues were noted.
AD0000 Floor Decks, Slabs and
Topping
Composite Metal Deck 100 1974 58 2073 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.035 sf The floors are composite metal deck supported by steel joists and
columns. No issues reported. No allowances are carried throughout he
study period.
AD0000 Floor Structural Frame 100 1974 58 2073 Good Building
Integrity
1-
Currently
Critical
$ 667 $ - $ 0.029 lf 23000 Second floor consists of metal deck with concrete topping supported by
open web steel joists (OWSJ), steel wide-flange beams, and steel
columns.
ALL COSTS IN 000' (2015) DOLLARS
Page 1 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Interior Structural Walls Concrete Block
Construction
100 1974 58 2073 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.018 sf Concrete block demising walls throughout interior areas are in good
condition. No adverse conditions noted. Replacement costs are not
anticipated during this study period.
AD0000 Floor Decks, Slabs and
Topping
Composite Metal Deck 100 1974 58 2073 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 35.000 sf The basement, first (mezzanine), and second floor levels are framed with
conventional steel members. A combination of composite metal deck,
reinforced concrete, and concrete joists exist throughout the building.
Replacement costs are anticipated during this study period.
AD0000 Floor Structural Frame Floor Girders and
Beams
100 1974 58 2073 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 240.000 lf Steel I beams support open web steel joists and composite metal deck.
No adverse conditions noted. Replacement costs are not anticipated
during this study period.
AD0000 Interior Structural Walls Concrete Block
Construction
100 1974 58 2073 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 18.000 sf Concrete block demising walls throughout interior areas are in good
condition. No adverse conditions noted with the exception of the block
back-up walls of the Junior School Gymnasium where extensive vertical
cracking was noted. Allow to provide crack monitors in the short term to
determine if cracks are actively moving. Allow to rout and seal the joints
with flexible sealants. Replacement costs are not anticipated during this
AD0000 Interior Structural Walls Concrete Construction 100 1974 58 2073 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 18.000 sf Reinforced concrete construction of pool basin covered under other Item.
Replacement costs are not anticipated in this study.
AD0000 Floor Fireproofing Sprayed 40 1974 10 2025 Fair Building
Integrity
1-
Currently
Critical
$ 46 $ 46 $ 0.004 sf 11560 Sprayed fireproofing applied to underside of steel beams and decking is in
good condition.
$ 46
AD0000 Wall Firestopping 30 1974 -12 2003 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.000 LS Firestopping at wall pipe penetrations is in good condition. Firestopping at
top of block walls at Level 300 areas could be better; allow for repairs.
B1020 Roof Construction
AD0000 Roof Structural Frame Girders and Beams 100 1974 58 2073 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 13.000 sf Steel beams, columns, open web steel joists and long span tapered joists
and metal roof deck are installed for the main roof framing. All systems,
where exposed are in good condition. No allowances carried.
AD0000 Roof Structural Frame Roof Trusses 100 1974 58 2073 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.000 sf Assembly Hall has solid wood framed trusses with tongue-and-groove roof
decking are in good condition with no damage observed. Replacement
cost is not carried.
AD0000 Roof Structural Frame Steel 100 1974 58 2073 Good Building
Integrity
1-
Currently
Critical
$ 231 $ - $ 0.020 sf 11560 Flat and sloped roof sections are steel framed. Metal decking is installed.
AD0000 Roof Structural Frame Steel 100 1974 58 2073 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 sf Tongue=and=groove wood roof deck on steel beams and columns at west
foyer.
AD0000 Floor Structural Frame Floor Girders and
Beams
100 1974 58 2073 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 240.000 lf Concrete roof framing at mezzanine level is in good condition.
AD0000 Roof Structural Frame Roof Trusses 100 1974 58 2073 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.000 sf 72' span and 4' deep steel trusses in the Pool are in good condition. No
allowances carried over the study period.
AD0000 Roof Structural Frame Roof Trusses 100 1974 58 2073 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.000 sf Long span steel trusses in the Gym are in good condition. No allowances
carried over the study period.
B20 Exterior Closure $ -
B2010 Exterior Walls
AD0000 Wall Construction Masonry Brick Wall with
Block Back-up
50 1974 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.025 sf Jumbo sized clay brick veneer walls are in good condition. The assembly
is installed as a veneer system complete with weepholes and 1" air space,
insulation and block back-up. Algae/moss growth was evident in localized
areas. Allow for longer term repairs based on 10% of total area.
$ -
Page 2 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Wall Construction Wood Clad Exterior
Walls
50 1994 28 2043 Good Building
Integrity
4-
Recomm
ended
$ 195 $ - $ 0.030 sf 6500 Exterior walls are clad with diagonally and horizontally installed ship lap
wood siding. The cladding has been painted recently.
AD0000 Wall Construction Precast Concrete 40 1974 -2 2013 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.025 sf Precast concrete wall panels are installed at the clock tower and accent
areas on the south elevation. The panels are in good condition with no
damage. Allow for longer term repairs and cleaning only.
AD0000 Parapets 20 1974 -22 1993 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.023 lf Caulking at parapet cap stones is in poor condition. Allow for
repairs/replacement in short term.
AD0000 Other Caulking 18 1974 -24 1991 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.009 lf Sealants at windows, doors and wall control joints are in good condition
throughout. Allow for replacement in the longer term. Localized failure at
window sills and chiller pipe penetrations was noted; allow for repairs in
short term.
AD0000 Other Exterior Walls Thermography 6 1974 -36 1979 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Allowance for exterior wall thermography in short term.
AD0000 Outside Wall Exterior
Skin
Stone Masonry with
Block Back-up
75 1974 33 2048 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.035 sf Solid stone masonry with a block backup wall throughout the original
building is in fair condition. Larger sections of the cladding is covered by
vegetation. Significant staining is visible throughout, and indicating
leaching of iron impurities through stones. Major repair (20% of total) is
allocated for the longer term with intermittent repairs in short term.
AD0000 Outside Wall Exterior
Skin
Bridge 50 1974 8 2023 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 LS Bridge repairs at main entrance are required. Concrete pad and trench
drain are in good condition. No structural issues as previously reported by
others.
$ -
AD0000 Outside Wall Exterior
Skin
Bridge 50 1974 8 2023 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 LS Bridge repairs at main entrance are required. Concrete pad and trench
drain are in good condition. No structural issues as previously reported by
others.
$ -
AD0000 Outside Wall Exterior
Skin
Exterior Insulation Finish
System (EIFS) Wall
System
20 1974 -22 1993 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.012 sf A newer EIFS (stucco)cladding has been installed on the east elevation
which have a life expectancy of 40+ years if maintained. The durability of
this system depends on the integrity of the joints. Annual inspection and
localized repair is recommended. The finish will require refurbishment
every 20 years which has been included in this study period.
AD0000 Outside Wall Exterior
Skin
Stone Masonry with
Block Back-up
75 1974 33 2048 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.035 sf Masonry with a block backup wall is located on the west elevation and is
in fair condition. Annual inspection and localized repairs of stone flaking,
delamination and cracks to prevent damage caused by moisture
penetration. Repair costs are included every 5 years, as needed.
AD0000 Wall Construction Brick Masonry with
Block Back-up
75 1974 33 2048 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.025 sf The 1961 building forming part of the Athletic Building has masonry brick
tied to interior concrete block forming a solid masonry wall and is in fair
condition. The 2006 addition encloses the north and east walls, the south
and west walls remain exposed. Re-pointing of the mortar joints and
replacement of any damaged bricks is carried every 10 years, as needed.
Routine inspection and localized repairs are recommended. 30%
allocation made.
AD0000 Outside Wall Exterior
Skin
Precast Concrete
Panels (stucco finish)
with Insulation and
Concrete Block Back-
up
20 1974 -22 1993 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.012 sf 5" precast concrete panels on 2" insulation and 4" concrete block backup
wall are in good condition. The panels have been recoated with an acrylic
stucco to match the EIFS exterior of the 1999 addition. Split sealant
between panels was observed (separate line item). An allowance is
carried for refinishing of the stucco coating every 20 years, as needed.
Includes copper downspouts to below grade.
AD0000 Outside Wall Exterior
Skin
Stone Veneer with
Block Back-up
75 1974 33 2048 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.025 sf Sections of stone veneer is located on all elevations and are in good
condition. There is an insulating cavity between the stone and interior
block wall. Weep holes are provided over windows, doors, and at the
bottom of walls. An allowance is carried for re-pointing the mortar joints at
25 years, every 2 years at 20% of area.
AD0000 Outside Wall Exterior
Skin
Exterior Insulation Finish
System (EIFS) Wall
System
20 1974 -22 1993 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.012 sf EIFS (stucco) cladding is located at the north elevation. The durability of
this system depends on the integrity of the joints. The finish will require
refurbishment every 20 years. Allow for recoating and repairs in the longer
term. Annual inspection and localized repairs is recommended.
Replacement costs are not anticipated within this study period.
AD0000 Outside Wall Exterior
Skin
Exterior Insulation Finish
System (EIFS) Wall
System
20 1974 -22 1993 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.012 sf EIFS (stucco) cladding is located at the north elevation. The durability of
this system depends on the integrity of the joints. The finish will require
refurbishment every 20 years. Allow for recoating and repairs in the longer
term. Annual inspection and localized repairs is recommended. Major
replacement costs are not anticipated within this study period.
AD0000 Outside Wall Exterior
Skin
Exterior Insulation Finish
System (EIFS) Wall
System
20 1974 -22 1993 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.012 sf EIFS (stucco) cladding is located at the east building (Pool). The durability
of this system depends on the integrity of the joints. The finish will require
refurbishment every 20 years. Allow for recoating and repairs in the longer
term. Replacement costs are not anticipated within this study period.
Page 3 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Outside Wall Exterior
Skin
Prefinished Insulated
Aluminum Panels
45 1974 3 2018 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.045 sf Prefinished insulated aluminum panel accents throughout the building.
Refurbishment of the aluminum panels will be required every 20 years
which falls below the threshold of this study. Replacement costs are not
anticipated within this study period.
$ -
AD0000 Outside Wall Exterior
Skin
Copper Cladding 75 1974 33 2048 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.037 sf 32 oz. copper sheeting over plywood sheathing is located at the west
entrance and Archive Addition. Surfaces are in good condition. Routine
inspection and localized repairs is recommended as needed.
Replacement costs are not anticipated during this study period.
AD0000 Outside Wall Exterior
Skin
Copper Cladding 75 1974 33 2048 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.000 LS Copper cladding at parapet is in good condition with minor damage.
AD0000 Outside Wall Exterior
Skin
Stone Veneer with
Block Back-up
75 1974 33 2048 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.025 sf Sections of stone veneer is located on all elevations and in good
condition. There is an insulating cavity between the stone and interior
block wall. Weep holes are provided over windows, doors, and at the
bottom of walls. Annual inspection and localized repairs is recommended,
as needed. Re-pointing should commence at 30 years. No allowances are
carried within this study period. Allow for re-pointing 20% in 2036.
AD0000 Other Exterior Walls Caulking 20 1994 1 2016 Poor Building
Integrity
2-
Potenially
Critical
$ 11 $ 11 $ 0.012 lf 900 Sealants at windows, skylight, and doors are failing. Cracking was noted
throughout. Allow for short term replacement to maintain a watertight
envelope.
$ 11
AD0000 Other Exterior Walls Caulking 20 1974 -22 1993 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.012 lf Sealants at windows, doors, flashing, control joints of EIFS and at the
junction of the different materials are in fair condition. The EIFS joints are
not well tooled and failure has occurred. Allow for replacement in the short
term,
AD0000 Other Exterior Walls Caulking 20 1974 -22 1993 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.012 lf Sealants at windows, doors, base flashing and curtainwall are in fair
condition with localized failure throughout. Allow for repairs in the long
term as full replacement is imminent.
AD0000 Other Exterior Walls Caulking 20 1974 -22 1993 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.012 lf Sealants at windows, doors, base flashing, curtainwall, control joints, and
at the junction of different materials are in fair condition with localized
failure throughout. Allow for repairs in the short term as full replacement is
imminent.
B2020 Exterior Windows
AD0000 Curtain Wall 30 1974 -12 2003 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.083 sf Aluminum framed curtainwall system on the north elevation is in fair
condition.
AD0000 Curtain Wall 30 1974 -12 2003 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 65.000 sf Thermally-broken aluminum framed double-glazed sealed window units
are in good condition. Allow for replacement in longer term. Includes
southeast foyer entrance.
AD0000 Historical Windows 30 1974 -12 2003 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 290.000 LS Lead framed windows with the Brenda Robson Hall and Ellen Knox
Library were restored between 2012 and 2014. Six of the windows do not
match the original windows. Routine refurbishment is needed, and major
restoration every 30 years. Allow also for refurbishment of the northwest
stair to the Brenda Robson Hall and the Residence Head Apartment
windows in the future.
AD0000 Skylight 40 1994 18 2033 Good Building
Integrity
4-
Recomm
ended
$ 15 $ 15 $ 15.000 LS 1 Aluminum framed, double glazed skylights are installed above the central
Corridor. The skylights are in good condition but sealants are failing.
$ 15
AD0000 Standard Windows Aluminum Type 35 1994 13 2028 Good Building
Integrity
4-
Recomm
ended
$ 143 $ 384 $ 0.065 sf 2200 Aluminum framed, double glazed windows are installed throughout. $ 143
AD0000 Standard Windows 25 1974 -17 1998 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.065 sf Thermally-broken aluminum framed double-glazed sealed insulating
window units were replaced between 2008 and 2013 in the 1926/1961
wings. Includes fixed and casement styles. No issues have been
reported, the windows are in good condition. Allow for replacement in
longer term.
AD0000 Standard Windows -
Dormers
25 1974 -17 1998 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.065 sf Dormer windows: thermally-broken vinyl framed double-glazed sealed
insulating window units are in good condition. The exteriors were also
refinished with aluminum siding and metal roofs. Allow for replacement in
longer term.
AD0000 Weatherstripping 15 1974 -27 1988 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Window and door weatherstripping is in fair condition.
B2030 Exterior Doors
Page 4 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Exterior Entrance Doors Aluminum, Double 30 1974 -12 2003 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 7.000 # Aluminum, double glazed, double doors at main west (#4) entrance is in
good condition. Includes automatic operators.
AD0000 Exterior Entrance Doors Aluminum, Single 25 1994 3 2018 Fair Building
Integrity
4-
Recomm
ended
$ 20 $ 20 $ 10.000 # 2 North entrances are single, aluminum framed, double glazed doors with
sidelights.
$ 20
AD0000 Exterior Entrance Doors Aluminum, Single 40 1974 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 # Aluminum framed by Kawneer, full glazed doors at north quadrant are in
fair condition. Replace with curtainwall system.
AD0000 Exterior Entrance Doors Metal Clad, Double 25 1974 -17 1998 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.000 # Metal/wood framed doors with glazing, located at east foyer and north
central stair 2, are in good condition.
AD0000 Exterior Entrance Doors Metal, Single 30 1994 8 2023 Good Building
Integrity
4-
Recomm
ended
$ 3 $ 4 $ 3.000 # 1 Metal clad exit door on the south elevation. $ 1 $ 3
AD0000 Exterior Entrance Doors Wood Entrance, Double 30 1974 -12 2003 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 8.000 # Main entrance (#1) is fitted with double wood doors with single glazing.
The doors are in fair condition with localized wear. Allow to refurbish in
short term and replace/major refurbish in longer term.
AD0000 Exterior Service Doors Metal Clad, Double 30 1974 -12 2003 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.000 # Metal clad doors at west exit (#2) at Bridge are in good condition.
AD0000 Exterior Service Doors Metal, Single 30 1974 -12 2003 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Metal clad single door at service garage (#11) is in good condition.
AD0000 Utility Doors Overhead Roll-up Type 20 1974 -22 1993 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.000 # Older overhead door at the Service Garage. Allow to update in the short
term including overhead door motor and control.
B30 Roofing $ -
B3010 Roof Coverings
AD0000 Flashing and Sheet
metal
25 1974 -17 1996 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Prefinished metal flashing and counter flashing are in good condition.
Allow for future replacement with the roofing membrane component.
AD0000 Manufactured Roofing Accessories 30 1974 -12 2003 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.500 LS Older tubular steel flag pole at Tower roof is in fair condition.
AD0000 Manufactured Roofing Flat, BUR 20 1974 -22 1993 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.012 sf Flat 4-ply built-up asphalt felt membrane system with perimeter sheet
metal flashing. The drainage is adequate via central drains. No issues
reported. Allow for routine annual maintenance. Replacement cost carried
for the flat roofs within the next 5 years.
AD0000 Manufactured Roofing Flat, concrete 30 1974 -12 2003 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.017 sf The roof of the Grade 12 Common Locker Room is protected by a
waterproofing membrane and concrete cover. Allow to re-coat in short
term.
AD0000 Manufactured Roofing Flat, Inverted 30 1974 -12 2003 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.022 sf Inverted Roof Membrane System (IRMA) includes river washed stone
ballast and precast pavers, filter fabric, insulation, modified bitumen roof
membrane on sheathing board over steel deck. Drainage is adequate via
central drains. Routine annual maintenance is recommended. Replace in
long term, costs included in study.
AD0000 Manufactured Roofing Sloped, Metal 40 1994 18 2033 Good Building
Integrity
4-
Recomm
ended
$ 20 $ 560 $ 580 $ 0.040 sf 14000 Sloped roofs are finished with standing seam metal roofing. Snow guards
are installed. Minor wear and surface corrosion was noted. Allow for short
term refurbishment.
$ 20 $ 560
AD0000 Manufactured Roofing Sloped, PVC 35 1974 -7 2008 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.015 sf Single layer, PVC membrane over the Theatre Roof is in good condition.
The drawings indicate that the roof is installed on 3" rigid insulation,
vapour barrier on cement board.
Page 5 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Manufactured Roofing Sloped, shingle 18 1974 -24 1991 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.006 sf Asphalt shingles are located on the sloped roofs of the North Wing
(Resource Centre). Significant curling and deterioration was observed.
Drainage is via aluminum eavestrough and leaders to the ground.
Replacement cost is carried for the asphalt shingles in year 1.
AD0000 Membrane Roofing Flat Conventional 20 1974 -22 1993 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.019 sf The canopy roof is protected by a conventionally applied modified bitumen
membrane. The membrane is wearing well.
AD0000 Membrane Roofing Flat Inverted 30 1994 8 2023 Good Building
Integrity
1-
Currently
Critical
$ 5 $ 8 $ 13 $ 0.015 sf 560 Flat roof is finished with an inverted membrane with rigid insulation, scrim
sheet, and river rock ballast. Past water ingress was noted in the second
floor Storage Room below the inverted roof. Allow for further investigation
and repairs.
$ 5 $ 8
AD0000 Other Trellis 25 1974 -17 1998 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 7.500 LS Wood trellis on steel beam supports is in good condition. Allow for
complete refurbishment in longer term.
AD0000 Roof Specialties and
Accessories
Eavestroughs and
Downspouts
25 1994 3 2018 Good Building
Integrity
4-
Recomm
ended
$ 8 $ 8 $ 7.500 LS 1 Eavestroughs and downspouts are installed on the north and south
elevations. Downspouts continue below grade to the weeping tile system.
$ 8
AD0000 Roof Specialties and
Accessories
Soffits 35 1974 -7 2008 Fair Appearan
ce
4-
Recomm
ended
$ 1 $ - $ 1.000 LS 1 Transite soffit panels are installed at the north entrances. Allow to
refurbish.
C INTERIOR $ - $ - $ - $ 10 $ 106 $ - $ - $ - $ - $ 27 $ - $ 4 $ - $ - $ - $ - $ - $ - $ - $ -
C10 Interior Construction $ -
C1010 Partitions
AD0000 Gymnasium Divider 25 1974 -17 1998 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 12.000 LS Gym divider is vinyl clad gypsum board. The partition is in good condition.
AD0000 Interior Fixed Partitions Concrete Block Type 45 1974 29 2044 Good Building
Integrity
4-
Recomm
ended
$ 16 $ - $ 0.020 sf 800 Partitions in the basement are concrete block. Glazed concrete block is
installed at wet areas in the Change Rooms. Concrete block partitions are
in good condition overall. Localized cracking was noted at the entrance to
the Women's Change Room.
AD0000 Interior Fixed Partitions Gypsum Board 45 1974 3 2018 Fair Appearan
ce
4-
Recomm
ended
$ 5 $ 5 $ 5.000 LS 1 First and second floor partitions are steel framed and finished with gypsum
wall board. Minor wear and damage was noted in high traffic areas. An
allowance has been made for repairs and installation of wall coverings and
corner guards.
$ 5
AD0000 Interior Windows 40 1974 24 2039 Good Building
Integrity
1-
Currently
Critical
$ 50 $ - $ 0.100 sf 500 Steel framed glazing is installed at the basement stair, Cafeteria, and
Reception. Glazing in the basement is Georgian Wire Glass (GWG).
AD0000 Interior Windows 40 1974 -2 2013 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 LS Original wood framed windows facing interior light well are in fair condition.
Allow to refinish in longer term.
AD0000 Interior Windows 40 1974 -2 2013 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.100 sf Interior glazing at mezzanine is frameless and in good condition.
Replacement not anticipated.
AD0000 Operable and Folding
Panel
Accordion Type 25 1974 -17 1998 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.500 # Vinyl clad gypsum hardboard accordion partitions are installed within the
Classrooms. Includes control devices and tracks. Allow for long term
replacement.
AD0000 Toilet Partitions 20 1994 8 2023 Fair Appearan
ce
4-
Recomm
ended
$ 24 $ 24 $ 1.000 # 24 Washrooms and Change Rooms are equipped with laminate toilet and
shower stall partitions. The partitions are dated but functional.
$ 24
C1020 Interior Doors
AD0000 Fire Doors Hollow Metal Type 40 1974 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 1.400 # The 4th Floor Bedrooms are equipped with hollow wood type doors and
metal knock-up frames. The components are UL rated with standard knob
type pass sets and no self-closers.
AD0000 Interior Entrance Doors Aluminum Type 30 1974 -12 2003 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.400 # Aluminum framed, full glazed panel door systems are in good condition.
Includes single and double swing type.
Page 6 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Interior Swing Doors Metal Clad 25 1974 -17 1998 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 1.700 # Single leaf metal doors to Tower Level 500 stairwell are in good condition.
Replacement anticipated in longer term.
AD0000 Interior Swing Doors Metal Doors 25 1974 -17 1998 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.900 # Older metal doors in basement and sub-basement areas are in fair
condition. Newer metal clad doors are also installed at service doors.
AD0000 Interior Swing Doors Solid Wood 25 1974 -17 1998 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.300 # Single leaf wood doors at Tower Level 500 are in good condition.
Replacement not anticipated; refurbish only.
AD0000 Interior Swing Doors Wood Laminate Type 30 1974 -12 2003 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.400 # Wood laminate doors, in metal frames, are in good condition at the Pool
and Gym area.
AD0000 Interior Swing Doors 25 1994 3 2018 Fair Appearan
ce
4-
Recomm
ended
$ 100 $ 100 $ 1.000 # 100 Fire rated metal doors in metal frames are installed at stairwells and
service rooms. Laminate doors with stainless steel kickplates are installed
at common areas. Lever type hardware is installed.
$ 100
AD0000 Large Interior Doors Rolling Metal Door 50 1974 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 # Rolling metal door at Boiler Room is in good condition. Could possibly
contain asbestos within core. Allow for longer term replacement.
$ -
AD0000 Other Interior Doors Hardware 15 1974 -27 1988 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 115.000 LS The facility has no master keying system. A key audit and installation
project is slated for 2016.
AD0000 Other Interior Doors Hardware 25 1974 -17 1998 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 LS Sargent lever type door latches are in good condition.
C1030 Fittings
AD0000 Change room Cubbies
and Bench
Wood 25 1994 10 2025 Fair Appearan
ce
4-
Recomm
ended
$ 4 $ 4 $ 4.000 LS 1 Steel framed benches with wood slat seating are installed in the Change
Rooms. Minor wear was noted.
$ 4
AD0000 Fabricated
Compartments and
Cubicles
Washroom / Shower
Stall
20 1974 -22 1993 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 1.000 # Metal washroom and shower stalls are in good condition. Costs for
replacement included for under Interior Finishes Section.
AD0000 Fabricated
Compartments and
Cubicles
Washroom Stall 20 1974 -22 1993 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 1.200 # Metal washroom stalls are in good condition. Replace stalls in the longer
term.
AD0000 Lockers Steel 25 1994 3 2018 Fair Functiona
lity
4-
Recomm
ended
$ 1 $ 1 $ 1.000 LS 1 Full and half height steel lockers are installed in the Change Rooms.
Locker doors are perforated for venting.
$ 1
AD0000 Lockers Steel Type 25 1974 -17 1998 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.500 LS Steel, baked enamel finish, full height, lockers are in fair condition.
AD0000 Storage Shelves Wood 25 1974 -17 1998 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Wood framed laminate lockers, with open shelf top and bottom, are in
good condition.
C20 Stairs $ -
C2010 Stair Construction
AD0000 Access Ladder 40 1974 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 LS Steel access ladder and plywood access hatch at top of Tower stairwell
require protection.
AD0000 Concrete Stairs 100 1974 58 2073 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ - # 0 Central basement stair is concrete and finished with rubber flooring.
Textured strips are installed on nosings. Wall mounted tubular steel
handrails are installed. Finishes are included with flooring.
Page 7 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Concrete Stairs 75 1974 33 2048 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 # Level 100: Southwest exit stair #18 has no handrails and landing is short.
AD0000 Concrete Stairs 75 1974 33 2048 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 # Level 100: Northwest interior terrazzo stair has one discontinuous
handrail. Allow to adjust/add handrails.
AD0000 Concrete Stairs 75 1974 33 2048 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 # Level 100 to Level 200: Northwest interior terrazzo stair has one
continuous handrail. Allow to add 2nd handrail due to width of stairs.
AD0000 Flooring - Junior School 25 1974 -17 2015 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.011 sf Marmoleum sheet flooring at stair treads, risers and landings is in good
condition with localized deterioration (cracking) at upturn junctions. Allow
for repairs in short term and replace in longer term.
AD0000 Flooring - Junior School 20 1974 -22 2015 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.006 LS Carpet flooring at main stairs is in good condition.
AD0000 Guards 40 1974 2 2017 Fair Appearan
ce
5-Does
Not Meet
Current
Code
$ 10 $ 10 $ 0.100 lf 100 Steel framed guards with wood handrail and glazing are installed at the
second floor. Guard height is slightly below current standards at 41.5".
Guards are not considered compliant as they are climbable. Allow for short
term modifications.
$ 10
AD0000 Handrails 40 1974 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 LS Level 400: Wood handrails on either side of balcony loft require height
adjustment and relocation to ensure proper mounting clearance to wall.
AD0000 Metal Stairs Metal Pan Type 100 1974 58 2073 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ - # 0 North and south exit stairs are steel with concrete pan infill. Textured strips
are installed on nosings. Tubular steel handrails and guards are installed.
Steel components have been painted. Handrail and guard heights are
compliant where measured.
AD0000 Metal Ladders Vertical Metal Ladders 30 1994 8 2023 Fair Functiona
lity
4-
Recomm
ended
$ 3 $ 3 $ 3.000 # 1 Typical steel access ladder on the west elevation, providing access to the
flat roof, is in fair condition.
$ 3
AD0000 Metal Stairs Metal Pan Type 75 1974 33 2048 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 65.000 # Levels 200 and 100: Steel framed stairs at northeast corner exit stair 8 are
in good condition. Replacement not anticipated. Guards at 42" in height.
Finished with vinyl floor tile and gypsum board ceiling.
AD0000 Metal Stairs Metal Type 30 1974 -12 2003 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 1.500 # Sub-Basement Level: Steel stair at Carpenter Shop to Exit #19 door is in
fair condition. Allow for shorter term refurbishment only.
AD0000 Railings and Balustrades 40 1974 -2 2013 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.125 lf Steel pipe handrails are in good condition throughout the stairwells. No
replacement carried over the study period. Guard height, handrail
configuration and picket spacings are compliant. Repaint handrails and
guards in longer term.
AD0000 Wood Stairs Wood & Steel
Components
75 1974 33 2048 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 14.000 # Levels 400, 300, 200 and 100: Southeast Stairwell to exit Door #17 with
low guard, wood framed, rubber floor and finish.
AD0000 Wood Stairs 75 1974 33 2048 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 # Central stair to the second floor is wood framed and finished with carpet.
Steel guards with wood handrails are installed. Handrails are compliant,
however they do not extend beyond the stair. This was likely acceptable at
the time of construction due to the high traffic area. Replacement of carpet
is included with flooring.
AD0000 Wood Stairs 40 1974 -2 2015 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 1.500 LS Level 400: Allow to add handrail to 4th Floor Corridor at east end stair to
service roof exit.
C2020 Stair Finishes
C30 Interior Finishes $ -
C3010 Wall Finishes
Page 8 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Acoustical Treatment 22 2010 16 2031 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.012 sf 200 Level Floor or C Level: C29 Library is finished with vinyl tile floor,
carpet, painted concrete block and painted gypsum board ceiling.
Includes four offices.
$ -
AD0000 Concrete Wall Finishes 40 1974 -2 2013 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.005 sf 000 Level Floor or A Level: Hall is finished with older vinyl tile floor,
painted concrete block and lay-in acoustical tile ceiling.
AD0000 Gypsum Board Walls
Finishes
45 2010 39 2054 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.016 sf 000 Level Floor: A24 Locker Room - finished with older vinyl tile, full
height lockers, painted block walls and newer lay-in ceiling tile.
AD0000 Interior Wall Painting 8 2010 2 2017 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.003 sf 200 Level Floor: Storage Lab Rooms and C30 Slop Sink Room are in
need of updating.
$ -
AD0000 Other Wall Finishes 15 2010 9 2024 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.011 sf 500 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ -
AD0000 Plaster Wall Finishes 45 2010 39 2054 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.016 sf 000 Level Floor: A27 Bio Lab was recently refinished with new
furnishings, lay-in acoustical ceilings tiles with older vinyl floor tile. All new
furnishings.
AD0000 Stone Faced Wall
Finishes
45 2010 39 2054 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.037 sf 200 Level Floor or C Level: Hall is finished with older vinyl tile floor,
painted concrete block and lay-in acoustical tile ceiling.
AD0000 Tile Wall Finishes Ceramic Tile 35 2010 29 2044 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.022 sf 100 Level Floor: Classrooms and Study Rooms are finished with vinyl
floor tile, painted block and drywall walls and lay-in tile ceilings. Includes
B39, B38, B37, B20 Science Lab, B19, B18, B17, B16, B15. Fume hood
by Advanced HRPA Technologies (model# 7321002, serial# 4176-02) .
AD0000 Tile Wall Finishes Cut Natural Stone Tile 35 2010 29 2044 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.023 sf 100 Level Floor: Storage areas such as the B40 Slop Sink Room require
immediate updating of finishes. B40 Electrical Room requires refinishing.
AD0000 Tile Wall Finishes Glass Mosaic 35 2010 29 2044 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.025 sf Allow to update older Washroom to barrier free type.
AD0000 Tile Wall Finishes Metal Tile 35 2010 29 2044 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.016 sf 100 Level Floor: Student Washroom is finished with older ceramic floor
tile, painted plaster walls with ceramic mosaic tile and lay-in tile ceilings.
Includes 33" wide door with auto opener, 34.25" barrier free stall, ceramic
tile floor and ceramic mosaic tile walls, Duravit pedestal type sink at 33.25"
high with uninsulated piping at 9" back, wall hung American Standard with
Teck toggle, metal stall partitions
AD0000 Tile Wall Finishes Plastic Tile 35 2010 29 2044 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.012 sf 100 Level Floor: Offices and Copy Room - vinyl tile floors, newer lay-in
acoustical ceiling tiles, plaster walls. Includes B45, B49, B50, B51
(carpet), B51, B53, B54, B46, B55
AD0000 Tile Wall Finishes Quarry Tile 35 2010 29 2044 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.022 sf 100 Level Floor: Staff Washrooms (2) at Lounge are finished with older
and newer ceramic floor tile, painted plaster walls and ceilings. Fixtures
include older American Standard water closet and vanity. 2nd Washroom
at Lounge has 3 older wall hung American Standard water closets with
auto flush and two vitreous clay sinks. Allow to update.
AD0000 Veneer Plaster Finishes 35 2010 29 2044 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.012 sf 100 Level Floor or B Level: Hall is finished with older vinyl tile floor,
painted concrete block and lay-in acoustical tile ceiling.
AD0000 Wall Coverings 8 2010 2 2017 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.009 sf 200 Level Floor: Office C11 has newer carpet, painted gypsum board and
older lay-in tile ceiling.
$ -
AD0000 Wall Paneling 25 2010 19 2034 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.012 sf 0 Acoustical wall paneling is installed in the Boardroom.
AD0000 Wall Trim and
Decoration
8 2010 2 2017 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 15.000 LS 200 Level Floor: Classrooms C12, C13 are finished with vinyl floor tile,
C14 has carpet, painted block and drywall walls and lay-in tile ceilings.
$ -
C3020 Floor Finishes
AD0000 Access Flooring 20 2010 14 2029 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.016 sf 513 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ -
AD0000 Carpet 8 1994 3 2018 Fair Appearan
ce
4-
Recomm
ended
$198.000 $0.000 $ 0.009 sf 22000 Fitness Room, Offices, and second floor areas are finished with sheet type
carpeting. Carpet tiles are installed in the Security Office. Wear was noted
in high traffic areas.
$ -
Page 9 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Concrete Floor Finishes 12 2010 6 2021 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.010 sf 500 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ -
AD0000 Floor Painting 6 2010 0 2015 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.003 sf 515 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ -
AD0000 Floor Topping 25 2010 19 2034 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.010 sf 516 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Floor Treatment 20 2010 10 2025 Good Building
Integrity
1-
Currently
Critical
$90.000 $0.000 $ 0.015 sf 6000 Change Room, Washroom, and Janitor Room floors are finished with a
textured coating on the concrete slabs. Minor cracking was noted
throughout. The flooring is functional.
$ -
AD0000 Other Floor Finishes 20 2010 14 2029 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.015 sf 518 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ -
AD0000 Other Wall Finishes 15 2010 9 2024 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 19.011 sf 519 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ -
AD0000 Other Wall Finishes 15 2010 9 2024 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 20.011 sf 520 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ -
AD0000 Other Wall Finishes 15 2010 9 2024 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 21.011 sf 521 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ -
AD0000 Other Wall Finishes 15 2010 9 2024 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 22.011 sf 522 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ -
AD0000 Other Wall Finishes 15 2010 9 2024 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 23.011 sf 523 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ -
AD0000 Resilient Flooring 20 1994 5 2020 Good Building
Integrity
1-
Currently
Critical
$54.000 $0.000 $ 0.012 sf 4500 Basement and first floor Corridors and Cafeteria are finished with textured
rubber flooring. The flooring is in fair condition overall with localized wear.
The flooring is functional though dated.
$ -
AD0000 Stone Flooring 75 2010 69 2084 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.012 sf 509 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Terrazzo Floor Finishes 45 1974 3 2018 Good Building
Integrity
1-
Currently
Critical
$61.500 $0.000 $ 0.041 sf 1500 Main entrance Vestibule and Foyer are finished with terrazzo flooring.
Minor cracking was noted.
$ -
AD0000 Tile Floor Finishes Ceramic Tile 30 2010 24 2039 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.028 sf 501 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Tile Floor Finishes Cut Natural Stone Tile 30 2010 24 2039 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.026 sf 506 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Tile Floor Finishes Glass Mosaic 30 2010 24 2039 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.028 sf 503 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Tile Floor Finishes Metal Tile 15 2010 9 2024 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.018 sf 505 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ -
AD0000 Tile Floor Finishes Plastic Tile 15 2010 9 2024 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.013 sf 504 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ -
AD0000 Tile Floor Finishes Quarry Tile 30 2010 24 2039 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.025 sf 502 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Traffic Coatings 20 2010 14 2029 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.008 sf 517 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ -
AD0000 Unit Masonry Flooring 75 2010 69 2084 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.010 sf 510 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Wood Flooring 25 2010 19 2034 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.022 sf 508 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
C3030 Ceiling Finishes
AD0000 Acoustical Treatment 25 1994 3 2018 Fair $352.000 $352.000 $ 0.016 sf 22000 Lay-in ceiling tiles are installed throughout the Offices and Storage
Rooms. Tiles and T-bar framing are in fair condition overall. Localized
staining and damaged framing were noted. Allow for short term repairs
and then replacement.
$ 352
AD0000 Ceiling Paneling 30 1994 8 2023 Good $52.500 $352.000 $ 0.015 sf 3500 Suspended ceiling panels are installed throughout the first floor Corridors,
Cafeteria, and Board Room. Paneling is in fair condition overall but dated.
$ 352
AD0000 Ceiling Trim and
Decoration
15 2010 9 2024 Good $0.000 $352.000 $ 15.000 LS 530 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ 352
Page 10 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Concrete Ceiling
Finishes
45 2010 39 2054 Good $0.000 $0.000 $ 0.006 sf 523 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Gypsum Board Finishes 45 2010 39 2054 Good $10.800 $0.000 $ 0.018 sf 600 Ceilings in the Washrooms, Reception area, Vestibules, and Boardroom
are finished with painted gypsum board. Gypsum board is expected to last
the life of the building. Repairs are considered maintenance.
AD0000 Interior Ceiling Painting 8 2010 2 2017 Good $0.000 $352.000 $ 0.004 sf 529 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ 352
AD0000 Other Ceiling Finishes Abrasion Resistant
Coatings
12 2010 6 2021 Good $0.000 $352.000 $ 0.005 sf 536 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ 352
AD0000 Other Ceiling Finishes Chemical Resistant
Coatings
10 2010 4 2019 Good $0.000 $352.000 $ 0.006 sf 543 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ 352
AD0000 Other Ceiling Finishes Concrete and Masonry
Coatings
12 2010 6 2021 Good $0.000 $352.000 $ 0.010 sf 538 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ 352
AD0000 Other Ceiling Finishes Elastomeric Coatings 25 2010 19 2034 Good $0.000 $0.000 $ 0.015 sf 539 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Other Ceiling Finishes Fire Resistant Paint 25 2010 19 2034 Good $0.000 $0.000 $ 0.025 sf 541 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Other Ceiling Finishes Graffiti Resistant
Coatings
10 2010 4 2019 Good $0.000 $352.000 $ 0.006 sf 544 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ 352
AD0000 Other Ceiling Finishes High Build Glazed
Coatings
12 2010 6 2021 Good $0.000 $352.000 $ 0.005 sf 537 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ 352
AD0000 Other Ceiling Finishes Intumescent Paint 25 2010 19 2034 Good $0.000 $0.000 $ 0.035 sf 542 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Other Ceiling Finishes Linear Metal 30 2010 24 2039 Good $0.000 $0.000 $ 0.023 sf 531 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Other Ceiling Finishes Linear Wood 35 2010 29 2044 Good $0.000 $0.000 $ 0.020 sf 534 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Other Ceiling Finishes Mirror Panels 30 2010 24 2039 Good $0.000 $0.000 $ 0.040 sf 532 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Other Ceiling Finishes Suspended Decorative
Grids
25 2010 19 2034 Good $0.000 $0.000 $ 0.006 sf 535 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Other Ceiling Finishes Textured Gypsum
Panels
45 2010 39 2054 Good $0.000 $0.000 $ 0.020 sf 533 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Other Ceiling Finishes Textured Plastic 25 2010 19 2034 Good $0.000 $0.000 $ 0.015 sf 540 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Plaster Ceiling Finishes 45 2010 39 2054 Good $0.000 $0.000 $ 0.025 sf 525 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Veneer Plaster Finishes 35 2010 29 2044 Good $0.000 $0.000 $ 0.014 sf 527 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
D SERVICES $ - $ 40 $ - $ 20 $ 300 $ - $ 18 $ - $ - $ 335 $ - $ - $ - $ - $ 20 $ 14 $ - $ - $ - $ 201
D10 Conveying $ -
D1010 Elevators and Lifts
AD0000 Elevators Commercial 35 1974 3 2018 Fair Functiona
lity
3-Not Yet
Critical
$ 60 $ 60 $ 60.000 LS 1 The building is equipped with the original hydraulic elevator by
Montgomery. The elevator has a capacity of 1350 kg. Allow for elevator
modernization in the short term as parts may become obsolete and repairs
may become costly.
$ 60
AD0000 Elevators Cab Finishes 18 1994 3 2018 Fair Appearan
ce
4-
Recomm
ended
$ 10 $ 10 $ 10.000 LS 1 Elevator cab is finished with carpet, laminate wall panels, and acrylic
ceiling panels. The carpet is worn.
$ 10
D1030 Other Conveying
SystemsAD0000 Dumbwaiters 35 1948 -33 1982 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 12.000 LS The Cober dumbwaiter at the Centre Wing/Service Wing is original and
currently non-operational. It has a capacity of 227 kg. No allowances are
carried to renovate the equipment.
D20 Plumbing $ -
D2010 Plumbing Fixtures
AD0000 Water Closets 22 1994 8 2023 Good Building
Integrity
4-
Recomm
ended
$ 19 $ 19 $ 1.200 # 16 Washrooms and basement Change Rooms are equipped with American
Standard flush valve water closets.
$ 19
Page 11 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Urinals 22 1994 8 2023 Good Building
Integrity
4-
Recomm
ended
$ 6 $ 6 $ 1.200 # 5 Men's Washrooms and Change Room are equipped with urinals. Flush
valve urinals are replaced with waterless units as needed.
$ 6
AD0000 Lavatories 22 1994 8 2023 Good Building
Integrity
4-
Recomm
ended
$ 14 $ 14 $ 1.000 # 14 Washrooms and basement Change Rooms are equipped with American
Standard vitreous clay lavatories with newer lever type faucets.
$ 14
AD0000 Sinks 22 1994 8 2023 Good Building
Integrity
1-
Currently
Critical
$ 1 $ 1 $ 0.750 # 1 Concrete mop sinks are installed in the Janitor's Rooms. Moderate
staining was noted.
$ 1
AD0000 Sinks 22 1999 5 2020 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.750 # Eight stainless steel sinks with goose neck style faucets are in good
condition at the Kindergarten Classrooms. Allow for longer term
replacement. Cost covered under Interior Finishes component.
$ -
AD0000 Sinks 22 1999 5 2020 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 1.200 # Two precast concrete slop sink with wall faucet are provided at both Slop
Sink Rooms. Cost covered under Interior Finishes component.
$ -
AD0000 Washrooms Barrier Free 22 1999 5 2020 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 # Two unisex, two-piece barrier free Washrooms are installed. Includes
32.5" wide door, extended vanity at 32.5" high, American Standard water
closet with Teck toggle flush, 33" high back and L type bars, painted
gypsum board ceiling with ceramic tiled floor and walls. Cost covered
under Interior Finishes component.
$ -
AD0000 Other Hose Bibs 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.000 LS Standard, non-freeze hose bibs are installed along the exterior walls. $ -
AD0000 Showers 30 1994 8 2023 Good Building
Integrity
4-
Recomm
ended
$ 135 $ 135 $ 15.000 LS 9 Basement Change Rooms are equipped with showers with lever type
faucets.
$ 135
AD0000 Drinking Fountains and
Coolers
20 2010 14 2029 Good Building
Integrity
1-
Currently
Critical
$ 8 $ 8 $ 2.500 # 3 Stainless steel drinking fountains are installed on each floor level.
Fountains were manufactured by Filtrine. The fountains are generally
acceptable for barrier-free use.
$ 8
AD0000 Other Plumbing Fixtures Eyewash 15 1999 -2 2013 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 # Bradley emergency eye wash station is located at the Main Mechanical
Room.
AD0000 Drinking Fountains and
Coolers
20 2007 11 2026 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 # Dual stainless steel wall mounted fixture at Gym corridor is in good
condition.
$ -
AD0000 Drinking Fountains and
Coolers
20 1996 0 2015 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 # Wall mounted, stainless steel drinking fountain located at Level B Hallway
of 1978 Wing.
$ -
AD0000 Other Plumbing Fixtures Eyewash 15 2006 5 2020 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 # Bradley emergency eye wash station is located at the Lab Room B23. $ -
D2020 Domestic Water
DistributionAD0000 Water Supply Pipe 10 1999 -7 2008 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 10.000 LS Copper distribution piping and valves throughout the facility are in good
serviceable condition with minimal noted damage. Allow for longer term
repairs only at 10 year intervals.
AD0000 Water Supply Pipe Main Service 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 LS 4" diameter PVC pipe to 3" diameter copper service complete with by-pass
and Watts (model# 009 RP) backflow preventer. The piping is insulated
with fiberglass and PVC jacket. Minor insulation damage was noted.
AD0000 Water Supply Pipe Main Service 40 2006 30 2045 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 LS 4" diameter PVC pipe at pool tunnel is split to 4" diameter cast iron for the
fire line and 4" diameter copper for the domestic water system. Meter not
located here; drawings indicated meter here.
Page 12 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Water Supply Pipe Plumbing Distribution &
Valves
40 1994 18 2033 Fair Building
Integrity
4-
Recomm
ended
$ 45 $ 45 $ 45.000 LS 1 Copper distribution piping is installed and typically insulated. $ 45
AD0000 Water Supply Pipe Plumbing Distribution &
Valves
5 1961 -50 1965 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS Allowance to commence piping replacements in the South Wing every 5
years.
AD0000 Water Supply Pipe Plumbing Distribution &
Valves
5 1979 -32 1983 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Allowance to commence piping replacements in the North Wing every 5
years.
AD0000 Water Supply Pipe Plumbing Distribution &
Valves
40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 120.000 LS Copper piping throughout the North Addition is in good condition.
AD0000 Water Supply Pipe Plumbing Distribution &
Valves
40 2006 30 2045 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 130.000 LS Copper piping throughout the Athletic Centre is in good condition.
AD0000 Pipe Insulation 40 2006 30 2045 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS Pipe covering, fiberglass with all service jacket, is in good condition at the
Athletic Centre Mechanical Room, stairwells and at the pool tunnel service
areas. The piping is demarked with service type and directional flow as
required. Typical in service areas also.
AD0000 Pipe Insulation 40 2006 30 2045 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.000 LS Pool pipe insulation at heat exchanger HX-2 is omitted on the domestic
cold water service. Allow to add in the short term.
AD0000 Pipe Insulation 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Glycol chilled water supply and return piping are insulated with fiberglass
and PVC jacket.
AD0000 Pipe Insulation 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS Domestic water supply piping is insulated with fiberglass and PVC jacket.
Localized damage at Mechanical Room.
AD0000 Domestic Water Storage
Tanks
40 2005 29 2044 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 29.000 # The vertical steel domestic hot water tank DHWT-2 (serial# 04-219, CRN#
H6839.52T184) is located in the Athletic Mechanical Room. The tank was
relined in 2013 by Hydrastone including new anodes. Manufactured by
Clemmer with 661 Imperial Gallon capacity each.
AD0000 Domestic Water Storage
Tanks
40 2005 29 2044 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 29.000 # The vertical steel domestic hot water tank DHWT-1 (serial# 05-269, CRN#
M1073.523) is located in the Athletic Mechanical Room. The tank was
relined in 2013 by Hydrastone including new anodes.
AD0000 Domestic Water Storage
Tanks
40 1999 23 2038 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 # Manufacture and capacity is unknown. Inspected and relined in 2014 by
Hydrastone. Insulated with fiberglass and PVC jacket.
AD0000 Domestic Water Storage
Tanks
40 1987 11 2026 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 # Drummond Welding & Steel Works tank at Boiler Room is in fair condition.
Vertical hot water storage tank was inspected with new anodes installed in
2013 by Hydrastone.
$ -
AD0000 Domestic Water Storage
Tanks
40 1978 2 2017 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 # Clemmer Steelcraft tank at North Wing Level A Mechanical Room is in fair
condition. Inspected in 2013 by Hydrastone. Includes small B&G 1/3-HP
circulating pump. Allow for refurbishment/repairs then replacement.
$ -
D2030 Sanitary Waste
AD0000 Waste and Vent Pipe Sewage Pumps &
Tanks
20 1994 3 2018 Fair Building
Integrity
3-Not Yet
Critical
$ 15 $ 15 $ 5.000 # 3 Three sump pumps with alarm panels by Scarborough Pumps are
installed in the basement Mechanical Room. Pump functions (i.e. storm,
sanitary) are not labelled (maintenance).
$ 15
AD0000 Waste and Vent Pipe Sewage Pumps &
Tanks
35 1979 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 LS North Wing tank is in fair condition.
AD0000 Waste and Vent Pipe Sewage Pumps &
Tanks
20 1999 3 2018 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 # 1999 Kitchen pumps are in fair condition. Listed as UP-10 and UP-11, 3-
HP motors by Barnes.
$ -
AD0000 Waste and Vent Pipe Sewage Pumps &
Tanks
35 1999 18 2033 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 40.000 LS 1999 Kitchen grey water tank is in fair condition. $ -
AD0000 Waste and Vent Pipe Grease Interceptor 35 1999 18 2033 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 45.000 LS Kitchen Acorn grease interceptor is in fair condition. $ -
AD0000 Waste and Vent Pipe Sewage Pumps &
Tanks
20 2006 10 2025 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 7.500 # Sanitary pit, Plad wall control panel and sump pumps SP-3 and SP-4 are
located in the service tunnel of the Pool. Tank and pumps are not
accessible. Waste is ejected out to 4" pipe out south wall.
$ -
AD0000 Waste and Vent Pipe Sewage Pumps &
Tanks
20 2006 10 2025 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 7.500 # Sanitary pit, Plad wall control panel and sump pumps SP-3 and SP-4 are
located in the service tunnel of the Pool. Tank and pumps are not
accessible. Waste is ejected out to 4" pipe out south wall.
$ -
AD0000 Waste and Vent Pipe Sewage Pumps &
Tanks
20 1979 -17 1998 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 8.000 # Boiler Room pumps are in fair condition. Allow to update in short term.
AD0000 Waste and Vent Pipe Sewage Pumps &
Tanks
35 1979 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 35.000 LS Boiler Room tank is in fair condition. Allow to update in short term.
Page 13 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Waste and Vent Pipe 40 1974 3 2018 Fair Building
Integrity
3-Not Yet
Critical
$ 20 $ 20 $ 20.000 LS 1 ABS sanitary is installed to the cast iron mains. Allow for repairs and
localized replacement as needed.
$ 20
AD0000 Elevator Sump 25 1999 8 2023 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 LS Elevator sump pump UP-12 is concealed from view. $ -
D2040 Rainwater Drainage
AD0000 Pipe 40 1999 23 2036 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 LS Cast iron storm drainage piping is used throughout the building. The
drainage piping, and all associated fittings, are in good condition. Piping is
uninsulated on vertical runs and insulated at horizontal runs at roof deck.
No allowances carried over the study period.
AD0000 Drain 25 1999 8 2021 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 1.500 # Control flow roof drains are installed over the main roof areas. The drains
are in good condition. Vegetation cleanout is required; considered an
operational/maintenance item.
$ -
AD0000 Pipe 40 1999 23 2036 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS Cast iron storm drainage piping is used throughout the building. The
drainage piping, and all associated fittings, are in good condition. Piping is
uninsulated on vertical runs and insulated at horizontal runs at roof deck.
No allowances carried over the study period.
AD0000 Drain 25 1999 8 2021 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.600 # Control flow roof drains are installed over the main roof areas. The drains
are in good condition. Vegetation cleanout is required; considered an
operational/maintenance item.
$ -
AD0000 Pipe 40 2006 30 2043 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS Cast iron storm drainage piping is used throughout the building. The
drainage piping, and all associated fittings, are in good condition. Piping is
uninsulated on vertical runs and insulated at horizontal runs at roof deck.
No allowances carried over the study period.
AD0000 Drain 25 2006 15 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.600 # Control flow roof drains are installed over the main roof areas. The drains
are in good condition. Vegetation cleanout is required; considered an
operational/maintenance item.
$ -
AD0000 Waste Piping Equipment Submersible Pump &
Control
20 1999 3 2018 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Storm weeping tile pit, sand settling pit, Plad wall control panel and sump
pumps SP-1 and SP-2 are located in the serviced tunnel of the Pool. Tank
and pumps are not accessible.
$ -
D2090 Other Plumbing
SystemsAD0000 Compressed Air Systems Air Compressors 25 1995 4 2019 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.500 LS Devilbiss, dual type compressor is in good condition. $ -
AD0000 Pool and Fountain
Equipment
Balancing Tank 30 2006 20 2035 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 30.000 LS Balancing tank is manufactured by Nemato (model# NBT-60-1460) and
has a 1460 US Gallon capacity.
AD0000 Pool and Fountain
Equipment
Waste Water Holding
Tank
30 2006 20 2035 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.500 LS Waste water holding tank is constructed from polyethylene and is
manufactured by Bonar.
AD0000 Pool and Fountain
Equipment
Chlorine Tank & Pump 15 2006 5 2020 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.500 LS Chlorine holding tank is constructed from polyethylene and is
manufactured by Bonar.
$ -
AD0000 Pool and Fountain
Equipment
Muriatic Acid Tank &
Pump
15 2006 5 2020 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.500 LS Muriatic Acid holding tank is constructed from polyethylene and is
manufactured by Bonar.
$ -
AD0000 Pool and Fountain
Equipment
Fluid Strainers 30 2006 20 2035 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 LS National Line fluid straining systems by US Filter.
AD0000 Pool and Fountain
Equipment
Dosing Pumps 7 2006 -3 2012 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 1.500 LS Chemtrol chemical feed control panel (model# PC3000) and Stennec
dosing pumps are in fair condition.
AD0000 Pool and Fountain
Equipment
Water Fill 30 2006 20 2035 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 LS Fill line has separate meter and backflow preventer as required.
AD0000 Pool and Fountain
Equipment
Sand Filters 30 2006 20 2035 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 55.000 LS Three high rate sand filters by Nemato (model# NFS-34-A-153) are in
good condition.
Page 14 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Pool and Fountain
Equipment
Circulating Pumps 20 2006 10 2025 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS Two 15-HP Armstrong vertical in-line circulating pumps are in good
condition. Equipped with Baldor 15-HP motors at 85% efficiency.
$ -
AD0000 Pool and Fountain
Equipment
Circulating Pumps 20 2006 10 2025 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS Two 15-HP Armstrong vertical in-line circulating pumps are in good
condition. Equipped with Baldor 15-HP motors at 85% efficiency.
$ -
AD0000 Pool and Fountain
Equipment
Eyewash 20 2006 10 2025 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.000 LS Bradley emergency eye wash station is located at the Main Mechanical
Room.
$ -
AD0000 Pool and Fountain
Equipment
Pool Tunnel Supply Fan 20 2006 10 2025 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.500 LS 3/4 HP air supply fan at tunnel is in good condition. The Controller was
not operational however. Allow for verification of system.
$ -
AD0000 Pool and Fountain
Equipment
Pool Supply Air Ducting 30 2006 20 2035 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 LS Conventional supply air ducting is installed at the pool tunnel.
AD0000 Pool and Fountain
Equipment
Vacuum Breaker 20 2006 10 2025 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.500 LS VacAlert Industries vacuum breaker device (VAC 2000) is in good
condition.
$ -
AD0000 Pool and Fountain
Equipment
Pool Piping & Fittings 30 2006 20 2035 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 150.000 LS PVC supply and return piping, copper fill piping, back-flow preventer, etc.
are in good condition. Allow for long term replacements.
AD0000 Pool and Fountain
Equipment
Pool Basin 30 2006 20 2035 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 75.000 LS Concrete pool basin is in good condition with localized vertical wall cracks
(6). Some cracks were active. Allow for repairs to basin in short term and
longer term major repairs.
AD0000 Pool and Fountain
Equipment
Railings 30 2006 20 2035 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.000 LS Painted steel guard and access ladders at pool tunnel are in good
condition. Height of guard at 42" as required.
AD0000 Chemical Treatment 15 2006 5 2020 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 # Pall (model# T910031, serial# HH) inline filter and Ashland 2 gallon pot
feeder (model# VTF-2HP) is located at the Athletic Centre Mechanical
Room. Serves the Athletic and South Wing heating system.
$ -
AD0000 Chemical Treatment 15 2006 5 2020 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 # Pall (model# T910031, serial# HH) inline filter and Ashland 2 gallon pot
feeder (model# VTF-2HP) is located at the Pool Tunnel area.
$ -
AD0000 Chemical Treatment 15 1999 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 # Pall (model# T910031, serial# HH) inline filter and Ashland 2 gallon pot
feeder (model# VTF-2HP) is located at the 1999 Mechanical Room.
AD0000 Chemical Treatment 15 1999 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 7.000 # Chemical sulphite and alkalinity builder boiler chemical systems.
AD0000 Chemical Treatment 15 1999 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.500 # Inline filter and Neptune by-pass feeder located in Mechanical Room.
AD0000 Chemical Treatment 15 1999 -2 2013 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.500 # Filterite inline filter and Ashland 2 gallon pot feeder (model# VTF-2HP) is
located at the Main Mechanical Room. Serves the heating system.
AD0000 Chemical Treatment 15 1999 -2 2013 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.500 # Filterite inline filter and Ashland 2 gallon pot feeder (model# VTF-2HP) is
located at the Main Mechanical Room. Serves the glycol system.
Page 15 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Chemical Treatment 20 1999 3 2018 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 10.000 # Glycol holding tank and control panel are in fair condition overall. $ -
AD0000 Chemical Treatment 20 1999 3 2018 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 10.000 # Glycol holding tank, Leeson motor and control panel are in good condition
overall.
$ -
D30 HVAC $ -
D3010 Energy Supply
AD0000 Gas Supply 15 2006 5 2020 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.000 LS Gas supply piping throughout the facility is in good condition where
observed. Allow for full repainting at the Boiler Room and Pool tunnel
areas due to wear and corrosion. Replacement of piping is carried with
the equipment being served by it.
$ -
D3020 Heat Generation
AD0000 Steam Boilers Gas-Fired 40 1966 -10 2005 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 135.000 # The Upper School is heated by two 4,500 MBH York Shipley, three-pass
Scottish Marine steam type boilers. The 1966 gas-fired boilers are located
in the main Mechanical Room. Allow for future refurbishment in 5 years.
The boilers were re-tubed in 2006 and burners were replaced in 2007 with
Fuel Master model# CG-165. System apparently operates at 85%
efficiency as reported.
AD0000 Hot Water Boilers Gas-Fired 25 2005 14 2029 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 27.000 # Laars gas-fired hot water boilers for building heating (model#
PNCH1000NACN2CXX, serial# C05156471 and 2) are rated at 999.96
MBH input and 839.20 MBH output. Located at the Athletic Centre
Mechanical Room. The boilers are equipped with a EMC (model# S-112)
sequencer control.
$ -
AD0000 Hot Water Boilers Gas-Fired 25 2005 14 2029 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 # Laars gas-fired hot water boiler for domestic hot water (model# , serial# )
is located at the Athletic Centre Mechanical Room. The data label was
damaged.
$ -
AD0000 Hot Water Boilers Gas-Fired 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 # Teledyne Laars gas-fired hot water boiler for domestic hot water (model#
VW0715INC1CC , serial# C98K04444) is located at the North 1999
Addition Mechanical Room. Rated at 715 MBH input and 579 MBH
output.
$ -
AD0000 Hot Water Boilers Gas-Fired 25 2005 14 2029 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 35.000 # RBI 8900 Series (model# HW1050NOE1COG, serial# 050435496)
domestic hot water boiler at Main Boiler Room is in good condition. Rated
at 1050 MBH input. Denoted as DHWH #2.
$ -
AD0000 Hot Water Boilers Gas-Fired 25 2013 22 2037 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 # Hydrotherm (model# KN-2, serial# KN2-2013) gas-fired direct-vent boiler
complete with inline General Filtration filter and Neptune by-pass feeder.
Serves a newer heating loop. Also includes a small expansion tank and
two B&G fractional horsepower circulating pumps.
AD0000 Hot Water Boilers Gas-Fired 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 37.000 # Teledyne Laars gas-fired hot water boilers for building heating (model#
HH1670IN11K1CCAL, serial# C98K04442 and C98K04443) are rated at
1,670 MBH input and 1352 MBH output. Located at the North 1999
Addition Mechanical Room. The boilers are equipped with a sequencer
control.
$ -
AD0000 Hot Water Boilers Gas-Fired 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 # Teledyne Laars gas-fired hot water boilers for domestic water heating
(model# VW0715IN11C1CCXX) is rated at 715 MBH input and 579 MBH
output. Located at the North 1999 Addition Mechanical Room.
$ -
AD0000 Hot Water Boilers Gas-Fired 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 37.000 # Teledyne Laars gas-fired hot water boilers for building heating (model# HH
1200) are rated at 1,200 MBH input and 972 MBH output. Located at the
Junior School Mechanical Room. The boilers are equipped with a
sequencer control. The boilers serve a two pipe distribution system to the
various radiant heaters and panels.
$ -
AD0000 Hot Water Boilers Gas-Fired 15 2005 4 2019 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 16.000 # Rheem gas-fired hot water boiler for domestic hot water (model# G100-75
, serial# RRNG 0205D06056) is located at the Junior School Mechanical
Room. Rated at 75 MBH input.
$ -
AD0000 Other Heat Generation
Systems
Condensate Return
Feedwater Tank
25 1993 2 2017 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 35.000 # Condensate return tank is located in the Main Mechanical Room.
Includes older feed water and condensate return pumps.
$ -
AD0000 Other Heat Generation
Systems
Heating Controls 25 1979 -12 2003 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 # Allow to update older pneumatic controls, compressor and dryer at main
Mechanical Room to electric type (BAS).
AD0000 Other Heat Generation
Systems
Heating Controls 25 1979 -12 2003 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 # Allow to update older pneumatic controls, DeVilbiss compressor and dryer
at main Mechanical Room to electric type (BAS).
Page 16 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Other Heat Generation
Systems
Heating Controls 25 1979 -12 2003 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 # Allow to update older pneumatic controls, DeVilbiss compressor and dryer
at main Mechanical Room to electric type (BAS).
AD0000 Other Heat Generation
Systems
Heating Controls 25 1985 -6 2009 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 # Allow to update older pneumatic controls, compressor and dryer at North
Mechanical Room to electric type (BAS).
AD0000 Other Heat Generation
Systems
Condensate Tank 25 1979 -12 2003 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 7.500 # Condensate tank is located in the North Mechanical Room Level A.
AD0000 Other Heat Generation
Systems
General Utility Pumps 20 1994 5 2020 Good Building
Integrity
1-
Currently
Critical
$ 12 $ 12 $ 6.000 # 2 Two 25 HP heat pump pumps are installed in the Penthouse. $ 12
AD0000 Other Heat Generation
Systems
General Utility Pumps 15 1994 5 2020 Good Building
Integrity
1-
Currently
Critical
$ 6 $ 6 $ 2.000 # 3 Two 10 HP condenser water pumps are installed in the Penthouse. $ 6
AD0000 Other Heat Generation
Systems
Expansion Tank 35 2006 25 2040 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.000 # Floor mounted Expanflex steel expansion tank at Athletic Centre
Mechanical Room is in good condition.
AD0000 Other Heat Generation
Systems
Expansion Tank 35 1999 18 2033 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Two expansion tanks are located at the main Mechanical Room. $ -
AD0000 Other Heat Generation
Systems
Expansion Tank 35 1948 -33 1982 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.000 LS Remove abandoned expansion tank, piping and refrigeration equipment in
Boiler Room.
AD0000 Other Heat Generation
Systems
Expansion Tank 35 1996 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.000 LS New vertical expansion tank at Boiler Room is in good condition. $ -
AD0000 Other Heat Generation
Systems
Liquid-to-Liquid Heat
Exchangers
35 2006 25 2040 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 19.000 # HX-1, Armstrong unit located in Pool Mechanical Room. Uses hot water
from the main boilers.
AD0000 Other Heat Generation
Systems
Plate type heat
exchanger
35 1994 13 2028 Good Building
Integrity
1-
Currently
Critical
$ 20 $ 20 $ 20.000 # 1 An Alfa Laval plate type heat exchanger is installed in the Penthouse. $ 20
AD0000 Other Heat Generation
Systems
Liquid-to-Liquid Heat
Exchangers
35 2006 25 2040 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 # Glycol heat transfer by steel shell and tube heat exchanger is located at
the Penthouse Mechanical Room.
AD0000 Other Heat Generation
Systems
Liquid-to-Liquid Heat
Exchangers
35 1979 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 21.000 # The North Wing is fed by steam from the main boilers and heats the water
for the 1970 Wing. This unit is quite dated.
AD0000 Other Heat Generation
Systems
Liquid-to-Liquid Heat
Exchangers
35 1966 -15 2000 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 30.000 # The Main Boiler Room unit is operated by steam from the main boilers and
heats the water for the Art House and 3rd and 4th floors of the Centre
Wing. This unit is quite dated.
AD0000 Heating Supply
Insulation
40 1974 2 2017 Fair Energy 3-Not Yet
Critical
$ 20 $ 20 $ 20.000 LS 1 Chilled water piping for cooling is not insulated. Heating piping is insulated
with fibreglass and PVC or canvas wrap. Provide insulation on cooling
piping.
$ 20
AD0000 Heating Supply
Insulation
40 1978 2 2017 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 50.000 LS All heating supply and return piping at the 1978, 1926, 1948 areas are a
combination of fiberglass, asbestos, cellulose all with and without
asbestos fittings. Replace all in longer term as part of retrofit. Includes
pipe chases.
$ -
AD0000 Heating Distribution
Piping
40 1950 -26 1989 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 130.000 LS The distribution piping for the steam and hot water distribution piping is in
need of updating due to age and problematic issues. Allow for staging the
replacement over 10 years as opposed to localized repairs. This includes
the tunnel, North Wing and Centre and South Wings.
AD0000 Heating Distribution
Piping
Valves 40 1950 -26 1989 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 75.000 LS Older stem valves are in need of updating at main Boiler Room and
tunnels. Approximately 65.
AD0000 Heating Distribution
Piping
Valves 40 1950 -26 1989 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 75.000 LS Older stem valves are in need of updating at main Boiler Room and
tunnels. Approximately 65.
Page 17 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Other As-Built Drawings 15 1978 -23 1992 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 LS Partial as-built drawings are available. As there has been significant
changes to systems over the years, including building interior layouts, it is
recommended that a complete set of as-built drawings be prepared
including site, architectural, mechanical, electrical and structural.
D3030 Refrigeration
AD0000 Centrifugal Water
Chillers
Air Cooled Water Chiller 25 1999 8 2023 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 245.000 # McQuay (model# ALR145EY37, serial# 58L8136501) reciprocating type
chiller is rated at 140 tons with 600-V, 3-P,4-W service. The chiller serves
the entire school through the two air handling units. The chiller is
equipped with four 40-HP compressors using HCFC-22 refrigerant
(phased out in 2020). Details on compressor replacement are unknown.
Piping of chiller is insulated with aluminum cover.
$ -
AD0000 Centrifugal Water
Chillers
Compressors 5 2015 4 2019 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 60.000 # Compressor allowance. $ -
AD0000 Centrifugal Water
Chillers
Air Cooled Water Chiller 25 1999 8 2023 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 # The steel framed support for the chiller is in good condition with minor
surface corrosion. Refurbish when replacing chiller. Steel guard at
platform is slightly less than the required 42"; no allowances carried for
rectification.
$ -
AD0000 Centrifugal Water
Chillers
Air Cooled Water Chiller 25 1999 8 2023 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 220.000 # McQuay reciprocating type chiller is rated at 120 tons with 600-V, 3-P,4-W
service. The chiller serves the 1999 Wing and the air handling unit in the
North Mechanical Room that serves the Library and parts of the 1979
Wing. The chiller has four 40-HP compressors using HCFC-22 refrigerant
(phased out in 2020). Details on compressor replacement are unknown.
Piping of chiller is insulated with aluminum cover.
$ -
AD0000 Centrifugal Water
Chillers
Compressors 5 2015 4 2019 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 80.000 # Compressor allowance. $ -
AD0000 Other Kitchen Refrigeration 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.000 # Blanchard Ness (model# TOUS) units located externally are in fair
condition.
$ -
AD0000 Cooling Towers &
Evaporative Coolers
25 1994 3 2018 Fair Functiona
lity
3-Not Yet
Critical
$ 30 $ 30 $ 30.000 # 1 A BAC cooling tower is installed on the roof. No manufacturer's
information was available.
$ 30
D3040 HVAC Distribution
AD0000 Air Distribution Air Handling Units,
packaged indoor
25 1994 3 2018 Fair Functiona
lity
3-Not Yet
Critical
$ 20 $ 20 $ 5.000 # 4 McQuay split system fancoil units are installed throughout the building.
Units are controlled by individual thermostats. The units vary in size. Units
are factory charged with R22 refrigerant. Heating and cooling is provided
hydronically.
$ 20
AD0000 Air Distribution Air Handling Units,
packaged indoor
25 2010 19 2034 Good Functiona
lity
4-
Recomm
ended
$ 20 $ - $ 20.000 # 1 A Johnson/McQuay air handling unit is located in the ceiling of the second
floor Corridor (model# DSH024A1E1AAA0AA, serial# 10030025C). The
unit is factory charged with R410a refrigerant. Vibration insulators are
recommended on the hangars.
AD0000 Air Distribution Air Handling Units,
packaged indoor
25 1994 3 2018 Fair Functiona
lity
3-Not Yet
Critical
$ 100 $ 100 $ 50.000 # 2 Air handling units 1B and 2B by Engineered Air, located in the Penthouse,
provide fresh air to the split systems (model#UPW363C, serial#
19579AHU1B, 19579AHU2B).
$ 100
AD0000 Air Distribution Air Handling Units,
packaged indoor
25 1994 3 2018 Fair Functiona
lity
3-Not Yet
Critical
$ 10 $ 10 $ 10.000 # 1 Heat pump 7, located in the Penthouse, is by Snyder General (model#
LHP22CK, serial# 7YF0348703).
$ 10
AD0000 Air Distribution Air Handling Units,
packaged indoor
25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 125.000 # McQuay AHU-3 (model# CAH035SDAC) provides tempered air to the
Classrooms. Includes circulating pump.
$ -
AD0000 Air Distribution Air Handling Units,
packaged indoor
25 2003 12 2027 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 100.000 # Packaged air handling unit at North Mechanical Room was rebuilt in 2003.
Services portions of the 1979 Wing including the Library. McQuay
(model# CAH025G0AM).
$ -
AD0000 Air Distribution Rooftop package, gas-
fired heating, electric
cooling
25 2006 15 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 70.000 # Packaged unit for new double Gym is rated at 30-Ton. Aaon Coil
Products (model# CA0984, serial# 200506-CCC) central air conditioner.
Listed as RTU-3.
$ -
AD0000 Air Distribution Exposed ductwork
insulation at roof levels
25 2006 15 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 8.500 # Aluminized insulated ducting jacket at roof level is in good condition.
There is localized damage at RTU-3. Allow for repairs and longer term
replacement.
$ -
AD0000 Air Distribution Rooftop package, gas-
fired heating, electric
cooling
25 2006 15 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 37.000 # Aaon packaged unit for old single Gym is rated at 20-Ton. Listed as RTU-
1. Label is illegible.
$ -
Page 18 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Air Distribution Rooftop package, gas-
fired heating, electric
cooling
25 2006 15 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 55.000 # Packaged unit for VAV for Athletic Centre is rated at 22-Ton. Aaon Coil
Products (model# CA0532, serial# 200506-CCC) central air conditioner.
Listed as RTU-2.
$ -
AD0000 Air Distribution Rooftop package, gas-
fired heating, electric
cooling
25 2006 15 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 37.000 # Packaged unit for Pool is rated at 20-Ton. Air Wise (model# TBA-650/RA,
serial# CN-3888) with indirect gas fired heater. Listed as RTU-4.Includes
Aaon (model# CA1118, serial# 200506-CCC) heating/cooling section.
$ -
AD0000 Air Distribution Make-up Air Unit, gas-
fired
25 2006 15 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 33.000 # Make-up air unit for Athletic Centre is rated at 10-Ton. Air Wise Custom
(model# TBA-250/DX-C8, serial# CN-388).
$ -
AD0000 Air Distribution Rooftop package, gas-
fired heating, electric
cooling
25 2006 15 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 17.000 # Aaon packaged unit for main entrance foyer at Athletic Centre is rated at 4-
Ton cooling. Label is illegible. Listed as RTU-5.
$ -
AD0000 Air Distribution Rooftop package, gas-
fired heating, electric
cooling
25 2002 11 2024 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 57.000 # RTU-6 packaged unit for Assembly Hall is in good condition. Rated at 25-
Ton cooling. York (model# D2CG300N3205058ECA, serial#
NCLM029779) is charged with R22 refrigerant. Rated at 400 MBH input.
$ -
AD0000 Air Distribution Rooftop package,
electric cooling
25 1993 2 2015 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 30.000 # Carrier Weathermaker 1 (model# 50LJOO8510) packaged unit for South
Wing was relocated to Athletic Centre and serves Computer Rooms C47
and C48. Referred to as RTU-10. Charged with R22 refrigerant.
$ -
AD0000 Air Distribution Rooftop package, gas-
fired heating, electric
cooling
25 2003 12 2025 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 31.000 # Packaged unit for Business Office is in good condition. Rated at 12.5 Ton
cooling.
$ -
AD0000 Air Distribution Rooftop package,
electric cooling
25 1984 -7 2006 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 # Packaged unit for Day School Office is in fair condition but has reached
the end of its useful service life. Unitary Products Sunline 2000 (model#
D7CG060NO9925A, serial# NGMM084156, 125 MBH heating and R22
refrigerant charge. Listed as RTU7 at roof of 1948 Addition. Ductwork is
fed below to the Offices.
AD0000 Air Distribution Ground Level package,
electric cooling
25 2012 21 2034 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 # Goodman (model# CPG0601403BXXXBA, serial# 1202160927) is factory
charged with R410A, with heating input of 138 MBH, output of 110 MBH .
Unit serves the IT Room and Office.
AD0000 Air Distribution Rooftop package,
electric cooling
25 2005 14 2027 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 # RTU-9, Johnson Controls Unitary Products (model# D2EZ036A06C,
serial# W1F3791633) packaged rooftop unit is rated at 3-Ton and factory
charged with R-410A.
$ -
AD0000 Air Distribution Fans, utility, supply air 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.000 # Barry Blower supply air fan by Penn is installed for the air handling unit in
the Mechanical Room. Has a 5-HP Baldor motor with NEMA nominal
efficiency of 89.5%.
$ -
AD0000 Air Distribution Fans, utility, supply air 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 # Supply fan F-J1 serves the Classrooms. It is manufactured by Barry
(model# 402 ESI, serial# 48M00039) rated at 11530 L/S and 7.46 kW)
complete with Baldor Super-E 10-HP motor and variable speed drive. Fan
is located in Junior School Mechanical Room.
$ -
AD0000 Air Distribution Fans, utility, supply air 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 # Supply fan F-J2 serves the Gym and Lunch area. It is manufactured by
Barry (model# ESI) rated at 762 L/S and 1.50 kW) complete with variable
speed drive. Data tag and motor were not accessible. Fan is located in
Junior School Mechanical Room.
$ -
AD0000 Air Distribution Ducting 40 1994 18 2033 Good Building
Integrity
4-
Recomm
ended
$ 75 $ 75 $ 75.000 LS 1 Conventional ductwork, standard supply air grilles and parabolic diffusers
are installed throughout. Some exposed ductwork is painted.
$ 75
AD0000 Air Distribution Ducting 30 2006 20 2035 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Circular ducting for pool area is located within the pool service tunnel.
Minor wear was noted. Allow for longer term replacement.
AD0000 Air Distribution Ducting 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.900 LS Aluminized insulated ducting jacket at roof level is in good condition. $ -
AD0000 Air Distribution Fresh Air 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 LS Fresh air for combustion is provided for the Mechanical Room as required.
Page 19 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Air Distribution Fans, centrifugal type 20 1999 3 2018 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.000 # Penn Zephyr transfer fans are located throughout the building. The fans
are in good condition. Fans are controlled by Canarm dial type
thermostats. Fans are rated at approximately 200 L/s each.
$ -
AD0000 Air Distribution Fans, centrifugal type 20 1994 3 2018 Fair Functiona
lity
4-
Recomm
ended
$ 6 $ 6 $ 2.000 # 3 Greenheck upblast exhaust fans are installed on the roof and south
elevation adjacent to the cooling tower.
$ 6
AD0000 Air Distribution Fans, centrifugal type 20 1999 3 2018 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.000 # Penn Zephyr/Carnes transfer fans are located throughout the building.
The fans are in good condition. Fans are controlled by Canarm dial type
thermostats. Fans are rated at approximately 200 L/s each. Model#
V1DK06F3A1CL20S.
$ -
AD0000 Air Distribution Fans, centrifugal type 20 1999 3 2018 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.000 # Standard downblast and upblast type roof exhaust fans are installed. The
fans are manufactured by Penn and are in fair condition. Includes EF-U1
to EF-U12. Fans are rated at 40 to 600 L/s each.
$ -
AD0000 Air Distribution Fans, centrifugal type 20 1979 -17 1998 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.000 # Older Greenheck downblast roof exhaust fans at 1979 Addition. Replace
in short term.
AD0000 Air Distribution Fans, utility type 25 1979 -12 2003 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.300 # Older utility fan at flat roof is in fair condition.
AD0000 Air Distribution Fans, utility type 25 1990 -1 2014 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 17.000 # Older Penn exhaust fan, Delhi (model# 207) exhaust fan for adjacent
rooms, intake air louver (no damper control) and ducting. Allow to verify
all at Garage and add auto CO detection devices.
$ -
AD0000 Air Distribution Fans, downblast 25 1961 -30 1985 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.300 # Older downblast roof fan at flat roof is in poor condition.
AD0000 Air Distribution Fans, centrifugal type 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.300 # Penn fractional horsepower upblast and downblast utility fans, EF-U3, EF-
U4, EF-U6, EF-U7 at flat roof are in fair condition. EF-U1 is located in the
Mechanical Room.
$ -
AD0000 Air Distribution Fans, centrifugal type 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.300 # Penn fractional horsepower upblast and downblast utility fans, EF-U3, EF-
U4, EF-U6, EF-U7 at flat roof are in fair condition. EF-U1 is located in the
Mechanical Room.
$ -
AD0000 Air Distribution Fans, centrifugal type 25 1999 8 2023 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.000 # Penn Fumex sideblast utility fan EF-U5 at Kitchen is in good condition. $ -
AD0000 Air Distribution Fans, centrifugal type 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 18.000 # Gymnasium ceiling fans by Leading Edge are rated at 10000 L/s or
21,190 CFM each.
$ -
AD0000 Air Distribution Fans, destratification 20 2002 6 2021 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.000 # Destratification ceiling fans at Assembly Hall are in good condition. Dial
controls are located at stage.
$ -
AD0000 Air Distribution Fans, through-wall 20 1975 -21 1994 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Older wall exhaust fan at Boiler Room. Allow for replacement and
verification of ventilation performance in immediate term.
AD0000 Air Distribution Fans, through-wall 20 2007 11 2026 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 # Rosemex heater and Carnes 1/20 HP exhaust fan at Gym Storage Room
is in good condition.
$ -
AD0000 Air Distribution Fans, through-wall 20 2007 11 2026 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 1.200 # Carnes 1/20 HP exhaust fan at Elevator Machine Room is in good
condition. Denoted as TF-4.
$ -
AD0000 Air Distribution Ducts 40 2006 30 2045 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 215.000 LS Galvanized ducting is exposed in most locations. No issues noted.
AD0000 Air Distribution Air Terminal Units 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 1.600 # VAV boxes are installed at the supply air ductwork throughout the served
areas of the main floor. The boxes are connected to the BAS. Systems are
operating adequately but further investigation is required; cost carried
under balancing.
$ -
AD0000 Air Distribution Air Terminal Units 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 1.600 # VAV boxes are installed at the supply air ductwork throughout the served
areas of the main floor. The boxes are connected to the BAS. Systems are
operating adequately but further investigation is required; cost carried
under balancing.
$ -
AD0000 Air Distribution Air Terminal Units 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 1.600 # VAV boxes are installed at the supply air ductwork throughout the served
areas of the second floor. The boxes are connected to the BAS. Systems
are operating adequately but further investigation is required; cost carried
under balancing.
$ -
AD0000 Air Distribution Air Outlets and Inlets 30 1999 13 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 30.000 LS Standard 2'x2' supply diffusers, open perimeter and louvered return grilles
are in good condition. Allow for verification of return air quantity and
locations in short term.
$ -
Page 20 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Air Distribution Air Outlets and Inlets 35 2006 25 2040 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 LS The Athletic Centre Mechanical Room is equipped with a fresh air gravity
duct for the combustion air requirements of the gas-fired boilers as
required.
AD0000 Special Exhaust Systems Kitchen Ventilation 25 1999 8 2023 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS Stainless steel exhaust hood in the Kitchen is in good condition. It is
equipped with a grease extractor. Replace in longer term with wall
exhaust fan.
$ -
AD0000 Other HVAC Distribution
Systems
Breechings, Chimneys
and Stacks
30 2006 20 2035 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS Boiler breeching at the Athletic Centre Mechanical Room is constructed
with rated B-vent sections. The ducting is directed vertically off of the three
boilers.
AD0000 Other HVAC Distribution
Systems
Breechings, Chimneys
and Stacks
50 1948 -18 1997 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 85.000 LS Boiler breeching at the main Boiler Room is constructed with welded metal
sections and suspected to be insulated with asbestos materials.
AD0000 Other HVAC Distribution
Systems
Breechings, Chimneys
and Stacks
30 1999 13 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 12.000 LS Boiler breeching and stacks at Mechanical Room are in good condition. $ -
D3050 Terminal and
Packaged UnitsAD0000 Unitary Air Conditioning
Equipment
Split System 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.500 # ICP condenser ((model# NAC036AKA1) is located at the west side of the
building. Serves the Computer Room.
$ -
AD0000 Unitary Air Conditioning
Equipment
Split System 18 2008 10 2025 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.500 # The units were installed over several years starting in 2004 to 2012.
Sanyo (model# CM1972A, C0971, Cl1271 and CL0971), Fujitsu (model#
AOU9RL2), Unitary Products (model# H4DEO24S06A), Carrier (model#
38BNC018301), Daiken (model# C000932), LG (model# LMO240C) and
Mitsubishi (model# MUY-GE09NA and MUZ0FE09NA) condensers are
located at ground and roof levels throughout the site with wall mounted
evaporator sections. Some units have multiple evaporator sections.
Charged with R410A refrigerant and R22 on older units. Consider
replacement with central packaged heating and cooling unit in longer term
with zone control.
$ -
AD0000 Humidifiers 15 1999 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 28.000 # Dri-Steem (model# GTS-150-CAB) is located in the North 1999 Addition at
the 3rd Floor Mechanical Room and serves the air handling unit. The unit
is not installed correctly according to previous reports. Allow to
activate/modify the installation along with commissioning. Serves AHU 1.
AD0000 Humidifiers 15 1999 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 40.000 # Dri-Steem (model# GTS-400-CAB) is located in the North 1999 Addition at
the 3rd Floor Mechanical Room and serves the air handling unit. The unit
is not installed correctly according to previous reports. Allow to
activate/modify the installation along with commissioning. Serves AHU 2
and 3.
AD0000 Humidifiers 15 1999 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 40.000 # Dri-Steem (model# GTS-400-CAB, serial# 1063382-03-01-A) is located in
the Main Mechanical Room. The unit was not in operation at the time of
the inspection.
AD0000 Humidifiers 15 1999 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 28.000 # Dri-Steem (model# GTS-150-CAB, serial# 1063382-04-01-A) is located in
the Main Mechanical Room. This unit is suspended from the ceiling
structure. The unit was not in operation at the time of the inspection.
AD0000 Terminal Heat Transfer
Units
Unit Heaters, electric 25 2006 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.000 # Rosemex (model# H-18), 1/20 HP, 0.94 A electric suspended unit heaters
are in good condition at Athletic Centre service rooms.
$ -
AD0000 Terminal Heat Transfer
Units
Unit Heaters, hot water 25 2006 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.300 # Myson hydronic heaters are located in the stairwells. $ -
AD0000 Terminal Heat Transfer
Units
Force Flow Heaters 30 2006 20 2035 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 # Hot water force flow units, surface or recessed type, are located in the
Athletic Centre Wing.
AD0000 Terminal Heat Transfer
Units
Finned Tube Radiation 40 1994 18 2033 Good Functiona
lity
3-Not Yet
Critical
$ 2 $ 2 $ 2.000 LS 1 Hydronic baseboard heaters are installed in the Change Rooms and
Boardroom.
$ 2
AD0000 Terminal Heat Transfer
Units
Perimeter Radiators 30 1926 -60 1955 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 27.000 LS Perimeter radiators at Barbara Robson Hall are in fair condition.
Page 21 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Terminal Heat Transfer
Units
Perimeter Radiators 30 1926 -60 1955 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 18.000 LS Perimeter radiators at 5th Floor Tower area are in fair condition.
AD0000 Terminal Heat Transfer
Units
Perimeter Radiators 30 2009 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.000 LS Newer radiators are installed along a portion of the 4th Floor corridor at the
Wellness Centre.
AD0000 Terminal Heat Transfer
Units
Perimeter Radiators 30 1926 -60 1955 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 500.000 LS Older radiators are installed at the 400 Level, 300 Level, 200 Level, 100
Level and 000 Level. Allow to replace the heaters in the short term.
AD0000 Terminal Heat Transfer
Units
Radiant Ceiling Panels,
hot water
30 1999 13 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 125.000 LS Airtex Eng-Air (model(HEF-2) ceiling radiant heating panels are installed
along the perimeter exterior walls. The panels and controls are in good
condition. Allow for longer term refurbishment of the panels and
replacement of the valves.
$ -
AD0000 Terminal Heat Transfer
Units
Unit Heaters, hot water 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.000 # Engineered Air (model# H-4) hot water suspended unit heaters are in
good condition at the 1999 Mechanical Room.
$ -
AD0000 Terminal Heat Transfer
Units
Unit Heaters, hot water 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.000 # Engineered Air (model# H-4) hot water suspended unit heaters are in
good condition at the Main Mechanical Room.
$ -
AD0000 Terminal Heat Transfer
Units
Radiant Ceiling Panels,
hot water
30 1999 13 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 95.000 LS Airtex Eng-Air (model(HEF-2) ceiling radiant heating panels are installed
along the perimeter exterior walls. The panels and controls are in good
condition. Allow for longer term refurbishment of the panels and
replacement of the valves.
$ -
AD0000 Terminal Heat Transfer
Units
Force Flow Heaters 30 1999 13 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 # Cabinet force flow unit heaters are located n common areas throughout
the building.
$ -
AD0000 Terminal Heat Transfer
Units
Finned Tube Radiation 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 125.000 LS Finned tube radiation piping is installed at the exterior wall base of the
building in common areas. Sloped top enclosure and pedestal type.
AD0000 Terminal Heat Transfer
Units
Force Flow Heaters 30 1999 13 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 # Hot water force flow units, surface or recessed type, are located in the
1999 Wing.
$ -
AD0000 Terminal Heat Transfer
Units
Finned Tube Radiation 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 135.000 LS Finned tube radiation piping is installed at the exterior wall base of the
building in common areas. Sloped top enclosure and pedestal type.
AD0000 Terminal Heat Transfer
Units
Force Flow Heaters 30 1979 -7 2008 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 # Hot water force flow units, surface or recessed type, are located in the
1979 Wing.
AD0000 Terminal Heat Transfer
Units
Finned Tube Radiation 30 1979 -7 2008 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 135.000 LS Finned tube radiation piping is installed at the exterior wall base of the
building in common areas. Sloped top enclosure and pedestal type.
Approximately 48 runs. Allow for localized valve replacements in short
term.
AD0000 Terminal Heat Transfer
Units
Heating Coils 30 1979 -7 2008 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 30.000 LS Heating coils are located within the ductwork. Replace in longer term.
AD0000 Terminal Heat Transfer
Units
Perimeter Radiators 40 2004 28 2043 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 125.000 LS New radiators, valves and piping were installed in the 3rd Floor Bedrooms,
2nd Floor Corridor, 1st Floor Corridor and IT Offices.
AD0000 Terminal Heat Transfer
Units
Perimeter Radiators 40 1961 -15 2000 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 100.000 LS Older radiators in 2nd Floor Classrooms C49, C48, C47, C46 and 1st
Floor Classrooms B59, B58, B57 and B56 were refurbished in 2004.
D3060 HVAC Instrumentation
and ControlsAD0000 Energy Management and
Conservations Systems
Direct Digital Control
(DDC) Systems
15 2006 5 2020 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 95.000 LS BAS system, monitor and control panels are located at the Level 300
Mechanical Room of the 1999 Wing. Landis & Gyr (model# VE598)
flowrite valves are installed on damper controls are installed.
$ -
AD0000 Energy Management and
Conservations Systems
Direct Digital Control
(DDC) Systems
15 2006 5 2020 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 95.000 LS A web-based building automation system by Empire Controls Ltd. controls
the HVAC system at Athletic Centre. Controls are located at the
Mechanical Room. The system is in good operating condition (controls AC
units, make-up air units, exhaust fans, ventilation, heating and VAV
boxes). Digital thermostats are used for each zoned area.
$ -
AD0000 Energy Management and
Conservations Systems
Direct Digital Control
(DDC) Systems
15 1999 -2 2013 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 45.000 LS A web-based building automation system by Apogee (System 600) is
located in Mechanical Room. The system is in good operating condition
(controls AC units, make-up air units, exhaust fans, ventilation, heating
and VAV boxes). Allow for ventilation review of service rooms in short
term.
AD0000 Other HVAC
Instrumentation and
Controls
20 1999 3 2018 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 LS Landis & Gyr thermostats are installed throughout the building. $ -
D3070 Testing, Adjusting and
BalancingAD0000 Pipe Systems Testing,
Adjusting and Balancing
15 1993 -8 2007 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.000 LS Allow to provide intrusive investigations of piping systems to determine
conditions.
AD0000 Air Systems Testing,
Adjusting and Balancing
8 1993 -15 2000 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 55.000 LS Allow to re-commission the main HVAC equipment to ensure proper air
flows and balance all systems in the short term>
D3090 Other Special HVAC
Systems and
EquipmentD40 Fire Protection $ -
D4010 Sprinklers
AD0000 Wet Pipe 50 1994 28 2043 Good Building
Integrity
3-Not Yet
Critical
$ 100 $ - $ 100.000 LS 1 The building is sprinklered with a wet type system fed from the Facilities
and Services Centre. Supervisory switches are located in service rooms
within the Administration Building.
Page 22 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Wet Pipe 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 1.000 LS Allow for refurbishment of the sprinkler siamese connection in longer term. $ -
AD0000 Wet Pipe 50 2006 40 2055 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 195.000 LS Fully sprinklered facility with 8 sprinkler zones F3, Atrium, F2 Level Atrium,
F2 Level, F1 Level Atrium, F1 Level, B1 Level, B2 Level). Supervised
valves located at the Pool tunnel area. Includes 4" fire line in, butterfly
valve with tamper switch, alarm check valve, piping, heads and siamese
fire department connection at exterior wall. Serviced by M & L Fire and
Burglary Alarms Inc. 905 889-8276.
AD0000 Wet Pipe 50 2006 40 2055 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 LS PVC fire line to black steel fire line at pool tunnel area. No cost carried
within study period.
AD0000 Wet Pipe 50 1983 17 2032 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 400.000 LS Partially sprinklered facility. The Boiler Room, Basement and Boarding
Room Storage Rooms were renovated in 1983 with sprinklers. The main
fire line enters the Shop area. Main black steel fire line is heavily
corroded at entry and active water was noted. Allow for repairs and retrofit
of header, main and valves. Serviced by M-L Fire & Burglary Alarms Ltd.
905 889-8276.
$ -
AD0000 Wet Pipe 50 1999 33 2048 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 200.000 LS Fully sprinklered facility with an 8-zone wet sprinkler system. Supervised
valves are located in the Room 106 and the Carpenter's Shop. Allow for
future valve replacements at main entrances.
D4020 Standpipe
AD0000 Fire Protection
Standpipe
35 1999 18 2033 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 125.000 LS Fire hose cabinets, with 1.5" diameter fire hoses, are provided on each
floor level a the original corridors and boarding floor areas. No adverse
conditions noted and no cost carried through the study period.
$ -
AD0000 Fire Protection
Standpipe
35 1926 -55 1960 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 350.000 LS The centre and south wings should be updated with a standpipe system.
D4030 Fire Protection
SpecialtiesAD0000 Extinguishers and
Cabinets
Extinguisher and
Cabinet
25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 300.000 # Newer ABC type fire extinguishers are installed within recessed steel
cabinets throughout the building. Localized extinguishers are also
installed throughout the building. Monthly inspections by M-L Fire &
Burglary Alarms Ltd.
$ -
D4090 Other Fire Protection
SystemsAD0000 Wet Chemical Kitchen 15 1999 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 7.500 LS Wet chemical fire suppression system is located at the Kitchen ventilation
hood.
AD0000 Dedicated Suppression IT 15 1999 0 2015 Poor Building
Integrity
1-
Currently
Critical
$ 40 $ 40 $ 40.000 LS 1 Allow to add dedicated suppression system to the IT Server Room. $ 40
AD0000 Other Fire Department Access 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS The main fire access route is along the front (west side) of the building.
Access is also provided to the north elevation by the service road. The
south and east elevations are accessed by a designated paved route
along the south property edge with a private hydrant located at the
northeast corner of the Athletic Wing. No allowances are carried to revise
or alter the fire route access.
$ -
AD0000 Other Hydrants 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 12.000 LS Private fire hydrants are located along the north side of the building
towards the ravine and the northeast corner of the Athletic Centre. Public
hydrants are located along Avenue Road. Allow for longer term
refurbishment of the private hydrants.
$ -
D50 Electrical $ -
D5010 Service and
DistributionAD0000 Electrical Service Underground, 3 phase,
4 wire
35 1998 17 2032 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 500.000 LS Underground 13.8 kV electrical service is fed from Rosewell Avenue to the
Hydro Vault Room to a 4-bay , 15-KV S&C Electric switchgear unit with
600A bus .
$ -
AD0000 Electrical Service 3000 A Switchgear Unit 35 1998 17 2032 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 230.000 LS Cutler Hammer switchgear unit rated at 3000A, 347/600V, 3P, 4W located
at the Hydro Vault Room. The distribution section has breakers for the
Junior School Distribution Panel DP-6JA1, Upper School Distribution
Panel DP-6UAB, Upper School Existing Switchboard.
$ -
AD0000 Electrical Service 400 A 40 1961 -15 2000 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 35.000 LS Upper School has a 347/600-Volt, 400-A service from the Main Electrical
Vault.
AD0000 Electrical Service 1200 A 40 1979 3 2018 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 125.000 LS North Wing has a 347/600-Volt, 1200-A service from the Main Electrical
Vault.
$ -
AD0000 Electrical Service 600 A 40 2006 30 2045 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 75.000 LS Athletic Centre has a Cutler Hammer distribution panel 347/600-Volt, 600-
A, 3P, 4W service at the Mezzanine Electrical Room fed from the Main
Electrical Vault. Has digital metering and distribution cell for various
circuits.
AD0000 Secondary Transformers Low Voltage,
Distribution Type
40 1994 18 2033 Good Functiona
lity
3-Not Yet
Critical
$ 4 $ 4 $ 4.000 # 1 A 30 kVA step-up transformer (208-Volt to 600-Volt) is installed in the
Elevator Room.
$ 4
Page 23 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Secondary Transformers 40 1994 18 2033 Good Functiona
lity
3-Not Yet
Critical
$ 15 $ 15 $ 15.000 # 1 A 150 kVA transformer by Hammond, T8, is installed in the Penthouse for
distribution panel RP-PHRA.
$ 15
AD0000 Secondary Transformers Low Voltage,
Distribution Type
40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 # GE Drive Isolation Transformer is rated at 15 KVA and is located at the
Mechanical Room. For inverter system to LP-2JE1.
AD0000 Secondary Transformers Low Voltage,
Distribution Type
40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 13.000 # Cutler Hammer dry type transformer TX-2JA1, located at main Electrical
Room, is rated at 150 KVA. Fed from DP-6JA1.
AD0000 Secondary Transformers Low Voltage,
Distribution Type
40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 # TX-6AB Cutler Hammer dry type transformer, 300 KVA, 600/120/208V,
3P, 4W transformer at Boiler Room is fed from MS-6UBB.
AD0000 Secondary Transformers Low Voltage,
Distribution Type
40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 # 15 KVA Cutler Hammer transformer TX-6UB3 at 1999 Mechanical Room
is in good condition.
AD0000 Secondary Transformers Low Voltage,
Distribution Type
40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 8.500 # 75 KVA Cutler Hammer transformer TX-6UA3 at 1999 Mechanical Room
is in good condition.
AD0000 Secondary Transformers Low Voltage,
Distribution Type
40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 13.000 # Cutler Hammer TX-6UAB, 150 KVA, 600/120/208V, 3P, 4W fed from DP-
6UAB, dry type transformer at Hydro Room.
AD0000 Secondary Transformers Low Voltage,
Distribution Type
40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.000 # Cutler Hammer TX-6UBB, 75 KVA, 600/120/208V, 3P, 4W is fed from DP-
6UAB. Located at Main Electrical Room.
AD0000 Secondary Transformers Low Voltage,
Distribution Type
40 2006 30 2045 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 21.000 # 225 KVA transformer at Athletic Centre: TX-1 by Rex.
AD0000 Secondary Transformers Low Voltage,
Distribution Type
40 2006 30 2045 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 # 30 KVA transformer at Athletic Centre: TX-2 by Rex.
AD0000 Secondary Transformers Low Voltage,
Distribution Type
40 2006 30 2045 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 # 30 KVA transformer at Athletic Centre: TX-3 by Rex.
AD0000 Secondary Transformers Low Voltage,
Distribution Type
40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.500 # 45 KVA transformer at UPS at Boiler Room.
AD0000 Secondary Transformers Low Voltage,
Distribution Type
40 2006 30 2045 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 8.500 # 75 KVA JVC transformer at Boiler Room is for the Emergency Power
circuits.
AD0000 Distribution Panels 600 A 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 12.000 # Cutler Hammer panelboard Type PL4, 600-Amp, 120/208-Volt, 3P, 4W is
located in the Main Electrical Room and is in good condition.
AD0000 Distribution Panels 1200 A 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 # Cutler Hammer panelboard Type PL4, 1200-Amp, 347/600V, 3P, 4W is
located in the Main Electrical Room and is in good condition.
AD0000 Distribution Panels 800 A 40 1994 18 2033 Good Functiona
lity
3-Not Yet
Critical
$ 60 $ 60 $ 20.000 # 3 Federal Pioneer Electric 120/208-Volt distribution panels are installed in
the Telephone Room (DP-NCC) and Penthouse (Panels A, B, and RP-
PHRA).
$ 60
AD0000 Distribution Panels 800 A 40 2006 30 2045 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 16.000 # Cutler Hammer panelboard DP-BB, Type PL4, 800-Amp, 120/208-Volt,
3P, 4W is located in the Mezzanine Electrical Room and is in good
condition. Fed from FX1 at Mezzanine Electrical Room.
AD0000 Branch Circuit
Panelboards
225 A 25 1994 3 2018 Good Functiona
lity
3-Not Yet
Critical
$ 4 $ 4 $ 3.500 # 1 200-Amp, 120/240-Volt, 3 phase, 4 wire, 42 circuit panels are installed in
service rooms. Panels LP-LNA, RP-NRN, RP-NRP (2 panels), and LP-
NEB are located on the first floor adjacent to the Janitor's Room. Panels
RP-2RB (2 panels), RP-2RA, LP-2LA, and LP-2EA are located in the
second floor Utility Room. Panels LP-NBR and RP-BRA are located in the
Telephone Room. Circuits are typically labelled.
$ 4
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.500 # Cutler Hammer panel RP-2JB1, 225-Amp, 120/208-Volt, 3P, 4W, 42
circuit. It is fed from DP-2JA1 and is used for lighting, exhaust fans, etc. It
is in good condition.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.500 # Cutler Hammer panel PP-2JC2, 225-Amp, 120/208-Volt, 3P, 4W, 42
circuit. Located in Room 217 and fed from DP-2JA1. It is in good
condition.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.500 # Cutler Hammer panel PP-2JC1, 225-Amp, 120/208-Volt, 3P, 4W, 42
circuit. Located in Room 126 and fed from DP-2JA1. It is in good
condition.
$ -
Page 24 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.000 # Cutler Hammer panel PP-2JA2, 225-Amp, 120/208-Volt, 3P, 4W, 84
circuit. Located in Room 217 and fed from DP-2JA1. It is in good
condition.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.000 # Cutler Hammer panel PP-2JA1, 225-Amp, 120/208-Volt, 3P, 4W, 84
circuit. Located in Room 126 and fed from DP-2JA1. It is in good
condition.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.000 # Cutler Hammer panel LP-6JA2, 225-Amp, 347/600-Volt, 3P, 4W, 84
circuit. Located in Room 217 and fed from DP-6JA1. It is in good
condition.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.000 # Cutler Hammer panel LP-6JA1, 225-Amp, 347/600-Volt, 3P, 4W, 84
circuit. Fed from DP-6JA1. It is in good condition.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.000 # Cutler Hammer panel RP-2JB1, 225-Amp, 120/208-Volt, 3P, 4W, 84
circuit. Located in Room 129 and fed from DP-2JA1. It is in good
condition.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.000 # Cutler Hammer lighting panel LP-6JE1, 225-Amp, 347/600-Volt, 1P, 2W,
24 circuit. Located in Room 129 and fed from Inverter System. It is in good
condition.
$ -
AD0000 Safety Switches 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 1.400 # Cutler Hammer disconnects, for Transfer and Exhaust Fans and pumps,
throughout the building are in good condition. Replacement not carried
through the study period.
$ -
AD0000 Safety Switches 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 1.400 # Cutler Hammer 30-A disconnect for lift is in good condition. Replacement
not carried through the study period.
$ -
AD0000 Motor Control Centres 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 # Cutler Hammer Freedom Series 2100 motor control centre, MCC #6JA2,
located in the Mechanical Room, is rated for 347/600-Volt, 3P, 3W. It is fed
from DP-6JA1. It is in good condition. Allow for long term replacement.
$ -
AD0000 Motor Control Centres 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 # Cutler Hammer Freedom Series 2100 motor control centre, MCC #6UA3,
located in the 1999 Mechanical Room, is rated for 347/600-Volt, 3P, 3W. It
is fed from DP-6UAB. It is in good condition. Allow for long term
replacement.
$ -
AD0000 Variable Speed Drives 20 2010 14 2029 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 7.500 # Graham 1700 Series variable speed drives (model# 1703AFC25J) are
located in the Main Mechanical Room.
$ -
AD0000 Variable Speed Drives 20 2010 14 2029 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 7.500 # Guardian variable speed drives are located in the Main Mechanical Room.
Used for the air handling units.
$ -
AD0000 Transfer Switches Automatic 25 2005 14 2029 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 29.000 # 600-V, 300-A Cutler Hammer transfer switch is in good condition. $ -
AD0000 Other Contactor 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.000 LS Site lighting contractor, controlled by photo cell, is located at Room 126. $ -
AD0000 Branch Circuit
Panelboards
400A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 # Cutler Hammer panelboard, 400-Amp, 120/208-Volt, 3P, 4W is located at
Main Electrical Vault.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.000 # Cutler Hammer panelboard RP-2UAB, 225-Amp, 120/208-Volt, 3P, 4W is
located at Main Electrical Vault.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 7.000 # Cutler Hammer panelboard LP-6UAB, 225A, 347/600V, 24 circuits, fed
from DP-6UABm is located at Main Electrical Vault.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 2002 11 2026 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.500 # Siemens panel 225-Amp, 120/240-Volt, 3P, 4W, 42 circuit is for the stage
lighting. It is in good condition.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1985 -6 2009 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.500 # Federal Pioneer panel 225-Amp, 120/240-Volt, 3P, 4W, 42 circuit is for the
Laundry Room at the 3rd Floor. It is in good condition.
AD0000 Branch Circuit
Panelboards
250 A 25 2004 13 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 # Siemens panel 250-Amp, 120/240-Volt, 3P, 4W, 30 circuit is for the 3rd
Floor Offices of the 1926 Wing. It is in good condition.
$ -
AD0000 Branch Circuit
Panelboards
100 A 25 2002 11 2026 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Siemens panel 100-Amp, 120/240-Volt, 3P, 4W, 18 circuit is for the 5th
Floor Level lighting and power. It is in good condition.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 2002 11 2026 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.500 # Siemens panel 225-Amp, 120/240-Volt, 3P, 4W, 30 circuit is for the 4th
Floor Level lighting and power. It is in good condition.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 2002 11 2026 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.500 # PP-EA, Siemens panel 225-Amp, 120/240-Volt, 3P, 4W, 30 circuit is for
the Emergency Generator power, located at the Boiler Room. It is in good
condition. Includes 600V disconnect switch and splitter.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 2002 11 2026 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.500 # Siemens panel 225-Amp, 120/240-Volt, 3P, 4W, 42 circuit is for the UPS
back-up power, located at the Boiler Room.
$ -
Page 25 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Branch Circuit
Panelboards
800 A 25 2002 11 2026 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 # Siemens power panel B, 800-Amp, 120/208-Volt, 3P, 4W, 50 circuit is fed
from main distribution panel and serves the south wing pool, gymnasium,
change rooms, main school centre power risers, south wing bedrooms,
portable, Staff House, Art Room, Hub Room. Poor identification of
circuits noted.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 2002 11 2026 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.500 # Siemens power panel A, 225-Amp, 120/208-Volt, 3P, 4W, 42 circuit is fed
from main distribution panel.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 2002 11 2026 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.500 # Siemens power panel B 225-Amp, 120/208-Volt, 3P, 4W, 30 circuit is fed
from main distribution panel.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 2002 11 2026 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.500 # Siemens power panel C, 225-Amp, 120/208-Volt, 3P, 4W, 42 circuit is fed
from main distribution panel.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 2002 11 2026 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.500 # Siemens power panel D, 225-Amp, 120/208-Volt, 3P, 4W, 42 circuit is fed
from main distribution panel.
$ -
AD0000 Branch Circuit
Panelboards
100 A 25 2006 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.000 # Cutler Hammer RP-B1 power panel D, 100-Amp, 120/208-Volt, 3P, 4W, 24
circuit is fed from DP-BB. Located in Pool Mechanical Room.
$ -
AD0000 Branch Circuit
Panelboards
250 A 25 2006 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 # Cutler Hammer 250-A, PP-EA, 600V, 3P, 3W, 66 circuit for emergency
power at Mezzanine Electrical Room. Fused at 100-A. Serves
transformers and pumps.
$ -
AD0000 Branch Circuit
Panelboards
100A 25 2006 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.000 # Cutler Hammer 100-A, RP-B4, 3 P, 4W, 42 circuit at Mezzanine Electrical
Room.
$ -
AD0000 Branch Circuit
Panelboards
25 2006 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 # Cutler Hammer RP-B6, 84 circuit at Mezzanine Electrical Room serves the
main pool lighting, basement lighting, first floor lighting, mezzanine floor
lighting.
$ -
AD0000 Branch Circuit
Panelboards
100A 25 2006 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.000 # Cutler Hammer 100-A, LP-EB, 42 circuit at Mezzanine Electrical Room
serves the BAS, Data and Pool.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 2006 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Siemens power panel South Wing Level B, 225-Amp, 120/208-Volt, 3P,
4W, 30 circuit is fed from Boiler Room Mezzanine.
$ -
AD0000 Branch Circuit
Panelboards
100 A 25 2010 19 2034 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Square D power panel South Wing Level B, 100-Amp, 120/208-Volt, 3P,
4W, 30 circuit is located in the Slop Sink Room.
AD0000 Branch Circuit
Panelboards
225 A 25 2010 19 2034 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Panelboard at Room B39 is in fair condition.
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Panelboard at Room C27 is LP-6UA2 , 225A, 84 circuits, 347/600V fed
from DP-6UAB.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Panelboard at Room C27 is RP-2UA2 , 225A, 120/208V, 84 circuit fed
from DP-2UAB.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Panelboard at Room B34 is LP-6UA1, 347/600V fed from DP-6UAB. $ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Panelboard at Room B34 is RP-2UA1, 120/208V fed from DP-2UAB. $ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Panelboard at underside of service stair RP-2UB2, 120/208V fed from
SP6-UAB.
$ -
Page 26 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.500 # Panelboard at 3rd Floor Mechanical Room RP-2UA3, 120/208V, 42-circuit
is fed from TX-6UB3.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Panelboard at Theatre Sound Room RP-2UB3, 120/208V fed from SP-
6UAB.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Panelboard at 3rd Floor is for the south wing bedrooms: Siemens 225A,
120/240V, 3P, 4w fed from Boiler Room Mezzanine.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Panelboard at 2nd Floor is for the south wing Classrooms: Siemens
225A, 120/240V, 3P, 4w fed from Boiler Room Mezzanine.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Panelboard at 2nd Floor is for the south wing IT Office: Siemens 225A,
120/240V, 3P, 4w fed from Boiler Room Mezzanine.
$ -
AD0000 Branch Circuit
Panelboards
250 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Panelboard at 3rd Floor Offices: Siemens 250A, 120/208V, 3P, 4w. $ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Panelboard at B48 Office area: Siemens 225A RP-2UG2, 120/208V, 3P,
4w.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 2003 12 2027 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Panelboard at C34 Office area: Siemens 225A, 120/208V, 3P, 4w., 24-
circuit.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Panelboard at Level 100 Hall: Siemens 225A RP-2UG2, 120/240V, 3P,
4w.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Panelboard at Level 100 Hall: Siemens 225A, 120/240V, 3P, 4w, 24
circuit.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Panelboard at Level 100 Hall: Panel RB 2UJ1, 225A, 120/208V, 3P, 4w,
fed from stage circuit.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Panelboard at Garage: RP-2UH1 , 225A, 120/208V, 3P,4W, 42-circuit fed
from Boiler House Mezzanine. Complete with Tork timer for exterior
lighting.
$ -
AD0000 Safety Switches 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Moisture proof disconnects are installed at the Kitchen areas. $ -
AD0000 Safety Switches 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 8.000 LS Various rated disconnects at service rooms are in good condition. $ -
AD0000 Safety Switches 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 8.000 LS Various rated disconnects at service rooms are in good condition. $ -
AD0000 Safety Switches 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 8.000 LS Various rated disconnects at service rooms are in good condition. $ -
AD0000 Safety Switches 25 2002 11 2026 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 8.000 LS Various disconnects at Boiler Room are in fair-to-good condition. $ -
-2016 Building
Integrity
1-
Currently
Critical
Page 27 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Safety Switches 25 2002 11 2026 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 8.000 LS Various disconnects at North Mechanical Room Level A are in fair-to-good
condition.
$ -
AD0000 Safety Switches 25 2006 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS Various disconnects at Service Rooms including the Elevator Machine
Room, Pool Mechanical Room.
$ -
AD0000 Safety Switches 25 2006 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS Various disconnects at Service Rooms including the Elevator Machine
Room, Pool Mechanical Room.
$ -
AD0000 Other Thermography 5 1993 -18 1997 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 10.000 LS Allow for thermography scan in short term to determine condition of all
equipment. Short term replacement years may be altered.
D5020 Lighting and Branch
WiringAD0000 Interior Lighting Fluorescent Fixtures 30 1994 8 2023 Fair Functiona
lity
4-
Recomm
ended
$ 160 $ 160 $ 0.400 # 400 Fluorescent lighting is installed throughout. Lighting includes potlights and
wall mounted fixtures with compact fluorescent lamping and T8
fluorescent light fixtures. Vapour proof fixtures are installed in the Change
Rooms. Parabolic diffusers are installed in office areas.
$ 160
AD0000 Interior Lighting LED Fixtures 25 2010 19 2034 Good Functiona
lity
4-
Recomm
ended
$ 5 $ - $ 0.500 # 10 LED pot lights are installed in the Boardroom.
AD0000 Interior Lighting Fluorescent Fixtures 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.500 LS LED track lighting fixture at Open Studio is in good condition. $ -
AD0000 Interior Lighting Fluorescent Fixtures 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.750 # 1'x4', double T8 fluorescent lamped, suspended light fixtures are located
throughout the gymnasium.
$ -
AD0000 Interior Lighting Metal Halide 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.550 LS 100-W metal halide fixtures at main foyer are in good condition. $ -
AD0000 Interior Lighting Metal Halide 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.750 LS 400-W metal halide fixtures at Library are in good condition. $ -
AD0000 Interior Lighting Halogen Fixtures 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.750 LS Par halogen lamped suspended fixtures at Library are in good condition. $ -
AD0000 Interior Lighting Halogen Fixtures 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.500 LS Par halogen lamped recessed fixtures at main foyer area at Library are in
good condition.
$ -
AD0000 Interior Lighting 25 2006 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 300.000 LS Lighting fixtures for Athletic Centre are in good condition. Includes T8
fixtures in foyers and halls and F32 T6 4' strip with wire cage at Pool
tunnel area.
$ -
AD0000 Interior Lighting 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 200.000 LS Lighting fixtures for Centre Wing are in good condition. Traditional style
fixtures. Dorms use 1'x4' T8 lamped surface mounted fluorescent fixtures
$ -
AD0000 Interior Lighting 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 120.000 LS Lighting fixtures for South Wing are in good condition. Typically 2'x4'
fluorescent type fixtures, 120V, 160W, 4-lamp, T8.
$ -
AD0000 Interior Lighting 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 125.000 LS Lighting fixtures for North Wing are in good condition. Includes decorative
and specialty fixtures,
$ -
AD0000 Interior Lighting 25 2006 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 29.000 LS Lighting fixtures for the Pool are in good condition. Includes Oaktronics
metal halide and Portfolio C16032 Series hanging CFL fixtures. Includes
22 uplights, 12 wall sconces and 8 CFL type.
$ -
AD0000 Interior Lighting 25 2006 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 35.000 LS Lighting fixtures (58) for the double and single Gyms are in good condition.
The fixtures are high intensity TM9 metal halide, indirect with pulse start
lamp ballasts and 400-W lamping. In single and dual head format.
$ -
Page 28 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Interior Lighting 25 2006 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 35.000 LS Lighting fixtures (58) for the double and single Gyms are in good condition.
The fixtures are high intensity TM9 metal halide, indirect with pulse start
lamp ballasts and 400-W lamping. In single and dual head format.
$ -
AD0000 Interior Lighting 25 2006 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.000 LS Cube wall mounted T8 fluorescent fixtures are installed in the northwest
stairwell.
$ -
AD0000 Interior Lighting 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.000 LS Magnetek 400W ballasts for metal halide fixtures for Theatre work lights
are in good condition.
$ -
AD0000 Interior Lighting 25 1926 -65 1950 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 40.000 LS 6 large suspended lighting fixtures, with triple pendent fixtures, for the
Barbara Robson Assembly Hall are in good condition. The suspended
fixtures have historical significance. Replacement is not anticipated.
AD0000 Interior Lighting 25 1979 -12 2003 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.000 LS Par halogen lighting fixtures and stage lighting are in good condition.
Includes tracking and blackout curtains and wall mounted metal halide
fixtures. Barbara Robson Hall.
AD0000 Interior Lighting Light Dimming System 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.500 # Stage-Scope dimming system by Stagecraft Industries and NSI
commercial dimmer pack are located at the Gymnasium .
$ -
AD0000 Interior Lighting Light Dimming System 20 2006 10 2025 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 22.000 # Low voltage lighting programmable controllers are used for the exterior
lighting and pool lighting systems. The controllers are in good condition.
Relay panels are located in Mezzanine Electrical Room.
$ -
AD0000 Interior Lighting Light Dimming System 20 2006 10 2025 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 18.000 # Lumitrol theatre lighting dimming system (hanging cord patch panel) and
Ash-Stevenson Tec 8112 preset dimmer unit.
$ -
AD0000 Other Switches and
Receptacles
25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Decora decorative switches and standard three-prong receptacles are in
good condition. GFI receptacles are installed near sink locations as
required.
$ -
AD0000 Other Switches and
Receptacles
25 1979 -12 2003 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 LS Lighting switch panel for Assembly Hall, at Stage, is in need of updating.
AD0000 Solar Panels Rooftop Solar Panels 20 2013 17 2032 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 80.000 LS Rooftop solar panels were installed on the 1999 wing in 2013. Panels are
by Eclipsall (model# NRG60-250P) with rated STC power of 250 W.
System provides power for auxiliary panels located in the Athletic Wing
Mechanical Room. SMA Sunny Boy (model# SB600oUS-11) utility
interactive 1-phase inverter has a 6000W AC rating.
$ -
D5030 Communication and
SecurityAD0000 Detection and Fire
Alarms
25 1994 3 2018 Fair Life
Safety
4-
Recomm
ended
$ 25 $ 25 $ 25.000 LS 1 Simplex 4602 annunciator panel located at the entrance. The Simplex
4100 fire alarm control panel is located in the Security Office. Heat and
smoke detectors, alarm bells, and pull stations are located throughout.
Strobe fixtures are installed in the Change Rooms and Penthouse. Pull
stations are installed above the maximum height of 1200mm (47") for
accessibility. A Notifier annunciator panel is also located in the Security
Office and serves the six adjacent buildings.
$ 25
AD0000 Detection and Fire
Alarms
25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 118.000 LS Building annunciator and zone plan at main vestibule are in good
condition.
$ -
AD0000 Detection and Fire
Alarms
Fire Safety Plan 15 2014 13 2028 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.500 LS Upper School Fire Safety Plan is under review and editing by
Management (September 2014). Allowances are carried for updating the
plan for Fire Department approval.
$ -
AD0000 Detection and Fire
Alarms
Fire Safety Plan 15 2014 13 2028 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 LS Fire Safety Plan was reviewed at the Facility Office. The plan requires
updating.
$ -
AD0000 Security Access and
Surveillance
CCTV or Video
Surveillance Systems
15 2014 13 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 52.000 LS The existing exterior video surveillance system is being upgraded. New
cameras were installed at the South House and Junior School and Athletic
Centre main door.
$ -
AD0000 Security Access and
Surveillance
CCTV or Video
Surveillance Systems
15 2015 14 2029 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 120.000 LS The school was upgraded with new digital cameras with IP based system
and 30-day recording back-up storage.
$ -
AD0000 Security Access and
Surveillance
Electronic Access
Controls
15 2015 14 2029 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 35.000 LS EAC system added for shipping/receiving door, the IT Server Room and a
card reader at Athletic Centre-to-School and .
$ -
Page 29 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Security Access and
Surveillance
Electronic Access
Controls
15 2015 14 2029 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.500 LS EAC system added to house. $ -
AD0000 Security Access and
Surveillance
Electronic Access
Controls
15 2005 4 2019 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Keyscan Access Control Systems are installed. $ -
AD0000 Security Access and
Surveillance
Electronic Access
Controls
15 2006 5 2020 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Keyscan Access Control Systems are installed throughout the service
rooms.
$ -
AD0000 Security Access and
Surveillance
Plans 15 2015 14 2029 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 60.000 LS Business Continuity and Disaster Recovery Plan were implemented as
part of Risk Management.
$ -
AD0000 Security Access and
Surveillance
Other 15 1999 -2 2013 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 40.000 LS Intrusion detection system updated to include recessed contacts with
glass break sensors in first floor areas. Also add panic alarm buttons in
common hall areas.
AD0000 Security Access and
Surveillance
Other 15 1999 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 LS Aiphone door entry call station is installed at the Main Office.
AD0000 Sound Systems 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.000 LS Valcom ceiling speakers are in good condition. $ -
AD0000 Other Communication
and Security Systems
Emergency and Exit
Lighting
20 2010 14 2029 Good Functiona
lity
4-
Recomm
ended
$ 6 $ 6 $ 0.400 # 15 LED exit signage is installed throughout. $ 6
AD0000 Other Communication
and Security Systems
Exit Lighting 20 1975 -21 1994 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.300 # Illuminated exit signage is in fair condition. Fixtures are incandescent type.
Allow to update to LED type.
AD0000 Other Communication
and Security Systems
Exit Lighting 20 2006 10 2025 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.300 # Beghelli illuminated exit signage is in good condition. $ -
AD0000 Other Communication
and Security Systems
Emergency Lighting 20 1999 3 2018 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.350 # Plug-in, battery operated Lumacell fixtures are installed throughout the
building including the Assembly Hall.
$ -
AD0000 Other Communication
and Security Systems
Emergency Lighting 20 1999 3 2018 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.600 # Plug-in, battery operated heads are located throughout the hall with Dual
Lite battery units throughout the addition.
$ -
AD0000 Other Communication
and Security Systems
20 1999 3 2018 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 40.000 LS Communication and data wiring, hardware and racking are in good
condition. Includes APC (Smart UPS RT 3000) back-up unit.
$ -
AD0000 Other Communication
and Security Systems
35 1999 18 2033 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.000 LS Telephone backbone and wiring are in good condition. $ -
AD0000 Other Communication
and Security Systems
35 2006 25 2040 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.000 LS Telephone backbone and wiring are in good condition at Mezzanine IT
Room.
D5090 Other Electrical
SystemsAD0000 UPS 20 2009 13 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 40.000 LS Eaton Powerware UPS (model# 9355) is rated at 30 KVA. $ -
AD0000 Packaged Engine
Generator
25 2006 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 175.000 LS Packaged Generac generator (model# S686670100) is rated for 250 kVA
for the Athletic Centre. Access to the unit was not available. Allow to
include circuit for Food Service refrigeration in the immediate term.
$ -
AD0000 Packaged Engine
Generator
25 1999 8 2023 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 525.000 LS The Junior School has no emergency generator. Allow for adding an
emergency generator and updating/expanding the IT capacity.
$ -
E EQUIPMENT AND
FURNISHING
$ - $ - $ - $ 18 $ - $ - $ - $ - $ - $ 10 $ - $ - $ - $ - $ - $ - $ - $ - $ - $ -
E10 Equipment $ -
Page 30 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
E1010 Commercial
Equipment
E1090 Other Equipment
AD0000 Other 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.000 LS Ceiling mounted projectors are located in each Classroom. The Copy
Room has a Sharp copier. Items are considered operational items and
are not included.
$ -
AD0000 Exterior Furnishings 25 1974 2 2017 Fair Accessibil
ity
4-
Recomm
ended
$ 2 $ 2 $ 2.000 LS 1 No bench is provided at the main entrance, allow to provide. $ 2
E20 Furnishings $ -
E2010 Fixed Furnishings
AD0000 Fixed Casework Cabinetry 25 2006 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 LS Built-in display cases at the Gymnasium corridor are in good condition. $ -
AD0000 Fixed Casework Cabinetry 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 12.000 LS Wood framed display cabinets at the Main Floor corridor are in good
condition.
$ -
AD0000 Fixed Casework Cabinetry 30 1994 8 2023 Fair Appearan
ce
4-
Recomm
ended
$ 10 $ 10 $ 10.000 LS 1 Laminate cabinetry is installed in the Cafeteria, Kitchenettes, and office
areas. Cabinetry is functional but dated.
$ 10
AD0000 Fixed Casework Cabinetry 30 1994 2 2017 Fair Accessibil
ity
5-Does
Not Meet
Current
Code
$ 10 $ 10 $ 10.000 LS 1 Laminate and wood framed reception desk with glazing is in fair condition
though dated. The desk is not lowered for barrier-free access as required.
Allow for short term replacement or refurbishment.
$ 10
AD0000 Window Treatment 20 1999 3 2018 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Sunproject fabric roller type blinds are installed in the Classrooms and
other support areas. All treatments are in good condition. Replacement
carried in the longer term.
$ -
AD0000 Fixed Casework Laminate Cabinetry and
Countertops
25 1994 2 2017 Fair Appearan
ce
3-Not Yet
Critical
$ 6 $ 6 $ 6.000 LS 1 Laminate countertops in the Change Rooms and Washrooms are in fair
condition with localized deterioration. The countertop in the Cafeteria is
worn. Counters are dated but otherwise functional. Repairs where
delamination is occurring are considered maintenance.
$ 6
AD0000 Fixed Casework Laminate Cabinetry and
Countertops
25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 250.000 LS Laminate wall mounted cabinetry, shelving and countertops are in good
condition.
$ -
AD0000 Fixed Casework Laminate Cabinetry and
Countertops
25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 55.000 LS Laminate wood desks and counters at Main Office are in good condition. $ -
AD0000 Fixed Casework Laminate Cabinetry and
Countertops
25 1999 8 2023 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 900.000 LS Laminate wall mounted upper/lower cabinetry and countertops are in
fair=to-good condition.
$ -
E2020 Movable Furnishings
F SPECIAL
CONSTRUCTION AND
DEMOLITION
$ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ -
F10 Special Construction $ -
F1010 Special Structures
F1020 Integrated
Construction
F1030 Special Construction
F1040 Special Facilities
F1050 Special Controls and
InstrumentationAD0000 Other Special Controls
and Instrumentation
CO Detection 12 2006 2 2017 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 7.000 LS Kidde Night Hawk plug-in smoke detectors are located at the Athletic
Centre Mechanical Room. Allow for hard wired system and detectors.
$ -
AD0000 Other Special Controls
and Instrumentation
CO Detection 12 2006 2 2017 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 10.000 LS Kidde Night Hawk plug-in smoke detectors are located at the Main Boiler
Room. Allow for hard wired system and detectors.
$ -
F20 Selective Building
Demolition
$ -
F2010 Building Elements
Demolition
F2020 Hazardous
Components
AbatementAD0000 Hazardous Substance
Report
10 1993 -13 2002 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Allow to update Asbestos Survey Plan and provide a complete Designated
Substance Report. Some older incandescent fixtures have asbestos heat
shields.
G SITEWORK $ 4 $ 5 $ - $ - $ 40 $ - $ 8,762 $ - $ 6 $ 26 $ - $ - $ - $ - $ 67,550 $ - $ - $ - $ - $ -
G10 Site Preparation $ -
Page 31 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
G1010 Site Clearing
G1020 Site Demolition and
Relocation
G1030 Earthwork
G1040 Hazardous Earth
Remediation
G20 Site Improvements $ -
G2010 Roads
AD0000 Flexible Roadway
Pavement
Asphaltic Concrete 18 1999 1 2016 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.009 sf South and east asphalt paved roadway is in fair condition. Fatigue
cracking was noted. Allow for short term repairs.
$ -
AD0000 Flexible Roadway
Pavement
Asphaltic Concrete 18 2006 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.090 sf Asphalt surfaced drop-off semi-circular drive at west main entrance is in
good condition.
$ -
AD0000 Flexible Roadway
Pavement
Asphaltic Concrete 18 1999 1 2016 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.090 sf West drive is in fair condition. Allow for replacement in the mid-term. $ -
G2020 Parking Lots
AD0000 Flexible Parking Lot
Pavement
Asphaltic Concrete 18 1994 5 2020 Fair Functiona
lity
3-Not Yet
Critical
$ 5 $ 8,712 $ 8,717 $ 0.090 sf 96800 North parking lot and entrances drives from Old Finch Avenue are paved
with asphaltic concrete. The surface is in fair condition. Unit pavers are
installed in front of the main entrance. Localized settlement and fatigue
cracking was noted. Allow for short term repairs and then replacement.
$ 5 $ 8,712
AD0000 Unit Pavers Parking Lot 35 1999 18 2033 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.013 sf Permeable unit pavers at the Junior School diagonal parking stalls are in
fair condition. Allow for short term repairs and long term replacement.
$ -
AD0000 Unit Pavers Drive 35 1999 18 2033 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.013 sf Unit pavers are installed at the main drive area. The pavers are settled
and rutted. Allow for minor repairs in short term.
$ -
AD0000 Unit Pavers 40 1999 23 2038 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.013 sf Permeable unit pavers along the west drive are in fair condition. Allow for
long term replacement.
AD0000 Flexible Parking Lot
Pavement
Asphaltic Concrete 25 1978 -13 2002 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.009 sf Asphalt parking lot at west tier of main parking lot is in fair condition with
moderate longitudinal cracking, fatigue cracking, and settlement at the
catch basins. Settlement at the drive between the parking lot and main
entrance circle was also noted. Allow for short term repairs and
replacement in the longer term.
AD0000 Flexible Parking Lot
Pavement
Asphaltic Concrete 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.011 sf Asphalt parking lot at east tier of main parking lot, drive aisle and service
area are in good condition. Combination of heavy and light duty
pavements. Allow for minor crack repairs in short term.
$ -
AD0000 Flexible Parking Lot
Pavement
Asphaltic Concrete 18 1999 1 2016 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.009 sf Asphalt turn circle at main entrance is in good condition. $ -
AD0000 Flexible Parking Lot
Pavement
Concrete 25 1999 8 2023 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.025 sf Poured concrete at northwest garbage area is in fair condition with minor
staining. Allow for long term replacement.
$ -
AD0000 Parking Lot Curbs and
Gutters
Poured Concrete 30 1999 5 2020 Fair Functiona
lity
3-Not Yet
Critical
$ 50 $ 50 $ 0.025 lf 2000 Parking lot is partially outlined by poured concrete curbs. Curbs are in fair
condition overall with minor wear and cracking throughout. Allow for
replacement with asphalt paving.
$ 50
AD0000 Parking Lot Curbs and
Gutters
Poured Concrete 30 1999 13 2028 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.025 lf Poured concrete curbs at the Upper School parking lot and drives are in
fair condition. Localized cracking was noted. Allow for short term repairs
and long term replacement. Curbs are not installed along the sides of the
parking lots and drives that are adjacent to the ravine.
$ -
G2030 Pedestrian Paving
AD0000 Pedestrian Unit Pavers Brick Pavers 30 1994 8 2023 Good Functiona
lity
3-Not Yet
Critical
$ 4 $ 26 $ 30 $ 0.013 sf 2000 Unit pavers are installed on the north elevation at the entrances.
Settlement was noted at curb edges, creating a trip hazard. Re-levelling as
needed is considered maintenance.
$ 4 $ 26
Page 32 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Pedestrian Unit Pavers Brick Pavers 30 2009 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.025 sf Stone sidewalk at the main entrance is in fair condition. Settlement at the
curb has created a trip edge. Allow for immediate repairs. Stone walkways
are also installed at the Athletic Centre entrance.
AD0000 Rigid Pedestrian
Pavement
Poured Concrete 30 1999 13 2028 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.020 sf Poured concrete sidewalk at the main entrance circle is in fair condition.
Allow for long term repairs.
$ -
AD0000 Rigid Pedestrian
Pavement
Poured Concrete 30 1999 13 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.016 sf Poured concrete sidewalk at the parking lot and main entrance to the
Junior School is in good condition. A newer section at the main entrance
drive was noted. Allow for long term replacement.
$ -
AD0000 Rigid Pedestrian
Pavement
Poured Concrete with
Wood
10 1999 -7 2008 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.010 sf Poured concrete sidewalk with wood slat inlay sections at the rear patio
areas of the Junior School is in fair condition with localized damage and
tripping hazards. Includes precast concrete patio slabs at rear walk also.
Allow for repairs every 10 years.
AD0000 Rigid Pedestrian
Pavement
Asphaltic Concrete 20 1961 -35 1980 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.007 sf Older asphalt path at west side of main building is in poor condition with
cracking and significant cross slope.
AD0000 Rigid Pedestrian
Pavement
Asphaltic Concrete 20 1999 3 2018 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.007 sf Asphalt walkways on the south and west sides of the Upper School and
Junior School are in fair condition. Minor fatigue cracking was noted,
particularly along the edges. Allow for replacement in the mid-term.
$ -
AD0000 Loose Surfacing Screenings 12 1999 -5 2010 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 LS Screening surfaced pathways between Upper School and Junior School
are in good condition. Allow for resurfacing and top up only.
AD0000 Paving Stone 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.500 LS Flagstone inlay at main entrance of school and stair landings is in good
condition. Allow for long term replacement/modifications.
$ -
AD0000 Exterior Steps and
Ramps
Stone 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.000 LS Flagstone stair at west elevation of main building is in good condition.
Allow for long term replacement/modifications.
$ -
AD0000 Exterior Steps and
Ramps
Poured Concrete 30 1980 -6 2009 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 10.000 LS Concrete stairs at walkway under main entrance are in fair condition with
minor wear. Allow for long term repairs/modifications.
AD0000 Exterior Steps and
Ramps
Poured Concrete 30 1990 4 2019 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 10.000 LS Concrete stairs to lower level at service wing are in good condition. Exit
19.
$ -
AD0000 Exterior Steps and
Ramps
Steel 30 1980 -6 2009 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 12.000 LS Steel staircase at north quad area is in fair condition with corrosion.
Refurbish in longer term.
AD0000 Exterior Steps and
Ramps
Concrete Unit Pavers 30 1999 13 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 LS The main entrance stairs are in good condition with no damage. $ -
AD0000 Exterior Steps and
Ramps
Unit Pavers 30 1999 13 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 7.000 LS Unit paver stairs at west side of Main Building to Avenue Road are in good
condition.
$ -
AD0000 Exterior Steps and
Ramps
Unit Pavers 30 1999 13 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.000 LS Unit paver stairs at south stair to play field, with wood risers, are in good
condition. Minor settlement considered maintenance.
$ -
AD0000 Exterior Steps and
Ramps
Poured Concrete 30 2006 20 2035 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 75.000 LS Concrete stairs and ramp to the Athletic Centre entrances are in good
condition. Minor cracking and nosing deterioration was noted on the south
stair. Allow for short term repairs at the south stair and long term
modifications. Includes steel railings and guards.
AD0000 Exterior Steps and
Ramps
Poured Concrete 30 1999 13 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 12.000 LS Concrete exterior stair is in good condition. $ -
Page 33 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Pedestrian Bridges 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 125.000 LS The prefabricated steel bridge, concrete abutments and metal deck cover
at the ravine are in good condition. Allow to refurbish in mid-term.
G2040 Site Development
AD0000 Street Furnishings Miscellaneous 18 1999 1 2016 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.000 LS Steel benches at main entrance, wood benches at west elevation along
with PVC receptacles.
$ -
AD0000 Retaining Walls Poured Concrete 35 1999 18 2033 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS Poured concrete retaining/seating wall at north quad is in good condition.
No allowances carried through the study period.
$ -
AD0000 Retaining Walls Precast Concrete Unit 35 1994 13 2028 Good Building
Integrity
4-
Recomm
ended
$ 67,500 $ 67,500 $ 135.000 lf 500 Precast retaining wall with centrally located stair divides the upper and
lower parking areas and at the Site Control entrance. The wall is in good
condition. Past repairs were noted to nosings on the stair.
$ 67,500
AD0000 Other Playground 15 2000 -1 2014 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 19.000 LS Henderson prefabricated PVC (model# 2262) and prefinished steel
playground equipment/apparatus is in good condition.
$ -
AD0000 Other Shed 15 2009 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.000 LS Prefabricated wood shed at Service area is in good condition. $ -
AD0000 Other Shed 15 2000 -1 2014 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.000 LS Prefabricated wood shed at Tennis Court area is in good condition. $ -
AD0000 Other Playground 15 1999 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 19.000 LS Prefabricated PVC and prefinished steel playground equipment/apparatus
is in fair condition.
AD0000 Other Playground Surfacing 15 1999 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 LS Rubberized surfacing is in fair condition with localized damage. Replace
with playground apparatus.
AD0000 Other Sport Apparatus 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.500 LS Two tubular steel framed soccer nets are located at the north field. $ -
AD0000 Other Sport Apparatus 25 2004 13 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 10.000 LS Two tubular steel framed soccer nets are located at the east field. Netted
back stops are also provided.
$ -
AD0000 Fencing Chain Link 25 1990 -1 2014 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.045 lf Chain link fencing at the south tennis courts in poor condition. Corrosion
was noted and posts are unstable. Allow for short term replacement.
$ -
AD0000 Fencing Chain Link 25 1961 -30 1985 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.025 lf Chain link fencing at property line is in fair condition with damaged
sections.
AD0000 Fencing Ornamental 25 2006 15 2030 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.040 lf Metal picket fence along west lot line is in good condition overall. Newer
sections were noted. Allow for long term replacement.
$ -
AD0000 Fencing Ornamental 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.040 lf Prefinished metal picket fence along playground area is in good condition
overall with minor corrosion. Allow for long term replacement.
$ -
AD0000 Fencing Chain Link 25 1979 -12 2003 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.028 lf Older 6' high chain link fencing along north lot line is in fair condition.
AD0000 Signs General Signage 20 2013 17 2032 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 8.000 LS Metal framed, core board site signage on Avenue Road is in good
condition. Allow for replacement in the mid-term. Also includes second
directional signage board.
$ -
Page 34 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Signs General Signage 20 2013 17 2032 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.000 LS Metal framed scoreboard site signage on Rosewell Avenue is in good
condition. Allow for replacement in the longer term.
$ -
AD0000 Other Guards and Handrails 35 1994 13 2028 Good Functiona
lity
4-
Recomm
ended
$ 50 $ 50 $ 0.100 lf 500 Galvanized steel guards and handrails are installed at the retaining wall
and stair.
$ 50
AD0000 Other Guards and Handrails 35 1926 -55 1960 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 10.000 LS No handrails or guards are installed on concrete stairs under the main
entrance. Allow for immediate installation.
AD0000 Other Guards and Handrails 35 2006 25 2040 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS Galvanized steel guard at stair to staff room and at Athletic Centre ramps
and stairs are in good condition. Allow for long term replacement.
AD0000 Other Guards and Handrails 35 1999 18 2033 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 LS Galvanized steel handrails at the west stair at the Junior School are in
good condition. Allow for long term replacement.
$ -
AD0000 Other Guards and Handrails 30 1999 13 1 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.000 LS The stainless steel tubular handrails at main west entrance do not extend
beyond the first riser as per standard practice. Replacement is carried in
short term to correct issue.
$ -
AD0000 Other Out Building 20 2005 9 2024 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 LS Small PVC storage shed at Junior School is in good condition. $ -
AD0000 Other Out Building 25 2014 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.000 LS A prefabricated shed by NRB Inc. is located on the east elevation. The
shed is wood framed with metal siding, two metal doors, and a sloped
roof. The shed is not heated. A 125-Amp, 120/240-Volt, 20 circuit panel by
Eaton is installed. The panel is fed from Panel B in the Boiler Room. The
interior is illuminated by a compact fluorescent light fixture. A GFI
receptacle is located on the exterior. The shed is vented. Allow for long
AD0000 Other Out Building 30 2012 26 2041 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 10.000 LS The Arts Portable is a prefabricated structure with wood framing
(presumed), metal siding, aluminum framed, double glazed windows,
aluminum framed door with double glazing by Windspec, and a metal door
with glazing. Interior finishes consist of vinyl sheet flooring, gypsum wall
board, and lay-in ceiling tiles. A 125-Amp, 120/240-Volt, 20 circuit panel by
Eaton and fluorescent light fixtures are installed. Soffit mounted fixtures
are installed at the exterior. Pull stations, alarm bell, and smoke detector
are installed. Emergency light fixtures, exit signage, and panic bar door
hardware are not installed. The Portable is heated with a packaged unit
complete with Change Air digital thermostat. Standard diffusers are
installed at the ceiling. The building is accessed by two wood stairs. Minor
damage was noted to the metal siding due to heaving of the tennis court
surface. Also has a green roof assembly.
AD0000 Other Covered Canopies 18 2010 12 2027 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.000 LS Cloth covered, metal framed, canopies are in good condition near the Art
House.
$ -
AD0000 Deck/Gazebo 18 2008 10 2025 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.500 LS Wood framed gazebo with asphalt shingles, stone column bases, and unit
pavers is in good condition. Allow for long term refurbishment.
$ -
AD0000 Drinking Fountain 20 2008 12 2027 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.500 LS Stone framed drinking fountain is in good condition. $ -
G2050 Landscaping
AD0000 Irrigation 20 1999 3 2018 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Irrigation system (Rainbird ESP-12-LX Plus control) with Watts backflow
preventer is in good condition. Operation not verified. Allow for complete
system check with mapping and miscellaneous repairs in the short term.
$ -
AD0000 Irrigation 20 2006 10 2025 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Irrigation system (Hunter SRC Plus control) with Wilkins backflow
preventer is in good condition at pool tunnel. Operation not verified. Allow
for complete system check with mapping and miscellaneous repairs in the
short term.
$ -
AD0000 Lawns and Grasses 20 1975 -21 1994 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.002 sf Sodded areas of west sports field are in good condition with localized
wear. No allowances carried.
AD0000 Lawns and Grasses 20 1975 -21 1994 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.002 sf Sodded areas of east sports field are in good condition with localized
wear. No allowances carried.
Page 35 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Trees, Plants and
Ground Cover
40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS Consists of both mature coniferous trees and newer deciduous and
planting materials. The soft landscaping is in good condition overall. No
allowances carried over the study term.
AD0000 Trees, Plants and
Ground Cover
40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS Hiking trails located throughout the grounds are in good condition. No
future allowances carried.
AD0000 Trees, Plants and
Ground Cover
40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS The north soccer playfield is sodded and in good condition. No future
allowances carried.
AD0000 Trees, Plants and
Ground Cover
50 1970 4 2019 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Consists of both mature coniferous trees and newer deciduous and
planting materials. The soft landscaping is in good condition overall. No
significant allowances carried.
$ -
AD0000 Trees, Plants and
Ground Cover
50 1970 4 2019 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Consists of both mature coniferous trees and newer deciduous and
planting materials. The soft landscaping is in good condition overall. No
significant allowances carried.
$ -
AD0000 Trees, Plants and
Ground Cover
50 1926 -40 1975 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Consists of both mature coniferous and deciduous trees along the ravine.
No allowances carried.
AD0000 Other Learning Playspace 25 2013 22 2037 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 350.000 LS Learning playspace facility added to the Junior School.
G30 Civil and Mechanical
Utilities
$ -
G3010 Water Supply
AD0000 Site Domestic Water
Distribution
40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 12.000 LS A separate water service, from Rosewell Avenue 16" diameter water main,
enters the northeast corner of the building. System is in good condition
based on operation. Allow for longer term repairs.
AD0000 Fire Service 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 8.000 LS A separate fire line, from Rosewell Avenue 16" diameter water main,
enters the northeast corner of the building. System is in good condition
based on operation. Allow for longer term repairs.
G3020 Sanitary Sewer
AD0000 Sewage Collection 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 22.000 LS Sanitary from the Upper School Addition (1999) exits the west side of the
building and is connected to the Avenue Road main sewer line. No
reported issues with the sanitary system.
AD0000 Sewage Collection 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Sanitary from the Junior School (1999) exits the north side of the building
and is connected to the Rosewell Avenue main sewer line. No reported
issues with the sanitary system.
G3030 Storm Sewer
AD0000 Storm Water Collection 40 1999 23 2038 Good Functiona
lity
3-Not Yet
Critical
$ 75 $ - $ 75.000 LS 1 Parking lot is drained to convention catchbasins.
AD0000 Storm Water Collection 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 100.000 LS Storm distribution piping to 10 catch basins, complete with manholes,
located at north parking areas. Collection is discharged to the north
embankment headwall. Stormceptor (STC 1000) is installed to remove
free oil and suspended solids. The foundation weeping tile are shown to
be connected to the storm system. System is in good operating order with
no issues reported. Allow for longer term repairs only.
AD0000 Storm Water Collection Headwall 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.000 LS Concrete headwall and steel grate at south embankment headwall is in
good condition.
AD0000 Storm Water Collection Headwall 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.000 LS Concrete headwall and steel grate at north embankment headwall is in
good condition.
AD0000 Manhole and Catch
Basins
40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 LS Manhole and catch basin installations are performing as intended
throughout the site. No allowances made through the study period.
Cleaning of basins is considered an operational item.
AD0000 Manhole and Catch
Basins
40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 LS Manhole and catch basin installations are performing as intended
throughout the site. No allowances made through the study period.
Cleaning of basins is considered an operational item.
G3040 Heating Distribution
G3050 Cooling Distribution
G3060 Fuel Distribution
AD0000 Gas Natural Gas 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 8.000 LS Incoming gas main from Rosewell Avenue is connected to the Roots
digital main meter and Fisher regulator at the northeast corner of the
building. Exterior service is considered the responsibility of the local utility.
No allowances carried.
Page 36 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Gas Natural Gas 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 8.000 LS There is a newer gas service from Avenue Road that is connected to the
east elevation of the Service Wing complete with Roots 12000 CFH meter
and Fisher regulator. The original gas service at this location is continued
to the 900 CFH Pool meter. No allowances carried.
AD0000 Gas Natural Gas 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 8.000 LS 900 CFH Pool Mini-Max meter and Fisher regulator. No allowances
carried.
AD0000 Gas Natural Gas 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 8.000 LS Mercury meter and Fisher regulator at Kitchen area is in good condition.
No allowances carried.
G3090 Other Site Mechanical
UtilitiesAD0000 TV Inspection of Sewer
Pipelines
30 1979 -7 2008 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS Allow for the full assessment of the sanitary and storm systems with CCTV
and intrusive means in the short term. Include for mapping piping
locations and directions.
G40 Electrical Utilities $ -
G4010 Electrical Distribution
AD0000 Power Distribution Lines 50 1990 24 2039 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 50.000 LS Power distribution cabling below grade is functioning as intended based
on usage.
AD0000 Power Distribution Lines 50 1999 33 2048 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 LS Power distribution cabling below grade is functioning as intended based
on usage. No allowances carried through the study period.
G4020 Site Lighting
AD0000 Building Illumination Metal Halide 20 1991 7 2022 Fair Functiona
lity
3-Not Yet
Critical
$ 6 $ 6 $ 1.500 # 4 Wall mounted downcast light fixtures are installed on the north elevation. $ 6
AD0000 Building Illumination Metal Halide 20 1991 -5 2010 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.300 # Various wallpacks are installed throughout the exterior. Typically metal
halide, 150W type.
AD0000 Building Illumination Metal Halide 20 2006 10 2025 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.000 # Metal halide wallpack fixtures are in good condition. $ -
AD0000 Building Illumination Metal Halide 20 2006 10 2025 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.002 LS Metal halide recessed wall lighting at exterior stair locations are in good
condition.
$ -
AD0000 Other Site Lighting parking lot standards 25 1994 3 2018 Fair Functiona
lity
4-
Recomm
ended
$ 40 $ 40 $ 5.000 # 8 Parking lot is illuminate by 20' high steel light standards with single and
double fixtures.
$ 40
AD0000 Other Site Lighting parking lot standard and
400W MH luminaire
25 1999 8 2023 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.005 # Steel light standards by Norco with single light fixtures are installed
throughout the parking lots and site. Allow for long term replacement.
Cleaning and refurbishment is an Operating item.
$ -
AD0000 Other Site Lighting 25 1999 8 2023 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.013 LS Allow for a lighting study and retrofit to LED type in short term. $ -
AD0000 Other Site Lighting 25 1999 8 2023 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.022 LS Allow for a lighting study and retrofit to LED type in short term. $ -
AD0000 Other Site Lighting 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.000 # Exterior soffit lighting is in good condition. $ -
AD0000 Other Site Lighting 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.000 # Exterior wall mounted lighting is in good condition. $ -
G4030 Site Communication
and Security
G4090 Other Site Electrical
UtilitiesAD0000 Cabling 12 1991 -13 2002 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.001 LS Allow to reattach cable box cover and provide proper cabling distribution
feeds at 1961 flat roof to 1926 building.
G90 Other Site
Construction
G9010 Service Tunnels
G9090 Other Site Systems
Total $ 4 $ 51 $ 31 $ 53 $ 473 $ - $ 8,780 $ - $ 6 $ 409 $ - $ 50 $ - $ - $ 67,713 $ 14 $ - $ - $ - $ 776
Page 37 of 37
Building Name Asset ID Address Inspected By
Date of
Inspectio
n
Construction
Date
Major
Renovation
Dates
Lot Area
(acre)
Footprint
Area (sf)
Gross
Floor
Area (sf)
Roof
Area (sf)
Storeys
(#)
Basement
Levels
Overall
Conditio
n
Administrative Support Centre AD0000 CCI Group Inc 11-Aug-15 1974 1994 11500 34122 14560 2 YES Fair
Facility Name Administrative Support Centre Gross Floor Area (sf) 202000 Inspected by CCI Group Inc
Construction Year 1974 Footprint Area (sf) 11500 Date of Visit 11-Aug-15
Major Renovation Year 1994 Roof Area (sf) 14560 Overall Condition Fair
Storeys (#) 2
2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 Component Total
Substructure $ - $ - $ - $ 5 $ - $ - $ - $ - $ - $ - 5$
Shell $ - $ 6 $ 31 $ - $ 28 $ - $ - $ - $ - $ 11 75$
Interior $ - $ - $ - $ 10 $ 106 $ - $ - $ - $ - $ 27 143$
Services $ - $ 40 $ - $ 20 $ 300 $ - $ 18 $ - $ - $ 335 712$
Equipment & Furnishings $ - $ - $ - $ 18 $ - $ - $ - $ - $ - $ 10 28$
Special Construction &
Demolition $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - -$
Sitework $ 4 $ 5 $ - $ - $ 40 $ - $ 8,762 $ - $ 6 $ 26 8,843$
Total per Year 4$ 51$ 31$ 53$ 473$ -$ 8,780$ -$ 6$ 409$ 9,807$
ALL COSTS ,000s. ALL COSTS IN 2015 DOLLARS
Facility Overview
Site Summary: Asphalt paved parking lot and entrance drives are located on the north side of the site. The parking lot is drained to stormwater catch basins. A concrete unit
retaining wall separates the upper and lower parking areas. Pedestrian paving consists of unit pavers. The site is illuminated by light standards and wall mounted fixtures.
Building Description: The Toronto Zoo Administration building was constructed in 1974 and extensively renovated in 1993-1994. The building is attached to the Research and
Education Centre to the south and the Facilities Support building to the west. The Administration building consists of Change Room facilities for staff, offices, cafeteria, and
boardroom.
Building Envelope Summary: The exterior walls are clad with painted wood siding installed during the 1993-1994 renovation. Double glazed, aluminum framed windows, entry
doors, and skylights are installed. The sloped roofs are finished with metal panels. The flat roof section is finished with an inverted membrane.
Interior Finishes Summary: Interior finishes consist of concrete floor coating, terrazzo, rubber flooring, carpet, gypsum board, and lay-in ceiling tiles. Laminate cabinets and
countertops are installed. Interior finishes were typically installed in 1993-1994. Finishes are generally functional but dated.
Mechanical Summary: The building is heated hyrdonically. Boilers are located in the Facilities Support Building. Air handling units provided fresh are to the fancoil units located
throughout the building. The fancoil units provide heating and cooling with individual thermostats. Rooftop exhaust fans provide ventilation for the Washrooms and Change Rooms.
Hot water for domestic use is provided by units in the Facilities Support Building. Conventional flush valve water closets and urinals are installed.
Electrical Summary: The main electrical service is fed from the main Electrical Room in the Facilities Support Building to the Penthouse distribution panels. The 600-Volt service is
stepped down using a 150kVA transformer. T8 fluorescent and compact fluorescent light fixtures are installed throughout. Emergency power is provided by generators located on
the west side of the Vehicle Maintenance Garage.
Life Safety Summary: The building is sprinklered. A Simplex fire alarm control panel is installed. The system includes heat and smoke detectors, pull stations, and alarm bells.
Structural Summary: The basement is framed with poured concrete, including foundation walls, slab-on-grade, and concrete columns to support the first floor concrete slab. The
second floor and roof are steel framed.
$5.00 $75.20 $143 $712
$28 $-
$8,843
$-
$1,000
$2,000
$3,000
$4,000
$5,000
$6,000
$7,000
$8,000
$9,000
$10,000
Major Component
10 Year Cost Summary by Component
Substructure
Shell
Interior
Services
Equipment & Furnishings
Special Construction & Demolition
Sitework$5.00 $75.20 $143
$712
$28 $-
$8,843
$-
$1,000
$2,000
$3,000
$4,000
$5,000
$6,000
$7,000
$8,000
$9,000
$10,000
Major Component
10 Year Cost Summary by Component
Substructure
Shell
Interior
Services
Equipment & Furnishings
Special Construction & Demolition
Sitework
Name: Administrative Support Centre GFA (sf): 34122 Prepared by: CCI Group Inc
Constructed: 1974 Roof (sf): 14560 Date: 2015-08-11
Current Year: 2016
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
A SUBSTRUCTURES $ - $ - $ - $ 5 $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ -
A10 Foundations
A1010 Standard Foundations
AD0000 Wall Foundations Continuous Footings 100 1974 58 2073 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.075 lf Poured concrete strip footings, based on design drawings of newer
sections. No notable issues. No allowances made through the study
period.
AD0000 Wall Foundations Foundation Walls 100 1974 58 2073 Fair Building
Integrity
3-Not Yet
Critical
$ 5 $ 5 $ 5.000 LS 1 Foundation walls are poured concrete on concrete strip footings.
Foundations walls are in good condition where visible. Localized water
ingress was noted in the Telephone Room at the wall penetration. Allow
for short term repairs.
$ 5
A1020 Special Foundations
A1030 Slab-On-Grade
AD0000 Standard SOG Poured Concrete with
or without
reinforcement.
100 1974 58 2073 Good Building
Integrity
4-
Recomm
ended
$ 289 $ - $ 0.025 sf 11560 Concrete slab-on-grade is in good condition where exposed. Minor hairline
cracking was noted on floor coatings.
AD0000 Subdrainage Storm drainage tile. 45 1974 3 2018 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.030 lf Weeping tile systems are installed around the foundations. No adverse
conditions noted. It is assumed one repair has occurred and an allowance
is carried for repairs as needed, to coincide with foundation repairs.
$ -
A20 Basements $ -
A2010 Basement Excavation
A2020 Basement Walls
AD0000 Vertical Waterproofing Fluid Applied
Dampproofing
5 1974 -37 1978 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 8.000 LS Allow for future foundation repairs. Water entry to lower levels has
occurred in the past.
AD0000 Vertical Waterproofing Fluid Applied
Dampproofing
50 1974 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 170.000 LS Rubberized waterproofing at Athletic Centre foundation is in good
condition. Upper terminations were not well finished.
$ -
B SHELL $ - $ 6 $ 31 $ - $ 28 $ - $ - $ - $ - $ 11 $ - $ 46 $ - $ - $ 143 $ - $ - $ - $ - $ 575
B10 Superstructure $ -
B1010 Floors
AD0000 Floor Structural Frame Precast Concrete Core 100 1974 58 2073 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.075 sf Precast concrete core slabs supported on steel framing members are
used at the 2nd Floor level. HSS support columns are also used. No
issues noted and no allowances carried.
AD0000 Interior Structural Walls Concrete Block
Construction
100 1974 58 2073 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.018 sf Concrete block demising walls throughout interior areas are in good
condition. No adverse conditions noted. No allowances are made through
the study period.
AD0000 Floor Decks, Slabs and
Topping
Flat Slab, Reinforced
Concrete
100 1974 58 2073 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.029 sf Reinforced concrete floor framing including slab, support columns and
drop panels used for 2nd and 3rd Floor framing.
AD0000 Floor Decks, Slabs and
Topping
Wood Framing 100 1974 58 2073 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.029 sf Wood joists on steel beams and clay tile/masonry wall supports with
plaster ceiling and wall finishes. No allowances are carried.
AD0000 Floor Decks, Slabs and
Topping
Concrete Framing 100 1974 58 2073 Good Building
Integrity
1-
Currently
Critical
$ 335 $ - $ 0.029 sf 11560 First floor is framed with poured concrete, including concrete columns and
floor slab with dropped panels. The elevator core is poured concrete. No
issues were noted.
AD0000 Floor Decks, Slabs and
Topping
Composite Metal Deck 100 1974 58 2073 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.035 sf The floors are composite metal deck supported by steel joists and
columns. No issues reported. No allowances are carried throughout he
study period.
AD0000 Floor Structural Frame 100 1974 58 2073 Good Building
Integrity
1-
Currently
Critical
$ 667 $ - $ 0.029 lf 23000 Second floor consists of metal deck with concrete topping supported by
open web steel joists (OWSJ), steel wide-flange beams, and steel
columns.
ALL COSTS IN 000' (2015) DOLLARS
Page 1 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Interior Structural Walls Concrete Block
Construction
100 1974 58 2073 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.018 sf Concrete block demising walls throughout interior areas are in good
condition. No adverse conditions noted. Replacement costs are not
anticipated during this study period.
AD0000 Floor Decks, Slabs and
Topping
Composite Metal Deck 100 1974 58 2073 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 35.000 sf The basement, first (mezzanine), and second floor levels are framed with
conventional steel members. A combination of composite metal deck,
reinforced concrete, and concrete joists exist throughout the building.
Replacement costs are anticipated during this study period.
AD0000 Floor Structural Frame Floor Girders and
Beams
100 1974 58 2073 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 240.000 lf Steel I beams support open web steel joists and composite metal deck.
No adverse conditions noted. Replacement costs are not anticipated
during this study period.
AD0000 Interior Structural Walls Concrete Block
Construction
100 1974 58 2073 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 18.000 sf Concrete block demising walls throughout interior areas are in good
condition. No adverse conditions noted with the exception of the block
back-up walls of the Junior School Gymnasium where extensive vertical
cracking was noted. Allow to provide crack monitors in the short term to
determine if cracks are actively moving. Allow to rout and seal the joints
with flexible sealants. Replacement costs are not anticipated during this
AD0000 Interior Structural Walls Concrete Construction 100 1974 58 2073 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 18.000 sf Reinforced concrete construction of pool basin covered under other Item.
Replacement costs are not anticipated in this study.
AD0000 Floor Fireproofing Sprayed 40 1974 10 2025 Fair Building
Integrity
1-
Currently
Critical
$ 46 $ 46 $ 0.004 sf 11560 Sprayed fireproofing applied to underside of steel beams and decking is in
good condition.
$ 46
AD0000 Wall Firestopping 30 1974 -12 2003 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.000 LS Firestopping at wall pipe penetrations is in good condition. Firestopping at
top of block walls at Level 300 areas could be better; allow for repairs.
B1020 Roof Construction
AD0000 Roof Structural Frame Girders and Beams 100 1974 58 2073 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 13.000 sf Steel beams, columns, open web steel joists and long span tapered joists
and metal roof deck are installed for the main roof framing. All systems,
where exposed are in good condition. No allowances carried.
AD0000 Roof Structural Frame Roof Trusses 100 1974 58 2073 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.000 sf Assembly Hall has solid wood framed trusses with tongue-and-groove roof
decking are in good condition with no damage observed. Replacement
cost is not carried.
AD0000 Roof Structural Frame Steel 100 1974 58 2073 Good Building
Integrity
1-
Currently
Critical
$ 231 $ - $ 0.020 sf 11560 Flat and sloped roof sections are steel framed. Metal decking is installed.
AD0000 Roof Structural Frame Steel 100 1974 58 2073 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 sf Tongue=and=groove wood roof deck on steel beams and columns at west
foyer.
AD0000 Floor Structural Frame Floor Girders and
Beams
100 1974 58 2073 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 240.000 lf Concrete roof framing at mezzanine level is in good condition.
AD0000 Roof Structural Frame Roof Trusses 100 1974 58 2073 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.000 sf 72' span and 4' deep steel trusses in the Pool are in good condition. No
allowances carried over the study period.
AD0000 Roof Structural Frame Roof Trusses 100 1974 58 2073 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.000 sf Long span steel trusses in the Gym are in good condition. No allowances
carried over the study period.
B20 Exterior Closure $ -
B2010 Exterior Walls
AD0000 Wall Construction Masonry Brick Wall with
Block Back-up
50 1974 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.025 sf Jumbo sized clay brick veneer walls are in good condition. The assembly
is installed as a veneer system complete with weepholes and 1" air space,
insulation and block back-up. Algae/moss growth was evident in localized
areas. Allow for longer term repairs based on 10% of total area.
$ -
Page 2 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Wall Construction Wood Clad Exterior
Walls
50 1994 28 2043 Good Building
Integrity
4-
Recomm
ended
$ 195 $ - $ 0.030 sf 6500 Exterior walls are clad with diagonally and horizontally installed ship lap
wood siding. The cladding has been painted recently.
AD0000 Wall Construction Precast Concrete 40 1974 -2 2013 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.025 sf Precast concrete wall panels are installed at the clock tower and accent
areas on the south elevation. The panels are in good condition with no
damage. Allow for longer term repairs and cleaning only.
AD0000 Parapets 20 1974 -22 1993 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.023 lf Caulking at parapet cap stones is in poor condition. Allow for
repairs/replacement in short term.
AD0000 Other Caulking 18 1974 -24 1991 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.009 lf Sealants at windows, doors and wall control joints are in good condition
throughout. Allow for replacement in the longer term. Localized failure at
window sills and chiller pipe penetrations was noted; allow for repairs in
short term.
AD0000 Other Exterior Walls Thermography 6 1974 -36 1979 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Allowance for exterior wall thermography in short term.
AD0000 Outside Wall Exterior
Skin
Stone Masonry with
Block Back-up
75 1974 33 2048 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.035 sf Solid stone masonry with a block backup wall throughout the original
building is in fair condition. Larger sections of the cladding is covered by
vegetation. Significant staining is visible throughout, and indicating
leaching of iron impurities through stones. Major repair (20% of total) is
allocated for the longer term with intermittent repairs in short term.
AD0000 Outside Wall Exterior
Skin
Bridge 50 1974 8 2023 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 LS Bridge repairs at main entrance are required. Concrete pad and trench
drain are in good condition. No structural issues as previously reported by
others.
$ -
AD0000 Outside Wall Exterior
Skin
Bridge 50 1974 8 2023 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 LS Bridge repairs at main entrance are required. Concrete pad and trench
drain are in good condition. No structural issues as previously reported by
others.
$ -
AD0000 Outside Wall Exterior
Skin
Exterior Insulation Finish
System (EIFS) Wall
System
20 1974 -22 1993 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.012 sf A newer EIFS (stucco)cladding has been installed on the east elevation
which have a life expectancy of 40+ years if maintained. The durability of
this system depends on the integrity of the joints. Annual inspection and
localized repair is recommended. The finish will require refurbishment
every 20 years which has been included in this study period.
AD0000 Outside Wall Exterior
Skin
Stone Masonry with
Block Back-up
75 1974 33 2048 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.035 sf Masonry with a block backup wall is located on the west elevation and is
in fair condition. Annual inspection and localized repairs of stone flaking,
delamination and cracks to prevent damage caused by moisture
penetration. Repair costs are included every 5 years, as needed.
AD0000 Wall Construction Brick Masonry with
Block Back-up
75 1974 33 2048 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.025 sf The 1961 building forming part of the Athletic Building has masonry brick
tied to interior concrete block forming a solid masonry wall and is in fair
condition. The 2006 addition encloses the north and east walls, the south
and west walls remain exposed. Re-pointing of the mortar joints and
replacement of any damaged bricks is carried every 10 years, as needed.
Routine inspection and localized repairs are recommended. 30%
allocation made.
AD0000 Outside Wall Exterior
Skin
Precast Concrete
Panels (stucco finish)
with Insulation and
Concrete Block Back-
up
20 1974 -22 1993 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.012 sf 5" precast concrete panels on 2" insulation and 4" concrete block backup
wall are in good condition. The panels have been recoated with an acrylic
stucco to match the EIFS exterior of the 1999 addition. Split sealant
between panels was observed (separate line item). An allowance is
carried for refinishing of the stucco coating every 20 years, as needed.
Includes copper downspouts to below grade.
AD0000 Outside Wall Exterior
Skin
Stone Veneer with
Block Back-up
75 1974 33 2048 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.025 sf Sections of stone veneer is located on all elevations and are in good
condition. There is an insulating cavity between the stone and interior
block wall. Weep holes are provided over windows, doors, and at the
bottom of walls. An allowance is carried for re-pointing the mortar joints at
25 years, every 2 years at 20% of area.
AD0000 Outside Wall Exterior
Skin
Exterior Insulation Finish
System (EIFS) Wall
System
20 1974 -22 1993 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.012 sf EIFS (stucco) cladding is located at the north elevation. The durability of
this system depends on the integrity of the joints. The finish will require
refurbishment every 20 years. Allow for recoating and repairs in the longer
term. Annual inspection and localized repairs is recommended.
Replacement costs are not anticipated within this study period.
AD0000 Outside Wall Exterior
Skin
Exterior Insulation Finish
System (EIFS) Wall
System
20 1974 -22 1993 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.012 sf EIFS (stucco) cladding is located at the north elevation. The durability of
this system depends on the integrity of the joints. The finish will require
refurbishment every 20 years. Allow for recoating and repairs in the longer
term. Annual inspection and localized repairs is recommended. Major
replacement costs are not anticipated within this study period.
AD0000 Outside Wall Exterior
Skin
Exterior Insulation Finish
System (EIFS) Wall
System
20 1974 -22 1993 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.012 sf EIFS (stucco) cladding is located at the east building (Pool). The durability
of this system depends on the integrity of the joints. The finish will require
refurbishment every 20 years. Allow for recoating and repairs in the longer
term. Replacement costs are not anticipated within this study period.
Page 3 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Outside Wall Exterior
Skin
Prefinished Insulated
Aluminum Panels
45 1974 3 2018 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.045 sf Prefinished insulated aluminum panel accents throughout the building.
Refurbishment of the aluminum panels will be required every 20 years
which falls below the threshold of this study. Replacement costs are not
anticipated within this study period.
$ -
AD0000 Outside Wall Exterior
Skin
Copper Cladding 75 1974 33 2048 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.037 sf 32 oz. copper sheeting over plywood sheathing is located at the west
entrance and Archive Addition. Surfaces are in good condition. Routine
inspection and localized repairs is recommended as needed.
Replacement costs are not anticipated during this study period.
AD0000 Outside Wall Exterior
Skin
Copper Cladding 75 1974 33 2048 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.000 LS Copper cladding at parapet is in good condition with minor damage.
AD0000 Outside Wall Exterior
Skin
Stone Veneer with
Block Back-up
75 1974 33 2048 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.025 sf Sections of stone veneer is located on all elevations and in good
condition. There is an insulating cavity between the stone and interior
block wall. Weep holes are provided over windows, doors, and at the
bottom of walls. Annual inspection and localized repairs is recommended,
as needed. Re-pointing should commence at 30 years. No allowances are
carried within this study period. Allow for re-pointing 20% in 2036.
AD0000 Other Exterior Walls Caulking 20 1994 1 2016 Poor Building
Integrity
2-
Potenially
Critical
$ 11 $ 11 $ 0.012 lf 900 Sealants at windows, skylight, and doors are failing. Cracking was noted
throughout. Allow for short term replacement to maintain a watertight
envelope.
$ 11
AD0000 Other Exterior Walls Caulking 20 1974 -22 1993 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.012 lf Sealants at windows, doors, flashing, control joints of EIFS and at the
junction of the different materials are in fair condition. The EIFS joints are
not well tooled and failure has occurred. Allow for replacement in the short
term,
AD0000 Other Exterior Walls Caulking 20 1974 -22 1993 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.012 lf Sealants at windows, doors, base flashing and curtainwall are in fair
condition with localized failure throughout. Allow for repairs in the long
term as full replacement is imminent.
AD0000 Other Exterior Walls Caulking 20 1974 -22 1993 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.012 lf Sealants at windows, doors, base flashing, curtainwall, control joints, and
at the junction of different materials are in fair condition with localized
failure throughout. Allow for repairs in the short term as full replacement is
imminent.
B2020 Exterior Windows
AD0000 Curtain Wall 30 1974 -12 2003 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.083 sf Aluminum framed curtainwall system on the north elevation is in fair
condition.
AD0000 Curtain Wall 30 1974 -12 2003 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 65.000 sf Thermally-broken aluminum framed double-glazed sealed window units
are in good condition. Allow for replacement in longer term. Includes
southeast foyer entrance.
AD0000 Historical Windows 30 1974 -12 2003 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 290.000 LS Lead framed windows with the Brenda Robson Hall and Ellen Knox
Library were restored between 2012 and 2014. Six of the windows do not
match the original windows. Routine refurbishment is needed, and major
restoration every 30 years. Allow also for refurbishment of the northwest
stair to the Brenda Robson Hall and the Residence Head Apartment
windows in the future.
AD0000 Skylight 40 1994 18 2033 Good Building
Integrity
4-
Recomm
ended
$ 15 $ 15 $ 15.000 LS 1 Aluminum framed, double glazed skylights are installed above the central
Corridor. The skylights are in good condition but sealants are failing.
$ 15
AD0000 Standard Windows Aluminum Type 35 1994 13 2028 Good Building
Integrity
4-
Recomm
ended
$ 143 $ 384 $ 0.065 sf 2200 Aluminum framed, double glazed windows are installed throughout. $ 143
AD0000 Standard Windows 25 1974 -17 1998 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.065 sf Thermally-broken aluminum framed double-glazed sealed insulating
window units were replaced between 2008 and 2013 in the 1926/1961
wings. Includes fixed and casement styles. No issues have been
reported, the windows are in good condition. Allow for replacement in
longer term.
AD0000 Standard Windows -
Dormers
25 1974 -17 1998 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.065 sf Dormer windows: thermally-broken vinyl framed double-glazed sealed
insulating window units are in good condition. The exteriors were also
refinished with aluminum siding and metal roofs. Allow for replacement in
longer term.
AD0000 Weatherstripping 15 1974 -27 1988 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Window and door weatherstripping is in fair condition.
B2030 Exterior Doors
Page 4 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Exterior Entrance Doors Aluminum, Double 30 1974 -12 2003 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 7.000 # Aluminum, double glazed, double doors at main west (#4) entrance is in
good condition. Includes automatic operators.
AD0000 Exterior Entrance Doors Aluminum, Single 25 1994 3 2018 Fair Building
Integrity
4-
Recomm
ended
$ 20 $ 20 $ 10.000 # 2 North entrances are single, aluminum framed, double glazed doors with
sidelights.
$ 20
AD0000 Exterior Entrance Doors Aluminum, Single 40 1974 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 # Aluminum framed by Kawneer, full glazed doors at north quadrant are in
fair condition. Replace with curtainwall system.
AD0000 Exterior Entrance Doors Metal Clad, Double 25 1974 -17 1998 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.000 # Metal/wood framed doors with glazing, located at east foyer and north
central stair 2, are in good condition.
AD0000 Exterior Entrance Doors Metal, Single 30 1994 8 2023 Good Building
Integrity
4-
Recomm
ended
$ 3 $ 4 $ 3.000 # 1 Metal clad exit door on the south elevation. $ 1 $ 3
AD0000 Exterior Entrance Doors Wood Entrance, Double 30 1974 -12 2003 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 8.000 # Main entrance (#1) is fitted with double wood doors with single glazing.
The doors are in fair condition with localized wear. Allow to refurbish in
short term and replace/major refurbish in longer term.
AD0000 Exterior Service Doors Metal Clad, Double 30 1974 -12 2003 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.000 # Metal clad doors at west exit (#2) at Bridge are in good condition.
AD0000 Exterior Service Doors Metal, Single 30 1974 -12 2003 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Metal clad single door at service garage (#11) is in good condition.
AD0000 Utility Doors Overhead Roll-up Type 20 1974 -22 1993 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.000 # Older overhead door at the Service Garage. Allow to update in the short
term including overhead door motor and control.
B30 Roofing $ -
B3010 Roof Coverings
AD0000 Flashing and Sheet
metal
25 1974 -17 1996 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Prefinished metal flashing and counter flashing are in good condition.
Allow for future replacement with the roofing membrane component.
AD0000 Manufactured Roofing Accessories 30 1974 -12 2003 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.500 LS Older tubular steel flag pole at Tower roof is in fair condition.
AD0000 Manufactured Roofing Flat, BUR 20 1974 -22 1993 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.012 sf Flat 4-ply built-up asphalt felt membrane system with perimeter sheet
metal flashing. The drainage is adequate via central drains. No issues
reported. Allow for routine annual maintenance. Replacement cost carried
for the flat roofs within the next 5 years.
AD0000 Manufactured Roofing Flat, concrete 30 1974 -12 2003 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.017 sf The roof of the Grade 12 Common Locker Room is protected by a
waterproofing membrane and concrete cover. Allow to re-coat in short
term.
AD0000 Manufactured Roofing Flat, Inverted 30 1974 -12 2003 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.022 sf Inverted Roof Membrane System (IRMA) includes river washed stone
ballast and precast pavers, filter fabric, insulation, modified bitumen roof
membrane on sheathing board over steel deck. Drainage is adequate via
central drains. Routine annual maintenance is recommended. Replace in
long term, costs included in study.
AD0000 Manufactured Roofing Sloped, Metal 40 1994 18 2033 Good Building
Integrity
4-
Recomm
ended
$ 20 $ 560 $ 580 $ 0.040 sf 14000 Sloped roofs are finished with standing seam metal roofing. Snow guards
are installed. Minor wear and surface corrosion was noted. Allow for short
term refurbishment.
$ 20 $ 560
AD0000 Manufactured Roofing Sloped, PVC 35 1974 -7 2008 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.015 sf Single layer, PVC membrane over the Theatre Roof is in good condition.
The drawings indicate that the roof is installed on 3" rigid insulation,
vapour barrier on cement board.
Page 5 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Manufactured Roofing Sloped, shingle 18 1974 -24 1991 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.006 sf Asphalt shingles are located on the sloped roofs of the North Wing
(Resource Centre). Significant curling and deterioration was observed.
Drainage is via aluminum eavestrough and leaders to the ground.
Replacement cost is carried for the asphalt shingles in year 1.
AD0000 Membrane Roofing Flat Conventional 20 1974 -22 1993 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.019 sf The canopy roof is protected by a conventionally applied modified bitumen
membrane. The membrane is wearing well.
AD0000 Membrane Roofing Flat Inverted 30 1994 8 2023 Good Building
Integrity
1-
Currently
Critical
$ 5 $ 8 $ 13 $ 0.015 sf 560 Flat roof is finished with an inverted membrane with rigid insulation, scrim
sheet, and river rock ballast. Past water ingress was noted in the second
floor Storage Room below the inverted roof. Allow for further investigation
and repairs.
$ 5 $ 8
AD0000 Other Trellis 25 1974 -17 1998 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 7.500 LS Wood trellis on steel beam supports is in good condition. Allow for
complete refurbishment in longer term.
AD0000 Roof Specialties and
Accessories
Eavestroughs and
Downspouts
25 1994 3 2018 Good Building
Integrity
4-
Recomm
ended
$ 8 $ 8 $ 7.500 LS 1 Eavestroughs and downspouts are installed on the north and south
elevations. Downspouts continue below grade to the weeping tile system.
$ 8
AD0000 Roof Specialties and
Accessories
Soffits 35 1974 -7 2008 Fair Appearan
ce
4-
Recomm
ended
$ 1 $ - $ 1.000 LS 1 Transite soffit panels are installed at the north entrances. Allow to
refurbish.
C INTERIOR $ - $ - $ - $ 10 $ 106 $ - $ - $ - $ - $ 27 $ - $ 4 $ - $ - $ - $ - $ - $ - $ - $ -
C10 Interior Construction $ -
C1010 Partitions
AD0000 Gymnasium Divider 25 1974 -17 1998 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 12.000 LS Gym divider is vinyl clad gypsum board. The partition is in good condition.
AD0000 Interior Fixed Partitions Concrete Block Type 45 1974 29 2044 Good Building
Integrity
4-
Recomm
ended
$ 16 $ - $ 0.020 sf 800 Partitions in the basement are concrete block. Glazed concrete block is
installed at wet areas in the Change Rooms. Concrete block partitions are
in good condition overall. Localized cracking was noted at the entrance to
the Women's Change Room.
AD0000 Interior Fixed Partitions Gypsum Board 45 1974 3 2018 Fair Appearan
ce
4-
Recomm
ended
$ 5 $ 5 $ 5.000 LS 1 First and second floor partitions are steel framed and finished with gypsum
wall board. Minor wear and damage was noted in high traffic areas. An
allowance has been made for repairs and installation of wall coverings and
corner guards.
$ 5
AD0000 Interior Windows 40 1974 24 2039 Good Building
Integrity
1-
Currently
Critical
$ 50 $ - $ 0.100 sf 500 Steel framed glazing is installed at the basement stair, Cafeteria, and
Reception. Glazing in the basement is Georgian Wire Glass (GWG).
AD0000 Interior Windows 40 1974 -2 2013 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 LS Original wood framed windows facing interior light well are in fair condition.
Allow to refinish in longer term.
AD0000 Interior Windows 40 1974 -2 2013 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.100 sf Interior glazing at mezzanine is frameless and in good condition.
Replacement not anticipated.
AD0000 Operable and Folding
Panel
Accordion Type 25 1974 -17 1998 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.500 # Vinyl clad gypsum hardboard accordion partitions are installed within the
Classrooms. Includes control devices and tracks. Allow for long term
replacement.
AD0000 Toilet Partitions 20 1994 8 2023 Fair Appearan
ce
4-
Recomm
ended
$ 24 $ 24 $ 1.000 # 24 Washrooms and Change Rooms are equipped with laminate toilet and
shower stall partitions. The partitions are dated but functional.
$ 24
C1020 Interior Doors
AD0000 Fire Doors Hollow Metal Type 40 1974 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 1.400 # The 4th Floor Bedrooms are equipped with hollow wood type doors and
metal knock-up frames. The components are UL rated with standard knob
type pass sets and no self-closers.
AD0000 Interior Entrance Doors Aluminum Type 30 1974 -12 2003 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.400 # Aluminum framed, full glazed panel door systems are in good condition.
Includes single and double swing type.
Page 6 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Interior Swing Doors Metal Clad 25 1974 -17 1998 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 1.700 # Single leaf metal doors to Tower Level 500 stairwell are in good condition.
Replacement anticipated in longer term.
AD0000 Interior Swing Doors Metal Doors 25 1974 -17 1998 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.900 # Older metal doors in basement and sub-basement areas are in fair
condition. Newer metal clad doors are also installed at service doors.
AD0000 Interior Swing Doors Solid Wood 25 1974 -17 1998 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.300 # Single leaf wood doors at Tower Level 500 are in good condition.
Replacement not anticipated; refurbish only.
AD0000 Interior Swing Doors Wood Laminate Type 30 1974 -12 2003 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.400 # Wood laminate doors, in metal frames, are in good condition at the Pool
and Gym area.
AD0000 Interior Swing Doors 25 1994 3 2018 Fair Appearan
ce
4-
Recomm
ended
$ 100 $ 100 $ 1.000 # 100 Fire rated metal doors in metal frames are installed at stairwells and
service rooms. Laminate doors with stainless steel kickplates are installed
at common areas. Lever type hardware is installed.
$ 100
AD0000 Large Interior Doors Rolling Metal Door 50 1974 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 # Rolling metal door at Boiler Room is in good condition. Could possibly
contain asbestos within core. Allow for longer term replacement.
$ -
AD0000 Other Interior Doors Hardware 15 1974 -27 1988 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 115.000 LS The facility has no master keying system. A key audit and installation
project is slated for 2016.
AD0000 Other Interior Doors Hardware 25 1974 -17 1998 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 LS Sargent lever type door latches are in good condition.
C1030 Fittings
AD0000 Change room Cubbies
and Bench
Wood 25 1994 10 2025 Fair Appearan
ce
4-
Recomm
ended
$ 4 $ 4 $ 4.000 LS 1 Steel framed benches with wood slat seating are installed in the Change
Rooms. Minor wear was noted.
$ 4
AD0000 Fabricated
Compartments and
Cubicles
Washroom / Shower
Stall
20 1974 -22 1993 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 1.000 # Metal washroom and shower stalls are in good condition. Costs for
replacement included for under Interior Finishes Section.
AD0000 Fabricated
Compartments and
Cubicles
Washroom Stall 20 1974 -22 1993 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 1.200 # Metal washroom stalls are in good condition. Replace stalls in the longer
term.
AD0000 Lockers Steel 25 1994 3 2018 Fair Functiona
lity
4-
Recomm
ended
$ 1 $ 1 $ 1.000 LS 1 Full and half height steel lockers are installed in the Change Rooms.
Locker doors are perforated for venting.
$ 1
AD0000 Lockers Steel Type 25 1974 -17 1998 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.500 LS Steel, baked enamel finish, full height, lockers are in fair condition.
AD0000 Storage Shelves Wood 25 1974 -17 1998 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Wood framed laminate lockers, with open shelf top and bottom, are in
good condition.
C20 Stairs $ -
C2010 Stair Construction
AD0000 Access Ladder 40 1974 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 LS Steel access ladder and plywood access hatch at top of Tower stairwell
require protection.
AD0000 Concrete Stairs 100 1974 58 2073 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ - # 0 Central basement stair is concrete and finished with rubber flooring.
Textured strips are installed on nosings. Wall mounted tubular steel
handrails are installed. Finishes are included with flooring.
Page 7 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Concrete Stairs 75 1974 33 2048 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 # Level 100: Southwest exit stair #18 has no handrails and landing is short.
AD0000 Concrete Stairs 75 1974 33 2048 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 # Level 100: Northwest interior terrazzo stair has one discontinuous
handrail. Allow to adjust/add handrails.
AD0000 Concrete Stairs 75 1974 33 2048 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 # Level 100 to Level 200: Northwest interior terrazzo stair has one
continuous handrail. Allow to add 2nd handrail due to width of stairs.
AD0000 Flooring - Junior School 25 1974 -17 2015 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.011 sf Marmoleum sheet flooring at stair treads, risers and landings is in good
condition with localized deterioration (cracking) at upturn junctions. Allow
for repairs in short term and replace in longer term.
AD0000 Flooring - Junior School 20 1974 -22 2015 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.006 LS Carpet flooring at main stairs is in good condition.
AD0000 Guards 40 1974 2 2017 Fair Appearan
ce
5-Does
Not Meet
Current
Code
$ 10 $ 10 $ 0.100 lf 100 Steel framed guards with wood handrail and glazing are installed at the
second floor. Guard height is slightly below current standards at 41.5".
Guards are not considered compliant as they are climbable. Allow for short
term modifications.
$ 10
AD0000 Handrails 40 1974 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 LS Level 400: Wood handrails on either side of balcony loft require height
adjustment and relocation to ensure proper mounting clearance to wall.
AD0000 Metal Stairs Metal Pan Type 100 1974 58 2073 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ - # 0 North and south exit stairs are steel with concrete pan infill. Textured strips
are installed on nosings. Tubular steel handrails and guards are installed.
Steel components have been painted. Handrail and guard heights are
compliant where measured.
AD0000 Metal Ladders Vertical Metal Ladders 30 1994 8 2023 Fair Functiona
lity
4-
Recomm
ended
$ 3 $ 3 $ 3.000 # 1 Typical steel access ladder on the west elevation, providing access to the
flat roof, is in fair condition.
$ 3
AD0000 Metal Stairs Metal Pan Type 75 1974 33 2048 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 65.000 # Levels 200 and 100: Steel framed stairs at northeast corner exit stair 8 are
in good condition. Replacement not anticipated. Guards at 42" in height.
Finished with vinyl floor tile and gypsum board ceiling.
AD0000 Metal Stairs Metal Type 30 1974 -12 2003 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 1.500 # Sub-Basement Level: Steel stair at Carpenter Shop to Exit #19 door is in
fair condition. Allow for shorter term refurbishment only.
AD0000 Railings and Balustrades 40 1974 -2 2013 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.125 lf Steel pipe handrails are in good condition throughout the stairwells. No
replacement carried over the study period. Guard height, handrail
configuration and picket spacings are compliant. Repaint handrails and
guards in longer term.
AD0000 Wood Stairs Wood & Steel
Components
75 1974 33 2048 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 14.000 # Levels 400, 300, 200 and 100: Southeast Stairwell to exit Door #17 with
low guard, wood framed, rubber floor and finish.
AD0000 Wood Stairs 75 1974 33 2048 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 # Central stair to the second floor is wood framed and finished with carpet.
Steel guards with wood handrails are installed. Handrails are compliant,
however they do not extend beyond the stair. This was likely acceptable at
the time of construction due to the high traffic area. Replacement of carpet
is included with flooring.
AD0000 Wood Stairs 40 1974 -2 2015 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 1.500 LS Level 400: Allow to add handrail to 4th Floor Corridor at east end stair to
service roof exit.
C2020 Stair Finishes
C30 Interior Finishes $ -
C3010 Wall Finishes
Page 8 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Acoustical Treatment 22 2010 16 2031 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.012 sf 200 Level Floor or C Level: C29 Library is finished with vinyl tile floor,
carpet, painted concrete block and painted gypsum board ceiling.
Includes four offices.
$ -
AD0000 Concrete Wall Finishes 40 1974 -2 2013 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.005 sf 000 Level Floor or A Level: Hall is finished with older vinyl tile floor,
painted concrete block and lay-in acoustical tile ceiling.
AD0000 Gypsum Board Walls
Finishes
45 2010 39 2054 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.016 sf 000 Level Floor: A24 Locker Room - finished with older vinyl tile, full
height lockers, painted block walls and newer lay-in ceiling tile.
AD0000 Interior Wall Painting 8 2010 2 2017 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.003 sf 200 Level Floor: Storage Lab Rooms and C30 Slop Sink Room are in
need of updating.
$ -
AD0000 Other Wall Finishes 15 2010 9 2024 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.011 sf 500 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ -
AD0000 Plaster Wall Finishes 45 2010 39 2054 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.016 sf 000 Level Floor: A27 Bio Lab was recently refinished with new
furnishings, lay-in acoustical ceilings tiles with older vinyl floor tile. All new
furnishings.
AD0000 Stone Faced Wall
Finishes
45 2010 39 2054 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.037 sf 200 Level Floor or C Level: Hall is finished with older vinyl tile floor,
painted concrete block and lay-in acoustical tile ceiling.
AD0000 Tile Wall Finishes Ceramic Tile 35 2010 29 2044 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.022 sf 100 Level Floor: Classrooms and Study Rooms are finished with vinyl
floor tile, painted block and drywall walls and lay-in tile ceilings. Includes
B39, B38, B37, B20 Science Lab, B19, B18, B17, B16, B15. Fume hood
by Advanced HRPA Technologies (model# 7321002, serial# 4176-02) .
AD0000 Tile Wall Finishes Cut Natural Stone Tile 35 2010 29 2044 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.023 sf 100 Level Floor: Storage areas such as the B40 Slop Sink Room require
immediate updating of finishes. B40 Electrical Room requires refinishing.
AD0000 Tile Wall Finishes Glass Mosaic 35 2010 29 2044 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.025 sf Allow to update older Washroom to barrier free type.
AD0000 Tile Wall Finishes Metal Tile 35 2010 29 2044 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.016 sf 100 Level Floor: Student Washroom is finished with older ceramic floor
tile, painted plaster walls with ceramic mosaic tile and lay-in tile ceilings.
Includes 33" wide door with auto opener, 34.25" barrier free stall, ceramic
tile floor and ceramic mosaic tile walls, Duravit pedestal type sink at 33.25"
high with uninsulated piping at 9" back, wall hung American Standard with
Teck toggle, metal stall partitions
AD0000 Tile Wall Finishes Plastic Tile 35 2010 29 2044 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.012 sf 100 Level Floor: Offices and Copy Room - vinyl tile floors, newer lay-in
acoustical ceiling tiles, plaster walls. Includes B45, B49, B50, B51
(carpet), B51, B53, B54, B46, B55
AD0000 Tile Wall Finishes Quarry Tile 35 2010 29 2044 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.022 sf 100 Level Floor: Staff Washrooms (2) at Lounge are finished with older
and newer ceramic floor tile, painted plaster walls and ceilings. Fixtures
include older American Standard water closet and vanity. 2nd Washroom
at Lounge has 3 older wall hung American Standard water closets with
auto flush and two vitreous clay sinks. Allow to update.
AD0000 Veneer Plaster Finishes 35 2010 29 2044 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.012 sf 100 Level Floor or B Level: Hall is finished with older vinyl tile floor,
painted concrete block and lay-in acoustical tile ceiling.
AD0000 Wall Coverings 8 2010 2 2017 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.009 sf 200 Level Floor: Office C11 has newer carpet, painted gypsum board and
older lay-in tile ceiling.
$ -
AD0000 Wall Paneling 25 2010 19 2034 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.012 sf 0 Acoustical wall paneling is installed in the Boardroom.
AD0000 Wall Trim and
Decoration
8 2010 2 2017 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 15.000 LS 200 Level Floor: Classrooms C12, C13 are finished with vinyl floor tile,
C14 has carpet, painted block and drywall walls and lay-in tile ceilings.
$ -
C3020 Floor Finishes
AD0000 Access Flooring 20 2010 14 2029 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.016 sf 513 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ -
AD0000 Carpet 8 1994 3 2018 Fair Appearan
ce
4-
Recomm
ended
$198.000 $0.000 $ 0.009 sf 22000 Fitness Room, Offices, and second floor areas are finished with sheet type
carpeting. Carpet tiles are installed in the Security Office. Wear was noted
in high traffic areas.
$ -
Page 9 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Concrete Floor Finishes 12 2010 6 2021 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.010 sf 500 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ -
AD0000 Floor Painting 6 2010 0 2015 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.003 sf 515 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ -
AD0000 Floor Topping 25 2010 19 2034 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.010 sf 516 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Floor Treatment 20 2010 10 2025 Good Building
Integrity
1-
Currently
Critical
$90.000 $0.000 $ 0.015 sf 6000 Change Room, Washroom, and Janitor Room floors are finished with a
textured coating on the concrete slabs. Minor cracking was noted
throughout. The flooring is functional.
$ -
AD0000 Other Floor Finishes 20 2010 14 2029 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.015 sf 518 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ -
AD0000 Other Wall Finishes 15 2010 9 2024 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 19.011 sf 519 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ -
AD0000 Other Wall Finishes 15 2010 9 2024 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 20.011 sf 520 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ -
AD0000 Other Wall Finishes 15 2010 9 2024 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 21.011 sf 521 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ -
AD0000 Other Wall Finishes 15 2010 9 2024 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 22.011 sf 522 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ -
AD0000 Other Wall Finishes 15 2010 9 2024 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 23.011 sf 523 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ -
AD0000 Resilient Flooring 20 1994 5 2020 Good Building
Integrity
1-
Currently
Critical
$54.000 $0.000 $ 0.012 sf 4500 Basement and first floor Corridors and Cafeteria are finished with textured
rubber flooring. The flooring is in fair condition overall with localized wear.
The flooring is functional though dated.
$ -
AD0000 Stone Flooring 75 2010 69 2084 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.012 sf 509 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Terrazzo Floor Finishes 45 1974 3 2018 Good Building
Integrity
1-
Currently
Critical
$61.500 $0.000 $ 0.041 sf 1500 Main entrance Vestibule and Foyer are finished with terrazzo flooring.
Minor cracking was noted.
$ -
AD0000 Tile Floor Finishes Ceramic Tile 30 2010 24 2039 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.028 sf 501 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Tile Floor Finishes Cut Natural Stone Tile 30 2010 24 2039 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.026 sf 506 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Tile Floor Finishes Glass Mosaic 30 2010 24 2039 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.028 sf 503 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Tile Floor Finishes Metal Tile 15 2010 9 2024 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.018 sf 505 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ -
AD0000 Tile Floor Finishes Plastic Tile 15 2010 9 2024 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.013 sf 504 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ -
AD0000 Tile Floor Finishes Quarry Tile 30 2010 24 2039 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.025 sf 502 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Traffic Coatings 20 2010 14 2029 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.008 sf 517 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ -
AD0000 Unit Masonry Flooring 75 2010 69 2084 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.010 sf 510 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Wood Flooring 25 2010 19 2034 Good Building
Integrity
1-
Currently
Critical
$0.000 $0.000 $ 0.022 sf 508 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
C3030 Ceiling Finishes
AD0000 Acoustical Treatment 25 1994 3 2018 Fair $352.000 $352.000 $ 0.016 sf 22000 Lay-in ceiling tiles are installed throughout the Offices and Storage
Rooms. Tiles and T-bar framing are in fair condition overall. Localized
staining and damaged framing were noted. Allow for short term repairs
and then replacement.
$ 352
AD0000 Ceiling Paneling 30 1994 8 2023 Good $52.500 $352.000 $ 0.015 sf 3500 Suspended ceiling panels are installed throughout the first floor Corridors,
Cafeteria, and Board Room. Paneling is in fair condition overall but dated.
$ 352
AD0000 Ceiling Trim and
Decoration
15 2010 9 2024 Good $0.000 $352.000 $ 15.000 LS 530 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ 352
Page 10 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Concrete Ceiling
Finishes
45 2010 39 2054 Good $0.000 $0.000 $ 0.006 sf 523 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Gypsum Board Finishes 45 2010 39 2054 Good $10.800 $0.000 $ 0.018 sf 600 Ceilings in the Washrooms, Reception area, Vestibules, and Boardroom
are finished with painted gypsum board. Gypsum board is expected to last
the life of the building. Repairs are considered maintenance.
AD0000 Interior Ceiling Painting 8 2010 2 2017 Good $0.000 $352.000 $ 0.004 sf 529 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ 352
AD0000 Other Ceiling Finishes Abrasion Resistant
Coatings
12 2010 6 2021 Good $0.000 $352.000 $ 0.005 sf 536 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ 352
AD0000 Other Ceiling Finishes Chemical Resistant
Coatings
10 2010 4 2019 Good $0.000 $352.000 $ 0.006 sf 543 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ 352
AD0000 Other Ceiling Finishes Concrete and Masonry
Coatings
12 2010 6 2021 Good $0.000 $352.000 $ 0.010 sf 538 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ 352
AD0000 Other Ceiling Finishes Elastomeric Coatings 25 2010 19 2034 Good $0.000 $0.000 $ 0.015 sf 539 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Other Ceiling Finishes Fire Resistant Paint 25 2010 19 2034 Good $0.000 $0.000 $ 0.025 sf 541 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Other Ceiling Finishes Graffiti Resistant
Coatings
10 2010 4 2019 Good $0.000 $352.000 $ 0.006 sf 544 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ 352
AD0000 Other Ceiling Finishes High Build Glazed
Coatings
12 2010 6 2021 Good $0.000 $352.000 $ 0.005 sf 537 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
$ 352
AD0000 Other Ceiling Finishes Intumescent Paint 25 2010 19 2034 Good $0.000 $0.000 $ 0.035 sf 542 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Other Ceiling Finishes Linear Metal 30 2010 24 2039 Good $0.000 $0.000 $ 0.023 sf 531 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Other Ceiling Finishes Linear Wood 35 2010 29 2044 Good $0.000 $0.000 $ 0.020 sf 534 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Other Ceiling Finishes Mirror Panels 30 2010 24 2039 Good $0.000 $0.000 $ 0.040 sf 532 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Other Ceiling Finishes Suspended Decorative
Grids
25 2010 19 2034 Good $0.000 $0.000 $ 0.006 sf 535 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Other Ceiling Finishes Textured Gypsum
Panels
45 2010 39 2054 Good $0.000 $0.000 $ 0.020 sf 533 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Other Ceiling Finishes Textured Plastic 25 2010 19 2034 Good $0.000 $0.000 $ 0.015 sf 540 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Plaster Ceiling Finishes 45 2010 39 2054 Good $0.000 $0.000 $ 0.025 sf 525 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
AD0000 Veneer Plaster Finishes 35 2010 29 2044 Good $0.000 $0.000 $ 0.014 sf 527 Level Floor: Contains Music Rooms (11) and storage closets (9) with
a designated 16 person Occupant Load. Finishes include older sheet
carpet, plaster painted walls and ceilings.
D SERVICES $ - $ 40 $ - $ 20 $ 300 $ - $ 18 $ - $ - $ 335 $ - $ - $ - $ - $ 20 $ 14 $ - $ - $ - $ 201
D10 Conveying $ -
D1010 Elevators and Lifts
AD0000 Elevators Commercial 35 1974 3 2018 Fair Functiona
lity
3-Not Yet
Critical
$ 60 $ 60 $ 60.000 LS 1 The building is equipped with the original hydraulic elevator by
Montgomery. The elevator has a capacity of 1350 kg. Allow for elevator
modernization in the short term as parts may become obsolete and repairs
may become costly.
$ 60
AD0000 Elevators Cab Finishes 18 1994 3 2018 Fair Appearan
ce
4-
Recomm
ended
$ 10 $ 10 $ 10.000 LS 1 Elevator cab is finished with carpet, laminate wall panels, and acrylic
ceiling panels. The carpet is worn.
$ 10
D1030 Other Conveying
SystemsAD0000 Dumbwaiters 35 1948 -33 1982 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 12.000 LS The Cober dumbwaiter at the Centre Wing/Service Wing is original and
currently non-operational. It has a capacity of 227 kg. No allowances are
carried to renovate the equipment.
D20 Plumbing $ -
D2010 Plumbing Fixtures
AD0000 Water Closets 22 1994 8 2023 Good Building
Integrity
4-
Recomm
ended
$ 19 $ 19 $ 1.200 # 16 Washrooms and basement Change Rooms are equipped with American
Standard flush valve water closets.
$ 19
Page 11 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Urinals 22 1994 8 2023 Good Building
Integrity
4-
Recomm
ended
$ 6 $ 6 $ 1.200 # 5 Men's Washrooms and Change Room are equipped with urinals. Flush
valve urinals are replaced with waterless units as needed.
$ 6
AD0000 Lavatories 22 1994 8 2023 Good Building
Integrity
4-
Recomm
ended
$ 14 $ 14 $ 1.000 # 14 Washrooms and basement Change Rooms are equipped with American
Standard vitreous clay lavatories with newer lever type faucets.
$ 14
AD0000 Sinks 22 1994 8 2023 Good Building
Integrity
1-
Currently
Critical
$ 1 $ 1 $ 0.750 # 1 Concrete mop sinks are installed in the Janitor's Rooms. Moderate
staining was noted.
$ 1
AD0000 Sinks 22 1999 5 2020 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.750 # Eight stainless steel sinks with goose neck style faucets are in good
condition at the Kindergarten Classrooms. Allow for longer term
replacement. Cost covered under Interior Finishes component.
$ -
AD0000 Sinks 22 1999 5 2020 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 1.200 # Two precast concrete slop sink with wall faucet are provided at both Slop
Sink Rooms. Cost covered under Interior Finishes component.
$ -
AD0000 Washrooms Barrier Free 22 1999 5 2020 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 # Two unisex, two-piece barrier free Washrooms are installed. Includes
32.5" wide door, extended vanity at 32.5" high, American Standard water
closet with Teck toggle flush, 33" high back and L type bars, painted
gypsum board ceiling with ceramic tiled floor and walls. Cost covered
under Interior Finishes component.
$ -
AD0000 Other Hose Bibs 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.000 LS Standard, non-freeze hose bibs are installed along the exterior walls. $ -
AD0000 Showers 30 1994 8 2023 Good Building
Integrity
4-
Recomm
ended
$ 135 $ 135 $ 15.000 LS 9 Basement Change Rooms are equipped with showers with lever type
faucets.
$ 135
AD0000 Drinking Fountains and
Coolers
20 2010 14 2029 Good Building
Integrity
1-
Currently
Critical
$ 8 $ 8 $ 2.500 # 3 Stainless steel drinking fountains are installed on each floor level.
Fountains were manufactured by Filtrine. The fountains are generally
acceptable for barrier-free use.
$ 8
AD0000 Other Plumbing Fixtures Eyewash 15 1999 -2 2013 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 # Bradley emergency eye wash station is located at the Main Mechanical
Room.
AD0000 Drinking Fountains and
Coolers
20 2007 11 2026 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 # Dual stainless steel wall mounted fixture at Gym corridor is in good
condition.
$ -
AD0000 Drinking Fountains and
Coolers
20 1996 0 2015 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 # Wall mounted, stainless steel drinking fountain located at Level B Hallway
of 1978 Wing.
$ -
AD0000 Other Plumbing Fixtures Eyewash 15 2006 5 2020 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 # Bradley emergency eye wash station is located at the Lab Room B23. $ -
D2020 Domestic Water
DistributionAD0000 Water Supply Pipe 10 1999 -7 2008 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 10.000 LS Copper distribution piping and valves throughout the facility are in good
serviceable condition with minimal noted damage. Allow for longer term
repairs only at 10 year intervals.
AD0000 Water Supply Pipe Main Service 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 LS 4" diameter PVC pipe to 3" diameter copper service complete with by-pass
and Watts (model# 009 RP) backflow preventer. The piping is insulated
with fiberglass and PVC jacket. Minor insulation damage was noted.
AD0000 Water Supply Pipe Main Service 40 2006 30 2045 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 LS 4" diameter PVC pipe at pool tunnel is split to 4" diameter cast iron for the
fire line and 4" diameter copper for the domestic water system. Meter not
located here; drawings indicated meter here.
Page 12 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Water Supply Pipe Plumbing Distribution &
Valves
40 1994 18 2033 Fair Building
Integrity
4-
Recomm
ended
$ 45 $ 45 $ 45.000 LS 1 Copper distribution piping is installed and typically insulated. $ 45
AD0000 Water Supply Pipe Plumbing Distribution &
Valves
5 1961 -50 1965 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS Allowance to commence piping replacements in the South Wing every 5
years.
AD0000 Water Supply Pipe Plumbing Distribution &
Valves
5 1979 -32 1983 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Allowance to commence piping replacements in the North Wing every 5
years.
AD0000 Water Supply Pipe Plumbing Distribution &
Valves
40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 120.000 LS Copper piping throughout the North Addition is in good condition.
AD0000 Water Supply Pipe Plumbing Distribution &
Valves
40 2006 30 2045 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 130.000 LS Copper piping throughout the Athletic Centre is in good condition.
AD0000 Pipe Insulation 40 2006 30 2045 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS Pipe covering, fiberglass with all service jacket, is in good condition at the
Athletic Centre Mechanical Room, stairwells and at the pool tunnel service
areas. The piping is demarked with service type and directional flow as
required. Typical in service areas also.
AD0000 Pipe Insulation 40 2006 30 2045 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.000 LS Pool pipe insulation at heat exchanger HX-2 is omitted on the domestic
cold water service. Allow to add in the short term.
AD0000 Pipe Insulation 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Glycol chilled water supply and return piping are insulated with fiberglass
and PVC jacket.
AD0000 Pipe Insulation 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS Domestic water supply piping is insulated with fiberglass and PVC jacket.
Localized damage at Mechanical Room.
AD0000 Domestic Water Storage
Tanks
40 2005 29 2044 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 29.000 # The vertical steel domestic hot water tank DHWT-2 (serial# 04-219, CRN#
H6839.52T184) is located in the Athletic Mechanical Room. The tank was
relined in 2013 by Hydrastone including new anodes. Manufactured by
Clemmer with 661 Imperial Gallon capacity each.
AD0000 Domestic Water Storage
Tanks
40 2005 29 2044 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 29.000 # The vertical steel domestic hot water tank DHWT-1 (serial# 05-269, CRN#
M1073.523) is located in the Athletic Mechanical Room. The tank was
relined in 2013 by Hydrastone including new anodes.
AD0000 Domestic Water Storage
Tanks
40 1999 23 2038 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 # Manufacture and capacity is unknown. Inspected and relined in 2014 by
Hydrastone. Insulated with fiberglass and PVC jacket.
AD0000 Domestic Water Storage
Tanks
40 1987 11 2026 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 # Drummond Welding & Steel Works tank at Boiler Room is in fair condition.
Vertical hot water storage tank was inspected with new anodes installed in
2013 by Hydrastone.
$ -
AD0000 Domestic Water Storage
Tanks
40 1978 2 2017 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 # Clemmer Steelcraft tank at North Wing Level A Mechanical Room is in fair
condition. Inspected in 2013 by Hydrastone. Includes small B&G 1/3-HP
circulating pump. Allow for refurbishment/repairs then replacement.
$ -
D2030 Sanitary Waste
AD0000 Waste and Vent Pipe Sewage Pumps &
Tanks
20 1994 3 2018 Fair Building
Integrity
3-Not Yet
Critical
$ 15 $ 15 $ 5.000 # 3 Three sump pumps with alarm panels by Scarborough Pumps are
installed in the basement Mechanical Room. Pump functions (i.e. storm,
sanitary) are not labelled (maintenance).
$ 15
AD0000 Waste and Vent Pipe Sewage Pumps &
Tanks
35 1979 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 LS North Wing tank is in fair condition.
AD0000 Waste and Vent Pipe Sewage Pumps &
Tanks
20 1999 3 2018 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 # 1999 Kitchen pumps are in fair condition. Listed as UP-10 and UP-11, 3-
HP motors by Barnes.
$ -
AD0000 Waste and Vent Pipe Sewage Pumps &
Tanks
35 1999 18 2033 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 40.000 LS 1999 Kitchen grey water tank is in fair condition. $ -
AD0000 Waste and Vent Pipe Grease Interceptor 35 1999 18 2033 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 45.000 LS Kitchen Acorn grease interceptor is in fair condition. $ -
AD0000 Waste and Vent Pipe Sewage Pumps &
Tanks
20 2006 10 2025 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 7.500 # Sanitary pit, Plad wall control panel and sump pumps SP-3 and SP-4 are
located in the service tunnel of the Pool. Tank and pumps are not
accessible. Waste is ejected out to 4" pipe out south wall.
$ -
AD0000 Waste and Vent Pipe Sewage Pumps &
Tanks
20 2006 10 2025 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 7.500 # Sanitary pit, Plad wall control panel and sump pumps SP-3 and SP-4 are
located in the service tunnel of the Pool. Tank and pumps are not
accessible. Waste is ejected out to 4" pipe out south wall.
$ -
AD0000 Waste and Vent Pipe Sewage Pumps &
Tanks
20 1979 -17 1998 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 8.000 # Boiler Room pumps are in fair condition. Allow to update in short term.
AD0000 Waste and Vent Pipe Sewage Pumps &
Tanks
35 1979 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 35.000 LS Boiler Room tank is in fair condition. Allow to update in short term.
Page 13 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Waste and Vent Pipe 40 1974 3 2018 Fair Building
Integrity
3-Not Yet
Critical
$ 20 $ 20 $ 20.000 LS 1 ABS sanitary is installed to the cast iron mains. Allow for repairs and
localized replacement as needed.
$ 20
AD0000 Elevator Sump 25 1999 8 2023 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 LS Elevator sump pump UP-12 is concealed from view. $ -
D2040 Rainwater Drainage
AD0000 Pipe 40 1999 23 2036 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 LS Cast iron storm drainage piping is used throughout the building. The
drainage piping, and all associated fittings, are in good condition. Piping is
uninsulated on vertical runs and insulated at horizontal runs at roof deck.
No allowances carried over the study period.
AD0000 Drain 25 1999 8 2021 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 1.500 # Control flow roof drains are installed over the main roof areas. The drains
are in good condition. Vegetation cleanout is required; considered an
operational/maintenance item.
$ -
AD0000 Pipe 40 1999 23 2036 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS Cast iron storm drainage piping is used throughout the building. The
drainage piping, and all associated fittings, are in good condition. Piping is
uninsulated on vertical runs and insulated at horizontal runs at roof deck.
No allowances carried over the study period.
AD0000 Drain 25 1999 8 2021 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.600 # Control flow roof drains are installed over the main roof areas. The drains
are in good condition. Vegetation cleanout is required; considered an
operational/maintenance item.
$ -
AD0000 Pipe 40 2006 30 2043 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS Cast iron storm drainage piping is used throughout the building. The
drainage piping, and all associated fittings, are in good condition. Piping is
uninsulated on vertical runs and insulated at horizontal runs at roof deck.
No allowances carried over the study period.
AD0000 Drain 25 2006 15 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.600 # Control flow roof drains are installed over the main roof areas. The drains
are in good condition. Vegetation cleanout is required; considered an
operational/maintenance item.
$ -
AD0000 Waste Piping Equipment Submersible Pump &
Control
20 1999 3 2018 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Storm weeping tile pit, sand settling pit, Plad wall control panel and sump
pumps SP-1 and SP-2 are located in the serviced tunnel of the Pool. Tank
and pumps are not accessible.
$ -
D2090 Other Plumbing
SystemsAD0000 Compressed Air Systems Air Compressors 25 1995 4 2019 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.500 LS Devilbiss, dual type compressor is in good condition. $ -
AD0000 Pool and Fountain
Equipment
Balancing Tank 30 2006 20 2035 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 30.000 LS Balancing tank is manufactured by Nemato (model# NBT-60-1460) and
has a 1460 US Gallon capacity.
AD0000 Pool and Fountain
Equipment
Waste Water Holding
Tank
30 2006 20 2035 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.500 LS Waste water holding tank is constructed from polyethylene and is
manufactured by Bonar.
AD0000 Pool and Fountain
Equipment
Chlorine Tank & Pump 15 2006 5 2020 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.500 LS Chlorine holding tank is constructed from polyethylene and is
manufactured by Bonar.
$ -
AD0000 Pool and Fountain
Equipment
Muriatic Acid Tank &
Pump
15 2006 5 2020 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.500 LS Muriatic Acid holding tank is constructed from polyethylene and is
manufactured by Bonar.
$ -
AD0000 Pool and Fountain
Equipment
Fluid Strainers 30 2006 20 2035 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 LS National Line fluid straining systems by US Filter.
AD0000 Pool and Fountain
Equipment
Dosing Pumps 7 2006 -3 2012 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 1.500 LS Chemtrol chemical feed control panel (model# PC3000) and Stennec
dosing pumps are in fair condition.
AD0000 Pool and Fountain
Equipment
Water Fill 30 2006 20 2035 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 LS Fill line has separate meter and backflow preventer as required.
AD0000 Pool and Fountain
Equipment
Sand Filters 30 2006 20 2035 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 55.000 LS Three high rate sand filters by Nemato (model# NFS-34-A-153) are in
good condition.
Page 14 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Pool and Fountain
Equipment
Circulating Pumps 20 2006 10 2025 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS Two 15-HP Armstrong vertical in-line circulating pumps are in good
condition. Equipped with Baldor 15-HP motors at 85% efficiency.
$ -
AD0000 Pool and Fountain
Equipment
Circulating Pumps 20 2006 10 2025 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS Two 15-HP Armstrong vertical in-line circulating pumps are in good
condition. Equipped with Baldor 15-HP motors at 85% efficiency.
$ -
AD0000 Pool and Fountain
Equipment
Eyewash 20 2006 10 2025 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.000 LS Bradley emergency eye wash station is located at the Main Mechanical
Room.
$ -
AD0000 Pool and Fountain
Equipment
Pool Tunnel Supply Fan 20 2006 10 2025 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.500 LS 3/4 HP air supply fan at tunnel is in good condition. The Controller was
not operational however. Allow for verification of system.
$ -
AD0000 Pool and Fountain
Equipment
Pool Supply Air Ducting 30 2006 20 2035 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 LS Conventional supply air ducting is installed at the pool tunnel.
AD0000 Pool and Fountain
Equipment
Vacuum Breaker 20 2006 10 2025 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.500 LS VacAlert Industries vacuum breaker device (VAC 2000) is in good
condition.
$ -
AD0000 Pool and Fountain
Equipment
Pool Piping & Fittings 30 2006 20 2035 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 150.000 LS PVC supply and return piping, copper fill piping, back-flow preventer, etc.
are in good condition. Allow for long term replacements.
AD0000 Pool and Fountain
Equipment
Pool Basin 30 2006 20 2035 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 75.000 LS Concrete pool basin is in good condition with localized vertical wall cracks
(6). Some cracks were active. Allow for repairs to basin in short term and
longer term major repairs.
AD0000 Pool and Fountain
Equipment
Railings 30 2006 20 2035 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.000 LS Painted steel guard and access ladders at pool tunnel are in good
condition. Height of guard at 42" as required.
AD0000 Chemical Treatment 15 2006 5 2020 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 # Pall (model# T910031, serial# HH) inline filter and Ashland 2 gallon pot
feeder (model# VTF-2HP) is located at the Athletic Centre Mechanical
Room. Serves the Athletic and South Wing heating system.
$ -
AD0000 Chemical Treatment 15 2006 5 2020 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 # Pall (model# T910031, serial# HH) inline filter and Ashland 2 gallon pot
feeder (model# VTF-2HP) is located at the Pool Tunnel area.
$ -
AD0000 Chemical Treatment 15 1999 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 # Pall (model# T910031, serial# HH) inline filter and Ashland 2 gallon pot
feeder (model# VTF-2HP) is located at the 1999 Mechanical Room.
AD0000 Chemical Treatment 15 1999 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 7.000 # Chemical sulphite and alkalinity builder boiler chemical systems.
AD0000 Chemical Treatment 15 1999 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.500 # Inline filter and Neptune by-pass feeder located in Mechanical Room.
AD0000 Chemical Treatment 15 1999 -2 2013 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.500 # Filterite inline filter and Ashland 2 gallon pot feeder (model# VTF-2HP) is
located at the Main Mechanical Room. Serves the heating system.
AD0000 Chemical Treatment 15 1999 -2 2013 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.500 # Filterite inline filter and Ashland 2 gallon pot feeder (model# VTF-2HP) is
located at the Main Mechanical Room. Serves the glycol system.
Page 15 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Chemical Treatment 20 1999 3 2018 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 10.000 # Glycol holding tank and control panel are in fair condition overall. $ -
AD0000 Chemical Treatment 20 1999 3 2018 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 10.000 # Glycol holding tank, Leeson motor and control panel are in good condition
overall.
$ -
D30 HVAC $ -
D3010 Energy Supply
AD0000 Gas Supply 15 2006 5 2020 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.000 LS Gas supply piping throughout the facility is in good condition where
observed. Allow for full repainting at the Boiler Room and Pool tunnel
areas due to wear and corrosion. Replacement of piping is carried with
the equipment being served by it.
$ -
D3020 Heat Generation
AD0000 Steam Boilers Gas-Fired 40 1966 -10 2005 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 135.000 # The Upper School is heated by two 4,500 MBH York Shipley, three-pass
Scottish Marine steam type boilers. The 1966 gas-fired boilers are located
in the main Mechanical Room. Allow for future refurbishment in 5 years.
The boilers were re-tubed in 2006 and burners were replaced in 2007 with
Fuel Master model# CG-165. System apparently operates at 85%
efficiency as reported.
AD0000 Hot Water Boilers Gas-Fired 25 2005 14 2029 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 27.000 # Laars gas-fired hot water boilers for building heating (model#
PNCH1000NACN2CXX, serial# C05156471 and 2) are rated at 999.96
MBH input and 839.20 MBH output. Located at the Athletic Centre
Mechanical Room. The boilers are equipped with a EMC (model# S-112)
sequencer control.
$ -
AD0000 Hot Water Boilers Gas-Fired 25 2005 14 2029 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 # Laars gas-fired hot water boiler for domestic hot water (model# , serial# )
is located at the Athletic Centre Mechanical Room. The data label was
damaged.
$ -
AD0000 Hot Water Boilers Gas-Fired 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 # Teledyne Laars gas-fired hot water boiler for domestic hot water (model#
VW0715INC1CC , serial# C98K04444) is located at the North 1999
Addition Mechanical Room. Rated at 715 MBH input and 579 MBH
output.
$ -
AD0000 Hot Water Boilers Gas-Fired 25 2005 14 2029 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 35.000 # RBI 8900 Series (model# HW1050NOE1COG, serial# 050435496)
domestic hot water boiler at Main Boiler Room is in good condition. Rated
at 1050 MBH input. Denoted as DHWH #2.
$ -
AD0000 Hot Water Boilers Gas-Fired 25 2013 22 2037 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 # Hydrotherm (model# KN-2, serial# KN2-2013) gas-fired direct-vent boiler
complete with inline General Filtration filter and Neptune by-pass feeder.
Serves a newer heating loop. Also includes a small expansion tank and
two B&G fractional horsepower circulating pumps.
AD0000 Hot Water Boilers Gas-Fired 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 37.000 # Teledyne Laars gas-fired hot water boilers for building heating (model#
HH1670IN11K1CCAL, serial# C98K04442 and C98K04443) are rated at
1,670 MBH input and 1352 MBH output. Located at the North 1999
Addition Mechanical Room. The boilers are equipped with a sequencer
control.
$ -
AD0000 Hot Water Boilers Gas-Fired 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 # Teledyne Laars gas-fired hot water boilers for domestic water heating
(model# VW0715IN11C1CCXX) is rated at 715 MBH input and 579 MBH
output. Located at the North 1999 Addition Mechanical Room.
$ -
AD0000 Hot Water Boilers Gas-Fired 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 37.000 # Teledyne Laars gas-fired hot water boilers for building heating (model# HH
1200) are rated at 1,200 MBH input and 972 MBH output. Located at the
Junior School Mechanical Room. The boilers are equipped with a
sequencer control. The boilers serve a two pipe distribution system to the
various radiant heaters and panels.
$ -
AD0000 Hot Water Boilers Gas-Fired 15 2005 4 2019 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 16.000 # Rheem gas-fired hot water boiler for domestic hot water (model# G100-75
, serial# RRNG 0205D06056) is located at the Junior School Mechanical
Room. Rated at 75 MBH input.
$ -
AD0000 Other Heat Generation
Systems
Condensate Return
Feedwater Tank
25 1993 2 2017 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 35.000 # Condensate return tank is located in the Main Mechanical Room.
Includes older feed water and condensate return pumps.
$ -
AD0000 Other Heat Generation
Systems
Heating Controls 25 1979 -12 2003 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 # Allow to update older pneumatic controls, compressor and dryer at main
Mechanical Room to electric type (BAS).
AD0000 Other Heat Generation
Systems
Heating Controls 25 1979 -12 2003 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 # Allow to update older pneumatic controls, DeVilbiss compressor and dryer
at main Mechanical Room to electric type (BAS).
Page 16 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Other Heat Generation
Systems
Heating Controls 25 1979 -12 2003 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 # Allow to update older pneumatic controls, DeVilbiss compressor and dryer
at main Mechanical Room to electric type (BAS).
AD0000 Other Heat Generation
Systems
Heating Controls 25 1985 -6 2009 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 # Allow to update older pneumatic controls, compressor and dryer at North
Mechanical Room to electric type (BAS).
AD0000 Other Heat Generation
Systems
Condensate Tank 25 1979 -12 2003 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 7.500 # Condensate tank is located in the North Mechanical Room Level A.
AD0000 Other Heat Generation
Systems
General Utility Pumps 20 1994 5 2020 Good Building
Integrity
1-
Currently
Critical
$ 12 $ 12 $ 6.000 # 2 Two 25 HP heat pump pumps are installed in the Penthouse. $ 12
AD0000 Other Heat Generation
Systems
General Utility Pumps 15 1994 5 2020 Good Building
Integrity
1-
Currently
Critical
$ 6 $ 6 $ 2.000 # 3 Two 10 HP condenser water pumps are installed in the Penthouse. $ 6
AD0000 Other Heat Generation
Systems
Expansion Tank 35 2006 25 2040 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.000 # Floor mounted Expanflex steel expansion tank at Athletic Centre
Mechanical Room is in good condition.
AD0000 Other Heat Generation
Systems
Expansion Tank 35 1999 18 2033 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Two expansion tanks are located at the main Mechanical Room. $ -
AD0000 Other Heat Generation
Systems
Expansion Tank 35 1948 -33 1982 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.000 LS Remove abandoned expansion tank, piping and refrigeration equipment in
Boiler Room.
AD0000 Other Heat Generation
Systems
Expansion Tank 35 1996 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.000 LS New vertical expansion tank at Boiler Room is in good condition. $ -
AD0000 Other Heat Generation
Systems
Liquid-to-Liquid Heat
Exchangers
35 2006 25 2040 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 19.000 # HX-1, Armstrong unit located in Pool Mechanical Room. Uses hot water
from the main boilers.
AD0000 Other Heat Generation
Systems
Plate type heat
exchanger
35 1994 13 2028 Good Building
Integrity
1-
Currently
Critical
$ 20 $ 20 $ 20.000 # 1 An Alfa Laval plate type heat exchanger is installed in the Penthouse. $ 20
AD0000 Other Heat Generation
Systems
Liquid-to-Liquid Heat
Exchangers
35 2006 25 2040 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 # Glycol heat transfer by steel shell and tube heat exchanger is located at
the Penthouse Mechanical Room.
AD0000 Other Heat Generation
Systems
Liquid-to-Liquid Heat
Exchangers
35 1979 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 21.000 # The North Wing is fed by steam from the main boilers and heats the water
for the 1970 Wing. This unit is quite dated.
AD0000 Other Heat Generation
Systems
Liquid-to-Liquid Heat
Exchangers
35 1966 -15 2000 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 30.000 # The Main Boiler Room unit is operated by steam from the main boilers and
heats the water for the Art House and 3rd and 4th floors of the Centre
Wing. This unit is quite dated.
AD0000 Heating Supply
Insulation
40 1974 2 2017 Fair Energy 3-Not Yet
Critical
$ 20 $ 20 $ 20.000 LS 1 Chilled water piping for cooling is not insulated. Heating piping is insulated
with fibreglass and PVC or canvas wrap. Provide insulation on cooling
piping.
$ 20
AD0000 Heating Supply
Insulation
40 1978 2 2017 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 50.000 LS All heating supply and return piping at the 1978, 1926, 1948 areas are a
combination of fiberglass, asbestos, cellulose all with and without
asbestos fittings. Replace all in longer term as part of retrofit. Includes
pipe chases.
$ -
AD0000 Heating Distribution
Piping
40 1950 -26 1989 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 130.000 LS The distribution piping for the steam and hot water distribution piping is in
need of updating due to age and problematic issues. Allow for staging the
replacement over 10 years as opposed to localized repairs. This includes
the tunnel, North Wing and Centre and South Wings.
AD0000 Heating Distribution
Piping
Valves 40 1950 -26 1989 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 75.000 LS Older stem valves are in need of updating at main Boiler Room and
tunnels. Approximately 65.
AD0000 Heating Distribution
Piping
Valves 40 1950 -26 1989 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 75.000 LS Older stem valves are in need of updating at main Boiler Room and
tunnels. Approximately 65.
Page 17 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Other As-Built Drawings 15 1978 -23 1992 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 LS Partial as-built drawings are available. As there has been significant
changes to systems over the years, including building interior layouts, it is
recommended that a complete set of as-built drawings be prepared
including site, architectural, mechanical, electrical and structural.
D3030 Refrigeration
AD0000 Centrifugal Water
Chillers
Air Cooled Water Chiller 25 1999 8 2023 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 245.000 # McQuay (model# ALR145EY37, serial# 58L8136501) reciprocating type
chiller is rated at 140 tons with 600-V, 3-P,4-W service. The chiller serves
the entire school through the two air handling units. The chiller is
equipped with four 40-HP compressors using HCFC-22 refrigerant
(phased out in 2020). Details on compressor replacement are unknown.
Piping of chiller is insulated with aluminum cover.
$ -
AD0000 Centrifugal Water
Chillers
Compressors 5 2015 4 2019 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 60.000 # Compressor allowance. $ -
AD0000 Centrifugal Water
Chillers
Air Cooled Water Chiller 25 1999 8 2023 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 # The steel framed support for the chiller is in good condition with minor
surface corrosion. Refurbish when replacing chiller. Steel guard at
platform is slightly less than the required 42"; no allowances carried for
rectification.
$ -
AD0000 Centrifugal Water
Chillers
Air Cooled Water Chiller 25 1999 8 2023 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 220.000 # McQuay reciprocating type chiller is rated at 120 tons with 600-V, 3-P,4-W
service. The chiller serves the 1999 Wing and the air handling unit in the
North Mechanical Room that serves the Library and parts of the 1979
Wing. The chiller has four 40-HP compressors using HCFC-22 refrigerant
(phased out in 2020). Details on compressor replacement are unknown.
Piping of chiller is insulated with aluminum cover.
$ -
AD0000 Centrifugal Water
Chillers
Compressors 5 2015 4 2019 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 80.000 # Compressor allowance. $ -
AD0000 Other Kitchen Refrigeration 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.000 # Blanchard Ness (model# TOUS) units located externally are in fair
condition.
$ -
AD0000 Cooling Towers &
Evaporative Coolers
25 1994 3 2018 Fair Functiona
lity
3-Not Yet
Critical
$ 30 $ 30 $ 30.000 # 1 A BAC cooling tower is installed on the roof. No manufacturer's
information was available.
$ 30
D3040 HVAC Distribution
AD0000 Air Distribution Air Handling Units,
packaged indoor
25 1994 3 2018 Fair Functiona
lity
3-Not Yet
Critical
$ 20 $ 20 $ 5.000 # 4 McQuay split system fancoil units are installed throughout the building.
Units are controlled by individual thermostats. The units vary in size. Units
are factory charged with R22 refrigerant. Heating and cooling is provided
hydronically.
$ 20
AD0000 Air Distribution Air Handling Units,
packaged indoor
25 2010 19 2034 Good Functiona
lity
4-
Recomm
ended
$ 20 $ - $ 20.000 # 1 A Johnson/McQuay air handling unit is located in the ceiling of the second
floor Corridor (model# DSH024A1E1AAA0AA, serial# 10030025C). The
unit is factory charged with R410a refrigerant. Vibration insulators are
recommended on the hangars.
AD0000 Air Distribution Air Handling Units,
packaged indoor
25 1994 3 2018 Fair Functiona
lity
3-Not Yet
Critical
$ 100 $ 100 $ 50.000 # 2 Air handling units 1B and 2B by Engineered Air, located in the Penthouse,
provide fresh air to the split systems (model#UPW363C, serial#
19579AHU1B, 19579AHU2B).
$ 100
AD0000 Air Distribution Air Handling Units,
packaged indoor
25 1994 3 2018 Fair Functiona
lity
3-Not Yet
Critical
$ 10 $ 10 $ 10.000 # 1 Heat pump 7, located in the Penthouse, is by Snyder General (model#
LHP22CK, serial# 7YF0348703).
$ 10
AD0000 Air Distribution Air Handling Units,
packaged indoor
25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 125.000 # McQuay AHU-3 (model# CAH035SDAC) provides tempered air to the
Classrooms. Includes circulating pump.
$ -
AD0000 Air Distribution Air Handling Units,
packaged indoor
25 2003 12 2027 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 100.000 # Packaged air handling unit at North Mechanical Room was rebuilt in 2003.
Services portions of the 1979 Wing including the Library. McQuay
(model# CAH025G0AM).
$ -
AD0000 Air Distribution Rooftop package, gas-
fired heating, electric
cooling
25 2006 15 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 70.000 # Packaged unit for new double Gym is rated at 30-Ton. Aaon Coil
Products (model# CA0984, serial# 200506-CCC) central air conditioner.
Listed as RTU-3.
$ -
AD0000 Air Distribution Exposed ductwork
insulation at roof levels
25 2006 15 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 8.500 # Aluminized insulated ducting jacket at roof level is in good condition.
There is localized damage at RTU-3. Allow for repairs and longer term
replacement.
$ -
AD0000 Air Distribution Rooftop package, gas-
fired heating, electric
cooling
25 2006 15 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 37.000 # Aaon packaged unit for old single Gym is rated at 20-Ton. Listed as RTU-
1. Label is illegible.
$ -
Page 18 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Air Distribution Rooftop package, gas-
fired heating, electric
cooling
25 2006 15 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 55.000 # Packaged unit for VAV for Athletic Centre is rated at 22-Ton. Aaon Coil
Products (model# CA0532, serial# 200506-CCC) central air conditioner.
Listed as RTU-2.
$ -
AD0000 Air Distribution Rooftop package, gas-
fired heating, electric
cooling
25 2006 15 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 37.000 # Packaged unit for Pool is rated at 20-Ton. Air Wise (model# TBA-650/RA,
serial# CN-3888) with indirect gas fired heater. Listed as RTU-4.Includes
Aaon (model# CA1118, serial# 200506-CCC) heating/cooling section.
$ -
AD0000 Air Distribution Make-up Air Unit, gas-
fired
25 2006 15 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 33.000 # Make-up air unit for Athletic Centre is rated at 10-Ton. Air Wise Custom
(model# TBA-250/DX-C8, serial# CN-388).
$ -
AD0000 Air Distribution Rooftop package, gas-
fired heating, electric
cooling
25 2006 15 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 17.000 # Aaon packaged unit for main entrance foyer at Athletic Centre is rated at 4-
Ton cooling. Label is illegible. Listed as RTU-5.
$ -
AD0000 Air Distribution Rooftop package, gas-
fired heating, electric
cooling
25 2002 11 2024 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 57.000 # RTU-6 packaged unit for Assembly Hall is in good condition. Rated at 25-
Ton cooling. York (model# D2CG300N3205058ECA, serial#
NCLM029779) is charged with R22 refrigerant. Rated at 400 MBH input.
$ -
AD0000 Air Distribution Rooftop package,
electric cooling
25 1993 2 2015 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 30.000 # Carrier Weathermaker 1 (model# 50LJOO8510) packaged unit for South
Wing was relocated to Athletic Centre and serves Computer Rooms C47
and C48. Referred to as RTU-10. Charged with R22 refrigerant.
$ -
AD0000 Air Distribution Rooftop package, gas-
fired heating, electric
cooling
25 2003 12 2025 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 31.000 # Packaged unit for Business Office is in good condition. Rated at 12.5 Ton
cooling.
$ -
AD0000 Air Distribution Rooftop package,
electric cooling
25 1984 -7 2006 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 # Packaged unit for Day School Office is in fair condition but has reached
the end of its useful service life. Unitary Products Sunline 2000 (model#
D7CG060NO9925A, serial# NGMM084156, 125 MBH heating and R22
refrigerant charge. Listed as RTU7 at roof of 1948 Addition. Ductwork is
fed below to the Offices.
AD0000 Air Distribution Ground Level package,
electric cooling
25 2012 21 2034 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 # Goodman (model# CPG0601403BXXXBA, serial# 1202160927) is factory
charged with R410A, with heating input of 138 MBH, output of 110 MBH .
Unit serves the IT Room and Office.
AD0000 Air Distribution Rooftop package,
electric cooling
25 2005 14 2027 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 # RTU-9, Johnson Controls Unitary Products (model# D2EZ036A06C,
serial# W1F3791633) packaged rooftop unit is rated at 3-Ton and factory
charged with R-410A.
$ -
AD0000 Air Distribution Fans, utility, supply air 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.000 # Barry Blower supply air fan by Penn is installed for the air handling unit in
the Mechanical Room. Has a 5-HP Baldor motor with NEMA nominal
efficiency of 89.5%.
$ -
AD0000 Air Distribution Fans, utility, supply air 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 # Supply fan F-J1 serves the Classrooms. It is manufactured by Barry
(model# 402 ESI, serial# 48M00039) rated at 11530 L/S and 7.46 kW)
complete with Baldor Super-E 10-HP motor and variable speed drive. Fan
is located in Junior School Mechanical Room.
$ -
AD0000 Air Distribution Fans, utility, supply air 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 # Supply fan F-J2 serves the Gym and Lunch area. It is manufactured by
Barry (model# ESI) rated at 762 L/S and 1.50 kW) complete with variable
speed drive. Data tag and motor were not accessible. Fan is located in
Junior School Mechanical Room.
$ -
AD0000 Air Distribution Ducting 40 1994 18 2033 Good Building
Integrity
4-
Recomm
ended
$ 75 $ 75 $ 75.000 LS 1 Conventional ductwork, standard supply air grilles and parabolic diffusers
are installed throughout. Some exposed ductwork is painted.
$ 75
AD0000 Air Distribution Ducting 30 2006 20 2035 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Circular ducting for pool area is located within the pool service tunnel.
Minor wear was noted. Allow for longer term replacement.
AD0000 Air Distribution Ducting 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.900 LS Aluminized insulated ducting jacket at roof level is in good condition. $ -
AD0000 Air Distribution Fresh Air 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 LS Fresh air for combustion is provided for the Mechanical Room as required.
Page 19 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Air Distribution Fans, centrifugal type 20 1999 3 2018 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.000 # Penn Zephyr transfer fans are located throughout the building. The fans
are in good condition. Fans are controlled by Canarm dial type
thermostats. Fans are rated at approximately 200 L/s each.
$ -
AD0000 Air Distribution Fans, centrifugal type 20 1994 3 2018 Fair Functiona
lity
4-
Recomm
ended
$ 6 $ 6 $ 2.000 # 3 Greenheck upblast exhaust fans are installed on the roof and south
elevation adjacent to the cooling tower.
$ 6
AD0000 Air Distribution Fans, centrifugal type 20 1999 3 2018 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.000 # Penn Zephyr/Carnes transfer fans are located throughout the building.
The fans are in good condition. Fans are controlled by Canarm dial type
thermostats. Fans are rated at approximately 200 L/s each. Model#
V1DK06F3A1CL20S.
$ -
AD0000 Air Distribution Fans, centrifugal type 20 1999 3 2018 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.000 # Standard downblast and upblast type roof exhaust fans are installed. The
fans are manufactured by Penn and are in fair condition. Includes EF-U1
to EF-U12. Fans are rated at 40 to 600 L/s each.
$ -
AD0000 Air Distribution Fans, centrifugal type 20 1979 -17 1998 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.000 # Older Greenheck downblast roof exhaust fans at 1979 Addition. Replace
in short term.
AD0000 Air Distribution Fans, utility type 25 1979 -12 2003 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.300 # Older utility fan at flat roof is in fair condition.
AD0000 Air Distribution Fans, utility type 25 1990 -1 2014 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 17.000 # Older Penn exhaust fan, Delhi (model# 207) exhaust fan for adjacent
rooms, intake air louver (no damper control) and ducting. Allow to verify
all at Garage and add auto CO detection devices.
$ -
AD0000 Air Distribution Fans, downblast 25 1961 -30 1985 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.300 # Older downblast roof fan at flat roof is in poor condition.
AD0000 Air Distribution Fans, centrifugal type 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.300 # Penn fractional horsepower upblast and downblast utility fans, EF-U3, EF-
U4, EF-U6, EF-U7 at flat roof are in fair condition. EF-U1 is located in the
Mechanical Room.
$ -
AD0000 Air Distribution Fans, centrifugal type 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.300 # Penn fractional horsepower upblast and downblast utility fans, EF-U3, EF-
U4, EF-U6, EF-U7 at flat roof are in fair condition. EF-U1 is located in the
Mechanical Room.
$ -
AD0000 Air Distribution Fans, centrifugal type 25 1999 8 2023 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.000 # Penn Fumex sideblast utility fan EF-U5 at Kitchen is in good condition. $ -
AD0000 Air Distribution Fans, centrifugal type 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 18.000 # Gymnasium ceiling fans by Leading Edge are rated at 10000 L/s or
21,190 CFM each.
$ -
AD0000 Air Distribution Fans, destratification 20 2002 6 2021 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.000 # Destratification ceiling fans at Assembly Hall are in good condition. Dial
controls are located at stage.
$ -
AD0000 Air Distribution Fans, through-wall 20 1975 -21 1994 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Older wall exhaust fan at Boiler Room. Allow for replacement and
verification of ventilation performance in immediate term.
AD0000 Air Distribution Fans, through-wall 20 2007 11 2026 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 # Rosemex heater and Carnes 1/20 HP exhaust fan at Gym Storage Room
is in good condition.
$ -
AD0000 Air Distribution Fans, through-wall 20 2007 11 2026 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 1.200 # Carnes 1/20 HP exhaust fan at Elevator Machine Room is in good
condition. Denoted as TF-4.
$ -
AD0000 Air Distribution Ducts 40 2006 30 2045 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 215.000 LS Galvanized ducting is exposed in most locations. No issues noted.
AD0000 Air Distribution Air Terminal Units 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 1.600 # VAV boxes are installed at the supply air ductwork throughout the served
areas of the main floor. The boxes are connected to the BAS. Systems are
operating adequately but further investigation is required; cost carried
under balancing.
$ -
AD0000 Air Distribution Air Terminal Units 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 1.600 # VAV boxes are installed at the supply air ductwork throughout the served
areas of the main floor. The boxes are connected to the BAS. Systems are
operating adequately but further investigation is required; cost carried
under balancing.
$ -
AD0000 Air Distribution Air Terminal Units 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 1.600 # VAV boxes are installed at the supply air ductwork throughout the served
areas of the second floor. The boxes are connected to the BAS. Systems
are operating adequately but further investigation is required; cost carried
under balancing.
$ -
AD0000 Air Distribution Air Outlets and Inlets 30 1999 13 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 30.000 LS Standard 2'x2' supply diffusers, open perimeter and louvered return grilles
are in good condition. Allow for verification of return air quantity and
locations in short term.
$ -
Page 20 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Air Distribution Air Outlets and Inlets 35 2006 25 2040 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 LS The Athletic Centre Mechanical Room is equipped with a fresh air gravity
duct for the combustion air requirements of the gas-fired boilers as
required.
AD0000 Special Exhaust Systems Kitchen Ventilation 25 1999 8 2023 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS Stainless steel exhaust hood in the Kitchen is in good condition. It is
equipped with a grease extractor. Replace in longer term with wall
exhaust fan.
$ -
AD0000 Other HVAC Distribution
Systems
Breechings, Chimneys
and Stacks
30 2006 20 2035 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS Boiler breeching at the Athletic Centre Mechanical Room is constructed
with rated B-vent sections. The ducting is directed vertically off of the three
boilers.
AD0000 Other HVAC Distribution
Systems
Breechings, Chimneys
and Stacks
50 1948 -18 1997 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 85.000 LS Boiler breeching at the main Boiler Room is constructed with welded metal
sections and suspected to be insulated with asbestos materials.
AD0000 Other HVAC Distribution
Systems
Breechings, Chimneys
and Stacks
30 1999 13 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 12.000 LS Boiler breeching and stacks at Mechanical Room are in good condition. $ -
D3050 Terminal and
Packaged UnitsAD0000 Unitary Air Conditioning
Equipment
Split System 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.500 # ICP condenser ((model# NAC036AKA1) is located at the west side of the
building. Serves the Computer Room.
$ -
AD0000 Unitary Air Conditioning
Equipment
Split System 18 2008 10 2025 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.500 # The units were installed over several years starting in 2004 to 2012.
Sanyo (model# CM1972A, C0971, Cl1271 and CL0971), Fujitsu (model#
AOU9RL2), Unitary Products (model# H4DEO24S06A), Carrier (model#
38BNC018301), Daiken (model# C000932), LG (model# LMO240C) and
Mitsubishi (model# MUY-GE09NA and MUZ0FE09NA) condensers are
located at ground and roof levels throughout the site with wall mounted
evaporator sections. Some units have multiple evaporator sections.
Charged with R410A refrigerant and R22 on older units. Consider
replacement with central packaged heating and cooling unit in longer term
with zone control.
$ -
AD0000 Humidifiers 15 1999 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 28.000 # Dri-Steem (model# GTS-150-CAB) is located in the North 1999 Addition at
the 3rd Floor Mechanical Room and serves the air handling unit. The unit
is not installed correctly according to previous reports. Allow to
activate/modify the installation along with commissioning. Serves AHU 1.
AD0000 Humidifiers 15 1999 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 40.000 # Dri-Steem (model# GTS-400-CAB) is located in the North 1999 Addition at
the 3rd Floor Mechanical Room and serves the air handling unit. The unit
is not installed correctly according to previous reports. Allow to
activate/modify the installation along with commissioning. Serves AHU 2
and 3.
AD0000 Humidifiers 15 1999 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 40.000 # Dri-Steem (model# GTS-400-CAB, serial# 1063382-03-01-A) is located in
the Main Mechanical Room. The unit was not in operation at the time of
the inspection.
AD0000 Humidifiers 15 1999 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 28.000 # Dri-Steem (model# GTS-150-CAB, serial# 1063382-04-01-A) is located in
the Main Mechanical Room. This unit is suspended from the ceiling
structure. The unit was not in operation at the time of the inspection.
AD0000 Terminal Heat Transfer
Units
Unit Heaters, electric 25 2006 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.000 # Rosemex (model# H-18), 1/20 HP, 0.94 A electric suspended unit heaters
are in good condition at Athletic Centre service rooms.
$ -
AD0000 Terminal Heat Transfer
Units
Unit Heaters, hot water 25 2006 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.300 # Myson hydronic heaters are located in the stairwells. $ -
AD0000 Terminal Heat Transfer
Units
Force Flow Heaters 30 2006 20 2035 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 # Hot water force flow units, surface or recessed type, are located in the
Athletic Centre Wing.
AD0000 Terminal Heat Transfer
Units
Finned Tube Radiation 40 1994 18 2033 Good Functiona
lity
3-Not Yet
Critical
$ 2 $ 2 $ 2.000 LS 1 Hydronic baseboard heaters are installed in the Change Rooms and
Boardroom.
$ 2
AD0000 Terminal Heat Transfer
Units
Perimeter Radiators 30 1926 -60 1955 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 27.000 LS Perimeter radiators at Barbara Robson Hall are in fair condition.
Page 21 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Terminal Heat Transfer
Units
Perimeter Radiators 30 1926 -60 1955 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 18.000 LS Perimeter radiators at 5th Floor Tower area are in fair condition.
AD0000 Terminal Heat Transfer
Units
Perimeter Radiators 30 2009 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.000 LS Newer radiators are installed along a portion of the 4th Floor corridor at the
Wellness Centre.
AD0000 Terminal Heat Transfer
Units
Perimeter Radiators 30 1926 -60 1955 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 500.000 LS Older radiators are installed at the 400 Level, 300 Level, 200 Level, 100
Level and 000 Level. Allow to replace the heaters in the short term.
AD0000 Terminal Heat Transfer
Units
Radiant Ceiling Panels,
hot water
30 1999 13 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 125.000 LS Airtex Eng-Air (model(HEF-2) ceiling radiant heating panels are installed
along the perimeter exterior walls. The panels and controls are in good
condition. Allow for longer term refurbishment of the panels and
replacement of the valves.
$ -
AD0000 Terminal Heat Transfer
Units
Unit Heaters, hot water 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.000 # Engineered Air (model# H-4) hot water suspended unit heaters are in
good condition at the 1999 Mechanical Room.
$ -
AD0000 Terminal Heat Transfer
Units
Unit Heaters, hot water 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.000 # Engineered Air (model# H-4) hot water suspended unit heaters are in
good condition at the Main Mechanical Room.
$ -
AD0000 Terminal Heat Transfer
Units
Radiant Ceiling Panels,
hot water
30 1999 13 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 95.000 LS Airtex Eng-Air (model(HEF-2) ceiling radiant heating panels are installed
along the perimeter exterior walls. The panels and controls are in good
condition. Allow for longer term refurbishment of the panels and
replacement of the valves.
$ -
AD0000 Terminal Heat Transfer
Units
Force Flow Heaters 30 1999 13 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 # Cabinet force flow unit heaters are located n common areas throughout
the building.
$ -
AD0000 Terminal Heat Transfer
Units
Finned Tube Radiation 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 125.000 LS Finned tube radiation piping is installed at the exterior wall base of the
building in common areas. Sloped top enclosure and pedestal type.
AD0000 Terminal Heat Transfer
Units
Force Flow Heaters 30 1999 13 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 # Hot water force flow units, surface or recessed type, are located in the
1999 Wing.
$ -
AD0000 Terminal Heat Transfer
Units
Finned Tube Radiation 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 135.000 LS Finned tube radiation piping is installed at the exterior wall base of the
building in common areas. Sloped top enclosure and pedestal type.
AD0000 Terminal Heat Transfer
Units
Force Flow Heaters 30 1979 -7 2008 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 # Hot water force flow units, surface or recessed type, are located in the
1979 Wing.
AD0000 Terminal Heat Transfer
Units
Finned Tube Radiation 30 1979 -7 2008 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 135.000 LS Finned tube radiation piping is installed at the exterior wall base of the
building in common areas. Sloped top enclosure and pedestal type.
Approximately 48 runs. Allow for localized valve replacements in short
term.
AD0000 Terminal Heat Transfer
Units
Heating Coils 30 1979 -7 2008 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 30.000 LS Heating coils are located within the ductwork. Replace in longer term.
AD0000 Terminal Heat Transfer
Units
Perimeter Radiators 40 2004 28 2043 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 125.000 LS New radiators, valves and piping were installed in the 3rd Floor Bedrooms,
2nd Floor Corridor, 1st Floor Corridor and IT Offices.
AD0000 Terminal Heat Transfer
Units
Perimeter Radiators 40 1961 -15 2000 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 100.000 LS Older radiators in 2nd Floor Classrooms C49, C48, C47, C46 and 1st
Floor Classrooms B59, B58, B57 and B56 were refurbished in 2004.
D3060 HVAC Instrumentation
and ControlsAD0000 Energy Management and
Conservations Systems
Direct Digital Control
(DDC) Systems
15 2006 5 2020 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 95.000 LS BAS system, monitor and control panels are located at the Level 300
Mechanical Room of the 1999 Wing. Landis & Gyr (model# VE598)
flowrite valves are installed on damper controls are installed.
$ -
AD0000 Energy Management and
Conservations Systems
Direct Digital Control
(DDC) Systems
15 2006 5 2020 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 95.000 LS A web-based building automation system by Empire Controls Ltd. controls
the HVAC system at Athletic Centre. Controls are located at the
Mechanical Room. The system is in good operating condition (controls AC
units, make-up air units, exhaust fans, ventilation, heating and VAV
boxes). Digital thermostats are used for each zoned area.
$ -
AD0000 Energy Management and
Conservations Systems
Direct Digital Control
(DDC) Systems
15 1999 -2 2013 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 45.000 LS A web-based building automation system by Apogee (System 600) is
located in Mechanical Room. The system is in good operating condition
(controls AC units, make-up air units, exhaust fans, ventilation, heating
and VAV boxes). Allow for ventilation review of service rooms in short
term.
AD0000 Other HVAC
Instrumentation and
Controls
20 1999 3 2018 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 LS Landis & Gyr thermostats are installed throughout the building. $ -
D3070 Testing, Adjusting and
BalancingAD0000 Pipe Systems Testing,
Adjusting and Balancing
15 1993 -8 2007 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.000 LS Allow to provide intrusive investigations of piping systems to determine
conditions.
AD0000 Air Systems Testing,
Adjusting and Balancing
8 1993 -15 2000 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 55.000 LS Allow to re-commission the main HVAC equipment to ensure proper air
flows and balance all systems in the short term>
D3090 Other Special HVAC
Systems and
EquipmentD40 Fire Protection $ -
D4010 Sprinklers
AD0000 Wet Pipe 50 1994 28 2043 Good Building
Integrity
3-Not Yet
Critical
$ 100 $ - $ 100.000 LS 1 The building is sprinklered with a wet type system fed from the Facilities
and Services Centre. Supervisory switches are located in service rooms
within the Administration Building.
Page 22 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Wet Pipe 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 1.000 LS Allow for refurbishment of the sprinkler siamese connection in longer term. $ -
AD0000 Wet Pipe 50 2006 40 2055 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 195.000 LS Fully sprinklered facility with 8 sprinkler zones F3, Atrium, F2 Level Atrium,
F2 Level, F1 Level Atrium, F1 Level, B1 Level, B2 Level). Supervised
valves located at the Pool tunnel area. Includes 4" fire line in, butterfly
valve with tamper switch, alarm check valve, piping, heads and siamese
fire department connection at exterior wall. Serviced by M & L Fire and
Burglary Alarms Inc. 905 889-8276.
AD0000 Wet Pipe 50 2006 40 2055 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 LS PVC fire line to black steel fire line at pool tunnel area. No cost carried
within study period.
AD0000 Wet Pipe 50 1983 17 2032 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 400.000 LS Partially sprinklered facility. The Boiler Room, Basement and Boarding
Room Storage Rooms were renovated in 1983 with sprinklers. The main
fire line enters the Shop area. Main black steel fire line is heavily
corroded at entry and active water was noted. Allow for repairs and retrofit
of header, main and valves. Serviced by M-L Fire & Burglary Alarms Ltd.
905 889-8276.
$ -
AD0000 Wet Pipe 50 1999 33 2048 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 200.000 LS Fully sprinklered facility with an 8-zone wet sprinkler system. Supervised
valves are located in the Room 106 and the Carpenter's Shop. Allow for
future valve replacements at main entrances.
D4020 Standpipe
AD0000 Fire Protection
Standpipe
35 1999 18 2033 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 125.000 LS Fire hose cabinets, with 1.5" diameter fire hoses, are provided on each
floor level a the original corridors and boarding floor areas. No adverse
conditions noted and no cost carried through the study period.
$ -
AD0000 Fire Protection
Standpipe
35 1926 -55 1960 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 350.000 LS The centre and south wings should be updated with a standpipe system.
D4030 Fire Protection
SpecialtiesAD0000 Extinguishers and
Cabinets
Extinguisher and
Cabinet
25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 300.000 # Newer ABC type fire extinguishers are installed within recessed steel
cabinets throughout the building. Localized extinguishers are also
installed throughout the building. Monthly inspections by M-L Fire &
Burglary Alarms Ltd.
$ -
D4090 Other Fire Protection
SystemsAD0000 Wet Chemical Kitchen 15 1999 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 7.500 LS Wet chemical fire suppression system is located at the Kitchen ventilation
hood.
AD0000 Dedicated Suppression IT 15 1999 0 2015 Poor Building
Integrity
1-
Currently
Critical
$ 40 $ 40 $ 40.000 LS 1 Allow to add dedicated suppression system to the IT Server Room. $ 40
AD0000 Other Fire Department Access 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS The main fire access route is along the front (west side) of the building.
Access is also provided to the north elevation by the service road. The
south and east elevations are accessed by a designated paved route
along the south property edge with a private hydrant located at the
northeast corner of the Athletic Wing. No allowances are carried to revise
or alter the fire route access.
$ -
AD0000 Other Hydrants 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 12.000 LS Private fire hydrants are located along the north side of the building
towards the ravine and the northeast corner of the Athletic Centre. Public
hydrants are located along Avenue Road. Allow for longer term
refurbishment of the private hydrants.
$ -
D50 Electrical $ -
D5010 Service and
DistributionAD0000 Electrical Service Underground, 3 phase,
4 wire
35 1998 17 2032 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 500.000 LS Underground 13.8 kV electrical service is fed from Rosewell Avenue to the
Hydro Vault Room to a 4-bay , 15-KV S&C Electric switchgear unit with
600A bus .
$ -
AD0000 Electrical Service 3000 A Switchgear Unit 35 1998 17 2032 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 230.000 LS Cutler Hammer switchgear unit rated at 3000A, 347/600V, 3P, 4W located
at the Hydro Vault Room. The distribution section has breakers for the
Junior School Distribution Panel DP-6JA1, Upper School Distribution
Panel DP-6UAB, Upper School Existing Switchboard.
$ -
AD0000 Electrical Service 400 A 40 1961 -15 2000 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 35.000 LS Upper School has a 347/600-Volt, 400-A service from the Main Electrical
Vault.
AD0000 Electrical Service 1200 A 40 1979 3 2018 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 125.000 LS North Wing has a 347/600-Volt, 1200-A service from the Main Electrical
Vault.
$ -
AD0000 Electrical Service 600 A 40 2006 30 2045 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 75.000 LS Athletic Centre has a Cutler Hammer distribution panel 347/600-Volt, 600-
A, 3P, 4W service at the Mezzanine Electrical Room fed from the Main
Electrical Vault. Has digital metering and distribution cell for various
circuits.
AD0000 Secondary Transformers Low Voltage,
Distribution Type
40 1994 18 2033 Good Functiona
lity
3-Not Yet
Critical
$ 4 $ 4 $ 4.000 # 1 A 30 kVA step-up transformer (208-Volt to 600-Volt) is installed in the
Elevator Room.
$ 4
Page 23 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Secondary Transformers 40 1994 18 2033 Good Functiona
lity
3-Not Yet
Critical
$ 15 $ 15 $ 15.000 # 1 A 150 kVA transformer by Hammond, T8, is installed in the Penthouse for
distribution panel RP-PHRA.
$ 15
AD0000 Secondary Transformers Low Voltage,
Distribution Type
40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 # GE Drive Isolation Transformer is rated at 15 KVA and is located at the
Mechanical Room. For inverter system to LP-2JE1.
AD0000 Secondary Transformers Low Voltage,
Distribution Type
40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 13.000 # Cutler Hammer dry type transformer TX-2JA1, located at main Electrical
Room, is rated at 150 KVA. Fed from DP-6JA1.
AD0000 Secondary Transformers Low Voltage,
Distribution Type
40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 # TX-6AB Cutler Hammer dry type transformer, 300 KVA, 600/120/208V,
3P, 4W transformer at Boiler Room is fed from MS-6UBB.
AD0000 Secondary Transformers Low Voltage,
Distribution Type
40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 # 15 KVA Cutler Hammer transformer TX-6UB3 at 1999 Mechanical Room
is in good condition.
AD0000 Secondary Transformers Low Voltage,
Distribution Type
40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 8.500 # 75 KVA Cutler Hammer transformer TX-6UA3 at 1999 Mechanical Room
is in good condition.
AD0000 Secondary Transformers Low Voltage,
Distribution Type
40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 13.000 # Cutler Hammer TX-6UAB, 150 KVA, 600/120/208V, 3P, 4W fed from DP-
6UAB, dry type transformer at Hydro Room.
AD0000 Secondary Transformers Low Voltage,
Distribution Type
40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.000 # Cutler Hammer TX-6UBB, 75 KVA, 600/120/208V, 3P, 4W is fed from DP-
6UAB. Located at Main Electrical Room.
AD0000 Secondary Transformers Low Voltage,
Distribution Type
40 2006 30 2045 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 21.000 # 225 KVA transformer at Athletic Centre: TX-1 by Rex.
AD0000 Secondary Transformers Low Voltage,
Distribution Type
40 2006 30 2045 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 # 30 KVA transformer at Athletic Centre: TX-2 by Rex.
AD0000 Secondary Transformers Low Voltage,
Distribution Type
40 2006 30 2045 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 # 30 KVA transformer at Athletic Centre: TX-3 by Rex.
AD0000 Secondary Transformers Low Voltage,
Distribution Type
40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.500 # 45 KVA transformer at UPS at Boiler Room.
AD0000 Secondary Transformers Low Voltage,
Distribution Type
40 2006 30 2045 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 8.500 # 75 KVA JVC transformer at Boiler Room is for the Emergency Power
circuits.
AD0000 Distribution Panels 600 A 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 12.000 # Cutler Hammer panelboard Type PL4, 600-Amp, 120/208-Volt, 3P, 4W is
located in the Main Electrical Room and is in good condition.
AD0000 Distribution Panels 1200 A 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 # Cutler Hammer panelboard Type PL4, 1200-Amp, 347/600V, 3P, 4W is
located in the Main Electrical Room and is in good condition.
AD0000 Distribution Panels 800 A 40 1994 18 2033 Good Functiona
lity
3-Not Yet
Critical
$ 60 $ 60 $ 20.000 # 3 Federal Pioneer Electric 120/208-Volt distribution panels are installed in
the Telephone Room (DP-NCC) and Penthouse (Panels A, B, and RP-
PHRA).
$ 60
AD0000 Distribution Panels 800 A 40 2006 30 2045 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 16.000 # Cutler Hammer panelboard DP-BB, Type PL4, 800-Amp, 120/208-Volt,
3P, 4W is located in the Mezzanine Electrical Room and is in good
condition. Fed from FX1 at Mezzanine Electrical Room.
AD0000 Branch Circuit
Panelboards
225 A 25 1994 3 2018 Good Functiona
lity
3-Not Yet
Critical
$ 4 $ 4 $ 3.500 # 1 200-Amp, 120/240-Volt, 3 phase, 4 wire, 42 circuit panels are installed in
service rooms. Panels LP-LNA, RP-NRN, RP-NRP (2 panels), and LP-
NEB are located on the first floor adjacent to the Janitor's Room. Panels
RP-2RB (2 panels), RP-2RA, LP-2LA, and LP-2EA are located in the
second floor Utility Room. Panels LP-NBR and RP-BRA are located in the
Telephone Room. Circuits are typically labelled.
$ 4
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.500 # Cutler Hammer panel RP-2JB1, 225-Amp, 120/208-Volt, 3P, 4W, 42
circuit. It is fed from DP-2JA1 and is used for lighting, exhaust fans, etc. It
is in good condition.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.500 # Cutler Hammer panel PP-2JC2, 225-Amp, 120/208-Volt, 3P, 4W, 42
circuit. Located in Room 217 and fed from DP-2JA1. It is in good
condition.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.500 # Cutler Hammer panel PP-2JC1, 225-Amp, 120/208-Volt, 3P, 4W, 42
circuit. Located in Room 126 and fed from DP-2JA1. It is in good
condition.
$ -
Page 24 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.000 # Cutler Hammer panel PP-2JA2, 225-Amp, 120/208-Volt, 3P, 4W, 84
circuit. Located in Room 217 and fed from DP-2JA1. It is in good
condition.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.000 # Cutler Hammer panel PP-2JA1, 225-Amp, 120/208-Volt, 3P, 4W, 84
circuit. Located in Room 126 and fed from DP-2JA1. It is in good
condition.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.000 # Cutler Hammer panel LP-6JA2, 225-Amp, 347/600-Volt, 3P, 4W, 84
circuit. Located in Room 217 and fed from DP-6JA1. It is in good
condition.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.000 # Cutler Hammer panel LP-6JA1, 225-Amp, 347/600-Volt, 3P, 4W, 84
circuit. Fed from DP-6JA1. It is in good condition.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.000 # Cutler Hammer panel RP-2JB1, 225-Amp, 120/208-Volt, 3P, 4W, 84
circuit. Located in Room 129 and fed from DP-2JA1. It is in good
condition.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.000 # Cutler Hammer lighting panel LP-6JE1, 225-Amp, 347/600-Volt, 1P, 2W,
24 circuit. Located in Room 129 and fed from Inverter System. It is in good
condition.
$ -
AD0000 Safety Switches 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 1.400 # Cutler Hammer disconnects, for Transfer and Exhaust Fans and pumps,
throughout the building are in good condition. Replacement not carried
through the study period.
$ -
AD0000 Safety Switches 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 1.400 # Cutler Hammer 30-A disconnect for lift is in good condition. Replacement
not carried through the study period.
$ -
AD0000 Motor Control Centres 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 # Cutler Hammer Freedom Series 2100 motor control centre, MCC #6JA2,
located in the Mechanical Room, is rated for 347/600-Volt, 3P, 3W. It is fed
from DP-6JA1. It is in good condition. Allow for long term replacement.
$ -
AD0000 Motor Control Centres 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 # Cutler Hammer Freedom Series 2100 motor control centre, MCC #6UA3,
located in the 1999 Mechanical Room, is rated for 347/600-Volt, 3P, 3W. It
is fed from DP-6UAB. It is in good condition. Allow for long term
replacement.
$ -
AD0000 Variable Speed Drives 20 2010 14 2029 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 7.500 # Graham 1700 Series variable speed drives (model# 1703AFC25J) are
located in the Main Mechanical Room.
$ -
AD0000 Variable Speed Drives 20 2010 14 2029 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 7.500 # Guardian variable speed drives are located in the Main Mechanical Room.
Used for the air handling units.
$ -
AD0000 Transfer Switches Automatic 25 2005 14 2029 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 29.000 # 600-V, 300-A Cutler Hammer transfer switch is in good condition. $ -
AD0000 Other Contactor 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.000 LS Site lighting contractor, controlled by photo cell, is located at Room 126. $ -
AD0000 Branch Circuit
Panelboards
400A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 # Cutler Hammer panelboard, 400-Amp, 120/208-Volt, 3P, 4W is located at
Main Electrical Vault.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.000 # Cutler Hammer panelboard RP-2UAB, 225-Amp, 120/208-Volt, 3P, 4W is
located at Main Electrical Vault.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 7.000 # Cutler Hammer panelboard LP-6UAB, 225A, 347/600V, 24 circuits, fed
from DP-6UABm is located at Main Electrical Vault.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 2002 11 2026 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.500 # Siemens panel 225-Amp, 120/240-Volt, 3P, 4W, 42 circuit is for the stage
lighting. It is in good condition.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1985 -6 2009 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.500 # Federal Pioneer panel 225-Amp, 120/240-Volt, 3P, 4W, 42 circuit is for the
Laundry Room at the 3rd Floor. It is in good condition.
AD0000 Branch Circuit
Panelboards
250 A 25 2004 13 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 # Siemens panel 250-Amp, 120/240-Volt, 3P, 4W, 30 circuit is for the 3rd
Floor Offices of the 1926 Wing. It is in good condition.
$ -
AD0000 Branch Circuit
Panelboards
100 A 25 2002 11 2026 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Siemens panel 100-Amp, 120/240-Volt, 3P, 4W, 18 circuit is for the 5th
Floor Level lighting and power. It is in good condition.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 2002 11 2026 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.500 # Siemens panel 225-Amp, 120/240-Volt, 3P, 4W, 30 circuit is for the 4th
Floor Level lighting and power. It is in good condition.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 2002 11 2026 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.500 # PP-EA, Siemens panel 225-Amp, 120/240-Volt, 3P, 4W, 30 circuit is for
the Emergency Generator power, located at the Boiler Room. It is in good
condition. Includes 600V disconnect switch and splitter.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 2002 11 2026 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.500 # Siemens panel 225-Amp, 120/240-Volt, 3P, 4W, 42 circuit is for the UPS
back-up power, located at the Boiler Room.
$ -
Page 25 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Branch Circuit
Panelboards
800 A 25 2002 11 2026 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 # Siemens power panel B, 800-Amp, 120/208-Volt, 3P, 4W, 50 circuit is fed
from main distribution panel and serves the south wing pool, gymnasium,
change rooms, main school centre power risers, south wing bedrooms,
portable, Staff House, Art Room, Hub Room. Poor identification of
circuits noted.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 2002 11 2026 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.500 # Siemens power panel A, 225-Amp, 120/208-Volt, 3P, 4W, 42 circuit is fed
from main distribution panel.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 2002 11 2026 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.500 # Siemens power panel B 225-Amp, 120/208-Volt, 3P, 4W, 30 circuit is fed
from main distribution panel.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 2002 11 2026 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.500 # Siemens power panel C, 225-Amp, 120/208-Volt, 3P, 4W, 42 circuit is fed
from main distribution panel.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 2002 11 2026 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.500 # Siemens power panel D, 225-Amp, 120/208-Volt, 3P, 4W, 42 circuit is fed
from main distribution panel.
$ -
AD0000 Branch Circuit
Panelboards
100 A 25 2006 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.000 # Cutler Hammer RP-B1 power panel D, 100-Amp, 120/208-Volt, 3P, 4W, 24
circuit is fed from DP-BB. Located in Pool Mechanical Room.
$ -
AD0000 Branch Circuit
Panelboards
250 A 25 2006 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 # Cutler Hammer 250-A, PP-EA, 600V, 3P, 3W, 66 circuit for emergency
power at Mezzanine Electrical Room. Fused at 100-A. Serves
transformers and pumps.
$ -
AD0000 Branch Circuit
Panelboards
100A 25 2006 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.000 # Cutler Hammer 100-A, RP-B4, 3 P, 4W, 42 circuit at Mezzanine Electrical
Room.
$ -
AD0000 Branch Circuit
Panelboards
25 2006 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 # Cutler Hammer RP-B6, 84 circuit at Mezzanine Electrical Room serves the
main pool lighting, basement lighting, first floor lighting, mezzanine floor
lighting.
$ -
AD0000 Branch Circuit
Panelboards
100A 25 2006 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.000 # Cutler Hammer 100-A, LP-EB, 42 circuit at Mezzanine Electrical Room
serves the BAS, Data and Pool.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 2006 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Siemens power panel South Wing Level B, 225-Amp, 120/208-Volt, 3P,
4W, 30 circuit is fed from Boiler Room Mezzanine.
$ -
AD0000 Branch Circuit
Panelboards
100 A 25 2010 19 2034 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Square D power panel South Wing Level B, 100-Amp, 120/208-Volt, 3P,
4W, 30 circuit is located in the Slop Sink Room.
AD0000 Branch Circuit
Panelboards
225 A 25 2010 19 2034 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Panelboard at Room B39 is in fair condition.
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Panelboard at Room C27 is LP-6UA2 , 225A, 84 circuits, 347/600V fed
from DP-6UAB.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Panelboard at Room C27 is RP-2UA2 , 225A, 120/208V, 84 circuit fed
from DP-2UAB.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Panelboard at Room B34 is LP-6UA1, 347/600V fed from DP-6UAB. $ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Panelboard at Room B34 is RP-2UA1, 120/208V fed from DP-2UAB. $ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Panelboard at underside of service stair RP-2UB2, 120/208V fed from
SP6-UAB.
$ -
Page 26 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.500 # Panelboard at 3rd Floor Mechanical Room RP-2UA3, 120/208V, 42-circuit
is fed from TX-6UB3.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Panelboard at Theatre Sound Room RP-2UB3, 120/208V fed from SP-
6UAB.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Panelboard at 3rd Floor is for the south wing bedrooms: Siemens 225A,
120/240V, 3P, 4w fed from Boiler Room Mezzanine.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Panelboard at 2nd Floor is for the south wing Classrooms: Siemens
225A, 120/240V, 3P, 4w fed from Boiler Room Mezzanine.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Panelboard at 2nd Floor is for the south wing IT Office: Siemens 225A,
120/240V, 3P, 4w fed from Boiler Room Mezzanine.
$ -
AD0000 Branch Circuit
Panelboards
250 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Panelboard at 3rd Floor Offices: Siemens 250A, 120/208V, 3P, 4w. $ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Panelboard at B48 Office area: Siemens 225A RP-2UG2, 120/208V, 3P,
4w.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 2003 12 2027 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Panelboard at C34 Office area: Siemens 225A, 120/208V, 3P, 4w., 24-
circuit.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Panelboard at Level 100 Hall: Siemens 225A RP-2UG2, 120/240V, 3P,
4w.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Panelboard at Level 100 Hall: Siemens 225A, 120/240V, 3P, 4w, 24
circuit.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Panelboard at Level 100 Hall: Panel RB 2UJ1, 225A, 120/208V, 3P, 4w,
fed from stage circuit.
$ -
AD0000 Branch Circuit
Panelboards
225 A 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Panelboard at Garage: RP-2UH1 , 225A, 120/208V, 3P,4W, 42-circuit fed
from Boiler House Mezzanine. Complete with Tork timer for exterior
lighting.
$ -
AD0000 Safety Switches 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 # Moisture proof disconnects are installed at the Kitchen areas. $ -
AD0000 Safety Switches 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 8.000 LS Various rated disconnects at service rooms are in good condition. $ -
AD0000 Safety Switches 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 8.000 LS Various rated disconnects at service rooms are in good condition. $ -
AD0000 Safety Switches 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 8.000 LS Various rated disconnects at service rooms are in good condition. $ -
AD0000 Safety Switches 25 2002 11 2026 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 8.000 LS Various disconnects at Boiler Room are in fair-to-good condition. $ -
-2016 Building
Integrity
1-
Currently
Critical
Page 27 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Safety Switches 25 2002 11 2026 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 8.000 LS Various disconnects at North Mechanical Room Level A are in fair-to-good
condition.
$ -
AD0000 Safety Switches 25 2006 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS Various disconnects at Service Rooms including the Elevator Machine
Room, Pool Mechanical Room.
$ -
AD0000 Safety Switches 25 2006 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS Various disconnects at Service Rooms including the Elevator Machine
Room, Pool Mechanical Room.
$ -
AD0000 Other Thermography 5 1993 -18 1997 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 10.000 LS Allow for thermography scan in short term to determine condition of all
equipment. Short term replacement years may be altered.
D5020 Lighting and Branch
WiringAD0000 Interior Lighting Fluorescent Fixtures 30 1994 8 2023 Fair Functiona
lity
4-
Recomm
ended
$ 160 $ 160 $ 0.400 # 400 Fluorescent lighting is installed throughout. Lighting includes potlights and
wall mounted fixtures with compact fluorescent lamping and T8
fluorescent light fixtures. Vapour proof fixtures are installed in the Change
Rooms. Parabolic diffusers are installed in office areas.
$ 160
AD0000 Interior Lighting LED Fixtures 25 2010 19 2034 Good Functiona
lity
4-
Recomm
ended
$ 5 $ - $ 0.500 # 10 LED pot lights are installed in the Boardroom.
AD0000 Interior Lighting Fluorescent Fixtures 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.500 LS LED track lighting fixture at Open Studio is in good condition. $ -
AD0000 Interior Lighting Fluorescent Fixtures 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.750 # 1'x4', double T8 fluorescent lamped, suspended light fixtures are located
throughout the gymnasium.
$ -
AD0000 Interior Lighting Metal Halide 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.550 LS 100-W metal halide fixtures at main foyer are in good condition. $ -
AD0000 Interior Lighting Metal Halide 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.750 LS 400-W metal halide fixtures at Library are in good condition. $ -
AD0000 Interior Lighting Halogen Fixtures 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.750 LS Par halogen lamped suspended fixtures at Library are in good condition. $ -
AD0000 Interior Lighting Halogen Fixtures 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.500 LS Par halogen lamped recessed fixtures at main foyer area at Library are in
good condition.
$ -
AD0000 Interior Lighting 25 2006 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 300.000 LS Lighting fixtures for Athletic Centre are in good condition. Includes T8
fixtures in foyers and halls and F32 T6 4' strip with wire cage at Pool
tunnel area.
$ -
AD0000 Interior Lighting 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 200.000 LS Lighting fixtures for Centre Wing are in good condition. Traditional style
fixtures. Dorms use 1'x4' T8 lamped surface mounted fluorescent fixtures
$ -
AD0000 Interior Lighting 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 120.000 LS Lighting fixtures for South Wing are in good condition. Typically 2'x4'
fluorescent type fixtures, 120V, 160W, 4-lamp, T8.
$ -
AD0000 Interior Lighting 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 125.000 LS Lighting fixtures for North Wing are in good condition. Includes decorative
and specialty fixtures,
$ -
AD0000 Interior Lighting 25 2006 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 29.000 LS Lighting fixtures for the Pool are in good condition. Includes Oaktronics
metal halide and Portfolio C16032 Series hanging CFL fixtures. Includes
22 uplights, 12 wall sconces and 8 CFL type.
$ -
AD0000 Interior Lighting 25 2006 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 35.000 LS Lighting fixtures (58) for the double and single Gyms are in good condition.
The fixtures are high intensity TM9 metal halide, indirect with pulse start
lamp ballasts and 400-W lamping. In single and dual head format.
$ -
Page 28 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Interior Lighting 25 2006 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 35.000 LS Lighting fixtures (58) for the double and single Gyms are in good condition.
The fixtures are high intensity TM9 metal halide, indirect with pulse start
lamp ballasts and 400-W lamping. In single and dual head format.
$ -
AD0000 Interior Lighting 25 2006 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.000 LS Cube wall mounted T8 fluorescent fixtures are installed in the northwest
stairwell.
$ -
AD0000 Interior Lighting 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.000 LS Magnetek 400W ballasts for metal halide fixtures for Theatre work lights
are in good condition.
$ -
AD0000 Interior Lighting 25 1926 -65 1950 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 40.000 LS 6 large suspended lighting fixtures, with triple pendent fixtures, for the
Barbara Robson Assembly Hall are in good condition. The suspended
fixtures have historical significance. Replacement is not anticipated.
AD0000 Interior Lighting 25 1979 -12 2003 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.000 LS Par halogen lighting fixtures and stage lighting are in good condition.
Includes tracking and blackout curtains and wall mounted metal halide
fixtures. Barbara Robson Hall.
AD0000 Interior Lighting Light Dimming System 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.500 # Stage-Scope dimming system by Stagecraft Industries and NSI
commercial dimmer pack are located at the Gymnasium .
$ -
AD0000 Interior Lighting Light Dimming System 20 2006 10 2025 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 22.000 # Low voltage lighting programmable controllers are used for the exterior
lighting and pool lighting systems. The controllers are in good condition.
Relay panels are located in Mezzanine Electrical Room.
$ -
AD0000 Interior Lighting Light Dimming System 20 2006 10 2025 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 18.000 # Lumitrol theatre lighting dimming system (hanging cord patch panel) and
Ash-Stevenson Tec 8112 preset dimmer unit.
$ -
AD0000 Other Switches and
Receptacles
25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Decora decorative switches and standard three-prong receptacles are in
good condition. GFI receptacles are installed near sink locations as
required.
$ -
AD0000 Other Switches and
Receptacles
25 1979 -12 2003 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 LS Lighting switch panel for Assembly Hall, at Stage, is in need of updating.
AD0000 Solar Panels Rooftop Solar Panels 20 2013 17 2032 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 80.000 LS Rooftop solar panels were installed on the 1999 wing in 2013. Panels are
by Eclipsall (model# NRG60-250P) with rated STC power of 250 W.
System provides power for auxiliary panels located in the Athletic Wing
Mechanical Room. SMA Sunny Boy (model# SB600oUS-11) utility
interactive 1-phase inverter has a 6000W AC rating.
$ -
D5030 Communication and
SecurityAD0000 Detection and Fire
Alarms
25 1994 3 2018 Fair Life
Safety
4-
Recomm
ended
$ 25 $ 25 $ 25.000 LS 1 Simplex 4602 annunciator panel located at the entrance. The Simplex
4100 fire alarm control panel is located in the Security Office. Heat and
smoke detectors, alarm bells, and pull stations are located throughout.
Strobe fixtures are installed in the Change Rooms and Penthouse. Pull
stations are installed above the maximum height of 1200mm (47") for
accessibility. A Notifier annunciator panel is also located in the Security
Office and serves the six adjacent buildings.
$ 25
AD0000 Detection and Fire
Alarms
25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 118.000 LS Building annunciator and zone plan at main vestibule are in good
condition.
$ -
AD0000 Detection and Fire
Alarms
Fire Safety Plan 15 2014 13 2028 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.500 LS Upper School Fire Safety Plan is under review and editing by
Management (September 2014). Allowances are carried for updating the
plan for Fire Department approval.
$ -
AD0000 Detection and Fire
Alarms
Fire Safety Plan 15 2014 13 2028 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 LS Fire Safety Plan was reviewed at the Facility Office. The plan requires
updating.
$ -
AD0000 Security Access and
Surveillance
CCTV or Video
Surveillance Systems
15 2014 13 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 52.000 LS The existing exterior video surveillance system is being upgraded. New
cameras were installed at the South House and Junior School and Athletic
Centre main door.
$ -
AD0000 Security Access and
Surveillance
CCTV or Video
Surveillance Systems
15 2015 14 2029 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 120.000 LS The school was upgraded with new digital cameras with IP based system
and 30-day recording back-up storage.
$ -
AD0000 Security Access and
Surveillance
Electronic Access
Controls
15 2015 14 2029 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 35.000 LS EAC system added for shipping/receiving door, the IT Server Room and a
card reader at Athletic Centre-to-School and .
$ -
Page 29 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Security Access and
Surveillance
Electronic Access
Controls
15 2015 14 2029 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.500 LS EAC system added to house. $ -
AD0000 Security Access and
Surveillance
Electronic Access
Controls
15 2005 4 2019 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Keyscan Access Control Systems are installed. $ -
AD0000 Security Access and
Surveillance
Electronic Access
Controls
15 2006 5 2020 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Keyscan Access Control Systems are installed throughout the service
rooms.
$ -
AD0000 Security Access and
Surveillance
Plans 15 2015 14 2029 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 60.000 LS Business Continuity and Disaster Recovery Plan were implemented as
part of Risk Management.
$ -
AD0000 Security Access and
Surveillance
Other 15 1999 -2 2013 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 40.000 LS Intrusion detection system updated to include recessed contacts with
glass break sensors in first floor areas. Also add panic alarm buttons in
common hall areas.
AD0000 Security Access and
Surveillance
Other 15 1999 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 LS Aiphone door entry call station is installed at the Main Office.
AD0000 Sound Systems 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.000 LS Valcom ceiling speakers are in good condition. $ -
AD0000 Other Communication
and Security Systems
Emergency and Exit
Lighting
20 2010 14 2029 Good Functiona
lity
4-
Recomm
ended
$ 6 $ 6 $ 0.400 # 15 LED exit signage is installed throughout. $ 6
AD0000 Other Communication
and Security Systems
Exit Lighting 20 1975 -21 1994 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.300 # Illuminated exit signage is in fair condition. Fixtures are incandescent type.
Allow to update to LED type.
AD0000 Other Communication
and Security Systems
Exit Lighting 20 2006 10 2025 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.300 # Beghelli illuminated exit signage is in good condition. $ -
AD0000 Other Communication
and Security Systems
Emergency Lighting 20 1999 3 2018 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.350 # Plug-in, battery operated Lumacell fixtures are installed throughout the
building including the Assembly Hall.
$ -
AD0000 Other Communication
and Security Systems
Emergency Lighting 20 1999 3 2018 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.600 # Plug-in, battery operated heads are located throughout the hall with Dual
Lite battery units throughout the addition.
$ -
AD0000 Other Communication
and Security Systems
20 1999 3 2018 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 40.000 LS Communication and data wiring, hardware and racking are in good
condition. Includes APC (Smart UPS RT 3000) back-up unit.
$ -
AD0000 Other Communication
and Security Systems
35 1999 18 2033 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.000 LS Telephone backbone and wiring are in good condition. $ -
AD0000 Other Communication
and Security Systems
35 2006 25 2040 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.000 LS Telephone backbone and wiring are in good condition at Mezzanine IT
Room.
D5090 Other Electrical
SystemsAD0000 UPS 20 2009 13 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 40.000 LS Eaton Powerware UPS (model# 9355) is rated at 30 KVA. $ -
AD0000 Packaged Engine
Generator
25 2006 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 175.000 LS Packaged Generac generator (model# S686670100) is rated for 250 kVA
for the Athletic Centre. Access to the unit was not available. Allow to
include circuit for Food Service refrigeration in the immediate term.
$ -
AD0000 Packaged Engine
Generator
25 1999 8 2023 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 525.000 LS The Junior School has no emergency generator. Allow for adding an
emergency generator and updating/expanding the IT capacity.
$ -
E EQUIPMENT AND
FURNISHING
$ - $ - $ - $ 18 $ - $ - $ - $ - $ - $ 10 $ - $ - $ - $ - $ - $ - $ - $ - $ - $ -
E10 Equipment $ -
Page 30 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
E1010 Commercial
Equipment
E1090 Other Equipment
AD0000 Other 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.000 LS Ceiling mounted projectors are located in each Classroom. The Copy
Room has a Sharp copier. Items are considered operational items and
are not included.
$ -
AD0000 Exterior Furnishings 25 1974 2 2017 Fair Accessibil
ity
4-
Recomm
ended
$ 2 $ 2 $ 2.000 LS 1 No bench is provided at the main entrance, allow to provide. $ 2
E20 Furnishings $ -
E2010 Fixed Furnishings
AD0000 Fixed Casework Cabinetry 25 2006 15 2030 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 LS Built-in display cases at the Gymnasium corridor are in good condition. $ -
AD0000 Fixed Casework Cabinetry 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 12.000 LS Wood framed display cabinets at the Main Floor corridor are in good
condition.
$ -
AD0000 Fixed Casework Cabinetry 30 1994 8 2023 Fair Appearan
ce
4-
Recomm
ended
$ 10 $ 10 $ 10.000 LS 1 Laminate cabinetry is installed in the Cafeteria, Kitchenettes, and office
areas. Cabinetry is functional but dated.
$ 10
AD0000 Fixed Casework Cabinetry 30 1994 2 2017 Fair Accessibil
ity
5-Does
Not Meet
Current
Code
$ 10 $ 10 $ 10.000 LS 1 Laminate and wood framed reception desk with glazing is in fair condition
though dated. The desk is not lowered for barrier-free access as required.
Allow for short term replacement or refurbishment.
$ 10
AD0000 Window Treatment 20 1999 3 2018 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Sunproject fabric roller type blinds are installed in the Classrooms and
other support areas. All treatments are in good condition. Replacement
carried in the longer term.
$ -
AD0000 Fixed Casework Laminate Cabinetry and
Countertops
25 1994 2 2017 Fair Appearan
ce
3-Not Yet
Critical
$ 6 $ 6 $ 6.000 LS 1 Laminate countertops in the Change Rooms and Washrooms are in fair
condition with localized deterioration. The countertop in the Cafeteria is
worn. Counters are dated but otherwise functional. Repairs where
delamination is occurring are considered maintenance.
$ 6
AD0000 Fixed Casework Laminate Cabinetry and
Countertops
25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 250.000 LS Laminate wall mounted cabinetry, shelving and countertops are in good
condition.
$ -
AD0000 Fixed Casework Laminate Cabinetry and
Countertops
25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 55.000 LS Laminate wood desks and counters at Main Office are in good condition. $ -
AD0000 Fixed Casework Laminate Cabinetry and
Countertops
25 1999 8 2023 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 900.000 LS Laminate wall mounted upper/lower cabinetry and countertops are in
fair=to-good condition.
$ -
E2020 Movable Furnishings
F SPECIAL
CONSTRUCTION AND
DEMOLITION
$ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ -
F10 Special Construction $ -
F1010 Special Structures
F1020 Integrated
Construction
F1030 Special Construction
F1040 Special Facilities
F1050 Special Controls and
InstrumentationAD0000 Other Special Controls
and Instrumentation
CO Detection 12 2006 2 2017 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 7.000 LS Kidde Night Hawk plug-in smoke detectors are located at the Athletic
Centre Mechanical Room. Allow for hard wired system and detectors.
$ -
AD0000 Other Special Controls
and Instrumentation
CO Detection 12 2006 2 2017 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 10.000 LS Kidde Night Hawk plug-in smoke detectors are located at the Main Boiler
Room. Allow for hard wired system and detectors.
$ -
F20 Selective Building
Demolition
$ -
F2010 Building Elements
Demolition
F2020 Hazardous
Components
AbatementAD0000 Hazardous Substance
Report
10 1993 -13 2002 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Allow to update Asbestos Survey Plan and provide a complete Designated
Substance Report. Some older incandescent fixtures have asbestos heat
shields.
G SITEWORK $ 4 $ 5 $ - $ - $ 40 $ - $ 8,762 $ - $ 6 $ 26 $ - $ - $ - $ - $ 67,550 $ - $ - $ - $ - $ -
G10 Site Preparation $ -
Page 31 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
G1010 Site Clearing
G1020 Site Demolition and
Relocation
G1030 Earthwork
G1040 Hazardous Earth
Remediation
G20 Site Improvements $ -
G2010 Roads
AD0000 Flexible Roadway
Pavement
Asphaltic Concrete 18 1999 1 2016 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.009 sf South and east asphalt paved roadway is in fair condition. Fatigue
cracking was noted. Allow for short term repairs.
$ -
AD0000 Flexible Roadway
Pavement
Asphaltic Concrete 18 2006 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.090 sf Asphalt surfaced drop-off semi-circular drive at west main entrance is in
good condition.
$ -
AD0000 Flexible Roadway
Pavement
Asphaltic Concrete 18 1999 1 2016 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.090 sf West drive is in fair condition. Allow for replacement in the mid-term. $ -
G2020 Parking Lots
AD0000 Flexible Parking Lot
Pavement
Asphaltic Concrete 18 1994 5 2020 Fair Functiona
lity
3-Not Yet
Critical
$ 5 $ 8,712 $ 8,717 $ 0.090 sf 96800 North parking lot and entrances drives from Old Finch Avenue are paved
with asphaltic concrete. The surface is in fair condition. Unit pavers are
installed in front of the main entrance. Localized settlement and fatigue
cracking was noted. Allow for short term repairs and then replacement.
$ 5 $ 8,712
AD0000 Unit Pavers Parking Lot 35 1999 18 2033 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.013 sf Permeable unit pavers at the Junior School diagonal parking stalls are in
fair condition. Allow for short term repairs and long term replacement.
$ -
AD0000 Unit Pavers Drive 35 1999 18 2033 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.013 sf Unit pavers are installed at the main drive area. The pavers are settled
and rutted. Allow for minor repairs in short term.
$ -
AD0000 Unit Pavers 40 1999 23 2038 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.013 sf Permeable unit pavers along the west drive are in fair condition. Allow for
long term replacement.
AD0000 Flexible Parking Lot
Pavement
Asphaltic Concrete 25 1978 -13 2002 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.009 sf Asphalt parking lot at west tier of main parking lot is in fair condition with
moderate longitudinal cracking, fatigue cracking, and settlement at the
catch basins. Settlement at the drive between the parking lot and main
entrance circle was also noted. Allow for short term repairs and
replacement in the longer term.
AD0000 Flexible Parking Lot
Pavement
Asphaltic Concrete 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.011 sf Asphalt parking lot at east tier of main parking lot, drive aisle and service
area are in good condition. Combination of heavy and light duty
pavements. Allow for minor crack repairs in short term.
$ -
AD0000 Flexible Parking Lot
Pavement
Asphaltic Concrete 18 1999 1 2016 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.009 sf Asphalt turn circle at main entrance is in good condition. $ -
AD0000 Flexible Parking Lot
Pavement
Concrete 25 1999 8 2023 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.025 sf Poured concrete at northwest garbage area is in fair condition with minor
staining. Allow for long term replacement.
$ -
AD0000 Parking Lot Curbs and
Gutters
Poured Concrete 30 1999 5 2020 Fair Functiona
lity
3-Not Yet
Critical
$ 50 $ 50 $ 0.025 lf 2000 Parking lot is partially outlined by poured concrete curbs. Curbs are in fair
condition overall with minor wear and cracking throughout. Allow for
replacement with asphalt paving.
$ 50
AD0000 Parking Lot Curbs and
Gutters
Poured Concrete 30 1999 13 2028 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.025 lf Poured concrete curbs at the Upper School parking lot and drives are in
fair condition. Localized cracking was noted. Allow for short term repairs
and long term replacement. Curbs are not installed along the sides of the
parking lots and drives that are adjacent to the ravine.
$ -
G2030 Pedestrian Paving
AD0000 Pedestrian Unit Pavers Brick Pavers 30 1994 8 2023 Good Functiona
lity
3-Not Yet
Critical
$ 4 $ 26 $ 30 $ 0.013 sf 2000 Unit pavers are installed on the north elevation at the entrances.
Settlement was noted at curb edges, creating a trip hazard. Re-levelling as
needed is considered maintenance.
$ 4 $ 26
Page 32 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Pedestrian Unit Pavers Brick Pavers 30 2009 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.025 sf Stone sidewalk at the main entrance is in fair condition. Settlement at the
curb has created a trip edge. Allow for immediate repairs. Stone walkways
are also installed at the Athletic Centre entrance.
AD0000 Rigid Pedestrian
Pavement
Poured Concrete 30 1999 13 2028 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.020 sf Poured concrete sidewalk at the main entrance circle is in fair condition.
Allow for long term repairs.
$ -
AD0000 Rigid Pedestrian
Pavement
Poured Concrete 30 1999 13 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.016 sf Poured concrete sidewalk at the parking lot and main entrance to the
Junior School is in good condition. A newer section at the main entrance
drive was noted. Allow for long term replacement.
$ -
AD0000 Rigid Pedestrian
Pavement
Poured Concrete with
Wood
10 1999 -7 2008 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.010 sf Poured concrete sidewalk with wood slat inlay sections at the rear patio
areas of the Junior School is in fair condition with localized damage and
tripping hazards. Includes precast concrete patio slabs at rear walk also.
Allow for repairs every 10 years.
AD0000 Rigid Pedestrian
Pavement
Asphaltic Concrete 20 1961 -35 1980 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.007 sf Older asphalt path at west side of main building is in poor condition with
cracking and significant cross slope.
AD0000 Rigid Pedestrian
Pavement
Asphaltic Concrete 20 1999 3 2018 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.007 sf Asphalt walkways on the south and west sides of the Upper School and
Junior School are in fair condition. Minor fatigue cracking was noted,
particularly along the edges. Allow for replacement in the mid-term.
$ -
AD0000 Loose Surfacing Screenings 12 1999 -5 2010 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.000 LS Screening surfaced pathways between Upper School and Junior School
are in good condition. Allow for resurfacing and top up only.
AD0000 Paving Stone 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.500 LS Flagstone inlay at main entrance of school and stair landings is in good
condition. Allow for long term replacement/modifications.
$ -
AD0000 Exterior Steps and
Ramps
Stone 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.000 LS Flagstone stair at west elevation of main building is in good condition.
Allow for long term replacement/modifications.
$ -
AD0000 Exterior Steps and
Ramps
Poured Concrete 30 1980 -6 2009 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 10.000 LS Concrete stairs at walkway under main entrance are in fair condition with
minor wear. Allow for long term repairs/modifications.
AD0000 Exterior Steps and
Ramps
Poured Concrete 30 1990 4 2019 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 10.000 LS Concrete stairs to lower level at service wing are in good condition. Exit
19.
$ -
AD0000 Exterior Steps and
Ramps
Steel 30 1980 -6 2009 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 12.000 LS Steel staircase at north quad area is in fair condition with corrosion.
Refurbish in longer term.
AD0000 Exterior Steps and
Ramps
Concrete Unit Pavers 30 1999 13 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 LS The main entrance stairs are in good condition with no damage. $ -
AD0000 Exterior Steps and
Ramps
Unit Pavers 30 1999 13 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 7.000 LS Unit paver stairs at west side of Main Building to Avenue Road are in good
condition.
$ -
AD0000 Exterior Steps and
Ramps
Unit Pavers 30 1999 13 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.000 LS Unit paver stairs at south stair to play field, with wood risers, are in good
condition. Minor settlement considered maintenance.
$ -
AD0000 Exterior Steps and
Ramps
Poured Concrete 30 2006 20 2035 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 75.000 LS Concrete stairs and ramp to the Athletic Centre entrances are in good
condition. Minor cracking and nosing deterioration was noted on the south
stair. Allow for short term repairs at the south stair and long term
modifications. Includes steel railings and guards.
AD0000 Exterior Steps and
Ramps
Poured Concrete 30 1999 13 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 12.000 LS Concrete exterior stair is in good condition. $ -
Page 33 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Pedestrian Bridges 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 125.000 LS The prefabricated steel bridge, concrete abutments and metal deck cover
at the ravine are in good condition. Allow to refurbish in mid-term.
G2040 Site Development
AD0000 Street Furnishings Miscellaneous 18 1999 1 2016 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.000 LS Steel benches at main entrance, wood benches at west elevation along
with PVC receptacles.
$ -
AD0000 Retaining Walls Poured Concrete 35 1999 18 2033 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS Poured concrete retaining/seating wall at north quad is in good condition.
No allowances carried through the study period.
$ -
AD0000 Retaining Walls Precast Concrete Unit 35 1994 13 2028 Good Building
Integrity
4-
Recomm
ended
$ 67,500 $ 67,500 $ 135.000 lf 500 Precast retaining wall with centrally located stair divides the upper and
lower parking areas and at the Site Control entrance. The wall is in good
condition. Past repairs were noted to nosings on the stair.
$ 67,500
AD0000 Other Playground 15 2000 -1 2014 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 19.000 LS Henderson prefabricated PVC (model# 2262) and prefinished steel
playground equipment/apparatus is in good condition.
$ -
AD0000 Other Shed 15 2009 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.000 LS Prefabricated wood shed at Service area is in good condition. $ -
AD0000 Other Shed 15 2000 -1 2014 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.000 LS Prefabricated wood shed at Tennis Court area is in good condition. $ -
AD0000 Other Playground 15 1999 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 19.000 LS Prefabricated PVC and prefinished steel playground equipment/apparatus
is in fair condition.
AD0000 Other Playground Surfacing 15 1999 -2 2013 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 LS Rubberized surfacing is in fair condition with localized damage. Replace
with playground apparatus.
AD0000 Other Sport Apparatus 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.500 LS Two tubular steel framed soccer nets are located at the north field. $ -
AD0000 Other Sport Apparatus 25 2004 13 2028 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 10.000 LS Two tubular steel framed soccer nets are located at the east field. Netted
back stops are also provided.
$ -
AD0000 Fencing Chain Link 25 1990 -1 2014 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.045 lf Chain link fencing at the south tennis courts in poor condition. Corrosion
was noted and posts are unstable. Allow for short term replacement.
$ -
AD0000 Fencing Chain Link 25 1961 -30 1985 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.025 lf Chain link fencing at property line is in fair condition with damaged
sections.
AD0000 Fencing Ornamental 25 2006 15 2030 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.040 lf Metal picket fence along west lot line is in good condition overall. Newer
sections were noted. Allow for long term replacement.
$ -
AD0000 Fencing Ornamental 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.040 lf Prefinished metal picket fence along playground area is in good condition
overall with minor corrosion. Allow for long term replacement.
$ -
AD0000 Fencing Chain Link 25 1979 -12 2003 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.028 lf Older 6' high chain link fencing along north lot line is in fair condition.
AD0000 Signs General Signage 20 2013 17 2032 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 8.000 LS Metal framed, core board site signage on Avenue Road is in good
condition. Allow for replacement in the mid-term. Also includes second
directional signage board.
$ -
Page 34 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Signs General Signage 20 2013 17 2032 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.000 LS Metal framed scoreboard site signage on Rosewell Avenue is in good
condition. Allow for replacement in the longer term.
$ -
AD0000 Other Guards and Handrails 35 1994 13 2028 Good Functiona
lity
4-
Recomm
ended
$ 50 $ 50 $ 0.100 lf 500 Galvanized steel guards and handrails are installed at the retaining wall
and stair.
$ 50
AD0000 Other Guards and Handrails 35 1926 -55 1960 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 10.000 LS No handrails or guards are installed on concrete stairs under the main
entrance. Allow for immediate installation.
AD0000 Other Guards and Handrails 35 2006 25 2040 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS Galvanized steel guard at stair to staff room and at Athletic Centre ramps
and stairs are in good condition. Allow for long term replacement.
AD0000 Other Guards and Handrails 35 1999 18 2033 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 5.000 LS Galvanized steel handrails at the west stair at the Junior School are in
good condition. Allow for long term replacement.
$ -
AD0000 Other Guards and Handrails 30 1999 13 1 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.000 LS The stainless steel tubular handrails at main west entrance do not extend
beyond the first riser as per standard practice. Replacement is carried in
short term to correct issue.
$ -
AD0000 Other Out Building 20 2005 9 2024 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 2.500 LS Small PVC storage shed at Junior School is in good condition. $ -
AD0000 Other Out Building 25 2014 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.000 LS A prefabricated shed by NRB Inc. is located on the east elevation. The
shed is wood framed with metal siding, two metal doors, and a sloped
roof. The shed is not heated. A 125-Amp, 120/240-Volt, 20 circuit panel by
Eaton is installed. The panel is fed from Panel B in the Boiler Room. The
interior is illuminated by a compact fluorescent light fixture. A GFI
receptacle is located on the exterior. The shed is vented. Allow for long
AD0000 Other Out Building 30 2012 26 2041 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 10.000 LS The Arts Portable is a prefabricated structure with wood framing
(presumed), metal siding, aluminum framed, double glazed windows,
aluminum framed door with double glazing by Windspec, and a metal door
with glazing. Interior finishes consist of vinyl sheet flooring, gypsum wall
board, and lay-in ceiling tiles. A 125-Amp, 120/240-Volt, 20 circuit panel by
Eaton and fluorescent light fixtures are installed. Soffit mounted fixtures
are installed at the exterior. Pull stations, alarm bell, and smoke detector
are installed. Emergency light fixtures, exit signage, and panic bar door
hardware are not installed. The Portable is heated with a packaged unit
complete with Change Air digital thermostat. Standard diffusers are
installed at the ceiling. The building is accessed by two wood stairs. Minor
damage was noted to the metal siding due to heaving of the tennis court
surface. Also has a green roof assembly.
AD0000 Other Covered Canopies 18 2010 12 2027 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 4.000 LS Cloth covered, metal framed, canopies are in good condition near the Art
House.
$ -
AD0000 Deck/Gazebo 18 2008 10 2025 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 9.500 LS Wood framed gazebo with asphalt shingles, stone column bases, and unit
pavers is in good condition. Allow for long term refurbishment.
$ -
AD0000 Drinking Fountain 20 2008 12 2027 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 3.500 LS Stone framed drinking fountain is in good condition. $ -
G2050 Landscaping
AD0000 Irrigation 20 1999 3 2018 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Irrigation system (Rainbird ESP-12-LX Plus control) with Watts backflow
preventer is in good condition. Operation not verified. Allow for complete
system check with mapping and miscellaneous repairs in the short term.
$ -
AD0000 Irrigation 20 2006 10 2025 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Irrigation system (Hunter SRC Plus control) with Wilkins backflow
preventer is in good condition at pool tunnel. Operation not verified. Allow
for complete system check with mapping and miscellaneous repairs in the
short term.
$ -
AD0000 Lawns and Grasses 20 1975 -21 1994 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.002 sf Sodded areas of west sports field are in good condition with localized
wear. No allowances carried.
AD0000 Lawns and Grasses 20 1975 -21 1994 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.002 sf Sodded areas of east sports field are in good condition with localized
wear. No allowances carried.
Page 35 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Trees, Plants and
Ground Cover
40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS Consists of both mature coniferous trees and newer deciduous and
planting materials. The soft landscaping is in good condition overall. No
allowances carried over the study term.
AD0000 Trees, Plants and
Ground Cover
40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS Hiking trails located throughout the grounds are in good condition. No
future allowances carried.
AD0000 Trees, Plants and
Ground Cover
40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS The north soccer playfield is sodded and in good condition. No future
allowances carried.
AD0000 Trees, Plants and
Ground Cover
50 1970 4 2019 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Consists of both mature coniferous trees and newer deciduous and
planting materials. The soft landscaping is in good condition overall. No
significant allowances carried.
$ -
AD0000 Trees, Plants and
Ground Cover
50 1970 4 2019 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Consists of both mature coniferous trees and newer deciduous and
planting materials. The soft landscaping is in good condition overall. No
significant allowances carried.
$ -
AD0000 Trees, Plants and
Ground Cover
50 1926 -40 1975 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Consists of both mature coniferous and deciduous trees along the ravine.
No allowances carried.
AD0000 Other Learning Playspace 25 2013 22 2037 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 350.000 LS Learning playspace facility added to the Junior School.
G30 Civil and Mechanical
Utilities
$ -
G3010 Water Supply
AD0000 Site Domestic Water
Distribution
40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 12.000 LS A separate water service, from Rosewell Avenue 16" diameter water main,
enters the northeast corner of the building. System is in good condition
based on operation. Allow for longer term repairs.
AD0000 Fire Service 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 8.000 LS A separate fire line, from Rosewell Avenue 16" diameter water main,
enters the northeast corner of the building. System is in good condition
based on operation. Allow for longer term repairs.
G3020 Sanitary Sewer
AD0000 Sewage Collection 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 22.000 LS Sanitary from the Upper School Addition (1999) exits the west side of the
building and is connected to the Avenue Road main sewer line. No
reported issues with the sanitary system.
AD0000 Sewage Collection 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 15.000 LS Sanitary from the Junior School (1999) exits the north side of the building
and is connected to the Rosewell Avenue main sewer line. No reported
issues with the sanitary system.
G3030 Storm Sewer
AD0000 Storm Water Collection 40 1999 23 2038 Good Functiona
lity
3-Not Yet
Critical
$ 75 $ - $ 75.000 LS 1 Parking lot is drained to convention catchbasins.
AD0000 Storm Water Collection 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 100.000 LS Storm distribution piping to 10 catch basins, complete with manholes,
located at north parking areas. Collection is discharged to the north
embankment headwall. Stormceptor (STC 1000) is installed to remove
free oil and suspended solids. The foundation weeping tile are shown to
be connected to the storm system. System is in good operating order with
no issues reported. Allow for longer term repairs only.
AD0000 Storm Water Collection Headwall 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.000 LS Concrete headwall and steel grate at south embankment headwall is in
good condition.
AD0000 Storm Water Collection Headwall 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 6.000 LS Concrete headwall and steel grate at north embankment headwall is in
good condition.
AD0000 Manhole and Catch
Basins
40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 LS Manhole and catch basin installations are performing as intended
throughout the site. No allowances made through the study period.
Cleaning of basins is considered an operational item.
AD0000 Manhole and Catch
Basins
40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 LS Manhole and catch basin installations are performing as intended
throughout the site. No allowances made through the study period.
Cleaning of basins is considered an operational item.
G3040 Heating Distribution
G3050 Cooling Distribution
G3060 Fuel Distribution
AD0000 Gas Natural Gas 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 8.000 LS Incoming gas main from Rosewell Avenue is connected to the Roots
digital main meter and Fisher regulator at the northeast corner of the
building. Exterior service is considered the responsibility of the local utility.
No allowances carried.
Page 36 of 37
Asset ID Element ID Life
Expect.
Year
Installed
Remain.
Life
Replace.
Year
Condition Deficiency
Category
Priority Repair
in ,000's
Replace
in ,000's
Total
in ,000's
Unit Cost
in 000'
Unit Quantity Photo Notes 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034
ALL COSTS IN 000' (2015) DOLLARS
AD0000 Gas Natural Gas 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 8.000 LS There is a newer gas service from Avenue Road that is connected to the
east elevation of the Service Wing complete with Roots 12000 CFH meter
and Fisher regulator. The original gas service at this location is continued
to the 900 CFH Pool meter. No allowances carried.
AD0000 Gas Natural Gas 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 8.000 LS 900 CFH Pool Mini-Max meter and Fisher regulator. No allowances
carried.
AD0000 Gas Natural Gas 40 1999 23 2038 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 8.000 LS Mercury meter and Fisher regulator at Kitchen area is in good condition.
No allowances carried.
G3090 Other Site Mechanical
UtilitiesAD0000 TV Inspection of Sewer
Pipelines
30 1979 -7 2008 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 25.000 LS Allow for the full assessment of the sanitary and storm systems with CCTV
and intrusive means in the short term. Include for mapping piping
locations and directions.
G40 Electrical Utilities $ -
G4010 Electrical Distribution
AD0000 Power Distribution Lines 50 1990 24 2039 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 50.000 LS Power distribution cabling below grade is functioning as intended based
on usage.
AD0000 Power Distribution Lines 50 1999 33 2048 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 20.000 LS Power distribution cabling below grade is functioning as intended based
on usage. No allowances carried through the study period.
G4020 Site Lighting
AD0000 Building Illumination Metal Halide 20 1991 7 2022 Fair Functiona
lity
3-Not Yet
Critical
$ 6 $ 6 $ 1.500 # 4 Wall mounted downcast light fixtures are installed on the north elevation. $ 6
AD0000 Building Illumination Metal Halide 20 1991 -5 2010 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.300 # Various wallpacks are installed throughout the exterior. Typically metal
halide, 150W type.
AD0000 Building Illumination Metal Halide 20 2006 10 2025 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.000 # Metal halide wallpack fixtures are in good condition. $ -
AD0000 Building Illumination Metal Halide 20 2006 10 2025 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.002 LS Metal halide recessed wall lighting at exterior stair locations are in good
condition.
$ -
AD0000 Other Site Lighting parking lot standards 25 1994 3 2018 Fair Functiona
lity
4-
Recomm
ended
$ 40 $ 40 $ 5.000 # 8 Parking lot is illuminate by 20' high steel light standards with single and
double fixtures.
$ 40
AD0000 Other Site Lighting parking lot standard and
400W MH luminaire
25 1999 8 2023 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.005 # Steel light standards by Norco with single light fixtures are installed
throughout the parking lots and site. Allow for long term replacement.
Cleaning and refurbishment is an Operating item.
$ -
AD0000 Other Site Lighting 25 1999 8 2023 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.013 LS Allow for a lighting study and retrofit to LED type in short term. $ -
AD0000 Other Site Lighting 25 1999 8 2023 Fair Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.022 LS Allow for a lighting study and retrofit to LED type in short term. $ -
AD0000 Other Site Lighting 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.000 # Exterior soffit lighting is in good condition. $ -
AD0000 Other Site Lighting 25 1999 8 2023 Good Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.000 # Exterior wall mounted lighting is in good condition. $ -
G4030 Site Communication
and Security
G4090 Other Site Electrical
UtilitiesAD0000 Cabling 12 1991 -13 2002 Poor Building
Integrity
1-
Currently
Critical
$ - $ - $ 0.001 LS Allow to reattach cable box cover and provide proper cabling distribution
feeds at 1961 flat roof to 1926 building.
G90 Other Site
Construction
G9010 Service Tunnels
G9090 Other Site Systems
Total $ 4 $ 51 $ 31 $ 53 $ 473 $ - $ 8,780 $ - $ 6 $ 409 $ - $ 50 $ - $ - $ 67,713 $ 14 $ - $ - $ - $ 776