REOTEMP INSTRUMENT CORPORATIONTelephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com
Established in 1965 and locatedin San Diego, California,REOTEMP Instrument Corpora-tion is recognized as a leadingmanufacturer of pressure and temperatureinstrumentation. REOTEMP provides bimetalthermometers, pressure gauges, diaphragmseals and related accessories to a variety ofprocess markets worldwide. Recognized forexceptional customer service, on-time deliveriesand innovative engineering services,REOTEMP is an ISO 9002 certified manufac-turer. We are dedicated to continuous improve-ment, on-time deliveries, high quality products,and exceptional customer satisfaction.
Waste WaterCompostMilitaryDairyPower GenerationRefrigerationAnd More!
Table of Contents
Bimetal ThermometersGeneral Bimetal Specifications Page 33”, 4” & 5” Back Connection Page 43”, 4” & 5” All-Angle Connection Page 53”, 4” & 5” Bottom Connection Page 6Heavy-Duty Navy Thermometer Page 7Dual Mode Thermometer (DMT) Page 8-9OEM Thermometers Page 10Laboratory Thermometers Page 11Compost Thermometers Page 11Sanitary Bimetal Thermometer Page 12Bimetal Thermometer Accessoriesand Ranges Page 13
ThermowellsThreaded Type (1/4” elements) Page 14
(3/8” elements) Page 24Sanitary Type Page 14Flanged Type Page 15
Filled System ThermometersIndustrial Glass Thermometer Page 16Vapor Actuated
Remote Thermometers Page 17-19
Gas Actuated Remote ThermometersBourdon Tube Type Page 21-24Direct-Drive Type Page 25-27
Digital Thermometers Page 28
RTD’s & Thermocouples Page 29-32
Sanitary RTD’s Page 33-34
Surface Thermometers Page 35
Pocket Thermometers Page 35
Warranty Back Page
Markets Served
R E G I S T E R E DR E G I S T E R E D
Oil, Gas & PetrochemicalPharmaceuticalFood & BeveragePaper & PulpMiningUtilitiesMarine
3
Specifications – Bimetal Dial ThermometersDial Sizes: 1 1/8”, 1 3/4” 2 3/8”, 3” 4” 5”Stem Length: Between 2” and 80”Stem Diameters: 1/4” (standard),also available 5/16”, 3/8”.Heads, bezels, mounting bushing, stems:All Models 300 series SSOperating Conditions: The temperature of thehead should not be allowed to exceed 200° F (150°F if silicone filled). Stems should not be exposed tocontinuous temperatures exceeding 50% over-range, or 800° F.Hermetic seal: All 3”, 4”, and 5” models (exceptDM4) are hermetically sealed per ASME B40.3.Pointed Stems: Optional on all models. Excellentfor probing asphalt, compost, soil, frozen foods orother semi-solid materials.Dials: Anodized aluminum. Black marks and num-bers with satin matte finish background.
Crystals: Optically clear strong glass.Optional: Unbreakable clear plastic: all models (Notrecommended for ranges over 500° F).Optional: “Shatterproof” tempered glass (3”, 4”, and5” models).Accuracy: All Models are guaranteed accurate towithin plus or minus 1% of the full scale (Grade Aper ASME B40.3). Temperature readings arestabilized within 40 seconds.Immersion: For correct temperature measurement,the stem of all Models in all ranges must be im-mersed 2 inches in liquid, and 4 inches in gas exceptfor 0 to 100° F, 25 to 125° F, and 0 to 50° C whichrequire 3 1/2 inches in liquid and 5 inches in gas.Mounting Connections: 1/2” NPT (std. on 3”, 4”,5” models), 1/8” NPT, 1/4” NPT, 3/8” NPT, 3/4” NPT,3/8”-24” NF, Plain or Reset Bushing, 1/2” NPTUnion, 1/2” BSPT, BSPP Adapters.
ThermowellsThermowells should be used whenever the stem or bulb would be exposed to pressure, corrosion, orshear forces. Thermowells also make it possible to remove the thermometer without losing pressure orcontents. (See pages 14-15 for more details)
O.E.M. ApplicationsIf you are an Original Equipment Manufacturer and plan to incorporate the REOTEMP Thermometer in yourfinished product for resale, special ranges or special dials can be made to suit your particular requirements.Such specials can bear your own company name and/or trademark on the dial. The quality, appearance,and performance of a REOTEMP Thermometer will complement and enhance your equipment.
SpecificationsBimetal Thermometers
R E G I S T E R E DR E G I S T E R E D
4
AA =
BB =
CC =
RR =
SS =
CN =
025 =
040 =
060 =
090 =
120 =
150 =
180 =
240 =
300 =
360 =
1 =
4 =
5 =
X =
B =
C =
L =
M =
F23F55*F43F47F63F67F81F85
C23C55*C43C47C59C67C81C85
PS =
SF =
SS =
F3 =
PC =
PY =
TG =
MM =
Industrial 3”, 4”, 5” DialBack Connected(Angle Form)
REOTEMP INSTRUMENT CORPORATIONTelephone: (800) 648-7737 FAX (858) 784-0720 · [email protected] · www.reotemp.com
Bimetal Thermometers
REOTEMP Angle Form thermometers are ideal forlocal, eye-level temperature readings in mostprocess applications.
D23D55*D43D47D63D67D81D85
&&&&&&&&
Standard Features
• All Stainless Steel Construction• Hermetically Sealed (ASME B40.3)• Accurate to 1% of Full Scale• Standard External Reset
• Silicone Fillable for Vibration
AA 060 1 F43 SF
-Intermediatelengths available
up to 80”
-Specify length ininches + tenths
For more information onSanitary Thermometers
see page 12
How to Order
Model A 2.5" 1/2" NPT (std.) Pointed Stem(3" dial, reset)
4" 1/4" NPT Silicone Fill Model B (max temp 550°F)(5" dial, reset) 6" 3/4" NPT adapter
316 SS StemModel C 9" Plain Hex Bushing(4" dial, reset) (no threads) 3/8" dia. Stem
12"1/2" BSPT Acrylic Window
Model R 15"(3" dial, no reset) Polycarbonate
18" 1-1/2" Tri-Clamp WindowModel S (5" dial, no reset) 24" 2" Tri-Clamp Tempered Glass
WindowModel CN 30" 3/4" Tri-Clamp(4" dial, no reset) Max/Min Pointer
36" -40 TO 160°F -40 TO 70°C 25 TO 125°F 0 TO 50°C 0 TO 200°F 0 TO 100°C 0 TO 250°F -20 TO 120°C 50 TO 300°F 10 TO 150°C 50 TO 500°F 0 TO 250°C150 TO 750°F 0 TO 400°C
200 TO 1000°F 100 TO 500°C*-Not available in 2.5" stem.*-Other sizes available
0 TO 150°C 0 TO 250°C
-40 TO 70°C
0 TO 400°C 100 TO 500°C
OptionsTemperature RangesSee pg.13 for a full list.
Fahrenheit Ranges-40 TO 160°F
Sanitary*
Dual F/C Ranges
0 TO 250°F 50 TO 300°F 50 TO 500°F150 TO 750°F
200 TO 1000°FCelsius Ranges
0 TO 50°C 0 TO 100°C
For Thermowellssee pg. 14
Models StemLength
Standard Models
-20 TO 120°C
Standard Threaded*
Connection
25 TO 125°F 0 TO 200°F
Non-Reset Models
5
Industrial 3”, 4”, 5” DialAdjustable Angle Bimetal Thermometers
REOTEMP All-Angle thermom-eter allows for easy temperaturemonitoring from any position.
Standard Features
• Complete 180° Adjustability• All Stainless Steel Construction• Hermetically Sealed (ASME B40.3)• Accurate to 1% of Full Scale• Standard External Reset• Silicone Fillable for Vibration• 360° Case Rotation
LL =
MM =
JJ =
025 =
040 =
060 =
090 =
120 =
150 =
180 =
240 =
300 =
360 =
1 =
5 =
U =
C =
L =
M =
F23F55*F43F47F63F67F81F85
C23C55*C43C47C59C67C81C85
PS =
SF =
SS =
F3 =
PC =
PY =
TG =
MM =D23D55*D43D47D63D67D81D85
&&&&&&&&
-Intermediatelengths available
up to 80”
-Specify length ininches + tenths
LL 060 1 F43 SF
For more information onSanitary Thermometers see
page 12
How to Order
Model L 2.5" 1/2" NPT (std.) Pointed Stem(3" dial, reset)
4" 3/4" NPT adapter Silicone Fill Model M (max temp 550°F)(4" dial, reset) 6" 1/2" NPT Union
316 SS StemModel J 9"(5" dial, reset) 1-1/2" Tri-Clamp 3/8" dia. Stem
12"2" Tri-Clamp Acrylic Window
15"3/4" Tri-Clamp Polycarbonate
18" Window
24" Tempered Glass Window
30"Max/Min Pointer
36" -40 TO 160°F -40 TO 70°C 25 TO 125°F 0 TO 50°C 0 TO 200°F 0 TO 100°C 0 TO 250°F -20 TO 120°C 50 TO 300°F 10 TO 150°C 50 TO 500°F 0 TO 250°C150 TO 750°F 0 TO 400°C
200 TO 1000°F 100 TO 500°C
Dual F/C Ranges
Fahrenheit Ranges
Temperature RangesSee pg.13 for a full list.
Options
100 TO 500°C 0 TO 400°C 0 TO 250°C 0 TO 150°C -20 TO 120°C
Standard Models
StemLengthModels
0 TO 100°C 0 TO 50°C
0 TO 250°F
-40 TO 160°F
50 TO 300°F
Connection
Standard Threaded
Sanitary*
0 TO 200°F 25 TO 125°F
-40 TO 70°CCelsius Ranges
200 TO 1000°F150 TO 750°F 50 TO 500°F
For Thermowellssee pg. 14
*-Other sizes available *-Not available in 2.5" stem.
R E G I S T E R E DR E G I S T E R E D
6
REOTEMP INSTRUMENT CORPORATIONTelephone: (800) 648-7737 FAX (858) 784-0720 · [email protected] · www.reotemp.com
Industrial 3”, 4”, 5” Dial Bottom Connected(Straight Form)
Bimetal Thermometers
XR =
YY =
VR =
XX =
YN =
VV =
025 =
040 =
060 =
090 =
120 =
150 =
180 =
240 =
300 =
360 =
1 =
4 =
5 =
C =
L =
M =
F23F55*F43F47F63F67F81F85
C23C55*C43C47C59C67C81C85
PS =
SF =
SS =
F3 =
PC =
PY =
TG =
MM =
99 =
33 =
12 =
D23D55*D43D47D63D67D81D85
XR 060 1 F43 SF
REOTEMPStraight Formthermometersare ideal forside and elevated installationson tops or sides of tanks orpipes.
Standard Features
• Bottom, Top, Right or Left Side Mounting• All Stainless Steel Construction• Hermetically Sealed (ASME B40.3)• Accurate to 1% of Full Scale• Standard External Reset• Silicone Fillable for Vibration(Standard)
&&&&&&&&
For more information onSanitary Thermometers
see page 12
-Intermediatelengths available
up to 80”
-Specify length ininches + tenths
How to Order
Model XR 2.5" 1/2" NPT (std.) Pointed Stem(3" dial, reset)
4" 1/4" NPT Silicone Fill Model Y (max temp 550°F)(4" dial, reset) 6" 3/4" NPT adapter
316 SS StemModel VR 9"(5" dial, reset) 1-1/2" Tri-Clamp 3/8" dia. Stem
12"2" Tri-Clamp Acrylic Window
Model X 15"(3" dial, no reset) 3/4" Tri-Clamp Polycarbonate
18" WindowModel YN (4" dial, no reset) 24" Tempered Glass
WindowModel V 30"(5" dial, no reset) Max/Min Pointer
36" -40 TO 160°F -40 TO 70°C 25 TO 125°F 0 TO 50°C 9 O'Clock Stem 0 TO 200°F 0 TO 100°C (left side) 0 TO 250°F -20 TO 120°C 50 TO 300°F 10 TO 150°C 3 O'Clock Stem 50 TO 500°F 0 TO 250°C (right side)150 TO 750°F 0 TO 400°C
200 TO 1000°F 100 TO 500°C 12 O'Clock Stem(top mount)
Models StemLength
Standard Models
-20 TO 120°C
Standard Threaded*
Connection
25 TO 125°F 0 TO 200°F
Non-Reset Models
Sanitary*
Dual F/C Ranges
0 TO 250°F 50 TO 300°F 50 TO 500°F150 TO 750°F
200 TO 1000°FCelsius Ranges
0 TO 50°C 0 TO 100°C
-40 TO 70°C
0 TO 400°C 100 TO 500°C
OptionsTemperature RangesSee pg.13 for a full list.
Fahrenheit Ranges-40 TO 160°F
*-Not available in 2.5" stem.*-Other sizes available
0 TO 150°C 0 TO 250°C
R E G I S T E R E DR E G I S T E R E D
StemLength
.75
.62
1/4" dia
Reset 3" dia (Model XR)
4" dia (Model Y) 5" dia (Model VR)
7
Heavy-Duty“Navy” Type
Bimetal ThermometersSilicone-Filled Thermometers
Specify option “SF” at the end of any 3”, 4” or 5” dial bimetal thermometer.(e.g., Model AA-040-1-F47-SF). See pg. 4-6
Heavy-Duty Navy TypeBimetal Thermometers
Any REOTEMP 3”, 4” or 5” dial bimetal thermometer (except Model DM4)can be silicone filled, in any stem length, and any temperature range up to550° F. (Silicone filling with ranges over 550° F not recommended.) Allsilicone-filled thermometers come with a durable polycarbonate crystal.
REOTEMP Silicone-filled thermometers are offered for severe industrial applications,where vibration is a problem. Silicone dampening prolongs instrument life by prevent-ing wear and fatigue in the instrument’s internal parts. The silicone also improvesreadability by reducing pointer flutter, and promotes faster temperature response.
Standard Features
• 3” Dial – Bimetal Actuation• Heavy Duty – Vibration and Shock Resistant• Stainless Steel – Sealed Construction• Plastic Crystal• External Reset is Standard• 1% Accuracy• Fits in 5” Scale “Submarine” Thermometer Well• 3/4” – 28 UN2A Union Connection – (to be used in thermowell)
AN2=AN4=AN6=
XN2=XN4=XN6=
F23F25F43F53F63F65F69F73
12"
12
"DIA.
34" STEM
LENGTH STEMLENGTH
1 5/16"
1.05"DIA.
1. Model2. Range
ThermometerWells STN2B
STN4BSTN6B
STN2SSTN4SSTN6S
STN2SSSTN4SSSTN6SSSWN2SSSWN4SSSWN6SS
Back (Angle) Form
Straight Form
Brass 304 SS 316 SS2" 3 1/4"4" 5 1/4"6" 7 1/4"2" 3 5/16"4" 5 5/16"6" 7 5/16"
Class A(3/4" NPT)
Class W(Socket Weld)
Model No.WellClass
ThermometerStem Length
Well Length(overall)
2” -40 TO 120° F in 2° divs.*4” -40 TO 180° F in 2° divs.6” 0 TO 200° F in 2° divs.
20 TO 240° F in 2° divs. 50 TO 300° F in 2° divs.
2” 50 TO 400° F in 5° divs.4” 50 TO 550° F in 5° divs.6” 50 TO 750° F in 10° divs.
-50 TO 50° C in 1° divs.*-10 TO 110° C in 1° divs. 0 TO 150° C in 2° divs. 0 TO 200° C in 2° divs. 0 TO 300° C in 5° divs.
M odels RangesFahrenheit Ranges
Celsius Ranges
*-4" M inimum stem length(on straight, left, or right side form s only)
Back Angle Form
Straight Form
Note: m inim um im m ersion length is 2” C13
C53C59C65C69
How to Order
How to Order
A & W Wells
8
REOTEMP INSTRUMENT CORPORATIONTelephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com
Bimetal ThermometersDual-Mode Thermometer
REOTEMP DUAL MODE THERMOMETER (model DMT) is a convenient, multipurpose indicator forlocal and remote temperature monitoring. This rugged dual-sensor system puts TWO SENSORS inONE THERMOWELL, and allows easy tie-in to process control. Both sensors are NIST traceable,and easily calibrated. Special sensor encapsulation and optional liquid filling make the DMT the mostrugged, durable instrument of its kind.
Bimetal Thermometer• Local easy-to-read Temperature Indication• Self-actuating, Dampened Bimetal Helix• Choice of three Dial Sizes, with Back, Bottom, or Adjustable Angle Connection• Hermetically Sealed per ASME B40.3• Thermometer is Easily Calibrated, and Field Replaceable• NIST Traceable Calibration
Thermocouple or RTD• Remote and Local Indication• Data Acquisition for Process Control• Choice of Connection Styles (see drawing below)• 4-20mA Transmitter Output Available
DMT Advantages:• Allows local and remote reading (Up to 1000°F) from one thermowell.• Bimetal dependability with RTD (or thermocouple) accuracy.• Redundant sensors for simple, effective calibration or spot checking without removing instrument from thermowell!• Easily installed in any standard thermowell.• Interchangeable with existing thermometer, RTD, Thermocouple.
Model DMT withScrew Cover TerminalHead, and Adjustable-Angle Head
with optional T/C Transmitter (HT)or with optiona RTD Transmitter (HR)
R E G I S T E R E DR E G I S T E R E D
9
Bimetal ThermometersDual-Mode Thermometer
Table 1 - Style & Stem Dia.
Table 2 - Stem Length
Table 6 - Thermowell (.385” & .260” bore)
TATCTBTLTMTJ
4A4C4B4L4M4J
02*04060912
1518243036
071072073074046047048049053054055056
171172173174146147148149153154155156
011012013014018019020021025026027028
111112113114118119120121125126127128
MPMC
EC
HAHTHR
Table 4 - Sensor
Case and Bezel: 304 SS (316 SS Available)Case Style: Back, Bottom or Adjustable Angle connection.Dial Size: 3”, 4” or 5”ProcessConnection: 1/2” NPT Standard, (1/2” NPT Union available)External Reset: Slotted Hex ScrewCrystal: Glass Standard, Plastic or Tempered Glass
optionalHermetic Seal: Bi-Metal Thermometer per ASME B40.3Stem: 304 SS, 0.375” O.D. (1/4” O.D. - specify
“DMT4”) Lengths from 2-1/2” to 36”RTD-T/C Encapsulation Sleeve (Pat.pending): 304 SSRTD:
Thermocouple: Type K grounded junction std. (Optional: typesT, E, J, or ungrounded.)
Connection: T/C plug, Mini connection head, or Standardscrew-cover connection head are available,Special customer requirements accommodated.
Ranges: Std. REOTEMP ranges and divisions to 1000F(500C)
Over Ranges: 50% over range to 550F, 1000F max.Accuracy: (+/-) 1% of full scaleThermowell: Model DMT fits any standard 0.385” bore
thermowell. (See table for Std. Models).Options: Silicone Case Fill for Vibration. (3/8” stem only)NOTE: Model DMT is intended for use ONLY in a thermowell. 3-A and NACE conformity available.
Model Style/Stem(Table 1)
Stem Length(Table 2)
Temp Range(Table 3)
Sensor(Table 4)
OutputConnection(Table 5)
Thermowell(Table 6)
* min. stem length 4” **continuous use over 800F not recommended.
Table 3-Temperature Range
F03F23F55*F43F47F53F63F65F69F79F85**
C03C23C55*C43C47C53C59C65C69C79C85**
D03D23D55D43D47D53D63D65D69D79D85**
Table 5 - Output Connection
TKTJTETTUKUJUEUTRCRK
100Ω (or 1000Ω optional) Platinum; 0.00385Ω/Ω/°C, 3-wire std.
DM TA 04 TK 046F24 MC
&&&&&&&&&&&
3/8" Stem 1/4" Stem3" Back Connected4" Back Connected5" Back Connected3" Adjustable-Angle4" Adjustable-Angle5" Adjustable-Angle
Code Description
Code Length Code Length2.5" 15"4" 18"6" 24"9" 30"
12" 36"
304 SS 316 SS 304 SS 316 SS4" 2.56" 4.59" 7.512" 10.54" 2.56" 4.59" 7.512" 10.54" 2.56" 4.59" 7.512" 10.5
1/2" NPT
3/4" NPT
1" NPT
1/4" Stem3/8 StemProcessConnection
StemLength
"U"Dim
DMT Specifications
Code DescriptionMini - Plug Receptacle (Thermocouple Only)Mini - Connection Head, w/screw terminals & protection head1/2" NPT Male Electrical Connection, w/Lead Wire
with Terminalwith 4-20 mA Transmitter (for Thermocouple)with 4-20 mA Transmitter (for RTD)
Aluminum screw - Cover Head w/3/4" NPT Conduit Connection
CodeThermocouple, Type K (grounded)Thermocouple, Type J (grounded)Thermocouple, Type E (grounded)Thermocouple, Type T (grounded)Thermocouple, Type K (ungrounded)Thermocouple, Type J (ungrounded)Thermocouple, Type E (ungrounded)Thermocouple, Type T (ungrounded)RTD, 100 ohm, 3-wire max. RTD, 1000 ohm, 3-wire 550°F
Description
Code Degrees F Code Degrees C Code-100 TO 100°F -70 TO 70°C -100 TO 100°F -70 TO 70°C 40 TO 160°F -40 TO 70°C 140 TO 160°F -40 TO 70°C 25 TO 125°F 0 TO 50°C 25 TO 125°F 0 TO 50°C 0 TO 200°F 0 TO 100°C 0 TO 200°F 0 TO 100°C 0 TO 250°F -20 TO 120°C 0 TO 250°F -20 TO 120°C 20 TO 240°F -10 TO 110°C 20 TO 240°F -10 TO 115°C 50 TO 300°F 0 TO 150°C 50 TO 300°F 10 TO 150°C 50 TO 400°F 0 TO 200°C 50 TO 400°F 10 TO 200°C 50 TO 550°F 0 TO 300°C 50 TO 550°F 10 TO 290°C 100 TO 800°F 50 TO 400°C 100 TO 800°F 40 TO 400°C 200 TO 1000°F 100 TO 500°C 200 TO 1000°F 100 TO 500°C
Degrees F & C
How to Order
* available only with3/8” dia. stem.
Block
10
REOTEMP INSTRUMENT CORPORATIONTelephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com
1/4" dia
1.16 dia
.33 dia
.29
.17
.24
StemLength
.33 dia
.30
.17
.24
StemLength
1.70 dia
1/4" dia
Model Q - 1 5/32” Dial Model G - 1 11/16” Dial
Bimetal ThermometersOEM Dial Bimetal Thermometers
REOTEMP OEM Thermometers (Models Q, G, and H) are the perfect choice for equipment with limited space andrequiring a rugged, dependable and economical temperature sensor. Available with a wide variety of mounting threads.
Mounting Thread Options
.24
StemLength
1/4" dia
2.37 dia
.36
Model H - 2 3/8” Dial
QQ 025 2 F43 PS
1/4” Dia.
QQ =
GG =
HH =
QP =
GL =
HL =
025 =
040 =
060 =
090 =
120 =
150 =
180 =
240 =
300 =
360 =
2 =
1 =
3 =
4 =
6 =
7 =
8 =
F23F55*F43F47F63F67F81F85
C23C55*C43C47C63C67C81C85
D23D55*D43D47D63D67D81D85
&&&&&&&&
PS =
SS =
PC =
PB =
How to Order
R E G I S T E R E DR E G I S T E R E D
Model Q 2.5" Plain Bushing (std.) Pointed Stem(1-1/4" dial)
4" 1/2" NPT 316 SS StemModel G(1-3/4" dial) 6" 3/8-24 NF Plastic Window
(straight threaded)Model H 9" Plain Bushing(2-3/8" dial) 1/4" NPT (non-reset)*
12"1/8" NPT
Model QP 15"(1-1/4" dial) 3/8" NPT5" Stem 18"
Hex Reset BushingModel GL 24"(1-3/4" dial)8" Stem 30"
Model HL 36" -40 TO 160°F -40 TO 70°C(2-3/8" dial) 25 TO 125°F 0 TO 50°C8" Stem 0 TO 200°F 0 TO 100°C
0 TO 250°F -20 TO 120°C 0 TO 300°F 0 TO 150°C 50 TO 500°F 0 TO 250°C150 TO 750°F 0 TO 400°C
200 TO 1000°F 100 TO 500°C
*for lab and test Models only
Options
OEM Models Fahrenheit Ranges
Models StemLength Connection Temperature Ranges
(See pg 13 for full list)
0 TO 300°F 50 TO 500°F150 TO 750°F
-40 TO 160°F 25 TO 125°F 0 TO 200°F 0 TO 250°F
200 TO 1000°FCelsius Ranges
Lab & Test Models -40 TO 70°C 0 TO 50°C
0 TO 100°C -20 TO 120°C 0 TO 150°C 0 TO 250°C 0 TO 400°C 100 TO 500°C
Dual F/C Ranges
*-Other sizes available *-Not available in model Q.
-Intermediatelengths available
up to 80"
-specify length ininches + tenths
1/2” NPT 3/8” NPT 3/8-24 UNF 1/4” NPT 1/8” NPT9/16” HEXBUSHING
11
Compost ThermometersBimetal Thermometers
Standard Features
• Hermetically sealed — will not fog• Pointed stem for easy insertion• Rugged, all stainless construction• Heavy duty 5/16” diameter stem• Easy to read 3” diameter dial• Unbreakable plastic crystal• °F & °C scales available
(Std. range, 0 - 200°F)• Accuracy +/- 1% of scale• Stem lengths up to 72” available
8"Stem
1.70" dia
.30
.24
1/4" dia
9/16" HEXRE-SET BUSHING1/4" dia
9/16" HexRe-set Bushing
6"Stem
1.16" dia
.30
.24
.24
8" Stem
1/4" dia
2.37" dia
.36
9/16" HexRe-set Bushing
Model QP - 1 5/32” Dial Model HL - 2 3/8” DialModel GL - 1 11/16” Dial
For Composting Food andYard Waste
Used By:
Waste Treatment Plants.City, State and FederalRecycling Programs.Farms and UniversityCompost Programs.Compost Chicken, Hogand Fish wastes.Mushroom Farms.
Standard Model: A36 PF (36” Pointed Stem, 0/200° F)Also Backyard Compost Thermometer:
G20P (2” Dial, 20” Stem, 0/200° F)
REOTEMP Laboratory Thermometers (QP, GL & HL) are ideal for testing and spot checking local temperatures in avariety of critical process or lab applications. Pointed stems are available for insertion in semi-solids such as soil, meat, etc.
Bimetal ThermometersHand-held Laboratory Thermometers
Ideally suited for monitoring interiortemperature of compost bins orwindrows.
Applications
Specify Model and Range (see table, pg. 10), Example: QP - F43
(with point - Model QPP) (with point - Model GLP) (with point - Model HLP)
How to Order
12
Sanitary Bimetal ThermometersSani-Temp
REOTEMP SANI-TEMP Bimetal Thermometer is specially designed for di-rect insertion into sanitary process applications when a standard thermowellis not specified or the process environment is not exposed to pressure. TheSANI-TEMP provides a quick temperature response and will mate with exist-ing process connections. The SANI-TEMP is ideal for the food, beverageand pharmaceutical industries.
• Quick connect Tri-clamp design• Fast installation and removal• Hermetically sealed case• Ideal for CIP and SIP• Designed to meet 3A Sanitary standards• External Reset
REOTEMP INSTRUMENT CORPORATIONTelephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com
Specifications
Dial Size: 3” 4” 5”Wetted Parts: 316/316L polished stainlessCase & Ring: 300 series polished st. stl.Process Connection: Tri-clamp (standard),
Cherry-Burrell (optional)Windows: Glass- (standard) see option
tableOptional: Acrylic, Polycarbonate, or
Tempered Glass Silicone Filling available for Vibration
“C”Dia.
Tri-Clamp 3/4" 3" 2 1/2" -40 TO 160°F -40 TO 70°C(standard) 4" 25 TO 125°F 0 TO 50°C
1" or 1 1/2" 5" 4" 0 TO 200°F 0 TO 100°C 0 TO 250°F -20 TO 120°C
2" 6" 20 TO 240°F -10 TO 110°C 50 TO 300°F 0 TO 150°C
2 1/2" 3" 9" 50 TO 400°F 0 TO 200°C4"
3" 5" 12"-40 TO 160°F -40 TO 70°C
15" 25 TO 125°F -5 TO 50°C 0 TO 200°F -10 TO 90°C
3" 0 TO 250°F -20 TO 120°C4" 20 TO 240°F -10 TO 115°C5" 50 TO 350°F 10 TO 150°C
50 TO 400°F 10 TO 200°C
OtherTypes
AvailableSee pg. 5
OtherStems
Available
Dual F/C Ranges
Farenheit Celsius
Temperature Range(See pg. 13 for a full list.)
FlangeType
SanitaryFlange Sizes
BimetalModels
StemLengths
Angle
BackConnected
BottomConnected
Adjustable
See pg. 4
See pg. 6
How to Order
Use “How to Order” Codes onpg. 4, 5, 6.
Specify Sanitary Connection.M =
C =
L =
A =
T =
A =C =B =
XR =Y =
VR =
L =M =J =
F23F55*F43F47F63F67F81F85
C23C55*C43C47C63C67C81C85
D23D55*D43D47D63D67D81D85
&&&&&&&&
How to Order
Stem LengthCustomer Specified
ThermometerHead
Sanitary Flange "C"see chart
14" dia
13
Sanitary Bimetal Thermometers
Bimetal ThermometersAccessories
Temperature Ranges
Code Description ModelMinimum or Maximumresettable pointer (one hand) 3”, 5”
Minimum and Maximumresettable pointer (two hands) 3”, 5”
Tempered Glass Lens 3”, 4”, 5”Plastic Lens AllSilicone Filled 3”, 4”, 5”Silicone Filled, food grade 3”, 4”, 5”Glycerine Filled 3”, 4”, 5”Pointed Stem All316SS Head and Bezel 3”, 4”, 5”316SS Stem All5/16” diameter stem 3”, 4”, 5”3/8” diameter stem 3”, 4”, 5”3/8” diameter aluminum sleeve 3”, 4”, 5”Teflon Coating (stem only) AllExternal Mounting Brackets G, HStainless Steel Tags AllPaper Tags AllNo Logo Dial AllBBQ Dial 3”
AccessoriesAS-86 Adapter Kit: permits
installation of bimetal thermometer in existingmercury-in glass-industrialthermometer thermowell.
HT Heat Transfer Compound(2 oz, 1 lb containers)
D3 Duct Flange (1/2" NPT)CH T-27 spring handleCP Pan Clip
CalibrationCC Certificate of ConformanceC1 1 Point Calibration
CertificateC3 3 Point Calibration
Certificate
Also available on request – Custom dials, special ranges, special configurations.
Options
F03F07F11F21F23
F19F31F35F55F37F39F43F45F47F53F63F65F67F69F79F81F85
C03C07C11
C23
C19C31
C55C37
C43
C47C53C63C65C67C69C79C81C85
D03
D11
D23
D55D37D39D43
D47D53D63D65D67D69
D81D85
MM
MATGPCSFSDGFPS3HSSF5S3F3TFMBTSTPNLBQ
Bimetal Temperature Range Master List - (Other ranges available on application. Y = available)
* = Minimum stem 4"** Includes all 3", 4", and 5" models (back, bottom, or all-angle)
R E G I S T E R E DR E G I S T E R E D
Code F Ranges Div Q G H 3,4,5** Code C Ranges DivQ G H 3,4,5** Code Q G H 3,4,5**-100/100F 2 Y Y Y -70/70C Y -100/100F & -70/40C Y Y Y-80/120F 2 Y Y -50/50C 1 Y Y Y-70/150F 2 Y -50/100C 2 Y Y Y -50/210F & -50/100C Y-40/120F 2 Y-40/160F 2 Y Y Y Y -40/70C 1 Y Y Y Y -40/160F & -40/70C Y Y Y
-50/200C 2 Y-50/300F 2 Y Y Y -40/160C 2 Y-20/120F 2 Y Y -20/40C* 1 Y0/100F* 1 Y25/125F* 1 Y Y Y Y 0/50C* 1/2 Y Y Y 25/125F & -5/50C* Y Y Y0/140F 2 Y 0/60C* Y 0/140F & -15/60C Y Y0/150F 1 Y Y 0/150F & -20/70C Y0/200F 2 Y Y Y Y 0/100C 1 Y Y Y Y 0/200F & -10/90C Y Y Y Y0/220F 2 Y Y Y0/250F 2 Y Y Y Y -20/120C 2 Y Y Y 0/250F & -20/120C Y Y Y
20/240F 2 Y Y Y -10/110C 1 Y Y Y Y 20/240F & -10/115C Y Y Y50/300F 2 Y Y Y Y 0/150C 1 Y Y Y Y 50/300F & 10/150C Y Y Y50/400F 5 Y 0/200C 2 Y Y Y Y 50/400F & 10/200C Y50/500F 5 Y Y Y Y 0/250C 2 Y 50/500F & 10/260C Y Y Y Y50/550F 5 Y Y 0/300C 2 Y Y Y Y 50/550F & 10/290C Y100/800F 10 Y Y Y 0/400C 5 Y Y Y150/750F 10 Y Y Y Y 50/400C 5 Y Y Y 150/750F & 70/400C Y
200/1000F 10 Y Y Y Y 100/500C 5 Y Y Y 200/1000F & 100/500C Y Y Y Y
Dual Ranges
14
Thermowells
Thermowells make it possible to remove instruments without dropping pressure or losing contents. Eachstainless Thermowell die stamped with type of material from which it is made.
REOTEMP INSTRUMENT CORPORATIONTelephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com
Features• Provides Sanitary Protection for Temperature Probes• All 316L Stainless Steel Construction• Fast Installation & Removal• Ideal for Food, Beverage, Biotech & Pharmaceutical Applications• Finish Exceeds Ra 32 max.• Exceeds 3A #4 Finish
STF-1.5-2.5STF1.5-4STF1.5-6STF1.5-9STF2-2.5STF2-4STF2-6STF2-9
STF2.5-2.5STF2.5-4STF2.5-6STF2.5-9STF3-2.5STF3-4STF3-6STF3-9
Example:1. Type:2. Thermometer Stem Length:3. Material:4. External Thread:
ST 4” 304 SS 3/4”
Sanitary Thermowells
“T” LagExtension
Type ST
Type LG
Models Material ExternalThread Options
"A" Dim "U" Dim 304 SS Socket-W eld 2 1/2" 1 5/8" W ell
4" 2 1/2" 316 SS6" 4 1/2" Optional: Tapered9" 7 1/2" Brass 1/2" NPT
12" 10 1/2" Straight15" 13 1/2" 1" NPT18" 16 1/2"
"A" Dim "U" Dim "T" Dim6" 2 1/2" 2"9" 4 1/2" 3"
12" 7 1/2" 3"15" 10 1/2" 3"18" 13 1/2" 3"24" 19 1/2" 3"
.385 Bore (for 3/8"
elements)
SantaryTri-Clamp
ST
LG(lagging)
Stem3/4" NPT
(Standard)
Carbon Steel
Threaded, for Bimetal Thermometers
Tri-ClampSize
"A" StemLengths Part No. "U" Dim "C" Dim
(Flange Dia.)2 1/2" 1 5/8"
4" 2 1/2"6" 4 1/2"9" 7 1/2"
2 1/2" 1 5/8"4" 2 1/2"6" 4 1/2"9" 7 1/2"
2 1/2" 1 5/8"4" 2 1/2"6" 4 1/2"9" 7 1/2"
2 1/2" 1 5/8"4" 2 1/2"6" 4 1/2"9" 7 1/2"
3.6
(76mm)
4.7
(91mm)
(51mm)
2
(63mm)
2.5
1 1/2"
2"
2 1/2"
3"
How to Order Specify Part Number:
How to Order
1/2” MAX O.D.
.260 BORE
R E G I S T E R E DR E G I S T E R E D
15
SHANK STYLES
Thermowells
Flanged Well
Sanitary Well
Standard Stepped Shank
Order By Specifying:1. Type and Bore Dia.2. Thermometer Stem “A” Length or “U” dimension.3. Material.4. Shank Style.5. For Flanged Wells: -Flange Size and Rating.6. For Threaded Wells: -Process Thread (P).7. For Socket-Weld Wells: -Nominal Pipe Size.
How to Order
Socket-Weld Well
Straight Shank
TYPESStandard Threaded Wells
R E G I S T E R E DR E G I S T E R E D
Tapered Shank
3/8" DIA
(.250 DIA)
A
U
C
1/2" NPT
1/8"
1/4"
AELEMENT LENGTH
2-1/4
Q
BORE
UINSERTION LENGTH
1-1/4" dia
FLANGE SIZE & RATINGCUSTOMER SPECIFIED
1/4"
A
U
P
1-3/4"
Q1
1/4"BORE SIZEQ2
1/2" NPT
1.0A
1/2" NPT
P
(.75) BORE DIA
U
Q
(.50)
1/4"
Q1
Q2
Q
Q1
Q2
Type ElementLength Material Shank
StyleFlange Wells
Socket-Weld Wells
or (U-dim) Flange Sizeand Rating
Pipe SizeNom.
304 SS Stepped Example: Example:316 SS Straight 1 1/2", 150# 3/4" Pipe
Flanged Carbon Steel TaperedSocket Weld BrassSanitary Type 316L SS
MonelHastelloy BHastelloy C
TitaniumTantalum
Teflon
Externally Threaded(Standard Bimetal Type)
Call Factory for help specifying well, if needed
See Table pg. 14
16
Liquid-In-Glass ThermometerAll Angle Industrial
Case: Modern V-shape design with parts molded of GE Valox®polyester, in black textured finish. Heavy glass protected front firmlysecured by spring action.
Stem: Tapered bulb chambers are made of precision ground alumi-num. The tapered chamber forms a metal contact with matchingtaper in the sockets assuring maximum speed of response totemperature changes. Graphite is used as a conducting mediabetween bulb chamber and glass tube.
Locking Device: Adjustable case locknut and angle adjusting screwwork independently to provide full 360° positioning of thermometercase and stem.
Tube & Capillary: Mercury filled-magnifying lens “Red Reading”tube (Spirit Filled option available). Precision made to guaranteeaccuracy within 1% of scale range. Silicone shock mounting forlasting durability. When Mercury is not desired, alcohol-based spiritfill is available
Scale: 9" scale with white coated aluminum and permanently bakedbold black markings.
Applications: REOTEMP “All Angle” Industrial Thermometers areused in pipelines of all types, commercial building application(heating & cooling), process piping, tanks, boilers, etc.
REOTEMP INSTRUMENT CORPORATIONTelephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com
9” Scale, All Angle with1 1/4”-18” Swivel Nut
INDUSTRIAL THERMOMETERS
RETORT THERMOMETERSFor Rubber Vulcanizers, Retorts,
Coolers, Kettles.9” Scale Straight or Angle Form,
3 ½” 304 SS Stem, with ¾ NPT 304 S.S. Hub.
9RA35F9RS35F9RA35C9RS35C9RA35FV9RS35FV
Separable Sockets¾” NPT External
SOC35BSOC06BSOC09B
SEN06BSEN09B
UH3B
SOC35SSOC06SSOC09S
SEN06SSEN09SUH3S
Specifications:
9VS359VS069VS09
9VX359VX069VX09
How to Order 016 SOC35B
Mercury Filled Spirit Filled3 ½"6"9"
Part #Stem
9VX35
STANDARD
411118212012016318324330
Code Range Divisions-40 TO 110°F 2°-10 TO 180°F 2°-20 TO 120°F 2° 0 TO 120°F 1° 0 TO 160°F 2° 30 TO 180°F 2° 30 TO 240°F 2° 30 TO 300°F 2°
Union Hubs
1. Part #2. Range Code3. AccessoriesShaded items normally instock.
StemLength
InsertionLength
Extension Neck
LengthBrass 304 SS
3 ½" 2 ½" -6" 5" -9" 8" -
6" 2 ½" 2 ½"
9" 5 ½" 2 ½"¾ NPT External Thread
Range Form Part #170/270°F & 0/30psi Angle170/270°F & 0/30psi Straight
80/130°C & 0/2 kg/cm2 Angle 80/130°C & 0/2 kg/cm2 Straight200/400°F & 0/200psi Angle200/400°F & 0/200psi Straight
A
U
U
AT
1"
17
REOTEMP remote Vapor actuated Thermometersare manufactured to the highest standards for awide range of uses and may be fitted into almostany temperature indicating application. Theseinstruments are ideal for remote reading, such aspanel installations, with capillary lengths of 1 to100 feet.Being vapor actuated, they are not subject toindicator error due to ambient temperature varia-
tions along the capillary tube system, and will giveexcellent readings provided the temperature beingmeasured is above or below ambient temperature.
Vapor instruments have progressive graduations,and are best read in the upper 2/3 of the dial range.Many ranges are available between –40°F and+450°F, and care should be exercised to select arange that will locate the operating temperatureswithin the upper 2/3 of the dial range (see ranges onback page).
Filled System ThermometersVapor Actuated
Window: Polycarbonate, or Glass.Bulb: Stainless Steel or copper. Bulb O.D. 7/16"(threaded), 3/8" (plain). Bulb lengths vary from 2 ½”to 9 ¼” depending on capillary length.Capillary: Copper, copper with bronze braid armor,stainless steel, stainless steel with stainless steelarmor. Capillary lengths 1 to 100 feet (standard length5 feet).Ranges: Over twenty °F and °F/°C ranges available,from –40° to + 450°F (see illustration, back page).Applications: Control panels, chemical processing,pipelines, food processing, OEM applications, ovens,solar heating, refrigeration, etc.
Specifications:Dial Sizes: 2", 2 ½”, 3 ½”, 4 ½”Dial: Aluminum with white finish and black markings, othercolors available.Pointer: Standard adjustable.Movement: Brass with precision gearing.Bourdon Tube: Phosphor bronze.Accuracy: Plus or minus one scale division.Case: All stainless steel, except: VA45FL (Aluminum)VA45TB (Phenolic).Process Connection: Plain Bulb, 1/2" NPTUnion, ½” NPT sliding union on 12" bendable extension, orThermowell. NOTE: Thermowells must be used wheneverthe bulb would be exposed to pressure, fluid velocity, orcorrosive media
R E G I S T E R E DR E G I S T E R E D
18
REOTEMP INSTRUMENT CORPORATIONTelephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com
Filled System ThermometersVapor Actuated - How to Order
Table 1 - Case StyleFront Flanged (Panel Mount)
U-Clamp (Panel Mount)
Rear Flanged (Panel Mount)
20FR25FR35FR45FR45FL
20UR25UR35UR
20RR35RR35RB45RR45RB45TB
35SB45SB35DA45DA
Code Dial Case Lens Connection Location3 1/2" SS Polycarbonate4 1/2" SS Polycarbonate
3 1/2" SS Polycarbonate4 1/2" SS Polycarbonate
Adjustable BracketMount
"Direct" adj. Mountw/3.4 Cu bulb, 1/2" NPT*
Code Dial Case Lens Connection Location2" SS Polycarbonate* Rear
2 1/2" SS Polycarbonate* Rear3 1/2" SS Polycarbonate* Rear4 1/2" SS Polycarbonate* Rear
4 1/2" Black Aluminum(hinge ring type) Glass Rear
Code Dial Case Lens Connection Location 2" SS Polycarbonate* Rear
2 1/2" SS Polycarbonate* Rear3 1/2" SS Polycarbonate* Rear
Code Dial Case Lens Connection Location2" SS Polycarbonate* Rear
3 1/2" SS Polycarbonate* Rear3 1/2" SS Polycarbonate* Bottom4 1/2" SS Polycarbonate* Rear4 1/2" SS Polycarbonate* Bottom4 1/2" Phenolic Glass** Bottom (Turrent Mount)
Model VVapor
Actuated
Case Style& Size
(Table 1)
TemperatureRange
(Table 2)
Capillary& Bulb
(Table 3)
CapillaryLength (in Ft.)
(Table 4)
ProcessConnection
(Table 5)
V 20FR 21 05 L2D
*Glass lens available, specify “Glass Lens”**Polycarbonate, lens available, specify “Poly Lens”
Other Case Styles
*Specify Model & Range Only.Example: V45DA-80
*
19
Filled SystemThermometersVapor Actuated - How to Order
Table 4 -- Capillary Length
Table 3 -- Capillary & Bulbs
Code Capillary &Bulb Material
CapillaryProtection
Copper NoneCopper Bronze Braid316 SS None316 SS S.S. Armor
Table 2 -- Temperature RangesCode °F Ranges Code
-40 TO 60°F -40 TO 60°F -40 TO 15°C -40 TO 110°F -40 TO 110°F -40 TO 40°C -20 TO 120°F -20 TO 120°F -30 TO 50°C 0 TO 180°F 0 TO 180°F -20 TO 80°C 0 TO 150°F 0 TO 150°F -15 TO 65°C 20 TO 220°F 20 TO 220°F 0 TO 105°C 40 TO 240°F 40 TO 240°F 0 TO 115°C 0 TO 250°F 0 TO 250°F -20 TO 120°C 30 TO 300°F 30 TO 300°F 0 TO 150°C100 TO 350°F 100 TO 350°F 40 TO 175°C200 TO 450°F 200 TO 450°F 100 TO 230°C
°F and °C Ranges
Table 5 --Process
Connection
ThermowellsFor VaporActuated
Bulbs(except M2)
CAPILLARY PLAIN BULB UNION CONNECTION THERMOWELL BENDABLE EXT.LENGTH L D U S D U S D L S D
1-10 ft. (bulb #1)21/2 (1-5ft.)
37/16 (6-10ft)
11-25 ft. (bulb #2) 37/163/8 21/2 31/4 7/16 25/8 33/8 9/16 37/16 4 - 14 3/8
26-50 ft. (bulb #3) 47/8 3/8 41/2 51/4 7/16 45/8 53/8 9/16 47/8 5 - 15 3/8
51-75 ft. (bulb #4) 77/8 3/8 61/2 71/4 7/16 65/8 73/8 9/16 77/8 8 - 18 3/8
76-100 ft. (bulb #5) 107/8 3/8 81/2 91/4 7/16 85/8 93/8 9/16 107/8 11- 21 3/8
3/8 113/16 23/8 7/16 115/16 21/2 9/163/8
21/2 (1-5ft.) 3 - 1337/16 (6-10ft) 4 - 14
20303272498050566068*70*
213133737981515761*66*71*
ACDE
J1J2J3K2L2M2
Code Connection Type MaterialNone (Plain Bulb)
Jam Nut Only Brass - (For Existing Brass Well)Jam Nut Only 316 SS - (For Existing Stainless Well)
1/2" NPT Union Brass 1/2" NPT Union 316 SS
1/2" NPT Sliding Union on Bendable Extension 316 SS - (Only Avail. with 316 SS Capillary)
Note: Capillary Lengths over 5 feet affect bulb length. See table at bottom of page.
12B
22B
32B
42B
52B
Union ConnectionPlain Bulb ThermowellBendable Extension
Bulb Configurations
Standard Bulb Dimensions (inches)
Specify Length in feet.Standard Length = 5 Ft.
Available Capillary Length: 1-100Ft.
&&&&&&&&&&&&
*Ranges over 300° come with316SS Capillary only.
1/2 NPT 3/4 NPT 1/2 NPT 3/4 NPTFor 1-10 ft. Capillary (bulb #1)
For 11-25 ft. Capillary (bulb #2)
For 26-50 ft. Capillary (bulb #3)
For 51-75 ft. Capillary (bulb #4)
For 76-100 ft. Capillary (bulb #5)
316 SSBrass
13B
23B
33B
43B
53B
12S
22S
32S
42S
52S
13S
23S
33S
43S
53S
L
DU
D
SU
D
SL D12"
S
R E G I S T E R E DR E G I S T E R E D
20
Filled System ThermometersVapor Actuated
REOTEMP INSTRUMENT CORPORATIONTelephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com
No. 21
No. 61
No. 73
No. 31
No. 66
No. 79
No. 51
No. 81
Dial FacesTypical dial faces shown below; complete list shown on page 19.
Operating temperatures should be in upper 2/3 of selected range.
For Temperatures above or below those shown, ask for information on REOTEMP Gas Actuated Thermometers.
Front Flange U-Clamp Rear Flange
Case and Mounting Dimensions (inches)
Dial Sizes A B C D E F G H J2" 2.94 2.25 2.94 1.28R 2.05 0.98 1.28R 2.3 0.14
2 1/2" 3.69 2.81 1.66R 2.56 1 0.17
3 1/2" 4.75 3.97 4.75 2.16R 3.59 1.41RF.75UC, FF 2.16R 3.69 0.16
2.69R 4.69 0.224 1/2" 5.88FR6.31FL
5.88RR,RB5.83TB 2.69R
4.59FR47RR,RB, FL
1.41RF.75UC, FF
2.56TB1.63FL
CF C
FC
F
CF
CF
CF
CF
CF
21
Filled System ThermometersGas Actuated
REOTEMP Gas Actuated Thermometerscombine advanced gas coil technology with astate-of-the-art adsorbent (Class IV) thermalsystem, producing superior temperature mea-surement instrument that can be fitted to awide variety applications
Features include high accuracy, low ambienterror, no head error, and a high degree ofover-range protection. The compact (3/8” dia.x 3” active length) bulb, and a wide range ofcase styles and thermal systems, allow greatflexibility in installation.
The linear dial on all REOTEMP gas thermom-eters provides a consistent 1% accuracyacross the full span of each range. This,combined with over twenty Fahrenheit anddual ranges, from -320 F to +1200 F, providescomplete coverage of all normal temperaturerequirements.
SpecificationsAccuracy: +/- 1 % of full scale. Calibration to NISTtraceable standards.
Ranges: Twenty °F and °F & °C ranges available from-320°F to 1200°F.
Overrange: Minimum 50% of span above top of range,or 1300°F, whichever is less.
Ambient Error: 1/4% of span per 25°F change in am-bient temperature at midscale.
Dial Sizes: 41/2"& 6". Dials are white with black mark-ings.
Case Materials: Stainless steel, Phenolic,or Aluminum.
Case Styles: Panel Mount, Surface Mount, or Direct(stem) Mount.
Windows: Glass is standard. Shatterproof glassand acrylic are optional.
Pointers: Slotted adjustable type to permit zero-set adjustments.
Bulbs: 316 Stainless Steel, 3/8" dia. x 3" activelength. Other diameters and lengths are available.
Process Connections: Plain bulb; 1/2" NPTsliding union; 1/2" NPT fixed (on All-Angle); orthermowell. Note: Thermowells should be usedwhenever the bulb would be exposed to pressure,fluid velocity, or corrosive or abrasive media.
Thermal Systems: Stainless steel capillary withstainless steel spring armor (up to 40ft).Over 40 feet, stainless steel interlock armor is stan-dard. Direct mount stems, 316 SS, 4" to 48".
R E G I S T E R E DR E G I S T E R E D
22
Gas Actuated - How to Order
REOTEMP INSTRUMENT CORPORATIONTelephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com
Filled System Thermometers
Table 1Case Size
& Style
Table 2Thermal System
& Bulb
Table 4Temperature
Table 5Options
Table 3Capillary Length
(feet)
G 4 5 E R – 8 7 – L 1 5 – F B – X A W
Table 1-Case StyleWall Mount (“E” or “K” case)
Direct Mount (“D” case)
Panel Mount (“F”, “S” or “U” case)
“S” CaseS.S.,
Semi-FlushFront
Flange
“K” CaseS.S.,BackFlange
“D” CaseS.S.,All-AngleDirectMount
A
C
B
.75
A
C
B
D
3 HOLES G DIA. ONH BOLT CIRCLE
3 HOLESG DIA. ON
H BOLTCIRCLE
F
.44
3 HOLES GDIA. ONH BOLTCIRCLE
F
A B
D
180°ROTATION
BE
A
360°ROTATION
PANEL .5 MAX THK.88
DA
“U” CaseS.S.,
U-Clamp
“F” CaseAluminum
Front FlangeHinge Ring
B
F
E
D
C
A“E” CasePhenolicTurretMount
CASE CASECODE DIAMETER CONNECTION
G45ER 41/2" REARG45EL 41/2" LOWER
G45FR 41/2" REARG60FR 6" REAR
G45UR 41/2" REARG60UR 6" REAR
G45DA 41/2" ADJUSTG60DA 6" ADJUST
G45SR 41/2" REARG60SR 6" REAR
G45KR 41/2" REARG45KL 41/2" LOWERG60KR 6" REARG60KL 6" LOWER
41/2" “E” Turret Phenolic 5.83 2.56 5.08 2.62 1.0 .20 .24 5.3941/2" “F” Front Flange 6.31 1.63 - 4.88 - 1.35 .19 5.3841/2" “K” Back Flange 5.88 2.15 5.04 - - - 0.22 5.3841/2" “S” Semi-Flush 5.88 2.15 5.04 4.51 - 1.00 0.22 5.3841/2" “D” All Angle 5.04 2.00 - - 1.70 - - -41/2" “U” U-Clamp 5.04 - - 4.51 - - - -6" “F” Front Flange 7.87 1.59 - 6.34 - 1.75 0.19 6.696" “K” Back Flange 7.50 2.15 6.38 - - - 0.25 6.846" “S” Semi-Flush 7.50 2.15 6.38 5.88 - 1.00 0.25 6.846" “D” All Angle 6.38 2.15 - - 1.70 - - -6" “U” U-Clamp 6.38 - - 5.88 - - - -
Case Size Case Type A B C D E F G H
3 HOLES G DIA. ONH BOLT CIRCLE
G L X
Case Dimensions
23
Gas Actuated
CODE °F RANGES DIV.
Table 4-Temperature Ranges
FB -320/100°F 5°FE -120/120°F 2°FG -40/180°F 2°FH 0/120°F 1°FJ 60/120°F 1°FL 20/240°F 2°FN 0/300°F 5°FP 50/550°F 5°FR 50/750°F 5°FT 400/1200°F 10°
CODE °F & °C RANGES DIV.
DB -320/100°F / -200/40°C 5°/2°DE -120/120°F / -85/50°C 2°/1°DG -40/180°F / -40/80°C 2°/2°DH 0/120°F / -15/50°C 1°/1°DJ 60/120°F / 15/5°0C 1°/1/2°DL 20/240°F / -5/110°C 2°/1°DN 0/300°F / -10/150°C 5°/1°DP 50/550°F / 10/290°C 5°/5°DR 50/750°F / 0/400°C 5°/5°DT 400/1200°F / -200/650°C 10°/5°
Note: °C Ranges available on request
Specify Armored Capillary Length in Feet, up to 99 ft. (omit for “D” case).L05 = 5 feet L10 = 10 feet L15 = 15 feet…etc.Note: Stainless steel spring armor is standard protection on all capillary. Capillary over 40 feet requires XSI Spiral Interlock Armor option.
Table 3-Capillary Length
Filled System Thermometers
Table 2-Thermal Systems (all bulbs & capillaries are 316 SS)
All Angle Bulb
#11 bulb
#12 bulb
12"
.38 DIA. EXT/316, S.S.
BULB/316, S.S.
ARMOR
ARMOR 3"Active Length
.38 DIA.
.38 DIA.
.38 DIA.
REINFORCINGSPRING, S.S
Bendable Extension1/2" NPT
.38 DIA.
Stem Length
1/2" NPT
3"Active Length
3"Active Length
Extension Length
CODE DESCRIPTIONAll Angle Direct Mount with 1/2” NPT
(with “D” case only)4” stem x 3/8” diameter6” stem x 3/8” diameter9” stem x 3/8” diameter12” or longer stem x 3/8” dia. - specify stem lengthEXAMPLE: G45DA - 0X - 12” FB
0406090X
Plain Bulbs
Plain bulb, 3/8” x 3” active, + 12” rigidextension
Plain bulb, 3/8” x 3” active
11
12
Sliding 1/2” NPT onBendable Extension
3/8” x 3” active, 12” bendable extension
3/8” x 3” active, 18” bendable extension
3/8” x 3” active, over 18” bendable (Specify)
87
88
8X
3"Active Length
R E G I S T E R E DR E G I S T E R E D
24
XAW Acrylic Window (41/2" Cases only; not available in “F” Case).
XSG Safety Glass Window (41/2" Cases only; not available in “F” Case).
XMH Maximum or Minimum Hand.
XMM Maximum and Minimum Dual Hands.
XFR Flush Mounting Ring for “E” Case.
XBF 1/2" NPT Fitting for #11 Bulb - Fits on Bulb or extension.
XCF 1/2" NPT Fitting - Fastens on spiral interlock armor (requires XSI option).
XSI Spiral Interlock Armor (required over 40 feet).
XVD Vibration Dampening feature (dampens vibration - available in all rear connected models).
XTW Thermowell (see thermowell table below for order codes).
Code Description
REOTEMP INSTRUMENT CORPORATIONTelephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com
Gas Actuated
Table 5 - Accessories & Options
Thermowells for 3/8” dia. Elements
Filled System Thermometers
4 2 1/2 046 1466 4 1/2 047 147
3/4" NPT 9 7 1/2 048 14812 10 1/2 049 14915 13 1/2 050 15018 16 1/2 051 15124 22 1/2 052 152
4 2 1/2 053 1536 4 1/2 054 154
1" NPT 9 7 1/2 055 15512 10 1/2 056 15615 13 1/2 057 15718 16 1/2 058 15824 22 1/2 059 159
External Stem Insert OrderThread length Length Code
P A" U" 304 s.s. 316 s.s.
External Stem Insert Lag OrderThread length Length Ext. Code
P A" U" T" 304 s.s. 316 s.s.
Specify “TW” Plus Order CodeExample: TW-146
Lagging WellsStandard Wells
1/2" NPSM
STEM LENGTH A
3/4” NPT 6912151824
2 1/24 1/27 1/210 1/213 1/216 1/2
233333
247248249250251252
347348349350351352
1/2" NPSM
.385 DIA
STEM LENGTH A
How to Order
25
Filled Systems ThermometersDirect Drive Gas Actuated
Available in Four styles45GW WALL MOUNTED45GF FLUSH MOUNTED45GFF FRONT FLANGE45GAW ADJUSTABLE WALL
00 -200/100°C01 -100/100°C02 -30/60°C04 -10/80°C05 -30/120°C06 -10/150°C07 0/100°C08 0/200°C09 0/240°C10 0/300°C11 0/400°C12 100/400°C13 0/500°C14 0/600°C39 0/50°C
16 -350/150°F17 -100/100°F19 -40/120°F20 -40/200°F21 0/100°F23 0/150°F24 25/125°F25 0/200°F26 0/240°F27 0/300°F30 0/400°F31 0/500°F32 0/600°F33 150/750°F34 0/800°F36 0/1200°F38 20/240°F
Temperature Ranges
Celsius Ranges Fahrenheit Ranges
NITROGEN FILLEDDIRECT DRIVE SYSTEM
Specifications
Micrometer Adjustment Type
CASE:DIAL FACE:
LENS:POINTER:CAPILLARY:
ACTUATION:ACCURACY:
BULB:
Stainless Steel (SS)
+/- 1 % of Range Span
4 1/2" Satin Finish Aluminum, Black Lines andNumbers.Gasket Sealed Glass (Plexi Glass Optional)
Nitrogen thru SS Direct Drive Bourdon CoilSS Welded Construction
SS Protected by 1/4" Dia. Flexible SS Armor or3/16" Dia. Plain Armor
REOTEMP’s Rugged Direct Drive System makes our 45G seriesgas – actuated series the right choice for temperature indication inheavy duty or high vibration applications.
Its all-stainless steel case and internals, alongwith the direct drive system, result in superiorinstrument life in severe environments.
R E G I S T E R E DR E G I S T E R E D
26
REOTEMP INSTRUMENT CORPORATIONTelephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com
Filled Systems ThermometersDirect Drive Gas Filled Remote
Case Specifications
45GW =
45GF =
45GFF =
45GAW =
05 =
06 =
10 =
Other =
G112 =
G118 =
G212 =
G224 =
EC =
MP =
SG =
PC =
3/8” dia. bulb with 3/8” extension up to 48” withoptional 1/2” NPT compression fitting; All SS
3/8” dia. bulb with 3/16” bendable complete with 1/2” NPTcompression fitting; All SS
G2G1
Model 45GW
Model 45GF
Model 45GAWWall Mounted
Complete with Bracket
Flush Mounted Completewith U - Bracket
Adjustable Wall MountedComplete with Flange
45GW 06 08 G118 45SG
Model 45GFF
Bulbs
12”
Temperature Range
Wall Mount 5 Feet 12" Bendable Extension with 1/2" NPT Union Electrical Contacts
Flush Mount 6 Feet 18" Bendable Extention with 1/2" NPT Union Max Hand Pointer
Front Flange 10 Feet 12" Plain Bulb with Rigid Extension Tempered Glass
Adjustable Wall Mount
Specify Lengthin Feet
24" Bendable Extension with 1/2" NPT Union
Polycarbonate Crystal
Armored Capillary Length
See chart on Page 25.
Accessoriesfor Thermowells see pg. 24
Bulb TypeModel
Flush Mounted Completewith U - Bracket
How to Order
27
Filled Systems ThermometersDirect Drive Gas & Liquid Filled
Specifications:
Micrometer Adjustment Type
CASE:DIAL FACE:LENS:POINTER:
ACTUATION:
ACCURACY:
BULB:
Stainless Steel (SS)
+/- 1 % of Range Span
4 1/2" Satin Finish Aluminum, Black Lines and NumbersGasket Sealed Glass (Polycarbonate Optional)
45 LR - Inert Liquid thru SS Direct Drive Bourdon Coil (For*ranges, Nitrogen thru SS), Direct Drive Bourdon Coil.45GR - Nitrogen thru SS Direct Drive Bourdon Coil.
SS Welded Construction
45GR 06 08 ST6 316
45GR =
45LR =
02 =04 =06 =09 =12 =15 =
ST4316ST6316ST9316
EC =MP =
MODEL45GR
MODEL45LR
EVERY ANGLE
REOTEMP’s Rugged Direct Drive Systemmakes our 45GR and 45LR the right choice fortemperature indication in heavy duty or highvibration applications. Its all-stainless steelcase and internals, along with the direct drivesystem, result in superior instrument life insevere environments.
How to Order
Temperature Range
2 1/2" (LR Only)
4" "U" 3/8" 6" Dim. element9" 2.5"12" 4.5"15" 7.5"
p. 24 )
Tempered GlassPlastic Crystal
(More wells on:
Elec. ConnectionMax Pointer
p. 14
Accessories
4"6"9"
StemLength
Standard Thermowells (3/4"NPT, 316SS)1/4"
element
Gas Actuated3/8" Stem
Model
See chart on Page 25.
Armored Capillary Length
Inert LiquidActuated, 1/4" Stem
GXTW146GXTW147GXTW148
SG =PC =
R E G I S T E R E DR E G I S T E R E D
28
REOTEMP INSTRUMENT CORPORATIONTelephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com
Digital ThermometersHand-Held Thermometers
Model TM99A(with disposable battery)Model TC100A(with rechargeable battery)
Features• All Solid State• High Stability• Cold Junction Compensation• Wide Temperature Ranges
Features• All Solid State• High Accuracy• Detachable Probes• Wide Temperature Ranges
Probes for Models: HI 9063 and 701KFThermocouple Probes (intermediate sizes, orindustrial configurations avalaible on application)Probes have 4” handle and min. 36” lead, exceptwhere noted.
10K Thermistor ProbesAll but 2010 and 7041 have 3”handle and 48” coiled lead.
Probes for Models:TM99A and TC100A
Durable, shockresistant ABSplastic carryingcase
Model HI 9063Water Resistant Min - Max, °F/°C
Model 701K - Pocket SizeMagnet on back - stick it anywhereIn Stock in °F; Also available °C.Sealed
membranetouch pad
Easy-to-read,backlighted
LCD displaysboth °F
and °C
Model Description Probe Dimensions
S/S Immersion(comes standard) .142" x 4"
S/S PiercingTip Probe .041" x 2.8"
Fast Surface ProbeAir Probe .125" x 4"General Purpose Probe .18" x .6"
Model Description Probe Dimensions
Immersion/General Purpose .156" x 5"
Fast Response (no handle) 1/16" x 12"
Fast Response 1/16" x 4"Piercing Tip .156" x 4"Soft-wire Disposable (no handle) exposed tip 48"
Surface Temperature
Gas TemperatureHeavy Duty General Purpose 1/4" x 12"
Heavy Duty Penetration (pointed) .40" x 36", 48" or 60"
1075
1052
4040
50052010
LPK5
XPK2
FRK4HPK2REK1
LPK12LPKA
SPK1
MRK36,48,60
Specifications: TM99ATC100A HI 9063 701KF
Range & Resolution
-40F TO +300F(-40C TO +150C)0.1F or C Resolution
C/LO Mode: -50 TO 150C with 0.1C ResolutionC/HI Mode: -50 TO 950C with 1C ResolutionF/LO Mode: -58 TO 302F with 0.1F ResolutionF/HI Mode: -58 TO 1742F with 1F Resolution
-50 To 1,000F with 1F Resolution
Accuracy Greater of ±0.3F, or ±0.5% of reading ±0.3% Full Scale / ±3C (hi), ±0.6C (lo) ±.25%* (±1 Digit)Ambient Range 0 To 150F max, RH -90%, noncondensing -10 TO 50C (14 To 122F) RH 100% 32 TO 104FDisplay Backlighted .4" LCDProbe #1075 10K Thermistor, detachable Type K Thermocouple Type K Thermocouple (Optional)
Power TM99A - 9V alkaline battery (provided)TC100A - 9V NiCad battery with 110V charger 4 - 1.5V AAA batteries 1 - 9V battery
Size 9 1/2" x 6 1/2" x 2 1/2" (case closed) 7.7" x 3.1" x 2.4" (196 x 80 x 60mm) 3.1" x 2.4" x 1.1" (80 x 60 x 33.5mm)
TM99ATC100A
1. Specify Model #.2. Specify Probe. 701K SPK1
Model # Probe
Hand-HeldThermometer Models
701KHI9063
Disposable Battery
Rechargable Battery
Compact
Full Functioned
"K" ThermocoupleModels
ThermistorModels
How to Order
29
Thermocouples & RTD’s
TABLE D Resistance Temperatures Detectors
How to Order: Construct part number from table D below.
For Thermowell Assembly: Insert part number obtained below into assembly part number on page 31.
Insert single-digit number designated below. 1 (standard) -200 / +400°F (-130 TO +200°C) 2 (hi temp) -200 / +1100°F (-130 To +600°C)
Insert two-digit number designated be designated below. 18 = .188 dia. 25 = .250 dia. 37 = .375 dia.
Insert single-digit number designated below. 1 = 316 SS 3 = 304 SS 5 = INC 600
Insert single-digit number designated below.(STD) Platinum - 1 = 100 Ohms 2 = 200 Ohms 5 = 500 Ohms Nickel - 7 = 120 Ohms Copper - 8 = 10 Ohms
Specify lead length “B” in inches.(Omit for T/W assemblies, or where N/A)Need something you don’t see?
Call REOTEMP for information.•1-800-648-7737•
Choose from “Styles” table. Insert letter below. (for thermowell assemblies, specify style “A”)
STEP 3 - Temperature
STEP 4 - Sheath Diameter
STEP 5 - Sheath Material
STEP 6 - Resistance 32°F (0°C) Ohms ±.5% (#1 IS STANDARD)
STEP 7 - Determine the required length “L” in inches
STEP 9 - Lead Length
STEP 2 - Sensor Material (Px is standard)
STEP 1 - RTD Style
Insert letter designated below. Px - Platinum 0.00385 Ω/Ω/°C P - Platinum 0.00392 Ω/Ω/°C Pl - Platinum 0.00390 Ω/Ω/°C
N - Nickel 0.06725 Ω/Ω/°CC - Copper 000421 Ω/Ω/°CBa - Balco
For Thermowell assemblies, specify “AR” (as required)
Special Ranges available onapplication
RTD’s (Resistance Temperature Detectors)
RTD Styles
A
B
C
D
E
H
1/2 NPT Std.
B
B
Welded
Spring Loaded 1/2 NPT Std.
B
A standard RTD Assembly may be supplied withan adjustable compression fitting. Specify.
A standard 1/2 x 1/2 NPT stainless bushing is welded tothe element sheath. 1/4 x 1/4 and 3/4 x 3/4 are available.Specify.
A quick-disconnect male plug is mounted on the coldend of the element. Two or three prong standard plugsare available. Two prong miniature plugs areavailable. Specify.
A quick-disconnect female jack is mounted on thecold end of the element. Two or three prong standardjacks are available. Two prong miniature jacks areavailable. Specify.
This RTD is terminated with an “O” ring seal.Canister Head.
A standard 1/2 x 1/2 NPT stainless hex bushing allowsthe element to be spring-loaded up to 1/2.
STEP 8 - Number of Leads/RTD’sSingle RTD Leads/RTD Duplex RTD W 2-wire WW X 3-wire XX Y 4-wire YY
How to Order
R E G I S T E R E DR E G I S T E R E D
30
Mineral Insulated Thermocouples
REOTEMP INSTRUMENT CORPORATIONTelephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com
Thermocouples & RTD’s
Need something you don’t see?Call REOTEMP for information.
•1-800-648-7737•
Insert 2 digit number designated below.12 = .125in. 18 = .188in 25 = .250 in. 37 = .375in.
Insert single-digit number designated below. 1 = 316 SS 1700°F (927°C) 3 = 304 SS 1650°F (899°C) 2 = 310 SS 2100°F (1149°C) 5 = Inconel 600 2100°F (1149°C)
S = Single element assemblyD = Dual element assembly
Elements: G = Grounded U = Ungrounded
Length “L” in inches. For complete assembly withthermowell specify “AR” (as required).
“B” in inches (omit for thermowellassemblies, or where n/a)
TABLE C Thermocouples
Metal Sheathed Thermocouple Assembly - Insert “M”STEP 1
STEP 2 - Sheath Diameter
STEP 3 - ANSI Type Thermocouple Element
STEP 4 - Type of Sheath Material
Choose style from “Styles Table”. Insert letter(s) below. (For thermowellassemblies specify “A”)
STEP 6 - Number of Element
STEP 7 - Type of Junction
STEP 8 - Probe Length
STEP 9 - Specify Lead Length
M
Spring Loaded 1/2 NPT Std.
B
D
H
Thermocouple Styles
How To Order:Construct part number
from table “C”.
For Thermowell Assembly:
Insert part numberobtained below into
assembly part numberon page 31.
Thermocouple Styles
A
B
C
1/2 NPT Std.
B
B
Welded
Insert designation below.K = Chromel Alumel T = Copper ConstantanJ = Iron Constantan E = Chromel Constantan
Plain sheath with wire leads. Cold end epoxy sealed.Choose this style for Thermowell assemblies.
A standard 1/2 x 1/2 NPT stainless bushing is welded tothe element sheath.
Male Mini-plug is mounted to cold end of sheath. Standardsize plug available (specify).
A standard 1/2 x 1/2 NPT stainless bushing allows theelement to be Spring Loaded up to 1/2".
STEP 5 - Style
Female Mini-plug is mounted to cold end of sheath.Standard size plug available (specify).
How to Order
31
1 5/8"*L
Thermowell AssembliesThermocouples & RTD’s
ScrewCover Head
Table ABelow
ThreadedConnection
Table BBelow
ThermowellTable E (p.32) optional
2-1/2"* L
3"*L
5"*L
1L 1T
2L 2T
3L 3T
4T
Also Available:• Thermocouple Wire• Transmitters• Multipoint Thermocouple Assemblies• Protection Tubes• Stainless Steel Fittings
Example:
TABLE B Threaded Connection Configuration
CONFIGURATION: Dimen-sions are approximate.(with thermowell, sheathlength “L” does not have tobe specified)
StandardSteel
Fittings
Probe ElementThermocouples - Table C (pg.30)
or RTD’s - Table D (pg.29)
B – 1 L – M 25 K 3 A S G AR – S T 4 3 0 4
Head-Bushing
(Nom.)21/2"
Head-Nipple
Head-Nipple-Union
Head-Nipple-Union-Nipple
3" (Nom.)
UNIVERSAL CAST IRON TYPE A
UNIVERSAL CAST ALUMINUM TYPE B
FDA WHITE POLY TYPE S
EXPLOSION PROOF TYPE E
• Universal head• Cast iron• Heavy Duty• 1/2 NPT process with 3/4 NPT
conduit is standard
• Universal head• Cast aluminum• 1/2 NPT process with 3/4 NPT
conduit is standard
• Screw cover Poly head• Impervious to most
corrosive media• 1/2 NPT process with 3/4 NPT
conduit• SS Chain & Screws
• Explosion Proof• Cast aluminum
body & cap• For use with two wire transmitter• Rated for Class I, Groups C, D,
Class II, Groups E, F, G, Class III• 1/2 NPT process with 1/2 NPT
conduit is standard
TABLE A Screw Cover Heads
5”(Nom.)
(Nominal)1 5/8"
Transmitters - Specify 4-20mA transmitter by adding “X” to head type.Example: Type B head with Transmitter = BX (specify Temp. Range)Terminal Blocks - Standard in all heads.
4L
316 SSFittings
Stems are spring loaded*for positive contact withbottom of thermowell.
* For welded SS fittings, substitute”F” for “T” Example: 1F
R E G I S T E R E DR E G I S T E R E D
How to Order
32
Finished Assemblies - Ready to Go
REOTEMP INSTRUMENT CORPORATIONTelephone: (800) 648-7737 FAX (858) 784-0720 · [email protected] · www.reotemp.com
Thermocouples, RTD’s & Accessories
• Type K or J Thermocouple (single element, ungrounded)• Weatherproof Cast Aluminum Screw Cover Head, with Terminal Block• 316 SS Bushing, or steel Nipple• 1/4" dia. 316 SS Spring-loaded Stems, 4"’ 6"’ 9"’ or 12 “• Available for fast delivery
B1TM25K1ASU4B1TM25K1ASU6B1TM25K1ASU9B1TM25K1ASU12
B1TM25J1ASU4B1TM25J1ASU6B1TM25J1ASU9
B1TM25J1ASU12
B1TAPX125114XB1TAPX125116XB1TAPX125119XB1TAPX1251112X
Thermocouples
RTD’s (3-wire, 100 ohm)
Table E
Stem (L) Model #4"6"9"12"
Stem (L) Type K Type J4"6"9"12"
Popular Thermocouple & RTD Assemblies
B2LM25K1ASU4B2LM25K1ASU6B2LM25K1ASU9B2LM25K1ASU12
B2LM25J1ASU4B2LM25J1ASU6B2LM25J1ASU9
B2LM25J1ASU12
B2TAPX125114XB2TAPX125116XB2TAPX125119XB2TAPX1251112X
Thermocouples
RTD’s (3-wire, 100 ohm)Stem (L) Model #
4"6"9"12"
Stem (L) Type K Type J4"6"9"12"
TCX 001 T2TCX 001 T3TCX 001 T4
Other Accessories:
1 5/8"*L 5"*
L
Model # Description Model # DescriptionCast Iron Head Terminal Block, 2-wireCast Aluminum Head Terminal Block, 3-wireSpring loaded Bushing Terminal Block, 4-wire2 Wire Temperature Transmitter, 4-20 mA (specify calibration)
Head-Bushing Assemblies Head-Nipple-Union-Nipple Assemblies
Thermowells - Common Threaded Thermowells (3/4"NPT external thread).
For other similar wells, see complete listing, p. 14.
Field- Cuttable Thermocouples & RTD’s• Adjustable probe length, 2.5" to 18"• Probe is cut with simple tube cutter• One size fits many - simplify inventory.
TCX 006 ATCX 006 B
TCX BSL 22TCXT4
Thermocouples, Specify:1. Model (TC-1350 or RTD-1340)2. Sensor type (K, J, T, E, Etc.)3. G (grounded) or U(ungrounded)Example: TC-1350-K-G
For other similar wells, see complete listing, p. 24.
ST4304ST6304ST9304
GTXW046GTXW047GTXW048
GTXW146GTXW147GTXW148
ST4316ST6316ST9316
304 SS 316 SS4" 2 1/2"6" 4 1/2"9" 7 1/2"
StemLength
1/4" DIA. ELEMENTS"U"Dim 304 SS 316 SS
4" 2 1/2"6" 4 1/2"9" 7 1/2"
StemLength
3/8" DIA. ELEMENTS"U"Dim
R E G I S T E R E DR E G I S T E R E D
How to Order
How to OrderRTD’s, specify Model only.Example: RTD-1340
33
CIP Sanitary RTD’sThermocouples & RTD’s
ROETEMP’s Santary RTD’s are de-signed for temperature sensing in food,dairy, beverage and pharmaceuticalapplications where sensor corrosionand product contamination are critical factors.
Features:
Ideal for CIP (Clean-in-Place) All Sensors Highly Polished to Exceed 3A Requirements Quick-Connect Tri-Clamp Design Fast Response Tip Available Variety of Stem and Termination Options
Stem Options Termination Options
Standard Stem Type A
3”Immersion
X1/2”
1/4” OD, 316L SS
Sensitive Portion
S/S Sanitary Cap
3”Immersion
X1 1/4”
316L SS
S/S Sanitary Cap
Reduced Tip Stem Type B, C, E
4 1/2”
5/32” OD
X3/4”Tri-Clamp
Type D Mini-Stem with T-75 Mini-Cap
Connection Head Types S, Y (or Type T w/transmitter)FDA Compliant
White Polypropy-lene Screw CoverHead (Standard)
Type L (with Teflon Leads)
Type N (with Teflon Leads)
2 1/4”
1/2” NPT
ELead Length(STD. = 6”)
2 1/4”E
Lead Length(STD. = 6”)
All Stems are Polished 316L SS Other Options Available
See Easy “How to Order” guide on page 34.
34
CIP Sanitary RTD’s
REOTEMP INSTRUMENT CORPORATIONTelephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com
Thermocouples & RTD’s
• Alternate Wire Termination• Alternate Sanitary Cap Styles• Digital Indicating Meters (Suitable for Washdown)• Thermocouple Sensors (Sanitary & Industrial)
• RTD’s with CIP Sanitary Connected Wells• Penetration Probes• Chemical Resistant Thermocouples• Stainless Steel Tags
Other Available Options:
Other REOTEMP CIP Sanitary Products
L3 030 A T15 L 12
Description1.5" (Standard)2"3"3/4" Fractional (with "D" stem only)
Other Cap Styles Available - Please Specify
Description
Std. White Polypropylene Connection Head (FDA Compliant)
White Polypropylene Connection Head with 4-20ma Transmitter
White Epoxy Coated Aluminum Head
1/2" OD 316SS transition with (E") Teflon Leads (Specify Length, e.g. 12" = )1/2" NPT 316SS Threaded Fitting with Teflon Lead (Specify Length, e.g. 6" = )
T15 =T20 =T30 =T75 =
S =
T =
Y =
L =
N =
R
Table 1 - RTD Type
Accuracy # Elements0.10% 10.01% 10.10% 20.01% 2
100 ohm; .00385µ; 3 wire
Maximum temperature: 400°F (204°C)
L3 =H3 =L6 =H6 =
Table 2 - Immersion Length (X)Length Length
2" 6"3" 9"4" 12"
Long or intermediate lengths OKPlease specify length
020 =030 =040 =
060 =090 =120 =
Description1/4" Diameter
Reduced Tip (3/16" tip OD X 3/8" sheath OD)
Reduced Tip (1/4" tip OD X 1/2" sheath OD)
5/32" Diameter Tip (with T75 mini-cap only) Single Element Only
Special HTST Fast Response Reduced Tip (3/16 tip OD X 3/8" sheath OD, response time 3 to 3.5 sec.) Available in H3 & H6 RTD Type Only.
A =
B =
C =
D =
E =
Table 3 - Stem Style (All stems hightly polished to exceed 3-A#09-08).See stem options table pg. 33
Table 4 - Sanitary CapTri-Clamp Caps (Triclover 16 AMP Type)
Table 5 - Termination(See Termination Options pg. 33)
L12
N6
Sanitary PressureGauges
Sanitary Thermowells Sanitary PressureTransmitters
Sanitary BimetalThermometers
α
How to Order
35
Bimetal ThermometersSurface Thermometers
Bimetal ThermometersPocket Thermometers
Model # Temperature Ranges
K-79-2 -40 to 160°FK-79-3 0 to 220°FK-79-4 25 to 125°FK-79-5 50 to 550°F
K-79-7 -10 to 110°CK-79-8 0 to 150°CK-79-9 0 to 250°C
D-450 -40 to 450°FD-302 -58 to 302°F
Specifications
Accuracy - 1% of ScaleHead - 1” Diameter (25mm)Dial - White Background with crispletters, marks, and numbers.Stem - .142 OD, 5” long, pointed(3.6mm x 127mm)Reset Nut - 7/16” Hex (11mm)Pocket Case - Stainless Steel orPlastic with Clip and Holder LoopWeight - .65 ounces (18.5G)Packed - 1 per box, 12 per carton
Digital Pocket Thermometer
Model D-450
Resolution 0.1°F Stainless Steel Stem, .14 x 5” Accuracy 1% of span Comes with Pocket Case 1/4” High LCD Display
Also Available: D-302, -58 to 320°F
Analog (Dial) Models
Model K-79
Accurate & Rugged Quick Response Shock Resistant Sensitive Bimetal Element External Reset Adjustment Waterproof and Dustproof Stainless Steel or Plastic Pocket Case
Front View
Back View
Magnets
BimetalSensingElement
ProtecitiveCover andHeat Collector
How to Order
Digital Specifications
D-450 D-302
Range -40/450° F -58/302° FResolution 0.1° F 0.1° FAccuracy ± 0.8% of span ± 1% spanDisplay ¼” LCD ¼” LCDOFF Function 50 Min. Auto ManualUpdate 10 Seconds 4 Seconds
Specifications
Accuracy - Within 2% of full scaleHead - 2” (5.08cm)Dial - White Background, blue marks &numbersHeight - 1/2” (1.27cm)Weight - 2 ounces (56.7G) approx.Case - aluminum with optically clearcrystalSensing Element - precision calibratedbimetal coilResponse Time - approximately 1 minuteMounting - two Alnico magnets on back
Model # Temperature Ranges
SUR-15 0 to 150°F/-20 to 65°CSUR-50 0 to 500°F/-20 to 260°CSUR-25 0 to 250°F/-20 to 120°CSUR-75 50 to 750°F/10 to 400°C
Measures Temperature of any Horizontal Surface Magnetic Feet hold to any Ferrous Surface Used on Griddles, Ovens, Motors, Piping, Tanks, etc..
How to Order
How to
Analog
Digital
R E G I S T E R E DR E G I S T E R E D