Upload
others
View
0
Download
0
Embed Size (px)
Citation preview
Renu-a-WallExterior Renovation System
QUICK AND EASYQuick installation with an Easy price
BEFORE AFTER
W W W . S T R U K T U R O C . C O M
PROJECTS• Commercial Buildings• Strip Malls• Office Fronts• Parapets• Utility Buildings• Golf Course Buildings• DOT Buildings• Industrial Parks• Fascia Walls• Airport Hangars
PRODUCT• Substrate: 20 gauge, G90
• Galvanized Steel ASTM A924
• 20 Yr Warranty on Standard
Textured finish colors
• 30 YR WARRANTY ON
EMBOSSED KYNAR
• 24 gauge trims to match finish
• Non -Insulated
• Hidden Fastener
• Custom Trims available
• Architect and Design friendly
• Miami-Dade County Approved
FINISHES• Textured finish available in 24 standard colors. We will match custom colors. (sample must be sent in)• Embossed finish available in 6 standard colors.
INSTALLATION• Step 1 Insure that the existing exterior will hold screws and anchors (Block, Brick, Ribbed Panel, Wood)• Step 2 Install new trims around openings and base.• Step 3 Insulated Install hat channel• Step 4 Install Strukturoc wall panels, available in a textured (stucco) finish or an embossed finish.
Testing:• Adhesion-ASTM D2794 • Water Soak-ASTM D870 For Information Contact:• Formability-ASTM D1737 • Salt Spray-ASTM B-117 TransAmerican Strukturoc, Inc.• Color Retension-ASTM G26 • Weathering-G23 920 Apollo Road, Ste. 120• Structural-ASTM E1592 • Missle Test-ASTM E1886 Eagan, Mn. 55121• Racking Shear-ASTM E72-80 • Cyclic Pressure-ASTM E1996 952-884-7694
www.strukturoc.com
ATTACHEMENT DETAILS
Base Trim#168DC
J Trim#200CH
Drip Cap#180WDC
Strukturoc WallPanel System
Hat Channel#300A
Hat Channel#300A
Block Wall Detail @ Door Opening with Hat ChannelNote: Hat Channel is to be used @ 5' O.C. Max.
Block Wall
StrukturocWall Panel
Conc.Fastener:(By others)
StrukturocWall Panel
Conc.Fastener:(By others)
Outside CornerTrim #164OC
Blind Pop Rivet
Blind Pop Rivet
#14 X 7/8" T-1Panel FastenerBy Strukturoc(Optional)
#14 X 7/8" T-1Panel FastenerBy Strukturoc(Optional)
7/8" HatChannel
(300A)
7/8" HatChannel
(300A)
Block Wall Detail @ Outside Corner with Hat ChannelNote: Hat Channel is to be used @ 5' O.C. Max.
Strukturoc WallPanel
Drip Cap#180WDC
J Trim#200CH
Base Trim#168DC
Hat Channel#300A
Hat Channel#300A
Detail @ Door Opening with Hat ChannelNote: Hat Channel is to be used @ 5' 0" O.C. Max.
StrukturocWall Panel
StrukturocWall Panel
Outside CornerTrim #164OC
Blind Pop Rivet
Blind Pop Rivet
#14 X 7/8" T-1PanelFastenerBy Strukturoc(Optional)
#14 X 7/8" T-1PanelFastenerBy Strukturoc(Optional)
7/8" HatChannel
(300A)
7/8" HatChannel
(300A)
BUILDING GIRTS(By Others)
Detail @ Outside Corner with Hat ChannelNote: Hat Channel is to be used @ 5' 0" O.C. Max.
20 Ga. Galvanized (0.0396-in. Nominal Thk.)All Dimensions Out-to-Out Unless Otherwise Noted
1.125"
1.099"
0.747"
15.95"
0.577"
0.289"
3.1446"
0.866"
STK2000 Panel Profile
18.95"
www.strukturoc.com
• Coating ASTM 3363 • Water Soak ASTM D870
• Water Penetration ASTM E331-86 • Salt Spray ASTM B-117
• Color Retention (2000 hours) ASTM G7-05 • Weathering ASTM G7-05
• Structural ASTM E1592 • Air Infiltration ASTM E283-91
• Racking Shear ASTM E72-80 • Flammability ASTM E-84