Upload
lamthien
View
228
Download
0
Embed Size (px)
Citation preview
AEB INDUSTRIALE srlVia Brodolini 8 - 40056 Crespellano (Bo) - ITALIATel + 39 051 969870 - Fax + 39 051 969725Internet wwwdbtechnologiescomE-mail infodbtechnologies-aebcom
MANUALE DrsquoUSO - Sezione 1
USER MANUAL - Section 1
BEDIENUNGSANLEITUNG - Abschnitt 1CARACTERISTIQUES TECHNIQUES - Section 1
Cod 420120204 Rev 20
AC AC 26N26NREMOTE CONTROLLED AUDIO PROCESSOR
CA 26NCA 26N
REMOTE CONTROLLED AUDIO PRO ESSOR C
PushEn rte
Fsunction
eS lector
ESCME UN
C LH G STE NO IO E
Bd
cLo al
M
0
Italia
no
Italia
no
Manuale
drsquou
soM
anuale
drsquou
so
1
Italia
no
Italia
no
Manuale
drsquou
soM
anuale
drsquou
so
2
INTRODUZIONE
AC26N egrave un processore audio digitale per la gestione di sistemi audio progettato per installazioni fisse e touring AC26N utilizza la tecnologia piugrave moderna con processori a 2856bit e convertitori ADDA a 24-bit ad alte prestazioni
Contenuto della confezione- AC26N - Manuale drsquouso- CD software- Cavo di alimentazione
Caratteristiche- 2 Ingressi e 6 uscite con indirizzamento flessibile- Ingresso e uscita stereo AESEBU indirizzabili - DSP 2856-bit- Convertitori AD BURR BROWN 24-bit ad alte prestazioni- Frequenza di risoluzione filtri 1 Hz - 12 Equalizzatori parametrici per ciascun ingresso e uscita- 2 filtri crossover per ogni uscita con pendenza selezionabile 122448dBoct- DRC multiconfigurazione ad alte prestazioni per configurazione
limitercompressione per ciascun ingresso e uscita- Livello regolabile in dB polaritagrave e ritardo (delay) per ogni ingresso e uscita- Aggiornamento firmware tramite PC- Display LCD grafico- 32 preset memorizzabili dallrsquoutente- Interfaccia USB per controllo e configurazione da computer- Interfaccia RDnet che permette di controllare fino a 256 dispositivi remoti
Le funzioni disponibili nel processore sono livelli di ingresso e uscita ritardo (delay) polaritagrave 12 bande di equalizzazione per canale di ingresso e uscita molteplici selezioni di incrocio (crossover) e limiter ad alte prestazioni Il controllo dei filtri ha una risoluzione di 1Hz Ingressi ed uscite possono essere impostate in diverse configurazioni per soddisfare qualsiasi esigenza AC26N puograve essere controllato in tempo reale e configurato in ogni parametro dal pannello frontale e da computer con interfaccia grafica intuitiva accessibile tramite il software laquoDVA Networkraquo e un collegamento di rete dedicata RDnet oppure USBLrsquoaggiornamento del software per la CPU e DSP tramite PC permette di mantenere il dispositivo aggiornato Ersquo possibile salvare e richiamare 32 configurazioni predisposte di configurazione
PC
PC
RDNET control(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FUNZIONI PANNELLO FRONTALE
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
COMANDI E FUNZIONI1) DISPLAY
Il display LCD grafico permette di visualizzare ed editare le informazioni dellrsquoAC26N senza lrsquouso del computer Il contrasto puograve essere settato allrsquointerno del menu principale
2) MANOPOLA ldquoFuncions Selectorrdquo E ldquoPush Enterrdquo Questo controllo permette di muoversi selezionare e variare i parametri allrsquointerno dei menu visualizzati sul displayRotazione della manopola (Functions Selectors)- permette di muoversi allrsquointerno delle varia pagine del menu- permette la variazione dei parametri selezionatiPressione della manopola (Push Enter)- permette la selezioneconferma dei parametri
3) Pulsante ldquoESCrdquo Questo pulsante consente di uscire dai menu visualizzati o di ritornare alla visualizzazione precedente
4) Pulsante ldquoMenurdquo Questo pulsante permette di accedere direttamente al menugrave principale
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
DVA USB Manager
Il firmware del controller audio puograve essere aggiornato attraverso la porta USB Per rendere possibile e facile questo aggiornamento egrave stato sviluppato un programma dedicato
Si raccomanda di scaricare il software gratuito DVA USB Manager direttamente dal sito dB Technologies (wwwdbtechnologiescom) nella sezione dedicata laquoSoftware amp Controllerraquo
DVA Network
AC26N egrave equipaggiato con interfaccia di rete proprietaria denominata RDNET tramite la quale egrave possibile interfacciarsi al computer attraverso una periferica (RDNET control)A questo scopo egrave stato sviluppato il protocollo proprietario di comunicazione RDnet con il quale egrave possibile ricevere e inviare i dati questo collegamento permette di monitorare in tempo reale i parametri del diffusore come livello del segnale stato del limiter etc Ersquo possibile selezionare diversi valori di crossover delay volume ed aggiungere equalizzazioni tramite lrsquoapposito plug-in
Si raccomanda di scaricare il software gratuito DVA Network direttamente dal sito dB Technologies (wwwdbtechnologiescom) nella sezione dedicata laquoSoftware amp Controllerraquo
DOWNLOAD
DOWNLOAD
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquouso
Ma
nu
ale
drsquou
so
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquouso
Ma
nu
ale
drsquou
so
3 4
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
CONNESSIONI PANNELLO RETRO
1586 75 141210 11 13 169 17
14) Connettore ldquo USBrdquoQuesto connettore USB (tipo B) permette di collegare il processore ad un computer per il controllo e lrsquoaggiornamento del firmware tramite un programma dedicato (DVA Network)
15) PRESA DI ALIMENTAZIONE ldquoMAINSrdquoConsente la connessione del cavo di alimentazione fornito in dotazione
16) PORTA FUSIBILE ldquoFUSErdquoAlloggio per fusibile di rete
17) INTERRUTTORE GENERALE ldquoPOWERrdquoLrsquointerruttore permette lrsquoaccensione e lo spegnimento del controllore audio
COMANDI E FUNZIONI
5) SELETTORE ldquo-6dBrdquo
Ingressi bilanciati a livello lineaSono in grado di accettare connettori XLR maschio
Uscite bilanciate a livello linea Sono in grado di accettare connettori XLR femmina
Sezione ldquoAESEBUrdquo
8) CONNETTORE DI INGRESSO ldquoINrdquoIn aggiunta agli ingressi audio analogici egrave stato previsto un ingresso audio digitale SPDIF-AESEBU (AES3) selezionabile tramite il menu di setupLingresso richiede una connessione bilanciata utilizzando un connettore XLR con un cavo a 3 conduttori da 110ohm twistato
9) CONNETTORE DI USCITA ldquoOUTrdquoQuesto connettore permette di rilanciare il segnale audio presente negli ingressi analogici o digitali oppure presenti sulle uscite La sorgente deve essere impostata tramite il menugrave ldquoOptionrdquoLa connessione deve essere conforme allo stesso stardard dellrsquoingresso [rif8]
10) CONNETTORE DI INGRESSO DATA INPUTrdquoConnettore RJ45 ingresso dati
11) CONNETTORE DI USCITA DATA LINKrdquoConnettore RJ45 uscita dati per il collegamento seriale in cascata
12) INDICATORE LUMINOSO ldquoONrdquoQuesto indicatore di colore Verde si accende solo quando lrsquoAC26N ha riconosciuto ed egrave connesso con unitagrave principale RDNET tramite computer
13) INDICATORE LUMINOSO ldquoACTIVErdquoQuesto indicatore di colore Giallo lampeggia quanto egrave attiva una trasmissione dati tra RDNET e il dispositivo
Il selettore permette di ridurre di 6db i livelli di ingresso analogici XLR [6] contemporaneamente per compensare il livelli alti di uscita dei mixer o di altri dispositivi audio Quando la barra del livello segnale degli ingressi sul display [1] risulta sempre al massimo questo indica che il livello del segnale in ingresso egrave elevato e si consiglia di utilizzare lrsquoattenuazione -6dBErsquo possibile controllare quando il selettore egrave attivato dal menu ldquoOptionrdquo
6) CONNETTORI DI INGRESSO ldquoArdquo E ldquoBrdquo
7) CONNETTORI DI USCITA ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo E ldquo6rdquo
Prestare attenzione a collegare le uscite in modo corretto ai diffusori od agli amplificatori in base ai settaggi dei singoli canali per evitare danni e malfuzionamenti
Sezione ldquoRDNETrdquo
PUSH
P SHU
SHPU
P SHU
PUSH
COLLEGAMENTI
Audio analogiciLe connessioni bilanciate permettono di ridurre al minimo il rumore indotto dai cavi stessi e permettere la possibilitagrave di usare cavi di lunghezza importantiQueste connessioni possono essere utilizzate sia sugli ingressi che sulle usciteIl connettore XLR deve essere collegato con il pin 1 a massa pin 2 al caldo (+) e pin 3 al freddo (-) Nel caso di cavo schermato collegare la schermatura al pin 1I cavi ci connessione XLR-XLR e XLR-Jack14(63mm) possono essere utilizzati per il collegamento allrsquoAC26N
12
3
Ingresso
XLR - femmina
Pin 3 =NegativoFreddoFase -VE
1 2
3
Uscita
XLR - Maschio
Pin 2 = PositivoCaldoFase +VE
Pin 1 =SchermoTerraMassa
Pin 1 =SchermoTerraMassa
Pin 2 = PositivoCaldoFase +VE
Pin 3 =NegativoFreddoFase -VE
Anello
Gambo
Punta = PositivoCaldoFase +VE
Anello = NegativoFreddoFase -VE
Gambo=SchemoMassaTerra
Punta
Le connessioni sbilanciate possono essere utilizzate anche se il rumore indotto dai cavi stessi aumenta e i cavi non devono superare la lunghezza di 5mtQueste connessioni possono essere utilizzate sia sugli ingressi che sulle usciteI collegamenti sbilanciati possono abbassare il livello del segnale in ingresso di 6dB per ovviare a questo inconveniente egrave necessario collegare il pin 3 alla massa anche se questo puograve aumentare il rumore
12
3
Ingresso
XLR - femmina
1 2
3
Uscita
XLR - Maschio
Punta Gambo
Punta = Segnale
Gambo=SchemoMassaTerra
Pin 2 = PositivoCaldoFase +VE
Pin 1 =SchermoTerraMassa
Pin 3 = Connesso al Pin 1
Pin 3 = Connesso al Pin 1
Pin 1 =SchermoTerraMassa
Pin 2 = PositivoCaldoFase +VE
Audio digitali (AESEBU)AESEBU (protocollo AES3) egrave un ingresso bilanciato isolato elettricamente tramite un trasformatore Permette di utilizzare due canali audio in un singolo cavo bipolare schermato Le caratteristiche del cavo devono essere impedenza 100ohm twistato e schemato con connettore XLR (AES3 standard)
RD netCiascuna porta RDNet presente sui Control 2 e Control 8 puograve essere collegata a max 32 dispositivi compatibili posti in cascata
Nellrsquoesempio a seguito la porta dellunitagrave di controllo RDNET CONTROL 2 egrave collegata allingresso DATA INPUT di un AC 26N la cui uscita parallela DATA LINK egrave inviata allingresso del successivo AC26N Nellesempio [n] egrave un numero compreso tra 3 e 32 (limite massimo dei dispositivi da collegare ad una sotto rete)
RJ 45
|1|2|3|4|5|6|7|8|
La lunghezza complessiva del cavo CAT5 di una sotto rete NON puograve eccedere i 900 metri
Il connettore deve essere collegato come
1 ndash disponibile per altre funzioni (ad esempio audio +) 2 ndash disponibile per altre funzioni (ad esempio audio ndash)3 ndash disponibile per altre funzioni (ad esempio massa analogica)4 ndash massa digitale5 ndash massa digitale6 ndash disponibile per altre funzioni (ad esempio alimentazione)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
ACCENSIONEAllrsquo accensione del dispositivo si avvia lrsquoinizializzazione che dura alcuni secondi Sul display viene visualizzato il modello il logo e la barra avanzamento caricamento del programma
Al termine del processo di installazione sul display viene visualizzata la finestra del menugrave ldquoMetersrdquo Per conoscere le indicazioni nel dettaglio fare riferimento al paragrafo ldquoDESCRIZIONE FINESTRA MENUrsquo ldquoMetersrdquo
AC26N egrave pronto per lrsquoutilizzo
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquouso
Ma
nu
ale
drsquou
so
5
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquouso
Ma
nu
ale
drsquou
so
6
A B 1 2 3 4 5 6
CONFIGURAZIONE E VISUALIZZAZIONEPer accedere alla finestra del menugrave principale egrave necessario premere il tasto ldquoMENUrdquo ( ) posto sul frontale del dispositivo
ldquoESCrdquo ( ) Da una qualunque pagina del menu premendo il tasto si torna automaticamente alla schermata precedente
MENUrsquo PRINCIPALE
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
I menugrave presenti nel processore sono sei e mostrano eo configurano i parametri del sistemaI menugrave principali sono
Meters visualizzazione livelli degli ingressi e delle uscite visualizzazione programma utilizzato e stato mute rapido
Preset memorizzare salvare ed eliminare le configurazioni del sistema
Matrix selezionare le uscite in funzione del segnale in ingresso
Ch Job configurazione di ogni singolo canale
X-Over configurare le frequenza di taglio e i tipi di filtri per ogni singola uscita
Option assegnazione degli ingressi e delle uscite contrasto display la versione del firmware ingressi ed altre opzioni
I menugrave e le singole opzioni visualizzati possono essere selezionati ruotando la manopolaldquoFUNCTIONS SETECTORrdquo ( ) Per accedere allrsquointerno della selezione egrave necessario evidenziare il parametro desiderato e premere la manopola ldquoPush Enterrdquo ( |) Lo stesso procedimento deve essere adottato per selezionare eo modificare le opzioni alrsquointerno delle voci del menugrave stesso
DESCRIZIONE FINESTRA MENUrsquo ldquoMetersrdquoQuesta finestra permette di visualizzare le configurazioni e lo stato generale degli ingressi e delle uscite la versione del programma utilizzato il suo stato e come viene pilotato il sistema
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
7
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
8
a) CANALI INGRESSO E USCITAI connettori di ingresso ed uscita sono identificati utilizzando le medesime indicazioni presenti sulla serigrafia del retro del dispositivoCon segnali di ingresso digitali lrsquoindicazione ldquoArdquo e ldquoBrdquo corrispondono allrsquoingressoRuotando la manopola ldquoFUNCTIONS SELECTORrdquo [2] si scorrono in modo ciclico i canali ingresso uscita e indicazione di mute generale (d) il canale selezionato viene evidenziato
COMPRESSIONE SEGNALELa compressione del segnale viene visualizzata tramite lo scorrimento della barra di destra dallrsquoalto verso il basso
MUTE Ogni singolo canale puograve essere posto nelle condizione di mute Selezionare il canale e premere la manopola ldquoPush Enterrdquo [2] per confermare il cambiamento di stato Alla indicazione del canale verragrave sostituita la lettera ldquoMrdquo e la barra verragrave completamente evidenziataPer ripristinare il funzionamento normale ripetere le precedenti azioni descritte
c) BARRA LIVELLO SEGNALELrsquoindicazione del livello di ogni singolo canale viene segnalato tramite lo scorrimento delle barra di sinistra
d) MUTE GENERALEErsquo possibile mettere in mute tutti gli ingressi e le uscite contemporaneamente Ruotare la manopola ldquoFUNCTIONS SELECTORrdquo [2] selezionare la lettera ldquoMrdquoe premere la manopola ldquoPush Enterrdquo [2]Per ripristinare il funzionamento normale ripetere le precedenti azioni descritteIl mute generale ha la prioritagrave piugrave alta rispetto ai mute dei singoli canali
b) BARRA LIVELLO COMPRESSIONEMUTE CANALE
e) MODALITArsquo DI COMANDOViene visualizzato come egrave utilizzato eo a quali dispositivi egrave collegato lrsquo AC26N
Local = utilizzo stand-alone Nessuna connessione ad un dispositivo esterno
NET = collegato direttamente alla rete dedicate RDnet e al computer
USB = collegato direttamente ad un computer tramite cavo USB
f) INDICAZIONE STATO IMPOSTAZIONITramite questa indicazione viene visualizzato se il programma caricato egrave stato modificato in uno o piugrave parametri rispetto allrsquoultimo salvataggio
= programma originale
= programma con parametri modificati
g) PROGRAMMA IMPOSTATOIl numero indica il programma caricato ed utilizzato dal sistema riferito alla locazione di salvataggio Fare riferimento al menugrave di ldquoPresetrdquo per ulterioi dettagli
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
DESCRIZIONE FINESTRA MENUrsquo ldquoCh Jobrdquo
Questa finestra permette di visualizzare la configurazione di ogni singolo canale
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) CANALI INGRESSO E USCITAI connettori di ingresso ed uscita sono identificati utilizzando le medesime indicazioni presenti sulla serigrafia del retro del dispositivo
b) LIVELLO DEL SEGNALEIndica guadagno del segnale Laumento nella intensitagrave di un segnale egrave espresso in decibel (dB) Il parametro puograve essere selezionato da -8000dB a +2000dB con passi di 001dB Un aumento di 6dB egrave approssimativamente uguale al raddoppiamento in scala lineare del livello in tensione del segnaleCon un guadagno maggiore di 0dB viene amplificato il segnale mentre con un guadagno inferiore di 0dB viene attenuato il segnale
c) RITARDO DEL SEGNALE (DELAY)I segnale audio riprodotto puograve essere ritardato per permettere lrsquoallineamento acustico Questo compensa le diverse posizioni dei diffusori durante lrsquoinstallazione e la riproduzione sonora ed egrave espresso il mS Il parametro puograve essere selezionato da 00mS a 729mS con passo 01mSPer allineare un segnale audio egrave possibile utilizzare la seguente formula
Ritardo = (GAPx1000)344
Ritardo = ms (espresso in millisecondi)GAP = distanza del diffusore dal punto di riferimento (espresso in metri)
Velocitagrave del suono = 344ms
d) MUTEOgni singolo canale puograve essere posto nella condizione di mute Lo stesso comando puograve essere attivato nella finestra del menugrave laquometersraquo NB Il mute generale ha la prioritagrave piugrave alta rispetto ai mute dei singoli canali
e) FASEPermette la rotazione di fase di 180deg rispetto al segnale in ingressoQuesta rotazione permette lrsquoottimizzazione soprattutto delle basse frequenze nelle installazioni complesse
f) EQUALIZZAZIONEQuesto comando apre la finestra del menugrave dellrsquoequalizzazione del singolo canale Viene principalmente utilizzato per correggere una o piugrave frequenze che devono essere attenuate oppure aumentate
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
109
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
oLrsquo AC26N gestisce 12 filtri per ogni singolo canale di ingresso e uscita con tre diversi tipi configurazioni
Passano tutte le frequenze ma aumenta e diminuisce solo quelle attorno alla frequenza centrale per una determinata banda e un guadagno stabilito
- Equalizzatore high-shelf passa tutte le frequenze ma aumenta o attenua le frequenze sopra la frequenza di taglio selezionata per il guadagno indicato
- Equalizzatore low-shelf passa tutte le frequenze ma aumenta o attenua le frequenze inferiori alla frequenza selezionata per il guadagno indicato
- Equalizzatore PEQ (peaking equalizer) egrave ideale per identificare isolare e correggere solo una determinata gamma di frequenze
f Numerazione dei 12 filtri disponibili per quellrsquoingresso oppure uscita1
f Viene visualizzato il tipo di filtro2
Dis Disinserito (non presente)
PEQ Peaking equalizer
Sh H Filtro high-shelf
Sh L Filtro low-shelf
Esempi PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
NOTA BENEIl parametro Bw determina il campo di frequenze adiacenti alla frequenza impostata dove viene attivato il filtro maggiore egrave il valore Bw maggiore e egrave il campo di frequenze (1Bw=1 ottava)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONEQuesto comando apre la finestra del menugrave compressione del singolo canale
g ) Treshold1
Identifica la soglia dove inizia il rapporto di compressione Il valore di base 11
g ) Ratio2
Indica il rapporto di conversione tra il segnale in ingresso e quello in uscita
g ) Post Gain Attach Release Hold3
Questi dati sono in funzione del rapporto di conversione che si vuole ottenerePost Gain egrave il guadagno di uscitaAttack egrave il tempo di attacco Release egrave il tempo di rilascioHold il tempo di mantenimento
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
DESCRIZIONE FINESTRA MENUrsquo ldquoPresetrdquoQuesta finestra permette di memorizzare fino a 32 configurazioni nellrsquoAC26NLa ditta costruttrice fornisce il sistema con un programma impostato e salvato nella posizione ldquo0rdquo e non sovrascrivibile
032 Indica la locazione di salvataggio della configurazioneQuesto numero appare anche nella finestra ldquoMetersrdquo nella posizione (g) in qualsiasi momento il programma utilizzato puograve essere visualizzato dellrsquoutente
Empty Preset Ersquo il nome che viene associato al numero della locazione quando non egrave salvato nessun settaggio (vuoto)
Local preset Ersquo il nome che viene associato al numero di locazione quando viene salvata una configurazione NB = Ersquo possibile salvare un settaggio con il nome desiderato al max 16 lettere solo utilizzando lrsquointerfaccia tramite il computer
Selezionando un programma appare la seguente finestra
Viene indicato il nome del programma assegnatoPer intervenire sulla applicazione sono a disposizione 3 scelte possibili
Save Il programma viene salvato nella memoria dellrsquoAC 26N
Del Il programma viene cancellato
Load Il programma viene caricato e pronto per essere utilizzato
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
11
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
12
DESCRIZIONE FINESTRA MENUrsquo ldquoX-OverrdquoQuest a finestra permette di selezionare per ogni uscit a un filtro p assa basso un filtro p assa alto oppure tramite la combinazione di entrambe creare un filtro p assa bandaIl filtro presente egrave un Linkwitz-Riley dove egrave possibile selezionare la pendenza di 12dBoct 24dBoct oppure 48dBoct e la relativa frequenza di t aglio
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) CANALI USCITA
I connettori di uscita sono identificati utilizzando le medesime indicazioni presenti sulla serigrafia del retro del dispositivo
b) FILTRO CROSSOVERSelezionare il filtro a seconda delle necessitagrave Ersquo possibile selezionare
Dis Nessun filtro attivato
HP Filtro passa-alto lasciare passare solo la parte di segnale audio superiore alla frequenza di taglio
LP Filtro passa-basso lasciare passare solo la parte di segnale audio inferiore alla frequenza di taglio
Configurazione Filtro Passa basso Passa alto
Nessuna Dis Dis
Passa alto HP Dis
Passa basso Dis LP
Passa banda HP LP
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
c) PENDENZA DI ATTENUAZIONESelezionare la pendenza di attenuazione del segnale audio in base alla diminuzione che si desidera ottenere Piugrave elevata egrave la pendenza di attenuazione a paritagrave di frequenza di taglio maggiore egrave la selezione del segnale Ersquo possibile selezionare
12 corrisponde a 12dboct
24 corrisponde a 24dboct
48 corrisponde a 48dboct
d) FREQUENZA DI TAGLIOPermette drsquoimpostare la frequenza di passaggio delle sole frequenze inferiori (filtro passa-basso) o delle sole frequenze superiori (filtro passa-alto)La scelta del taglio egrave in funzione della riproduzione che si vuole ottenereLrsquounitagrave di misura utilizzata egrave Hz
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
DESCRIZIONE FINESTRA MENUrsquo ldquoMatrixrdquoPermette di selezionare per ogni uscita il segnale in ingresso da utilizzare come sorgente
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) CANALI USCITAIdentificazione del canale in uscita da impostare
b) IDENTIFICAZIONI INGRESSISelezionare il tipo di segnale da abbinare a ogni singola uscita in base alle proprie necessitagrave Ersquo possibile selezionare
In A Viene associato il segnale in ingresso laquoAraquo
In B Viene associato il segnale in ingresso laquoBraquo
In A+B Viene associato la somma algebrica dei due segnali in ingresso laquoAraquo e laquoBraquo
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
DESCRIZIONE FINESTRA MENUrsquo ldquoOptionrdquoPermette di visualizzare le impostazioni sistema come lrsquoassegnazione degli ingressi e delle uscite attenuazione il contrasto del display e la versione del firmware
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711
InA-B SrcQuesta opzione permette di impostare il tipo di segnale audio in ingresso
An In = segnali audio analogici (ingressi ldquoArdquo e ldquoBrdquo)
Dig In = segnali audio digitali (ingresso AESEBU)
DigOut SrcQuesta opzione permette di selezionare la sorgente audio che verragrave indirizzata sul connettore AESEBU OUT (uscita digitale)
An In = segnali audio presenti negli ingressi analogici
Dig In = segnali audio presenti sullrsquoingresso digitale
OUT 1-2 = segnali audio presenti sulle uscite 1 e 2
OUT 3-4 = segnali audio presenti sulle uscite 3 e 4
OUT 5-6 = segnali audio presenti sulle uscite 5 e 6
Input ModePermette di configurare gli ingressi
Indip = sono indipendenti ed autonomi non sono soggetti a vincoli di alcun genere tra di loro
Linked = sono uniti e funzionano in modalitagrave stereoI compressori i filtri i ritardi il volumesono identici per i due canali
13
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
14
Atten Pad
Indica come egrave impostato il selettore ldquo-6dBrdquo posto sul retro [rif 5] Ersquo necessario attivare questo selettore quando i livelli di ingresso analogici sono troppo elevati Il selettore viene attivato solo tramite il pulsante nel menugrave egrave solo una visualizzazione
0dB = selettore non attivatoI segnali di ingresso sono i medesimi della sorgente in ingresso
-6dB = selettore attivatoI segnali in ingresso vengono attenuati di -6dB dal processore interno
Contrast
Consente di regolare il contrasto del display LCD per compensare la differenza di luminositagrave con il luogo di installazione Una maggiore chiarezza del display permette di navigare allrsquointerno dei menugrave in modo corretto e veloceIl settaggio in uscita dalla ditta produttrice egrave 60
10 piugrave chiaro 60 piugrave scuro 100
Fw Vers
Indica la versione del firmware del processore
SPECIFICHE TECNICHE
PRESTAZIONI AUDIORisposta in frequenza +- 01dB (20 to 30kHz)Gamma dinamica 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsione 0002 (1kHz +4dBu)
PRESTAZIONI AUDIO DIGITALI Processore DSP 2856-bit Frequenza elaborazione dati 48KHzConvertitori analogici 24-bit BURR BROWNRitardo di propagazione 15msMemorizzazioni configurazioni 32 preset
CONTROLLI Diplay LCD graficoPulsantiComandi ESC - MENU - FUNCTIONS SELECTION
ENTER
INGRESSIUSCITEIngresso analogico ndeg2 x XLR (3 poli femmina)
Impedenza di ingresso gt10KOhmLivello massimo +21dBu senza PAD
+27dBu con PADUscita analogica ndeg6 x XLR (3 poli maschio)
Impedenza di uscita 50OhmLivello massimo +21dBu Tipo Bilanciato
Ingresso digitale ndeg1x XLR (3 poli femmina)Tipo SPDIF-AESEBU (AES3)
Uscita digitale ndeg1x XLR (3 poli maschio)Tipo conforme allo standard dellrsquoingresso
IngressiUscita RDnet ndeg2 x XLR RJ45 (cavo CAT 5)USB Tipo B
PARAMETRI CONTROLLO AUDIOGuadagno -80dB a +20dB passo 01dBRitardo
ingresso 0 a 729mS passo 01 mSuscita 0 a 340mS passo 01mS
Rotazione di fase 0deg - 180deg
COMPRESSIONESoglia -80dB a +20dB passo 01dBRapporto 11 a Inf1 passo 001Guadagno in uscita 0dB a 40dB passo 01dBTempo di attacco 1mS a 1000mS passo 01mSTempo di rilascio 1mS a 1000mS passo 01mSTempo di mantenimento 1mS a 1000mS passo 01mS
EQUALIZZATORI12 equalizzatori per ogni ingresso e uscitaTipo PEQ (parametrico) Hi-shelf Lo-sheft
Frequenza 20Hz a 20KHz passo 1HzGuadagno -30dB a +15dB passo 001dBBanda 005dB a 2dB passo 001dB (solo per PEQ)
FILTRI CROSSOVERFiltro Linkwitz Riley
Tipo HP Passa-AltoLP Passa-Basso
Pendenza 12dBoct - 24dBoct - 48dBoctFrequenza di taglio 5Hz a 20KHz passo 1Hz
ALIMENTAZIONE Full-range 100-240Vac 50-60HzDIMENSIONI 430482x43x130mm (LxHxD)PESO 19Kg
Note Specifiche soggette a variazioni senza preavviso
CLASSIFICAZIONE EMIIn accordo alle normative EN 55103 lapparato egrave progettato e idoneo allutilizzo in ambienti Elettromagnetici E3 o inferiori (E2 E1)
INTRODUCTIONAC26N is a digital sound processor for the management of audio systems designed for fixed and touring installations AC26N uses the most modern technology with 2856 bit processors and high performance 24 bits ADDA converters The functions available in the processor are input and output levels delay polarity 12 equalization bands for each input and output channel multiple crossover and high performance limiter The control resolution of the filters is 1Hz Inputs and outputs can be set according to many configurations to meet any need AC26N can be controlled in real time and each one of its parameters can be configured on the front panel and through a computer by means of an intuitive graphical interface accessible through the software DVA Network and a dedicated RDnet or USB network connectionThe CPU and DSP software update via PC allows to keep the device up to date It is possible to save and recall 32 preset configurations
Package Contents- AC26N - Operating manual- Software CD- Power cord
Characteristics- 2 Inputs and 6 Outputs with flexible routing- AESEBU addressable stereo inputs and outputs - 2856 bit DSP- BURR-BROWN high performance 24 bit AD converters- Frequency resolution of the filters 1 Hz - 12 parametric equalizers for each input and output- 2 crossover filters for each output with selectable slope 122448 dBoct- High performance DRC multi configuration for limitercompression configuration of
each input and output- Adjustable level in dB polarity and delay for each input and output- Firmware Update via PC- Graphic LCD Display- 32 pre-sets can be stored by the user- USB interface for configuration and control via computer- RDnet interface that allows to control up to 256 remote devices
PC
PC
RDNET hub(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FUNCTIONS FRONT PANEL
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
CONTROLS AND FUNCTIONS
1) DISPLAYThe graphic LCD display allows to view and edit the AC26N information without a computer The display contrast can be set within the main menu
2) ldquoFunctions Selectorrdquo and ldquoPush Enterrdquo KNOBThis control allows to move select and change the parameters within the displayed menusRotation of the knob (Function Selector)- it allows to browse the menu pages- it allows to change the selected parametersPush the knob (Push Enter)- it allows to selectconfirm the parameters
3) ESC button This control allows to exit the displayed menus or to return to the previous view
4) MENU button This control allows to directly access the main menu
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
En
glis
hE
nglis
hu
ser
man
ual
user
man
ual
16
user
man
ual
user
man
ual
Englis
hE
nglis
h
15
DVA USB Manager
The firmware of the amplifier module can be updated via the USB portTo make this update possible and simple a dedicated program has been developed
It is recommended to download DVA USB Manager free software directly from dB Technologies (wwwdbtechnologiescom) in the special section laquoSoftware amp Controllerraquo
DVA Network
The AC26N is equipped with proprietary network interface called RDNET for PC interface through a device (RDNET control)For this purpose a proprietary communication protocol has been developed for receiving and sending data this connection permits real-time monitoring of the diffuser parameters such as output power amplifier temperature limiter status etc It is also possible to select various equalizations or create new ones set the desired volume levels using the specific plug-in
It is recommended to download DVA Network free software directly from dB Technologies (wwwdbtechnologiescom) in the special section laquoSoftware amp Controllerraquo DOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
REAR PANEL CONNECTIONS
1586 75 141210 11 13 169 17
14) USB connectorThis USB connector (type B) allows to connect the processor to a compute to check and update the firmware via a dedicated program (DVA Network)
15) ldquoMAINSrdquo POWER CONNECTIONIt allows to connect the provided power cord
16) FUSE HOLDER ldquoFUSErdquoMain power supply fuse housing
17) ldquoPOWERrdquo MAIN SWITCHThis switch allows to switch on and off the device
PUSH
P SHU
SHPU
P SHU
PUSH
CONNECTIONS
Analog Audio ConnectionsBalanced connections allow to minimize the cable induced noise so cable can be longerSuch connections may be used both on inputs and outputsXLR connector must be cabled with pin 1 to ground pin 2 to hot (+) and pin 3 to cold (-) With shielded cables connect the shield to pin 1XLR-XLR e XLR-Jack 14(63 mm) connection cables can be used to connect the AC26N
12
3
Input
XLR - female
Pin 3 =NegativeCold-VE Phase
Pin 3 =NegativeCold-VE Phase
1 2
3
Output
XLR - Male
Pin 2 = PositiveHot+VE Phase
Pin 2 = PositiveHot+VE Phase
Pin 2 = PositiveHot+VE Phase
Pin 2 = PositiveHot+VE Phase
Pin 1 =ScreenGroundEarth
Pin 1 =ScreenGroundEarth
Pin 1 =ScreenGroundEarth
Pin 1 =ScreenGroundEarth
Ring
Sleeve
Tip = PositiveHot+VE Phase
Ring = NegativeCold-VE Phase
Sleeve=ScreenGroundEarth
Sleeve=ScreenGroundEarth
Tip
The unbalanced connections can also be used However the cable induced noise increases and cable length must not exceed 5 metersSuch connections may be used both on inputs and outputsUnbalanced connection may lower the level of the input signal up to 6dB in order to overcome this drawback connect pin 3 to ground although this can increase the noise
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
18
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
17
CONTROLS AND FUNCTIONS
5) -6dB SELECTORThis selector allows to reduce all the analog XLR [6] input levels by 6 dB at the same time to compensate for the high output levels on the mixers or other audio devices When the input signal level bar on the display [1] remains always at full scale this means that the input signal level is excessive and a -6 dB attenuation is recommendedIn the Option menu it is possible to check when the selector is activated
6) INPUT CONNECTORS ldquoArdquo AND ldquoBrdquoInputs balanced at line levelCapable to accept XLR male connectors
7) OUTPUT CONNECTORS ldquo1rdquo ldquo2rdquordquo 3rdquo ldquo4rdquo ldquo5rdquo AND ldquo6rdquoOutputs balanced at line level Capable to accept XLR famale connectors
Be careful to correctly connect each output to each speaker or amplifier according to the settings of each channels to avoid damages and malfunctions
ldquoAESEBUrdquo Section
8) INPUT CONNECTORIn addition to the analog audio inputs a SPDIF-AESEBU (AES3) digital audio input is also provided It can be selected via the setup menuSuch input requires a balanced connection trough an XLR connector with a 110 ohm twisted 3-wires cable
9) ldquoOUTrdquo OUTPUT CONNECTORThis connector allows to forward audio signals available at the digital or analog inputs or outputs The source must be set by means of the Option menuThe connection must comply with the same standard of the input [8]
RDNET Section
10) DATA INPUT CONNECTORData input RJ45 connector
11) ldquoDATA LINKrdquo OUTPUT CONNECTORRJ45 connector for data output used for serial link in cascade
12) ldquoONrdquo INDICATOR LIGHTThis green indicator turns on only when the AC26N has recognized the RDNET main unit and it is connected to it via computer
13) ldquoACTIVErdquo INDICATOR LIGHTThis yellow indicator flashes when data transmission between RDNET and the device is active
12
3
Input
XLR - female
1 2
3
Output
XLR - Male
Tip Gambo
Tip= Signal
Pin 3 = Link to Pin 1
Pin 3 = Link to Pin 1
Digital Audio Connections (AESEBU)AESEBU (AES3 protocol) is and a balanced input electrically insulated by means of a transformer It allows carrying two audio channels in a single two-wires shielded cable The cable characteristics are twisted 3 poles impedance 100 ohm shielded equipped with XLR connector (AES3 standard)
RDnetEach RDNet port on Control 2 and Control 8 can be connected to maximum 32 cascade-connected compatible devices In the example below the control unit RDNET CONTROL 2 port is connected to the DATA INPUT of an AC 26N whose parallel DATA LINK output is sent to the input of the next AC26N In the example [n] is a number between 3 and 32 (maximum limit for the devices connected to a sub-network)
RJ 45
|1|2|3|4|5|6|7|8|
The overall length of a CAT5 sub-network cable cannot exceed 900 meters
The connector must be connected as follows
1 - Available for other functions (for example audio +) 2 - Available for other functions (for example audio -)3 - Available for other functions (for example analog ground)4 - digital ground5 - digital ground6 - Available for other functions (for example power supply)7 - RS 485 A8 - RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
POWER ON
When the device is turned on the initialization procedure starts It lasts few seconds The display shows the device model the company logo and a program loading progress bar
At the end of the installation process the display shows the Meters menu For further details about the indications refer to the paragraph MENU DESCRIPTION - METERS
AC26N is now ready for use
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION AND DISPLAY
To access the main menu window press the MENU key located on the device front panelIn any page of the menu press the ESC button to return to the previous screen
MAIN MENU
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
There are six menus in the processor They show andor configure the system parametersThe main menus are
Meters Input and output levels display program in progress display quick muting
Preset Store save and delete the system configurations
Matrix Select the outputs according to the input signal
Ch Job Configuration of each individual channel
X-Over Configuration of the cut-off frequency and the types of filters for each output
Option Assignment of the inputs and outputs display contrast firmware version inputs and other options
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
20
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
19
The menus and the individual options displayed can be selected by rotating the knob ldquoFUNCTION SELECTORrdquo ( ) To access the selection highlight the desired parameter and press the ldquoPush Enterrdquo ( | ) knobThe same procedure should be adoptd to select andor change the options inside each menu entry
MENU DESCRIPTION - ldquoMetersrdquo
This window allows to view the configuration and the general conditions of the inputs and outputs the version of the program used the program status and how the system is driven
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) INPUT AND OUTPUT CHANNELSThe input and output connectors are identified by the same information provided on the screen printing located on the device rear sideWith digital input signals the indications A and B concern the inputBy rotating the knob FUNCTION SELECTOR [2] input channels output channels and general muting indications are cyclically scrolled (d) the selected channel is highlighted
b) BAR COMPRESSION LEVEL CHANNEL MUTING
SIGNAL COMPRESSIONSignal compression is displayed by the vertical scrolling (top to down) of the right bar
MUTE Each channel can be individually muted Select the channel and press the Push Enter knob [2] to confirm the change of status The indication of the channel will be replaced by the letter M and the bar will be completely highlightedTo restore normal operation repeat the actions described above
c) SIGNAL LEVEL BARThe level indication for each channel is provided by scrolling the left bar
d) GENERAL MUTINGIt is possible to mute all the inputs and outputs simultaneously Rotate the knob FUNCTION SELECTOR select the letter M and press the Push Enter knobTo restore normal operation repeat the actions described aboveThe general mute has the highest priority with respect to the muting of individual channels
e) CONTROL MODEIt shows how the AC26N is used andor to which devices it is connected
Local = stand-alone usage No connection to an external device
NET = directly connected to dedicated RDnet network and to computer
USB = directly connected to another computer via USB cable
f) SETTING STATUS INDICATIONThis indication shows if the loaded program was amended in one or more parameters with respect to the last saving operation
= original program
= program with modified parameters
g) SET PROGRAMThe number shows the program that is loaded and used by the system with reference to the saving position Refer to the ldquoPresetrdquo menu for further details
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
MENU DESCRIPTION - CH JOB
This window allows to view the configuration of each individual channel
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) INPUT AND OUTPUT CHANNELSThe input and output connectors are identified by the same information provided on the screen printing located on the device rear side
b) SIGNAL LEVELIt shows the signal gain The increased signal intensity is expressed in decibels (dB) Such parameter can be selected in the range from -8000 dB to +2000 dB in steps of 001 dB An increase of 6 dB is approximately equal to doubling - in a linear scale - the signal voltage levelIf the gain exceeds 0 dB the signal is amplified while if the gain is lower than 0 dB the signal is attenuated
c) SIGNAL DELAYThe reproduced audio signal may be delayed to perform an acoustic alignment This compensates for the different positions of the speakers during the installation and the sound reproduction it is expressed in ms The parameter can be selected in the range from 00 ms to 729 ms in steps of 01 msThe following formula can be used to align an audio signal
Delay = (GAPx1000)344
Delay = ms (in milliseconds)GAP = distance between speaker and reference point (in meters)Speed of sound = 344 ms
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
22
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
21
d) MUTEEach channel can be individually muted The same command can be activated in the Meters Menu
NOTE The general mute has the highest priority with respect to the muting of individual channels
e) PhaseIt performs a phase rotation of 180deg with respect to the input signalSuch phase rotation allows the optimization in special way for low frequencies in complex installations
M M
f) EQUALIZATIONThis control opens the menu controlling the single channel equalization It is mainly used to correct one or more frequencies that must be reduced or increased
The AC26N manages 12 filters for each individual channel input and output with three different kinds of configuration
- PEQ Equaliser (peaking equalizer) ideal to identify isolate and correct only a certain range of frequencies All frequencies pass only those around the centre frequency are increased and decreased for a given bandwidth and set gain
- High-shelf Equalizer All frequencies pass but frequencies above the selected cut-off frequency are increased or attenuated by the given gain
- Low-shelf Equalizer All frequencies pass but frequencies below the selected cut-off frequency are increased or attenuated by the given gain
f Numbering of the 12 available filters for the specific input or output1
f Displays the kind of filter2
Dis Switched off (not present)
PEQ Peaking equlizer
Sh H High-shelf Filter
Sh L Low-shelf Filter
Examples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
NOTE
The parameter Bw defines the range of frequencies close to the set frequency where the filter is activated the greater the value of Bw the wider is the frequencies range (1 Bw = 1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONThis control opens the menu controlling the compression for the single channel
g1) ThresholdIdentifies the starting threshold for the compression ratio Base value 11
g2) RatioIndicates the conversion ratio between input and output signal
g3) Post Gain Attach Release HoldThese data are in function of the conversion ratio to achieve Post Gain is the output gain Attack is the attack time Release is the release time Hold is the holding time
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
24
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
23
MENU DESCRIPTION - PRESET
This window allows to store up to 32 configurations in the AC26NThe manufacturer provides the system with a program set and saved in position 0 that is not possible to overwrite
032 Indicates the location where the configuration is savedThis number also appears in the window Meters in position (g) The program in use can be displayed at any time by the user
Empty Preset It is the name associated with the location number when no setting is saved (empty)
Local preset It is the name associated with the location number when a setting is saved NOTE = It is possible to save a setting with the desired name up to 16 letters only via the computer interface
When a program is selected the following window is displayed
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
The name of the assigned program is displayed3 possible choices are available when working on the application
Save The program is saved in the AC 26N memory
Del The program is deleted
Load The program is loaded and ready to be used
MENU DESCRIPTION - X-OVER
This window allows to select for each output a low pass filter a high pass filter or create a band-pass filter via the combination of bothThe available filter is a Linkwitz-Riley where it is possible to select slopes of 12 dBoct 24 dBoct or 48 dBoct and their cut-off frequency
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) OUTPUT CHANNELS
The output connectors are identified by the same information provided on the screen printing located on the device rear side
b) CROSSOVER FILTERSelect the filter according to needs It is possible to select
Dis No filter enabled
HP High-pass filter set it to allow only the part of audio signal above the cut-off frequency
LP Low-pass filter set to allow only the part of audio signal below the cut-off frequency
Filter configuration Low-pass High-pass
Nothing Dis Dis
High-pass HP Dis
Low-pass Dis LP
Band-pass HP LP
12dBoct
24dBoct
Hz
dB
48dBoct
12dBoct
24dBoct
frequency
frequency
frequency
frequency
Hz
dB
48dBoct
c) ATTENUATION SLOPESelect the attenuation slope of the audio signal on the basis of the desired attenuation The higher the attenuation slope at the same cut-off frequency the greater the signal selection It is possible to select
12 equal to 12 dBoct
24 equal to 24 dBoct
48 equal to 48 dBoct
d) CUT-OFF FREQUENCYTo set the passing frequency for the lower frequencies only (low-pass filter) or the higher frequencies only (high-pass filter)The choice of the cut-off depends on the desired sound reproductionThe unit of measurement used is Hz
Hz
Hz
dB
dB
Ga
inG
ain
Ga
inG
ain
f0
f0
0dB0dB
0dB
-6dB
-6dB
0dB
0dB
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
26
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
25
MENU DESCRIPTION - MATRIX
For each output it allows to select the input signal to use as the source
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) OUTPUT CHANNELSIdentification of the output channel to set
b) IDENTIFICATIONS OF THE INPUTSIt selects the type of signal to match each output as needed It is possible to select
In A Associated with the input signal ldquoArdquo
In B Associated with the input signal ldquoBrdquo
In A+B Associated with the algebraic sum of the two input signals ldquoArdquo and ldquoBrdquo
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
MENU DESCRIPTION - OPTION
Allows to display the system settings such as the allocation of the inputs and outputs attenuation display contrast and firmware version
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcThis option allows to set the type of input audio signal
An In = Analog audio signals (inputs A and B)
DigIn = Digital audio signals (AESEBU input)
DigOut SrcThis option allows to select the audio source that will be forwarded to the connector AESEBU OUT (digital output)
An In = Audio signals available at analog inputs
Dig In = Audio signals available at digital inputs
OUT 1-2 = Audio signals available on outputs 1 and 2
OUT 3-4 = Audio signals available on outputs 3 and 4
OUT 5-6 = Audio signals available on outputs 5 and 6
Input ModeIt allows to configure the inputs
Indip = They are independent not subject to constraints of any kind between them
Linked = They are connected and work in stereo mode Compressors filters delays volume are identical for the two channels
Atten PadIt shows how to set the -6 dB switch located on the rear side [Ref 5] It is necessary to activate this selector when the analog input levels are too high The selector can be activated only by means of the button the menu is for display only
0 dB = Selector not activated The input signals are the same as the input source
-6 dB = Selector activated The input signals are attenuated by -6 dB with reference to the inner
processor
ContrastAllows to adjust the LCD display contrast to compensate for the brightness difference at the installation sites Greater display brightness allows to navigate correctly and quickly within the menuThe manufacturer output setting is 60
10 More bright 60 More dark 100
Fw VersIt shows the processor firmware version
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
28
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
27
TECHINICAL SPECIFICATION
AUDIO PERFORMANCEFrequency Response +- 01dB (20 to 30kHz)Dynamic Range 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistortion 0002 (1kHz +4dBu)
DIGITAL AUDIO PERFORMANCE Processor DSP 2856-bit Data processing Frequency 24-bit BURR BROWNAnalog converters 24-bit BURR BROWNPropagation Delay 15msStoring configurations 32 preset
CONTROLS Display LCD graficoButtonsControls ESC - MENU - FUNCTIONS SELECTION
ENTERINPUTSOUTPUTSAnalog Input ndeg2 x XLR (3 pole female)
Input impedance gt10KOhmMaximum Level +21dBu senza PAD
+27dBu con PADAnalog Output ndeg6 x XLR (3 pole male)
Output impedance 50OhmMaximum Level +21dBu Type Balanced
Digital Input ndeg1x XLR (3 pole female)Type SPDIF-AESEBU (AES3)
Digital Output ndeg1x XLR (3 pole male)Type Compliant with the input standard
RDnet InputsOutput ndeg2 x XLR RJ45 (CAT 5 cable)USB Tipo B
SOUND CONTROL PARAMETERSGain -80dB a +20dB step 01dBDelay
Input 0 a 729mS step 01 mSOutput 0 a 340mS step 01mSPhase Rotation 0deg - 180deg
COMPRESSIONThreshold -80dB a +20dB step 01dBRatio 11 a Inf1 step 001Output gain 0dB a 40dB step 01dBAttack time 1mS a 1000mS step 01mSRelease time 1mS a 1000mS step 01mSHold time 1mS a 1000mS step 01mS
EQUALIZERS12 equalizers for each input and outputType PEQ (parametrico) Hi-shelf Lo-sheft
Frequency 20Hz a 20KHz step 1HzGain -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (only with PEQ)
CROSSOVER FILTERSFilter Linkwitz Riley
Type HP High-pass LP Low-pass
Slope 12dBoct - 24dBoct - 48dBoctCUT-OFF FREQUENCY 5Hz a 20KHz passo 1Hz
POWER SUPPLY Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)
1719x17x51 inch (WxHxD)WEIGHT 19Kg
(42 lbs)Note Specifications subject to change without notice
EMI CLASSIFICATIONAccording to the standards EN 55103 this equipment is designed and suitable to operate in E3 (or lower E2 E1) Electromagnetic environments
EINLEITUNG
Verpackungsinhalt
Eigenschaften
AC26N ist ein digitaler Audio-Prozessor fuumlr die Verwaltung von Audio-Systemen der fuumlr feste und mobile Installationen entwickelt wurde AC26N benutzt die modernste Technologie mit 2856 bit-Prozessoren und 24-bit-ADDA-Wandlern mit hoher Leistungsfaumlhigkeit Die verfuumlgbaren Funktionen des Prozessors sind Ein- und Ausgangsstufen Verzoumlgerung (delay) Polaritaumlt 12 Equalizer-Frequenzen fuumlr Ein- und Ausgangskanal viele Crossover-Wahlmoumlglichkeiten und Limiter mit hoher Leistung Die Filter-Kontrolle hat eine Aufloumlsung von 1 Hz Die Ein- und Ausgaumlnge koumlnnen mit unterschiedlichen Einstellungen geregelt werden um allen Anforderungen gerecht zu werden AC26N kann in Echtzeit kontrolliert werden und jeder Parameter kann am Frontpaneel und vom Computer mit intuitiver graphischer Schnittstelle mittels Software DVA Network zugaumlnglich und einer Netzverbindung RDnet oder uumlber USB eingestellt werdenDie SW-Aktualisierung fuumlr CPU und DSP uumlber PC erlaubt die Vorrichtung auf dem aktuellen Stand zu halten Man kann 32 vorgesehene Konfigurationen speichern und aufrufen
- AC26N - Bedienungsanleitung- Software-CD- Versorgungskabel
- 2 Ein- und 6 Ausgaumlnge mit flexibler Adressierung- Adressierbarer Stereo-Ein- und Ausgang AESEBU - DSP 2856-bit- AD-Wandler BURR BROWN 24-bit mit hoher Leistungsfaumlhigkeit- Aufloumlsungsfrequenz der Filter 1 Hz - 12 parametrische Equalizer fuumlr jeden Ein- und Ausgang- 2 Crossover-Filter fuumlr jeden Ausgang mit auswaumlhlbarer Neigung 122448dBoct- DRC Multikonfiguration mit hoher Leistungsfaumlhigkeit fuumlr die Konfiguration des
Limitersder Kompression jedes Ein- und Ausgangs- Einstellbare dB-Stufe Polaritaumlt und Verzoumlgerung (delay) fuumlr jeden Ein- und Ausgang- Firmware-Aktualisierung uumlber PC- Graphisches LCD-Display- 32 Voreinstellungen vom Benutzer einstellbar- USB-Schnittstelle fuumlr die Kontrolle und Konfiguration mit dem Computer- Schnittstelle RDnet welche erlaubt bis zu 256 fern liegende Vorrichtungen
zu kontrollieren
PC
PC
RDNET control(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FUNKTIONEN VORDERSEITE
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
BEDIENUNGEN UND FUNKTIONEN
1) DISPLAYDas graphische LCD-Display erlaubt die Informationen des AC26N ohne einen Computer zu benutzen anzuzeigen und zu editieren Der Kontrast kann im Hauptmenuuml eingestellt werden
2) DREHGRIFF Functions Selector UND Push EnterDiese Kontrolle erlaubt sich in den Menuumls auf dem Display zu bewegen und die Parameter auszuwaumlhlen und zu veraumlndernDrehung des Drehgriffes (Functions Selectors)- Man kann sich innerhalb der verschiedenen Menuumlseiten bewegen- Erlaubt die Veraumlnderung der ausgewaumlhlten ParameterDruck des Drehgriffes (Push Enter)- Erlaubt die AuswahlBestaumltigung der Parameter
3) Taste ldquoESCrdquo Diese Kontrolle erlaubt die angezeigten Menuumls zu verlassen oder zur vorherigen Anzeige zuruumlckzukehren
4) Taste ldquoMenuumlrdquo Diese Kontrolle erlaubt den direkten Zugang zum Hauptmenuuml
Deuts
chD
euts
chB
ed
ien
un
gsan
leit
un
gB
ed
ien
un
gsan
leit
un
g
29
Deuts
chD
euts
chB
ed
ien
un
gsan
leit
un
gB
ed
ien
un
gsan
leit
un
g
30
DVA USB Manager
Die Firmware des Verstaumlrkermoduls kann uumlber den USB-Anschluss aktualisiert werdenUm diesen Vorgang zu ermoumlglichen und zu vereinfachen wurde ein dediziertes Programm entwickelt das beim Hersteller angefordert und auf einen Computer installiert werden muss
Wir empfehlen die Software DVA USB Manager direkt von der Webseite dB Technologies (wwwdbtechnologiescom) im Abschnitt laquoSoftware amp Controllerraquo herunterzuladen
DVA Network
AC26N ist mit einer eigenen als RDNET bezeichneten Netzschnittstelle ausgestattet dank der es uumlber ein Interface (RDNET Control) an einen Computer angeschlossen werden koumlnnenHierzu wurde ein Kommunikationsprotokoll entwickelt mit dem die Daten empfangen und gesendet werden Dank dieser Verbindung koumlnnen die Lautsprecherparameter wie Ausgangsleistung Verstaumlrkertemperatur Limiterstatus usw in Echtzeit kontrolliert werden Auszligerdem koumlnnen verschiedene Entzerrungen ausgewaumlhlt bzw neue erstellt werden oder die gewuumlnschte Lautstaumlrke eingestellt werden
Wir empfehlen die Software DVA_Network direkt von der Webseite dB Technologies (wwwdbtechnologiescom) im Abschnitt laquoSoftware amp Controllerraquo herunterzuladenDOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
RUumlCKWANDANSCHLUumlSSE
1586 75 141210 11 13 169 17
14) USB-SteckverbinderDieser USB-Steckverbinder (Typ B) erlaubt den Prozessor an einem Computer anzuschlieszligen um die Firmware mit dem speziellen Programm (DVA Network) zu kontrollieren und zu aktualisieren
15) STROMANSCHLUSS MAINSErlaubt den Anschluss des mitgelieferten Versorgungskabels
16) SICHERUNGSTRAumlGER FUSEAufnahme fuumlr die Netz-Sicherung
17) HAUPTSCHALTER POWERDer Schalter erlaubt das Aus- und Einschalten des Audio-Controllers
BEDIENUNGEN UND FUNKTIONEN
5) WAHLSCHALTER -6dBDer Wahlschalter erlaubt das Level des analogen Eingangs XLR [6] um 6 dB zu verringern und gleichzeitig das hohe Ausgangslevel der Mixer oder anderer Audio-Vorrichtungen auszugleichen Wenn der Balken des Signallevels der Eingaumlnge auf dem Display [1] immer auf Maximum steht zeigt dies an dass das Signallevel am Eingang hoch ist und es wird empfohlen die Daumlmpfung -6dB zu benutzenIm Menuuml Option ist es moumlglich zu kontrollieren ob der Wahlschalter aktiviert ist
6) STECKVERBINDER AM EINGANG A UND BAuf Leitungslinie ausgeglichene EingaumlngeSie koumlnnen auch XLR-Steckdosen aufnehmen
7) AUSGANG-STECKVERBINDER ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo UND ldquo6rdquoAuf Leitungslinie ausgeglichene Ausgaumlnge Sie koumlnnen auch XLR-Stecker aufnehmen
Darauf achten dass die Ausgaumlnge korrekt entsprechend der Einstellungen der einzelnen Kanaumlle an den Lautsprechern oder Verstaumlrkern angeschlossen sind um Schaumlden und Fehlfunktionen vorzubeugen
Abschnitt ldquoAESEBUrdquo
8) EINGANGS-STECKVERBINDER INZusaumltzlich zu den analogen Audio-Eingaumlngen wurde ein digitaler Audio-Eingang SPDIF-AESEBU (AES3) vorgesehen der uumlber das Setup-Menuuml ausgewaumlhlt werden kannDer Eingang erfordert einen ausgeglichenen Anschluss mit einem XLR-Steckverbinder mit einem verdrillten Kabel mit 3 Leitern von 110 Ohm
9) AUSGANGS-STECKVERBINDER OUTDieser Steckverbinder erlaubt das Audiosignal an den analogen oder digitalen Eingaumlngen oder Ausgaumlngen zu verteilen Die Quelle muss uumlber das Menuuml Option eingestellt werdenDer Anschluss muss demselben Standard des Eingang entsprechen [Ref 8]
Abschnitt ldquoRDNETrdquo
10) EINGANGS-STECKVERBINDER DATA INPUTSteckverbinder RJ45 fuumlr den Dateneingang
11) AUSGANGS-STECKVERBINDER DATA LINKSteckverbinder RJ45 fuumlr den Datenausgang Fuumlr die serielle Kaskaden-Verbindung
12) LEUCHTANZEIGE ONDiese gruumlne Anzeige leuchtet nur wenn AC26N uumlber den Computer mit der Haupteinheit RDNET verbunden ist und diese erkannt hat
13) LEUCHTANZEIGE ACTIVEDiese gelbe Anzeige blinkt wenn eine Datenuumlbertragung zwischen RDNET und der Vorrichtung aktiv ist
PUSH
P SHU
SHPU
P SHU
PUSH
ANSCHLUumlSSE
Analoge Audio-AnschluumlsseDie ausgeglichenen Anschluumlsse erlauben die Geraumlusche der Kabel auf ein Minimum zu verringern und so die Benutzung langer Kabel zuzulassenDiese Anschluumlsse koumlnnen sowohl an den Ein- als auch an den Ausgaumlngen benutzt werdenDer XLR-Steckverbinder muss mit Pin 1 an Masse Pin 2 am Pluspol (+) und Pin 3 am Minuspol (-) angeschlossen werden Bei einem abgeschirmten Kabel muss die Abschirmung an Pin 1 liegenDie Verbindungskabel XLR-XLR und XLR-Jack 14 (63 mm) koumlnnen fuumlr den Anschluss
12
3
Eingang
XLR weiblichen
Pin 3 = MinuspolErkaumlltungphase -VE
Pin 3 = MinuspolErkaumlltungphase -VE
1 2
3
Ausgang
XLR maumlnnlichen
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Ring
Schaft
Spitze = PluspolWaumlrmephase +VE
Ring = MinuspolErkaumlltungphase -VE
Schaft=SchirmMasse
Spitze
Die nicht ausgeglichenen Anschluumlsse koumlnnen auch benutzt werden wenn die Kabelgeraumlusche ansteigen und diese Kabel duumlrfen nicht laumlnger sein als 5 MeterDiese Anschluumlsse koumlnnen sowohl an den Ein- als auch an den Ausgaumlngen benutzt werdenDie nicht ausgeglichenen Anschluumlsse koumlnnen das Signallevel am Eingang um 6 dB verringern um dem vorzubeugen muss Pin 3 an Masse angeschlossen werden obwohl dies das Geraumlusch verstaumlrken kann
12
3
Eingang
XLR weiblichen
1 2
3
Ausgang
XLR maumlnnlichen
Spitze Schaft
Spitze = Signal
Schaft=SchirmMasse
Pin 3 = zu Pin 1 gebruumlckt
Pin 3 = zu Pin 1 gebruumlckt
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
31
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
32
Digitales Audio (AESEBU)AESEBU (Protokoll AES3) ist ein ausgeglichener und uumlber einen Transformator elektrisch isolierter Eingang Er erlaubt die Benutzung von zwei Kanaumllen an einem einzigen abgeschirmten bipolaren Kabel Das gedrillte Kabel muss 3-polig sein eine Impedanz von 100 Ohm haben und mit einem XLR-Steckverbinder (AES3 Standard) abgeschirmt sein
RdnetJeder Port RDNet an Control 2 und Control 8 kann an max 32 kompatiblen Vorrichtungen die in Kaskade geschaltet sind angeschlossen werden Im nachstehenden Beispiel ist der Port der Kontrolleinheit RDNET CONTROL 2 am Eingang DATA INPUT eines AC 26N angeschlossen dessen paralleler Ausgang DATA LINK zum Eingang des naumlchsten AC26N geht Im Beispiel ist [n] eine Nummer zwischen 3 und 32 (maximale Anzahl der anschlieszligbaren Vorrichtungen an nur einem Netz)
RJ 45
|1|2|3|4|5|6|7|8|
Die Gesamtlaumlnge des Kabels CAT5 eines Unternetzes kann NICHT laumlnger als 900 Meter sein
Der Steckverbinder muss wie folgt angeschlossen sein1 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio +) 2 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio -)3 ndash Verfuumlgbar fuumlr andere Funktionen (zB analoge Masse)4 ndash digitale Masse5 ndash digitale Masse6 ndash Verfuumlgbar fuumlr andere Funktionen (zB Versorgung)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
EINSCHALTEN
Beim Einschalten der Vorrichtung startet die Initialisierung die einige Sekunden lang dauert Auf dem Display wird das Modell das Logo und der Fortschrittsbalken der Ladung des Programms angezeigt
Nach der Initialisierung erscheint auf dem Display das Menuumlfenster Meters Um die Angaben im Detail zu erfahren beziehen Sie sich bitte auf das Kapitel BESCHREIBUNG DES MENUumlFENSTERS Meters
AC26N kann jetzt benutzt werden
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
MENUrsquo PRINCIPALE
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Die sechs Menuumls im Prozessor zeigen undoder konfigurieren die Systemparameter
Anzeige der Levels der Ein- und Ausgaumlnge Anzeige des benutzten Programms und dessen Status Mute schnell
Speicherung Speicherung und Eliminierung der Systemkonfigurationen
Auswahl der Ausgaumlnge je nach Eingangssignal
Konfiguration jedes einzelnen Kanals
Konfiguration der Schnittfrequenzen und der Filtertypen fuumlr jeden einzelnen Ausgang
Zuordnung der Ein- und Ausgaumlnge Kontrast des Displays Firmware-Version Eingaumlnge und andere Optionen
Das Menuuml und die einzelnen Optionen der Anzeige koumlnnen durch Drehen des Drehgriffes FUNKTIONS SELECTOR ( ) ausgewaumlhlt werden
Die Hauptmenuumls sind
Meters
Preset
Matrix
Ch Job
X-Over
Option
Um die Auswahl zu treffen muss der gewuumlnschte Parameter auswaumlhlt und der Drehgriff Push Enter( | ) gedruumlckt werdenDas selbe Verfahren muss fuumlr die Auswahl undoder die Aumlnderung der Optionen innerhalb der Menuumlpunkte angewendet werden
BESCHREIBUNG DES MENUumlFENSTERS Meters
Diese Seite erlaubt die Konfigurationen und den allgemeinen Status der Ein- und Ausgaumlnge der benutzten Programmversion dessen Status und die Steuerung des Systems anzuzeigen
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
KONFIGURATION UND ANZEIGE
Um in das Fenster des Hauptmenuumls zu gelangen muss die Taste Menuuml ( ) auf der Frontseite der Vorrichtung gedruumlckt werdenMit der Taste ESC ( ) kehrt man von jeder Seite des Menuumls auf die vorherige Seite zuruumlck
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
33
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
34
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziertBei den digitalen Eingangssignalen entspricht die Angabe A und B dem EingangDreht man den Drehgriff FUNCTIONS SELECTOR [2] durchlaumluft man zyklisch die Ein- und Ausgangskanaumlle und die Angabe Mute allgemein (d) der ausgewaumlhlte Kanal wird hervorgehoben
b) BALKEN FUumlR DAS KOMPRESIONSLEVELMUTE KANAL
SIGNALKOMPRESSIONDie Signalkompression wird durch das Gleiten des rechten Balkens von oben nach unten angezeigt
MUTE Jeder einzelne Kanal kann auf Mute gestellt werden Den Kanal auswaumlhlen und den Drehgriff Push Enter [2] druumlcken um die Aumlnderung des Status zu bestaumltigen Die Angabe des Kanals wird durch den Buchstaben M ersetzt und der Balken wird komplett hervorgehobenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werden
c) BALKEN DES SIGNALLEVELSDie Anzeige des Levels jedes einzelnen Kanals wird durch das Gleiten des linken Balkens angezeigt
d) MUTE ALLGEMEINEs ist moumlglich alle Ein- und Ausgaumlnge gleichzeitig auf Mute zu schalten Den Drehgriff FUNCTIONS SELECTOR drehen den Buchstaben M waumlhlen und dann den Drehgriff Push Enter druumlckenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werdenDie allgemeine Stummschaltung hat eine houmlhere Prioritaumlt als die Stummschaltung der einzelnen Kanaumlle
e) ANSTEUERUNGSARTENEs wird angezeigt wie AC26N benutzt wird undoder an welchen Vorrichtungen es angeschlossen ist
= Benutzung stand-alone Kein Anschluss an einer externen Vorrichtung
= Direkt am Netz RDnet und am Computer angeschlossen
= Uumlber USB-Kabel direkt am Computer angeschlossen
f) ANZEIGE DES STATUS DER EINSTELLUNGENHier wird angezeigt ob einer oder mehrere Parameter des geladenen Programms im Vergleich zur letzten Speicherung veraumlndert wurden
Original-Programm
Programm mit veraumlnderten Parametern
g) EINGESTELLTES PROGRAMMDie Nummer zeigt das vom System geladene und benutzte Programm in Bezug auf die Lokalisierung der Speicherung an Fuumlr weitere Details beziehen Sie sich bitte auf das Menuuml Preset
Local
NET
USB
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
BESCHREIBUNG DES MENUumlFENSTERS Ch Job
Dieses Fenster erlaubt die Anzeige der Konfiguration jedes einzelnen Kanals
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) SIGNALLEVELZeigt die Signalstaumlrke an Das Ansteigen der Signalintensitaumlt wird in Dezibel (dB) ausgedruumlckt Der Parameter kann zwischen -8000 dB und +2000 dB in Schritten von 001 dB ausgewaumlhlt werden Ein Anstieg von 6 dB ist fast gleich eine Verdoppelung in linearer Skala des Spannungswertes des SignalsBei einer Staumlrke von 0 dB wird das Signal verstaumlrkt waumlhrend es ein einer Staumlrke von weniger als 0 dB abgeschwaumlcht wird
c) VERZOumlGERUNG DES SIGNALS (DELAY)Das wiedergegebene Audio-Signal kann verzoumlgert werden um die akustische Ausrichtung zu erlauben Dies gleicht die verschiedenen Positionen der Lautsprecher bei der Installation und Klangwiedergabe aus und wird in mS ausgedruumlckt Der Parameter kann zwischen 00 mS und 729 mS in Schritten von 01mS ausgewaumlhlt werden
Um ein Audiosignal auszurichten kann folgende Formel benutzt werden
Verzoumlgerung = GAPx1000)344
Verzoumlgerung = mS (in Millisekunden ausgedruumlckt)GAP = Abstand des Lautsprechers vom Referenzpunkt (in Metern ausgedruumlckt)Klanggeschwindigkeit = 344 ms
d) MUTEJeder einzelne Kanal kann auf Mute gestellt werden Derselbe Befehl kann im Fenster des Menuumls Meters aktiviert werden PS Die al lgemeine Stummschaltung hat eine houmlhere Priori taumlt als die Stummschaltung der einzelnen Kanaumlle
e) PHASEErlaubt die Phasenrotation um 180deg zum EingangssignalDiese Rotation erlaubt vor Allem die Optimierung der niederen Frequenzen bei komplexen Installationen
f) ENTZERRUNGENDieser Befehl oumlffnet das Menuumlfenster fuumlr die Entzerrung des einzelnen Kanals Er wird vor Allem benutzt um eine oder mehrere Frequenzen zu korrigieren die gedaumlmpft oder verstaumlrkt werden muumlssen
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
35
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
36
AC26N verwaltet 12 Filter fuumlr jeden einzelnen Ein- und Ausgangskanal mit drei verschiedenen Konfigurationen- Equalizer PEQ (peaking equalizer) ist ideal um nur ein bestimmtes Frequenzband
zu identifizieren zu isolieren und zu korrigieren Es gehen alle Frequenzen durch aber nur die um die mittlere Frequenz steigt und sinkt um eine bestimmte Bandbreite und eine bestimmte Staumlrke
- Equalizer High-Shelf geht alle Frequenzen durch aber die Frequenzen uumlber der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
- Equalizer Low-Shelf geht alle Frequenzen durch aber die Frequenzen unter der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
f Nummerierung der 12 verfuumlgbaren Filter fuumlr diesen Ein- oder Ausgang1
f2 Es wird der Filtertyp angezeigt
Dis Ausgeschaltet (nicht vorhanden)
PEQ Peaking equalizer
Sh H Filter High-Shelf
Sh L Filter Low-shelf
Beispiele PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
ANMERKUNGDer Parameter Bw legt das Frequenzfeld neben der eingestellten Frequenz fest wo der Filter aktiviert wird je houmlher der Bw-Wert desto houmlher das Frequenzfeld (1Bw=1 Oktave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filter High-Shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filter Low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) KOMPRESSIONDieser Befehl oumlffnet das Menuumlfenster fuumlr die Kompression des einzelnen Kanals
g1) TresholdIdentifiziert die Schwelle an der das Kompressionsverhaumlltnis beginnt Der Basiswert 11
g2) RatioIdentifiziert das Kompressionsverhaumlltnis zwischen dem Ein- und Ausgangssignal
g3) Post Gain Attach Release HoldDiese Daten entsprechen dem Kompressionsverhaumlltnis das man erreichen moumlchte
Post Gain ist der Gewinn am AusgangAttack ist die Anschlusszeit Release ist die ReleasezeitHold ist die Beibehaltungszeit
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
BESCHREIBUNG DES MENUumlFENSTERS Preset
Dieses Fenster erlaubt bis zu 32 Konfigurationen im AC26N zu speichernDer Hersteller liefert das System mit einem voreingestellten Programm das auf Position 0 gespeichert ist und nicht uumlberschrieben werden kann
032 Es zeigt die Lokalisierung der Speicherung der KonfigurationDiese Nummer erscheint auch im Fenster Meters auf der Position (g) Das benutzte Programm kann jederzeit vom Benutzer angezeigt werden
Empty Preset Es ist der Name der der Nummer der Lokalisierung zugeordnet wird wenn keine Einstellung gespeichert ist (leer)
Local preset Es i s t de r Name de r de r Nummer de r Loka l i s i e rung zugeordnet wird wenn eine Konfiguration gespeichert wird
ANMERKUNG = Man kann eine Einstellung mit dem gewuumlnschten Namen mit max 16 Buchstaben nur speichern wenn man die Schnittstelle uumlber den Computer benutzt
Bei der Wahl eines Programms erscheint folgendes Fenster
Anzeige des Namens der dem Programm zugeordnet istUm auf die Anwendung einzuwirken stehen 3 Auswahlmoumlglichkeiten zur Verfuumlgung
Das Programm wird im Speicher des AC 26N gespeichert
Das Programm wird geloumlscht
Das Programm wird geladen und ist bereit fuumlr die Benutzung
Save
Del
Load
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
37
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
38
BESCHREIBUNG DES MENUumlFENSTERS X-Over
Dieses Fenster erlaubt fuumlr jeden Ausgang einen Bassdurchgangsfilter einen Hochdurchgangsfilter oder mittels Kombination von beiden einen Banduumlbergangsfilter zu waumlhlenDer Filter ist ein Linkwitz-Riley wo man die Neigung von 12 dBoct 24dBoct oder 48 dBoct und die entsprechende Schnittfrequenz auswaumlhlen kann
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) AUSGANGSKANAumlLE
Die Steckverbinder am Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) FILTER CROSSOVERDen Filter nach Bedarf waumlhlen Man kann folgendes auswaumlhlen
Dis Kein Filter aktiviert
HP Hochdurchgangsfilter nur den Teil des Audiosignals durchlassen der uumlber der Schnittfrequenz liegt
LP Bassdurchgangsfilter nur den Teil des Audiosignals durchlassen der unter der Schnittfrequenz liegt
Filter-Konfiguration Tiefpass Hochpass
Nichts Dis Dis
Hochpass HP Dis
Tiefpass Dis LP
Bandpass HP LP
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
c) DAumlMPFUNGSNEIGUNGDie Daumlmpfungsneigung des Audiosignals auf der Basis der Verringerung auswaumlhlen die man erreichen moumlchte Je houmlher die Daumlmpfungsneigung bei gleicher Schnittfrequenz desto groumlszliger ist die Signalauswahl Man kann folgendes waumlhlen
12 entsprechend 12 dboct
24 entsprechend 24 dboct
48 entsprechend 48 dboct
d) SCHNITTFREQUENZErlaubt die Durchgangsfrequenz der niederen Frequenzen (Bassdurchgangsfilter) oder der hohen Frequenzen (Hochdruchgangsfilter) einzustellenDie Auswahl des Schnitts bezieht sich auf die Wiedergabe die man erreichen moumlchteDie benutzte Maszligeinheit ist Hz
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
BESCHREIBUNG DES MENUumlFENSTERS Matrix
Erlaubt fuumlr jeden Ausgang das Eingangssignal zu waumlhlen das als Quelle benutzt werden soll
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) AUSGANGSKANAumlLEIdentifizierung des einzustellenden Ausgangskanals
b) IDENTIFIZIERUNG DER EINGAumlNGEDen Signaltyp auswaumlhlen der nach eigener Anforderung jedem einzelnen Ausgang zugeordnet werden soll Man kann folgendes waumlhlen
In A Das Signal wird dem Eingang A zugeordnet
In B Das Signal wird dem Eingang B zugeordnet
In A+B Zuordnung der a lgebra ischen Summe der be iden Eingangssignale A und B
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
BESCHREIBUNG DES MENUumlFENSTERS Option
Erlaubt die Anzeige der Systemeinstellungen wie die Zuordnung der Ein- und Ausgaumlnge Daumlmpfung Displaykontrast und Firmware-Version
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B Src
Diese Option erlaubt die Einstellung des Audio-Signaltyps am Eingang
Analoge Audiosignale (Eingaumlnge A und B)
Digitale Audiosignale (Eingang AESEBU)
DigOut Src
An In =Audiosignale an den analogen Eingaumlngen
Dig In =Audiosignale am digitalen Eingang
OUT 1-2 =Audiosignale an den Ausgaumlngen 1 und 2
OUT 3-4 =Audiosignale an den Ausgaumlngen 3 und 4
OUT 5-6 =Audiosignale an den Ausgaumlngen 5 und 6
Input Mode
An In
Dig In
Indip =
Linked =
Diese Option erlaubt die Audioquelle zu waumlhlen die fuumlr den Steckverbinder AESEBU OUT (digitaler Ausgang) bestimmt ist
Erlaubt die Eingaumlnge zu konfigurieren
Sie sind unabhaumlngig und selbststaumlndig sie unterliegen keinen Verpflichtungen untereinander Sie sind verbunden und funktionieren im Stereo-Modus
Die Kompressoren Filter Verzoumlgerungen die Lautstaumlrke sind bei beiden Kanaumllen identisch
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
39
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
40
Atten PadZeigt an wie der Wahlschalter -6 dB auf der Ruumlckseite eingestellt ist [Ref 5] Dieser Wahlschalter muss aktiviert werden wenn das Level an den analogen Eingaumlngen zu hoch ist Der Wahlschalter wird uumlber die Taste aktiviert im Menuuml gibt es nur eine Anzeige
0dB = Wahlschalter nicht aktiviert
-6dB = Wahlschalter aktiviert
Contrast
10 heller 60 dunkler 100
Fw Vers
Die Eingangssignale sind dieselben wie die Eingangsquelle
Die Eingangssignale werden vom internen Prozessor um -6 dB gedaumlmpft
Erlaubt den Kontrast des LCD-Displays einzustellen um den Unterschied der Helligkeit auf den Installationsort auszurichten Ein deutlicheres Display erlaubt auf korrekte und schnelle Weise innerhalb der Menuumls zu surfenDie Hersteller-Einstellung am Ausgang liegt bei 60
Zeigt die Firmware-Version des Prozessors an
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
41
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
42
TECHNISCHE DATEN
Antwort in FrequenzDynamische GammaCMMRCrosstalkDistorsion
ProzessorFrequenz der DatenausarbeitungAnaloge Converter Verzoumlgerung der VerteilungSpeicherung der Konfigurationen
DisplayTastenBedienungen
Analoger Eingang ndeg2 x XLR (3-poliger Female Stecker)Impedanz des Eingangs gt10KOhmMaximales Level +21dBu ohne PAD
+27dBu bei PAD
Impedanz des Ausgangs 50OhmMaximales Level +21dBu Typ symmetrisch
Typ SPDIF-AESEBU (AES3)
Typ Entsprechend dem Standard des Eingang
Typ
Typ
NETZSPANNUNGABMESSUNGEN (BXHXT)GEWICHT
AUDIO-LEISTUNGEN+- 01dB (20 to 30kHz)116dB typgt 60dB (50 to 10kHz)lt -100dB0002 (1kHz +4dBu)
DIGITALE AUDIO-LEISTUNGEN DSP 2856-bit 48KHz24-bit BURR BROWN15ms32 preset
KONTROLLEN LCD GrafikESC - MENU - FUNCTIONS SELECTIONENTER
EIN-AUSGAumlNGE
Analoger Ausgang ndeg6 x XLR (3-poliger Male Stecker)
Digitaler Eingang ndeg1x XLR (3-poliger female Stecker)
Digitaler Ausgang ndeg1x XLR (3-poliger Male Stecker)
Ein-Ausgang Rdnet ndeg2 x XLR RJ45 (kabel CAT 5) USB Typ B
KONTROLLPARAMETER AUDIOStaumlrke -80dB a +20dB step 01dBVerzoumlgerung Eingang 0 a 729mS step 01 mS
Ausgang 0 a 340mS step 01mSPhasenrotation 0deg - 180deg
KOMPRESSIONSchwelle -80dB a +20dB step 01dBVerhaumlltnis 11 a Inf1 step 001Staumlrke am Ausgang 0dB a 40dB step 01dBAnschlusszeit 1mS a 1000mS step 01mSReleasezeit 1mS a 1000mS step 01mSBeibehaltungszeit 1mS a 1000mS step 01mS
EQUALIZER12 Equalizer fuumlr jeden Ein- und Ausgang
PEQ (parametrischer) Hi-shelf Lo-sheftFrequenz 20Hz a 20KHz step 1HzStaumlrke -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (lediglich PEQ)
FILTER CROSSOVERFilter Linkwitz Riley
HP HochdurchgangsfilterLP Bassdurchgangsfilter
Neigung 12dBoct - 24dBoct - 48dBoctSchnittfrequenz 5Hz a 20KHz step 1Hz
Full-range 100-240Vac 50-60Hz430482x43x130mm 19Kg
AnmerkungenSpezifikationen unterliegen Aumlnderungen ohne Vorankuumlndigung
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
INTRODUCTIONAC26N est un processeur audio numeacuterique pour la gestion de leacutequipement audio conccedilu pour des installations fixes et mobiles Il fonctionne selon une technologie de pointe avec des processeurs agrave 2856bits et des convertisseurs ADDA agrave 24-bits hautes performances Les fonctions du processeur sont les niveaux dentreacutee et de sortie le deacutelai (delay) la polariteacute 12 bandes deacutegalisation par canal dentreacutee et de sortie diffeacuterentes seacutelections de croisement (crossover) et un limiteur hautes performances Le controcircle des filtres a une reacutesolution de 1Hz Les entreacutees et les sorties peuvent ecirctre programmeacutees en plusieurs configurations pour satisfaire tous les besoins AC26N peut ecirctre controcircleacute en temps reacuteel et tous les paramegravetres peuvent ecirctre configureacutes depuis le pupitre frontale et par ordinateur avec interface graphique intuitive accessible via le logiciel laquoDVA Networkraquo et une connexion de reacuteseau deacutedieacutee RDnet ou USBLa mise agrave jour du logiciel pour lUniteacute centrale et DSP par ordinateur portable permet de maintenir le dispositif actualiseacute Il est possible denregistrer et de rappeler 32 configurations preacute-eacutequipeacutees de configuration
Contenu de lemballage - AC26N - Mode demploi- CD logiciel- Cacircble dalimentation
Caracteacuteristiques- 2 entreacutees et 6 sorties avec adressage flexible- Entreacutee et sortie steacutereacuteo AESEBU adressables - DSP 2856-bit- Convertisseurs AD BURR BWOWN 24-bit hautes performances- Freacutequence de reacutesolution des filtres 1 Hz - 12 eacutegaliseurs parameacutetriques pour chaque entreacutee et sortie- 2 filtres de croisement par sortie avec pente seacutelectionnable agrave 122448dBoct- DRC agrave configuration multiple hautes performances pour configuration limiteur
compression pour chaque entreacutee et sortie- Niveau reacuteglable en dB polariteacute et deacutelai pour chaque entreacutee et sortie- Mise agrave jour du micrologiciel par lordinateur- Affichage graphique agrave cristaux liquides- 32 preacutereacuteglages enregistrables par lutilisateur- Interface USB pour le controcircle et la configuration par ordinateur- Interface RDnet permettant de controcircler jusquagrave 256 dispositifs agrave distance
PC
PC
RDNETcontrol(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FONCTIONS DE LA FACE AVANT
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
COMMANDES ET FONCTIONS1) AFFICHAGE
Laffichage graphique agrave cristaux liquides permet de visualiser et deacutediter les informations de lAC26N sans utiliser lordinateur Le contraste peut ecirctre configureacute dans le menu principal
2) MANETTE Functions Selector et Push EnterCe controcircle permet de se deacuteplacer de seacutelectionner et de modifier les paramegravetres dans les menus affichables agrave leacutecranRotation de la manette (Functions Selectors)- permet de se deacuteplacer sur les diffeacuterentes pages du menu - permet de modifier les paramegravetres seacutelectionneacutesPression de la manette (Push Enter)- permet de seacutelectionnervalider les paramegravetres
3) Bouton ESC Ce controcircle permet de quitter les menus afficheacutes ou de revenir agrave la visualisation preacuteceacutedente
4) Bouton Menu Ce controcircle permet dacceacuteder directement au menu principal
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
Fra
nccedilais
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
43
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
Fra
nccedilais
44
DVA Network
AC26N est eacutequipeacute dune interface de reacuteseau proprieacutetaire deacutenommeacutee RDNET au moyen de laquelle il est possible de sinterfacer agrave lordinateur agrave travers un peacuteripheacuterique (RDNET control)
Pour cela un protocole de communication a eacuteteacute deacuteveloppeacute avec lequel il est possible de recevoir et denvoyer les donneacutees ce branchement permet de faire le monitorage en temps reacuteel des paramegravetres du diffuseur comme puissance de sortie tempeacuterature de lamplificateur eacutetat du limiteur etc Il est aussi possible de seacutelectionner diffeacuterentes eacutegalisations ou den creacuteer de nouvelles et de reacutegler les niveaux de volume souhaiteacutes au moyen dun plug-in approprieacute
On conseille de teacuteleacutecharger gratuitement le logiciel DVA Network directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
DVA USB Manager
On conseille de teacuteleacutecharger gratuitement le logiciel DVA USB Manager directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
Le micrologiciel du module amplificateur peut ecirctre remis agrave jour par le port USBPour rendre cette mise agrave jour possible et facile un programme speacutecifique a eacuteteacute deacuteveloppeacute
DOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
CONNEXIONS DU PANNEAU ARRIEgraveRE
1586 75 141210 11 13 169 17
14) Connecteur ldquo USBrdquoCe connecteur USB (type B) permet de connecter le processeur agrave un ordinateur pour le controcircle et la mise agrave jour du micrologiciel via un programme deacutedieacute (DVA Network)
15) PRISE DALIMENTATION MAINSPermet la connexion du cacircble dalimentation fourni de seacuterie
16) PORTE-FUSIBLE FUSELogement pour fusible de ligne
17) INTERRUPTEUR GENERAL POWERLinterrupteur permet de mettre en marche ou deacuteteindre le controcircleur audio
COMMANDES ET FONCTIONS
5) SELECTEUR ldquo-6dBrdquoLe seacutelecteur permet de reacuteduire de 6dB les niveaux dentreacutee analogiques XLR [6] tout en compensant les niveaux eacuteleveacutes de sortie des meacutelangeurs ou dautres dispositifs audio Quand la barre du niveau de signal des entreacutees sur laffichage [1] reste au maximum cela indique que le niveau du signal entrant est eacuteleveacute Il est alors conseilleacute dutiliser latteacutenuation -6dBIl est possible de veacuterifier quand le seacutelecteur est activeacute par le menu Option
6) CONNECTEURS DENTREE ldquoArdquo ET ldquoBrdquoEntreacutees eacutequilibreacutees au niveau de la ligneIls sont en mesure daccepter des connecteurs XLR macircles
7) CONNECTEURS DE SORTIE ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo ET ldquo6rdquoSorties eacutequilibreacutees au niveau de la ligne Ils sont en mesure daccepter des connecteurs XLR femelles
Prendre garde agrave brancher convenablement les sorties sur les diffuseurs ou les amplificateurs en fonction des configurations de chaque canal pour eacuteviter des deacutegacircts et des problegravemes de fonctionnement
Section ldquoAESEBUrdquo
8) CONNECTEUR DENTREE INOutre les entreacutees audio analogiques une entreacutee audio numeacuterique SPDIF-AESEBU (AES3) a eacuteteacute preacutevue et peut ecirctre seacutelectionneacutee par le menu de setupLentreacutee requiert une connexion eacutequilibreacutee en utilisant un connecteur XLR avec un cacircble agrave 3 conducteurs de 110ohm torsadeacute
9) CONNECTEUR DE SORTIE OUTCe connecteur permet de relancer le signal audio dans les entreacutees analogiques ou numeacuteriques ou sur les sorties La source doit ecirctre reacutegleacutee par le menu OptionLa connexion sera conforme agrave la mecircme norme que lentreacutee [reacutef8]
Section ldquoRDNETrdquo
10) CONNECTEUR DENTREE DATA INPUTConnecteur RJ45 entreacutee de donneacutees
11) CONNECTEUR DE SORTIE DATA LINKConnecteur RJ45 sortie de donneacutees pour la connexion de seacuterie en cascade
12) VOYANT LUMINEUX ONCe voyant de couleur verte sallume uniquement quand lAC26N a reconnu et est connecteacute agrave luniteacute principale RDNET par lordinateur
13) VOYANT LUMINEUX ACTIVECe voyant de couleur jaune clignote quand une transmission des donneacutees est active entre RDNET et le dispositif
PUSH
P SHU
SHPU
P SHU
PUSH
CONNEXIONS
Audio analogiquesLes connexions eacutequilibreacutees permettent de reacuteduire au minimum le bruit provoqueacute par les cacircbles et dutiliser de longs cacircblesCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLe connecteur XLR doit ecirctre brancheacute avec la broche 1 agrave la masse la broche 2 au chaud (+) et la broche 3 au froid (-) En cas de cacircble blindeacute brancher le blindage agrave la broche 1Les cacircbles de connexion XLR-XLR et XLR-Jack14(63mm) peuvent semployer pour la connexion agrave lAC26N
12
3
Entreacutee
Entreacutee
XLR - femme
XLR - femme
1 2
3
Sortie
Sortie
XLR - Macircle
XLR - Macircle
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2 = Point chaudPhase +VE
Broche 3 =Point froidPhase -VE
Broche 3 =Point froidPhase -VE
Anneau
Manchon
Pointe Point chaudPhase +VE
Anneau = Point froidPhase -VE
ManchonB Masselindeacute
Pointe
Les connexions deacuteseacutequilibreacutees peuvent semployer mecircme si le bruit provoqueacute par les cacircbles augmente Les cacircbles ne peuvent deacutepasser 5m de longCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLes connexions deacuteseacutequilibreacutees peuvent abaisser le niveau du signal entrant de 6dB Pour remeacutedier agrave cet inconveacutenient il faut brancher la broche 3 agrave la masse mecircme si cela augmente le bruit
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
45
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
46
12
3
1 2
3
Pointe Manchon
Pointe = Signal
Broche 3 = Link to Pin 1
Broche 3 = Link to Pin 1
ManchonB Masselindeacute
Audio numeacuteriques (AESEBU)
AESEBU (protocole AES3) est une entreacutee eacutequilibreacutee isoleacutee eacutelectriquement agrave laide dun transformateur Elle permet demployer deux canaux audio dans un seul cacircble bipolaire blindeacute Les caracteacuteristiques du cacircble doivent ecirctre de 3 pocircles impeacutedance 100ohm torsadeacute et blindeacute avec connecteur XLR (AES3 standard)
RJ 45
|1|2|3|4|5|6|7|8|
RDnet
Chaque port RDNet des Control 2 et Control 8 peut ecirctre brancheacute agrave un maximum de 32 dispositifs compatibles placeacutes en cascade Dans lexemple suivant le port de luniteacute de controcircle RDNET CONTROL 2 est relieacute agrave lentreacutee DATA INPUT dun AC26N dont la sortie parallegravele DATA LINK est envoyeacutee agrave lentreacutee de lAC26N successif Dans lexemple [n] est un nombre compris entre 3 et 32 (limite maximale des dispositifs que lon peut relier agrave un sous-reacuteseau)
La longueur totale du cacircble CAT5 dun sous-reacuteseau NE peut PAS deacutepasser 900 megravetres
Le connecteur doit ecirctre relieacute comme 1 ndash disponible pour dautres fonctions (par exemple audio +) 2 ndash disponible pour dautres fonctions (par exemple audio )3 ndash disponible pour dautres fonctions (par exemple masse analogique)4 ndash masse numeacuterique5 ndash masse numeacuterique6 ndash disponible pour dautres fonctions (par exemple alimentation)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
MISE EN MARCHE
Lors de la mise en marche du dispositif linitialisation deacutebute et dure quelques secondes Leacutecran affiche le modegravele le logo et la barre de progression du chargement du programme
En fin de processus dinstallation leacutecran affiche la fenecirctre du menu Meters Pour connaicirctre les indications en deacutetail consulter le paragraphe DESCRIPTION FENETRE MENU Meters
LAC26N est precirct agrave lemploi
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION ET VISUALISATION
Pour entrer dans la fenecirctre du menu principal il faut pousser sur la touche MENU ( ) agrave lavant du dispositifDune page quelconque du menu en poussant sur la touche ESCrdquo ( ) on revient automatiquement sur la page-eacutecran preacuteceacutedente
MENU PRINCIPAL
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Le processeur contient six menus Ils montrent etou configurent les paramegravetres du systegravemeLes menus principaux sont
Meters Visualisation des niveaux des entreacutees et des sorties visualisation du programme utiliseacute et eacutetat mute rapide
Preset Meacutemoriser enregistrer et eacuteliminer les configurations du systegraveme
Matrix seacutelectionner les sorties en fonction du signal entrant
Ch Job configuration de chaque signal
X-Over configurer les freacutequences de coupure et les types de filtres pour chaque sortie
Option attribution des entreacutees et des sorties contraste daffichage la version du micrologiciel les entreacutees et dautres options
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
47
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
48
DESCRIPTION DE LA FENETRE MENU Metersrdquo
Cette fenecirctre permet de visualiser les configurations et leacutetat geacuteneacuteral des entreacutees et des sorties la version du programme utiliseacute son eacutetat et le mode de pilotage du systegraveme
Les menus et les options afficheacutees peuvent se seacutelectionner en tournant la manette ldquoFUNCTIONS SETECTORrdquo ( ) Pour avoir accegraves agrave linteacuterieur de la seacutelection il faut mettre le paramegravetre souhaiteacute en eacutevidence et pousser sur la manette ldquoPush Enterrdquo ( | ) Il faut en faire de mecircme pour seacutelectionner etou modifier les options dans les commandes du menu
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositifAvec des signaux dentreacutee numeacuteriques les indications ldquoArdquo et ldquoBrdquo correspondent agrave lentreacuteeEn tournant la manette ldquoFUNCTIONS SELECTORrdquo [2] on fait deacutefiler en mode cyclique les canaux dentreacutee de sortie et lindication de mute geacuteneacuteral (d) le canal seacutelectionneacute est mis en eacutevidence
b) BARRE DE NIVEAU DE COMPRESSIONMUTE CANAL
COMPRESSION DE SIGNALLa compression du signal est visualiseacutee par le deacutefilement de la barre de droite de haut en bas
MUTE Chaque canal peut ecirctre placeacute en mute Seacutelectionner le canal et pousser sur la manette ldquoPush Enterrdquo [2] pour valider le changement deacutetat Lindication du canal sera remplaceacutee par la lettre M et la barre sera totalement mise en eacutevidencePour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterations
c) BARRE DE NIVEAU DE SIGNALLindication du niveau de chaque canal est signaleacutee par le deacutefilement de la barre de gauche
d) MUTE GENERALIl est possible de mettre simultaneacutement toutes les entreacutees et les sorties en mute Tourner la manette ldquoFUNCTIONS SELECTORrdquo seacutelectionner la lettre M et pousser sur la manette Push EnterPour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterationsLe mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) MODES DE COMMANDEIl affiche le mode dutilisation etou les dispositifs qui sont relieacutes agrave lAC26N
Local = utilisation autonome Aucune connexion agrave un dispositif exteacuterieur
NET = relieacute directement au reacuteseau deacutedieacute RDNet et agrave lordinateur
USB = relieacute directement agrave un ordinateur par cacircble USB
f) INDICATION DETAT DE PARAMETRAGECette indication permet de constater si un ou plusieurs paramegravetre(s) du programme chargeacute aont eacuteteacute modifieacute(s) par rapport au dernier sauvetage
= programme dorigine
= programme avec des paramegravetres modifieacutes
g) PROGRAMME CONFIGURELe chiffre indique le programme chargeacute et utiliseacute par le systegraveme agrave lemplacement de sauvetage Consulter le menu de Preset pour de plus amples deacutetails
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
DESCRIPTION DE LA FENETRE MENU Ch Job
Cette fenecirctre permet dafficher la configuration de chaque canal
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) NIVEAU DU SIGNALIndique le gain du signal Laugmentation de lintensiteacute dun signal est libelleacutee en deacutecibel (dB) Le paramegravetre peut ecirctre seacutelectionneacute de -8000dB agrave +2000dB avec des pas de 001dB Une augmentation de 6dB est eacutegale approximativement au redoublement agrave leacutechelle lineacuteaire du niveau du signal sous tensionAvec un gain supeacuterieur agrave 0dB le signal est amplifieacute tandis quavec un gain infeacuterieur agrave 0dB le signal est atteacutenueacute
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
49
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
50
c) DELAI DU SIGNAL (DELAY)Le signal audio reproduit peut ecirctre retardeacute pour permettre lalignement acoustique Cela compense les diffeacuterentes positions des diffuseurs pendant linstallation et la reproduction sonore Il se libelle en mS Le paramegravetre peut ecirctre seacutelectionneacute de 00mS agrave 729mS avec un pas de 01mSPour aligner un signal audio il est possible dutiliser la formule suivante
Deacutelai = (GAPx1000)344
Deacutelai = ms (en millisecondes)GAP = distance du diffuseur du point de reacutefeacuterence (en megravetres)Vitesse du son = 344ms
d) MUTEChaque canal peut ecirctre placeacute en mute La mecircme commande peut ecirctre activeacutee dans la fenecirctre du menu meters NB Le mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) PhasePermet la rotation de phase de 180deg par rapport au signal entrantCette rotation permet loptimisation surtout des basses freacutequences dans les installations complexes
f) EGALISATIONCette commande ouvre la fenecirctre du menu deacutegalisation de chaque canal Elle sert surtout pour corriger une ou plusieurs freacutequences qui doivent ecirctre atteacutenueacutees ou augmenteacutees
M M
LAC26N gegravere 12 filtres par canal dentreacutee et sortie avec trois types de configurations diffeacuterentes - Leacutegaliseur PEQ (peaking equalizer) est ideacuteal pour identifier isoler et
corriger une seule plage de freacutequences bien deacutetermineacutee Toutes les freacutequences passent mais il augmente ou diminue uniquement celles autour de la freacutequence centrale pour une bande preacutecise et un gain deacutefini
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessus de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessous de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
f Numeacuterotation des 12 filtres disponibles pour cette entreacutee ou cette sortie1
f Le type de filtre est afficheacute 2
Dis Deacutesactiveacute (absent)
PEQ Peaking equlizer
Sh H Filtre high-shelf
Sh L Filtre high-shelf
Exemples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
REMARQUELe paramegravetre Bw deacutetermine le champ de freacutequences adjacent agrave la freacutequence configureacutee ougrave est activeacute le filtre Plus la valeur Bw est eacuteleveacutee plus vaste est le champ de freacutequences (1Bw=1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONCette commande ouvre la fenecirctre du menu de compression de chaque canal
g1) TresholdIdentifie le seuil ougrave commence le rapport de compression La valeur de base 11
g2) RatioIndique le rapport de conversion entre le signal entrant et le signal sortant
g3) Post Gain Attach Release HoldCes donneacutees deacutependent du rapport de conversion que lon veut obtenir - Post Gain est le gain de sortie- Attack est le temps dattaque - Release est le temps de relacircchement- Hold est le temps de maintien
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
52
DESCRIPTION DE LA FENETRE MENU Preset
Cette fenecirctre permet de meacutemoriser jusquagrave 32 configurations dans lAC26NLe fabricant fournit le systegraveme avec un programme configureacute et enregistreacute en position 0 et non susceptible deacutecrasement
032 Elle indique lemplacement de sauvetage de la configurationCe numeacutero apparaicirct dans la fenecirctre Meters en position (g) A tout moment le programme utiliseacute peut ecirctre afficheacute par lutilisateur
Empty Preset Cest le nom qui est associeacute au numeacutero de lemplacement quand aucune configuration (vide) nest enregistreacutee
Local preset Local preset est le nom qui est associeacute au numeacutero de lemplacement quand on enregistre une configuration NB = Il est possible denregistrer une configuration avec lenom souhaiteacute de 16 lettres tout au plus agrave condition que lonutilise linterface via lordinateur
Le nom du programme assigneacute est indiqueacutePour toucher agrave lapplication 3 choix soffrent agrave vous
Save Le programme est enregistreacute en meacutemoire de lAC26N
Del Le programme est effaceacute
Load Le programme est chargeacute et precirct agrave lemploi
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
51
DESCRIPTION DE LA FENETRE MENU X-Over
Cette fenecirctre permet de seacutelectionner un filtre passe bas un filtre passe haut ou par la combinaison des deux de creacuteer un filtre passe bande pour chaque sortieLe filtre actif est un Linkwitz-Riley qui permet de seacutelectionner la pente de 12dBoct 24dBoct ou 48dBoct et sa freacutequence de coupure
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) CANAUX DE SORTIE
Les connecteurs de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) FILTRE CROSSOVERSeacutelectionner le filtre selon les besoins Il est possible de seacutelectionner
Dis Aucun filtre activeacute
HP Filtre passe-haut laisse passer uniquement la partie de signal audio supeacuterieure agrave la freacutequence de coupure
LP Filtre passe-bas laisse passer uniquement la partie de signal audio infeacuterieure agrave la freacutequence de coupure
Configuration du filtre Passe-haut Passe-bas
Rien Dis Dis
Passe-haut HP Dis
Passe-bas Dis LP
Passe-bande HP LP
12dBoct
24dBoct
Hz
dB
Ga
in 48dBoct
12dBoct
24dBoct
Hz
dB
Ga
in
48dBoct
c) PENTE DATTENUATIONSeacutelectionner la pente datteacutenuation du signal audio en fonction de la diminution que lon veut obtenir Plus la pente datteacutenuation est eacuteleveacutee agrave eacutegaliteacute de freacutequence de coupure plus eacuteleveacutee sera la seacutelection du signal Il est possible de seacutelectionner
12 correspond agrave 12dboct
24 correspond agrave 24dboct
48 correspond agrave 48dboct
d) FREQUENCE DE COUPUREElle permet de reacutegler la freacutequence de passage des freacutequences infeacuterieures (filtre passe-bas) ou des freacutequences supeacuterieures (filtre passe-haut) uniquementLe choix de la coupure deacutepend de la reproduction que lon veut obtenirLuniteacute de mesure utiliseacutee est lHz
Hz
Hz
dB
dB
Ga
in
f0
f0
0dB0dB
0dB
-6dB
freacutequence
freacutequence
freacutequence
freacutequence
Ga
in
f0
0dB
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
53
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
54
DESCRIPTION DE LA FENETRE MENU Matrix
Elle permet de seacutelectionner le signal entrant agrave utiliser comme source pour chaque sortie
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) CANAUX DE SORTIEIdentification du canal sortant agrave reacutegler
b) IDENTIFICATIONS DES ENTREESSeacutelectionner le type de signal agrave associer agrave chaque sortie en fonction des besoins Il est possible de seacutelectionner
In A Le signal entrant A est associeacute
In B Le signal entrant B est associeacute
In A+B La somme algeacutebrique des deux signaux entrants A et B est associeacutee
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
DESCRIPTION DE LA FENETRE MENU Option
Permet dafficher les reacuteglages du systegraveme comme lassignation des entreacutees et des sorties latteacutenuation le contraste de laffichage et la version du logiciel
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcCette option permet de reacutegler le type de signal audio entrant
An In =signaux audio analogiques (entreacutees ldquoArdquo et ldquoBrdquo)
Dig In =signaux audio numeacuteriques (entreacutee AESEBU)
DigOut SrcCette option permet de seacutelectionner la source audio qui sera adresseacutee sur le connecteur AESEBU OUT (sortie numeacuterique)
An In = signaux audio des entreacutees analogiques
Dig In =signaux audio sur lentreacutee numeacuterique
OUT 1-2 = signaux audio sur les sorties 1 et 2
OUT 3-4 = signaux audio sur les sorties 3 et 4
OUT 5-6 = signaux audio sur les sorties 5 et 6
Input ModePermet de configurer les entreacutees
Indip = sont indeacutependantes et autonomes Ne sont soumises agrave aucun type de lien
Linked = sont unies et fonctionnent en mode steacutereacuteo Les compresseurs les filtres les deacutelais le volume sont identiques pour les deux canaux
Atten PadIndique le mode de reacuteglage du seacutelecteur ldquo-6dBrdquo placeacute agrave larriegravere [reacutef 5] Il faut activer ce seacutelecteur quand les niveaux dentreacutee analogiques sont trop eacuteleveacutes Le seacutelecteur sactive uniquement par le bouton Dans le menu il sagit dune simple visualisation
0dB = seacutelecteur non activeacute Les signaux dentreacutee sont identiques agrave la source entrante
-6dB = seacutelecteur activeacute Les signaux entrants sont atteacutenueacutes de -6dB par le processeur interne
ContrastIl permet de reacutegler le contraste de laffichage agrave cristaux liquides pour compenser la diffeacuterence de luminositeacute avec le lieu dinstallation Une plus grande clarteacute de laffichage permet de naviguer convenablement et rapidement dans les menusLe reacuteglage agrave la sortie de lusine du fabricant est de 60
10 plus clair 60 plus fonceacute 100
Fw VersIndique la version du logiciel du processeur
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
55
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
56
DONNES TECHINIQUES
PERFORMANCES AUDIOReacuteponse en freacutequence +- 01dB (20 to 30kHz)Plage dynamique 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsion 0002 (1kHz +4dBu)
PERFORMANCES AUDIO NUMERIQUES Processeur DSP 2856-bit Freacutequence de traitement des donneacutees 48KHzConvertisseurs analogiques 24-bit BURR BROWNDeacutelai de propagation 15msMeacutemorisations des configurations 32 preset
CONTROLES Affichage LCD graficoBoutonsCommandes ESC - MENU - FUNCTIONS SELECTION
ENTERENTREESSORTIESEntreacutee analogique ndeg2 x XLR (3 broches femelle)
Impeacutedance dentreacutee gt10KOhmNiveau maximum +21dBu senza PAD
+27dBu con PADSortie analogique ndeg6 x XLR (3 broches macircle )
Impeacutedance de sortie 50OhmNiveau maximum +21dBuType Balanceacute
Entreacutee numeacuterique ndeg1x XLR (3 broches femelle)Type SPDIF-AESEBU (AES3)
Sortie numeacuterique ndeg1x XLR (3 broches macircle )Type conforme agrave la norme de lentreacutee
EntreacuteesSortie Rdnet ndeg2 x XLR RJ45 (cacircble CAT 5)USB Type B
PARAMETRES DE CONTROLE DU SONGain -80dB a +20dB eacutetape 01dBDeacutelai Entreacutee 0 a 729mS eacutetape 01 mS
Sortie 0 a 340mS eacutetape 01mSRotation de phase 0deg - 180deg
COMPRESSIONSeuil -80dB a +20dB eacutetape 01dBRapport 11 a Inf1 eacutetape 001Gain agrave la sortie 0dB a 40dB eacutetape 01dBTemps dattaque 1mS a 1000mS eacutetape 01mSTemps de relacircchement 1mS a 1000mS eacutetape 01mSTemps de maintien 1mS a 1000mS eacutetape 01mS
EGALISEURS12 eacutegaliseurs pour chaque entreacutee et sortieType PEQ (parameacutetrique) Hi-shelf Lo-sheft
Freacutequence 20Hz a 20KHz eacutetape 1HzGain -30dB a +15dB eacutetape 001dBBande 005dB a 2dB eacutetape 001dB (uniquement pour PEQ)
FILTRES CROSSOVERFiltre Linkwitz Riley
Type HF high-shelfLF low-shelf
Pente 12dBoct - 24dBoct - 48dBoctFreacutequence de coupure 5Hz a 20KHz eacutetape 1Hz
ALIMENTATION Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)POIDS 19Kg
Remarques Speacutecifications sujettes agrave modifications sans preacuteavis
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
2 VIE ATTIVO2 WAY ACTIVE
3 VIE PASSIVO3 WAY PASSIVE
L
L
A
A
HIGH L
MID L
LOW HIGHMID RHIGHMID L
LOW L
HIGH R
MID R
LOW R
R
R
B
B
1
1
2
2
3
3
456
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
Menu Matrix configurationMatrix
57 58
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
EROUIG ATRIX TNM
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
OU
TP
UT
1
OU
TP
UT
2
OU
TP
UT
3
OU
TP
UT
4
OU
TP
UT
5
OU
TP
UT
6
AE
S-E
BU
OU
TP
UT
INP
UT
A
AE
S-E
BU
INP
UT
INP
UT
B
D D D D D D
D D
A A A A A A
A SA
MP
LE
RA
TE
CO
NV
A
LIN
KA
BL
E
SC
HE
MA
A B
LO
CC
HI -
BL
OC
K D
IAG
RA
MB
LO
CK
SC
HA
LT
BIL
D -
SC
HE
MA
S F
ON
CT
ION
NE
LS
LINE ARRAY SUB MONO ATTIVO
LINE ARRAY SUB MONO ACTIVEINGRESSI - INPUT
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
L
L
L
A
A
A
AESEBU IN
AESEBU IN
AESEBU IN
AESEBU OUT
AESEBU IN
AESEBU IN
AESEBU OUT
R
R
R
LR
B
B
B
123456
HIGHMID L
HIGHMID L HIGHMID R
HIGHMID R
LOW L LOW R
LAYER
DISPLAY MEMORY
FADER MODE
LAYER
DISPLAY MEMORY
FADER MODE
Ingresso ANALOGICO
ANALOG Input
Collegamento in cascata
Link connections
Ingresso DIGITALE
DIGITAL inputA B
BALANCED AUDIO INPUTS
-6dB
PUSH PUSH
IN OUT
AES EBUPUSH
Oppure
or
Oppure
or
Menu Option configurationOption
Menu Option configurationOption Menu Option configurationOption
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type Analog
AES out An In
Input type Analog
AES out An In
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
59 60
InA-B Src Dig InInA-B Src Dig InInA-B Src An InInA-B Src An In
frequenzaHz
dB
Gu
ad
ag
no
60 200 2800
0dB0dB
-6dB
Esempio di un sistema a 3-vie
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
Out 1 Out 2 Out 3
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Esempio di un sistema a 3-vie
61 62
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
26NAC 26NAC
R TE
DO
R
MO LEU O R CE S
E O TR L A
S O
O C ND I P
P hsuernE t
o su cti nF nel rS e tc o
E CSME UN
IGCHTE OL SN EOBd
ocaL l
M
0
484
467
430
44
31
75
12
7
DIMENSIONI DIMENSIONSABMESSUNGEN DIMENSIONS
Italia
no
Italia
no
Manuale
drsquou
soM
anuale
drsquou
so
1
Italia
no
Italia
no
Manuale
drsquou
soM
anuale
drsquou
so
2
INTRODUZIONE
AC26N egrave un processore audio digitale per la gestione di sistemi audio progettato per installazioni fisse e touring AC26N utilizza la tecnologia piugrave moderna con processori a 2856bit e convertitori ADDA a 24-bit ad alte prestazioni
Contenuto della confezione- AC26N - Manuale drsquouso- CD software- Cavo di alimentazione
Caratteristiche- 2 Ingressi e 6 uscite con indirizzamento flessibile- Ingresso e uscita stereo AESEBU indirizzabili - DSP 2856-bit- Convertitori AD BURR BROWN 24-bit ad alte prestazioni- Frequenza di risoluzione filtri 1 Hz - 12 Equalizzatori parametrici per ciascun ingresso e uscita- 2 filtri crossover per ogni uscita con pendenza selezionabile 122448dBoct- DRC multiconfigurazione ad alte prestazioni per configurazione
limitercompressione per ciascun ingresso e uscita- Livello regolabile in dB polaritagrave e ritardo (delay) per ogni ingresso e uscita- Aggiornamento firmware tramite PC- Display LCD grafico- 32 preset memorizzabili dallrsquoutente- Interfaccia USB per controllo e configurazione da computer- Interfaccia RDnet che permette di controllare fino a 256 dispositivi remoti
Le funzioni disponibili nel processore sono livelli di ingresso e uscita ritardo (delay) polaritagrave 12 bande di equalizzazione per canale di ingresso e uscita molteplici selezioni di incrocio (crossover) e limiter ad alte prestazioni Il controllo dei filtri ha una risoluzione di 1Hz Ingressi ed uscite possono essere impostate in diverse configurazioni per soddisfare qualsiasi esigenza AC26N puograve essere controllato in tempo reale e configurato in ogni parametro dal pannello frontale e da computer con interfaccia grafica intuitiva accessibile tramite il software laquoDVA Networkraquo e un collegamento di rete dedicata RDnet oppure USBLrsquoaggiornamento del software per la CPU e DSP tramite PC permette di mantenere il dispositivo aggiornato Ersquo possibile salvare e richiamare 32 configurazioni predisposte di configurazione
PC
PC
RDNET control(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FUNZIONI PANNELLO FRONTALE
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
COMANDI E FUNZIONI1) DISPLAY
Il display LCD grafico permette di visualizzare ed editare le informazioni dellrsquoAC26N senza lrsquouso del computer Il contrasto puograve essere settato allrsquointerno del menu principale
2) MANOPOLA ldquoFuncions Selectorrdquo E ldquoPush Enterrdquo Questo controllo permette di muoversi selezionare e variare i parametri allrsquointerno dei menu visualizzati sul displayRotazione della manopola (Functions Selectors)- permette di muoversi allrsquointerno delle varia pagine del menu- permette la variazione dei parametri selezionatiPressione della manopola (Push Enter)- permette la selezioneconferma dei parametri
3) Pulsante ldquoESCrdquo Questo pulsante consente di uscire dai menu visualizzati o di ritornare alla visualizzazione precedente
4) Pulsante ldquoMenurdquo Questo pulsante permette di accedere direttamente al menugrave principale
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
DVA USB Manager
Il firmware del controller audio puograve essere aggiornato attraverso la porta USB Per rendere possibile e facile questo aggiornamento egrave stato sviluppato un programma dedicato
Si raccomanda di scaricare il software gratuito DVA USB Manager direttamente dal sito dB Technologies (wwwdbtechnologiescom) nella sezione dedicata laquoSoftware amp Controllerraquo
DVA Network
AC26N egrave equipaggiato con interfaccia di rete proprietaria denominata RDNET tramite la quale egrave possibile interfacciarsi al computer attraverso una periferica (RDNET control)A questo scopo egrave stato sviluppato il protocollo proprietario di comunicazione RDnet con il quale egrave possibile ricevere e inviare i dati questo collegamento permette di monitorare in tempo reale i parametri del diffusore come livello del segnale stato del limiter etc Ersquo possibile selezionare diversi valori di crossover delay volume ed aggiungere equalizzazioni tramite lrsquoapposito plug-in
Si raccomanda di scaricare il software gratuito DVA Network direttamente dal sito dB Technologies (wwwdbtechnologiescom) nella sezione dedicata laquoSoftware amp Controllerraquo
DOWNLOAD
DOWNLOAD
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquouso
Ma
nu
ale
drsquou
so
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquouso
Ma
nu
ale
drsquou
so
3 4
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
CONNESSIONI PANNELLO RETRO
1586 75 141210 11 13 169 17
14) Connettore ldquo USBrdquoQuesto connettore USB (tipo B) permette di collegare il processore ad un computer per il controllo e lrsquoaggiornamento del firmware tramite un programma dedicato (DVA Network)
15) PRESA DI ALIMENTAZIONE ldquoMAINSrdquoConsente la connessione del cavo di alimentazione fornito in dotazione
16) PORTA FUSIBILE ldquoFUSErdquoAlloggio per fusibile di rete
17) INTERRUTTORE GENERALE ldquoPOWERrdquoLrsquointerruttore permette lrsquoaccensione e lo spegnimento del controllore audio
COMANDI E FUNZIONI
5) SELETTORE ldquo-6dBrdquo
Ingressi bilanciati a livello lineaSono in grado di accettare connettori XLR maschio
Uscite bilanciate a livello linea Sono in grado di accettare connettori XLR femmina
Sezione ldquoAESEBUrdquo
8) CONNETTORE DI INGRESSO ldquoINrdquoIn aggiunta agli ingressi audio analogici egrave stato previsto un ingresso audio digitale SPDIF-AESEBU (AES3) selezionabile tramite il menu di setupLingresso richiede una connessione bilanciata utilizzando un connettore XLR con un cavo a 3 conduttori da 110ohm twistato
9) CONNETTORE DI USCITA ldquoOUTrdquoQuesto connettore permette di rilanciare il segnale audio presente negli ingressi analogici o digitali oppure presenti sulle uscite La sorgente deve essere impostata tramite il menugrave ldquoOptionrdquoLa connessione deve essere conforme allo stesso stardard dellrsquoingresso [rif8]
10) CONNETTORE DI INGRESSO DATA INPUTrdquoConnettore RJ45 ingresso dati
11) CONNETTORE DI USCITA DATA LINKrdquoConnettore RJ45 uscita dati per il collegamento seriale in cascata
12) INDICATORE LUMINOSO ldquoONrdquoQuesto indicatore di colore Verde si accende solo quando lrsquoAC26N ha riconosciuto ed egrave connesso con unitagrave principale RDNET tramite computer
13) INDICATORE LUMINOSO ldquoACTIVErdquoQuesto indicatore di colore Giallo lampeggia quanto egrave attiva una trasmissione dati tra RDNET e il dispositivo
Il selettore permette di ridurre di 6db i livelli di ingresso analogici XLR [6] contemporaneamente per compensare il livelli alti di uscita dei mixer o di altri dispositivi audio Quando la barra del livello segnale degli ingressi sul display [1] risulta sempre al massimo questo indica che il livello del segnale in ingresso egrave elevato e si consiglia di utilizzare lrsquoattenuazione -6dBErsquo possibile controllare quando il selettore egrave attivato dal menu ldquoOptionrdquo
6) CONNETTORI DI INGRESSO ldquoArdquo E ldquoBrdquo
7) CONNETTORI DI USCITA ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo E ldquo6rdquo
Prestare attenzione a collegare le uscite in modo corretto ai diffusori od agli amplificatori in base ai settaggi dei singoli canali per evitare danni e malfuzionamenti
Sezione ldquoRDNETrdquo
PUSH
P SHU
SHPU
P SHU
PUSH
COLLEGAMENTI
Audio analogiciLe connessioni bilanciate permettono di ridurre al minimo il rumore indotto dai cavi stessi e permettere la possibilitagrave di usare cavi di lunghezza importantiQueste connessioni possono essere utilizzate sia sugli ingressi che sulle usciteIl connettore XLR deve essere collegato con il pin 1 a massa pin 2 al caldo (+) e pin 3 al freddo (-) Nel caso di cavo schermato collegare la schermatura al pin 1I cavi ci connessione XLR-XLR e XLR-Jack14(63mm) possono essere utilizzati per il collegamento allrsquoAC26N
12
3
Ingresso
XLR - femmina
Pin 3 =NegativoFreddoFase -VE
1 2
3
Uscita
XLR - Maschio
Pin 2 = PositivoCaldoFase +VE
Pin 1 =SchermoTerraMassa
Pin 1 =SchermoTerraMassa
Pin 2 = PositivoCaldoFase +VE
Pin 3 =NegativoFreddoFase -VE
Anello
Gambo
Punta = PositivoCaldoFase +VE
Anello = NegativoFreddoFase -VE
Gambo=SchemoMassaTerra
Punta
Le connessioni sbilanciate possono essere utilizzate anche se il rumore indotto dai cavi stessi aumenta e i cavi non devono superare la lunghezza di 5mtQueste connessioni possono essere utilizzate sia sugli ingressi che sulle usciteI collegamenti sbilanciati possono abbassare il livello del segnale in ingresso di 6dB per ovviare a questo inconveniente egrave necessario collegare il pin 3 alla massa anche se questo puograve aumentare il rumore
12
3
Ingresso
XLR - femmina
1 2
3
Uscita
XLR - Maschio
Punta Gambo
Punta = Segnale
Gambo=SchemoMassaTerra
Pin 2 = PositivoCaldoFase +VE
Pin 1 =SchermoTerraMassa
Pin 3 = Connesso al Pin 1
Pin 3 = Connesso al Pin 1
Pin 1 =SchermoTerraMassa
Pin 2 = PositivoCaldoFase +VE
Audio digitali (AESEBU)AESEBU (protocollo AES3) egrave un ingresso bilanciato isolato elettricamente tramite un trasformatore Permette di utilizzare due canali audio in un singolo cavo bipolare schermato Le caratteristiche del cavo devono essere impedenza 100ohm twistato e schemato con connettore XLR (AES3 standard)
RD netCiascuna porta RDNet presente sui Control 2 e Control 8 puograve essere collegata a max 32 dispositivi compatibili posti in cascata
Nellrsquoesempio a seguito la porta dellunitagrave di controllo RDNET CONTROL 2 egrave collegata allingresso DATA INPUT di un AC 26N la cui uscita parallela DATA LINK egrave inviata allingresso del successivo AC26N Nellesempio [n] egrave un numero compreso tra 3 e 32 (limite massimo dei dispositivi da collegare ad una sotto rete)
RJ 45
|1|2|3|4|5|6|7|8|
La lunghezza complessiva del cavo CAT5 di una sotto rete NON puograve eccedere i 900 metri
Il connettore deve essere collegato come
1 ndash disponibile per altre funzioni (ad esempio audio +) 2 ndash disponibile per altre funzioni (ad esempio audio ndash)3 ndash disponibile per altre funzioni (ad esempio massa analogica)4 ndash massa digitale5 ndash massa digitale6 ndash disponibile per altre funzioni (ad esempio alimentazione)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
ACCENSIONEAllrsquo accensione del dispositivo si avvia lrsquoinizializzazione che dura alcuni secondi Sul display viene visualizzato il modello il logo e la barra avanzamento caricamento del programma
Al termine del processo di installazione sul display viene visualizzata la finestra del menugrave ldquoMetersrdquo Per conoscere le indicazioni nel dettaglio fare riferimento al paragrafo ldquoDESCRIZIONE FINESTRA MENUrsquo ldquoMetersrdquo
AC26N egrave pronto per lrsquoutilizzo
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquouso
Ma
nu
ale
drsquou
so
5
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquouso
Ma
nu
ale
drsquou
so
6
A B 1 2 3 4 5 6
CONFIGURAZIONE E VISUALIZZAZIONEPer accedere alla finestra del menugrave principale egrave necessario premere il tasto ldquoMENUrdquo ( ) posto sul frontale del dispositivo
ldquoESCrdquo ( ) Da una qualunque pagina del menu premendo il tasto si torna automaticamente alla schermata precedente
MENUrsquo PRINCIPALE
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
I menugrave presenti nel processore sono sei e mostrano eo configurano i parametri del sistemaI menugrave principali sono
Meters visualizzazione livelli degli ingressi e delle uscite visualizzazione programma utilizzato e stato mute rapido
Preset memorizzare salvare ed eliminare le configurazioni del sistema
Matrix selezionare le uscite in funzione del segnale in ingresso
Ch Job configurazione di ogni singolo canale
X-Over configurare le frequenza di taglio e i tipi di filtri per ogni singola uscita
Option assegnazione degli ingressi e delle uscite contrasto display la versione del firmware ingressi ed altre opzioni
I menugrave e le singole opzioni visualizzati possono essere selezionati ruotando la manopolaldquoFUNCTIONS SETECTORrdquo ( ) Per accedere allrsquointerno della selezione egrave necessario evidenziare il parametro desiderato e premere la manopola ldquoPush Enterrdquo ( |) Lo stesso procedimento deve essere adottato per selezionare eo modificare le opzioni alrsquointerno delle voci del menugrave stesso
DESCRIZIONE FINESTRA MENUrsquo ldquoMetersrdquoQuesta finestra permette di visualizzare le configurazioni e lo stato generale degli ingressi e delle uscite la versione del programma utilizzato il suo stato e come viene pilotato il sistema
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
7
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
8
a) CANALI INGRESSO E USCITAI connettori di ingresso ed uscita sono identificati utilizzando le medesime indicazioni presenti sulla serigrafia del retro del dispositivoCon segnali di ingresso digitali lrsquoindicazione ldquoArdquo e ldquoBrdquo corrispondono allrsquoingressoRuotando la manopola ldquoFUNCTIONS SELECTORrdquo [2] si scorrono in modo ciclico i canali ingresso uscita e indicazione di mute generale (d) il canale selezionato viene evidenziato
COMPRESSIONE SEGNALELa compressione del segnale viene visualizzata tramite lo scorrimento della barra di destra dallrsquoalto verso il basso
MUTE Ogni singolo canale puograve essere posto nelle condizione di mute Selezionare il canale e premere la manopola ldquoPush Enterrdquo [2] per confermare il cambiamento di stato Alla indicazione del canale verragrave sostituita la lettera ldquoMrdquo e la barra verragrave completamente evidenziataPer ripristinare il funzionamento normale ripetere le precedenti azioni descritte
c) BARRA LIVELLO SEGNALELrsquoindicazione del livello di ogni singolo canale viene segnalato tramite lo scorrimento delle barra di sinistra
d) MUTE GENERALEErsquo possibile mettere in mute tutti gli ingressi e le uscite contemporaneamente Ruotare la manopola ldquoFUNCTIONS SELECTORrdquo [2] selezionare la lettera ldquoMrdquoe premere la manopola ldquoPush Enterrdquo [2]Per ripristinare il funzionamento normale ripetere le precedenti azioni descritteIl mute generale ha la prioritagrave piugrave alta rispetto ai mute dei singoli canali
b) BARRA LIVELLO COMPRESSIONEMUTE CANALE
e) MODALITArsquo DI COMANDOViene visualizzato come egrave utilizzato eo a quali dispositivi egrave collegato lrsquo AC26N
Local = utilizzo stand-alone Nessuna connessione ad un dispositivo esterno
NET = collegato direttamente alla rete dedicate RDnet e al computer
USB = collegato direttamente ad un computer tramite cavo USB
f) INDICAZIONE STATO IMPOSTAZIONITramite questa indicazione viene visualizzato se il programma caricato egrave stato modificato in uno o piugrave parametri rispetto allrsquoultimo salvataggio
= programma originale
= programma con parametri modificati
g) PROGRAMMA IMPOSTATOIl numero indica il programma caricato ed utilizzato dal sistema riferito alla locazione di salvataggio Fare riferimento al menugrave di ldquoPresetrdquo per ulterioi dettagli
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
DESCRIZIONE FINESTRA MENUrsquo ldquoCh Jobrdquo
Questa finestra permette di visualizzare la configurazione di ogni singolo canale
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) CANALI INGRESSO E USCITAI connettori di ingresso ed uscita sono identificati utilizzando le medesime indicazioni presenti sulla serigrafia del retro del dispositivo
b) LIVELLO DEL SEGNALEIndica guadagno del segnale Laumento nella intensitagrave di un segnale egrave espresso in decibel (dB) Il parametro puograve essere selezionato da -8000dB a +2000dB con passi di 001dB Un aumento di 6dB egrave approssimativamente uguale al raddoppiamento in scala lineare del livello in tensione del segnaleCon un guadagno maggiore di 0dB viene amplificato il segnale mentre con un guadagno inferiore di 0dB viene attenuato il segnale
c) RITARDO DEL SEGNALE (DELAY)I segnale audio riprodotto puograve essere ritardato per permettere lrsquoallineamento acustico Questo compensa le diverse posizioni dei diffusori durante lrsquoinstallazione e la riproduzione sonora ed egrave espresso il mS Il parametro puograve essere selezionato da 00mS a 729mS con passo 01mSPer allineare un segnale audio egrave possibile utilizzare la seguente formula
Ritardo = (GAPx1000)344
Ritardo = ms (espresso in millisecondi)GAP = distanza del diffusore dal punto di riferimento (espresso in metri)
Velocitagrave del suono = 344ms
d) MUTEOgni singolo canale puograve essere posto nella condizione di mute Lo stesso comando puograve essere attivato nella finestra del menugrave laquometersraquo NB Il mute generale ha la prioritagrave piugrave alta rispetto ai mute dei singoli canali
e) FASEPermette la rotazione di fase di 180deg rispetto al segnale in ingressoQuesta rotazione permette lrsquoottimizzazione soprattutto delle basse frequenze nelle installazioni complesse
f) EQUALIZZAZIONEQuesto comando apre la finestra del menugrave dellrsquoequalizzazione del singolo canale Viene principalmente utilizzato per correggere una o piugrave frequenze che devono essere attenuate oppure aumentate
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
109
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
oLrsquo AC26N gestisce 12 filtri per ogni singolo canale di ingresso e uscita con tre diversi tipi configurazioni
Passano tutte le frequenze ma aumenta e diminuisce solo quelle attorno alla frequenza centrale per una determinata banda e un guadagno stabilito
- Equalizzatore high-shelf passa tutte le frequenze ma aumenta o attenua le frequenze sopra la frequenza di taglio selezionata per il guadagno indicato
- Equalizzatore low-shelf passa tutte le frequenze ma aumenta o attenua le frequenze inferiori alla frequenza selezionata per il guadagno indicato
- Equalizzatore PEQ (peaking equalizer) egrave ideale per identificare isolare e correggere solo una determinata gamma di frequenze
f Numerazione dei 12 filtri disponibili per quellrsquoingresso oppure uscita1
f Viene visualizzato il tipo di filtro2
Dis Disinserito (non presente)
PEQ Peaking equalizer
Sh H Filtro high-shelf
Sh L Filtro low-shelf
Esempi PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
NOTA BENEIl parametro Bw determina il campo di frequenze adiacenti alla frequenza impostata dove viene attivato il filtro maggiore egrave il valore Bw maggiore e egrave il campo di frequenze (1Bw=1 ottava)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONEQuesto comando apre la finestra del menugrave compressione del singolo canale
g ) Treshold1
Identifica la soglia dove inizia il rapporto di compressione Il valore di base 11
g ) Ratio2
Indica il rapporto di conversione tra il segnale in ingresso e quello in uscita
g ) Post Gain Attach Release Hold3
Questi dati sono in funzione del rapporto di conversione che si vuole ottenerePost Gain egrave il guadagno di uscitaAttack egrave il tempo di attacco Release egrave il tempo di rilascioHold il tempo di mantenimento
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
DESCRIZIONE FINESTRA MENUrsquo ldquoPresetrdquoQuesta finestra permette di memorizzare fino a 32 configurazioni nellrsquoAC26NLa ditta costruttrice fornisce il sistema con un programma impostato e salvato nella posizione ldquo0rdquo e non sovrascrivibile
032 Indica la locazione di salvataggio della configurazioneQuesto numero appare anche nella finestra ldquoMetersrdquo nella posizione (g) in qualsiasi momento il programma utilizzato puograve essere visualizzato dellrsquoutente
Empty Preset Ersquo il nome che viene associato al numero della locazione quando non egrave salvato nessun settaggio (vuoto)
Local preset Ersquo il nome che viene associato al numero di locazione quando viene salvata una configurazione NB = Ersquo possibile salvare un settaggio con il nome desiderato al max 16 lettere solo utilizzando lrsquointerfaccia tramite il computer
Selezionando un programma appare la seguente finestra
Viene indicato il nome del programma assegnatoPer intervenire sulla applicazione sono a disposizione 3 scelte possibili
Save Il programma viene salvato nella memoria dellrsquoAC 26N
Del Il programma viene cancellato
Load Il programma viene caricato e pronto per essere utilizzato
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
11
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
12
DESCRIZIONE FINESTRA MENUrsquo ldquoX-OverrdquoQuest a finestra permette di selezionare per ogni uscit a un filtro p assa basso un filtro p assa alto oppure tramite la combinazione di entrambe creare un filtro p assa bandaIl filtro presente egrave un Linkwitz-Riley dove egrave possibile selezionare la pendenza di 12dBoct 24dBoct oppure 48dBoct e la relativa frequenza di t aglio
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) CANALI USCITA
I connettori di uscita sono identificati utilizzando le medesime indicazioni presenti sulla serigrafia del retro del dispositivo
b) FILTRO CROSSOVERSelezionare il filtro a seconda delle necessitagrave Ersquo possibile selezionare
Dis Nessun filtro attivato
HP Filtro passa-alto lasciare passare solo la parte di segnale audio superiore alla frequenza di taglio
LP Filtro passa-basso lasciare passare solo la parte di segnale audio inferiore alla frequenza di taglio
Configurazione Filtro Passa basso Passa alto
Nessuna Dis Dis
Passa alto HP Dis
Passa basso Dis LP
Passa banda HP LP
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
c) PENDENZA DI ATTENUAZIONESelezionare la pendenza di attenuazione del segnale audio in base alla diminuzione che si desidera ottenere Piugrave elevata egrave la pendenza di attenuazione a paritagrave di frequenza di taglio maggiore egrave la selezione del segnale Ersquo possibile selezionare
12 corrisponde a 12dboct
24 corrisponde a 24dboct
48 corrisponde a 48dboct
d) FREQUENZA DI TAGLIOPermette drsquoimpostare la frequenza di passaggio delle sole frequenze inferiori (filtro passa-basso) o delle sole frequenze superiori (filtro passa-alto)La scelta del taglio egrave in funzione della riproduzione che si vuole ottenereLrsquounitagrave di misura utilizzata egrave Hz
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
DESCRIZIONE FINESTRA MENUrsquo ldquoMatrixrdquoPermette di selezionare per ogni uscita il segnale in ingresso da utilizzare come sorgente
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) CANALI USCITAIdentificazione del canale in uscita da impostare
b) IDENTIFICAZIONI INGRESSISelezionare il tipo di segnale da abbinare a ogni singola uscita in base alle proprie necessitagrave Ersquo possibile selezionare
In A Viene associato il segnale in ingresso laquoAraquo
In B Viene associato il segnale in ingresso laquoBraquo
In A+B Viene associato la somma algebrica dei due segnali in ingresso laquoAraquo e laquoBraquo
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
DESCRIZIONE FINESTRA MENUrsquo ldquoOptionrdquoPermette di visualizzare le impostazioni sistema come lrsquoassegnazione degli ingressi e delle uscite attenuazione il contrasto del display e la versione del firmware
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711
InA-B SrcQuesta opzione permette di impostare il tipo di segnale audio in ingresso
An In = segnali audio analogici (ingressi ldquoArdquo e ldquoBrdquo)
Dig In = segnali audio digitali (ingresso AESEBU)
DigOut SrcQuesta opzione permette di selezionare la sorgente audio che verragrave indirizzata sul connettore AESEBU OUT (uscita digitale)
An In = segnali audio presenti negli ingressi analogici
Dig In = segnali audio presenti sullrsquoingresso digitale
OUT 1-2 = segnali audio presenti sulle uscite 1 e 2
OUT 3-4 = segnali audio presenti sulle uscite 3 e 4
OUT 5-6 = segnali audio presenti sulle uscite 5 e 6
Input ModePermette di configurare gli ingressi
Indip = sono indipendenti ed autonomi non sono soggetti a vincoli di alcun genere tra di loro
Linked = sono uniti e funzionano in modalitagrave stereoI compressori i filtri i ritardi il volumesono identici per i due canali
13
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
14
Atten Pad
Indica come egrave impostato il selettore ldquo-6dBrdquo posto sul retro [rif 5] Ersquo necessario attivare questo selettore quando i livelli di ingresso analogici sono troppo elevati Il selettore viene attivato solo tramite il pulsante nel menugrave egrave solo una visualizzazione
0dB = selettore non attivatoI segnali di ingresso sono i medesimi della sorgente in ingresso
-6dB = selettore attivatoI segnali in ingresso vengono attenuati di -6dB dal processore interno
Contrast
Consente di regolare il contrasto del display LCD per compensare la differenza di luminositagrave con il luogo di installazione Una maggiore chiarezza del display permette di navigare allrsquointerno dei menugrave in modo corretto e veloceIl settaggio in uscita dalla ditta produttrice egrave 60
10 piugrave chiaro 60 piugrave scuro 100
Fw Vers
Indica la versione del firmware del processore
SPECIFICHE TECNICHE
PRESTAZIONI AUDIORisposta in frequenza +- 01dB (20 to 30kHz)Gamma dinamica 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsione 0002 (1kHz +4dBu)
PRESTAZIONI AUDIO DIGITALI Processore DSP 2856-bit Frequenza elaborazione dati 48KHzConvertitori analogici 24-bit BURR BROWNRitardo di propagazione 15msMemorizzazioni configurazioni 32 preset
CONTROLLI Diplay LCD graficoPulsantiComandi ESC - MENU - FUNCTIONS SELECTION
ENTER
INGRESSIUSCITEIngresso analogico ndeg2 x XLR (3 poli femmina)
Impedenza di ingresso gt10KOhmLivello massimo +21dBu senza PAD
+27dBu con PADUscita analogica ndeg6 x XLR (3 poli maschio)
Impedenza di uscita 50OhmLivello massimo +21dBu Tipo Bilanciato
Ingresso digitale ndeg1x XLR (3 poli femmina)Tipo SPDIF-AESEBU (AES3)
Uscita digitale ndeg1x XLR (3 poli maschio)Tipo conforme allo standard dellrsquoingresso
IngressiUscita RDnet ndeg2 x XLR RJ45 (cavo CAT 5)USB Tipo B
PARAMETRI CONTROLLO AUDIOGuadagno -80dB a +20dB passo 01dBRitardo
ingresso 0 a 729mS passo 01 mSuscita 0 a 340mS passo 01mS
Rotazione di fase 0deg - 180deg
COMPRESSIONESoglia -80dB a +20dB passo 01dBRapporto 11 a Inf1 passo 001Guadagno in uscita 0dB a 40dB passo 01dBTempo di attacco 1mS a 1000mS passo 01mSTempo di rilascio 1mS a 1000mS passo 01mSTempo di mantenimento 1mS a 1000mS passo 01mS
EQUALIZZATORI12 equalizzatori per ogni ingresso e uscitaTipo PEQ (parametrico) Hi-shelf Lo-sheft
Frequenza 20Hz a 20KHz passo 1HzGuadagno -30dB a +15dB passo 001dBBanda 005dB a 2dB passo 001dB (solo per PEQ)
FILTRI CROSSOVERFiltro Linkwitz Riley
Tipo HP Passa-AltoLP Passa-Basso
Pendenza 12dBoct - 24dBoct - 48dBoctFrequenza di taglio 5Hz a 20KHz passo 1Hz
ALIMENTAZIONE Full-range 100-240Vac 50-60HzDIMENSIONI 430482x43x130mm (LxHxD)PESO 19Kg
Note Specifiche soggette a variazioni senza preavviso
CLASSIFICAZIONE EMIIn accordo alle normative EN 55103 lapparato egrave progettato e idoneo allutilizzo in ambienti Elettromagnetici E3 o inferiori (E2 E1)
INTRODUCTIONAC26N is a digital sound processor for the management of audio systems designed for fixed and touring installations AC26N uses the most modern technology with 2856 bit processors and high performance 24 bits ADDA converters The functions available in the processor are input and output levels delay polarity 12 equalization bands for each input and output channel multiple crossover and high performance limiter The control resolution of the filters is 1Hz Inputs and outputs can be set according to many configurations to meet any need AC26N can be controlled in real time and each one of its parameters can be configured on the front panel and through a computer by means of an intuitive graphical interface accessible through the software DVA Network and a dedicated RDnet or USB network connectionThe CPU and DSP software update via PC allows to keep the device up to date It is possible to save and recall 32 preset configurations
Package Contents- AC26N - Operating manual- Software CD- Power cord
Characteristics- 2 Inputs and 6 Outputs with flexible routing- AESEBU addressable stereo inputs and outputs - 2856 bit DSP- BURR-BROWN high performance 24 bit AD converters- Frequency resolution of the filters 1 Hz - 12 parametric equalizers for each input and output- 2 crossover filters for each output with selectable slope 122448 dBoct- High performance DRC multi configuration for limitercompression configuration of
each input and output- Adjustable level in dB polarity and delay for each input and output- Firmware Update via PC- Graphic LCD Display- 32 pre-sets can be stored by the user- USB interface for configuration and control via computer- RDnet interface that allows to control up to 256 remote devices
PC
PC
RDNET hub(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FUNCTIONS FRONT PANEL
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
CONTROLS AND FUNCTIONS
1) DISPLAYThe graphic LCD display allows to view and edit the AC26N information without a computer The display contrast can be set within the main menu
2) ldquoFunctions Selectorrdquo and ldquoPush Enterrdquo KNOBThis control allows to move select and change the parameters within the displayed menusRotation of the knob (Function Selector)- it allows to browse the menu pages- it allows to change the selected parametersPush the knob (Push Enter)- it allows to selectconfirm the parameters
3) ESC button This control allows to exit the displayed menus or to return to the previous view
4) MENU button This control allows to directly access the main menu
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
En
glis
hE
nglis
hu
ser
man
ual
user
man
ual
16
user
man
ual
user
man
ual
Englis
hE
nglis
h
15
DVA USB Manager
The firmware of the amplifier module can be updated via the USB portTo make this update possible and simple a dedicated program has been developed
It is recommended to download DVA USB Manager free software directly from dB Technologies (wwwdbtechnologiescom) in the special section laquoSoftware amp Controllerraquo
DVA Network
The AC26N is equipped with proprietary network interface called RDNET for PC interface through a device (RDNET control)For this purpose a proprietary communication protocol has been developed for receiving and sending data this connection permits real-time monitoring of the diffuser parameters such as output power amplifier temperature limiter status etc It is also possible to select various equalizations or create new ones set the desired volume levels using the specific plug-in
It is recommended to download DVA Network free software directly from dB Technologies (wwwdbtechnologiescom) in the special section laquoSoftware amp Controllerraquo DOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
REAR PANEL CONNECTIONS
1586 75 141210 11 13 169 17
14) USB connectorThis USB connector (type B) allows to connect the processor to a compute to check and update the firmware via a dedicated program (DVA Network)
15) ldquoMAINSrdquo POWER CONNECTIONIt allows to connect the provided power cord
16) FUSE HOLDER ldquoFUSErdquoMain power supply fuse housing
17) ldquoPOWERrdquo MAIN SWITCHThis switch allows to switch on and off the device
PUSH
P SHU
SHPU
P SHU
PUSH
CONNECTIONS
Analog Audio ConnectionsBalanced connections allow to minimize the cable induced noise so cable can be longerSuch connections may be used both on inputs and outputsXLR connector must be cabled with pin 1 to ground pin 2 to hot (+) and pin 3 to cold (-) With shielded cables connect the shield to pin 1XLR-XLR e XLR-Jack 14(63 mm) connection cables can be used to connect the AC26N
12
3
Input
XLR - female
Pin 3 =NegativeCold-VE Phase
Pin 3 =NegativeCold-VE Phase
1 2
3
Output
XLR - Male
Pin 2 = PositiveHot+VE Phase
Pin 2 = PositiveHot+VE Phase
Pin 2 = PositiveHot+VE Phase
Pin 2 = PositiveHot+VE Phase
Pin 1 =ScreenGroundEarth
Pin 1 =ScreenGroundEarth
Pin 1 =ScreenGroundEarth
Pin 1 =ScreenGroundEarth
Ring
Sleeve
Tip = PositiveHot+VE Phase
Ring = NegativeCold-VE Phase
Sleeve=ScreenGroundEarth
Sleeve=ScreenGroundEarth
Tip
The unbalanced connections can also be used However the cable induced noise increases and cable length must not exceed 5 metersSuch connections may be used both on inputs and outputsUnbalanced connection may lower the level of the input signal up to 6dB in order to overcome this drawback connect pin 3 to ground although this can increase the noise
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
18
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
17
CONTROLS AND FUNCTIONS
5) -6dB SELECTORThis selector allows to reduce all the analog XLR [6] input levels by 6 dB at the same time to compensate for the high output levels on the mixers or other audio devices When the input signal level bar on the display [1] remains always at full scale this means that the input signal level is excessive and a -6 dB attenuation is recommendedIn the Option menu it is possible to check when the selector is activated
6) INPUT CONNECTORS ldquoArdquo AND ldquoBrdquoInputs balanced at line levelCapable to accept XLR male connectors
7) OUTPUT CONNECTORS ldquo1rdquo ldquo2rdquordquo 3rdquo ldquo4rdquo ldquo5rdquo AND ldquo6rdquoOutputs balanced at line level Capable to accept XLR famale connectors
Be careful to correctly connect each output to each speaker or amplifier according to the settings of each channels to avoid damages and malfunctions
ldquoAESEBUrdquo Section
8) INPUT CONNECTORIn addition to the analog audio inputs a SPDIF-AESEBU (AES3) digital audio input is also provided It can be selected via the setup menuSuch input requires a balanced connection trough an XLR connector with a 110 ohm twisted 3-wires cable
9) ldquoOUTrdquo OUTPUT CONNECTORThis connector allows to forward audio signals available at the digital or analog inputs or outputs The source must be set by means of the Option menuThe connection must comply with the same standard of the input [8]
RDNET Section
10) DATA INPUT CONNECTORData input RJ45 connector
11) ldquoDATA LINKrdquo OUTPUT CONNECTORRJ45 connector for data output used for serial link in cascade
12) ldquoONrdquo INDICATOR LIGHTThis green indicator turns on only when the AC26N has recognized the RDNET main unit and it is connected to it via computer
13) ldquoACTIVErdquo INDICATOR LIGHTThis yellow indicator flashes when data transmission between RDNET and the device is active
12
3
Input
XLR - female
1 2
3
Output
XLR - Male
Tip Gambo
Tip= Signal
Pin 3 = Link to Pin 1
Pin 3 = Link to Pin 1
Digital Audio Connections (AESEBU)AESEBU (AES3 protocol) is and a balanced input electrically insulated by means of a transformer It allows carrying two audio channels in a single two-wires shielded cable The cable characteristics are twisted 3 poles impedance 100 ohm shielded equipped with XLR connector (AES3 standard)
RDnetEach RDNet port on Control 2 and Control 8 can be connected to maximum 32 cascade-connected compatible devices In the example below the control unit RDNET CONTROL 2 port is connected to the DATA INPUT of an AC 26N whose parallel DATA LINK output is sent to the input of the next AC26N In the example [n] is a number between 3 and 32 (maximum limit for the devices connected to a sub-network)
RJ 45
|1|2|3|4|5|6|7|8|
The overall length of a CAT5 sub-network cable cannot exceed 900 meters
The connector must be connected as follows
1 - Available for other functions (for example audio +) 2 - Available for other functions (for example audio -)3 - Available for other functions (for example analog ground)4 - digital ground5 - digital ground6 - Available for other functions (for example power supply)7 - RS 485 A8 - RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
POWER ON
When the device is turned on the initialization procedure starts It lasts few seconds The display shows the device model the company logo and a program loading progress bar
At the end of the installation process the display shows the Meters menu For further details about the indications refer to the paragraph MENU DESCRIPTION - METERS
AC26N is now ready for use
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION AND DISPLAY
To access the main menu window press the MENU key located on the device front panelIn any page of the menu press the ESC button to return to the previous screen
MAIN MENU
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
There are six menus in the processor They show andor configure the system parametersThe main menus are
Meters Input and output levels display program in progress display quick muting
Preset Store save and delete the system configurations
Matrix Select the outputs according to the input signal
Ch Job Configuration of each individual channel
X-Over Configuration of the cut-off frequency and the types of filters for each output
Option Assignment of the inputs and outputs display contrast firmware version inputs and other options
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
20
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
19
The menus and the individual options displayed can be selected by rotating the knob ldquoFUNCTION SELECTORrdquo ( ) To access the selection highlight the desired parameter and press the ldquoPush Enterrdquo ( | ) knobThe same procedure should be adoptd to select andor change the options inside each menu entry
MENU DESCRIPTION - ldquoMetersrdquo
This window allows to view the configuration and the general conditions of the inputs and outputs the version of the program used the program status and how the system is driven
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) INPUT AND OUTPUT CHANNELSThe input and output connectors are identified by the same information provided on the screen printing located on the device rear sideWith digital input signals the indications A and B concern the inputBy rotating the knob FUNCTION SELECTOR [2] input channels output channels and general muting indications are cyclically scrolled (d) the selected channel is highlighted
b) BAR COMPRESSION LEVEL CHANNEL MUTING
SIGNAL COMPRESSIONSignal compression is displayed by the vertical scrolling (top to down) of the right bar
MUTE Each channel can be individually muted Select the channel and press the Push Enter knob [2] to confirm the change of status The indication of the channel will be replaced by the letter M and the bar will be completely highlightedTo restore normal operation repeat the actions described above
c) SIGNAL LEVEL BARThe level indication for each channel is provided by scrolling the left bar
d) GENERAL MUTINGIt is possible to mute all the inputs and outputs simultaneously Rotate the knob FUNCTION SELECTOR select the letter M and press the Push Enter knobTo restore normal operation repeat the actions described aboveThe general mute has the highest priority with respect to the muting of individual channels
e) CONTROL MODEIt shows how the AC26N is used andor to which devices it is connected
Local = stand-alone usage No connection to an external device
NET = directly connected to dedicated RDnet network and to computer
USB = directly connected to another computer via USB cable
f) SETTING STATUS INDICATIONThis indication shows if the loaded program was amended in one or more parameters with respect to the last saving operation
= original program
= program with modified parameters
g) SET PROGRAMThe number shows the program that is loaded and used by the system with reference to the saving position Refer to the ldquoPresetrdquo menu for further details
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
MENU DESCRIPTION - CH JOB
This window allows to view the configuration of each individual channel
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) INPUT AND OUTPUT CHANNELSThe input and output connectors are identified by the same information provided on the screen printing located on the device rear side
b) SIGNAL LEVELIt shows the signal gain The increased signal intensity is expressed in decibels (dB) Such parameter can be selected in the range from -8000 dB to +2000 dB in steps of 001 dB An increase of 6 dB is approximately equal to doubling - in a linear scale - the signal voltage levelIf the gain exceeds 0 dB the signal is amplified while if the gain is lower than 0 dB the signal is attenuated
c) SIGNAL DELAYThe reproduced audio signal may be delayed to perform an acoustic alignment This compensates for the different positions of the speakers during the installation and the sound reproduction it is expressed in ms The parameter can be selected in the range from 00 ms to 729 ms in steps of 01 msThe following formula can be used to align an audio signal
Delay = (GAPx1000)344
Delay = ms (in milliseconds)GAP = distance between speaker and reference point (in meters)Speed of sound = 344 ms
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
22
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
21
d) MUTEEach channel can be individually muted The same command can be activated in the Meters Menu
NOTE The general mute has the highest priority with respect to the muting of individual channels
e) PhaseIt performs a phase rotation of 180deg with respect to the input signalSuch phase rotation allows the optimization in special way for low frequencies in complex installations
M M
f) EQUALIZATIONThis control opens the menu controlling the single channel equalization It is mainly used to correct one or more frequencies that must be reduced or increased
The AC26N manages 12 filters for each individual channel input and output with three different kinds of configuration
- PEQ Equaliser (peaking equalizer) ideal to identify isolate and correct only a certain range of frequencies All frequencies pass only those around the centre frequency are increased and decreased for a given bandwidth and set gain
- High-shelf Equalizer All frequencies pass but frequencies above the selected cut-off frequency are increased or attenuated by the given gain
- Low-shelf Equalizer All frequencies pass but frequencies below the selected cut-off frequency are increased or attenuated by the given gain
f Numbering of the 12 available filters for the specific input or output1
f Displays the kind of filter2
Dis Switched off (not present)
PEQ Peaking equlizer
Sh H High-shelf Filter
Sh L Low-shelf Filter
Examples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
NOTE
The parameter Bw defines the range of frequencies close to the set frequency where the filter is activated the greater the value of Bw the wider is the frequencies range (1 Bw = 1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONThis control opens the menu controlling the compression for the single channel
g1) ThresholdIdentifies the starting threshold for the compression ratio Base value 11
g2) RatioIndicates the conversion ratio between input and output signal
g3) Post Gain Attach Release HoldThese data are in function of the conversion ratio to achieve Post Gain is the output gain Attack is the attack time Release is the release time Hold is the holding time
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
24
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
23
MENU DESCRIPTION - PRESET
This window allows to store up to 32 configurations in the AC26NThe manufacturer provides the system with a program set and saved in position 0 that is not possible to overwrite
032 Indicates the location where the configuration is savedThis number also appears in the window Meters in position (g) The program in use can be displayed at any time by the user
Empty Preset It is the name associated with the location number when no setting is saved (empty)
Local preset It is the name associated with the location number when a setting is saved NOTE = It is possible to save a setting with the desired name up to 16 letters only via the computer interface
When a program is selected the following window is displayed
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
The name of the assigned program is displayed3 possible choices are available when working on the application
Save The program is saved in the AC 26N memory
Del The program is deleted
Load The program is loaded and ready to be used
MENU DESCRIPTION - X-OVER
This window allows to select for each output a low pass filter a high pass filter or create a band-pass filter via the combination of bothThe available filter is a Linkwitz-Riley where it is possible to select slopes of 12 dBoct 24 dBoct or 48 dBoct and their cut-off frequency
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) OUTPUT CHANNELS
The output connectors are identified by the same information provided on the screen printing located on the device rear side
b) CROSSOVER FILTERSelect the filter according to needs It is possible to select
Dis No filter enabled
HP High-pass filter set it to allow only the part of audio signal above the cut-off frequency
LP Low-pass filter set to allow only the part of audio signal below the cut-off frequency
Filter configuration Low-pass High-pass
Nothing Dis Dis
High-pass HP Dis
Low-pass Dis LP
Band-pass HP LP
12dBoct
24dBoct
Hz
dB
48dBoct
12dBoct
24dBoct
frequency
frequency
frequency
frequency
Hz
dB
48dBoct
c) ATTENUATION SLOPESelect the attenuation slope of the audio signal on the basis of the desired attenuation The higher the attenuation slope at the same cut-off frequency the greater the signal selection It is possible to select
12 equal to 12 dBoct
24 equal to 24 dBoct
48 equal to 48 dBoct
d) CUT-OFF FREQUENCYTo set the passing frequency for the lower frequencies only (low-pass filter) or the higher frequencies only (high-pass filter)The choice of the cut-off depends on the desired sound reproductionThe unit of measurement used is Hz
Hz
Hz
dB
dB
Ga
inG
ain
Ga
inG
ain
f0
f0
0dB0dB
0dB
-6dB
-6dB
0dB
0dB
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
26
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
25
MENU DESCRIPTION - MATRIX
For each output it allows to select the input signal to use as the source
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) OUTPUT CHANNELSIdentification of the output channel to set
b) IDENTIFICATIONS OF THE INPUTSIt selects the type of signal to match each output as needed It is possible to select
In A Associated with the input signal ldquoArdquo
In B Associated with the input signal ldquoBrdquo
In A+B Associated with the algebraic sum of the two input signals ldquoArdquo and ldquoBrdquo
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
MENU DESCRIPTION - OPTION
Allows to display the system settings such as the allocation of the inputs and outputs attenuation display contrast and firmware version
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcThis option allows to set the type of input audio signal
An In = Analog audio signals (inputs A and B)
DigIn = Digital audio signals (AESEBU input)
DigOut SrcThis option allows to select the audio source that will be forwarded to the connector AESEBU OUT (digital output)
An In = Audio signals available at analog inputs
Dig In = Audio signals available at digital inputs
OUT 1-2 = Audio signals available on outputs 1 and 2
OUT 3-4 = Audio signals available on outputs 3 and 4
OUT 5-6 = Audio signals available on outputs 5 and 6
Input ModeIt allows to configure the inputs
Indip = They are independent not subject to constraints of any kind between them
Linked = They are connected and work in stereo mode Compressors filters delays volume are identical for the two channels
Atten PadIt shows how to set the -6 dB switch located on the rear side [Ref 5] It is necessary to activate this selector when the analog input levels are too high The selector can be activated only by means of the button the menu is for display only
0 dB = Selector not activated The input signals are the same as the input source
-6 dB = Selector activated The input signals are attenuated by -6 dB with reference to the inner
processor
ContrastAllows to adjust the LCD display contrast to compensate for the brightness difference at the installation sites Greater display brightness allows to navigate correctly and quickly within the menuThe manufacturer output setting is 60
10 More bright 60 More dark 100
Fw VersIt shows the processor firmware version
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
28
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
27
TECHINICAL SPECIFICATION
AUDIO PERFORMANCEFrequency Response +- 01dB (20 to 30kHz)Dynamic Range 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistortion 0002 (1kHz +4dBu)
DIGITAL AUDIO PERFORMANCE Processor DSP 2856-bit Data processing Frequency 24-bit BURR BROWNAnalog converters 24-bit BURR BROWNPropagation Delay 15msStoring configurations 32 preset
CONTROLS Display LCD graficoButtonsControls ESC - MENU - FUNCTIONS SELECTION
ENTERINPUTSOUTPUTSAnalog Input ndeg2 x XLR (3 pole female)
Input impedance gt10KOhmMaximum Level +21dBu senza PAD
+27dBu con PADAnalog Output ndeg6 x XLR (3 pole male)
Output impedance 50OhmMaximum Level +21dBu Type Balanced
Digital Input ndeg1x XLR (3 pole female)Type SPDIF-AESEBU (AES3)
Digital Output ndeg1x XLR (3 pole male)Type Compliant with the input standard
RDnet InputsOutput ndeg2 x XLR RJ45 (CAT 5 cable)USB Tipo B
SOUND CONTROL PARAMETERSGain -80dB a +20dB step 01dBDelay
Input 0 a 729mS step 01 mSOutput 0 a 340mS step 01mSPhase Rotation 0deg - 180deg
COMPRESSIONThreshold -80dB a +20dB step 01dBRatio 11 a Inf1 step 001Output gain 0dB a 40dB step 01dBAttack time 1mS a 1000mS step 01mSRelease time 1mS a 1000mS step 01mSHold time 1mS a 1000mS step 01mS
EQUALIZERS12 equalizers for each input and outputType PEQ (parametrico) Hi-shelf Lo-sheft
Frequency 20Hz a 20KHz step 1HzGain -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (only with PEQ)
CROSSOVER FILTERSFilter Linkwitz Riley
Type HP High-pass LP Low-pass
Slope 12dBoct - 24dBoct - 48dBoctCUT-OFF FREQUENCY 5Hz a 20KHz passo 1Hz
POWER SUPPLY Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)
1719x17x51 inch (WxHxD)WEIGHT 19Kg
(42 lbs)Note Specifications subject to change without notice
EMI CLASSIFICATIONAccording to the standards EN 55103 this equipment is designed and suitable to operate in E3 (or lower E2 E1) Electromagnetic environments
EINLEITUNG
Verpackungsinhalt
Eigenschaften
AC26N ist ein digitaler Audio-Prozessor fuumlr die Verwaltung von Audio-Systemen der fuumlr feste und mobile Installationen entwickelt wurde AC26N benutzt die modernste Technologie mit 2856 bit-Prozessoren und 24-bit-ADDA-Wandlern mit hoher Leistungsfaumlhigkeit Die verfuumlgbaren Funktionen des Prozessors sind Ein- und Ausgangsstufen Verzoumlgerung (delay) Polaritaumlt 12 Equalizer-Frequenzen fuumlr Ein- und Ausgangskanal viele Crossover-Wahlmoumlglichkeiten und Limiter mit hoher Leistung Die Filter-Kontrolle hat eine Aufloumlsung von 1 Hz Die Ein- und Ausgaumlnge koumlnnen mit unterschiedlichen Einstellungen geregelt werden um allen Anforderungen gerecht zu werden AC26N kann in Echtzeit kontrolliert werden und jeder Parameter kann am Frontpaneel und vom Computer mit intuitiver graphischer Schnittstelle mittels Software DVA Network zugaumlnglich und einer Netzverbindung RDnet oder uumlber USB eingestellt werdenDie SW-Aktualisierung fuumlr CPU und DSP uumlber PC erlaubt die Vorrichtung auf dem aktuellen Stand zu halten Man kann 32 vorgesehene Konfigurationen speichern und aufrufen
- AC26N - Bedienungsanleitung- Software-CD- Versorgungskabel
- 2 Ein- und 6 Ausgaumlnge mit flexibler Adressierung- Adressierbarer Stereo-Ein- und Ausgang AESEBU - DSP 2856-bit- AD-Wandler BURR BROWN 24-bit mit hoher Leistungsfaumlhigkeit- Aufloumlsungsfrequenz der Filter 1 Hz - 12 parametrische Equalizer fuumlr jeden Ein- und Ausgang- 2 Crossover-Filter fuumlr jeden Ausgang mit auswaumlhlbarer Neigung 122448dBoct- DRC Multikonfiguration mit hoher Leistungsfaumlhigkeit fuumlr die Konfiguration des
Limitersder Kompression jedes Ein- und Ausgangs- Einstellbare dB-Stufe Polaritaumlt und Verzoumlgerung (delay) fuumlr jeden Ein- und Ausgang- Firmware-Aktualisierung uumlber PC- Graphisches LCD-Display- 32 Voreinstellungen vom Benutzer einstellbar- USB-Schnittstelle fuumlr die Kontrolle und Konfiguration mit dem Computer- Schnittstelle RDnet welche erlaubt bis zu 256 fern liegende Vorrichtungen
zu kontrollieren
PC
PC
RDNET control(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FUNKTIONEN VORDERSEITE
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
BEDIENUNGEN UND FUNKTIONEN
1) DISPLAYDas graphische LCD-Display erlaubt die Informationen des AC26N ohne einen Computer zu benutzen anzuzeigen und zu editieren Der Kontrast kann im Hauptmenuuml eingestellt werden
2) DREHGRIFF Functions Selector UND Push EnterDiese Kontrolle erlaubt sich in den Menuumls auf dem Display zu bewegen und die Parameter auszuwaumlhlen und zu veraumlndernDrehung des Drehgriffes (Functions Selectors)- Man kann sich innerhalb der verschiedenen Menuumlseiten bewegen- Erlaubt die Veraumlnderung der ausgewaumlhlten ParameterDruck des Drehgriffes (Push Enter)- Erlaubt die AuswahlBestaumltigung der Parameter
3) Taste ldquoESCrdquo Diese Kontrolle erlaubt die angezeigten Menuumls zu verlassen oder zur vorherigen Anzeige zuruumlckzukehren
4) Taste ldquoMenuumlrdquo Diese Kontrolle erlaubt den direkten Zugang zum Hauptmenuuml
Deuts
chD
euts
chB
ed
ien
un
gsan
leit
un
gB
ed
ien
un
gsan
leit
un
g
29
Deuts
chD
euts
chB
ed
ien
un
gsan
leit
un
gB
ed
ien
un
gsan
leit
un
g
30
DVA USB Manager
Die Firmware des Verstaumlrkermoduls kann uumlber den USB-Anschluss aktualisiert werdenUm diesen Vorgang zu ermoumlglichen und zu vereinfachen wurde ein dediziertes Programm entwickelt das beim Hersteller angefordert und auf einen Computer installiert werden muss
Wir empfehlen die Software DVA USB Manager direkt von der Webseite dB Technologies (wwwdbtechnologiescom) im Abschnitt laquoSoftware amp Controllerraquo herunterzuladen
DVA Network
AC26N ist mit einer eigenen als RDNET bezeichneten Netzschnittstelle ausgestattet dank der es uumlber ein Interface (RDNET Control) an einen Computer angeschlossen werden koumlnnenHierzu wurde ein Kommunikationsprotokoll entwickelt mit dem die Daten empfangen und gesendet werden Dank dieser Verbindung koumlnnen die Lautsprecherparameter wie Ausgangsleistung Verstaumlrkertemperatur Limiterstatus usw in Echtzeit kontrolliert werden Auszligerdem koumlnnen verschiedene Entzerrungen ausgewaumlhlt bzw neue erstellt werden oder die gewuumlnschte Lautstaumlrke eingestellt werden
Wir empfehlen die Software DVA_Network direkt von der Webseite dB Technologies (wwwdbtechnologiescom) im Abschnitt laquoSoftware amp Controllerraquo herunterzuladenDOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
RUumlCKWANDANSCHLUumlSSE
1586 75 141210 11 13 169 17
14) USB-SteckverbinderDieser USB-Steckverbinder (Typ B) erlaubt den Prozessor an einem Computer anzuschlieszligen um die Firmware mit dem speziellen Programm (DVA Network) zu kontrollieren und zu aktualisieren
15) STROMANSCHLUSS MAINSErlaubt den Anschluss des mitgelieferten Versorgungskabels
16) SICHERUNGSTRAumlGER FUSEAufnahme fuumlr die Netz-Sicherung
17) HAUPTSCHALTER POWERDer Schalter erlaubt das Aus- und Einschalten des Audio-Controllers
BEDIENUNGEN UND FUNKTIONEN
5) WAHLSCHALTER -6dBDer Wahlschalter erlaubt das Level des analogen Eingangs XLR [6] um 6 dB zu verringern und gleichzeitig das hohe Ausgangslevel der Mixer oder anderer Audio-Vorrichtungen auszugleichen Wenn der Balken des Signallevels der Eingaumlnge auf dem Display [1] immer auf Maximum steht zeigt dies an dass das Signallevel am Eingang hoch ist und es wird empfohlen die Daumlmpfung -6dB zu benutzenIm Menuuml Option ist es moumlglich zu kontrollieren ob der Wahlschalter aktiviert ist
6) STECKVERBINDER AM EINGANG A UND BAuf Leitungslinie ausgeglichene EingaumlngeSie koumlnnen auch XLR-Steckdosen aufnehmen
7) AUSGANG-STECKVERBINDER ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo UND ldquo6rdquoAuf Leitungslinie ausgeglichene Ausgaumlnge Sie koumlnnen auch XLR-Stecker aufnehmen
Darauf achten dass die Ausgaumlnge korrekt entsprechend der Einstellungen der einzelnen Kanaumlle an den Lautsprechern oder Verstaumlrkern angeschlossen sind um Schaumlden und Fehlfunktionen vorzubeugen
Abschnitt ldquoAESEBUrdquo
8) EINGANGS-STECKVERBINDER INZusaumltzlich zu den analogen Audio-Eingaumlngen wurde ein digitaler Audio-Eingang SPDIF-AESEBU (AES3) vorgesehen der uumlber das Setup-Menuuml ausgewaumlhlt werden kannDer Eingang erfordert einen ausgeglichenen Anschluss mit einem XLR-Steckverbinder mit einem verdrillten Kabel mit 3 Leitern von 110 Ohm
9) AUSGANGS-STECKVERBINDER OUTDieser Steckverbinder erlaubt das Audiosignal an den analogen oder digitalen Eingaumlngen oder Ausgaumlngen zu verteilen Die Quelle muss uumlber das Menuuml Option eingestellt werdenDer Anschluss muss demselben Standard des Eingang entsprechen [Ref 8]
Abschnitt ldquoRDNETrdquo
10) EINGANGS-STECKVERBINDER DATA INPUTSteckverbinder RJ45 fuumlr den Dateneingang
11) AUSGANGS-STECKVERBINDER DATA LINKSteckverbinder RJ45 fuumlr den Datenausgang Fuumlr die serielle Kaskaden-Verbindung
12) LEUCHTANZEIGE ONDiese gruumlne Anzeige leuchtet nur wenn AC26N uumlber den Computer mit der Haupteinheit RDNET verbunden ist und diese erkannt hat
13) LEUCHTANZEIGE ACTIVEDiese gelbe Anzeige blinkt wenn eine Datenuumlbertragung zwischen RDNET und der Vorrichtung aktiv ist
PUSH
P SHU
SHPU
P SHU
PUSH
ANSCHLUumlSSE
Analoge Audio-AnschluumlsseDie ausgeglichenen Anschluumlsse erlauben die Geraumlusche der Kabel auf ein Minimum zu verringern und so die Benutzung langer Kabel zuzulassenDiese Anschluumlsse koumlnnen sowohl an den Ein- als auch an den Ausgaumlngen benutzt werdenDer XLR-Steckverbinder muss mit Pin 1 an Masse Pin 2 am Pluspol (+) und Pin 3 am Minuspol (-) angeschlossen werden Bei einem abgeschirmten Kabel muss die Abschirmung an Pin 1 liegenDie Verbindungskabel XLR-XLR und XLR-Jack 14 (63 mm) koumlnnen fuumlr den Anschluss
12
3
Eingang
XLR weiblichen
Pin 3 = MinuspolErkaumlltungphase -VE
Pin 3 = MinuspolErkaumlltungphase -VE
1 2
3
Ausgang
XLR maumlnnlichen
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Ring
Schaft
Spitze = PluspolWaumlrmephase +VE
Ring = MinuspolErkaumlltungphase -VE
Schaft=SchirmMasse
Spitze
Die nicht ausgeglichenen Anschluumlsse koumlnnen auch benutzt werden wenn die Kabelgeraumlusche ansteigen und diese Kabel duumlrfen nicht laumlnger sein als 5 MeterDiese Anschluumlsse koumlnnen sowohl an den Ein- als auch an den Ausgaumlngen benutzt werdenDie nicht ausgeglichenen Anschluumlsse koumlnnen das Signallevel am Eingang um 6 dB verringern um dem vorzubeugen muss Pin 3 an Masse angeschlossen werden obwohl dies das Geraumlusch verstaumlrken kann
12
3
Eingang
XLR weiblichen
1 2
3
Ausgang
XLR maumlnnlichen
Spitze Schaft
Spitze = Signal
Schaft=SchirmMasse
Pin 3 = zu Pin 1 gebruumlckt
Pin 3 = zu Pin 1 gebruumlckt
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
31
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
32
Digitales Audio (AESEBU)AESEBU (Protokoll AES3) ist ein ausgeglichener und uumlber einen Transformator elektrisch isolierter Eingang Er erlaubt die Benutzung von zwei Kanaumllen an einem einzigen abgeschirmten bipolaren Kabel Das gedrillte Kabel muss 3-polig sein eine Impedanz von 100 Ohm haben und mit einem XLR-Steckverbinder (AES3 Standard) abgeschirmt sein
RdnetJeder Port RDNet an Control 2 und Control 8 kann an max 32 kompatiblen Vorrichtungen die in Kaskade geschaltet sind angeschlossen werden Im nachstehenden Beispiel ist der Port der Kontrolleinheit RDNET CONTROL 2 am Eingang DATA INPUT eines AC 26N angeschlossen dessen paralleler Ausgang DATA LINK zum Eingang des naumlchsten AC26N geht Im Beispiel ist [n] eine Nummer zwischen 3 und 32 (maximale Anzahl der anschlieszligbaren Vorrichtungen an nur einem Netz)
RJ 45
|1|2|3|4|5|6|7|8|
Die Gesamtlaumlnge des Kabels CAT5 eines Unternetzes kann NICHT laumlnger als 900 Meter sein
Der Steckverbinder muss wie folgt angeschlossen sein1 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio +) 2 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio -)3 ndash Verfuumlgbar fuumlr andere Funktionen (zB analoge Masse)4 ndash digitale Masse5 ndash digitale Masse6 ndash Verfuumlgbar fuumlr andere Funktionen (zB Versorgung)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
EINSCHALTEN
Beim Einschalten der Vorrichtung startet die Initialisierung die einige Sekunden lang dauert Auf dem Display wird das Modell das Logo und der Fortschrittsbalken der Ladung des Programms angezeigt
Nach der Initialisierung erscheint auf dem Display das Menuumlfenster Meters Um die Angaben im Detail zu erfahren beziehen Sie sich bitte auf das Kapitel BESCHREIBUNG DES MENUumlFENSTERS Meters
AC26N kann jetzt benutzt werden
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
MENUrsquo PRINCIPALE
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Die sechs Menuumls im Prozessor zeigen undoder konfigurieren die Systemparameter
Anzeige der Levels der Ein- und Ausgaumlnge Anzeige des benutzten Programms und dessen Status Mute schnell
Speicherung Speicherung und Eliminierung der Systemkonfigurationen
Auswahl der Ausgaumlnge je nach Eingangssignal
Konfiguration jedes einzelnen Kanals
Konfiguration der Schnittfrequenzen und der Filtertypen fuumlr jeden einzelnen Ausgang
Zuordnung der Ein- und Ausgaumlnge Kontrast des Displays Firmware-Version Eingaumlnge und andere Optionen
Das Menuuml und die einzelnen Optionen der Anzeige koumlnnen durch Drehen des Drehgriffes FUNKTIONS SELECTOR ( ) ausgewaumlhlt werden
Die Hauptmenuumls sind
Meters
Preset
Matrix
Ch Job
X-Over
Option
Um die Auswahl zu treffen muss der gewuumlnschte Parameter auswaumlhlt und der Drehgriff Push Enter( | ) gedruumlckt werdenDas selbe Verfahren muss fuumlr die Auswahl undoder die Aumlnderung der Optionen innerhalb der Menuumlpunkte angewendet werden
BESCHREIBUNG DES MENUumlFENSTERS Meters
Diese Seite erlaubt die Konfigurationen und den allgemeinen Status der Ein- und Ausgaumlnge der benutzten Programmversion dessen Status und die Steuerung des Systems anzuzeigen
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
KONFIGURATION UND ANZEIGE
Um in das Fenster des Hauptmenuumls zu gelangen muss die Taste Menuuml ( ) auf der Frontseite der Vorrichtung gedruumlckt werdenMit der Taste ESC ( ) kehrt man von jeder Seite des Menuumls auf die vorherige Seite zuruumlck
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
33
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
34
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziertBei den digitalen Eingangssignalen entspricht die Angabe A und B dem EingangDreht man den Drehgriff FUNCTIONS SELECTOR [2] durchlaumluft man zyklisch die Ein- und Ausgangskanaumlle und die Angabe Mute allgemein (d) der ausgewaumlhlte Kanal wird hervorgehoben
b) BALKEN FUumlR DAS KOMPRESIONSLEVELMUTE KANAL
SIGNALKOMPRESSIONDie Signalkompression wird durch das Gleiten des rechten Balkens von oben nach unten angezeigt
MUTE Jeder einzelne Kanal kann auf Mute gestellt werden Den Kanal auswaumlhlen und den Drehgriff Push Enter [2] druumlcken um die Aumlnderung des Status zu bestaumltigen Die Angabe des Kanals wird durch den Buchstaben M ersetzt und der Balken wird komplett hervorgehobenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werden
c) BALKEN DES SIGNALLEVELSDie Anzeige des Levels jedes einzelnen Kanals wird durch das Gleiten des linken Balkens angezeigt
d) MUTE ALLGEMEINEs ist moumlglich alle Ein- und Ausgaumlnge gleichzeitig auf Mute zu schalten Den Drehgriff FUNCTIONS SELECTOR drehen den Buchstaben M waumlhlen und dann den Drehgriff Push Enter druumlckenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werdenDie allgemeine Stummschaltung hat eine houmlhere Prioritaumlt als die Stummschaltung der einzelnen Kanaumlle
e) ANSTEUERUNGSARTENEs wird angezeigt wie AC26N benutzt wird undoder an welchen Vorrichtungen es angeschlossen ist
= Benutzung stand-alone Kein Anschluss an einer externen Vorrichtung
= Direkt am Netz RDnet und am Computer angeschlossen
= Uumlber USB-Kabel direkt am Computer angeschlossen
f) ANZEIGE DES STATUS DER EINSTELLUNGENHier wird angezeigt ob einer oder mehrere Parameter des geladenen Programms im Vergleich zur letzten Speicherung veraumlndert wurden
Original-Programm
Programm mit veraumlnderten Parametern
g) EINGESTELLTES PROGRAMMDie Nummer zeigt das vom System geladene und benutzte Programm in Bezug auf die Lokalisierung der Speicherung an Fuumlr weitere Details beziehen Sie sich bitte auf das Menuuml Preset
Local
NET
USB
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
BESCHREIBUNG DES MENUumlFENSTERS Ch Job
Dieses Fenster erlaubt die Anzeige der Konfiguration jedes einzelnen Kanals
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) SIGNALLEVELZeigt die Signalstaumlrke an Das Ansteigen der Signalintensitaumlt wird in Dezibel (dB) ausgedruumlckt Der Parameter kann zwischen -8000 dB und +2000 dB in Schritten von 001 dB ausgewaumlhlt werden Ein Anstieg von 6 dB ist fast gleich eine Verdoppelung in linearer Skala des Spannungswertes des SignalsBei einer Staumlrke von 0 dB wird das Signal verstaumlrkt waumlhrend es ein einer Staumlrke von weniger als 0 dB abgeschwaumlcht wird
c) VERZOumlGERUNG DES SIGNALS (DELAY)Das wiedergegebene Audio-Signal kann verzoumlgert werden um die akustische Ausrichtung zu erlauben Dies gleicht die verschiedenen Positionen der Lautsprecher bei der Installation und Klangwiedergabe aus und wird in mS ausgedruumlckt Der Parameter kann zwischen 00 mS und 729 mS in Schritten von 01mS ausgewaumlhlt werden
Um ein Audiosignal auszurichten kann folgende Formel benutzt werden
Verzoumlgerung = GAPx1000)344
Verzoumlgerung = mS (in Millisekunden ausgedruumlckt)GAP = Abstand des Lautsprechers vom Referenzpunkt (in Metern ausgedruumlckt)Klanggeschwindigkeit = 344 ms
d) MUTEJeder einzelne Kanal kann auf Mute gestellt werden Derselbe Befehl kann im Fenster des Menuumls Meters aktiviert werden PS Die al lgemeine Stummschaltung hat eine houmlhere Priori taumlt als die Stummschaltung der einzelnen Kanaumlle
e) PHASEErlaubt die Phasenrotation um 180deg zum EingangssignalDiese Rotation erlaubt vor Allem die Optimierung der niederen Frequenzen bei komplexen Installationen
f) ENTZERRUNGENDieser Befehl oumlffnet das Menuumlfenster fuumlr die Entzerrung des einzelnen Kanals Er wird vor Allem benutzt um eine oder mehrere Frequenzen zu korrigieren die gedaumlmpft oder verstaumlrkt werden muumlssen
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
35
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
36
AC26N verwaltet 12 Filter fuumlr jeden einzelnen Ein- und Ausgangskanal mit drei verschiedenen Konfigurationen- Equalizer PEQ (peaking equalizer) ist ideal um nur ein bestimmtes Frequenzband
zu identifizieren zu isolieren und zu korrigieren Es gehen alle Frequenzen durch aber nur die um die mittlere Frequenz steigt und sinkt um eine bestimmte Bandbreite und eine bestimmte Staumlrke
- Equalizer High-Shelf geht alle Frequenzen durch aber die Frequenzen uumlber der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
- Equalizer Low-Shelf geht alle Frequenzen durch aber die Frequenzen unter der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
f Nummerierung der 12 verfuumlgbaren Filter fuumlr diesen Ein- oder Ausgang1
f2 Es wird der Filtertyp angezeigt
Dis Ausgeschaltet (nicht vorhanden)
PEQ Peaking equalizer
Sh H Filter High-Shelf
Sh L Filter Low-shelf
Beispiele PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
ANMERKUNGDer Parameter Bw legt das Frequenzfeld neben der eingestellten Frequenz fest wo der Filter aktiviert wird je houmlher der Bw-Wert desto houmlher das Frequenzfeld (1Bw=1 Oktave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filter High-Shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filter Low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) KOMPRESSIONDieser Befehl oumlffnet das Menuumlfenster fuumlr die Kompression des einzelnen Kanals
g1) TresholdIdentifiziert die Schwelle an der das Kompressionsverhaumlltnis beginnt Der Basiswert 11
g2) RatioIdentifiziert das Kompressionsverhaumlltnis zwischen dem Ein- und Ausgangssignal
g3) Post Gain Attach Release HoldDiese Daten entsprechen dem Kompressionsverhaumlltnis das man erreichen moumlchte
Post Gain ist der Gewinn am AusgangAttack ist die Anschlusszeit Release ist die ReleasezeitHold ist die Beibehaltungszeit
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
BESCHREIBUNG DES MENUumlFENSTERS Preset
Dieses Fenster erlaubt bis zu 32 Konfigurationen im AC26N zu speichernDer Hersteller liefert das System mit einem voreingestellten Programm das auf Position 0 gespeichert ist und nicht uumlberschrieben werden kann
032 Es zeigt die Lokalisierung der Speicherung der KonfigurationDiese Nummer erscheint auch im Fenster Meters auf der Position (g) Das benutzte Programm kann jederzeit vom Benutzer angezeigt werden
Empty Preset Es ist der Name der der Nummer der Lokalisierung zugeordnet wird wenn keine Einstellung gespeichert ist (leer)
Local preset Es i s t de r Name de r de r Nummer de r Loka l i s i e rung zugeordnet wird wenn eine Konfiguration gespeichert wird
ANMERKUNG = Man kann eine Einstellung mit dem gewuumlnschten Namen mit max 16 Buchstaben nur speichern wenn man die Schnittstelle uumlber den Computer benutzt
Bei der Wahl eines Programms erscheint folgendes Fenster
Anzeige des Namens der dem Programm zugeordnet istUm auf die Anwendung einzuwirken stehen 3 Auswahlmoumlglichkeiten zur Verfuumlgung
Das Programm wird im Speicher des AC 26N gespeichert
Das Programm wird geloumlscht
Das Programm wird geladen und ist bereit fuumlr die Benutzung
Save
Del
Load
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
37
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
38
BESCHREIBUNG DES MENUumlFENSTERS X-Over
Dieses Fenster erlaubt fuumlr jeden Ausgang einen Bassdurchgangsfilter einen Hochdurchgangsfilter oder mittels Kombination von beiden einen Banduumlbergangsfilter zu waumlhlenDer Filter ist ein Linkwitz-Riley wo man die Neigung von 12 dBoct 24dBoct oder 48 dBoct und die entsprechende Schnittfrequenz auswaumlhlen kann
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) AUSGANGSKANAumlLE
Die Steckverbinder am Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) FILTER CROSSOVERDen Filter nach Bedarf waumlhlen Man kann folgendes auswaumlhlen
Dis Kein Filter aktiviert
HP Hochdurchgangsfilter nur den Teil des Audiosignals durchlassen der uumlber der Schnittfrequenz liegt
LP Bassdurchgangsfilter nur den Teil des Audiosignals durchlassen der unter der Schnittfrequenz liegt
Filter-Konfiguration Tiefpass Hochpass
Nichts Dis Dis
Hochpass HP Dis
Tiefpass Dis LP
Bandpass HP LP
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
c) DAumlMPFUNGSNEIGUNGDie Daumlmpfungsneigung des Audiosignals auf der Basis der Verringerung auswaumlhlen die man erreichen moumlchte Je houmlher die Daumlmpfungsneigung bei gleicher Schnittfrequenz desto groumlszliger ist die Signalauswahl Man kann folgendes waumlhlen
12 entsprechend 12 dboct
24 entsprechend 24 dboct
48 entsprechend 48 dboct
d) SCHNITTFREQUENZErlaubt die Durchgangsfrequenz der niederen Frequenzen (Bassdurchgangsfilter) oder der hohen Frequenzen (Hochdruchgangsfilter) einzustellenDie Auswahl des Schnitts bezieht sich auf die Wiedergabe die man erreichen moumlchteDie benutzte Maszligeinheit ist Hz
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
BESCHREIBUNG DES MENUumlFENSTERS Matrix
Erlaubt fuumlr jeden Ausgang das Eingangssignal zu waumlhlen das als Quelle benutzt werden soll
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) AUSGANGSKANAumlLEIdentifizierung des einzustellenden Ausgangskanals
b) IDENTIFIZIERUNG DER EINGAumlNGEDen Signaltyp auswaumlhlen der nach eigener Anforderung jedem einzelnen Ausgang zugeordnet werden soll Man kann folgendes waumlhlen
In A Das Signal wird dem Eingang A zugeordnet
In B Das Signal wird dem Eingang B zugeordnet
In A+B Zuordnung der a lgebra ischen Summe der be iden Eingangssignale A und B
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
BESCHREIBUNG DES MENUumlFENSTERS Option
Erlaubt die Anzeige der Systemeinstellungen wie die Zuordnung der Ein- und Ausgaumlnge Daumlmpfung Displaykontrast und Firmware-Version
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B Src
Diese Option erlaubt die Einstellung des Audio-Signaltyps am Eingang
Analoge Audiosignale (Eingaumlnge A und B)
Digitale Audiosignale (Eingang AESEBU)
DigOut Src
An In =Audiosignale an den analogen Eingaumlngen
Dig In =Audiosignale am digitalen Eingang
OUT 1-2 =Audiosignale an den Ausgaumlngen 1 und 2
OUT 3-4 =Audiosignale an den Ausgaumlngen 3 und 4
OUT 5-6 =Audiosignale an den Ausgaumlngen 5 und 6
Input Mode
An In
Dig In
Indip =
Linked =
Diese Option erlaubt die Audioquelle zu waumlhlen die fuumlr den Steckverbinder AESEBU OUT (digitaler Ausgang) bestimmt ist
Erlaubt die Eingaumlnge zu konfigurieren
Sie sind unabhaumlngig und selbststaumlndig sie unterliegen keinen Verpflichtungen untereinander Sie sind verbunden und funktionieren im Stereo-Modus
Die Kompressoren Filter Verzoumlgerungen die Lautstaumlrke sind bei beiden Kanaumllen identisch
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
39
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
40
Atten PadZeigt an wie der Wahlschalter -6 dB auf der Ruumlckseite eingestellt ist [Ref 5] Dieser Wahlschalter muss aktiviert werden wenn das Level an den analogen Eingaumlngen zu hoch ist Der Wahlschalter wird uumlber die Taste aktiviert im Menuuml gibt es nur eine Anzeige
0dB = Wahlschalter nicht aktiviert
-6dB = Wahlschalter aktiviert
Contrast
10 heller 60 dunkler 100
Fw Vers
Die Eingangssignale sind dieselben wie die Eingangsquelle
Die Eingangssignale werden vom internen Prozessor um -6 dB gedaumlmpft
Erlaubt den Kontrast des LCD-Displays einzustellen um den Unterschied der Helligkeit auf den Installationsort auszurichten Ein deutlicheres Display erlaubt auf korrekte und schnelle Weise innerhalb der Menuumls zu surfenDie Hersteller-Einstellung am Ausgang liegt bei 60
Zeigt die Firmware-Version des Prozessors an
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
41
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
42
TECHNISCHE DATEN
Antwort in FrequenzDynamische GammaCMMRCrosstalkDistorsion
ProzessorFrequenz der DatenausarbeitungAnaloge Converter Verzoumlgerung der VerteilungSpeicherung der Konfigurationen
DisplayTastenBedienungen
Analoger Eingang ndeg2 x XLR (3-poliger Female Stecker)Impedanz des Eingangs gt10KOhmMaximales Level +21dBu ohne PAD
+27dBu bei PAD
Impedanz des Ausgangs 50OhmMaximales Level +21dBu Typ symmetrisch
Typ SPDIF-AESEBU (AES3)
Typ Entsprechend dem Standard des Eingang
Typ
Typ
NETZSPANNUNGABMESSUNGEN (BXHXT)GEWICHT
AUDIO-LEISTUNGEN+- 01dB (20 to 30kHz)116dB typgt 60dB (50 to 10kHz)lt -100dB0002 (1kHz +4dBu)
DIGITALE AUDIO-LEISTUNGEN DSP 2856-bit 48KHz24-bit BURR BROWN15ms32 preset
KONTROLLEN LCD GrafikESC - MENU - FUNCTIONS SELECTIONENTER
EIN-AUSGAumlNGE
Analoger Ausgang ndeg6 x XLR (3-poliger Male Stecker)
Digitaler Eingang ndeg1x XLR (3-poliger female Stecker)
Digitaler Ausgang ndeg1x XLR (3-poliger Male Stecker)
Ein-Ausgang Rdnet ndeg2 x XLR RJ45 (kabel CAT 5) USB Typ B
KONTROLLPARAMETER AUDIOStaumlrke -80dB a +20dB step 01dBVerzoumlgerung Eingang 0 a 729mS step 01 mS
Ausgang 0 a 340mS step 01mSPhasenrotation 0deg - 180deg
KOMPRESSIONSchwelle -80dB a +20dB step 01dBVerhaumlltnis 11 a Inf1 step 001Staumlrke am Ausgang 0dB a 40dB step 01dBAnschlusszeit 1mS a 1000mS step 01mSReleasezeit 1mS a 1000mS step 01mSBeibehaltungszeit 1mS a 1000mS step 01mS
EQUALIZER12 Equalizer fuumlr jeden Ein- und Ausgang
PEQ (parametrischer) Hi-shelf Lo-sheftFrequenz 20Hz a 20KHz step 1HzStaumlrke -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (lediglich PEQ)
FILTER CROSSOVERFilter Linkwitz Riley
HP HochdurchgangsfilterLP Bassdurchgangsfilter
Neigung 12dBoct - 24dBoct - 48dBoctSchnittfrequenz 5Hz a 20KHz step 1Hz
Full-range 100-240Vac 50-60Hz430482x43x130mm 19Kg
AnmerkungenSpezifikationen unterliegen Aumlnderungen ohne Vorankuumlndigung
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
INTRODUCTIONAC26N est un processeur audio numeacuterique pour la gestion de leacutequipement audio conccedilu pour des installations fixes et mobiles Il fonctionne selon une technologie de pointe avec des processeurs agrave 2856bits et des convertisseurs ADDA agrave 24-bits hautes performances Les fonctions du processeur sont les niveaux dentreacutee et de sortie le deacutelai (delay) la polariteacute 12 bandes deacutegalisation par canal dentreacutee et de sortie diffeacuterentes seacutelections de croisement (crossover) et un limiteur hautes performances Le controcircle des filtres a une reacutesolution de 1Hz Les entreacutees et les sorties peuvent ecirctre programmeacutees en plusieurs configurations pour satisfaire tous les besoins AC26N peut ecirctre controcircleacute en temps reacuteel et tous les paramegravetres peuvent ecirctre configureacutes depuis le pupitre frontale et par ordinateur avec interface graphique intuitive accessible via le logiciel laquoDVA Networkraquo et une connexion de reacuteseau deacutedieacutee RDnet ou USBLa mise agrave jour du logiciel pour lUniteacute centrale et DSP par ordinateur portable permet de maintenir le dispositif actualiseacute Il est possible denregistrer et de rappeler 32 configurations preacute-eacutequipeacutees de configuration
Contenu de lemballage - AC26N - Mode demploi- CD logiciel- Cacircble dalimentation
Caracteacuteristiques- 2 entreacutees et 6 sorties avec adressage flexible- Entreacutee et sortie steacutereacuteo AESEBU adressables - DSP 2856-bit- Convertisseurs AD BURR BWOWN 24-bit hautes performances- Freacutequence de reacutesolution des filtres 1 Hz - 12 eacutegaliseurs parameacutetriques pour chaque entreacutee et sortie- 2 filtres de croisement par sortie avec pente seacutelectionnable agrave 122448dBoct- DRC agrave configuration multiple hautes performances pour configuration limiteur
compression pour chaque entreacutee et sortie- Niveau reacuteglable en dB polariteacute et deacutelai pour chaque entreacutee et sortie- Mise agrave jour du micrologiciel par lordinateur- Affichage graphique agrave cristaux liquides- 32 preacutereacuteglages enregistrables par lutilisateur- Interface USB pour le controcircle et la configuration par ordinateur- Interface RDnet permettant de controcircler jusquagrave 256 dispositifs agrave distance
PC
PC
RDNETcontrol(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FONCTIONS DE LA FACE AVANT
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
COMMANDES ET FONCTIONS1) AFFICHAGE
Laffichage graphique agrave cristaux liquides permet de visualiser et deacutediter les informations de lAC26N sans utiliser lordinateur Le contraste peut ecirctre configureacute dans le menu principal
2) MANETTE Functions Selector et Push EnterCe controcircle permet de se deacuteplacer de seacutelectionner et de modifier les paramegravetres dans les menus affichables agrave leacutecranRotation de la manette (Functions Selectors)- permet de se deacuteplacer sur les diffeacuterentes pages du menu - permet de modifier les paramegravetres seacutelectionneacutesPression de la manette (Push Enter)- permet de seacutelectionnervalider les paramegravetres
3) Bouton ESC Ce controcircle permet de quitter les menus afficheacutes ou de revenir agrave la visualisation preacuteceacutedente
4) Bouton Menu Ce controcircle permet dacceacuteder directement au menu principal
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
Fra
nccedilais
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
43
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
Fra
nccedilais
44
DVA Network
AC26N est eacutequipeacute dune interface de reacuteseau proprieacutetaire deacutenommeacutee RDNET au moyen de laquelle il est possible de sinterfacer agrave lordinateur agrave travers un peacuteripheacuterique (RDNET control)
Pour cela un protocole de communication a eacuteteacute deacuteveloppeacute avec lequel il est possible de recevoir et denvoyer les donneacutees ce branchement permet de faire le monitorage en temps reacuteel des paramegravetres du diffuseur comme puissance de sortie tempeacuterature de lamplificateur eacutetat du limiteur etc Il est aussi possible de seacutelectionner diffeacuterentes eacutegalisations ou den creacuteer de nouvelles et de reacutegler les niveaux de volume souhaiteacutes au moyen dun plug-in approprieacute
On conseille de teacuteleacutecharger gratuitement le logiciel DVA Network directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
DVA USB Manager
On conseille de teacuteleacutecharger gratuitement le logiciel DVA USB Manager directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
Le micrologiciel du module amplificateur peut ecirctre remis agrave jour par le port USBPour rendre cette mise agrave jour possible et facile un programme speacutecifique a eacuteteacute deacuteveloppeacute
DOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
CONNEXIONS DU PANNEAU ARRIEgraveRE
1586 75 141210 11 13 169 17
14) Connecteur ldquo USBrdquoCe connecteur USB (type B) permet de connecter le processeur agrave un ordinateur pour le controcircle et la mise agrave jour du micrologiciel via un programme deacutedieacute (DVA Network)
15) PRISE DALIMENTATION MAINSPermet la connexion du cacircble dalimentation fourni de seacuterie
16) PORTE-FUSIBLE FUSELogement pour fusible de ligne
17) INTERRUPTEUR GENERAL POWERLinterrupteur permet de mettre en marche ou deacuteteindre le controcircleur audio
COMMANDES ET FONCTIONS
5) SELECTEUR ldquo-6dBrdquoLe seacutelecteur permet de reacuteduire de 6dB les niveaux dentreacutee analogiques XLR [6] tout en compensant les niveaux eacuteleveacutes de sortie des meacutelangeurs ou dautres dispositifs audio Quand la barre du niveau de signal des entreacutees sur laffichage [1] reste au maximum cela indique que le niveau du signal entrant est eacuteleveacute Il est alors conseilleacute dutiliser latteacutenuation -6dBIl est possible de veacuterifier quand le seacutelecteur est activeacute par le menu Option
6) CONNECTEURS DENTREE ldquoArdquo ET ldquoBrdquoEntreacutees eacutequilibreacutees au niveau de la ligneIls sont en mesure daccepter des connecteurs XLR macircles
7) CONNECTEURS DE SORTIE ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo ET ldquo6rdquoSorties eacutequilibreacutees au niveau de la ligne Ils sont en mesure daccepter des connecteurs XLR femelles
Prendre garde agrave brancher convenablement les sorties sur les diffuseurs ou les amplificateurs en fonction des configurations de chaque canal pour eacuteviter des deacutegacircts et des problegravemes de fonctionnement
Section ldquoAESEBUrdquo
8) CONNECTEUR DENTREE INOutre les entreacutees audio analogiques une entreacutee audio numeacuterique SPDIF-AESEBU (AES3) a eacuteteacute preacutevue et peut ecirctre seacutelectionneacutee par le menu de setupLentreacutee requiert une connexion eacutequilibreacutee en utilisant un connecteur XLR avec un cacircble agrave 3 conducteurs de 110ohm torsadeacute
9) CONNECTEUR DE SORTIE OUTCe connecteur permet de relancer le signal audio dans les entreacutees analogiques ou numeacuteriques ou sur les sorties La source doit ecirctre reacutegleacutee par le menu OptionLa connexion sera conforme agrave la mecircme norme que lentreacutee [reacutef8]
Section ldquoRDNETrdquo
10) CONNECTEUR DENTREE DATA INPUTConnecteur RJ45 entreacutee de donneacutees
11) CONNECTEUR DE SORTIE DATA LINKConnecteur RJ45 sortie de donneacutees pour la connexion de seacuterie en cascade
12) VOYANT LUMINEUX ONCe voyant de couleur verte sallume uniquement quand lAC26N a reconnu et est connecteacute agrave luniteacute principale RDNET par lordinateur
13) VOYANT LUMINEUX ACTIVECe voyant de couleur jaune clignote quand une transmission des donneacutees est active entre RDNET et le dispositif
PUSH
P SHU
SHPU
P SHU
PUSH
CONNEXIONS
Audio analogiquesLes connexions eacutequilibreacutees permettent de reacuteduire au minimum le bruit provoqueacute par les cacircbles et dutiliser de longs cacircblesCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLe connecteur XLR doit ecirctre brancheacute avec la broche 1 agrave la masse la broche 2 au chaud (+) et la broche 3 au froid (-) En cas de cacircble blindeacute brancher le blindage agrave la broche 1Les cacircbles de connexion XLR-XLR et XLR-Jack14(63mm) peuvent semployer pour la connexion agrave lAC26N
12
3
Entreacutee
Entreacutee
XLR - femme
XLR - femme
1 2
3
Sortie
Sortie
XLR - Macircle
XLR - Macircle
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2 = Point chaudPhase +VE
Broche 3 =Point froidPhase -VE
Broche 3 =Point froidPhase -VE
Anneau
Manchon
Pointe Point chaudPhase +VE
Anneau = Point froidPhase -VE
ManchonB Masselindeacute
Pointe
Les connexions deacuteseacutequilibreacutees peuvent semployer mecircme si le bruit provoqueacute par les cacircbles augmente Les cacircbles ne peuvent deacutepasser 5m de longCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLes connexions deacuteseacutequilibreacutees peuvent abaisser le niveau du signal entrant de 6dB Pour remeacutedier agrave cet inconveacutenient il faut brancher la broche 3 agrave la masse mecircme si cela augmente le bruit
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
45
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
46
12
3
1 2
3
Pointe Manchon
Pointe = Signal
Broche 3 = Link to Pin 1
Broche 3 = Link to Pin 1
ManchonB Masselindeacute
Audio numeacuteriques (AESEBU)
AESEBU (protocole AES3) est une entreacutee eacutequilibreacutee isoleacutee eacutelectriquement agrave laide dun transformateur Elle permet demployer deux canaux audio dans un seul cacircble bipolaire blindeacute Les caracteacuteristiques du cacircble doivent ecirctre de 3 pocircles impeacutedance 100ohm torsadeacute et blindeacute avec connecteur XLR (AES3 standard)
RJ 45
|1|2|3|4|5|6|7|8|
RDnet
Chaque port RDNet des Control 2 et Control 8 peut ecirctre brancheacute agrave un maximum de 32 dispositifs compatibles placeacutes en cascade Dans lexemple suivant le port de luniteacute de controcircle RDNET CONTROL 2 est relieacute agrave lentreacutee DATA INPUT dun AC26N dont la sortie parallegravele DATA LINK est envoyeacutee agrave lentreacutee de lAC26N successif Dans lexemple [n] est un nombre compris entre 3 et 32 (limite maximale des dispositifs que lon peut relier agrave un sous-reacuteseau)
La longueur totale du cacircble CAT5 dun sous-reacuteseau NE peut PAS deacutepasser 900 megravetres
Le connecteur doit ecirctre relieacute comme 1 ndash disponible pour dautres fonctions (par exemple audio +) 2 ndash disponible pour dautres fonctions (par exemple audio )3 ndash disponible pour dautres fonctions (par exemple masse analogique)4 ndash masse numeacuterique5 ndash masse numeacuterique6 ndash disponible pour dautres fonctions (par exemple alimentation)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
MISE EN MARCHE
Lors de la mise en marche du dispositif linitialisation deacutebute et dure quelques secondes Leacutecran affiche le modegravele le logo et la barre de progression du chargement du programme
En fin de processus dinstallation leacutecran affiche la fenecirctre du menu Meters Pour connaicirctre les indications en deacutetail consulter le paragraphe DESCRIPTION FENETRE MENU Meters
LAC26N est precirct agrave lemploi
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION ET VISUALISATION
Pour entrer dans la fenecirctre du menu principal il faut pousser sur la touche MENU ( ) agrave lavant du dispositifDune page quelconque du menu en poussant sur la touche ESCrdquo ( ) on revient automatiquement sur la page-eacutecran preacuteceacutedente
MENU PRINCIPAL
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Le processeur contient six menus Ils montrent etou configurent les paramegravetres du systegravemeLes menus principaux sont
Meters Visualisation des niveaux des entreacutees et des sorties visualisation du programme utiliseacute et eacutetat mute rapide
Preset Meacutemoriser enregistrer et eacuteliminer les configurations du systegraveme
Matrix seacutelectionner les sorties en fonction du signal entrant
Ch Job configuration de chaque signal
X-Over configurer les freacutequences de coupure et les types de filtres pour chaque sortie
Option attribution des entreacutees et des sorties contraste daffichage la version du micrologiciel les entreacutees et dautres options
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
47
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
48
DESCRIPTION DE LA FENETRE MENU Metersrdquo
Cette fenecirctre permet de visualiser les configurations et leacutetat geacuteneacuteral des entreacutees et des sorties la version du programme utiliseacute son eacutetat et le mode de pilotage du systegraveme
Les menus et les options afficheacutees peuvent se seacutelectionner en tournant la manette ldquoFUNCTIONS SETECTORrdquo ( ) Pour avoir accegraves agrave linteacuterieur de la seacutelection il faut mettre le paramegravetre souhaiteacute en eacutevidence et pousser sur la manette ldquoPush Enterrdquo ( | ) Il faut en faire de mecircme pour seacutelectionner etou modifier les options dans les commandes du menu
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositifAvec des signaux dentreacutee numeacuteriques les indications ldquoArdquo et ldquoBrdquo correspondent agrave lentreacuteeEn tournant la manette ldquoFUNCTIONS SELECTORrdquo [2] on fait deacutefiler en mode cyclique les canaux dentreacutee de sortie et lindication de mute geacuteneacuteral (d) le canal seacutelectionneacute est mis en eacutevidence
b) BARRE DE NIVEAU DE COMPRESSIONMUTE CANAL
COMPRESSION DE SIGNALLa compression du signal est visualiseacutee par le deacutefilement de la barre de droite de haut en bas
MUTE Chaque canal peut ecirctre placeacute en mute Seacutelectionner le canal et pousser sur la manette ldquoPush Enterrdquo [2] pour valider le changement deacutetat Lindication du canal sera remplaceacutee par la lettre M et la barre sera totalement mise en eacutevidencePour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterations
c) BARRE DE NIVEAU DE SIGNALLindication du niveau de chaque canal est signaleacutee par le deacutefilement de la barre de gauche
d) MUTE GENERALIl est possible de mettre simultaneacutement toutes les entreacutees et les sorties en mute Tourner la manette ldquoFUNCTIONS SELECTORrdquo seacutelectionner la lettre M et pousser sur la manette Push EnterPour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterationsLe mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) MODES DE COMMANDEIl affiche le mode dutilisation etou les dispositifs qui sont relieacutes agrave lAC26N
Local = utilisation autonome Aucune connexion agrave un dispositif exteacuterieur
NET = relieacute directement au reacuteseau deacutedieacute RDNet et agrave lordinateur
USB = relieacute directement agrave un ordinateur par cacircble USB
f) INDICATION DETAT DE PARAMETRAGECette indication permet de constater si un ou plusieurs paramegravetre(s) du programme chargeacute aont eacuteteacute modifieacute(s) par rapport au dernier sauvetage
= programme dorigine
= programme avec des paramegravetres modifieacutes
g) PROGRAMME CONFIGURELe chiffre indique le programme chargeacute et utiliseacute par le systegraveme agrave lemplacement de sauvetage Consulter le menu de Preset pour de plus amples deacutetails
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
DESCRIPTION DE LA FENETRE MENU Ch Job
Cette fenecirctre permet dafficher la configuration de chaque canal
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) NIVEAU DU SIGNALIndique le gain du signal Laugmentation de lintensiteacute dun signal est libelleacutee en deacutecibel (dB) Le paramegravetre peut ecirctre seacutelectionneacute de -8000dB agrave +2000dB avec des pas de 001dB Une augmentation de 6dB est eacutegale approximativement au redoublement agrave leacutechelle lineacuteaire du niveau du signal sous tensionAvec un gain supeacuterieur agrave 0dB le signal est amplifieacute tandis quavec un gain infeacuterieur agrave 0dB le signal est atteacutenueacute
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
49
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
50
c) DELAI DU SIGNAL (DELAY)Le signal audio reproduit peut ecirctre retardeacute pour permettre lalignement acoustique Cela compense les diffeacuterentes positions des diffuseurs pendant linstallation et la reproduction sonore Il se libelle en mS Le paramegravetre peut ecirctre seacutelectionneacute de 00mS agrave 729mS avec un pas de 01mSPour aligner un signal audio il est possible dutiliser la formule suivante
Deacutelai = (GAPx1000)344
Deacutelai = ms (en millisecondes)GAP = distance du diffuseur du point de reacutefeacuterence (en megravetres)Vitesse du son = 344ms
d) MUTEChaque canal peut ecirctre placeacute en mute La mecircme commande peut ecirctre activeacutee dans la fenecirctre du menu meters NB Le mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) PhasePermet la rotation de phase de 180deg par rapport au signal entrantCette rotation permet loptimisation surtout des basses freacutequences dans les installations complexes
f) EGALISATIONCette commande ouvre la fenecirctre du menu deacutegalisation de chaque canal Elle sert surtout pour corriger une ou plusieurs freacutequences qui doivent ecirctre atteacutenueacutees ou augmenteacutees
M M
LAC26N gegravere 12 filtres par canal dentreacutee et sortie avec trois types de configurations diffeacuterentes - Leacutegaliseur PEQ (peaking equalizer) est ideacuteal pour identifier isoler et
corriger une seule plage de freacutequences bien deacutetermineacutee Toutes les freacutequences passent mais il augmente ou diminue uniquement celles autour de la freacutequence centrale pour une bande preacutecise et un gain deacutefini
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessus de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessous de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
f Numeacuterotation des 12 filtres disponibles pour cette entreacutee ou cette sortie1
f Le type de filtre est afficheacute 2
Dis Deacutesactiveacute (absent)
PEQ Peaking equlizer
Sh H Filtre high-shelf
Sh L Filtre high-shelf
Exemples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
REMARQUELe paramegravetre Bw deacutetermine le champ de freacutequences adjacent agrave la freacutequence configureacutee ougrave est activeacute le filtre Plus la valeur Bw est eacuteleveacutee plus vaste est le champ de freacutequences (1Bw=1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONCette commande ouvre la fenecirctre du menu de compression de chaque canal
g1) TresholdIdentifie le seuil ougrave commence le rapport de compression La valeur de base 11
g2) RatioIndique le rapport de conversion entre le signal entrant et le signal sortant
g3) Post Gain Attach Release HoldCes donneacutees deacutependent du rapport de conversion que lon veut obtenir - Post Gain est le gain de sortie- Attack est le temps dattaque - Release est le temps de relacircchement- Hold est le temps de maintien
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
52
DESCRIPTION DE LA FENETRE MENU Preset
Cette fenecirctre permet de meacutemoriser jusquagrave 32 configurations dans lAC26NLe fabricant fournit le systegraveme avec un programme configureacute et enregistreacute en position 0 et non susceptible deacutecrasement
032 Elle indique lemplacement de sauvetage de la configurationCe numeacutero apparaicirct dans la fenecirctre Meters en position (g) A tout moment le programme utiliseacute peut ecirctre afficheacute par lutilisateur
Empty Preset Cest le nom qui est associeacute au numeacutero de lemplacement quand aucune configuration (vide) nest enregistreacutee
Local preset Local preset est le nom qui est associeacute au numeacutero de lemplacement quand on enregistre une configuration NB = Il est possible denregistrer une configuration avec lenom souhaiteacute de 16 lettres tout au plus agrave condition que lonutilise linterface via lordinateur
Le nom du programme assigneacute est indiqueacutePour toucher agrave lapplication 3 choix soffrent agrave vous
Save Le programme est enregistreacute en meacutemoire de lAC26N
Del Le programme est effaceacute
Load Le programme est chargeacute et precirct agrave lemploi
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
51
DESCRIPTION DE LA FENETRE MENU X-Over
Cette fenecirctre permet de seacutelectionner un filtre passe bas un filtre passe haut ou par la combinaison des deux de creacuteer un filtre passe bande pour chaque sortieLe filtre actif est un Linkwitz-Riley qui permet de seacutelectionner la pente de 12dBoct 24dBoct ou 48dBoct et sa freacutequence de coupure
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) CANAUX DE SORTIE
Les connecteurs de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) FILTRE CROSSOVERSeacutelectionner le filtre selon les besoins Il est possible de seacutelectionner
Dis Aucun filtre activeacute
HP Filtre passe-haut laisse passer uniquement la partie de signal audio supeacuterieure agrave la freacutequence de coupure
LP Filtre passe-bas laisse passer uniquement la partie de signal audio infeacuterieure agrave la freacutequence de coupure
Configuration du filtre Passe-haut Passe-bas
Rien Dis Dis
Passe-haut HP Dis
Passe-bas Dis LP
Passe-bande HP LP
12dBoct
24dBoct
Hz
dB
Ga
in 48dBoct
12dBoct
24dBoct
Hz
dB
Ga
in
48dBoct
c) PENTE DATTENUATIONSeacutelectionner la pente datteacutenuation du signal audio en fonction de la diminution que lon veut obtenir Plus la pente datteacutenuation est eacuteleveacutee agrave eacutegaliteacute de freacutequence de coupure plus eacuteleveacutee sera la seacutelection du signal Il est possible de seacutelectionner
12 correspond agrave 12dboct
24 correspond agrave 24dboct
48 correspond agrave 48dboct
d) FREQUENCE DE COUPUREElle permet de reacutegler la freacutequence de passage des freacutequences infeacuterieures (filtre passe-bas) ou des freacutequences supeacuterieures (filtre passe-haut) uniquementLe choix de la coupure deacutepend de la reproduction que lon veut obtenirLuniteacute de mesure utiliseacutee est lHz
Hz
Hz
dB
dB
Ga
in
f0
f0
0dB0dB
0dB
-6dB
freacutequence
freacutequence
freacutequence
freacutequence
Ga
in
f0
0dB
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
53
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
54
DESCRIPTION DE LA FENETRE MENU Matrix
Elle permet de seacutelectionner le signal entrant agrave utiliser comme source pour chaque sortie
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) CANAUX DE SORTIEIdentification du canal sortant agrave reacutegler
b) IDENTIFICATIONS DES ENTREESSeacutelectionner le type de signal agrave associer agrave chaque sortie en fonction des besoins Il est possible de seacutelectionner
In A Le signal entrant A est associeacute
In B Le signal entrant B est associeacute
In A+B La somme algeacutebrique des deux signaux entrants A et B est associeacutee
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
DESCRIPTION DE LA FENETRE MENU Option
Permet dafficher les reacuteglages du systegraveme comme lassignation des entreacutees et des sorties latteacutenuation le contraste de laffichage et la version du logiciel
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcCette option permet de reacutegler le type de signal audio entrant
An In =signaux audio analogiques (entreacutees ldquoArdquo et ldquoBrdquo)
Dig In =signaux audio numeacuteriques (entreacutee AESEBU)
DigOut SrcCette option permet de seacutelectionner la source audio qui sera adresseacutee sur le connecteur AESEBU OUT (sortie numeacuterique)
An In = signaux audio des entreacutees analogiques
Dig In =signaux audio sur lentreacutee numeacuterique
OUT 1-2 = signaux audio sur les sorties 1 et 2
OUT 3-4 = signaux audio sur les sorties 3 et 4
OUT 5-6 = signaux audio sur les sorties 5 et 6
Input ModePermet de configurer les entreacutees
Indip = sont indeacutependantes et autonomes Ne sont soumises agrave aucun type de lien
Linked = sont unies et fonctionnent en mode steacutereacuteo Les compresseurs les filtres les deacutelais le volume sont identiques pour les deux canaux
Atten PadIndique le mode de reacuteglage du seacutelecteur ldquo-6dBrdquo placeacute agrave larriegravere [reacutef 5] Il faut activer ce seacutelecteur quand les niveaux dentreacutee analogiques sont trop eacuteleveacutes Le seacutelecteur sactive uniquement par le bouton Dans le menu il sagit dune simple visualisation
0dB = seacutelecteur non activeacute Les signaux dentreacutee sont identiques agrave la source entrante
-6dB = seacutelecteur activeacute Les signaux entrants sont atteacutenueacutes de -6dB par le processeur interne
ContrastIl permet de reacutegler le contraste de laffichage agrave cristaux liquides pour compenser la diffeacuterence de luminositeacute avec le lieu dinstallation Une plus grande clarteacute de laffichage permet de naviguer convenablement et rapidement dans les menusLe reacuteglage agrave la sortie de lusine du fabricant est de 60
10 plus clair 60 plus fonceacute 100
Fw VersIndique la version du logiciel du processeur
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
55
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
56
DONNES TECHINIQUES
PERFORMANCES AUDIOReacuteponse en freacutequence +- 01dB (20 to 30kHz)Plage dynamique 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsion 0002 (1kHz +4dBu)
PERFORMANCES AUDIO NUMERIQUES Processeur DSP 2856-bit Freacutequence de traitement des donneacutees 48KHzConvertisseurs analogiques 24-bit BURR BROWNDeacutelai de propagation 15msMeacutemorisations des configurations 32 preset
CONTROLES Affichage LCD graficoBoutonsCommandes ESC - MENU - FUNCTIONS SELECTION
ENTERENTREESSORTIESEntreacutee analogique ndeg2 x XLR (3 broches femelle)
Impeacutedance dentreacutee gt10KOhmNiveau maximum +21dBu senza PAD
+27dBu con PADSortie analogique ndeg6 x XLR (3 broches macircle )
Impeacutedance de sortie 50OhmNiveau maximum +21dBuType Balanceacute
Entreacutee numeacuterique ndeg1x XLR (3 broches femelle)Type SPDIF-AESEBU (AES3)
Sortie numeacuterique ndeg1x XLR (3 broches macircle )Type conforme agrave la norme de lentreacutee
EntreacuteesSortie Rdnet ndeg2 x XLR RJ45 (cacircble CAT 5)USB Type B
PARAMETRES DE CONTROLE DU SONGain -80dB a +20dB eacutetape 01dBDeacutelai Entreacutee 0 a 729mS eacutetape 01 mS
Sortie 0 a 340mS eacutetape 01mSRotation de phase 0deg - 180deg
COMPRESSIONSeuil -80dB a +20dB eacutetape 01dBRapport 11 a Inf1 eacutetape 001Gain agrave la sortie 0dB a 40dB eacutetape 01dBTemps dattaque 1mS a 1000mS eacutetape 01mSTemps de relacircchement 1mS a 1000mS eacutetape 01mSTemps de maintien 1mS a 1000mS eacutetape 01mS
EGALISEURS12 eacutegaliseurs pour chaque entreacutee et sortieType PEQ (parameacutetrique) Hi-shelf Lo-sheft
Freacutequence 20Hz a 20KHz eacutetape 1HzGain -30dB a +15dB eacutetape 001dBBande 005dB a 2dB eacutetape 001dB (uniquement pour PEQ)
FILTRES CROSSOVERFiltre Linkwitz Riley
Type HF high-shelfLF low-shelf
Pente 12dBoct - 24dBoct - 48dBoctFreacutequence de coupure 5Hz a 20KHz eacutetape 1Hz
ALIMENTATION Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)POIDS 19Kg
Remarques Speacutecifications sujettes agrave modifications sans preacuteavis
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
2 VIE ATTIVO2 WAY ACTIVE
3 VIE PASSIVO3 WAY PASSIVE
L
L
A
A
HIGH L
MID L
LOW HIGHMID RHIGHMID L
LOW L
HIGH R
MID R
LOW R
R
R
B
B
1
1
2
2
3
3
456
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
Menu Matrix configurationMatrix
57 58
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
EROUIG ATRIX TNM
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
OU
TP
UT
1
OU
TP
UT
2
OU
TP
UT
3
OU
TP
UT
4
OU
TP
UT
5
OU
TP
UT
6
AE
S-E
BU
OU
TP
UT
INP
UT
A
AE
S-E
BU
INP
UT
INP
UT
B
D D D D D D
D D
A A A A A A
A SA
MP
LE
RA
TE
CO
NV
A
LIN
KA
BL
E
SC
HE
MA
A B
LO
CC
HI -
BL
OC
K D
IAG
RA
MB
LO
CK
SC
HA
LT
BIL
D -
SC
HE
MA
S F
ON
CT
ION
NE
LS
LINE ARRAY SUB MONO ATTIVO
LINE ARRAY SUB MONO ACTIVEINGRESSI - INPUT
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
L
L
L
A
A
A
AESEBU IN
AESEBU IN
AESEBU IN
AESEBU OUT
AESEBU IN
AESEBU IN
AESEBU OUT
R
R
R
LR
B
B
B
123456
HIGHMID L
HIGHMID L HIGHMID R
HIGHMID R
LOW L LOW R
LAYER
DISPLAY MEMORY
FADER MODE
LAYER
DISPLAY MEMORY
FADER MODE
Ingresso ANALOGICO
ANALOG Input
Collegamento in cascata
Link connections
Ingresso DIGITALE
DIGITAL inputA B
BALANCED AUDIO INPUTS
-6dB
PUSH PUSH
IN OUT
AES EBUPUSH
Oppure
or
Oppure
or
Menu Option configurationOption
Menu Option configurationOption Menu Option configurationOption
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type Analog
AES out An In
Input type Analog
AES out An In
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
59 60
InA-B Src Dig InInA-B Src Dig InInA-B Src An InInA-B Src An In
frequenzaHz
dB
Gu
ad
ag
no
60 200 2800
0dB0dB
-6dB
Esempio di un sistema a 3-vie
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
Out 1 Out 2 Out 3
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Esempio di un sistema a 3-vie
61 62
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
26NAC 26NAC
R TE
DO
R
MO LEU O R CE S
E O TR L A
S O
O C ND I P
P hsuernE t
o su cti nF nel rS e tc o
E CSME UN
IGCHTE OL SN EOBd
ocaL l
M
0
484
467
430
44
31
75
12
7
DIMENSIONI DIMENSIONSABMESSUNGEN DIMENSIONS
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquouso
Ma
nu
ale
drsquou
so
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquouso
Ma
nu
ale
drsquou
so
3 4
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
CONNESSIONI PANNELLO RETRO
1586 75 141210 11 13 169 17
14) Connettore ldquo USBrdquoQuesto connettore USB (tipo B) permette di collegare il processore ad un computer per il controllo e lrsquoaggiornamento del firmware tramite un programma dedicato (DVA Network)
15) PRESA DI ALIMENTAZIONE ldquoMAINSrdquoConsente la connessione del cavo di alimentazione fornito in dotazione
16) PORTA FUSIBILE ldquoFUSErdquoAlloggio per fusibile di rete
17) INTERRUTTORE GENERALE ldquoPOWERrdquoLrsquointerruttore permette lrsquoaccensione e lo spegnimento del controllore audio
COMANDI E FUNZIONI
5) SELETTORE ldquo-6dBrdquo
Ingressi bilanciati a livello lineaSono in grado di accettare connettori XLR maschio
Uscite bilanciate a livello linea Sono in grado di accettare connettori XLR femmina
Sezione ldquoAESEBUrdquo
8) CONNETTORE DI INGRESSO ldquoINrdquoIn aggiunta agli ingressi audio analogici egrave stato previsto un ingresso audio digitale SPDIF-AESEBU (AES3) selezionabile tramite il menu di setupLingresso richiede una connessione bilanciata utilizzando un connettore XLR con un cavo a 3 conduttori da 110ohm twistato
9) CONNETTORE DI USCITA ldquoOUTrdquoQuesto connettore permette di rilanciare il segnale audio presente negli ingressi analogici o digitali oppure presenti sulle uscite La sorgente deve essere impostata tramite il menugrave ldquoOptionrdquoLa connessione deve essere conforme allo stesso stardard dellrsquoingresso [rif8]
10) CONNETTORE DI INGRESSO DATA INPUTrdquoConnettore RJ45 ingresso dati
11) CONNETTORE DI USCITA DATA LINKrdquoConnettore RJ45 uscita dati per il collegamento seriale in cascata
12) INDICATORE LUMINOSO ldquoONrdquoQuesto indicatore di colore Verde si accende solo quando lrsquoAC26N ha riconosciuto ed egrave connesso con unitagrave principale RDNET tramite computer
13) INDICATORE LUMINOSO ldquoACTIVErdquoQuesto indicatore di colore Giallo lampeggia quanto egrave attiva una trasmissione dati tra RDNET e il dispositivo
Il selettore permette di ridurre di 6db i livelli di ingresso analogici XLR [6] contemporaneamente per compensare il livelli alti di uscita dei mixer o di altri dispositivi audio Quando la barra del livello segnale degli ingressi sul display [1] risulta sempre al massimo questo indica che il livello del segnale in ingresso egrave elevato e si consiglia di utilizzare lrsquoattenuazione -6dBErsquo possibile controllare quando il selettore egrave attivato dal menu ldquoOptionrdquo
6) CONNETTORI DI INGRESSO ldquoArdquo E ldquoBrdquo
7) CONNETTORI DI USCITA ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo E ldquo6rdquo
Prestare attenzione a collegare le uscite in modo corretto ai diffusori od agli amplificatori in base ai settaggi dei singoli canali per evitare danni e malfuzionamenti
Sezione ldquoRDNETrdquo
PUSH
P SHU
SHPU
P SHU
PUSH
COLLEGAMENTI
Audio analogiciLe connessioni bilanciate permettono di ridurre al minimo il rumore indotto dai cavi stessi e permettere la possibilitagrave di usare cavi di lunghezza importantiQueste connessioni possono essere utilizzate sia sugli ingressi che sulle usciteIl connettore XLR deve essere collegato con il pin 1 a massa pin 2 al caldo (+) e pin 3 al freddo (-) Nel caso di cavo schermato collegare la schermatura al pin 1I cavi ci connessione XLR-XLR e XLR-Jack14(63mm) possono essere utilizzati per il collegamento allrsquoAC26N
12
3
Ingresso
XLR - femmina
Pin 3 =NegativoFreddoFase -VE
1 2
3
Uscita
XLR - Maschio
Pin 2 = PositivoCaldoFase +VE
Pin 1 =SchermoTerraMassa
Pin 1 =SchermoTerraMassa
Pin 2 = PositivoCaldoFase +VE
Pin 3 =NegativoFreddoFase -VE
Anello
Gambo
Punta = PositivoCaldoFase +VE
Anello = NegativoFreddoFase -VE
Gambo=SchemoMassaTerra
Punta
Le connessioni sbilanciate possono essere utilizzate anche se il rumore indotto dai cavi stessi aumenta e i cavi non devono superare la lunghezza di 5mtQueste connessioni possono essere utilizzate sia sugli ingressi che sulle usciteI collegamenti sbilanciati possono abbassare il livello del segnale in ingresso di 6dB per ovviare a questo inconveniente egrave necessario collegare il pin 3 alla massa anche se questo puograve aumentare il rumore
12
3
Ingresso
XLR - femmina
1 2
3
Uscita
XLR - Maschio
Punta Gambo
Punta = Segnale
Gambo=SchemoMassaTerra
Pin 2 = PositivoCaldoFase +VE
Pin 1 =SchermoTerraMassa
Pin 3 = Connesso al Pin 1
Pin 3 = Connesso al Pin 1
Pin 1 =SchermoTerraMassa
Pin 2 = PositivoCaldoFase +VE
Audio digitali (AESEBU)AESEBU (protocollo AES3) egrave un ingresso bilanciato isolato elettricamente tramite un trasformatore Permette di utilizzare due canali audio in un singolo cavo bipolare schermato Le caratteristiche del cavo devono essere impedenza 100ohm twistato e schemato con connettore XLR (AES3 standard)
RD netCiascuna porta RDNet presente sui Control 2 e Control 8 puograve essere collegata a max 32 dispositivi compatibili posti in cascata
Nellrsquoesempio a seguito la porta dellunitagrave di controllo RDNET CONTROL 2 egrave collegata allingresso DATA INPUT di un AC 26N la cui uscita parallela DATA LINK egrave inviata allingresso del successivo AC26N Nellesempio [n] egrave un numero compreso tra 3 e 32 (limite massimo dei dispositivi da collegare ad una sotto rete)
RJ 45
|1|2|3|4|5|6|7|8|
La lunghezza complessiva del cavo CAT5 di una sotto rete NON puograve eccedere i 900 metri
Il connettore deve essere collegato come
1 ndash disponibile per altre funzioni (ad esempio audio +) 2 ndash disponibile per altre funzioni (ad esempio audio ndash)3 ndash disponibile per altre funzioni (ad esempio massa analogica)4 ndash massa digitale5 ndash massa digitale6 ndash disponibile per altre funzioni (ad esempio alimentazione)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
ACCENSIONEAllrsquo accensione del dispositivo si avvia lrsquoinizializzazione che dura alcuni secondi Sul display viene visualizzato il modello il logo e la barra avanzamento caricamento del programma
Al termine del processo di installazione sul display viene visualizzata la finestra del menugrave ldquoMetersrdquo Per conoscere le indicazioni nel dettaglio fare riferimento al paragrafo ldquoDESCRIZIONE FINESTRA MENUrsquo ldquoMetersrdquo
AC26N egrave pronto per lrsquoutilizzo
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquouso
Ma
nu
ale
drsquou
so
5
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquouso
Ma
nu
ale
drsquou
so
6
A B 1 2 3 4 5 6
CONFIGURAZIONE E VISUALIZZAZIONEPer accedere alla finestra del menugrave principale egrave necessario premere il tasto ldquoMENUrdquo ( ) posto sul frontale del dispositivo
ldquoESCrdquo ( ) Da una qualunque pagina del menu premendo il tasto si torna automaticamente alla schermata precedente
MENUrsquo PRINCIPALE
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
I menugrave presenti nel processore sono sei e mostrano eo configurano i parametri del sistemaI menugrave principali sono
Meters visualizzazione livelli degli ingressi e delle uscite visualizzazione programma utilizzato e stato mute rapido
Preset memorizzare salvare ed eliminare le configurazioni del sistema
Matrix selezionare le uscite in funzione del segnale in ingresso
Ch Job configurazione di ogni singolo canale
X-Over configurare le frequenza di taglio e i tipi di filtri per ogni singola uscita
Option assegnazione degli ingressi e delle uscite contrasto display la versione del firmware ingressi ed altre opzioni
I menugrave e le singole opzioni visualizzati possono essere selezionati ruotando la manopolaldquoFUNCTIONS SETECTORrdquo ( ) Per accedere allrsquointerno della selezione egrave necessario evidenziare il parametro desiderato e premere la manopola ldquoPush Enterrdquo ( |) Lo stesso procedimento deve essere adottato per selezionare eo modificare le opzioni alrsquointerno delle voci del menugrave stesso
DESCRIZIONE FINESTRA MENUrsquo ldquoMetersrdquoQuesta finestra permette di visualizzare le configurazioni e lo stato generale degli ingressi e delle uscite la versione del programma utilizzato il suo stato e come viene pilotato il sistema
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
7
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
8
a) CANALI INGRESSO E USCITAI connettori di ingresso ed uscita sono identificati utilizzando le medesime indicazioni presenti sulla serigrafia del retro del dispositivoCon segnali di ingresso digitali lrsquoindicazione ldquoArdquo e ldquoBrdquo corrispondono allrsquoingressoRuotando la manopola ldquoFUNCTIONS SELECTORrdquo [2] si scorrono in modo ciclico i canali ingresso uscita e indicazione di mute generale (d) il canale selezionato viene evidenziato
COMPRESSIONE SEGNALELa compressione del segnale viene visualizzata tramite lo scorrimento della barra di destra dallrsquoalto verso il basso
MUTE Ogni singolo canale puograve essere posto nelle condizione di mute Selezionare il canale e premere la manopola ldquoPush Enterrdquo [2] per confermare il cambiamento di stato Alla indicazione del canale verragrave sostituita la lettera ldquoMrdquo e la barra verragrave completamente evidenziataPer ripristinare il funzionamento normale ripetere le precedenti azioni descritte
c) BARRA LIVELLO SEGNALELrsquoindicazione del livello di ogni singolo canale viene segnalato tramite lo scorrimento delle barra di sinistra
d) MUTE GENERALEErsquo possibile mettere in mute tutti gli ingressi e le uscite contemporaneamente Ruotare la manopola ldquoFUNCTIONS SELECTORrdquo [2] selezionare la lettera ldquoMrdquoe premere la manopola ldquoPush Enterrdquo [2]Per ripristinare il funzionamento normale ripetere le precedenti azioni descritteIl mute generale ha la prioritagrave piugrave alta rispetto ai mute dei singoli canali
b) BARRA LIVELLO COMPRESSIONEMUTE CANALE
e) MODALITArsquo DI COMANDOViene visualizzato come egrave utilizzato eo a quali dispositivi egrave collegato lrsquo AC26N
Local = utilizzo stand-alone Nessuna connessione ad un dispositivo esterno
NET = collegato direttamente alla rete dedicate RDnet e al computer
USB = collegato direttamente ad un computer tramite cavo USB
f) INDICAZIONE STATO IMPOSTAZIONITramite questa indicazione viene visualizzato se il programma caricato egrave stato modificato in uno o piugrave parametri rispetto allrsquoultimo salvataggio
= programma originale
= programma con parametri modificati
g) PROGRAMMA IMPOSTATOIl numero indica il programma caricato ed utilizzato dal sistema riferito alla locazione di salvataggio Fare riferimento al menugrave di ldquoPresetrdquo per ulterioi dettagli
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
DESCRIZIONE FINESTRA MENUrsquo ldquoCh Jobrdquo
Questa finestra permette di visualizzare la configurazione di ogni singolo canale
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) CANALI INGRESSO E USCITAI connettori di ingresso ed uscita sono identificati utilizzando le medesime indicazioni presenti sulla serigrafia del retro del dispositivo
b) LIVELLO DEL SEGNALEIndica guadagno del segnale Laumento nella intensitagrave di un segnale egrave espresso in decibel (dB) Il parametro puograve essere selezionato da -8000dB a +2000dB con passi di 001dB Un aumento di 6dB egrave approssimativamente uguale al raddoppiamento in scala lineare del livello in tensione del segnaleCon un guadagno maggiore di 0dB viene amplificato il segnale mentre con un guadagno inferiore di 0dB viene attenuato il segnale
c) RITARDO DEL SEGNALE (DELAY)I segnale audio riprodotto puograve essere ritardato per permettere lrsquoallineamento acustico Questo compensa le diverse posizioni dei diffusori durante lrsquoinstallazione e la riproduzione sonora ed egrave espresso il mS Il parametro puograve essere selezionato da 00mS a 729mS con passo 01mSPer allineare un segnale audio egrave possibile utilizzare la seguente formula
Ritardo = (GAPx1000)344
Ritardo = ms (espresso in millisecondi)GAP = distanza del diffusore dal punto di riferimento (espresso in metri)
Velocitagrave del suono = 344ms
d) MUTEOgni singolo canale puograve essere posto nella condizione di mute Lo stesso comando puograve essere attivato nella finestra del menugrave laquometersraquo NB Il mute generale ha la prioritagrave piugrave alta rispetto ai mute dei singoli canali
e) FASEPermette la rotazione di fase di 180deg rispetto al segnale in ingressoQuesta rotazione permette lrsquoottimizzazione soprattutto delle basse frequenze nelle installazioni complesse
f) EQUALIZZAZIONEQuesto comando apre la finestra del menugrave dellrsquoequalizzazione del singolo canale Viene principalmente utilizzato per correggere una o piugrave frequenze che devono essere attenuate oppure aumentate
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
109
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
oLrsquo AC26N gestisce 12 filtri per ogni singolo canale di ingresso e uscita con tre diversi tipi configurazioni
Passano tutte le frequenze ma aumenta e diminuisce solo quelle attorno alla frequenza centrale per una determinata banda e un guadagno stabilito
- Equalizzatore high-shelf passa tutte le frequenze ma aumenta o attenua le frequenze sopra la frequenza di taglio selezionata per il guadagno indicato
- Equalizzatore low-shelf passa tutte le frequenze ma aumenta o attenua le frequenze inferiori alla frequenza selezionata per il guadagno indicato
- Equalizzatore PEQ (peaking equalizer) egrave ideale per identificare isolare e correggere solo una determinata gamma di frequenze
f Numerazione dei 12 filtri disponibili per quellrsquoingresso oppure uscita1
f Viene visualizzato il tipo di filtro2
Dis Disinserito (non presente)
PEQ Peaking equalizer
Sh H Filtro high-shelf
Sh L Filtro low-shelf
Esempi PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
NOTA BENEIl parametro Bw determina il campo di frequenze adiacenti alla frequenza impostata dove viene attivato il filtro maggiore egrave il valore Bw maggiore e egrave il campo di frequenze (1Bw=1 ottava)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONEQuesto comando apre la finestra del menugrave compressione del singolo canale
g ) Treshold1
Identifica la soglia dove inizia il rapporto di compressione Il valore di base 11
g ) Ratio2
Indica il rapporto di conversione tra il segnale in ingresso e quello in uscita
g ) Post Gain Attach Release Hold3
Questi dati sono in funzione del rapporto di conversione che si vuole ottenerePost Gain egrave il guadagno di uscitaAttack egrave il tempo di attacco Release egrave il tempo di rilascioHold il tempo di mantenimento
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
DESCRIZIONE FINESTRA MENUrsquo ldquoPresetrdquoQuesta finestra permette di memorizzare fino a 32 configurazioni nellrsquoAC26NLa ditta costruttrice fornisce il sistema con un programma impostato e salvato nella posizione ldquo0rdquo e non sovrascrivibile
032 Indica la locazione di salvataggio della configurazioneQuesto numero appare anche nella finestra ldquoMetersrdquo nella posizione (g) in qualsiasi momento il programma utilizzato puograve essere visualizzato dellrsquoutente
Empty Preset Ersquo il nome che viene associato al numero della locazione quando non egrave salvato nessun settaggio (vuoto)
Local preset Ersquo il nome che viene associato al numero di locazione quando viene salvata una configurazione NB = Ersquo possibile salvare un settaggio con il nome desiderato al max 16 lettere solo utilizzando lrsquointerfaccia tramite il computer
Selezionando un programma appare la seguente finestra
Viene indicato il nome del programma assegnatoPer intervenire sulla applicazione sono a disposizione 3 scelte possibili
Save Il programma viene salvato nella memoria dellrsquoAC 26N
Del Il programma viene cancellato
Load Il programma viene caricato e pronto per essere utilizzato
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
11
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
12
DESCRIZIONE FINESTRA MENUrsquo ldquoX-OverrdquoQuest a finestra permette di selezionare per ogni uscit a un filtro p assa basso un filtro p assa alto oppure tramite la combinazione di entrambe creare un filtro p assa bandaIl filtro presente egrave un Linkwitz-Riley dove egrave possibile selezionare la pendenza di 12dBoct 24dBoct oppure 48dBoct e la relativa frequenza di t aglio
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) CANALI USCITA
I connettori di uscita sono identificati utilizzando le medesime indicazioni presenti sulla serigrafia del retro del dispositivo
b) FILTRO CROSSOVERSelezionare il filtro a seconda delle necessitagrave Ersquo possibile selezionare
Dis Nessun filtro attivato
HP Filtro passa-alto lasciare passare solo la parte di segnale audio superiore alla frequenza di taglio
LP Filtro passa-basso lasciare passare solo la parte di segnale audio inferiore alla frequenza di taglio
Configurazione Filtro Passa basso Passa alto
Nessuna Dis Dis
Passa alto HP Dis
Passa basso Dis LP
Passa banda HP LP
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
c) PENDENZA DI ATTENUAZIONESelezionare la pendenza di attenuazione del segnale audio in base alla diminuzione che si desidera ottenere Piugrave elevata egrave la pendenza di attenuazione a paritagrave di frequenza di taglio maggiore egrave la selezione del segnale Ersquo possibile selezionare
12 corrisponde a 12dboct
24 corrisponde a 24dboct
48 corrisponde a 48dboct
d) FREQUENZA DI TAGLIOPermette drsquoimpostare la frequenza di passaggio delle sole frequenze inferiori (filtro passa-basso) o delle sole frequenze superiori (filtro passa-alto)La scelta del taglio egrave in funzione della riproduzione che si vuole ottenereLrsquounitagrave di misura utilizzata egrave Hz
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
DESCRIZIONE FINESTRA MENUrsquo ldquoMatrixrdquoPermette di selezionare per ogni uscita il segnale in ingresso da utilizzare come sorgente
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) CANALI USCITAIdentificazione del canale in uscita da impostare
b) IDENTIFICAZIONI INGRESSISelezionare il tipo di segnale da abbinare a ogni singola uscita in base alle proprie necessitagrave Ersquo possibile selezionare
In A Viene associato il segnale in ingresso laquoAraquo
In B Viene associato il segnale in ingresso laquoBraquo
In A+B Viene associato la somma algebrica dei due segnali in ingresso laquoAraquo e laquoBraquo
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
DESCRIZIONE FINESTRA MENUrsquo ldquoOptionrdquoPermette di visualizzare le impostazioni sistema come lrsquoassegnazione degli ingressi e delle uscite attenuazione il contrasto del display e la versione del firmware
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711
InA-B SrcQuesta opzione permette di impostare il tipo di segnale audio in ingresso
An In = segnali audio analogici (ingressi ldquoArdquo e ldquoBrdquo)
Dig In = segnali audio digitali (ingresso AESEBU)
DigOut SrcQuesta opzione permette di selezionare la sorgente audio che verragrave indirizzata sul connettore AESEBU OUT (uscita digitale)
An In = segnali audio presenti negli ingressi analogici
Dig In = segnali audio presenti sullrsquoingresso digitale
OUT 1-2 = segnali audio presenti sulle uscite 1 e 2
OUT 3-4 = segnali audio presenti sulle uscite 3 e 4
OUT 5-6 = segnali audio presenti sulle uscite 5 e 6
Input ModePermette di configurare gli ingressi
Indip = sono indipendenti ed autonomi non sono soggetti a vincoli di alcun genere tra di loro
Linked = sono uniti e funzionano in modalitagrave stereoI compressori i filtri i ritardi il volumesono identici per i due canali
13
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
14
Atten Pad
Indica come egrave impostato il selettore ldquo-6dBrdquo posto sul retro [rif 5] Ersquo necessario attivare questo selettore quando i livelli di ingresso analogici sono troppo elevati Il selettore viene attivato solo tramite il pulsante nel menugrave egrave solo una visualizzazione
0dB = selettore non attivatoI segnali di ingresso sono i medesimi della sorgente in ingresso
-6dB = selettore attivatoI segnali in ingresso vengono attenuati di -6dB dal processore interno
Contrast
Consente di regolare il contrasto del display LCD per compensare la differenza di luminositagrave con il luogo di installazione Una maggiore chiarezza del display permette di navigare allrsquointerno dei menugrave in modo corretto e veloceIl settaggio in uscita dalla ditta produttrice egrave 60
10 piugrave chiaro 60 piugrave scuro 100
Fw Vers
Indica la versione del firmware del processore
SPECIFICHE TECNICHE
PRESTAZIONI AUDIORisposta in frequenza +- 01dB (20 to 30kHz)Gamma dinamica 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsione 0002 (1kHz +4dBu)
PRESTAZIONI AUDIO DIGITALI Processore DSP 2856-bit Frequenza elaborazione dati 48KHzConvertitori analogici 24-bit BURR BROWNRitardo di propagazione 15msMemorizzazioni configurazioni 32 preset
CONTROLLI Diplay LCD graficoPulsantiComandi ESC - MENU - FUNCTIONS SELECTION
ENTER
INGRESSIUSCITEIngresso analogico ndeg2 x XLR (3 poli femmina)
Impedenza di ingresso gt10KOhmLivello massimo +21dBu senza PAD
+27dBu con PADUscita analogica ndeg6 x XLR (3 poli maschio)
Impedenza di uscita 50OhmLivello massimo +21dBu Tipo Bilanciato
Ingresso digitale ndeg1x XLR (3 poli femmina)Tipo SPDIF-AESEBU (AES3)
Uscita digitale ndeg1x XLR (3 poli maschio)Tipo conforme allo standard dellrsquoingresso
IngressiUscita RDnet ndeg2 x XLR RJ45 (cavo CAT 5)USB Tipo B
PARAMETRI CONTROLLO AUDIOGuadagno -80dB a +20dB passo 01dBRitardo
ingresso 0 a 729mS passo 01 mSuscita 0 a 340mS passo 01mS
Rotazione di fase 0deg - 180deg
COMPRESSIONESoglia -80dB a +20dB passo 01dBRapporto 11 a Inf1 passo 001Guadagno in uscita 0dB a 40dB passo 01dBTempo di attacco 1mS a 1000mS passo 01mSTempo di rilascio 1mS a 1000mS passo 01mSTempo di mantenimento 1mS a 1000mS passo 01mS
EQUALIZZATORI12 equalizzatori per ogni ingresso e uscitaTipo PEQ (parametrico) Hi-shelf Lo-sheft
Frequenza 20Hz a 20KHz passo 1HzGuadagno -30dB a +15dB passo 001dBBanda 005dB a 2dB passo 001dB (solo per PEQ)
FILTRI CROSSOVERFiltro Linkwitz Riley
Tipo HP Passa-AltoLP Passa-Basso
Pendenza 12dBoct - 24dBoct - 48dBoctFrequenza di taglio 5Hz a 20KHz passo 1Hz
ALIMENTAZIONE Full-range 100-240Vac 50-60HzDIMENSIONI 430482x43x130mm (LxHxD)PESO 19Kg
Note Specifiche soggette a variazioni senza preavviso
CLASSIFICAZIONE EMIIn accordo alle normative EN 55103 lapparato egrave progettato e idoneo allutilizzo in ambienti Elettromagnetici E3 o inferiori (E2 E1)
INTRODUCTIONAC26N is a digital sound processor for the management of audio systems designed for fixed and touring installations AC26N uses the most modern technology with 2856 bit processors and high performance 24 bits ADDA converters The functions available in the processor are input and output levels delay polarity 12 equalization bands for each input and output channel multiple crossover and high performance limiter The control resolution of the filters is 1Hz Inputs and outputs can be set according to many configurations to meet any need AC26N can be controlled in real time and each one of its parameters can be configured on the front panel and through a computer by means of an intuitive graphical interface accessible through the software DVA Network and a dedicated RDnet or USB network connectionThe CPU and DSP software update via PC allows to keep the device up to date It is possible to save and recall 32 preset configurations
Package Contents- AC26N - Operating manual- Software CD- Power cord
Characteristics- 2 Inputs and 6 Outputs with flexible routing- AESEBU addressable stereo inputs and outputs - 2856 bit DSP- BURR-BROWN high performance 24 bit AD converters- Frequency resolution of the filters 1 Hz - 12 parametric equalizers for each input and output- 2 crossover filters for each output with selectable slope 122448 dBoct- High performance DRC multi configuration for limitercompression configuration of
each input and output- Adjustable level in dB polarity and delay for each input and output- Firmware Update via PC- Graphic LCD Display- 32 pre-sets can be stored by the user- USB interface for configuration and control via computer- RDnet interface that allows to control up to 256 remote devices
PC
PC
RDNET hub(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FUNCTIONS FRONT PANEL
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
CONTROLS AND FUNCTIONS
1) DISPLAYThe graphic LCD display allows to view and edit the AC26N information without a computer The display contrast can be set within the main menu
2) ldquoFunctions Selectorrdquo and ldquoPush Enterrdquo KNOBThis control allows to move select and change the parameters within the displayed menusRotation of the knob (Function Selector)- it allows to browse the menu pages- it allows to change the selected parametersPush the knob (Push Enter)- it allows to selectconfirm the parameters
3) ESC button This control allows to exit the displayed menus or to return to the previous view
4) MENU button This control allows to directly access the main menu
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
En
glis
hE
nglis
hu
ser
man
ual
user
man
ual
16
user
man
ual
user
man
ual
Englis
hE
nglis
h
15
DVA USB Manager
The firmware of the amplifier module can be updated via the USB portTo make this update possible and simple a dedicated program has been developed
It is recommended to download DVA USB Manager free software directly from dB Technologies (wwwdbtechnologiescom) in the special section laquoSoftware amp Controllerraquo
DVA Network
The AC26N is equipped with proprietary network interface called RDNET for PC interface through a device (RDNET control)For this purpose a proprietary communication protocol has been developed for receiving and sending data this connection permits real-time monitoring of the diffuser parameters such as output power amplifier temperature limiter status etc It is also possible to select various equalizations or create new ones set the desired volume levels using the specific plug-in
It is recommended to download DVA Network free software directly from dB Technologies (wwwdbtechnologiescom) in the special section laquoSoftware amp Controllerraquo DOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
REAR PANEL CONNECTIONS
1586 75 141210 11 13 169 17
14) USB connectorThis USB connector (type B) allows to connect the processor to a compute to check and update the firmware via a dedicated program (DVA Network)
15) ldquoMAINSrdquo POWER CONNECTIONIt allows to connect the provided power cord
16) FUSE HOLDER ldquoFUSErdquoMain power supply fuse housing
17) ldquoPOWERrdquo MAIN SWITCHThis switch allows to switch on and off the device
PUSH
P SHU
SHPU
P SHU
PUSH
CONNECTIONS
Analog Audio ConnectionsBalanced connections allow to minimize the cable induced noise so cable can be longerSuch connections may be used both on inputs and outputsXLR connector must be cabled with pin 1 to ground pin 2 to hot (+) and pin 3 to cold (-) With shielded cables connect the shield to pin 1XLR-XLR e XLR-Jack 14(63 mm) connection cables can be used to connect the AC26N
12
3
Input
XLR - female
Pin 3 =NegativeCold-VE Phase
Pin 3 =NegativeCold-VE Phase
1 2
3
Output
XLR - Male
Pin 2 = PositiveHot+VE Phase
Pin 2 = PositiveHot+VE Phase
Pin 2 = PositiveHot+VE Phase
Pin 2 = PositiveHot+VE Phase
Pin 1 =ScreenGroundEarth
Pin 1 =ScreenGroundEarth
Pin 1 =ScreenGroundEarth
Pin 1 =ScreenGroundEarth
Ring
Sleeve
Tip = PositiveHot+VE Phase
Ring = NegativeCold-VE Phase
Sleeve=ScreenGroundEarth
Sleeve=ScreenGroundEarth
Tip
The unbalanced connections can also be used However the cable induced noise increases and cable length must not exceed 5 metersSuch connections may be used both on inputs and outputsUnbalanced connection may lower the level of the input signal up to 6dB in order to overcome this drawback connect pin 3 to ground although this can increase the noise
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
18
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
17
CONTROLS AND FUNCTIONS
5) -6dB SELECTORThis selector allows to reduce all the analog XLR [6] input levels by 6 dB at the same time to compensate for the high output levels on the mixers or other audio devices When the input signal level bar on the display [1] remains always at full scale this means that the input signal level is excessive and a -6 dB attenuation is recommendedIn the Option menu it is possible to check when the selector is activated
6) INPUT CONNECTORS ldquoArdquo AND ldquoBrdquoInputs balanced at line levelCapable to accept XLR male connectors
7) OUTPUT CONNECTORS ldquo1rdquo ldquo2rdquordquo 3rdquo ldquo4rdquo ldquo5rdquo AND ldquo6rdquoOutputs balanced at line level Capable to accept XLR famale connectors
Be careful to correctly connect each output to each speaker or amplifier according to the settings of each channels to avoid damages and malfunctions
ldquoAESEBUrdquo Section
8) INPUT CONNECTORIn addition to the analog audio inputs a SPDIF-AESEBU (AES3) digital audio input is also provided It can be selected via the setup menuSuch input requires a balanced connection trough an XLR connector with a 110 ohm twisted 3-wires cable
9) ldquoOUTrdquo OUTPUT CONNECTORThis connector allows to forward audio signals available at the digital or analog inputs or outputs The source must be set by means of the Option menuThe connection must comply with the same standard of the input [8]
RDNET Section
10) DATA INPUT CONNECTORData input RJ45 connector
11) ldquoDATA LINKrdquo OUTPUT CONNECTORRJ45 connector for data output used for serial link in cascade
12) ldquoONrdquo INDICATOR LIGHTThis green indicator turns on only when the AC26N has recognized the RDNET main unit and it is connected to it via computer
13) ldquoACTIVErdquo INDICATOR LIGHTThis yellow indicator flashes when data transmission between RDNET and the device is active
12
3
Input
XLR - female
1 2
3
Output
XLR - Male
Tip Gambo
Tip= Signal
Pin 3 = Link to Pin 1
Pin 3 = Link to Pin 1
Digital Audio Connections (AESEBU)AESEBU (AES3 protocol) is and a balanced input electrically insulated by means of a transformer It allows carrying two audio channels in a single two-wires shielded cable The cable characteristics are twisted 3 poles impedance 100 ohm shielded equipped with XLR connector (AES3 standard)
RDnetEach RDNet port on Control 2 and Control 8 can be connected to maximum 32 cascade-connected compatible devices In the example below the control unit RDNET CONTROL 2 port is connected to the DATA INPUT of an AC 26N whose parallel DATA LINK output is sent to the input of the next AC26N In the example [n] is a number between 3 and 32 (maximum limit for the devices connected to a sub-network)
RJ 45
|1|2|3|4|5|6|7|8|
The overall length of a CAT5 sub-network cable cannot exceed 900 meters
The connector must be connected as follows
1 - Available for other functions (for example audio +) 2 - Available for other functions (for example audio -)3 - Available for other functions (for example analog ground)4 - digital ground5 - digital ground6 - Available for other functions (for example power supply)7 - RS 485 A8 - RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
POWER ON
When the device is turned on the initialization procedure starts It lasts few seconds The display shows the device model the company logo and a program loading progress bar
At the end of the installation process the display shows the Meters menu For further details about the indications refer to the paragraph MENU DESCRIPTION - METERS
AC26N is now ready for use
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION AND DISPLAY
To access the main menu window press the MENU key located on the device front panelIn any page of the menu press the ESC button to return to the previous screen
MAIN MENU
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
There are six menus in the processor They show andor configure the system parametersThe main menus are
Meters Input and output levels display program in progress display quick muting
Preset Store save and delete the system configurations
Matrix Select the outputs according to the input signal
Ch Job Configuration of each individual channel
X-Over Configuration of the cut-off frequency and the types of filters for each output
Option Assignment of the inputs and outputs display contrast firmware version inputs and other options
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
20
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
19
The menus and the individual options displayed can be selected by rotating the knob ldquoFUNCTION SELECTORrdquo ( ) To access the selection highlight the desired parameter and press the ldquoPush Enterrdquo ( | ) knobThe same procedure should be adoptd to select andor change the options inside each menu entry
MENU DESCRIPTION - ldquoMetersrdquo
This window allows to view the configuration and the general conditions of the inputs and outputs the version of the program used the program status and how the system is driven
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) INPUT AND OUTPUT CHANNELSThe input and output connectors are identified by the same information provided on the screen printing located on the device rear sideWith digital input signals the indications A and B concern the inputBy rotating the knob FUNCTION SELECTOR [2] input channels output channels and general muting indications are cyclically scrolled (d) the selected channel is highlighted
b) BAR COMPRESSION LEVEL CHANNEL MUTING
SIGNAL COMPRESSIONSignal compression is displayed by the vertical scrolling (top to down) of the right bar
MUTE Each channel can be individually muted Select the channel and press the Push Enter knob [2] to confirm the change of status The indication of the channel will be replaced by the letter M and the bar will be completely highlightedTo restore normal operation repeat the actions described above
c) SIGNAL LEVEL BARThe level indication for each channel is provided by scrolling the left bar
d) GENERAL MUTINGIt is possible to mute all the inputs and outputs simultaneously Rotate the knob FUNCTION SELECTOR select the letter M and press the Push Enter knobTo restore normal operation repeat the actions described aboveThe general mute has the highest priority with respect to the muting of individual channels
e) CONTROL MODEIt shows how the AC26N is used andor to which devices it is connected
Local = stand-alone usage No connection to an external device
NET = directly connected to dedicated RDnet network and to computer
USB = directly connected to another computer via USB cable
f) SETTING STATUS INDICATIONThis indication shows if the loaded program was amended in one or more parameters with respect to the last saving operation
= original program
= program with modified parameters
g) SET PROGRAMThe number shows the program that is loaded and used by the system with reference to the saving position Refer to the ldquoPresetrdquo menu for further details
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
MENU DESCRIPTION - CH JOB
This window allows to view the configuration of each individual channel
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) INPUT AND OUTPUT CHANNELSThe input and output connectors are identified by the same information provided on the screen printing located on the device rear side
b) SIGNAL LEVELIt shows the signal gain The increased signal intensity is expressed in decibels (dB) Such parameter can be selected in the range from -8000 dB to +2000 dB in steps of 001 dB An increase of 6 dB is approximately equal to doubling - in a linear scale - the signal voltage levelIf the gain exceeds 0 dB the signal is amplified while if the gain is lower than 0 dB the signal is attenuated
c) SIGNAL DELAYThe reproduced audio signal may be delayed to perform an acoustic alignment This compensates for the different positions of the speakers during the installation and the sound reproduction it is expressed in ms The parameter can be selected in the range from 00 ms to 729 ms in steps of 01 msThe following formula can be used to align an audio signal
Delay = (GAPx1000)344
Delay = ms (in milliseconds)GAP = distance between speaker and reference point (in meters)Speed of sound = 344 ms
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
22
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
21
d) MUTEEach channel can be individually muted The same command can be activated in the Meters Menu
NOTE The general mute has the highest priority with respect to the muting of individual channels
e) PhaseIt performs a phase rotation of 180deg with respect to the input signalSuch phase rotation allows the optimization in special way for low frequencies in complex installations
M M
f) EQUALIZATIONThis control opens the menu controlling the single channel equalization It is mainly used to correct one or more frequencies that must be reduced or increased
The AC26N manages 12 filters for each individual channel input and output with three different kinds of configuration
- PEQ Equaliser (peaking equalizer) ideal to identify isolate and correct only a certain range of frequencies All frequencies pass only those around the centre frequency are increased and decreased for a given bandwidth and set gain
- High-shelf Equalizer All frequencies pass but frequencies above the selected cut-off frequency are increased or attenuated by the given gain
- Low-shelf Equalizer All frequencies pass but frequencies below the selected cut-off frequency are increased or attenuated by the given gain
f Numbering of the 12 available filters for the specific input or output1
f Displays the kind of filter2
Dis Switched off (not present)
PEQ Peaking equlizer
Sh H High-shelf Filter
Sh L Low-shelf Filter
Examples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
NOTE
The parameter Bw defines the range of frequencies close to the set frequency where the filter is activated the greater the value of Bw the wider is the frequencies range (1 Bw = 1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONThis control opens the menu controlling the compression for the single channel
g1) ThresholdIdentifies the starting threshold for the compression ratio Base value 11
g2) RatioIndicates the conversion ratio between input and output signal
g3) Post Gain Attach Release HoldThese data are in function of the conversion ratio to achieve Post Gain is the output gain Attack is the attack time Release is the release time Hold is the holding time
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
24
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
23
MENU DESCRIPTION - PRESET
This window allows to store up to 32 configurations in the AC26NThe manufacturer provides the system with a program set and saved in position 0 that is not possible to overwrite
032 Indicates the location where the configuration is savedThis number also appears in the window Meters in position (g) The program in use can be displayed at any time by the user
Empty Preset It is the name associated with the location number when no setting is saved (empty)
Local preset It is the name associated with the location number when a setting is saved NOTE = It is possible to save a setting with the desired name up to 16 letters only via the computer interface
When a program is selected the following window is displayed
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
The name of the assigned program is displayed3 possible choices are available when working on the application
Save The program is saved in the AC 26N memory
Del The program is deleted
Load The program is loaded and ready to be used
MENU DESCRIPTION - X-OVER
This window allows to select for each output a low pass filter a high pass filter or create a band-pass filter via the combination of bothThe available filter is a Linkwitz-Riley where it is possible to select slopes of 12 dBoct 24 dBoct or 48 dBoct and their cut-off frequency
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) OUTPUT CHANNELS
The output connectors are identified by the same information provided on the screen printing located on the device rear side
b) CROSSOVER FILTERSelect the filter according to needs It is possible to select
Dis No filter enabled
HP High-pass filter set it to allow only the part of audio signal above the cut-off frequency
LP Low-pass filter set to allow only the part of audio signal below the cut-off frequency
Filter configuration Low-pass High-pass
Nothing Dis Dis
High-pass HP Dis
Low-pass Dis LP
Band-pass HP LP
12dBoct
24dBoct
Hz
dB
48dBoct
12dBoct
24dBoct
frequency
frequency
frequency
frequency
Hz
dB
48dBoct
c) ATTENUATION SLOPESelect the attenuation slope of the audio signal on the basis of the desired attenuation The higher the attenuation slope at the same cut-off frequency the greater the signal selection It is possible to select
12 equal to 12 dBoct
24 equal to 24 dBoct
48 equal to 48 dBoct
d) CUT-OFF FREQUENCYTo set the passing frequency for the lower frequencies only (low-pass filter) or the higher frequencies only (high-pass filter)The choice of the cut-off depends on the desired sound reproductionThe unit of measurement used is Hz
Hz
Hz
dB
dB
Ga
inG
ain
Ga
inG
ain
f0
f0
0dB0dB
0dB
-6dB
-6dB
0dB
0dB
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
26
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
25
MENU DESCRIPTION - MATRIX
For each output it allows to select the input signal to use as the source
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) OUTPUT CHANNELSIdentification of the output channel to set
b) IDENTIFICATIONS OF THE INPUTSIt selects the type of signal to match each output as needed It is possible to select
In A Associated with the input signal ldquoArdquo
In B Associated with the input signal ldquoBrdquo
In A+B Associated with the algebraic sum of the two input signals ldquoArdquo and ldquoBrdquo
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
MENU DESCRIPTION - OPTION
Allows to display the system settings such as the allocation of the inputs and outputs attenuation display contrast and firmware version
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcThis option allows to set the type of input audio signal
An In = Analog audio signals (inputs A and B)
DigIn = Digital audio signals (AESEBU input)
DigOut SrcThis option allows to select the audio source that will be forwarded to the connector AESEBU OUT (digital output)
An In = Audio signals available at analog inputs
Dig In = Audio signals available at digital inputs
OUT 1-2 = Audio signals available on outputs 1 and 2
OUT 3-4 = Audio signals available on outputs 3 and 4
OUT 5-6 = Audio signals available on outputs 5 and 6
Input ModeIt allows to configure the inputs
Indip = They are independent not subject to constraints of any kind between them
Linked = They are connected and work in stereo mode Compressors filters delays volume are identical for the two channels
Atten PadIt shows how to set the -6 dB switch located on the rear side [Ref 5] It is necessary to activate this selector when the analog input levels are too high The selector can be activated only by means of the button the menu is for display only
0 dB = Selector not activated The input signals are the same as the input source
-6 dB = Selector activated The input signals are attenuated by -6 dB with reference to the inner
processor
ContrastAllows to adjust the LCD display contrast to compensate for the brightness difference at the installation sites Greater display brightness allows to navigate correctly and quickly within the menuThe manufacturer output setting is 60
10 More bright 60 More dark 100
Fw VersIt shows the processor firmware version
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
28
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
27
TECHINICAL SPECIFICATION
AUDIO PERFORMANCEFrequency Response +- 01dB (20 to 30kHz)Dynamic Range 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistortion 0002 (1kHz +4dBu)
DIGITAL AUDIO PERFORMANCE Processor DSP 2856-bit Data processing Frequency 24-bit BURR BROWNAnalog converters 24-bit BURR BROWNPropagation Delay 15msStoring configurations 32 preset
CONTROLS Display LCD graficoButtonsControls ESC - MENU - FUNCTIONS SELECTION
ENTERINPUTSOUTPUTSAnalog Input ndeg2 x XLR (3 pole female)
Input impedance gt10KOhmMaximum Level +21dBu senza PAD
+27dBu con PADAnalog Output ndeg6 x XLR (3 pole male)
Output impedance 50OhmMaximum Level +21dBu Type Balanced
Digital Input ndeg1x XLR (3 pole female)Type SPDIF-AESEBU (AES3)
Digital Output ndeg1x XLR (3 pole male)Type Compliant with the input standard
RDnet InputsOutput ndeg2 x XLR RJ45 (CAT 5 cable)USB Tipo B
SOUND CONTROL PARAMETERSGain -80dB a +20dB step 01dBDelay
Input 0 a 729mS step 01 mSOutput 0 a 340mS step 01mSPhase Rotation 0deg - 180deg
COMPRESSIONThreshold -80dB a +20dB step 01dBRatio 11 a Inf1 step 001Output gain 0dB a 40dB step 01dBAttack time 1mS a 1000mS step 01mSRelease time 1mS a 1000mS step 01mSHold time 1mS a 1000mS step 01mS
EQUALIZERS12 equalizers for each input and outputType PEQ (parametrico) Hi-shelf Lo-sheft
Frequency 20Hz a 20KHz step 1HzGain -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (only with PEQ)
CROSSOVER FILTERSFilter Linkwitz Riley
Type HP High-pass LP Low-pass
Slope 12dBoct - 24dBoct - 48dBoctCUT-OFF FREQUENCY 5Hz a 20KHz passo 1Hz
POWER SUPPLY Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)
1719x17x51 inch (WxHxD)WEIGHT 19Kg
(42 lbs)Note Specifications subject to change without notice
EMI CLASSIFICATIONAccording to the standards EN 55103 this equipment is designed and suitable to operate in E3 (or lower E2 E1) Electromagnetic environments
EINLEITUNG
Verpackungsinhalt
Eigenschaften
AC26N ist ein digitaler Audio-Prozessor fuumlr die Verwaltung von Audio-Systemen der fuumlr feste und mobile Installationen entwickelt wurde AC26N benutzt die modernste Technologie mit 2856 bit-Prozessoren und 24-bit-ADDA-Wandlern mit hoher Leistungsfaumlhigkeit Die verfuumlgbaren Funktionen des Prozessors sind Ein- und Ausgangsstufen Verzoumlgerung (delay) Polaritaumlt 12 Equalizer-Frequenzen fuumlr Ein- und Ausgangskanal viele Crossover-Wahlmoumlglichkeiten und Limiter mit hoher Leistung Die Filter-Kontrolle hat eine Aufloumlsung von 1 Hz Die Ein- und Ausgaumlnge koumlnnen mit unterschiedlichen Einstellungen geregelt werden um allen Anforderungen gerecht zu werden AC26N kann in Echtzeit kontrolliert werden und jeder Parameter kann am Frontpaneel und vom Computer mit intuitiver graphischer Schnittstelle mittels Software DVA Network zugaumlnglich und einer Netzverbindung RDnet oder uumlber USB eingestellt werdenDie SW-Aktualisierung fuumlr CPU und DSP uumlber PC erlaubt die Vorrichtung auf dem aktuellen Stand zu halten Man kann 32 vorgesehene Konfigurationen speichern und aufrufen
- AC26N - Bedienungsanleitung- Software-CD- Versorgungskabel
- 2 Ein- und 6 Ausgaumlnge mit flexibler Adressierung- Adressierbarer Stereo-Ein- und Ausgang AESEBU - DSP 2856-bit- AD-Wandler BURR BROWN 24-bit mit hoher Leistungsfaumlhigkeit- Aufloumlsungsfrequenz der Filter 1 Hz - 12 parametrische Equalizer fuumlr jeden Ein- und Ausgang- 2 Crossover-Filter fuumlr jeden Ausgang mit auswaumlhlbarer Neigung 122448dBoct- DRC Multikonfiguration mit hoher Leistungsfaumlhigkeit fuumlr die Konfiguration des
Limitersder Kompression jedes Ein- und Ausgangs- Einstellbare dB-Stufe Polaritaumlt und Verzoumlgerung (delay) fuumlr jeden Ein- und Ausgang- Firmware-Aktualisierung uumlber PC- Graphisches LCD-Display- 32 Voreinstellungen vom Benutzer einstellbar- USB-Schnittstelle fuumlr die Kontrolle und Konfiguration mit dem Computer- Schnittstelle RDnet welche erlaubt bis zu 256 fern liegende Vorrichtungen
zu kontrollieren
PC
PC
RDNET control(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FUNKTIONEN VORDERSEITE
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
BEDIENUNGEN UND FUNKTIONEN
1) DISPLAYDas graphische LCD-Display erlaubt die Informationen des AC26N ohne einen Computer zu benutzen anzuzeigen und zu editieren Der Kontrast kann im Hauptmenuuml eingestellt werden
2) DREHGRIFF Functions Selector UND Push EnterDiese Kontrolle erlaubt sich in den Menuumls auf dem Display zu bewegen und die Parameter auszuwaumlhlen und zu veraumlndernDrehung des Drehgriffes (Functions Selectors)- Man kann sich innerhalb der verschiedenen Menuumlseiten bewegen- Erlaubt die Veraumlnderung der ausgewaumlhlten ParameterDruck des Drehgriffes (Push Enter)- Erlaubt die AuswahlBestaumltigung der Parameter
3) Taste ldquoESCrdquo Diese Kontrolle erlaubt die angezeigten Menuumls zu verlassen oder zur vorherigen Anzeige zuruumlckzukehren
4) Taste ldquoMenuumlrdquo Diese Kontrolle erlaubt den direkten Zugang zum Hauptmenuuml
Deuts
chD
euts
chB
ed
ien
un
gsan
leit
un
gB
ed
ien
un
gsan
leit
un
g
29
Deuts
chD
euts
chB
ed
ien
un
gsan
leit
un
gB
ed
ien
un
gsan
leit
un
g
30
DVA USB Manager
Die Firmware des Verstaumlrkermoduls kann uumlber den USB-Anschluss aktualisiert werdenUm diesen Vorgang zu ermoumlglichen und zu vereinfachen wurde ein dediziertes Programm entwickelt das beim Hersteller angefordert und auf einen Computer installiert werden muss
Wir empfehlen die Software DVA USB Manager direkt von der Webseite dB Technologies (wwwdbtechnologiescom) im Abschnitt laquoSoftware amp Controllerraquo herunterzuladen
DVA Network
AC26N ist mit einer eigenen als RDNET bezeichneten Netzschnittstelle ausgestattet dank der es uumlber ein Interface (RDNET Control) an einen Computer angeschlossen werden koumlnnenHierzu wurde ein Kommunikationsprotokoll entwickelt mit dem die Daten empfangen und gesendet werden Dank dieser Verbindung koumlnnen die Lautsprecherparameter wie Ausgangsleistung Verstaumlrkertemperatur Limiterstatus usw in Echtzeit kontrolliert werden Auszligerdem koumlnnen verschiedene Entzerrungen ausgewaumlhlt bzw neue erstellt werden oder die gewuumlnschte Lautstaumlrke eingestellt werden
Wir empfehlen die Software DVA_Network direkt von der Webseite dB Technologies (wwwdbtechnologiescom) im Abschnitt laquoSoftware amp Controllerraquo herunterzuladenDOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
RUumlCKWANDANSCHLUumlSSE
1586 75 141210 11 13 169 17
14) USB-SteckverbinderDieser USB-Steckverbinder (Typ B) erlaubt den Prozessor an einem Computer anzuschlieszligen um die Firmware mit dem speziellen Programm (DVA Network) zu kontrollieren und zu aktualisieren
15) STROMANSCHLUSS MAINSErlaubt den Anschluss des mitgelieferten Versorgungskabels
16) SICHERUNGSTRAumlGER FUSEAufnahme fuumlr die Netz-Sicherung
17) HAUPTSCHALTER POWERDer Schalter erlaubt das Aus- und Einschalten des Audio-Controllers
BEDIENUNGEN UND FUNKTIONEN
5) WAHLSCHALTER -6dBDer Wahlschalter erlaubt das Level des analogen Eingangs XLR [6] um 6 dB zu verringern und gleichzeitig das hohe Ausgangslevel der Mixer oder anderer Audio-Vorrichtungen auszugleichen Wenn der Balken des Signallevels der Eingaumlnge auf dem Display [1] immer auf Maximum steht zeigt dies an dass das Signallevel am Eingang hoch ist und es wird empfohlen die Daumlmpfung -6dB zu benutzenIm Menuuml Option ist es moumlglich zu kontrollieren ob der Wahlschalter aktiviert ist
6) STECKVERBINDER AM EINGANG A UND BAuf Leitungslinie ausgeglichene EingaumlngeSie koumlnnen auch XLR-Steckdosen aufnehmen
7) AUSGANG-STECKVERBINDER ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo UND ldquo6rdquoAuf Leitungslinie ausgeglichene Ausgaumlnge Sie koumlnnen auch XLR-Stecker aufnehmen
Darauf achten dass die Ausgaumlnge korrekt entsprechend der Einstellungen der einzelnen Kanaumlle an den Lautsprechern oder Verstaumlrkern angeschlossen sind um Schaumlden und Fehlfunktionen vorzubeugen
Abschnitt ldquoAESEBUrdquo
8) EINGANGS-STECKVERBINDER INZusaumltzlich zu den analogen Audio-Eingaumlngen wurde ein digitaler Audio-Eingang SPDIF-AESEBU (AES3) vorgesehen der uumlber das Setup-Menuuml ausgewaumlhlt werden kannDer Eingang erfordert einen ausgeglichenen Anschluss mit einem XLR-Steckverbinder mit einem verdrillten Kabel mit 3 Leitern von 110 Ohm
9) AUSGANGS-STECKVERBINDER OUTDieser Steckverbinder erlaubt das Audiosignal an den analogen oder digitalen Eingaumlngen oder Ausgaumlngen zu verteilen Die Quelle muss uumlber das Menuuml Option eingestellt werdenDer Anschluss muss demselben Standard des Eingang entsprechen [Ref 8]
Abschnitt ldquoRDNETrdquo
10) EINGANGS-STECKVERBINDER DATA INPUTSteckverbinder RJ45 fuumlr den Dateneingang
11) AUSGANGS-STECKVERBINDER DATA LINKSteckverbinder RJ45 fuumlr den Datenausgang Fuumlr die serielle Kaskaden-Verbindung
12) LEUCHTANZEIGE ONDiese gruumlne Anzeige leuchtet nur wenn AC26N uumlber den Computer mit der Haupteinheit RDNET verbunden ist und diese erkannt hat
13) LEUCHTANZEIGE ACTIVEDiese gelbe Anzeige blinkt wenn eine Datenuumlbertragung zwischen RDNET und der Vorrichtung aktiv ist
PUSH
P SHU
SHPU
P SHU
PUSH
ANSCHLUumlSSE
Analoge Audio-AnschluumlsseDie ausgeglichenen Anschluumlsse erlauben die Geraumlusche der Kabel auf ein Minimum zu verringern und so die Benutzung langer Kabel zuzulassenDiese Anschluumlsse koumlnnen sowohl an den Ein- als auch an den Ausgaumlngen benutzt werdenDer XLR-Steckverbinder muss mit Pin 1 an Masse Pin 2 am Pluspol (+) und Pin 3 am Minuspol (-) angeschlossen werden Bei einem abgeschirmten Kabel muss die Abschirmung an Pin 1 liegenDie Verbindungskabel XLR-XLR und XLR-Jack 14 (63 mm) koumlnnen fuumlr den Anschluss
12
3
Eingang
XLR weiblichen
Pin 3 = MinuspolErkaumlltungphase -VE
Pin 3 = MinuspolErkaumlltungphase -VE
1 2
3
Ausgang
XLR maumlnnlichen
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Ring
Schaft
Spitze = PluspolWaumlrmephase +VE
Ring = MinuspolErkaumlltungphase -VE
Schaft=SchirmMasse
Spitze
Die nicht ausgeglichenen Anschluumlsse koumlnnen auch benutzt werden wenn die Kabelgeraumlusche ansteigen und diese Kabel duumlrfen nicht laumlnger sein als 5 MeterDiese Anschluumlsse koumlnnen sowohl an den Ein- als auch an den Ausgaumlngen benutzt werdenDie nicht ausgeglichenen Anschluumlsse koumlnnen das Signallevel am Eingang um 6 dB verringern um dem vorzubeugen muss Pin 3 an Masse angeschlossen werden obwohl dies das Geraumlusch verstaumlrken kann
12
3
Eingang
XLR weiblichen
1 2
3
Ausgang
XLR maumlnnlichen
Spitze Schaft
Spitze = Signal
Schaft=SchirmMasse
Pin 3 = zu Pin 1 gebruumlckt
Pin 3 = zu Pin 1 gebruumlckt
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
31
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
32
Digitales Audio (AESEBU)AESEBU (Protokoll AES3) ist ein ausgeglichener und uumlber einen Transformator elektrisch isolierter Eingang Er erlaubt die Benutzung von zwei Kanaumllen an einem einzigen abgeschirmten bipolaren Kabel Das gedrillte Kabel muss 3-polig sein eine Impedanz von 100 Ohm haben und mit einem XLR-Steckverbinder (AES3 Standard) abgeschirmt sein
RdnetJeder Port RDNet an Control 2 und Control 8 kann an max 32 kompatiblen Vorrichtungen die in Kaskade geschaltet sind angeschlossen werden Im nachstehenden Beispiel ist der Port der Kontrolleinheit RDNET CONTROL 2 am Eingang DATA INPUT eines AC 26N angeschlossen dessen paralleler Ausgang DATA LINK zum Eingang des naumlchsten AC26N geht Im Beispiel ist [n] eine Nummer zwischen 3 und 32 (maximale Anzahl der anschlieszligbaren Vorrichtungen an nur einem Netz)
RJ 45
|1|2|3|4|5|6|7|8|
Die Gesamtlaumlnge des Kabels CAT5 eines Unternetzes kann NICHT laumlnger als 900 Meter sein
Der Steckverbinder muss wie folgt angeschlossen sein1 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio +) 2 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio -)3 ndash Verfuumlgbar fuumlr andere Funktionen (zB analoge Masse)4 ndash digitale Masse5 ndash digitale Masse6 ndash Verfuumlgbar fuumlr andere Funktionen (zB Versorgung)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
EINSCHALTEN
Beim Einschalten der Vorrichtung startet die Initialisierung die einige Sekunden lang dauert Auf dem Display wird das Modell das Logo und der Fortschrittsbalken der Ladung des Programms angezeigt
Nach der Initialisierung erscheint auf dem Display das Menuumlfenster Meters Um die Angaben im Detail zu erfahren beziehen Sie sich bitte auf das Kapitel BESCHREIBUNG DES MENUumlFENSTERS Meters
AC26N kann jetzt benutzt werden
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
MENUrsquo PRINCIPALE
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Die sechs Menuumls im Prozessor zeigen undoder konfigurieren die Systemparameter
Anzeige der Levels der Ein- und Ausgaumlnge Anzeige des benutzten Programms und dessen Status Mute schnell
Speicherung Speicherung und Eliminierung der Systemkonfigurationen
Auswahl der Ausgaumlnge je nach Eingangssignal
Konfiguration jedes einzelnen Kanals
Konfiguration der Schnittfrequenzen und der Filtertypen fuumlr jeden einzelnen Ausgang
Zuordnung der Ein- und Ausgaumlnge Kontrast des Displays Firmware-Version Eingaumlnge und andere Optionen
Das Menuuml und die einzelnen Optionen der Anzeige koumlnnen durch Drehen des Drehgriffes FUNKTIONS SELECTOR ( ) ausgewaumlhlt werden
Die Hauptmenuumls sind
Meters
Preset
Matrix
Ch Job
X-Over
Option
Um die Auswahl zu treffen muss der gewuumlnschte Parameter auswaumlhlt und der Drehgriff Push Enter( | ) gedruumlckt werdenDas selbe Verfahren muss fuumlr die Auswahl undoder die Aumlnderung der Optionen innerhalb der Menuumlpunkte angewendet werden
BESCHREIBUNG DES MENUumlFENSTERS Meters
Diese Seite erlaubt die Konfigurationen und den allgemeinen Status der Ein- und Ausgaumlnge der benutzten Programmversion dessen Status und die Steuerung des Systems anzuzeigen
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
KONFIGURATION UND ANZEIGE
Um in das Fenster des Hauptmenuumls zu gelangen muss die Taste Menuuml ( ) auf der Frontseite der Vorrichtung gedruumlckt werdenMit der Taste ESC ( ) kehrt man von jeder Seite des Menuumls auf die vorherige Seite zuruumlck
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
33
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
34
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziertBei den digitalen Eingangssignalen entspricht die Angabe A und B dem EingangDreht man den Drehgriff FUNCTIONS SELECTOR [2] durchlaumluft man zyklisch die Ein- und Ausgangskanaumlle und die Angabe Mute allgemein (d) der ausgewaumlhlte Kanal wird hervorgehoben
b) BALKEN FUumlR DAS KOMPRESIONSLEVELMUTE KANAL
SIGNALKOMPRESSIONDie Signalkompression wird durch das Gleiten des rechten Balkens von oben nach unten angezeigt
MUTE Jeder einzelne Kanal kann auf Mute gestellt werden Den Kanal auswaumlhlen und den Drehgriff Push Enter [2] druumlcken um die Aumlnderung des Status zu bestaumltigen Die Angabe des Kanals wird durch den Buchstaben M ersetzt und der Balken wird komplett hervorgehobenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werden
c) BALKEN DES SIGNALLEVELSDie Anzeige des Levels jedes einzelnen Kanals wird durch das Gleiten des linken Balkens angezeigt
d) MUTE ALLGEMEINEs ist moumlglich alle Ein- und Ausgaumlnge gleichzeitig auf Mute zu schalten Den Drehgriff FUNCTIONS SELECTOR drehen den Buchstaben M waumlhlen und dann den Drehgriff Push Enter druumlckenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werdenDie allgemeine Stummschaltung hat eine houmlhere Prioritaumlt als die Stummschaltung der einzelnen Kanaumlle
e) ANSTEUERUNGSARTENEs wird angezeigt wie AC26N benutzt wird undoder an welchen Vorrichtungen es angeschlossen ist
= Benutzung stand-alone Kein Anschluss an einer externen Vorrichtung
= Direkt am Netz RDnet und am Computer angeschlossen
= Uumlber USB-Kabel direkt am Computer angeschlossen
f) ANZEIGE DES STATUS DER EINSTELLUNGENHier wird angezeigt ob einer oder mehrere Parameter des geladenen Programms im Vergleich zur letzten Speicherung veraumlndert wurden
Original-Programm
Programm mit veraumlnderten Parametern
g) EINGESTELLTES PROGRAMMDie Nummer zeigt das vom System geladene und benutzte Programm in Bezug auf die Lokalisierung der Speicherung an Fuumlr weitere Details beziehen Sie sich bitte auf das Menuuml Preset
Local
NET
USB
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
BESCHREIBUNG DES MENUumlFENSTERS Ch Job
Dieses Fenster erlaubt die Anzeige der Konfiguration jedes einzelnen Kanals
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) SIGNALLEVELZeigt die Signalstaumlrke an Das Ansteigen der Signalintensitaumlt wird in Dezibel (dB) ausgedruumlckt Der Parameter kann zwischen -8000 dB und +2000 dB in Schritten von 001 dB ausgewaumlhlt werden Ein Anstieg von 6 dB ist fast gleich eine Verdoppelung in linearer Skala des Spannungswertes des SignalsBei einer Staumlrke von 0 dB wird das Signal verstaumlrkt waumlhrend es ein einer Staumlrke von weniger als 0 dB abgeschwaumlcht wird
c) VERZOumlGERUNG DES SIGNALS (DELAY)Das wiedergegebene Audio-Signal kann verzoumlgert werden um die akustische Ausrichtung zu erlauben Dies gleicht die verschiedenen Positionen der Lautsprecher bei der Installation und Klangwiedergabe aus und wird in mS ausgedruumlckt Der Parameter kann zwischen 00 mS und 729 mS in Schritten von 01mS ausgewaumlhlt werden
Um ein Audiosignal auszurichten kann folgende Formel benutzt werden
Verzoumlgerung = GAPx1000)344
Verzoumlgerung = mS (in Millisekunden ausgedruumlckt)GAP = Abstand des Lautsprechers vom Referenzpunkt (in Metern ausgedruumlckt)Klanggeschwindigkeit = 344 ms
d) MUTEJeder einzelne Kanal kann auf Mute gestellt werden Derselbe Befehl kann im Fenster des Menuumls Meters aktiviert werden PS Die al lgemeine Stummschaltung hat eine houmlhere Priori taumlt als die Stummschaltung der einzelnen Kanaumlle
e) PHASEErlaubt die Phasenrotation um 180deg zum EingangssignalDiese Rotation erlaubt vor Allem die Optimierung der niederen Frequenzen bei komplexen Installationen
f) ENTZERRUNGENDieser Befehl oumlffnet das Menuumlfenster fuumlr die Entzerrung des einzelnen Kanals Er wird vor Allem benutzt um eine oder mehrere Frequenzen zu korrigieren die gedaumlmpft oder verstaumlrkt werden muumlssen
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
35
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
36
AC26N verwaltet 12 Filter fuumlr jeden einzelnen Ein- und Ausgangskanal mit drei verschiedenen Konfigurationen- Equalizer PEQ (peaking equalizer) ist ideal um nur ein bestimmtes Frequenzband
zu identifizieren zu isolieren und zu korrigieren Es gehen alle Frequenzen durch aber nur die um die mittlere Frequenz steigt und sinkt um eine bestimmte Bandbreite und eine bestimmte Staumlrke
- Equalizer High-Shelf geht alle Frequenzen durch aber die Frequenzen uumlber der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
- Equalizer Low-Shelf geht alle Frequenzen durch aber die Frequenzen unter der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
f Nummerierung der 12 verfuumlgbaren Filter fuumlr diesen Ein- oder Ausgang1
f2 Es wird der Filtertyp angezeigt
Dis Ausgeschaltet (nicht vorhanden)
PEQ Peaking equalizer
Sh H Filter High-Shelf
Sh L Filter Low-shelf
Beispiele PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
ANMERKUNGDer Parameter Bw legt das Frequenzfeld neben der eingestellten Frequenz fest wo der Filter aktiviert wird je houmlher der Bw-Wert desto houmlher das Frequenzfeld (1Bw=1 Oktave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filter High-Shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filter Low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) KOMPRESSIONDieser Befehl oumlffnet das Menuumlfenster fuumlr die Kompression des einzelnen Kanals
g1) TresholdIdentifiziert die Schwelle an der das Kompressionsverhaumlltnis beginnt Der Basiswert 11
g2) RatioIdentifiziert das Kompressionsverhaumlltnis zwischen dem Ein- und Ausgangssignal
g3) Post Gain Attach Release HoldDiese Daten entsprechen dem Kompressionsverhaumlltnis das man erreichen moumlchte
Post Gain ist der Gewinn am AusgangAttack ist die Anschlusszeit Release ist die ReleasezeitHold ist die Beibehaltungszeit
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
BESCHREIBUNG DES MENUumlFENSTERS Preset
Dieses Fenster erlaubt bis zu 32 Konfigurationen im AC26N zu speichernDer Hersteller liefert das System mit einem voreingestellten Programm das auf Position 0 gespeichert ist und nicht uumlberschrieben werden kann
032 Es zeigt die Lokalisierung der Speicherung der KonfigurationDiese Nummer erscheint auch im Fenster Meters auf der Position (g) Das benutzte Programm kann jederzeit vom Benutzer angezeigt werden
Empty Preset Es ist der Name der der Nummer der Lokalisierung zugeordnet wird wenn keine Einstellung gespeichert ist (leer)
Local preset Es i s t de r Name de r de r Nummer de r Loka l i s i e rung zugeordnet wird wenn eine Konfiguration gespeichert wird
ANMERKUNG = Man kann eine Einstellung mit dem gewuumlnschten Namen mit max 16 Buchstaben nur speichern wenn man die Schnittstelle uumlber den Computer benutzt
Bei der Wahl eines Programms erscheint folgendes Fenster
Anzeige des Namens der dem Programm zugeordnet istUm auf die Anwendung einzuwirken stehen 3 Auswahlmoumlglichkeiten zur Verfuumlgung
Das Programm wird im Speicher des AC 26N gespeichert
Das Programm wird geloumlscht
Das Programm wird geladen und ist bereit fuumlr die Benutzung
Save
Del
Load
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
37
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
38
BESCHREIBUNG DES MENUumlFENSTERS X-Over
Dieses Fenster erlaubt fuumlr jeden Ausgang einen Bassdurchgangsfilter einen Hochdurchgangsfilter oder mittels Kombination von beiden einen Banduumlbergangsfilter zu waumlhlenDer Filter ist ein Linkwitz-Riley wo man die Neigung von 12 dBoct 24dBoct oder 48 dBoct und die entsprechende Schnittfrequenz auswaumlhlen kann
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) AUSGANGSKANAumlLE
Die Steckverbinder am Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) FILTER CROSSOVERDen Filter nach Bedarf waumlhlen Man kann folgendes auswaumlhlen
Dis Kein Filter aktiviert
HP Hochdurchgangsfilter nur den Teil des Audiosignals durchlassen der uumlber der Schnittfrequenz liegt
LP Bassdurchgangsfilter nur den Teil des Audiosignals durchlassen der unter der Schnittfrequenz liegt
Filter-Konfiguration Tiefpass Hochpass
Nichts Dis Dis
Hochpass HP Dis
Tiefpass Dis LP
Bandpass HP LP
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
c) DAumlMPFUNGSNEIGUNGDie Daumlmpfungsneigung des Audiosignals auf der Basis der Verringerung auswaumlhlen die man erreichen moumlchte Je houmlher die Daumlmpfungsneigung bei gleicher Schnittfrequenz desto groumlszliger ist die Signalauswahl Man kann folgendes waumlhlen
12 entsprechend 12 dboct
24 entsprechend 24 dboct
48 entsprechend 48 dboct
d) SCHNITTFREQUENZErlaubt die Durchgangsfrequenz der niederen Frequenzen (Bassdurchgangsfilter) oder der hohen Frequenzen (Hochdruchgangsfilter) einzustellenDie Auswahl des Schnitts bezieht sich auf die Wiedergabe die man erreichen moumlchteDie benutzte Maszligeinheit ist Hz
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
BESCHREIBUNG DES MENUumlFENSTERS Matrix
Erlaubt fuumlr jeden Ausgang das Eingangssignal zu waumlhlen das als Quelle benutzt werden soll
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) AUSGANGSKANAumlLEIdentifizierung des einzustellenden Ausgangskanals
b) IDENTIFIZIERUNG DER EINGAumlNGEDen Signaltyp auswaumlhlen der nach eigener Anforderung jedem einzelnen Ausgang zugeordnet werden soll Man kann folgendes waumlhlen
In A Das Signal wird dem Eingang A zugeordnet
In B Das Signal wird dem Eingang B zugeordnet
In A+B Zuordnung der a lgebra ischen Summe der be iden Eingangssignale A und B
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
BESCHREIBUNG DES MENUumlFENSTERS Option
Erlaubt die Anzeige der Systemeinstellungen wie die Zuordnung der Ein- und Ausgaumlnge Daumlmpfung Displaykontrast und Firmware-Version
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B Src
Diese Option erlaubt die Einstellung des Audio-Signaltyps am Eingang
Analoge Audiosignale (Eingaumlnge A und B)
Digitale Audiosignale (Eingang AESEBU)
DigOut Src
An In =Audiosignale an den analogen Eingaumlngen
Dig In =Audiosignale am digitalen Eingang
OUT 1-2 =Audiosignale an den Ausgaumlngen 1 und 2
OUT 3-4 =Audiosignale an den Ausgaumlngen 3 und 4
OUT 5-6 =Audiosignale an den Ausgaumlngen 5 und 6
Input Mode
An In
Dig In
Indip =
Linked =
Diese Option erlaubt die Audioquelle zu waumlhlen die fuumlr den Steckverbinder AESEBU OUT (digitaler Ausgang) bestimmt ist
Erlaubt die Eingaumlnge zu konfigurieren
Sie sind unabhaumlngig und selbststaumlndig sie unterliegen keinen Verpflichtungen untereinander Sie sind verbunden und funktionieren im Stereo-Modus
Die Kompressoren Filter Verzoumlgerungen die Lautstaumlrke sind bei beiden Kanaumllen identisch
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
39
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
40
Atten PadZeigt an wie der Wahlschalter -6 dB auf der Ruumlckseite eingestellt ist [Ref 5] Dieser Wahlschalter muss aktiviert werden wenn das Level an den analogen Eingaumlngen zu hoch ist Der Wahlschalter wird uumlber die Taste aktiviert im Menuuml gibt es nur eine Anzeige
0dB = Wahlschalter nicht aktiviert
-6dB = Wahlschalter aktiviert
Contrast
10 heller 60 dunkler 100
Fw Vers
Die Eingangssignale sind dieselben wie die Eingangsquelle
Die Eingangssignale werden vom internen Prozessor um -6 dB gedaumlmpft
Erlaubt den Kontrast des LCD-Displays einzustellen um den Unterschied der Helligkeit auf den Installationsort auszurichten Ein deutlicheres Display erlaubt auf korrekte und schnelle Weise innerhalb der Menuumls zu surfenDie Hersteller-Einstellung am Ausgang liegt bei 60
Zeigt die Firmware-Version des Prozessors an
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
41
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
42
TECHNISCHE DATEN
Antwort in FrequenzDynamische GammaCMMRCrosstalkDistorsion
ProzessorFrequenz der DatenausarbeitungAnaloge Converter Verzoumlgerung der VerteilungSpeicherung der Konfigurationen
DisplayTastenBedienungen
Analoger Eingang ndeg2 x XLR (3-poliger Female Stecker)Impedanz des Eingangs gt10KOhmMaximales Level +21dBu ohne PAD
+27dBu bei PAD
Impedanz des Ausgangs 50OhmMaximales Level +21dBu Typ symmetrisch
Typ SPDIF-AESEBU (AES3)
Typ Entsprechend dem Standard des Eingang
Typ
Typ
NETZSPANNUNGABMESSUNGEN (BXHXT)GEWICHT
AUDIO-LEISTUNGEN+- 01dB (20 to 30kHz)116dB typgt 60dB (50 to 10kHz)lt -100dB0002 (1kHz +4dBu)
DIGITALE AUDIO-LEISTUNGEN DSP 2856-bit 48KHz24-bit BURR BROWN15ms32 preset
KONTROLLEN LCD GrafikESC - MENU - FUNCTIONS SELECTIONENTER
EIN-AUSGAumlNGE
Analoger Ausgang ndeg6 x XLR (3-poliger Male Stecker)
Digitaler Eingang ndeg1x XLR (3-poliger female Stecker)
Digitaler Ausgang ndeg1x XLR (3-poliger Male Stecker)
Ein-Ausgang Rdnet ndeg2 x XLR RJ45 (kabel CAT 5) USB Typ B
KONTROLLPARAMETER AUDIOStaumlrke -80dB a +20dB step 01dBVerzoumlgerung Eingang 0 a 729mS step 01 mS
Ausgang 0 a 340mS step 01mSPhasenrotation 0deg - 180deg
KOMPRESSIONSchwelle -80dB a +20dB step 01dBVerhaumlltnis 11 a Inf1 step 001Staumlrke am Ausgang 0dB a 40dB step 01dBAnschlusszeit 1mS a 1000mS step 01mSReleasezeit 1mS a 1000mS step 01mSBeibehaltungszeit 1mS a 1000mS step 01mS
EQUALIZER12 Equalizer fuumlr jeden Ein- und Ausgang
PEQ (parametrischer) Hi-shelf Lo-sheftFrequenz 20Hz a 20KHz step 1HzStaumlrke -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (lediglich PEQ)
FILTER CROSSOVERFilter Linkwitz Riley
HP HochdurchgangsfilterLP Bassdurchgangsfilter
Neigung 12dBoct - 24dBoct - 48dBoctSchnittfrequenz 5Hz a 20KHz step 1Hz
Full-range 100-240Vac 50-60Hz430482x43x130mm 19Kg
AnmerkungenSpezifikationen unterliegen Aumlnderungen ohne Vorankuumlndigung
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
INTRODUCTIONAC26N est un processeur audio numeacuterique pour la gestion de leacutequipement audio conccedilu pour des installations fixes et mobiles Il fonctionne selon une technologie de pointe avec des processeurs agrave 2856bits et des convertisseurs ADDA agrave 24-bits hautes performances Les fonctions du processeur sont les niveaux dentreacutee et de sortie le deacutelai (delay) la polariteacute 12 bandes deacutegalisation par canal dentreacutee et de sortie diffeacuterentes seacutelections de croisement (crossover) et un limiteur hautes performances Le controcircle des filtres a une reacutesolution de 1Hz Les entreacutees et les sorties peuvent ecirctre programmeacutees en plusieurs configurations pour satisfaire tous les besoins AC26N peut ecirctre controcircleacute en temps reacuteel et tous les paramegravetres peuvent ecirctre configureacutes depuis le pupitre frontale et par ordinateur avec interface graphique intuitive accessible via le logiciel laquoDVA Networkraquo et une connexion de reacuteseau deacutedieacutee RDnet ou USBLa mise agrave jour du logiciel pour lUniteacute centrale et DSP par ordinateur portable permet de maintenir le dispositif actualiseacute Il est possible denregistrer et de rappeler 32 configurations preacute-eacutequipeacutees de configuration
Contenu de lemballage - AC26N - Mode demploi- CD logiciel- Cacircble dalimentation
Caracteacuteristiques- 2 entreacutees et 6 sorties avec adressage flexible- Entreacutee et sortie steacutereacuteo AESEBU adressables - DSP 2856-bit- Convertisseurs AD BURR BWOWN 24-bit hautes performances- Freacutequence de reacutesolution des filtres 1 Hz - 12 eacutegaliseurs parameacutetriques pour chaque entreacutee et sortie- 2 filtres de croisement par sortie avec pente seacutelectionnable agrave 122448dBoct- DRC agrave configuration multiple hautes performances pour configuration limiteur
compression pour chaque entreacutee et sortie- Niveau reacuteglable en dB polariteacute et deacutelai pour chaque entreacutee et sortie- Mise agrave jour du micrologiciel par lordinateur- Affichage graphique agrave cristaux liquides- 32 preacutereacuteglages enregistrables par lutilisateur- Interface USB pour le controcircle et la configuration par ordinateur- Interface RDnet permettant de controcircler jusquagrave 256 dispositifs agrave distance
PC
PC
RDNETcontrol(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FONCTIONS DE LA FACE AVANT
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
COMMANDES ET FONCTIONS1) AFFICHAGE
Laffichage graphique agrave cristaux liquides permet de visualiser et deacutediter les informations de lAC26N sans utiliser lordinateur Le contraste peut ecirctre configureacute dans le menu principal
2) MANETTE Functions Selector et Push EnterCe controcircle permet de se deacuteplacer de seacutelectionner et de modifier les paramegravetres dans les menus affichables agrave leacutecranRotation de la manette (Functions Selectors)- permet de se deacuteplacer sur les diffeacuterentes pages du menu - permet de modifier les paramegravetres seacutelectionneacutesPression de la manette (Push Enter)- permet de seacutelectionnervalider les paramegravetres
3) Bouton ESC Ce controcircle permet de quitter les menus afficheacutes ou de revenir agrave la visualisation preacuteceacutedente
4) Bouton Menu Ce controcircle permet dacceacuteder directement au menu principal
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
Fra
nccedilais
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
43
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
Fra
nccedilais
44
DVA Network
AC26N est eacutequipeacute dune interface de reacuteseau proprieacutetaire deacutenommeacutee RDNET au moyen de laquelle il est possible de sinterfacer agrave lordinateur agrave travers un peacuteripheacuterique (RDNET control)
Pour cela un protocole de communication a eacuteteacute deacuteveloppeacute avec lequel il est possible de recevoir et denvoyer les donneacutees ce branchement permet de faire le monitorage en temps reacuteel des paramegravetres du diffuseur comme puissance de sortie tempeacuterature de lamplificateur eacutetat du limiteur etc Il est aussi possible de seacutelectionner diffeacuterentes eacutegalisations ou den creacuteer de nouvelles et de reacutegler les niveaux de volume souhaiteacutes au moyen dun plug-in approprieacute
On conseille de teacuteleacutecharger gratuitement le logiciel DVA Network directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
DVA USB Manager
On conseille de teacuteleacutecharger gratuitement le logiciel DVA USB Manager directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
Le micrologiciel du module amplificateur peut ecirctre remis agrave jour par le port USBPour rendre cette mise agrave jour possible et facile un programme speacutecifique a eacuteteacute deacuteveloppeacute
DOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
CONNEXIONS DU PANNEAU ARRIEgraveRE
1586 75 141210 11 13 169 17
14) Connecteur ldquo USBrdquoCe connecteur USB (type B) permet de connecter le processeur agrave un ordinateur pour le controcircle et la mise agrave jour du micrologiciel via un programme deacutedieacute (DVA Network)
15) PRISE DALIMENTATION MAINSPermet la connexion du cacircble dalimentation fourni de seacuterie
16) PORTE-FUSIBLE FUSELogement pour fusible de ligne
17) INTERRUPTEUR GENERAL POWERLinterrupteur permet de mettre en marche ou deacuteteindre le controcircleur audio
COMMANDES ET FONCTIONS
5) SELECTEUR ldquo-6dBrdquoLe seacutelecteur permet de reacuteduire de 6dB les niveaux dentreacutee analogiques XLR [6] tout en compensant les niveaux eacuteleveacutes de sortie des meacutelangeurs ou dautres dispositifs audio Quand la barre du niveau de signal des entreacutees sur laffichage [1] reste au maximum cela indique que le niveau du signal entrant est eacuteleveacute Il est alors conseilleacute dutiliser latteacutenuation -6dBIl est possible de veacuterifier quand le seacutelecteur est activeacute par le menu Option
6) CONNECTEURS DENTREE ldquoArdquo ET ldquoBrdquoEntreacutees eacutequilibreacutees au niveau de la ligneIls sont en mesure daccepter des connecteurs XLR macircles
7) CONNECTEURS DE SORTIE ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo ET ldquo6rdquoSorties eacutequilibreacutees au niveau de la ligne Ils sont en mesure daccepter des connecteurs XLR femelles
Prendre garde agrave brancher convenablement les sorties sur les diffuseurs ou les amplificateurs en fonction des configurations de chaque canal pour eacuteviter des deacutegacircts et des problegravemes de fonctionnement
Section ldquoAESEBUrdquo
8) CONNECTEUR DENTREE INOutre les entreacutees audio analogiques une entreacutee audio numeacuterique SPDIF-AESEBU (AES3) a eacuteteacute preacutevue et peut ecirctre seacutelectionneacutee par le menu de setupLentreacutee requiert une connexion eacutequilibreacutee en utilisant un connecteur XLR avec un cacircble agrave 3 conducteurs de 110ohm torsadeacute
9) CONNECTEUR DE SORTIE OUTCe connecteur permet de relancer le signal audio dans les entreacutees analogiques ou numeacuteriques ou sur les sorties La source doit ecirctre reacutegleacutee par le menu OptionLa connexion sera conforme agrave la mecircme norme que lentreacutee [reacutef8]
Section ldquoRDNETrdquo
10) CONNECTEUR DENTREE DATA INPUTConnecteur RJ45 entreacutee de donneacutees
11) CONNECTEUR DE SORTIE DATA LINKConnecteur RJ45 sortie de donneacutees pour la connexion de seacuterie en cascade
12) VOYANT LUMINEUX ONCe voyant de couleur verte sallume uniquement quand lAC26N a reconnu et est connecteacute agrave luniteacute principale RDNET par lordinateur
13) VOYANT LUMINEUX ACTIVECe voyant de couleur jaune clignote quand une transmission des donneacutees est active entre RDNET et le dispositif
PUSH
P SHU
SHPU
P SHU
PUSH
CONNEXIONS
Audio analogiquesLes connexions eacutequilibreacutees permettent de reacuteduire au minimum le bruit provoqueacute par les cacircbles et dutiliser de longs cacircblesCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLe connecteur XLR doit ecirctre brancheacute avec la broche 1 agrave la masse la broche 2 au chaud (+) et la broche 3 au froid (-) En cas de cacircble blindeacute brancher le blindage agrave la broche 1Les cacircbles de connexion XLR-XLR et XLR-Jack14(63mm) peuvent semployer pour la connexion agrave lAC26N
12
3
Entreacutee
Entreacutee
XLR - femme
XLR - femme
1 2
3
Sortie
Sortie
XLR - Macircle
XLR - Macircle
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2 = Point chaudPhase +VE
Broche 3 =Point froidPhase -VE
Broche 3 =Point froidPhase -VE
Anneau
Manchon
Pointe Point chaudPhase +VE
Anneau = Point froidPhase -VE
ManchonB Masselindeacute
Pointe
Les connexions deacuteseacutequilibreacutees peuvent semployer mecircme si le bruit provoqueacute par les cacircbles augmente Les cacircbles ne peuvent deacutepasser 5m de longCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLes connexions deacuteseacutequilibreacutees peuvent abaisser le niveau du signal entrant de 6dB Pour remeacutedier agrave cet inconveacutenient il faut brancher la broche 3 agrave la masse mecircme si cela augmente le bruit
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
45
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
46
12
3
1 2
3
Pointe Manchon
Pointe = Signal
Broche 3 = Link to Pin 1
Broche 3 = Link to Pin 1
ManchonB Masselindeacute
Audio numeacuteriques (AESEBU)
AESEBU (protocole AES3) est une entreacutee eacutequilibreacutee isoleacutee eacutelectriquement agrave laide dun transformateur Elle permet demployer deux canaux audio dans un seul cacircble bipolaire blindeacute Les caracteacuteristiques du cacircble doivent ecirctre de 3 pocircles impeacutedance 100ohm torsadeacute et blindeacute avec connecteur XLR (AES3 standard)
RJ 45
|1|2|3|4|5|6|7|8|
RDnet
Chaque port RDNet des Control 2 et Control 8 peut ecirctre brancheacute agrave un maximum de 32 dispositifs compatibles placeacutes en cascade Dans lexemple suivant le port de luniteacute de controcircle RDNET CONTROL 2 est relieacute agrave lentreacutee DATA INPUT dun AC26N dont la sortie parallegravele DATA LINK est envoyeacutee agrave lentreacutee de lAC26N successif Dans lexemple [n] est un nombre compris entre 3 et 32 (limite maximale des dispositifs que lon peut relier agrave un sous-reacuteseau)
La longueur totale du cacircble CAT5 dun sous-reacuteseau NE peut PAS deacutepasser 900 megravetres
Le connecteur doit ecirctre relieacute comme 1 ndash disponible pour dautres fonctions (par exemple audio +) 2 ndash disponible pour dautres fonctions (par exemple audio )3 ndash disponible pour dautres fonctions (par exemple masse analogique)4 ndash masse numeacuterique5 ndash masse numeacuterique6 ndash disponible pour dautres fonctions (par exemple alimentation)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
MISE EN MARCHE
Lors de la mise en marche du dispositif linitialisation deacutebute et dure quelques secondes Leacutecran affiche le modegravele le logo et la barre de progression du chargement du programme
En fin de processus dinstallation leacutecran affiche la fenecirctre du menu Meters Pour connaicirctre les indications en deacutetail consulter le paragraphe DESCRIPTION FENETRE MENU Meters
LAC26N est precirct agrave lemploi
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION ET VISUALISATION
Pour entrer dans la fenecirctre du menu principal il faut pousser sur la touche MENU ( ) agrave lavant du dispositifDune page quelconque du menu en poussant sur la touche ESCrdquo ( ) on revient automatiquement sur la page-eacutecran preacuteceacutedente
MENU PRINCIPAL
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Le processeur contient six menus Ils montrent etou configurent les paramegravetres du systegravemeLes menus principaux sont
Meters Visualisation des niveaux des entreacutees et des sorties visualisation du programme utiliseacute et eacutetat mute rapide
Preset Meacutemoriser enregistrer et eacuteliminer les configurations du systegraveme
Matrix seacutelectionner les sorties en fonction du signal entrant
Ch Job configuration de chaque signal
X-Over configurer les freacutequences de coupure et les types de filtres pour chaque sortie
Option attribution des entreacutees et des sorties contraste daffichage la version du micrologiciel les entreacutees et dautres options
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
47
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
48
DESCRIPTION DE LA FENETRE MENU Metersrdquo
Cette fenecirctre permet de visualiser les configurations et leacutetat geacuteneacuteral des entreacutees et des sorties la version du programme utiliseacute son eacutetat et le mode de pilotage du systegraveme
Les menus et les options afficheacutees peuvent se seacutelectionner en tournant la manette ldquoFUNCTIONS SETECTORrdquo ( ) Pour avoir accegraves agrave linteacuterieur de la seacutelection il faut mettre le paramegravetre souhaiteacute en eacutevidence et pousser sur la manette ldquoPush Enterrdquo ( | ) Il faut en faire de mecircme pour seacutelectionner etou modifier les options dans les commandes du menu
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositifAvec des signaux dentreacutee numeacuteriques les indications ldquoArdquo et ldquoBrdquo correspondent agrave lentreacuteeEn tournant la manette ldquoFUNCTIONS SELECTORrdquo [2] on fait deacutefiler en mode cyclique les canaux dentreacutee de sortie et lindication de mute geacuteneacuteral (d) le canal seacutelectionneacute est mis en eacutevidence
b) BARRE DE NIVEAU DE COMPRESSIONMUTE CANAL
COMPRESSION DE SIGNALLa compression du signal est visualiseacutee par le deacutefilement de la barre de droite de haut en bas
MUTE Chaque canal peut ecirctre placeacute en mute Seacutelectionner le canal et pousser sur la manette ldquoPush Enterrdquo [2] pour valider le changement deacutetat Lindication du canal sera remplaceacutee par la lettre M et la barre sera totalement mise en eacutevidencePour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterations
c) BARRE DE NIVEAU DE SIGNALLindication du niveau de chaque canal est signaleacutee par le deacutefilement de la barre de gauche
d) MUTE GENERALIl est possible de mettre simultaneacutement toutes les entreacutees et les sorties en mute Tourner la manette ldquoFUNCTIONS SELECTORrdquo seacutelectionner la lettre M et pousser sur la manette Push EnterPour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterationsLe mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) MODES DE COMMANDEIl affiche le mode dutilisation etou les dispositifs qui sont relieacutes agrave lAC26N
Local = utilisation autonome Aucune connexion agrave un dispositif exteacuterieur
NET = relieacute directement au reacuteseau deacutedieacute RDNet et agrave lordinateur
USB = relieacute directement agrave un ordinateur par cacircble USB
f) INDICATION DETAT DE PARAMETRAGECette indication permet de constater si un ou plusieurs paramegravetre(s) du programme chargeacute aont eacuteteacute modifieacute(s) par rapport au dernier sauvetage
= programme dorigine
= programme avec des paramegravetres modifieacutes
g) PROGRAMME CONFIGURELe chiffre indique le programme chargeacute et utiliseacute par le systegraveme agrave lemplacement de sauvetage Consulter le menu de Preset pour de plus amples deacutetails
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
DESCRIPTION DE LA FENETRE MENU Ch Job
Cette fenecirctre permet dafficher la configuration de chaque canal
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) NIVEAU DU SIGNALIndique le gain du signal Laugmentation de lintensiteacute dun signal est libelleacutee en deacutecibel (dB) Le paramegravetre peut ecirctre seacutelectionneacute de -8000dB agrave +2000dB avec des pas de 001dB Une augmentation de 6dB est eacutegale approximativement au redoublement agrave leacutechelle lineacuteaire du niveau du signal sous tensionAvec un gain supeacuterieur agrave 0dB le signal est amplifieacute tandis quavec un gain infeacuterieur agrave 0dB le signal est atteacutenueacute
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
49
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
50
c) DELAI DU SIGNAL (DELAY)Le signal audio reproduit peut ecirctre retardeacute pour permettre lalignement acoustique Cela compense les diffeacuterentes positions des diffuseurs pendant linstallation et la reproduction sonore Il se libelle en mS Le paramegravetre peut ecirctre seacutelectionneacute de 00mS agrave 729mS avec un pas de 01mSPour aligner un signal audio il est possible dutiliser la formule suivante
Deacutelai = (GAPx1000)344
Deacutelai = ms (en millisecondes)GAP = distance du diffuseur du point de reacutefeacuterence (en megravetres)Vitesse du son = 344ms
d) MUTEChaque canal peut ecirctre placeacute en mute La mecircme commande peut ecirctre activeacutee dans la fenecirctre du menu meters NB Le mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) PhasePermet la rotation de phase de 180deg par rapport au signal entrantCette rotation permet loptimisation surtout des basses freacutequences dans les installations complexes
f) EGALISATIONCette commande ouvre la fenecirctre du menu deacutegalisation de chaque canal Elle sert surtout pour corriger une ou plusieurs freacutequences qui doivent ecirctre atteacutenueacutees ou augmenteacutees
M M
LAC26N gegravere 12 filtres par canal dentreacutee et sortie avec trois types de configurations diffeacuterentes - Leacutegaliseur PEQ (peaking equalizer) est ideacuteal pour identifier isoler et
corriger une seule plage de freacutequences bien deacutetermineacutee Toutes les freacutequences passent mais il augmente ou diminue uniquement celles autour de la freacutequence centrale pour une bande preacutecise et un gain deacutefini
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessus de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessous de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
f Numeacuterotation des 12 filtres disponibles pour cette entreacutee ou cette sortie1
f Le type de filtre est afficheacute 2
Dis Deacutesactiveacute (absent)
PEQ Peaking equlizer
Sh H Filtre high-shelf
Sh L Filtre high-shelf
Exemples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
REMARQUELe paramegravetre Bw deacutetermine le champ de freacutequences adjacent agrave la freacutequence configureacutee ougrave est activeacute le filtre Plus la valeur Bw est eacuteleveacutee plus vaste est le champ de freacutequences (1Bw=1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONCette commande ouvre la fenecirctre du menu de compression de chaque canal
g1) TresholdIdentifie le seuil ougrave commence le rapport de compression La valeur de base 11
g2) RatioIndique le rapport de conversion entre le signal entrant et le signal sortant
g3) Post Gain Attach Release HoldCes donneacutees deacutependent du rapport de conversion que lon veut obtenir - Post Gain est le gain de sortie- Attack est le temps dattaque - Release est le temps de relacircchement- Hold est le temps de maintien
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
52
DESCRIPTION DE LA FENETRE MENU Preset
Cette fenecirctre permet de meacutemoriser jusquagrave 32 configurations dans lAC26NLe fabricant fournit le systegraveme avec un programme configureacute et enregistreacute en position 0 et non susceptible deacutecrasement
032 Elle indique lemplacement de sauvetage de la configurationCe numeacutero apparaicirct dans la fenecirctre Meters en position (g) A tout moment le programme utiliseacute peut ecirctre afficheacute par lutilisateur
Empty Preset Cest le nom qui est associeacute au numeacutero de lemplacement quand aucune configuration (vide) nest enregistreacutee
Local preset Local preset est le nom qui est associeacute au numeacutero de lemplacement quand on enregistre une configuration NB = Il est possible denregistrer une configuration avec lenom souhaiteacute de 16 lettres tout au plus agrave condition que lonutilise linterface via lordinateur
Le nom du programme assigneacute est indiqueacutePour toucher agrave lapplication 3 choix soffrent agrave vous
Save Le programme est enregistreacute en meacutemoire de lAC26N
Del Le programme est effaceacute
Load Le programme est chargeacute et precirct agrave lemploi
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
51
DESCRIPTION DE LA FENETRE MENU X-Over
Cette fenecirctre permet de seacutelectionner un filtre passe bas un filtre passe haut ou par la combinaison des deux de creacuteer un filtre passe bande pour chaque sortieLe filtre actif est un Linkwitz-Riley qui permet de seacutelectionner la pente de 12dBoct 24dBoct ou 48dBoct et sa freacutequence de coupure
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) CANAUX DE SORTIE
Les connecteurs de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) FILTRE CROSSOVERSeacutelectionner le filtre selon les besoins Il est possible de seacutelectionner
Dis Aucun filtre activeacute
HP Filtre passe-haut laisse passer uniquement la partie de signal audio supeacuterieure agrave la freacutequence de coupure
LP Filtre passe-bas laisse passer uniquement la partie de signal audio infeacuterieure agrave la freacutequence de coupure
Configuration du filtre Passe-haut Passe-bas
Rien Dis Dis
Passe-haut HP Dis
Passe-bas Dis LP
Passe-bande HP LP
12dBoct
24dBoct
Hz
dB
Ga
in 48dBoct
12dBoct
24dBoct
Hz
dB
Ga
in
48dBoct
c) PENTE DATTENUATIONSeacutelectionner la pente datteacutenuation du signal audio en fonction de la diminution que lon veut obtenir Plus la pente datteacutenuation est eacuteleveacutee agrave eacutegaliteacute de freacutequence de coupure plus eacuteleveacutee sera la seacutelection du signal Il est possible de seacutelectionner
12 correspond agrave 12dboct
24 correspond agrave 24dboct
48 correspond agrave 48dboct
d) FREQUENCE DE COUPUREElle permet de reacutegler la freacutequence de passage des freacutequences infeacuterieures (filtre passe-bas) ou des freacutequences supeacuterieures (filtre passe-haut) uniquementLe choix de la coupure deacutepend de la reproduction que lon veut obtenirLuniteacute de mesure utiliseacutee est lHz
Hz
Hz
dB
dB
Ga
in
f0
f0
0dB0dB
0dB
-6dB
freacutequence
freacutequence
freacutequence
freacutequence
Ga
in
f0
0dB
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
53
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
54
DESCRIPTION DE LA FENETRE MENU Matrix
Elle permet de seacutelectionner le signal entrant agrave utiliser comme source pour chaque sortie
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) CANAUX DE SORTIEIdentification du canal sortant agrave reacutegler
b) IDENTIFICATIONS DES ENTREESSeacutelectionner le type de signal agrave associer agrave chaque sortie en fonction des besoins Il est possible de seacutelectionner
In A Le signal entrant A est associeacute
In B Le signal entrant B est associeacute
In A+B La somme algeacutebrique des deux signaux entrants A et B est associeacutee
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
DESCRIPTION DE LA FENETRE MENU Option
Permet dafficher les reacuteglages du systegraveme comme lassignation des entreacutees et des sorties latteacutenuation le contraste de laffichage et la version du logiciel
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcCette option permet de reacutegler le type de signal audio entrant
An In =signaux audio analogiques (entreacutees ldquoArdquo et ldquoBrdquo)
Dig In =signaux audio numeacuteriques (entreacutee AESEBU)
DigOut SrcCette option permet de seacutelectionner la source audio qui sera adresseacutee sur le connecteur AESEBU OUT (sortie numeacuterique)
An In = signaux audio des entreacutees analogiques
Dig In =signaux audio sur lentreacutee numeacuterique
OUT 1-2 = signaux audio sur les sorties 1 et 2
OUT 3-4 = signaux audio sur les sorties 3 et 4
OUT 5-6 = signaux audio sur les sorties 5 et 6
Input ModePermet de configurer les entreacutees
Indip = sont indeacutependantes et autonomes Ne sont soumises agrave aucun type de lien
Linked = sont unies et fonctionnent en mode steacutereacuteo Les compresseurs les filtres les deacutelais le volume sont identiques pour les deux canaux
Atten PadIndique le mode de reacuteglage du seacutelecteur ldquo-6dBrdquo placeacute agrave larriegravere [reacutef 5] Il faut activer ce seacutelecteur quand les niveaux dentreacutee analogiques sont trop eacuteleveacutes Le seacutelecteur sactive uniquement par le bouton Dans le menu il sagit dune simple visualisation
0dB = seacutelecteur non activeacute Les signaux dentreacutee sont identiques agrave la source entrante
-6dB = seacutelecteur activeacute Les signaux entrants sont atteacutenueacutes de -6dB par le processeur interne
ContrastIl permet de reacutegler le contraste de laffichage agrave cristaux liquides pour compenser la diffeacuterence de luminositeacute avec le lieu dinstallation Une plus grande clarteacute de laffichage permet de naviguer convenablement et rapidement dans les menusLe reacuteglage agrave la sortie de lusine du fabricant est de 60
10 plus clair 60 plus fonceacute 100
Fw VersIndique la version du logiciel du processeur
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
55
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
56
DONNES TECHINIQUES
PERFORMANCES AUDIOReacuteponse en freacutequence +- 01dB (20 to 30kHz)Plage dynamique 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsion 0002 (1kHz +4dBu)
PERFORMANCES AUDIO NUMERIQUES Processeur DSP 2856-bit Freacutequence de traitement des donneacutees 48KHzConvertisseurs analogiques 24-bit BURR BROWNDeacutelai de propagation 15msMeacutemorisations des configurations 32 preset
CONTROLES Affichage LCD graficoBoutonsCommandes ESC - MENU - FUNCTIONS SELECTION
ENTERENTREESSORTIESEntreacutee analogique ndeg2 x XLR (3 broches femelle)
Impeacutedance dentreacutee gt10KOhmNiveau maximum +21dBu senza PAD
+27dBu con PADSortie analogique ndeg6 x XLR (3 broches macircle )
Impeacutedance de sortie 50OhmNiveau maximum +21dBuType Balanceacute
Entreacutee numeacuterique ndeg1x XLR (3 broches femelle)Type SPDIF-AESEBU (AES3)
Sortie numeacuterique ndeg1x XLR (3 broches macircle )Type conforme agrave la norme de lentreacutee
EntreacuteesSortie Rdnet ndeg2 x XLR RJ45 (cacircble CAT 5)USB Type B
PARAMETRES DE CONTROLE DU SONGain -80dB a +20dB eacutetape 01dBDeacutelai Entreacutee 0 a 729mS eacutetape 01 mS
Sortie 0 a 340mS eacutetape 01mSRotation de phase 0deg - 180deg
COMPRESSIONSeuil -80dB a +20dB eacutetape 01dBRapport 11 a Inf1 eacutetape 001Gain agrave la sortie 0dB a 40dB eacutetape 01dBTemps dattaque 1mS a 1000mS eacutetape 01mSTemps de relacircchement 1mS a 1000mS eacutetape 01mSTemps de maintien 1mS a 1000mS eacutetape 01mS
EGALISEURS12 eacutegaliseurs pour chaque entreacutee et sortieType PEQ (parameacutetrique) Hi-shelf Lo-sheft
Freacutequence 20Hz a 20KHz eacutetape 1HzGain -30dB a +15dB eacutetape 001dBBande 005dB a 2dB eacutetape 001dB (uniquement pour PEQ)
FILTRES CROSSOVERFiltre Linkwitz Riley
Type HF high-shelfLF low-shelf
Pente 12dBoct - 24dBoct - 48dBoctFreacutequence de coupure 5Hz a 20KHz eacutetape 1Hz
ALIMENTATION Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)POIDS 19Kg
Remarques Speacutecifications sujettes agrave modifications sans preacuteavis
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
2 VIE ATTIVO2 WAY ACTIVE
3 VIE PASSIVO3 WAY PASSIVE
L
L
A
A
HIGH L
MID L
LOW HIGHMID RHIGHMID L
LOW L
HIGH R
MID R
LOW R
R
R
B
B
1
1
2
2
3
3
456
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
Menu Matrix configurationMatrix
57 58
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
EROUIG ATRIX TNM
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
OU
TP
UT
1
OU
TP
UT
2
OU
TP
UT
3
OU
TP
UT
4
OU
TP
UT
5
OU
TP
UT
6
AE
S-E
BU
OU
TP
UT
INP
UT
A
AE
S-E
BU
INP
UT
INP
UT
B
D D D D D D
D D
A A A A A A
A SA
MP
LE
RA
TE
CO
NV
A
LIN
KA
BL
E
SC
HE
MA
A B
LO
CC
HI -
BL
OC
K D
IAG
RA
MB
LO
CK
SC
HA
LT
BIL
D -
SC
HE
MA
S F
ON
CT
ION
NE
LS
LINE ARRAY SUB MONO ATTIVO
LINE ARRAY SUB MONO ACTIVEINGRESSI - INPUT
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
L
L
L
A
A
A
AESEBU IN
AESEBU IN
AESEBU IN
AESEBU OUT
AESEBU IN
AESEBU IN
AESEBU OUT
R
R
R
LR
B
B
B
123456
HIGHMID L
HIGHMID L HIGHMID R
HIGHMID R
LOW L LOW R
LAYER
DISPLAY MEMORY
FADER MODE
LAYER
DISPLAY MEMORY
FADER MODE
Ingresso ANALOGICO
ANALOG Input
Collegamento in cascata
Link connections
Ingresso DIGITALE
DIGITAL inputA B
BALANCED AUDIO INPUTS
-6dB
PUSH PUSH
IN OUT
AES EBUPUSH
Oppure
or
Oppure
or
Menu Option configurationOption
Menu Option configurationOption Menu Option configurationOption
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type Analog
AES out An In
Input type Analog
AES out An In
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
59 60
InA-B Src Dig InInA-B Src Dig InInA-B Src An InInA-B Src An In
frequenzaHz
dB
Gu
ad
ag
no
60 200 2800
0dB0dB
-6dB
Esempio di un sistema a 3-vie
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
Out 1 Out 2 Out 3
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Esempio di un sistema a 3-vie
61 62
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
26NAC 26NAC
R TE
DO
R
MO LEU O R CE S
E O TR L A
S O
O C ND I P
P hsuernE t
o su cti nF nel rS e tc o
E CSME UN
IGCHTE OL SN EOBd
ocaL l
M
0
484
467
430
44
31
75
12
7
DIMENSIONI DIMENSIONSABMESSUNGEN DIMENSIONS
Audio digitali (AESEBU)AESEBU (protocollo AES3) egrave un ingresso bilanciato isolato elettricamente tramite un trasformatore Permette di utilizzare due canali audio in un singolo cavo bipolare schermato Le caratteristiche del cavo devono essere impedenza 100ohm twistato e schemato con connettore XLR (AES3 standard)
RD netCiascuna porta RDNet presente sui Control 2 e Control 8 puograve essere collegata a max 32 dispositivi compatibili posti in cascata
Nellrsquoesempio a seguito la porta dellunitagrave di controllo RDNET CONTROL 2 egrave collegata allingresso DATA INPUT di un AC 26N la cui uscita parallela DATA LINK egrave inviata allingresso del successivo AC26N Nellesempio [n] egrave un numero compreso tra 3 e 32 (limite massimo dei dispositivi da collegare ad una sotto rete)
RJ 45
|1|2|3|4|5|6|7|8|
La lunghezza complessiva del cavo CAT5 di una sotto rete NON puograve eccedere i 900 metri
Il connettore deve essere collegato come
1 ndash disponibile per altre funzioni (ad esempio audio +) 2 ndash disponibile per altre funzioni (ad esempio audio ndash)3 ndash disponibile per altre funzioni (ad esempio massa analogica)4 ndash massa digitale5 ndash massa digitale6 ndash disponibile per altre funzioni (ad esempio alimentazione)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
ACCENSIONEAllrsquo accensione del dispositivo si avvia lrsquoinizializzazione che dura alcuni secondi Sul display viene visualizzato il modello il logo e la barra avanzamento caricamento del programma
Al termine del processo di installazione sul display viene visualizzata la finestra del menugrave ldquoMetersrdquo Per conoscere le indicazioni nel dettaglio fare riferimento al paragrafo ldquoDESCRIZIONE FINESTRA MENUrsquo ldquoMetersrdquo
AC26N egrave pronto per lrsquoutilizzo
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquouso
Ma
nu
ale
drsquou
so
5
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquouso
Ma
nu
ale
drsquou
so
6
A B 1 2 3 4 5 6
CONFIGURAZIONE E VISUALIZZAZIONEPer accedere alla finestra del menugrave principale egrave necessario premere il tasto ldquoMENUrdquo ( ) posto sul frontale del dispositivo
ldquoESCrdquo ( ) Da una qualunque pagina del menu premendo il tasto si torna automaticamente alla schermata precedente
MENUrsquo PRINCIPALE
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
I menugrave presenti nel processore sono sei e mostrano eo configurano i parametri del sistemaI menugrave principali sono
Meters visualizzazione livelli degli ingressi e delle uscite visualizzazione programma utilizzato e stato mute rapido
Preset memorizzare salvare ed eliminare le configurazioni del sistema
Matrix selezionare le uscite in funzione del segnale in ingresso
Ch Job configurazione di ogni singolo canale
X-Over configurare le frequenza di taglio e i tipi di filtri per ogni singola uscita
Option assegnazione degli ingressi e delle uscite contrasto display la versione del firmware ingressi ed altre opzioni
I menugrave e le singole opzioni visualizzati possono essere selezionati ruotando la manopolaldquoFUNCTIONS SETECTORrdquo ( ) Per accedere allrsquointerno della selezione egrave necessario evidenziare il parametro desiderato e premere la manopola ldquoPush Enterrdquo ( |) Lo stesso procedimento deve essere adottato per selezionare eo modificare le opzioni alrsquointerno delle voci del menugrave stesso
DESCRIZIONE FINESTRA MENUrsquo ldquoMetersrdquoQuesta finestra permette di visualizzare le configurazioni e lo stato generale degli ingressi e delle uscite la versione del programma utilizzato il suo stato e come viene pilotato il sistema
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
7
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
8
a) CANALI INGRESSO E USCITAI connettori di ingresso ed uscita sono identificati utilizzando le medesime indicazioni presenti sulla serigrafia del retro del dispositivoCon segnali di ingresso digitali lrsquoindicazione ldquoArdquo e ldquoBrdquo corrispondono allrsquoingressoRuotando la manopola ldquoFUNCTIONS SELECTORrdquo [2] si scorrono in modo ciclico i canali ingresso uscita e indicazione di mute generale (d) il canale selezionato viene evidenziato
COMPRESSIONE SEGNALELa compressione del segnale viene visualizzata tramite lo scorrimento della barra di destra dallrsquoalto verso il basso
MUTE Ogni singolo canale puograve essere posto nelle condizione di mute Selezionare il canale e premere la manopola ldquoPush Enterrdquo [2] per confermare il cambiamento di stato Alla indicazione del canale verragrave sostituita la lettera ldquoMrdquo e la barra verragrave completamente evidenziataPer ripristinare il funzionamento normale ripetere le precedenti azioni descritte
c) BARRA LIVELLO SEGNALELrsquoindicazione del livello di ogni singolo canale viene segnalato tramite lo scorrimento delle barra di sinistra
d) MUTE GENERALEErsquo possibile mettere in mute tutti gli ingressi e le uscite contemporaneamente Ruotare la manopola ldquoFUNCTIONS SELECTORrdquo [2] selezionare la lettera ldquoMrdquoe premere la manopola ldquoPush Enterrdquo [2]Per ripristinare il funzionamento normale ripetere le precedenti azioni descritteIl mute generale ha la prioritagrave piugrave alta rispetto ai mute dei singoli canali
b) BARRA LIVELLO COMPRESSIONEMUTE CANALE
e) MODALITArsquo DI COMANDOViene visualizzato come egrave utilizzato eo a quali dispositivi egrave collegato lrsquo AC26N
Local = utilizzo stand-alone Nessuna connessione ad un dispositivo esterno
NET = collegato direttamente alla rete dedicate RDnet e al computer
USB = collegato direttamente ad un computer tramite cavo USB
f) INDICAZIONE STATO IMPOSTAZIONITramite questa indicazione viene visualizzato se il programma caricato egrave stato modificato in uno o piugrave parametri rispetto allrsquoultimo salvataggio
= programma originale
= programma con parametri modificati
g) PROGRAMMA IMPOSTATOIl numero indica il programma caricato ed utilizzato dal sistema riferito alla locazione di salvataggio Fare riferimento al menugrave di ldquoPresetrdquo per ulterioi dettagli
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
DESCRIZIONE FINESTRA MENUrsquo ldquoCh Jobrdquo
Questa finestra permette di visualizzare la configurazione di ogni singolo canale
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) CANALI INGRESSO E USCITAI connettori di ingresso ed uscita sono identificati utilizzando le medesime indicazioni presenti sulla serigrafia del retro del dispositivo
b) LIVELLO DEL SEGNALEIndica guadagno del segnale Laumento nella intensitagrave di un segnale egrave espresso in decibel (dB) Il parametro puograve essere selezionato da -8000dB a +2000dB con passi di 001dB Un aumento di 6dB egrave approssimativamente uguale al raddoppiamento in scala lineare del livello in tensione del segnaleCon un guadagno maggiore di 0dB viene amplificato il segnale mentre con un guadagno inferiore di 0dB viene attenuato il segnale
c) RITARDO DEL SEGNALE (DELAY)I segnale audio riprodotto puograve essere ritardato per permettere lrsquoallineamento acustico Questo compensa le diverse posizioni dei diffusori durante lrsquoinstallazione e la riproduzione sonora ed egrave espresso il mS Il parametro puograve essere selezionato da 00mS a 729mS con passo 01mSPer allineare un segnale audio egrave possibile utilizzare la seguente formula
Ritardo = (GAPx1000)344
Ritardo = ms (espresso in millisecondi)GAP = distanza del diffusore dal punto di riferimento (espresso in metri)
Velocitagrave del suono = 344ms
d) MUTEOgni singolo canale puograve essere posto nella condizione di mute Lo stesso comando puograve essere attivato nella finestra del menugrave laquometersraquo NB Il mute generale ha la prioritagrave piugrave alta rispetto ai mute dei singoli canali
e) FASEPermette la rotazione di fase di 180deg rispetto al segnale in ingressoQuesta rotazione permette lrsquoottimizzazione soprattutto delle basse frequenze nelle installazioni complesse
f) EQUALIZZAZIONEQuesto comando apre la finestra del menugrave dellrsquoequalizzazione del singolo canale Viene principalmente utilizzato per correggere una o piugrave frequenze che devono essere attenuate oppure aumentate
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
109
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
oLrsquo AC26N gestisce 12 filtri per ogni singolo canale di ingresso e uscita con tre diversi tipi configurazioni
Passano tutte le frequenze ma aumenta e diminuisce solo quelle attorno alla frequenza centrale per una determinata banda e un guadagno stabilito
- Equalizzatore high-shelf passa tutte le frequenze ma aumenta o attenua le frequenze sopra la frequenza di taglio selezionata per il guadagno indicato
- Equalizzatore low-shelf passa tutte le frequenze ma aumenta o attenua le frequenze inferiori alla frequenza selezionata per il guadagno indicato
- Equalizzatore PEQ (peaking equalizer) egrave ideale per identificare isolare e correggere solo una determinata gamma di frequenze
f Numerazione dei 12 filtri disponibili per quellrsquoingresso oppure uscita1
f Viene visualizzato il tipo di filtro2
Dis Disinserito (non presente)
PEQ Peaking equalizer
Sh H Filtro high-shelf
Sh L Filtro low-shelf
Esempi PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
NOTA BENEIl parametro Bw determina il campo di frequenze adiacenti alla frequenza impostata dove viene attivato il filtro maggiore egrave il valore Bw maggiore e egrave il campo di frequenze (1Bw=1 ottava)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONEQuesto comando apre la finestra del menugrave compressione del singolo canale
g ) Treshold1
Identifica la soglia dove inizia il rapporto di compressione Il valore di base 11
g ) Ratio2
Indica il rapporto di conversione tra il segnale in ingresso e quello in uscita
g ) Post Gain Attach Release Hold3
Questi dati sono in funzione del rapporto di conversione che si vuole ottenerePost Gain egrave il guadagno di uscitaAttack egrave il tempo di attacco Release egrave il tempo di rilascioHold il tempo di mantenimento
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
DESCRIZIONE FINESTRA MENUrsquo ldquoPresetrdquoQuesta finestra permette di memorizzare fino a 32 configurazioni nellrsquoAC26NLa ditta costruttrice fornisce il sistema con un programma impostato e salvato nella posizione ldquo0rdquo e non sovrascrivibile
032 Indica la locazione di salvataggio della configurazioneQuesto numero appare anche nella finestra ldquoMetersrdquo nella posizione (g) in qualsiasi momento il programma utilizzato puograve essere visualizzato dellrsquoutente
Empty Preset Ersquo il nome che viene associato al numero della locazione quando non egrave salvato nessun settaggio (vuoto)
Local preset Ersquo il nome che viene associato al numero di locazione quando viene salvata una configurazione NB = Ersquo possibile salvare un settaggio con il nome desiderato al max 16 lettere solo utilizzando lrsquointerfaccia tramite il computer
Selezionando un programma appare la seguente finestra
Viene indicato il nome del programma assegnatoPer intervenire sulla applicazione sono a disposizione 3 scelte possibili
Save Il programma viene salvato nella memoria dellrsquoAC 26N
Del Il programma viene cancellato
Load Il programma viene caricato e pronto per essere utilizzato
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
11
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
12
DESCRIZIONE FINESTRA MENUrsquo ldquoX-OverrdquoQuest a finestra permette di selezionare per ogni uscit a un filtro p assa basso un filtro p assa alto oppure tramite la combinazione di entrambe creare un filtro p assa bandaIl filtro presente egrave un Linkwitz-Riley dove egrave possibile selezionare la pendenza di 12dBoct 24dBoct oppure 48dBoct e la relativa frequenza di t aglio
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) CANALI USCITA
I connettori di uscita sono identificati utilizzando le medesime indicazioni presenti sulla serigrafia del retro del dispositivo
b) FILTRO CROSSOVERSelezionare il filtro a seconda delle necessitagrave Ersquo possibile selezionare
Dis Nessun filtro attivato
HP Filtro passa-alto lasciare passare solo la parte di segnale audio superiore alla frequenza di taglio
LP Filtro passa-basso lasciare passare solo la parte di segnale audio inferiore alla frequenza di taglio
Configurazione Filtro Passa basso Passa alto
Nessuna Dis Dis
Passa alto HP Dis
Passa basso Dis LP
Passa banda HP LP
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
c) PENDENZA DI ATTENUAZIONESelezionare la pendenza di attenuazione del segnale audio in base alla diminuzione che si desidera ottenere Piugrave elevata egrave la pendenza di attenuazione a paritagrave di frequenza di taglio maggiore egrave la selezione del segnale Ersquo possibile selezionare
12 corrisponde a 12dboct
24 corrisponde a 24dboct
48 corrisponde a 48dboct
d) FREQUENZA DI TAGLIOPermette drsquoimpostare la frequenza di passaggio delle sole frequenze inferiori (filtro passa-basso) o delle sole frequenze superiori (filtro passa-alto)La scelta del taglio egrave in funzione della riproduzione che si vuole ottenereLrsquounitagrave di misura utilizzata egrave Hz
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
DESCRIZIONE FINESTRA MENUrsquo ldquoMatrixrdquoPermette di selezionare per ogni uscita il segnale in ingresso da utilizzare come sorgente
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) CANALI USCITAIdentificazione del canale in uscita da impostare
b) IDENTIFICAZIONI INGRESSISelezionare il tipo di segnale da abbinare a ogni singola uscita in base alle proprie necessitagrave Ersquo possibile selezionare
In A Viene associato il segnale in ingresso laquoAraquo
In B Viene associato il segnale in ingresso laquoBraquo
In A+B Viene associato la somma algebrica dei due segnali in ingresso laquoAraquo e laquoBraquo
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
DESCRIZIONE FINESTRA MENUrsquo ldquoOptionrdquoPermette di visualizzare le impostazioni sistema come lrsquoassegnazione degli ingressi e delle uscite attenuazione il contrasto del display e la versione del firmware
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711
InA-B SrcQuesta opzione permette di impostare il tipo di segnale audio in ingresso
An In = segnali audio analogici (ingressi ldquoArdquo e ldquoBrdquo)
Dig In = segnali audio digitali (ingresso AESEBU)
DigOut SrcQuesta opzione permette di selezionare la sorgente audio che verragrave indirizzata sul connettore AESEBU OUT (uscita digitale)
An In = segnali audio presenti negli ingressi analogici
Dig In = segnali audio presenti sullrsquoingresso digitale
OUT 1-2 = segnali audio presenti sulle uscite 1 e 2
OUT 3-4 = segnali audio presenti sulle uscite 3 e 4
OUT 5-6 = segnali audio presenti sulle uscite 5 e 6
Input ModePermette di configurare gli ingressi
Indip = sono indipendenti ed autonomi non sono soggetti a vincoli di alcun genere tra di loro
Linked = sono uniti e funzionano in modalitagrave stereoI compressori i filtri i ritardi il volumesono identici per i due canali
13
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
14
Atten Pad
Indica come egrave impostato il selettore ldquo-6dBrdquo posto sul retro [rif 5] Ersquo necessario attivare questo selettore quando i livelli di ingresso analogici sono troppo elevati Il selettore viene attivato solo tramite il pulsante nel menugrave egrave solo una visualizzazione
0dB = selettore non attivatoI segnali di ingresso sono i medesimi della sorgente in ingresso
-6dB = selettore attivatoI segnali in ingresso vengono attenuati di -6dB dal processore interno
Contrast
Consente di regolare il contrasto del display LCD per compensare la differenza di luminositagrave con il luogo di installazione Una maggiore chiarezza del display permette di navigare allrsquointerno dei menugrave in modo corretto e veloceIl settaggio in uscita dalla ditta produttrice egrave 60
10 piugrave chiaro 60 piugrave scuro 100
Fw Vers
Indica la versione del firmware del processore
SPECIFICHE TECNICHE
PRESTAZIONI AUDIORisposta in frequenza +- 01dB (20 to 30kHz)Gamma dinamica 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsione 0002 (1kHz +4dBu)
PRESTAZIONI AUDIO DIGITALI Processore DSP 2856-bit Frequenza elaborazione dati 48KHzConvertitori analogici 24-bit BURR BROWNRitardo di propagazione 15msMemorizzazioni configurazioni 32 preset
CONTROLLI Diplay LCD graficoPulsantiComandi ESC - MENU - FUNCTIONS SELECTION
ENTER
INGRESSIUSCITEIngresso analogico ndeg2 x XLR (3 poli femmina)
Impedenza di ingresso gt10KOhmLivello massimo +21dBu senza PAD
+27dBu con PADUscita analogica ndeg6 x XLR (3 poli maschio)
Impedenza di uscita 50OhmLivello massimo +21dBu Tipo Bilanciato
Ingresso digitale ndeg1x XLR (3 poli femmina)Tipo SPDIF-AESEBU (AES3)
Uscita digitale ndeg1x XLR (3 poli maschio)Tipo conforme allo standard dellrsquoingresso
IngressiUscita RDnet ndeg2 x XLR RJ45 (cavo CAT 5)USB Tipo B
PARAMETRI CONTROLLO AUDIOGuadagno -80dB a +20dB passo 01dBRitardo
ingresso 0 a 729mS passo 01 mSuscita 0 a 340mS passo 01mS
Rotazione di fase 0deg - 180deg
COMPRESSIONESoglia -80dB a +20dB passo 01dBRapporto 11 a Inf1 passo 001Guadagno in uscita 0dB a 40dB passo 01dBTempo di attacco 1mS a 1000mS passo 01mSTempo di rilascio 1mS a 1000mS passo 01mSTempo di mantenimento 1mS a 1000mS passo 01mS
EQUALIZZATORI12 equalizzatori per ogni ingresso e uscitaTipo PEQ (parametrico) Hi-shelf Lo-sheft
Frequenza 20Hz a 20KHz passo 1HzGuadagno -30dB a +15dB passo 001dBBanda 005dB a 2dB passo 001dB (solo per PEQ)
FILTRI CROSSOVERFiltro Linkwitz Riley
Tipo HP Passa-AltoLP Passa-Basso
Pendenza 12dBoct - 24dBoct - 48dBoctFrequenza di taglio 5Hz a 20KHz passo 1Hz
ALIMENTAZIONE Full-range 100-240Vac 50-60HzDIMENSIONI 430482x43x130mm (LxHxD)PESO 19Kg
Note Specifiche soggette a variazioni senza preavviso
CLASSIFICAZIONE EMIIn accordo alle normative EN 55103 lapparato egrave progettato e idoneo allutilizzo in ambienti Elettromagnetici E3 o inferiori (E2 E1)
INTRODUCTIONAC26N is a digital sound processor for the management of audio systems designed for fixed and touring installations AC26N uses the most modern technology with 2856 bit processors and high performance 24 bits ADDA converters The functions available in the processor are input and output levels delay polarity 12 equalization bands for each input and output channel multiple crossover and high performance limiter The control resolution of the filters is 1Hz Inputs and outputs can be set according to many configurations to meet any need AC26N can be controlled in real time and each one of its parameters can be configured on the front panel and through a computer by means of an intuitive graphical interface accessible through the software DVA Network and a dedicated RDnet or USB network connectionThe CPU and DSP software update via PC allows to keep the device up to date It is possible to save and recall 32 preset configurations
Package Contents- AC26N - Operating manual- Software CD- Power cord
Characteristics- 2 Inputs and 6 Outputs with flexible routing- AESEBU addressable stereo inputs and outputs - 2856 bit DSP- BURR-BROWN high performance 24 bit AD converters- Frequency resolution of the filters 1 Hz - 12 parametric equalizers for each input and output- 2 crossover filters for each output with selectable slope 122448 dBoct- High performance DRC multi configuration for limitercompression configuration of
each input and output- Adjustable level in dB polarity and delay for each input and output- Firmware Update via PC- Graphic LCD Display- 32 pre-sets can be stored by the user- USB interface for configuration and control via computer- RDnet interface that allows to control up to 256 remote devices
PC
PC
RDNET hub(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FUNCTIONS FRONT PANEL
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
CONTROLS AND FUNCTIONS
1) DISPLAYThe graphic LCD display allows to view and edit the AC26N information without a computer The display contrast can be set within the main menu
2) ldquoFunctions Selectorrdquo and ldquoPush Enterrdquo KNOBThis control allows to move select and change the parameters within the displayed menusRotation of the knob (Function Selector)- it allows to browse the menu pages- it allows to change the selected parametersPush the knob (Push Enter)- it allows to selectconfirm the parameters
3) ESC button This control allows to exit the displayed menus or to return to the previous view
4) MENU button This control allows to directly access the main menu
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
En
glis
hE
nglis
hu
ser
man
ual
user
man
ual
16
user
man
ual
user
man
ual
Englis
hE
nglis
h
15
DVA USB Manager
The firmware of the amplifier module can be updated via the USB portTo make this update possible and simple a dedicated program has been developed
It is recommended to download DVA USB Manager free software directly from dB Technologies (wwwdbtechnologiescom) in the special section laquoSoftware amp Controllerraquo
DVA Network
The AC26N is equipped with proprietary network interface called RDNET for PC interface through a device (RDNET control)For this purpose a proprietary communication protocol has been developed for receiving and sending data this connection permits real-time monitoring of the diffuser parameters such as output power amplifier temperature limiter status etc It is also possible to select various equalizations or create new ones set the desired volume levels using the specific plug-in
It is recommended to download DVA Network free software directly from dB Technologies (wwwdbtechnologiescom) in the special section laquoSoftware amp Controllerraquo DOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
REAR PANEL CONNECTIONS
1586 75 141210 11 13 169 17
14) USB connectorThis USB connector (type B) allows to connect the processor to a compute to check and update the firmware via a dedicated program (DVA Network)
15) ldquoMAINSrdquo POWER CONNECTIONIt allows to connect the provided power cord
16) FUSE HOLDER ldquoFUSErdquoMain power supply fuse housing
17) ldquoPOWERrdquo MAIN SWITCHThis switch allows to switch on and off the device
PUSH
P SHU
SHPU
P SHU
PUSH
CONNECTIONS
Analog Audio ConnectionsBalanced connections allow to minimize the cable induced noise so cable can be longerSuch connections may be used both on inputs and outputsXLR connector must be cabled with pin 1 to ground pin 2 to hot (+) and pin 3 to cold (-) With shielded cables connect the shield to pin 1XLR-XLR e XLR-Jack 14(63 mm) connection cables can be used to connect the AC26N
12
3
Input
XLR - female
Pin 3 =NegativeCold-VE Phase
Pin 3 =NegativeCold-VE Phase
1 2
3
Output
XLR - Male
Pin 2 = PositiveHot+VE Phase
Pin 2 = PositiveHot+VE Phase
Pin 2 = PositiveHot+VE Phase
Pin 2 = PositiveHot+VE Phase
Pin 1 =ScreenGroundEarth
Pin 1 =ScreenGroundEarth
Pin 1 =ScreenGroundEarth
Pin 1 =ScreenGroundEarth
Ring
Sleeve
Tip = PositiveHot+VE Phase
Ring = NegativeCold-VE Phase
Sleeve=ScreenGroundEarth
Sleeve=ScreenGroundEarth
Tip
The unbalanced connections can also be used However the cable induced noise increases and cable length must not exceed 5 metersSuch connections may be used both on inputs and outputsUnbalanced connection may lower the level of the input signal up to 6dB in order to overcome this drawback connect pin 3 to ground although this can increase the noise
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
18
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
17
CONTROLS AND FUNCTIONS
5) -6dB SELECTORThis selector allows to reduce all the analog XLR [6] input levels by 6 dB at the same time to compensate for the high output levels on the mixers or other audio devices When the input signal level bar on the display [1] remains always at full scale this means that the input signal level is excessive and a -6 dB attenuation is recommendedIn the Option menu it is possible to check when the selector is activated
6) INPUT CONNECTORS ldquoArdquo AND ldquoBrdquoInputs balanced at line levelCapable to accept XLR male connectors
7) OUTPUT CONNECTORS ldquo1rdquo ldquo2rdquordquo 3rdquo ldquo4rdquo ldquo5rdquo AND ldquo6rdquoOutputs balanced at line level Capable to accept XLR famale connectors
Be careful to correctly connect each output to each speaker or amplifier according to the settings of each channels to avoid damages and malfunctions
ldquoAESEBUrdquo Section
8) INPUT CONNECTORIn addition to the analog audio inputs a SPDIF-AESEBU (AES3) digital audio input is also provided It can be selected via the setup menuSuch input requires a balanced connection trough an XLR connector with a 110 ohm twisted 3-wires cable
9) ldquoOUTrdquo OUTPUT CONNECTORThis connector allows to forward audio signals available at the digital or analog inputs or outputs The source must be set by means of the Option menuThe connection must comply with the same standard of the input [8]
RDNET Section
10) DATA INPUT CONNECTORData input RJ45 connector
11) ldquoDATA LINKrdquo OUTPUT CONNECTORRJ45 connector for data output used for serial link in cascade
12) ldquoONrdquo INDICATOR LIGHTThis green indicator turns on only when the AC26N has recognized the RDNET main unit and it is connected to it via computer
13) ldquoACTIVErdquo INDICATOR LIGHTThis yellow indicator flashes when data transmission between RDNET and the device is active
12
3
Input
XLR - female
1 2
3
Output
XLR - Male
Tip Gambo
Tip= Signal
Pin 3 = Link to Pin 1
Pin 3 = Link to Pin 1
Digital Audio Connections (AESEBU)AESEBU (AES3 protocol) is and a balanced input electrically insulated by means of a transformer It allows carrying two audio channels in a single two-wires shielded cable The cable characteristics are twisted 3 poles impedance 100 ohm shielded equipped with XLR connector (AES3 standard)
RDnetEach RDNet port on Control 2 and Control 8 can be connected to maximum 32 cascade-connected compatible devices In the example below the control unit RDNET CONTROL 2 port is connected to the DATA INPUT of an AC 26N whose parallel DATA LINK output is sent to the input of the next AC26N In the example [n] is a number between 3 and 32 (maximum limit for the devices connected to a sub-network)
RJ 45
|1|2|3|4|5|6|7|8|
The overall length of a CAT5 sub-network cable cannot exceed 900 meters
The connector must be connected as follows
1 - Available for other functions (for example audio +) 2 - Available for other functions (for example audio -)3 - Available for other functions (for example analog ground)4 - digital ground5 - digital ground6 - Available for other functions (for example power supply)7 - RS 485 A8 - RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
POWER ON
When the device is turned on the initialization procedure starts It lasts few seconds The display shows the device model the company logo and a program loading progress bar
At the end of the installation process the display shows the Meters menu For further details about the indications refer to the paragraph MENU DESCRIPTION - METERS
AC26N is now ready for use
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION AND DISPLAY
To access the main menu window press the MENU key located on the device front panelIn any page of the menu press the ESC button to return to the previous screen
MAIN MENU
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
There are six menus in the processor They show andor configure the system parametersThe main menus are
Meters Input and output levels display program in progress display quick muting
Preset Store save and delete the system configurations
Matrix Select the outputs according to the input signal
Ch Job Configuration of each individual channel
X-Over Configuration of the cut-off frequency and the types of filters for each output
Option Assignment of the inputs and outputs display contrast firmware version inputs and other options
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
20
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
19
The menus and the individual options displayed can be selected by rotating the knob ldquoFUNCTION SELECTORrdquo ( ) To access the selection highlight the desired parameter and press the ldquoPush Enterrdquo ( | ) knobThe same procedure should be adoptd to select andor change the options inside each menu entry
MENU DESCRIPTION - ldquoMetersrdquo
This window allows to view the configuration and the general conditions of the inputs and outputs the version of the program used the program status and how the system is driven
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) INPUT AND OUTPUT CHANNELSThe input and output connectors are identified by the same information provided on the screen printing located on the device rear sideWith digital input signals the indications A and B concern the inputBy rotating the knob FUNCTION SELECTOR [2] input channels output channels and general muting indications are cyclically scrolled (d) the selected channel is highlighted
b) BAR COMPRESSION LEVEL CHANNEL MUTING
SIGNAL COMPRESSIONSignal compression is displayed by the vertical scrolling (top to down) of the right bar
MUTE Each channel can be individually muted Select the channel and press the Push Enter knob [2] to confirm the change of status The indication of the channel will be replaced by the letter M and the bar will be completely highlightedTo restore normal operation repeat the actions described above
c) SIGNAL LEVEL BARThe level indication for each channel is provided by scrolling the left bar
d) GENERAL MUTINGIt is possible to mute all the inputs and outputs simultaneously Rotate the knob FUNCTION SELECTOR select the letter M and press the Push Enter knobTo restore normal operation repeat the actions described aboveThe general mute has the highest priority with respect to the muting of individual channels
e) CONTROL MODEIt shows how the AC26N is used andor to which devices it is connected
Local = stand-alone usage No connection to an external device
NET = directly connected to dedicated RDnet network and to computer
USB = directly connected to another computer via USB cable
f) SETTING STATUS INDICATIONThis indication shows if the loaded program was amended in one or more parameters with respect to the last saving operation
= original program
= program with modified parameters
g) SET PROGRAMThe number shows the program that is loaded and used by the system with reference to the saving position Refer to the ldquoPresetrdquo menu for further details
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
MENU DESCRIPTION - CH JOB
This window allows to view the configuration of each individual channel
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) INPUT AND OUTPUT CHANNELSThe input and output connectors are identified by the same information provided on the screen printing located on the device rear side
b) SIGNAL LEVELIt shows the signal gain The increased signal intensity is expressed in decibels (dB) Such parameter can be selected in the range from -8000 dB to +2000 dB in steps of 001 dB An increase of 6 dB is approximately equal to doubling - in a linear scale - the signal voltage levelIf the gain exceeds 0 dB the signal is amplified while if the gain is lower than 0 dB the signal is attenuated
c) SIGNAL DELAYThe reproduced audio signal may be delayed to perform an acoustic alignment This compensates for the different positions of the speakers during the installation and the sound reproduction it is expressed in ms The parameter can be selected in the range from 00 ms to 729 ms in steps of 01 msThe following formula can be used to align an audio signal
Delay = (GAPx1000)344
Delay = ms (in milliseconds)GAP = distance between speaker and reference point (in meters)Speed of sound = 344 ms
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
22
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
21
d) MUTEEach channel can be individually muted The same command can be activated in the Meters Menu
NOTE The general mute has the highest priority with respect to the muting of individual channels
e) PhaseIt performs a phase rotation of 180deg with respect to the input signalSuch phase rotation allows the optimization in special way for low frequencies in complex installations
M M
f) EQUALIZATIONThis control opens the menu controlling the single channel equalization It is mainly used to correct one or more frequencies that must be reduced or increased
The AC26N manages 12 filters for each individual channel input and output with three different kinds of configuration
- PEQ Equaliser (peaking equalizer) ideal to identify isolate and correct only a certain range of frequencies All frequencies pass only those around the centre frequency are increased and decreased for a given bandwidth and set gain
- High-shelf Equalizer All frequencies pass but frequencies above the selected cut-off frequency are increased or attenuated by the given gain
- Low-shelf Equalizer All frequencies pass but frequencies below the selected cut-off frequency are increased or attenuated by the given gain
f Numbering of the 12 available filters for the specific input or output1
f Displays the kind of filter2
Dis Switched off (not present)
PEQ Peaking equlizer
Sh H High-shelf Filter
Sh L Low-shelf Filter
Examples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
NOTE
The parameter Bw defines the range of frequencies close to the set frequency where the filter is activated the greater the value of Bw the wider is the frequencies range (1 Bw = 1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONThis control opens the menu controlling the compression for the single channel
g1) ThresholdIdentifies the starting threshold for the compression ratio Base value 11
g2) RatioIndicates the conversion ratio between input and output signal
g3) Post Gain Attach Release HoldThese data are in function of the conversion ratio to achieve Post Gain is the output gain Attack is the attack time Release is the release time Hold is the holding time
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
24
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
23
MENU DESCRIPTION - PRESET
This window allows to store up to 32 configurations in the AC26NThe manufacturer provides the system with a program set and saved in position 0 that is not possible to overwrite
032 Indicates the location where the configuration is savedThis number also appears in the window Meters in position (g) The program in use can be displayed at any time by the user
Empty Preset It is the name associated with the location number when no setting is saved (empty)
Local preset It is the name associated with the location number when a setting is saved NOTE = It is possible to save a setting with the desired name up to 16 letters only via the computer interface
When a program is selected the following window is displayed
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
The name of the assigned program is displayed3 possible choices are available when working on the application
Save The program is saved in the AC 26N memory
Del The program is deleted
Load The program is loaded and ready to be used
MENU DESCRIPTION - X-OVER
This window allows to select for each output a low pass filter a high pass filter or create a band-pass filter via the combination of bothThe available filter is a Linkwitz-Riley where it is possible to select slopes of 12 dBoct 24 dBoct or 48 dBoct and their cut-off frequency
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) OUTPUT CHANNELS
The output connectors are identified by the same information provided on the screen printing located on the device rear side
b) CROSSOVER FILTERSelect the filter according to needs It is possible to select
Dis No filter enabled
HP High-pass filter set it to allow only the part of audio signal above the cut-off frequency
LP Low-pass filter set to allow only the part of audio signal below the cut-off frequency
Filter configuration Low-pass High-pass
Nothing Dis Dis
High-pass HP Dis
Low-pass Dis LP
Band-pass HP LP
12dBoct
24dBoct
Hz
dB
48dBoct
12dBoct
24dBoct
frequency
frequency
frequency
frequency
Hz
dB
48dBoct
c) ATTENUATION SLOPESelect the attenuation slope of the audio signal on the basis of the desired attenuation The higher the attenuation slope at the same cut-off frequency the greater the signal selection It is possible to select
12 equal to 12 dBoct
24 equal to 24 dBoct
48 equal to 48 dBoct
d) CUT-OFF FREQUENCYTo set the passing frequency for the lower frequencies only (low-pass filter) or the higher frequencies only (high-pass filter)The choice of the cut-off depends on the desired sound reproductionThe unit of measurement used is Hz
Hz
Hz
dB
dB
Ga
inG
ain
Ga
inG
ain
f0
f0
0dB0dB
0dB
-6dB
-6dB
0dB
0dB
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
26
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
25
MENU DESCRIPTION - MATRIX
For each output it allows to select the input signal to use as the source
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) OUTPUT CHANNELSIdentification of the output channel to set
b) IDENTIFICATIONS OF THE INPUTSIt selects the type of signal to match each output as needed It is possible to select
In A Associated with the input signal ldquoArdquo
In B Associated with the input signal ldquoBrdquo
In A+B Associated with the algebraic sum of the two input signals ldquoArdquo and ldquoBrdquo
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
MENU DESCRIPTION - OPTION
Allows to display the system settings such as the allocation of the inputs and outputs attenuation display contrast and firmware version
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcThis option allows to set the type of input audio signal
An In = Analog audio signals (inputs A and B)
DigIn = Digital audio signals (AESEBU input)
DigOut SrcThis option allows to select the audio source that will be forwarded to the connector AESEBU OUT (digital output)
An In = Audio signals available at analog inputs
Dig In = Audio signals available at digital inputs
OUT 1-2 = Audio signals available on outputs 1 and 2
OUT 3-4 = Audio signals available on outputs 3 and 4
OUT 5-6 = Audio signals available on outputs 5 and 6
Input ModeIt allows to configure the inputs
Indip = They are independent not subject to constraints of any kind between them
Linked = They are connected and work in stereo mode Compressors filters delays volume are identical for the two channels
Atten PadIt shows how to set the -6 dB switch located on the rear side [Ref 5] It is necessary to activate this selector when the analog input levels are too high The selector can be activated only by means of the button the menu is for display only
0 dB = Selector not activated The input signals are the same as the input source
-6 dB = Selector activated The input signals are attenuated by -6 dB with reference to the inner
processor
ContrastAllows to adjust the LCD display contrast to compensate for the brightness difference at the installation sites Greater display brightness allows to navigate correctly and quickly within the menuThe manufacturer output setting is 60
10 More bright 60 More dark 100
Fw VersIt shows the processor firmware version
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
28
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
27
TECHINICAL SPECIFICATION
AUDIO PERFORMANCEFrequency Response +- 01dB (20 to 30kHz)Dynamic Range 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistortion 0002 (1kHz +4dBu)
DIGITAL AUDIO PERFORMANCE Processor DSP 2856-bit Data processing Frequency 24-bit BURR BROWNAnalog converters 24-bit BURR BROWNPropagation Delay 15msStoring configurations 32 preset
CONTROLS Display LCD graficoButtonsControls ESC - MENU - FUNCTIONS SELECTION
ENTERINPUTSOUTPUTSAnalog Input ndeg2 x XLR (3 pole female)
Input impedance gt10KOhmMaximum Level +21dBu senza PAD
+27dBu con PADAnalog Output ndeg6 x XLR (3 pole male)
Output impedance 50OhmMaximum Level +21dBu Type Balanced
Digital Input ndeg1x XLR (3 pole female)Type SPDIF-AESEBU (AES3)
Digital Output ndeg1x XLR (3 pole male)Type Compliant with the input standard
RDnet InputsOutput ndeg2 x XLR RJ45 (CAT 5 cable)USB Tipo B
SOUND CONTROL PARAMETERSGain -80dB a +20dB step 01dBDelay
Input 0 a 729mS step 01 mSOutput 0 a 340mS step 01mSPhase Rotation 0deg - 180deg
COMPRESSIONThreshold -80dB a +20dB step 01dBRatio 11 a Inf1 step 001Output gain 0dB a 40dB step 01dBAttack time 1mS a 1000mS step 01mSRelease time 1mS a 1000mS step 01mSHold time 1mS a 1000mS step 01mS
EQUALIZERS12 equalizers for each input and outputType PEQ (parametrico) Hi-shelf Lo-sheft
Frequency 20Hz a 20KHz step 1HzGain -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (only with PEQ)
CROSSOVER FILTERSFilter Linkwitz Riley
Type HP High-pass LP Low-pass
Slope 12dBoct - 24dBoct - 48dBoctCUT-OFF FREQUENCY 5Hz a 20KHz passo 1Hz
POWER SUPPLY Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)
1719x17x51 inch (WxHxD)WEIGHT 19Kg
(42 lbs)Note Specifications subject to change without notice
EMI CLASSIFICATIONAccording to the standards EN 55103 this equipment is designed and suitable to operate in E3 (or lower E2 E1) Electromagnetic environments
EINLEITUNG
Verpackungsinhalt
Eigenschaften
AC26N ist ein digitaler Audio-Prozessor fuumlr die Verwaltung von Audio-Systemen der fuumlr feste und mobile Installationen entwickelt wurde AC26N benutzt die modernste Technologie mit 2856 bit-Prozessoren und 24-bit-ADDA-Wandlern mit hoher Leistungsfaumlhigkeit Die verfuumlgbaren Funktionen des Prozessors sind Ein- und Ausgangsstufen Verzoumlgerung (delay) Polaritaumlt 12 Equalizer-Frequenzen fuumlr Ein- und Ausgangskanal viele Crossover-Wahlmoumlglichkeiten und Limiter mit hoher Leistung Die Filter-Kontrolle hat eine Aufloumlsung von 1 Hz Die Ein- und Ausgaumlnge koumlnnen mit unterschiedlichen Einstellungen geregelt werden um allen Anforderungen gerecht zu werden AC26N kann in Echtzeit kontrolliert werden und jeder Parameter kann am Frontpaneel und vom Computer mit intuitiver graphischer Schnittstelle mittels Software DVA Network zugaumlnglich und einer Netzverbindung RDnet oder uumlber USB eingestellt werdenDie SW-Aktualisierung fuumlr CPU und DSP uumlber PC erlaubt die Vorrichtung auf dem aktuellen Stand zu halten Man kann 32 vorgesehene Konfigurationen speichern und aufrufen
- AC26N - Bedienungsanleitung- Software-CD- Versorgungskabel
- 2 Ein- und 6 Ausgaumlnge mit flexibler Adressierung- Adressierbarer Stereo-Ein- und Ausgang AESEBU - DSP 2856-bit- AD-Wandler BURR BROWN 24-bit mit hoher Leistungsfaumlhigkeit- Aufloumlsungsfrequenz der Filter 1 Hz - 12 parametrische Equalizer fuumlr jeden Ein- und Ausgang- 2 Crossover-Filter fuumlr jeden Ausgang mit auswaumlhlbarer Neigung 122448dBoct- DRC Multikonfiguration mit hoher Leistungsfaumlhigkeit fuumlr die Konfiguration des
Limitersder Kompression jedes Ein- und Ausgangs- Einstellbare dB-Stufe Polaritaumlt und Verzoumlgerung (delay) fuumlr jeden Ein- und Ausgang- Firmware-Aktualisierung uumlber PC- Graphisches LCD-Display- 32 Voreinstellungen vom Benutzer einstellbar- USB-Schnittstelle fuumlr die Kontrolle und Konfiguration mit dem Computer- Schnittstelle RDnet welche erlaubt bis zu 256 fern liegende Vorrichtungen
zu kontrollieren
PC
PC
RDNET control(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FUNKTIONEN VORDERSEITE
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
BEDIENUNGEN UND FUNKTIONEN
1) DISPLAYDas graphische LCD-Display erlaubt die Informationen des AC26N ohne einen Computer zu benutzen anzuzeigen und zu editieren Der Kontrast kann im Hauptmenuuml eingestellt werden
2) DREHGRIFF Functions Selector UND Push EnterDiese Kontrolle erlaubt sich in den Menuumls auf dem Display zu bewegen und die Parameter auszuwaumlhlen und zu veraumlndernDrehung des Drehgriffes (Functions Selectors)- Man kann sich innerhalb der verschiedenen Menuumlseiten bewegen- Erlaubt die Veraumlnderung der ausgewaumlhlten ParameterDruck des Drehgriffes (Push Enter)- Erlaubt die AuswahlBestaumltigung der Parameter
3) Taste ldquoESCrdquo Diese Kontrolle erlaubt die angezeigten Menuumls zu verlassen oder zur vorherigen Anzeige zuruumlckzukehren
4) Taste ldquoMenuumlrdquo Diese Kontrolle erlaubt den direkten Zugang zum Hauptmenuuml
Deuts
chD
euts
chB
ed
ien
un
gsan
leit
un
gB
ed
ien
un
gsan
leit
un
g
29
Deuts
chD
euts
chB
ed
ien
un
gsan
leit
un
gB
ed
ien
un
gsan
leit
un
g
30
DVA USB Manager
Die Firmware des Verstaumlrkermoduls kann uumlber den USB-Anschluss aktualisiert werdenUm diesen Vorgang zu ermoumlglichen und zu vereinfachen wurde ein dediziertes Programm entwickelt das beim Hersteller angefordert und auf einen Computer installiert werden muss
Wir empfehlen die Software DVA USB Manager direkt von der Webseite dB Technologies (wwwdbtechnologiescom) im Abschnitt laquoSoftware amp Controllerraquo herunterzuladen
DVA Network
AC26N ist mit einer eigenen als RDNET bezeichneten Netzschnittstelle ausgestattet dank der es uumlber ein Interface (RDNET Control) an einen Computer angeschlossen werden koumlnnenHierzu wurde ein Kommunikationsprotokoll entwickelt mit dem die Daten empfangen und gesendet werden Dank dieser Verbindung koumlnnen die Lautsprecherparameter wie Ausgangsleistung Verstaumlrkertemperatur Limiterstatus usw in Echtzeit kontrolliert werden Auszligerdem koumlnnen verschiedene Entzerrungen ausgewaumlhlt bzw neue erstellt werden oder die gewuumlnschte Lautstaumlrke eingestellt werden
Wir empfehlen die Software DVA_Network direkt von der Webseite dB Technologies (wwwdbtechnologiescom) im Abschnitt laquoSoftware amp Controllerraquo herunterzuladenDOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
RUumlCKWANDANSCHLUumlSSE
1586 75 141210 11 13 169 17
14) USB-SteckverbinderDieser USB-Steckverbinder (Typ B) erlaubt den Prozessor an einem Computer anzuschlieszligen um die Firmware mit dem speziellen Programm (DVA Network) zu kontrollieren und zu aktualisieren
15) STROMANSCHLUSS MAINSErlaubt den Anschluss des mitgelieferten Versorgungskabels
16) SICHERUNGSTRAumlGER FUSEAufnahme fuumlr die Netz-Sicherung
17) HAUPTSCHALTER POWERDer Schalter erlaubt das Aus- und Einschalten des Audio-Controllers
BEDIENUNGEN UND FUNKTIONEN
5) WAHLSCHALTER -6dBDer Wahlschalter erlaubt das Level des analogen Eingangs XLR [6] um 6 dB zu verringern und gleichzeitig das hohe Ausgangslevel der Mixer oder anderer Audio-Vorrichtungen auszugleichen Wenn der Balken des Signallevels der Eingaumlnge auf dem Display [1] immer auf Maximum steht zeigt dies an dass das Signallevel am Eingang hoch ist und es wird empfohlen die Daumlmpfung -6dB zu benutzenIm Menuuml Option ist es moumlglich zu kontrollieren ob der Wahlschalter aktiviert ist
6) STECKVERBINDER AM EINGANG A UND BAuf Leitungslinie ausgeglichene EingaumlngeSie koumlnnen auch XLR-Steckdosen aufnehmen
7) AUSGANG-STECKVERBINDER ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo UND ldquo6rdquoAuf Leitungslinie ausgeglichene Ausgaumlnge Sie koumlnnen auch XLR-Stecker aufnehmen
Darauf achten dass die Ausgaumlnge korrekt entsprechend der Einstellungen der einzelnen Kanaumlle an den Lautsprechern oder Verstaumlrkern angeschlossen sind um Schaumlden und Fehlfunktionen vorzubeugen
Abschnitt ldquoAESEBUrdquo
8) EINGANGS-STECKVERBINDER INZusaumltzlich zu den analogen Audio-Eingaumlngen wurde ein digitaler Audio-Eingang SPDIF-AESEBU (AES3) vorgesehen der uumlber das Setup-Menuuml ausgewaumlhlt werden kannDer Eingang erfordert einen ausgeglichenen Anschluss mit einem XLR-Steckverbinder mit einem verdrillten Kabel mit 3 Leitern von 110 Ohm
9) AUSGANGS-STECKVERBINDER OUTDieser Steckverbinder erlaubt das Audiosignal an den analogen oder digitalen Eingaumlngen oder Ausgaumlngen zu verteilen Die Quelle muss uumlber das Menuuml Option eingestellt werdenDer Anschluss muss demselben Standard des Eingang entsprechen [Ref 8]
Abschnitt ldquoRDNETrdquo
10) EINGANGS-STECKVERBINDER DATA INPUTSteckverbinder RJ45 fuumlr den Dateneingang
11) AUSGANGS-STECKVERBINDER DATA LINKSteckverbinder RJ45 fuumlr den Datenausgang Fuumlr die serielle Kaskaden-Verbindung
12) LEUCHTANZEIGE ONDiese gruumlne Anzeige leuchtet nur wenn AC26N uumlber den Computer mit der Haupteinheit RDNET verbunden ist und diese erkannt hat
13) LEUCHTANZEIGE ACTIVEDiese gelbe Anzeige blinkt wenn eine Datenuumlbertragung zwischen RDNET und der Vorrichtung aktiv ist
PUSH
P SHU
SHPU
P SHU
PUSH
ANSCHLUumlSSE
Analoge Audio-AnschluumlsseDie ausgeglichenen Anschluumlsse erlauben die Geraumlusche der Kabel auf ein Minimum zu verringern und so die Benutzung langer Kabel zuzulassenDiese Anschluumlsse koumlnnen sowohl an den Ein- als auch an den Ausgaumlngen benutzt werdenDer XLR-Steckverbinder muss mit Pin 1 an Masse Pin 2 am Pluspol (+) und Pin 3 am Minuspol (-) angeschlossen werden Bei einem abgeschirmten Kabel muss die Abschirmung an Pin 1 liegenDie Verbindungskabel XLR-XLR und XLR-Jack 14 (63 mm) koumlnnen fuumlr den Anschluss
12
3
Eingang
XLR weiblichen
Pin 3 = MinuspolErkaumlltungphase -VE
Pin 3 = MinuspolErkaumlltungphase -VE
1 2
3
Ausgang
XLR maumlnnlichen
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Ring
Schaft
Spitze = PluspolWaumlrmephase +VE
Ring = MinuspolErkaumlltungphase -VE
Schaft=SchirmMasse
Spitze
Die nicht ausgeglichenen Anschluumlsse koumlnnen auch benutzt werden wenn die Kabelgeraumlusche ansteigen und diese Kabel duumlrfen nicht laumlnger sein als 5 MeterDiese Anschluumlsse koumlnnen sowohl an den Ein- als auch an den Ausgaumlngen benutzt werdenDie nicht ausgeglichenen Anschluumlsse koumlnnen das Signallevel am Eingang um 6 dB verringern um dem vorzubeugen muss Pin 3 an Masse angeschlossen werden obwohl dies das Geraumlusch verstaumlrken kann
12
3
Eingang
XLR weiblichen
1 2
3
Ausgang
XLR maumlnnlichen
Spitze Schaft
Spitze = Signal
Schaft=SchirmMasse
Pin 3 = zu Pin 1 gebruumlckt
Pin 3 = zu Pin 1 gebruumlckt
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
31
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
32
Digitales Audio (AESEBU)AESEBU (Protokoll AES3) ist ein ausgeglichener und uumlber einen Transformator elektrisch isolierter Eingang Er erlaubt die Benutzung von zwei Kanaumllen an einem einzigen abgeschirmten bipolaren Kabel Das gedrillte Kabel muss 3-polig sein eine Impedanz von 100 Ohm haben und mit einem XLR-Steckverbinder (AES3 Standard) abgeschirmt sein
RdnetJeder Port RDNet an Control 2 und Control 8 kann an max 32 kompatiblen Vorrichtungen die in Kaskade geschaltet sind angeschlossen werden Im nachstehenden Beispiel ist der Port der Kontrolleinheit RDNET CONTROL 2 am Eingang DATA INPUT eines AC 26N angeschlossen dessen paralleler Ausgang DATA LINK zum Eingang des naumlchsten AC26N geht Im Beispiel ist [n] eine Nummer zwischen 3 und 32 (maximale Anzahl der anschlieszligbaren Vorrichtungen an nur einem Netz)
RJ 45
|1|2|3|4|5|6|7|8|
Die Gesamtlaumlnge des Kabels CAT5 eines Unternetzes kann NICHT laumlnger als 900 Meter sein
Der Steckverbinder muss wie folgt angeschlossen sein1 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio +) 2 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio -)3 ndash Verfuumlgbar fuumlr andere Funktionen (zB analoge Masse)4 ndash digitale Masse5 ndash digitale Masse6 ndash Verfuumlgbar fuumlr andere Funktionen (zB Versorgung)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
EINSCHALTEN
Beim Einschalten der Vorrichtung startet die Initialisierung die einige Sekunden lang dauert Auf dem Display wird das Modell das Logo und der Fortschrittsbalken der Ladung des Programms angezeigt
Nach der Initialisierung erscheint auf dem Display das Menuumlfenster Meters Um die Angaben im Detail zu erfahren beziehen Sie sich bitte auf das Kapitel BESCHREIBUNG DES MENUumlFENSTERS Meters
AC26N kann jetzt benutzt werden
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
MENUrsquo PRINCIPALE
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Die sechs Menuumls im Prozessor zeigen undoder konfigurieren die Systemparameter
Anzeige der Levels der Ein- und Ausgaumlnge Anzeige des benutzten Programms und dessen Status Mute schnell
Speicherung Speicherung und Eliminierung der Systemkonfigurationen
Auswahl der Ausgaumlnge je nach Eingangssignal
Konfiguration jedes einzelnen Kanals
Konfiguration der Schnittfrequenzen und der Filtertypen fuumlr jeden einzelnen Ausgang
Zuordnung der Ein- und Ausgaumlnge Kontrast des Displays Firmware-Version Eingaumlnge und andere Optionen
Das Menuuml und die einzelnen Optionen der Anzeige koumlnnen durch Drehen des Drehgriffes FUNKTIONS SELECTOR ( ) ausgewaumlhlt werden
Die Hauptmenuumls sind
Meters
Preset
Matrix
Ch Job
X-Over
Option
Um die Auswahl zu treffen muss der gewuumlnschte Parameter auswaumlhlt und der Drehgriff Push Enter( | ) gedruumlckt werdenDas selbe Verfahren muss fuumlr die Auswahl undoder die Aumlnderung der Optionen innerhalb der Menuumlpunkte angewendet werden
BESCHREIBUNG DES MENUumlFENSTERS Meters
Diese Seite erlaubt die Konfigurationen und den allgemeinen Status der Ein- und Ausgaumlnge der benutzten Programmversion dessen Status und die Steuerung des Systems anzuzeigen
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
KONFIGURATION UND ANZEIGE
Um in das Fenster des Hauptmenuumls zu gelangen muss die Taste Menuuml ( ) auf der Frontseite der Vorrichtung gedruumlckt werdenMit der Taste ESC ( ) kehrt man von jeder Seite des Menuumls auf die vorherige Seite zuruumlck
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
33
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
34
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziertBei den digitalen Eingangssignalen entspricht die Angabe A und B dem EingangDreht man den Drehgriff FUNCTIONS SELECTOR [2] durchlaumluft man zyklisch die Ein- und Ausgangskanaumlle und die Angabe Mute allgemein (d) der ausgewaumlhlte Kanal wird hervorgehoben
b) BALKEN FUumlR DAS KOMPRESIONSLEVELMUTE KANAL
SIGNALKOMPRESSIONDie Signalkompression wird durch das Gleiten des rechten Balkens von oben nach unten angezeigt
MUTE Jeder einzelne Kanal kann auf Mute gestellt werden Den Kanal auswaumlhlen und den Drehgriff Push Enter [2] druumlcken um die Aumlnderung des Status zu bestaumltigen Die Angabe des Kanals wird durch den Buchstaben M ersetzt und der Balken wird komplett hervorgehobenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werden
c) BALKEN DES SIGNALLEVELSDie Anzeige des Levels jedes einzelnen Kanals wird durch das Gleiten des linken Balkens angezeigt
d) MUTE ALLGEMEINEs ist moumlglich alle Ein- und Ausgaumlnge gleichzeitig auf Mute zu schalten Den Drehgriff FUNCTIONS SELECTOR drehen den Buchstaben M waumlhlen und dann den Drehgriff Push Enter druumlckenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werdenDie allgemeine Stummschaltung hat eine houmlhere Prioritaumlt als die Stummschaltung der einzelnen Kanaumlle
e) ANSTEUERUNGSARTENEs wird angezeigt wie AC26N benutzt wird undoder an welchen Vorrichtungen es angeschlossen ist
= Benutzung stand-alone Kein Anschluss an einer externen Vorrichtung
= Direkt am Netz RDnet und am Computer angeschlossen
= Uumlber USB-Kabel direkt am Computer angeschlossen
f) ANZEIGE DES STATUS DER EINSTELLUNGENHier wird angezeigt ob einer oder mehrere Parameter des geladenen Programms im Vergleich zur letzten Speicherung veraumlndert wurden
Original-Programm
Programm mit veraumlnderten Parametern
g) EINGESTELLTES PROGRAMMDie Nummer zeigt das vom System geladene und benutzte Programm in Bezug auf die Lokalisierung der Speicherung an Fuumlr weitere Details beziehen Sie sich bitte auf das Menuuml Preset
Local
NET
USB
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
BESCHREIBUNG DES MENUumlFENSTERS Ch Job
Dieses Fenster erlaubt die Anzeige der Konfiguration jedes einzelnen Kanals
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) SIGNALLEVELZeigt die Signalstaumlrke an Das Ansteigen der Signalintensitaumlt wird in Dezibel (dB) ausgedruumlckt Der Parameter kann zwischen -8000 dB und +2000 dB in Schritten von 001 dB ausgewaumlhlt werden Ein Anstieg von 6 dB ist fast gleich eine Verdoppelung in linearer Skala des Spannungswertes des SignalsBei einer Staumlrke von 0 dB wird das Signal verstaumlrkt waumlhrend es ein einer Staumlrke von weniger als 0 dB abgeschwaumlcht wird
c) VERZOumlGERUNG DES SIGNALS (DELAY)Das wiedergegebene Audio-Signal kann verzoumlgert werden um die akustische Ausrichtung zu erlauben Dies gleicht die verschiedenen Positionen der Lautsprecher bei der Installation und Klangwiedergabe aus und wird in mS ausgedruumlckt Der Parameter kann zwischen 00 mS und 729 mS in Schritten von 01mS ausgewaumlhlt werden
Um ein Audiosignal auszurichten kann folgende Formel benutzt werden
Verzoumlgerung = GAPx1000)344
Verzoumlgerung = mS (in Millisekunden ausgedruumlckt)GAP = Abstand des Lautsprechers vom Referenzpunkt (in Metern ausgedruumlckt)Klanggeschwindigkeit = 344 ms
d) MUTEJeder einzelne Kanal kann auf Mute gestellt werden Derselbe Befehl kann im Fenster des Menuumls Meters aktiviert werden PS Die al lgemeine Stummschaltung hat eine houmlhere Priori taumlt als die Stummschaltung der einzelnen Kanaumlle
e) PHASEErlaubt die Phasenrotation um 180deg zum EingangssignalDiese Rotation erlaubt vor Allem die Optimierung der niederen Frequenzen bei komplexen Installationen
f) ENTZERRUNGENDieser Befehl oumlffnet das Menuumlfenster fuumlr die Entzerrung des einzelnen Kanals Er wird vor Allem benutzt um eine oder mehrere Frequenzen zu korrigieren die gedaumlmpft oder verstaumlrkt werden muumlssen
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
35
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
36
AC26N verwaltet 12 Filter fuumlr jeden einzelnen Ein- und Ausgangskanal mit drei verschiedenen Konfigurationen- Equalizer PEQ (peaking equalizer) ist ideal um nur ein bestimmtes Frequenzband
zu identifizieren zu isolieren und zu korrigieren Es gehen alle Frequenzen durch aber nur die um die mittlere Frequenz steigt und sinkt um eine bestimmte Bandbreite und eine bestimmte Staumlrke
- Equalizer High-Shelf geht alle Frequenzen durch aber die Frequenzen uumlber der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
- Equalizer Low-Shelf geht alle Frequenzen durch aber die Frequenzen unter der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
f Nummerierung der 12 verfuumlgbaren Filter fuumlr diesen Ein- oder Ausgang1
f2 Es wird der Filtertyp angezeigt
Dis Ausgeschaltet (nicht vorhanden)
PEQ Peaking equalizer
Sh H Filter High-Shelf
Sh L Filter Low-shelf
Beispiele PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
ANMERKUNGDer Parameter Bw legt das Frequenzfeld neben der eingestellten Frequenz fest wo der Filter aktiviert wird je houmlher der Bw-Wert desto houmlher das Frequenzfeld (1Bw=1 Oktave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filter High-Shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filter Low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) KOMPRESSIONDieser Befehl oumlffnet das Menuumlfenster fuumlr die Kompression des einzelnen Kanals
g1) TresholdIdentifiziert die Schwelle an der das Kompressionsverhaumlltnis beginnt Der Basiswert 11
g2) RatioIdentifiziert das Kompressionsverhaumlltnis zwischen dem Ein- und Ausgangssignal
g3) Post Gain Attach Release HoldDiese Daten entsprechen dem Kompressionsverhaumlltnis das man erreichen moumlchte
Post Gain ist der Gewinn am AusgangAttack ist die Anschlusszeit Release ist die ReleasezeitHold ist die Beibehaltungszeit
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
BESCHREIBUNG DES MENUumlFENSTERS Preset
Dieses Fenster erlaubt bis zu 32 Konfigurationen im AC26N zu speichernDer Hersteller liefert das System mit einem voreingestellten Programm das auf Position 0 gespeichert ist und nicht uumlberschrieben werden kann
032 Es zeigt die Lokalisierung der Speicherung der KonfigurationDiese Nummer erscheint auch im Fenster Meters auf der Position (g) Das benutzte Programm kann jederzeit vom Benutzer angezeigt werden
Empty Preset Es ist der Name der der Nummer der Lokalisierung zugeordnet wird wenn keine Einstellung gespeichert ist (leer)
Local preset Es i s t de r Name de r de r Nummer de r Loka l i s i e rung zugeordnet wird wenn eine Konfiguration gespeichert wird
ANMERKUNG = Man kann eine Einstellung mit dem gewuumlnschten Namen mit max 16 Buchstaben nur speichern wenn man die Schnittstelle uumlber den Computer benutzt
Bei der Wahl eines Programms erscheint folgendes Fenster
Anzeige des Namens der dem Programm zugeordnet istUm auf die Anwendung einzuwirken stehen 3 Auswahlmoumlglichkeiten zur Verfuumlgung
Das Programm wird im Speicher des AC 26N gespeichert
Das Programm wird geloumlscht
Das Programm wird geladen und ist bereit fuumlr die Benutzung
Save
Del
Load
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
37
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
38
BESCHREIBUNG DES MENUumlFENSTERS X-Over
Dieses Fenster erlaubt fuumlr jeden Ausgang einen Bassdurchgangsfilter einen Hochdurchgangsfilter oder mittels Kombination von beiden einen Banduumlbergangsfilter zu waumlhlenDer Filter ist ein Linkwitz-Riley wo man die Neigung von 12 dBoct 24dBoct oder 48 dBoct und die entsprechende Schnittfrequenz auswaumlhlen kann
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) AUSGANGSKANAumlLE
Die Steckverbinder am Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) FILTER CROSSOVERDen Filter nach Bedarf waumlhlen Man kann folgendes auswaumlhlen
Dis Kein Filter aktiviert
HP Hochdurchgangsfilter nur den Teil des Audiosignals durchlassen der uumlber der Schnittfrequenz liegt
LP Bassdurchgangsfilter nur den Teil des Audiosignals durchlassen der unter der Schnittfrequenz liegt
Filter-Konfiguration Tiefpass Hochpass
Nichts Dis Dis
Hochpass HP Dis
Tiefpass Dis LP
Bandpass HP LP
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
c) DAumlMPFUNGSNEIGUNGDie Daumlmpfungsneigung des Audiosignals auf der Basis der Verringerung auswaumlhlen die man erreichen moumlchte Je houmlher die Daumlmpfungsneigung bei gleicher Schnittfrequenz desto groumlszliger ist die Signalauswahl Man kann folgendes waumlhlen
12 entsprechend 12 dboct
24 entsprechend 24 dboct
48 entsprechend 48 dboct
d) SCHNITTFREQUENZErlaubt die Durchgangsfrequenz der niederen Frequenzen (Bassdurchgangsfilter) oder der hohen Frequenzen (Hochdruchgangsfilter) einzustellenDie Auswahl des Schnitts bezieht sich auf die Wiedergabe die man erreichen moumlchteDie benutzte Maszligeinheit ist Hz
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
BESCHREIBUNG DES MENUumlFENSTERS Matrix
Erlaubt fuumlr jeden Ausgang das Eingangssignal zu waumlhlen das als Quelle benutzt werden soll
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) AUSGANGSKANAumlLEIdentifizierung des einzustellenden Ausgangskanals
b) IDENTIFIZIERUNG DER EINGAumlNGEDen Signaltyp auswaumlhlen der nach eigener Anforderung jedem einzelnen Ausgang zugeordnet werden soll Man kann folgendes waumlhlen
In A Das Signal wird dem Eingang A zugeordnet
In B Das Signal wird dem Eingang B zugeordnet
In A+B Zuordnung der a lgebra ischen Summe der be iden Eingangssignale A und B
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
BESCHREIBUNG DES MENUumlFENSTERS Option
Erlaubt die Anzeige der Systemeinstellungen wie die Zuordnung der Ein- und Ausgaumlnge Daumlmpfung Displaykontrast und Firmware-Version
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B Src
Diese Option erlaubt die Einstellung des Audio-Signaltyps am Eingang
Analoge Audiosignale (Eingaumlnge A und B)
Digitale Audiosignale (Eingang AESEBU)
DigOut Src
An In =Audiosignale an den analogen Eingaumlngen
Dig In =Audiosignale am digitalen Eingang
OUT 1-2 =Audiosignale an den Ausgaumlngen 1 und 2
OUT 3-4 =Audiosignale an den Ausgaumlngen 3 und 4
OUT 5-6 =Audiosignale an den Ausgaumlngen 5 und 6
Input Mode
An In
Dig In
Indip =
Linked =
Diese Option erlaubt die Audioquelle zu waumlhlen die fuumlr den Steckverbinder AESEBU OUT (digitaler Ausgang) bestimmt ist
Erlaubt die Eingaumlnge zu konfigurieren
Sie sind unabhaumlngig und selbststaumlndig sie unterliegen keinen Verpflichtungen untereinander Sie sind verbunden und funktionieren im Stereo-Modus
Die Kompressoren Filter Verzoumlgerungen die Lautstaumlrke sind bei beiden Kanaumllen identisch
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
39
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
40
Atten PadZeigt an wie der Wahlschalter -6 dB auf der Ruumlckseite eingestellt ist [Ref 5] Dieser Wahlschalter muss aktiviert werden wenn das Level an den analogen Eingaumlngen zu hoch ist Der Wahlschalter wird uumlber die Taste aktiviert im Menuuml gibt es nur eine Anzeige
0dB = Wahlschalter nicht aktiviert
-6dB = Wahlschalter aktiviert
Contrast
10 heller 60 dunkler 100
Fw Vers
Die Eingangssignale sind dieselben wie die Eingangsquelle
Die Eingangssignale werden vom internen Prozessor um -6 dB gedaumlmpft
Erlaubt den Kontrast des LCD-Displays einzustellen um den Unterschied der Helligkeit auf den Installationsort auszurichten Ein deutlicheres Display erlaubt auf korrekte und schnelle Weise innerhalb der Menuumls zu surfenDie Hersteller-Einstellung am Ausgang liegt bei 60
Zeigt die Firmware-Version des Prozessors an
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
41
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
42
TECHNISCHE DATEN
Antwort in FrequenzDynamische GammaCMMRCrosstalkDistorsion
ProzessorFrequenz der DatenausarbeitungAnaloge Converter Verzoumlgerung der VerteilungSpeicherung der Konfigurationen
DisplayTastenBedienungen
Analoger Eingang ndeg2 x XLR (3-poliger Female Stecker)Impedanz des Eingangs gt10KOhmMaximales Level +21dBu ohne PAD
+27dBu bei PAD
Impedanz des Ausgangs 50OhmMaximales Level +21dBu Typ symmetrisch
Typ SPDIF-AESEBU (AES3)
Typ Entsprechend dem Standard des Eingang
Typ
Typ
NETZSPANNUNGABMESSUNGEN (BXHXT)GEWICHT
AUDIO-LEISTUNGEN+- 01dB (20 to 30kHz)116dB typgt 60dB (50 to 10kHz)lt -100dB0002 (1kHz +4dBu)
DIGITALE AUDIO-LEISTUNGEN DSP 2856-bit 48KHz24-bit BURR BROWN15ms32 preset
KONTROLLEN LCD GrafikESC - MENU - FUNCTIONS SELECTIONENTER
EIN-AUSGAumlNGE
Analoger Ausgang ndeg6 x XLR (3-poliger Male Stecker)
Digitaler Eingang ndeg1x XLR (3-poliger female Stecker)
Digitaler Ausgang ndeg1x XLR (3-poliger Male Stecker)
Ein-Ausgang Rdnet ndeg2 x XLR RJ45 (kabel CAT 5) USB Typ B
KONTROLLPARAMETER AUDIOStaumlrke -80dB a +20dB step 01dBVerzoumlgerung Eingang 0 a 729mS step 01 mS
Ausgang 0 a 340mS step 01mSPhasenrotation 0deg - 180deg
KOMPRESSIONSchwelle -80dB a +20dB step 01dBVerhaumlltnis 11 a Inf1 step 001Staumlrke am Ausgang 0dB a 40dB step 01dBAnschlusszeit 1mS a 1000mS step 01mSReleasezeit 1mS a 1000mS step 01mSBeibehaltungszeit 1mS a 1000mS step 01mS
EQUALIZER12 Equalizer fuumlr jeden Ein- und Ausgang
PEQ (parametrischer) Hi-shelf Lo-sheftFrequenz 20Hz a 20KHz step 1HzStaumlrke -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (lediglich PEQ)
FILTER CROSSOVERFilter Linkwitz Riley
HP HochdurchgangsfilterLP Bassdurchgangsfilter
Neigung 12dBoct - 24dBoct - 48dBoctSchnittfrequenz 5Hz a 20KHz step 1Hz
Full-range 100-240Vac 50-60Hz430482x43x130mm 19Kg
AnmerkungenSpezifikationen unterliegen Aumlnderungen ohne Vorankuumlndigung
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
INTRODUCTIONAC26N est un processeur audio numeacuterique pour la gestion de leacutequipement audio conccedilu pour des installations fixes et mobiles Il fonctionne selon une technologie de pointe avec des processeurs agrave 2856bits et des convertisseurs ADDA agrave 24-bits hautes performances Les fonctions du processeur sont les niveaux dentreacutee et de sortie le deacutelai (delay) la polariteacute 12 bandes deacutegalisation par canal dentreacutee et de sortie diffeacuterentes seacutelections de croisement (crossover) et un limiteur hautes performances Le controcircle des filtres a une reacutesolution de 1Hz Les entreacutees et les sorties peuvent ecirctre programmeacutees en plusieurs configurations pour satisfaire tous les besoins AC26N peut ecirctre controcircleacute en temps reacuteel et tous les paramegravetres peuvent ecirctre configureacutes depuis le pupitre frontale et par ordinateur avec interface graphique intuitive accessible via le logiciel laquoDVA Networkraquo et une connexion de reacuteseau deacutedieacutee RDnet ou USBLa mise agrave jour du logiciel pour lUniteacute centrale et DSP par ordinateur portable permet de maintenir le dispositif actualiseacute Il est possible denregistrer et de rappeler 32 configurations preacute-eacutequipeacutees de configuration
Contenu de lemballage - AC26N - Mode demploi- CD logiciel- Cacircble dalimentation
Caracteacuteristiques- 2 entreacutees et 6 sorties avec adressage flexible- Entreacutee et sortie steacutereacuteo AESEBU adressables - DSP 2856-bit- Convertisseurs AD BURR BWOWN 24-bit hautes performances- Freacutequence de reacutesolution des filtres 1 Hz - 12 eacutegaliseurs parameacutetriques pour chaque entreacutee et sortie- 2 filtres de croisement par sortie avec pente seacutelectionnable agrave 122448dBoct- DRC agrave configuration multiple hautes performances pour configuration limiteur
compression pour chaque entreacutee et sortie- Niveau reacuteglable en dB polariteacute et deacutelai pour chaque entreacutee et sortie- Mise agrave jour du micrologiciel par lordinateur- Affichage graphique agrave cristaux liquides- 32 preacutereacuteglages enregistrables par lutilisateur- Interface USB pour le controcircle et la configuration par ordinateur- Interface RDnet permettant de controcircler jusquagrave 256 dispositifs agrave distance
PC
PC
RDNETcontrol(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FONCTIONS DE LA FACE AVANT
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
COMMANDES ET FONCTIONS1) AFFICHAGE
Laffichage graphique agrave cristaux liquides permet de visualiser et deacutediter les informations de lAC26N sans utiliser lordinateur Le contraste peut ecirctre configureacute dans le menu principal
2) MANETTE Functions Selector et Push EnterCe controcircle permet de se deacuteplacer de seacutelectionner et de modifier les paramegravetres dans les menus affichables agrave leacutecranRotation de la manette (Functions Selectors)- permet de se deacuteplacer sur les diffeacuterentes pages du menu - permet de modifier les paramegravetres seacutelectionneacutesPression de la manette (Push Enter)- permet de seacutelectionnervalider les paramegravetres
3) Bouton ESC Ce controcircle permet de quitter les menus afficheacutes ou de revenir agrave la visualisation preacuteceacutedente
4) Bouton Menu Ce controcircle permet dacceacuteder directement au menu principal
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
Fra
nccedilais
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
43
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
Fra
nccedilais
44
DVA Network
AC26N est eacutequipeacute dune interface de reacuteseau proprieacutetaire deacutenommeacutee RDNET au moyen de laquelle il est possible de sinterfacer agrave lordinateur agrave travers un peacuteripheacuterique (RDNET control)
Pour cela un protocole de communication a eacuteteacute deacuteveloppeacute avec lequel il est possible de recevoir et denvoyer les donneacutees ce branchement permet de faire le monitorage en temps reacuteel des paramegravetres du diffuseur comme puissance de sortie tempeacuterature de lamplificateur eacutetat du limiteur etc Il est aussi possible de seacutelectionner diffeacuterentes eacutegalisations ou den creacuteer de nouvelles et de reacutegler les niveaux de volume souhaiteacutes au moyen dun plug-in approprieacute
On conseille de teacuteleacutecharger gratuitement le logiciel DVA Network directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
DVA USB Manager
On conseille de teacuteleacutecharger gratuitement le logiciel DVA USB Manager directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
Le micrologiciel du module amplificateur peut ecirctre remis agrave jour par le port USBPour rendre cette mise agrave jour possible et facile un programme speacutecifique a eacuteteacute deacuteveloppeacute
DOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
CONNEXIONS DU PANNEAU ARRIEgraveRE
1586 75 141210 11 13 169 17
14) Connecteur ldquo USBrdquoCe connecteur USB (type B) permet de connecter le processeur agrave un ordinateur pour le controcircle et la mise agrave jour du micrologiciel via un programme deacutedieacute (DVA Network)
15) PRISE DALIMENTATION MAINSPermet la connexion du cacircble dalimentation fourni de seacuterie
16) PORTE-FUSIBLE FUSELogement pour fusible de ligne
17) INTERRUPTEUR GENERAL POWERLinterrupteur permet de mettre en marche ou deacuteteindre le controcircleur audio
COMMANDES ET FONCTIONS
5) SELECTEUR ldquo-6dBrdquoLe seacutelecteur permet de reacuteduire de 6dB les niveaux dentreacutee analogiques XLR [6] tout en compensant les niveaux eacuteleveacutes de sortie des meacutelangeurs ou dautres dispositifs audio Quand la barre du niveau de signal des entreacutees sur laffichage [1] reste au maximum cela indique que le niveau du signal entrant est eacuteleveacute Il est alors conseilleacute dutiliser latteacutenuation -6dBIl est possible de veacuterifier quand le seacutelecteur est activeacute par le menu Option
6) CONNECTEURS DENTREE ldquoArdquo ET ldquoBrdquoEntreacutees eacutequilibreacutees au niveau de la ligneIls sont en mesure daccepter des connecteurs XLR macircles
7) CONNECTEURS DE SORTIE ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo ET ldquo6rdquoSorties eacutequilibreacutees au niveau de la ligne Ils sont en mesure daccepter des connecteurs XLR femelles
Prendre garde agrave brancher convenablement les sorties sur les diffuseurs ou les amplificateurs en fonction des configurations de chaque canal pour eacuteviter des deacutegacircts et des problegravemes de fonctionnement
Section ldquoAESEBUrdquo
8) CONNECTEUR DENTREE INOutre les entreacutees audio analogiques une entreacutee audio numeacuterique SPDIF-AESEBU (AES3) a eacuteteacute preacutevue et peut ecirctre seacutelectionneacutee par le menu de setupLentreacutee requiert une connexion eacutequilibreacutee en utilisant un connecteur XLR avec un cacircble agrave 3 conducteurs de 110ohm torsadeacute
9) CONNECTEUR DE SORTIE OUTCe connecteur permet de relancer le signal audio dans les entreacutees analogiques ou numeacuteriques ou sur les sorties La source doit ecirctre reacutegleacutee par le menu OptionLa connexion sera conforme agrave la mecircme norme que lentreacutee [reacutef8]
Section ldquoRDNETrdquo
10) CONNECTEUR DENTREE DATA INPUTConnecteur RJ45 entreacutee de donneacutees
11) CONNECTEUR DE SORTIE DATA LINKConnecteur RJ45 sortie de donneacutees pour la connexion de seacuterie en cascade
12) VOYANT LUMINEUX ONCe voyant de couleur verte sallume uniquement quand lAC26N a reconnu et est connecteacute agrave luniteacute principale RDNET par lordinateur
13) VOYANT LUMINEUX ACTIVECe voyant de couleur jaune clignote quand une transmission des donneacutees est active entre RDNET et le dispositif
PUSH
P SHU
SHPU
P SHU
PUSH
CONNEXIONS
Audio analogiquesLes connexions eacutequilibreacutees permettent de reacuteduire au minimum le bruit provoqueacute par les cacircbles et dutiliser de longs cacircblesCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLe connecteur XLR doit ecirctre brancheacute avec la broche 1 agrave la masse la broche 2 au chaud (+) et la broche 3 au froid (-) En cas de cacircble blindeacute brancher le blindage agrave la broche 1Les cacircbles de connexion XLR-XLR et XLR-Jack14(63mm) peuvent semployer pour la connexion agrave lAC26N
12
3
Entreacutee
Entreacutee
XLR - femme
XLR - femme
1 2
3
Sortie
Sortie
XLR - Macircle
XLR - Macircle
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2 = Point chaudPhase +VE
Broche 3 =Point froidPhase -VE
Broche 3 =Point froidPhase -VE
Anneau
Manchon
Pointe Point chaudPhase +VE
Anneau = Point froidPhase -VE
ManchonB Masselindeacute
Pointe
Les connexions deacuteseacutequilibreacutees peuvent semployer mecircme si le bruit provoqueacute par les cacircbles augmente Les cacircbles ne peuvent deacutepasser 5m de longCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLes connexions deacuteseacutequilibreacutees peuvent abaisser le niveau du signal entrant de 6dB Pour remeacutedier agrave cet inconveacutenient il faut brancher la broche 3 agrave la masse mecircme si cela augmente le bruit
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
45
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
46
12
3
1 2
3
Pointe Manchon
Pointe = Signal
Broche 3 = Link to Pin 1
Broche 3 = Link to Pin 1
ManchonB Masselindeacute
Audio numeacuteriques (AESEBU)
AESEBU (protocole AES3) est une entreacutee eacutequilibreacutee isoleacutee eacutelectriquement agrave laide dun transformateur Elle permet demployer deux canaux audio dans un seul cacircble bipolaire blindeacute Les caracteacuteristiques du cacircble doivent ecirctre de 3 pocircles impeacutedance 100ohm torsadeacute et blindeacute avec connecteur XLR (AES3 standard)
RJ 45
|1|2|3|4|5|6|7|8|
RDnet
Chaque port RDNet des Control 2 et Control 8 peut ecirctre brancheacute agrave un maximum de 32 dispositifs compatibles placeacutes en cascade Dans lexemple suivant le port de luniteacute de controcircle RDNET CONTROL 2 est relieacute agrave lentreacutee DATA INPUT dun AC26N dont la sortie parallegravele DATA LINK est envoyeacutee agrave lentreacutee de lAC26N successif Dans lexemple [n] est un nombre compris entre 3 et 32 (limite maximale des dispositifs que lon peut relier agrave un sous-reacuteseau)
La longueur totale du cacircble CAT5 dun sous-reacuteseau NE peut PAS deacutepasser 900 megravetres
Le connecteur doit ecirctre relieacute comme 1 ndash disponible pour dautres fonctions (par exemple audio +) 2 ndash disponible pour dautres fonctions (par exemple audio )3 ndash disponible pour dautres fonctions (par exemple masse analogique)4 ndash masse numeacuterique5 ndash masse numeacuterique6 ndash disponible pour dautres fonctions (par exemple alimentation)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
MISE EN MARCHE
Lors de la mise en marche du dispositif linitialisation deacutebute et dure quelques secondes Leacutecran affiche le modegravele le logo et la barre de progression du chargement du programme
En fin de processus dinstallation leacutecran affiche la fenecirctre du menu Meters Pour connaicirctre les indications en deacutetail consulter le paragraphe DESCRIPTION FENETRE MENU Meters
LAC26N est precirct agrave lemploi
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION ET VISUALISATION
Pour entrer dans la fenecirctre du menu principal il faut pousser sur la touche MENU ( ) agrave lavant du dispositifDune page quelconque du menu en poussant sur la touche ESCrdquo ( ) on revient automatiquement sur la page-eacutecran preacuteceacutedente
MENU PRINCIPAL
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Le processeur contient six menus Ils montrent etou configurent les paramegravetres du systegravemeLes menus principaux sont
Meters Visualisation des niveaux des entreacutees et des sorties visualisation du programme utiliseacute et eacutetat mute rapide
Preset Meacutemoriser enregistrer et eacuteliminer les configurations du systegraveme
Matrix seacutelectionner les sorties en fonction du signal entrant
Ch Job configuration de chaque signal
X-Over configurer les freacutequences de coupure et les types de filtres pour chaque sortie
Option attribution des entreacutees et des sorties contraste daffichage la version du micrologiciel les entreacutees et dautres options
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
47
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
48
DESCRIPTION DE LA FENETRE MENU Metersrdquo
Cette fenecirctre permet de visualiser les configurations et leacutetat geacuteneacuteral des entreacutees et des sorties la version du programme utiliseacute son eacutetat et le mode de pilotage du systegraveme
Les menus et les options afficheacutees peuvent se seacutelectionner en tournant la manette ldquoFUNCTIONS SETECTORrdquo ( ) Pour avoir accegraves agrave linteacuterieur de la seacutelection il faut mettre le paramegravetre souhaiteacute en eacutevidence et pousser sur la manette ldquoPush Enterrdquo ( | ) Il faut en faire de mecircme pour seacutelectionner etou modifier les options dans les commandes du menu
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositifAvec des signaux dentreacutee numeacuteriques les indications ldquoArdquo et ldquoBrdquo correspondent agrave lentreacuteeEn tournant la manette ldquoFUNCTIONS SELECTORrdquo [2] on fait deacutefiler en mode cyclique les canaux dentreacutee de sortie et lindication de mute geacuteneacuteral (d) le canal seacutelectionneacute est mis en eacutevidence
b) BARRE DE NIVEAU DE COMPRESSIONMUTE CANAL
COMPRESSION DE SIGNALLa compression du signal est visualiseacutee par le deacutefilement de la barre de droite de haut en bas
MUTE Chaque canal peut ecirctre placeacute en mute Seacutelectionner le canal et pousser sur la manette ldquoPush Enterrdquo [2] pour valider le changement deacutetat Lindication du canal sera remplaceacutee par la lettre M et la barre sera totalement mise en eacutevidencePour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterations
c) BARRE DE NIVEAU DE SIGNALLindication du niveau de chaque canal est signaleacutee par le deacutefilement de la barre de gauche
d) MUTE GENERALIl est possible de mettre simultaneacutement toutes les entreacutees et les sorties en mute Tourner la manette ldquoFUNCTIONS SELECTORrdquo seacutelectionner la lettre M et pousser sur la manette Push EnterPour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterationsLe mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) MODES DE COMMANDEIl affiche le mode dutilisation etou les dispositifs qui sont relieacutes agrave lAC26N
Local = utilisation autonome Aucune connexion agrave un dispositif exteacuterieur
NET = relieacute directement au reacuteseau deacutedieacute RDNet et agrave lordinateur
USB = relieacute directement agrave un ordinateur par cacircble USB
f) INDICATION DETAT DE PARAMETRAGECette indication permet de constater si un ou plusieurs paramegravetre(s) du programme chargeacute aont eacuteteacute modifieacute(s) par rapport au dernier sauvetage
= programme dorigine
= programme avec des paramegravetres modifieacutes
g) PROGRAMME CONFIGURELe chiffre indique le programme chargeacute et utiliseacute par le systegraveme agrave lemplacement de sauvetage Consulter le menu de Preset pour de plus amples deacutetails
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
DESCRIPTION DE LA FENETRE MENU Ch Job
Cette fenecirctre permet dafficher la configuration de chaque canal
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) NIVEAU DU SIGNALIndique le gain du signal Laugmentation de lintensiteacute dun signal est libelleacutee en deacutecibel (dB) Le paramegravetre peut ecirctre seacutelectionneacute de -8000dB agrave +2000dB avec des pas de 001dB Une augmentation de 6dB est eacutegale approximativement au redoublement agrave leacutechelle lineacuteaire du niveau du signal sous tensionAvec un gain supeacuterieur agrave 0dB le signal est amplifieacute tandis quavec un gain infeacuterieur agrave 0dB le signal est atteacutenueacute
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
49
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
50
c) DELAI DU SIGNAL (DELAY)Le signal audio reproduit peut ecirctre retardeacute pour permettre lalignement acoustique Cela compense les diffeacuterentes positions des diffuseurs pendant linstallation et la reproduction sonore Il se libelle en mS Le paramegravetre peut ecirctre seacutelectionneacute de 00mS agrave 729mS avec un pas de 01mSPour aligner un signal audio il est possible dutiliser la formule suivante
Deacutelai = (GAPx1000)344
Deacutelai = ms (en millisecondes)GAP = distance du diffuseur du point de reacutefeacuterence (en megravetres)Vitesse du son = 344ms
d) MUTEChaque canal peut ecirctre placeacute en mute La mecircme commande peut ecirctre activeacutee dans la fenecirctre du menu meters NB Le mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) PhasePermet la rotation de phase de 180deg par rapport au signal entrantCette rotation permet loptimisation surtout des basses freacutequences dans les installations complexes
f) EGALISATIONCette commande ouvre la fenecirctre du menu deacutegalisation de chaque canal Elle sert surtout pour corriger une ou plusieurs freacutequences qui doivent ecirctre atteacutenueacutees ou augmenteacutees
M M
LAC26N gegravere 12 filtres par canal dentreacutee et sortie avec trois types de configurations diffeacuterentes - Leacutegaliseur PEQ (peaking equalizer) est ideacuteal pour identifier isoler et
corriger une seule plage de freacutequences bien deacutetermineacutee Toutes les freacutequences passent mais il augmente ou diminue uniquement celles autour de la freacutequence centrale pour une bande preacutecise et un gain deacutefini
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessus de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessous de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
f Numeacuterotation des 12 filtres disponibles pour cette entreacutee ou cette sortie1
f Le type de filtre est afficheacute 2
Dis Deacutesactiveacute (absent)
PEQ Peaking equlizer
Sh H Filtre high-shelf
Sh L Filtre high-shelf
Exemples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
REMARQUELe paramegravetre Bw deacutetermine le champ de freacutequences adjacent agrave la freacutequence configureacutee ougrave est activeacute le filtre Plus la valeur Bw est eacuteleveacutee plus vaste est le champ de freacutequences (1Bw=1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONCette commande ouvre la fenecirctre du menu de compression de chaque canal
g1) TresholdIdentifie le seuil ougrave commence le rapport de compression La valeur de base 11
g2) RatioIndique le rapport de conversion entre le signal entrant et le signal sortant
g3) Post Gain Attach Release HoldCes donneacutees deacutependent du rapport de conversion que lon veut obtenir - Post Gain est le gain de sortie- Attack est le temps dattaque - Release est le temps de relacircchement- Hold est le temps de maintien
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
52
DESCRIPTION DE LA FENETRE MENU Preset
Cette fenecirctre permet de meacutemoriser jusquagrave 32 configurations dans lAC26NLe fabricant fournit le systegraveme avec un programme configureacute et enregistreacute en position 0 et non susceptible deacutecrasement
032 Elle indique lemplacement de sauvetage de la configurationCe numeacutero apparaicirct dans la fenecirctre Meters en position (g) A tout moment le programme utiliseacute peut ecirctre afficheacute par lutilisateur
Empty Preset Cest le nom qui est associeacute au numeacutero de lemplacement quand aucune configuration (vide) nest enregistreacutee
Local preset Local preset est le nom qui est associeacute au numeacutero de lemplacement quand on enregistre une configuration NB = Il est possible denregistrer une configuration avec lenom souhaiteacute de 16 lettres tout au plus agrave condition que lonutilise linterface via lordinateur
Le nom du programme assigneacute est indiqueacutePour toucher agrave lapplication 3 choix soffrent agrave vous
Save Le programme est enregistreacute en meacutemoire de lAC26N
Del Le programme est effaceacute
Load Le programme est chargeacute et precirct agrave lemploi
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
51
DESCRIPTION DE LA FENETRE MENU X-Over
Cette fenecirctre permet de seacutelectionner un filtre passe bas un filtre passe haut ou par la combinaison des deux de creacuteer un filtre passe bande pour chaque sortieLe filtre actif est un Linkwitz-Riley qui permet de seacutelectionner la pente de 12dBoct 24dBoct ou 48dBoct et sa freacutequence de coupure
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) CANAUX DE SORTIE
Les connecteurs de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) FILTRE CROSSOVERSeacutelectionner le filtre selon les besoins Il est possible de seacutelectionner
Dis Aucun filtre activeacute
HP Filtre passe-haut laisse passer uniquement la partie de signal audio supeacuterieure agrave la freacutequence de coupure
LP Filtre passe-bas laisse passer uniquement la partie de signal audio infeacuterieure agrave la freacutequence de coupure
Configuration du filtre Passe-haut Passe-bas
Rien Dis Dis
Passe-haut HP Dis
Passe-bas Dis LP
Passe-bande HP LP
12dBoct
24dBoct
Hz
dB
Ga
in 48dBoct
12dBoct
24dBoct
Hz
dB
Ga
in
48dBoct
c) PENTE DATTENUATIONSeacutelectionner la pente datteacutenuation du signal audio en fonction de la diminution que lon veut obtenir Plus la pente datteacutenuation est eacuteleveacutee agrave eacutegaliteacute de freacutequence de coupure plus eacuteleveacutee sera la seacutelection du signal Il est possible de seacutelectionner
12 correspond agrave 12dboct
24 correspond agrave 24dboct
48 correspond agrave 48dboct
d) FREQUENCE DE COUPUREElle permet de reacutegler la freacutequence de passage des freacutequences infeacuterieures (filtre passe-bas) ou des freacutequences supeacuterieures (filtre passe-haut) uniquementLe choix de la coupure deacutepend de la reproduction que lon veut obtenirLuniteacute de mesure utiliseacutee est lHz
Hz
Hz
dB
dB
Ga
in
f0
f0
0dB0dB
0dB
-6dB
freacutequence
freacutequence
freacutequence
freacutequence
Ga
in
f0
0dB
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
53
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
54
DESCRIPTION DE LA FENETRE MENU Matrix
Elle permet de seacutelectionner le signal entrant agrave utiliser comme source pour chaque sortie
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) CANAUX DE SORTIEIdentification du canal sortant agrave reacutegler
b) IDENTIFICATIONS DES ENTREESSeacutelectionner le type de signal agrave associer agrave chaque sortie en fonction des besoins Il est possible de seacutelectionner
In A Le signal entrant A est associeacute
In B Le signal entrant B est associeacute
In A+B La somme algeacutebrique des deux signaux entrants A et B est associeacutee
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
DESCRIPTION DE LA FENETRE MENU Option
Permet dafficher les reacuteglages du systegraveme comme lassignation des entreacutees et des sorties latteacutenuation le contraste de laffichage et la version du logiciel
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcCette option permet de reacutegler le type de signal audio entrant
An In =signaux audio analogiques (entreacutees ldquoArdquo et ldquoBrdquo)
Dig In =signaux audio numeacuteriques (entreacutee AESEBU)
DigOut SrcCette option permet de seacutelectionner la source audio qui sera adresseacutee sur le connecteur AESEBU OUT (sortie numeacuterique)
An In = signaux audio des entreacutees analogiques
Dig In =signaux audio sur lentreacutee numeacuterique
OUT 1-2 = signaux audio sur les sorties 1 et 2
OUT 3-4 = signaux audio sur les sorties 3 et 4
OUT 5-6 = signaux audio sur les sorties 5 et 6
Input ModePermet de configurer les entreacutees
Indip = sont indeacutependantes et autonomes Ne sont soumises agrave aucun type de lien
Linked = sont unies et fonctionnent en mode steacutereacuteo Les compresseurs les filtres les deacutelais le volume sont identiques pour les deux canaux
Atten PadIndique le mode de reacuteglage du seacutelecteur ldquo-6dBrdquo placeacute agrave larriegravere [reacutef 5] Il faut activer ce seacutelecteur quand les niveaux dentreacutee analogiques sont trop eacuteleveacutes Le seacutelecteur sactive uniquement par le bouton Dans le menu il sagit dune simple visualisation
0dB = seacutelecteur non activeacute Les signaux dentreacutee sont identiques agrave la source entrante
-6dB = seacutelecteur activeacute Les signaux entrants sont atteacutenueacutes de -6dB par le processeur interne
ContrastIl permet de reacutegler le contraste de laffichage agrave cristaux liquides pour compenser la diffeacuterence de luminositeacute avec le lieu dinstallation Une plus grande clarteacute de laffichage permet de naviguer convenablement et rapidement dans les menusLe reacuteglage agrave la sortie de lusine du fabricant est de 60
10 plus clair 60 plus fonceacute 100
Fw VersIndique la version du logiciel du processeur
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
55
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
56
DONNES TECHINIQUES
PERFORMANCES AUDIOReacuteponse en freacutequence +- 01dB (20 to 30kHz)Plage dynamique 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsion 0002 (1kHz +4dBu)
PERFORMANCES AUDIO NUMERIQUES Processeur DSP 2856-bit Freacutequence de traitement des donneacutees 48KHzConvertisseurs analogiques 24-bit BURR BROWNDeacutelai de propagation 15msMeacutemorisations des configurations 32 preset
CONTROLES Affichage LCD graficoBoutonsCommandes ESC - MENU - FUNCTIONS SELECTION
ENTERENTREESSORTIESEntreacutee analogique ndeg2 x XLR (3 broches femelle)
Impeacutedance dentreacutee gt10KOhmNiveau maximum +21dBu senza PAD
+27dBu con PADSortie analogique ndeg6 x XLR (3 broches macircle )
Impeacutedance de sortie 50OhmNiveau maximum +21dBuType Balanceacute
Entreacutee numeacuterique ndeg1x XLR (3 broches femelle)Type SPDIF-AESEBU (AES3)
Sortie numeacuterique ndeg1x XLR (3 broches macircle )Type conforme agrave la norme de lentreacutee
EntreacuteesSortie Rdnet ndeg2 x XLR RJ45 (cacircble CAT 5)USB Type B
PARAMETRES DE CONTROLE DU SONGain -80dB a +20dB eacutetape 01dBDeacutelai Entreacutee 0 a 729mS eacutetape 01 mS
Sortie 0 a 340mS eacutetape 01mSRotation de phase 0deg - 180deg
COMPRESSIONSeuil -80dB a +20dB eacutetape 01dBRapport 11 a Inf1 eacutetape 001Gain agrave la sortie 0dB a 40dB eacutetape 01dBTemps dattaque 1mS a 1000mS eacutetape 01mSTemps de relacircchement 1mS a 1000mS eacutetape 01mSTemps de maintien 1mS a 1000mS eacutetape 01mS
EGALISEURS12 eacutegaliseurs pour chaque entreacutee et sortieType PEQ (parameacutetrique) Hi-shelf Lo-sheft
Freacutequence 20Hz a 20KHz eacutetape 1HzGain -30dB a +15dB eacutetape 001dBBande 005dB a 2dB eacutetape 001dB (uniquement pour PEQ)
FILTRES CROSSOVERFiltre Linkwitz Riley
Type HF high-shelfLF low-shelf
Pente 12dBoct - 24dBoct - 48dBoctFreacutequence de coupure 5Hz a 20KHz eacutetape 1Hz
ALIMENTATION Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)POIDS 19Kg
Remarques Speacutecifications sujettes agrave modifications sans preacuteavis
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
2 VIE ATTIVO2 WAY ACTIVE
3 VIE PASSIVO3 WAY PASSIVE
L
L
A
A
HIGH L
MID L
LOW HIGHMID RHIGHMID L
LOW L
HIGH R
MID R
LOW R
R
R
B
B
1
1
2
2
3
3
456
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
Menu Matrix configurationMatrix
57 58
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
EROUIG ATRIX TNM
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
OU
TP
UT
1
OU
TP
UT
2
OU
TP
UT
3
OU
TP
UT
4
OU
TP
UT
5
OU
TP
UT
6
AE
S-E
BU
OU
TP
UT
INP
UT
A
AE
S-E
BU
INP
UT
INP
UT
B
D D D D D D
D D
A A A A A A
A SA
MP
LE
RA
TE
CO
NV
A
LIN
KA
BL
E
SC
HE
MA
A B
LO
CC
HI -
BL
OC
K D
IAG
RA
MB
LO
CK
SC
HA
LT
BIL
D -
SC
HE
MA
S F
ON
CT
ION
NE
LS
LINE ARRAY SUB MONO ATTIVO
LINE ARRAY SUB MONO ACTIVEINGRESSI - INPUT
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
L
L
L
A
A
A
AESEBU IN
AESEBU IN
AESEBU IN
AESEBU OUT
AESEBU IN
AESEBU IN
AESEBU OUT
R
R
R
LR
B
B
B
123456
HIGHMID L
HIGHMID L HIGHMID R
HIGHMID R
LOW L LOW R
LAYER
DISPLAY MEMORY
FADER MODE
LAYER
DISPLAY MEMORY
FADER MODE
Ingresso ANALOGICO
ANALOG Input
Collegamento in cascata
Link connections
Ingresso DIGITALE
DIGITAL inputA B
BALANCED AUDIO INPUTS
-6dB
PUSH PUSH
IN OUT
AES EBUPUSH
Oppure
or
Oppure
or
Menu Option configurationOption
Menu Option configurationOption Menu Option configurationOption
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type Analog
AES out An In
Input type Analog
AES out An In
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
59 60
InA-B Src Dig InInA-B Src Dig InInA-B Src An InInA-B Src An In
frequenzaHz
dB
Gu
ad
ag
no
60 200 2800
0dB0dB
-6dB
Esempio di un sistema a 3-vie
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
Out 1 Out 2 Out 3
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Esempio di un sistema a 3-vie
61 62
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
26NAC 26NAC
R TE
DO
R
MO LEU O R CE S
E O TR L A
S O
O C ND I P
P hsuernE t
o su cti nF nel rS e tc o
E CSME UN
IGCHTE OL SN EOBd
ocaL l
M
0
484
467
430
44
31
75
12
7
DIMENSIONI DIMENSIONSABMESSUNGEN DIMENSIONS
7
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
8
a) CANALI INGRESSO E USCITAI connettori di ingresso ed uscita sono identificati utilizzando le medesime indicazioni presenti sulla serigrafia del retro del dispositivoCon segnali di ingresso digitali lrsquoindicazione ldquoArdquo e ldquoBrdquo corrispondono allrsquoingressoRuotando la manopola ldquoFUNCTIONS SELECTORrdquo [2] si scorrono in modo ciclico i canali ingresso uscita e indicazione di mute generale (d) il canale selezionato viene evidenziato
COMPRESSIONE SEGNALELa compressione del segnale viene visualizzata tramite lo scorrimento della barra di destra dallrsquoalto verso il basso
MUTE Ogni singolo canale puograve essere posto nelle condizione di mute Selezionare il canale e premere la manopola ldquoPush Enterrdquo [2] per confermare il cambiamento di stato Alla indicazione del canale verragrave sostituita la lettera ldquoMrdquo e la barra verragrave completamente evidenziataPer ripristinare il funzionamento normale ripetere le precedenti azioni descritte
c) BARRA LIVELLO SEGNALELrsquoindicazione del livello di ogni singolo canale viene segnalato tramite lo scorrimento delle barra di sinistra
d) MUTE GENERALEErsquo possibile mettere in mute tutti gli ingressi e le uscite contemporaneamente Ruotare la manopola ldquoFUNCTIONS SELECTORrdquo [2] selezionare la lettera ldquoMrdquoe premere la manopola ldquoPush Enterrdquo [2]Per ripristinare il funzionamento normale ripetere le precedenti azioni descritteIl mute generale ha la prioritagrave piugrave alta rispetto ai mute dei singoli canali
b) BARRA LIVELLO COMPRESSIONEMUTE CANALE
e) MODALITArsquo DI COMANDOViene visualizzato come egrave utilizzato eo a quali dispositivi egrave collegato lrsquo AC26N
Local = utilizzo stand-alone Nessuna connessione ad un dispositivo esterno
NET = collegato direttamente alla rete dedicate RDnet e al computer
USB = collegato direttamente ad un computer tramite cavo USB
f) INDICAZIONE STATO IMPOSTAZIONITramite questa indicazione viene visualizzato se il programma caricato egrave stato modificato in uno o piugrave parametri rispetto allrsquoultimo salvataggio
= programma originale
= programma con parametri modificati
g) PROGRAMMA IMPOSTATOIl numero indica il programma caricato ed utilizzato dal sistema riferito alla locazione di salvataggio Fare riferimento al menugrave di ldquoPresetrdquo per ulterioi dettagli
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
DESCRIZIONE FINESTRA MENUrsquo ldquoCh Jobrdquo
Questa finestra permette di visualizzare la configurazione di ogni singolo canale
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) CANALI INGRESSO E USCITAI connettori di ingresso ed uscita sono identificati utilizzando le medesime indicazioni presenti sulla serigrafia del retro del dispositivo
b) LIVELLO DEL SEGNALEIndica guadagno del segnale Laumento nella intensitagrave di un segnale egrave espresso in decibel (dB) Il parametro puograve essere selezionato da -8000dB a +2000dB con passi di 001dB Un aumento di 6dB egrave approssimativamente uguale al raddoppiamento in scala lineare del livello in tensione del segnaleCon un guadagno maggiore di 0dB viene amplificato il segnale mentre con un guadagno inferiore di 0dB viene attenuato il segnale
c) RITARDO DEL SEGNALE (DELAY)I segnale audio riprodotto puograve essere ritardato per permettere lrsquoallineamento acustico Questo compensa le diverse posizioni dei diffusori durante lrsquoinstallazione e la riproduzione sonora ed egrave espresso il mS Il parametro puograve essere selezionato da 00mS a 729mS con passo 01mSPer allineare un segnale audio egrave possibile utilizzare la seguente formula
Ritardo = (GAPx1000)344
Ritardo = ms (espresso in millisecondi)GAP = distanza del diffusore dal punto di riferimento (espresso in metri)
Velocitagrave del suono = 344ms
d) MUTEOgni singolo canale puograve essere posto nella condizione di mute Lo stesso comando puograve essere attivato nella finestra del menugrave laquometersraquo NB Il mute generale ha la prioritagrave piugrave alta rispetto ai mute dei singoli canali
e) FASEPermette la rotazione di fase di 180deg rispetto al segnale in ingressoQuesta rotazione permette lrsquoottimizzazione soprattutto delle basse frequenze nelle installazioni complesse
f) EQUALIZZAZIONEQuesto comando apre la finestra del menugrave dellrsquoequalizzazione del singolo canale Viene principalmente utilizzato per correggere una o piugrave frequenze che devono essere attenuate oppure aumentate
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
109
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
oLrsquo AC26N gestisce 12 filtri per ogni singolo canale di ingresso e uscita con tre diversi tipi configurazioni
Passano tutte le frequenze ma aumenta e diminuisce solo quelle attorno alla frequenza centrale per una determinata banda e un guadagno stabilito
- Equalizzatore high-shelf passa tutte le frequenze ma aumenta o attenua le frequenze sopra la frequenza di taglio selezionata per il guadagno indicato
- Equalizzatore low-shelf passa tutte le frequenze ma aumenta o attenua le frequenze inferiori alla frequenza selezionata per il guadagno indicato
- Equalizzatore PEQ (peaking equalizer) egrave ideale per identificare isolare e correggere solo una determinata gamma di frequenze
f Numerazione dei 12 filtri disponibili per quellrsquoingresso oppure uscita1
f Viene visualizzato il tipo di filtro2
Dis Disinserito (non presente)
PEQ Peaking equalizer
Sh H Filtro high-shelf
Sh L Filtro low-shelf
Esempi PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
NOTA BENEIl parametro Bw determina il campo di frequenze adiacenti alla frequenza impostata dove viene attivato il filtro maggiore egrave il valore Bw maggiore e egrave il campo di frequenze (1Bw=1 ottava)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONEQuesto comando apre la finestra del menugrave compressione del singolo canale
g ) Treshold1
Identifica la soglia dove inizia il rapporto di compressione Il valore di base 11
g ) Ratio2
Indica il rapporto di conversione tra il segnale in ingresso e quello in uscita
g ) Post Gain Attach Release Hold3
Questi dati sono in funzione del rapporto di conversione che si vuole ottenerePost Gain egrave il guadagno di uscitaAttack egrave il tempo di attacco Release egrave il tempo di rilascioHold il tempo di mantenimento
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
DESCRIZIONE FINESTRA MENUrsquo ldquoPresetrdquoQuesta finestra permette di memorizzare fino a 32 configurazioni nellrsquoAC26NLa ditta costruttrice fornisce il sistema con un programma impostato e salvato nella posizione ldquo0rdquo e non sovrascrivibile
032 Indica la locazione di salvataggio della configurazioneQuesto numero appare anche nella finestra ldquoMetersrdquo nella posizione (g) in qualsiasi momento il programma utilizzato puograve essere visualizzato dellrsquoutente
Empty Preset Ersquo il nome che viene associato al numero della locazione quando non egrave salvato nessun settaggio (vuoto)
Local preset Ersquo il nome che viene associato al numero di locazione quando viene salvata una configurazione NB = Ersquo possibile salvare un settaggio con il nome desiderato al max 16 lettere solo utilizzando lrsquointerfaccia tramite il computer
Selezionando un programma appare la seguente finestra
Viene indicato il nome del programma assegnatoPer intervenire sulla applicazione sono a disposizione 3 scelte possibili
Save Il programma viene salvato nella memoria dellrsquoAC 26N
Del Il programma viene cancellato
Load Il programma viene caricato e pronto per essere utilizzato
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
11
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
12
DESCRIZIONE FINESTRA MENUrsquo ldquoX-OverrdquoQuest a finestra permette di selezionare per ogni uscit a un filtro p assa basso un filtro p assa alto oppure tramite la combinazione di entrambe creare un filtro p assa bandaIl filtro presente egrave un Linkwitz-Riley dove egrave possibile selezionare la pendenza di 12dBoct 24dBoct oppure 48dBoct e la relativa frequenza di t aglio
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) CANALI USCITA
I connettori di uscita sono identificati utilizzando le medesime indicazioni presenti sulla serigrafia del retro del dispositivo
b) FILTRO CROSSOVERSelezionare il filtro a seconda delle necessitagrave Ersquo possibile selezionare
Dis Nessun filtro attivato
HP Filtro passa-alto lasciare passare solo la parte di segnale audio superiore alla frequenza di taglio
LP Filtro passa-basso lasciare passare solo la parte di segnale audio inferiore alla frequenza di taglio
Configurazione Filtro Passa basso Passa alto
Nessuna Dis Dis
Passa alto HP Dis
Passa basso Dis LP
Passa banda HP LP
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
c) PENDENZA DI ATTENUAZIONESelezionare la pendenza di attenuazione del segnale audio in base alla diminuzione che si desidera ottenere Piugrave elevata egrave la pendenza di attenuazione a paritagrave di frequenza di taglio maggiore egrave la selezione del segnale Ersquo possibile selezionare
12 corrisponde a 12dboct
24 corrisponde a 24dboct
48 corrisponde a 48dboct
d) FREQUENZA DI TAGLIOPermette drsquoimpostare la frequenza di passaggio delle sole frequenze inferiori (filtro passa-basso) o delle sole frequenze superiori (filtro passa-alto)La scelta del taglio egrave in funzione della riproduzione che si vuole ottenereLrsquounitagrave di misura utilizzata egrave Hz
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
DESCRIZIONE FINESTRA MENUrsquo ldquoMatrixrdquoPermette di selezionare per ogni uscita il segnale in ingresso da utilizzare come sorgente
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) CANALI USCITAIdentificazione del canale in uscita da impostare
b) IDENTIFICAZIONI INGRESSISelezionare il tipo di segnale da abbinare a ogni singola uscita in base alle proprie necessitagrave Ersquo possibile selezionare
In A Viene associato il segnale in ingresso laquoAraquo
In B Viene associato il segnale in ingresso laquoBraquo
In A+B Viene associato la somma algebrica dei due segnali in ingresso laquoAraquo e laquoBraquo
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
DESCRIZIONE FINESTRA MENUrsquo ldquoOptionrdquoPermette di visualizzare le impostazioni sistema come lrsquoassegnazione degli ingressi e delle uscite attenuazione il contrasto del display e la versione del firmware
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711
InA-B SrcQuesta opzione permette di impostare il tipo di segnale audio in ingresso
An In = segnali audio analogici (ingressi ldquoArdquo e ldquoBrdquo)
Dig In = segnali audio digitali (ingresso AESEBU)
DigOut SrcQuesta opzione permette di selezionare la sorgente audio che verragrave indirizzata sul connettore AESEBU OUT (uscita digitale)
An In = segnali audio presenti negli ingressi analogici
Dig In = segnali audio presenti sullrsquoingresso digitale
OUT 1-2 = segnali audio presenti sulle uscite 1 e 2
OUT 3-4 = segnali audio presenti sulle uscite 3 e 4
OUT 5-6 = segnali audio presenti sulle uscite 5 e 6
Input ModePermette di configurare gli ingressi
Indip = sono indipendenti ed autonomi non sono soggetti a vincoli di alcun genere tra di loro
Linked = sono uniti e funzionano in modalitagrave stereoI compressori i filtri i ritardi il volumesono identici per i due canali
13
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
14
Atten Pad
Indica come egrave impostato il selettore ldquo-6dBrdquo posto sul retro [rif 5] Ersquo necessario attivare questo selettore quando i livelli di ingresso analogici sono troppo elevati Il selettore viene attivato solo tramite il pulsante nel menugrave egrave solo una visualizzazione
0dB = selettore non attivatoI segnali di ingresso sono i medesimi della sorgente in ingresso
-6dB = selettore attivatoI segnali in ingresso vengono attenuati di -6dB dal processore interno
Contrast
Consente di regolare il contrasto del display LCD per compensare la differenza di luminositagrave con il luogo di installazione Una maggiore chiarezza del display permette di navigare allrsquointerno dei menugrave in modo corretto e veloceIl settaggio in uscita dalla ditta produttrice egrave 60
10 piugrave chiaro 60 piugrave scuro 100
Fw Vers
Indica la versione del firmware del processore
SPECIFICHE TECNICHE
PRESTAZIONI AUDIORisposta in frequenza +- 01dB (20 to 30kHz)Gamma dinamica 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsione 0002 (1kHz +4dBu)
PRESTAZIONI AUDIO DIGITALI Processore DSP 2856-bit Frequenza elaborazione dati 48KHzConvertitori analogici 24-bit BURR BROWNRitardo di propagazione 15msMemorizzazioni configurazioni 32 preset
CONTROLLI Diplay LCD graficoPulsantiComandi ESC - MENU - FUNCTIONS SELECTION
ENTER
INGRESSIUSCITEIngresso analogico ndeg2 x XLR (3 poli femmina)
Impedenza di ingresso gt10KOhmLivello massimo +21dBu senza PAD
+27dBu con PADUscita analogica ndeg6 x XLR (3 poli maschio)
Impedenza di uscita 50OhmLivello massimo +21dBu Tipo Bilanciato
Ingresso digitale ndeg1x XLR (3 poli femmina)Tipo SPDIF-AESEBU (AES3)
Uscita digitale ndeg1x XLR (3 poli maschio)Tipo conforme allo standard dellrsquoingresso
IngressiUscita RDnet ndeg2 x XLR RJ45 (cavo CAT 5)USB Tipo B
PARAMETRI CONTROLLO AUDIOGuadagno -80dB a +20dB passo 01dBRitardo
ingresso 0 a 729mS passo 01 mSuscita 0 a 340mS passo 01mS
Rotazione di fase 0deg - 180deg
COMPRESSIONESoglia -80dB a +20dB passo 01dBRapporto 11 a Inf1 passo 001Guadagno in uscita 0dB a 40dB passo 01dBTempo di attacco 1mS a 1000mS passo 01mSTempo di rilascio 1mS a 1000mS passo 01mSTempo di mantenimento 1mS a 1000mS passo 01mS
EQUALIZZATORI12 equalizzatori per ogni ingresso e uscitaTipo PEQ (parametrico) Hi-shelf Lo-sheft
Frequenza 20Hz a 20KHz passo 1HzGuadagno -30dB a +15dB passo 001dBBanda 005dB a 2dB passo 001dB (solo per PEQ)
FILTRI CROSSOVERFiltro Linkwitz Riley
Tipo HP Passa-AltoLP Passa-Basso
Pendenza 12dBoct - 24dBoct - 48dBoctFrequenza di taglio 5Hz a 20KHz passo 1Hz
ALIMENTAZIONE Full-range 100-240Vac 50-60HzDIMENSIONI 430482x43x130mm (LxHxD)PESO 19Kg
Note Specifiche soggette a variazioni senza preavviso
CLASSIFICAZIONE EMIIn accordo alle normative EN 55103 lapparato egrave progettato e idoneo allutilizzo in ambienti Elettromagnetici E3 o inferiori (E2 E1)
INTRODUCTIONAC26N is a digital sound processor for the management of audio systems designed for fixed and touring installations AC26N uses the most modern technology with 2856 bit processors and high performance 24 bits ADDA converters The functions available in the processor are input and output levels delay polarity 12 equalization bands for each input and output channel multiple crossover and high performance limiter The control resolution of the filters is 1Hz Inputs and outputs can be set according to many configurations to meet any need AC26N can be controlled in real time and each one of its parameters can be configured on the front panel and through a computer by means of an intuitive graphical interface accessible through the software DVA Network and a dedicated RDnet or USB network connectionThe CPU and DSP software update via PC allows to keep the device up to date It is possible to save and recall 32 preset configurations
Package Contents- AC26N - Operating manual- Software CD- Power cord
Characteristics- 2 Inputs and 6 Outputs with flexible routing- AESEBU addressable stereo inputs and outputs - 2856 bit DSP- BURR-BROWN high performance 24 bit AD converters- Frequency resolution of the filters 1 Hz - 12 parametric equalizers for each input and output- 2 crossover filters for each output with selectable slope 122448 dBoct- High performance DRC multi configuration for limitercompression configuration of
each input and output- Adjustable level in dB polarity and delay for each input and output- Firmware Update via PC- Graphic LCD Display- 32 pre-sets can be stored by the user- USB interface for configuration and control via computer- RDnet interface that allows to control up to 256 remote devices
PC
PC
RDNET hub(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FUNCTIONS FRONT PANEL
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
CONTROLS AND FUNCTIONS
1) DISPLAYThe graphic LCD display allows to view and edit the AC26N information without a computer The display contrast can be set within the main menu
2) ldquoFunctions Selectorrdquo and ldquoPush Enterrdquo KNOBThis control allows to move select and change the parameters within the displayed menusRotation of the knob (Function Selector)- it allows to browse the menu pages- it allows to change the selected parametersPush the knob (Push Enter)- it allows to selectconfirm the parameters
3) ESC button This control allows to exit the displayed menus or to return to the previous view
4) MENU button This control allows to directly access the main menu
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
En
glis
hE
nglis
hu
ser
man
ual
user
man
ual
16
user
man
ual
user
man
ual
Englis
hE
nglis
h
15
DVA USB Manager
The firmware of the amplifier module can be updated via the USB portTo make this update possible and simple a dedicated program has been developed
It is recommended to download DVA USB Manager free software directly from dB Technologies (wwwdbtechnologiescom) in the special section laquoSoftware amp Controllerraquo
DVA Network
The AC26N is equipped with proprietary network interface called RDNET for PC interface through a device (RDNET control)For this purpose a proprietary communication protocol has been developed for receiving and sending data this connection permits real-time monitoring of the diffuser parameters such as output power amplifier temperature limiter status etc It is also possible to select various equalizations or create new ones set the desired volume levels using the specific plug-in
It is recommended to download DVA Network free software directly from dB Technologies (wwwdbtechnologiescom) in the special section laquoSoftware amp Controllerraquo DOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
REAR PANEL CONNECTIONS
1586 75 141210 11 13 169 17
14) USB connectorThis USB connector (type B) allows to connect the processor to a compute to check and update the firmware via a dedicated program (DVA Network)
15) ldquoMAINSrdquo POWER CONNECTIONIt allows to connect the provided power cord
16) FUSE HOLDER ldquoFUSErdquoMain power supply fuse housing
17) ldquoPOWERrdquo MAIN SWITCHThis switch allows to switch on and off the device
PUSH
P SHU
SHPU
P SHU
PUSH
CONNECTIONS
Analog Audio ConnectionsBalanced connections allow to minimize the cable induced noise so cable can be longerSuch connections may be used both on inputs and outputsXLR connector must be cabled with pin 1 to ground pin 2 to hot (+) and pin 3 to cold (-) With shielded cables connect the shield to pin 1XLR-XLR e XLR-Jack 14(63 mm) connection cables can be used to connect the AC26N
12
3
Input
XLR - female
Pin 3 =NegativeCold-VE Phase
Pin 3 =NegativeCold-VE Phase
1 2
3
Output
XLR - Male
Pin 2 = PositiveHot+VE Phase
Pin 2 = PositiveHot+VE Phase
Pin 2 = PositiveHot+VE Phase
Pin 2 = PositiveHot+VE Phase
Pin 1 =ScreenGroundEarth
Pin 1 =ScreenGroundEarth
Pin 1 =ScreenGroundEarth
Pin 1 =ScreenGroundEarth
Ring
Sleeve
Tip = PositiveHot+VE Phase
Ring = NegativeCold-VE Phase
Sleeve=ScreenGroundEarth
Sleeve=ScreenGroundEarth
Tip
The unbalanced connections can also be used However the cable induced noise increases and cable length must not exceed 5 metersSuch connections may be used both on inputs and outputsUnbalanced connection may lower the level of the input signal up to 6dB in order to overcome this drawback connect pin 3 to ground although this can increase the noise
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
18
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
17
CONTROLS AND FUNCTIONS
5) -6dB SELECTORThis selector allows to reduce all the analog XLR [6] input levels by 6 dB at the same time to compensate for the high output levels on the mixers or other audio devices When the input signal level bar on the display [1] remains always at full scale this means that the input signal level is excessive and a -6 dB attenuation is recommendedIn the Option menu it is possible to check when the selector is activated
6) INPUT CONNECTORS ldquoArdquo AND ldquoBrdquoInputs balanced at line levelCapable to accept XLR male connectors
7) OUTPUT CONNECTORS ldquo1rdquo ldquo2rdquordquo 3rdquo ldquo4rdquo ldquo5rdquo AND ldquo6rdquoOutputs balanced at line level Capable to accept XLR famale connectors
Be careful to correctly connect each output to each speaker or amplifier according to the settings of each channels to avoid damages and malfunctions
ldquoAESEBUrdquo Section
8) INPUT CONNECTORIn addition to the analog audio inputs a SPDIF-AESEBU (AES3) digital audio input is also provided It can be selected via the setup menuSuch input requires a balanced connection trough an XLR connector with a 110 ohm twisted 3-wires cable
9) ldquoOUTrdquo OUTPUT CONNECTORThis connector allows to forward audio signals available at the digital or analog inputs or outputs The source must be set by means of the Option menuThe connection must comply with the same standard of the input [8]
RDNET Section
10) DATA INPUT CONNECTORData input RJ45 connector
11) ldquoDATA LINKrdquo OUTPUT CONNECTORRJ45 connector for data output used for serial link in cascade
12) ldquoONrdquo INDICATOR LIGHTThis green indicator turns on only when the AC26N has recognized the RDNET main unit and it is connected to it via computer
13) ldquoACTIVErdquo INDICATOR LIGHTThis yellow indicator flashes when data transmission between RDNET and the device is active
12
3
Input
XLR - female
1 2
3
Output
XLR - Male
Tip Gambo
Tip= Signal
Pin 3 = Link to Pin 1
Pin 3 = Link to Pin 1
Digital Audio Connections (AESEBU)AESEBU (AES3 protocol) is and a balanced input electrically insulated by means of a transformer It allows carrying two audio channels in a single two-wires shielded cable The cable characteristics are twisted 3 poles impedance 100 ohm shielded equipped with XLR connector (AES3 standard)
RDnetEach RDNet port on Control 2 and Control 8 can be connected to maximum 32 cascade-connected compatible devices In the example below the control unit RDNET CONTROL 2 port is connected to the DATA INPUT of an AC 26N whose parallel DATA LINK output is sent to the input of the next AC26N In the example [n] is a number between 3 and 32 (maximum limit for the devices connected to a sub-network)
RJ 45
|1|2|3|4|5|6|7|8|
The overall length of a CAT5 sub-network cable cannot exceed 900 meters
The connector must be connected as follows
1 - Available for other functions (for example audio +) 2 - Available for other functions (for example audio -)3 - Available for other functions (for example analog ground)4 - digital ground5 - digital ground6 - Available for other functions (for example power supply)7 - RS 485 A8 - RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
POWER ON
When the device is turned on the initialization procedure starts It lasts few seconds The display shows the device model the company logo and a program loading progress bar
At the end of the installation process the display shows the Meters menu For further details about the indications refer to the paragraph MENU DESCRIPTION - METERS
AC26N is now ready for use
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION AND DISPLAY
To access the main menu window press the MENU key located on the device front panelIn any page of the menu press the ESC button to return to the previous screen
MAIN MENU
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
There are six menus in the processor They show andor configure the system parametersThe main menus are
Meters Input and output levels display program in progress display quick muting
Preset Store save and delete the system configurations
Matrix Select the outputs according to the input signal
Ch Job Configuration of each individual channel
X-Over Configuration of the cut-off frequency and the types of filters for each output
Option Assignment of the inputs and outputs display contrast firmware version inputs and other options
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
20
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
19
The menus and the individual options displayed can be selected by rotating the knob ldquoFUNCTION SELECTORrdquo ( ) To access the selection highlight the desired parameter and press the ldquoPush Enterrdquo ( | ) knobThe same procedure should be adoptd to select andor change the options inside each menu entry
MENU DESCRIPTION - ldquoMetersrdquo
This window allows to view the configuration and the general conditions of the inputs and outputs the version of the program used the program status and how the system is driven
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) INPUT AND OUTPUT CHANNELSThe input and output connectors are identified by the same information provided on the screen printing located on the device rear sideWith digital input signals the indications A and B concern the inputBy rotating the knob FUNCTION SELECTOR [2] input channels output channels and general muting indications are cyclically scrolled (d) the selected channel is highlighted
b) BAR COMPRESSION LEVEL CHANNEL MUTING
SIGNAL COMPRESSIONSignal compression is displayed by the vertical scrolling (top to down) of the right bar
MUTE Each channel can be individually muted Select the channel and press the Push Enter knob [2] to confirm the change of status The indication of the channel will be replaced by the letter M and the bar will be completely highlightedTo restore normal operation repeat the actions described above
c) SIGNAL LEVEL BARThe level indication for each channel is provided by scrolling the left bar
d) GENERAL MUTINGIt is possible to mute all the inputs and outputs simultaneously Rotate the knob FUNCTION SELECTOR select the letter M and press the Push Enter knobTo restore normal operation repeat the actions described aboveThe general mute has the highest priority with respect to the muting of individual channels
e) CONTROL MODEIt shows how the AC26N is used andor to which devices it is connected
Local = stand-alone usage No connection to an external device
NET = directly connected to dedicated RDnet network and to computer
USB = directly connected to another computer via USB cable
f) SETTING STATUS INDICATIONThis indication shows if the loaded program was amended in one or more parameters with respect to the last saving operation
= original program
= program with modified parameters
g) SET PROGRAMThe number shows the program that is loaded and used by the system with reference to the saving position Refer to the ldquoPresetrdquo menu for further details
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
MENU DESCRIPTION - CH JOB
This window allows to view the configuration of each individual channel
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) INPUT AND OUTPUT CHANNELSThe input and output connectors are identified by the same information provided on the screen printing located on the device rear side
b) SIGNAL LEVELIt shows the signal gain The increased signal intensity is expressed in decibels (dB) Such parameter can be selected in the range from -8000 dB to +2000 dB in steps of 001 dB An increase of 6 dB is approximately equal to doubling - in a linear scale - the signal voltage levelIf the gain exceeds 0 dB the signal is amplified while if the gain is lower than 0 dB the signal is attenuated
c) SIGNAL DELAYThe reproduced audio signal may be delayed to perform an acoustic alignment This compensates for the different positions of the speakers during the installation and the sound reproduction it is expressed in ms The parameter can be selected in the range from 00 ms to 729 ms in steps of 01 msThe following formula can be used to align an audio signal
Delay = (GAPx1000)344
Delay = ms (in milliseconds)GAP = distance between speaker and reference point (in meters)Speed of sound = 344 ms
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
22
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
21
d) MUTEEach channel can be individually muted The same command can be activated in the Meters Menu
NOTE The general mute has the highest priority with respect to the muting of individual channels
e) PhaseIt performs a phase rotation of 180deg with respect to the input signalSuch phase rotation allows the optimization in special way for low frequencies in complex installations
M M
f) EQUALIZATIONThis control opens the menu controlling the single channel equalization It is mainly used to correct one or more frequencies that must be reduced or increased
The AC26N manages 12 filters for each individual channel input and output with three different kinds of configuration
- PEQ Equaliser (peaking equalizer) ideal to identify isolate and correct only a certain range of frequencies All frequencies pass only those around the centre frequency are increased and decreased for a given bandwidth and set gain
- High-shelf Equalizer All frequencies pass but frequencies above the selected cut-off frequency are increased or attenuated by the given gain
- Low-shelf Equalizer All frequencies pass but frequencies below the selected cut-off frequency are increased or attenuated by the given gain
f Numbering of the 12 available filters for the specific input or output1
f Displays the kind of filter2
Dis Switched off (not present)
PEQ Peaking equlizer
Sh H High-shelf Filter
Sh L Low-shelf Filter
Examples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
NOTE
The parameter Bw defines the range of frequencies close to the set frequency where the filter is activated the greater the value of Bw the wider is the frequencies range (1 Bw = 1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONThis control opens the menu controlling the compression for the single channel
g1) ThresholdIdentifies the starting threshold for the compression ratio Base value 11
g2) RatioIndicates the conversion ratio between input and output signal
g3) Post Gain Attach Release HoldThese data are in function of the conversion ratio to achieve Post Gain is the output gain Attack is the attack time Release is the release time Hold is the holding time
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
24
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
23
MENU DESCRIPTION - PRESET
This window allows to store up to 32 configurations in the AC26NThe manufacturer provides the system with a program set and saved in position 0 that is not possible to overwrite
032 Indicates the location where the configuration is savedThis number also appears in the window Meters in position (g) The program in use can be displayed at any time by the user
Empty Preset It is the name associated with the location number when no setting is saved (empty)
Local preset It is the name associated with the location number when a setting is saved NOTE = It is possible to save a setting with the desired name up to 16 letters only via the computer interface
When a program is selected the following window is displayed
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
The name of the assigned program is displayed3 possible choices are available when working on the application
Save The program is saved in the AC 26N memory
Del The program is deleted
Load The program is loaded and ready to be used
MENU DESCRIPTION - X-OVER
This window allows to select for each output a low pass filter a high pass filter or create a band-pass filter via the combination of bothThe available filter is a Linkwitz-Riley where it is possible to select slopes of 12 dBoct 24 dBoct or 48 dBoct and their cut-off frequency
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) OUTPUT CHANNELS
The output connectors are identified by the same information provided on the screen printing located on the device rear side
b) CROSSOVER FILTERSelect the filter according to needs It is possible to select
Dis No filter enabled
HP High-pass filter set it to allow only the part of audio signal above the cut-off frequency
LP Low-pass filter set to allow only the part of audio signal below the cut-off frequency
Filter configuration Low-pass High-pass
Nothing Dis Dis
High-pass HP Dis
Low-pass Dis LP
Band-pass HP LP
12dBoct
24dBoct
Hz
dB
48dBoct
12dBoct
24dBoct
frequency
frequency
frequency
frequency
Hz
dB
48dBoct
c) ATTENUATION SLOPESelect the attenuation slope of the audio signal on the basis of the desired attenuation The higher the attenuation slope at the same cut-off frequency the greater the signal selection It is possible to select
12 equal to 12 dBoct
24 equal to 24 dBoct
48 equal to 48 dBoct
d) CUT-OFF FREQUENCYTo set the passing frequency for the lower frequencies only (low-pass filter) or the higher frequencies only (high-pass filter)The choice of the cut-off depends on the desired sound reproductionThe unit of measurement used is Hz
Hz
Hz
dB
dB
Ga
inG
ain
Ga
inG
ain
f0
f0
0dB0dB
0dB
-6dB
-6dB
0dB
0dB
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
26
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
25
MENU DESCRIPTION - MATRIX
For each output it allows to select the input signal to use as the source
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) OUTPUT CHANNELSIdentification of the output channel to set
b) IDENTIFICATIONS OF THE INPUTSIt selects the type of signal to match each output as needed It is possible to select
In A Associated with the input signal ldquoArdquo
In B Associated with the input signal ldquoBrdquo
In A+B Associated with the algebraic sum of the two input signals ldquoArdquo and ldquoBrdquo
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
MENU DESCRIPTION - OPTION
Allows to display the system settings such as the allocation of the inputs and outputs attenuation display contrast and firmware version
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcThis option allows to set the type of input audio signal
An In = Analog audio signals (inputs A and B)
DigIn = Digital audio signals (AESEBU input)
DigOut SrcThis option allows to select the audio source that will be forwarded to the connector AESEBU OUT (digital output)
An In = Audio signals available at analog inputs
Dig In = Audio signals available at digital inputs
OUT 1-2 = Audio signals available on outputs 1 and 2
OUT 3-4 = Audio signals available on outputs 3 and 4
OUT 5-6 = Audio signals available on outputs 5 and 6
Input ModeIt allows to configure the inputs
Indip = They are independent not subject to constraints of any kind between them
Linked = They are connected and work in stereo mode Compressors filters delays volume are identical for the two channels
Atten PadIt shows how to set the -6 dB switch located on the rear side [Ref 5] It is necessary to activate this selector when the analog input levels are too high The selector can be activated only by means of the button the menu is for display only
0 dB = Selector not activated The input signals are the same as the input source
-6 dB = Selector activated The input signals are attenuated by -6 dB with reference to the inner
processor
ContrastAllows to adjust the LCD display contrast to compensate for the brightness difference at the installation sites Greater display brightness allows to navigate correctly and quickly within the menuThe manufacturer output setting is 60
10 More bright 60 More dark 100
Fw VersIt shows the processor firmware version
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
28
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
27
TECHINICAL SPECIFICATION
AUDIO PERFORMANCEFrequency Response +- 01dB (20 to 30kHz)Dynamic Range 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistortion 0002 (1kHz +4dBu)
DIGITAL AUDIO PERFORMANCE Processor DSP 2856-bit Data processing Frequency 24-bit BURR BROWNAnalog converters 24-bit BURR BROWNPropagation Delay 15msStoring configurations 32 preset
CONTROLS Display LCD graficoButtonsControls ESC - MENU - FUNCTIONS SELECTION
ENTERINPUTSOUTPUTSAnalog Input ndeg2 x XLR (3 pole female)
Input impedance gt10KOhmMaximum Level +21dBu senza PAD
+27dBu con PADAnalog Output ndeg6 x XLR (3 pole male)
Output impedance 50OhmMaximum Level +21dBu Type Balanced
Digital Input ndeg1x XLR (3 pole female)Type SPDIF-AESEBU (AES3)
Digital Output ndeg1x XLR (3 pole male)Type Compliant with the input standard
RDnet InputsOutput ndeg2 x XLR RJ45 (CAT 5 cable)USB Tipo B
SOUND CONTROL PARAMETERSGain -80dB a +20dB step 01dBDelay
Input 0 a 729mS step 01 mSOutput 0 a 340mS step 01mSPhase Rotation 0deg - 180deg
COMPRESSIONThreshold -80dB a +20dB step 01dBRatio 11 a Inf1 step 001Output gain 0dB a 40dB step 01dBAttack time 1mS a 1000mS step 01mSRelease time 1mS a 1000mS step 01mSHold time 1mS a 1000mS step 01mS
EQUALIZERS12 equalizers for each input and outputType PEQ (parametrico) Hi-shelf Lo-sheft
Frequency 20Hz a 20KHz step 1HzGain -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (only with PEQ)
CROSSOVER FILTERSFilter Linkwitz Riley
Type HP High-pass LP Low-pass
Slope 12dBoct - 24dBoct - 48dBoctCUT-OFF FREQUENCY 5Hz a 20KHz passo 1Hz
POWER SUPPLY Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)
1719x17x51 inch (WxHxD)WEIGHT 19Kg
(42 lbs)Note Specifications subject to change without notice
EMI CLASSIFICATIONAccording to the standards EN 55103 this equipment is designed and suitable to operate in E3 (or lower E2 E1) Electromagnetic environments
EINLEITUNG
Verpackungsinhalt
Eigenschaften
AC26N ist ein digitaler Audio-Prozessor fuumlr die Verwaltung von Audio-Systemen der fuumlr feste und mobile Installationen entwickelt wurde AC26N benutzt die modernste Technologie mit 2856 bit-Prozessoren und 24-bit-ADDA-Wandlern mit hoher Leistungsfaumlhigkeit Die verfuumlgbaren Funktionen des Prozessors sind Ein- und Ausgangsstufen Verzoumlgerung (delay) Polaritaumlt 12 Equalizer-Frequenzen fuumlr Ein- und Ausgangskanal viele Crossover-Wahlmoumlglichkeiten und Limiter mit hoher Leistung Die Filter-Kontrolle hat eine Aufloumlsung von 1 Hz Die Ein- und Ausgaumlnge koumlnnen mit unterschiedlichen Einstellungen geregelt werden um allen Anforderungen gerecht zu werden AC26N kann in Echtzeit kontrolliert werden und jeder Parameter kann am Frontpaneel und vom Computer mit intuitiver graphischer Schnittstelle mittels Software DVA Network zugaumlnglich und einer Netzverbindung RDnet oder uumlber USB eingestellt werdenDie SW-Aktualisierung fuumlr CPU und DSP uumlber PC erlaubt die Vorrichtung auf dem aktuellen Stand zu halten Man kann 32 vorgesehene Konfigurationen speichern und aufrufen
- AC26N - Bedienungsanleitung- Software-CD- Versorgungskabel
- 2 Ein- und 6 Ausgaumlnge mit flexibler Adressierung- Adressierbarer Stereo-Ein- und Ausgang AESEBU - DSP 2856-bit- AD-Wandler BURR BROWN 24-bit mit hoher Leistungsfaumlhigkeit- Aufloumlsungsfrequenz der Filter 1 Hz - 12 parametrische Equalizer fuumlr jeden Ein- und Ausgang- 2 Crossover-Filter fuumlr jeden Ausgang mit auswaumlhlbarer Neigung 122448dBoct- DRC Multikonfiguration mit hoher Leistungsfaumlhigkeit fuumlr die Konfiguration des
Limitersder Kompression jedes Ein- und Ausgangs- Einstellbare dB-Stufe Polaritaumlt und Verzoumlgerung (delay) fuumlr jeden Ein- und Ausgang- Firmware-Aktualisierung uumlber PC- Graphisches LCD-Display- 32 Voreinstellungen vom Benutzer einstellbar- USB-Schnittstelle fuumlr die Kontrolle und Konfiguration mit dem Computer- Schnittstelle RDnet welche erlaubt bis zu 256 fern liegende Vorrichtungen
zu kontrollieren
PC
PC
RDNET control(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FUNKTIONEN VORDERSEITE
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
BEDIENUNGEN UND FUNKTIONEN
1) DISPLAYDas graphische LCD-Display erlaubt die Informationen des AC26N ohne einen Computer zu benutzen anzuzeigen und zu editieren Der Kontrast kann im Hauptmenuuml eingestellt werden
2) DREHGRIFF Functions Selector UND Push EnterDiese Kontrolle erlaubt sich in den Menuumls auf dem Display zu bewegen und die Parameter auszuwaumlhlen und zu veraumlndernDrehung des Drehgriffes (Functions Selectors)- Man kann sich innerhalb der verschiedenen Menuumlseiten bewegen- Erlaubt die Veraumlnderung der ausgewaumlhlten ParameterDruck des Drehgriffes (Push Enter)- Erlaubt die AuswahlBestaumltigung der Parameter
3) Taste ldquoESCrdquo Diese Kontrolle erlaubt die angezeigten Menuumls zu verlassen oder zur vorherigen Anzeige zuruumlckzukehren
4) Taste ldquoMenuumlrdquo Diese Kontrolle erlaubt den direkten Zugang zum Hauptmenuuml
Deuts
chD
euts
chB
ed
ien
un
gsan
leit
un
gB
ed
ien
un
gsan
leit
un
g
29
Deuts
chD
euts
chB
ed
ien
un
gsan
leit
un
gB
ed
ien
un
gsan
leit
un
g
30
DVA USB Manager
Die Firmware des Verstaumlrkermoduls kann uumlber den USB-Anschluss aktualisiert werdenUm diesen Vorgang zu ermoumlglichen und zu vereinfachen wurde ein dediziertes Programm entwickelt das beim Hersteller angefordert und auf einen Computer installiert werden muss
Wir empfehlen die Software DVA USB Manager direkt von der Webseite dB Technologies (wwwdbtechnologiescom) im Abschnitt laquoSoftware amp Controllerraquo herunterzuladen
DVA Network
AC26N ist mit einer eigenen als RDNET bezeichneten Netzschnittstelle ausgestattet dank der es uumlber ein Interface (RDNET Control) an einen Computer angeschlossen werden koumlnnenHierzu wurde ein Kommunikationsprotokoll entwickelt mit dem die Daten empfangen und gesendet werden Dank dieser Verbindung koumlnnen die Lautsprecherparameter wie Ausgangsleistung Verstaumlrkertemperatur Limiterstatus usw in Echtzeit kontrolliert werden Auszligerdem koumlnnen verschiedene Entzerrungen ausgewaumlhlt bzw neue erstellt werden oder die gewuumlnschte Lautstaumlrke eingestellt werden
Wir empfehlen die Software DVA_Network direkt von der Webseite dB Technologies (wwwdbtechnologiescom) im Abschnitt laquoSoftware amp Controllerraquo herunterzuladenDOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
RUumlCKWANDANSCHLUumlSSE
1586 75 141210 11 13 169 17
14) USB-SteckverbinderDieser USB-Steckverbinder (Typ B) erlaubt den Prozessor an einem Computer anzuschlieszligen um die Firmware mit dem speziellen Programm (DVA Network) zu kontrollieren und zu aktualisieren
15) STROMANSCHLUSS MAINSErlaubt den Anschluss des mitgelieferten Versorgungskabels
16) SICHERUNGSTRAumlGER FUSEAufnahme fuumlr die Netz-Sicherung
17) HAUPTSCHALTER POWERDer Schalter erlaubt das Aus- und Einschalten des Audio-Controllers
BEDIENUNGEN UND FUNKTIONEN
5) WAHLSCHALTER -6dBDer Wahlschalter erlaubt das Level des analogen Eingangs XLR [6] um 6 dB zu verringern und gleichzeitig das hohe Ausgangslevel der Mixer oder anderer Audio-Vorrichtungen auszugleichen Wenn der Balken des Signallevels der Eingaumlnge auf dem Display [1] immer auf Maximum steht zeigt dies an dass das Signallevel am Eingang hoch ist und es wird empfohlen die Daumlmpfung -6dB zu benutzenIm Menuuml Option ist es moumlglich zu kontrollieren ob der Wahlschalter aktiviert ist
6) STECKVERBINDER AM EINGANG A UND BAuf Leitungslinie ausgeglichene EingaumlngeSie koumlnnen auch XLR-Steckdosen aufnehmen
7) AUSGANG-STECKVERBINDER ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo UND ldquo6rdquoAuf Leitungslinie ausgeglichene Ausgaumlnge Sie koumlnnen auch XLR-Stecker aufnehmen
Darauf achten dass die Ausgaumlnge korrekt entsprechend der Einstellungen der einzelnen Kanaumlle an den Lautsprechern oder Verstaumlrkern angeschlossen sind um Schaumlden und Fehlfunktionen vorzubeugen
Abschnitt ldquoAESEBUrdquo
8) EINGANGS-STECKVERBINDER INZusaumltzlich zu den analogen Audio-Eingaumlngen wurde ein digitaler Audio-Eingang SPDIF-AESEBU (AES3) vorgesehen der uumlber das Setup-Menuuml ausgewaumlhlt werden kannDer Eingang erfordert einen ausgeglichenen Anschluss mit einem XLR-Steckverbinder mit einem verdrillten Kabel mit 3 Leitern von 110 Ohm
9) AUSGANGS-STECKVERBINDER OUTDieser Steckverbinder erlaubt das Audiosignal an den analogen oder digitalen Eingaumlngen oder Ausgaumlngen zu verteilen Die Quelle muss uumlber das Menuuml Option eingestellt werdenDer Anschluss muss demselben Standard des Eingang entsprechen [Ref 8]
Abschnitt ldquoRDNETrdquo
10) EINGANGS-STECKVERBINDER DATA INPUTSteckverbinder RJ45 fuumlr den Dateneingang
11) AUSGANGS-STECKVERBINDER DATA LINKSteckverbinder RJ45 fuumlr den Datenausgang Fuumlr die serielle Kaskaden-Verbindung
12) LEUCHTANZEIGE ONDiese gruumlne Anzeige leuchtet nur wenn AC26N uumlber den Computer mit der Haupteinheit RDNET verbunden ist und diese erkannt hat
13) LEUCHTANZEIGE ACTIVEDiese gelbe Anzeige blinkt wenn eine Datenuumlbertragung zwischen RDNET und der Vorrichtung aktiv ist
PUSH
P SHU
SHPU
P SHU
PUSH
ANSCHLUumlSSE
Analoge Audio-AnschluumlsseDie ausgeglichenen Anschluumlsse erlauben die Geraumlusche der Kabel auf ein Minimum zu verringern und so die Benutzung langer Kabel zuzulassenDiese Anschluumlsse koumlnnen sowohl an den Ein- als auch an den Ausgaumlngen benutzt werdenDer XLR-Steckverbinder muss mit Pin 1 an Masse Pin 2 am Pluspol (+) und Pin 3 am Minuspol (-) angeschlossen werden Bei einem abgeschirmten Kabel muss die Abschirmung an Pin 1 liegenDie Verbindungskabel XLR-XLR und XLR-Jack 14 (63 mm) koumlnnen fuumlr den Anschluss
12
3
Eingang
XLR weiblichen
Pin 3 = MinuspolErkaumlltungphase -VE
Pin 3 = MinuspolErkaumlltungphase -VE
1 2
3
Ausgang
XLR maumlnnlichen
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Ring
Schaft
Spitze = PluspolWaumlrmephase +VE
Ring = MinuspolErkaumlltungphase -VE
Schaft=SchirmMasse
Spitze
Die nicht ausgeglichenen Anschluumlsse koumlnnen auch benutzt werden wenn die Kabelgeraumlusche ansteigen und diese Kabel duumlrfen nicht laumlnger sein als 5 MeterDiese Anschluumlsse koumlnnen sowohl an den Ein- als auch an den Ausgaumlngen benutzt werdenDie nicht ausgeglichenen Anschluumlsse koumlnnen das Signallevel am Eingang um 6 dB verringern um dem vorzubeugen muss Pin 3 an Masse angeschlossen werden obwohl dies das Geraumlusch verstaumlrken kann
12
3
Eingang
XLR weiblichen
1 2
3
Ausgang
XLR maumlnnlichen
Spitze Schaft
Spitze = Signal
Schaft=SchirmMasse
Pin 3 = zu Pin 1 gebruumlckt
Pin 3 = zu Pin 1 gebruumlckt
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
31
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
32
Digitales Audio (AESEBU)AESEBU (Protokoll AES3) ist ein ausgeglichener und uumlber einen Transformator elektrisch isolierter Eingang Er erlaubt die Benutzung von zwei Kanaumllen an einem einzigen abgeschirmten bipolaren Kabel Das gedrillte Kabel muss 3-polig sein eine Impedanz von 100 Ohm haben und mit einem XLR-Steckverbinder (AES3 Standard) abgeschirmt sein
RdnetJeder Port RDNet an Control 2 und Control 8 kann an max 32 kompatiblen Vorrichtungen die in Kaskade geschaltet sind angeschlossen werden Im nachstehenden Beispiel ist der Port der Kontrolleinheit RDNET CONTROL 2 am Eingang DATA INPUT eines AC 26N angeschlossen dessen paralleler Ausgang DATA LINK zum Eingang des naumlchsten AC26N geht Im Beispiel ist [n] eine Nummer zwischen 3 und 32 (maximale Anzahl der anschlieszligbaren Vorrichtungen an nur einem Netz)
RJ 45
|1|2|3|4|5|6|7|8|
Die Gesamtlaumlnge des Kabels CAT5 eines Unternetzes kann NICHT laumlnger als 900 Meter sein
Der Steckverbinder muss wie folgt angeschlossen sein1 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio +) 2 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio -)3 ndash Verfuumlgbar fuumlr andere Funktionen (zB analoge Masse)4 ndash digitale Masse5 ndash digitale Masse6 ndash Verfuumlgbar fuumlr andere Funktionen (zB Versorgung)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
EINSCHALTEN
Beim Einschalten der Vorrichtung startet die Initialisierung die einige Sekunden lang dauert Auf dem Display wird das Modell das Logo und der Fortschrittsbalken der Ladung des Programms angezeigt
Nach der Initialisierung erscheint auf dem Display das Menuumlfenster Meters Um die Angaben im Detail zu erfahren beziehen Sie sich bitte auf das Kapitel BESCHREIBUNG DES MENUumlFENSTERS Meters
AC26N kann jetzt benutzt werden
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
MENUrsquo PRINCIPALE
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Die sechs Menuumls im Prozessor zeigen undoder konfigurieren die Systemparameter
Anzeige der Levels der Ein- und Ausgaumlnge Anzeige des benutzten Programms und dessen Status Mute schnell
Speicherung Speicherung und Eliminierung der Systemkonfigurationen
Auswahl der Ausgaumlnge je nach Eingangssignal
Konfiguration jedes einzelnen Kanals
Konfiguration der Schnittfrequenzen und der Filtertypen fuumlr jeden einzelnen Ausgang
Zuordnung der Ein- und Ausgaumlnge Kontrast des Displays Firmware-Version Eingaumlnge und andere Optionen
Das Menuuml und die einzelnen Optionen der Anzeige koumlnnen durch Drehen des Drehgriffes FUNKTIONS SELECTOR ( ) ausgewaumlhlt werden
Die Hauptmenuumls sind
Meters
Preset
Matrix
Ch Job
X-Over
Option
Um die Auswahl zu treffen muss der gewuumlnschte Parameter auswaumlhlt und der Drehgriff Push Enter( | ) gedruumlckt werdenDas selbe Verfahren muss fuumlr die Auswahl undoder die Aumlnderung der Optionen innerhalb der Menuumlpunkte angewendet werden
BESCHREIBUNG DES MENUumlFENSTERS Meters
Diese Seite erlaubt die Konfigurationen und den allgemeinen Status der Ein- und Ausgaumlnge der benutzten Programmversion dessen Status und die Steuerung des Systems anzuzeigen
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
KONFIGURATION UND ANZEIGE
Um in das Fenster des Hauptmenuumls zu gelangen muss die Taste Menuuml ( ) auf der Frontseite der Vorrichtung gedruumlckt werdenMit der Taste ESC ( ) kehrt man von jeder Seite des Menuumls auf die vorherige Seite zuruumlck
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
33
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
34
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziertBei den digitalen Eingangssignalen entspricht die Angabe A und B dem EingangDreht man den Drehgriff FUNCTIONS SELECTOR [2] durchlaumluft man zyklisch die Ein- und Ausgangskanaumlle und die Angabe Mute allgemein (d) der ausgewaumlhlte Kanal wird hervorgehoben
b) BALKEN FUumlR DAS KOMPRESIONSLEVELMUTE KANAL
SIGNALKOMPRESSIONDie Signalkompression wird durch das Gleiten des rechten Balkens von oben nach unten angezeigt
MUTE Jeder einzelne Kanal kann auf Mute gestellt werden Den Kanal auswaumlhlen und den Drehgriff Push Enter [2] druumlcken um die Aumlnderung des Status zu bestaumltigen Die Angabe des Kanals wird durch den Buchstaben M ersetzt und der Balken wird komplett hervorgehobenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werden
c) BALKEN DES SIGNALLEVELSDie Anzeige des Levels jedes einzelnen Kanals wird durch das Gleiten des linken Balkens angezeigt
d) MUTE ALLGEMEINEs ist moumlglich alle Ein- und Ausgaumlnge gleichzeitig auf Mute zu schalten Den Drehgriff FUNCTIONS SELECTOR drehen den Buchstaben M waumlhlen und dann den Drehgriff Push Enter druumlckenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werdenDie allgemeine Stummschaltung hat eine houmlhere Prioritaumlt als die Stummschaltung der einzelnen Kanaumlle
e) ANSTEUERUNGSARTENEs wird angezeigt wie AC26N benutzt wird undoder an welchen Vorrichtungen es angeschlossen ist
= Benutzung stand-alone Kein Anschluss an einer externen Vorrichtung
= Direkt am Netz RDnet und am Computer angeschlossen
= Uumlber USB-Kabel direkt am Computer angeschlossen
f) ANZEIGE DES STATUS DER EINSTELLUNGENHier wird angezeigt ob einer oder mehrere Parameter des geladenen Programms im Vergleich zur letzten Speicherung veraumlndert wurden
Original-Programm
Programm mit veraumlnderten Parametern
g) EINGESTELLTES PROGRAMMDie Nummer zeigt das vom System geladene und benutzte Programm in Bezug auf die Lokalisierung der Speicherung an Fuumlr weitere Details beziehen Sie sich bitte auf das Menuuml Preset
Local
NET
USB
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
BESCHREIBUNG DES MENUumlFENSTERS Ch Job
Dieses Fenster erlaubt die Anzeige der Konfiguration jedes einzelnen Kanals
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) SIGNALLEVELZeigt die Signalstaumlrke an Das Ansteigen der Signalintensitaumlt wird in Dezibel (dB) ausgedruumlckt Der Parameter kann zwischen -8000 dB und +2000 dB in Schritten von 001 dB ausgewaumlhlt werden Ein Anstieg von 6 dB ist fast gleich eine Verdoppelung in linearer Skala des Spannungswertes des SignalsBei einer Staumlrke von 0 dB wird das Signal verstaumlrkt waumlhrend es ein einer Staumlrke von weniger als 0 dB abgeschwaumlcht wird
c) VERZOumlGERUNG DES SIGNALS (DELAY)Das wiedergegebene Audio-Signal kann verzoumlgert werden um die akustische Ausrichtung zu erlauben Dies gleicht die verschiedenen Positionen der Lautsprecher bei der Installation und Klangwiedergabe aus und wird in mS ausgedruumlckt Der Parameter kann zwischen 00 mS und 729 mS in Schritten von 01mS ausgewaumlhlt werden
Um ein Audiosignal auszurichten kann folgende Formel benutzt werden
Verzoumlgerung = GAPx1000)344
Verzoumlgerung = mS (in Millisekunden ausgedruumlckt)GAP = Abstand des Lautsprechers vom Referenzpunkt (in Metern ausgedruumlckt)Klanggeschwindigkeit = 344 ms
d) MUTEJeder einzelne Kanal kann auf Mute gestellt werden Derselbe Befehl kann im Fenster des Menuumls Meters aktiviert werden PS Die al lgemeine Stummschaltung hat eine houmlhere Priori taumlt als die Stummschaltung der einzelnen Kanaumlle
e) PHASEErlaubt die Phasenrotation um 180deg zum EingangssignalDiese Rotation erlaubt vor Allem die Optimierung der niederen Frequenzen bei komplexen Installationen
f) ENTZERRUNGENDieser Befehl oumlffnet das Menuumlfenster fuumlr die Entzerrung des einzelnen Kanals Er wird vor Allem benutzt um eine oder mehrere Frequenzen zu korrigieren die gedaumlmpft oder verstaumlrkt werden muumlssen
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
35
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
36
AC26N verwaltet 12 Filter fuumlr jeden einzelnen Ein- und Ausgangskanal mit drei verschiedenen Konfigurationen- Equalizer PEQ (peaking equalizer) ist ideal um nur ein bestimmtes Frequenzband
zu identifizieren zu isolieren und zu korrigieren Es gehen alle Frequenzen durch aber nur die um die mittlere Frequenz steigt und sinkt um eine bestimmte Bandbreite und eine bestimmte Staumlrke
- Equalizer High-Shelf geht alle Frequenzen durch aber die Frequenzen uumlber der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
- Equalizer Low-Shelf geht alle Frequenzen durch aber die Frequenzen unter der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
f Nummerierung der 12 verfuumlgbaren Filter fuumlr diesen Ein- oder Ausgang1
f2 Es wird der Filtertyp angezeigt
Dis Ausgeschaltet (nicht vorhanden)
PEQ Peaking equalizer
Sh H Filter High-Shelf
Sh L Filter Low-shelf
Beispiele PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
ANMERKUNGDer Parameter Bw legt das Frequenzfeld neben der eingestellten Frequenz fest wo der Filter aktiviert wird je houmlher der Bw-Wert desto houmlher das Frequenzfeld (1Bw=1 Oktave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filter High-Shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filter Low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) KOMPRESSIONDieser Befehl oumlffnet das Menuumlfenster fuumlr die Kompression des einzelnen Kanals
g1) TresholdIdentifiziert die Schwelle an der das Kompressionsverhaumlltnis beginnt Der Basiswert 11
g2) RatioIdentifiziert das Kompressionsverhaumlltnis zwischen dem Ein- und Ausgangssignal
g3) Post Gain Attach Release HoldDiese Daten entsprechen dem Kompressionsverhaumlltnis das man erreichen moumlchte
Post Gain ist der Gewinn am AusgangAttack ist die Anschlusszeit Release ist die ReleasezeitHold ist die Beibehaltungszeit
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
BESCHREIBUNG DES MENUumlFENSTERS Preset
Dieses Fenster erlaubt bis zu 32 Konfigurationen im AC26N zu speichernDer Hersteller liefert das System mit einem voreingestellten Programm das auf Position 0 gespeichert ist und nicht uumlberschrieben werden kann
032 Es zeigt die Lokalisierung der Speicherung der KonfigurationDiese Nummer erscheint auch im Fenster Meters auf der Position (g) Das benutzte Programm kann jederzeit vom Benutzer angezeigt werden
Empty Preset Es ist der Name der der Nummer der Lokalisierung zugeordnet wird wenn keine Einstellung gespeichert ist (leer)
Local preset Es i s t de r Name de r de r Nummer de r Loka l i s i e rung zugeordnet wird wenn eine Konfiguration gespeichert wird
ANMERKUNG = Man kann eine Einstellung mit dem gewuumlnschten Namen mit max 16 Buchstaben nur speichern wenn man die Schnittstelle uumlber den Computer benutzt
Bei der Wahl eines Programms erscheint folgendes Fenster
Anzeige des Namens der dem Programm zugeordnet istUm auf die Anwendung einzuwirken stehen 3 Auswahlmoumlglichkeiten zur Verfuumlgung
Das Programm wird im Speicher des AC 26N gespeichert
Das Programm wird geloumlscht
Das Programm wird geladen und ist bereit fuumlr die Benutzung
Save
Del
Load
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
37
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
38
BESCHREIBUNG DES MENUumlFENSTERS X-Over
Dieses Fenster erlaubt fuumlr jeden Ausgang einen Bassdurchgangsfilter einen Hochdurchgangsfilter oder mittels Kombination von beiden einen Banduumlbergangsfilter zu waumlhlenDer Filter ist ein Linkwitz-Riley wo man die Neigung von 12 dBoct 24dBoct oder 48 dBoct und die entsprechende Schnittfrequenz auswaumlhlen kann
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) AUSGANGSKANAumlLE
Die Steckverbinder am Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) FILTER CROSSOVERDen Filter nach Bedarf waumlhlen Man kann folgendes auswaumlhlen
Dis Kein Filter aktiviert
HP Hochdurchgangsfilter nur den Teil des Audiosignals durchlassen der uumlber der Schnittfrequenz liegt
LP Bassdurchgangsfilter nur den Teil des Audiosignals durchlassen der unter der Schnittfrequenz liegt
Filter-Konfiguration Tiefpass Hochpass
Nichts Dis Dis
Hochpass HP Dis
Tiefpass Dis LP
Bandpass HP LP
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
c) DAumlMPFUNGSNEIGUNGDie Daumlmpfungsneigung des Audiosignals auf der Basis der Verringerung auswaumlhlen die man erreichen moumlchte Je houmlher die Daumlmpfungsneigung bei gleicher Schnittfrequenz desto groumlszliger ist die Signalauswahl Man kann folgendes waumlhlen
12 entsprechend 12 dboct
24 entsprechend 24 dboct
48 entsprechend 48 dboct
d) SCHNITTFREQUENZErlaubt die Durchgangsfrequenz der niederen Frequenzen (Bassdurchgangsfilter) oder der hohen Frequenzen (Hochdruchgangsfilter) einzustellenDie Auswahl des Schnitts bezieht sich auf die Wiedergabe die man erreichen moumlchteDie benutzte Maszligeinheit ist Hz
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
BESCHREIBUNG DES MENUumlFENSTERS Matrix
Erlaubt fuumlr jeden Ausgang das Eingangssignal zu waumlhlen das als Quelle benutzt werden soll
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) AUSGANGSKANAumlLEIdentifizierung des einzustellenden Ausgangskanals
b) IDENTIFIZIERUNG DER EINGAumlNGEDen Signaltyp auswaumlhlen der nach eigener Anforderung jedem einzelnen Ausgang zugeordnet werden soll Man kann folgendes waumlhlen
In A Das Signal wird dem Eingang A zugeordnet
In B Das Signal wird dem Eingang B zugeordnet
In A+B Zuordnung der a lgebra ischen Summe der be iden Eingangssignale A und B
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
BESCHREIBUNG DES MENUumlFENSTERS Option
Erlaubt die Anzeige der Systemeinstellungen wie die Zuordnung der Ein- und Ausgaumlnge Daumlmpfung Displaykontrast und Firmware-Version
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B Src
Diese Option erlaubt die Einstellung des Audio-Signaltyps am Eingang
Analoge Audiosignale (Eingaumlnge A und B)
Digitale Audiosignale (Eingang AESEBU)
DigOut Src
An In =Audiosignale an den analogen Eingaumlngen
Dig In =Audiosignale am digitalen Eingang
OUT 1-2 =Audiosignale an den Ausgaumlngen 1 und 2
OUT 3-4 =Audiosignale an den Ausgaumlngen 3 und 4
OUT 5-6 =Audiosignale an den Ausgaumlngen 5 und 6
Input Mode
An In
Dig In
Indip =
Linked =
Diese Option erlaubt die Audioquelle zu waumlhlen die fuumlr den Steckverbinder AESEBU OUT (digitaler Ausgang) bestimmt ist
Erlaubt die Eingaumlnge zu konfigurieren
Sie sind unabhaumlngig und selbststaumlndig sie unterliegen keinen Verpflichtungen untereinander Sie sind verbunden und funktionieren im Stereo-Modus
Die Kompressoren Filter Verzoumlgerungen die Lautstaumlrke sind bei beiden Kanaumllen identisch
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
39
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
40
Atten PadZeigt an wie der Wahlschalter -6 dB auf der Ruumlckseite eingestellt ist [Ref 5] Dieser Wahlschalter muss aktiviert werden wenn das Level an den analogen Eingaumlngen zu hoch ist Der Wahlschalter wird uumlber die Taste aktiviert im Menuuml gibt es nur eine Anzeige
0dB = Wahlschalter nicht aktiviert
-6dB = Wahlschalter aktiviert
Contrast
10 heller 60 dunkler 100
Fw Vers
Die Eingangssignale sind dieselben wie die Eingangsquelle
Die Eingangssignale werden vom internen Prozessor um -6 dB gedaumlmpft
Erlaubt den Kontrast des LCD-Displays einzustellen um den Unterschied der Helligkeit auf den Installationsort auszurichten Ein deutlicheres Display erlaubt auf korrekte und schnelle Weise innerhalb der Menuumls zu surfenDie Hersteller-Einstellung am Ausgang liegt bei 60
Zeigt die Firmware-Version des Prozessors an
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
41
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
42
TECHNISCHE DATEN
Antwort in FrequenzDynamische GammaCMMRCrosstalkDistorsion
ProzessorFrequenz der DatenausarbeitungAnaloge Converter Verzoumlgerung der VerteilungSpeicherung der Konfigurationen
DisplayTastenBedienungen
Analoger Eingang ndeg2 x XLR (3-poliger Female Stecker)Impedanz des Eingangs gt10KOhmMaximales Level +21dBu ohne PAD
+27dBu bei PAD
Impedanz des Ausgangs 50OhmMaximales Level +21dBu Typ symmetrisch
Typ SPDIF-AESEBU (AES3)
Typ Entsprechend dem Standard des Eingang
Typ
Typ
NETZSPANNUNGABMESSUNGEN (BXHXT)GEWICHT
AUDIO-LEISTUNGEN+- 01dB (20 to 30kHz)116dB typgt 60dB (50 to 10kHz)lt -100dB0002 (1kHz +4dBu)
DIGITALE AUDIO-LEISTUNGEN DSP 2856-bit 48KHz24-bit BURR BROWN15ms32 preset
KONTROLLEN LCD GrafikESC - MENU - FUNCTIONS SELECTIONENTER
EIN-AUSGAumlNGE
Analoger Ausgang ndeg6 x XLR (3-poliger Male Stecker)
Digitaler Eingang ndeg1x XLR (3-poliger female Stecker)
Digitaler Ausgang ndeg1x XLR (3-poliger Male Stecker)
Ein-Ausgang Rdnet ndeg2 x XLR RJ45 (kabel CAT 5) USB Typ B
KONTROLLPARAMETER AUDIOStaumlrke -80dB a +20dB step 01dBVerzoumlgerung Eingang 0 a 729mS step 01 mS
Ausgang 0 a 340mS step 01mSPhasenrotation 0deg - 180deg
KOMPRESSIONSchwelle -80dB a +20dB step 01dBVerhaumlltnis 11 a Inf1 step 001Staumlrke am Ausgang 0dB a 40dB step 01dBAnschlusszeit 1mS a 1000mS step 01mSReleasezeit 1mS a 1000mS step 01mSBeibehaltungszeit 1mS a 1000mS step 01mS
EQUALIZER12 Equalizer fuumlr jeden Ein- und Ausgang
PEQ (parametrischer) Hi-shelf Lo-sheftFrequenz 20Hz a 20KHz step 1HzStaumlrke -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (lediglich PEQ)
FILTER CROSSOVERFilter Linkwitz Riley
HP HochdurchgangsfilterLP Bassdurchgangsfilter
Neigung 12dBoct - 24dBoct - 48dBoctSchnittfrequenz 5Hz a 20KHz step 1Hz
Full-range 100-240Vac 50-60Hz430482x43x130mm 19Kg
AnmerkungenSpezifikationen unterliegen Aumlnderungen ohne Vorankuumlndigung
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
INTRODUCTIONAC26N est un processeur audio numeacuterique pour la gestion de leacutequipement audio conccedilu pour des installations fixes et mobiles Il fonctionne selon une technologie de pointe avec des processeurs agrave 2856bits et des convertisseurs ADDA agrave 24-bits hautes performances Les fonctions du processeur sont les niveaux dentreacutee et de sortie le deacutelai (delay) la polariteacute 12 bandes deacutegalisation par canal dentreacutee et de sortie diffeacuterentes seacutelections de croisement (crossover) et un limiteur hautes performances Le controcircle des filtres a une reacutesolution de 1Hz Les entreacutees et les sorties peuvent ecirctre programmeacutees en plusieurs configurations pour satisfaire tous les besoins AC26N peut ecirctre controcircleacute en temps reacuteel et tous les paramegravetres peuvent ecirctre configureacutes depuis le pupitre frontale et par ordinateur avec interface graphique intuitive accessible via le logiciel laquoDVA Networkraquo et une connexion de reacuteseau deacutedieacutee RDnet ou USBLa mise agrave jour du logiciel pour lUniteacute centrale et DSP par ordinateur portable permet de maintenir le dispositif actualiseacute Il est possible denregistrer et de rappeler 32 configurations preacute-eacutequipeacutees de configuration
Contenu de lemballage - AC26N - Mode demploi- CD logiciel- Cacircble dalimentation
Caracteacuteristiques- 2 entreacutees et 6 sorties avec adressage flexible- Entreacutee et sortie steacutereacuteo AESEBU adressables - DSP 2856-bit- Convertisseurs AD BURR BWOWN 24-bit hautes performances- Freacutequence de reacutesolution des filtres 1 Hz - 12 eacutegaliseurs parameacutetriques pour chaque entreacutee et sortie- 2 filtres de croisement par sortie avec pente seacutelectionnable agrave 122448dBoct- DRC agrave configuration multiple hautes performances pour configuration limiteur
compression pour chaque entreacutee et sortie- Niveau reacuteglable en dB polariteacute et deacutelai pour chaque entreacutee et sortie- Mise agrave jour du micrologiciel par lordinateur- Affichage graphique agrave cristaux liquides- 32 preacutereacuteglages enregistrables par lutilisateur- Interface USB pour le controcircle et la configuration par ordinateur- Interface RDnet permettant de controcircler jusquagrave 256 dispositifs agrave distance
PC
PC
RDNETcontrol(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FONCTIONS DE LA FACE AVANT
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
COMMANDES ET FONCTIONS1) AFFICHAGE
Laffichage graphique agrave cristaux liquides permet de visualiser et deacutediter les informations de lAC26N sans utiliser lordinateur Le contraste peut ecirctre configureacute dans le menu principal
2) MANETTE Functions Selector et Push EnterCe controcircle permet de se deacuteplacer de seacutelectionner et de modifier les paramegravetres dans les menus affichables agrave leacutecranRotation de la manette (Functions Selectors)- permet de se deacuteplacer sur les diffeacuterentes pages du menu - permet de modifier les paramegravetres seacutelectionneacutesPression de la manette (Push Enter)- permet de seacutelectionnervalider les paramegravetres
3) Bouton ESC Ce controcircle permet de quitter les menus afficheacutes ou de revenir agrave la visualisation preacuteceacutedente
4) Bouton Menu Ce controcircle permet dacceacuteder directement au menu principal
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
Fra
nccedilais
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
43
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
Fra
nccedilais
44
DVA Network
AC26N est eacutequipeacute dune interface de reacuteseau proprieacutetaire deacutenommeacutee RDNET au moyen de laquelle il est possible de sinterfacer agrave lordinateur agrave travers un peacuteripheacuterique (RDNET control)
Pour cela un protocole de communication a eacuteteacute deacuteveloppeacute avec lequel il est possible de recevoir et denvoyer les donneacutees ce branchement permet de faire le monitorage en temps reacuteel des paramegravetres du diffuseur comme puissance de sortie tempeacuterature de lamplificateur eacutetat du limiteur etc Il est aussi possible de seacutelectionner diffeacuterentes eacutegalisations ou den creacuteer de nouvelles et de reacutegler les niveaux de volume souhaiteacutes au moyen dun plug-in approprieacute
On conseille de teacuteleacutecharger gratuitement le logiciel DVA Network directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
DVA USB Manager
On conseille de teacuteleacutecharger gratuitement le logiciel DVA USB Manager directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
Le micrologiciel du module amplificateur peut ecirctre remis agrave jour par le port USBPour rendre cette mise agrave jour possible et facile un programme speacutecifique a eacuteteacute deacuteveloppeacute
DOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
CONNEXIONS DU PANNEAU ARRIEgraveRE
1586 75 141210 11 13 169 17
14) Connecteur ldquo USBrdquoCe connecteur USB (type B) permet de connecter le processeur agrave un ordinateur pour le controcircle et la mise agrave jour du micrologiciel via un programme deacutedieacute (DVA Network)
15) PRISE DALIMENTATION MAINSPermet la connexion du cacircble dalimentation fourni de seacuterie
16) PORTE-FUSIBLE FUSELogement pour fusible de ligne
17) INTERRUPTEUR GENERAL POWERLinterrupteur permet de mettre en marche ou deacuteteindre le controcircleur audio
COMMANDES ET FONCTIONS
5) SELECTEUR ldquo-6dBrdquoLe seacutelecteur permet de reacuteduire de 6dB les niveaux dentreacutee analogiques XLR [6] tout en compensant les niveaux eacuteleveacutes de sortie des meacutelangeurs ou dautres dispositifs audio Quand la barre du niveau de signal des entreacutees sur laffichage [1] reste au maximum cela indique que le niveau du signal entrant est eacuteleveacute Il est alors conseilleacute dutiliser latteacutenuation -6dBIl est possible de veacuterifier quand le seacutelecteur est activeacute par le menu Option
6) CONNECTEURS DENTREE ldquoArdquo ET ldquoBrdquoEntreacutees eacutequilibreacutees au niveau de la ligneIls sont en mesure daccepter des connecteurs XLR macircles
7) CONNECTEURS DE SORTIE ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo ET ldquo6rdquoSorties eacutequilibreacutees au niveau de la ligne Ils sont en mesure daccepter des connecteurs XLR femelles
Prendre garde agrave brancher convenablement les sorties sur les diffuseurs ou les amplificateurs en fonction des configurations de chaque canal pour eacuteviter des deacutegacircts et des problegravemes de fonctionnement
Section ldquoAESEBUrdquo
8) CONNECTEUR DENTREE INOutre les entreacutees audio analogiques une entreacutee audio numeacuterique SPDIF-AESEBU (AES3) a eacuteteacute preacutevue et peut ecirctre seacutelectionneacutee par le menu de setupLentreacutee requiert une connexion eacutequilibreacutee en utilisant un connecteur XLR avec un cacircble agrave 3 conducteurs de 110ohm torsadeacute
9) CONNECTEUR DE SORTIE OUTCe connecteur permet de relancer le signal audio dans les entreacutees analogiques ou numeacuteriques ou sur les sorties La source doit ecirctre reacutegleacutee par le menu OptionLa connexion sera conforme agrave la mecircme norme que lentreacutee [reacutef8]
Section ldquoRDNETrdquo
10) CONNECTEUR DENTREE DATA INPUTConnecteur RJ45 entreacutee de donneacutees
11) CONNECTEUR DE SORTIE DATA LINKConnecteur RJ45 sortie de donneacutees pour la connexion de seacuterie en cascade
12) VOYANT LUMINEUX ONCe voyant de couleur verte sallume uniquement quand lAC26N a reconnu et est connecteacute agrave luniteacute principale RDNET par lordinateur
13) VOYANT LUMINEUX ACTIVECe voyant de couleur jaune clignote quand une transmission des donneacutees est active entre RDNET et le dispositif
PUSH
P SHU
SHPU
P SHU
PUSH
CONNEXIONS
Audio analogiquesLes connexions eacutequilibreacutees permettent de reacuteduire au minimum le bruit provoqueacute par les cacircbles et dutiliser de longs cacircblesCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLe connecteur XLR doit ecirctre brancheacute avec la broche 1 agrave la masse la broche 2 au chaud (+) et la broche 3 au froid (-) En cas de cacircble blindeacute brancher le blindage agrave la broche 1Les cacircbles de connexion XLR-XLR et XLR-Jack14(63mm) peuvent semployer pour la connexion agrave lAC26N
12
3
Entreacutee
Entreacutee
XLR - femme
XLR - femme
1 2
3
Sortie
Sortie
XLR - Macircle
XLR - Macircle
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2 = Point chaudPhase +VE
Broche 3 =Point froidPhase -VE
Broche 3 =Point froidPhase -VE
Anneau
Manchon
Pointe Point chaudPhase +VE
Anneau = Point froidPhase -VE
ManchonB Masselindeacute
Pointe
Les connexions deacuteseacutequilibreacutees peuvent semployer mecircme si le bruit provoqueacute par les cacircbles augmente Les cacircbles ne peuvent deacutepasser 5m de longCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLes connexions deacuteseacutequilibreacutees peuvent abaisser le niveau du signal entrant de 6dB Pour remeacutedier agrave cet inconveacutenient il faut brancher la broche 3 agrave la masse mecircme si cela augmente le bruit
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
45
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
46
12
3
1 2
3
Pointe Manchon
Pointe = Signal
Broche 3 = Link to Pin 1
Broche 3 = Link to Pin 1
ManchonB Masselindeacute
Audio numeacuteriques (AESEBU)
AESEBU (protocole AES3) est une entreacutee eacutequilibreacutee isoleacutee eacutelectriquement agrave laide dun transformateur Elle permet demployer deux canaux audio dans un seul cacircble bipolaire blindeacute Les caracteacuteristiques du cacircble doivent ecirctre de 3 pocircles impeacutedance 100ohm torsadeacute et blindeacute avec connecteur XLR (AES3 standard)
RJ 45
|1|2|3|4|5|6|7|8|
RDnet
Chaque port RDNet des Control 2 et Control 8 peut ecirctre brancheacute agrave un maximum de 32 dispositifs compatibles placeacutes en cascade Dans lexemple suivant le port de luniteacute de controcircle RDNET CONTROL 2 est relieacute agrave lentreacutee DATA INPUT dun AC26N dont la sortie parallegravele DATA LINK est envoyeacutee agrave lentreacutee de lAC26N successif Dans lexemple [n] est un nombre compris entre 3 et 32 (limite maximale des dispositifs que lon peut relier agrave un sous-reacuteseau)
La longueur totale du cacircble CAT5 dun sous-reacuteseau NE peut PAS deacutepasser 900 megravetres
Le connecteur doit ecirctre relieacute comme 1 ndash disponible pour dautres fonctions (par exemple audio +) 2 ndash disponible pour dautres fonctions (par exemple audio )3 ndash disponible pour dautres fonctions (par exemple masse analogique)4 ndash masse numeacuterique5 ndash masse numeacuterique6 ndash disponible pour dautres fonctions (par exemple alimentation)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
MISE EN MARCHE
Lors de la mise en marche du dispositif linitialisation deacutebute et dure quelques secondes Leacutecran affiche le modegravele le logo et la barre de progression du chargement du programme
En fin de processus dinstallation leacutecran affiche la fenecirctre du menu Meters Pour connaicirctre les indications en deacutetail consulter le paragraphe DESCRIPTION FENETRE MENU Meters
LAC26N est precirct agrave lemploi
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION ET VISUALISATION
Pour entrer dans la fenecirctre du menu principal il faut pousser sur la touche MENU ( ) agrave lavant du dispositifDune page quelconque du menu en poussant sur la touche ESCrdquo ( ) on revient automatiquement sur la page-eacutecran preacuteceacutedente
MENU PRINCIPAL
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Le processeur contient six menus Ils montrent etou configurent les paramegravetres du systegravemeLes menus principaux sont
Meters Visualisation des niveaux des entreacutees et des sorties visualisation du programme utiliseacute et eacutetat mute rapide
Preset Meacutemoriser enregistrer et eacuteliminer les configurations du systegraveme
Matrix seacutelectionner les sorties en fonction du signal entrant
Ch Job configuration de chaque signal
X-Over configurer les freacutequences de coupure et les types de filtres pour chaque sortie
Option attribution des entreacutees et des sorties contraste daffichage la version du micrologiciel les entreacutees et dautres options
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
47
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
48
DESCRIPTION DE LA FENETRE MENU Metersrdquo
Cette fenecirctre permet de visualiser les configurations et leacutetat geacuteneacuteral des entreacutees et des sorties la version du programme utiliseacute son eacutetat et le mode de pilotage du systegraveme
Les menus et les options afficheacutees peuvent se seacutelectionner en tournant la manette ldquoFUNCTIONS SETECTORrdquo ( ) Pour avoir accegraves agrave linteacuterieur de la seacutelection il faut mettre le paramegravetre souhaiteacute en eacutevidence et pousser sur la manette ldquoPush Enterrdquo ( | ) Il faut en faire de mecircme pour seacutelectionner etou modifier les options dans les commandes du menu
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositifAvec des signaux dentreacutee numeacuteriques les indications ldquoArdquo et ldquoBrdquo correspondent agrave lentreacuteeEn tournant la manette ldquoFUNCTIONS SELECTORrdquo [2] on fait deacutefiler en mode cyclique les canaux dentreacutee de sortie et lindication de mute geacuteneacuteral (d) le canal seacutelectionneacute est mis en eacutevidence
b) BARRE DE NIVEAU DE COMPRESSIONMUTE CANAL
COMPRESSION DE SIGNALLa compression du signal est visualiseacutee par le deacutefilement de la barre de droite de haut en bas
MUTE Chaque canal peut ecirctre placeacute en mute Seacutelectionner le canal et pousser sur la manette ldquoPush Enterrdquo [2] pour valider le changement deacutetat Lindication du canal sera remplaceacutee par la lettre M et la barre sera totalement mise en eacutevidencePour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterations
c) BARRE DE NIVEAU DE SIGNALLindication du niveau de chaque canal est signaleacutee par le deacutefilement de la barre de gauche
d) MUTE GENERALIl est possible de mettre simultaneacutement toutes les entreacutees et les sorties en mute Tourner la manette ldquoFUNCTIONS SELECTORrdquo seacutelectionner la lettre M et pousser sur la manette Push EnterPour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterationsLe mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) MODES DE COMMANDEIl affiche le mode dutilisation etou les dispositifs qui sont relieacutes agrave lAC26N
Local = utilisation autonome Aucune connexion agrave un dispositif exteacuterieur
NET = relieacute directement au reacuteseau deacutedieacute RDNet et agrave lordinateur
USB = relieacute directement agrave un ordinateur par cacircble USB
f) INDICATION DETAT DE PARAMETRAGECette indication permet de constater si un ou plusieurs paramegravetre(s) du programme chargeacute aont eacuteteacute modifieacute(s) par rapport au dernier sauvetage
= programme dorigine
= programme avec des paramegravetres modifieacutes
g) PROGRAMME CONFIGURELe chiffre indique le programme chargeacute et utiliseacute par le systegraveme agrave lemplacement de sauvetage Consulter le menu de Preset pour de plus amples deacutetails
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
DESCRIPTION DE LA FENETRE MENU Ch Job
Cette fenecirctre permet dafficher la configuration de chaque canal
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) NIVEAU DU SIGNALIndique le gain du signal Laugmentation de lintensiteacute dun signal est libelleacutee en deacutecibel (dB) Le paramegravetre peut ecirctre seacutelectionneacute de -8000dB agrave +2000dB avec des pas de 001dB Une augmentation de 6dB est eacutegale approximativement au redoublement agrave leacutechelle lineacuteaire du niveau du signal sous tensionAvec un gain supeacuterieur agrave 0dB le signal est amplifieacute tandis quavec un gain infeacuterieur agrave 0dB le signal est atteacutenueacute
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
49
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
50
c) DELAI DU SIGNAL (DELAY)Le signal audio reproduit peut ecirctre retardeacute pour permettre lalignement acoustique Cela compense les diffeacuterentes positions des diffuseurs pendant linstallation et la reproduction sonore Il se libelle en mS Le paramegravetre peut ecirctre seacutelectionneacute de 00mS agrave 729mS avec un pas de 01mSPour aligner un signal audio il est possible dutiliser la formule suivante
Deacutelai = (GAPx1000)344
Deacutelai = ms (en millisecondes)GAP = distance du diffuseur du point de reacutefeacuterence (en megravetres)Vitesse du son = 344ms
d) MUTEChaque canal peut ecirctre placeacute en mute La mecircme commande peut ecirctre activeacutee dans la fenecirctre du menu meters NB Le mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) PhasePermet la rotation de phase de 180deg par rapport au signal entrantCette rotation permet loptimisation surtout des basses freacutequences dans les installations complexes
f) EGALISATIONCette commande ouvre la fenecirctre du menu deacutegalisation de chaque canal Elle sert surtout pour corriger une ou plusieurs freacutequences qui doivent ecirctre atteacutenueacutees ou augmenteacutees
M M
LAC26N gegravere 12 filtres par canal dentreacutee et sortie avec trois types de configurations diffeacuterentes - Leacutegaliseur PEQ (peaking equalizer) est ideacuteal pour identifier isoler et
corriger une seule plage de freacutequences bien deacutetermineacutee Toutes les freacutequences passent mais il augmente ou diminue uniquement celles autour de la freacutequence centrale pour une bande preacutecise et un gain deacutefini
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessus de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessous de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
f Numeacuterotation des 12 filtres disponibles pour cette entreacutee ou cette sortie1
f Le type de filtre est afficheacute 2
Dis Deacutesactiveacute (absent)
PEQ Peaking equlizer
Sh H Filtre high-shelf
Sh L Filtre high-shelf
Exemples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
REMARQUELe paramegravetre Bw deacutetermine le champ de freacutequences adjacent agrave la freacutequence configureacutee ougrave est activeacute le filtre Plus la valeur Bw est eacuteleveacutee plus vaste est le champ de freacutequences (1Bw=1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONCette commande ouvre la fenecirctre du menu de compression de chaque canal
g1) TresholdIdentifie le seuil ougrave commence le rapport de compression La valeur de base 11
g2) RatioIndique le rapport de conversion entre le signal entrant et le signal sortant
g3) Post Gain Attach Release HoldCes donneacutees deacutependent du rapport de conversion que lon veut obtenir - Post Gain est le gain de sortie- Attack est le temps dattaque - Release est le temps de relacircchement- Hold est le temps de maintien
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
52
DESCRIPTION DE LA FENETRE MENU Preset
Cette fenecirctre permet de meacutemoriser jusquagrave 32 configurations dans lAC26NLe fabricant fournit le systegraveme avec un programme configureacute et enregistreacute en position 0 et non susceptible deacutecrasement
032 Elle indique lemplacement de sauvetage de la configurationCe numeacutero apparaicirct dans la fenecirctre Meters en position (g) A tout moment le programme utiliseacute peut ecirctre afficheacute par lutilisateur
Empty Preset Cest le nom qui est associeacute au numeacutero de lemplacement quand aucune configuration (vide) nest enregistreacutee
Local preset Local preset est le nom qui est associeacute au numeacutero de lemplacement quand on enregistre une configuration NB = Il est possible denregistrer une configuration avec lenom souhaiteacute de 16 lettres tout au plus agrave condition que lonutilise linterface via lordinateur
Le nom du programme assigneacute est indiqueacutePour toucher agrave lapplication 3 choix soffrent agrave vous
Save Le programme est enregistreacute en meacutemoire de lAC26N
Del Le programme est effaceacute
Load Le programme est chargeacute et precirct agrave lemploi
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
51
DESCRIPTION DE LA FENETRE MENU X-Over
Cette fenecirctre permet de seacutelectionner un filtre passe bas un filtre passe haut ou par la combinaison des deux de creacuteer un filtre passe bande pour chaque sortieLe filtre actif est un Linkwitz-Riley qui permet de seacutelectionner la pente de 12dBoct 24dBoct ou 48dBoct et sa freacutequence de coupure
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) CANAUX DE SORTIE
Les connecteurs de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) FILTRE CROSSOVERSeacutelectionner le filtre selon les besoins Il est possible de seacutelectionner
Dis Aucun filtre activeacute
HP Filtre passe-haut laisse passer uniquement la partie de signal audio supeacuterieure agrave la freacutequence de coupure
LP Filtre passe-bas laisse passer uniquement la partie de signal audio infeacuterieure agrave la freacutequence de coupure
Configuration du filtre Passe-haut Passe-bas
Rien Dis Dis
Passe-haut HP Dis
Passe-bas Dis LP
Passe-bande HP LP
12dBoct
24dBoct
Hz
dB
Ga
in 48dBoct
12dBoct
24dBoct
Hz
dB
Ga
in
48dBoct
c) PENTE DATTENUATIONSeacutelectionner la pente datteacutenuation du signal audio en fonction de la diminution que lon veut obtenir Plus la pente datteacutenuation est eacuteleveacutee agrave eacutegaliteacute de freacutequence de coupure plus eacuteleveacutee sera la seacutelection du signal Il est possible de seacutelectionner
12 correspond agrave 12dboct
24 correspond agrave 24dboct
48 correspond agrave 48dboct
d) FREQUENCE DE COUPUREElle permet de reacutegler la freacutequence de passage des freacutequences infeacuterieures (filtre passe-bas) ou des freacutequences supeacuterieures (filtre passe-haut) uniquementLe choix de la coupure deacutepend de la reproduction que lon veut obtenirLuniteacute de mesure utiliseacutee est lHz
Hz
Hz
dB
dB
Ga
in
f0
f0
0dB0dB
0dB
-6dB
freacutequence
freacutequence
freacutequence
freacutequence
Ga
in
f0
0dB
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
53
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
54
DESCRIPTION DE LA FENETRE MENU Matrix
Elle permet de seacutelectionner le signal entrant agrave utiliser comme source pour chaque sortie
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) CANAUX DE SORTIEIdentification du canal sortant agrave reacutegler
b) IDENTIFICATIONS DES ENTREESSeacutelectionner le type de signal agrave associer agrave chaque sortie en fonction des besoins Il est possible de seacutelectionner
In A Le signal entrant A est associeacute
In B Le signal entrant B est associeacute
In A+B La somme algeacutebrique des deux signaux entrants A et B est associeacutee
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
DESCRIPTION DE LA FENETRE MENU Option
Permet dafficher les reacuteglages du systegraveme comme lassignation des entreacutees et des sorties latteacutenuation le contraste de laffichage et la version du logiciel
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcCette option permet de reacutegler le type de signal audio entrant
An In =signaux audio analogiques (entreacutees ldquoArdquo et ldquoBrdquo)
Dig In =signaux audio numeacuteriques (entreacutee AESEBU)
DigOut SrcCette option permet de seacutelectionner la source audio qui sera adresseacutee sur le connecteur AESEBU OUT (sortie numeacuterique)
An In = signaux audio des entreacutees analogiques
Dig In =signaux audio sur lentreacutee numeacuterique
OUT 1-2 = signaux audio sur les sorties 1 et 2
OUT 3-4 = signaux audio sur les sorties 3 et 4
OUT 5-6 = signaux audio sur les sorties 5 et 6
Input ModePermet de configurer les entreacutees
Indip = sont indeacutependantes et autonomes Ne sont soumises agrave aucun type de lien
Linked = sont unies et fonctionnent en mode steacutereacuteo Les compresseurs les filtres les deacutelais le volume sont identiques pour les deux canaux
Atten PadIndique le mode de reacuteglage du seacutelecteur ldquo-6dBrdquo placeacute agrave larriegravere [reacutef 5] Il faut activer ce seacutelecteur quand les niveaux dentreacutee analogiques sont trop eacuteleveacutes Le seacutelecteur sactive uniquement par le bouton Dans le menu il sagit dune simple visualisation
0dB = seacutelecteur non activeacute Les signaux dentreacutee sont identiques agrave la source entrante
-6dB = seacutelecteur activeacute Les signaux entrants sont atteacutenueacutes de -6dB par le processeur interne
ContrastIl permet de reacutegler le contraste de laffichage agrave cristaux liquides pour compenser la diffeacuterence de luminositeacute avec le lieu dinstallation Une plus grande clarteacute de laffichage permet de naviguer convenablement et rapidement dans les menusLe reacuteglage agrave la sortie de lusine du fabricant est de 60
10 plus clair 60 plus fonceacute 100
Fw VersIndique la version du logiciel du processeur
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
55
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
56
DONNES TECHINIQUES
PERFORMANCES AUDIOReacuteponse en freacutequence +- 01dB (20 to 30kHz)Plage dynamique 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsion 0002 (1kHz +4dBu)
PERFORMANCES AUDIO NUMERIQUES Processeur DSP 2856-bit Freacutequence de traitement des donneacutees 48KHzConvertisseurs analogiques 24-bit BURR BROWNDeacutelai de propagation 15msMeacutemorisations des configurations 32 preset
CONTROLES Affichage LCD graficoBoutonsCommandes ESC - MENU - FUNCTIONS SELECTION
ENTERENTREESSORTIESEntreacutee analogique ndeg2 x XLR (3 broches femelle)
Impeacutedance dentreacutee gt10KOhmNiveau maximum +21dBu senza PAD
+27dBu con PADSortie analogique ndeg6 x XLR (3 broches macircle )
Impeacutedance de sortie 50OhmNiveau maximum +21dBuType Balanceacute
Entreacutee numeacuterique ndeg1x XLR (3 broches femelle)Type SPDIF-AESEBU (AES3)
Sortie numeacuterique ndeg1x XLR (3 broches macircle )Type conforme agrave la norme de lentreacutee
EntreacuteesSortie Rdnet ndeg2 x XLR RJ45 (cacircble CAT 5)USB Type B
PARAMETRES DE CONTROLE DU SONGain -80dB a +20dB eacutetape 01dBDeacutelai Entreacutee 0 a 729mS eacutetape 01 mS
Sortie 0 a 340mS eacutetape 01mSRotation de phase 0deg - 180deg
COMPRESSIONSeuil -80dB a +20dB eacutetape 01dBRapport 11 a Inf1 eacutetape 001Gain agrave la sortie 0dB a 40dB eacutetape 01dBTemps dattaque 1mS a 1000mS eacutetape 01mSTemps de relacircchement 1mS a 1000mS eacutetape 01mSTemps de maintien 1mS a 1000mS eacutetape 01mS
EGALISEURS12 eacutegaliseurs pour chaque entreacutee et sortieType PEQ (parameacutetrique) Hi-shelf Lo-sheft
Freacutequence 20Hz a 20KHz eacutetape 1HzGain -30dB a +15dB eacutetape 001dBBande 005dB a 2dB eacutetape 001dB (uniquement pour PEQ)
FILTRES CROSSOVERFiltre Linkwitz Riley
Type HF high-shelfLF low-shelf
Pente 12dBoct - 24dBoct - 48dBoctFreacutequence de coupure 5Hz a 20KHz eacutetape 1Hz
ALIMENTATION Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)POIDS 19Kg
Remarques Speacutecifications sujettes agrave modifications sans preacuteavis
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
2 VIE ATTIVO2 WAY ACTIVE
3 VIE PASSIVO3 WAY PASSIVE
L
L
A
A
HIGH L
MID L
LOW HIGHMID RHIGHMID L
LOW L
HIGH R
MID R
LOW R
R
R
B
B
1
1
2
2
3
3
456
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
Menu Matrix configurationMatrix
57 58
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
EROUIG ATRIX TNM
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
OU
TP
UT
1
OU
TP
UT
2
OU
TP
UT
3
OU
TP
UT
4
OU
TP
UT
5
OU
TP
UT
6
AE
S-E
BU
OU
TP
UT
INP
UT
A
AE
S-E
BU
INP
UT
INP
UT
B
D D D D D D
D D
A A A A A A
A SA
MP
LE
RA
TE
CO
NV
A
LIN
KA
BL
E
SC
HE
MA
A B
LO
CC
HI -
BL
OC
K D
IAG
RA
MB
LO
CK
SC
HA
LT
BIL
D -
SC
HE
MA
S F
ON
CT
ION
NE
LS
LINE ARRAY SUB MONO ATTIVO
LINE ARRAY SUB MONO ACTIVEINGRESSI - INPUT
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
L
L
L
A
A
A
AESEBU IN
AESEBU IN
AESEBU IN
AESEBU OUT
AESEBU IN
AESEBU IN
AESEBU OUT
R
R
R
LR
B
B
B
123456
HIGHMID L
HIGHMID L HIGHMID R
HIGHMID R
LOW L LOW R
LAYER
DISPLAY MEMORY
FADER MODE
LAYER
DISPLAY MEMORY
FADER MODE
Ingresso ANALOGICO
ANALOG Input
Collegamento in cascata
Link connections
Ingresso DIGITALE
DIGITAL inputA B
BALANCED AUDIO INPUTS
-6dB
PUSH PUSH
IN OUT
AES EBUPUSH
Oppure
or
Oppure
or
Menu Option configurationOption
Menu Option configurationOption Menu Option configurationOption
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type Analog
AES out An In
Input type Analog
AES out An In
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
59 60
InA-B Src Dig InInA-B Src Dig InInA-B Src An InInA-B Src An In
frequenzaHz
dB
Gu
ad
ag
no
60 200 2800
0dB0dB
-6dB
Esempio di un sistema a 3-vie
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
Out 1 Out 2 Out 3
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Esempio di un sistema a 3-vie
61 62
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
26NAC 26NAC
R TE
DO
R
MO LEU O R CE S
E O TR L A
S O
O C ND I P
P hsuernE t
o su cti nF nel rS e tc o
E CSME UN
IGCHTE OL SN EOBd
ocaL l
M
0
484
467
430
44
31
75
12
7
DIMENSIONI DIMENSIONSABMESSUNGEN DIMENSIONS
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
109
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
oLrsquo AC26N gestisce 12 filtri per ogni singolo canale di ingresso e uscita con tre diversi tipi configurazioni
Passano tutte le frequenze ma aumenta e diminuisce solo quelle attorno alla frequenza centrale per una determinata banda e un guadagno stabilito
- Equalizzatore high-shelf passa tutte le frequenze ma aumenta o attenua le frequenze sopra la frequenza di taglio selezionata per il guadagno indicato
- Equalizzatore low-shelf passa tutte le frequenze ma aumenta o attenua le frequenze inferiori alla frequenza selezionata per il guadagno indicato
- Equalizzatore PEQ (peaking equalizer) egrave ideale per identificare isolare e correggere solo una determinata gamma di frequenze
f Numerazione dei 12 filtri disponibili per quellrsquoingresso oppure uscita1
f Viene visualizzato il tipo di filtro2
Dis Disinserito (non presente)
PEQ Peaking equalizer
Sh H Filtro high-shelf
Sh L Filtro low-shelf
Esempi PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
NOTA BENEIl parametro Bw determina il campo di frequenze adiacenti alla frequenza impostata dove viene attivato il filtro maggiore egrave il valore Bw maggiore e egrave il campo di frequenze (1Bw=1 ottava)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONEQuesto comando apre la finestra del menugrave compressione del singolo canale
g ) Treshold1
Identifica la soglia dove inizia il rapporto di compressione Il valore di base 11
g ) Ratio2
Indica il rapporto di conversione tra il segnale in ingresso e quello in uscita
g ) Post Gain Attach Release Hold3
Questi dati sono in funzione del rapporto di conversione che si vuole ottenerePost Gain egrave il guadagno di uscitaAttack egrave il tempo di attacco Release egrave il tempo di rilascioHold il tempo di mantenimento
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
DESCRIZIONE FINESTRA MENUrsquo ldquoPresetrdquoQuesta finestra permette di memorizzare fino a 32 configurazioni nellrsquoAC26NLa ditta costruttrice fornisce il sistema con un programma impostato e salvato nella posizione ldquo0rdquo e non sovrascrivibile
032 Indica la locazione di salvataggio della configurazioneQuesto numero appare anche nella finestra ldquoMetersrdquo nella posizione (g) in qualsiasi momento il programma utilizzato puograve essere visualizzato dellrsquoutente
Empty Preset Ersquo il nome che viene associato al numero della locazione quando non egrave salvato nessun settaggio (vuoto)
Local preset Ersquo il nome che viene associato al numero di locazione quando viene salvata una configurazione NB = Ersquo possibile salvare un settaggio con il nome desiderato al max 16 lettere solo utilizzando lrsquointerfaccia tramite il computer
Selezionando un programma appare la seguente finestra
Viene indicato il nome del programma assegnatoPer intervenire sulla applicazione sono a disposizione 3 scelte possibili
Save Il programma viene salvato nella memoria dellrsquoAC 26N
Del Il programma viene cancellato
Load Il programma viene caricato e pronto per essere utilizzato
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
11
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
12
DESCRIZIONE FINESTRA MENUrsquo ldquoX-OverrdquoQuest a finestra permette di selezionare per ogni uscit a un filtro p assa basso un filtro p assa alto oppure tramite la combinazione di entrambe creare un filtro p assa bandaIl filtro presente egrave un Linkwitz-Riley dove egrave possibile selezionare la pendenza di 12dBoct 24dBoct oppure 48dBoct e la relativa frequenza di t aglio
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) CANALI USCITA
I connettori di uscita sono identificati utilizzando le medesime indicazioni presenti sulla serigrafia del retro del dispositivo
b) FILTRO CROSSOVERSelezionare il filtro a seconda delle necessitagrave Ersquo possibile selezionare
Dis Nessun filtro attivato
HP Filtro passa-alto lasciare passare solo la parte di segnale audio superiore alla frequenza di taglio
LP Filtro passa-basso lasciare passare solo la parte di segnale audio inferiore alla frequenza di taglio
Configurazione Filtro Passa basso Passa alto
Nessuna Dis Dis
Passa alto HP Dis
Passa basso Dis LP
Passa banda HP LP
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
c) PENDENZA DI ATTENUAZIONESelezionare la pendenza di attenuazione del segnale audio in base alla diminuzione che si desidera ottenere Piugrave elevata egrave la pendenza di attenuazione a paritagrave di frequenza di taglio maggiore egrave la selezione del segnale Ersquo possibile selezionare
12 corrisponde a 12dboct
24 corrisponde a 24dboct
48 corrisponde a 48dboct
d) FREQUENZA DI TAGLIOPermette drsquoimpostare la frequenza di passaggio delle sole frequenze inferiori (filtro passa-basso) o delle sole frequenze superiori (filtro passa-alto)La scelta del taglio egrave in funzione della riproduzione che si vuole ottenereLrsquounitagrave di misura utilizzata egrave Hz
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
DESCRIZIONE FINESTRA MENUrsquo ldquoMatrixrdquoPermette di selezionare per ogni uscita il segnale in ingresso da utilizzare come sorgente
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) CANALI USCITAIdentificazione del canale in uscita da impostare
b) IDENTIFICAZIONI INGRESSISelezionare il tipo di segnale da abbinare a ogni singola uscita in base alle proprie necessitagrave Ersquo possibile selezionare
In A Viene associato il segnale in ingresso laquoAraquo
In B Viene associato il segnale in ingresso laquoBraquo
In A+B Viene associato la somma algebrica dei due segnali in ingresso laquoAraquo e laquoBraquo
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
DESCRIZIONE FINESTRA MENUrsquo ldquoOptionrdquoPermette di visualizzare le impostazioni sistema come lrsquoassegnazione degli ingressi e delle uscite attenuazione il contrasto del display e la versione del firmware
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711
InA-B SrcQuesta opzione permette di impostare il tipo di segnale audio in ingresso
An In = segnali audio analogici (ingressi ldquoArdquo e ldquoBrdquo)
Dig In = segnali audio digitali (ingresso AESEBU)
DigOut SrcQuesta opzione permette di selezionare la sorgente audio che verragrave indirizzata sul connettore AESEBU OUT (uscita digitale)
An In = segnali audio presenti negli ingressi analogici
Dig In = segnali audio presenti sullrsquoingresso digitale
OUT 1-2 = segnali audio presenti sulle uscite 1 e 2
OUT 3-4 = segnali audio presenti sulle uscite 3 e 4
OUT 5-6 = segnali audio presenti sulle uscite 5 e 6
Input ModePermette di configurare gli ingressi
Indip = sono indipendenti ed autonomi non sono soggetti a vincoli di alcun genere tra di loro
Linked = sono uniti e funzionano in modalitagrave stereoI compressori i filtri i ritardi il volumesono identici per i due canali
13
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
14
Atten Pad
Indica come egrave impostato il selettore ldquo-6dBrdquo posto sul retro [rif 5] Ersquo necessario attivare questo selettore quando i livelli di ingresso analogici sono troppo elevati Il selettore viene attivato solo tramite il pulsante nel menugrave egrave solo una visualizzazione
0dB = selettore non attivatoI segnali di ingresso sono i medesimi della sorgente in ingresso
-6dB = selettore attivatoI segnali in ingresso vengono attenuati di -6dB dal processore interno
Contrast
Consente di regolare il contrasto del display LCD per compensare la differenza di luminositagrave con il luogo di installazione Una maggiore chiarezza del display permette di navigare allrsquointerno dei menugrave in modo corretto e veloceIl settaggio in uscita dalla ditta produttrice egrave 60
10 piugrave chiaro 60 piugrave scuro 100
Fw Vers
Indica la versione del firmware del processore
SPECIFICHE TECNICHE
PRESTAZIONI AUDIORisposta in frequenza +- 01dB (20 to 30kHz)Gamma dinamica 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsione 0002 (1kHz +4dBu)
PRESTAZIONI AUDIO DIGITALI Processore DSP 2856-bit Frequenza elaborazione dati 48KHzConvertitori analogici 24-bit BURR BROWNRitardo di propagazione 15msMemorizzazioni configurazioni 32 preset
CONTROLLI Diplay LCD graficoPulsantiComandi ESC - MENU - FUNCTIONS SELECTION
ENTER
INGRESSIUSCITEIngresso analogico ndeg2 x XLR (3 poli femmina)
Impedenza di ingresso gt10KOhmLivello massimo +21dBu senza PAD
+27dBu con PADUscita analogica ndeg6 x XLR (3 poli maschio)
Impedenza di uscita 50OhmLivello massimo +21dBu Tipo Bilanciato
Ingresso digitale ndeg1x XLR (3 poli femmina)Tipo SPDIF-AESEBU (AES3)
Uscita digitale ndeg1x XLR (3 poli maschio)Tipo conforme allo standard dellrsquoingresso
IngressiUscita RDnet ndeg2 x XLR RJ45 (cavo CAT 5)USB Tipo B
PARAMETRI CONTROLLO AUDIOGuadagno -80dB a +20dB passo 01dBRitardo
ingresso 0 a 729mS passo 01 mSuscita 0 a 340mS passo 01mS
Rotazione di fase 0deg - 180deg
COMPRESSIONESoglia -80dB a +20dB passo 01dBRapporto 11 a Inf1 passo 001Guadagno in uscita 0dB a 40dB passo 01dBTempo di attacco 1mS a 1000mS passo 01mSTempo di rilascio 1mS a 1000mS passo 01mSTempo di mantenimento 1mS a 1000mS passo 01mS
EQUALIZZATORI12 equalizzatori per ogni ingresso e uscitaTipo PEQ (parametrico) Hi-shelf Lo-sheft
Frequenza 20Hz a 20KHz passo 1HzGuadagno -30dB a +15dB passo 001dBBanda 005dB a 2dB passo 001dB (solo per PEQ)
FILTRI CROSSOVERFiltro Linkwitz Riley
Tipo HP Passa-AltoLP Passa-Basso
Pendenza 12dBoct - 24dBoct - 48dBoctFrequenza di taglio 5Hz a 20KHz passo 1Hz
ALIMENTAZIONE Full-range 100-240Vac 50-60HzDIMENSIONI 430482x43x130mm (LxHxD)PESO 19Kg
Note Specifiche soggette a variazioni senza preavviso
CLASSIFICAZIONE EMIIn accordo alle normative EN 55103 lapparato egrave progettato e idoneo allutilizzo in ambienti Elettromagnetici E3 o inferiori (E2 E1)
INTRODUCTIONAC26N is a digital sound processor for the management of audio systems designed for fixed and touring installations AC26N uses the most modern technology with 2856 bit processors and high performance 24 bits ADDA converters The functions available in the processor are input and output levels delay polarity 12 equalization bands for each input and output channel multiple crossover and high performance limiter The control resolution of the filters is 1Hz Inputs and outputs can be set according to many configurations to meet any need AC26N can be controlled in real time and each one of its parameters can be configured on the front panel and through a computer by means of an intuitive graphical interface accessible through the software DVA Network and a dedicated RDnet or USB network connectionThe CPU and DSP software update via PC allows to keep the device up to date It is possible to save and recall 32 preset configurations
Package Contents- AC26N - Operating manual- Software CD- Power cord
Characteristics- 2 Inputs and 6 Outputs with flexible routing- AESEBU addressable stereo inputs and outputs - 2856 bit DSP- BURR-BROWN high performance 24 bit AD converters- Frequency resolution of the filters 1 Hz - 12 parametric equalizers for each input and output- 2 crossover filters for each output with selectable slope 122448 dBoct- High performance DRC multi configuration for limitercompression configuration of
each input and output- Adjustable level in dB polarity and delay for each input and output- Firmware Update via PC- Graphic LCD Display- 32 pre-sets can be stored by the user- USB interface for configuration and control via computer- RDnet interface that allows to control up to 256 remote devices
PC
PC
RDNET hub(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FUNCTIONS FRONT PANEL
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
CONTROLS AND FUNCTIONS
1) DISPLAYThe graphic LCD display allows to view and edit the AC26N information without a computer The display contrast can be set within the main menu
2) ldquoFunctions Selectorrdquo and ldquoPush Enterrdquo KNOBThis control allows to move select and change the parameters within the displayed menusRotation of the knob (Function Selector)- it allows to browse the menu pages- it allows to change the selected parametersPush the knob (Push Enter)- it allows to selectconfirm the parameters
3) ESC button This control allows to exit the displayed menus or to return to the previous view
4) MENU button This control allows to directly access the main menu
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
En
glis
hE
nglis
hu
ser
man
ual
user
man
ual
16
user
man
ual
user
man
ual
Englis
hE
nglis
h
15
DVA USB Manager
The firmware of the amplifier module can be updated via the USB portTo make this update possible and simple a dedicated program has been developed
It is recommended to download DVA USB Manager free software directly from dB Technologies (wwwdbtechnologiescom) in the special section laquoSoftware amp Controllerraquo
DVA Network
The AC26N is equipped with proprietary network interface called RDNET for PC interface through a device (RDNET control)For this purpose a proprietary communication protocol has been developed for receiving and sending data this connection permits real-time monitoring of the diffuser parameters such as output power amplifier temperature limiter status etc It is also possible to select various equalizations or create new ones set the desired volume levels using the specific plug-in
It is recommended to download DVA Network free software directly from dB Technologies (wwwdbtechnologiescom) in the special section laquoSoftware amp Controllerraquo DOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
REAR PANEL CONNECTIONS
1586 75 141210 11 13 169 17
14) USB connectorThis USB connector (type B) allows to connect the processor to a compute to check and update the firmware via a dedicated program (DVA Network)
15) ldquoMAINSrdquo POWER CONNECTIONIt allows to connect the provided power cord
16) FUSE HOLDER ldquoFUSErdquoMain power supply fuse housing
17) ldquoPOWERrdquo MAIN SWITCHThis switch allows to switch on and off the device
PUSH
P SHU
SHPU
P SHU
PUSH
CONNECTIONS
Analog Audio ConnectionsBalanced connections allow to minimize the cable induced noise so cable can be longerSuch connections may be used both on inputs and outputsXLR connector must be cabled with pin 1 to ground pin 2 to hot (+) and pin 3 to cold (-) With shielded cables connect the shield to pin 1XLR-XLR e XLR-Jack 14(63 mm) connection cables can be used to connect the AC26N
12
3
Input
XLR - female
Pin 3 =NegativeCold-VE Phase
Pin 3 =NegativeCold-VE Phase
1 2
3
Output
XLR - Male
Pin 2 = PositiveHot+VE Phase
Pin 2 = PositiveHot+VE Phase
Pin 2 = PositiveHot+VE Phase
Pin 2 = PositiveHot+VE Phase
Pin 1 =ScreenGroundEarth
Pin 1 =ScreenGroundEarth
Pin 1 =ScreenGroundEarth
Pin 1 =ScreenGroundEarth
Ring
Sleeve
Tip = PositiveHot+VE Phase
Ring = NegativeCold-VE Phase
Sleeve=ScreenGroundEarth
Sleeve=ScreenGroundEarth
Tip
The unbalanced connections can also be used However the cable induced noise increases and cable length must not exceed 5 metersSuch connections may be used both on inputs and outputsUnbalanced connection may lower the level of the input signal up to 6dB in order to overcome this drawback connect pin 3 to ground although this can increase the noise
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
18
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
17
CONTROLS AND FUNCTIONS
5) -6dB SELECTORThis selector allows to reduce all the analog XLR [6] input levels by 6 dB at the same time to compensate for the high output levels on the mixers or other audio devices When the input signal level bar on the display [1] remains always at full scale this means that the input signal level is excessive and a -6 dB attenuation is recommendedIn the Option menu it is possible to check when the selector is activated
6) INPUT CONNECTORS ldquoArdquo AND ldquoBrdquoInputs balanced at line levelCapable to accept XLR male connectors
7) OUTPUT CONNECTORS ldquo1rdquo ldquo2rdquordquo 3rdquo ldquo4rdquo ldquo5rdquo AND ldquo6rdquoOutputs balanced at line level Capable to accept XLR famale connectors
Be careful to correctly connect each output to each speaker or amplifier according to the settings of each channels to avoid damages and malfunctions
ldquoAESEBUrdquo Section
8) INPUT CONNECTORIn addition to the analog audio inputs a SPDIF-AESEBU (AES3) digital audio input is also provided It can be selected via the setup menuSuch input requires a balanced connection trough an XLR connector with a 110 ohm twisted 3-wires cable
9) ldquoOUTrdquo OUTPUT CONNECTORThis connector allows to forward audio signals available at the digital or analog inputs or outputs The source must be set by means of the Option menuThe connection must comply with the same standard of the input [8]
RDNET Section
10) DATA INPUT CONNECTORData input RJ45 connector
11) ldquoDATA LINKrdquo OUTPUT CONNECTORRJ45 connector for data output used for serial link in cascade
12) ldquoONrdquo INDICATOR LIGHTThis green indicator turns on only when the AC26N has recognized the RDNET main unit and it is connected to it via computer
13) ldquoACTIVErdquo INDICATOR LIGHTThis yellow indicator flashes when data transmission between RDNET and the device is active
12
3
Input
XLR - female
1 2
3
Output
XLR - Male
Tip Gambo
Tip= Signal
Pin 3 = Link to Pin 1
Pin 3 = Link to Pin 1
Digital Audio Connections (AESEBU)AESEBU (AES3 protocol) is and a balanced input electrically insulated by means of a transformer It allows carrying two audio channels in a single two-wires shielded cable The cable characteristics are twisted 3 poles impedance 100 ohm shielded equipped with XLR connector (AES3 standard)
RDnetEach RDNet port on Control 2 and Control 8 can be connected to maximum 32 cascade-connected compatible devices In the example below the control unit RDNET CONTROL 2 port is connected to the DATA INPUT of an AC 26N whose parallel DATA LINK output is sent to the input of the next AC26N In the example [n] is a number between 3 and 32 (maximum limit for the devices connected to a sub-network)
RJ 45
|1|2|3|4|5|6|7|8|
The overall length of a CAT5 sub-network cable cannot exceed 900 meters
The connector must be connected as follows
1 - Available for other functions (for example audio +) 2 - Available for other functions (for example audio -)3 - Available for other functions (for example analog ground)4 - digital ground5 - digital ground6 - Available for other functions (for example power supply)7 - RS 485 A8 - RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
POWER ON
When the device is turned on the initialization procedure starts It lasts few seconds The display shows the device model the company logo and a program loading progress bar
At the end of the installation process the display shows the Meters menu For further details about the indications refer to the paragraph MENU DESCRIPTION - METERS
AC26N is now ready for use
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION AND DISPLAY
To access the main menu window press the MENU key located on the device front panelIn any page of the menu press the ESC button to return to the previous screen
MAIN MENU
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
There are six menus in the processor They show andor configure the system parametersThe main menus are
Meters Input and output levels display program in progress display quick muting
Preset Store save and delete the system configurations
Matrix Select the outputs according to the input signal
Ch Job Configuration of each individual channel
X-Over Configuration of the cut-off frequency and the types of filters for each output
Option Assignment of the inputs and outputs display contrast firmware version inputs and other options
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
20
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
19
The menus and the individual options displayed can be selected by rotating the knob ldquoFUNCTION SELECTORrdquo ( ) To access the selection highlight the desired parameter and press the ldquoPush Enterrdquo ( | ) knobThe same procedure should be adoptd to select andor change the options inside each menu entry
MENU DESCRIPTION - ldquoMetersrdquo
This window allows to view the configuration and the general conditions of the inputs and outputs the version of the program used the program status and how the system is driven
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) INPUT AND OUTPUT CHANNELSThe input and output connectors are identified by the same information provided on the screen printing located on the device rear sideWith digital input signals the indications A and B concern the inputBy rotating the knob FUNCTION SELECTOR [2] input channels output channels and general muting indications are cyclically scrolled (d) the selected channel is highlighted
b) BAR COMPRESSION LEVEL CHANNEL MUTING
SIGNAL COMPRESSIONSignal compression is displayed by the vertical scrolling (top to down) of the right bar
MUTE Each channel can be individually muted Select the channel and press the Push Enter knob [2] to confirm the change of status The indication of the channel will be replaced by the letter M and the bar will be completely highlightedTo restore normal operation repeat the actions described above
c) SIGNAL LEVEL BARThe level indication for each channel is provided by scrolling the left bar
d) GENERAL MUTINGIt is possible to mute all the inputs and outputs simultaneously Rotate the knob FUNCTION SELECTOR select the letter M and press the Push Enter knobTo restore normal operation repeat the actions described aboveThe general mute has the highest priority with respect to the muting of individual channels
e) CONTROL MODEIt shows how the AC26N is used andor to which devices it is connected
Local = stand-alone usage No connection to an external device
NET = directly connected to dedicated RDnet network and to computer
USB = directly connected to another computer via USB cable
f) SETTING STATUS INDICATIONThis indication shows if the loaded program was amended in one or more parameters with respect to the last saving operation
= original program
= program with modified parameters
g) SET PROGRAMThe number shows the program that is loaded and used by the system with reference to the saving position Refer to the ldquoPresetrdquo menu for further details
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
MENU DESCRIPTION - CH JOB
This window allows to view the configuration of each individual channel
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) INPUT AND OUTPUT CHANNELSThe input and output connectors are identified by the same information provided on the screen printing located on the device rear side
b) SIGNAL LEVELIt shows the signal gain The increased signal intensity is expressed in decibels (dB) Such parameter can be selected in the range from -8000 dB to +2000 dB in steps of 001 dB An increase of 6 dB is approximately equal to doubling - in a linear scale - the signal voltage levelIf the gain exceeds 0 dB the signal is amplified while if the gain is lower than 0 dB the signal is attenuated
c) SIGNAL DELAYThe reproduced audio signal may be delayed to perform an acoustic alignment This compensates for the different positions of the speakers during the installation and the sound reproduction it is expressed in ms The parameter can be selected in the range from 00 ms to 729 ms in steps of 01 msThe following formula can be used to align an audio signal
Delay = (GAPx1000)344
Delay = ms (in milliseconds)GAP = distance between speaker and reference point (in meters)Speed of sound = 344 ms
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
22
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
21
d) MUTEEach channel can be individually muted The same command can be activated in the Meters Menu
NOTE The general mute has the highest priority with respect to the muting of individual channels
e) PhaseIt performs a phase rotation of 180deg with respect to the input signalSuch phase rotation allows the optimization in special way for low frequencies in complex installations
M M
f) EQUALIZATIONThis control opens the menu controlling the single channel equalization It is mainly used to correct one or more frequencies that must be reduced or increased
The AC26N manages 12 filters for each individual channel input and output with three different kinds of configuration
- PEQ Equaliser (peaking equalizer) ideal to identify isolate and correct only a certain range of frequencies All frequencies pass only those around the centre frequency are increased and decreased for a given bandwidth and set gain
- High-shelf Equalizer All frequencies pass but frequencies above the selected cut-off frequency are increased or attenuated by the given gain
- Low-shelf Equalizer All frequencies pass but frequencies below the selected cut-off frequency are increased or attenuated by the given gain
f Numbering of the 12 available filters for the specific input or output1
f Displays the kind of filter2
Dis Switched off (not present)
PEQ Peaking equlizer
Sh H High-shelf Filter
Sh L Low-shelf Filter
Examples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
NOTE
The parameter Bw defines the range of frequencies close to the set frequency where the filter is activated the greater the value of Bw the wider is the frequencies range (1 Bw = 1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONThis control opens the menu controlling the compression for the single channel
g1) ThresholdIdentifies the starting threshold for the compression ratio Base value 11
g2) RatioIndicates the conversion ratio between input and output signal
g3) Post Gain Attach Release HoldThese data are in function of the conversion ratio to achieve Post Gain is the output gain Attack is the attack time Release is the release time Hold is the holding time
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
24
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
23
MENU DESCRIPTION - PRESET
This window allows to store up to 32 configurations in the AC26NThe manufacturer provides the system with a program set and saved in position 0 that is not possible to overwrite
032 Indicates the location where the configuration is savedThis number also appears in the window Meters in position (g) The program in use can be displayed at any time by the user
Empty Preset It is the name associated with the location number when no setting is saved (empty)
Local preset It is the name associated with the location number when a setting is saved NOTE = It is possible to save a setting with the desired name up to 16 letters only via the computer interface
When a program is selected the following window is displayed
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
The name of the assigned program is displayed3 possible choices are available when working on the application
Save The program is saved in the AC 26N memory
Del The program is deleted
Load The program is loaded and ready to be used
MENU DESCRIPTION - X-OVER
This window allows to select for each output a low pass filter a high pass filter or create a band-pass filter via the combination of bothThe available filter is a Linkwitz-Riley where it is possible to select slopes of 12 dBoct 24 dBoct or 48 dBoct and their cut-off frequency
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) OUTPUT CHANNELS
The output connectors are identified by the same information provided on the screen printing located on the device rear side
b) CROSSOVER FILTERSelect the filter according to needs It is possible to select
Dis No filter enabled
HP High-pass filter set it to allow only the part of audio signal above the cut-off frequency
LP Low-pass filter set to allow only the part of audio signal below the cut-off frequency
Filter configuration Low-pass High-pass
Nothing Dis Dis
High-pass HP Dis
Low-pass Dis LP
Band-pass HP LP
12dBoct
24dBoct
Hz
dB
48dBoct
12dBoct
24dBoct
frequency
frequency
frequency
frequency
Hz
dB
48dBoct
c) ATTENUATION SLOPESelect the attenuation slope of the audio signal on the basis of the desired attenuation The higher the attenuation slope at the same cut-off frequency the greater the signal selection It is possible to select
12 equal to 12 dBoct
24 equal to 24 dBoct
48 equal to 48 dBoct
d) CUT-OFF FREQUENCYTo set the passing frequency for the lower frequencies only (low-pass filter) or the higher frequencies only (high-pass filter)The choice of the cut-off depends on the desired sound reproductionThe unit of measurement used is Hz
Hz
Hz
dB
dB
Ga
inG
ain
Ga
inG
ain
f0
f0
0dB0dB
0dB
-6dB
-6dB
0dB
0dB
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
26
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
25
MENU DESCRIPTION - MATRIX
For each output it allows to select the input signal to use as the source
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) OUTPUT CHANNELSIdentification of the output channel to set
b) IDENTIFICATIONS OF THE INPUTSIt selects the type of signal to match each output as needed It is possible to select
In A Associated with the input signal ldquoArdquo
In B Associated with the input signal ldquoBrdquo
In A+B Associated with the algebraic sum of the two input signals ldquoArdquo and ldquoBrdquo
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
MENU DESCRIPTION - OPTION
Allows to display the system settings such as the allocation of the inputs and outputs attenuation display contrast and firmware version
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcThis option allows to set the type of input audio signal
An In = Analog audio signals (inputs A and B)
DigIn = Digital audio signals (AESEBU input)
DigOut SrcThis option allows to select the audio source that will be forwarded to the connector AESEBU OUT (digital output)
An In = Audio signals available at analog inputs
Dig In = Audio signals available at digital inputs
OUT 1-2 = Audio signals available on outputs 1 and 2
OUT 3-4 = Audio signals available on outputs 3 and 4
OUT 5-6 = Audio signals available on outputs 5 and 6
Input ModeIt allows to configure the inputs
Indip = They are independent not subject to constraints of any kind between them
Linked = They are connected and work in stereo mode Compressors filters delays volume are identical for the two channels
Atten PadIt shows how to set the -6 dB switch located on the rear side [Ref 5] It is necessary to activate this selector when the analog input levels are too high The selector can be activated only by means of the button the menu is for display only
0 dB = Selector not activated The input signals are the same as the input source
-6 dB = Selector activated The input signals are attenuated by -6 dB with reference to the inner
processor
ContrastAllows to adjust the LCD display contrast to compensate for the brightness difference at the installation sites Greater display brightness allows to navigate correctly and quickly within the menuThe manufacturer output setting is 60
10 More bright 60 More dark 100
Fw VersIt shows the processor firmware version
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
28
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
27
TECHINICAL SPECIFICATION
AUDIO PERFORMANCEFrequency Response +- 01dB (20 to 30kHz)Dynamic Range 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistortion 0002 (1kHz +4dBu)
DIGITAL AUDIO PERFORMANCE Processor DSP 2856-bit Data processing Frequency 24-bit BURR BROWNAnalog converters 24-bit BURR BROWNPropagation Delay 15msStoring configurations 32 preset
CONTROLS Display LCD graficoButtonsControls ESC - MENU - FUNCTIONS SELECTION
ENTERINPUTSOUTPUTSAnalog Input ndeg2 x XLR (3 pole female)
Input impedance gt10KOhmMaximum Level +21dBu senza PAD
+27dBu con PADAnalog Output ndeg6 x XLR (3 pole male)
Output impedance 50OhmMaximum Level +21dBu Type Balanced
Digital Input ndeg1x XLR (3 pole female)Type SPDIF-AESEBU (AES3)
Digital Output ndeg1x XLR (3 pole male)Type Compliant with the input standard
RDnet InputsOutput ndeg2 x XLR RJ45 (CAT 5 cable)USB Tipo B
SOUND CONTROL PARAMETERSGain -80dB a +20dB step 01dBDelay
Input 0 a 729mS step 01 mSOutput 0 a 340mS step 01mSPhase Rotation 0deg - 180deg
COMPRESSIONThreshold -80dB a +20dB step 01dBRatio 11 a Inf1 step 001Output gain 0dB a 40dB step 01dBAttack time 1mS a 1000mS step 01mSRelease time 1mS a 1000mS step 01mSHold time 1mS a 1000mS step 01mS
EQUALIZERS12 equalizers for each input and outputType PEQ (parametrico) Hi-shelf Lo-sheft
Frequency 20Hz a 20KHz step 1HzGain -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (only with PEQ)
CROSSOVER FILTERSFilter Linkwitz Riley
Type HP High-pass LP Low-pass
Slope 12dBoct - 24dBoct - 48dBoctCUT-OFF FREQUENCY 5Hz a 20KHz passo 1Hz
POWER SUPPLY Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)
1719x17x51 inch (WxHxD)WEIGHT 19Kg
(42 lbs)Note Specifications subject to change without notice
EMI CLASSIFICATIONAccording to the standards EN 55103 this equipment is designed and suitable to operate in E3 (or lower E2 E1) Electromagnetic environments
EINLEITUNG
Verpackungsinhalt
Eigenschaften
AC26N ist ein digitaler Audio-Prozessor fuumlr die Verwaltung von Audio-Systemen der fuumlr feste und mobile Installationen entwickelt wurde AC26N benutzt die modernste Technologie mit 2856 bit-Prozessoren und 24-bit-ADDA-Wandlern mit hoher Leistungsfaumlhigkeit Die verfuumlgbaren Funktionen des Prozessors sind Ein- und Ausgangsstufen Verzoumlgerung (delay) Polaritaumlt 12 Equalizer-Frequenzen fuumlr Ein- und Ausgangskanal viele Crossover-Wahlmoumlglichkeiten und Limiter mit hoher Leistung Die Filter-Kontrolle hat eine Aufloumlsung von 1 Hz Die Ein- und Ausgaumlnge koumlnnen mit unterschiedlichen Einstellungen geregelt werden um allen Anforderungen gerecht zu werden AC26N kann in Echtzeit kontrolliert werden und jeder Parameter kann am Frontpaneel und vom Computer mit intuitiver graphischer Schnittstelle mittels Software DVA Network zugaumlnglich und einer Netzverbindung RDnet oder uumlber USB eingestellt werdenDie SW-Aktualisierung fuumlr CPU und DSP uumlber PC erlaubt die Vorrichtung auf dem aktuellen Stand zu halten Man kann 32 vorgesehene Konfigurationen speichern und aufrufen
- AC26N - Bedienungsanleitung- Software-CD- Versorgungskabel
- 2 Ein- und 6 Ausgaumlnge mit flexibler Adressierung- Adressierbarer Stereo-Ein- und Ausgang AESEBU - DSP 2856-bit- AD-Wandler BURR BROWN 24-bit mit hoher Leistungsfaumlhigkeit- Aufloumlsungsfrequenz der Filter 1 Hz - 12 parametrische Equalizer fuumlr jeden Ein- und Ausgang- 2 Crossover-Filter fuumlr jeden Ausgang mit auswaumlhlbarer Neigung 122448dBoct- DRC Multikonfiguration mit hoher Leistungsfaumlhigkeit fuumlr die Konfiguration des
Limitersder Kompression jedes Ein- und Ausgangs- Einstellbare dB-Stufe Polaritaumlt und Verzoumlgerung (delay) fuumlr jeden Ein- und Ausgang- Firmware-Aktualisierung uumlber PC- Graphisches LCD-Display- 32 Voreinstellungen vom Benutzer einstellbar- USB-Schnittstelle fuumlr die Kontrolle und Konfiguration mit dem Computer- Schnittstelle RDnet welche erlaubt bis zu 256 fern liegende Vorrichtungen
zu kontrollieren
PC
PC
RDNET control(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FUNKTIONEN VORDERSEITE
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
BEDIENUNGEN UND FUNKTIONEN
1) DISPLAYDas graphische LCD-Display erlaubt die Informationen des AC26N ohne einen Computer zu benutzen anzuzeigen und zu editieren Der Kontrast kann im Hauptmenuuml eingestellt werden
2) DREHGRIFF Functions Selector UND Push EnterDiese Kontrolle erlaubt sich in den Menuumls auf dem Display zu bewegen und die Parameter auszuwaumlhlen und zu veraumlndernDrehung des Drehgriffes (Functions Selectors)- Man kann sich innerhalb der verschiedenen Menuumlseiten bewegen- Erlaubt die Veraumlnderung der ausgewaumlhlten ParameterDruck des Drehgriffes (Push Enter)- Erlaubt die AuswahlBestaumltigung der Parameter
3) Taste ldquoESCrdquo Diese Kontrolle erlaubt die angezeigten Menuumls zu verlassen oder zur vorherigen Anzeige zuruumlckzukehren
4) Taste ldquoMenuumlrdquo Diese Kontrolle erlaubt den direkten Zugang zum Hauptmenuuml
Deuts
chD
euts
chB
ed
ien
un
gsan
leit
un
gB
ed
ien
un
gsan
leit
un
g
29
Deuts
chD
euts
chB
ed
ien
un
gsan
leit
un
gB
ed
ien
un
gsan
leit
un
g
30
DVA USB Manager
Die Firmware des Verstaumlrkermoduls kann uumlber den USB-Anschluss aktualisiert werdenUm diesen Vorgang zu ermoumlglichen und zu vereinfachen wurde ein dediziertes Programm entwickelt das beim Hersteller angefordert und auf einen Computer installiert werden muss
Wir empfehlen die Software DVA USB Manager direkt von der Webseite dB Technologies (wwwdbtechnologiescom) im Abschnitt laquoSoftware amp Controllerraquo herunterzuladen
DVA Network
AC26N ist mit einer eigenen als RDNET bezeichneten Netzschnittstelle ausgestattet dank der es uumlber ein Interface (RDNET Control) an einen Computer angeschlossen werden koumlnnenHierzu wurde ein Kommunikationsprotokoll entwickelt mit dem die Daten empfangen und gesendet werden Dank dieser Verbindung koumlnnen die Lautsprecherparameter wie Ausgangsleistung Verstaumlrkertemperatur Limiterstatus usw in Echtzeit kontrolliert werden Auszligerdem koumlnnen verschiedene Entzerrungen ausgewaumlhlt bzw neue erstellt werden oder die gewuumlnschte Lautstaumlrke eingestellt werden
Wir empfehlen die Software DVA_Network direkt von der Webseite dB Technologies (wwwdbtechnologiescom) im Abschnitt laquoSoftware amp Controllerraquo herunterzuladenDOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
RUumlCKWANDANSCHLUumlSSE
1586 75 141210 11 13 169 17
14) USB-SteckverbinderDieser USB-Steckverbinder (Typ B) erlaubt den Prozessor an einem Computer anzuschlieszligen um die Firmware mit dem speziellen Programm (DVA Network) zu kontrollieren und zu aktualisieren
15) STROMANSCHLUSS MAINSErlaubt den Anschluss des mitgelieferten Versorgungskabels
16) SICHERUNGSTRAumlGER FUSEAufnahme fuumlr die Netz-Sicherung
17) HAUPTSCHALTER POWERDer Schalter erlaubt das Aus- und Einschalten des Audio-Controllers
BEDIENUNGEN UND FUNKTIONEN
5) WAHLSCHALTER -6dBDer Wahlschalter erlaubt das Level des analogen Eingangs XLR [6] um 6 dB zu verringern und gleichzeitig das hohe Ausgangslevel der Mixer oder anderer Audio-Vorrichtungen auszugleichen Wenn der Balken des Signallevels der Eingaumlnge auf dem Display [1] immer auf Maximum steht zeigt dies an dass das Signallevel am Eingang hoch ist und es wird empfohlen die Daumlmpfung -6dB zu benutzenIm Menuuml Option ist es moumlglich zu kontrollieren ob der Wahlschalter aktiviert ist
6) STECKVERBINDER AM EINGANG A UND BAuf Leitungslinie ausgeglichene EingaumlngeSie koumlnnen auch XLR-Steckdosen aufnehmen
7) AUSGANG-STECKVERBINDER ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo UND ldquo6rdquoAuf Leitungslinie ausgeglichene Ausgaumlnge Sie koumlnnen auch XLR-Stecker aufnehmen
Darauf achten dass die Ausgaumlnge korrekt entsprechend der Einstellungen der einzelnen Kanaumlle an den Lautsprechern oder Verstaumlrkern angeschlossen sind um Schaumlden und Fehlfunktionen vorzubeugen
Abschnitt ldquoAESEBUrdquo
8) EINGANGS-STECKVERBINDER INZusaumltzlich zu den analogen Audio-Eingaumlngen wurde ein digitaler Audio-Eingang SPDIF-AESEBU (AES3) vorgesehen der uumlber das Setup-Menuuml ausgewaumlhlt werden kannDer Eingang erfordert einen ausgeglichenen Anschluss mit einem XLR-Steckverbinder mit einem verdrillten Kabel mit 3 Leitern von 110 Ohm
9) AUSGANGS-STECKVERBINDER OUTDieser Steckverbinder erlaubt das Audiosignal an den analogen oder digitalen Eingaumlngen oder Ausgaumlngen zu verteilen Die Quelle muss uumlber das Menuuml Option eingestellt werdenDer Anschluss muss demselben Standard des Eingang entsprechen [Ref 8]
Abschnitt ldquoRDNETrdquo
10) EINGANGS-STECKVERBINDER DATA INPUTSteckverbinder RJ45 fuumlr den Dateneingang
11) AUSGANGS-STECKVERBINDER DATA LINKSteckverbinder RJ45 fuumlr den Datenausgang Fuumlr die serielle Kaskaden-Verbindung
12) LEUCHTANZEIGE ONDiese gruumlne Anzeige leuchtet nur wenn AC26N uumlber den Computer mit der Haupteinheit RDNET verbunden ist und diese erkannt hat
13) LEUCHTANZEIGE ACTIVEDiese gelbe Anzeige blinkt wenn eine Datenuumlbertragung zwischen RDNET und der Vorrichtung aktiv ist
PUSH
P SHU
SHPU
P SHU
PUSH
ANSCHLUumlSSE
Analoge Audio-AnschluumlsseDie ausgeglichenen Anschluumlsse erlauben die Geraumlusche der Kabel auf ein Minimum zu verringern und so die Benutzung langer Kabel zuzulassenDiese Anschluumlsse koumlnnen sowohl an den Ein- als auch an den Ausgaumlngen benutzt werdenDer XLR-Steckverbinder muss mit Pin 1 an Masse Pin 2 am Pluspol (+) und Pin 3 am Minuspol (-) angeschlossen werden Bei einem abgeschirmten Kabel muss die Abschirmung an Pin 1 liegenDie Verbindungskabel XLR-XLR und XLR-Jack 14 (63 mm) koumlnnen fuumlr den Anschluss
12
3
Eingang
XLR weiblichen
Pin 3 = MinuspolErkaumlltungphase -VE
Pin 3 = MinuspolErkaumlltungphase -VE
1 2
3
Ausgang
XLR maumlnnlichen
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Ring
Schaft
Spitze = PluspolWaumlrmephase +VE
Ring = MinuspolErkaumlltungphase -VE
Schaft=SchirmMasse
Spitze
Die nicht ausgeglichenen Anschluumlsse koumlnnen auch benutzt werden wenn die Kabelgeraumlusche ansteigen und diese Kabel duumlrfen nicht laumlnger sein als 5 MeterDiese Anschluumlsse koumlnnen sowohl an den Ein- als auch an den Ausgaumlngen benutzt werdenDie nicht ausgeglichenen Anschluumlsse koumlnnen das Signallevel am Eingang um 6 dB verringern um dem vorzubeugen muss Pin 3 an Masse angeschlossen werden obwohl dies das Geraumlusch verstaumlrken kann
12
3
Eingang
XLR weiblichen
1 2
3
Ausgang
XLR maumlnnlichen
Spitze Schaft
Spitze = Signal
Schaft=SchirmMasse
Pin 3 = zu Pin 1 gebruumlckt
Pin 3 = zu Pin 1 gebruumlckt
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
31
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
32
Digitales Audio (AESEBU)AESEBU (Protokoll AES3) ist ein ausgeglichener und uumlber einen Transformator elektrisch isolierter Eingang Er erlaubt die Benutzung von zwei Kanaumllen an einem einzigen abgeschirmten bipolaren Kabel Das gedrillte Kabel muss 3-polig sein eine Impedanz von 100 Ohm haben und mit einem XLR-Steckverbinder (AES3 Standard) abgeschirmt sein
RdnetJeder Port RDNet an Control 2 und Control 8 kann an max 32 kompatiblen Vorrichtungen die in Kaskade geschaltet sind angeschlossen werden Im nachstehenden Beispiel ist der Port der Kontrolleinheit RDNET CONTROL 2 am Eingang DATA INPUT eines AC 26N angeschlossen dessen paralleler Ausgang DATA LINK zum Eingang des naumlchsten AC26N geht Im Beispiel ist [n] eine Nummer zwischen 3 und 32 (maximale Anzahl der anschlieszligbaren Vorrichtungen an nur einem Netz)
RJ 45
|1|2|3|4|5|6|7|8|
Die Gesamtlaumlnge des Kabels CAT5 eines Unternetzes kann NICHT laumlnger als 900 Meter sein
Der Steckverbinder muss wie folgt angeschlossen sein1 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio +) 2 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio -)3 ndash Verfuumlgbar fuumlr andere Funktionen (zB analoge Masse)4 ndash digitale Masse5 ndash digitale Masse6 ndash Verfuumlgbar fuumlr andere Funktionen (zB Versorgung)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
EINSCHALTEN
Beim Einschalten der Vorrichtung startet die Initialisierung die einige Sekunden lang dauert Auf dem Display wird das Modell das Logo und der Fortschrittsbalken der Ladung des Programms angezeigt
Nach der Initialisierung erscheint auf dem Display das Menuumlfenster Meters Um die Angaben im Detail zu erfahren beziehen Sie sich bitte auf das Kapitel BESCHREIBUNG DES MENUumlFENSTERS Meters
AC26N kann jetzt benutzt werden
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
MENUrsquo PRINCIPALE
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Die sechs Menuumls im Prozessor zeigen undoder konfigurieren die Systemparameter
Anzeige der Levels der Ein- und Ausgaumlnge Anzeige des benutzten Programms und dessen Status Mute schnell
Speicherung Speicherung und Eliminierung der Systemkonfigurationen
Auswahl der Ausgaumlnge je nach Eingangssignal
Konfiguration jedes einzelnen Kanals
Konfiguration der Schnittfrequenzen und der Filtertypen fuumlr jeden einzelnen Ausgang
Zuordnung der Ein- und Ausgaumlnge Kontrast des Displays Firmware-Version Eingaumlnge und andere Optionen
Das Menuuml und die einzelnen Optionen der Anzeige koumlnnen durch Drehen des Drehgriffes FUNKTIONS SELECTOR ( ) ausgewaumlhlt werden
Die Hauptmenuumls sind
Meters
Preset
Matrix
Ch Job
X-Over
Option
Um die Auswahl zu treffen muss der gewuumlnschte Parameter auswaumlhlt und der Drehgriff Push Enter( | ) gedruumlckt werdenDas selbe Verfahren muss fuumlr die Auswahl undoder die Aumlnderung der Optionen innerhalb der Menuumlpunkte angewendet werden
BESCHREIBUNG DES MENUumlFENSTERS Meters
Diese Seite erlaubt die Konfigurationen und den allgemeinen Status der Ein- und Ausgaumlnge der benutzten Programmversion dessen Status und die Steuerung des Systems anzuzeigen
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
KONFIGURATION UND ANZEIGE
Um in das Fenster des Hauptmenuumls zu gelangen muss die Taste Menuuml ( ) auf der Frontseite der Vorrichtung gedruumlckt werdenMit der Taste ESC ( ) kehrt man von jeder Seite des Menuumls auf die vorherige Seite zuruumlck
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
33
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
34
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziertBei den digitalen Eingangssignalen entspricht die Angabe A und B dem EingangDreht man den Drehgriff FUNCTIONS SELECTOR [2] durchlaumluft man zyklisch die Ein- und Ausgangskanaumlle und die Angabe Mute allgemein (d) der ausgewaumlhlte Kanal wird hervorgehoben
b) BALKEN FUumlR DAS KOMPRESIONSLEVELMUTE KANAL
SIGNALKOMPRESSIONDie Signalkompression wird durch das Gleiten des rechten Balkens von oben nach unten angezeigt
MUTE Jeder einzelne Kanal kann auf Mute gestellt werden Den Kanal auswaumlhlen und den Drehgriff Push Enter [2] druumlcken um die Aumlnderung des Status zu bestaumltigen Die Angabe des Kanals wird durch den Buchstaben M ersetzt und der Balken wird komplett hervorgehobenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werden
c) BALKEN DES SIGNALLEVELSDie Anzeige des Levels jedes einzelnen Kanals wird durch das Gleiten des linken Balkens angezeigt
d) MUTE ALLGEMEINEs ist moumlglich alle Ein- und Ausgaumlnge gleichzeitig auf Mute zu schalten Den Drehgriff FUNCTIONS SELECTOR drehen den Buchstaben M waumlhlen und dann den Drehgriff Push Enter druumlckenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werdenDie allgemeine Stummschaltung hat eine houmlhere Prioritaumlt als die Stummschaltung der einzelnen Kanaumlle
e) ANSTEUERUNGSARTENEs wird angezeigt wie AC26N benutzt wird undoder an welchen Vorrichtungen es angeschlossen ist
= Benutzung stand-alone Kein Anschluss an einer externen Vorrichtung
= Direkt am Netz RDnet und am Computer angeschlossen
= Uumlber USB-Kabel direkt am Computer angeschlossen
f) ANZEIGE DES STATUS DER EINSTELLUNGENHier wird angezeigt ob einer oder mehrere Parameter des geladenen Programms im Vergleich zur letzten Speicherung veraumlndert wurden
Original-Programm
Programm mit veraumlnderten Parametern
g) EINGESTELLTES PROGRAMMDie Nummer zeigt das vom System geladene und benutzte Programm in Bezug auf die Lokalisierung der Speicherung an Fuumlr weitere Details beziehen Sie sich bitte auf das Menuuml Preset
Local
NET
USB
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
BESCHREIBUNG DES MENUumlFENSTERS Ch Job
Dieses Fenster erlaubt die Anzeige der Konfiguration jedes einzelnen Kanals
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) SIGNALLEVELZeigt die Signalstaumlrke an Das Ansteigen der Signalintensitaumlt wird in Dezibel (dB) ausgedruumlckt Der Parameter kann zwischen -8000 dB und +2000 dB in Schritten von 001 dB ausgewaumlhlt werden Ein Anstieg von 6 dB ist fast gleich eine Verdoppelung in linearer Skala des Spannungswertes des SignalsBei einer Staumlrke von 0 dB wird das Signal verstaumlrkt waumlhrend es ein einer Staumlrke von weniger als 0 dB abgeschwaumlcht wird
c) VERZOumlGERUNG DES SIGNALS (DELAY)Das wiedergegebene Audio-Signal kann verzoumlgert werden um die akustische Ausrichtung zu erlauben Dies gleicht die verschiedenen Positionen der Lautsprecher bei der Installation und Klangwiedergabe aus und wird in mS ausgedruumlckt Der Parameter kann zwischen 00 mS und 729 mS in Schritten von 01mS ausgewaumlhlt werden
Um ein Audiosignal auszurichten kann folgende Formel benutzt werden
Verzoumlgerung = GAPx1000)344
Verzoumlgerung = mS (in Millisekunden ausgedruumlckt)GAP = Abstand des Lautsprechers vom Referenzpunkt (in Metern ausgedruumlckt)Klanggeschwindigkeit = 344 ms
d) MUTEJeder einzelne Kanal kann auf Mute gestellt werden Derselbe Befehl kann im Fenster des Menuumls Meters aktiviert werden PS Die al lgemeine Stummschaltung hat eine houmlhere Priori taumlt als die Stummschaltung der einzelnen Kanaumlle
e) PHASEErlaubt die Phasenrotation um 180deg zum EingangssignalDiese Rotation erlaubt vor Allem die Optimierung der niederen Frequenzen bei komplexen Installationen
f) ENTZERRUNGENDieser Befehl oumlffnet das Menuumlfenster fuumlr die Entzerrung des einzelnen Kanals Er wird vor Allem benutzt um eine oder mehrere Frequenzen zu korrigieren die gedaumlmpft oder verstaumlrkt werden muumlssen
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
35
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
36
AC26N verwaltet 12 Filter fuumlr jeden einzelnen Ein- und Ausgangskanal mit drei verschiedenen Konfigurationen- Equalizer PEQ (peaking equalizer) ist ideal um nur ein bestimmtes Frequenzband
zu identifizieren zu isolieren und zu korrigieren Es gehen alle Frequenzen durch aber nur die um die mittlere Frequenz steigt und sinkt um eine bestimmte Bandbreite und eine bestimmte Staumlrke
- Equalizer High-Shelf geht alle Frequenzen durch aber die Frequenzen uumlber der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
- Equalizer Low-Shelf geht alle Frequenzen durch aber die Frequenzen unter der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
f Nummerierung der 12 verfuumlgbaren Filter fuumlr diesen Ein- oder Ausgang1
f2 Es wird der Filtertyp angezeigt
Dis Ausgeschaltet (nicht vorhanden)
PEQ Peaking equalizer
Sh H Filter High-Shelf
Sh L Filter Low-shelf
Beispiele PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
ANMERKUNGDer Parameter Bw legt das Frequenzfeld neben der eingestellten Frequenz fest wo der Filter aktiviert wird je houmlher der Bw-Wert desto houmlher das Frequenzfeld (1Bw=1 Oktave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filter High-Shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filter Low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) KOMPRESSIONDieser Befehl oumlffnet das Menuumlfenster fuumlr die Kompression des einzelnen Kanals
g1) TresholdIdentifiziert die Schwelle an der das Kompressionsverhaumlltnis beginnt Der Basiswert 11
g2) RatioIdentifiziert das Kompressionsverhaumlltnis zwischen dem Ein- und Ausgangssignal
g3) Post Gain Attach Release HoldDiese Daten entsprechen dem Kompressionsverhaumlltnis das man erreichen moumlchte
Post Gain ist der Gewinn am AusgangAttack ist die Anschlusszeit Release ist die ReleasezeitHold ist die Beibehaltungszeit
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
BESCHREIBUNG DES MENUumlFENSTERS Preset
Dieses Fenster erlaubt bis zu 32 Konfigurationen im AC26N zu speichernDer Hersteller liefert das System mit einem voreingestellten Programm das auf Position 0 gespeichert ist und nicht uumlberschrieben werden kann
032 Es zeigt die Lokalisierung der Speicherung der KonfigurationDiese Nummer erscheint auch im Fenster Meters auf der Position (g) Das benutzte Programm kann jederzeit vom Benutzer angezeigt werden
Empty Preset Es ist der Name der der Nummer der Lokalisierung zugeordnet wird wenn keine Einstellung gespeichert ist (leer)
Local preset Es i s t de r Name de r de r Nummer de r Loka l i s i e rung zugeordnet wird wenn eine Konfiguration gespeichert wird
ANMERKUNG = Man kann eine Einstellung mit dem gewuumlnschten Namen mit max 16 Buchstaben nur speichern wenn man die Schnittstelle uumlber den Computer benutzt
Bei der Wahl eines Programms erscheint folgendes Fenster
Anzeige des Namens der dem Programm zugeordnet istUm auf die Anwendung einzuwirken stehen 3 Auswahlmoumlglichkeiten zur Verfuumlgung
Das Programm wird im Speicher des AC 26N gespeichert
Das Programm wird geloumlscht
Das Programm wird geladen und ist bereit fuumlr die Benutzung
Save
Del
Load
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
37
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
38
BESCHREIBUNG DES MENUumlFENSTERS X-Over
Dieses Fenster erlaubt fuumlr jeden Ausgang einen Bassdurchgangsfilter einen Hochdurchgangsfilter oder mittels Kombination von beiden einen Banduumlbergangsfilter zu waumlhlenDer Filter ist ein Linkwitz-Riley wo man die Neigung von 12 dBoct 24dBoct oder 48 dBoct und die entsprechende Schnittfrequenz auswaumlhlen kann
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) AUSGANGSKANAumlLE
Die Steckverbinder am Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) FILTER CROSSOVERDen Filter nach Bedarf waumlhlen Man kann folgendes auswaumlhlen
Dis Kein Filter aktiviert
HP Hochdurchgangsfilter nur den Teil des Audiosignals durchlassen der uumlber der Schnittfrequenz liegt
LP Bassdurchgangsfilter nur den Teil des Audiosignals durchlassen der unter der Schnittfrequenz liegt
Filter-Konfiguration Tiefpass Hochpass
Nichts Dis Dis
Hochpass HP Dis
Tiefpass Dis LP
Bandpass HP LP
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
c) DAumlMPFUNGSNEIGUNGDie Daumlmpfungsneigung des Audiosignals auf der Basis der Verringerung auswaumlhlen die man erreichen moumlchte Je houmlher die Daumlmpfungsneigung bei gleicher Schnittfrequenz desto groumlszliger ist die Signalauswahl Man kann folgendes waumlhlen
12 entsprechend 12 dboct
24 entsprechend 24 dboct
48 entsprechend 48 dboct
d) SCHNITTFREQUENZErlaubt die Durchgangsfrequenz der niederen Frequenzen (Bassdurchgangsfilter) oder der hohen Frequenzen (Hochdruchgangsfilter) einzustellenDie Auswahl des Schnitts bezieht sich auf die Wiedergabe die man erreichen moumlchteDie benutzte Maszligeinheit ist Hz
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
BESCHREIBUNG DES MENUumlFENSTERS Matrix
Erlaubt fuumlr jeden Ausgang das Eingangssignal zu waumlhlen das als Quelle benutzt werden soll
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) AUSGANGSKANAumlLEIdentifizierung des einzustellenden Ausgangskanals
b) IDENTIFIZIERUNG DER EINGAumlNGEDen Signaltyp auswaumlhlen der nach eigener Anforderung jedem einzelnen Ausgang zugeordnet werden soll Man kann folgendes waumlhlen
In A Das Signal wird dem Eingang A zugeordnet
In B Das Signal wird dem Eingang B zugeordnet
In A+B Zuordnung der a lgebra ischen Summe der be iden Eingangssignale A und B
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
BESCHREIBUNG DES MENUumlFENSTERS Option
Erlaubt die Anzeige der Systemeinstellungen wie die Zuordnung der Ein- und Ausgaumlnge Daumlmpfung Displaykontrast und Firmware-Version
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B Src
Diese Option erlaubt die Einstellung des Audio-Signaltyps am Eingang
Analoge Audiosignale (Eingaumlnge A und B)
Digitale Audiosignale (Eingang AESEBU)
DigOut Src
An In =Audiosignale an den analogen Eingaumlngen
Dig In =Audiosignale am digitalen Eingang
OUT 1-2 =Audiosignale an den Ausgaumlngen 1 und 2
OUT 3-4 =Audiosignale an den Ausgaumlngen 3 und 4
OUT 5-6 =Audiosignale an den Ausgaumlngen 5 und 6
Input Mode
An In
Dig In
Indip =
Linked =
Diese Option erlaubt die Audioquelle zu waumlhlen die fuumlr den Steckverbinder AESEBU OUT (digitaler Ausgang) bestimmt ist
Erlaubt die Eingaumlnge zu konfigurieren
Sie sind unabhaumlngig und selbststaumlndig sie unterliegen keinen Verpflichtungen untereinander Sie sind verbunden und funktionieren im Stereo-Modus
Die Kompressoren Filter Verzoumlgerungen die Lautstaumlrke sind bei beiden Kanaumllen identisch
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
39
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
40
Atten PadZeigt an wie der Wahlschalter -6 dB auf der Ruumlckseite eingestellt ist [Ref 5] Dieser Wahlschalter muss aktiviert werden wenn das Level an den analogen Eingaumlngen zu hoch ist Der Wahlschalter wird uumlber die Taste aktiviert im Menuuml gibt es nur eine Anzeige
0dB = Wahlschalter nicht aktiviert
-6dB = Wahlschalter aktiviert
Contrast
10 heller 60 dunkler 100
Fw Vers
Die Eingangssignale sind dieselben wie die Eingangsquelle
Die Eingangssignale werden vom internen Prozessor um -6 dB gedaumlmpft
Erlaubt den Kontrast des LCD-Displays einzustellen um den Unterschied der Helligkeit auf den Installationsort auszurichten Ein deutlicheres Display erlaubt auf korrekte und schnelle Weise innerhalb der Menuumls zu surfenDie Hersteller-Einstellung am Ausgang liegt bei 60
Zeigt die Firmware-Version des Prozessors an
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
41
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
42
TECHNISCHE DATEN
Antwort in FrequenzDynamische GammaCMMRCrosstalkDistorsion
ProzessorFrequenz der DatenausarbeitungAnaloge Converter Verzoumlgerung der VerteilungSpeicherung der Konfigurationen
DisplayTastenBedienungen
Analoger Eingang ndeg2 x XLR (3-poliger Female Stecker)Impedanz des Eingangs gt10KOhmMaximales Level +21dBu ohne PAD
+27dBu bei PAD
Impedanz des Ausgangs 50OhmMaximales Level +21dBu Typ symmetrisch
Typ SPDIF-AESEBU (AES3)
Typ Entsprechend dem Standard des Eingang
Typ
Typ
NETZSPANNUNGABMESSUNGEN (BXHXT)GEWICHT
AUDIO-LEISTUNGEN+- 01dB (20 to 30kHz)116dB typgt 60dB (50 to 10kHz)lt -100dB0002 (1kHz +4dBu)
DIGITALE AUDIO-LEISTUNGEN DSP 2856-bit 48KHz24-bit BURR BROWN15ms32 preset
KONTROLLEN LCD GrafikESC - MENU - FUNCTIONS SELECTIONENTER
EIN-AUSGAumlNGE
Analoger Ausgang ndeg6 x XLR (3-poliger Male Stecker)
Digitaler Eingang ndeg1x XLR (3-poliger female Stecker)
Digitaler Ausgang ndeg1x XLR (3-poliger Male Stecker)
Ein-Ausgang Rdnet ndeg2 x XLR RJ45 (kabel CAT 5) USB Typ B
KONTROLLPARAMETER AUDIOStaumlrke -80dB a +20dB step 01dBVerzoumlgerung Eingang 0 a 729mS step 01 mS
Ausgang 0 a 340mS step 01mSPhasenrotation 0deg - 180deg
KOMPRESSIONSchwelle -80dB a +20dB step 01dBVerhaumlltnis 11 a Inf1 step 001Staumlrke am Ausgang 0dB a 40dB step 01dBAnschlusszeit 1mS a 1000mS step 01mSReleasezeit 1mS a 1000mS step 01mSBeibehaltungszeit 1mS a 1000mS step 01mS
EQUALIZER12 Equalizer fuumlr jeden Ein- und Ausgang
PEQ (parametrischer) Hi-shelf Lo-sheftFrequenz 20Hz a 20KHz step 1HzStaumlrke -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (lediglich PEQ)
FILTER CROSSOVERFilter Linkwitz Riley
HP HochdurchgangsfilterLP Bassdurchgangsfilter
Neigung 12dBoct - 24dBoct - 48dBoctSchnittfrequenz 5Hz a 20KHz step 1Hz
Full-range 100-240Vac 50-60Hz430482x43x130mm 19Kg
AnmerkungenSpezifikationen unterliegen Aumlnderungen ohne Vorankuumlndigung
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
INTRODUCTIONAC26N est un processeur audio numeacuterique pour la gestion de leacutequipement audio conccedilu pour des installations fixes et mobiles Il fonctionne selon une technologie de pointe avec des processeurs agrave 2856bits et des convertisseurs ADDA agrave 24-bits hautes performances Les fonctions du processeur sont les niveaux dentreacutee et de sortie le deacutelai (delay) la polariteacute 12 bandes deacutegalisation par canal dentreacutee et de sortie diffeacuterentes seacutelections de croisement (crossover) et un limiteur hautes performances Le controcircle des filtres a une reacutesolution de 1Hz Les entreacutees et les sorties peuvent ecirctre programmeacutees en plusieurs configurations pour satisfaire tous les besoins AC26N peut ecirctre controcircleacute en temps reacuteel et tous les paramegravetres peuvent ecirctre configureacutes depuis le pupitre frontale et par ordinateur avec interface graphique intuitive accessible via le logiciel laquoDVA Networkraquo et une connexion de reacuteseau deacutedieacutee RDnet ou USBLa mise agrave jour du logiciel pour lUniteacute centrale et DSP par ordinateur portable permet de maintenir le dispositif actualiseacute Il est possible denregistrer et de rappeler 32 configurations preacute-eacutequipeacutees de configuration
Contenu de lemballage - AC26N - Mode demploi- CD logiciel- Cacircble dalimentation
Caracteacuteristiques- 2 entreacutees et 6 sorties avec adressage flexible- Entreacutee et sortie steacutereacuteo AESEBU adressables - DSP 2856-bit- Convertisseurs AD BURR BWOWN 24-bit hautes performances- Freacutequence de reacutesolution des filtres 1 Hz - 12 eacutegaliseurs parameacutetriques pour chaque entreacutee et sortie- 2 filtres de croisement par sortie avec pente seacutelectionnable agrave 122448dBoct- DRC agrave configuration multiple hautes performances pour configuration limiteur
compression pour chaque entreacutee et sortie- Niveau reacuteglable en dB polariteacute et deacutelai pour chaque entreacutee et sortie- Mise agrave jour du micrologiciel par lordinateur- Affichage graphique agrave cristaux liquides- 32 preacutereacuteglages enregistrables par lutilisateur- Interface USB pour le controcircle et la configuration par ordinateur- Interface RDnet permettant de controcircler jusquagrave 256 dispositifs agrave distance
PC
PC
RDNETcontrol(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FONCTIONS DE LA FACE AVANT
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
COMMANDES ET FONCTIONS1) AFFICHAGE
Laffichage graphique agrave cristaux liquides permet de visualiser et deacutediter les informations de lAC26N sans utiliser lordinateur Le contraste peut ecirctre configureacute dans le menu principal
2) MANETTE Functions Selector et Push EnterCe controcircle permet de se deacuteplacer de seacutelectionner et de modifier les paramegravetres dans les menus affichables agrave leacutecranRotation de la manette (Functions Selectors)- permet de se deacuteplacer sur les diffeacuterentes pages du menu - permet de modifier les paramegravetres seacutelectionneacutesPression de la manette (Push Enter)- permet de seacutelectionnervalider les paramegravetres
3) Bouton ESC Ce controcircle permet de quitter les menus afficheacutes ou de revenir agrave la visualisation preacuteceacutedente
4) Bouton Menu Ce controcircle permet dacceacuteder directement au menu principal
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
Fra
nccedilais
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
43
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
Fra
nccedilais
44
DVA Network
AC26N est eacutequipeacute dune interface de reacuteseau proprieacutetaire deacutenommeacutee RDNET au moyen de laquelle il est possible de sinterfacer agrave lordinateur agrave travers un peacuteripheacuterique (RDNET control)
Pour cela un protocole de communication a eacuteteacute deacuteveloppeacute avec lequel il est possible de recevoir et denvoyer les donneacutees ce branchement permet de faire le monitorage en temps reacuteel des paramegravetres du diffuseur comme puissance de sortie tempeacuterature de lamplificateur eacutetat du limiteur etc Il est aussi possible de seacutelectionner diffeacuterentes eacutegalisations ou den creacuteer de nouvelles et de reacutegler les niveaux de volume souhaiteacutes au moyen dun plug-in approprieacute
On conseille de teacuteleacutecharger gratuitement le logiciel DVA Network directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
DVA USB Manager
On conseille de teacuteleacutecharger gratuitement le logiciel DVA USB Manager directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
Le micrologiciel du module amplificateur peut ecirctre remis agrave jour par le port USBPour rendre cette mise agrave jour possible et facile un programme speacutecifique a eacuteteacute deacuteveloppeacute
DOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
CONNEXIONS DU PANNEAU ARRIEgraveRE
1586 75 141210 11 13 169 17
14) Connecteur ldquo USBrdquoCe connecteur USB (type B) permet de connecter le processeur agrave un ordinateur pour le controcircle et la mise agrave jour du micrologiciel via un programme deacutedieacute (DVA Network)
15) PRISE DALIMENTATION MAINSPermet la connexion du cacircble dalimentation fourni de seacuterie
16) PORTE-FUSIBLE FUSELogement pour fusible de ligne
17) INTERRUPTEUR GENERAL POWERLinterrupteur permet de mettre en marche ou deacuteteindre le controcircleur audio
COMMANDES ET FONCTIONS
5) SELECTEUR ldquo-6dBrdquoLe seacutelecteur permet de reacuteduire de 6dB les niveaux dentreacutee analogiques XLR [6] tout en compensant les niveaux eacuteleveacutes de sortie des meacutelangeurs ou dautres dispositifs audio Quand la barre du niveau de signal des entreacutees sur laffichage [1] reste au maximum cela indique que le niveau du signal entrant est eacuteleveacute Il est alors conseilleacute dutiliser latteacutenuation -6dBIl est possible de veacuterifier quand le seacutelecteur est activeacute par le menu Option
6) CONNECTEURS DENTREE ldquoArdquo ET ldquoBrdquoEntreacutees eacutequilibreacutees au niveau de la ligneIls sont en mesure daccepter des connecteurs XLR macircles
7) CONNECTEURS DE SORTIE ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo ET ldquo6rdquoSorties eacutequilibreacutees au niveau de la ligne Ils sont en mesure daccepter des connecteurs XLR femelles
Prendre garde agrave brancher convenablement les sorties sur les diffuseurs ou les amplificateurs en fonction des configurations de chaque canal pour eacuteviter des deacutegacircts et des problegravemes de fonctionnement
Section ldquoAESEBUrdquo
8) CONNECTEUR DENTREE INOutre les entreacutees audio analogiques une entreacutee audio numeacuterique SPDIF-AESEBU (AES3) a eacuteteacute preacutevue et peut ecirctre seacutelectionneacutee par le menu de setupLentreacutee requiert une connexion eacutequilibreacutee en utilisant un connecteur XLR avec un cacircble agrave 3 conducteurs de 110ohm torsadeacute
9) CONNECTEUR DE SORTIE OUTCe connecteur permet de relancer le signal audio dans les entreacutees analogiques ou numeacuteriques ou sur les sorties La source doit ecirctre reacutegleacutee par le menu OptionLa connexion sera conforme agrave la mecircme norme que lentreacutee [reacutef8]
Section ldquoRDNETrdquo
10) CONNECTEUR DENTREE DATA INPUTConnecteur RJ45 entreacutee de donneacutees
11) CONNECTEUR DE SORTIE DATA LINKConnecteur RJ45 sortie de donneacutees pour la connexion de seacuterie en cascade
12) VOYANT LUMINEUX ONCe voyant de couleur verte sallume uniquement quand lAC26N a reconnu et est connecteacute agrave luniteacute principale RDNET par lordinateur
13) VOYANT LUMINEUX ACTIVECe voyant de couleur jaune clignote quand une transmission des donneacutees est active entre RDNET et le dispositif
PUSH
P SHU
SHPU
P SHU
PUSH
CONNEXIONS
Audio analogiquesLes connexions eacutequilibreacutees permettent de reacuteduire au minimum le bruit provoqueacute par les cacircbles et dutiliser de longs cacircblesCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLe connecteur XLR doit ecirctre brancheacute avec la broche 1 agrave la masse la broche 2 au chaud (+) et la broche 3 au froid (-) En cas de cacircble blindeacute brancher le blindage agrave la broche 1Les cacircbles de connexion XLR-XLR et XLR-Jack14(63mm) peuvent semployer pour la connexion agrave lAC26N
12
3
Entreacutee
Entreacutee
XLR - femme
XLR - femme
1 2
3
Sortie
Sortie
XLR - Macircle
XLR - Macircle
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2 = Point chaudPhase +VE
Broche 3 =Point froidPhase -VE
Broche 3 =Point froidPhase -VE
Anneau
Manchon
Pointe Point chaudPhase +VE
Anneau = Point froidPhase -VE
ManchonB Masselindeacute
Pointe
Les connexions deacuteseacutequilibreacutees peuvent semployer mecircme si le bruit provoqueacute par les cacircbles augmente Les cacircbles ne peuvent deacutepasser 5m de longCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLes connexions deacuteseacutequilibreacutees peuvent abaisser le niveau du signal entrant de 6dB Pour remeacutedier agrave cet inconveacutenient il faut brancher la broche 3 agrave la masse mecircme si cela augmente le bruit
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
45
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
46
12
3
1 2
3
Pointe Manchon
Pointe = Signal
Broche 3 = Link to Pin 1
Broche 3 = Link to Pin 1
ManchonB Masselindeacute
Audio numeacuteriques (AESEBU)
AESEBU (protocole AES3) est une entreacutee eacutequilibreacutee isoleacutee eacutelectriquement agrave laide dun transformateur Elle permet demployer deux canaux audio dans un seul cacircble bipolaire blindeacute Les caracteacuteristiques du cacircble doivent ecirctre de 3 pocircles impeacutedance 100ohm torsadeacute et blindeacute avec connecteur XLR (AES3 standard)
RJ 45
|1|2|3|4|5|6|7|8|
RDnet
Chaque port RDNet des Control 2 et Control 8 peut ecirctre brancheacute agrave un maximum de 32 dispositifs compatibles placeacutes en cascade Dans lexemple suivant le port de luniteacute de controcircle RDNET CONTROL 2 est relieacute agrave lentreacutee DATA INPUT dun AC26N dont la sortie parallegravele DATA LINK est envoyeacutee agrave lentreacutee de lAC26N successif Dans lexemple [n] est un nombre compris entre 3 et 32 (limite maximale des dispositifs que lon peut relier agrave un sous-reacuteseau)
La longueur totale du cacircble CAT5 dun sous-reacuteseau NE peut PAS deacutepasser 900 megravetres
Le connecteur doit ecirctre relieacute comme 1 ndash disponible pour dautres fonctions (par exemple audio +) 2 ndash disponible pour dautres fonctions (par exemple audio )3 ndash disponible pour dautres fonctions (par exemple masse analogique)4 ndash masse numeacuterique5 ndash masse numeacuterique6 ndash disponible pour dautres fonctions (par exemple alimentation)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
MISE EN MARCHE
Lors de la mise en marche du dispositif linitialisation deacutebute et dure quelques secondes Leacutecran affiche le modegravele le logo et la barre de progression du chargement du programme
En fin de processus dinstallation leacutecran affiche la fenecirctre du menu Meters Pour connaicirctre les indications en deacutetail consulter le paragraphe DESCRIPTION FENETRE MENU Meters
LAC26N est precirct agrave lemploi
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION ET VISUALISATION
Pour entrer dans la fenecirctre du menu principal il faut pousser sur la touche MENU ( ) agrave lavant du dispositifDune page quelconque du menu en poussant sur la touche ESCrdquo ( ) on revient automatiquement sur la page-eacutecran preacuteceacutedente
MENU PRINCIPAL
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Le processeur contient six menus Ils montrent etou configurent les paramegravetres du systegravemeLes menus principaux sont
Meters Visualisation des niveaux des entreacutees et des sorties visualisation du programme utiliseacute et eacutetat mute rapide
Preset Meacutemoriser enregistrer et eacuteliminer les configurations du systegraveme
Matrix seacutelectionner les sorties en fonction du signal entrant
Ch Job configuration de chaque signal
X-Over configurer les freacutequences de coupure et les types de filtres pour chaque sortie
Option attribution des entreacutees et des sorties contraste daffichage la version du micrologiciel les entreacutees et dautres options
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
47
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
48
DESCRIPTION DE LA FENETRE MENU Metersrdquo
Cette fenecirctre permet de visualiser les configurations et leacutetat geacuteneacuteral des entreacutees et des sorties la version du programme utiliseacute son eacutetat et le mode de pilotage du systegraveme
Les menus et les options afficheacutees peuvent se seacutelectionner en tournant la manette ldquoFUNCTIONS SETECTORrdquo ( ) Pour avoir accegraves agrave linteacuterieur de la seacutelection il faut mettre le paramegravetre souhaiteacute en eacutevidence et pousser sur la manette ldquoPush Enterrdquo ( | ) Il faut en faire de mecircme pour seacutelectionner etou modifier les options dans les commandes du menu
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositifAvec des signaux dentreacutee numeacuteriques les indications ldquoArdquo et ldquoBrdquo correspondent agrave lentreacuteeEn tournant la manette ldquoFUNCTIONS SELECTORrdquo [2] on fait deacutefiler en mode cyclique les canaux dentreacutee de sortie et lindication de mute geacuteneacuteral (d) le canal seacutelectionneacute est mis en eacutevidence
b) BARRE DE NIVEAU DE COMPRESSIONMUTE CANAL
COMPRESSION DE SIGNALLa compression du signal est visualiseacutee par le deacutefilement de la barre de droite de haut en bas
MUTE Chaque canal peut ecirctre placeacute en mute Seacutelectionner le canal et pousser sur la manette ldquoPush Enterrdquo [2] pour valider le changement deacutetat Lindication du canal sera remplaceacutee par la lettre M et la barre sera totalement mise en eacutevidencePour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterations
c) BARRE DE NIVEAU DE SIGNALLindication du niveau de chaque canal est signaleacutee par le deacutefilement de la barre de gauche
d) MUTE GENERALIl est possible de mettre simultaneacutement toutes les entreacutees et les sorties en mute Tourner la manette ldquoFUNCTIONS SELECTORrdquo seacutelectionner la lettre M et pousser sur la manette Push EnterPour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterationsLe mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) MODES DE COMMANDEIl affiche le mode dutilisation etou les dispositifs qui sont relieacutes agrave lAC26N
Local = utilisation autonome Aucune connexion agrave un dispositif exteacuterieur
NET = relieacute directement au reacuteseau deacutedieacute RDNet et agrave lordinateur
USB = relieacute directement agrave un ordinateur par cacircble USB
f) INDICATION DETAT DE PARAMETRAGECette indication permet de constater si un ou plusieurs paramegravetre(s) du programme chargeacute aont eacuteteacute modifieacute(s) par rapport au dernier sauvetage
= programme dorigine
= programme avec des paramegravetres modifieacutes
g) PROGRAMME CONFIGURELe chiffre indique le programme chargeacute et utiliseacute par le systegraveme agrave lemplacement de sauvetage Consulter le menu de Preset pour de plus amples deacutetails
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
DESCRIPTION DE LA FENETRE MENU Ch Job
Cette fenecirctre permet dafficher la configuration de chaque canal
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) NIVEAU DU SIGNALIndique le gain du signal Laugmentation de lintensiteacute dun signal est libelleacutee en deacutecibel (dB) Le paramegravetre peut ecirctre seacutelectionneacute de -8000dB agrave +2000dB avec des pas de 001dB Une augmentation de 6dB est eacutegale approximativement au redoublement agrave leacutechelle lineacuteaire du niveau du signal sous tensionAvec un gain supeacuterieur agrave 0dB le signal est amplifieacute tandis quavec un gain infeacuterieur agrave 0dB le signal est atteacutenueacute
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
49
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
50
c) DELAI DU SIGNAL (DELAY)Le signal audio reproduit peut ecirctre retardeacute pour permettre lalignement acoustique Cela compense les diffeacuterentes positions des diffuseurs pendant linstallation et la reproduction sonore Il se libelle en mS Le paramegravetre peut ecirctre seacutelectionneacute de 00mS agrave 729mS avec un pas de 01mSPour aligner un signal audio il est possible dutiliser la formule suivante
Deacutelai = (GAPx1000)344
Deacutelai = ms (en millisecondes)GAP = distance du diffuseur du point de reacutefeacuterence (en megravetres)Vitesse du son = 344ms
d) MUTEChaque canal peut ecirctre placeacute en mute La mecircme commande peut ecirctre activeacutee dans la fenecirctre du menu meters NB Le mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) PhasePermet la rotation de phase de 180deg par rapport au signal entrantCette rotation permet loptimisation surtout des basses freacutequences dans les installations complexes
f) EGALISATIONCette commande ouvre la fenecirctre du menu deacutegalisation de chaque canal Elle sert surtout pour corriger une ou plusieurs freacutequences qui doivent ecirctre atteacutenueacutees ou augmenteacutees
M M
LAC26N gegravere 12 filtres par canal dentreacutee et sortie avec trois types de configurations diffeacuterentes - Leacutegaliseur PEQ (peaking equalizer) est ideacuteal pour identifier isoler et
corriger une seule plage de freacutequences bien deacutetermineacutee Toutes les freacutequences passent mais il augmente ou diminue uniquement celles autour de la freacutequence centrale pour une bande preacutecise et un gain deacutefini
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessus de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessous de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
f Numeacuterotation des 12 filtres disponibles pour cette entreacutee ou cette sortie1
f Le type de filtre est afficheacute 2
Dis Deacutesactiveacute (absent)
PEQ Peaking equlizer
Sh H Filtre high-shelf
Sh L Filtre high-shelf
Exemples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
REMARQUELe paramegravetre Bw deacutetermine le champ de freacutequences adjacent agrave la freacutequence configureacutee ougrave est activeacute le filtre Plus la valeur Bw est eacuteleveacutee plus vaste est le champ de freacutequences (1Bw=1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONCette commande ouvre la fenecirctre du menu de compression de chaque canal
g1) TresholdIdentifie le seuil ougrave commence le rapport de compression La valeur de base 11
g2) RatioIndique le rapport de conversion entre le signal entrant et le signal sortant
g3) Post Gain Attach Release HoldCes donneacutees deacutependent du rapport de conversion que lon veut obtenir - Post Gain est le gain de sortie- Attack est le temps dattaque - Release est le temps de relacircchement- Hold est le temps de maintien
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
52
DESCRIPTION DE LA FENETRE MENU Preset
Cette fenecirctre permet de meacutemoriser jusquagrave 32 configurations dans lAC26NLe fabricant fournit le systegraveme avec un programme configureacute et enregistreacute en position 0 et non susceptible deacutecrasement
032 Elle indique lemplacement de sauvetage de la configurationCe numeacutero apparaicirct dans la fenecirctre Meters en position (g) A tout moment le programme utiliseacute peut ecirctre afficheacute par lutilisateur
Empty Preset Cest le nom qui est associeacute au numeacutero de lemplacement quand aucune configuration (vide) nest enregistreacutee
Local preset Local preset est le nom qui est associeacute au numeacutero de lemplacement quand on enregistre une configuration NB = Il est possible denregistrer une configuration avec lenom souhaiteacute de 16 lettres tout au plus agrave condition que lonutilise linterface via lordinateur
Le nom du programme assigneacute est indiqueacutePour toucher agrave lapplication 3 choix soffrent agrave vous
Save Le programme est enregistreacute en meacutemoire de lAC26N
Del Le programme est effaceacute
Load Le programme est chargeacute et precirct agrave lemploi
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
51
DESCRIPTION DE LA FENETRE MENU X-Over
Cette fenecirctre permet de seacutelectionner un filtre passe bas un filtre passe haut ou par la combinaison des deux de creacuteer un filtre passe bande pour chaque sortieLe filtre actif est un Linkwitz-Riley qui permet de seacutelectionner la pente de 12dBoct 24dBoct ou 48dBoct et sa freacutequence de coupure
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) CANAUX DE SORTIE
Les connecteurs de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) FILTRE CROSSOVERSeacutelectionner le filtre selon les besoins Il est possible de seacutelectionner
Dis Aucun filtre activeacute
HP Filtre passe-haut laisse passer uniquement la partie de signal audio supeacuterieure agrave la freacutequence de coupure
LP Filtre passe-bas laisse passer uniquement la partie de signal audio infeacuterieure agrave la freacutequence de coupure
Configuration du filtre Passe-haut Passe-bas
Rien Dis Dis
Passe-haut HP Dis
Passe-bas Dis LP
Passe-bande HP LP
12dBoct
24dBoct
Hz
dB
Ga
in 48dBoct
12dBoct
24dBoct
Hz
dB
Ga
in
48dBoct
c) PENTE DATTENUATIONSeacutelectionner la pente datteacutenuation du signal audio en fonction de la diminution que lon veut obtenir Plus la pente datteacutenuation est eacuteleveacutee agrave eacutegaliteacute de freacutequence de coupure plus eacuteleveacutee sera la seacutelection du signal Il est possible de seacutelectionner
12 correspond agrave 12dboct
24 correspond agrave 24dboct
48 correspond agrave 48dboct
d) FREQUENCE DE COUPUREElle permet de reacutegler la freacutequence de passage des freacutequences infeacuterieures (filtre passe-bas) ou des freacutequences supeacuterieures (filtre passe-haut) uniquementLe choix de la coupure deacutepend de la reproduction que lon veut obtenirLuniteacute de mesure utiliseacutee est lHz
Hz
Hz
dB
dB
Ga
in
f0
f0
0dB0dB
0dB
-6dB
freacutequence
freacutequence
freacutequence
freacutequence
Ga
in
f0
0dB
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
53
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
54
DESCRIPTION DE LA FENETRE MENU Matrix
Elle permet de seacutelectionner le signal entrant agrave utiliser comme source pour chaque sortie
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) CANAUX DE SORTIEIdentification du canal sortant agrave reacutegler
b) IDENTIFICATIONS DES ENTREESSeacutelectionner le type de signal agrave associer agrave chaque sortie en fonction des besoins Il est possible de seacutelectionner
In A Le signal entrant A est associeacute
In B Le signal entrant B est associeacute
In A+B La somme algeacutebrique des deux signaux entrants A et B est associeacutee
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
DESCRIPTION DE LA FENETRE MENU Option
Permet dafficher les reacuteglages du systegraveme comme lassignation des entreacutees et des sorties latteacutenuation le contraste de laffichage et la version du logiciel
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcCette option permet de reacutegler le type de signal audio entrant
An In =signaux audio analogiques (entreacutees ldquoArdquo et ldquoBrdquo)
Dig In =signaux audio numeacuteriques (entreacutee AESEBU)
DigOut SrcCette option permet de seacutelectionner la source audio qui sera adresseacutee sur le connecteur AESEBU OUT (sortie numeacuterique)
An In = signaux audio des entreacutees analogiques
Dig In =signaux audio sur lentreacutee numeacuterique
OUT 1-2 = signaux audio sur les sorties 1 et 2
OUT 3-4 = signaux audio sur les sorties 3 et 4
OUT 5-6 = signaux audio sur les sorties 5 et 6
Input ModePermet de configurer les entreacutees
Indip = sont indeacutependantes et autonomes Ne sont soumises agrave aucun type de lien
Linked = sont unies et fonctionnent en mode steacutereacuteo Les compresseurs les filtres les deacutelais le volume sont identiques pour les deux canaux
Atten PadIndique le mode de reacuteglage du seacutelecteur ldquo-6dBrdquo placeacute agrave larriegravere [reacutef 5] Il faut activer ce seacutelecteur quand les niveaux dentreacutee analogiques sont trop eacuteleveacutes Le seacutelecteur sactive uniquement par le bouton Dans le menu il sagit dune simple visualisation
0dB = seacutelecteur non activeacute Les signaux dentreacutee sont identiques agrave la source entrante
-6dB = seacutelecteur activeacute Les signaux entrants sont atteacutenueacutes de -6dB par le processeur interne
ContrastIl permet de reacutegler le contraste de laffichage agrave cristaux liquides pour compenser la diffeacuterence de luminositeacute avec le lieu dinstallation Une plus grande clarteacute de laffichage permet de naviguer convenablement et rapidement dans les menusLe reacuteglage agrave la sortie de lusine du fabricant est de 60
10 plus clair 60 plus fonceacute 100
Fw VersIndique la version du logiciel du processeur
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
55
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
56
DONNES TECHINIQUES
PERFORMANCES AUDIOReacuteponse en freacutequence +- 01dB (20 to 30kHz)Plage dynamique 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsion 0002 (1kHz +4dBu)
PERFORMANCES AUDIO NUMERIQUES Processeur DSP 2856-bit Freacutequence de traitement des donneacutees 48KHzConvertisseurs analogiques 24-bit BURR BROWNDeacutelai de propagation 15msMeacutemorisations des configurations 32 preset
CONTROLES Affichage LCD graficoBoutonsCommandes ESC - MENU - FUNCTIONS SELECTION
ENTERENTREESSORTIESEntreacutee analogique ndeg2 x XLR (3 broches femelle)
Impeacutedance dentreacutee gt10KOhmNiveau maximum +21dBu senza PAD
+27dBu con PADSortie analogique ndeg6 x XLR (3 broches macircle )
Impeacutedance de sortie 50OhmNiveau maximum +21dBuType Balanceacute
Entreacutee numeacuterique ndeg1x XLR (3 broches femelle)Type SPDIF-AESEBU (AES3)
Sortie numeacuterique ndeg1x XLR (3 broches macircle )Type conforme agrave la norme de lentreacutee
EntreacuteesSortie Rdnet ndeg2 x XLR RJ45 (cacircble CAT 5)USB Type B
PARAMETRES DE CONTROLE DU SONGain -80dB a +20dB eacutetape 01dBDeacutelai Entreacutee 0 a 729mS eacutetape 01 mS
Sortie 0 a 340mS eacutetape 01mSRotation de phase 0deg - 180deg
COMPRESSIONSeuil -80dB a +20dB eacutetape 01dBRapport 11 a Inf1 eacutetape 001Gain agrave la sortie 0dB a 40dB eacutetape 01dBTemps dattaque 1mS a 1000mS eacutetape 01mSTemps de relacircchement 1mS a 1000mS eacutetape 01mSTemps de maintien 1mS a 1000mS eacutetape 01mS
EGALISEURS12 eacutegaliseurs pour chaque entreacutee et sortieType PEQ (parameacutetrique) Hi-shelf Lo-sheft
Freacutequence 20Hz a 20KHz eacutetape 1HzGain -30dB a +15dB eacutetape 001dBBande 005dB a 2dB eacutetape 001dB (uniquement pour PEQ)
FILTRES CROSSOVERFiltre Linkwitz Riley
Type HF high-shelfLF low-shelf
Pente 12dBoct - 24dBoct - 48dBoctFreacutequence de coupure 5Hz a 20KHz eacutetape 1Hz
ALIMENTATION Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)POIDS 19Kg
Remarques Speacutecifications sujettes agrave modifications sans preacuteavis
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
2 VIE ATTIVO2 WAY ACTIVE
3 VIE PASSIVO3 WAY PASSIVE
L
L
A
A
HIGH L
MID L
LOW HIGHMID RHIGHMID L
LOW L
HIGH R
MID R
LOW R
R
R
B
B
1
1
2
2
3
3
456
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
Menu Matrix configurationMatrix
57 58
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
EROUIG ATRIX TNM
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
OU
TP
UT
1
OU
TP
UT
2
OU
TP
UT
3
OU
TP
UT
4
OU
TP
UT
5
OU
TP
UT
6
AE
S-E
BU
OU
TP
UT
INP
UT
A
AE
S-E
BU
INP
UT
INP
UT
B
D D D D D D
D D
A A A A A A
A SA
MP
LE
RA
TE
CO
NV
A
LIN
KA
BL
E
SC
HE
MA
A B
LO
CC
HI -
BL
OC
K D
IAG
RA
MB
LO
CK
SC
HA
LT
BIL
D -
SC
HE
MA
S F
ON
CT
ION
NE
LS
LINE ARRAY SUB MONO ATTIVO
LINE ARRAY SUB MONO ACTIVEINGRESSI - INPUT
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
L
L
L
A
A
A
AESEBU IN
AESEBU IN
AESEBU IN
AESEBU OUT
AESEBU IN
AESEBU IN
AESEBU OUT
R
R
R
LR
B
B
B
123456
HIGHMID L
HIGHMID L HIGHMID R
HIGHMID R
LOW L LOW R
LAYER
DISPLAY MEMORY
FADER MODE
LAYER
DISPLAY MEMORY
FADER MODE
Ingresso ANALOGICO
ANALOG Input
Collegamento in cascata
Link connections
Ingresso DIGITALE
DIGITAL inputA B
BALANCED AUDIO INPUTS
-6dB
PUSH PUSH
IN OUT
AES EBUPUSH
Oppure
or
Oppure
or
Menu Option configurationOption
Menu Option configurationOption Menu Option configurationOption
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type Analog
AES out An In
Input type Analog
AES out An In
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
59 60
InA-B Src Dig InInA-B Src Dig InInA-B Src An InInA-B Src An In
frequenzaHz
dB
Gu
ad
ag
no
60 200 2800
0dB0dB
-6dB
Esempio di un sistema a 3-vie
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
Out 1 Out 2 Out 3
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Esempio di un sistema a 3-vie
61 62
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
26NAC 26NAC
R TE
DO
R
MO LEU O R CE S
E O TR L A
S O
O C ND I P
P hsuernE t
o su cti nF nel rS e tc o
E CSME UN
IGCHTE OL SN EOBd
ocaL l
M
0
484
467
430
44
31
75
12
7
DIMENSIONI DIMENSIONSABMESSUNGEN DIMENSIONS
11
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
12
DESCRIZIONE FINESTRA MENUrsquo ldquoX-OverrdquoQuest a finestra permette di selezionare per ogni uscit a un filtro p assa basso un filtro p assa alto oppure tramite la combinazione di entrambe creare un filtro p assa bandaIl filtro presente egrave un Linkwitz-Riley dove egrave possibile selezionare la pendenza di 12dBoct 24dBoct oppure 48dBoct e la relativa frequenza di t aglio
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) CANALI USCITA
I connettori di uscita sono identificati utilizzando le medesime indicazioni presenti sulla serigrafia del retro del dispositivo
b) FILTRO CROSSOVERSelezionare il filtro a seconda delle necessitagrave Ersquo possibile selezionare
Dis Nessun filtro attivato
HP Filtro passa-alto lasciare passare solo la parte di segnale audio superiore alla frequenza di taglio
LP Filtro passa-basso lasciare passare solo la parte di segnale audio inferiore alla frequenza di taglio
Configurazione Filtro Passa basso Passa alto
Nessuna Dis Dis
Passa alto HP Dis
Passa basso Dis LP
Passa banda HP LP
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
c) PENDENZA DI ATTENUAZIONESelezionare la pendenza di attenuazione del segnale audio in base alla diminuzione che si desidera ottenere Piugrave elevata egrave la pendenza di attenuazione a paritagrave di frequenza di taglio maggiore egrave la selezione del segnale Ersquo possibile selezionare
12 corrisponde a 12dboct
24 corrisponde a 24dboct
48 corrisponde a 48dboct
d) FREQUENZA DI TAGLIOPermette drsquoimpostare la frequenza di passaggio delle sole frequenze inferiori (filtro passa-basso) o delle sole frequenze superiori (filtro passa-alto)La scelta del taglio egrave in funzione della riproduzione che si vuole ottenereLrsquounitagrave di misura utilizzata egrave Hz
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
DESCRIZIONE FINESTRA MENUrsquo ldquoMatrixrdquoPermette di selezionare per ogni uscita il segnale in ingresso da utilizzare come sorgente
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) CANALI USCITAIdentificazione del canale in uscita da impostare
b) IDENTIFICAZIONI INGRESSISelezionare il tipo di segnale da abbinare a ogni singola uscita in base alle proprie necessitagrave Ersquo possibile selezionare
In A Viene associato il segnale in ingresso laquoAraquo
In B Viene associato il segnale in ingresso laquoBraquo
In A+B Viene associato la somma algebrica dei due segnali in ingresso laquoAraquo e laquoBraquo
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
DESCRIZIONE FINESTRA MENUrsquo ldquoOptionrdquoPermette di visualizzare le impostazioni sistema come lrsquoassegnazione degli ingressi e delle uscite attenuazione il contrasto del display e la versione del firmware
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711
InA-B SrcQuesta opzione permette di impostare il tipo di segnale audio in ingresso
An In = segnali audio analogici (ingressi ldquoArdquo e ldquoBrdquo)
Dig In = segnali audio digitali (ingresso AESEBU)
DigOut SrcQuesta opzione permette di selezionare la sorgente audio che verragrave indirizzata sul connettore AESEBU OUT (uscita digitale)
An In = segnali audio presenti negli ingressi analogici
Dig In = segnali audio presenti sullrsquoingresso digitale
OUT 1-2 = segnali audio presenti sulle uscite 1 e 2
OUT 3-4 = segnali audio presenti sulle uscite 3 e 4
OUT 5-6 = segnali audio presenti sulle uscite 5 e 6
Input ModePermette di configurare gli ingressi
Indip = sono indipendenti ed autonomi non sono soggetti a vincoli di alcun genere tra di loro
Linked = sono uniti e funzionano in modalitagrave stereoI compressori i filtri i ritardi il volumesono identici per i due canali
13
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
14
Atten Pad
Indica come egrave impostato il selettore ldquo-6dBrdquo posto sul retro [rif 5] Ersquo necessario attivare questo selettore quando i livelli di ingresso analogici sono troppo elevati Il selettore viene attivato solo tramite il pulsante nel menugrave egrave solo una visualizzazione
0dB = selettore non attivatoI segnali di ingresso sono i medesimi della sorgente in ingresso
-6dB = selettore attivatoI segnali in ingresso vengono attenuati di -6dB dal processore interno
Contrast
Consente di regolare il contrasto del display LCD per compensare la differenza di luminositagrave con il luogo di installazione Una maggiore chiarezza del display permette di navigare allrsquointerno dei menugrave in modo corretto e veloceIl settaggio in uscita dalla ditta produttrice egrave 60
10 piugrave chiaro 60 piugrave scuro 100
Fw Vers
Indica la versione del firmware del processore
SPECIFICHE TECNICHE
PRESTAZIONI AUDIORisposta in frequenza +- 01dB (20 to 30kHz)Gamma dinamica 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsione 0002 (1kHz +4dBu)
PRESTAZIONI AUDIO DIGITALI Processore DSP 2856-bit Frequenza elaborazione dati 48KHzConvertitori analogici 24-bit BURR BROWNRitardo di propagazione 15msMemorizzazioni configurazioni 32 preset
CONTROLLI Diplay LCD graficoPulsantiComandi ESC - MENU - FUNCTIONS SELECTION
ENTER
INGRESSIUSCITEIngresso analogico ndeg2 x XLR (3 poli femmina)
Impedenza di ingresso gt10KOhmLivello massimo +21dBu senza PAD
+27dBu con PADUscita analogica ndeg6 x XLR (3 poli maschio)
Impedenza di uscita 50OhmLivello massimo +21dBu Tipo Bilanciato
Ingresso digitale ndeg1x XLR (3 poli femmina)Tipo SPDIF-AESEBU (AES3)
Uscita digitale ndeg1x XLR (3 poli maschio)Tipo conforme allo standard dellrsquoingresso
IngressiUscita RDnet ndeg2 x XLR RJ45 (cavo CAT 5)USB Tipo B
PARAMETRI CONTROLLO AUDIOGuadagno -80dB a +20dB passo 01dBRitardo
ingresso 0 a 729mS passo 01 mSuscita 0 a 340mS passo 01mS
Rotazione di fase 0deg - 180deg
COMPRESSIONESoglia -80dB a +20dB passo 01dBRapporto 11 a Inf1 passo 001Guadagno in uscita 0dB a 40dB passo 01dBTempo di attacco 1mS a 1000mS passo 01mSTempo di rilascio 1mS a 1000mS passo 01mSTempo di mantenimento 1mS a 1000mS passo 01mS
EQUALIZZATORI12 equalizzatori per ogni ingresso e uscitaTipo PEQ (parametrico) Hi-shelf Lo-sheft
Frequenza 20Hz a 20KHz passo 1HzGuadagno -30dB a +15dB passo 001dBBanda 005dB a 2dB passo 001dB (solo per PEQ)
FILTRI CROSSOVERFiltro Linkwitz Riley
Tipo HP Passa-AltoLP Passa-Basso
Pendenza 12dBoct - 24dBoct - 48dBoctFrequenza di taglio 5Hz a 20KHz passo 1Hz
ALIMENTAZIONE Full-range 100-240Vac 50-60HzDIMENSIONI 430482x43x130mm (LxHxD)PESO 19Kg
Note Specifiche soggette a variazioni senza preavviso
CLASSIFICAZIONE EMIIn accordo alle normative EN 55103 lapparato egrave progettato e idoneo allutilizzo in ambienti Elettromagnetici E3 o inferiori (E2 E1)
INTRODUCTIONAC26N is a digital sound processor for the management of audio systems designed for fixed and touring installations AC26N uses the most modern technology with 2856 bit processors and high performance 24 bits ADDA converters The functions available in the processor are input and output levels delay polarity 12 equalization bands for each input and output channel multiple crossover and high performance limiter The control resolution of the filters is 1Hz Inputs and outputs can be set according to many configurations to meet any need AC26N can be controlled in real time and each one of its parameters can be configured on the front panel and through a computer by means of an intuitive graphical interface accessible through the software DVA Network and a dedicated RDnet or USB network connectionThe CPU and DSP software update via PC allows to keep the device up to date It is possible to save and recall 32 preset configurations
Package Contents- AC26N - Operating manual- Software CD- Power cord
Characteristics- 2 Inputs and 6 Outputs with flexible routing- AESEBU addressable stereo inputs and outputs - 2856 bit DSP- BURR-BROWN high performance 24 bit AD converters- Frequency resolution of the filters 1 Hz - 12 parametric equalizers for each input and output- 2 crossover filters for each output with selectable slope 122448 dBoct- High performance DRC multi configuration for limitercompression configuration of
each input and output- Adjustable level in dB polarity and delay for each input and output- Firmware Update via PC- Graphic LCD Display- 32 pre-sets can be stored by the user- USB interface for configuration and control via computer- RDnet interface that allows to control up to 256 remote devices
PC
PC
RDNET hub(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FUNCTIONS FRONT PANEL
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
CONTROLS AND FUNCTIONS
1) DISPLAYThe graphic LCD display allows to view and edit the AC26N information without a computer The display contrast can be set within the main menu
2) ldquoFunctions Selectorrdquo and ldquoPush Enterrdquo KNOBThis control allows to move select and change the parameters within the displayed menusRotation of the knob (Function Selector)- it allows to browse the menu pages- it allows to change the selected parametersPush the knob (Push Enter)- it allows to selectconfirm the parameters
3) ESC button This control allows to exit the displayed menus or to return to the previous view
4) MENU button This control allows to directly access the main menu
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
En
glis
hE
nglis
hu
ser
man
ual
user
man
ual
16
user
man
ual
user
man
ual
Englis
hE
nglis
h
15
DVA USB Manager
The firmware of the amplifier module can be updated via the USB portTo make this update possible and simple a dedicated program has been developed
It is recommended to download DVA USB Manager free software directly from dB Technologies (wwwdbtechnologiescom) in the special section laquoSoftware amp Controllerraquo
DVA Network
The AC26N is equipped with proprietary network interface called RDNET for PC interface through a device (RDNET control)For this purpose a proprietary communication protocol has been developed for receiving and sending data this connection permits real-time monitoring of the diffuser parameters such as output power amplifier temperature limiter status etc It is also possible to select various equalizations or create new ones set the desired volume levels using the specific plug-in
It is recommended to download DVA Network free software directly from dB Technologies (wwwdbtechnologiescom) in the special section laquoSoftware amp Controllerraquo DOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
REAR PANEL CONNECTIONS
1586 75 141210 11 13 169 17
14) USB connectorThis USB connector (type B) allows to connect the processor to a compute to check and update the firmware via a dedicated program (DVA Network)
15) ldquoMAINSrdquo POWER CONNECTIONIt allows to connect the provided power cord
16) FUSE HOLDER ldquoFUSErdquoMain power supply fuse housing
17) ldquoPOWERrdquo MAIN SWITCHThis switch allows to switch on and off the device
PUSH
P SHU
SHPU
P SHU
PUSH
CONNECTIONS
Analog Audio ConnectionsBalanced connections allow to minimize the cable induced noise so cable can be longerSuch connections may be used both on inputs and outputsXLR connector must be cabled with pin 1 to ground pin 2 to hot (+) and pin 3 to cold (-) With shielded cables connect the shield to pin 1XLR-XLR e XLR-Jack 14(63 mm) connection cables can be used to connect the AC26N
12
3
Input
XLR - female
Pin 3 =NegativeCold-VE Phase
Pin 3 =NegativeCold-VE Phase
1 2
3
Output
XLR - Male
Pin 2 = PositiveHot+VE Phase
Pin 2 = PositiveHot+VE Phase
Pin 2 = PositiveHot+VE Phase
Pin 2 = PositiveHot+VE Phase
Pin 1 =ScreenGroundEarth
Pin 1 =ScreenGroundEarth
Pin 1 =ScreenGroundEarth
Pin 1 =ScreenGroundEarth
Ring
Sleeve
Tip = PositiveHot+VE Phase
Ring = NegativeCold-VE Phase
Sleeve=ScreenGroundEarth
Sleeve=ScreenGroundEarth
Tip
The unbalanced connections can also be used However the cable induced noise increases and cable length must not exceed 5 metersSuch connections may be used both on inputs and outputsUnbalanced connection may lower the level of the input signal up to 6dB in order to overcome this drawback connect pin 3 to ground although this can increase the noise
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
18
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
17
CONTROLS AND FUNCTIONS
5) -6dB SELECTORThis selector allows to reduce all the analog XLR [6] input levels by 6 dB at the same time to compensate for the high output levels on the mixers or other audio devices When the input signal level bar on the display [1] remains always at full scale this means that the input signal level is excessive and a -6 dB attenuation is recommendedIn the Option menu it is possible to check when the selector is activated
6) INPUT CONNECTORS ldquoArdquo AND ldquoBrdquoInputs balanced at line levelCapable to accept XLR male connectors
7) OUTPUT CONNECTORS ldquo1rdquo ldquo2rdquordquo 3rdquo ldquo4rdquo ldquo5rdquo AND ldquo6rdquoOutputs balanced at line level Capable to accept XLR famale connectors
Be careful to correctly connect each output to each speaker or amplifier according to the settings of each channels to avoid damages and malfunctions
ldquoAESEBUrdquo Section
8) INPUT CONNECTORIn addition to the analog audio inputs a SPDIF-AESEBU (AES3) digital audio input is also provided It can be selected via the setup menuSuch input requires a balanced connection trough an XLR connector with a 110 ohm twisted 3-wires cable
9) ldquoOUTrdquo OUTPUT CONNECTORThis connector allows to forward audio signals available at the digital or analog inputs or outputs The source must be set by means of the Option menuThe connection must comply with the same standard of the input [8]
RDNET Section
10) DATA INPUT CONNECTORData input RJ45 connector
11) ldquoDATA LINKrdquo OUTPUT CONNECTORRJ45 connector for data output used for serial link in cascade
12) ldquoONrdquo INDICATOR LIGHTThis green indicator turns on only when the AC26N has recognized the RDNET main unit and it is connected to it via computer
13) ldquoACTIVErdquo INDICATOR LIGHTThis yellow indicator flashes when data transmission between RDNET and the device is active
12
3
Input
XLR - female
1 2
3
Output
XLR - Male
Tip Gambo
Tip= Signal
Pin 3 = Link to Pin 1
Pin 3 = Link to Pin 1
Digital Audio Connections (AESEBU)AESEBU (AES3 protocol) is and a balanced input electrically insulated by means of a transformer It allows carrying two audio channels in a single two-wires shielded cable The cable characteristics are twisted 3 poles impedance 100 ohm shielded equipped with XLR connector (AES3 standard)
RDnetEach RDNet port on Control 2 and Control 8 can be connected to maximum 32 cascade-connected compatible devices In the example below the control unit RDNET CONTROL 2 port is connected to the DATA INPUT of an AC 26N whose parallel DATA LINK output is sent to the input of the next AC26N In the example [n] is a number between 3 and 32 (maximum limit for the devices connected to a sub-network)
RJ 45
|1|2|3|4|5|6|7|8|
The overall length of a CAT5 sub-network cable cannot exceed 900 meters
The connector must be connected as follows
1 - Available for other functions (for example audio +) 2 - Available for other functions (for example audio -)3 - Available for other functions (for example analog ground)4 - digital ground5 - digital ground6 - Available for other functions (for example power supply)7 - RS 485 A8 - RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
POWER ON
When the device is turned on the initialization procedure starts It lasts few seconds The display shows the device model the company logo and a program loading progress bar
At the end of the installation process the display shows the Meters menu For further details about the indications refer to the paragraph MENU DESCRIPTION - METERS
AC26N is now ready for use
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION AND DISPLAY
To access the main menu window press the MENU key located on the device front panelIn any page of the menu press the ESC button to return to the previous screen
MAIN MENU
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
There are six menus in the processor They show andor configure the system parametersThe main menus are
Meters Input and output levels display program in progress display quick muting
Preset Store save and delete the system configurations
Matrix Select the outputs according to the input signal
Ch Job Configuration of each individual channel
X-Over Configuration of the cut-off frequency and the types of filters for each output
Option Assignment of the inputs and outputs display contrast firmware version inputs and other options
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
20
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
19
The menus and the individual options displayed can be selected by rotating the knob ldquoFUNCTION SELECTORrdquo ( ) To access the selection highlight the desired parameter and press the ldquoPush Enterrdquo ( | ) knobThe same procedure should be adoptd to select andor change the options inside each menu entry
MENU DESCRIPTION - ldquoMetersrdquo
This window allows to view the configuration and the general conditions of the inputs and outputs the version of the program used the program status and how the system is driven
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) INPUT AND OUTPUT CHANNELSThe input and output connectors are identified by the same information provided on the screen printing located on the device rear sideWith digital input signals the indications A and B concern the inputBy rotating the knob FUNCTION SELECTOR [2] input channels output channels and general muting indications are cyclically scrolled (d) the selected channel is highlighted
b) BAR COMPRESSION LEVEL CHANNEL MUTING
SIGNAL COMPRESSIONSignal compression is displayed by the vertical scrolling (top to down) of the right bar
MUTE Each channel can be individually muted Select the channel and press the Push Enter knob [2] to confirm the change of status The indication of the channel will be replaced by the letter M and the bar will be completely highlightedTo restore normal operation repeat the actions described above
c) SIGNAL LEVEL BARThe level indication for each channel is provided by scrolling the left bar
d) GENERAL MUTINGIt is possible to mute all the inputs and outputs simultaneously Rotate the knob FUNCTION SELECTOR select the letter M and press the Push Enter knobTo restore normal operation repeat the actions described aboveThe general mute has the highest priority with respect to the muting of individual channels
e) CONTROL MODEIt shows how the AC26N is used andor to which devices it is connected
Local = stand-alone usage No connection to an external device
NET = directly connected to dedicated RDnet network and to computer
USB = directly connected to another computer via USB cable
f) SETTING STATUS INDICATIONThis indication shows if the loaded program was amended in one or more parameters with respect to the last saving operation
= original program
= program with modified parameters
g) SET PROGRAMThe number shows the program that is loaded and used by the system with reference to the saving position Refer to the ldquoPresetrdquo menu for further details
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
MENU DESCRIPTION - CH JOB
This window allows to view the configuration of each individual channel
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) INPUT AND OUTPUT CHANNELSThe input and output connectors are identified by the same information provided on the screen printing located on the device rear side
b) SIGNAL LEVELIt shows the signal gain The increased signal intensity is expressed in decibels (dB) Such parameter can be selected in the range from -8000 dB to +2000 dB in steps of 001 dB An increase of 6 dB is approximately equal to doubling - in a linear scale - the signal voltage levelIf the gain exceeds 0 dB the signal is amplified while if the gain is lower than 0 dB the signal is attenuated
c) SIGNAL DELAYThe reproduced audio signal may be delayed to perform an acoustic alignment This compensates for the different positions of the speakers during the installation and the sound reproduction it is expressed in ms The parameter can be selected in the range from 00 ms to 729 ms in steps of 01 msThe following formula can be used to align an audio signal
Delay = (GAPx1000)344
Delay = ms (in milliseconds)GAP = distance between speaker and reference point (in meters)Speed of sound = 344 ms
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
22
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
21
d) MUTEEach channel can be individually muted The same command can be activated in the Meters Menu
NOTE The general mute has the highest priority with respect to the muting of individual channels
e) PhaseIt performs a phase rotation of 180deg with respect to the input signalSuch phase rotation allows the optimization in special way for low frequencies in complex installations
M M
f) EQUALIZATIONThis control opens the menu controlling the single channel equalization It is mainly used to correct one or more frequencies that must be reduced or increased
The AC26N manages 12 filters for each individual channel input and output with three different kinds of configuration
- PEQ Equaliser (peaking equalizer) ideal to identify isolate and correct only a certain range of frequencies All frequencies pass only those around the centre frequency are increased and decreased for a given bandwidth and set gain
- High-shelf Equalizer All frequencies pass but frequencies above the selected cut-off frequency are increased or attenuated by the given gain
- Low-shelf Equalizer All frequencies pass but frequencies below the selected cut-off frequency are increased or attenuated by the given gain
f Numbering of the 12 available filters for the specific input or output1
f Displays the kind of filter2
Dis Switched off (not present)
PEQ Peaking equlizer
Sh H High-shelf Filter
Sh L Low-shelf Filter
Examples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
NOTE
The parameter Bw defines the range of frequencies close to the set frequency where the filter is activated the greater the value of Bw the wider is the frequencies range (1 Bw = 1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONThis control opens the menu controlling the compression for the single channel
g1) ThresholdIdentifies the starting threshold for the compression ratio Base value 11
g2) RatioIndicates the conversion ratio between input and output signal
g3) Post Gain Attach Release HoldThese data are in function of the conversion ratio to achieve Post Gain is the output gain Attack is the attack time Release is the release time Hold is the holding time
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
24
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
23
MENU DESCRIPTION - PRESET
This window allows to store up to 32 configurations in the AC26NThe manufacturer provides the system with a program set and saved in position 0 that is not possible to overwrite
032 Indicates the location where the configuration is savedThis number also appears in the window Meters in position (g) The program in use can be displayed at any time by the user
Empty Preset It is the name associated with the location number when no setting is saved (empty)
Local preset It is the name associated with the location number when a setting is saved NOTE = It is possible to save a setting with the desired name up to 16 letters only via the computer interface
When a program is selected the following window is displayed
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
The name of the assigned program is displayed3 possible choices are available when working on the application
Save The program is saved in the AC 26N memory
Del The program is deleted
Load The program is loaded and ready to be used
MENU DESCRIPTION - X-OVER
This window allows to select for each output a low pass filter a high pass filter or create a band-pass filter via the combination of bothThe available filter is a Linkwitz-Riley where it is possible to select slopes of 12 dBoct 24 dBoct or 48 dBoct and their cut-off frequency
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) OUTPUT CHANNELS
The output connectors are identified by the same information provided on the screen printing located on the device rear side
b) CROSSOVER FILTERSelect the filter according to needs It is possible to select
Dis No filter enabled
HP High-pass filter set it to allow only the part of audio signal above the cut-off frequency
LP Low-pass filter set to allow only the part of audio signal below the cut-off frequency
Filter configuration Low-pass High-pass
Nothing Dis Dis
High-pass HP Dis
Low-pass Dis LP
Band-pass HP LP
12dBoct
24dBoct
Hz
dB
48dBoct
12dBoct
24dBoct
frequency
frequency
frequency
frequency
Hz
dB
48dBoct
c) ATTENUATION SLOPESelect the attenuation slope of the audio signal on the basis of the desired attenuation The higher the attenuation slope at the same cut-off frequency the greater the signal selection It is possible to select
12 equal to 12 dBoct
24 equal to 24 dBoct
48 equal to 48 dBoct
d) CUT-OFF FREQUENCYTo set the passing frequency for the lower frequencies only (low-pass filter) or the higher frequencies only (high-pass filter)The choice of the cut-off depends on the desired sound reproductionThe unit of measurement used is Hz
Hz
Hz
dB
dB
Ga
inG
ain
Ga
inG
ain
f0
f0
0dB0dB
0dB
-6dB
-6dB
0dB
0dB
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
26
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
25
MENU DESCRIPTION - MATRIX
For each output it allows to select the input signal to use as the source
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) OUTPUT CHANNELSIdentification of the output channel to set
b) IDENTIFICATIONS OF THE INPUTSIt selects the type of signal to match each output as needed It is possible to select
In A Associated with the input signal ldquoArdquo
In B Associated with the input signal ldquoBrdquo
In A+B Associated with the algebraic sum of the two input signals ldquoArdquo and ldquoBrdquo
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
MENU DESCRIPTION - OPTION
Allows to display the system settings such as the allocation of the inputs and outputs attenuation display contrast and firmware version
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcThis option allows to set the type of input audio signal
An In = Analog audio signals (inputs A and B)
DigIn = Digital audio signals (AESEBU input)
DigOut SrcThis option allows to select the audio source that will be forwarded to the connector AESEBU OUT (digital output)
An In = Audio signals available at analog inputs
Dig In = Audio signals available at digital inputs
OUT 1-2 = Audio signals available on outputs 1 and 2
OUT 3-4 = Audio signals available on outputs 3 and 4
OUT 5-6 = Audio signals available on outputs 5 and 6
Input ModeIt allows to configure the inputs
Indip = They are independent not subject to constraints of any kind between them
Linked = They are connected and work in stereo mode Compressors filters delays volume are identical for the two channels
Atten PadIt shows how to set the -6 dB switch located on the rear side [Ref 5] It is necessary to activate this selector when the analog input levels are too high The selector can be activated only by means of the button the menu is for display only
0 dB = Selector not activated The input signals are the same as the input source
-6 dB = Selector activated The input signals are attenuated by -6 dB with reference to the inner
processor
ContrastAllows to adjust the LCD display contrast to compensate for the brightness difference at the installation sites Greater display brightness allows to navigate correctly and quickly within the menuThe manufacturer output setting is 60
10 More bright 60 More dark 100
Fw VersIt shows the processor firmware version
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
28
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
27
TECHINICAL SPECIFICATION
AUDIO PERFORMANCEFrequency Response +- 01dB (20 to 30kHz)Dynamic Range 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistortion 0002 (1kHz +4dBu)
DIGITAL AUDIO PERFORMANCE Processor DSP 2856-bit Data processing Frequency 24-bit BURR BROWNAnalog converters 24-bit BURR BROWNPropagation Delay 15msStoring configurations 32 preset
CONTROLS Display LCD graficoButtonsControls ESC - MENU - FUNCTIONS SELECTION
ENTERINPUTSOUTPUTSAnalog Input ndeg2 x XLR (3 pole female)
Input impedance gt10KOhmMaximum Level +21dBu senza PAD
+27dBu con PADAnalog Output ndeg6 x XLR (3 pole male)
Output impedance 50OhmMaximum Level +21dBu Type Balanced
Digital Input ndeg1x XLR (3 pole female)Type SPDIF-AESEBU (AES3)
Digital Output ndeg1x XLR (3 pole male)Type Compliant with the input standard
RDnet InputsOutput ndeg2 x XLR RJ45 (CAT 5 cable)USB Tipo B
SOUND CONTROL PARAMETERSGain -80dB a +20dB step 01dBDelay
Input 0 a 729mS step 01 mSOutput 0 a 340mS step 01mSPhase Rotation 0deg - 180deg
COMPRESSIONThreshold -80dB a +20dB step 01dBRatio 11 a Inf1 step 001Output gain 0dB a 40dB step 01dBAttack time 1mS a 1000mS step 01mSRelease time 1mS a 1000mS step 01mSHold time 1mS a 1000mS step 01mS
EQUALIZERS12 equalizers for each input and outputType PEQ (parametrico) Hi-shelf Lo-sheft
Frequency 20Hz a 20KHz step 1HzGain -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (only with PEQ)
CROSSOVER FILTERSFilter Linkwitz Riley
Type HP High-pass LP Low-pass
Slope 12dBoct - 24dBoct - 48dBoctCUT-OFF FREQUENCY 5Hz a 20KHz passo 1Hz
POWER SUPPLY Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)
1719x17x51 inch (WxHxD)WEIGHT 19Kg
(42 lbs)Note Specifications subject to change without notice
EMI CLASSIFICATIONAccording to the standards EN 55103 this equipment is designed and suitable to operate in E3 (or lower E2 E1) Electromagnetic environments
EINLEITUNG
Verpackungsinhalt
Eigenschaften
AC26N ist ein digitaler Audio-Prozessor fuumlr die Verwaltung von Audio-Systemen der fuumlr feste und mobile Installationen entwickelt wurde AC26N benutzt die modernste Technologie mit 2856 bit-Prozessoren und 24-bit-ADDA-Wandlern mit hoher Leistungsfaumlhigkeit Die verfuumlgbaren Funktionen des Prozessors sind Ein- und Ausgangsstufen Verzoumlgerung (delay) Polaritaumlt 12 Equalizer-Frequenzen fuumlr Ein- und Ausgangskanal viele Crossover-Wahlmoumlglichkeiten und Limiter mit hoher Leistung Die Filter-Kontrolle hat eine Aufloumlsung von 1 Hz Die Ein- und Ausgaumlnge koumlnnen mit unterschiedlichen Einstellungen geregelt werden um allen Anforderungen gerecht zu werden AC26N kann in Echtzeit kontrolliert werden und jeder Parameter kann am Frontpaneel und vom Computer mit intuitiver graphischer Schnittstelle mittels Software DVA Network zugaumlnglich und einer Netzverbindung RDnet oder uumlber USB eingestellt werdenDie SW-Aktualisierung fuumlr CPU und DSP uumlber PC erlaubt die Vorrichtung auf dem aktuellen Stand zu halten Man kann 32 vorgesehene Konfigurationen speichern und aufrufen
- AC26N - Bedienungsanleitung- Software-CD- Versorgungskabel
- 2 Ein- und 6 Ausgaumlnge mit flexibler Adressierung- Adressierbarer Stereo-Ein- und Ausgang AESEBU - DSP 2856-bit- AD-Wandler BURR BROWN 24-bit mit hoher Leistungsfaumlhigkeit- Aufloumlsungsfrequenz der Filter 1 Hz - 12 parametrische Equalizer fuumlr jeden Ein- und Ausgang- 2 Crossover-Filter fuumlr jeden Ausgang mit auswaumlhlbarer Neigung 122448dBoct- DRC Multikonfiguration mit hoher Leistungsfaumlhigkeit fuumlr die Konfiguration des
Limitersder Kompression jedes Ein- und Ausgangs- Einstellbare dB-Stufe Polaritaumlt und Verzoumlgerung (delay) fuumlr jeden Ein- und Ausgang- Firmware-Aktualisierung uumlber PC- Graphisches LCD-Display- 32 Voreinstellungen vom Benutzer einstellbar- USB-Schnittstelle fuumlr die Kontrolle und Konfiguration mit dem Computer- Schnittstelle RDnet welche erlaubt bis zu 256 fern liegende Vorrichtungen
zu kontrollieren
PC
PC
RDNET control(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FUNKTIONEN VORDERSEITE
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
BEDIENUNGEN UND FUNKTIONEN
1) DISPLAYDas graphische LCD-Display erlaubt die Informationen des AC26N ohne einen Computer zu benutzen anzuzeigen und zu editieren Der Kontrast kann im Hauptmenuuml eingestellt werden
2) DREHGRIFF Functions Selector UND Push EnterDiese Kontrolle erlaubt sich in den Menuumls auf dem Display zu bewegen und die Parameter auszuwaumlhlen und zu veraumlndernDrehung des Drehgriffes (Functions Selectors)- Man kann sich innerhalb der verschiedenen Menuumlseiten bewegen- Erlaubt die Veraumlnderung der ausgewaumlhlten ParameterDruck des Drehgriffes (Push Enter)- Erlaubt die AuswahlBestaumltigung der Parameter
3) Taste ldquoESCrdquo Diese Kontrolle erlaubt die angezeigten Menuumls zu verlassen oder zur vorherigen Anzeige zuruumlckzukehren
4) Taste ldquoMenuumlrdquo Diese Kontrolle erlaubt den direkten Zugang zum Hauptmenuuml
Deuts
chD
euts
chB
ed
ien
un
gsan
leit
un
gB
ed
ien
un
gsan
leit
un
g
29
Deuts
chD
euts
chB
ed
ien
un
gsan
leit
un
gB
ed
ien
un
gsan
leit
un
g
30
DVA USB Manager
Die Firmware des Verstaumlrkermoduls kann uumlber den USB-Anschluss aktualisiert werdenUm diesen Vorgang zu ermoumlglichen und zu vereinfachen wurde ein dediziertes Programm entwickelt das beim Hersteller angefordert und auf einen Computer installiert werden muss
Wir empfehlen die Software DVA USB Manager direkt von der Webseite dB Technologies (wwwdbtechnologiescom) im Abschnitt laquoSoftware amp Controllerraquo herunterzuladen
DVA Network
AC26N ist mit einer eigenen als RDNET bezeichneten Netzschnittstelle ausgestattet dank der es uumlber ein Interface (RDNET Control) an einen Computer angeschlossen werden koumlnnenHierzu wurde ein Kommunikationsprotokoll entwickelt mit dem die Daten empfangen und gesendet werden Dank dieser Verbindung koumlnnen die Lautsprecherparameter wie Ausgangsleistung Verstaumlrkertemperatur Limiterstatus usw in Echtzeit kontrolliert werden Auszligerdem koumlnnen verschiedene Entzerrungen ausgewaumlhlt bzw neue erstellt werden oder die gewuumlnschte Lautstaumlrke eingestellt werden
Wir empfehlen die Software DVA_Network direkt von der Webseite dB Technologies (wwwdbtechnologiescom) im Abschnitt laquoSoftware amp Controllerraquo herunterzuladenDOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
RUumlCKWANDANSCHLUumlSSE
1586 75 141210 11 13 169 17
14) USB-SteckverbinderDieser USB-Steckverbinder (Typ B) erlaubt den Prozessor an einem Computer anzuschlieszligen um die Firmware mit dem speziellen Programm (DVA Network) zu kontrollieren und zu aktualisieren
15) STROMANSCHLUSS MAINSErlaubt den Anschluss des mitgelieferten Versorgungskabels
16) SICHERUNGSTRAumlGER FUSEAufnahme fuumlr die Netz-Sicherung
17) HAUPTSCHALTER POWERDer Schalter erlaubt das Aus- und Einschalten des Audio-Controllers
BEDIENUNGEN UND FUNKTIONEN
5) WAHLSCHALTER -6dBDer Wahlschalter erlaubt das Level des analogen Eingangs XLR [6] um 6 dB zu verringern und gleichzeitig das hohe Ausgangslevel der Mixer oder anderer Audio-Vorrichtungen auszugleichen Wenn der Balken des Signallevels der Eingaumlnge auf dem Display [1] immer auf Maximum steht zeigt dies an dass das Signallevel am Eingang hoch ist und es wird empfohlen die Daumlmpfung -6dB zu benutzenIm Menuuml Option ist es moumlglich zu kontrollieren ob der Wahlschalter aktiviert ist
6) STECKVERBINDER AM EINGANG A UND BAuf Leitungslinie ausgeglichene EingaumlngeSie koumlnnen auch XLR-Steckdosen aufnehmen
7) AUSGANG-STECKVERBINDER ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo UND ldquo6rdquoAuf Leitungslinie ausgeglichene Ausgaumlnge Sie koumlnnen auch XLR-Stecker aufnehmen
Darauf achten dass die Ausgaumlnge korrekt entsprechend der Einstellungen der einzelnen Kanaumlle an den Lautsprechern oder Verstaumlrkern angeschlossen sind um Schaumlden und Fehlfunktionen vorzubeugen
Abschnitt ldquoAESEBUrdquo
8) EINGANGS-STECKVERBINDER INZusaumltzlich zu den analogen Audio-Eingaumlngen wurde ein digitaler Audio-Eingang SPDIF-AESEBU (AES3) vorgesehen der uumlber das Setup-Menuuml ausgewaumlhlt werden kannDer Eingang erfordert einen ausgeglichenen Anschluss mit einem XLR-Steckverbinder mit einem verdrillten Kabel mit 3 Leitern von 110 Ohm
9) AUSGANGS-STECKVERBINDER OUTDieser Steckverbinder erlaubt das Audiosignal an den analogen oder digitalen Eingaumlngen oder Ausgaumlngen zu verteilen Die Quelle muss uumlber das Menuuml Option eingestellt werdenDer Anschluss muss demselben Standard des Eingang entsprechen [Ref 8]
Abschnitt ldquoRDNETrdquo
10) EINGANGS-STECKVERBINDER DATA INPUTSteckverbinder RJ45 fuumlr den Dateneingang
11) AUSGANGS-STECKVERBINDER DATA LINKSteckverbinder RJ45 fuumlr den Datenausgang Fuumlr die serielle Kaskaden-Verbindung
12) LEUCHTANZEIGE ONDiese gruumlne Anzeige leuchtet nur wenn AC26N uumlber den Computer mit der Haupteinheit RDNET verbunden ist und diese erkannt hat
13) LEUCHTANZEIGE ACTIVEDiese gelbe Anzeige blinkt wenn eine Datenuumlbertragung zwischen RDNET und der Vorrichtung aktiv ist
PUSH
P SHU
SHPU
P SHU
PUSH
ANSCHLUumlSSE
Analoge Audio-AnschluumlsseDie ausgeglichenen Anschluumlsse erlauben die Geraumlusche der Kabel auf ein Minimum zu verringern und so die Benutzung langer Kabel zuzulassenDiese Anschluumlsse koumlnnen sowohl an den Ein- als auch an den Ausgaumlngen benutzt werdenDer XLR-Steckverbinder muss mit Pin 1 an Masse Pin 2 am Pluspol (+) und Pin 3 am Minuspol (-) angeschlossen werden Bei einem abgeschirmten Kabel muss die Abschirmung an Pin 1 liegenDie Verbindungskabel XLR-XLR und XLR-Jack 14 (63 mm) koumlnnen fuumlr den Anschluss
12
3
Eingang
XLR weiblichen
Pin 3 = MinuspolErkaumlltungphase -VE
Pin 3 = MinuspolErkaumlltungphase -VE
1 2
3
Ausgang
XLR maumlnnlichen
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Ring
Schaft
Spitze = PluspolWaumlrmephase +VE
Ring = MinuspolErkaumlltungphase -VE
Schaft=SchirmMasse
Spitze
Die nicht ausgeglichenen Anschluumlsse koumlnnen auch benutzt werden wenn die Kabelgeraumlusche ansteigen und diese Kabel duumlrfen nicht laumlnger sein als 5 MeterDiese Anschluumlsse koumlnnen sowohl an den Ein- als auch an den Ausgaumlngen benutzt werdenDie nicht ausgeglichenen Anschluumlsse koumlnnen das Signallevel am Eingang um 6 dB verringern um dem vorzubeugen muss Pin 3 an Masse angeschlossen werden obwohl dies das Geraumlusch verstaumlrken kann
12
3
Eingang
XLR weiblichen
1 2
3
Ausgang
XLR maumlnnlichen
Spitze Schaft
Spitze = Signal
Schaft=SchirmMasse
Pin 3 = zu Pin 1 gebruumlckt
Pin 3 = zu Pin 1 gebruumlckt
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
31
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
32
Digitales Audio (AESEBU)AESEBU (Protokoll AES3) ist ein ausgeglichener und uumlber einen Transformator elektrisch isolierter Eingang Er erlaubt die Benutzung von zwei Kanaumllen an einem einzigen abgeschirmten bipolaren Kabel Das gedrillte Kabel muss 3-polig sein eine Impedanz von 100 Ohm haben und mit einem XLR-Steckverbinder (AES3 Standard) abgeschirmt sein
RdnetJeder Port RDNet an Control 2 und Control 8 kann an max 32 kompatiblen Vorrichtungen die in Kaskade geschaltet sind angeschlossen werden Im nachstehenden Beispiel ist der Port der Kontrolleinheit RDNET CONTROL 2 am Eingang DATA INPUT eines AC 26N angeschlossen dessen paralleler Ausgang DATA LINK zum Eingang des naumlchsten AC26N geht Im Beispiel ist [n] eine Nummer zwischen 3 und 32 (maximale Anzahl der anschlieszligbaren Vorrichtungen an nur einem Netz)
RJ 45
|1|2|3|4|5|6|7|8|
Die Gesamtlaumlnge des Kabels CAT5 eines Unternetzes kann NICHT laumlnger als 900 Meter sein
Der Steckverbinder muss wie folgt angeschlossen sein1 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio +) 2 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio -)3 ndash Verfuumlgbar fuumlr andere Funktionen (zB analoge Masse)4 ndash digitale Masse5 ndash digitale Masse6 ndash Verfuumlgbar fuumlr andere Funktionen (zB Versorgung)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
EINSCHALTEN
Beim Einschalten der Vorrichtung startet die Initialisierung die einige Sekunden lang dauert Auf dem Display wird das Modell das Logo und der Fortschrittsbalken der Ladung des Programms angezeigt
Nach der Initialisierung erscheint auf dem Display das Menuumlfenster Meters Um die Angaben im Detail zu erfahren beziehen Sie sich bitte auf das Kapitel BESCHREIBUNG DES MENUumlFENSTERS Meters
AC26N kann jetzt benutzt werden
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
MENUrsquo PRINCIPALE
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Die sechs Menuumls im Prozessor zeigen undoder konfigurieren die Systemparameter
Anzeige der Levels der Ein- und Ausgaumlnge Anzeige des benutzten Programms und dessen Status Mute schnell
Speicherung Speicherung und Eliminierung der Systemkonfigurationen
Auswahl der Ausgaumlnge je nach Eingangssignal
Konfiguration jedes einzelnen Kanals
Konfiguration der Schnittfrequenzen und der Filtertypen fuumlr jeden einzelnen Ausgang
Zuordnung der Ein- und Ausgaumlnge Kontrast des Displays Firmware-Version Eingaumlnge und andere Optionen
Das Menuuml und die einzelnen Optionen der Anzeige koumlnnen durch Drehen des Drehgriffes FUNKTIONS SELECTOR ( ) ausgewaumlhlt werden
Die Hauptmenuumls sind
Meters
Preset
Matrix
Ch Job
X-Over
Option
Um die Auswahl zu treffen muss der gewuumlnschte Parameter auswaumlhlt und der Drehgriff Push Enter( | ) gedruumlckt werdenDas selbe Verfahren muss fuumlr die Auswahl undoder die Aumlnderung der Optionen innerhalb der Menuumlpunkte angewendet werden
BESCHREIBUNG DES MENUumlFENSTERS Meters
Diese Seite erlaubt die Konfigurationen und den allgemeinen Status der Ein- und Ausgaumlnge der benutzten Programmversion dessen Status und die Steuerung des Systems anzuzeigen
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
KONFIGURATION UND ANZEIGE
Um in das Fenster des Hauptmenuumls zu gelangen muss die Taste Menuuml ( ) auf der Frontseite der Vorrichtung gedruumlckt werdenMit der Taste ESC ( ) kehrt man von jeder Seite des Menuumls auf die vorherige Seite zuruumlck
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
33
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
34
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziertBei den digitalen Eingangssignalen entspricht die Angabe A und B dem EingangDreht man den Drehgriff FUNCTIONS SELECTOR [2] durchlaumluft man zyklisch die Ein- und Ausgangskanaumlle und die Angabe Mute allgemein (d) der ausgewaumlhlte Kanal wird hervorgehoben
b) BALKEN FUumlR DAS KOMPRESIONSLEVELMUTE KANAL
SIGNALKOMPRESSIONDie Signalkompression wird durch das Gleiten des rechten Balkens von oben nach unten angezeigt
MUTE Jeder einzelne Kanal kann auf Mute gestellt werden Den Kanal auswaumlhlen und den Drehgriff Push Enter [2] druumlcken um die Aumlnderung des Status zu bestaumltigen Die Angabe des Kanals wird durch den Buchstaben M ersetzt und der Balken wird komplett hervorgehobenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werden
c) BALKEN DES SIGNALLEVELSDie Anzeige des Levels jedes einzelnen Kanals wird durch das Gleiten des linken Balkens angezeigt
d) MUTE ALLGEMEINEs ist moumlglich alle Ein- und Ausgaumlnge gleichzeitig auf Mute zu schalten Den Drehgriff FUNCTIONS SELECTOR drehen den Buchstaben M waumlhlen und dann den Drehgriff Push Enter druumlckenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werdenDie allgemeine Stummschaltung hat eine houmlhere Prioritaumlt als die Stummschaltung der einzelnen Kanaumlle
e) ANSTEUERUNGSARTENEs wird angezeigt wie AC26N benutzt wird undoder an welchen Vorrichtungen es angeschlossen ist
= Benutzung stand-alone Kein Anschluss an einer externen Vorrichtung
= Direkt am Netz RDnet und am Computer angeschlossen
= Uumlber USB-Kabel direkt am Computer angeschlossen
f) ANZEIGE DES STATUS DER EINSTELLUNGENHier wird angezeigt ob einer oder mehrere Parameter des geladenen Programms im Vergleich zur letzten Speicherung veraumlndert wurden
Original-Programm
Programm mit veraumlnderten Parametern
g) EINGESTELLTES PROGRAMMDie Nummer zeigt das vom System geladene und benutzte Programm in Bezug auf die Lokalisierung der Speicherung an Fuumlr weitere Details beziehen Sie sich bitte auf das Menuuml Preset
Local
NET
USB
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
BESCHREIBUNG DES MENUumlFENSTERS Ch Job
Dieses Fenster erlaubt die Anzeige der Konfiguration jedes einzelnen Kanals
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) SIGNALLEVELZeigt die Signalstaumlrke an Das Ansteigen der Signalintensitaumlt wird in Dezibel (dB) ausgedruumlckt Der Parameter kann zwischen -8000 dB und +2000 dB in Schritten von 001 dB ausgewaumlhlt werden Ein Anstieg von 6 dB ist fast gleich eine Verdoppelung in linearer Skala des Spannungswertes des SignalsBei einer Staumlrke von 0 dB wird das Signal verstaumlrkt waumlhrend es ein einer Staumlrke von weniger als 0 dB abgeschwaumlcht wird
c) VERZOumlGERUNG DES SIGNALS (DELAY)Das wiedergegebene Audio-Signal kann verzoumlgert werden um die akustische Ausrichtung zu erlauben Dies gleicht die verschiedenen Positionen der Lautsprecher bei der Installation und Klangwiedergabe aus und wird in mS ausgedruumlckt Der Parameter kann zwischen 00 mS und 729 mS in Schritten von 01mS ausgewaumlhlt werden
Um ein Audiosignal auszurichten kann folgende Formel benutzt werden
Verzoumlgerung = GAPx1000)344
Verzoumlgerung = mS (in Millisekunden ausgedruumlckt)GAP = Abstand des Lautsprechers vom Referenzpunkt (in Metern ausgedruumlckt)Klanggeschwindigkeit = 344 ms
d) MUTEJeder einzelne Kanal kann auf Mute gestellt werden Derselbe Befehl kann im Fenster des Menuumls Meters aktiviert werden PS Die al lgemeine Stummschaltung hat eine houmlhere Priori taumlt als die Stummschaltung der einzelnen Kanaumlle
e) PHASEErlaubt die Phasenrotation um 180deg zum EingangssignalDiese Rotation erlaubt vor Allem die Optimierung der niederen Frequenzen bei komplexen Installationen
f) ENTZERRUNGENDieser Befehl oumlffnet das Menuumlfenster fuumlr die Entzerrung des einzelnen Kanals Er wird vor Allem benutzt um eine oder mehrere Frequenzen zu korrigieren die gedaumlmpft oder verstaumlrkt werden muumlssen
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
35
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
36
AC26N verwaltet 12 Filter fuumlr jeden einzelnen Ein- und Ausgangskanal mit drei verschiedenen Konfigurationen- Equalizer PEQ (peaking equalizer) ist ideal um nur ein bestimmtes Frequenzband
zu identifizieren zu isolieren und zu korrigieren Es gehen alle Frequenzen durch aber nur die um die mittlere Frequenz steigt und sinkt um eine bestimmte Bandbreite und eine bestimmte Staumlrke
- Equalizer High-Shelf geht alle Frequenzen durch aber die Frequenzen uumlber der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
- Equalizer Low-Shelf geht alle Frequenzen durch aber die Frequenzen unter der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
f Nummerierung der 12 verfuumlgbaren Filter fuumlr diesen Ein- oder Ausgang1
f2 Es wird der Filtertyp angezeigt
Dis Ausgeschaltet (nicht vorhanden)
PEQ Peaking equalizer
Sh H Filter High-Shelf
Sh L Filter Low-shelf
Beispiele PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
ANMERKUNGDer Parameter Bw legt das Frequenzfeld neben der eingestellten Frequenz fest wo der Filter aktiviert wird je houmlher der Bw-Wert desto houmlher das Frequenzfeld (1Bw=1 Oktave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filter High-Shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filter Low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) KOMPRESSIONDieser Befehl oumlffnet das Menuumlfenster fuumlr die Kompression des einzelnen Kanals
g1) TresholdIdentifiziert die Schwelle an der das Kompressionsverhaumlltnis beginnt Der Basiswert 11
g2) RatioIdentifiziert das Kompressionsverhaumlltnis zwischen dem Ein- und Ausgangssignal
g3) Post Gain Attach Release HoldDiese Daten entsprechen dem Kompressionsverhaumlltnis das man erreichen moumlchte
Post Gain ist der Gewinn am AusgangAttack ist die Anschlusszeit Release ist die ReleasezeitHold ist die Beibehaltungszeit
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
BESCHREIBUNG DES MENUumlFENSTERS Preset
Dieses Fenster erlaubt bis zu 32 Konfigurationen im AC26N zu speichernDer Hersteller liefert das System mit einem voreingestellten Programm das auf Position 0 gespeichert ist und nicht uumlberschrieben werden kann
032 Es zeigt die Lokalisierung der Speicherung der KonfigurationDiese Nummer erscheint auch im Fenster Meters auf der Position (g) Das benutzte Programm kann jederzeit vom Benutzer angezeigt werden
Empty Preset Es ist der Name der der Nummer der Lokalisierung zugeordnet wird wenn keine Einstellung gespeichert ist (leer)
Local preset Es i s t de r Name de r de r Nummer de r Loka l i s i e rung zugeordnet wird wenn eine Konfiguration gespeichert wird
ANMERKUNG = Man kann eine Einstellung mit dem gewuumlnschten Namen mit max 16 Buchstaben nur speichern wenn man die Schnittstelle uumlber den Computer benutzt
Bei der Wahl eines Programms erscheint folgendes Fenster
Anzeige des Namens der dem Programm zugeordnet istUm auf die Anwendung einzuwirken stehen 3 Auswahlmoumlglichkeiten zur Verfuumlgung
Das Programm wird im Speicher des AC 26N gespeichert
Das Programm wird geloumlscht
Das Programm wird geladen und ist bereit fuumlr die Benutzung
Save
Del
Load
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
37
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
38
BESCHREIBUNG DES MENUumlFENSTERS X-Over
Dieses Fenster erlaubt fuumlr jeden Ausgang einen Bassdurchgangsfilter einen Hochdurchgangsfilter oder mittels Kombination von beiden einen Banduumlbergangsfilter zu waumlhlenDer Filter ist ein Linkwitz-Riley wo man die Neigung von 12 dBoct 24dBoct oder 48 dBoct und die entsprechende Schnittfrequenz auswaumlhlen kann
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) AUSGANGSKANAumlLE
Die Steckverbinder am Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) FILTER CROSSOVERDen Filter nach Bedarf waumlhlen Man kann folgendes auswaumlhlen
Dis Kein Filter aktiviert
HP Hochdurchgangsfilter nur den Teil des Audiosignals durchlassen der uumlber der Schnittfrequenz liegt
LP Bassdurchgangsfilter nur den Teil des Audiosignals durchlassen der unter der Schnittfrequenz liegt
Filter-Konfiguration Tiefpass Hochpass
Nichts Dis Dis
Hochpass HP Dis
Tiefpass Dis LP
Bandpass HP LP
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
c) DAumlMPFUNGSNEIGUNGDie Daumlmpfungsneigung des Audiosignals auf der Basis der Verringerung auswaumlhlen die man erreichen moumlchte Je houmlher die Daumlmpfungsneigung bei gleicher Schnittfrequenz desto groumlszliger ist die Signalauswahl Man kann folgendes waumlhlen
12 entsprechend 12 dboct
24 entsprechend 24 dboct
48 entsprechend 48 dboct
d) SCHNITTFREQUENZErlaubt die Durchgangsfrequenz der niederen Frequenzen (Bassdurchgangsfilter) oder der hohen Frequenzen (Hochdruchgangsfilter) einzustellenDie Auswahl des Schnitts bezieht sich auf die Wiedergabe die man erreichen moumlchteDie benutzte Maszligeinheit ist Hz
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
BESCHREIBUNG DES MENUumlFENSTERS Matrix
Erlaubt fuumlr jeden Ausgang das Eingangssignal zu waumlhlen das als Quelle benutzt werden soll
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) AUSGANGSKANAumlLEIdentifizierung des einzustellenden Ausgangskanals
b) IDENTIFIZIERUNG DER EINGAumlNGEDen Signaltyp auswaumlhlen der nach eigener Anforderung jedem einzelnen Ausgang zugeordnet werden soll Man kann folgendes waumlhlen
In A Das Signal wird dem Eingang A zugeordnet
In B Das Signal wird dem Eingang B zugeordnet
In A+B Zuordnung der a lgebra ischen Summe der be iden Eingangssignale A und B
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
BESCHREIBUNG DES MENUumlFENSTERS Option
Erlaubt die Anzeige der Systemeinstellungen wie die Zuordnung der Ein- und Ausgaumlnge Daumlmpfung Displaykontrast und Firmware-Version
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B Src
Diese Option erlaubt die Einstellung des Audio-Signaltyps am Eingang
Analoge Audiosignale (Eingaumlnge A und B)
Digitale Audiosignale (Eingang AESEBU)
DigOut Src
An In =Audiosignale an den analogen Eingaumlngen
Dig In =Audiosignale am digitalen Eingang
OUT 1-2 =Audiosignale an den Ausgaumlngen 1 und 2
OUT 3-4 =Audiosignale an den Ausgaumlngen 3 und 4
OUT 5-6 =Audiosignale an den Ausgaumlngen 5 und 6
Input Mode
An In
Dig In
Indip =
Linked =
Diese Option erlaubt die Audioquelle zu waumlhlen die fuumlr den Steckverbinder AESEBU OUT (digitaler Ausgang) bestimmt ist
Erlaubt die Eingaumlnge zu konfigurieren
Sie sind unabhaumlngig und selbststaumlndig sie unterliegen keinen Verpflichtungen untereinander Sie sind verbunden und funktionieren im Stereo-Modus
Die Kompressoren Filter Verzoumlgerungen die Lautstaumlrke sind bei beiden Kanaumllen identisch
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
39
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
40
Atten PadZeigt an wie der Wahlschalter -6 dB auf der Ruumlckseite eingestellt ist [Ref 5] Dieser Wahlschalter muss aktiviert werden wenn das Level an den analogen Eingaumlngen zu hoch ist Der Wahlschalter wird uumlber die Taste aktiviert im Menuuml gibt es nur eine Anzeige
0dB = Wahlschalter nicht aktiviert
-6dB = Wahlschalter aktiviert
Contrast
10 heller 60 dunkler 100
Fw Vers
Die Eingangssignale sind dieselben wie die Eingangsquelle
Die Eingangssignale werden vom internen Prozessor um -6 dB gedaumlmpft
Erlaubt den Kontrast des LCD-Displays einzustellen um den Unterschied der Helligkeit auf den Installationsort auszurichten Ein deutlicheres Display erlaubt auf korrekte und schnelle Weise innerhalb der Menuumls zu surfenDie Hersteller-Einstellung am Ausgang liegt bei 60
Zeigt die Firmware-Version des Prozessors an
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
41
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
42
TECHNISCHE DATEN
Antwort in FrequenzDynamische GammaCMMRCrosstalkDistorsion
ProzessorFrequenz der DatenausarbeitungAnaloge Converter Verzoumlgerung der VerteilungSpeicherung der Konfigurationen
DisplayTastenBedienungen
Analoger Eingang ndeg2 x XLR (3-poliger Female Stecker)Impedanz des Eingangs gt10KOhmMaximales Level +21dBu ohne PAD
+27dBu bei PAD
Impedanz des Ausgangs 50OhmMaximales Level +21dBu Typ symmetrisch
Typ SPDIF-AESEBU (AES3)
Typ Entsprechend dem Standard des Eingang
Typ
Typ
NETZSPANNUNGABMESSUNGEN (BXHXT)GEWICHT
AUDIO-LEISTUNGEN+- 01dB (20 to 30kHz)116dB typgt 60dB (50 to 10kHz)lt -100dB0002 (1kHz +4dBu)
DIGITALE AUDIO-LEISTUNGEN DSP 2856-bit 48KHz24-bit BURR BROWN15ms32 preset
KONTROLLEN LCD GrafikESC - MENU - FUNCTIONS SELECTIONENTER
EIN-AUSGAumlNGE
Analoger Ausgang ndeg6 x XLR (3-poliger Male Stecker)
Digitaler Eingang ndeg1x XLR (3-poliger female Stecker)
Digitaler Ausgang ndeg1x XLR (3-poliger Male Stecker)
Ein-Ausgang Rdnet ndeg2 x XLR RJ45 (kabel CAT 5) USB Typ B
KONTROLLPARAMETER AUDIOStaumlrke -80dB a +20dB step 01dBVerzoumlgerung Eingang 0 a 729mS step 01 mS
Ausgang 0 a 340mS step 01mSPhasenrotation 0deg - 180deg
KOMPRESSIONSchwelle -80dB a +20dB step 01dBVerhaumlltnis 11 a Inf1 step 001Staumlrke am Ausgang 0dB a 40dB step 01dBAnschlusszeit 1mS a 1000mS step 01mSReleasezeit 1mS a 1000mS step 01mSBeibehaltungszeit 1mS a 1000mS step 01mS
EQUALIZER12 Equalizer fuumlr jeden Ein- und Ausgang
PEQ (parametrischer) Hi-shelf Lo-sheftFrequenz 20Hz a 20KHz step 1HzStaumlrke -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (lediglich PEQ)
FILTER CROSSOVERFilter Linkwitz Riley
HP HochdurchgangsfilterLP Bassdurchgangsfilter
Neigung 12dBoct - 24dBoct - 48dBoctSchnittfrequenz 5Hz a 20KHz step 1Hz
Full-range 100-240Vac 50-60Hz430482x43x130mm 19Kg
AnmerkungenSpezifikationen unterliegen Aumlnderungen ohne Vorankuumlndigung
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
INTRODUCTIONAC26N est un processeur audio numeacuterique pour la gestion de leacutequipement audio conccedilu pour des installations fixes et mobiles Il fonctionne selon une technologie de pointe avec des processeurs agrave 2856bits et des convertisseurs ADDA agrave 24-bits hautes performances Les fonctions du processeur sont les niveaux dentreacutee et de sortie le deacutelai (delay) la polariteacute 12 bandes deacutegalisation par canal dentreacutee et de sortie diffeacuterentes seacutelections de croisement (crossover) et un limiteur hautes performances Le controcircle des filtres a une reacutesolution de 1Hz Les entreacutees et les sorties peuvent ecirctre programmeacutees en plusieurs configurations pour satisfaire tous les besoins AC26N peut ecirctre controcircleacute en temps reacuteel et tous les paramegravetres peuvent ecirctre configureacutes depuis le pupitre frontale et par ordinateur avec interface graphique intuitive accessible via le logiciel laquoDVA Networkraquo et une connexion de reacuteseau deacutedieacutee RDnet ou USBLa mise agrave jour du logiciel pour lUniteacute centrale et DSP par ordinateur portable permet de maintenir le dispositif actualiseacute Il est possible denregistrer et de rappeler 32 configurations preacute-eacutequipeacutees de configuration
Contenu de lemballage - AC26N - Mode demploi- CD logiciel- Cacircble dalimentation
Caracteacuteristiques- 2 entreacutees et 6 sorties avec adressage flexible- Entreacutee et sortie steacutereacuteo AESEBU adressables - DSP 2856-bit- Convertisseurs AD BURR BWOWN 24-bit hautes performances- Freacutequence de reacutesolution des filtres 1 Hz - 12 eacutegaliseurs parameacutetriques pour chaque entreacutee et sortie- 2 filtres de croisement par sortie avec pente seacutelectionnable agrave 122448dBoct- DRC agrave configuration multiple hautes performances pour configuration limiteur
compression pour chaque entreacutee et sortie- Niveau reacuteglable en dB polariteacute et deacutelai pour chaque entreacutee et sortie- Mise agrave jour du micrologiciel par lordinateur- Affichage graphique agrave cristaux liquides- 32 preacutereacuteglages enregistrables par lutilisateur- Interface USB pour le controcircle et la configuration par ordinateur- Interface RDnet permettant de controcircler jusquagrave 256 dispositifs agrave distance
PC
PC
RDNETcontrol(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FONCTIONS DE LA FACE AVANT
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
COMMANDES ET FONCTIONS1) AFFICHAGE
Laffichage graphique agrave cristaux liquides permet de visualiser et deacutediter les informations de lAC26N sans utiliser lordinateur Le contraste peut ecirctre configureacute dans le menu principal
2) MANETTE Functions Selector et Push EnterCe controcircle permet de se deacuteplacer de seacutelectionner et de modifier les paramegravetres dans les menus affichables agrave leacutecranRotation de la manette (Functions Selectors)- permet de se deacuteplacer sur les diffeacuterentes pages du menu - permet de modifier les paramegravetres seacutelectionneacutesPression de la manette (Push Enter)- permet de seacutelectionnervalider les paramegravetres
3) Bouton ESC Ce controcircle permet de quitter les menus afficheacutes ou de revenir agrave la visualisation preacuteceacutedente
4) Bouton Menu Ce controcircle permet dacceacuteder directement au menu principal
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
Fra
nccedilais
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
43
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
Fra
nccedilais
44
DVA Network
AC26N est eacutequipeacute dune interface de reacuteseau proprieacutetaire deacutenommeacutee RDNET au moyen de laquelle il est possible de sinterfacer agrave lordinateur agrave travers un peacuteripheacuterique (RDNET control)
Pour cela un protocole de communication a eacuteteacute deacuteveloppeacute avec lequel il est possible de recevoir et denvoyer les donneacutees ce branchement permet de faire le monitorage en temps reacuteel des paramegravetres du diffuseur comme puissance de sortie tempeacuterature de lamplificateur eacutetat du limiteur etc Il est aussi possible de seacutelectionner diffeacuterentes eacutegalisations ou den creacuteer de nouvelles et de reacutegler les niveaux de volume souhaiteacutes au moyen dun plug-in approprieacute
On conseille de teacuteleacutecharger gratuitement le logiciel DVA Network directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
DVA USB Manager
On conseille de teacuteleacutecharger gratuitement le logiciel DVA USB Manager directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
Le micrologiciel du module amplificateur peut ecirctre remis agrave jour par le port USBPour rendre cette mise agrave jour possible et facile un programme speacutecifique a eacuteteacute deacuteveloppeacute
DOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
CONNEXIONS DU PANNEAU ARRIEgraveRE
1586 75 141210 11 13 169 17
14) Connecteur ldquo USBrdquoCe connecteur USB (type B) permet de connecter le processeur agrave un ordinateur pour le controcircle et la mise agrave jour du micrologiciel via un programme deacutedieacute (DVA Network)
15) PRISE DALIMENTATION MAINSPermet la connexion du cacircble dalimentation fourni de seacuterie
16) PORTE-FUSIBLE FUSELogement pour fusible de ligne
17) INTERRUPTEUR GENERAL POWERLinterrupteur permet de mettre en marche ou deacuteteindre le controcircleur audio
COMMANDES ET FONCTIONS
5) SELECTEUR ldquo-6dBrdquoLe seacutelecteur permet de reacuteduire de 6dB les niveaux dentreacutee analogiques XLR [6] tout en compensant les niveaux eacuteleveacutes de sortie des meacutelangeurs ou dautres dispositifs audio Quand la barre du niveau de signal des entreacutees sur laffichage [1] reste au maximum cela indique que le niveau du signal entrant est eacuteleveacute Il est alors conseilleacute dutiliser latteacutenuation -6dBIl est possible de veacuterifier quand le seacutelecteur est activeacute par le menu Option
6) CONNECTEURS DENTREE ldquoArdquo ET ldquoBrdquoEntreacutees eacutequilibreacutees au niveau de la ligneIls sont en mesure daccepter des connecteurs XLR macircles
7) CONNECTEURS DE SORTIE ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo ET ldquo6rdquoSorties eacutequilibreacutees au niveau de la ligne Ils sont en mesure daccepter des connecteurs XLR femelles
Prendre garde agrave brancher convenablement les sorties sur les diffuseurs ou les amplificateurs en fonction des configurations de chaque canal pour eacuteviter des deacutegacircts et des problegravemes de fonctionnement
Section ldquoAESEBUrdquo
8) CONNECTEUR DENTREE INOutre les entreacutees audio analogiques une entreacutee audio numeacuterique SPDIF-AESEBU (AES3) a eacuteteacute preacutevue et peut ecirctre seacutelectionneacutee par le menu de setupLentreacutee requiert une connexion eacutequilibreacutee en utilisant un connecteur XLR avec un cacircble agrave 3 conducteurs de 110ohm torsadeacute
9) CONNECTEUR DE SORTIE OUTCe connecteur permet de relancer le signal audio dans les entreacutees analogiques ou numeacuteriques ou sur les sorties La source doit ecirctre reacutegleacutee par le menu OptionLa connexion sera conforme agrave la mecircme norme que lentreacutee [reacutef8]
Section ldquoRDNETrdquo
10) CONNECTEUR DENTREE DATA INPUTConnecteur RJ45 entreacutee de donneacutees
11) CONNECTEUR DE SORTIE DATA LINKConnecteur RJ45 sortie de donneacutees pour la connexion de seacuterie en cascade
12) VOYANT LUMINEUX ONCe voyant de couleur verte sallume uniquement quand lAC26N a reconnu et est connecteacute agrave luniteacute principale RDNET par lordinateur
13) VOYANT LUMINEUX ACTIVECe voyant de couleur jaune clignote quand une transmission des donneacutees est active entre RDNET et le dispositif
PUSH
P SHU
SHPU
P SHU
PUSH
CONNEXIONS
Audio analogiquesLes connexions eacutequilibreacutees permettent de reacuteduire au minimum le bruit provoqueacute par les cacircbles et dutiliser de longs cacircblesCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLe connecteur XLR doit ecirctre brancheacute avec la broche 1 agrave la masse la broche 2 au chaud (+) et la broche 3 au froid (-) En cas de cacircble blindeacute brancher le blindage agrave la broche 1Les cacircbles de connexion XLR-XLR et XLR-Jack14(63mm) peuvent semployer pour la connexion agrave lAC26N
12
3
Entreacutee
Entreacutee
XLR - femme
XLR - femme
1 2
3
Sortie
Sortie
XLR - Macircle
XLR - Macircle
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2 = Point chaudPhase +VE
Broche 3 =Point froidPhase -VE
Broche 3 =Point froidPhase -VE
Anneau
Manchon
Pointe Point chaudPhase +VE
Anneau = Point froidPhase -VE
ManchonB Masselindeacute
Pointe
Les connexions deacuteseacutequilibreacutees peuvent semployer mecircme si le bruit provoqueacute par les cacircbles augmente Les cacircbles ne peuvent deacutepasser 5m de longCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLes connexions deacuteseacutequilibreacutees peuvent abaisser le niveau du signal entrant de 6dB Pour remeacutedier agrave cet inconveacutenient il faut brancher la broche 3 agrave la masse mecircme si cela augmente le bruit
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
45
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
46
12
3
1 2
3
Pointe Manchon
Pointe = Signal
Broche 3 = Link to Pin 1
Broche 3 = Link to Pin 1
ManchonB Masselindeacute
Audio numeacuteriques (AESEBU)
AESEBU (protocole AES3) est une entreacutee eacutequilibreacutee isoleacutee eacutelectriquement agrave laide dun transformateur Elle permet demployer deux canaux audio dans un seul cacircble bipolaire blindeacute Les caracteacuteristiques du cacircble doivent ecirctre de 3 pocircles impeacutedance 100ohm torsadeacute et blindeacute avec connecteur XLR (AES3 standard)
RJ 45
|1|2|3|4|5|6|7|8|
RDnet
Chaque port RDNet des Control 2 et Control 8 peut ecirctre brancheacute agrave un maximum de 32 dispositifs compatibles placeacutes en cascade Dans lexemple suivant le port de luniteacute de controcircle RDNET CONTROL 2 est relieacute agrave lentreacutee DATA INPUT dun AC26N dont la sortie parallegravele DATA LINK est envoyeacutee agrave lentreacutee de lAC26N successif Dans lexemple [n] est un nombre compris entre 3 et 32 (limite maximale des dispositifs que lon peut relier agrave un sous-reacuteseau)
La longueur totale du cacircble CAT5 dun sous-reacuteseau NE peut PAS deacutepasser 900 megravetres
Le connecteur doit ecirctre relieacute comme 1 ndash disponible pour dautres fonctions (par exemple audio +) 2 ndash disponible pour dautres fonctions (par exemple audio )3 ndash disponible pour dautres fonctions (par exemple masse analogique)4 ndash masse numeacuterique5 ndash masse numeacuterique6 ndash disponible pour dautres fonctions (par exemple alimentation)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
MISE EN MARCHE
Lors de la mise en marche du dispositif linitialisation deacutebute et dure quelques secondes Leacutecran affiche le modegravele le logo et la barre de progression du chargement du programme
En fin de processus dinstallation leacutecran affiche la fenecirctre du menu Meters Pour connaicirctre les indications en deacutetail consulter le paragraphe DESCRIPTION FENETRE MENU Meters
LAC26N est precirct agrave lemploi
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION ET VISUALISATION
Pour entrer dans la fenecirctre du menu principal il faut pousser sur la touche MENU ( ) agrave lavant du dispositifDune page quelconque du menu en poussant sur la touche ESCrdquo ( ) on revient automatiquement sur la page-eacutecran preacuteceacutedente
MENU PRINCIPAL
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Le processeur contient six menus Ils montrent etou configurent les paramegravetres du systegravemeLes menus principaux sont
Meters Visualisation des niveaux des entreacutees et des sorties visualisation du programme utiliseacute et eacutetat mute rapide
Preset Meacutemoriser enregistrer et eacuteliminer les configurations du systegraveme
Matrix seacutelectionner les sorties en fonction du signal entrant
Ch Job configuration de chaque signal
X-Over configurer les freacutequences de coupure et les types de filtres pour chaque sortie
Option attribution des entreacutees et des sorties contraste daffichage la version du micrologiciel les entreacutees et dautres options
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
47
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
48
DESCRIPTION DE LA FENETRE MENU Metersrdquo
Cette fenecirctre permet de visualiser les configurations et leacutetat geacuteneacuteral des entreacutees et des sorties la version du programme utiliseacute son eacutetat et le mode de pilotage du systegraveme
Les menus et les options afficheacutees peuvent se seacutelectionner en tournant la manette ldquoFUNCTIONS SETECTORrdquo ( ) Pour avoir accegraves agrave linteacuterieur de la seacutelection il faut mettre le paramegravetre souhaiteacute en eacutevidence et pousser sur la manette ldquoPush Enterrdquo ( | ) Il faut en faire de mecircme pour seacutelectionner etou modifier les options dans les commandes du menu
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositifAvec des signaux dentreacutee numeacuteriques les indications ldquoArdquo et ldquoBrdquo correspondent agrave lentreacuteeEn tournant la manette ldquoFUNCTIONS SELECTORrdquo [2] on fait deacutefiler en mode cyclique les canaux dentreacutee de sortie et lindication de mute geacuteneacuteral (d) le canal seacutelectionneacute est mis en eacutevidence
b) BARRE DE NIVEAU DE COMPRESSIONMUTE CANAL
COMPRESSION DE SIGNALLa compression du signal est visualiseacutee par le deacutefilement de la barre de droite de haut en bas
MUTE Chaque canal peut ecirctre placeacute en mute Seacutelectionner le canal et pousser sur la manette ldquoPush Enterrdquo [2] pour valider le changement deacutetat Lindication du canal sera remplaceacutee par la lettre M et la barre sera totalement mise en eacutevidencePour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterations
c) BARRE DE NIVEAU DE SIGNALLindication du niveau de chaque canal est signaleacutee par le deacutefilement de la barre de gauche
d) MUTE GENERALIl est possible de mettre simultaneacutement toutes les entreacutees et les sorties en mute Tourner la manette ldquoFUNCTIONS SELECTORrdquo seacutelectionner la lettre M et pousser sur la manette Push EnterPour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterationsLe mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) MODES DE COMMANDEIl affiche le mode dutilisation etou les dispositifs qui sont relieacutes agrave lAC26N
Local = utilisation autonome Aucune connexion agrave un dispositif exteacuterieur
NET = relieacute directement au reacuteseau deacutedieacute RDNet et agrave lordinateur
USB = relieacute directement agrave un ordinateur par cacircble USB
f) INDICATION DETAT DE PARAMETRAGECette indication permet de constater si un ou plusieurs paramegravetre(s) du programme chargeacute aont eacuteteacute modifieacute(s) par rapport au dernier sauvetage
= programme dorigine
= programme avec des paramegravetres modifieacutes
g) PROGRAMME CONFIGURELe chiffre indique le programme chargeacute et utiliseacute par le systegraveme agrave lemplacement de sauvetage Consulter le menu de Preset pour de plus amples deacutetails
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
DESCRIPTION DE LA FENETRE MENU Ch Job
Cette fenecirctre permet dafficher la configuration de chaque canal
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) NIVEAU DU SIGNALIndique le gain du signal Laugmentation de lintensiteacute dun signal est libelleacutee en deacutecibel (dB) Le paramegravetre peut ecirctre seacutelectionneacute de -8000dB agrave +2000dB avec des pas de 001dB Une augmentation de 6dB est eacutegale approximativement au redoublement agrave leacutechelle lineacuteaire du niveau du signal sous tensionAvec un gain supeacuterieur agrave 0dB le signal est amplifieacute tandis quavec un gain infeacuterieur agrave 0dB le signal est atteacutenueacute
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
49
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
50
c) DELAI DU SIGNAL (DELAY)Le signal audio reproduit peut ecirctre retardeacute pour permettre lalignement acoustique Cela compense les diffeacuterentes positions des diffuseurs pendant linstallation et la reproduction sonore Il se libelle en mS Le paramegravetre peut ecirctre seacutelectionneacute de 00mS agrave 729mS avec un pas de 01mSPour aligner un signal audio il est possible dutiliser la formule suivante
Deacutelai = (GAPx1000)344
Deacutelai = ms (en millisecondes)GAP = distance du diffuseur du point de reacutefeacuterence (en megravetres)Vitesse du son = 344ms
d) MUTEChaque canal peut ecirctre placeacute en mute La mecircme commande peut ecirctre activeacutee dans la fenecirctre du menu meters NB Le mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) PhasePermet la rotation de phase de 180deg par rapport au signal entrantCette rotation permet loptimisation surtout des basses freacutequences dans les installations complexes
f) EGALISATIONCette commande ouvre la fenecirctre du menu deacutegalisation de chaque canal Elle sert surtout pour corriger une ou plusieurs freacutequences qui doivent ecirctre atteacutenueacutees ou augmenteacutees
M M
LAC26N gegravere 12 filtres par canal dentreacutee et sortie avec trois types de configurations diffeacuterentes - Leacutegaliseur PEQ (peaking equalizer) est ideacuteal pour identifier isoler et
corriger une seule plage de freacutequences bien deacutetermineacutee Toutes les freacutequences passent mais il augmente ou diminue uniquement celles autour de la freacutequence centrale pour une bande preacutecise et un gain deacutefini
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessus de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessous de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
f Numeacuterotation des 12 filtres disponibles pour cette entreacutee ou cette sortie1
f Le type de filtre est afficheacute 2
Dis Deacutesactiveacute (absent)
PEQ Peaking equlizer
Sh H Filtre high-shelf
Sh L Filtre high-shelf
Exemples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
REMARQUELe paramegravetre Bw deacutetermine le champ de freacutequences adjacent agrave la freacutequence configureacutee ougrave est activeacute le filtre Plus la valeur Bw est eacuteleveacutee plus vaste est le champ de freacutequences (1Bw=1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONCette commande ouvre la fenecirctre du menu de compression de chaque canal
g1) TresholdIdentifie le seuil ougrave commence le rapport de compression La valeur de base 11
g2) RatioIndique le rapport de conversion entre le signal entrant et le signal sortant
g3) Post Gain Attach Release HoldCes donneacutees deacutependent du rapport de conversion que lon veut obtenir - Post Gain est le gain de sortie- Attack est le temps dattaque - Release est le temps de relacircchement- Hold est le temps de maintien
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
52
DESCRIPTION DE LA FENETRE MENU Preset
Cette fenecirctre permet de meacutemoriser jusquagrave 32 configurations dans lAC26NLe fabricant fournit le systegraveme avec un programme configureacute et enregistreacute en position 0 et non susceptible deacutecrasement
032 Elle indique lemplacement de sauvetage de la configurationCe numeacutero apparaicirct dans la fenecirctre Meters en position (g) A tout moment le programme utiliseacute peut ecirctre afficheacute par lutilisateur
Empty Preset Cest le nom qui est associeacute au numeacutero de lemplacement quand aucune configuration (vide) nest enregistreacutee
Local preset Local preset est le nom qui est associeacute au numeacutero de lemplacement quand on enregistre une configuration NB = Il est possible denregistrer une configuration avec lenom souhaiteacute de 16 lettres tout au plus agrave condition que lonutilise linterface via lordinateur
Le nom du programme assigneacute est indiqueacutePour toucher agrave lapplication 3 choix soffrent agrave vous
Save Le programme est enregistreacute en meacutemoire de lAC26N
Del Le programme est effaceacute
Load Le programme est chargeacute et precirct agrave lemploi
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
51
DESCRIPTION DE LA FENETRE MENU X-Over
Cette fenecirctre permet de seacutelectionner un filtre passe bas un filtre passe haut ou par la combinaison des deux de creacuteer un filtre passe bande pour chaque sortieLe filtre actif est un Linkwitz-Riley qui permet de seacutelectionner la pente de 12dBoct 24dBoct ou 48dBoct et sa freacutequence de coupure
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) CANAUX DE SORTIE
Les connecteurs de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) FILTRE CROSSOVERSeacutelectionner le filtre selon les besoins Il est possible de seacutelectionner
Dis Aucun filtre activeacute
HP Filtre passe-haut laisse passer uniquement la partie de signal audio supeacuterieure agrave la freacutequence de coupure
LP Filtre passe-bas laisse passer uniquement la partie de signal audio infeacuterieure agrave la freacutequence de coupure
Configuration du filtre Passe-haut Passe-bas
Rien Dis Dis
Passe-haut HP Dis
Passe-bas Dis LP
Passe-bande HP LP
12dBoct
24dBoct
Hz
dB
Ga
in 48dBoct
12dBoct
24dBoct
Hz
dB
Ga
in
48dBoct
c) PENTE DATTENUATIONSeacutelectionner la pente datteacutenuation du signal audio en fonction de la diminution que lon veut obtenir Plus la pente datteacutenuation est eacuteleveacutee agrave eacutegaliteacute de freacutequence de coupure plus eacuteleveacutee sera la seacutelection du signal Il est possible de seacutelectionner
12 correspond agrave 12dboct
24 correspond agrave 24dboct
48 correspond agrave 48dboct
d) FREQUENCE DE COUPUREElle permet de reacutegler la freacutequence de passage des freacutequences infeacuterieures (filtre passe-bas) ou des freacutequences supeacuterieures (filtre passe-haut) uniquementLe choix de la coupure deacutepend de la reproduction que lon veut obtenirLuniteacute de mesure utiliseacutee est lHz
Hz
Hz
dB
dB
Ga
in
f0
f0
0dB0dB
0dB
-6dB
freacutequence
freacutequence
freacutequence
freacutequence
Ga
in
f0
0dB
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
53
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
54
DESCRIPTION DE LA FENETRE MENU Matrix
Elle permet de seacutelectionner le signal entrant agrave utiliser comme source pour chaque sortie
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) CANAUX DE SORTIEIdentification du canal sortant agrave reacutegler
b) IDENTIFICATIONS DES ENTREESSeacutelectionner le type de signal agrave associer agrave chaque sortie en fonction des besoins Il est possible de seacutelectionner
In A Le signal entrant A est associeacute
In B Le signal entrant B est associeacute
In A+B La somme algeacutebrique des deux signaux entrants A et B est associeacutee
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
DESCRIPTION DE LA FENETRE MENU Option
Permet dafficher les reacuteglages du systegraveme comme lassignation des entreacutees et des sorties latteacutenuation le contraste de laffichage et la version du logiciel
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcCette option permet de reacutegler le type de signal audio entrant
An In =signaux audio analogiques (entreacutees ldquoArdquo et ldquoBrdquo)
Dig In =signaux audio numeacuteriques (entreacutee AESEBU)
DigOut SrcCette option permet de seacutelectionner la source audio qui sera adresseacutee sur le connecteur AESEBU OUT (sortie numeacuterique)
An In = signaux audio des entreacutees analogiques
Dig In =signaux audio sur lentreacutee numeacuterique
OUT 1-2 = signaux audio sur les sorties 1 et 2
OUT 3-4 = signaux audio sur les sorties 3 et 4
OUT 5-6 = signaux audio sur les sorties 5 et 6
Input ModePermet de configurer les entreacutees
Indip = sont indeacutependantes et autonomes Ne sont soumises agrave aucun type de lien
Linked = sont unies et fonctionnent en mode steacutereacuteo Les compresseurs les filtres les deacutelais le volume sont identiques pour les deux canaux
Atten PadIndique le mode de reacuteglage du seacutelecteur ldquo-6dBrdquo placeacute agrave larriegravere [reacutef 5] Il faut activer ce seacutelecteur quand les niveaux dentreacutee analogiques sont trop eacuteleveacutes Le seacutelecteur sactive uniquement par le bouton Dans le menu il sagit dune simple visualisation
0dB = seacutelecteur non activeacute Les signaux dentreacutee sont identiques agrave la source entrante
-6dB = seacutelecteur activeacute Les signaux entrants sont atteacutenueacutes de -6dB par le processeur interne
ContrastIl permet de reacutegler le contraste de laffichage agrave cristaux liquides pour compenser la diffeacuterence de luminositeacute avec le lieu dinstallation Une plus grande clarteacute de laffichage permet de naviguer convenablement et rapidement dans les menusLe reacuteglage agrave la sortie de lusine du fabricant est de 60
10 plus clair 60 plus fonceacute 100
Fw VersIndique la version du logiciel du processeur
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
55
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
56
DONNES TECHINIQUES
PERFORMANCES AUDIOReacuteponse en freacutequence +- 01dB (20 to 30kHz)Plage dynamique 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsion 0002 (1kHz +4dBu)
PERFORMANCES AUDIO NUMERIQUES Processeur DSP 2856-bit Freacutequence de traitement des donneacutees 48KHzConvertisseurs analogiques 24-bit BURR BROWNDeacutelai de propagation 15msMeacutemorisations des configurations 32 preset
CONTROLES Affichage LCD graficoBoutonsCommandes ESC - MENU - FUNCTIONS SELECTION
ENTERENTREESSORTIESEntreacutee analogique ndeg2 x XLR (3 broches femelle)
Impeacutedance dentreacutee gt10KOhmNiveau maximum +21dBu senza PAD
+27dBu con PADSortie analogique ndeg6 x XLR (3 broches macircle )
Impeacutedance de sortie 50OhmNiveau maximum +21dBuType Balanceacute
Entreacutee numeacuterique ndeg1x XLR (3 broches femelle)Type SPDIF-AESEBU (AES3)
Sortie numeacuterique ndeg1x XLR (3 broches macircle )Type conforme agrave la norme de lentreacutee
EntreacuteesSortie Rdnet ndeg2 x XLR RJ45 (cacircble CAT 5)USB Type B
PARAMETRES DE CONTROLE DU SONGain -80dB a +20dB eacutetape 01dBDeacutelai Entreacutee 0 a 729mS eacutetape 01 mS
Sortie 0 a 340mS eacutetape 01mSRotation de phase 0deg - 180deg
COMPRESSIONSeuil -80dB a +20dB eacutetape 01dBRapport 11 a Inf1 eacutetape 001Gain agrave la sortie 0dB a 40dB eacutetape 01dBTemps dattaque 1mS a 1000mS eacutetape 01mSTemps de relacircchement 1mS a 1000mS eacutetape 01mSTemps de maintien 1mS a 1000mS eacutetape 01mS
EGALISEURS12 eacutegaliseurs pour chaque entreacutee et sortieType PEQ (parameacutetrique) Hi-shelf Lo-sheft
Freacutequence 20Hz a 20KHz eacutetape 1HzGain -30dB a +15dB eacutetape 001dBBande 005dB a 2dB eacutetape 001dB (uniquement pour PEQ)
FILTRES CROSSOVERFiltre Linkwitz Riley
Type HF high-shelfLF low-shelf
Pente 12dBoct - 24dBoct - 48dBoctFreacutequence de coupure 5Hz a 20KHz eacutetape 1Hz
ALIMENTATION Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)POIDS 19Kg
Remarques Speacutecifications sujettes agrave modifications sans preacuteavis
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
2 VIE ATTIVO2 WAY ACTIVE
3 VIE PASSIVO3 WAY PASSIVE
L
L
A
A
HIGH L
MID L
LOW HIGHMID RHIGHMID L
LOW L
HIGH R
MID R
LOW R
R
R
B
B
1
1
2
2
3
3
456
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
Menu Matrix configurationMatrix
57 58
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
EROUIG ATRIX TNM
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
OU
TP
UT
1
OU
TP
UT
2
OU
TP
UT
3
OU
TP
UT
4
OU
TP
UT
5
OU
TP
UT
6
AE
S-E
BU
OU
TP
UT
INP
UT
A
AE
S-E
BU
INP
UT
INP
UT
B
D D D D D D
D D
A A A A A A
A SA
MP
LE
RA
TE
CO
NV
A
LIN
KA
BL
E
SC
HE
MA
A B
LO
CC
HI -
BL
OC
K D
IAG
RA
MB
LO
CK
SC
HA
LT
BIL
D -
SC
HE
MA
S F
ON
CT
ION
NE
LS
LINE ARRAY SUB MONO ATTIVO
LINE ARRAY SUB MONO ACTIVEINGRESSI - INPUT
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
L
L
L
A
A
A
AESEBU IN
AESEBU IN
AESEBU IN
AESEBU OUT
AESEBU IN
AESEBU IN
AESEBU OUT
R
R
R
LR
B
B
B
123456
HIGHMID L
HIGHMID L HIGHMID R
HIGHMID R
LOW L LOW R
LAYER
DISPLAY MEMORY
FADER MODE
LAYER
DISPLAY MEMORY
FADER MODE
Ingresso ANALOGICO
ANALOG Input
Collegamento in cascata
Link connections
Ingresso DIGITALE
DIGITAL inputA B
BALANCED AUDIO INPUTS
-6dB
PUSH PUSH
IN OUT
AES EBUPUSH
Oppure
or
Oppure
or
Menu Option configurationOption
Menu Option configurationOption Menu Option configurationOption
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type Analog
AES out An In
Input type Analog
AES out An In
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
59 60
InA-B Src Dig InInA-B Src Dig InInA-B Src An InInA-B Src An In
frequenzaHz
dB
Gu
ad
ag
no
60 200 2800
0dB0dB
-6dB
Esempio di un sistema a 3-vie
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
Out 1 Out 2 Out 3
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Esempio di un sistema a 3-vie
61 62
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
26NAC 26NAC
R TE
DO
R
MO LEU O R CE S
E O TR L A
S O
O C ND I P
P hsuernE t
o su cti nF nel rS e tc o
E CSME UN
IGCHTE OL SN EOBd
ocaL l
M
0
484
467
430
44
31
75
12
7
DIMENSIONI DIMENSIONSABMESSUNGEN DIMENSIONS
13
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
Ita
lian
oIta
lian
oIta
lian
oM
an
ua
le d
rsquous
oM
an
ua
le d
rsquous
o
14
Atten Pad
Indica come egrave impostato il selettore ldquo-6dBrdquo posto sul retro [rif 5] Ersquo necessario attivare questo selettore quando i livelli di ingresso analogici sono troppo elevati Il selettore viene attivato solo tramite il pulsante nel menugrave egrave solo una visualizzazione
0dB = selettore non attivatoI segnali di ingresso sono i medesimi della sorgente in ingresso
-6dB = selettore attivatoI segnali in ingresso vengono attenuati di -6dB dal processore interno
Contrast
Consente di regolare il contrasto del display LCD per compensare la differenza di luminositagrave con il luogo di installazione Una maggiore chiarezza del display permette di navigare allrsquointerno dei menugrave in modo corretto e veloceIl settaggio in uscita dalla ditta produttrice egrave 60
10 piugrave chiaro 60 piugrave scuro 100
Fw Vers
Indica la versione del firmware del processore
SPECIFICHE TECNICHE
PRESTAZIONI AUDIORisposta in frequenza +- 01dB (20 to 30kHz)Gamma dinamica 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsione 0002 (1kHz +4dBu)
PRESTAZIONI AUDIO DIGITALI Processore DSP 2856-bit Frequenza elaborazione dati 48KHzConvertitori analogici 24-bit BURR BROWNRitardo di propagazione 15msMemorizzazioni configurazioni 32 preset
CONTROLLI Diplay LCD graficoPulsantiComandi ESC - MENU - FUNCTIONS SELECTION
ENTER
INGRESSIUSCITEIngresso analogico ndeg2 x XLR (3 poli femmina)
Impedenza di ingresso gt10KOhmLivello massimo +21dBu senza PAD
+27dBu con PADUscita analogica ndeg6 x XLR (3 poli maschio)
Impedenza di uscita 50OhmLivello massimo +21dBu Tipo Bilanciato
Ingresso digitale ndeg1x XLR (3 poli femmina)Tipo SPDIF-AESEBU (AES3)
Uscita digitale ndeg1x XLR (3 poli maschio)Tipo conforme allo standard dellrsquoingresso
IngressiUscita RDnet ndeg2 x XLR RJ45 (cavo CAT 5)USB Tipo B
PARAMETRI CONTROLLO AUDIOGuadagno -80dB a +20dB passo 01dBRitardo
ingresso 0 a 729mS passo 01 mSuscita 0 a 340mS passo 01mS
Rotazione di fase 0deg - 180deg
COMPRESSIONESoglia -80dB a +20dB passo 01dBRapporto 11 a Inf1 passo 001Guadagno in uscita 0dB a 40dB passo 01dBTempo di attacco 1mS a 1000mS passo 01mSTempo di rilascio 1mS a 1000mS passo 01mSTempo di mantenimento 1mS a 1000mS passo 01mS
EQUALIZZATORI12 equalizzatori per ogni ingresso e uscitaTipo PEQ (parametrico) Hi-shelf Lo-sheft
Frequenza 20Hz a 20KHz passo 1HzGuadagno -30dB a +15dB passo 001dBBanda 005dB a 2dB passo 001dB (solo per PEQ)
FILTRI CROSSOVERFiltro Linkwitz Riley
Tipo HP Passa-AltoLP Passa-Basso
Pendenza 12dBoct - 24dBoct - 48dBoctFrequenza di taglio 5Hz a 20KHz passo 1Hz
ALIMENTAZIONE Full-range 100-240Vac 50-60HzDIMENSIONI 430482x43x130mm (LxHxD)PESO 19Kg
Note Specifiche soggette a variazioni senza preavviso
CLASSIFICAZIONE EMIIn accordo alle normative EN 55103 lapparato egrave progettato e idoneo allutilizzo in ambienti Elettromagnetici E3 o inferiori (E2 E1)
INTRODUCTIONAC26N is a digital sound processor for the management of audio systems designed for fixed and touring installations AC26N uses the most modern technology with 2856 bit processors and high performance 24 bits ADDA converters The functions available in the processor are input and output levels delay polarity 12 equalization bands for each input and output channel multiple crossover and high performance limiter The control resolution of the filters is 1Hz Inputs and outputs can be set according to many configurations to meet any need AC26N can be controlled in real time and each one of its parameters can be configured on the front panel and through a computer by means of an intuitive graphical interface accessible through the software DVA Network and a dedicated RDnet or USB network connectionThe CPU and DSP software update via PC allows to keep the device up to date It is possible to save and recall 32 preset configurations
Package Contents- AC26N - Operating manual- Software CD- Power cord
Characteristics- 2 Inputs and 6 Outputs with flexible routing- AESEBU addressable stereo inputs and outputs - 2856 bit DSP- BURR-BROWN high performance 24 bit AD converters- Frequency resolution of the filters 1 Hz - 12 parametric equalizers for each input and output- 2 crossover filters for each output with selectable slope 122448 dBoct- High performance DRC multi configuration for limitercompression configuration of
each input and output- Adjustable level in dB polarity and delay for each input and output- Firmware Update via PC- Graphic LCD Display- 32 pre-sets can be stored by the user- USB interface for configuration and control via computer- RDnet interface that allows to control up to 256 remote devices
PC
PC
RDNET hub(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FUNCTIONS FRONT PANEL
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
CONTROLS AND FUNCTIONS
1) DISPLAYThe graphic LCD display allows to view and edit the AC26N information without a computer The display contrast can be set within the main menu
2) ldquoFunctions Selectorrdquo and ldquoPush Enterrdquo KNOBThis control allows to move select and change the parameters within the displayed menusRotation of the knob (Function Selector)- it allows to browse the menu pages- it allows to change the selected parametersPush the knob (Push Enter)- it allows to selectconfirm the parameters
3) ESC button This control allows to exit the displayed menus or to return to the previous view
4) MENU button This control allows to directly access the main menu
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
En
glis
hE
nglis
hu
ser
man
ual
user
man
ual
16
user
man
ual
user
man
ual
Englis
hE
nglis
h
15
DVA USB Manager
The firmware of the amplifier module can be updated via the USB portTo make this update possible and simple a dedicated program has been developed
It is recommended to download DVA USB Manager free software directly from dB Technologies (wwwdbtechnologiescom) in the special section laquoSoftware amp Controllerraquo
DVA Network
The AC26N is equipped with proprietary network interface called RDNET for PC interface through a device (RDNET control)For this purpose a proprietary communication protocol has been developed for receiving and sending data this connection permits real-time monitoring of the diffuser parameters such as output power amplifier temperature limiter status etc It is also possible to select various equalizations or create new ones set the desired volume levels using the specific plug-in
It is recommended to download DVA Network free software directly from dB Technologies (wwwdbtechnologiescom) in the special section laquoSoftware amp Controllerraquo DOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
REAR PANEL CONNECTIONS
1586 75 141210 11 13 169 17
14) USB connectorThis USB connector (type B) allows to connect the processor to a compute to check and update the firmware via a dedicated program (DVA Network)
15) ldquoMAINSrdquo POWER CONNECTIONIt allows to connect the provided power cord
16) FUSE HOLDER ldquoFUSErdquoMain power supply fuse housing
17) ldquoPOWERrdquo MAIN SWITCHThis switch allows to switch on and off the device
PUSH
P SHU
SHPU
P SHU
PUSH
CONNECTIONS
Analog Audio ConnectionsBalanced connections allow to minimize the cable induced noise so cable can be longerSuch connections may be used both on inputs and outputsXLR connector must be cabled with pin 1 to ground pin 2 to hot (+) and pin 3 to cold (-) With shielded cables connect the shield to pin 1XLR-XLR e XLR-Jack 14(63 mm) connection cables can be used to connect the AC26N
12
3
Input
XLR - female
Pin 3 =NegativeCold-VE Phase
Pin 3 =NegativeCold-VE Phase
1 2
3
Output
XLR - Male
Pin 2 = PositiveHot+VE Phase
Pin 2 = PositiveHot+VE Phase
Pin 2 = PositiveHot+VE Phase
Pin 2 = PositiveHot+VE Phase
Pin 1 =ScreenGroundEarth
Pin 1 =ScreenGroundEarth
Pin 1 =ScreenGroundEarth
Pin 1 =ScreenGroundEarth
Ring
Sleeve
Tip = PositiveHot+VE Phase
Ring = NegativeCold-VE Phase
Sleeve=ScreenGroundEarth
Sleeve=ScreenGroundEarth
Tip
The unbalanced connections can also be used However the cable induced noise increases and cable length must not exceed 5 metersSuch connections may be used both on inputs and outputsUnbalanced connection may lower the level of the input signal up to 6dB in order to overcome this drawback connect pin 3 to ground although this can increase the noise
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
18
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
17
CONTROLS AND FUNCTIONS
5) -6dB SELECTORThis selector allows to reduce all the analog XLR [6] input levels by 6 dB at the same time to compensate for the high output levels on the mixers or other audio devices When the input signal level bar on the display [1] remains always at full scale this means that the input signal level is excessive and a -6 dB attenuation is recommendedIn the Option menu it is possible to check when the selector is activated
6) INPUT CONNECTORS ldquoArdquo AND ldquoBrdquoInputs balanced at line levelCapable to accept XLR male connectors
7) OUTPUT CONNECTORS ldquo1rdquo ldquo2rdquordquo 3rdquo ldquo4rdquo ldquo5rdquo AND ldquo6rdquoOutputs balanced at line level Capable to accept XLR famale connectors
Be careful to correctly connect each output to each speaker or amplifier according to the settings of each channels to avoid damages and malfunctions
ldquoAESEBUrdquo Section
8) INPUT CONNECTORIn addition to the analog audio inputs a SPDIF-AESEBU (AES3) digital audio input is also provided It can be selected via the setup menuSuch input requires a balanced connection trough an XLR connector with a 110 ohm twisted 3-wires cable
9) ldquoOUTrdquo OUTPUT CONNECTORThis connector allows to forward audio signals available at the digital or analog inputs or outputs The source must be set by means of the Option menuThe connection must comply with the same standard of the input [8]
RDNET Section
10) DATA INPUT CONNECTORData input RJ45 connector
11) ldquoDATA LINKrdquo OUTPUT CONNECTORRJ45 connector for data output used for serial link in cascade
12) ldquoONrdquo INDICATOR LIGHTThis green indicator turns on only when the AC26N has recognized the RDNET main unit and it is connected to it via computer
13) ldquoACTIVErdquo INDICATOR LIGHTThis yellow indicator flashes when data transmission between RDNET and the device is active
12
3
Input
XLR - female
1 2
3
Output
XLR - Male
Tip Gambo
Tip= Signal
Pin 3 = Link to Pin 1
Pin 3 = Link to Pin 1
Digital Audio Connections (AESEBU)AESEBU (AES3 protocol) is and a balanced input electrically insulated by means of a transformer It allows carrying two audio channels in a single two-wires shielded cable The cable characteristics are twisted 3 poles impedance 100 ohm shielded equipped with XLR connector (AES3 standard)
RDnetEach RDNet port on Control 2 and Control 8 can be connected to maximum 32 cascade-connected compatible devices In the example below the control unit RDNET CONTROL 2 port is connected to the DATA INPUT of an AC 26N whose parallel DATA LINK output is sent to the input of the next AC26N In the example [n] is a number between 3 and 32 (maximum limit for the devices connected to a sub-network)
RJ 45
|1|2|3|4|5|6|7|8|
The overall length of a CAT5 sub-network cable cannot exceed 900 meters
The connector must be connected as follows
1 - Available for other functions (for example audio +) 2 - Available for other functions (for example audio -)3 - Available for other functions (for example analog ground)4 - digital ground5 - digital ground6 - Available for other functions (for example power supply)7 - RS 485 A8 - RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
POWER ON
When the device is turned on the initialization procedure starts It lasts few seconds The display shows the device model the company logo and a program loading progress bar
At the end of the installation process the display shows the Meters menu For further details about the indications refer to the paragraph MENU DESCRIPTION - METERS
AC26N is now ready for use
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION AND DISPLAY
To access the main menu window press the MENU key located on the device front panelIn any page of the menu press the ESC button to return to the previous screen
MAIN MENU
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
There are six menus in the processor They show andor configure the system parametersThe main menus are
Meters Input and output levels display program in progress display quick muting
Preset Store save and delete the system configurations
Matrix Select the outputs according to the input signal
Ch Job Configuration of each individual channel
X-Over Configuration of the cut-off frequency and the types of filters for each output
Option Assignment of the inputs and outputs display contrast firmware version inputs and other options
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
20
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
19
The menus and the individual options displayed can be selected by rotating the knob ldquoFUNCTION SELECTORrdquo ( ) To access the selection highlight the desired parameter and press the ldquoPush Enterrdquo ( | ) knobThe same procedure should be adoptd to select andor change the options inside each menu entry
MENU DESCRIPTION - ldquoMetersrdquo
This window allows to view the configuration and the general conditions of the inputs and outputs the version of the program used the program status and how the system is driven
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) INPUT AND OUTPUT CHANNELSThe input and output connectors are identified by the same information provided on the screen printing located on the device rear sideWith digital input signals the indications A and B concern the inputBy rotating the knob FUNCTION SELECTOR [2] input channels output channels and general muting indications are cyclically scrolled (d) the selected channel is highlighted
b) BAR COMPRESSION LEVEL CHANNEL MUTING
SIGNAL COMPRESSIONSignal compression is displayed by the vertical scrolling (top to down) of the right bar
MUTE Each channel can be individually muted Select the channel and press the Push Enter knob [2] to confirm the change of status The indication of the channel will be replaced by the letter M and the bar will be completely highlightedTo restore normal operation repeat the actions described above
c) SIGNAL LEVEL BARThe level indication for each channel is provided by scrolling the left bar
d) GENERAL MUTINGIt is possible to mute all the inputs and outputs simultaneously Rotate the knob FUNCTION SELECTOR select the letter M and press the Push Enter knobTo restore normal operation repeat the actions described aboveThe general mute has the highest priority with respect to the muting of individual channels
e) CONTROL MODEIt shows how the AC26N is used andor to which devices it is connected
Local = stand-alone usage No connection to an external device
NET = directly connected to dedicated RDnet network and to computer
USB = directly connected to another computer via USB cable
f) SETTING STATUS INDICATIONThis indication shows if the loaded program was amended in one or more parameters with respect to the last saving operation
= original program
= program with modified parameters
g) SET PROGRAMThe number shows the program that is loaded and used by the system with reference to the saving position Refer to the ldquoPresetrdquo menu for further details
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
MENU DESCRIPTION - CH JOB
This window allows to view the configuration of each individual channel
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) INPUT AND OUTPUT CHANNELSThe input and output connectors are identified by the same information provided on the screen printing located on the device rear side
b) SIGNAL LEVELIt shows the signal gain The increased signal intensity is expressed in decibels (dB) Such parameter can be selected in the range from -8000 dB to +2000 dB in steps of 001 dB An increase of 6 dB is approximately equal to doubling - in a linear scale - the signal voltage levelIf the gain exceeds 0 dB the signal is amplified while if the gain is lower than 0 dB the signal is attenuated
c) SIGNAL DELAYThe reproduced audio signal may be delayed to perform an acoustic alignment This compensates for the different positions of the speakers during the installation and the sound reproduction it is expressed in ms The parameter can be selected in the range from 00 ms to 729 ms in steps of 01 msThe following formula can be used to align an audio signal
Delay = (GAPx1000)344
Delay = ms (in milliseconds)GAP = distance between speaker and reference point (in meters)Speed of sound = 344 ms
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
22
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
21
d) MUTEEach channel can be individually muted The same command can be activated in the Meters Menu
NOTE The general mute has the highest priority with respect to the muting of individual channels
e) PhaseIt performs a phase rotation of 180deg with respect to the input signalSuch phase rotation allows the optimization in special way for low frequencies in complex installations
M M
f) EQUALIZATIONThis control opens the menu controlling the single channel equalization It is mainly used to correct one or more frequencies that must be reduced or increased
The AC26N manages 12 filters for each individual channel input and output with three different kinds of configuration
- PEQ Equaliser (peaking equalizer) ideal to identify isolate and correct only a certain range of frequencies All frequencies pass only those around the centre frequency are increased and decreased for a given bandwidth and set gain
- High-shelf Equalizer All frequencies pass but frequencies above the selected cut-off frequency are increased or attenuated by the given gain
- Low-shelf Equalizer All frequencies pass but frequencies below the selected cut-off frequency are increased or attenuated by the given gain
f Numbering of the 12 available filters for the specific input or output1
f Displays the kind of filter2
Dis Switched off (not present)
PEQ Peaking equlizer
Sh H High-shelf Filter
Sh L Low-shelf Filter
Examples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
NOTE
The parameter Bw defines the range of frequencies close to the set frequency where the filter is activated the greater the value of Bw the wider is the frequencies range (1 Bw = 1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONThis control opens the menu controlling the compression for the single channel
g1) ThresholdIdentifies the starting threshold for the compression ratio Base value 11
g2) RatioIndicates the conversion ratio between input and output signal
g3) Post Gain Attach Release HoldThese data are in function of the conversion ratio to achieve Post Gain is the output gain Attack is the attack time Release is the release time Hold is the holding time
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
24
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
23
MENU DESCRIPTION - PRESET
This window allows to store up to 32 configurations in the AC26NThe manufacturer provides the system with a program set and saved in position 0 that is not possible to overwrite
032 Indicates the location where the configuration is savedThis number also appears in the window Meters in position (g) The program in use can be displayed at any time by the user
Empty Preset It is the name associated with the location number when no setting is saved (empty)
Local preset It is the name associated with the location number when a setting is saved NOTE = It is possible to save a setting with the desired name up to 16 letters only via the computer interface
When a program is selected the following window is displayed
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
The name of the assigned program is displayed3 possible choices are available when working on the application
Save The program is saved in the AC 26N memory
Del The program is deleted
Load The program is loaded and ready to be used
MENU DESCRIPTION - X-OVER
This window allows to select for each output a low pass filter a high pass filter or create a band-pass filter via the combination of bothThe available filter is a Linkwitz-Riley where it is possible to select slopes of 12 dBoct 24 dBoct or 48 dBoct and their cut-off frequency
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) OUTPUT CHANNELS
The output connectors are identified by the same information provided on the screen printing located on the device rear side
b) CROSSOVER FILTERSelect the filter according to needs It is possible to select
Dis No filter enabled
HP High-pass filter set it to allow only the part of audio signal above the cut-off frequency
LP Low-pass filter set to allow only the part of audio signal below the cut-off frequency
Filter configuration Low-pass High-pass
Nothing Dis Dis
High-pass HP Dis
Low-pass Dis LP
Band-pass HP LP
12dBoct
24dBoct
Hz
dB
48dBoct
12dBoct
24dBoct
frequency
frequency
frequency
frequency
Hz
dB
48dBoct
c) ATTENUATION SLOPESelect the attenuation slope of the audio signal on the basis of the desired attenuation The higher the attenuation slope at the same cut-off frequency the greater the signal selection It is possible to select
12 equal to 12 dBoct
24 equal to 24 dBoct
48 equal to 48 dBoct
d) CUT-OFF FREQUENCYTo set the passing frequency for the lower frequencies only (low-pass filter) or the higher frequencies only (high-pass filter)The choice of the cut-off depends on the desired sound reproductionThe unit of measurement used is Hz
Hz
Hz
dB
dB
Ga
inG
ain
Ga
inG
ain
f0
f0
0dB0dB
0dB
-6dB
-6dB
0dB
0dB
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
26
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
25
MENU DESCRIPTION - MATRIX
For each output it allows to select the input signal to use as the source
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) OUTPUT CHANNELSIdentification of the output channel to set
b) IDENTIFICATIONS OF THE INPUTSIt selects the type of signal to match each output as needed It is possible to select
In A Associated with the input signal ldquoArdquo
In B Associated with the input signal ldquoBrdquo
In A+B Associated with the algebraic sum of the two input signals ldquoArdquo and ldquoBrdquo
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
MENU DESCRIPTION - OPTION
Allows to display the system settings such as the allocation of the inputs and outputs attenuation display contrast and firmware version
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcThis option allows to set the type of input audio signal
An In = Analog audio signals (inputs A and B)
DigIn = Digital audio signals (AESEBU input)
DigOut SrcThis option allows to select the audio source that will be forwarded to the connector AESEBU OUT (digital output)
An In = Audio signals available at analog inputs
Dig In = Audio signals available at digital inputs
OUT 1-2 = Audio signals available on outputs 1 and 2
OUT 3-4 = Audio signals available on outputs 3 and 4
OUT 5-6 = Audio signals available on outputs 5 and 6
Input ModeIt allows to configure the inputs
Indip = They are independent not subject to constraints of any kind between them
Linked = They are connected and work in stereo mode Compressors filters delays volume are identical for the two channels
Atten PadIt shows how to set the -6 dB switch located on the rear side [Ref 5] It is necessary to activate this selector when the analog input levels are too high The selector can be activated only by means of the button the menu is for display only
0 dB = Selector not activated The input signals are the same as the input source
-6 dB = Selector activated The input signals are attenuated by -6 dB with reference to the inner
processor
ContrastAllows to adjust the LCD display contrast to compensate for the brightness difference at the installation sites Greater display brightness allows to navigate correctly and quickly within the menuThe manufacturer output setting is 60
10 More bright 60 More dark 100
Fw VersIt shows the processor firmware version
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
28
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
27
TECHINICAL SPECIFICATION
AUDIO PERFORMANCEFrequency Response +- 01dB (20 to 30kHz)Dynamic Range 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistortion 0002 (1kHz +4dBu)
DIGITAL AUDIO PERFORMANCE Processor DSP 2856-bit Data processing Frequency 24-bit BURR BROWNAnalog converters 24-bit BURR BROWNPropagation Delay 15msStoring configurations 32 preset
CONTROLS Display LCD graficoButtonsControls ESC - MENU - FUNCTIONS SELECTION
ENTERINPUTSOUTPUTSAnalog Input ndeg2 x XLR (3 pole female)
Input impedance gt10KOhmMaximum Level +21dBu senza PAD
+27dBu con PADAnalog Output ndeg6 x XLR (3 pole male)
Output impedance 50OhmMaximum Level +21dBu Type Balanced
Digital Input ndeg1x XLR (3 pole female)Type SPDIF-AESEBU (AES3)
Digital Output ndeg1x XLR (3 pole male)Type Compliant with the input standard
RDnet InputsOutput ndeg2 x XLR RJ45 (CAT 5 cable)USB Tipo B
SOUND CONTROL PARAMETERSGain -80dB a +20dB step 01dBDelay
Input 0 a 729mS step 01 mSOutput 0 a 340mS step 01mSPhase Rotation 0deg - 180deg
COMPRESSIONThreshold -80dB a +20dB step 01dBRatio 11 a Inf1 step 001Output gain 0dB a 40dB step 01dBAttack time 1mS a 1000mS step 01mSRelease time 1mS a 1000mS step 01mSHold time 1mS a 1000mS step 01mS
EQUALIZERS12 equalizers for each input and outputType PEQ (parametrico) Hi-shelf Lo-sheft
Frequency 20Hz a 20KHz step 1HzGain -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (only with PEQ)
CROSSOVER FILTERSFilter Linkwitz Riley
Type HP High-pass LP Low-pass
Slope 12dBoct - 24dBoct - 48dBoctCUT-OFF FREQUENCY 5Hz a 20KHz passo 1Hz
POWER SUPPLY Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)
1719x17x51 inch (WxHxD)WEIGHT 19Kg
(42 lbs)Note Specifications subject to change without notice
EMI CLASSIFICATIONAccording to the standards EN 55103 this equipment is designed and suitable to operate in E3 (or lower E2 E1) Electromagnetic environments
EINLEITUNG
Verpackungsinhalt
Eigenschaften
AC26N ist ein digitaler Audio-Prozessor fuumlr die Verwaltung von Audio-Systemen der fuumlr feste und mobile Installationen entwickelt wurde AC26N benutzt die modernste Technologie mit 2856 bit-Prozessoren und 24-bit-ADDA-Wandlern mit hoher Leistungsfaumlhigkeit Die verfuumlgbaren Funktionen des Prozessors sind Ein- und Ausgangsstufen Verzoumlgerung (delay) Polaritaumlt 12 Equalizer-Frequenzen fuumlr Ein- und Ausgangskanal viele Crossover-Wahlmoumlglichkeiten und Limiter mit hoher Leistung Die Filter-Kontrolle hat eine Aufloumlsung von 1 Hz Die Ein- und Ausgaumlnge koumlnnen mit unterschiedlichen Einstellungen geregelt werden um allen Anforderungen gerecht zu werden AC26N kann in Echtzeit kontrolliert werden und jeder Parameter kann am Frontpaneel und vom Computer mit intuitiver graphischer Schnittstelle mittels Software DVA Network zugaumlnglich und einer Netzverbindung RDnet oder uumlber USB eingestellt werdenDie SW-Aktualisierung fuumlr CPU und DSP uumlber PC erlaubt die Vorrichtung auf dem aktuellen Stand zu halten Man kann 32 vorgesehene Konfigurationen speichern und aufrufen
- AC26N - Bedienungsanleitung- Software-CD- Versorgungskabel
- 2 Ein- und 6 Ausgaumlnge mit flexibler Adressierung- Adressierbarer Stereo-Ein- und Ausgang AESEBU - DSP 2856-bit- AD-Wandler BURR BROWN 24-bit mit hoher Leistungsfaumlhigkeit- Aufloumlsungsfrequenz der Filter 1 Hz - 12 parametrische Equalizer fuumlr jeden Ein- und Ausgang- 2 Crossover-Filter fuumlr jeden Ausgang mit auswaumlhlbarer Neigung 122448dBoct- DRC Multikonfiguration mit hoher Leistungsfaumlhigkeit fuumlr die Konfiguration des
Limitersder Kompression jedes Ein- und Ausgangs- Einstellbare dB-Stufe Polaritaumlt und Verzoumlgerung (delay) fuumlr jeden Ein- und Ausgang- Firmware-Aktualisierung uumlber PC- Graphisches LCD-Display- 32 Voreinstellungen vom Benutzer einstellbar- USB-Schnittstelle fuumlr die Kontrolle und Konfiguration mit dem Computer- Schnittstelle RDnet welche erlaubt bis zu 256 fern liegende Vorrichtungen
zu kontrollieren
PC
PC
RDNET control(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FUNKTIONEN VORDERSEITE
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
BEDIENUNGEN UND FUNKTIONEN
1) DISPLAYDas graphische LCD-Display erlaubt die Informationen des AC26N ohne einen Computer zu benutzen anzuzeigen und zu editieren Der Kontrast kann im Hauptmenuuml eingestellt werden
2) DREHGRIFF Functions Selector UND Push EnterDiese Kontrolle erlaubt sich in den Menuumls auf dem Display zu bewegen und die Parameter auszuwaumlhlen und zu veraumlndernDrehung des Drehgriffes (Functions Selectors)- Man kann sich innerhalb der verschiedenen Menuumlseiten bewegen- Erlaubt die Veraumlnderung der ausgewaumlhlten ParameterDruck des Drehgriffes (Push Enter)- Erlaubt die AuswahlBestaumltigung der Parameter
3) Taste ldquoESCrdquo Diese Kontrolle erlaubt die angezeigten Menuumls zu verlassen oder zur vorherigen Anzeige zuruumlckzukehren
4) Taste ldquoMenuumlrdquo Diese Kontrolle erlaubt den direkten Zugang zum Hauptmenuuml
Deuts
chD
euts
chB
ed
ien
un
gsan
leit
un
gB
ed
ien
un
gsan
leit
un
g
29
Deuts
chD
euts
chB
ed
ien
un
gsan
leit
un
gB
ed
ien
un
gsan
leit
un
g
30
DVA USB Manager
Die Firmware des Verstaumlrkermoduls kann uumlber den USB-Anschluss aktualisiert werdenUm diesen Vorgang zu ermoumlglichen und zu vereinfachen wurde ein dediziertes Programm entwickelt das beim Hersteller angefordert und auf einen Computer installiert werden muss
Wir empfehlen die Software DVA USB Manager direkt von der Webseite dB Technologies (wwwdbtechnologiescom) im Abschnitt laquoSoftware amp Controllerraquo herunterzuladen
DVA Network
AC26N ist mit einer eigenen als RDNET bezeichneten Netzschnittstelle ausgestattet dank der es uumlber ein Interface (RDNET Control) an einen Computer angeschlossen werden koumlnnenHierzu wurde ein Kommunikationsprotokoll entwickelt mit dem die Daten empfangen und gesendet werden Dank dieser Verbindung koumlnnen die Lautsprecherparameter wie Ausgangsleistung Verstaumlrkertemperatur Limiterstatus usw in Echtzeit kontrolliert werden Auszligerdem koumlnnen verschiedene Entzerrungen ausgewaumlhlt bzw neue erstellt werden oder die gewuumlnschte Lautstaumlrke eingestellt werden
Wir empfehlen die Software DVA_Network direkt von der Webseite dB Technologies (wwwdbtechnologiescom) im Abschnitt laquoSoftware amp Controllerraquo herunterzuladenDOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
RUumlCKWANDANSCHLUumlSSE
1586 75 141210 11 13 169 17
14) USB-SteckverbinderDieser USB-Steckverbinder (Typ B) erlaubt den Prozessor an einem Computer anzuschlieszligen um die Firmware mit dem speziellen Programm (DVA Network) zu kontrollieren und zu aktualisieren
15) STROMANSCHLUSS MAINSErlaubt den Anschluss des mitgelieferten Versorgungskabels
16) SICHERUNGSTRAumlGER FUSEAufnahme fuumlr die Netz-Sicherung
17) HAUPTSCHALTER POWERDer Schalter erlaubt das Aus- und Einschalten des Audio-Controllers
BEDIENUNGEN UND FUNKTIONEN
5) WAHLSCHALTER -6dBDer Wahlschalter erlaubt das Level des analogen Eingangs XLR [6] um 6 dB zu verringern und gleichzeitig das hohe Ausgangslevel der Mixer oder anderer Audio-Vorrichtungen auszugleichen Wenn der Balken des Signallevels der Eingaumlnge auf dem Display [1] immer auf Maximum steht zeigt dies an dass das Signallevel am Eingang hoch ist und es wird empfohlen die Daumlmpfung -6dB zu benutzenIm Menuuml Option ist es moumlglich zu kontrollieren ob der Wahlschalter aktiviert ist
6) STECKVERBINDER AM EINGANG A UND BAuf Leitungslinie ausgeglichene EingaumlngeSie koumlnnen auch XLR-Steckdosen aufnehmen
7) AUSGANG-STECKVERBINDER ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo UND ldquo6rdquoAuf Leitungslinie ausgeglichene Ausgaumlnge Sie koumlnnen auch XLR-Stecker aufnehmen
Darauf achten dass die Ausgaumlnge korrekt entsprechend der Einstellungen der einzelnen Kanaumlle an den Lautsprechern oder Verstaumlrkern angeschlossen sind um Schaumlden und Fehlfunktionen vorzubeugen
Abschnitt ldquoAESEBUrdquo
8) EINGANGS-STECKVERBINDER INZusaumltzlich zu den analogen Audio-Eingaumlngen wurde ein digitaler Audio-Eingang SPDIF-AESEBU (AES3) vorgesehen der uumlber das Setup-Menuuml ausgewaumlhlt werden kannDer Eingang erfordert einen ausgeglichenen Anschluss mit einem XLR-Steckverbinder mit einem verdrillten Kabel mit 3 Leitern von 110 Ohm
9) AUSGANGS-STECKVERBINDER OUTDieser Steckverbinder erlaubt das Audiosignal an den analogen oder digitalen Eingaumlngen oder Ausgaumlngen zu verteilen Die Quelle muss uumlber das Menuuml Option eingestellt werdenDer Anschluss muss demselben Standard des Eingang entsprechen [Ref 8]
Abschnitt ldquoRDNETrdquo
10) EINGANGS-STECKVERBINDER DATA INPUTSteckverbinder RJ45 fuumlr den Dateneingang
11) AUSGANGS-STECKVERBINDER DATA LINKSteckverbinder RJ45 fuumlr den Datenausgang Fuumlr die serielle Kaskaden-Verbindung
12) LEUCHTANZEIGE ONDiese gruumlne Anzeige leuchtet nur wenn AC26N uumlber den Computer mit der Haupteinheit RDNET verbunden ist und diese erkannt hat
13) LEUCHTANZEIGE ACTIVEDiese gelbe Anzeige blinkt wenn eine Datenuumlbertragung zwischen RDNET und der Vorrichtung aktiv ist
PUSH
P SHU
SHPU
P SHU
PUSH
ANSCHLUumlSSE
Analoge Audio-AnschluumlsseDie ausgeglichenen Anschluumlsse erlauben die Geraumlusche der Kabel auf ein Minimum zu verringern und so die Benutzung langer Kabel zuzulassenDiese Anschluumlsse koumlnnen sowohl an den Ein- als auch an den Ausgaumlngen benutzt werdenDer XLR-Steckverbinder muss mit Pin 1 an Masse Pin 2 am Pluspol (+) und Pin 3 am Minuspol (-) angeschlossen werden Bei einem abgeschirmten Kabel muss die Abschirmung an Pin 1 liegenDie Verbindungskabel XLR-XLR und XLR-Jack 14 (63 mm) koumlnnen fuumlr den Anschluss
12
3
Eingang
XLR weiblichen
Pin 3 = MinuspolErkaumlltungphase -VE
Pin 3 = MinuspolErkaumlltungphase -VE
1 2
3
Ausgang
XLR maumlnnlichen
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Ring
Schaft
Spitze = PluspolWaumlrmephase +VE
Ring = MinuspolErkaumlltungphase -VE
Schaft=SchirmMasse
Spitze
Die nicht ausgeglichenen Anschluumlsse koumlnnen auch benutzt werden wenn die Kabelgeraumlusche ansteigen und diese Kabel duumlrfen nicht laumlnger sein als 5 MeterDiese Anschluumlsse koumlnnen sowohl an den Ein- als auch an den Ausgaumlngen benutzt werdenDie nicht ausgeglichenen Anschluumlsse koumlnnen das Signallevel am Eingang um 6 dB verringern um dem vorzubeugen muss Pin 3 an Masse angeschlossen werden obwohl dies das Geraumlusch verstaumlrken kann
12
3
Eingang
XLR weiblichen
1 2
3
Ausgang
XLR maumlnnlichen
Spitze Schaft
Spitze = Signal
Schaft=SchirmMasse
Pin 3 = zu Pin 1 gebruumlckt
Pin 3 = zu Pin 1 gebruumlckt
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
31
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
32
Digitales Audio (AESEBU)AESEBU (Protokoll AES3) ist ein ausgeglichener und uumlber einen Transformator elektrisch isolierter Eingang Er erlaubt die Benutzung von zwei Kanaumllen an einem einzigen abgeschirmten bipolaren Kabel Das gedrillte Kabel muss 3-polig sein eine Impedanz von 100 Ohm haben und mit einem XLR-Steckverbinder (AES3 Standard) abgeschirmt sein
RdnetJeder Port RDNet an Control 2 und Control 8 kann an max 32 kompatiblen Vorrichtungen die in Kaskade geschaltet sind angeschlossen werden Im nachstehenden Beispiel ist der Port der Kontrolleinheit RDNET CONTROL 2 am Eingang DATA INPUT eines AC 26N angeschlossen dessen paralleler Ausgang DATA LINK zum Eingang des naumlchsten AC26N geht Im Beispiel ist [n] eine Nummer zwischen 3 und 32 (maximale Anzahl der anschlieszligbaren Vorrichtungen an nur einem Netz)
RJ 45
|1|2|3|4|5|6|7|8|
Die Gesamtlaumlnge des Kabels CAT5 eines Unternetzes kann NICHT laumlnger als 900 Meter sein
Der Steckverbinder muss wie folgt angeschlossen sein1 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio +) 2 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio -)3 ndash Verfuumlgbar fuumlr andere Funktionen (zB analoge Masse)4 ndash digitale Masse5 ndash digitale Masse6 ndash Verfuumlgbar fuumlr andere Funktionen (zB Versorgung)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
EINSCHALTEN
Beim Einschalten der Vorrichtung startet die Initialisierung die einige Sekunden lang dauert Auf dem Display wird das Modell das Logo und der Fortschrittsbalken der Ladung des Programms angezeigt
Nach der Initialisierung erscheint auf dem Display das Menuumlfenster Meters Um die Angaben im Detail zu erfahren beziehen Sie sich bitte auf das Kapitel BESCHREIBUNG DES MENUumlFENSTERS Meters
AC26N kann jetzt benutzt werden
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
MENUrsquo PRINCIPALE
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Die sechs Menuumls im Prozessor zeigen undoder konfigurieren die Systemparameter
Anzeige der Levels der Ein- und Ausgaumlnge Anzeige des benutzten Programms und dessen Status Mute schnell
Speicherung Speicherung und Eliminierung der Systemkonfigurationen
Auswahl der Ausgaumlnge je nach Eingangssignal
Konfiguration jedes einzelnen Kanals
Konfiguration der Schnittfrequenzen und der Filtertypen fuumlr jeden einzelnen Ausgang
Zuordnung der Ein- und Ausgaumlnge Kontrast des Displays Firmware-Version Eingaumlnge und andere Optionen
Das Menuuml und die einzelnen Optionen der Anzeige koumlnnen durch Drehen des Drehgriffes FUNKTIONS SELECTOR ( ) ausgewaumlhlt werden
Die Hauptmenuumls sind
Meters
Preset
Matrix
Ch Job
X-Over
Option
Um die Auswahl zu treffen muss der gewuumlnschte Parameter auswaumlhlt und der Drehgriff Push Enter( | ) gedruumlckt werdenDas selbe Verfahren muss fuumlr die Auswahl undoder die Aumlnderung der Optionen innerhalb der Menuumlpunkte angewendet werden
BESCHREIBUNG DES MENUumlFENSTERS Meters
Diese Seite erlaubt die Konfigurationen und den allgemeinen Status der Ein- und Ausgaumlnge der benutzten Programmversion dessen Status und die Steuerung des Systems anzuzeigen
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
KONFIGURATION UND ANZEIGE
Um in das Fenster des Hauptmenuumls zu gelangen muss die Taste Menuuml ( ) auf der Frontseite der Vorrichtung gedruumlckt werdenMit der Taste ESC ( ) kehrt man von jeder Seite des Menuumls auf die vorherige Seite zuruumlck
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
33
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
34
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziertBei den digitalen Eingangssignalen entspricht die Angabe A und B dem EingangDreht man den Drehgriff FUNCTIONS SELECTOR [2] durchlaumluft man zyklisch die Ein- und Ausgangskanaumlle und die Angabe Mute allgemein (d) der ausgewaumlhlte Kanal wird hervorgehoben
b) BALKEN FUumlR DAS KOMPRESIONSLEVELMUTE KANAL
SIGNALKOMPRESSIONDie Signalkompression wird durch das Gleiten des rechten Balkens von oben nach unten angezeigt
MUTE Jeder einzelne Kanal kann auf Mute gestellt werden Den Kanal auswaumlhlen und den Drehgriff Push Enter [2] druumlcken um die Aumlnderung des Status zu bestaumltigen Die Angabe des Kanals wird durch den Buchstaben M ersetzt und der Balken wird komplett hervorgehobenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werden
c) BALKEN DES SIGNALLEVELSDie Anzeige des Levels jedes einzelnen Kanals wird durch das Gleiten des linken Balkens angezeigt
d) MUTE ALLGEMEINEs ist moumlglich alle Ein- und Ausgaumlnge gleichzeitig auf Mute zu schalten Den Drehgriff FUNCTIONS SELECTOR drehen den Buchstaben M waumlhlen und dann den Drehgriff Push Enter druumlckenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werdenDie allgemeine Stummschaltung hat eine houmlhere Prioritaumlt als die Stummschaltung der einzelnen Kanaumlle
e) ANSTEUERUNGSARTENEs wird angezeigt wie AC26N benutzt wird undoder an welchen Vorrichtungen es angeschlossen ist
= Benutzung stand-alone Kein Anschluss an einer externen Vorrichtung
= Direkt am Netz RDnet und am Computer angeschlossen
= Uumlber USB-Kabel direkt am Computer angeschlossen
f) ANZEIGE DES STATUS DER EINSTELLUNGENHier wird angezeigt ob einer oder mehrere Parameter des geladenen Programms im Vergleich zur letzten Speicherung veraumlndert wurden
Original-Programm
Programm mit veraumlnderten Parametern
g) EINGESTELLTES PROGRAMMDie Nummer zeigt das vom System geladene und benutzte Programm in Bezug auf die Lokalisierung der Speicherung an Fuumlr weitere Details beziehen Sie sich bitte auf das Menuuml Preset
Local
NET
USB
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
BESCHREIBUNG DES MENUumlFENSTERS Ch Job
Dieses Fenster erlaubt die Anzeige der Konfiguration jedes einzelnen Kanals
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) SIGNALLEVELZeigt die Signalstaumlrke an Das Ansteigen der Signalintensitaumlt wird in Dezibel (dB) ausgedruumlckt Der Parameter kann zwischen -8000 dB und +2000 dB in Schritten von 001 dB ausgewaumlhlt werden Ein Anstieg von 6 dB ist fast gleich eine Verdoppelung in linearer Skala des Spannungswertes des SignalsBei einer Staumlrke von 0 dB wird das Signal verstaumlrkt waumlhrend es ein einer Staumlrke von weniger als 0 dB abgeschwaumlcht wird
c) VERZOumlGERUNG DES SIGNALS (DELAY)Das wiedergegebene Audio-Signal kann verzoumlgert werden um die akustische Ausrichtung zu erlauben Dies gleicht die verschiedenen Positionen der Lautsprecher bei der Installation und Klangwiedergabe aus und wird in mS ausgedruumlckt Der Parameter kann zwischen 00 mS und 729 mS in Schritten von 01mS ausgewaumlhlt werden
Um ein Audiosignal auszurichten kann folgende Formel benutzt werden
Verzoumlgerung = GAPx1000)344
Verzoumlgerung = mS (in Millisekunden ausgedruumlckt)GAP = Abstand des Lautsprechers vom Referenzpunkt (in Metern ausgedruumlckt)Klanggeschwindigkeit = 344 ms
d) MUTEJeder einzelne Kanal kann auf Mute gestellt werden Derselbe Befehl kann im Fenster des Menuumls Meters aktiviert werden PS Die al lgemeine Stummschaltung hat eine houmlhere Priori taumlt als die Stummschaltung der einzelnen Kanaumlle
e) PHASEErlaubt die Phasenrotation um 180deg zum EingangssignalDiese Rotation erlaubt vor Allem die Optimierung der niederen Frequenzen bei komplexen Installationen
f) ENTZERRUNGENDieser Befehl oumlffnet das Menuumlfenster fuumlr die Entzerrung des einzelnen Kanals Er wird vor Allem benutzt um eine oder mehrere Frequenzen zu korrigieren die gedaumlmpft oder verstaumlrkt werden muumlssen
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
35
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
36
AC26N verwaltet 12 Filter fuumlr jeden einzelnen Ein- und Ausgangskanal mit drei verschiedenen Konfigurationen- Equalizer PEQ (peaking equalizer) ist ideal um nur ein bestimmtes Frequenzband
zu identifizieren zu isolieren und zu korrigieren Es gehen alle Frequenzen durch aber nur die um die mittlere Frequenz steigt und sinkt um eine bestimmte Bandbreite und eine bestimmte Staumlrke
- Equalizer High-Shelf geht alle Frequenzen durch aber die Frequenzen uumlber der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
- Equalizer Low-Shelf geht alle Frequenzen durch aber die Frequenzen unter der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
f Nummerierung der 12 verfuumlgbaren Filter fuumlr diesen Ein- oder Ausgang1
f2 Es wird der Filtertyp angezeigt
Dis Ausgeschaltet (nicht vorhanden)
PEQ Peaking equalizer
Sh H Filter High-Shelf
Sh L Filter Low-shelf
Beispiele PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
ANMERKUNGDer Parameter Bw legt das Frequenzfeld neben der eingestellten Frequenz fest wo der Filter aktiviert wird je houmlher der Bw-Wert desto houmlher das Frequenzfeld (1Bw=1 Oktave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filter High-Shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filter Low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) KOMPRESSIONDieser Befehl oumlffnet das Menuumlfenster fuumlr die Kompression des einzelnen Kanals
g1) TresholdIdentifiziert die Schwelle an der das Kompressionsverhaumlltnis beginnt Der Basiswert 11
g2) RatioIdentifiziert das Kompressionsverhaumlltnis zwischen dem Ein- und Ausgangssignal
g3) Post Gain Attach Release HoldDiese Daten entsprechen dem Kompressionsverhaumlltnis das man erreichen moumlchte
Post Gain ist der Gewinn am AusgangAttack ist die Anschlusszeit Release ist die ReleasezeitHold ist die Beibehaltungszeit
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
BESCHREIBUNG DES MENUumlFENSTERS Preset
Dieses Fenster erlaubt bis zu 32 Konfigurationen im AC26N zu speichernDer Hersteller liefert das System mit einem voreingestellten Programm das auf Position 0 gespeichert ist und nicht uumlberschrieben werden kann
032 Es zeigt die Lokalisierung der Speicherung der KonfigurationDiese Nummer erscheint auch im Fenster Meters auf der Position (g) Das benutzte Programm kann jederzeit vom Benutzer angezeigt werden
Empty Preset Es ist der Name der der Nummer der Lokalisierung zugeordnet wird wenn keine Einstellung gespeichert ist (leer)
Local preset Es i s t de r Name de r de r Nummer de r Loka l i s i e rung zugeordnet wird wenn eine Konfiguration gespeichert wird
ANMERKUNG = Man kann eine Einstellung mit dem gewuumlnschten Namen mit max 16 Buchstaben nur speichern wenn man die Schnittstelle uumlber den Computer benutzt
Bei der Wahl eines Programms erscheint folgendes Fenster
Anzeige des Namens der dem Programm zugeordnet istUm auf die Anwendung einzuwirken stehen 3 Auswahlmoumlglichkeiten zur Verfuumlgung
Das Programm wird im Speicher des AC 26N gespeichert
Das Programm wird geloumlscht
Das Programm wird geladen und ist bereit fuumlr die Benutzung
Save
Del
Load
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
37
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
38
BESCHREIBUNG DES MENUumlFENSTERS X-Over
Dieses Fenster erlaubt fuumlr jeden Ausgang einen Bassdurchgangsfilter einen Hochdurchgangsfilter oder mittels Kombination von beiden einen Banduumlbergangsfilter zu waumlhlenDer Filter ist ein Linkwitz-Riley wo man die Neigung von 12 dBoct 24dBoct oder 48 dBoct und die entsprechende Schnittfrequenz auswaumlhlen kann
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) AUSGANGSKANAumlLE
Die Steckverbinder am Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) FILTER CROSSOVERDen Filter nach Bedarf waumlhlen Man kann folgendes auswaumlhlen
Dis Kein Filter aktiviert
HP Hochdurchgangsfilter nur den Teil des Audiosignals durchlassen der uumlber der Schnittfrequenz liegt
LP Bassdurchgangsfilter nur den Teil des Audiosignals durchlassen der unter der Schnittfrequenz liegt
Filter-Konfiguration Tiefpass Hochpass
Nichts Dis Dis
Hochpass HP Dis
Tiefpass Dis LP
Bandpass HP LP
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
c) DAumlMPFUNGSNEIGUNGDie Daumlmpfungsneigung des Audiosignals auf der Basis der Verringerung auswaumlhlen die man erreichen moumlchte Je houmlher die Daumlmpfungsneigung bei gleicher Schnittfrequenz desto groumlszliger ist die Signalauswahl Man kann folgendes waumlhlen
12 entsprechend 12 dboct
24 entsprechend 24 dboct
48 entsprechend 48 dboct
d) SCHNITTFREQUENZErlaubt die Durchgangsfrequenz der niederen Frequenzen (Bassdurchgangsfilter) oder der hohen Frequenzen (Hochdruchgangsfilter) einzustellenDie Auswahl des Schnitts bezieht sich auf die Wiedergabe die man erreichen moumlchteDie benutzte Maszligeinheit ist Hz
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
BESCHREIBUNG DES MENUumlFENSTERS Matrix
Erlaubt fuumlr jeden Ausgang das Eingangssignal zu waumlhlen das als Quelle benutzt werden soll
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) AUSGANGSKANAumlLEIdentifizierung des einzustellenden Ausgangskanals
b) IDENTIFIZIERUNG DER EINGAumlNGEDen Signaltyp auswaumlhlen der nach eigener Anforderung jedem einzelnen Ausgang zugeordnet werden soll Man kann folgendes waumlhlen
In A Das Signal wird dem Eingang A zugeordnet
In B Das Signal wird dem Eingang B zugeordnet
In A+B Zuordnung der a lgebra ischen Summe der be iden Eingangssignale A und B
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
BESCHREIBUNG DES MENUumlFENSTERS Option
Erlaubt die Anzeige der Systemeinstellungen wie die Zuordnung der Ein- und Ausgaumlnge Daumlmpfung Displaykontrast und Firmware-Version
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B Src
Diese Option erlaubt die Einstellung des Audio-Signaltyps am Eingang
Analoge Audiosignale (Eingaumlnge A und B)
Digitale Audiosignale (Eingang AESEBU)
DigOut Src
An In =Audiosignale an den analogen Eingaumlngen
Dig In =Audiosignale am digitalen Eingang
OUT 1-2 =Audiosignale an den Ausgaumlngen 1 und 2
OUT 3-4 =Audiosignale an den Ausgaumlngen 3 und 4
OUT 5-6 =Audiosignale an den Ausgaumlngen 5 und 6
Input Mode
An In
Dig In
Indip =
Linked =
Diese Option erlaubt die Audioquelle zu waumlhlen die fuumlr den Steckverbinder AESEBU OUT (digitaler Ausgang) bestimmt ist
Erlaubt die Eingaumlnge zu konfigurieren
Sie sind unabhaumlngig und selbststaumlndig sie unterliegen keinen Verpflichtungen untereinander Sie sind verbunden und funktionieren im Stereo-Modus
Die Kompressoren Filter Verzoumlgerungen die Lautstaumlrke sind bei beiden Kanaumllen identisch
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
39
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
40
Atten PadZeigt an wie der Wahlschalter -6 dB auf der Ruumlckseite eingestellt ist [Ref 5] Dieser Wahlschalter muss aktiviert werden wenn das Level an den analogen Eingaumlngen zu hoch ist Der Wahlschalter wird uumlber die Taste aktiviert im Menuuml gibt es nur eine Anzeige
0dB = Wahlschalter nicht aktiviert
-6dB = Wahlschalter aktiviert
Contrast
10 heller 60 dunkler 100
Fw Vers
Die Eingangssignale sind dieselben wie die Eingangsquelle
Die Eingangssignale werden vom internen Prozessor um -6 dB gedaumlmpft
Erlaubt den Kontrast des LCD-Displays einzustellen um den Unterschied der Helligkeit auf den Installationsort auszurichten Ein deutlicheres Display erlaubt auf korrekte und schnelle Weise innerhalb der Menuumls zu surfenDie Hersteller-Einstellung am Ausgang liegt bei 60
Zeigt die Firmware-Version des Prozessors an
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
41
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
42
TECHNISCHE DATEN
Antwort in FrequenzDynamische GammaCMMRCrosstalkDistorsion
ProzessorFrequenz der DatenausarbeitungAnaloge Converter Verzoumlgerung der VerteilungSpeicherung der Konfigurationen
DisplayTastenBedienungen
Analoger Eingang ndeg2 x XLR (3-poliger Female Stecker)Impedanz des Eingangs gt10KOhmMaximales Level +21dBu ohne PAD
+27dBu bei PAD
Impedanz des Ausgangs 50OhmMaximales Level +21dBu Typ symmetrisch
Typ SPDIF-AESEBU (AES3)
Typ Entsprechend dem Standard des Eingang
Typ
Typ
NETZSPANNUNGABMESSUNGEN (BXHXT)GEWICHT
AUDIO-LEISTUNGEN+- 01dB (20 to 30kHz)116dB typgt 60dB (50 to 10kHz)lt -100dB0002 (1kHz +4dBu)
DIGITALE AUDIO-LEISTUNGEN DSP 2856-bit 48KHz24-bit BURR BROWN15ms32 preset
KONTROLLEN LCD GrafikESC - MENU - FUNCTIONS SELECTIONENTER
EIN-AUSGAumlNGE
Analoger Ausgang ndeg6 x XLR (3-poliger Male Stecker)
Digitaler Eingang ndeg1x XLR (3-poliger female Stecker)
Digitaler Ausgang ndeg1x XLR (3-poliger Male Stecker)
Ein-Ausgang Rdnet ndeg2 x XLR RJ45 (kabel CAT 5) USB Typ B
KONTROLLPARAMETER AUDIOStaumlrke -80dB a +20dB step 01dBVerzoumlgerung Eingang 0 a 729mS step 01 mS
Ausgang 0 a 340mS step 01mSPhasenrotation 0deg - 180deg
KOMPRESSIONSchwelle -80dB a +20dB step 01dBVerhaumlltnis 11 a Inf1 step 001Staumlrke am Ausgang 0dB a 40dB step 01dBAnschlusszeit 1mS a 1000mS step 01mSReleasezeit 1mS a 1000mS step 01mSBeibehaltungszeit 1mS a 1000mS step 01mS
EQUALIZER12 Equalizer fuumlr jeden Ein- und Ausgang
PEQ (parametrischer) Hi-shelf Lo-sheftFrequenz 20Hz a 20KHz step 1HzStaumlrke -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (lediglich PEQ)
FILTER CROSSOVERFilter Linkwitz Riley
HP HochdurchgangsfilterLP Bassdurchgangsfilter
Neigung 12dBoct - 24dBoct - 48dBoctSchnittfrequenz 5Hz a 20KHz step 1Hz
Full-range 100-240Vac 50-60Hz430482x43x130mm 19Kg
AnmerkungenSpezifikationen unterliegen Aumlnderungen ohne Vorankuumlndigung
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
INTRODUCTIONAC26N est un processeur audio numeacuterique pour la gestion de leacutequipement audio conccedilu pour des installations fixes et mobiles Il fonctionne selon une technologie de pointe avec des processeurs agrave 2856bits et des convertisseurs ADDA agrave 24-bits hautes performances Les fonctions du processeur sont les niveaux dentreacutee et de sortie le deacutelai (delay) la polariteacute 12 bandes deacutegalisation par canal dentreacutee et de sortie diffeacuterentes seacutelections de croisement (crossover) et un limiteur hautes performances Le controcircle des filtres a une reacutesolution de 1Hz Les entreacutees et les sorties peuvent ecirctre programmeacutees en plusieurs configurations pour satisfaire tous les besoins AC26N peut ecirctre controcircleacute en temps reacuteel et tous les paramegravetres peuvent ecirctre configureacutes depuis le pupitre frontale et par ordinateur avec interface graphique intuitive accessible via le logiciel laquoDVA Networkraquo et une connexion de reacuteseau deacutedieacutee RDnet ou USBLa mise agrave jour du logiciel pour lUniteacute centrale et DSP par ordinateur portable permet de maintenir le dispositif actualiseacute Il est possible denregistrer et de rappeler 32 configurations preacute-eacutequipeacutees de configuration
Contenu de lemballage - AC26N - Mode demploi- CD logiciel- Cacircble dalimentation
Caracteacuteristiques- 2 entreacutees et 6 sorties avec adressage flexible- Entreacutee et sortie steacutereacuteo AESEBU adressables - DSP 2856-bit- Convertisseurs AD BURR BWOWN 24-bit hautes performances- Freacutequence de reacutesolution des filtres 1 Hz - 12 eacutegaliseurs parameacutetriques pour chaque entreacutee et sortie- 2 filtres de croisement par sortie avec pente seacutelectionnable agrave 122448dBoct- DRC agrave configuration multiple hautes performances pour configuration limiteur
compression pour chaque entreacutee et sortie- Niveau reacuteglable en dB polariteacute et deacutelai pour chaque entreacutee et sortie- Mise agrave jour du micrologiciel par lordinateur- Affichage graphique agrave cristaux liquides- 32 preacutereacuteglages enregistrables par lutilisateur- Interface USB pour le controcircle et la configuration par ordinateur- Interface RDnet permettant de controcircler jusquagrave 256 dispositifs agrave distance
PC
PC
RDNETcontrol(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FONCTIONS DE LA FACE AVANT
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
COMMANDES ET FONCTIONS1) AFFICHAGE
Laffichage graphique agrave cristaux liquides permet de visualiser et deacutediter les informations de lAC26N sans utiliser lordinateur Le contraste peut ecirctre configureacute dans le menu principal
2) MANETTE Functions Selector et Push EnterCe controcircle permet de se deacuteplacer de seacutelectionner et de modifier les paramegravetres dans les menus affichables agrave leacutecranRotation de la manette (Functions Selectors)- permet de se deacuteplacer sur les diffeacuterentes pages du menu - permet de modifier les paramegravetres seacutelectionneacutesPression de la manette (Push Enter)- permet de seacutelectionnervalider les paramegravetres
3) Bouton ESC Ce controcircle permet de quitter les menus afficheacutes ou de revenir agrave la visualisation preacuteceacutedente
4) Bouton Menu Ce controcircle permet dacceacuteder directement au menu principal
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
Fra
nccedilais
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
43
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
Fra
nccedilais
44
DVA Network
AC26N est eacutequipeacute dune interface de reacuteseau proprieacutetaire deacutenommeacutee RDNET au moyen de laquelle il est possible de sinterfacer agrave lordinateur agrave travers un peacuteripheacuterique (RDNET control)
Pour cela un protocole de communication a eacuteteacute deacuteveloppeacute avec lequel il est possible de recevoir et denvoyer les donneacutees ce branchement permet de faire le monitorage en temps reacuteel des paramegravetres du diffuseur comme puissance de sortie tempeacuterature de lamplificateur eacutetat du limiteur etc Il est aussi possible de seacutelectionner diffeacuterentes eacutegalisations ou den creacuteer de nouvelles et de reacutegler les niveaux de volume souhaiteacutes au moyen dun plug-in approprieacute
On conseille de teacuteleacutecharger gratuitement le logiciel DVA Network directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
DVA USB Manager
On conseille de teacuteleacutecharger gratuitement le logiciel DVA USB Manager directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
Le micrologiciel du module amplificateur peut ecirctre remis agrave jour par le port USBPour rendre cette mise agrave jour possible et facile un programme speacutecifique a eacuteteacute deacuteveloppeacute
DOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
CONNEXIONS DU PANNEAU ARRIEgraveRE
1586 75 141210 11 13 169 17
14) Connecteur ldquo USBrdquoCe connecteur USB (type B) permet de connecter le processeur agrave un ordinateur pour le controcircle et la mise agrave jour du micrologiciel via un programme deacutedieacute (DVA Network)
15) PRISE DALIMENTATION MAINSPermet la connexion du cacircble dalimentation fourni de seacuterie
16) PORTE-FUSIBLE FUSELogement pour fusible de ligne
17) INTERRUPTEUR GENERAL POWERLinterrupteur permet de mettre en marche ou deacuteteindre le controcircleur audio
COMMANDES ET FONCTIONS
5) SELECTEUR ldquo-6dBrdquoLe seacutelecteur permet de reacuteduire de 6dB les niveaux dentreacutee analogiques XLR [6] tout en compensant les niveaux eacuteleveacutes de sortie des meacutelangeurs ou dautres dispositifs audio Quand la barre du niveau de signal des entreacutees sur laffichage [1] reste au maximum cela indique que le niveau du signal entrant est eacuteleveacute Il est alors conseilleacute dutiliser latteacutenuation -6dBIl est possible de veacuterifier quand le seacutelecteur est activeacute par le menu Option
6) CONNECTEURS DENTREE ldquoArdquo ET ldquoBrdquoEntreacutees eacutequilibreacutees au niveau de la ligneIls sont en mesure daccepter des connecteurs XLR macircles
7) CONNECTEURS DE SORTIE ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo ET ldquo6rdquoSorties eacutequilibreacutees au niveau de la ligne Ils sont en mesure daccepter des connecteurs XLR femelles
Prendre garde agrave brancher convenablement les sorties sur les diffuseurs ou les amplificateurs en fonction des configurations de chaque canal pour eacuteviter des deacutegacircts et des problegravemes de fonctionnement
Section ldquoAESEBUrdquo
8) CONNECTEUR DENTREE INOutre les entreacutees audio analogiques une entreacutee audio numeacuterique SPDIF-AESEBU (AES3) a eacuteteacute preacutevue et peut ecirctre seacutelectionneacutee par le menu de setupLentreacutee requiert une connexion eacutequilibreacutee en utilisant un connecteur XLR avec un cacircble agrave 3 conducteurs de 110ohm torsadeacute
9) CONNECTEUR DE SORTIE OUTCe connecteur permet de relancer le signal audio dans les entreacutees analogiques ou numeacuteriques ou sur les sorties La source doit ecirctre reacutegleacutee par le menu OptionLa connexion sera conforme agrave la mecircme norme que lentreacutee [reacutef8]
Section ldquoRDNETrdquo
10) CONNECTEUR DENTREE DATA INPUTConnecteur RJ45 entreacutee de donneacutees
11) CONNECTEUR DE SORTIE DATA LINKConnecteur RJ45 sortie de donneacutees pour la connexion de seacuterie en cascade
12) VOYANT LUMINEUX ONCe voyant de couleur verte sallume uniquement quand lAC26N a reconnu et est connecteacute agrave luniteacute principale RDNET par lordinateur
13) VOYANT LUMINEUX ACTIVECe voyant de couleur jaune clignote quand une transmission des donneacutees est active entre RDNET et le dispositif
PUSH
P SHU
SHPU
P SHU
PUSH
CONNEXIONS
Audio analogiquesLes connexions eacutequilibreacutees permettent de reacuteduire au minimum le bruit provoqueacute par les cacircbles et dutiliser de longs cacircblesCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLe connecteur XLR doit ecirctre brancheacute avec la broche 1 agrave la masse la broche 2 au chaud (+) et la broche 3 au froid (-) En cas de cacircble blindeacute brancher le blindage agrave la broche 1Les cacircbles de connexion XLR-XLR et XLR-Jack14(63mm) peuvent semployer pour la connexion agrave lAC26N
12
3
Entreacutee
Entreacutee
XLR - femme
XLR - femme
1 2
3
Sortie
Sortie
XLR - Macircle
XLR - Macircle
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2 = Point chaudPhase +VE
Broche 3 =Point froidPhase -VE
Broche 3 =Point froidPhase -VE
Anneau
Manchon
Pointe Point chaudPhase +VE
Anneau = Point froidPhase -VE
ManchonB Masselindeacute
Pointe
Les connexions deacuteseacutequilibreacutees peuvent semployer mecircme si le bruit provoqueacute par les cacircbles augmente Les cacircbles ne peuvent deacutepasser 5m de longCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLes connexions deacuteseacutequilibreacutees peuvent abaisser le niveau du signal entrant de 6dB Pour remeacutedier agrave cet inconveacutenient il faut brancher la broche 3 agrave la masse mecircme si cela augmente le bruit
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
45
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
46
12
3
1 2
3
Pointe Manchon
Pointe = Signal
Broche 3 = Link to Pin 1
Broche 3 = Link to Pin 1
ManchonB Masselindeacute
Audio numeacuteriques (AESEBU)
AESEBU (protocole AES3) est une entreacutee eacutequilibreacutee isoleacutee eacutelectriquement agrave laide dun transformateur Elle permet demployer deux canaux audio dans un seul cacircble bipolaire blindeacute Les caracteacuteristiques du cacircble doivent ecirctre de 3 pocircles impeacutedance 100ohm torsadeacute et blindeacute avec connecteur XLR (AES3 standard)
RJ 45
|1|2|3|4|5|6|7|8|
RDnet
Chaque port RDNet des Control 2 et Control 8 peut ecirctre brancheacute agrave un maximum de 32 dispositifs compatibles placeacutes en cascade Dans lexemple suivant le port de luniteacute de controcircle RDNET CONTROL 2 est relieacute agrave lentreacutee DATA INPUT dun AC26N dont la sortie parallegravele DATA LINK est envoyeacutee agrave lentreacutee de lAC26N successif Dans lexemple [n] est un nombre compris entre 3 et 32 (limite maximale des dispositifs que lon peut relier agrave un sous-reacuteseau)
La longueur totale du cacircble CAT5 dun sous-reacuteseau NE peut PAS deacutepasser 900 megravetres
Le connecteur doit ecirctre relieacute comme 1 ndash disponible pour dautres fonctions (par exemple audio +) 2 ndash disponible pour dautres fonctions (par exemple audio )3 ndash disponible pour dautres fonctions (par exemple masse analogique)4 ndash masse numeacuterique5 ndash masse numeacuterique6 ndash disponible pour dautres fonctions (par exemple alimentation)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
MISE EN MARCHE
Lors de la mise en marche du dispositif linitialisation deacutebute et dure quelques secondes Leacutecran affiche le modegravele le logo et la barre de progression du chargement du programme
En fin de processus dinstallation leacutecran affiche la fenecirctre du menu Meters Pour connaicirctre les indications en deacutetail consulter le paragraphe DESCRIPTION FENETRE MENU Meters
LAC26N est precirct agrave lemploi
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION ET VISUALISATION
Pour entrer dans la fenecirctre du menu principal il faut pousser sur la touche MENU ( ) agrave lavant du dispositifDune page quelconque du menu en poussant sur la touche ESCrdquo ( ) on revient automatiquement sur la page-eacutecran preacuteceacutedente
MENU PRINCIPAL
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Le processeur contient six menus Ils montrent etou configurent les paramegravetres du systegravemeLes menus principaux sont
Meters Visualisation des niveaux des entreacutees et des sorties visualisation du programme utiliseacute et eacutetat mute rapide
Preset Meacutemoriser enregistrer et eacuteliminer les configurations du systegraveme
Matrix seacutelectionner les sorties en fonction du signal entrant
Ch Job configuration de chaque signal
X-Over configurer les freacutequences de coupure et les types de filtres pour chaque sortie
Option attribution des entreacutees et des sorties contraste daffichage la version du micrologiciel les entreacutees et dautres options
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
47
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
48
DESCRIPTION DE LA FENETRE MENU Metersrdquo
Cette fenecirctre permet de visualiser les configurations et leacutetat geacuteneacuteral des entreacutees et des sorties la version du programme utiliseacute son eacutetat et le mode de pilotage du systegraveme
Les menus et les options afficheacutees peuvent se seacutelectionner en tournant la manette ldquoFUNCTIONS SETECTORrdquo ( ) Pour avoir accegraves agrave linteacuterieur de la seacutelection il faut mettre le paramegravetre souhaiteacute en eacutevidence et pousser sur la manette ldquoPush Enterrdquo ( | ) Il faut en faire de mecircme pour seacutelectionner etou modifier les options dans les commandes du menu
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositifAvec des signaux dentreacutee numeacuteriques les indications ldquoArdquo et ldquoBrdquo correspondent agrave lentreacuteeEn tournant la manette ldquoFUNCTIONS SELECTORrdquo [2] on fait deacutefiler en mode cyclique les canaux dentreacutee de sortie et lindication de mute geacuteneacuteral (d) le canal seacutelectionneacute est mis en eacutevidence
b) BARRE DE NIVEAU DE COMPRESSIONMUTE CANAL
COMPRESSION DE SIGNALLa compression du signal est visualiseacutee par le deacutefilement de la barre de droite de haut en bas
MUTE Chaque canal peut ecirctre placeacute en mute Seacutelectionner le canal et pousser sur la manette ldquoPush Enterrdquo [2] pour valider le changement deacutetat Lindication du canal sera remplaceacutee par la lettre M et la barre sera totalement mise en eacutevidencePour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterations
c) BARRE DE NIVEAU DE SIGNALLindication du niveau de chaque canal est signaleacutee par le deacutefilement de la barre de gauche
d) MUTE GENERALIl est possible de mettre simultaneacutement toutes les entreacutees et les sorties en mute Tourner la manette ldquoFUNCTIONS SELECTORrdquo seacutelectionner la lettre M et pousser sur la manette Push EnterPour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterationsLe mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) MODES DE COMMANDEIl affiche le mode dutilisation etou les dispositifs qui sont relieacutes agrave lAC26N
Local = utilisation autonome Aucune connexion agrave un dispositif exteacuterieur
NET = relieacute directement au reacuteseau deacutedieacute RDNet et agrave lordinateur
USB = relieacute directement agrave un ordinateur par cacircble USB
f) INDICATION DETAT DE PARAMETRAGECette indication permet de constater si un ou plusieurs paramegravetre(s) du programme chargeacute aont eacuteteacute modifieacute(s) par rapport au dernier sauvetage
= programme dorigine
= programme avec des paramegravetres modifieacutes
g) PROGRAMME CONFIGURELe chiffre indique le programme chargeacute et utiliseacute par le systegraveme agrave lemplacement de sauvetage Consulter le menu de Preset pour de plus amples deacutetails
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
DESCRIPTION DE LA FENETRE MENU Ch Job
Cette fenecirctre permet dafficher la configuration de chaque canal
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) NIVEAU DU SIGNALIndique le gain du signal Laugmentation de lintensiteacute dun signal est libelleacutee en deacutecibel (dB) Le paramegravetre peut ecirctre seacutelectionneacute de -8000dB agrave +2000dB avec des pas de 001dB Une augmentation de 6dB est eacutegale approximativement au redoublement agrave leacutechelle lineacuteaire du niveau du signal sous tensionAvec un gain supeacuterieur agrave 0dB le signal est amplifieacute tandis quavec un gain infeacuterieur agrave 0dB le signal est atteacutenueacute
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
49
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
50
c) DELAI DU SIGNAL (DELAY)Le signal audio reproduit peut ecirctre retardeacute pour permettre lalignement acoustique Cela compense les diffeacuterentes positions des diffuseurs pendant linstallation et la reproduction sonore Il se libelle en mS Le paramegravetre peut ecirctre seacutelectionneacute de 00mS agrave 729mS avec un pas de 01mSPour aligner un signal audio il est possible dutiliser la formule suivante
Deacutelai = (GAPx1000)344
Deacutelai = ms (en millisecondes)GAP = distance du diffuseur du point de reacutefeacuterence (en megravetres)Vitesse du son = 344ms
d) MUTEChaque canal peut ecirctre placeacute en mute La mecircme commande peut ecirctre activeacutee dans la fenecirctre du menu meters NB Le mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) PhasePermet la rotation de phase de 180deg par rapport au signal entrantCette rotation permet loptimisation surtout des basses freacutequences dans les installations complexes
f) EGALISATIONCette commande ouvre la fenecirctre du menu deacutegalisation de chaque canal Elle sert surtout pour corriger une ou plusieurs freacutequences qui doivent ecirctre atteacutenueacutees ou augmenteacutees
M M
LAC26N gegravere 12 filtres par canal dentreacutee et sortie avec trois types de configurations diffeacuterentes - Leacutegaliseur PEQ (peaking equalizer) est ideacuteal pour identifier isoler et
corriger une seule plage de freacutequences bien deacutetermineacutee Toutes les freacutequences passent mais il augmente ou diminue uniquement celles autour de la freacutequence centrale pour une bande preacutecise et un gain deacutefini
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessus de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessous de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
f Numeacuterotation des 12 filtres disponibles pour cette entreacutee ou cette sortie1
f Le type de filtre est afficheacute 2
Dis Deacutesactiveacute (absent)
PEQ Peaking equlizer
Sh H Filtre high-shelf
Sh L Filtre high-shelf
Exemples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
REMARQUELe paramegravetre Bw deacutetermine le champ de freacutequences adjacent agrave la freacutequence configureacutee ougrave est activeacute le filtre Plus la valeur Bw est eacuteleveacutee plus vaste est le champ de freacutequences (1Bw=1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONCette commande ouvre la fenecirctre du menu de compression de chaque canal
g1) TresholdIdentifie le seuil ougrave commence le rapport de compression La valeur de base 11
g2) RatioIndique le rapport de conversion entre le signal entrant et le signal sortant
g3) Post Gain Attach Release HoldCes donneacutees deacutependent du rapport de conversion que lon veut obtenir - Post Gain est le gain de sortie- Attack est le temps dattaque - Release est le temps de relacircchement- Hold est le temps de maintien
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
52
DESCRIPTION DE LA FENETRE MENU Preset
Cette fenecirctre permet de meacutemoriser jusquagrave 32 configurations dans lAC26NLe fabricant fournit le systegraveme avec un programme configureacute et enregistreacute en position 0 et non susceptible deacutecrasement
032 Elle indique lemplacement de sauvetage de la configurationCe numeacutero apparaicirct dans la fenecirctre Meters en position (g) A tout moment le programme utiliseacute peut ecirctre afficheacute par lutilisateur
Empty Preset Cest le nom qui est associeacute au numeacutero de lemplacement quand aucune configuration (vide) nest enregistreacutee
Local preset Local preset est le nom qui est associeacute au numeacutero de lemplacement quand on enregistre une configuration NB = Il est possible denregistrer une configuration avec lenom souhaiteacute de 16 lettres tout au plus agrave condition que lonutilise linterface via lordinateur
Le nom du programme assigneacute est indiqueacutePour toucher agrave lapplication 3 choix soffrent agrave vous
Save Le programme est enregistreacute en meacutemoire de lAC26N
Del Le programme est effaceacute
Load Le programme est chargeacute et precirct agrave lemploi
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
51
DESCRIPTION DE LA FENETRE MENU X-Over
Cette fenecirctre permet de seacutelectionner un filtre passe bas un filtre passe haut ou par la combinaison des deux de creacuteer un filtre passe bande pour chaque sortieLe filtre actif est un Linkwitz-Riley qui permet de seacutelectionner la pente de 12dBoct 24dBoct ou 48dBoct et sa freacutequence de coupure
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) CANAUX DE SORTIE
Les connecteurs de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) FILTRE CROSSOVERSeacutelectionner le filtre selon les besoins Il est possible de seacutelectionner
Dis Aucun filtre activeacute
HP Filtre passe-haut laisse passer uniquement la partie de signal audio supeacuterieure agrave la freacutequence de coupure
LP Filtre passe-bas laisse passer uniquement la partie de signal audio infeacuterieure agrave la freacutequence de coupure
Configuration du filtre Passe-haut Passe-bas
Rien Dis Dis
Passe-haut HP Dis
Passe-bas Dis LP
Passe-bande HP LP
12dBoct
24dBoct
Hz
dB
Ga
in 48dBoct
12dBoct
24dBoct
Hz
dB
Ga
in
48dBoct
c) PENTE DATTENUATIONSeacutelectionner la pente datteacutenuation du signal audio en fonction de la diminution que lon veut obtenir Plus la pente datteacutenuation est eacuteleveacutee agrave eacutegaliteacute de freacutequence de coupure plus eacuteleveacutee sera la seacutelection du signal Il est possible de seacutelectionner
12 correspond agrave 12dboct
24 correspond agrave 24dboct
48 correspond agrave 48dboct
d) FREQUENCE DE COUPUREElle permet de reacutegler la freacutequence de passage des freacutequences infeacuterieures (filtre passe-bas) ou des freacutequences supeacuterieures (filtre passe-haut) uniquementLe choix de la coupure deacutepend de la reproduction que lon veut obtenirLuniteacute de mesure utiliseacutee est lHz
Hz
Hz
dB
dB
Ga
in
f0
f0
0dB0dB
0dB
-6dB
freacutequence
freacutequence
freacutequence
freacutequence
Ga
in
f0
0dB
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
53
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
54
DESCRIPTION DE LA FENETRE MENU Matrix
Elle permet de seacutelectionner le signal entrant agrave utiliser comme source pour chaque sortie
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) CANAUX DE SORTIEIdentification du canal sortant agrave reacutegler
b) IDENTIFICATIONS DES ENTREESSeacutelectionner le type de signal agrave associer agrave chaque sortie en fonction des besoins Il est possible de seacutelectionner
In A Le signal entrant A est associeacute
In B Le signal entrant B est associeacute
In A+B La somme algeacutebrique des deux signaux entrants A et B est associeacutee
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
DESCRIPTION DE LA FENETRE MENU Option
Permet dafficher les reacuteglages du systegraveme comme lassignation des entreacutees et des sorties latteacutenuation le contraste de laffichage et la version du logiciel
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcCette option permet de reacutegler le type de signal audio entrant
An In =signaux audio analogiques (entreacutees ldquoArdquo et ldquoBrdquo)
Dig In =signaux audio numeacuteriques (entreacutee AESEBU)
DigOut SrcCette option permet de seacutelectionner la source audio qui sera adresseacutee sur le connecteur AESEBU OUT (sortie numeacuterique)
An In = signaux audio des entreacutees analogiques
Dig In =signaux audio sur lentreacutee numeacuterique
OUT 1-2 = signaux audio sur les sorties 1 et 2
OUT 3-4 = signaux audio sur les sorties 3 et 4
OUT 5-6 = signaux audio sur les sorties 5 et 6
Input ModePermet de configurer les entreacutees
Indip = sont indeacutependantes et autonomes Ne sont soumises agrave aucun type de lien
Linked = sont unies et fonctionnent en mode steacutereacuteo Les compresseurs les filtres les deacutelais le volume sont identiques pour les deux canaux
Atten PadIndique le mode de reacuteglage du seacutelecteur ldquo-6dBrdquo placeacute agrave larriegravere [reacutef 5] Il faut activer ce seacutelecteur quand les niveaux dentreacutee analogiques sont trop eacuteleveacutes Le seacutelecteur sactive uniquement par le bouton Dans le menu il sagit dune simple visualisation
0dB = seacutelecteur non activeacute Les signaux dentreacutee sont identiques agrave la source entrante
-6dB = seacutelecteur activeacute Les signaux entrants sont atteacutenueacutes de -6dB par le processeur interne
ContrastIl permet de reacutegler le contraste de laffichage agrave cristaux liquides pour compenser la diffeacuterence de luminositeacute avec le lieu dinstallation Une plus grande clarteacute de laffichage permet de naviguer convenablement et rapidement dans les menusLe reacuteglage agrave la sortie de lusine du fabricant est de 60
10 plus clair 60 plus fonceacute 100
Fw VersIndique la version du logiciel du processeur
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
55
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
56
DONNES TECHINIQUES
PERFORMANCES AUDIOReacuteponse en freacutequence +- 01dB (20 to 30kHz)Plage dynamique 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsion 0002 (1kHz +4dBu)
PERFORMANCES AUDIO NUMERIQUES Processeur DSP 2856-bit Freacutequence de traitement des donneacutees 48KHzConvertisseurs analogiques 24-bit BURR BROWNDeacutelai de propagation 15msMeacutemorisations des configurations 32 preset
CONTROLES Affichage LCD graficoBoutonsCommandes ESC - MENU - FUNCTIONS SELECTION
ENTERENTREESSORTIESEntreacutee analogique ndeg2 x XLR (3 broches femelle)
Impeacutedance dentreacutee gt10KOhmNiveau maximum +21dBu senza PAD
+27dBu con PADSortie analogique ndeg6 x XLR (3 broches macircle )
Impeacutedance de sortie 50OhmNiveau maximum +21dBuType Balanceacute
Entreacutee numeacuterique ndeg1x XLR (3 broches femelle)Type SPDIF-AESEBU (AES3)
Sortie numeacuterique ndeg1x XLR (3 broches macircle )Type conforme agrave la norme de lentreacutee
EntreacuteesSortie Rdnet ndeg2 x XLR RJ45 (cacircble CAT 5)USB Type B
PARAMETRES DE CONTROLE DU SONGain -80dB a +20dB eacutetape 01dBDeacutelai Entreacutee 0 a 729mS eacutetape 01 mS
Sortie 0 a 340mS eacutetape 01mSRotation de phase 0deg - 180deg
COMPRESSIONSeuil -80dB a +20dB eacutetape 01dBRapport 11 a Inf1 eacutetape 001Gain agrave la sortie 0dB a 40dB eacutetape 01dBTemps dattaque 1mS a 1000mS eacutetape 01mSTemps de relacircchement 1mS a 1000mS eacutetape 01mSTemps de maintien 1mS a 1000mS eacutetape 01mS
EGALISEURS12 eacutegaliseurs pour chaque entreacutee et sortieType PEQ (parameacutetrique) Hi-shelf Lo-sheft
Freacutequence 20Hz a 20KHz eacutetape 1HzGain -30dB a +15dB eacutetape 001dBBande 005dB a 2dB eacutetape 001dB (uniquement pour PEQ)
FILTRES CROSSOVERFiltre Linkwitz Riley
Type HF high-shelfLF low-shelf
Pente 12dBoct - 24dBoct - 48dBoctFreacutequence de coupure 5Hz a 20KHz eacutetape 1Hz
ALIMENTATION Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)POIDS 19Kg
Remarques Speacutecifications sujettes agrave modifications sans preacuteavis
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
2 VIE ATTIVO2 WAY ACTIVE
3 VIE PASSIVO3 WAY PASSIVE
L
L
A
A
HIGH L
MID L
LOW HIGHMID RHIGHMID L
LOW L
HIGH R
MID R
LOW R
R
R
B
B
1
1
2
2
3
3
456
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
Menu Matrix configurationMatrix
57 58
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
EROUIG ATRIX TNM
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
OU
TP
UT
1
OU
TP
UT
2
OU
TP
UT
3
OU
TP
UT
4
OU
TP
UT
5
OU
TP
UT
6
AE
S-E
BU
OU
TP
UT
INP
UT
A
AE
S-E
BU
INP
UT
INP
UT
B
D D D D D D
D D
A A A A A A
A SA
MP
LE
RA
TE
CO
NV
A
LIN
KA
BL
E
SC
HE
MA
A B
LO
CC
HI -
BL
OC
K D
IAG
RA
MB
LO
CK
SC
HA
LT
BIL
D -
SC
HE
MA
S F
ON
CT
ION
NE
LS
LINE ARRAY SUB MONO ATTIVO
LINE ARRAY SUB MONO ACTIVEINGRESSI - INPUT
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
L
L
L
A
A
A
AESEBU IN
AESEBU IN
AESEBU IN
AESEBU OUT
AESEBU IN
AESEBU IN
AESEBU OUT
R
R
R
LR
B
B
B
123456
HIGHMID L
HIGHMID L HIGHMID R
HIGHMID R
LOW L LOW R
LAYER
DISPLAY MEMORY
FADER MODE
LAYER
DISPLAY MEMORY
FADER MODE
Ingresso ANALOGICO
ANALOG Input
Collegamento in cascata
Link connections
Ingresso DIGITALE
DIGITAL inputA B
BALANCED AUDIO INPUTS
-6dB
PUSH PUSH
IN OUT
AES EBUPUSH
Oppure
or
Oppure
or
Menu Option configurationOption
Menu Option configurationOption Menu Option configurationOption
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type Analog
AES out An In
Input type Analog
AES out An In
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
59 60
InA-B Src Dig InInA-B Src Dig InInA-B Src An InInA-B Src An In
frequenzaHz
dB
Gu
ad
ag
no
60 200 2800
0dB0dB
-6dB
Esempio di un sistema a 3-vie
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
Out 1 Out 2 Out 3
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Esempio di un sistema a 3-vie
61 62
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
26NAC 26NAC
R TE
DO
R
MO LEU O R CE S
E O TR L A
S O
O C ND I P
P hsuernE t
o su cti nF nel rS e tc o
E CSME UN
IGCHTE OL SN EOBd
ocaL l
M
0
484
467
430
44
31
75
12
7
DIMENSIONI DIMENSIONSABMESSUNGEN DIMENSIONS
INTRODUCTIONAC26N is a digital sound processor for the management of audio systems designed for fixed and touring installations AC26N uses the most modern technology with 2856 bit processors and high performance 24 bits ADDA converters The functions available in the processor are input and output levels delay polarity 12 equalization bands for each input and output channel multiple crossover and high performance limiter The control resolution of the filters is 1Hz Inputs and outputs can be set according to many configurations to meet any need AC26N can be controlled in real time and each one of its parameters can be configured on the front panel and through a computer by means of an intuitive graphical interface accessible through the software DVA Network and a dedicated RDnet or USB network connectionThe CPU and DSP software update via PC allows to keep the device up to date It is possible to save and recall 32 preset configurations
Package Contents- AC26N - Operating manual- Software CD- Power cord
Characteristics- 2 Inputs and 6 Outputs with flexible routing- AESEBU addressable stereo inputs and outputs - 2856 bit DSP- BURR-BROWN high performance 24 bit AD converters- Frequency resolution of the filters 1 Hz - 12 parametric equalizers for each input and output- 2 crossover filters for each output with selectable slope 122448 dBoct- High performance DRC multi configuration for limitercompression configuration of
each input and output- Adjustable level in dB polarity and delay for each input and output- Firmware Update via PC- Graphic LCD Display- 32 pre-sets can be stored by the user- USB interface for configuration and control via computer- RDnet interface that allows to control up to 256 remote devices
PC
PC
RDNET hub(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FUNCTIONS FRONT PANEL
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
CONTROLS AND FUNCTIONS
1) DISPLAYThe graphic LCD display allows to view and edit the AC26N information without a computer The display contrast can be set within the main menu
2) ldquoFunctions Selectorrdquo and ldquoPush Enterrdquo KNOBThis control allows to move select and change the parameters within the displayed menusRotation of the knob (Function Selector)- it allows to browse the menu pages- it allows to change the selected parametersPush the knob (Push Enter)- it allows to selectconfirm the parameters
3) ESC button This control allows to exit the displayed menus or to return to the previous view
4) MENU button This control allows to directly access the main menu
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
En
glis
hE
nglis
hu
ser
man
ual
user
man
ual
16
user
man
ual
user
man
ual
Englis
hE
nglis
h
15
DVA USB Manager
The firmware of the amplifier module can be updated via the USB portTo make this update possible and simple a dedicated program has been developed
It is recommended to download DVA USB Manager free software directly from dB Technologies (wwwdbtechnologiescom) in the special section laquoSoftware amp Controllerraquo
DVA Network
The AC26N is equipped with proprietary network interface called RDNET for PC interface through a device (RDNET control)For this purpose a proprietary communication protocol has been developed for receiving and sending data this connection permits real-time monitoring of the diffuser parameters such as output power amplifier temperature limiter status etc It is also possible to select various equalizations or create new ones set the desired volume levels using the specific plug-in
It is recommended to download DVA Network free software directly from dB Technologies (wwwdbtechnologiescom) in the special section laquoSoftware amp Controllerraquo DOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
REAR PANEL CONNECTIONS
1586 75 141210 11 13 169 17
14) USB connectorThis USB connector (type B) allows to connect the processor to a compute to check and update the firmware via a dedicated program (DVA Network)
15) ldquoMAINSrdquo POWER CONNECTIONIt allows to connect the provided power cord
16) FUSE HOLDER ldquoFUSErdquoMain power supply fuse housing
17) ldquoPOWERrdquo MAIN SWITCHThis switch allows to switch on and off the device
PUSH
P SHU
SHPU
P SHU
PUSH
CONNECTIONS
Analog Audio ConnectionsBalanced connections allow to minimize the cable induced noise so cable can be longerSuch connections may be used both on inputs and outputsXLR connector must be cabled with pin 1 to ground pin 2 to hot (+) and pin 3 to cold (-) With shielded cables connect the shield to pin 1XLR-XLR e XLR-Jack 14(63 mm) connection cables can be used to connect the AC26N
12
3
Input
XLR - female
Pin 3 =NegativeCold-VE Phase
Pin 3 =NegativeCold-VE Phase
1 2
3
Output
XLR - Male
Pin 2 = PositiveHot+VE Phase
Pin 2 = PositiveHot+VE Phase
Pin 2 = PositiveHot+VE Phase
Pin 2 = PositiveHot+VE Phase
Pin 1 =ScreenGroundEarth
Pin 1 =ScreenGroundEarth
Pin 1 =ScreenGroundEarth
Pin 1 =ScreenGroundEarth
Ring
Sleeve
Tip = PositiveHot+VE Phase
Ring = NegativeCold-VE Phase
Sleeve=ScreenGroundEarth
Sleeve=ScreenGroundEarth
Tip
The unbalanced connections can also be used However the cable induced noise increases and cable length must not exceed 5 metersSuch connections may be used both on inputs and outputsUnbalanced connection may lower the level of the input signal up to 6dB in order to overcome this drawback connect pin 3 to ground although this can increase the noise
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
18
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
17
CONTROLS AND FUNCTIONS
5) -6dB SELECTORThis selector allows to reduce all the analog XLR [6] input levels by 6 dB at the same time to compensate for the high output levels on the mixers or other audio devices When the input signal level bar on the display [1] remains always at full scale this means that the input signal level is excessive and a -6 dB attenuation is recommendedIn the Option menu it is possible to check when the selector is activated
6) INPUT CONNECTORS ldquoArdquo AND ldquoBrdquoInputs balanced at line levelCapable to accept XLR male connectors
7) OUTPUT CONNECTORS ldquo1rdquo ldquo2rdquordquo 3rdquo ldquo4rdquo ldquo5rdquo AND ldquo6rdquoOutputs balanced at line level Capable to accept XLR famale connectors
Be careful to correctly connect each output to each speaker or amplifier according to the settings of each channels to avoid damages and malfunctions
ldquoAESEBUrdquo Section
8) INPUT CONNECTORIn addition to the analog audio inputs a SPDIF-AESEBU (AES3) digital audio input is also provided It can be selected via the setup menuSuch input requires a balanced connection trough an XLR connector with a 110 ohm twisted 3-wires cable
9) ldquoOUTrdquo OUTPUT CONNECTORThis connector allows to forward audio signals available at the digital or analog inputs or outputs The source must be set by means of the Option menuThe connection must comply with the same standard of the input [8]
RDNET Section
10) DATA INPUT CONNECTORData input RJ45 connector
11) ldquoDATA LINKrdquo OUTPUT CONNECTORRJ45 connector for data output used for serial link in cascade
12) ldquoONrdquo INDICATOR LIGHTThis green indicator turns on only when the AC26N has recognized the RDNET main unit and it is connected to it via computer
13) ldquoACTIVErdquo INDICATOR LIGHTThis yellow indicator flashes when data transmission between RDNET and the device is active
12
3
Input
XLR - female
1 2
3
Output
XLR - Male
Tip Gambo
Tip= Signal
Pin 3 = Link to Pin 1
Pin 3 = Link to Pin 1
Digital Audio Connections (AESEBU)AESEBU (AES3 protocol) is and a balanced input electrically insulated by means of a transformer It allows carrying two audio channels in a single two-wires shielded cable The cable characteristics are twisted 3 poles impedance 100 ohm shielded equipped with XLR connector (AES3 standard)
RDnetEach RDNet port on Control 2 and Control 8 can be connected to maximum 32 cascade-connected compatible devices In the example below the control unit RDNET CONTROL 2 port is connected to the DATA INPUT of an AC 26N whose parallel DATA LINK output is sent to the input of the next AC26N In the example [n] is a number between 3 and 32 (maximum limit for the devices connected to a sub-network)
RJ 45
|1|2|3|4|5|6|7|8|
The overall length of a CAT5 sub-network cable cannot exceed 900 meters
The connector must be connected as follows
1 - Available for other functions (for example audio +) 2 - Available for other functions (for example audio -)3 - Available for other functions (for example analog ground)4 - digital ground5 - digital ground6 - Available for other functions (for example power supply)7 - RS 485 A8 - RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
POWER ON
When the device is turned on the initialization procedure starts It lasts few seconds The display shows the device model the company logo and a program loading progress bar
At the end of the installation process the display shows the Meters menu For further details about the indications refer to the paragraph MENU DESCRIPTION - METERS
AC26N is now ready for use
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION AND DISPLAY
To access the main menu window press the MENU key located on the device front panelIn any page of the menu press the ESC button to return to the previous screen
MAIN MENU
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
There are six menus in the processor They show andor configure the system parametersThe main menus are
Meters Input and output levels display program in progress display quick muting
Preset Store save and delete the system configurations
Matrix Select the outputs according to the input signal
Ch Job Configuration of each individual channel
X-Over Configuration of the cut-off frequency and the types of filters for each output
Option Assignment of the inputs and outputs display contrast firmware version inputs and other options
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
20
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
19
The menus and the individual options displayed can be selected by rotating the knob ldquoFUNCTION SELECTORrdquo ( ) To access the selection highlight the desired parameter and press the ldquoPush Enterrdquo ( | ) knobThe same procedure should be adoptd to select andor change the options inside each menu entry
MENU DESCRIPTION - ldquoMetersrdquo
This window allows to view the configuration and the general conditions of the inputs and outputs the version of the program used the program status and how the system is driven
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) INPUT AND OUTPUT CHANNELSThe input and output connectors are identified by the same information provided on the screen printing located on the device rear sideWith digital input signals the indications A and B concern the inputBy rotating the knob FUNCTION SELECTOR [2] input channels output channels and general muting indications are cyclically scrolled (d) the selected channel is highlighted
b) BAR COMPRESSION LEVEL CHANNEL MUTING
SIGNAL COMPRESSIONSignal compression is displayed by the vertical scrolling (top to down) of the right bar
MUTE Each channel can be individually muted Select the channel and press the Push Enter knob [2] to confirm the change of status The indication of the channel will be replaced by the letter M and the bar will be completely highlightedTo restore normal operation repeat the actions described above
c) SIGNAL LEVEL BARThe level indication for each channel is provided by scrolling the left bar
d) GENERAL MUTINGIt is possible to mute all the inputs and outputs simultaneously Rotate the knob FUNCTION SELECTOR select the letter M and press the Push Enter knobTo restore normal operation repeat the actions described aboveThe general mute has the highest priority with respect to the muting of individual channels
e) CONTROL MODEIt shows how the AC26N is used andor to which devices it is connected
Local = stand-alone usage No connection to an external device
NET = directly connected to dedicated RDnet network and to computer
USB = directly connected to another computer via USB cable
f) SETTING STATUS INDICATIONThis indication shows if the loaded program was amended in one or more parameters with respect to the last saving operation
= original program
= program with modified parameters
g) SET PROGRAMThe number shows the program that is loaded and used by the system with reference to the saving position Refer to the ldquoPresetrdquo menu for further details
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
MENU DESCRIPTION - CH JOB
This window allows to view the configuration of each individual channel
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) INPUT AND OUTPUT CHANNELSThe input and output connectors are identified by the same information provided on the screen printing located on the device rear side
b) SIGNAL LEVELIt shows the signal gain The increased signal intensity is expressed in decibels (dB) Such parameter can be selected in the range from -8000 dB to +2000 dB in steps of 001 dB An increase of 6 dB is approximately equal to doubling - in a linear scale - the signal voltage levelIf the gain exceeds 0 dB the signal is amplified while if the gain is lower than 0 dB the signal is attenuated
c) SIGNAL DELAYThe reproduced audio signal may be delayed to perform an acoustic alignment This compensates for the different positions of the speakers during the installation and the sound reproduction it is expressed in ms The parameter can be selected in the range from 00 ms to 729 ms in steps of 01 msThe following formula can be used to align an audio signal
Delay = (GAPx1000)344
Delay = ms (in milliseconds)GAP = distance between speaker and reference point (in meters)Speed of sound = 344 ms
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
22
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
21
d) MUTEEach channel can be individually muted The same command can be activated in the Meters Menu
NOTE The general mute has the highest priority with respect to the muting of individual channels
e) PhaseIt performs a phase rotation of 180deg with respect to the input signalSuch phase rotation allows the optimization in special way for low frequencies in complex installations
M M
f) EQUALIZATIONThis control opens the menu controlling the single channel equalization It is mainly used to correct one or more frequencies that must be reduced or increased
The AC26N manages 12 filters for each individual channel input and output with three different kinds of configuration
- PEQ Equaliser (peaking equalizer) ideal to identify isolate and correct only a certain range of frequencies All frequencies pass only those around the centre frequency are increased and decreased for a given bandwidth and set gain
- High-shelf Equalizer All frequencies pass but frequencies above the selected cut-off frequency are increased or attenuated by the given gain
- Low-shelf Equalizer All frequencies pass but frequencies below the selected cut-off frequency are increased or attenuated by the given gain
f Numbering of the 12 available filters for the specific input or output1
f Displays the kind of filter2
Dis Switched off (not present)
PEQ Peaking equlizer
Sh H High-shelf Filter
Sh L Low-shelf Filter
Examples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
NOTE
The parameter Bw defines the range of frequencies close to the set frequency where the filter is activated the greater the value of Bw the wider is the frequencies range (1 Bw = 1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONThis control opens the menu controlling the compression for the single channel
g1) ThresholdIdentifies the starting threshold for the compression ratio Base value 11
g2) RatioIndicates the conversion ratio between input and output signal
g3) Post Gain Attach Release HoldThese data are in function of the conversion ratio to achieve Post Gain is the output gain Attack is the attack time Release is the release time Hold is the holding time
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
24
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
23
MENU DESCRIPTION - PRESET
This window allows to store up to 32 configurations in the AC26NThe manufacturer provides the system with a program set and saved in position 0 that is not possible to overwrite
032 Indicates the location where the configuration is savedThis number also appears in the window Meters in position (g) The program in use can be displayed at any time by the user
Empty Preset It is the name associated with the location number when no setting is saved (empty)
Local preset It is the name associated with the location number when a setting is saved NOTE = It is possible to save a setting with the desired name up to 16 letters only via the computer interface
When a program is selected the following window is displayed
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
The name of the assigned program is displayed3 possible choices are available when working on the application
Save The program is saved in the AC 26N memory
Del The program is deleted
Load The program is loaded and ready to be used
MENU DESCRIPTION - X-OVER
This window allows to select for each output a low pass filter a high pass filter or create a band-pass filter via the combination of bothThe available filter is a Linkwitz-Riley where it is possible to select slopes of 12 dBoct 24 dBoct or 48 dBoct and their cut-off frequency
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) OUTPUT CHANNELS
The output connectors are identified by the same information provided on the screen printing located on the device rear side
b) CROSSOVER FILTERSelect the filter according to needs It is possible to select
Dis No filter enabled
HP High-pass filter set it to allow only the part of audio signal above the cut-off frequency
LP Low-pass filter set to allow only the part of audio signal below the cut-off frequency
Filter configuration Low-pass High-pass
Nothing Dis Dis
High-pass HP Dis
Low-pass Dis LP
Band-pass HP LP
12dBoct
24dBoct
Hz
dB
48dBoct
12dBoct
24dBoct
frequency
frequency
frequency
frequency
Hz
dB
48dBoct
c) ATTENUATION SLOPESelect the attenuation slope of the audio signal on the basis of the desired attenuation The higher the attenuation slope at the same cut-off frequency the greater the signal selection It is possible to select
12 equal to 12 dBoct
24 equal to 24 dBoct
48 equal to 48 dBoct
d) CUT-OFF FREQUENCYTo set the passing frequency for the lower frequencies only (low-pass filter) or the higher frequencies only (high-pass filter)The choice of the cut-off depends on the desired sound reproductionThe unit of measurement used is Hz
Hz
Hz
dB
dB
Ga
inG
ain
Ga
inG
ain
f0
f0
0dB0dB
0dB
-6dB
-6dB
0dB
0dB
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
26
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
25
MENU DESCRIPTION - MATRIX
For each output it allows to select the input signal to use as the source
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) OUTPUT CHANNELSIdentification of the output channel to set
b) IDENTIFICATIONS OF THE INPUTSIt selects the type of signal to match each output as needed It is possible to select
In A Associated with the input signal ldquoArdquo
In B Associated with the input signal ldquoBrdquo
In A+B Associated with the algebraic sum of the two input signals ldquoArdquo and ldquoBrdquo
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
MENU DESCRIPTION - OPTION
Allows to display the system settings such as the allocation of the inputs and outputs attenuation display contrast and firmware version
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcThis option allows to set the type of input audio signal
An In = Analog audio signals (inputs A and B)
DigIn = Digital audio signals (AESEBU input)
DigOut SrcThis option allows to select the audio source that will be forwarded to the connector AESEBU OUT (digital output)
An In = Audio signals available at analog inputs
Dig In = Audio signals available at digital inputs
OUT 1-2 = Audio signals available on outputs 1 and 2
OUT 3-4 = Audio signals available on outputs 3 and 4
OUT 5-6 = Audio signals available on outputs 5 and 6
Input ModeIt allows to configure the inputs
Indip = They are independent not subject to constraints of any kind between them
Linked = They are connected and work in stereo mode Compressors filters delays volume are identical for the two channels
Atten PadIt shows how to set the -6 dB switch located on the rear side [Ref 5] It is necessary to activate this selector when the analog input levels are too high The selector can be activated only by means of the button the menu is for display only
0 dB = Selector not activated The input signals are the same as the input source
-6 dB = Selector activated The input signals are attenuated by -6 dB with reference to the inner
processor
ContrastAllows to adjust the LCD display contrast to compensate for the brightness difference at the installation sites Greater display brightness allows to navigate correctly and quickly within the menuThe manufacturer output setting is 60
10 More bright 60 More dark 100
Fw VersIt shows the processor firmware version
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
28
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
27
TECHINICAL SPECIFICATION
AUDIO PERFORMANCEFrequency Response +- 01dB (20 to 30kHz)Dynamic Range 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistortion 0002 (1kHz +4dBu)
DIGITAL AUDIO PERFORMANCE Processor DSP 2856-bit Data processing Frequency 24-bit BURR BROWNAnalog converters 24-bit BURR BROWNPropagation Delay 15msStoring configurations 32 preset
CONTROLS Display LCD graficoButtonsControls ESC - MENU - FUNCTIONS SELECTION
ENTERINPUTSOUTPUTSAnalog Input ndeg2 x XLR (3 pole female)
Input impedance gt10KOhmMaximum Level +21dBu senza PAD
+27dBu con PADAnalog Output ndeg6 x XLR (3 pole male)
Output impedance 50OhmMaximum Level +21dBu Type Balanced
Digital Input ndeg1x XLR (3 pole female)Type SPDIF-AESEBU (AES3)
Digital Output ndeg1x XLR (3 pole male)Type Compliant with the input standard
RDnet InputsOutput ndeg2 x XLR RJ45 (CAT 5 cable)USB Tipo B
SOUND CONTROL PARAMETERSGain -80dB a +20dB step 01dBDelay
Input 0 a 729mS step 01 mSOutput 0 a 340mS step 01mSPhase Rotation 0deg - 180deg
COMPRESSIONThreshold -80dB a +20dB step 01dBRatio 11 a Inf1 step 001Output gain 0dB a 40dB step 01dBAttack time 1mS a 1000mS step 01mSRelease time 1mS a 1000mS step 01mSHold time 1mS a 1000mS step 01mS
EQUALIZERS12 equalizers for each input and outputType PEQ (parametrico) Hi-shelf Lo-sheft
Frequency 20Hz a 20KHz step 1HzGain -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (only with PEQ)
CROSSOVER FILTERSFilter Linkwitz Riley
Type HP High-pass LP Low-pass
Slope 12dBoct - 24dBoct - 48dBoctCUT-OFF FREQUENCY 5Hz a 20KHz passo 1Hz
POWER SUPPLY Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)
1719x17x51 inch (WxHxD)WEIGHT 19Kg
(42 lbs)Note Specifications subject to change without notice
EMI CLASSIFICATIONAccording to the standards EN 55103 this equipment is designed and suitable to operate in E3 (or lower E2 E1) Electromagnetic environments
EINLEITUNG
Verpackungsinhalt
Eigenschaften
AC26N ist ein digitaler Audio-Prozessor fuumlr die Verwaltung von Audio-Systemen der fuumlr feste und mobile Installationen entwickelt wurde AC26N benutzt die modernste Technologie mit 2856 bit-Prozessoren und 24-bit-ADDA-Wandlern mit hoher Leistungsfaumlhigkeit Die verfuumlgbaren Funktionen des Prozessors sind Ein- und Ausgangsstufen Verzoumlgerung (delay) Polaritaumlt 12 Equalizer-Frequenzen fuumlr Ein- und Ausgangskanal viele Crossover-Wahlmoumlglichkeiten und Limiter mit hoher Leistung Die Filter-Kontrolle hat eine Aufloumlsung von 1 Hz Die Ein- und Ausgaumlnge koumlnnen mit unterschiedlichen Einstellungen geregelt werden um allen Anforderungen gerecht zu werden AC26N kann in Echtzeit kontrolliert werden und jeder Parameter kann am Frontpaneel und vom Computer mit intuitiver graphischer Schnittstelle mittels Software DVA Network zugaumlnglich und einer Netzverbindung RDnet oder uumlber USB eingestellt werdenDie SW-Aktualisierung fuumlr CPU und DSP uumlber PC erlaubt die Vorrichtung auf dem aktuellen Stand zu halten Man kann 32 vorgesehene Konfigurationen speichern und aufrufen
- AC26N - Bedienungsanleitung- Software-CD- Versorgungskabel
- 2 Ein- und 6 Ausgaumlnge mit flexibler Adressierung- Adressierbarer Stereo-Ein- und Ausgang AESEBU - DSP 2856-bit- AD-Wandler BURR BROWN 24-bit mit hoher Leistungsfaumlhigkeit- Aufloumlsungsfrequenz der Filter 1 Hz - 12 parametrische Equalizer fuumlr jeden Ein- und Ausgang- 2 Crossover-Filter fuumlr jeden Ausgang mit auswaumlhlbarer Neigung 122448dBoct- DRC Multikonfiguration mit hoher Leistungsfaumlhigkeit fuumlr die Konfiguration des
Limitersder Kompression jedes Ein- und Ausgangs- Einstellbare dB-Stufe Polaritaumlt und Verzoumlgerung (delay) fuumlr jeden Ein- und Ausgang- Firmware-Aktualisierung uumlber PC- Graphisches LCD-Display- 32 Voreinstellungen vom Benutzer einstellbar- USB-Schnittstelle fuumlr die Kontrolle und Konfiguration mit dem Computer- Schnittstelle RDnet welche erlaubt bis zu 256 fern liegende Vorrichtungen
zu kontrollieren
PC
PC
RDNET control(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FUNKTIONEN VORDERSEITE
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
BEDIENUNGEN UND FUNKTIONEN
1) DISPLAYDas graphische LCD-Display erlaubt die Informationen des AC26N ohne einen Computer zu benutzen anzuzeigen und zu editieren Der Kontrast kann im Hauptmenuuml eingestellt werden
2) DREHGRIFF Functions Selector UND Push EnterDiese Kontrolle erlaubt sich in den Menuumls auf dem Display zu bewegen und die Parameter auszuwaumlhlen und zu veraumlndernDrehung des Drehgriffes (Functions Selectors)- Man kann sich innerhalb der verschiedenen Menuumlseiten bewegen- Erlaubt die Veraumlnderung der ausgewaumlhlten ParameterDruck des Drehgriffes (Push Enter)- Erlaubt die AuswahlBestaumltigung der Parameter
3) Taste ldquoESCrdquo Diese Kontrolle erlaubt die angezeigten Menuumls zu verlassen oder zur vorherigen Anzeige zuruumlckzukehren
4) Taste ldquoMenuumlrdquo Diese Kontrolle erlaubt den direkten Zugang zum Hauptmenuuml
Deuts
chD
euts
chB
ed
ien
un
gsan
leit
un
gB
ed
ien
un
gsan
leit
un
g
29
Deuts
chD
euts
chB
ed
ien
un
gsan
leit
un
gB
ed
ien
un
gsan
leit
un
g
30
DVA USB Manager
Die Firmware des Verstaumlrkermoduls kann uumlber den USB-Anschluss aktualisiert werdenUm diesen Vorgang zu ermoumlglichen und zu vereinfachen wurde ein dediziertes Programm entwickelt das beim Hersteller angefordert und auf einen Computer installiert werden muss
Wir empfehlen die Software DVA USB Manager direkt von der Webseite dB Technologies (wwwdbtechnologiescom) im Abschnitt laquoSoftware amp Controllerraquo herunterzuladen
DVA Network
AC26N ist mit einer eigenen als RDNET bezeichneten Netzschnittstelle ausgestattet dank der es uumlber ein Interface (RDNET Control) an einen Computer angeschlossen werden koumlnnenHierzu wurde ein Kommunikationsprotokoll entwickelt mit dem die Daten empfangen und gesendet werden Dank dieser Verbindung koumlnnen die Lautsprecherparameter wie Ausgangsleistung Verstaumlrkertemperatur Limiterstatus usw in Echtzeit kontrolliert werden Auszligerdem koumlnnen verschiedene Entzerrungen ausgewaumlhlt bzw neue erstellt werden oder die gewuumlnschte Lautstaumlrke eingestellt werden
Wir empfehlen die Software DVA_Network direkt von der Webseite dB Technologies (wwwdbtechnologiescom) im Abschnitt laquoSoftware amp Controllerraquo herunterzuladenDOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
RUumlCKWANDANSCHLUumlSSE
1586 75 141210 11 13 169 17
14) USB-SteckverbinderDieser USB-Steckverbinder (Typ B) erlaubt den Prozessor an einem Computer anzuschlieszligen um die Firmware mit dem speziellen Programm (DVA Network) zu kontrollieren und zu aktualisieren
15) STROMANSCHLUSS MAINSErlaubt den Anschluss des mitgelieferten Versorgungskabels
16) SICHERUNGSTRAumlGER FUSEAufnahme fuumlr die Netz-Sicherung
17) HAUPTSCHALTER POWERDer Schalter erlaubt das Aus- und Einschalten des Audio-Controllers
BEDIENUNGEN UND FUNKTIONEN
5) WAHLSCHALTER -6dBDer Wahlschalter erlaubt das Level des analogen Eingangs XLR [6] um 6 dB zu verringern und gleichzeitig das hohe Ausgangslevel der Mixer oder anderer Audio-Vorrichtungen auszugleichen Wenn der Balken des Signallevels der Eingaumlnge auf dem Display [1] immer auf Maximum steht zeigt dies an dass das Signallevel am Eingang hoch ist und es wird empfohlen die Daumlmpfung -6dB zu benutzenIm Menuuml Option ist es moumlglich zu kontrollieren ob der Wahlschalter aktiviert ist
6) STECKVERBINDER AM EINGANG A UND BAuf Leitungslinie ausgeglichene EingaumlngeSie koumlnnen auch XLR-Steckdosen aufnehmen
7) AUSGANG-STECKVERBINDER ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo UND ldquo6rdquoAuf Leitungslinie ausgeglichene Ausgaumlnge Sie koumlnnen auch XLR-Stecker aufnehmen
Darauf achten dass die Ausgaumlnge korrekt entsprechend der Einstellungen der einzelnen Kanaumlle an den Lautsprechern oder Verstaumlrkern angeschlossen sind um Schaumlden und Fehlfunktionen vorzubeugen
Abschnitt ldquoAESEBUrdquo
8) EINGANGS-STECKVERBINDER INZusaumltzlich zu den analogen Audio-Eingaumlngen wurde ein digitaler Audio-Eingang SPDIF-AESEBU (AES3) vorgesehen der uumlber das Setup-Menuuml ausgewaumlhlt werden kannDer Eingang erfordert einen ausgeglichenen Anschluss mit einem XLR-Steckverbinder mit einem verdrillten Kabel mit 3 Leitern von 110 Ohm
9) AUSGANGS-STECKVERBINDER OUTDieser Steckverbinder erlaubt das Audiosignal an den analogen oder digitalen Eingaumlngen oder Ausgaumlngen zu verteilen Die Quelle muss uumlber das Menuuml Option eingestellt werdenDer Anschluss muss demselben Standard des Eingang entsprechen [Ref 8]
Abschnitt ldquoRDNETrdquo
10) EINGANGS-STECKVERBINDER DATA INPUTSteckverbinder RJ45 fuumlr den Dateneingang
11) AUSGANGS-STECKVERBINDER DATA LINKSteckverbinder RJ45 fuumlr den Datenausgang Fuumlr die serielle Kaskaden-Verbindung
12) LEUCHTANZEIGE ONDiese gruumlne Anzeige leuchtet nur wenn AC26N uumlber den Computer mit der Haupteinheit RDNET verbunden ist und diese erkannt hat
13) LEUCHTANZEIGE ACTIVEDiese gelbe Anzeige blinkt wenn eine Datenuumlbertragung zwischen RDNET und der Vorrichtung aktiv ist
PUSH
P SHU
SHPU
P SHU
PUSH
ANSCHLUumlSSE
Analoge Audio-AnschluumlsseDie ausgeglichenen Anschluumlsse erlauben die Geraumlusche der Kabel auf ein Minimum zu verringern und so die Benutzung langer Kabel zuzulassenDiese Anschluumlsse koumlnnen sowohl an den Ein- als auch an den Ausgaumlngen benutzt werdenDer XLR-Steckverbinder muss mit Pin 1 an Masse Pin 2 am Pluspol (+) und Pin 3 am Minuspol (-) angeschlossen werden Bei einem abgeschirmten Kabel muss die Abschirmung an Pin 1 liegenDie Verbindungskabel XLR-XLR und XLR-Jack 14 (63 mm) koumlnnen fuumlr den Anschluss
12
3
Eingang
XLR weiblichen
Pin 3 = MinuspolErkaumlltungphase -VE
Pin 3 = MinuspolErkaumlltungphase -VE
1 2
3
Ausgang
XLR maumlnnlichen
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Ring
Schaft
Spitze = PluspolWaumlrmephase +VE
Ring = MinuspolErkaumlltungphase -VE
Schaft=SchirmMasse
Spitze
Die nicht ausgeglichenen Anschluumlsse koumlnnen auch benutzt werden wenn die Kabelgeraumlusche ansteigen und diese Kabel duumlrfen nicht laumlnger sein als 5 MeterDiese Anschluumlsse koumlnnen sowohl an den Ein- als auch an den Ausgaumlngen benutzt werdenDie nicht ausgeglichenen Anschluumlsse koumlnnen das Signallevel am Eingang um 6 dB verringern um dem vorzubeugen muss Pin 3 an Masse angeschlossen werden obwohl dies das Geraumlusch verstaumlrken kann
12
3
Eingang
XLR weiblichen
1 2
3
Ausgang
XLR maumlnnlichen
Spitze Schaft
Spitze = Signal
Schaft=SchirmMasse
Pin 3 = zu Pin 1 gebruumlckt
Pin 3 = zu Pin 1 gebruumlckt
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
31
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
32
Digitales Audio (AESEBU)AESEBU (Protokoll AES3) ist ein ausgeglichener und uumlber einen Transformator elektrisch isolierter Eingang Er erlaubt die Benutzung von zwei Kanaumllen an einem einzigen abgeschirmten bipolaren Kabel Das gedrillte Kabel muss 3-polig sein eine Impedanz von 100 Ohm haben und mit einem XLR-Steckverbinder (AES3 Standard) abgeschirmt sein
RdnetJeder Port RDNet an Control 2 und Control 8 kann an max 32 kompatiblen Vorrichtungen die in Kaskade geschaltet sind angeschlossen werden Im nachstehenden Beispiel ist der Port der Kontrolleinheit RDNET CONTROL 2 am Eingang DATA INPUT eines AC 26N angeschlossen dessen paralleler Ausgang DATA LINK zum Eingang des naumlchsten AC26N geht Im Beispiel ist [n] eine Nummer zwischen 3 und 32 (maximale Anzahl der anschlieszligbaren Vorrichtungen an nur einem Netz)
RJ 45
|1|2|3|4|5|6|7|8|
Die Gesamtlaumlnge des Kabels CAT5 eines Unternetzes kann NICHT laumlnger als 900 Meter sein
Der Steckverbinder muss wie folgt angeschlossen sein1 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio +) 2 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio -)3 ndash Verfuumlgbar fuumlr andere Funktionen (zB analoge Masse)4 ndash digitale Masse5 ndash digitale Masse6 ndash Verfuumlgbar fuumlr andere Funktionen (zB Versorgung)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
EINSCHALTEN
Beim Einschalten der Vorrichtung startet die Initialisierung die einige Sekunden lang dauert Auf dem Display wird das Modell das Logo und der Fortschrittsbalken der Ladung des Programms angezeigt
Nach der Initialisierung erscheint auf dem Display das Menuumlfenster Meters Um die Angaben im Detail zu erfahren beziehen Sie sich bitte auf das Kapitel BESCHREIBUNG DES MENUumlFENSTERS Meters
AC26N kann jetzt benutzt werden
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
MENUrsquo PRINCIPALE
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Die sechs Menuumls im Prozessor zeigen undoder konfigurieren die Systemparameter
Anzeige der Levels der Ein- und Ausgaumlnge Anzeige des benutzten Programms und dessen Status Mute schnell
Speicherung Speicherung und Eliminierung der Systemkonfigurationen
Auswahl der Ausgaumlnge je nach Eingangssignal
Konfiguration jedes einzelnen Kanals
Konfiguration der Schnittfrequenzen und der Filtertypen fuumlr jeden einzelnen Ausgang
Zuordnung der Ein- und Ausgaumlnge Kontrast des Displays Firmware-Version Eingaumlnge und andere Optionen
Das Menuuml und die einzelnen Optionen der Anzeige koumlnnen durch Drehen des Drehgriffes FUNKTIONS SELECTOR ( ) ausgewaumlhlt werden
Die Hauptmenuumls sind
Meters
Preset
Matrix
Ch Job
X-Over
Option
Um die Auswahl zu treffen muss der gewuumlnschte Parameter auswaumlhlt und der Drehgriff Push Enter( | ) gedruumlckt werdenDas selbe Verfahren muss fuumlr die Auswahl undoder die Aumlnderung der Optionen innerhalb der Menuumlpunkte angewendet werden
BESCHREIBUNG DES MENUumlFENSTERS Meters
Diese Seite erlaubt die Konfigurationen und den allgemeinen Status der Ein- und Ausgaumlnge der benutzten Programmversion dessen Status und die Steuerung des Systems anzuzeigen
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
KONFIGURATION UND ANZEIGE
Um in das Fenster des Hauptmenuumls zu gelangen muss die Taste Menuuml ( ) auf der Frontseite der Vorrichtung gedruumlckt werdenMit der Taste ESC ( ) kehrt man von jeder Seite des Menuumls auf die vorherige Seite zuruumlck
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
33
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
34
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziertBei den digitalen Eingangssignalen entspricht die Angabe A und B dem EingangDreht man den Drehgriff FUNCTIONS SELECTOR [2] durchlaumluft man zyklisch die Ein- und Ausgangskanaumlle und die Angabe Mute allgemein (d) der ausgewaumlhlte Kanal wird hervorgehoben
b) BALKEN FUumlR DAS KOMPRESIONSLEVELMUTE KANAL
SIGNALKOMPRESSIONDie Signalkompression wird durch das Gleiten des rechten Balkens von oben nach unten angezeigt
MUTE Jeder einzelne Kanal kann auf Mute gestellt werden Den Kanal auswaumlhlen und den Drehgriff Push Enter [2] druumlcken um die Aumlnderung des Status zu bestaumltigen Die Angabe des Kanals wird durch den Buchstaben M ersetzt und der Balken wird komplett hervorgehobenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werden
c) BALKEN DES SIGNALLEVELSDie Anzeige des Levels jedes einzelnen Kanals wird durch das Gleiten des linken Balkens angezeigt
d) MUTE ALLGEMEINEs ist moumlglich alle Ein- und Ausgaumlnge gleichzeitig auf Mute zu schalten Den Drehgriff FUNCTIONS SELECTOR drehen den Buchstaben M waumlhlen und dann den Drehgriff Push Enter druumlckenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werdenDie allgemeine Stummschaltung hat eine houmlhere Prioritaumlt als die Stummschaltung der einzelnen Kanaumlle
e) ANSTEUERUNGSARTENEs wird angezeigt wie AC26N benutzt wird undoder an welchen Vorrichtungen es angeschlossen ist
= Benutzung stand-alone Kein Anschluss an einer externen Vorrichtung
= Direkt am Netz RDnet und am Computer angeschlossen
= Uumlber USB-Kabel direkt am Computer angeschlossen
f) ANZEIGE DES STATUS DER EINSTELLUNGENHier wird angezeigt ob einer oder mehrere Parameter des geladenen Programms im Vergleich zur letzten Speicherung veraumlndert wurden
Original-Programm
Programm mit veraumlnderten Parametern
g) EINGESTELLTES PROGRAMMDie Nummer zeigt das vom System geladene und benutzte Programm in Bezug auf die Lokalisierung der Speicherung an Fuumlr weitere Details beziehen Sie sich bitte auf das Menuuml Preset
Local
NET
USB
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
BESCHREIBUNG DES MENUumlFENSTERS Ch Job
Dieses Fenster erlaubt die Anzeige der Konfiguration jedes einzelnen Kanals
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) SIGNALLEVELZeigt die Signalstaumlrke an Das Ansteigen der Signalintensitaumlt wird in Dezibel (dB) ausgedruumlckt Der Parameter kann zwischen -8000 dB und +2000 dB in Schritten von 001 dB ausgewaumlhlt werden Ein Anstieg von 6 dB ist fast gleich eine Verdoppelung in linearer Skala des Spannungswertes des SignalsBei einer Staumlrke von 0 dB wird das Signal verstaumlrkt waumlhrend es ein einer Staumlrke von weniger als 0 dB abgeschwaumlcht wird
c) VERZOumlGERUNG DES SIGNALS (DELAY)Das wiedergegebene Audio-Signal kann verzoumlgert werden um die akustische Ausrichtung zu erlauben Dies gleicht die verschiedenen Positionen der Lautsprecher bei der Installation und Klangwiedergabe aus und wird in mS ausgedruumlckt Der Parameter kann zwischen 00 mS und 729 mS in Schritten von 01mS ausgewaumlhlt werden
Um ein Audiosignal auszurichten kann folgende Formel benutzt werden
Verzoumlgerung = GAPx1000)344
Verzoumlgerung = mS (in Millisekunden ausgedruumlckt)GAP = Abstand des Lautsprechers vom Referenzpunkt (in Metern ausgedruumlckt)Klanggeschwindigkeit = 344 ms
d) MUTEJeder einzelne Kanal kann auf Mute gestellt werden Derselbe Befehl kann im Fenster des Menuumls Meters aktiviert werden PS Die al lgemeine Stummschaltung hat eine houmlhere Priori taumlt als die Stummschaltung der einzelnen Kanaumlle
e) PHASEErlaubt die Phasenrotation um 180deg zum EingangssignalDiese Rotation erlaubt vor Allem die Optimierung der niederen Frequenzen bei komplexen Installationen
f) ENTZERRUNGENDieser Befehl oumlffnet das Menuumlfenster fuumlr die Entzerrung des einzelnen Kanals Er wird vor Allem benutzt um eine oder mehrere Frequenzen zu korrigieren die gedaumlmpft oder verstaumlrkt werden muumlssen
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
35
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
36
AC26N verwaltet 12 Filter fuumlr jeden einzelnen Ein- und Ausgangskanal mit drei verschiedenen Konfigurationen- Equalizer PEQ (peaking equalizer) ist ideal um nur ein bestimmtes Frequenzband
zu identifizieren zu isolieren und zu korrigieren Es gehen alle Frequenzen durch aber nur die um die mittlere Frequenz steigt und sinkt um eine bestimmte Bandbreite und eine bestimmte Staumlrke
- Equalizer High-Shelf geht alle Frequenzen durch aber die Frequenzen uumlber der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
- Equalizer Low-Shelf geht alle Frequenzen durch aber die Frequenzen unter der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
f Nummerierung der 12 verfuumlgbaren Filter fuumlr diesen Ein- oder Ausgang1
f2 Es wird der Filtertyp angezeigt
Dis Ausgeschaltet (nicht vorhanden)
PEQ Peaking equalizer
Sh H Filter High-Shelf
Sh L Filter Low-shelf
Beispiele PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
ANMERKUNGDer Parameter Bw legt das Frequenzfeld neben der eingestellten Frequenz fest wo der Filter aktiviert wird je houmlher der Bw-Wert desto houmlher das Frequenzfeld (1Bw=1 Oktave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filter High-Shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filter Low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) KOMPRESSIONDieser Befehl oumlffnet das Menuumlfenster fuumlr die Kompression des einzelnen Kanals
g1) TresholdIdentifiziert die Schwelle an der das Kompressionsverhaumlltnis beginnt Der Basiswert 11
g2) RatioIdentifiziert das Kompressionsverhaumlltnis zwischen dem Ein- und Ausgangssignal
g3) Post Gain Attach Release HoldDiese Daten entsprechen dem Kompressionsverhaumlltnis das man erreichen moumlchte
Post Gain ist der Gewinn am AusgangAttack ist die Anschlusszeit Release ist die ReleasezeitHold ist die Beibehaltungszeit
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
BESCHREIBUNG DES MENUumlFENSTERS Preset
Dieses Fenster erlaubt bis zu 32 Konfigurationen im AC26N zu speichernDer Hersteller liefert das System mit einem voreingestellten Programm das auf Position 0 gespeichert ist und nicht uumlberschrieben werden kann
032 Es zeigt die Lokalisierung der Speicherung der KonfigurationDiese Nummer erscheint auch im Fenster Meters auf der Position (g) Das benutzte Programm kann jederzeit vom Benutzer angezeigt werden
Empty Preset Es ist der Name der der Nummer der Lokalisierung zugeordnet wird wenn keine Einstellung gespeichert ist (leer)
Local preset Es i s t de r Name de r de r Nummer de r Loka l i s i e rung zugeordnet wird wenn eine Konfiguration gespeichert wird
ANMERKUNG = Man kann eine Einstellung mit dem gewuumlnschten Namen mit max 16 Buchstaben nur speichern wenn man die Schnittstelle uumlber den Computer benutzt
Bei der Wahl eines Programms erscheint folgendes Fenster
Anzeige des Namens der dem Programm zugeordnet istUm auf die Anwendung einzuwirken stehen 3 Auswahlmoumlglichkeiten zur Verfuumlgung
Das Programm wird im Speicher des AC 26N gespeichert
Das Programm wird geloumlscht
Das Programm wird geladen und ist bereit fuumlr die Benutzung
Save
Del
Load
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
37
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
38
BESCHREIBUNG DES MENUumlFENSTERS X-Over
Dieses Fenster erlaubt fuumlr jeden Ausgang einen Bassdurchgangsfilter einen Hochdurchgangsfilter oder mittels Kombination von beiden einen Banduumlbergangsfilter zu waumlhlenDer Filter ist ein Linkwitz-Riley wo man die Neigung von 12 dBoct 24dBoct oder 48 dBoct und die entsprechende Schnittfrequenz auswaumlhlen kann
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) AUSGANGSKANAumlLE
Die Steckverbinder am Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) FILTER CROSSOVERDen Filter nach Bedarf waumlhlen Man kann folgendes auswaumlhlen
Dis Kein Filter aktiviert
HP Hochdurchgangsfilter nur den Teil des Audiosignals durchlassen der uumlber der Schnittfrequenz liegt
LP Bassdurchgangsfilter nur den Teil des Audiosignals durchlassen der unter der Schnittfrequenz liegt
Filter-Konfiguration Tiefpass Hochpass
Nichts Dis Dis
Hochpass HP Dis
Tiefpass Dis LP
Bandpass HP LP
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
c) DAumlMPFUNGSNEIGUNGDie Daumlmpfungsneigung des Audiosignals auf der Basis der Verringerung auswaumlhlen die man erreichen moumlchte Je houmlher die Daumlmpfungsneigung bei gleicher Schnittfrequenz desto groumlszliger ist die Signalauswahl Man kann folgendes waumlhlen
12 entsprechend 12 dboct
24 entsprechend 24 dboct
48 entsprechend 48 dboct
d) SCHNITTFREQUENZErlaubt die Durchgangsfrequenz der niederen Frequenzen (Bassdurchgangsfilter) oder der hohen Frequenzen (Hochdruchgangsfilter) einzustellenDie Auswahl des Schnitts bezieht sich auf die Wiedergabe die man erreichen moumlchteDie benutzte Maszligeinheit ist Hz
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
BESCHREIBUNG DES MENUumlFENSTERS Matrix
Erlaubt fuumlr jeden Ausgang das Eingangssignal zu waumlhlen das als Quelle benutzt werden soll
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) AUSGANGSKANAumlLEIdentifizierung des einzustellenden Ausgangskanals
b) IDENTIFIZIERUNG DER EINGAumlNGEDen Signaltyp auswaumlhlen der nach eigener Anforderung jedem einzelnen Ausgang zugeordnet werden soll Man kann folgendes waumlhlen
In A Das Signal wird dem Eingang A zugeordnet
In B Das Signal wird dem Eingang B zugeordnet
In A+B Zuordnung der a lgebra ischen Summe der be iden Eingangssignale A und B
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
BESCHREIBUNG DES MENUumlFENSTERS Option
Erlaubt die Anzeige der Systemeinstellungen wie die Zuordnung der Ein- und Ausgaumlnge Daumlmpfung Displaykontrast und Firmware-Version
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B Src
Diese Option erlaubt die Einstellung des Audio-Signaltyps am Eingang
Analoge Audiosignale (Eingaumlnge A und B)
Digitale Audiosignale (Eingang AESEBU)
DigOut Src
An In =Audiosignale an den analogen Eingaumlngen
Dig In =Audiosignale am digitalen Eingang
OUT 1-2 =Audiosignale an den Ausgaumlngen 1 und 2
OUT 3-4 =Audiosignale an den Ausgaumlngen 3 und 4
OUT 5-6 =Audiosignale an den Ausgaumlngen 5 und 6
Input Mode
An In
Dig In
Indip =
Linked =
Diese Option erlaubt die Audioquelle zu waumlhlen die fuumlr den Steckverbinder AESEBU OUT (digitaler Ausgang) bestimmt ist
Erlaubt die Eingaumlnge zu konfigurieren
Sie sind unabhaumlngig und selbststaumlndig sie unterliegen keinen Verpflichtungen untereinander Sie sind verbunden und funktionieren im Stereo-Modus
Die Kompressoren Filter Verzoumlgerungen die Lautstaumlrke sind bei beiden Kanaumllen identisch
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
39
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
40
Atten PadZeigt an wie der Wahlschalter -6 dB auf der Ruumlckseite eingestellt ist [Ref 5] Dieser Wahlschalter muss aktiviert werden wenn das Level an den analogen Eingaumlngen zu hoch ist Der Wahlschalter wird uumlber die Taste aktiviert im Menuuml gibt es nur eine Anzeige
0dB = Wahlschalter nicht aktiviert
-6dB = Wahlschalter aktiviert
Contrast
10 heller 60 dunkler 100
Fw Vers
Die Eingangssignale sind dieselben wie die Eingangsquelle
Die Eingangssignale werden vom internen Prozessor um -6 dB gedaumlmpft
Erlaubt den Kontrast des LCD-Displays einzustellen um den Unterschied der Helligkeit auf den Installationsort auszurichten Ein deutlicheres Display erlaubt auf korrekte und schnelle Weise innerhalb der Menuumls zu surfenDie Hersteller-Einstellung am Ausgang liegt bei 60
Zeigt die Firmware-Version des Prozessors an
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
41
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
42
TECHNISCHE DATEN
Antwort in FrequenzDynamische GammaCMMRCrosstalkDistorsion
ProzessorFrequenz der DatenausarbeitungAnaloge Converter Verzoumlgerung der VerteilungSpeicherung der Konfigurationen
DisplayTastenBedienungen
Analoger Eingang ndeg2 x XLR (3-poliger Female Stecker)Impedanz des Eingangs gt10KOhmMaximales Level +21dBu ohne PAD
+27dBu bei PAD
Impedanz des Ausgangs 50OhmMaximales Level +21dBu Typ symmetrisch
Typ SPDIF-AESEBU (AES3)
Typ Entsprechend dem Standard des Eingang
Typ
Typ
NETZSPANNUNGABMESSUNGEN (BXHXT)GEWICHT
AUDIO-LEISTUNGEN+- 01dB (20 to 30kHz)116dB typgt 60dB (50 to 10kHz)lt -100dB0002 (1kHz +4dBu)
DIGITALE AUDIO-LEISTUNGEN DSP 2856-bit 48KHz24-bit BURR BROWN15ms32 preset
KONTROLLEN LCD GrafikESC - MENU - FUNCTIONS SELECTIONENTER
EIN-AUSGAumlNGE
Analoger Ausgang ndeg6 x XLR (3-poliger Male Stecker)
Digitaler Eingang ndeg1x XLR (3-poliger female Stecker)
Digitaler Ausgang ndeg1x XLR (3-poliger Male Stecker)
Ein-Ausgang Rdnet ndeg2 x XLR RJ45 (kabel CAT 5) USB Typ B
KONTROLLPARAMETER AUDIOStaumlrke -80dB a +20dB step 01dBVerzoumlgerung Eingang 0 a 729mS step 01 mS
Ausgang 0 a 340mS step 01mSPhasenrotation 0deg - 180deg
KOMPRESSIONSchwelle -80dB a +20dB step 01dBVerhaumlltnis 11 a Inf1 step 001Staumlrke am Ausgang 0dB a 40dB step 01dBAnschlusszeit 1mS a 1000mS step 01mSReleasezeit 1mS a 1000mS step 01mSBeibehaltungszeit 1mS a 1000mS step 01mS
EQUALIZER12 Equalizer fuumlr jeden Ein- und Ausgang
PEQ (parametrischer) Hi-shelf Lo-sheftFrequenz 20Hz a 20KHz step 1HzStaumlrke -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (lediglich PEQ)
FILTER CROSSOVERFilter Linkwitz Riley
HP HochdurchgangsfilterLP Bassdurchgangsfilter
Neigung 12dBoct - 24dBoct - 48dBoctSchnittfrequenz 5Hz a 20KHz step 1Hz
Full-range 100-240Vac 50-60Hz430482x43x130mm 19Kg
AnmerkungenSpezifikationen unterliegen Aumlnderungen ohne Vorankuumlndigung
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
INTRODUCTIONAC26N est un processeur audio numeacuterique pour la gestion de leacutequipement audio conccedilu pour des installations fixes et mobiles Il fonctionne selon une technologie de pointe avec des processeurs agrave 2856bits et des convertisseurs ADDA agrave 24-bits hautes performances Les fonctions du processeur sont les niveaux dentreacutee et de sortie le deacutelai (delay) la polariteacute 12 bandes deacutegalisation par canal dentreacutee et de sortie diffeacuterentes seacutelections de croisement (crossover) et un limiteur hautes performances Le controcircle des filtres a une reacutesolution de 1Hz Les entreacutees et les sorties peuvent ecirctre programmeacutees en plusieurs configurations pour satisfaire tous les besoins AC26N peut ecirctre controcircleacute en temps reacuteel et tous les paramegravetres peuvent ecirctre configureacutes depuis le pupitre frontale et par ordinateur avec interface graphique intuitive accessible via le logiciel laquoDVA Networkraquo et une connexion de reacuteseau deacutedieacutee RDnet ou USBLa mise agrave jour du logiciel pour lUniteacute centrale et DSP par ordinateur portable permet de maintenir le dispositif actualiseacute Il est possible denregistrer et de rappeler 32 configurations preacute-eacutequipeacutees de configuration
Contenu de lemballage - AC26N - Mode demploi- CD logiciel- Cacircble dalimentation
Caracteacuteristiques- 2 entreacutees et 6 sorties avec adressage flexible- Entreacutee et sortie steacutereacuteo AESEBU adressables - DSP 2856-bit- Convertisseurs AD BURR BWOWN 24-bit hautes performances- Freacutequence de reacutesolution des filtres 1 Hz - 12 eacutegaliseurs parameacutetriques pour chaque entreacutee et sortie- 2 filtres de croisement par sortie avec pente seacutelectionnable agrave 122448dBoct- DRC agrave configuration multiple hautes performances pour configuration limiteur
compression pour chaque entreacutee et sortie- Niveau reacuteglable en dB polariteacute et deacutelai pour chaque entreacutee et sortie- Mise agrave jour du micrologiciel par lordinateur- Affichage graphique agrave cristaux liquides- 32 preacutereacuteglages enregistrables par lutilisateur- Interface USB pour le controcircle et la configuration par ordinateur- Interface RDnet permettant de controcircler jusquagrave 256 dispositifs agrave distance
PC
PC
RDNETcontrol(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FONCTIONS DE LA FACE AVANT
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
COMMANDES ET FONCTIONS1) AFFICHAGE
Laffichage graphique agrave cristaux liquides permet de visualiser et deacutediter les informations de lAC26N sans utiliser lordinateur Le contraste peut ecirctre configureacute dans le menu principal
2) MANETTE Functions Selector et Push EnterCe controcircle permet de se deacuteplacer de seacutelectionner et de modifier les paramegravetres dans les menus affichables agrave leacutecranRotation de la manette (Functions Selectors)- permet de se deacuteplacer sur les diffeacuterentes pages du menu - permet de modifier les paramegravetres seacutelectionneacutesPression de la manette (Push Enter)- permet de seacutelectionnervalider les paramegravetres
3) Bouton ESC Ce controcircle permet de quitter les menus afficheacutes ou de revenir agrave la visualisation preacuteceacutedente
4) Bouton Menu Ce controcircle permet dacceacuteder directement au menu principal
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
Fra
nccedilais
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
43
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
Fra
nccedilais
44
DVA Network
AC26N est eacutequipeacute dune interface de reacuteseau proprieacutetaire deacutenommeacutee RDNET au moyen de laquelle il est possible de sinterfacer agrave lordinateur agrave travers un peacuteripheacuterique (RDNET control)
Pour cela un protocole de communication a eacuteteacute deacuteveloppeacute avec lequel il est possible de recevoir et denvoyer les donneacutees ce branchement permet de faire le monitorage en temps reacuteel des paramegravetres du diffuseur comme puissance de sortie tempeacuterature de lamplificateur eacutetat du limiteur etc Il est aussi possible de seacutelectionner diffeacuterentes eacutegalisations ou den creacuteer de nouvelles et de reacutegler les niveaux de volume souhaiteacutes au moyen dun plug-in approprieacute
On conseille de teacuteleacutecharger gratuitement le logiciel DVA Network directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
DVA USB Manager
On conseille de teacuteleacutecharger gratuitement le logiciel DVA USB Manager directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
Le micrologiciel du module amplificateur peut ecirctre remis agrave jour par le port USBPour rendre cette mise agrave jour possible et facile un programme speacutecifique a eacuteteacute deacuteveloppeacute
DOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
CONNEXIONS DU PANNEAU ARRIEgraveRE
1586 75 141210 11 13 169 17
14) Connecteur ldquo USBrdquoCe connecteur USB (type B) permet de connecter le processeur agrave un ordinateur pour le controcircle et la mise agrave jour du micrologiciel via un programme deacutedieacute (DVA Network)
15) PRISE DALIMENTATION MAINSPermet la connexion du cacircble dalimentation fourni de seacuterie
16) PORTE-FUSIBLE FUSELogement pour fusible de ligne
17) INTERRUPTEUR GENERAL POWERLinterrupteur permet de mettre en marche ou deacuteteindre le controcircleur audio
COMMANDES ET FONCTIONS
5) SELECTEUR ldquo-6dBrdquoLe seacutelecteur permet de reacuteduire de 6dB les niveaux dentreacutee analogiques XLR [6] tout en compensant les niveaux eacuteleveacutes de sortie des meacutelangeurs ou dautres dispositifs audio Quand la barre du niveau de signal des entreacutees sur laffichage [1] reste au maximum cela indique que le niveau du signal entrant est eacuteleveacute Il est alors conseilleacute dutiliser latteacutenuation -6dBIl est possible de veacuterifier quand le seacutelecteur est activeacute par le menu Option
6) CONNECTEURS DENTREE ldquoArdquo ET ldquoBrdquoEntreacutees eacutequilibreacutees au niveau de la ligneIls sont en mesure daccepter des connecteurs XLR macircles
7) CONNECTEURS DE SORTIE ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo ET ldquo6rdquoSorties eacutequilibreacutees au niveau de la ligne Ils sont en mesure daccepter des connecteurs XLR femelles
Prendre garde agrave brancher convenablement les sorties sur les diffuseurs ou les amplificateurs en fonction des configurations de chaque canal pour eacuteviter des deacutegacircts et des problegravemes de fonctionnement
Section ldquoAESEBUrdquo
8) CONNECTEUR DENTREE INOutre les entreacutees audio analogiques une entreacutee audio numeacuterique SPDIF-AESEBU (AES3) a eacuteteacute preacutevue et peut ecirctre seacutelectionneacutee par le menu de setupLentreacutee requiert une connexion eacutequilibreacutee en utilisant un connecteur XLR avec un cacircble agrave 3 conducteurs de 110ohm torsadeacute
9) CONNECTEUR DE SORTIE OUTCe connecteur permet de relancer le signal audio dans les entreacutees analogiques ou numeacuteriques ou sur les sorties La source doit ecirctre reacutegleacutee par le menu OptionLa connexion sera conforme agrave la mecircme norme que lentreacutee [reacutef8]
Section ldquoRDNETrdquo
10) CONNECTEUR DENTREE DATA INPUTConnecteur RJ45 entreacutee de donneacutees
11) CONNECTEUR DE SORTIE DATA LINKConnecteur RJ45 sortie de donneacutees pour la connexion de seacuterie en cascade
12) VOYANT LUMINEUX ONCe voyant de couleur verte sallume uniquement quand lAC26N a reconnu et est connecteacute agrave luniteacute principale RDNET par lordinateur
13) VOYANT LUMINEUX ACTIVECe voyant de couleur jaune clignote quand une transmission des donneacutees est active entre RDNET et le dispositif
PUSH
P SHU
SHPU
P SHU
PUSH
CONNEXIONS
Audio analogiquesLes connexions eacutequilibreacutees permettent de reacuteduire au minimum le bruit provoqueacute par les cacircbles et dutiliser de longs cacircblesCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLe connecteur XLR doit ecirctre brancheacute avec la broche 1 agrave la masse la broche 2 au chaud (+) et la broche 3 au froid (-) En cas de cacircble blindeacute brancher le blindage agrave la broche 1Les cacircbles de connexion XLR-XLR et XLR-Jack14(63mm) peuvent semployer pour la connexion agrave lAC26N
12
3
Entreacutee
Entreacutee
XLR - femme
XLR - femme
1 2
3
Sortie
Sortie
XLR - Macircle
XLR - Macircle
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2 = Point chaudPhase +VE
Broche 3 =Point froidPhase -VE
Broche 3 =Point froidPhase -VE
Anneau
Manchon
Pointe Point chaudPhase +VE
Anneau = Point froidPhase -VE
ManchonB Masselindeacute
Pointe
Les connexions deacuteseacutequilibreacutees peuvent semployer mecircme si le bruit provoqueacute par les cacircbles augmente Les cacircbles ne peuvent deacutepasser 5m de longCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLes connexions deacuteseacutequilibreacutees peuvent abaisser le niveau du signal entrant de 6dB Pour remeacutedier agrave cet inconveacutenient il faut brancher la broche 3 agrave la masse mecircme si cela augmente le bruit
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
45
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
46
12
3
1 2
3
Pointe Manchon
Pointe = Signal
Broche 3 = Link to Pin 1
Broche 3 = Link to Pin 1
ManchonB Masselindeacute
Audio numeacuteriques (AESEBU)
AESEBU (protocole AES3) est une entreacutee eacutequilibreacutee isoleacutee eacutelectriquement agrave laide dun transformateur Elle permet demployer deux canaux audio dans un seul cacircble bipolaire blindeacute Les caracteacuteristiques du cacircble doivent ecirctre de 3 pocircles impeacutedance 100ohm torsadeacute et blindeacute avec connecteur XLR (AES3 standard)
RJ 45
|1|2|3|4|5|6|7|8|
RDnet
Chaque port RDNet des Control 2 et Control 8 peut ecirctre brancheacute agrave un maximum de 32 dispositifs compatibles placeacutes en cascade Dans lexemple suivant le port de luniteacute de controcircle RDNET CONTROL 2 est relieacute agrave lentreacutee DATA INPUT dun AC26N dont la sortie parallegravele DATA LINK est envoyeacutee agrave lentreacutee de lAC26N successif Dans lexemple [n] est un nombre compris entre 3 et 32 (limite maximale des dispositifs que lon peut relier agrave un sous-reacuteseau)
La longueur totale du cacircble CAT5 dun sous-reacuteseau NE peut PAS deacutepasser 900 megravetres
Le connecteur doit ecirctre relieacute comme 1 ndash disponible pour dautres fonctions (par exemple audio +) 2 ndash disponible pour dautres fonctions (par exemple audio )3 ndash disponible pour dautres fonctions (par exemple masse analogique)4 ndash masse numeacuterique5 ndash masse numeacuterique6 ndash disponible pour dautres fonctions (par exemple alimentation)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
MISE EN MARCHE
Lors de la mise en marche du dispositif linitialisation deacutebute et dure quelques secondes Leacutecran affiche le modegravele le logo et la barre de progression du chargement du programme
En fin de processus dinstallation leacutecran affiche la fenecirctre du menu Meters Pour connaicirctre les indications en deacutetail consulter le paragraphe DESCRIPTION FENETRE MENU Meters
LAC26N est precirct agrave lemploi
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION ET VISUALISATION
Pour entrer dans la fenecirctre du menu principal il faut pousser sur la touche MENU ( ) agrave lavant du dispositifDune page quelconque du menu en poussant sur la touche ESCrdquo ( ) on revient automatiquement sur la page-eacutecran preacuteceacutedente
MENU PRINCIPAL
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Le processeur contient six menus Ils montrent etou configurent les paramegravetres du systegravemeLes menus principaux sont
Meters Visualisation des niveaux des entreacutees et des sorties visualisation du programme utiliseacute et eacutetat mute rapide
Preset Meacutemoriser enregistrer et eacuteliminer les configurations du systegraveme
Matrix seacutelectionner les sorties en fonction du signal entrant
Ch Job configuration de chaque signal
X-Over configurer les freacutequences de coupure et les types de filtres pour chaque sortie
Option attribution des entreacutees et des sorties contraste daffichage la version du micrologiciel les entreacutees et dautres options
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
47
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
48
DESCRIPTION DE LA FENETRE MENU Metersrdquo
Cette fenecirctre permet de visualiser les configurations et leacutetat geacuteneacuteral des entreacutees et des sorties la version du programme utiliseacute son eacutetat et le mode de pilotage du systegraveme
Les menus et les options afficheacutees peuvent se seacutelectionner en tournant la manette ldquoFUNCTIONS SETECTORrdquo ( ) Pour avoir accegraves agrave linteacuterieur de la seacutelection il faut mettre le paramegravetre souhaiteacute en eacutevidence et pousser sur la manette ldquoPush Enterrdquo ( | ) Il faut en faire de mecircme pour seacutelectionner etou modifier les options dans les commandes du menu
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositifAvec des signaux dentreacutee numeacuteriques les indications ldquoArdquo et ldquoBrdquo correspondent agrave lentreacuteeEn tournant la manette ldquoFUNCTIONS SELECTORrdquo [2] on fait deacutefiler en mode cyclique les canaux dentreacutee de sortie et lindication de mute geacuteneacuteral (d) le canal seacutelectionneacute est mis en eacutevidence
b) BARRE DE NIVEAU DE COMPRESSIONMUTE CANAL
COMPRESSION DE SIGNALLa compression du signal est visualiseacutee par le deacutefilement de la barre de droite de haut en bas
MUTE Chaque canal peut ecirctre placeacute en mute Seacutelectionner le canal et pousser sur la manette ldquoPush Enterrdquo [2] pour valider le changement deacutetat Lindication du canal sera remplaceacutee par la lettre M et la barre sera totalement mise en eacutevidencePour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterations
c) BARRE DE NIVEAU DE SIGNALLindication du niveau de chaque canal est signaleacutee par le deacutefilement de la barre de gauche
d) MUTE GENERALIl est possible de mettre simultaneacutement toutes les entreacutees et les sorties en mute Tourner la manette ldquoFUNCTIONS SELECTORrdquo seacutelectionner la lettre M et pousser sur la manette Push EnterPour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterationsLe mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) MODES DE COMMANDEIl affiche le mode dutilisation etou les dispositifs qui sont relieacutes agrave lAC26N
Local = utilisation autonome Aucune connexion agrave un dispositif exteacuterieur
NET = relieacute directement au reacuteseau deacutedieacute RDNet et agrave lordinateur
USB = relieacute directement agrave un ordinateur par cacircble USB
f) INDICATION DETAT DE PARAMETRAGECette indication permet de constater si un ou plusieurs paramegravetre(s) du programme chargeacute aont eacuteteacute modifieacute(s) par rapport au dernier sauvetage
= programme dorigine
= programme avec des paramegravetres modifieacutes
g) PROGRAMME CONFIGURELe chiffre indique le programme chargeacute et utiliseacute par le systegraveme agrave lemplacement de sauvetage Consulter le menu de Preset pour de plus amples deacutetails
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
DESCRIPTION DE LA FENETRE MENU Ch Job
Cette fenecirctre permet dafficher la configuration de chaque canal
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) NIVEAU DU SIGNALIndique le gain du signal Laugmentation de lintensiteacute dun signal est libelleacutee en deacutecibel (dB) Le paramegravetre peut ecirctre seacutelectionneacute de -8000dB agrave +2000dB avec des pas de 001dB Une augmentation de 6dB est eacutegale approximativement au redoublement agrave leacutechelle lineacuteaire du niveau du signal sous tensionAvec un gain supeacuterieur agrave 0dB le signal est amplifieacute tandis quavec un gain infeacuterieur agrave 0dB le signal est atteacutenueacute
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
49
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
50
c) DELAI DU SIGNAL (DELAY)Le signal audio reproduit peut ecirctre retardeacute pour permettre lalignement acoustique Cela compense les diffeacuterentes positions des diffuseurs pendant linstallation et la reproduction sonore Il se libelle en mS Le paramegravetre peut ecirctre seacutelectionneacute de 00mS agrave 729mS avec un pas de 01mSPour aligner un signal audio il est possible dutiliser la formule suivante
Deacutelai = (GAPx1000)344
Deacutelai = ms (en millisecondes)GAP = distance du diffuseur du point de reacutefeacuterence (en megravetres)Vitesse du son = 344ms
d) MUTEChaque canal peut ecirctre placeacute en mute La mecircme commande peut ecirctre activeacutee dans la fenecirctre du menu meters NB Le mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) PhasePermet la rotation de phase de 180deg par rapport au signal entrantCette rotation permet loptimisation surtout des basses freacutequences dans les installations complexes
f) EGALISATIONCette commande ouvre la fenecirctre du menu deacutegalisation de chaque canal Elle sert surtout pour corriger une ou plusieurs freacutequences qui doivent ecirctre atteacutenueacutees ou augmenteacutees
M M
LAC26N gegravere 12 filtres par canal dentreacutee et sortie avec trois types de configurations diffeacuterentes - Leacutegaliseur PEQ (peaking equalizer) est ideacuteal pour identifier isoler et
corriger une seule plage de freacutequences bien deacutetermineacutee Toutes les freacutequences passent mais il augmente ou diminue uniquement celles autour de la freacutequence centrale pour une bande preacutecise et un gain deacutefini
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessus de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessous de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
f Numeacuterotation des 12 filtres disponibles pour cette entreacutee ou cette sortie1
f Le type de filtre est afficheacute 2
Dis Deacutesactiveacute (absent)
PEQ Peaking equlizer
Sh H Filtre high-shelf
Sh L Filtre high-shelf
Exemples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
REMARQUELe paramegravetre Bw deacutetermine le champ de freacutequences adjacent agrave la freacutequence configureacutee ougrave est activeacute le filtre Plus la valeur Bw est eacuteleveacutee plus vaste est le champ de freacutequences (1Bw=1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONCette commande ouvre la fenecirctre du menu de compression de chaque canal
g1) TresholdIdentifie le seuil ougrave commence le rapport de compression La valeur de base 11
g2) RatioIndique le rapport de conversion entre le signal entrant et le signal sortant
g3) Post Gain Attach Release HoldCes donneacutees deacutependent du rapport de conversion que lon veut obtenir - Post Gain est le gain de sortie- Attack est le temps dattaque - Release est le temps de relacircchement- Hold est le temps de maintien
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
52
DESCRIPTION DE LA FENETRE MENU Preset
Cette fenecirctre permet de meacutemoriser jusquagrave 32 configurations dans lAC26NLe fabricant fournit le systegraveme avec un programme configureacute et enregistreacute en position 0 et non susceptible deacutecrasement
032 Elle indique lemplacement de sauvetage de la configurationCe numeacutero apparaicirct dans la fenecirctre Meters en position (g) A tout moment le programme utiliseacute peut ecirctre afficheacute par lutilisateur
Empty Preset Cest le nom qui est associeacute au numeacutero de lemplacement quand aucune configuration (vide) nest enregistreacutee
Local preset Local preset est le nom qui est associeacute au numeacutero de lemplacement quand on enregistre une configuration NB = Il est possible denregistrer une configuration avec lenom souhaiteacute de 16 lettres tout au plus agrave condition que lonutilise linterface via lordinateur
Le nom du programme assigneacute est indiqueacutePour toucher agrave lapplication 3 choix soffrent agrave vous
Save Le programme est enregistreacute en meacutemoire de lAC26N
Del Le programme est effaceacute
Load Le programme est chargeacute et precirct agrave lemploi
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
51
DESCRIPTION DE LA FENETRE MENU X-Over
Cette fenecirctre permet de seacutelectionner un filtre passe bas un filtre passe haut ou par la combinaison des deux de creacuteer un filtre passe bande pour chaque sortieLe filtre actif est un Linkwitz-Riley qui permet de seacutelectionner la pente de 12dBoct 24dBoct ou 48dBoct et sa freacutequence de coupure
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) CANAUX DE SORTIE
Les connecteurs de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) FILTRE CROSSOVERSeacutelectionner le filtre selon les besoins Il est possible de seacutelectionner
Dis Aucun filtre activeacute
HP Filtre passe-haut laisse passer uniquement la partie de signal audio supeacuterieure agrave la freacutequence de coupure
LP Filtre passe-bas laisse passer uniquement la partie de signal audio infeacuterieure agrave la freacutequence de coupure
Configuration du filtre Passe-haut Passe-bas
Rien Dis Dis
Passe-haut HP Dis
Passe-bas Dis LP
Passe-bande HP LP
12dBoct
24dBoct
Hz
dB
Ga
in 48dBoct
12dBoct
24dBoct
Hz
dB
Ga
in
48dBoct
c) PENTE DATTENUATIONSeacutelectionner la pente datteacutenuation du signal audio en fonction de la diminution que lon veut obtenir Plus la pente datteacutenuation est eacuteleveacutee agrave eacutegaliteacute de freacutequence de coupure plus eacuteleveacutee sera la seacutelection du signal Il est possible de seacutelectionner
12 correspond agrave 12dboct
24 correspond agrave 24dboct
48 correspond agrave 48dboct
d) FREQUENCE DE COUPUREElle permet de reacutegler la freacutequence de passage des freacutequences infeacuterieures (filtre passe-bas) ou des freacutequences supeacuterieures (filtre passe-haut) uniquementLe choix de la coupure deacutepend de la reproduction que lon veut obtenirLuniteacute de mesure utiliseacutee est lHz
Hz
Hz
dB
dB
Ga
in
f0
f0
0dB0dB
0dB
-6dB
freacutequence
freacutequence
freacutequence
freacutequence
Ga
in
f0
0dB
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
53
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
54
DESCRIPTION DE LA FENETRE MENU Matrix
Elle permet de seacutelectionner le signal entrant agrave utiliser comme source pour chaque sortie
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) CANAUX DE SORTIEIdentification du canal sortant agrave reacutegler
b) IDENTIFICATIONS DES ENTREESSeacutelectionner le type de signal agrave associer agrave chaque sortie en fonction des besoins Il est possible de seacutelectionner
In A Le signal entrant A est associeacute
In B Le signal entrant B est associeacute
In A+B La somme algeacutebrique des deux signaux entrants A et B est associeacutee
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
DESCRIPTION DE LA FENETRE MENU Option
Permet dafficher les reacuteglages du systegraveme comme lassignation des entreacutees et des sorties latteacutenuation le contraste de laffichage et la version du logiciel
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcCette option permet de reacutegler le type de signal audio entrant
An In =signaux audio analogiques (entreacutees ldquoArdquo et ldquoBrdquo)
Dig In =signaux audio numeacuteriques (entreacutee AESEBU)
DigOut SrcCette option permet de seacutelectionner la source audio qui sera adresseacutee sur le connecteur AESEBU OUT (sortie numeacuterique)
An In = signaux audio des entreacutees analogiques
Dig In =signaux audio sur lentreacutee numeacuterique
OUT 1-2 = signaux audio sur les sorties 1 et 2
OUT 3-4 = signaux audio sur les sorties 3 et 4
OUT 5-6 = signaux audio sur les sorties 5 et 6
Input ModePermet de configurer les entreacutees
Indip = sont indeacutependantes et autonomes Ne sont soumises agrave aucun type de lien
Linked = sont unies et fonctionnent en mode steacutereacuteo Les compresseurs les filtres les deacutelais le volume sont identiques pour les deux canaux
Atten PadIndique le mode de reacuteglage du seacutelecteur ldquo-6dBrdquo placeacute agrave larriegravere [reacutef 5] Il faut activer ce seacutelecteur quand les niveaux dentreacutee analogiques sont trop eacuteleveacutes Le seacutelecteur sactive uniquement par le bouton Dans le menu il sagit dune simple visualisation
0dB = seacutelecteur non activeacute Les signaux dentreacutee sont identiques agrave la source entrante
-6dB = seacutelecteur activeacute Les signaux entrants sont atteacutenueacutes de -6dB par le processeur interne
ContrastIl permet de reacutegler le contraste de laffichage agrave cristaux liquides pour compenser la diffeacuterence de luminositeacute avec le lieu dinstallation Une plus grande clarteacute de laffichage permet de naviguer convenablement et rapidement dans les menusLe reacuteglage agrave la sortie de lusine du fabricant est de 60
10 plus clair 60 plus fonceacute 100
Fw VersIndique la version du logiciel du processeur
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
55
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
56
DONNES TECHINIQUES
PERFORMANCES AUDIOReacuteponse en freacutequence +- 01dB (20 to 30kHz)Plage dynamique 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsion 0002 (1kHz +4dBu)
PERFORMANCES AUDIO NUMERIQUES Processeur DSP 2856-bit Freacutequence de traitement des donneacutees 48KHzConvertisseurs analogiques 24-bit BURR BROWNDeacutelai de propagation 15msMeacutemorisations des configurations 32 preset
CONTROLES Affichage LCD graficoBoutonsCommandes ESC - MENU - FUNCTIONS SELECTION
ENTERENTREESSORTIESEntreacutee analogique ndeg2 x XLR (3 broches femelle)
Impeacutedance dentreacutee gt10KOhmNiveau maximum +21dBu senza PAD
+27dBu con PADSortie analogique ndeg6 x XLR (3 broches macircle )
Impeacutedance de sortie 50OhmNiveau maximum +21dBuType Balanceacute
Entreacutee numeacuterique ndeg1x XLR (3 broches femelle)Type SPDIF-AESEBU (AES3)
Sortie numeacuterique ndeg1x XLR (3 broches macircle )Type conforme agrave la norme de lentreacutee
EntreacuteesSortie Rdnet ndeg2 x XLR RJ45 (cacircble CAT 5)USB Type B
PARAMETRES DE CONTROLE DU SONGain -80dB a +20dB eacutetape 01dBDeacutelai Entreacutee 0 a 729mS eacutetape 01 mS
Sortie 0 a 340mS eacutetape 01mSRotation de phase 0deg - 180deg
COMPRESSIONSeuil -80dB a +20dB eacutetape 01dBRapport 11 a Inf1 eacutetape 001Gain agrave la sortie 0dB a 40dB eacutetape 01dBTemps dattaque 1mS a 1000mS eacutetape 01mSTemps de relacircchement 1mS a 1000mS eacutetape 01mSTemps de maintien 1mS a 1000mS eacutetape 01mS
EGALISEURS12 eacutegaliseurs pour chaque entreacutee et sortieType PEQ (parameacutetrique) Hi-shelf Lo-sheft
Freacutequence 20Hz a 20KHz eacutetape 1HzGain -30dB a +15dB eacutetape 001dBBande 005dB a 2dB eacutetape 001dB (uniquement pour PEQ)
FILTRES CROSSOVERFiltre Linkwitz Riley
Type HF high-shelfLF low-shelf
Pente 12dBoct - 24dBoct - 48dBoctFreacutequence de coupure 5Hz a 20KHz eacutetape 1Hz
ALIMENTATION Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)POIDS 19Kg
Remarques Speacutecifications sujettes agrave modifications sans preacuteavis
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
2 VIE ATTIVO2 WAY ACTIVE
3 VIE PASSIVO3 WAY PASSIVE
L
L
A
A
HIGH L
MID L
LOW HIGHMID RHIGHMID L
LOW L
HIGH R
MID R
LOW R
R
R
B
B
1
1
2
2
3
3
456
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
Menu Matrix configurationMatrix
57 58
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
EROUIG ATRIX TNM
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
OU
TP
UT
1
OU
TP
UT
2
OU
TP
UT
3
OU
TP
UT
4
OU
TP
UT
5
OU
TP
UT
6
AE
S-E
BU
OU
TP
UT
INP
UT
A
AE
S-E
BU
INP
UT
INP
UT
B
D D D D D D
D D
A A A A A A
A SA
MP
LE
RA
TE
CO
NV
A
LIN
KA
BL
E
SC
HE
MA
A B
LO
CC
HI -
BL
OC
K D
IAG
RA
MB
LO
CK
SC
HA
LT
BIL
D -
SC
HE
MA
S F
ON
CT
ION
NE
LS
LINE ARRAY SUB MONO ATTIVO
LINE ARRAY SUB MONO ACTIVEINGRESSI - INPUT
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
L
L
L
A
A
A
AESEBU IN
AESEBU IN
AESEBU IN
AESEBU OUT
AESEBU IN
AESEBU IN
AESEBU OUT
R
R
R
LR
B
B
B
123456
HIGHMID L
HIGHMID L HIGHMID R
HIGHMID R
LOW L LOW R
LAYER
DISPLAY MEMORY
FADER MODE
LAYER
DISPLAY MEMORY
FADER MODE
Ingresso ANALOGICO
ANALOG Input
Collegamento in cascata
Link connections
Ingresso DIGITALE
DIGITAL inputA B
BALANCED AUDIO INPUTS
-6dB
PUSH PUSH
IN OUT
AES EBUPUSH
Oppure
or
Oppure
or
Menu Option configurationOption
Menu Option configurationOption Menu Option configurationOption
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type Analog
AES out An In
Input type Analog
AES out An In
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
59 60
InA-B Src Dig InInA-B Src Dig InInA-B Src An InInA-B Src An In
frequenzaHz
dB
Gu
ad
ag
no
60 200 2800
0dB0dB
-6dB
Esempio di un sistema a 3-vie
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
Out 1 Out 2 Out 3
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Esempio di un sistema a 3-vie
61 62
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
26NAC 26NAC
R TE
DO
R
MO LEU O R CE S
E O TR L A
S O
O C ND I P
P hsuernE t
o su cti nF nel rS e tc o
E CSME UN
IGCHTE OL SN EOBd
ocaL l
M
0
484
467
430
44
31
75
12
7
DIMENSIONI DIMENSIONSABMESSUNGEN DIMENSIONS
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
REAR PANEL CONNECTIONS
1586 75 141210 11 13 169 17
14) USB connectorThis USB connector (type B) allows to connect the processor to a compute to check and update the firmware via a dedicated program (DVA Network)
15) ldquoMAINSrdquo POWER CONNECTIONIt allows to connect the provided power cord
16) FUSE HOLDER ldquoFUSErdquoMain power supply fuse housing
17) ldquoPOWERrdquo MAIN SWITCHThis switch allows to switch on and off the device
PUSH
P SHU
SHPU
P SHU
PUSH
CONNECTIONS
Analog Audio ConnectionsBalanced connections allow to minimize the cable induced noise so cable can be longerSuch connections may be used both on inputs and outputsXLR connector must be cabled with pin 1 to ground pin 2 to hot (+) and pin 3 to cold (-) With shielded cables connect the shield to pin 1XLR-XLR e XLR-Jack 14(63 mm) connection cables can be used to connect the AC26N
12
3
Input
XLR - female
Pin 3 =NegativeCold-VE Phase
Pin 3 =NegativeCold-VE Phase
1 2
3
Output
XLR - Male
Pin 2 = PositiveHot+VE Phase
Pin 2 = PositiveHot+VE Phase
Pin 2 = PositiveHot+VE Phase
Pin 2 = PositiveHot+VE Phase
Pin 1 =ScreenGroundEarth
Pin 1 =ScreenGroundEarth
Pin 1 =ScreenGroundEarth
Pin 1 =ScreenGroundEarth
Ring
Sleeve
Tip = PositiveHot+VE Phase
Ring = NegativeCold-VE Phase
Sleeve=ScreenGroundEarth
Sleeve=ScreenGroundEarth
Tip
The unbalanced connections can also be used However the cable induced noise increases and cable length must not exceed 5 metersSuch connections may be used both on inputs and outputsUnbalanced connection may lower the level of the input signal up to 6dB in order to overcome this drawback connect pin 3 to ground although this can increase the noise
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
18
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
17
CONTROLS AND FUNCTIONS
5) -6dB SELECTORThis selector allows to reduce all the analog XLR [6] input levels by 6 dB at the same time to compensate for the high output levels on the mixers or other audio devices When the input signal level bar on the display [1] remains always at full scale this means that the input signal level is excessive and a -6 dB attenuation is recommendedIn the Option menu it is possible to check when the selector is activated
6) INPUT CONNECTORS ldquoArdquo AND ldquoBrdquoInputs balanced at line levelCapable to accept XLR male connectors
7) OUTPUT CONNECTORS ldquo1rdquo ldquo2rdquordquo 3rdquo ldquo4rdquo ldquo5rdquo AND ldquo6rdquoOutputs balanced at line level Capable to accept XLR famale connectors
Be careful to correctly connect each output to each speaker or amplifier according to the settings of each channels to avoid damages and malfunctions
ldquoAESEBUrdquo Section
8) INPUT CONNECTORIn addition to the analog audio inputs a SPDIF-AESEBU (AES3) digital audio input is also provided It can be selected via the setup menuSuch input requires a balanced connection trough an XLR connector with a 110 ohm twisted 3-wires cable
9) ldquoOUTrdquo OUTPUT CONNECTORThis connector allows to forward audio signals available at the digital or analog inputs or outputs The source must be set by means of the Option menuThe connection must comply with the same standard of the input [8]
RDNET Section
10) DATA INPUT CONNECTORData input RJ45 connector
11) ldquoDATA LINKrdquo OUTPUT CONNECTORRJ45 connector for data output used for serial link in cascade
12) ldquoONrdquo INDICATOR LIGHTThis green indicator turns on only when the AC26N has recognized the RDNET main unit and it is connected to it via computer
13) ldquoACTIVErdquo INDICATOR LIGHTThis yellow indicator flashes when data transmission between RDNET and the device is active
12
3
Input
XLR - female
1 2
3
Output
XLR - Male
Tip Gambo
Tip= Signal
Pin 3 = Link to Pin 1
Pin 3 = Link to Pin 1
Digital Audio Connections (AESEBU)AESEBU (AES3 protocol) is and a balanced input electrically insulated by means of a transformer It allows carrying two audio channels in a single two-wires shielded cable The cable characteristics are twisted 3 poles impedance 100 ohm shielded equipped with XLR connector (AES3 standard)
RDnetEach RDNet port on Control 2 and Control 8 can be connected to maximum 32 cascade-connected compatible devices In the example below the control unit RDNET CONTROL 2 port is connected to the DATA INPUT of an AC 26N whose parallel DATA LINK output is sent to the input of the next AC26N In the example [n] is a number between 3 and 32 (maximum limit for the devices connected to a sub-network)
RJ 45
|1|2|3|4|5|6|7|8|
The overall length of a CAT5 sub-network cable cannot exceed 900 meters
The connector must be connected as follows
1 - Available for other functions (for example audio +) 2 - Available for other functions (for example audio -)3 - Available for other functions (for example analog ground)4 - digital ground5 - digital ground6 - Available for other functions (for example power supply)7 - RS 485 A8 - RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
POWER ON
When the device is turned on the initialization procedure starts It lasts few seconds The display shows the device model the company logo and a program loading progress bar
At the end of the installation process the display shows the Meters menu For further details about the indications refer to the paragraph MENU DESCRIPTION - METERS
AC26N is now ready for use
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION AND DISPLAY
To access the main menu window press the MENU key located on the device front panelIn any page of the menu press the ESC button to return to the previous screen
MAIN MENU
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
There are six menus in the processor They show andor configure the system parametersThe main menus are
Meters Input and output levels display program in progress display quick muting
Preset Store save and delete the system configurations
Matrix Select the outputs according to the input signal
Ch Job Configuration of each individual channel
X-Over Configuration of the cut-off frequency and the types of filters for each output
Option Assignment of the inputs and outputs display contrast firmware version inputs and other options
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
20
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
19
The menus and the individual options displayed can be selected by rotating the knob ldquoFUNCTION SELECTORrdquo ( ) To access the selection highlight the desired parameter and press the ldquoPush Enterrdquo ( | ) knobThe same procedure should be adoptd to select andor change the options inside each menu entry
MENU DESCRIPTION - ldquoMetersrdquo
This window allows to view the configuration and the general conditions of the inputs and outputs the version of the program used the program status and how the system is driven
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) INPUT AND OUTPUT CHANNELSThe input and output connectors are identified by the same information provided on the screen printing located on the device rear sideWith digital input signals the indications A and B concern the inputBy rotating the knob FUNCTION SELECTOR [2] input channels output channels and general muting indications are cyclically scrolled (d) the selected channel is highlighted
b) BAR COMPRESSION LEVEL CHANNEL MUTING
SIGNAL COMPRESSIONSignal compression is displayed by the vertical scrolling (top to down) of the right bar
MUTE Each channel can be individually muted Select the channel and press the Push Enter knob [2] to confirm the change of status The indication of the channel will be replaced by the letter M and the bar will be completely highlightedTo restore normal operation repeat the actions described above
c) SIGNAL LEVEL BARThe level indication for each channel is provided by scrolling the left bar
d) GENERAL MUTINGIt is possible to mute all the inputs and outputs simultaneously Rotate the knob FUNCTION SELECTOR select the letter M and press the Push Enter knobTo restore normal operation repeat the actions described aboveThe general mute has the highest priority with respect to the muting of individual channels
e) CONTROL MODEIt shows how the AC26N is used andor to which devices it is connected
Local = stand-alone usage No connection to an external device
NET = directly connected to dedicated RDnet network and to computer
USB = directly connected to another computer via USB cable
f) SETTING STATUS INDICATIONThis indication shows if the loaded program was amended in one or more parameters with respect to the last saving operation
= original program
= program with modified parameters
g) SET PROGRAMThe number shows the program that is loaded and used by the system with reference to the saving position Refer to the ldquoPresetrdquo menu for further details
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
MENU DESCRIPTION - CH JOB
This window allows to view the configuration of each individual channel
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) INPUT AND OUTPUT CHANNELSThe input and output connectors are identified by the same information provided on the screen printing located on the device rear side
b) SIGNAL LEVELIt shows the signal gain The increased signal intensity is expressed in decibels (dB) Such parameter can be selected in the range from -8000 dB to +2000 dB in steps of 001 dB An increase of 6 dB is approximately equal to doubling - in a linear scale - the signal voltage levelIf the gain exceeds 0 dB the signal is amplified while if the gain is lower than 0 dB the signal is attenuated
c) SIGNAL DELAYThe reproduced audio signal may be delayed to perform an acoustic alignment This compensates for the different positions of the speakers during the installation and the sound reproduction it is expressed in ms The parameter can be selected in the range from 00 ms to 729 ms in steps of 01 msThe following formula can be used to align an audio signal
Delay = (GAPx1000)344
Delay = ms (in milliseconds)GAP = distance between speaker and reference point (in meters)Speed of sound = 344 ms
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
22
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
21
d) MUTEEach channel can be individually muted The same command can be activated in the Meters Menu
NOTE The general mute has the highest priority with respect to the muting of individual channels
e) PhaseIt performs a phase rotation of 180deg with respect to the input signalSuch phase rotation allows the optimization in special way for low frequencies in complex installations
M M
f) EQUALIZATIONThis control opens the menu controlling the single channel equalization It is mainly used to correct one or more frequencies that must be reduced or increased
The AC26N manages 12 filters for each individual channel input and output with three different kinds of configuration
- PEQ Equaliser (peaking equalizer) ideal to identify isolate and correct only a certain range of frequencies All frequencies pass only those around the centre frequency are increased and decreased for a given bandwidth and set gain
- High-shelf Equalizer All frequencies pass but frequencies above the selected cut-off frequency are increased or attenuated by the given gain
- Low-shelf Equalizer All frequencies pass but frequencies below the selected cut-off frequency are increased or attenuated by the given gain
f Numbering of the 12 available filters for the specific input or output1
f Displays the kind of filter2
Dis Switched off (not present)
PEQ Peaking equlizer
Sh H High-shelf Filter
Sh L Low-shelf Filter
Examples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
NOTE
The parameter Bw defines the range of frequencies close to the set frequency where the filter is activated the greater the value of Bw the wider is the frequencies range (1 Bw = 1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONThis control opens the menu controlling the compression for the single channel
g1) ThresholdIdentifies the starting threshold for the compression ratio Base value 11
g2) RatioIndicates the conversion ratio between input and output signal
g3) Post Gain Attach Release HoldThese data are in function of the conversion ratio to achieve Post Gain is the output gain Attack is the attack time Release is the release time Hold is the holding time
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
24
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
23
MENU DESCRIPTION - PRESET
This window allows to store up to 32 configurations in the AC26NThe manufacturer provides the system with a program set and saved in position 0 that is not possible to overwrite
032 Indicates the location where the configuration is savedThis number also appears in the window Meters in position (g) The program in use can be displayed at any time by the user
Empty Preset It is the name associated with the location number when no setting is saved (empty)
Local preset It is the name associated with the location number when a setting is saved NOTE = It is possible to save a setting with the desired name up to 16 letters only via the computer interface
When a program is selected the following window is displayed
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
The name of the assigned program is displayed3 possible choices are available when working on the application
Save The program is saved in the AC 26N memory
Del The program is deleted
Load The program is loaded and ready to be used
MENU DESCRIPTION - X-OVER
This window allows to select for each output a low pass filter a high pass filter or create a band-pass filter via the combination of bothThe available filter is a Linkwitz-Riley where it is possible to select slopes of 12 dBoct 24 dBoct or 48 dBoct and their cut-off frequency
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) OUTPUT CHANNELS
The output connectors are identified by the same information provided on the screen printing located on the device rear side
b) CROSSOVER FILTERSelect the filter according to needs It is possible to select
Dis No filter enabled
HP High-pass filter set it to allow only the part of audio signal above the cut-off frequency
LP Low-pass filter set to allow only the part of audio signal below the cut-off frequency
Filter configuration Low-pass High-pass
Nothing Dis Dis
High-pass HP Dis
Low-pass Dis LP
Band-pass HP LP
12dBoct
24dBoct
Hz
dB
48dBoct
12dBoct
24dBoct
frequency
frequency
frequency
frequency
Hz
dB
48dBoct
c) ATTENUATION SLOPESelect the attenuation slope of the audio signal on the basis of the desired attenuation The higher the attenuation slope at the same cut-off frequency the greater the signal selection It is possible to select
12 equal to 12 dBoct
24 equal to 24 dBoct
48 equal to 48 dBoct
d) CUT-OFF FREQUENCYTo set the passing frequency for the lower frequencies only (low-pass filter) or the higher frequencies only (high-pass filter)The choice of the cut-off depends on the desired sound reproductionThe unit of measurement used is Hz
Hz
Hz
dB
dB
Ga
inG
ain
Ga
inG
ain
f0
f0
0dB0dB
0dB
-6dB
-6dB
0dB
0dB
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
26
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
25
MENU DESCRIPTION - MATRIX
For each output it allows to select the input signal to use as the source
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) OUTPUT CHANNELSIdentification of the output channel to set
b) IDENTIFICATIONS OF THE INPUTSIt selects the type of signal to match each output as needed It is possible to select
In A Associated with the input signal ldquoArdquo
In B Associated with the input signal ldquoBrdquo
In A+B Associated with the algebraic sum of the two input signals ldquoArdquo and ldquoBrdquo
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
MENU DESCRIPTION - OPTION
Allows to display the system settings such as the allocation of the inputs and outputs attenuation display contrast and firmware version
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcThis option allows to set the type of input audio signal
An In = Analog audio signals (inputs A and B)
DigIn = Digital audio signals (AESEBU input)
DigOut SrcThis option allows to select the audio source that will be forwarded to the connector AESEBU OUT (digital output)
An In = Audio signals available at analog inputs
Dig In = Audio signals available at digital inputs
OUT 1-2 = Audio signals available on outputs 1 and 2
OUT 3-4 = Audio signals available on outputs 3 and 4
OUT 5-6 = Audio signals available on outputs 5 and 6
Input ModeIt allows to configure the inputs
Indip = They are independent not subject to constraints of any kind between them
Linked = They are connected and work in stereo mode Compressors filters delays volume are identical for the two channels
Atten PadIt shows how to set the -6 dB switch located on the rear side [Ref 5] It is necessary to activate this selector when the analog input levels are too high The selector can be activated only by means of the button the menu is for display only
0 dB = Selector not activated The input signals are the same as the input source
-6 dB = Selector activated The input signals are attenuated by -6 dB with reference to the inner
processor
ContrastAllows to adjust the LCD display contrast to compensate for the brightness difference at the installation sites Greater display brightness allows to navigate correctly and quickly within the menuThe manufacturer output setting is 60
10 More bright 60 More dark 100
Fw VersIt shows the processor firmware version
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
28
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
27
TECHINICAL SPECIFICATION
AUDIO PERFORMANCEFrequency Response +- 01dB (20 to 30kHz)Dynamic Range 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistortion 0002 (1kHz +4dBu)
DIGITAL AUDIO PERFORMANCE Processor DSP 2856-bit Data processing Frequency 24-bit BURR BROWNAnalog converters 24-bit BURR BROWNPropagation Delay 15msStoring configurations 32 preset
CONTROLS Display LCD graficoButtonsControls ESC - MENU - FUNCTIONS SELECTION
ENTERINPUTSOUTPUTSAnalog Input ndeg2 x XLR (3 pole female)
Input impedance gt10KOhmMaximum Level +21dBu senza PAD
+27dBu con PADAnalog Output ndeg6 x XLR (3 pole male)
Output impedance 50OhmMaximum Level +21dBu Type Balanced
Digital Input ndeg1x XLR (3 pole female)Type SPDIF-AESEBU (AES3)
Digital Output ndeg1x XLR (3 pole male)Type Compliant with the input standard
RDnet InputsOutput ndeg2 x XLR RJ45 (CAT 5 cable)USB Tipo B
SOUND CONTROL PARAMETERSGain -80dB a +20dB step 01dBDelay
Input 0 a 729mS step 01 mSOutput 0 a 340mS step 01mSPhase Rotation 0deg - 180deg
COMPRESSIONThreshold -80dB a +20dB step 01dBRatio 11 a Inf1 step 001Output gain 0dB a 40dB step 01dBAttack time 1mS a 1000mS step 01mSRelease time 1mS a 1000mS step 01mSHold time 1mS a 1000mS step 01mS
EQUALIZERS12 equalizers for each input and outputType PEQ (parametrico) Hi-shelf Lo-sheft
Frequency 20Hz a 20KHz step 1HzGain -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (only with PEQ)
CROSSOVER FILTERSFilter Linkwitz Riley
Type HP High-pass LP Low-pass
Slope 12dBoct - 24dBoct - 48dBoctCUT-OFF FREQUENCY 5Hz a 20KHz passo 1Hz
POWER SUPPLY Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)
1719x17x51 inch (WxHxD)WEIGHT 19Kg
(42 lbs)Note Specifications subject to change without notice
EMI CLASSIFICATIONAccording to the standards EN 55103 this equipment is designed and suitable to operate in E3 (or lower E2 E1) Electromagnetic environments
EINLEITUNG
Verpackungsinhalt
Eigenschaften
AC26N ist ein digitaler Audio-Prozessor fuumlr die Verwaltung von Audio-Systemen der fuumlr feste und mobile Installationen entwickelt wurde AC26N benutzt die modernste Technologie mit 2856 bit-Prozessoren und 24-bit-ADDA-Wandlern mit hoher Leistungsfaumlhigkeit Die verfuumlgbaren Funktionen des Prozessors sind Ein- und Ausgangsstufen Verzoumlgerung (delay) Polaritaumlt 12 Equalizer-Frequenzen fuumlr Ein- und Ausgangskanal viele Crossover-Wahlmoumlglichkeiten und Limiter mit hoher Leistung Die Filter-Kontrolle hat eine Aufloumlsung von 1 Hz Die Ein- und Ausgaumlnge koumlnnen mit unterschiedlichen Einstellungen geregelt werden um allen Anforderungen gerecht zu werden AC26N kann in Echtzeit kontrolliert werden und jeder Parameter kann am Frontpaneel und vom Computer mit intuitiver graphischer Schnittstelle mittels Software DVA Network zugaumlnglich und einer Netzverbindung RDnet oder uumlber USB eingestellt werdenDie SW-Aktualisierung fuumlr CPU und DSP uumlber PC erlaubt die Vorrichtung auf dem aktuellen Stand zu halten Man kann 32 vorgesehene Konfigurationen speichern und aufrufen
- AC26N - Bedienungsanleitung- Software-CD- Versorgungskabel
- 2 Ein- und 6 Ausgaumlnge mit flexibler Adressierung- Adressierbarer Stereo-Ein- und Ausgang AESEBU - DSP 2856-bit- AD-Wandler BURR BROWN 24-bit mit hoher Leistungsfaumlhigkeit- Aufloumlsungsfrequenz der Filter 1 Hz - 12 parametrische Equalizer fuumlr jeden Ein- und Ausgang- 2 Crossover-Filter fuumlr jeden Ausgang mit auswaumlhlbarer Neigung 122448dBoct- DRC Multikonfiguration mit hoher Leistungsfaumlhigkeit fuumlr die Konfiguration des
Limitersder Kompression jedes Ein- und Ausgangs- Einstellbare dB-Stufe Polaritaumlt und Verzoumlgerung (delay) fuumlr jeden Ein- und Ausgang- Firmware-Aktualisierung uumlber PC- Graphisches LCD-Display- 32 Voreinstellungen vom Benutzer einstellbar- USB-Schnittstelle fuumlr die Kontrolle und Konfiguration mit dem Computer- Schnittstelle RDnet welche erlaubt bis zu 256 fern liegende Vorrichtungen
zu kontrollieren
PC
PC
RDNET control(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FUNKTIONEN VORDERSEITE
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
BEDIENUNGEN UND FUNKTIONEN
1) DISPLAYDas graphische LCD-Display erlaubt die Informationen des AC26N ohne einen Computer zu benutzen anzuzeigen und zu editieren Der Kontrast kann im Hauptmenuuml eingestellt werden
2) DREHGRIFF Functions Selector UND Push EnterDiese Kontrolle erlaubt sich in den Menuumls auf dem Display zu bewegen und die Parameter auszuwaumlhlen und zu veraumlndernDrehung des Drehgriffes (Functions Selectors)- Man kann sich innerhalb der verschiedenen Menuumlseiten bewegen- Erlaubt die Veraumlnderung der ausgewaumlhlten ParameterDruck des Drehgriffes (Push Enter)- Erlaubt die AuswahlBestaumltigung der Parameter
3) Taste ldquoESCrdquo Diese Kontrolle erlaubt die angezeigten Menuumls zu verlassen oder zur vorherigen Anzeige zuruumlckzukehren
4) Taste ldquoMenuumlrdquo Diese Kontrolle erlaubt den direkten Zugang zum Hauptmenuuml
Deuts
chD
euts
chB
ed
ien
un
gsan
leit
un
gB
ed
ien
un
gsan
leit
un
g
29
Deuts
chD
euts
chB
ed
ien
un
gsan
leit
un
gB
ed
ien
un
gsan
leit
un
g
30
DVA USB Manager
Die Firmware des Verstaumlrkermoduls kann uumlber den USB-Anschluss aktualisiert werdenUm diesen Vorgang zu ermoumlglichen und zu vereinfachen wurde ein dediziertes Programm entwickelt das beim Hersteller angefordert und auf einen Computer installiert werden muss
Wir empfehlen die Software DVA USB Manager direkt von der Webseite dB Technologies (wwwdbtechnologiescom) im Abschnitt laquoSoftware amp Controllerraquo herunterzuladen
DVA Network
AC26N ist mit einer eigenen als RDNET bezeichneten Netzschnittstelle ausgestattet dank der es uumlber ein Interface (RDNET Control) an einen Computer angeschlossen werden koumlnnenHierzu wurde ein Kommunikationsprotokoll entwickelt mit dem die Daten empfangen und gesendet werden Dank dieser Verbindung koumlnnen die Lautsprecherparameter wie Ausgangsleistung Verstaumlrkertemperatur Limiterstatus usw in Echtzeit kontrolliert werden Auszligerdem koumlnnen verschiedene Entzerrungen ausgewaumlhlt bzw neue erstellt werden oder die gewuumlnschte Lautstaumlrke eingestellt werden
Wir empfehlen die Software DVA_Network direkt von der Webseite dB Technologies (wwwdbtechnologiescom) im Abschnitt laquoSoftware amp Controllerraquo herunterzuladenDOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
RUumlCKWANDANSCHLUumlSSE
1586 75 141210 11 13 169 17
14) USB-SteckverbinderDieser USB-Steckverbinder (Typ B) erlaubt den Prozessor an einem Computer anzuschlieszligen um die Firmware mit dem speziellen Programm (DVA Network) zu kontrollieren und zu aktualisieren
15) STROMANSCHLUSS MAINSErlaubt den Anschluss des mitgelieferten Versorgungskabels
16) SICHERUNGSTRAumlGER FUSEAufnahme fuumlr die Netz-Sicherung
17) HAUPTSCHALTER POWERDer Schalter erlaubt das Aus- und Einschalten des Audio-Controllers
BEDIENUNGEN UND FUNKTIONEN
5) WAHLSCHALTER -6dBDer Wahlschalter erlaubt das Level des analogen Eingangs XLR [6] um 6 dB zu verringern und gleichzeitig das hohe Ausgangslevel der Mixer oder anderer Audio-Vorrichtungen auszugleichen Wenn der Balken des Signallevels der Eingaumlnge auf dem Display [1] immer auf Maximum steht zeigt dies an dass das Signallevel am Eingang hoch ist und es wird empfohlen die Daumlmpfung -6dB zu benutzenIm Menuuml Option ist es moumlglich zu kontrollieren ob der Wahlschalter aktiviert ist
6) STECKVERBINDER AM EINGANG A UND BAuf Leitungslinie ausgeglichene EingaumlngeSie koumlnnen auch XLR-Steckdosen aufnehmen
7) AUSGANG-STECKVERBINDER ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo UND ldquo6rdquoAuf Leitungslinie ausgeglichene Ausgaumlnge Sie koumlnnen auch XLR-Stecker aufnehmen
Darauf achten dass die Ausgaumlnge korrekt entsprechend der Einstellungen der einzelnen Kanaumlle an den Lautsprechern oder Verstaumlrkern angeschlossen sind um Schaumlden und Fehlfunktionen vorzubeugen
Abschnitt ldquoAESEBUrdquo
8) EINGANGS-STECKVERBINDER INZusaumltzlich zu den analogen Audio-Eingaumlngen wurde ein digitaler Audio-Eingang SPDIF-AESEBU (AES3) vorgesehen der uumlber das Setup-Menuuml ausgewaumlhlt werden kannDer Eingang erfordert einen ausgeglichenen Anschluss mit einem XLR-Steckverbinder mit einem verdrillten Kabel mit 3 Leitern von 110 Ohm
9) AUSGANGS-STECKVERBINDER OUTDieser Steckverbinder erlaubt das Audiosignal an den analogen oder digitalen Eingaumlngen oder Ausgaumlngen zu verteilen Die Quelle muss uumlber das Menuuml Option eingestellt werdenDer Anschluss muss demselben Standard des Eingang entsprechen [Ref 8]
Abschnitt ldquoRDNETrdquo
10) EINGANGS-STECKVERBINDER DATA INPUTSteckverbinder RJ45 fuumlr den Dateneingang
11) AUSGANGS-STECKVERBINDER DATA LINKSteckverbinder RJ45 fuumlr den Datenausgang Fuumlr die serielle Kaskaden-Verbindung
12) LEUCHTANZEIGE ONDiese gruumlne Anzeige leuchtet nur wenn AC26N uumlber den Computer mit der Haupteinheit RDNET verbunden ist und diese erkannt hat
13) LEUCHTANZEIGE ACTIVEDiese gelbe Anzeige blinkt wenn eine Datenuumlbertragung zwischen RDNET und der Vorrichtung aktiv ist
PUSH
P SHU
SHPU
P SHU
PUSH
ANSCHLUumlSSE
Analoge Audio-AnschluumlsseDie ausgeglichenen Anschluumlsse erlauben die Geraumlusche der Kabel auf ein Minimum zu verringern und so die Benutzung langer Kabel zuzulassenDiese Anschluumlsse koumlnnen sowohl an den Ein- als auch an den Ausgaumlngen benutzt werdenDer XLR-Steckverbinder muss mit Pin 1 an Masse Pin 2 am Pluspol (+) und Pin 3 am Minuspol (-) angeschlossen werden Bei einem abgeschirmten Kabel muss die Abschirmung an Pin 1 liegenDie Verbindungskabel XLR-XLR und XLR-Jack 14 (63 mm) koumlnnen fuumlr den Anschluss
12
3
Eingang
XLR weiblichen
Pin 3 = MinuspolErkaumlltungphase -VE
Pin 3 = MinuspolErkaumlltungphase -VE
1 2
3
Ausgang
XLR maumlnnlichen
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Ring
Schaft
Spitze = PluspolWaumlrmephase +VE
Ring = MinuspolErkaumlltungphase -VE
Schaft=SchirmMasse
Spitze
Die nicht ausgeglichenen Anschluumlsse koumlnnen auch benutzt werden wenn die Kabelgeraumlusche ansteigen und diese Kabel duumlrfen nicht laumlnger sein als 5 MeterDiese Anschluumlsse koumlnnen sowohl an den Ein- als auch an den Ausgaumlngen benutzt werdenDie nicht ausgeglichenen Anschluumlsse koumlnnen das Signallevel am Eingang um 6 dB verringern um dem vorzubeugen muss Pin 3 an Masse angeschlossen werden obwohl dies das Geraumlusch verstaumlrken kann
12
3
Eingang
XLR weiblichen
1 2
3
Ausgang
XLR maumlnnlichen
Spitze Schaft
Spitze = Signal
Schaft=SchirmMasse
Pin 3 = zu Pin 1 gebruumlckt
Pin 3 = zu Pin 1 gebruumlckt
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
31
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
32
Digitales Audio (AESEBU)AESEBU (Protokoll AES3) ist ein ausgeglichener und uumlber einen Transformator elektrisch isolierter Eingang Er erlaubt die Benutzung von zwei Kanaumllen an einem einzigen abgeschirmten bipolaren Kabel Das gedrillte Kabel muss 3-polig sein eine Impedanz von 100 Ohm haben und mit einem XLR-Steckverbinder (AES3 Standard) abgeschirmt sein
RdnetJeder Port RDNet an Control 2 und Control 8 kann an max 32 kompatiblen Vorrichtungen die in Kaskade geschaltet sind angeschlossen werden Im nachstehenden Beispiel ist der Port der Kontrolleinheit RDNET CONTROL 2 am Eingang DATA INPUT eines AC 26N angeschlossen dessen paralleler Ausgang DATA LINK zum Eingang des naumlchsten AC26N geht Im Beispiel ist [n] eine Nummer zwischen 3 und 32 (maximale Anzahl der anschlieszligbaren Vorrichtungen an nur einem Netz)
RJ 45
|1|2|3|4|5|6|7|8|
Die Gesamtlaumlnge des Kabels CAT5 eines Unternetzes kann NICHT laumlnger als 900 Meter sein
Der Steckverbinder muss wie folgt angeschlossen sein1 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio +) 2 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio -)3 ndash Verfuumlgbar fuumlr andere Funktionen (zB analoge Masse)4 ndash digitale Masse5 ndash digitale Masse6 ndash Verfuumlgbar fuumlr andere Funktionen (zB Versorgung)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
EINSCHALTEN
Beim Einschalten der Vorrichtung startet die Initialisierung die einige Sekunden lang dauert Auf dem Display wird das Modell das Logo und der Fortschrittsbalken der Ladung des Programms angezeigt
Nach der Initialisierung erscheint auf dem Display das Menuumlfenster Meters Um die Angaben im Detail zu erfahren beziehen Sie sich bitte auf das Kapitel BESCHREIBUNG DES MENUumlFENSTERS Meters
AC26N kann jetzt benutzt werden
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
MENUrsquo PRINCIPALE
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Die sechs Menuumls im Prozessor zeigen undoder konfigurieren die Systemparameter
Anzeige der Levels der Ein- und Ausgaumlnge Anzeige des benutzten Programms und dessen Status Mute schnell
Speicherung Speicherung und Eliminierung der Systemkonfigurationen
Auswahl der Ausgaumlnge je nach Eingangssignal
Konfiguration jedes einzelnen Kanals
Konfiguration der Schnittfrequenzen und der Filtertypen fuumlr jeden einzelnen Ausgang
Zuordnung der Ein- und Ausgaumlnge Kontrast des Displays Firmware-Version Eingaumlnge und andere Optionen
Das Menuuml und die einzelnen Optionen der Anzeige koumlnnen durch Drehen des Drehgriffes FUNKTIONS SELECTOR ( ) ausgewaumlhlt werden
Die Hauptmenuumls sind
Meters
Preset
Matrix
Ch Job
X-Over
Option
Um die Auswahl zu treffen muss der gewuumlnschte Parameter auswaumlhlt und der Drehgriff Push Enter( | ) gedruumlckt werdenDas selbe Verfahren muss fuumlr die Auswahl undoder die Aumlnderung der Optionen innerhalb der Menuumlpunkte angewendet werden
BESCHREIBUNG DES MENUumlFENSTERS Meters
Diese Seite erlaubt die Konfigurationen und den allgemeinen Status der Ein- und Ausgaumlnge der benutzten Programmversion dessen Status und die Steuerung des Systems anzuzeigen
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
KONFIGURATION UND ANZEIGE
Um in das Fenster des Hauptmenuumls zu gelangen muss die Taste Menuuml ( ) auf der Frontseite der Vorrichtung gedruumlckt werdenMit der Taste ESC ( ) kehrt man von jeder Seite des Menuumls auf die vorherige Seite zuruumlck
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
33
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
34
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziertBei den digitalen Eingangssignalen entspricht die Angabe A und B dem EingangDreht man den Drehgriff FUNCTIONS SELECTOR [2] durchlaumluft man zyklisch die Ein- und Ausgangskanaumlle und die Angabe Mute allgemein (d) der ausgewaumlhlte Kanal wird hervorgehoben
b) BALKEN FUumlR DAS KOMPRESIONSLEVELMUTE KANAL
SIGNALKOMPRESSIONDie Signalkompression wird durch das Gleiten des rechten Balkens von oben nach unten angezeigt
MUTE Jeder einzelne Kanal kann auf Mute gestellt werden Den Kanal auswaumlhlen und den Drehgriff Push Enter [2] druumlcken um die Aumlnderung des Status zu bestaumltigen Die Angabe des Kanals wird durch den Buchstaben M ersetzt und der Balken wird komplett hervorgehobenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werden
c) BALKEN DES SIGNALLEVELSDie Anzeige des Levels jedes einzelnen Kanals wird durch das Gleiten des linken Balkens angezeigt
d) MUTE ALLGEMEINEs ist moumlglich alle Ein- und Ausgaumlnge gleichzeitig auf Mute zu schalten Den Drehgriff FUNCTIONS SELECTOR drehen den Buchstaben M waumlhlen und dann den Drehgriff Push Enter druumlckenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werdenDie allgemeine Stummschaltung hat eine houmlhere Prioritaumlt als die Stummschaltung der einzelnen Kanaumlle
e) ANSTEUERUNGSARTENEs wird angezeigt wie AC26N benutzt wird undoder an welchen Vorrichtungen es angeschlossen ist
= Benutzung stand-alone Kein Anschluss an einer externen Vorrichtung
= Direkt am Netz RDnet und am Computer angeschlossen
= Uumlber USB-Kabel direkt am Computer angeschlossen
f) ANZEIGE DES STATUS DER EINSTELLUNGENHier wird angezeigt ob einer oder mehrere Parameter des geladenen Programms im Vergleich zur letzten Speicherung veraumlndert wurden
Original-Programm
Programm mit veraumlnderten Parametern
g) EINGESTELLTES PROGRAMMDie Nummer zeigt das vom System geladene und benutzte Programm in Bezug auf die Lokalisierung der Speicherung an Fuumlr weitere Details beziehen Sie sich bitte auf das Menuuml Preset
Local
NET
USB
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
BESCHREIBUNG DES MENUumlFENSTERS Ch Job
Dieses Fenster erlaubt die Anzeige der Konfiguration jedes einzelnen Kanals
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) SIGNALLEVELZeigt die Signalstaumlrke an Das Ansteigen der Signalintensitaumlt wird in Dezibel (dB) ausgedruumlckt Der Parameter kann zwischen -8000 dB und +2000 dB in Schritten von 001 dB ausgewaumlhlt werden Ein Anstieg von 6 dB ist fast gleich eine Verdoppelung in linearer Skala des Spannungswertes des SignalsBei einer Staumlrke von 0 dB wird das Signal verstaumlrkt waumlhrend es ein einer Staumlrke von weniger als 0 dB abgeschwaumlcht wird
c) VERZOumlGERUNG DES SIGNALS (DELAY)Das wiedergegebene Audio-Signal kann verzoumlgert werden um die akustische Ausrichtung zu erlauben Dies gleicht die verschiedenen Positionen der Lautsprecher bei der Installation und Klangwiedergabe aus und wird in mS ausgedruumlckt Der Parameter kann zwischen 00 mS und 729 mS in Schritten von 01mS ausgewaumlhlt werden
Um ein Audiosignal auszurichten kann folgende Formel benutzt werden
Verzoumlgerung = GAPx1000)344
Verzoumlgerung = mS (in Millisekunden ausgedruumlckt)GAP = Abstand des Lautsprechers vom Referenzpunkt (in Metern ausgedruumlckt)Klanggeschwindigkeit = 344 ms
d) MUTEJeder einzelne Kanal kann auf Mute gestellt werden Derselbe Befehl kann im Fenster des Menuumls Meters aktiviert werden PS Die al lgemeine Stummschaltung hat eine houmlhere Priori taumlt als die Stummschaltung der einzelnen Kanaumlle
e) PHASEErlaubt die Phasenrotation um 180deg zum EingangssignalDiese Rotation erlaubt vor Allem die Optimierung der niederen Frequenzen bei komplexen Installationen
f) ENTZERRUNGENDieser Befehl oumlffnet das Menuumlfenster fuumlr die Entzerrung des einzelnen Kanals Er wird vor Allem benutzt um eine oder mehrere Frequenzen zu korrigieren die gedaumlmpft oder verstaumlrkt werden muumlssen
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
35
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
36
AC26N verwaltet 12 Filter fuumlr jeden einzelnen Ein- und Ausgangskanal mit drei verschiedenen Konfigurationen- Equalizer PEQ (peaking equalizer) ist ideal um nur ein bestimmtes Frequenzband
zu identifizieren zu isolieren und zu korrigieren Es gehen alle Frequenzen durch aber nur die um die mittlere Frequenz steigt und sinkt um eine bestimmte Bandbreite und eine bestimmte Staumlrke
- Equalizer High-Shelf geht alle Frequenzen durch aber die Frequenzen uumlber der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
- Equalizer Low-Shelf geht alle Frequenzen durch aber die Frequenzen unter der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
f Nummerierung der 12 verfuumlgbaren Filter fuumlr diesen Ein- oder Ausgang1
f2 Es wird der Filtertyp angezeigt
Dis Ausgeschaltet (nicht vorhanden)
PEQ Peaking equalizer
Sh H Filter High-Shelf
Sh L Filter Low-shelf
Beispiele PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
ANMERKUNGDer Parameter Bw legt das Frequenzfeld neben der eingestellten Frequenz fest wo der Filter aktiviert wird je houmlher der Bw-Wert desto houmlher das Frequenzfeld (1Bw=1 Oktave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filter High-Shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filter Low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) KOMPRESSIONDieser Befehl oumlffnet das Menuumlfenster fuumlr die Kompression des einzelnen Kanals
g1) TresholdIdentifiziert die Schwelle an der das Kompressionsverhaumlltnis beginnt Der Basiswert 11
g2) RatioIdentifiziert das Kompressionsverhaumlltnis zwischen dem Ein- und Ausgangssignal
g3) Post Gain Attach Release HoldDiese Daten entsprechen dem Kompressionsverhaumlltnis das man erreichen moumlchte
Post Gain ist der Gewinn am AusgangAttack ist die Anschlusszeit Release ist die ReleasezeitHold ist die Beibehaltungszeit
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
BESCHREIBUNG DES MENUumlFENSTERS Preset
Dieses Fenster erlaubt bis zu 32 Konfigurationen im AC26N zu speichernDer Hersteller liefert das System mit einem voreingestellten Programm das auf Position 0 gespeichert ist und nicht uumlberschrieben werden kann
032 Es zeigt die Lokalisierung der Speicherung der KonfigurationDiese Nummer erscheint auch im Fenster Meters auf der Position (g) Das benutzte Programm kann jederzeit vom Benutzer angezeigt werden
Empty Preset Es ist der Name der der Nummer der Lokalisierung zugeordnet wird wenn keine Einstellung gespeichert ist (leer)
Local preset Es i s t de r Name de r de r Nummer de r Loka l i s i e rung zugeordnet wird wenn eine Konfiguration gespeichert wird
ANMERKUNG = Man kann eine Einstellung mit dem gewuumlnschten Namen mit max 16 Buchstaben nur speichern wenn man die Schnittstelle uumlber den Computer benutzt
Bei der Wahl eines Programms erscheint folgendes Fenster
Anzeige des Namens der dem Programm zugeordnet istUm auf die Anwendung einzuwirken stehen 3 Auswahlmoumlglichkeiten zur Verfuumlgung
Das Programm wird im Speicher des AC 26N gespeichert
Das Programm wird geloumlscht
Das Programm wird geladen und ist bereit fuumlr die Benutzung
Save
Del
Load
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
37
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
38
BESCHREIBUNG DES MENUumlFENSTERS X-Over
Dieses Fenster erlaubt fuumlr jeden Ausgang einen Bassdurchgangsfilter einen Hochdurchgangsfilter oder mittels Kombination von beiden einen Banduumlbergangsfilter zu waumlhlenDer Filter ist ein Linkwitz-Riley wo man die Neigung von 12 dBoct 24dBoct oder 48 dBoct und die entsprechende Schnittfrequenz auswaumlhlen kann
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) AUSGANGSKANAumlLE
Die Steckverbinder am Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) FILTER CROSSOVERDen Filter nach Bedarf waumlhlen Man kann folgendes auswaumlhlen
Dis Kein Filter aktiviert
HP Hochdurchgangsfilter nur den Teil des Audiosignals durchlassen der uumlber der Schnittfrequenz liegt
LP Bassdurchgangsfilter nur den Teil des Audiosignals durchlassen der unter der Schnittfrequenz liegt
Filter-Konfiguration Tiefpass Hochpass
Nichts Dis Dis
Hochpass HP Dis
Tiefpass Dis LP
Bandpass HP LP
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
c) DAumlMPFUNGSNEIGUNGDie Daumlmpfungsneigung des Audiosignals auf der Basis der Verringerung auswaumlhlen die man erreichen moumlchte Je houmlher die Daumlmpfungsneigung bei gleicher Schnittfrequenz desto groumlszliger ist die Signalauswahl Man kann folgendes waumlhlen
12 entsprechend 12 dboct
24 entsprechend 24 dboct
48 entsprechend 48 dboct
d) SCHNITTFREQUENZErlaubt die Durchgangsfrequenz der niederen Frequenzen (Bassdurchgangsfilter) oder der hohen Frequenzen (Hochdruchgangsfilter) einzustellenDie Auswahl des Schnitts bezieht sich auf die Wiedergabe die man erreichen moumlchteDie benutzte Maszligeinheit ist Hz
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
BESCHREIBUNG DES MENUumlFENSTERS Matrix
Erlaubt fuumlr jeden Ausgang das Eingangssignal zu waumlhlen das als Quelle benutzt werden soll
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) AUSGANGSKANAumlLEIdentifizierung des einzustellenden Ausgangskanals
b) IDENTIFIZIERUNG DER EINGAumlNGEDen Signaltyp auswaumlhlen der nach eigener Anforderung jedem einzelnen Ausgang zugeordnet werden soll Man kann folgendes waumlhlen
In A Das Signal wird dem Eingang A zugeordnet
In B Das Signal wird dem Eingang B zugeordnet
In A+B Zuordnung der a lgebra ischen Summe der be iden Eingangssignale A und B
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
BESCHREIBUNG DES MENUumlFENSTERS Option
Erlaubt die Anzeige der Systemeinstellungen wie die Zuordnung der Ein- und Ausgaumlnge Daumlmpfung Displaykontrast und Firmware-Version
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B Src
Diese Option erlaubt die Einstellung des Audio-Signaltyps am Eingang
Analoge Audiosignale (Eingaumlnge A und B)
Digitale Audiosignale (Eingang AESEBU)
DigOut Src
An In =Audiosignale an den analogen Eingaumlngen
Dig In =Audiosignale am digitalen Eingang
OUT 1-2 =Audiosignale an den Ausgaumlngen 1 und 2
OUT 3-4 =Audiosignale an den Ausgaumlngen 3 und 4
OUT 5-6 =Audiosignale an den Ausgaumlngen 5 und 6
Input Mode
An In
Dig In
Indip =
Linked =
Diese Option erlaubt die Audioquelle zu waumlhlen die fuumlr den Steckverbinder AESEBU OUT (digitaler Ausgang) bestimmt ist
Erlaubt die Eingaumlnge zu konfigurieren
Sie sind unabhaumlngig und selbststaumlndig sie unterliegen keinen Verpflichtungen untereinander Sie sind verbunden und funktionieren im Stereo-Modus
Die Kompressoren Filter Verzoumlgerungen die Lautstaumlrke sind bei beiden Kanaumllen identisch
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
39
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
40
Atten PadZeigt an wie der Wahlschalter -6 dB auf der Ruumlckseite eingestellt ist [Ref 5] Dieser Wahlschalter muss aktiviert werden wenn das Level an den analogen Eingaumlngen zu hoch ist Der Wahlschalter wird uumlber die Taste aktiviert im Menuuml gibt es nur eine Anzeige
0dB = Wahlschalter nicht aktiviert
-6dB = Wahlschalter aktiviert
Contrast
10 heller 60 dunkler 100
Fw Vers
Die Eingangssignale sind dieselben wie die Eingangsquelle
Die Eingangssignale werden vom internen Prozessor um -6 dB gedaumlmpft
Erlaubt den Kontrast des LCD-Displays einzustellen um den Unterschied der Helligkeit auf den Installationsort auszurichten Ein deutlicheres Display erlaubt auf korrekte und schnelle Weise innerhalb der Menuumls zu surfenDie Hersteller-Einstellung am Ausgang liegt bei 60
Zeigt die Firmware-Version des Prozessors an
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
41
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
42
TECHNISCHE DATEN
Antwort in FrequenzDynamische GammaCMMRCrosstalkDistorsion
ProzessorFrequenz der DatenausarbeitungAnaloge Converter Verzoumlgerung der VerteilungSpeicherung der Konfigurationen
DisplayTastenBedienungen
Analoger Eingang ndeg2 x XLR (3-poliger Female Stecker)Impedanz des Eingangs gt10KOhmMaximales Level +21dBu ohne PAD
+27dBu bei PAD
Impedanz des Ausgangs 50OhmMaximales Level +21dBu Typ symmetrisch
Typ SPDIF-AESEBU (AES3)
Typ Entsprechend dem Standard des Eingang
Typ
Typ
NETZSPANNUNGABMESSUNGEN (BXHXT)GEWICHT
AUDIO-LEISTUNGEN+- 01dB (20 to 30kHz)116dB typgt 60dB (50 to 10kHz)lt -100dB0002 (1kHz +4dBu)
DIGITALE AUDIO-LEISTUNGEN DSP 2856-bit 48KHz24-bit BURR BROWN15ms32 preset
KONTROLLEN LCD GrafikESC - MENU - FUNCTIONS SELECTIONENTER
EIN-AUSGAumlNGE
Analoger Ausgang ndeg6 x XLR (3-poliger Male Stecker)
Digitaler Eingang ndeg1x XLR (3-poliger female Stecker)
Digitaler Ausgang ndeg1x XLR (3-poliger Male Stecker)
Ein-Ausgang Rdnet ndeg2 x XLR RJ45 (kabel CAT 5) USB Typ B
KONTROLLPARAMETER AUDIOStaumlrke -80dB a +20dB step 01dBVerzoumlgerung Eingang 0 a 729mS step 01 mS
Ausgang 0 a 340mS step 01mSPhasenrotation 0deg - 180deg
KOMPRESSIONSchwelle -80dB a +20dB step 01dBVerhaumlltnis 11 a Inf1 step 001Staumlrke am Ausgang 0dB a 40dB step 01dBAnschlusszeit 1mS a 1000mS step 01mSReleasezeit 1mS a 1000mS step 01mSBeibehaltungszeit 1mS a 1000mS step 01mS
EQUALIZER12 Equalizer fuumlr jeden Ein- und Ausgang
PEQ (parametrischer) Hi-shelf Lo-sheftFrequenz 20Hz a 20KHz step 1HzStaumlrke -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (lediglich PEQ)
FILTER CROSSOVERFilter Linkwitz Riley
HP HochdurchgangsfilterLP Bassdurchgangsfilter
Neigung 12dBoct - 24dBoct - 48dBoctSchnittfrequenz 5Hz a 20KHz step 1Hz
Full-range 100-240Vac 50-60Hz430482x43x130mm 19Kg
AnmerkungenSpezifikationen unterliegen Aumlnderungen ohne Vorankuumlndigung
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
INTRODUCTIONAC26N est un processeur audio numeacuterique pour la gestion de leacutequipement audio conccedilu pour des installations fixes et mobiles Il fonctionne selon une technologie de pointe avec des processeurs agrave 2856bits et des convertisseurs ADDA agrave 24-bits hautes performances Les fonctions du processeur sont les niveaux dentreacutee et de sortie le deacutelai (delay) la polariteacute 12 bandes deacutegalisation par canal dentreacutee et de sortie diffeacuterentes seacutelections de croisement (crossover) et un limiteur hautes performances Le controcircle des filtres a une reacutesolution de 1Hz Les entreacutees et les sorties peuvent ecirctre programmeacutees en plusieurs configurations pour satisfaire tous les besoins AC26N peut ecirctre controcircleacute en temps reacuteel et tous les paramegravetres peuvent ecirctre configureacutes depuis le pupitre frontale et par ordinateur avec interface graphique intuitive accessible via le logiciel laquoDVA Networkraquo et une connexion de reacuteseau deacutedieacutee RDnet ou USBLa mise agrave jour du logiciel pour lUniteacute centrale et DSP par ordinateur portable permet de maintenir le dispositif actualiseacute Il est possible denregistrer et de rappeler 32 configurations preacute-eacutequipeacutees de configuration
Contenu de lemballage - AC26N - Mode demploi- CD logiciel- Cacircble dalimentation
Caracteacuteristiques- 2 entreacutees et 6 sorties avec adressage flexible- Entreacutee et sortie steacutereacuteo AESEBU adressables - DSP 2856-bit- Convertisseurs AD BURR BWOWN 24-bit hautes performances- Freacutequence de reacutesolution des filtres 1 Hz - 12 eacutegaliseurs parameacutetriques pour chaque entreacutee et sortie- 2 filtres de croisement par sortie avec pente seacutelectionnable agrave 122448dBoct- DRC agrave configuration multiple hautes performances pour configuration limiteur
compression pour chaque entreacutee et sortie- Niveau reacuteglable en dB polariteacute et deacutelai pour chaque entreacutee et sortie- Mise agrave jour du micrologiciel par lordinateur- Affichage graphique agrave cristaux liquides- 32 preacutereacuteglages enregistrables par lutilisateur- Interface USB pour le controcircle et la configuration par ordinateur- Interface RDnet permettant de controcircler jusquagrave 256 dispositifs agrave distance
PC
PC
RDNETcontrol(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FONCTIONS DE LA FACE AVANT
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
COMMANDES ET FONCTIONS1) AFFICHAGE
Laffichage graphique agrave cristaux liquides permet de visualiser et deacutediter les informations de lAC26N sans utiliser lordinateur Le contraste peut ecirctre configureacute dans le menu principal
2) MANETTE Functions Selector et Push EnterCe controcircle permet de se deacuteplacer de seacutelectionner et de modifier les paramegravetres dans les menus affichables agrave leacutecranRotation de la manette (Functions Selectors)- permet de se deacuteplacer sur les diffeacuterentes pages du menu - permet de modifier les paramegravetres seacutelectionneacutesPression de la manette (Push Enter)- permet de seacutelectionnervalider les paramegravetres
3) Bouton ESC Ce controcircle permet de quitter les menus afficheacutes ou de revenir agrave la visualisation preacuteceacutedente
4) Bouton Menu Ce controcircle permet dacceacuteder directement au menu principal
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
Fra
nccedilais
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
43
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
Fra
nccedilais
44
DVA Network
AC26N est eacutequipeacute dune interface de reacuteseau proprieacutetaire deacutenommeacutee RDNET au moyen de laquelle il est possible de sinterfacer agrave lordinateur agrave travers un peacuteripheacuterique (RDNET control)
Pour cela un protocole de communication a eacuteteacute deacuteveloppeacute avec lequel il est possible de recevoir et denvoyer les donneacutees ce branchement permet de faire le monitorage en temps reacuteel des paramegravetres du diffuseur comme puissance de sortie tempeacuterature de lamplificateur eacutetat du limiteur etc Il est aussi possible de seacutelectionner diffeacuterentes eacutegalisations ou den creacuteer de nouvelles et de reacutegler les niveaux de volume souhaiteacutes au moyen dun plug-in approprieacute
On conseille de teacuteleacutecharger gratuitement le logiciel DVA Network directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
DVA USB Manager
On conseille de teacuteleacutecharger gratuitement le logiciel DVA USB Manager directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
Le micrologiciel du module amplificateur peut ecirctre remis agrave jour par le port USBPour rendre cette mise agrave jour possible et facile un programme speacutecifique a eacuteteacute deacuteveloppeacute
DOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
CONNEXIONS DU PANNEAU ARRIEgraveRE
1586 75 141210 11 13 169 17
14) Connecteur ldquo USBrdquoCe connecteur USB (type B) permet de connecter le processeur agrave un ordinateur pour le controcircle et la mise agrave jour du micrologiciel via un programme deacutedieacute (DVA Network)
15) PRISE DALIMENTATION MAINSPermet la connexion du cacircble dalimentation fourni de seacuterie
16) PORTE-FUSIBLE FUSELogement pour fusible de ligne
17) INTERRUPTEUR GENERAL POWERLinterrupteur permet de mettre en marche ou deacuteteindre le controcircleur audio
COMMANDES ET FONCTIONS
5) SELECTEUR ldquo-6dBrdquoLe seacutelecteur permet de reacuteduire de 6dB les niveaux dentreacutee analogiques XLR [6] tout en compensant les niveaux eacuteleveacutes de sortie des meacutelangeurs ou dautres dispositifs audio Quand la barre du niveau de signal des entreacutees sur laffichage [1] reste au maximum cela indique que le niveau du signal entrant est eacuteleveacute Il est alors conseilleacute dutiliser latteacutenuation -6dBIl est possible de veacuterifier quand le seacutelecteur est activeacute par le menu Option
6) CONNECTEURS DENTREE ldquoArdquo ET ldquoBrdquoEntreacutees eacutequilibreacutees au niveau de la ligneIls sont en mesure daccepter des connecteurs XLR macircles
7) CONNECTEURS DE SORTIE ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo ET ldquo6rdquoSorties eacutequilibreacutees au niveau de la ligne Ils sont en mesure daccepter des connecteurs XLR femelles
Prendre garde agrave brancher convenablement les sorties sur les diffuseurs ou les amplificateurs en fonction des configurations de chaque canal pour eacuteviter des deacutegacircts et des problegravemes de fonctionnement
Section ldquoAESEBUrdquo
8) CONNECTEUR DENTREE INOutre les entreacutees audio analogiques une entreacutee audio numeacuterique SPDIF-AESEBU (AES3) a eacuteteacute preacutevue et peut ecirctre seacutelectionneacutee par le menu de setupLentreacutee requiert une connexion eacutequilibreacutee en utilisant un connecteur XLR avec un cacircble agrave 3 conducteurs de 110ohm torsadeacute
9) CONNECTEUR DE SORTIE OUTCe connecteur permet de relancer le signal audio dans les entreacutees analogiques ou numeacuteriques ou sur les sorties La source doit ecirctre reacutegleacutee par le menu OptionLa connexion sera conforme agrave la mecircme norme que lentreacutee [reacutef8]
Section ldquoRDNETrdquo
10) CONNECTEUR DENTREE DATA INPUTConnecteur RJ45 entreacutee de donneacutees
11) CONNECTEUR DE SORTIE DATA LINKConnecteur RJ45 sortie de donneacutees pour la connexion de seacuterie en cascade
12) VOYANT LUMINEUX ONCe voyant de couleur verte sallume uniquement quand lAC26N a reconnu et est connecteacute agrave luniteacute principale RDNET par lordinateur
13) VOYANT LUMINEUX ACTIVECe voyant de couleur jaune clignote quand une transmission des donneacutees est active entre RDNET et le dispositif
PUSH
P SHU
SHPU
P SHU
PUSH
CONNEXIONS
Audio analogiquesLes connexions eacutequilibreacutees permettent de reacuteduire au minimum le bruit provoqueacute par les cacircbles et dutiliser de longs cacircblesCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLe connecteur XLR doit ecirctre brancheacute avec la broche 1 agrave la masse la broche 2 au chaud (+) et la broche 3 au froid (-) En cas de cacircble blindeacute brancher le blindage agrave la broche 1Les cacircbles de connexion XLR-XLR et XLR-Jack14(63mm) peuvent semployer pour la connexion agrave lAC26N
12
3
Entreacutee
Entreacutee
XLR - femme
XLR - femme
1 2
3
Sortie
Sortie
XLR - Macircle
XLR - Macircle
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2 = Point chaudPhase +VE
Broche 3 =Point froidPhase -VE
Broche 3 =Point froidPhase -VE
Anneau
Manchon
Pointe Point chaudPhase +VE
Anneau = Point froidPhase -VE
ManchonB Masselindeacute
Pointe
Les connexions deacuteseacutequilibreacutees peuvent semployer mecircme si le bruit provoqueacute par les cacircbles augmente Les cacircbles ne peuvent deacutepasser 5m de longCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLes connexions deacuteseacutequilibreacutees peuvent abaisser le niveau du signal entrant de 6dB Pour remeacutedier agrave cet inconveacutenient il faut brancher la broche 3 agrave la masse mecircme si cela augmente le bruit
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
45
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
46
12
3
1 2
3
Pointe Manchon
Pointe = Signal
Broche 3 = Link to Pin 1
Broche 3 = Link to Pin 1
ManchonB Masselindeacute
Audio numeacuteriques (AESEBU)
AESEBU (protocole AES3) est une entreacutee eacutequilibreacutee isoleacutee eacutelectriquement agrave laide dun transformateur Elle permet demployer deux canaux audio dans un seul cacircble bipolaire blindeacute Les caracteacuteristiques du cacircble doivent ecirctre de 3 pocircles impeacutedance 100ohm torsadeacute et blindeacute avec connecteur XLR (AES3 standard)
RJ 45
|1|2|3|4|5|6|7|8|
RDnet
Chaque port RDNet des Control 2 et Control 8 peut ecirctre brancheacute agrave un maximum de 32 dispositifs compatibles placeacutes en cascade Dans lexemple suivant le port de luniteacute de controcircle RDNET CONTROL 2 est relieacute agrave lentreacutee DATA INPUT dun AC26N dont la sortie parallegravele DATA LINK est envoyeacutee agrave lentreacutee de lAC26N successif Dans lexemple [n] est un nombre compris entre 3 et 32 (limite maximale des dispositifs que lon peut relier agrave un sous-reacuteseau)
La longueur totale du cacircble CAT5 dun sous-reacuteseau NE peut PAS deacutepasser 900 megravetres
Le connecteur doit ecirctre relieacute comme 1 ndash disponible pour dautres fonctions (par exemple audio +) 2 ndash disponible pour dautres fonctions (par exemple audio )3 ndash disponible pour dautres fonctions (par exemple masse analogique)4 ndash masse numeacuterique5 ndash masse numeacuterique6 ndash disponible pour dautres fonctions (par exemple alimentation)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
MISE EN MARCHE
Lors de la mise en marche du dispositif linitialisation deacutebute et dure quelques secondes Leacutecran affiche le modegravele le logo et la barre de progression du chargement du programme
En fin de processus dinstallation leacutecran affiche la fenecirctre du menu Meters Pour connaicirctre les indications en deacutetail consulter le paragraphe DESCRIPTION FENETRE MENU Meters
LAC26N est precirct agrave lemploi
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION ET VISUALISATION
Pour entrer dans la fenecirctre du menu principal il faut pousser sur la touche MENU ( ) agrave lavant du dispositifDune page quelconque du menu en poussant sur la touche ESCrdquo ( ) on revient automatiquement sur la page-eacutecran preacuteceacutedente
MENU PRINCIPAL
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Le processeur contient six menus Ils montrent etou configurent les paramegravetres du systegravemeLes menus principaux sont
Meters Visualisation des niveaux des entreacutees et des sorties visualisation du programme utiliseacute et eacutetat mute rapide
Preset Meacutemoriser enregistrer et eacuteliminer les configurations du systegraveme
Matrix seacutelectionner les sorties en fonction du signal entrant
Ch Job configuration de chaque signal
X-Over configurer les freacutequences de coupure et les types de filtres pour chaque sortie
Option attribution des entreacutees et des sorties contraste daffichage la version du micrologiciel les entreacutees et dautres options
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
47
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
48
DESCRIPTION DE LA FENETRE MENU Metersrdquo
Cette fenecirctre permet de visualiser les configurations et leacutetat geacuteneacuteral des entreacutees et des sorties la version du programme utiliseacute son eacutetat et le mode de pilotage du systegraveme
Les menus et les options afficheacutees peuvent se seacutelectionner en tournant la manette ldquoFUNCTIONS SETECTORrdquo ( ) Pour avoir accegraves agrave linteacuterieur de la seacutelection il faut mettre le paramegravetre souhaiteacute en eacutevidence et pousser sur la manette ldquoPush Enterrdquo ( | ) Il faut en faire de mecircme pour seacutelectionner etou modifier les options dans les commandes du menu
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositifAvec des signaux dentreacutee numeacuteriques les indications ldquoArdquo et ldquoBrdquo correspondent agrave lentreacuteeEn tournant la manette ldquoFUNCTIONS SELECTORrdquo [2] on fait deacutefiler en mode cyclique les canaux dentreacutee de sortie et lindication de mute geacuteneacuteral (d) le canal seacutelectionneacute est mis en eacutevidence
b) BARRE DE NIVEAU DE COMPRESSIONMUTE CANAL
COMPRESSION DE SIGNALLa compression du signal est visualiseacutee par le deacutefilement de la barre de droite de haut en bas
MUTE Chaque canal peut ecirctre placeacute en mute Seacutelectionner le canal et pousser sur la manette ldquoPush Enterrdquo [2] pour valider le changement deacutetat Lindication du canal sera remplaceacutee par la lettre M et la barre sera totalement mise en eacutevidencePour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterations
c) BARRE DE NIVEAU DE SIGNALLindication du niveau de chaque canal est signaleacutee par le deacutefilement de la barre de gauche
d) MUTE GENERALIl est possible de mettre simultaneacutement toutes les entreacutees et les sorties en mute Tourner la manette ldquoFUNCTIONS SELECTORrdquo seacutelectionner la lettre M et pousser sur la manette Push EnterPour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterationsLe mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) MODES DE COMMANDEIl affiche le mode dutilisation etou les dispositifs qui sont relieacutes agrave lAC26N
Local = utilisation autonome Aucune connexion agrave un dispositif exteacuterieur
NET = relieacute directement au reacuteseau deacutedieacute RDNet et agrave lordinateur
USB = relieacute directement agrave un ordinateur par cacircble USB
f) INDICATION DETAT DE PARAMETRAGECette indication permet de constater si un ou plusieurs paramegravetre(s) du programme chargeacute aont eacuteteacute modifieacute(s) par rapport au dernier sauvetage
= programme dorigine
= programme avec des paramegravetres modifieacutes
g) PROGRAMME CONFIGURELe chiffre indique le programme chargeacute et utiliseacute par le systegraveme agrave lemplacement de sauvetage Consulter le menu de Preset pour de plus amples deacutetails
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
DESCRIPTION DE LA FENETRE MENU Ch Job
Cette fenecirctre permet dafficher la configuration de chaque canal
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) NIVEAU DU SIGNALIndique le gain du signal Laugmentation de lintensiteacute dun signal est libelleacutee en deacutecibel (dB) Le paramegravetre peut ecirctre seacutelectionneacute de -8000dB agrave +2000dB avec des pas de 001dB Une augmentation de 6dB est eacutegale approximativement au redoublement agrave leacutechelle lineacuteaire du niveau du signal sous tensionAvec un gain supeacuterieur agrave 0dB le signal est amplifieacute tandis quavec un gain infeacuterieur agrave 0dB le signal est atteacutenueacute
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
49
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
50
c) DELAI DU SIGNAL (DELAY)Le signal audio reproduit peut ecirctre retardeacute pour permettre lalignement acoustique Cela compense les diffeacuterentes positions des diffuseurs pendant linstallation et la reproduction sonore Il se libelle en mS Le paramegravetre peut ecirctre seacutelectionneacute de 00mS agrave 729mS avec un pas de 01mSPour aligner un signal audio il est possible dutiliser la formule suivante
Deacutelai = (GAPx1000)344
Deacutelai = ms (en millisecondes)GAP = distance du diffuseur du point de reacutefeacuterence (en megravetres)Vitesse du son = 344ms
d) MUTEChaque canal peut ecirctre placeacute en mute La mecircme commande peut ecirctre activeacutee dans la fenecirctre du menu meters NB Le mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) PhasePermet la rotation de phase de 180deg par rapport au signal entrantCette rotation permet loptimisation surtout des basses freacutequences dans les installations complexes
f) EGALISATIONCette commande ouvre la fenecirctre du menu deacutegalisation de chaque canal Elle sert surtout pour corriger une ou plusieurs freacutequences qui doivent ecirctre atteacutenueacutees ou augmenteacutees
M M
LAC26N gegravere 12 filtres par canal dentreacutee et sortie avec trois types de configurations diffeacuterentes - Leacutegaliseur PEQ (peaking equalizer) est ideacuteal pour identifier isoler et
corriger une seule plage de freacutequences bien deacutetermineacutee Toutes les freacutequences passent mais il augmente ou diminue uniquement celles autour de la freacutequence centrale pour une bande preacutecise et un gain deacutefini
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessus de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessous de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
f Numeacuterotation des 12 filtres disponibles pour cette entreacutee ou cette sortie1
f Le type de filtre est afficheacute 2
Dis Deacutesactiveacute (absent)
PEQ Peaking equlizer
Sh H Filtre high-shelf
Sh L Filtre high-shelf
Exemples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
REMARQUELe paramegravetre Bw deacutetermine le champ de freacutequences adjacent agrave la freacutequence configureacutee ougrave est activeacute le filtre Plus la valeur Bw est eacuteleveacutee plus vaste est le champ de freacutequences (1Bw=1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONCette commande ouvre la fenecirctre du menu de compression de chaque canal
g1) TresholdIdentifie le seuil ougrave commence le rapport de compression La valeur de base 11
g2) RatioIndique le rapport de conversion entre le signal entrant et le signal sortant
g3) Post Gain Attach Release HoldCes donneacutees deacutependent du rapport de conversion que lon veut obtenir - Post Gain est le gain de sortie- Attack est le temps dattaque - Release est le temps de relacircchement- Hold est le temps de maintien
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
52
DESCRIPTION DE LA FENETRE MENU Preset
Cette fenecirctre permet de meacutemoriser jusquagrave 32 configurations dans lAC26NLe fabricant fournit le systegraveme avec un programme configureacute et enregistreacute en position 0 et non susceptible deacutecrasement
032 Elle indique lemplacement de sauvetage de la configurationCe numeacutero apparaicirct dans la fenecirctre Meters en position (g) A tout moment le programme utiliseacute peut ecirctre afficheacute par lutilisateur
Empty Preset Cest le nom qui est associeacute au numeacutero de lemplacement quand aucune configuration (vide) nest enregistreacutee
Local preset Local preset est le nom qui est associeacute au numeacutero de lemplacement quand on enregistre une configuration NB = Il est possible denregistrer une configuration avec lenom souhaiteacute de 16 lettres tout au plus agrave condition que lonutilise linterface via lordinateur
Le nom du programme assigneacute est indiqueacutePour toucher agrave lapplication 3 choix soffrent agrave vous
Save Le programme est enregistreacute en meacutemoire de lAC26N
Del Le programme est effaceacute
Load Le programme est chargeacute et precirct agrave lemploi
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
51
DESCRIPTION DE LA FENETRE MENU X-Over
Cette fenecirctre permet de seacutelectionner un filtre passe bas un filtre passe haut ou par la combinaison des deux de creacuteer un filtre passe bande pour chaque sortieLe filtre actif est un Linkwitz-Riley qui permet de seacutelectionner la pente de 12dBoct 24dBoct ou 48dBoct et sa freacutequence de coupure
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) CANAUX DE SORTIE
Les connecteurs de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) FILTRE CROSSOVERSeacutelectionner le filtre selon les besoins Il est possible de seacutelectionner
Dis Aucun filtre activeacute
HP Filtre passe-haut laisse passer uniquement la partie de signal audio supeacuterieure agrave la freacutequence de coupure
LP Filtre passe-bas laisse passer uniquement la partie de signal audio infeacuterieure agrave la freacutequence de coupure
Configuration du filtre Passe-haut Passe-bas
Rien Dis Dis
Passe-haut HP Dis
Passe-bas Dis LP
Passe-bande HP LP
12dBoct
24dBoct
Hz
dB
Ga
in 48dBoct
12dBoct
24dBoct
Hz
dB
Ga
in
48dBoct
c) PENTE DATTENUATIONSeacutelectionner la pente datteacutenuation du signal audio en fonction de la diminution que lon veut obtenir Plus la pente datteacutenuation est eacuteleveacutee agrave eacutegaliteacute de freacutequence de coupure plus eacuteleveacutee sera la seacutelection du signal Il est possible de seacutelectionner
12 correspond agrave 12dboct
24 correspond agrave 24dboct
48 correspond agrave 48dboct
d) FREQUENCE DE COUPUREElle permet de reacutegler la freacutequence de passage des freacutequences infeacuterieures (filtre passe-bas) ou des freacutequences supeacuterieures (filtre passe-haut) uniquementLe choix de la coupure deacutepend de la reproduction que lon veut obtenirLuniteacute de mesure utiliseacutee est lHz
Hz
Hz
dB
dB
Ga
in
f0
f0
0dB0dB
0dB
-6dB
freacutequence
freacutequence
freacutequence
freacutequence
Ga
in
f0
0dB
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
53
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
54
DESCRIPTION DE LA FENETRE MENU Matrix
Elle permet de seacutelectionner le signal entrant agrave utiliser comme source pour chaque sortie
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) CANAUX DE SORTIEIdentification du canal sortant agrave reacutegler
b) IDENTIFICATIONS DES ENTREESSeacutelectionner le type de signal agrave associer agrave chaque sortie en fonction des besoins Il est possible de seacutelectionner
In A Le signal entrant A est associeacute
In B Le signal entrant B est associeacute
In A+B La somme algeacutebrique des deux signaux entrants A et B est associeacutee
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
DESCRIPTION DE LA FENETRE MENU Option
Permet dafficher les reacuteglages du systegraveme comme lassignation des entreacutees et des sorties latteacutenuation le contraste de laffichage et la version du logiciel
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcCette option permet de reacutegler le type de signal audio entrant
An In =signaux audio analogiques (entreacutees ldquoArdquo et ldquoBrdquo)
Dig In =signaux audio numeacuteriques (entreacutee AESEBU)
DigOut SrcCette option permet de seacutelectionner la source audio qui sera adresseacutee sur le connecteur AESEBU OUT (sortie numeacuterique)
An In = signaux audio des entreacutees analogiques
Dig In =signaux audio sur lentreacutee numeacuterique
OUT 1-2 = signaux audio sur les sorties 1 et 2
OUT 3-4 = signaux audio sur les sorties 3 et 4
OUT 5-6 = signaux audio sur les sorties 5 et 6
Input ModePermet de configurer les entreacutees
Indip = sont indeacutependantes et autonomes Ne sont soumises agrave aucun type de lien
Linked = sont unies et fonctionnent en mode steacutereacuteo Les compresseurs les filtres les deacutelais le volume sont identiques pour les deux canaux
Atten PadIndique le mode de reacuteglage du seacutelecteur ldquo-6dBrdquo placeacute agrave larriegravere [reacutef 5] Il faut activer ce seacutelecteur quand les niveaux dentreacutee analogiques sont trop eacuteleveacutes Le seacutelecteur sactive uniquement par le bouton Dans le menu il sagit dune simple visualisation
0dB = seacutelecteur non activeacute Les signaux dentreacutee sont identiques agrave la source entrante
-6dB = seacutelecteur activeacute Les signaux entrants sont atteacutenueacutes de -6dB par le processeur interne
ContrastIl permet de reacutegler le contraste de laffichage agrave cristaux liquides pour compenser la diffeacuterence de luminositeacute avec le lieu dinstallation Une plus grande clarteacute de laffichage permet de naviguer convenablement et rapidement dans les menusLe reacuteglage agrave la sortie de lusine du fabricant est de 60
10 plus clair 60 plus fonceacute 100
Fw VersIndique la version du logiciel du processeur
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
55
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
56
DONNES TECHINIQUES
PERFORMANCES AUDIOReacuteponse en freacutequence +- 01dB (20 to 30kHz)Plage dynamique 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsion 0002 (1kHz +4dBu)
PERFORMANCES AUDIO NUMERIQUES Processeur DSP 2856-bit Freacutequence de traitement des donneacutees 48KHzConvertisseurs analogiques 24-bit BURR BROWNDeacutelai de propagation 15msMeacutemorisations des configurations 32 preset
CONTROLES Affichage LCD graficoBoutonsCommandes ESC - MENU - FUNCTIONS SELECTION
ENTERENTREESSORTIESEntreacutee analogique ndeg2 x XLR (3 broches femelle)
Impeacutedance dentreacutee gt10KOhmNiveau maximum +21dBu senza PAD
+27dBu con PADSortie analogique ndeg6 x XLR (3 broches macircle )
Impeacutedance de sortie 50OhmNiveau maximum +21dBuType Balanceacute
Entreacutee numeacuterique ndeg1x XLR (3 broches femelle)Type SPDIF-AESEBU (AES3)
Sortie numeacuterique ndeg1x XLR (3 broches macircle )Type conforme agrave la norme de lentreacutee
EntreacuteesSortie Rdnet ndeg2 x XLR RJ45 (cacircble CAT 5)USB Type B
PARAMETRES DE CONTROLE DU SONGain -80dB a +20dB eacutetape 01dBDeacutelai Entreacutee 0 a 729mS eacutetape 01 mS
Sortie 0 a 340mS eacutetape 01mSRotation de phase 0deg - 180deg
COMPRESSIONSeuil -80dB a +20dB eacutetape 01dBRapport 11 a Inf1 eacutetape 001Gain agrave la sortie 0dB a 40dB eacutetape 01dBTemps dattaque 1mS a 1000mS eacutetape 01mSTemps de relacircchement 1mS a 1000mS eacutetape 01mSTemps de maintien 1mS a 1000mS eacutetape 01mS
EGALISEURS12 eacutegaliseurs pour chaque entreacutee et sortieType PEQ (parameacutetrique) Hi-shelf Lo-sheft
Freacutequence 20Hz a 20KHz eacutetape 1HzGain -30dB a +15dB eacutetape 001dBBande 005dB a 2dB eacutetape 001dB (uniquement pour PEQ)
FILTRES CROSSOVERFiltre Linkwitz Riley
Type HF high-shelfLF low-shelf
Pente 12dBoct - 24dBoct - 48dBoctFreacutequence de coupure 5Hz a 20KHz eacutetape 1Hz
ALIMENTATION Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)POIDS 19Kg
Remarques Speacutecifications sujettes agrave modifications sans preacuteavis
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
2 VIE ATTIVO2 WAY ACTIVE
3 VIE PASSIVO3 WAY PASSIVE
L
L
A
A
HIGH L
MID L
LOW HIGHMID RHIGHMID L
LOW L
HIGH R
MID R
LOW R
R
R
B
B
1
1
2
2
3
3
456
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
Menu Matrix configurationMatrix
57 58
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
EROUIG ATRIX TNM
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
OU
TP
UT
1
OU
TP
UT
2
OU
TP
UT
3
OU
TP
UT
4
OU
TP
UT
5
OU
TP
UT
6
AE
S-E
BU
OU
TP
UT
INP
UT
A
AE
S-E
BU
INP
UT
INP
UT
B
D D D D D D
D D
A A A A A A
A SA
MP
LE
RA
TE
CO
NV
A
LIN
KA
BL
E
SC
HE
MA
A B
LO
CC
HI -
BL
OC
K D
IAG
RA
MB
LO
CK
SC
HA
LT
BIL
D -
SC
HE
MA
S F
ON
CT
ION
NE
LS
LINE ARRAY SUB MONO ATTIVO
LINE ARRAY SUB MONO ACTIVEINGRESSI - INPUT
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
L
L
L
A
A
A
AESEBU IN
AESEBU IN
AESEBU IN
AESEBU OUT
AESEBU IN
AESEBU IN
AESEBU OUT
R
R
R
LR
B
B
B
123456
HIGHMID L
HIGHMID L HIGHMID R
HIGHMID R
LOW L LOW R
LAYER
DISPLAY MEMORY
FADER MODE
LAYER
DISPLAY MEMORY
FADER MODE
Ingresso ANALOGICO
ANALOG Input
Collegamento in cascata
Link connections
Ingresso DIGITALE
DIGITAL inputA B
BALANCED AUDIO INPUTS
-6dB
PUSH PUSH
IN OUT
AES EBUPUSH
Oppure
or
Oppure
or
Menu Option configurationOption
Menu Option configurationOption Menu Option configurationOption
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type Analog
AES out An In
Input type Analog
AES out An In
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
59 60
InA-B Src Dig InInA-B Src Dig InInA-B Src An InInA-B Src An In
frequenzaHz
dB
Gu
ad
ag
no
60 200 2800
0dB0dB
-6dB
Esempio di un sistema a 3-vie
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
Out 1 Out 2 Out 3
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Esempio di un sistema a 3-vie
61 62
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
26NAC 26NAC
R TE
DO
R
MO LEU O R CE S
E O TR L A
S O
O C ND I P
P hsuernE t
o su cti nF nel rS e tc o
E CSME UN
IGCHTE OL SN EOBd
ocaL l
M
0
484
467
430
44
31
75
12
7
DIMENSIONI DIMENSIONSABMESSUNGEN DIMENSIONS
Digital Audio Connections (AESEBU)AESEBU (AES3 protocol) is and a balanced input electrically insulated by means of a transformer It allows carrying two audio channels in a single two-wires shielded cable The cable characteristics are twisted 3 poles impedance 100 ohm shielded equipped with XLR connector (AES3 standard)
RDnetEach RDNet port on Control 2 and Control 8 can be connected to maximum 32 cascade-connected compatible devices In the example below the control unit RDNET CONTROL 2 port is connected to the DATA INPUT of an AC 26N whose parallel DATA LINK output is sent to the input of the next AC26N In the example [n] is a number between 3 and 32 (maximum limit for the devices connected to a sub-network)
RJ 45
|1|2|3|4|5|6|7|8|
The overall length of a CAT5 sub-network cable cannot exceed 900 meters
The connector must be connected as follows
1 - Available for other functions (for example audio +) 2 - Available for other functions (for example audio -)3 - Available for other functions (for example analog ground)4 - digital ground5 - digital ground6 - Available for other functions (for example power supply)7 - RS 485 A8 - RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
POWER ON
When the device is turned on the initialization procedure starts It lasts few seconds The display shows the device model the company logo and a program loading progress bar
At the end of the installation process the display shows the Meters menu For further details about the indications refer to the paragraph MENU DESCRIPTION - METERS
AC26N is now ready for use
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION AND DISPLAY
To access the main menu window press the MENU key located on the device front panelIn any page of the menu press the ESC button to return to the previous screen
MAIN MENU
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
There are six menus in the processor They show andor configure the system parametersThe main menus are
Meters Input and output levels display program in progress display quick muting
Preset Store save and delete the system configurations
Matrix Select the outputs according to the input signal
Ch Job Configuration of each individual channel
X-Over Configuration of the cut-off frequency and the types of filters for each output
Option Assignment of the inputs and outputs display contrast firmware version inputs and other options
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
20
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
19
The menus and the individual options displayed can be selected by rotating the knob ldquoFUNCTION SELECTORrdquo ( ) To access the selection highlight the desired parameter and press the ldquoPush Enterrdquo ( | ) knobThe same procedure should be adoptd to select andor change the options inside each menu entry
MENU DESCRIPTION - ldquoMetersrdquo
This window allows to view the configuration and the general conditions of the inputs and outputs the version of the program used the program status and how the system is driven
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) INPUT AND OUTPUT CHANNELSThe input and output connectors are identified by the same information provided on the screen printing located on the device rear sideWith digital input signals the indications A and B concern the inputBy rotating the knob FUNCTION SELECTOR [2] input channels output channels and general muting indications are cyclically scrolled (d) the selected channel is highlighted
b) BAR COMPRESSION LEVEL CHANNEL MUTING
SIGNAL COMPRESSIONSignal compression is displayed by the vertical scrolling (top to down) of the right bar
MUTE Each channel can be individually muted Select the channel and press the Push Enter knob [2] to confirm the change of status The indication of the channel will be replaced by the letter M and the bar will be completely highlightedTo restore normal operation repeat the actions described above
c) SIGNAL LEVEL BARThe level indication for each channel is provided by scrolling the left bar
d) GENERAL MUTINGIt is possible to mute all the inputs and outputs simultaneously Rotate the knob FUNCTION SELECTOR select the letter M and press the Push Enter knobTo restore normal operation repeat the actions described aboveThe general mute has the highest priority with respect to the muting of individual channels
e) CONTROL MODEIt shows how the AC26N is used andor to which devices it is connected
Local = stand-alone usage No connection to an external device
NET = directly connected to dedicated RDnet network and to computer
USB = directly connected to another computer via USB cable
f) SETTING STATUS INDICATIONThis indication shows if the loaded program was amended in one or more parameters with respect to the last saving operation
= original program
= program with modified parameters
g) SET PROGRAMThe number shows the program that is loaded and used by the system with reference to the saving position Refer to the ldquoPresetrdquo menu for further details
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
MENU DESCRIPTION - CH JOB
This window allows to view the configuration of each individual channel
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) INPUT AND OUTPUT CHANNELSThe input and output connectors are identified by the same information provided on the screen printing located on the device rear side
b) SIGNAL LEVELIt shows the signal gain The increased signal intensity is expressed in decibels (dB) Such parameter can be selected in the range from -8000 dB to +2000 dB in steps of 001 dB An increase of 6 dB is approximately equal to doubling - in a linear scale - the signal voltage levelIf the gain exceeds 0 dB the signal is amplified while if the gain is lower than 0 dB the signal is attenuated
c) SIGNAL DELAYThe reproduced audio signal may be delayed to perform an acoustic alignment This compensates for the different positions of the speakers during the installation and the sound reproduction it is expressed in ms The parameter can be selected in the range from 00 ms to 729 ms in steps of 01 msThe following formula can be used to align an audio signal
Delay = (GAPx1000)344
Delay = ms (in milliseconds)GAP = distance between speaker and reference point (in meters)Speed of sound = 344 ms
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
22
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
21
d) MUTEEach channel can be individually muted The same command can be activated in the Meters Menu
NOTE The general mute has the highest priority with respect to the muting of individual channels
e) PhaseIt performs a phase rotation of 180deg with respect to the input signalSuch phase rotation allows the optimization in special way for low frequencies in complex installations
M M
f) EQUALIZATIONThis control opens the menu controlling the single channel equalization It is mainly used to correct one or more frequencies that must be reduced or increased
The AC26N manages 12 filters for each individual channel input and output with three different kinds of configuration
- PEQ Equaliser (peaking equalizer) ideal to identify isolate and correct only a certain range of frequencies All frequencies pass only those around the centre frequency are increased and decreased for a given bandwidth and set gain
- High-shelf Equalizer All frequencies pass but frequencies above the selected cut-off frequency are increased or attenuated by the given gain
- Low-shelf Equalizer All frequencies pass but frequencies below the selected cut-off frequency are increased or attenuated by the given gain
f Numbering of the 12 available filters for the specific input or output1
f Displays the kind of filter2
Dis Switched off (not present)
PEQ Peaking equlizer
Sh H High-shelf Filter
Sh L Low-shelf Filter
Examples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
NOTE
The parameter Bw defines the range of frequencies close to the set frequency where the filter is activated the greater the value of Bw the wider is the frequencies range (1 Bw = 1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONThis control opens the menu controlling the compression for the single channel
g1) ThresholdIdentifies the starting threshold for the compression ratio Base value 11
g2) RatioIndicates the conversion ratio between input and output signal
g3) Post Gain Attach Release HoldThese data are in function of the conversion ratio to achieve Post Gain is the output gain Attack is the attack time Release is the release time Hold is the holding time
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
24
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
23
MENU DESCRIPTION - PRESET
This window allows to store up to 32 configurations in the AC26NThe manufacturer provides the system with a program set and saved in position 0 that is not possible to overwrite
032 Indicates the location where the configuration is savedThis number also appears in the window Meters in position (g) The program in use can be displayed at any time by the user
Empty Preset It is the name associated with the location number when no setting is saved (empty)
Local preset It is the name associated with the location number when a setting is saved NOTE = It is possible to save a setting with the desired name up to 16 letters only via the computer interface
When a program is selected the following window is displayed
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
The name of the assigned program is displayed3 possible choices are available when working on the application
Save The program is saved in the AC 26N memory
Del The program is deleted
Load The program is loaded and ready to be used
MENU DESCRIPTION - X-OVER
This window allows to select for each output a low pass filter a high pass filter or create a band-pass filter via the combination of bothThe available filter is a Linkwitz-Riley where it is possible to select slopes of 12 dBoct 24 dBoct or 48 dBoct and their cut-off frequency
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) OUTPUT CHANNELS
The output connectors are identified by the same information provided on the screen printing located on the device rear side
b) CROSSOVER FILTERSelect the filter according to needs It is possible to select
Dis No filter enabled
HP High-pass filter set it to allow only the part of audio signal above the cut-off frequency
LP Low-pass filter set to allow only the part of audio signal below the cut-off frequency
Filter configuration Low-pass High-pass
Nothing Dis Dis
High-pass HP Dis
Low-pass Dis LP
Band-pass HP LP
12dBoct
24dBoct
Hz
dB
48dBoct
12dBoct
24dBoct
frequency
frequency
frequency
frequency
Hz
dB
48dBoct
c) ATTENUATION SLOPESelect the attenuation slope of the audio signal on the basis of the desired attenuation The higher the attenuation slope at the same cut-off frequency the greater the signal selection It is possible to select
12 equal to 12 dBoct
24 equal to 24 dBoct
48 equal to 48 dBoct
d) CUT-OFF FREQUENCYTo set the passing frequency for the lower frequencies only (low-pass filter) or the higher frequencies only (high-pass filter)The choice of the cut-off depends on the desired sound reproductionThe unit of measurement used is Hz
Hz
Hz
dB
dB
Ga
inG
ain
Ga
inG
ain
f0
f0
0dB0dB
0dB
-6dB
-6dB
0dB
0dB
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
26
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
25
MENU DESCRIPTION - MATRIX
For each output it allows to select the input signal to use as the source
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) OUTPUT CHANNELSIdentification of the output channel to set
b) IDENTIFICATIONS OF THE INPUTSIt selects the type of signal to match each output as needed It is possible to select
In A Associated with the input signal ldquoArdquo
In B Associated with the input signal ldquoBrdquo
In A+B Associated with the algebraic sum of the two input signals ldquoArdquo and ldquoBrdquo
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
MENU DESCRIPTION - OPTION
Allows to display the system settings such as the allocation of the inputs and outputs attenuation display contrast and firmware version
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcThis option allows to set the type of input audio signal
An In = Analog audio signals (inputs A and B)
DigIn = Digital audio signals (AESEBU input)
DigOut SrcThis option allows to select the audio source that will be forwarded to the connector AESEBU OUT (digital output)
An In = Audio signals available at analog inputs
Dig In = Audio signals available at digital inputs
OUT 1-2 = Audio signals available on outputs 1 and 2
OUT 3-4 = Audio signals available on outputs 3 and 4
OUT 5-6 = Audio signals available on outputs 5 and 6
Input ModeIt allows to configure the inputs
Indip = They are independent not subject to constraints of any kind between them
Linked = They are connected and work in stereo mode Compressors filters delays volume are identical for the two channels
Atten PadIt shows how to set the -6 dB switch located on the rear side [Ref 5] It is necessary to activate this selector when the analog input levels are too high The selector can be activated only by means of the button the menu is for display only
0 dB = Selector not activated The input signals are the same as the input source
-6 dB = Selector activated The input signals are attenuated by -6 dB with reference to the inner
processor
ContrastAllows to adjust the LCD display contrast to compensate for the brightness difference at the installation sites Greater display brightness allows to navigate correctly and quickly within the menuThe manufacturer output setting is 60
10 More bright 60 More dark 100
Fw VersIt shows the processor firmware version
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
28
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
27
TECHINICAL SPECIFICATION
AUDIO PERFORMANCEFrequency Response +- 01dB (20 to 30kHz)Dynamic Range 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistortion 0002 (1kHz +4dBu)
DIGITAL AUDIO PERFORMANCE Processor DSP 2856-bit Data processing Frequency 24-bit BURR BROWNAnalog converters 24-bit BURR BROWNPropagation Delay 15msStoring configurations 32 preset
CONTROLS Display LCD graficoButtonsControls ESC - MENU - FUNCTIONS SELECTION
ENTERINPUTSOUTPUTSAnalog Input ndeg2 x XLR (3 pole female)
Input impedance gt10KOhmMaximum Level +21dBu senza PAD
+27dBu con PADAnalog Output ndeg6 x XLR (3 pole male)
Output impedance 50OhmMaximum Level +21dBu Type Balanced
Digital Input ndeg1x XLR (3 pole female)Type SPDIF-AESEBU (AES3)
Digital Output ndeg1x XLR (3 pole male)Type Compliant with the input standard
RDnet InputsOutput ndeg2 x XLR RJ45 (CAT 5 cable)USB Tipo B
SOUND CONTROL PARAMETERSGain -80dB a +20dB step 01dBDelay
Input 0 a 729mS step 01 mSOutput 0 a 340mS step 01mSPhase Rotation 0deg - 180deg
COMPRESSIONThreshold -80dB a +20dB step 01dBRatio 11 a Inf1 step 001Output gain 0dB a 40dB step 01dBAttack time 1mS a 1000mS step 01mSRelease time 1mS a 1000mS step 01mSHold time 1mS a 1000mS step 01mS
EQUALIZERS12 equalizers for each input and outputType PEQ (parametrico) Hi-shelf Lo-sheft
Frequency 20Hz a 20KHz step 1HzGain -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (only with PEQ)
CROSSOVER FILTERSFilter Linkwitz Riley
Type HP High-pass LP Low-pass
Slope 12dBoct - 24dBoct - 48dBoctCUT-OFF FREQUENCY 5Hz a 20KHz passo 1Hz
POWER SUPPLY Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)
1719x17x51 inch (WxHxD)WEIGHT 19Kg
(42 lbs)Note Specifications subject to change without notice
EMI CLASSIFICATIONAccording to the standards EN 55103 this equipment is designed and suitable to operate in E3 (or lower E2 E1) Electromagnetic environments
EINLEITUNG
Verpackungsinhalt
Eigenschaften
AC26N ist ein digitaler Audio-Prozessor fuumlr die Verwaltung von Audio-Systemen der fuumlr feste und mobile Installationen entwickelt wurde AC26N benutzt die modernste Technologie mit 2856 bit-Prozessoren und 24-bit-ADDA-Wandlern mit hoher Leistungsfaumlhigkeit Die verfuumlgbaren Funktionen des Prozessors sind Ein- und Ausgangsstufen Verzoumlgerung (delay) Polaritaumlt 12 Equalizer-Frequenzen fuumlr Ein- und Ausgangskanal viele Crossover-Wahlmoumlglichkeiten und Limiter mit hoher Leistung Die Filter-Kontrolle hat eine Aufloumlsung von 1 Hz Die Ein- und Ausgaumlnge koumlnnen mit unterschiedlichen Einstellungen geregelt werden um allen Anforderungen gerecht zu werden AC26N kann in Echtzeit kontrolliert werden und jeder Parameter kann am Frontpaneel und vom Computer mit intuitiver graphischer Schnittstelle mittels Software DVA Network zugaumlnglich und einer Netzverbindung RDnet oder uumlber USB eingestellt werdenDie SW-Aktualisierung fuumlr CPU und DSP uumlber PC erlaubt die Vorrichtung auf dem aktuellen Stand zu halten Man kann 32 vorgesehene Konfigurationen speichern und aufrufen
- AC26N - Bedienungsanleitung- Software-CD- Versorgungskabel
- 2 Ein- und 6 Ausgaumlnge mit flexibler Adressierung- Adressierbarer Stereo-Ein- und Ausgang AESEBU - DSP 2856-bit- AD-Wandler BURR BROWN 24-bit mit hoher Leistungsfaumlhigkeit- Aufloumlsungsfrequenz der Filter 1 Hz - 12 parametrische Equalizer fuumlr jeden Ein- und Ausgang- 2 Crossover-Filter fuumlr jeden Ausgang mit auswaumlhlbarer Neigung 122448dBoct- DRC Multikonfiguration mit hoher Leistungsfaumlhigkeit fuumlr die Konfiguration des
Limitersder Kompression jedes Ein- und Ausgangs- Einstellbare dB-Stufe Polaritaumlt und Verzoumlgerung (delay) fuumlr jeden Ein- und Ausgang- Firmware-Aktualisierung uumlber PC- Graphisches LCD-Display- 32 Voreinstellungen vom Benutzer einstellbar- USB-Schnittstelle fuumlr die Kontrolle und Konfiguration mit dem Computer- Schnittstelle RDnet welche erlaubt bis zu 256 fern liegende Vorrichtungen
zu kontrollieren
PC
PC
RDNET control(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FUNKTIONEN VORDERSEITE
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
BEDIENUNGEN UND FUNKTIONEN
1) DISPLAYDas graphische LCD-Display erlaubt die Informationen des AC26N ohne einen Computer zu benutzen anzuzeigen und zu editieren Der Kontrast kann im Hauptmenuuml eingestellt werden
2) DREHGRIFF Functions Selector UND Push EnterDiese Kontrolle erlaubt sich in den Menuumls auf dem Display zu bewegen und die Parameter auszuwaumlhlen und zu veraumlndernDrehung des Drehgriffes (Functions Selectors)- Man kann sich innerhalb der verschiedenen Menuumlseiten bewegen- Erlaubt die Veraumlnderung der ausgewaumlhlten ParameterDruck des Drehgriffes (Push Enter)- Erlaubt die AuswahlBestaumltigung der Parameter
3) Taste ldquoESCrdquo Diese Kontrolle erlaubt die angezeigten Menuumls zu verlassen oder zur vorherigen Anzeige zuruumlckzukehren
4) Taste ldquoMenuumlrdquo Diese Kontrolle erlaubt den direkten Zugang zum Hauptmenuuml
Deuts
chD
euts
chB
ed
ien
un
gsan
leit
un
gB
ed
ien
un
gsan
leit
un
g
29
Deuts
chD
euts
chB
ed
ien
un
gsan
leit
un
gB
ed
ien
un
gsan
leit
un
g
30
DVA USB Manager
Die Firmware des Verstaumlrkermoduls kann uumlber den USB-Anschluss aktualisiert werdenUm diesen Vorgang zu ermoumlglichen und zu vereinfachen wurde ein dediziertes Programm entwickelt das beim Hersteller angefordert und auf einen Computer installiert werden muss
Wir empfehlen die Software DVA USB Manager direkt von der Webseite dB Technologies (wwwdbtechnologiescom) im Abschnitt laquoSoftware amp Controllerraquo herunterzuladen
DVA Network
AC26N ist mit einer eigenen als RDNET bezeichneten Netzschnittstelle ausgestattet dank der es uumlber ein Interface (RDNET Control) an einen Computer angeschlossen werden koumlnnenHierzu wurde ein Kommunikationsprotokoll entwickelt mit dem die Daten empfangen und gesendet werden Dank dieser Verbindung koumlnnen die Lautsprecherparameter wie Ausgangsleistung Verstaumlrkertemperatur Limiterstatus usw in Echtzeit kontrolliert werden Auszligerdem koumlnnen verschiedene Entzerrungen ausgewaumlhlt bzw neue erstellt werden oder die gewuumlnschte Lautstaumlrke eingestellt werden
Wir empfehlen die Software DVA_Network direkt von der Webseite dB Technologies (wwwdbtechnologiescom) im Abschnitt laquoSoftware amp Controllerraquo herunterzuladenDOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
RUumlCKWANDANSCHLUumlSSE
1586 75 141210 11 13 169 17
14) USB-SteckverbinderDieser USB-Steckverbinder (Typ B) erlaubt den Prozessor an einem Computer anzuschlieszligen um die Firmware mit dem speziellen Programm (DVA Network) zu kontrollieren und zu aktualisieren
15) STROMANSCHLUSS MAINSErlaubt den Anschluss des mitgelieferten Versorgungskabels
16) SICHERUNGSTRAumlGER FUSEAufnahme fuumlr die Netz-Sicherung
17) HAUPTSCHALTER POWERDer Schalter erlaubt das Aus- und Einschalten des Audio-Controllers
BEDIENUNGEN UND FUNKTIONEN
5) WAHLSCHALTER -6dBDer Wahlschalter erlaubt das Level des analogen Eingangs XLR [6] um 6 dB zu verringern und gleichzeitig das hohe Ausgangslevel der Mixer oder anderer Audio-Vorrichtungen auszugleichen Wenn der Balken des Signallevels der Eingaumlnge auf dem Display [1] immer auf Maximum steht zeigt dies an dass das Signallevel am Eingang hoch ist und es wird empfohlen die Daumlmpfung -6dB zu benutzenIm Menuuml Option ist es moumlglich zu kontrollieren ob der Wahlschalter aktiviert ist
6) STECKVERBINDER AM EINGANG A UND BAuf Leitungslinie ausgeglichene EingaumlngeSie koumlnnen auch XLR-Steckdosen aufnehmen
7) AUSGANG-STECKVERBINDER ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo UND ldquo6rdquoAuf Leitungslinie ausgeglichene Ausgaumlnge Sie koumlnnen auch XLR-Stecker aufnehmen
Darauf achten dass die Ausgaumlnge korrekt entsprechend der Einstellungen der einzelnen Kanaumlle an den Lautsprechern oder Verstaumlrkern angeschlossen sind um Schaumlden und Fehlfunktionen vorzubeugen
Abschnitt ldquoAESEBUrdquo
8) EINGANGS-STECKVERBINDER INZusaumltzlich zu den analogen Audio-Eingaumlngen wurde ein digitaler Audio-Eingang SPDIF-AESEBU (AES3) vorgesehen der uumlber das Setup-Menuuml ausgewaumlhlt werden kannDer Eingang erfordert einen ausgeglichenen Anschluss mit einem XLR-Steckverbinder mit einem verdrillten Kabel mit 3 Leitern von 110 Ohm
9) AUSGANGS-STECKVERBINDER OUTDieser Steckverbinder erlaubt das Audiosignal an den analogen oder digitalen Eingaumlngen oder Ausgaumlngen zu verteilen Die Quelle muss uumlber das Menuuml Option eingestellt werdenDer Anschluss muss demselben Standard des Eingang entsprechen [Ref 8]
Abschnitt ldquoRDNETrdquo
10) EINGANGS-STECKVERBINDER DATA INPUTSteckverbinder RJ45 fuumlr den Dateneingang
11) AUSGANGS-STECKVERBINDER DATA LINKSteckverbinder RJ45 fuumlr den Datenausgang Fuumlr die serielle Kaskaden-Verbindung
12) LEUCHTANZEIGE ONDiese gruumlne Anzeige leuchtet nur wenn AC26N uumlber den Computer mit der Haupteinheit RDNET verbunden ist und diese erkannt hat
13) LEUCHTANZEIGE ACTIVEDiese gelbe Anzeige blinkt wenn eine Datenuumlbertragung zwischen RDNET und der Vorrichtung aktiv ist
PUSH
P SHU
SHPU
P SHU
PUSH
ANSCHLUumlSSE
Analoge Audio-AnschluumlsseDie ausgeglichenen Anschluumlsse erlauben die Geraumlusche der Kabel auf ein Minimum zu verringern und so die Benutzung langer Kabel zuzulassenDiese Anschluumlsse koumlnnen sowohl an den Ein- als auch an den Ausgaumlngen benutzt werdenDer XLR-Steckverbinder muss mit Pin 1 an Masse Pin 2 am Pluspol (+) und Pin 3 am Minuspol (-) angeschlossen werden Bei einem abgeschirmten Kabel muss die Abschirmung an Pin 1 liegenDie Verbindungskabel XLR-XLR und XLR-Jack 14 (63 mm) koumlnnen fuumlr den Anschluss
12
3
Eingang
XLR weiblichen
Pin 3 = MinuspolErkaumlltungphase -VE
Pin 3 = MinuspolErkaumlltungphase -VE
1 2
3
Ausgang
XLR maumlnnlichen
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Ring
Schaft
Spitze = PluspolWaumlrmephase +VE
Ring = MinuspolErkaumlltungphase -VE
Schaft=SchirmMasse
Spitze
Die nicht ausgeglichenen Anschluumlsse koumlnnen auch benutzt werden wenn die Kabelgeraumlusche ansteigen und diese Kabel duumlrfen nicht laumlnger sein als 5 MeterDiese Anschluumlsse koumlnnen sowohl an den Ein- als auch an den Ausgaumlngen benutzt werdenDie nicht ausgeglichenen Anschluumlsse koumlnnen das Signallevel am Eingang um 6 dB verringern um dem vorzubeugen muss Pin 3 an Masse angeschlossen werden obwohl dies das Geraumlusch verstaumlrken kann
12
3
Eingang
XLR weiblichen
1 2
3
Ausgang
XLR maumlnnlichen
Spitze Schaft
Spitze = Signal
Schaft=SchirmMasse
Pin 3 = zu Pin 1 gebruumlckt
Pin 3 = zu Pin 1 gebruumlckt
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
31
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
32
Digitales Audio (AESEBU)AESEBU (Protokoll AES3) ist ein ausgeglichener und uumlber einen Transformator elektrisch isolierter Eingang Er erlaubt die Benutzung von zwei Kanaumllen an einem einzigen abgeschirmten bipolaren Kabel Das gedrillte Kabel muss 3-polig sein eine Impedanz von 100 Ohm haben und mit einem XLR-Steckverbinder (AES3 Standard) abgeschirmt sein
RdnetJeder Port RDNet an Control 2 und Control 8 kann an max 32 kompatiblen Vorrichtungen die in Kaskade geschaltet sind angeschlossen werden Im nachstehenden Beispiel ist der Port der Kontrolleinheit RDNET CONTROL 2 am Eingang DATA INPUT eines AC 26N angeschlossen dessen paralleler Ausgang DATA LINK zum Eingang des naumlchsten AC26N geht Im Beispiel ist [n] eine Nummer zwischen 3 und 32 (maximale Anzahl der anschlieszligbaren Vorrichtungen an nur einem Netz)
RJ 45
|1|2|3|4|5|6|7|8|
Die Gesamtlaumlnge des Kabels CAT5 eines Unternetzes kann NICHT laumlnger als 900 Meter sein
Der Steckverbinder muss wie folgt angeschlossen sein1 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio +) 2 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio -)3 ndash Verfuumlgbar fuumlr andere Funktionen (zB analoge Masse)4 ndash digitale Masse5 ndash digitale Masse6 ndash Verfuumlgbar fuumlr andere Funktionen (zB Versorgung)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
EINSCHALTEN
Beim Einschalten der Vorrichtung startet die Initialisierung die einige Sekunden lang dauert Auf dem Display wird das Modell das Logo und der Fortschrittsbalken der Ladung des Programms angezeigt
Nach der Initialisierung erscheint auf dem Display das Menuumlfenster Meters Um die Angaben im Detail zu erfahren beziehen Sie sich bitte auf das Kapitel BESCHREIBUNG DES MENUumlFENSTERS Meters
AC26N kann jetzt benutzt werden
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
MENUrsquo PRINCIPALE
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Die sechs Menuumls im Prozessor zeigen undoder konfigurieren die Systemparameter
Anzeige der Levels der Ein- und Ausgaumlnge Anzeige des benutzten Programms und dessen Status Mute schnell
Speicherung Speicherung und Eliminierung der Systemkonfigurationen
Auswahl der Ausgaumlnge je nach Eingangssignal
Konfiguration jedes einzelnen Kanals
Konfiguration der Schnittfrequenzen und der Filtertypen fuumlr jeden einzelnen Ausgang
Zuordnung der Ein- und Ausgaumlnge Kontrast des Displays Firmware-Version Eingaumlnge und andere Optionen
Das Menuuml und die einzelnen Optionen der Anzeige koumlnnen durch Drehen des Drehgriffes FUNKTIONS SELECTOR ( ) ausgewaumlhlt werden
Die Hauptmenuumls sind
Meters
Preset
Matrix
Ch Job
X-Over
Option
Um die Auswahl zu treffen muss der gewuumlnschte Parameter auswaumlhlt und der Drehgriff Push Enter( | ) gedruumlckt werdenDas selbe Verfahren muss fuumlr die Auswahl undoder die Aumlnderung der Optionen innerhalb der Menuumlpunkte angewendet werden
BESCHREIBUNG DES MENUumlFENSTERS Meters
Diese Seite erlaubt die Konfigurationen und den allgemeinen Status der Ein- und Ausgaumlnge der benutzten Programmversion dessen Status und die Steuerung des Systems anzuzeigen
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
KONFIGURATION UND ANZEIGE
Um in das Fenster des Hauptmenuumls zu gelangen muss die Taste Menuuml ( ) auf der Frontseite der Vorrichtung gedruumlckt werdenMit der Taste ESC ( ) kehrt man von jeder Seite des Menuumls auf die vorherige Seite zuruumlck
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
33
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
34
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziertBei den digitalen Eingangssignalen entspricht die Angabe A und B dem EingangDreht man den Drehgriff FUNCTIONS SELECTOR [2] durchlaumluft man zyklisch die Ein- und Ausgangskanaumlle und die Angabe Mute allgemein (d) der ausgewaumlhlte Kanal wird hervorgehoben
b) BALKEN FUumlR DAS KOMPRESIONSLEVELMUTE KANAL
SIGNALKOMPRESSIONDie Signalkompression wird durch das Gleiten des rechten Balkens von oben nach unten angezeigt
MUTE Jeder einzelne Kanal kann auf Mute gestellt werden Den Kanal auswaumlhlen und den Drehgriff Push Enter [2] druumlcken um die Aumlnderung des Status zu bestaumltigen Die Angabe des Kanals wird durch den Buchstaben M ersetzt und der Balken wird komplett hervorgehobenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werden
c) BALKEN DES SIGNALLEVELSDie Anzeige des Levels jedes einzelnen Kanals wird durch das Gleiten des linken Balkens angezeigt
d) MUTE ALLGEMEINEs ist moumlglich alle Ein- und Ausgaumlnge gleichzeitig auf Mute zu schalten Den Drehgriff FUNCTIONS SELECTOR drehen den Buchstaben M waumlhlen und dann den Drehgriff Push Enter druumlckenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werdenDie allgemeine Stummschaltung hat eine houmlhere Prioritaumlt als die Stummschaltung der einzelnen Kanaumlle
e) ANSTEUERUNGSARTENEs wird angezeigt wie AC26N benutzt wird undoder an welchen Vorrichtungen es angeschlossen ist
= Benutzung stand-alone Kein Anschluss an einer externen Vorrichtung
= Direkt am Netz RDnet und am Computer angeschlossen
= Uumlber USB-Kabel direkt am Computer angeschlossen
f) ANZEIGE DES STATUS DER EINSTELLUNGENHier wird angezeigt ob einer oder mehrere Parameter des geladenen Programms im Vergleich zur letzten Speicherung veraumlndert wurden
Original-Programm
Programm mit veraumlnderten Parametern
g) EINGESTELLTES PROGRAMMDie Nummer zeigt das vom System geladene und benutzte Programm in Bezug auf die Lokalisierung der Speicherung an Fuumlr weitere Details beziehen Sie sich bitte auf das Menuuml Preset
Local
NET
USB
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
BESCHREIBUNG DES MENUumlFENSTERS Ch Job
Dieses Fenster erlaubt die Anzeige der Konfiguration jedes einzelnen Kanals
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) SIGNALLEVELZeigt die Signalstaumlrke an Das Ansteigen der Signalintensitaumlt wird in Dezibel (dB) ausgedruumlckt Der Parameter kann zwischen -8000 dB und +2000 dB in Schritten von 001 dB ausgewaumlhlt werden Ein Anstieg von 6 dB ist fast gleich eine Verdoppelung in linearer Skala des Spannungswertes des SignalsBei einer Staumlrke von 0 dB wird das Signal verstaumlrkt waumlhrend es ein einer Staumlrke von weniger als 0 dB abgeschwaumlcht wird
c) VERZOumlGERUNG DES SIGNALS (DELAY)Das wiedergegebene Audio-Signal kann verzoumlgert werden um die akustische Ausrichtung zu erlauben Dies gleicht die verschiedenen Positionen der Lautsprecher bei der Installation und Klangwiedergabe aus und wird in mS ausgedruumlckt Der Parameter kann zwischen 00 mS und 729 mS in Schritten von 01mS ausgewaumlhlt werden
Um ein Audiosignal auszurichten kann folgende Formel benutzt werden
Verzoumlgerung = GAPx1000)344
Verzoumlgerung = mS (in Millisekunden ausgedruumlckt)GAP = Abstand des Lautsprechers vom Referenzpunkt (in Metern ausgedruumlckt)Klanggeschwindigkeit = 344 ms
d) MUTEJeder einzelne Kanal kann auf Mute gestellt werden Derselbe Befehl kann im Fenster des Menuumls Meters aktiviert werden PS Die al lgemeine Stummschaltung hat eine houmlhere Priori taumlt als die Stummschaltung der einzelnen Kanaumlle
e) PHASEErlaubt die Phasenrotation um 180deg zum EingangssignalDiese Rotation erlaubt vor Allem die Optimierung der niederen Frequenzen bei komplexen Installationen
f) ENTZERRUNGENDieser Befehl oumlffnet das Menuumlfenster fuumlr die Entzerrung des einzelnen Kanals Er wird vor Allem benutzt um eine oder mehrere Frequenzen zu korrigieren die gedaumlmpft oder verstaumlrkt werden muumlssen
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
35
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
36
AC26N verwaltet 12 Filter fuumlr jeden einzelnen Ein- und Ausgangskanal mit drei verschiedenen Konfigurationen- Equalizer PEQ (peaking equalizer) ist ideal um nur ein bestimmtes Frequenzband
zu identifizieren zu isolieren und zu korrigieren Es gehen alle Frequenzen durch aber nur die um die mittlere Frequenz steigt und sinkt um eine bestimmte Bandbreite und eine bestimmte Staumlrke
- Equalizer High-Shelf geht alle Frequenzen durch aber die Frequenzen uumlber der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
- Equalizer Low-Shelf geht alle Frequenzen durch aber die Frequenzen unter der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
f Nummerierung der 12 verfuumlgbaren Filter fuumlr diesen Ein- oder Ausgang1
f2 Es wird der Filtertyp angezeigt
Dis Ausgeschaltet (nicht vorhanden)
PEQ Peaking equalizer
Sh H Filter High-Shelf
Sh L Filter Low-shelf
Beispiele PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
ANMERKUNGDer Parameter Bw legt das Frequenzfeld neben der eingestellten Frequenz fest wo der Filter aktiviert wird je houmlher der Bw-Wert desto houmlher das Frequenzfeld (1Bw=1 Oktave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filter High-Shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filter Low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) KOMPRESSIONDieser Befehl oumlffnet das Menuumlfenster fuumlr die Kompression des einzelnen Kanals
g1) TresholdIdentifiziert die Schwelle an der das Kompressionsverhaumlltnis beginnt Der Basiswert 11
g2) RatioIdentifiziert das Kompressionsverhaumlltnis zwischen dem Ein- und Ausgangssignal
g3) Post Gain Attach Release HoldDiese Daten entsprechen dem Kompressionsverhaumlltnis das man erreichen moumlchte
Post Gain ist der Gewinn am AusgangAttack ist die Anschlusszeit Release ist die ReleasezeitHold ist die Beibehaltungszeit
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
BESCHREIBUNG DES MENUumlFENSTERS Preset
Dieses Fenster erlaubt bis zu 32 Konfigurationen im AC26N zu speichernDer Hersteller liefert das System mit einem voreingestellten Programm das auf Position 0 gespeichert ist und nicht uumlberschrieben werden kann
032 Es zeigt die Lokalisierung der Speicherung der KonfigurationDiese Nummer erscheint auch im Fenster Meters auf der Position (g) Das benutzte Programm kann jederzeit vom Benutzer angezeigt werden
Empty Preset Es ist der Name der der Nummer der Lokalisierung zugeordnet wird wenn keine Einstellung gespeichert ist (leer)
Local preset Es i s t de r Name de r de r Nummer de r Loka l i s i e rung zugeordnet wird wenn eine Konfiguration gespeichert wird
ANMERKUNG = Man kann eine Einstellung mit dem gewuumlnschten Namen mit max 16 Buchstaben nur speichern wenn man die Schnittstelle uumlber den Computer benutzt
Bei der Wahl eines Programms erscheint folgendes Fenster
Anzeige des Namens der dem Programm zugeordnet istUm auf die Anwendung einzuwirken stehen 3 Auswahlmoumlglichkeiten zur Verfuumlgung
Das Programm wird im Speicher des AC 26N gespeichert
Das Programm wird geloumlscht
Das Programm wird geladen und ist bereit fuumlr die Benutzung
Save
Del
Load
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
37
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
38
BESCHREIBUNG DES MENUumlFENSTERS X-Over
Dieses Fenster erlaubt fuumlr jeden Ausgang einen Bassdurchgangsfilter einen Hochdurchgangsfilter oder mittels Kombination von beiden einen Banduumlbergangsfilter zu waumlhlenDer Filter ist ein Linkwitz-Riley wo man die Neigung von 12 dBoct 24dBoct oder 48 dBoct und die entsprechende Schnittfrequenz auswaumlhlen kann
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) AUSGANGSKANAumlLE
Die Steckverbinder am Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) FILTER CROSSOVERDen Filter nach Bedarf waumlhlen Man kann folgendes auswaumlhlen
Dis Kein Filter aktiviert
HP Hochdurchgangsfilter nur den Teil des Audiosignals durchlassen der uumlber der Schnittfrequenz liegt
LP Bassdurchgangsfilter nur den Teil des Audiosignals durchlassen der unter der Schnittfrequenz liegt
Filter-Konfiguration Tiefpass Hochpass
Nichts Dis Dis
Hochpass HP Dis
Tiefpass Dis LP
Bandpass HP LP
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
c) DAumlMPFUNGSNEIGUNGDie Daumlmpfungsneigung des Audiosignals auf der Basis der Verringerung auswaumlhlen die man erreichen moumlchte Je houmlher die Daumlmpfungsneigung bei gleicher Schnittfrequenz desto groumlszliger ist die Signalauswahl Man kann folgendes waumlhlen
12 entsprechend 12 dboct
24 entsprechend 24 dboct
48 entsprechend 48 dboct
d) SCHNITTFREQUENZErlaubt die Durchgangsfrequenz der niederen Frequenzen (Bassdurchgangsfilter) oder der hohen Frequenzen (Hochdruchgangsfilter) einzustellenDie Auswahl des Schnitts bezieht sich auf die Wiedergabe die man erreichen moumlchteDie benutzte Maszligeinheit ist Hz
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
BESCHREIBUNG DES MENUumlFENSTERS Matrix
Erlaubt fuumlr jeden Ausgang das Eingangssignal zu waumlhlen das als Quelle benutzt werden soll
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) AUSGANGSKANAumlLEIdentifizierung des einzustellenden Ausgangskanals
b) IDENTIFIZIERUNG DER EINGAumlNGEDen Signaltyp auswaumlhlen der nach eigener Anforderung jedem einzelnen Ausgang zugeordnet werden soll Man kann folgendes waumlhlen
In A Das Signal wird dem Eingang A zugeordnet
In B Das Signal wird dem Eingang B zugeordnet
In A+B Zuordnung der a lgebra ischen Summe der be iden Eingangssignale A und B
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
BESCHREIBUNG DES MENUumlFENSTERS Option
Erlaubt die Anzeige der Systemeinstellungen wie die Zuordnung der Ein- und Ausgaumlnge Daumlmpfung Displaykontrast und Firmware-Version
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B Src
Diese Option erlaubt die Einstellung des Audio-Signaltyps am Eingang
Analoge Audiosignale (Eingaumlnge A und B)
Digitale Audiosignale (Eingang AESEBU)
DigOut Src
An In =Audiosignale an den analogen Eingaumlngen
Dig In =Audiosignale am digitalen Eingang
OUT 1-2 =Audiosignale an den Ausgaumlngen 1 und 2
OUT 3-4 =Audiosignale an den Ausgaumlngen 3 und 4
OUT 5-6 =Audiosignale an den Ausgaumlngen 5 und 6
Input Mode
An In
Dig In
Indip =
Linked =
Diese Option erlaubt die Audioquelle zu waumlhlen die fuumlr den Steckverbinder AESEBU OUT (digitaler Ausgang) bestimmt ist
Erlaubt die Eingaumlnge zu konfigurieren
Sie sind unabhaumlngig und selbststaumlndig sie unterliegen keinen Verpflichtungen untereinander Sie sind verbunden und funktionieren im Stereo-Modus
Die Kompressoren Filter Verzoumlgerungen die Lautstaumlrke sind bei beiden Kanaumllen identisch
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
39
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
40
Atten PadZeigt an wie der Wahlschalter -6 dB auf der Ruumlckseite eingestellt ist [Ref 5] Dieser Wahlschalter muss aktiviert werden wenn das Level an den analogen Eingaumlngen zu hoch ist Der Wahlschalter wird uumlber die Taste aktiviert im Menuuml gibt es nur eine Anzeige
0dB = Wahlschalter nicht aktiviert
-6dB = Wahlschalter aktiviert
Contrast
10 heller 60 dunkler 100
Fw Vers
Die Eingangssignale sind dieselben wie die Eingangsquelle
Die Eingangssignale werden vom internen Prozessor um -6 dB gedaumlmpft
Erlaubt den Kontrast des LCD-Displays einzustellen um den Unterschied der Helligkeit auf den Installationsort auszurichten Ein deutlicheres Display erlaubt auf korrekte und schnelle Weise innerhalb der Menuumls zu surfenDie Hersteller-Einstellung am Ausgang liegt bei 60
Zeigt die Firmware-Version des Prozessors an
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
41
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
42
TECHNISCHE DATEN
Antwort in FrequenzDynamische GammaCMMRCrosstalkDistorsion
ProzessorFrequenz der DatenausarbeitungAnaloge Converter Verzoumlgerung der VerteilungSpeicherung der Konfigurationen
DisplayTastenBedienungen
Analoger Eingang ndeg2 x XLR (3-poliger Female Stecker)Impedanz des Eingangs gt10KOhmMaximales Level +21dBu ohne PAD
+27dBu bei PAD
Impedanz des Ausgangs 50OhmMaximales Level +21dBu Typ symmetrisch
Typ SPDIF-AESEBU (AES3)
Typ Entsprechend dem Standard des Eingang
Typ
Typ
NETZSPANNUNGABMESSUNGEN (BXHXT)GEWICHT
AUDIO-LEISTUNGEN+- 01dB (20 to 30kHz)116dB typgt 60dB (50 to 10kHz)lt -100dB0002 (1kHz +4dBu)
DIGITALE AUDIO-LEISTUNGEN DSP 2856-bit 48KHz24-bit BURR BROWN15ms32 preset
KONTROLLEN LCD GrafikESC - MENU - FUNCTIONS SELECTIONENTER
EIN-AUSGAumlNGE
Analoger Ausgang ndeg6 x XLR (3-poliger Male Stecker)
Digitaler Eingang ndeg1x XLR (3-poliger female Stecker)
Digitaler Ausgang ndeg1x XLR (3-poliger Male Stecker)
Ein-Ausgang Rdnet ndeg2 x XLR RJ45 (kabel CAT 5) USB Typ B
KONTROLLPARAMETER AUDIOStaumlrke -80dB a +20dB step 01dBVerzoumlgerung Eingang 0 a 729mS step 01 mS
Ausgang 0 a 340mS step 01mSPhasenrotation 0deg - 180deg
KOMPRESSIONSchwelle -80dB a +20dB step 01dBVerhaumlltnis 11 a Inf1 step 001Staumlrke am Ausgang 0dB a 40dB step 01dBAnschlusszeit 1mS a 1000mS step 01mSReleasezeit 1mS a 1000mS step 01mSBeibehaltungszeit 1mS a 1000mS step 01mS
EQUALIZER12 Equalizer fuumlr jeden Ein- und Ausgang
PEQ (parametrischer) Hi-shelf Lo-sheftFrequenz 20Hz a 20KHz step 1HzStaumlrke -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (lediglich PEQ)
FILTER CROSSOVERFilter Linkwitz Riley
HP HochdurchgangsfilterLP Bassdurchgangsfilter
Neigung 12dBoct - 24dBoct - 48dBoctSchnittfrequenz 5Hz a 20KHz step 1Hz
Full-range 100-240Vac 50-60Hz430482x43x130mm 19Kg
AnmerkungenSpezifikationen unterliegen Aumlnderungen ohne Vorankuumlndigung
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
INTRODUCTIONAC26N est un processeur audio numeacuterique pour la gestion de leacutequipement audio conccedilu pour des installations fixes et mobiles Il fonctionne selon une technologie de pointe avec des processeurs agrave 2856bits et des convertisseurs ADDA agrave 24-bits hautes performances Les fonctions du processeur sont les niveaux dentreacutee et de sortie le deacutelai (delay) la polariteacute 12 bandes deacutegalisation par canal dentreacutee et de sortie diffeacuterentes seacutelections de croisement (crossover) et un limiteur hautes performances Le controcircle des filtres a une reacutesolution de 1Hz Les entreacutees et les sorties peuvent ecirctre programmeacutees en plusieurs configurations pour satisfaire tous les besoins AC26N peut ecirctre controcircleacute en temps reacuteel et tous les paramegravetres peuvent ecirctre configureacutes depuis le pupitre frontale et par ordinateur avec interface graphique intuitive accessible via le logiciel laquoDVA Networkraquo et une connexion de reacuteseau deacutedieacutee RDnet ou USBLa mise agrave jour du logiciel pour lUniteacute centrale et DSP par ordinateur portable permet de maintenir le dispositif actualiseacute Il est possible denregistrer et de rappeler 32 configurations preacute-eacutequipeacutees de configuration
Contenu de lemballage - AC26N - Mode demploi- CD logiciel- Cacircble dalimentation
Caracteacuteristiques- 2 entreacutees et 6 sorties avec adressage flexible- Entreacutee et sortie steacutereacuteo AESEBU adressables - DSP 2856-bit- Convertisseurs AD BURR BWOWN 24-bit hautes performances- Freacutequence de reacutesolution des filtres 1 Hz - 12 eacutegaliseurs parameacutetriques pour chaque entreacutee et sortie- 2 filtres de croisement par sortie avec pente seacutelectionnable agrave 122448dBoct- DRC agrave configuration multiple hautes performances pour configuration limiteur
compression pour chaque entreacutee et sortie- Niveau reacuteglable en dB polariteacute et deacutelai pour chaque entreacutee et sortie- Mise agrave jour du micrologiciel par lordinateur- Affichage graphique agrave cristaux liquides- 32 preacutereacuteglages enregistrables par lutilisateur- Interface USB pour le controcircle et la configuration par ordinateur- Interface RDnet permettant de controcircler jusquagrave 256 dispositifs agrave distance
PC
PC
RDNETcontrol(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FONCTIONS DE LA FACE AVANT
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
COMMANDES ET FONCTIONS1) AFFICHAGE
Laffichage graphique agrave cristaux liquides permet de visualiser et deacutediter les informations de lAC26N sans utiliser lordinateur Le contraste peut ecirctre configureacute dans le menu principal
2) MANETTE Functions Selector et Push EnterCe controcircle permet de se deacuteplacer de seacutelectionner et de modifier les paramegravetres dans les menus affichables agrave leacutecranRotation de la manette (Functions Selectors)- permet de se deacuteplacer sur les diffeacuterentes pages du menu - permet de modifier les paramegravetres seacutelectionneacutesPression de la manette (Push Enter)- permet de seacutelectionnervalider les paramegravetres
3) Bouton ESC Ce controcircle permet de quitter les menus afficheacutes ou de revenir agrave la visualisation preacuteceacutedente
4) Bouton Menu Ce controcircle permet dacceacuteder directement au menu principal
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
Fra
nccedilais
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
43
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
Fra
nccedilais
44
DVA Network
AC26N est eacutequipeacute dune interface de reacuteseau proprieacutetaire deacutenommeacutee RDNET au moyen de laquelle il est possible de sinterfacer agrave lordinateur agrave travers un peacuteripheacuterique (RDNET control)
Pour cela un protocole de communication a eacuteteacute deacuteveloppeacute avec lequel il est possible de recevoir et denvoyer les donneacutees ce branchement permet de faire le monitorage en temps reacuteel des paramegravetres du diffuseur comme puissance de sortie tempeacuterature de lamplificateur eacutetat du limiteur etc Il est aussi possible de seacutelectionner diffeacuterentes eacutegalisations ou den creacuteer de nouvelles et de reacutegler les niveaux de volume souhaiteacutes au moyen dun plug-in approprieacute
On conseille de teacuteleacutecharger gratuitement le logiciel DVA Network directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
DVA USB Manager
On conseille de teacuteleacutecharger gratuitement le logiciel DVA USB Manager directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
Le micrologiciel du module amplificateur peut ecirctre remis agrave jour par le port USBPour rendre cette mise agrave jour possible et facile un programme speacutecifique a eacuteteacute deacuteveloppeacute
DOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
CONNEXIONS DU PANNEAU ARRIEgraveRE
1586 75 141210 11 13 169 17
14) Connecteur ldquo USBrdquoCe connecteur USB (type B) permet de connecter le processeur agrave un ordinateur pour le controcircle et la mise agrave jour du micrologiciel via un programme deacutedieacute (DVA Network)
15) PRISE DALIMENTATION MAINSPermet la connexion du cacircble dalimentation fourni de seacuterie
16) PORTE-FUSIBLE FUSELogement pour fusible de ligne
17) INTERRUPTEUR GENERAL POWERLinterrupteur permet de mettre en marche ou deacuteteindre le controcircleur audio
COMMANDES ET FONCTIONS
5) SELECTEUR ldquo-6dBrdquoLe seacutelecteur permet de reacuteduire de 6dB les niveaux dentreacutee analogiques XLR [6] tout en compensant les niveaux eacuteleveacutes de sortie des meacutelangeurs ou dautres dispositifs audio Quand la barre du niveau de signal des entreacutees sur laffichage [1] reste au maximum cela indique que le niveau du signal entrant est eacuteleveacute Il est alors conseilleacute dutiliser latteacutenuation -6dBIl est possible de veacuterifier quand le seacutelecteur est activeacute par le menu Option
6) CONNECTEURS DENTREE ldquoArdquo ET ldquoBrdquoEntreacutees eacutequilibreacutees au niveau de la ligneIls sont en mesure daccepter des connecteurs XLR macircles
7) CONNECTEURS DE SORTIE ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo ET ldquo6rdquoSorties eacutequilibreacutees au niveau de la ligne Ils sont en mesure daccepter des connecteurs XLR femelles
Prendre garde agrave brancher convenablement les sorties sur les diffuseurs ou les amplificateurs en fonction des configurations de chaque canal pour eacuteviter des deacutegacircts et des problegravemes de fonctionnement
Section ldquoAESEBUrdquo
8) CONNECTEUR DENTREE INOutre les entreacutees audio analogiques une entreacutee audio numeacuterique SPDIF-AESEBU (AES3) a eacuteteacute preacutevue et peut ecirctre seacutelectionneacutee par le menu de setupLentreacutee requiert une connexion eacutequilibreacutee en utilisant un connecteur XLR avec un cacircble agrave 3 conducteurs de 110ohm torsadeacute
9) CONNECTEUR DE SORTIE OUTCe connecteur permet de relancer le signal audio dans les entreacutees analogiques ou numeacuteriques ou sur les sorties La source doit ecirctre reacutegleacutee par le menu OptionLa connexion sera conforme agrave la mecircme norme que lentreacutee [reacutef8]
Section ldquoRDNETrdquo
10) CONNECTEUR DENTREE DATA INPUTConnecteur RJ45 entreacutee de donneacutees
11) CONNECTEUR DE SORTIE DATA LINKConnecteur RJ45 sortie de donneacutees pour la connexion de seacuterie en cascade
12) VOYANT LUMINEUX ONCe voyant de couleur verte sallume uniquement quand lAC26N a reconnu et est connecteacute agrave luniteacute principale RDNET par lordinateur
13) VOYANT LUMINEUX ACTIVECe voyant de couleur jaune clignote quand une transmission des donneacutees est active entre RDNET et le dispositif
PUSH
P SHU
SHPU
P SHU
PUSH
CONNEXIONS
Audio analogiquesLes connexions eacutequilibreacutees permettent de reacuteduire au minimum le bruit provoqueacute par les cacircbles et dutiliser de longs cacircblesCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLe connecteur XLR doit ecirctre brancheacute avec la broche 1 agrave la masse la broche 2 au chaud (+) et la broche 3 au froid (-) En cas de cacircble blindeacute brancher le blindage agrave la broche 1Les cacircbles de connexion XLR-XLR et XLR-Jack14(63mm) peuvent semployer pour la connexion agrave lAC26N
12
3
Entreacutee
Entreacutee
XLR - femme
XLR - femme
1 2
3
Sortie
Sortie
XLR - Macircle
XLR - Macircle
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2 = Point chaudPhase +VE
Broche 3 =Point froidPhase -VE
Broche 3 =Point froidPhase -VE
Anneau
Manchon
Pointe Point chaudPhase +VE
Anneau = Point froidPhase -VE
ManchonB Masselindeacute
Pointe
Les connexions deacuteseacutequilibreacutees peuvent semployer mecircme si le bruit provoqueacute par les cacircbles augmente Les cacircbles ne peuvent deacutepasser 5m de longCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLes connexions deacuteseacutequilibreacutees peuvent abaisser le niveau du signal entrant de 6dB Pour remeacutedier agrave cet inconveacutenient il faut brancher la broche 3 agrave la masse mecircme si cela augmente le bruit
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
45
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
46
12
3
1 2
3
Pointe Manchon
Pointe = Signal
Broche 3 = Link to Pin 1
Broche 3 = Link to Pin 1
ManchonB Masselindeacute
Audio numeacuteriques (AESEBU)
AESEBU (protocole AES3) est une entreacutee eacutequilibreacutee isoleacutee eacutelectriquement agrave laide dun transformateur Elle permet demployer deux canaux audio dans un seul cacircble bipolaire blindeacute Les caracteacuteristiques du cacircble doivent ecirctre de 3 pocircles impeacutedance 100ohm torsadeacute et blindeacute avec connecteur XLR (AES3 standard)
RJ 45
|1|2|3|4|5|6|7|8|
RDnet
Chaque port RDNet des Control 2 et Control 8 peut ecirctre brancheacute agrave un maximum de 32 dispositifs compatibles placeacutes en cascade Dans lexemple suivant le port de luniteacute de controcircle RDNET CONTROL 2 est relieacute agrave lentreacutee DATA INPUT dun AC26N dont la sortie parallegravele DATA LINK est envoyeacutee agrave lentreacutee de lAC26N successif Dans lexemple [n] est un nombre compris entre 3 et 32 (limite maximale des dispositifs que lon peut relier agrave un sous-reacuteseau)
La longueur totale du cacircble CAT5 dun sous-reacuteseau NE peut PAS deacutepasser 900 megravetres
Le connecteur doit ecirctre relieacute comme 1 ndash disponible pour dautres fonctions (par exemple audio +) 2 ndash disponible pour dautres fonctions (par exemple audio )3 ndash disponible pour dautres fonctions (par exemple masse analogique)4 ndash masse numeacuterique5 ndash masse numeacuterique6 ndash disponible pour dautres fonctions (par exemple alimentation)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
MISE EN MARCHE
Lors de la mise en marche du dispositif linitialisation deacutebute et dure quelques secondes Leacutecran affiche le modegravele le logo et la barre de progression du chargement du programme
En fin de processus dinstallation leacutecran affiche la fenecirctre du menu Meters Pour connaicirctre les indications en deacutetail consulter le paragraphe DESCRIPTION FENETRE MENU Meters
LAC26N est precirct agrave lemploi
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION ET VISUALISATION
Pour entrer dans la fenecirctre du menu principal il faut pousser sur la touche MENU ( ) agrave lavant du dispositifDune page quelconque du menu en poussant sur la touche ESCrdquo ( ) on revient automatiquement sur la page-eacutecran preacuteceacutedente
MENU PRINCIPAL
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Le processeur contient six menus Ils montrent etou configurent les paramegravetres du systegravemeLes menus principaux sont
Meters Visualisation des niveaux des entreacutees et des sorties visualisation du programme utiliseacute et eacutetat mute rapide
Preset Meacutemoriser enregistrer et eacuteliminer les configurations du systegraveme
Matrix seacutelectionner les sorties en fonction du signal entrant
Ch Job configuration de chaque signal
X-Over configurer les freacutequences de coupure et les types de filtres pour chaque sortie
Option attribution des entreacutees et des sorties contraste daffichage la version du micrologiciel les entreacutees et dautres options
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
47
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
48
DESCRIPTION DE LA FENETRE MENU Metersrdquo
Cette fenecirctre permet de visualiser les configurations et leacutetat geacuteneacuteral des entreacutees et des sorties la version du programme utiliseacute son eacutetat et le mode de pilotage du systegraveme
Les menus et les options afficheacutees peuvent se seacutelectionner en tournant la manette ldquoFUNCTIONS SETECTORrdquo ( ) Pour avoir accegraves agrave linteacuterieur de la seacutelection il faut mettre le paramegravetre souhaiteacute en eacutevidence et pousser sur la manette ldquoPush Enterrdquo ( | ) Il faut en faire de mecircme pour seacutelectionner etou modifier les options dans les commandes du menu
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositifAvec des signaux dentreacutee numeacuteriques les indications ldquoArdquo et ldquoBrdquo correspondent agrave lentreacuteeEn tournant la manette ldquoFUNCTIONS SELECTORrdquo [2] on fait deacutefiler en mode cyclique les canaux dentreacutee de sortie et lindication de mute geacuteneacuteral (d) le canal seacutelectionneacute est mis en eacutevidence
b) BARRE DE NIVEAU DE COMPRESSIONMUTE CANAL
COMPRESSION DE SIGNALLa compression du signal est visualiseacutee par le deacutefilement de la barre de droite de haut en bas
MUTE Chaque canal peut ecirctre placeacute en mute Seacutelectionner le canal et pousser sur la manette ldquoPush Enterrdquo [2] pour valider le changement deacutetat Lindication du canal sera remplaceacutee par la lettre M et la barre sera totalement mise en eacutevidencePour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterations
c) BARRE DE NIVEAU DE SIGNALLindication du niveau de chaque canal est signaleacutee par le deacutefilement de la barre de gauche
d) MUTE GENERALIl est possible de mettre simultaneacutement toutes les entreacutees et les sorties en mute Tourner la manette ldquoFUNCTIONS SELECTORrdquo seacutelectionner la lettre M et pousser sur la manette Push EnterPour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterationsLe mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) MODES DE COMMANDEIl affiche le mode dutilisation etou les dispositifs qui sont relieacutes agrave lAC26N
Local = utilisation autonome Aucune connexion agrave un dispositif exteacuterieur
NET = relieacute directement au reacuteseau deacutedieacute RDNet et agrave lordinateur
USB = relieacute directement agrave un ordinateur par cacircble USB
f) INDICATION DETAT DE PARAMETRAGECette indication permet de constater si un ou plusieurs paramegravetre(s) du programme chargeacute aont eacuteteacute modifieacute(s) par rapport au dernier sauvetage
= programme dorigine
= programme avec des paramegravetres modifieacutes
g) PROGRAMME CONFIGURELe chiffre indique le programme chargeacute et utiliseacute par le systegraveme agrave lemplacement de sauvetage Consulter le menu de Preset pour de plus amples deacutetails
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
DESCRIPTION DE LA FENETRE MENU Ch Job
Cette fenecirctre permet dafficher la configuration de chaque canal
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) NIVEAU DU SIGNALIndique le gain du signal Laugmentation de lintensiteacute dun signal est libelleacutee en deacutecibel (dB) Le paramegravetre peut ecirctre seacutelectionneacute de -8000dB agrave +2000dB avec des pas de 001dB Une augmentation de 6dB est eacutegale approximativement au redoublement agrave leacutechelle lineacuteaire du niveau du signal sous tensionAvec un gain supeacuterieur agrave 0dB le signal est amplifieacute tandis quavec un gain infeacuterieur agrave 0dB le signal est atteacutenueacute
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
49
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
50
c) DELAI DU SIGNAL (DELAY)Le signal audio reproduit peut ecirctre retardeacute pour permettre lalignement acoustique Cela compense les diffeacuterentes positions des diffuseurs pendant linstallation et la reproduction sonore Il se libelle en mS Le paramegravetre peut ecirctre seacutelectionneacute de 00mS agrave 729mS avec un pas de 01mSPour aligner un signal audio il est possible dutiliser la formule suivante
Deacutelai = (GAPx1000)344
Deacutelai = ms (en millisecondes)GAP = distance du diffuseur du point de reacutefeacuterence (en megravetres)Vitesse du son = 344ms
d) MUTEChaque canal peut ecirctre placeacute en mute La mecircme commande peut ecirctre activeacutee dans la fenecirctre du menu meters NB Le mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) PhasePermet la rotation de phase de 180deg par rapport au signal entrantCette rotation permet loptimisation surtout des basses freacutequences dans les installations complexes
f) EGALISATIONCette commande ouvre la fenecirctre du menu deacutegalisation de chaque canal Elle sert surtout pour corriger une ou plusieurs freacutequences qui doivent ecirctre atteacutenueacutees ou augmenteacutees
M M
LAC26N gegravere 12 filtres par canal dentreacutee et sortie avec trois types de configurations diffeacuterentes - Leacutegaliseur PEQ (peaking equalizer) est ideacuteal pour identifier isoler et
corriger une seule plage de freacutequences bien deacutetermineacutee Toutes les freacutequences passent mais il augmente ou diminue uniquement celles autour de la freacutequence centrale pour une bande preacutecise et un gain deacutefini
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessus de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessous de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
f Numeacuterotation des 12 filtres disponibles pour cette entreacutee ou cette sortie1
f Le type de filtre est afficheacute 2
Dis Deacutesactiveacute (absent)
PEQ Peaking equlizer
Sh H Filtre high-shelf
Sh L Filtre high-shelf
Exemples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
REMARQUELe paramegravetre Bw deacutetermine le champ de freacutequences adjacent agrave la freacutequence configureacutee ougrave est activeacute le filtre Plus la valeur Bw est eacuteleveacutee plus vaste est le champ de freacutequences (1Bw=1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONCette commande ouvre la fenecirctre du menu de compression de chaque canal
g1) TresholdIdentifie le seuil ougrave commence le rapport de compression La valeur de base 11
g2) RatioIndique le rapport de conversion entre le signal entrant et le signal sortant
g3) Post Gain Attach Release HoldCes donneacutees deacutependent du rapport de conversion que lon veut obtenir - Post Gain est le gain de sortie- Attack est le temps dattaque - Release est le temps de relacircchement- Hold est le temps de maintien
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
52
DESCRIPTION DE LA FENETRE MENU Preset
Cette fenecirctre permet de meacutemoriser jusquagrave 32 configurations dans lAC26NLe fabricant fournit le systegraveme avec un programme configureacute et enregistreacute en position 0 et non susceptible deacutecrasement
032 Elle indique lemplacement de sauvetage de la configurationCe numeacutero apparaicirct dans la fenecirctre Meters en position (g) A tout moment le programme utiliseacute peut ecirctre afficheacute par lutilisateur
Empty Preset Cest le nom qui est associeacute au numeacutero de lemplacement quand aucune configuration (vide) nest enregistreacutee
Local preset Local preset est le nom qui est associeacute au numeacutero de lemplacement quand on enregistre une configuration NB = Il est possible denregistrer une configuration avec lenom souhaiteacute de 16 lettres tout au plus agrave condition que lonutilise linterface via lordinateur
Le nom du programme assigneacute est indiqueacutePour toucher agrave lapplication 3 choix soffrent agrave vous
Save Le programme est enregistreacute en meacutemoire de lAC26N
Del Le programme est effaceacute
Load Le programme est chargeacute et precirct agrave lemploi
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
51
DESCRIPTION DE LA FENETRE MENU X-Over
Cette fenecirctre permet de seacutelectionner un filtre passe bas un filtre passe haut ou par la combinaison des deux de creacuteer un filtre passe bande pour chaque sortieLe filtre actif est un Linkwitz-Riley qui permet de seacutelectionner la pente de 12dBoct 24dBoct ou 48dBoct et sa freacutequence de coupure
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) CANAUX DE SORTIE
Les connecteurs de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) FILTRE CROSSOVERSeacutelectionner le filtre selon les besoins Il est possible de seacutelectionner
Dis Aucun filtre activeacute
HP Filtre passe-haut laisse passer uniquement la partie de signal audio supeacuterieure agrave la freacutequence de coupure
LP Filtre passe-bas laisse passer uniquement la partie de signal audio infeacuterieure agrave la freacutequence de coupure
Configuration du filtre Passe-haut Passe-bas
Rien Dis Dis
Passe-haut HP Dis
Passe-bas Dis LP
Passe-bande HP LP
12dBoct
24dBoct
Hz
dB
Ga
in 48dBoct
12dBoct
24dBoct
Hz
dB
Ga
in
48dBoct
c) PENTE DATTENUATIONSeacutelectionner la pente datteacutenuation du signal audio en fonction de la diminution que lon veut obtenir Plus la pente datteacutenuation est eacuteleveacutee agrave eacutegaliteacute de freacutequence de coupure plus eacuteleveacutee sera la seacutelection du signal Il est possible de seacutelectionner
12 correspond agrave 12dboct
24 correspond agrave 24dboct
48 correspond agrave 48dboct
d) FREQUENCE DE COUPUREElle permet de reacutegler la freacutequence de passage des freacutequences infeacuterieures (filtre passe-bas) ou des freacutequences supeacuterieures (filtre passe-haut) uniquementLe choix de la coupure deacutepend de la reproduction que lon veut obtenirLuniteacute de mesure utiliseacutee est lHz
Hz
Hz
dB
dB
Ga
in
f0
f0
0dB0dB
0dB
-6dB
freacutequence
freacutequence
freacutequence
freacutequence
Ga
in
f0
0dB
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
53
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
54
DESCRIPTION DE LA FENETRE MENU Matrix
Elle permet de seacutelectionner le signal entrant agrave utiliser comme source pour chaque sortie
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) CANAUX DE SORTIEIdentification du canal sortant agrave reacutegler
b) IDENTIFICATIONS DES ENTREESSeacutelectionner le type de signal agrave associer agrave chaque sortie en fonction des besoins Il est possible de seacutelectionner
In A Le signal entrant A est associeacute
In B Le signal entrant B est associeacute
In A+B La somme algeacutebrique des deux signaux entrants A et B est associeacutee
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
DESCRIPTION DE LA FENETRE MENU Option
Permet dafficher les reacuteglages du systegraveme comme lassignation des entreacutees et des sorties latteacutenuation le contraste de laffichage et la version du logiciel
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcCette option permet de reacutegler le type de signal audio entrant
An In =signaux audio analogiques (entreacutees ldquoArdquo et ldquoBrdquo)
Dig In =signaux audio numeacuteriques (entreacutee AESEBU)
DigOut SrcCette option permet de seacutelectionner la source audio qui sera adresseacutee sur le connecteur AESEBU OUT (sortie numeacuterique)
An In = signaux audio des entreacutees analogiques
Dig In =signaux audio sur lentreacutee numeacuterique
OUT 1-2 = signaux audio sur les sorties 1 et 2
OUT 3-4 = signaux audio sur les sorties 3 et 4
OUT 5-6 = signaux audio sur les sorties 5 et 6
Input ModePermet de configurer les entreacutees
Indip = sont indeacutependantes et autonomes Ne sont soumises agrave aucun type de lien
Linked = sont unies et fonctionnent en mode steacutereacuteo Les compresseurs les filtres les deacutelais le volume sont identiques pour les deux canaux
Atten PadIndique le mode de reacuteglage du seacutelecteur ldquo-6dBrdquo placeacute agrave larriegravere [reacutef 5] Il faut activer ce seacutelecteur quand les niveaux dentreacutee analogiques sont trop eacuteleveacutes Le seacutelecteur sactive uniquement par le bouton Dans le menu il sagit dune simple visualisation
0dB = seacutelecteur non activeacute Les signaux dentreacutee sont identiques agrave la source entrante
-6dB = seacutelecteur activeacute Les signaux entrants sont atteacutenueacutes de -6dB par le processeur interne
ContrastIl permet de reacutegler le contraste de laffichage agrave cristaux liquides pour compenser la diffeacuterence de luminositeacute avec le lieu dinstallation Une plus grande clarteacute de laffichage permet de naviguer convenablement et rapidement dans les menusLe reacuteglage agrave la sortie de lusine du fabricant est de 60
10 plus clair 60 plus fonceacute 100
Fw VersIndique la version du logiciel du processeur
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
55
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
56
DONNES TECHINIQUES
PERFORMANCES AUDIOReacuteponse en freacutequence +- 01dB (20 to 30kHz)Plage dynamique 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsion 0002 (1kHz +4dBu)
PERFORMANCES AUDIO NUMERIQUES Processeur DSP 2856-bit Freacutequence de traitement des donneacutees 48KHzConvertisseurs analogiques 24-bit BURR BROWNDeacutelai de propagation 15msMeacutemorisations des configurations 32 preset
CONTROLES Affichage LCD graficoBoutonsCommandes ESC - MENU - FUNCTIONS SELECTION
ENTERENTREESSORTIESEntreacutee analogique ndeg2 x XLR (3 broches femelle)
Impeacutedance dentreacutee gt10KOhmNiveau maximum +21dBu senza PAD
+27dBu con PADSortie analogique ndeg6 x XLR (3 broches macircle )
Impeacutedance de sortie 50OhmNiveau maximum +21dBuType Balanceacute
Entreacutee numeacuterique ndeg1x XLR (3 broches femelle)Type SPDIF-AESEBU (AES3)
Sortie numeacuterique ndeg1x XLR (3 broches macircle )Type conforme agrave la norme de lentreacutee
EntreacuteesSortie Rdnet ndeg2 x XLR RJ45 (cacircble CAT 5)USB Type B
PARAMETRES DE CONTROLE DU SONGain -80dB a +20dB eacutetape 01dBDeacutelai Entreacutee 0 a 729mS eacutetape 01 mS
Sortie 0 a 340mS eacutetape 01mSRotation de phase 0deg - 180deg
COMPRESSIONSeuil -80dB a +20dB eacutetape 01dBRapport 11 a Inf1 eacutetape 001Gain agrave la sortie 0dB a 40dB eacutetape 01dBTemps dattaque 1mS a 1000mS eacutetape 01mSTemps de relacircchement 1mS a 1000mS eacutetape 01mSTemps de maintien 1mS a 1000mS eacutetape 01mS
EGALISEURS12 eacutegaliseurs pour chaque entreacutee et sortieType PEQ (parameacutetrique) Hi-shelf Lo-sheft
Freacutequence 20Hz a 20KHz eacutetape 1HzGain -30dB a +15dB eacutetape 001dBBande 005dB a 2dB eacutetape 001dB (uniquement pour PEQ)
FILTRES CROSSOVERFiltre Linkwitz Riley
Type HF high-shelfLF low-shelf
Pente 12dBoct - 24dBoct - 48dBoctFreacutequence de coupure 5Hz a 20KHz eacutetape 1Hz
ALIMENTATION Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)POIDS 19Kg
Remarques Speacutecifications sujettes agrave modifications sans preacuteavis
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
2 VIE ATTIVO2 WAY ACTIVE
3 VIE PASSIVO3 WAY PASSIVE
L
L
A
A
HIGH L
MID L
LOW HIGHMID RHIGHMID L
LOW L
HIGH R
MID R
LOW R
R
R
B
B
1
1
2
2
3
3
456
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
Menu Matrix configurationMatrix
57 58
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
EROUIG ATRIX TNM
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
OU
TP
UT
1
OU
TP
UT
2
OU
TP
UT
3
OU
TP
UT
4
OU
TP
UT
5
OU
TP
UT
6
AE
S-E
BU
OU
TP
UT
INP
UT
A
AE
S-E
BU
INP
UT
INP
UT
B
D D D D D D
D D
A A A A A A
A SA
MP
LE
RA
TE
CO
NV
A
LIN
KA
BL
E
SC
HE
MA
A B
LO
CC
HI -
BL
OC
K D
IAG
RA
MB
LO
CK
SC
HA
LT
BIL
D -
SC
HE
MA
S F
ON
CT
ION
NE
LS
LINE ARRAY SUB MONO ATTIVO
LINE ARRAY SUB MONO ACTIVEINGRESSI - INPUT
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
L
L
L
A
A
A
AESEBU IN
AESEBU IN
AESEBU IN
AESEBU OUT
AESEBU IN
AESEBU IN
AESEBU OUT
R
R
R
LR
B
B
B
123456
HIGHMID L
HIGHMID L HIGHMID R
HIGHMID R
LOW L LOW R
LAYER
DISPLAY MEMORY
FADER MODE
LAYER
DISPLAY MEMORY
FADER MODE
Ingresso ANALOGICO
ANALOG Input
Collegamento in cascata
Link connections
Ingresso DIGITALE
DIGITAL inputA B
BALANCED AUDIO INPUTS
-6dB
PUSH PUSH
IN OUT
AES EBUPUSH
Oppure
or
Oppure
or
Menu Option configurationOption
Menu Option configurationOption Menu Option configurationOption
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type Analog
AES out An In
Input type Analog
AES out An In
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
59 60
InA-B Src Dig InInA-B Src Dig InInA-B Src An InInA-B Src An In
frequenzaHz
dB
Gu
ad
ag
no
60 200 2800
0dB0dB
-6dB
Esempio di un sistema a 3-vie
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
Out 1 Out 2 Out 3
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Esempio di un sistema a 3-vie
61 62
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
26NAC 26NAC
R TE
DO
R
MO LEU O R CE S
E O TR L A
S O
O C ND I P
P hsuernE t
o su cti nF nel rS e tc o
E CSME UN
IGCHTE OL SN EOBd
ocaL l
M
0
484
467
430
44
31
75
12
7
DIMENSIONI DIMENSIONSABMESSUNGEN DIMENSIONS
a) INPUT AND OUTPUT CHANNELSThe input and output connectors are identified by the same information provided on the screen printing located on the device rear sideWith digital input signals the indications A and B concern the inputBy rotating the knob FUNCTION SELECTOR [2] input channels output channels and general muting indications are cyclically scrolled (d) the selected channel is highlighted
b) BAR COMPRESSION LEVEL CHANNEL MUTING
SIGNAL COMPRESSIONSignal compression is displayed by the vertical scrolling (top to down) of the right bar
MUTE Each channel can be individually muted Select the channel and press the Push Enter knob [2] to confirm the change of status The indication of the channel will be replaced by the letter M and the bar will be completely highlightedTo restore normal operation repeat the actions described above
c) SIGNAL LEVEL BARThe level indication for each channel is provided by scrolling the left bar
d) GENERAL MUTINGIt is possible to mute all the inputs and outputs simultaneously Rotate the knob FUNCTION SELECTOR select the letter M and press the Push Enter knobTo restore normal operation repeat the actions described aboveThe general mute has the highest priority with respect to the muting of individual channels
e) CONTROL MODEIt shows how the AC26N is used andor to which devices it is connected
Local = stand-alone usage No connection to an external device
NET = directly connected to dedicated RDnet network and to computer
USB = directly connected to another computer via USB cable
f) SETTING STATUS INDICATIONThis indication shows if the loaded program was amended in one or more parameters with respect to the last saving operation
= original program
= program with modified parameters
g) SET PROGRAMThe number shows the program that is loaded and used by the system with reference to the saving position Refer to the ldquoPresetrdquo menu for further details
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
MENU DESCRIPTION - CH JOB
This window allows to view the configuration of each individual channel
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) INPUT AND OUTPUT CHANNELSThe input and output connectors are identified by the same information provided on the screen printing located on the device rear side
b) SIGNAL LEVELIt shows the signal gain The increased signal intensity is expressed in decibels (dB) Such parameter can be selected in the range from -8000 dB to +2000 dB in steps of 001 dB An increase of 6 dB is approximately equal to doubling - in a linear scale - the signal voltage levelIf the gain exceeds 0 dB the signal is amplified while if the gain is lower than 0 dB the signal is attenuated
c) SIGNAL DELAYThe reproduced audio signal may be delayed to perform an acoustic alignment This compensates for the different positions of the speakers during the installation and the sound reproduction it is expressed in ms The parameter can be selected in the range from 00 ms to 729 ms in steps of 01 msThe following formula can be used to align an audio signal
Delay = (GAPx1000)344
Delay = ms (in milliseconds)GAP = distance between speaker and reference point (in meters)Speed of sound = 344 ms
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
22
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
21
d) MUTEEach channel can be individually muted The same command can be activated in the Meters Menu
NOTE The general mute has the highest priority with respect to the muting of individual channels
e) PhaseIt performs a phase rotation of 180deg with respect to the input signalSuch phase rotation allows the optimization in special way for low frequencies in complex installations
M M
f) EQUALIZATIONThis control opens the menu controlling the single channel equalization It is mainly used to correct one or more frequencies that must be reduced or increased
The AC26N manages 12 filters for each individual channel input and output with three different kinds of configuration
- PEQ Equaliser (peaking equalizer) ideal to identify isolate and correct only a certain range of frequencies All frequencies pass only those around the centre frequency are increased and decreased for a given bandwidth and set gain
- High-shelf Equalizer All frequencies pass but frequencies above the selected cut-off frequency are increased or attenuated by the given gain
- Low-shelf Equalizer All frequencies pass but frequencies below the selected cut-off frequency are increased or attenuated by the given gain
f Numbering of the 12 available filters for the specific input or output1
f Displays the kind of filter2
Dis Switched off (not present)
PEQ Peaking equlizer
Sh H High-shelf Filter
Sh L Low-shelf Filter
Examples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
NOTE
The parameter Bw defines the range of frequencies close to the set frequency where the filter is activated the greater the value of Bw the wider is the frequencies range (1 Bw = 1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONThis control opens the menu controlling the compression for the single channel
g1) ThresholdIdentifies the starting threshold for the compression ratio Base value 11
g2) RatioIndicates the conversion ratio between input and output signal
g3) Post Gain Attach Release HoldThese data are in function of the conversion ratio to achieve Post Gain is the output gain Attack is the attack time Release is the release time Hold is the holding time
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
24
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
23
MENU DESCRIPTION - PRESET
This window allows to store up to 32 configurations in the AC26NThe manufacturer provides the system with a program set and saved in position 0 that is not possible to overwrite
032 Indicates the location where the configuration is savedThis number also appears in the window Meters in position (g) The program in use can be displayed at any time by the user
Empty Preset It is the name associated with the location number when no setting is saved (empty)
Local preset It is the name associated with the location number when a setting is saved NOTE = It is possible to save a setting with the desired name up to 16 letters only via the computer interface
When a program is selected the following window is displayed
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
The name of the assigned program is displayed3 possible choices are available when working on the application
Save The program is saved in the AC 26N memory
Del The program is deleted
Load The program is loaded and ready to be used
MENU DESCRIPTION - X-OVER
This window allows to select for each output a low pass filter a high pass filter or create a band-pass filter via the combination of bothThe available filter is a Linkwitz-Riley where it is possible to select slopes of 12 dBoct 24 dBoct or 48 dBoct and their cut-off frequency
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) OUTPUT CHANNELS
The output connectors are identified by the same information provided on the screen printing located on the device rear side
b) CROSSOVER FILTERSelect the filter according to needs It is possible to select
Dis No filter enabled
HP High-pass filter set it to allow only the part of audio signal above the cut-off frequency
LP Low-pass filter set to allow only the part of audio signal below the cut-off frequency
Filter configuration Low-pass High-pass
Nothing Dis Dis
High-pass HP Dis
Low-pass Dis LP
Band-pass HP LP
12dBoct
24dBoct
Hz
dB
48dBoct
12dBoct
24dBoct
frequency
frequency
frequency
frequency
Hz
dB
48dBoct
c) ATTENUATION SLOPESelect the attenuation slope of the audio signal on the basis of the desired attenuation The higher the attenuation slope at the same cut-off frequency the greater the signal selection It is possible to select
12 equal to 12 dBoct
24 equal to 24 dBoct
48 equal to 48 dBoct
d) CUT-OFF FREQUENCYTo set the passing frequency for the lower frequencies only (low-pass filter) or the higher frequencies only (high-pass filter)The choice of the cut-off depends on the desired sound reproductionThe unit of measurement used is Hz
Hz
Hz
dB
dB
Ga
inG
ain
Ga
inG
ain
f0
f0
0dB0dB
0dB
-6dB
-6dB
0dB
0dB
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
26
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
25
MENU DESCRIPTION - MATRIX
For each output it allows to select the input signal to use as the source
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) OUTPUT CHANNELSIdentification of the output channel to set
b) IDENTIFICATIONS OF THE INPUTSIt selects the type of signal to match each output as needed It is possible to select
In A Associated with the input signal ldquoArdquo
In B Associated with the input signal ldquoBrdquo
In A+B Associated with the algebraic sum of the two input signals ldquoArdquo and ldquoBrdquo
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
MENU DESCRIPTION - OPTION
Allows to display the system settings such as the allocation of the inputs and outputs attenuation display contrast and firmware version
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcThis option allows to set the type of input audio signal
An In = Analog audio signals (inputs A and B)
DigIn = Digital audio signals (AESEBU input)
DigOut SrcThis option allows to select the audio source that will be forwarded to the connector AESEBU OUT (digital output)
An In = Audio signals available at analog inputs
Dig In = Audio signals available at digital inputs
OUT 1-2 = Audio signals available on outputs 1 and 2
OUT 3-4 = Audio signals available on outputs 3 and 4
OUT 5-6 = Audio signals available on outputs 5 and 6
Input ModeIt allows to configure the inputs
Indip = They are independent not subject to constraints of any kind between them
Linked = They are connected and work in stereo mode Compressors filters delays volume are identical for the two channels
Atten PadIt shows how to set the -6 dB switch located on the rear side [Ref 5] It is necessary to activate this selector when the analog input levels are too high The selector can be activated only by means of the button the menu is for display only
0 dB = Selector not activated The input signals are the same as the input source
-6 dB = Selector activated The input signals are attenuated by -6 dB with reference to the inner
processor
ContrastAllows to adjust the LCD display contrast to compensate for the brightness difference at the installation sites Greater display brightness allows to navigate correctly and quickly within the menuThe manufacturer output setting is 60
10 More bright 60 More dark 100
Fw VersIt shows the processor firmware version
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
28
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
27
TECHINICAL SPECIFICATION
AUDIO PERFORMANCEFrequency Response +- 01dB (20 to 30kHz)Dynamic Range 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistortion 0002 (1kHz +4dBu)
DIGITAL AUDIO PERFORMANCE Processor DSP 2856-bit Data processing Frequency 24-bit BURR BROWNAnalog converters 24-bit BURR BROWNPropagation Delay 15msStoring configurations 32 preset
CONTROLS Display LCD graficoButtonsControls ESC - MENU - FUNCTIONS SELECTION
ENTERINPUTSOUTPUTSAnalog Input ndeg2 x XLR (3 pole female)
Input impedance gt10KOhmMaximum Level +21dBu senza PAD
+27dBu con PADAnalog Output ndeg6 x XLR (3 pole male)
Output impedance 50OhmMaximum Level +21dBu Type Balanced
Digital Input ndeg1x XLR (3 pole female)Type SPDIF-AESEBU (AES3)
Digital Output ndeg1x XLR (3 pole male)Type Compliant with the input standard
RDnet InputsOutput ndeg2 x XLR RJ45 (CAT 5 cable)USB Tipo B
SOUND CONTROL PARAMETERSGain -80dB a +20dB step 01dBDelay
Input 0 a 729mS step 01 mSOutput 0 a 340mS step 01mSPhase Rotation 0deg - 180deg
COMPRESSIONThreshold -80dB a +20dB step 01dBRatio 11 a Inf1 step 001Output gain 0dB a 40dB step 01dBAttack time 1mS a 1000mS step 01mSRelease time 1mS a 1000mS step 01mSHold time 1mS a 1000mS step 01mS
EQUALIZERS12 equalizers for each input and outputType PEQ (parametrico) Hi-shelf Lo-sheft
Frequency 20Hz a 20KHz step 1HzGain -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (only with PEQ)
CROSSOVER FILTERSFilter Linkwitz Riley
Type HP High-pass LP Low-pass
Slope 12dBoct - 24dBoct - 48dBoctCUT-OFF FREQUENCY 5Hz a 20KHz passo 1Hz
POWER SUPPLY Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)
1719x17x51 inch (WxHxD)WEIGHT 19Kg
(42 lbs)Note Specifications subject to change without notice
EMI CLASSIFICATIONAccording to the standards EN 55103 this equipment is designed and suitable to operate in E3 (or lower E2 E1) Electromagnetic environments
EINLEITUNG
Verpackungsinhalt
Eigenschaften
AC26N ist ein digitaler Audio-Prozessor fuumlr die Verwaltung von Audio-Systemen der fuumlr feste und mobile Installationen entwickelt wurde AC26N benutzt die modernste Technologie mit 2856 bit-Prozessoren und 24-bit-ADDA-Wandlern mit hoher Leistungsfaumlhigkeit Die verfuumlgbaren Funktionen des Prozessors sind Ein- und Ausgangsstufen Verzoumlgerung (delay) Polaritaumlt 12 Equalizer-Frequenzen fuumlr Ein- und Ausgangskanal viele Crossover-Wahlmoumlglichkeiten und Limiter mit hoher Leistung Die Filter-Kontrolle hat eine Aufloumlsung von 1 Hz Die Ein- und Ausgaumlnge koumlnnen mit unterschiedlichen Einstellungen geregelt werden um allen Anforderungen gerecht zu werden AC26N kann in Echtzeit kontrolliert werden und jeder Parameter kann am Frontpaneel und vom Computer mit intuitiver graphischer Schnittstelle mittels Software DVA Network zugaumlnglich und einer Netzverbindung RDnet oder uumlber USB eingestellt werdenDie SW-Aktualisierung fuumlr CPU und DSP uumlber PC erlaubt die Vorrichtung auf dem aktuellen Stand zu halten Man kann 32 vorgesehene Konfigurationen speichern und aufrufen
- AC26N - Bedienungsanleitung- Software-CD- Versorgungskabel
- 2 Ein- und 6 Ausgaumlnge mit flexibler Adressierung- Adressierbarer Stereo-Ein- und Ausgang AESEBU - DSP 2856-bit- AD-Wandler BURR BROWN 24-bit mit hoher Leistungsfaumlhigkeit- Aufloumlsungsfrequenz der Filter 1 Hz - 12 parametrische Equalizer fuumlr jeden Ein- und Ausgang- 2 Crossover-Filter fuumlr jeden Ausgang mit auswaumlhlbarer Neigung 122448dBoct- DRC Multikonfiguration mit hoher Leistungsfaumlhigkeit fuumlr die Konfiguration des
Limitersder Kompression jedes Ein- und Ausgangs- Einstellbare dB-Stufe Polaritaumlt und Verzoumlgerung (delay) fuumlr jeden Ein- und Ausgang- Firmware-Aktualisierung uumlber PC- Graphisches LCD-Display- 32 Voreinstellungen vom Benutzer einstellbar- USB-Schnittstelle fuumlr die Kontrolle und Konfiguration mit dem Computer- Schnittstelle RDnet welche erlaubt bis zu 256 fern liegende Vorrichtungen
zu kontrollieren
PC
PC
RDNET control(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FUNKTIONEN VORDERSEITE
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
BEDIENUNGEN UND FUNKTIONEN
1) DISPLAYDas graphische LCD-Display erlaubt die Informationen des AC26N ohne einen Computer zu benutzen anzuzeigen und zu editieren Der Kontrast kann im Hauptmenuuml eingestellt werden
2) DREHGRIFF Functions Selector UND Push EnterDiese Kontrolle erlaubt sich in den Menuumls auf dem Display zu bewegen und die Parameter auszuwaumlhlen und zu veraumlndernDrehung des Drehgriffes (Functions Selectors)- Man kann sich innerhalb der verschiedenen Menuumlseiten bewegen- Erlaubt die Veraumlnderung der ausgewaumlhlten ParameterDruck des Drehgriffes (Push Enter)- Erlaubt die AuswahlBestaumltigung der Parameter
3) Taste ldquoESCrdquo Diese Kontrolle erlaubt die angezeigten Menuumls zu verlassen oder zur vorherigen Anzeige zuruumlckzukehren
4) Taste ldquoMenuumlrdquo Diese Kontrolle erlaubt den direkten Zugang zum Hauptmenuuml
Deuts
chD
euts
chB
ed
ien
un
gsan
leit
un
gB
ed
ien
un
gsan
leit
un
g
29
Deuts
chD
euts
chB
ed
ien
un
gsan
leit
un
gB
ed
ien
un
gsan
leit
un
g
30
DVA USB Manager
Die Firmware des Verstaumlrkermoduls kann uumlber den USB-Anschluss aktualisiert werdenUm diesen Vorgang zu ermoumlglichen und zu vereinfachen wurde ein dediziertes Programm entwickelt das beim Hersteller angefordert und auf einen Computer installiert werden muss
Wir empfehlen die Software DVA USB Manager direkt von der Webseite dB Technologies (wwwdbtechnologiescom) im Abschnitt laquoSoftware amp Controllerraquo herunterzuladen
DVA Network
AC26N ist mit einer eigenen als RDNET bezeichneten Netzschnittstelle ausgestattet dank der es uumlber ein Interface (RDNET Control) an einen Computer angeschlossen werden koumlnnenHierzu wurde ein Kommunikationsprotokoll entwickelt mit dem die Daten empfangen und gesendet werden Dank dieser Verbindung koumlnnen die Lautsprecherparameter wie Ausgangsleistung Verstaumlrkertemperatur Limiterstatus usw in Echtzeit kontrolliert werden Auszligerdem koumlnnen verschiedene Entzerrungen ausgewaumlhlt bzw neue erstellt werden oder die gewuumlnschte Lautstaumlrke eingestellt werden
Wir empfehlen die Software DVA_Network direkt von der Webseite dB Technologies (wwwdbtechnologiescom) im Abschnitt laquoSoftware amp Controllerraquo herunterzuladenDOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
RUumlCKWANDANSCHLUumlSSE
1586 75 141210 11 13 169 17
14) USB-SteckverbinderDieser USB-Steckverbinder (Typ B) erlaubt den Prozessor an einem Computer anzuschlieszligen um die Firmware mit dem speziellen Programm (DVA Network) zu kontrollieren und zu aktualisieren
15) STROMANSCHLUSS MAINSErlaubt den Anschluss des mitgelieferten Versorgungskabels
16) SICHERUNGSTRAumlGER FUSEAufnahme fuumlr die Netz-Sicherung
17) HAUPTSCHALTER POWERDer Schalter erlaubt das Aus- und Einschalten des Audio-Controllers
BEDIENUNGEN UND FUNKTIONEN
5) WAHLSCHALTER -6dBDer Wahlschalter erlaubt das Level des analogen Eingangs XLR [6] um 6 dB zu verringern und gleichzeitig das hohe Ausgangslevel der Mixer oder anderer Audio-Vorrichtungen auszugleichen Wenn der Balken des Signallevels der Eingaumlnge auf dem Display [1] immer auf Maximum steht zeigt dies an dass das Signallevel am Eingang hoch ist und es wird empfohlen die Daumlmpfung -6dB zu benutzenIm Menuuml Option ist es moumlglich zu kontrollieren ob der Wahlschalter aktiviert ist
6) STECKVERBINDER AM EINGANG A UND BAuf Leitungslinie ausgeglichene EingaumlngeSie koumlnnen auch XLR-Steckdosen aufnehmen
7) AUSGANG-STECKVERBINDER ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo UND ldquo6rdquoAuf Leitungslinie ausgeglichene Ausgaumlnge Sie koumlnnen auch XLR-Stecker aufnehmen
Darauf achten dass die Ausgaumlnge korrekt entsprechend der Einstellungen der einzelnen Kanaumlle an den Lautsprechern oder Verstaumlrkern angeschlossen sind um Schaumlden und Fehlfunktionen vorzubeugen
Abschnitt ldquoAESEBUrdquo
8) EINGANGS-STECKVERBINDER INZusaumltzlich zu den analogen Audio-Eingaumlngen wurde ein digitaler Audio-Eingang SPDIF-AESEBU (AES3) vorgesehen der uumlber das Setup-Menuuml ausgewaumlhlt werden kannDer Eingang erfordert einen ausgeglichenen Anschluss mit einem XLR-Steckverbinder mit einem verdrillten Kabel mit 3 Leitern von 110 Ohm
9) AUSGANGS-STECKVERBINDER OUTDieser Steckverbinder erlaubt das Audiosignal an den analogen oder digitalen Eingaumlngen oder Ausgaumlngen zu verteilen Die Quelle muss uumlber das Menuuml Option eingestellt werdenDer Anschluss muss demselben Standard des Eingang entsprechen [Ref 8]
Abschnitt ldquoRDNETrdquo
10) EINGANGS-STECKVERBINDER DATA INPUTSteckverbinder RJ45 fuumlr den Dateneingang
11) AUSGANGS-STECKVERBINDER DATA LINKSteckverbinder RJ45 fuumlr den Datenausgang Fuumlr die serielle Kaskaden-Verbindung
12) LEUCHTANZEIGE ONDiese gruumlne Anzeige leuchtet nur wenn AC26N uumlber den Computer mit der Haupteinheit RDNET verbunden ist und diese erkannt hat
13) LEUCHTANZEIGE ACTIVEDiese gelbe Anzeige blinkt wenn eine Datenuumlbertragung zwischen RDNET und der Vorrichtung aktiv ist
PUSH
P SHU
SHPU
P SHU
PUSH
ANSCHLUumlSSE
Analoge Audio-AnschluumlsseDie ausgeglichenen Anschluumlsse erlauben die Geraumlusche der Kabel auf ein Minimum zu verringern und so die Benutzung langer Kabel zuzulassenDiese Anschluumlsse koumlnnen sowohl an den Ein- als auch an den Ausgaumlngen benutzt werdenDer XLR-Steckverbinder muss mit Pin 1 an Masse Pin 2 am Pluspol (+) und Pin 3 am Minuspol (-) angeschlossen werden Bei einem abgeschirmten Kabel muss die Abschirmung an Pin 1 liegenDie Verbindungskabel XLR-XLR und XLR-Jack 14 (63 mm) koumlnnen fuumlr den Anschluss
12
3
Eingang
XLR weiblichen
Pin 3 = MinuspolErkaumlltungphase -VE
Pin 3 = MinuspolErkaumlltungphase -VE
1 2
3
Ausgang
XLR maumlnnlichen
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Ring
Schaft
Spitze = PluspolWaumlrmephase +VE
Ring = MinuspolErkaumlltungphase -VE
Schaft=SchirmMasse
Spitze
Die nicht ausgeglichenen Anschluumlsse koumlnnen auch benutzt werden wenn die Kabelgeraumlusche ansteigen und diese Kabel duumlrfen nicht laumlnger sein als 5 MeterDiese Anschluumlsse koumlnnen sowohl an den Ein- als auch an den Ausgaumlngen benutzt werdenDie nicht ausgeglichenen Anschluumlsse koumlnnen das Signallevel am Eingang um 6 dB verringern um dem vorzubeugen muss Pin 3 an Masse angeschlossen werden obwohl dies das Geraumlusch verstaumlrken kann
12
3
Eingang
XLR weiblichen
1 2
3
Ausgang
XLR maumlnnlichen
Spitze Schaft
Spitze = Signal
Schaft=SchirmMasse
Pin 3 = zu Pin 1 gebruumlckt
Pin 3 = zu Pin 1 gebruumlckt
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
31
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
32
Digitales Audio (AESEBU)AESEBU (Protokoll AES3) ist ein ausgeglichener und uumlber einen Transformator elektrisch isolierter Eingang Er erlaubt die Benutzung von zwei Kanaumllen an einem einzigen abgeschirmten bipolaren Kabel Das gedrillte Kabel muss 3-polig sein eine Impedanz von 100 Ohm haben und mit einem XLR-Steckverbinder (AES3 Standard) abgeschirmt sein
RdnetJeder Port RDNet an Control 2 und Control 8 kann an max 32 kompatiblen Vorrichtungen die in Kaskade geschaltet sind angeschlossen werden Im nachstehenden Beispiel ist der Port der Kontrolleinheit RDNET CONTROL 2 am Eingang DATA INPUT eines AC 26N angeschlossen dessen paralleler Ausgang DATA LINK zum Eingang des naumlchsten AC26N geht Im Beispiel ist [n] eine Nummer zwischen 3 und 32 (maximale Anzahl der anschlieszligbaren Vorrichtungen an nur einem Netz)
RJ 45
|1|2|3|4|5|6|7|8|
Die Gesamtlaumlnge des Kabels CAT5 eines Unternetzes kann NICHT laumlnger als 900 Meter sein
Der Steckverbinder muss wie folgt angeschlossen sein1 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio +) 2 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio -)3 ndash Verfuumlgbar fuumlr andere Funktionen (zB analoge Masse)4 ndash digitale Masse5 ndash digitale Masse6 ndash Verfuumlgbar fuumlr andere Funktionen (zB Versorgung)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
EINSCHALTEN
Beim Einschalten der Vorrichtung startet die Initialisierung die einige Sekunden lang dauert Auf dem Display wird das Modell das Logo und der Fortschrittsbalken der Ladung des Programms angezeigt
Nach der Initialisierung erscheint auf dem Display das Menuumlfenster Meters Um die Angaben im Detail zu erfahren beziehen Sie sich bitte auf das Kapitel BESCHREIBUNG DES MENUumlFENSTERS Meters
AC26N kann jetzt benutzt werden
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
MENUrsquo PRINCIPALE
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Die sechs Menuumls im Prozessor zeigen undoder konfigurieren die Systemparameter
Anzeige der Levels der Ein- und Ausgaumlnge Anzeige des benutzten Programms und dessen Status Mute schnell
Speicherung Speicherung und Eliminierung der Systemkonfigurationen
Auswahl der Ausgaumlnge je nach Eingangssignal
Konfiguration jedes einzelnen Kanals
Konfiguration der Schnittfrequenzen und der Filtertypen fuumlr jeden einzelnen Ausgang
Zuordnung der Ein- und Ausgaumlnge Kontrast des Displays Firmware-Version Eingaumlnge und andere Optionen
Das Menuuml und die einzelnen Optionen der Anzeige koumlnnen durch Drehen des Drehgriffes FUNKTIONS SELECTOR ( ) ausgewaumlhlt werden
Die Hauptmenuumls sind
Meters
Preset
Matrix
Ch Job
X-Over
Option
Um die Auswahl zu treffen muss der gewuumlnschte Parameter auswaumlhlt und der Drehgriff Push Enter( | ) gedruumlckt werdenDas selbe Verfahren muss fuumlr die Auswahl undoder die Aumlnderung der Optionen innerhalb der Menuumlpunkte angewendet werden
BESCHREIBUNG DES MENUumlFENSTERS Meters
Diese Seite erlaubt die Konfigurationen und den allgemeinen Status der Ein- und Ausgaumlnge der benutzten Programmversion dessen Status und die Steuerung des Systems anzuzeigen
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
KONFIGURATION UND ANZEIGE
Um in das Fenster des Hauptmenuumls zu gelangen muss die Taste Menuuml ( ) auf der Frontseite der Vorrichtung gedruumlckt werdenMit der Taste ESC ( ) kehrt man von jeder Seite des Menuumls auf die vorherige Seite zuruumlck
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
33
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
34
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziertBei den digitalen Eingangssignalen entspricht die Angabe A und B dem EingangDreht man den Drehgriff FUNCTIONS SELECTOR [2] durchlaumluft man zyklisch die Ein- und Ausgangskanaumlle und die Angabe Mute allgemein (d) der ausgewaumlhlte Kanal wird hervorgehoben
b) BALKEN FUumlR DAS KOMPRESIONSLEVELMUTE KANAL
SIGNALKOMPRESSIONDie Signalkompression wird durch das Gleiten des rechten Balkens von oben nach unten angezeigt
MUTE Jeder einzelne Kanal kann auf Mute gestellt werden Den Kanal auswaumlhlen und den Drehgriff Push Enter [2] druumlcken um die Aumlnderung des Status zu bestaumltigen Die Angabe des Kanals wird durch den Buchstaben M ersetzt und der Balken wird komplett hervorgehobenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werden
c) BALKEN DES SIGNALLEVELSDie Anzeige des Levels jedes einzelnen Kanals wird durch das Gleiten des linken Balkens angezeigt
d) MUTE ALLGEMEINEs ist moumlglich alle Ein- und Ausgaumlnge gleichzeitig auf Mute zu schalten Den Drehgriff FUNCTIONS SELECTOR drehen den Buchstaben M waumlhlen und dann den Drehgriff Push Enter druumlckenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werdenDie allgemeine Stummschaltung hat eine houmlhere Prioritaumlt als die Stummschaltung der einzelnen Kanaumlle
e) ANSTEUERUNGSARTENEs wird angezeigt wie AC26N benutzt wird undoder an welchen Vorrichtungen es angeschlossen ist
= Benutzung stand-alone Kein Anschluss an einer externen Vorrichtung
= Direkt am Netz RDnet und am Computer angeschlossen
= Uumlber USB-Kabel direkt am Computer angeschlossen
f) ANZEIGE DES STATUS DER EINSTELLUNGENHier wird angezeigt ob einer oder mehrere Parameter des geladenen Programms im Vergleich zur letzten Speicherung veraumlndert wurden
Original-Programm
Programm mit veraumlnderten Parametern
g) EINGESTELLTES PROGRAMMDie Nummer zeigt das vom System geladene und benutzte Programm in Bezug auf die Lokalisierung der Speicherung an Fuumlr weitere Details beziehen Sie sich bitte auf das Menuuml Preset
Local
NET
USB
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
BESCHREIBUNG DES MENUumlFENSTERS Ch Job
Dieses Fenster erlaubt die Anzeige der Konfiguration jedes einzelnen Kanals
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) SIGNALLEVELZeigt die Signalstaumlrke an Das Ansteigen der Signalintensitaumlt wird in Dezibel (dB) ausgedruumlckt Der Parameter kann zwischen -8000 dB und +2000 dB in Schritten von 001 dB ausgewaumlhlt werden Ein Anstieg von 6 dB ist fast gleich eine Verdoppelung in linearer Skala des Spannungswertes des SignalsBei einer Staumlrke von 0 dB wird das Signal verstaumlrkt waumlhrend es ein einer Staumlrke von weniger als 0 dB abgeschwaumlcht wird
c) VERZOumlGERUNG DES SIGNALS (DELAY)Das wiedergegebene Audio-Signal kann verzoumlgert werden um die akustische Ausrichtung zu erlauben Dies gleicht die verschiedenen Positionen der Lautsprecher bei der Installation und Klangwiedergabe aus und wird in mS ausgedruumlckt Der Parameter kann zwischen 00 mS und 729 mS in Schritten von 01mS ausgewaumlhlt werden
Um ein Audiosignal auszurichten kann folgende Formel benutzt werden
Verzoumlgerung = GAPx1000)344
Verzoumlgerung = mS (in Millisekunden ausgedruumlckt)GAP = Abstand des Lautsprechers vom Referenzpunkt (in Metern ausgedruumlckt)Klanggeschwindigkeit = 344 ms
d) MUTEJeder einzelne Kanal kann auf Mute gestellt werden Derselbe Befehl kann im Fenster des Menuumls Meters aktiviert werden PS Die al lgemeine Stummschaltung hat eine houmlhere Priori taumlt als die Stummschaltung der einzelnen Kanaumlle
e) PHASEErlaubt die Phasenrotation um 180deg zum EingangssignalDiese Rotation erlaubt vor Allem die Optimierung der niederen Frequenzen bei komplexen Installationen
f) ENTZERRUNGENDieser Befehl oumlffnet das Menuumlfenster fuumlr die Entzerrung des einzelnen Kanals Er wird vor Allem benutzt um eine oder mehrere Frequenzen zu korrigieren die gedaumlmpft oder verstaumlrkt werden muumlssen
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
35
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
36
AC26N verwaltet 12 Filter fuumlr jeden einzelnen Ein- und Ausgangskanal mit drei verschiedenen Konfigurationen- Equalizer PEQ (peaking equalizer) ist ideal um nur ein bestimmtes Frequenzband
zu identifizieren zu isolieren und zu korrigieren Es gehen alle Frequenzen durch aber nur die um die mittlere Frequenz steigt und sinkt um eine bestimmte Bandbreite und eine bestimmte Staumlrke
- Equalizer High-Shelf geht alle Frequenzen durch aber die Frequenzen uumlber der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
- Equalizer Low-Shelf geht alle Frequenzen durch aber die Frequenzen unter der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
f Nummerierung der 12 verfuumlgbaren Filter fuumlr diesen Ein- oder Ausgang1
f2 Es wird der Filtertyp angezeigt
Dis Ausgeschaltet (nicht vorhanden)
PEQ Peaking equalizer
Sh H Filter High-Shelf
Sh L Filter Low-shelf
Beispiele PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
ANMERKUNGDer Parameter Bw legt das Frequenzfeld neben der eingestellten Frequenz fest wo der Filter aktiviert wird je houmlher der Bw-Wert desto houmlher das Frequenzfeld (1Bw=1 Oktave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filter High-Shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filter Low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) KOMPRESSIONDieser Befehl oumlffnet das Menuumlfenster fuumlr die Kompression des einzelnen Kanals
g1) TresholdIdentifiziert die Schwelle an der das Kompressionsverhaumlltnis beginnt Der Basiswert 11
g2) RatioIdentifiziert das Kompressionsverhaumlltnis zwischen dem Ein- und Ausgangssignal
g3) Post Gain Attach Release HoldDiese Daten entsprechen dem Kompressionsverhaumlltnis das man erreichen moumlchte
Post Gain ist der Gewinn am AusgangAttack ist die Anschlusszeit Release ist die ReleasezeitHold ist die Beibehaltungszeit
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
BESCHREIBUNG DES MENUumlFENSTERS Preset
Dieses Fenster erlaubt bis zu 32 Konfigurationen im AC26N zu speichernDer Hersteller liefert das System mit einem voreingestellten Programm das auf Position 0 gespeichert ist und nicht uumlberschrieben werden kann
032 Es zeigt die Lokalisierung der Speicherung der KonfigurationDiese Nummer erscheint auch im Fenster Meters auf der Position (g) Das benutzte Programm kann jederzeit vom Benutzer angezeigt werden
Empty Preset Es ist der Name der der Nummer der Lokalisierung zugeordnet wird wenn keine Einstellung gespeichert ist (leer)
Local preset Es i s t de r Name de r de r Nummer de r Loka l i s i e rung zugeordnet wird wenn eine Konfiguration gespeichert wird
ANMERKUNG = Man kann eine Einstellung mit dem gewuumlnschten Namen mit max 16 Buchstaben nur speichern wenn man die Schnittstelle uumlber den Computer benutzt
Bei der Wahl eines Programms erscheint folgendes Fenster
Anzeige des Namens der dem Programm zugeordnet istUm auf die Anwendung einzuwirken stehen 3 Auswahlmoumlglichkeiten zur Verfuumlgung
Das Programm wird im Speicher des AC 26N gespeichert
Das Programm wird geloumlscht
Das Programm wird geladen und ist bereit fuumlr die Benutzung
Save
Del
Load
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
37
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
38
BESCHREIBUNG DES MENUumlFENSTERS X-Over
Dieses Fenster erlaubt fuumlr jeden Ausgang einen Bassdurchgangsfilter einen Hochdurchgangsfilter oder mittels Kombination von beiden einen Banduumlbergangsfilter zu waumlhlenDer Filter ist ein Linkwitz-Riley wo man die Neigung von 12 dBoct 24dBoct oder 48 dBoct und die entsprechende Schnittfrequenz auswaumlhlen kann
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) AUSGANGSKANAumlLE
Die Steckverbinder am Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) FILTER CROSSOVERDen Filter nach Bedarf waumlhlen Man kann folgendes auswaumlhlen
Dis Kein Filter aktiviert
HP Hochdurchgangsfilter nur den Teil des Audiosignals durchlassen der uumlber der Schnittfrequenz liegt
LP Bassdurchgangsfilter nur den Teil des Audiosignals durchlassen der unter der Schnittfrequenz liegt
Filter-Konfiguration Tiefpass Hochpass
Nichts Dis Dis
Hochpass HP Dis
Tiefpass Dis LP
Bandpass HP LP
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
c) DAumlMPFUNGSNEIGUNGDie Daumlmpfungsneigung des Audiosignals auf der Basis der Verringerung auswaumlhlen die man erreichen moumlchte Je houmlher die Daumlmpfungsneigung bei gleicher Schnittfrequenz desto groumlszliger ist die Signalauswahl Man kann folgendes waumlhlen
12 entsprechend 12 dboct
24 entsprechend 24 dboct
48 entsprechend 48 dboct
d) SCHNITTFREQUENZErlaubt die Durchgangsfrequenz der niederen Frequenzen (Bassdurchgangsfilter) oder der hohen Frequenzen (Hochdruchgangsfilter) einzustellenDie Auswahl des Schnitts bezieht sich auf die Wiedergabe die man erreichen moumlchteDie benutzte Maszligeinheit ist Hz
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
BESCHREIBUNG DES MENUumlFENSTERS Matrix
Erlaubt fuumlr jeden Ausgang das Eingangssignal zu waumlhlen das als Quelle benutzt werden soll
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) AUSGANGSKANAumlLEIdentifizierung des einzustellenden Ausgangskanals
b) IDENTIFIZIERUNG DER EINGAumlNGEDen Signaltyp auswaumlhlen der nach eigener Anforderung jedem einzelnen Ausgang zugeordnet werden soll Man kann folgendes waumlhlen
In A Das Signal wird dem Eingang A zugeordnet
In B Das Signal wird dem Eingang B zugeordnet
In A+B Zuordnung der a lgebra ischen Summe der be iden Eingangssignale A und B
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
BESCHREIBUNG DES MENUumlFENSTERS Option
Erlaubt die Anzeige der Systemeinstellungen wie die Zuordnung der Ein- und Ausgaumlnge Daumlmpfung Displaykontrast und Firmware-Version
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B Src
Diese Option erlaubt die Einstellung des Audio-Signaltyps am Eingang
Analoge Audiosignale (Eingaumlnge A und B)
Digitale Audiosignale (Eingang AESEBU)
DigOut Src
An In =Audiosignale an den analogen Eingaumlngen
Dig In =Audiosignale am digitalen Eingang
OUT 1-2 =Audiosignale an den Ausgaumlngen 1 und 2
OUT 3-4 =Audiosignale an den Ausgaumlngen 3 und 4
OUT 5-6 =Audiosignale an den Ausgaumlngen 5 und 6
Input Mode
An In
Dig In
Indip =
Linked =
Diese Option erlaubt die Audioquelle zu waumlhlen die fuumlr den Steckverbinder AESEBU OUT (digitaler Ausgang) bestimmt ist
Erlaubt die Eingaumlnge zu konfigurieren
Sie sind unabhaumlngig und selbststaumlndig sie unterliegen keinen Verpflichtungen untereinander Sie sind verbunden und funktionieren im Stereo-Modus
Die Kompressoren Filter Verzoumlgerungen die Lautstaumlrke sind bei beiden Kanaumllen identisch
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
39
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
40
Atten PadZeigt an wie der Wahlschalter -6 dB auf der Ruumlckseite eingestellt ist [Ref 5] Dieser Wahlschalter muss aktiviert werden wenn das Level an den analogen Eingaumlngen zu hoch ist Der Wahlschalter wird uumlber die Taste aktiviert im Menuuml gibt es nur eine Anzeige
0dB = Wahlschalter nicht aktiviert
-6dB = Wahlschalter aktiviert
Contrast
10 heller 60 dunkler 100
Fw Vers
Die Eingangssignale sind dieselben wie die Eingangsquelle
Die Eingangssignale werden vom internen Prozessor um -6 dB gedaumlmpft
Erlaubt den Kontrast des LCD-Displays einzustellen um den Unterschied der Helligkeit auf den Installationsort auszurichten Ein deutlicheres Display erlaubt auf korrekte und schnelle Weise innerhalb der Menuumls zu surfenDie Hersteller-Einstellung am Ausgang liegt bei 60
Zeigt die Firmware-Version des Prozessors an
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
41
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
42
TECHNISCHE DATEN
Antwort in FrequenzDynamische GammaCMMRCrosstalkDistorsion
ProzessorFrequenz der DatenausarbeitungAnaloge Converter Verzoumlgerung der VerteilungSpeicherung der Konfigurationen
DisplayTastenBedienungen
Analoger Eingang ndeg2 x XLR (3-poliger Female Stecker)Impedanz des Eingangs gt10KOhmMaximales Level +21dBu ohne PAD
+27dBu bei PAD
Impedanz des Ausgangs 50OhmMaximales Level +21dBu Typ symmetrisch
Typ SPDIF-AESEBU (AES3)
Typ Entsprechend dem Standard des Eingang
Typ
Typ
NETZSPANNUNGABMESSUNGEN (BXHXT)GEWICHT
AUDIO-LEISTUNGEN+- 01dB (20 to 30kHz)116dB typgt 60dB (50 to 10kHz)lt -100dB0002 (1kHz +4dBu)
DIGITALE AUDIO-LEISTUNGEN DSP 2856-bit 48KHz24-bit BURR BROWN15ms32 preset
KONTROLLEN LCD GrafikESC - MENU - FUNCTIONS SELECTIONENTER
EIN-AUSGAumlNGE
Analoger Ausgang ndeg6 x XLR (3-poliger Male Stecker)
Digitaler Eingang ndeg1x XLR (3-poliger female Stecker)
Digitaler Ausgang ndeg1x XLR (3-poliger Male Stecker)
Ein-Ausgang Rdnet ndeg2 x XLR RJ45 (kabel CAT 5) USB Typ B
KONTROLLPARAMETER AUDIOStaumlrke -80dB a +20dB step 01dBVerzoumlgerung Eingang 0 a 729mS step 01 mS
Ausgang 0 a 340mS step 01mSPhasenrotation 0deg - 180deg
KOMPRESSIONSchwelle -80dB a +20dB step 01dBVerhaumlltnis 11 a Inf1 step 001Staumlrke am Ausgang 0dB a 40dB step 01dBAnschlusszeit 1mS a 1000mS step 01mSReleasezeit 1mS a 1000mS step 01mSBeibehaltungszeit 1mS a 1000mS step 01mS
EQUALIZER12 Equalizer fuumlr jeden Ein- und Ausgang
PEQ (parametrischer) Hi-shelf Lo-sheftFrequenz 20Hz a 20KHz step 1HzStaumlrke -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (lediglich PEQ)
FILTER CROSSOVERFilter Linkwitz Riley
HP HochdurchgangsfilterLP Bassdurchgangsfilter
Neigung 12dBoct - 24dBoct - 48dBoctSchnittfrequenz 5Hz a 20KHz step 1Hz
Full-range 100-240Vac 50-60Hz430482x43x130mm 19Kg
AnmerkungenSpezifikationen unterliegen Aumlnderungen ohne Vorankuumlndigung
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
INTRODUCTIONAC26N est un processeur audio numeacuterique pour la gestion de leacutequipement audio conccedilu pour des installations fixes et mobiles Il fonctionne selon une technologie de pointe avec des processeurs agrave 2856bits et des convertisseurs ADDA agrave 24-bits hautes performances Les fonctions du processeur sont les niveaux dentreacutee et de sortie le deacutelai (delay) la polariteacute 12 bandes deacutegalisation par canal dentreacutee et de sortie diffeacuterentes seacutelections de croisement (crossover) et un limiteur hautes performances Le controcircle des filtres a une reacutesolution de 1Hz Les entreacutees et les sorties peuvent ecirctre programmeacutees en plusieurs configurations pour satisfaire tous les besoins AC26N peut ecirctre controcircleacute en temps reacuteel et tous les paramegravetres peuvent ecirctre configureacutes depuis le pupitre frontale et par ordinateur avec interface graphique intuitive accessible via le logiciel laquoDVA Networkraquo et une connexion de reacuteseau deacutedieacutee RDnet ou USBLa mise agrave jour du logiciel pour lUniteacute centrale et DSP par ordinateur portable permet de maintenir le dispositif actualiseacute Il est possible denregistrer et de rappeler 32 configurations preacute-eacutequipeacutees de configuration
Contenu de lemballage - AC26N - Mode demploi- CD logiciel- Cacircble dalimentation
Caracteacuteristiques- 2 entreacutees et 6 sorties avec adressage flexible- Entreacutee et sortie steacutereacuteo AESEBU adressables - DSP 2856-bit- Convertisseurs AD BURR BWOWN 24-bit hautes performances- Freacutequence de reacutesolution des filtres 1 Hz - 12 eacutegaliseurs parameacutetriques pour chaque entreacutee et sortie- 2 filtres de croisement par sortie avec pente seacutelectionnable agrave 122448dBoct- DRC agrave configuration multiple hautes performances pour configuration limiteur
compression pour chaque entreacutee et sortie- Niveau reacuteglable en dB polariteacute et deacutelai pour chaque entreacutee et sortie- Mise agrave jour du micrologiciel par lordinateur- Affichage graphique agrave cristaux liquides- 32 preacutereacuteglages enregistrables par lutilisateur- Interface USB pour le controcircle et la configuration par ordinateur- Interface RDnet permettant de controcircler jusquagrave 256 dispositifs agrave distance
PC
PC
RDNETcontrol(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FONCTIONS DE LA FACE AVANT
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
COMMANDES ET FONCTIONS1) AFFICHAGE
Laffichage graphique agrave cristaux liquides permet de visualiser et deacutediter les informations de lAC26N sans utiliser lordinateur Le contraste peut ecirctre configureacute dans le menu principal
2) MANETTE Functions Selector et Push EnterCe controcircle permet de se deacuteplacer de seacutelectionner et de modifier les paramegravetres dans les menus affichables agrave leacutecranRotation de la manette (Functions Selectors)- permet de se deacuteplacer sur les diffeacuterentes pages du menu - permet de modifier les paramegravetres seacutelectionneacutesPression de la manette (Push Enter)- permet de seacutelectionnervalider les paramegravetres
3) Bouton ESC Ce controcircle permet de quitter les menus afficheacutes ou de revenir agrave la visualisation preacuteceacutedente
4) Bouton Menu Ce controcircle permet dacceacuteder directement au menu principal
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
Fra
nccedilais
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
43
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
Fra
nccedilais
44
DVA Network
AC26N est eacutequipeacute dune interface de reacuteseau proprieacutetaire deacutenommeacutee RDNET au moyen de laquelle il est possible de sinterfacer agrave lordinateur agrave travers un peacuteripheacuterique (RDNET control)
Pour cela un protocole de communication a eacuteteacute deacuteveloppeacute avec lequel il est possible de recevoir et denvoyer les donneacutees ce branchement permet de faire le monitorage en temps reacuteel des paramegravetres du diffuseur comme puissance de sortie tempeacuterature de lamplificateur eacutetat du limiteur etc Il est aussi possible de seacutelectionner diffeacuterentes eacutegalisations ou den creacuteer de nouvelles et de reacutegler les niveaux de volume souhaiteacutes au moyen dun plug-in approprieacute
On conseille de teacuteleacutecharger gratuitement le logiciel DVA Network directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
DVA USB Manager
On conseille de teacuteleacutecharger gratuitement le logiciel DVA USB Manager directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
Le micrologiciel du module amplificateur peut ecirctre remis agrave jour par le port USBPour rendre cette mise agrave jour possible et facile un programme speacutecifique a eacuteteacute deacuteveloppeacute
DOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
CONNEXIONS DU PANNEAU ARRIEgraveRE
1586 75 141210 11 13 169 17
14) Connecteur ldquo USBrdquoCe connecteur USB (type B) permet de connecter le processeur agrave un ordinateur pour le controcircle et la mise agrave jour du micrologiciel via un programme deacutedieacute (DVA Network)
15) PRISE DALIMENTATION MAINSPermet la connexion du cacircble dalimentation fourni de seacuterie
16) PORTE-FUSIBLE FUSELogement pour fusible de ligne
17) INTERRUPTEUR GENERAL POWERLinterrupteur permet de mettre en marche ou deacuteteindre le controcircleur audio
COMMANDES ET FONCTIONS
5) SELECTEUR ldquo-6dBrdquoLe seacutelecteur permet de reacuteduire de 6dB les niveaux dentreacutee analogiques XLR [6] tout en compensant les niveaux eacuteleveacutes de sortie des meacutelangeurs ou dautres dispositifs audio Quand la barre du niveau de signal des entreacutees sur laffichage [1] reste au maximum cela indique que le niveau du signal entrant est eacuteleveacute Il est alors conseilleacute dutiliser latteacutenuation -6dBIl est possible de veacuterifier quand le seacutelecteur est activeacute par le menu Option
6) CONNECTEURS DENTREE ldquoArdquo ET ldquoBrdquoEntreacutees eacutequilibreacutees au niveau de la ligneIls sont en mesure daccepter des connecteurs XLR macircles
7) CONNECTEURS DE SORTIE ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo ET ldquo6rdquoSorties eacutequilibreacutees au niveau de la ligne Ils sont en mesure daccepter des connecteurs XLR femelles
Prendre garde agrave brancher convenablement les sorties sur les diffuseurs ou les amplificateurs en fonction des configurations de chaque canal pour eacuteviter des deacutegacircts et des problegravemes de fonctionnement
Section ldquoAESEBUrdquo
8) CONNECTEUR DENTREE INOutre les entreacutees audio analogiques une entreacutee audio numeacuterique SPDIF-AESEBU (AES3) a eacuteteacute preacutevue et peut ecirctre seacutelectionneacutee par le menu de setupLentreacutee requiert une connexion eacutequilibreacutee en utilisant un connecteur XLR avec un cacircble agrave 3 conducteurs de 110ohm torsadeacute
9) CONNECTEUR DE SORTIE OUTCe connecteur permet de relancer le signal audio dans les entreacutees analogiques ou numeacuteriques ou sur les sorties La source doit ecirctre reacutegleacutee par le menu OptionLa connexion sera conforme agrave la mecircme norme que lentreacutee [reacutef8]
Section ldquoRDNETrdquo
10) CONNECTEUR DENTREE DATA INPUTConnecteur RJ45 entreacutee de donneacutees
11) CONNECTEUR DE SORTIE DATA LINKConnecteur RJ45 sortie de donneacutees pour la connexion de seacuterie en cascade
12) VOYANT LUMINEUX ONCe voyant de couleur verte sallume uniquement quand lAC26N a reconnu et est connecteacute agrave luniteacute principale RDNET par lordinateur
13) VOYANT LUMINEUX ACTIVECe voyant de couleur jaune clignote quand une transmission des donneacutees est active entre RDNET et le dispositif
PUSH
P SHU
SHPU
P SHU
PUSH
CONNEXIONS
Audio analogiquesLes connexions eacutequilibreacutees permettent de reacuteduire au minimum le bruit provoqueacute par les cacircbles et dutiliser de longs cacircblesCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLe connecteur XLR doit ecirctre brancheacute avec la broche 1 agrave la masse la broche 2 au chaud (+) et la broche 3 au froid (-) En cas de cacircble blindeacute brancher le blindage agrave la broche 1Les cacircbles de connexion XLR-XLR et XLR-Jack14(63mm) peuvent semployer pour la connexion agrave lAC26N
12
3
Entreacutee
Entreacutee
XLR - femme
XLR - femme
1 2
3
Sortie
Sortie
XLR - Macircle
XLR - Macircle
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2 = Point chaudPhase +VE
Broche 3 =Point froidPhase -VE
Broche 3 =Point froidPhase -VE
Anneau
Manchon
Pointe Point chaudPhase +VE
Anneau = Point froidPhase -VE
ManchonB Masselindeacute
Pointe
Les connexions deacuteseacutequilibreacutees peuvent semployer mecircme si le bruit provoqueacute par les cacircbles augmente Les cacircbles ne peuvent deacutepasser 5m de longCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLes connexions deacuteseacutequilibreacutees peuvent abaisser le niveau du signal entrant de 6dB Pour remeacutedier agrave cet inconveacutenient il faut brancher la broche 3 agrave la masse mecircme si cela augmente le bruit
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
45
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
46
12
3
1 2
3
Pointe Manchon
Pointe = Signal
Broche 3 = Link to Pin 1
Broche 3 = Link to Pin 1
ManchonB Masselindeacute
Audio numeacuteriques (AESEBU)
AESEBU (protocole AES3) est une entreacutee eacutequilibreacutee isoleacutee eacutelectriquement agrave laide dun transformateur Elle permet demployer deux canaux audio dans un seul cacircble bipolaire blindeacute Les caracteacuteristiques du cacircble doivent ecirctre de 3 pocircles impeacutedance 100ohm torsadeacute et blindeacute avec connecteur XLR (AES3 standard)
RJ 45
|1|2|3|4|5|6|7|8|
RDnet
Chaque port RDNet des Control 2 et Control 8 peut ecirctre brancheacute agrave un maximum de 32 dispositifs compatibles placeacutes en cascade Dans lexemple suivant le port de luniteacute de controcircle RDNET CONTROL 2 est relieacute agrave lentreacutee DATA INPUT dun AC26N dont la sortie parallegravele DATA LINK est envoyeacutee agrave lentreacutee de lAC26N successif Dans lexemple [n] est un nombre compris entre 3 et 32 (limite maximale des dispositifs que lon peut relier agrave un sous-reacuteseau)
La longueur totale du cacircble CAT5 dun sous-reacuteseau NE peut PAS deacutepasser 900 megravetres
Le connecteur doit ecirctre relieacute comme 1 ndash disponible pour dautres fonctions (par exemple audio +) 2 ndash disponible pour dautres fonctions (par exemple audio )3 ndash disponible pour dautres fonctions (par exemple masse analogique)4 ndash masse numeacuterique5 ndash masse numeacuterique6 ndash disponible pour dautres fonctions (par exemple alimentation)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
MISE EN MARCHE
Lors de la mise en marche du dispositif linitialisation deacutebute et dure quelques secondes Leacutecran affiche le modegravele le logo et la barre de progression du chargement du programme
En fin de processus dinstallation leacutecran affiche la fenecirctre du menu Meters Pour connaicirctre les indications en deacutetail consulter le paragraphe DESCRIPTION FENETRE MENU Meters
LAC26N est precirct agrave lemploi
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION ET VISUALISATION
Pour entrer dans la fenecirctre du menu principal il faut pousser sur la touche MENU ( ) agrave lavant du dispositifDune page quelconque du menu en poussant sur la touche ESCrdquo ( ) on revient automatiquement sur la page-eacutecran preacuteceacutedente
MENU PRINCIPAL
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Le processeur contient six menus Ils montrent etou configurent les paramegravetres du systegravemeLes menus principaux sont
Meters Visualisation des niveaux des entreacutees et des sorties visualisation du programme utiliseacute et eacutetat mute rapide
Preset Meacutemoriser enregistrer et eacuteliminer les configurations du systegraveme
Matrix seacutelectionner les sorties en fonction du signal entrant
Ch Job configuration de chaque signal
X-Over configurer les freacutequences de coupure et les types de filtres pour chaque sortie
Option attribution des entreacutees et des sorties contraste daffichage la version du micrologiciel les entreacutees et dautres options
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
47
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
48
DESCRIPTION DE LA FENETRE MENU Metersrdquo
Cette fenecirctre permet de visualiser les configurations et leacutetat geacuteneacuteral des entreacutees et des sorties la version du programme utiliseacute son eacutetat et le mode de pilotage du systegraveme
Les menus et les options afficheacutees peuvent se seacutelectionner en tournant la manette ldquoFUNCTIONS SETECTORrdquo ( ) Pour avoir accegraves agrave linteacuterieur de la seacutelection il faut mettre le paramegravetre souhaiteacute en eacutevidence et pousser sur la manette ldquoPush Enterrdquo ( | ) Il faut en faire de mecircme pour seacutelectionner etou modifier les options dans les commandes du menu
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositifAvec des signaux dentreacutee numeacuteriques les indications ldquoArdquo et ldquoBrdquo correspondent agrave lentreacuteeEn tournant la manette ldquoFUNCTIONS SELECTORrdquo [2] on fait deacutefiler en mode cyclique les canaux dentreacutee de sortie et lindication de mute geacuteneacuteral (d) le canal seacutelectionneacute est mis en eacutevidence
b) BARRE DE NIVEAU DE COMPRESSIONMUTE CANAL
COMPRESSION DE SIGNALLa compression du signal est visualiseacutee par le deacutefilement de la barre de droite de haut en bas
MUTE Chaque canal peut ecirctre placeacute en mute Seacutelectionner le canal et pousser sur la manette ldquoPush Enterrdquo [2] pour valider le changement deacutetat Lindication du canal sera remplaceacutee par la lettre M et la barre sera totalement mise en eacutevidencePour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterations
c) BARRE DE NIVEAU DE SIGNALLindication du niveau de chaque canal est signaleacutee par le deacutefilement de la barre de gauche
d) MUTE GENERALIl est possible de mettre simultaneacutement toutes les entreacutees et les sorties en mute Tourner la manette ldquoFUNCTIONS SELECTORrdquo seacutelectionner la lettre M et pousser sur la manette Push EnterPour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterationsLe mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) MODES DE COMMANDEIl affiche le mode dutilisation etou les dispositifs qui sont relieacutes agrave lAC26N
Local = utilisation autonome Aucune connexion agrave un dispositif exteacuterieur
NET = relieacute directement au reacuteseau deacutedieacute RDNet et agrave lordinateur
USB = relieacute directement agrave un ordinateur par cacircble USB
f) INDICATION DETAT DE PARAMETRAGECette indication permet de constater si un ou plusieurs paramegravetre(s) du programme chargeacute aont eacuteteacute modifieacute(s) par rapport au dernier sauvetage
= programme dorigine
= programme avec des paramegravetres modifieacutes
g) PROGRAMME CONFIGURELe chiffre indique le programme chargeacute et utiliseacute par le systegraveme agrave lemplacement de sauvetage Consulter le menu de Preset pour de plus amples deacutetails
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
DESCRIPTION DE LA FENETRE MENU Ch Job
Cette fenecirctre permet dafficher la configuration de chaque canal
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) NIVEAU DU SIGNALIndique le gain du signal Laugmentation de lintensiteacute dun signal est libelleacutee en deacutecibel (dB) Le paramegravetre peut ecirctre seacutelectionneacute de -8000dB agrave +2000dB avec des pas de 001dB Une augmentation de 6dB est eacutegale approximativement au redoublement agrave leacutechelle lineacuteaire du niveau du signal sous tensionAvec un gain supeacuterieur agrave 0dB le signal est amplifieacute tandis quavec un gain infeacuterieur agrave 0dB le signal est atteacutenueacute
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
49
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
50
c) DELAI DU SIGNAL (DELAY)Le signal audio reproduit peut ecirctre retardeacute pour permettre lalignement acoustique Cela compense les diffeacuterentes positions des diffuseurs pendant linstallation et la reproduction sonore Il se libelle en mS Le paramegravetre peut ecirctre seacutelectionneacute de 00mS agrave 729mS avec un pas de 01mSPour aligner un signal audio il est possible dutiliser la formule suivante
Deacutelai = (GAPx1000)344
Deacutelai = ms (en millisecondes)GAP = distance du diffuseur du point de reacutefeacuterence (en megravetres)Vitesse du son = 344ms
d) MUTEChaque canal peut ecirctre placeacute en mute La mecircme commande peut ecirctre activeacutee dans la fenecirctre du menu meters NB Le mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) PhasePermet la rotation de phase de 180deg par rapport au signal entrantCette rotation permet loptimisation surtout des basses freacutequences dans les installations complexes
f) EGALISATIONCette commande ouvre la fenecirctre du menu deacutegalisation de chaque canal Elle sert surtout pour corriger une ou plusieurs freacutequences qui doivent ecirctre atteacutenueacutees ou augmenteacutees
M M
LAC26N gegravere 12 filtres par canal dentreacutee et sortie avec trois types de configurations diffeacuterentes - Leacutegaliseur PEQ (peaking equalizer) est ideacuteal pour identifier isoler et
corriger une seule plage de freacutequences bien deacutetermineacutee Toutes les freacutequences passent mais il augmente ou diminue uniquement celles autour de la freacutequence centrale pour une bande preacutecise et un gain deacutefini
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessus de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessous de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
f Numeacuterotation des 12 filtres disponibles pour cette entreacutee ou cette sortie1
f Le type de filtre est afficheacute 2
Dis Deacutesactiveacute (absent)
PEQ Peaking equlizer
Sh H Filtre high-shelf
Sh L Filtre high-shelf
Exemples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
REMARQUELe paramegravetre Bw deacutetermine le champ de freacutequences adjacent agrave la freacutequence configureacutee ougrave est activeacute le filtre Plus la valeur Bw est eacuteleveacutee plus vaste est le champ de freacutequences (1Bw=1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONCette commande ouvre la fenecirctre du menu de compression de chaque canal
g1) TresholdIdentifie le seuil ougrave commence le rapport de compression La valeur de base 11
g2) RatioIndique le rapport de conversion entre le signal entrant et le signal sortant
g3) Post Gain Attach Release HoldCes donneacutees deacutependent du rapport de conversion que lon veut obtenir - Post Gain est le gain de sortie- Attack est le temps dattaque - Release est le temps de relacircchement- Hold est le temps de maintien
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
52
DESCRIPTION DE LA FENETRE MENU Preset
Cette fenecirctre permet de meacutemoriser jusquagrave 32 configurations dans lAC26NLe fabricant fournit le systegraveme avec un programme configureacute et enregistreacute en position 0 et non susceptible deacutecrasement
032 Elle indique lemplacement de sauvetage de la configurationCe numeacutero apparaicirct dans la fenecirctre Meters en position (g) A tout moment le programme utiliseacute peut ecirctre afficheacute par lutilisateur
Empty Preset Cest le nom qui est associeacute au numeacutero de lemplacement quand aucune configuration (vide) nest enregistreacutee
Local preset Local preset est le nom qui est associeacute au numeacutero de lemplacement quand on enregistre une configuration NB = Il est possible denregistrer une configuration avec lenom souhaiteacute de 16 lettres tout au plus agrave condition que lonutilise linterface via lordinateur
Le nom du programme assigneacute est indiqueacutePour toucher agrave lapplication 3 choix soffrent agrave vous
Save Le programme est enregistreacute en meacutemoire de lAC26N
Del Le programme est effaceacute
Load Le programme est chargeacute et precirct agrave lemploi
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
51
DESCRIPTION DE LA FENETRE MENU X-Over
Cette fenecirctre permet de seacutelectionner un filtre passe bas un filtre passe haut ou par la combinaison des deux de creacuteer un filtre passe bande pour chaque sortieLe filtre actif est un Linkwitz-Riley qui permet de seacutelectionner la pente de 12dBoct 24dBoct ou 48dBoct et sa freacutequence de coupure
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) CANAUX DE SORTIE
Les connecteurs de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) FILTRE CROSSOVERSeacutelectionner le filtre selon les besoins Il est possible de seacutelectionner
Dis Aucun filtre activeacute
HP Filtre passe-haut laisse passer uniquement la partie de signal audio supeacuterieure agrave la freacutequence de coupure
LP Filtre passe-bas laisse passer uniquement la partie de signal audio infeacuterieure agrave la freacutequence de coupure
Configuration du filtre Passe-haut Passe-bas
Rien Dis Dis
Passe-haut HP Dis
Passe-bas Dis LP
Passe-bande HP LP
12dBoct
24dBoct
Hz
dB
Ga
in 48dBoct
12dBoct
24dBoct
Hz
dB
Ga
in
48dBoct
c) PENTE DATTENUATIONSeacutelectionner la pente datteacutenuation du signal audio en fonction de la diminution que lon veut obtenir Plus la pente datteacutenuation est eacuteleveacutee agrave eacutegaliteacute de freacutequence de coupure plus eacuteleveacutee sera la seacutelection du signal Il est possible de seacutelectionner
12 correspond agrave 12dboct
24 correspond agrave 24dboct
48 correspond agrave 48dboct
d) FREQUENCE DE COUPUREElle permet de reacutegler la freacutequence de passage des freacutequences infeacuterieures (filtre passe-bas) ou des freacutequences supeacuterieures (filtre passe-haut) uniquementLe choix de la coupure deacutepend de la reproduction que lon veut obtenirLuniteacute de mesure utiliseacutee est lHz
Hz
Hz
dB
dB
Ga
in
f0
f0
0dB0dB
0dB
-6dB
freacutequence
freacutequence
freacutequence
freacutequence
Ga
in
f0
0dB
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
53
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
54
DESCRIPTION DE LA FENETRE MENU Matrix
Elle permet de seacutelectionner le signal entrant agrave utiliser comme source pour chaque sortie
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) CANAUX DE SORTIEIdentification du canal sortant agrave reacutegler
b) IDENTIFICATIONS DES ENTREESSeacutelectionner le type de signal agrave associer agrave chaque sortie en fonction des besoins Il est possible de seacutelectionner
In A Le signal entrant A est associeacute
In B Le signal entrant B est associeacute
In A+B La somme algeacutebrique des deux signaux entrants A et B est associeacutee
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
DESCRIPTION DE LA FENETRE MENU Option
Permet dafficher les reacuteglages du systegraveme comme lassignation des entreacutees et des sorties latteacutenuation le contraste de laffichage et la version du logiciel
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcCette option permet de reacutegler le type de signal audio entrant
An In =signaux audio analogiques (entreacutees ldquoArdquo et ldquoBrdquo)
Dig In =signaux audio numeacuteriques (entreacutee AESEBU)
DigOut SrcCette option permet de seacutelectionner la source audio qui sera adresseacutee sur le connecteur AESEBU OUT (sortie numeacuterique)
An In = signaux audio des entreacutees analogiques
Dig In =signaux audio sur lentreacutee numeacuterique
OUT 1-2 = signaux audio sur les sorties 1 et 2
OUT 3-4 = signaux audio sur les sorties 3 et 4
OUT 5-6 = signaux audio sur les sorties 5 et 6
Input ModePermet de configurer les entreacutees
Indip = sont indeacutependantes et autonomes Ne sont soumises agrave aucun type de lien
Linked = sont unies et fonctionnent en mode steacutereacuteo Les compresseurs les filtres les deacutelais le volume sont identiques pour les deux canaux
Atten PadIndique le mode de reacuteglage du seacutelecteur ldquo-6dBrdquo placeacute agrave larriegravere [reacutef 5] Il faut activer ce seacutelecteur quand les niveaux dentreacutee analogiques sont trop eacuteleveacutes Le seacutelecteur sactive uniquement par le bouton Dans le menu il sagit dune simple visualisation
0dB = seacutelecteur non activeacute Les signaux dentreacutee sont identiques agrave la source entrante
-6dB = seacutelecteur activeacute Les signaux entrants sont atteacutenueacutes de -6dB par le processeur interne
ContrastIl permet de reacutegler le contraste de laffichage agrave cristaux liquides pour compenser la diffeacuterence de luminositeacute avec le lieu dinstallation Une plus grande clarteacute de laffichage permet de naviguer convenablement et rapidement dans les menusLe reacuteglage agrave la sortie de lusine du fabricant est de 60
10 plus clair 60 plus fonceacute 100
Fw VersIndique la version du logiciel du processeur
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
55
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
56
DONNES TECHINIQUES
PERFORMANCES AUDIOReacuteponse en freacutequence +- 01dB (20 to 30kHz)Plage dynamique 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsion 0002 (1kHz +4dBu)
PERFORMANCES AUDIO NUMERIQUES Processeur DSP 2856-bit Freacutequence de traitement des donneacutees 48KHzConvertisseurs analogiques 24-bit BURR BROWNDeacutelai de propagation 15msMeacutemorisations des configurations 32 preset
CONTROLES Affichage LCD graficoBoutonsCommandes ESC - MENU - FUNCTIONS SELECTION
ENTERENTREESSORTIESEntreacutee analogique ndeg2 x XLR (3 broches femelle)
Impeacutedance dentreacutee gt10KOhmNiveau maximum +21dBu senza PAD
+27dBu con PADSortie analogique ndeg6 x XLR (3 broches macircle )
Impeacutedance de sortie 50OhmNiveau maximum +21dBuType Balanceacute
Entreacutee numeacuterique ndeg1x XLR (3 broches femelle)Type SPDIF-AESEBU (AES3)
Sortie numeacuterique ndeg1x XLR (3 broches macircle )Type conforme agrave la norme de lentreacutee
EntreacuteesSortie Rdnet ndeg2 x XLR RJ45 (cacircble CAT 5)USB Type B
PARAMETRES DE CONTROLE DU SONGain -80dB a +20dB eacutetape 01dBDeacutelai Entreacutee 0 a 729mS eacutetape 01 mS
Sortie 0 a 340mS eacutetape 01mSRotation de phase 0deg - 180deg
COMPRESSIONSeuil -80dB a +20dB eacutetape 01dBRapport 11 a Inf1 eacutetape 001Gain agrave la sortie 0dB a 40dB eacutetape 01dBTemps dattaque 1mS a 1000mS eacutetape 01mSTemps de relacircchement 1mS a 1000mS eacutetape 01mSTemps de maintien 1mS a 1000mS eacutetape 01mS
EGALISEURS12 eacutegaliseurs pour chaque entreacutee et sortieType PEQ (parameacutetrique) Hi-shelf Lo-sheft
Freacutequence 20Hz a 20KHz eacutetape 1HzGain -30dB a +15dB eacutetape 001dBBande 005dB a 2dB eacutetape 001dB (uniquement pour PEQ)
FILTRES CROSSOVERFiltre Linkwitz Riley
Type HF high-shelfLF low-shelf
Pente 12dBoct - 24dBoct - 48dBoctFreacutequence de coupure 5Hz a 20KHz eacutetape 1Hz
ALIMENTATION Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)POIDS 19Kg
Remarques Speacutecifications sujettes agrave modifications sans preacuteavis
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
2 VIE ATTIVO2 WAY ACTIVE
3 VIE PASSIVO3 WAY PASSIVE
L
L
A
A
HIGH L
MID L
LOW HIGHMID RHIGHMID L
LOW L
HIGH R
MID R
LOW R
R
R
B
B
1
1
2
2
3
3
456
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
Menu Matrix configurationMatrix
57 58
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
EROUIG ATRIX TNM
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
OU
TP
UT
1
OU
TP
UT
2
OU
TP
UT
3
OU
TP
UT
4
OU
TP
UT
5
OU
TP
UT
6
AE
S-E
BU
OU
TP
UT
INP
UT
A
AE
S-E
BU
INP
UT
INP
UT
B
D D D D D D
D D
A A A A A A
A SA
MP
LE
RA
TE
CO
NV
A
LIN
KA
BL
E
SC
HE
MA
A B
LO
CC
HI -
BL
OC
K D
IAG
RA
MB
LO
CK
SC
HA
LT
BIL
D -
SC
HE
MA
S F
ON
CT
ION
NE
LS
LINE ARRAY SUB MONO ATTIVO
LINE ARRAY SUB MONO ACTIVEINGRESSI - INPUT
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
L
L
L
A
A
A
AESEBU IN
AESEBU IN
AESEBU IN
AESEBU OUT
AESEBU IN
AESEBU IN
AESEBU OUT
R
R
R
LR
B
B
B
123456
HIGHMID L
HIGHMID L HIGHMID R
HIGHMID R
LOW L LOW R
LAYER
DISPLAY MEMORY
FADER MODE
LAYER
DISPLAY MEMORY
FADER MODE
Ingresso ANALOGICO
ANALOG Input
Collegamento in cascata
Link connections
Ingresso DIGITALE
DIGITAL inputA B
BALANCED AUDIO INPUTS
-6dB
PUSH PUSH
IN OUT
AES EBUPUSH
Oppure
or
Oppure
or
Menu Option configurationOption
Menu Option configurationOption Menu Option configurationOption
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type Analog
AES out An In
Input type Analog
AES out An In
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
59 60
InA-B Src Dig InInA-B Src Dig InInA-B Src An InInA-B Src An In
frequenzaHz
dB
Gu
ad
ag
no
60 200 2800
0dB0dB
-6dB
Esempio di un sistema a 3-vie
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
Out 1 Out 2 Out 3
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Esempio di un sistema a 3-vie
61 62
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
26NAC 26NAC
R TE
DO
R
MO LEU O R CE S
E O TR L A
S O
O C ND I P
P hsuernE t
o su cti nF nel rS e tc o
E CSME UN
IGCHTE OL SN EOBd
ocaL l
M
0
484
467
430
44
31
75
12
7
DIMENSIONI DIMENSIONSABMESSUNGEN DIMENSIONS
The AC26N manages 12 filters for each individual channel input and output with three different kinds of configuration
- PEQ Equaliser (peaking equalizer) ideal to identify isolate and correct only a certain range of frequencies All frequencies pass only those around the centre frequency are increased and decreased for a given bandwidth and set gain
- High-shelf Equalizer All frequencies pass but frequencies above the selected cut-off frequency are increased or attenuated by the given gain
- Low-shelf Equalizer All frequencies pass but frequencies below the selected cut-off frequency are increased or attenuated by the given gain
f Numbering of the 12 available filters for the specific input or output1
f Displays the kind of filter2
Dis Switched off (not present)
PEQ Peaking equlizer
Sh H High-shelf Filter
Sh L Low-shelf Filter
Examples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
NOTE
The parameter Bw defines the range of frequencies close to the set frequency where the filter is activated the greater the value of Bw the wider is the frequencies range (1 Bw = 1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONThis control opens the menu controlling the compression for the single channel
g1) ThresholdIdentifies the starting threshold for the compression ratio Base value 11
g2) RatioIndicates the conversion ratio between input and output signal
g3) Post Gain Attach Release HoldThese data are in function of the conversion ratio to achieve Post Gain is the output gain Attack is the attack time Release is the release time Hold is the holding time
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
24
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
23
MENU DESCRIPTION - PRESET
This window allows to store up to 32 configurations in the AC26NThe manufacturer provides the system with a program set and saved in position 0 that is not possible to overwrite
032 Indicates the location where the configuration is savedThis number also appears in the window Meters in position (g) The program in use can be displayed at any time by the user
Empty Preset It is the name associated with the location number when no setting is saved (empty)
Local preset It is the name associated with the location number when a setting is saved NOTE = It is possible to save a setting with the desired name up to 16 letters only via the computer interface
When a program is selected the following window is displayed
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
The name of the assigned program is displayed3 possible choices are available when working on the application
Save The program is saved in the AC 26N memory
Del The program is deleted
Load The program is loaded and ready to be used
MENU DESCRIPTION - X-OVER
This window allows to select for each output a low pass filter a high pass filter or create a band-pass filter via the combination of bothThe available filter is a Linkwitz-Riley where it is possible to select slopes of 12 dBoct 24 dBoct or 48 dBoct and their cut-off frequency
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) OUTPUT CHANNELS
The output connectors are identified by the same information provided on the screen printing located on the device rear side
b) CROSSOVER FILTERSelect the filter according to needs It is possible to select
Dis No filter enabled
HP High-pass filter set it to allow only the part of audio signal above the cut-off frequency
LP Low-pass filter set to allow only the part of audio signal below the cut-off frequency
Filter configuration Low-pass High-pass
Nothing Dis Dis
High-pass HP Dis
Low-pass Dis LP
Band-pass HP LP
12dBoct
24dBoct
Hz
dB
48dBoct
12dBoct
24dBoct
frequency
frequency
frequency
frequency
Hz
dB
48dBoct
c) ATTENUATION SLOPESelect the attenuation slope of the audio signal on the basis of the desired attenuation The higher the attenuation slope at the same cut-off frequency the greater the signal selection It is possible to select
12 equal to 12 dBoct
24 equal to 24 dBoct
48 equal to 48 dBoct
d) CUT-OFF FREQUENCYTo set the passing frequency for the lower frequencies only (low-pass filter) or the higher frequencies only (high-pass filter)The choice of the cut-off depends on the desired sound reproductionThe unit of measurement used is Hz
Hz
Hz
dB
dB
Ga
inG
ain
Ga
inG
ain
f0
f0
0dB0dB
0dB
-6dB
-6dB
0dB
0dB
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
26
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
25
MENU DESCRIPTION - MATRIX
For each output it allows to select the input signal to use as the source
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) OUTPUT CHANNELSIdentification of the output channel to set
b) IDENTIFICATIONS OF THE INPUTSIt selects the type of signal to match each output as needed It is possible to select
In A Associated with the input signal ldquoArdquo
In B Associated with the input signal ldquoBrdquo
In A+B Associated with the algebraic sum of the two input signals ldquoArdquo and ldquoBrdquo
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
MENU DESCRIPTION - OPTION
Allows to display the system settings such as the allocation of the inputs and outputs attenuation display contrast and firmware version
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcThis option allows to set the type of input audio signal
An In = Analog audio signals (inputs A and B)
DigIn = Digital audio signals (AESEBU input)
DigOut SrcThis option allows to select the audio source that will be forwarded to the connector AESEBU OUT (digital output)
An In = Audio signals available at analog inputs
Dig In = Audio signals available at digital inputs
OUT 1-2 = Audio signals available on outputs 1 and 2
OUT 3-4 = Audio signals available on outputs 3 and 4
OUT 5-6 = Audio signals available on outputs 5 and 6
Input ModeIt allows to configure the inputs
Indip = They are independent not subject to constraints of any kind between them
Linked = They are connected and work in stereo mode Compressors filters delays volume are identical for the two channels
Atten PadIt shows how to set the -6 dB switch located on the rear side [Ref 5] It is necessary to activate this selector when the analog input levels are too high The selector can be activated only by means of the button the menu is for display only
0 dB = Selector not activated The input signals are the same as the input source
-6 dB = Selector activated The input signals are attenuated by -6 dB with reference to the inner
processor
ContrastAllows to adjust the LCD display contrast to compensate for the brightness difference at the installation sites Greater display brightness allows to navigate correctly and quickly within the menuThe manufacturer output setting is 60
10 More bright 60 More dark 100
Fw VersIt shows the processor firmware version
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
28
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
27
TECHINICAL SPECIFICATION
AUDIO PERFORMANCEFrequency Response +- 01dB (20 to 30kHz)Dynamic Range 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistortion 0002 (1kHz +4dBu)
DIGITAL AUDIO PERFORMANCE Processor DSP 2856-bit Data processing Frequency 24-bit BURR BROWNAnalog converters 24-bit BURR BROWNPropagation Delay 15msStoring configurations 32 preset
CONTROLS Display LCD graficoButtonsControls ESC - MENU - FUNCTIONS SELECTION
ENTERINPUTSOUTPUTSAnalog Input ndeg2 x XLR (3 pole female)
Input impedance gt10KOhmMaximum Level +21dBu senza PAD
+27dBu con PADAnalog Output ndeg6 x XLR (3 pole male)
Output impedance 50OhmMaximum Level +21dBu Type Balanced
Digital Input ndeg1x XLR (3 pole female)Type SPDIF-AESEBU (AES3)
Digital Output ndeg1x XLR (3 pole male)Type Compliant with the input standard
RDnet InputsOutput ndeg2 x XLR RJ45 (CAT 5 cable)USB Tipo B
SOUND CONTROL PARAMETERSGain -80dB a +20dB step 01dBDelay
Input 0 a 729mS step 01 mSOutput 0 a 340mS step 01mSPhase Rotation 0deg - 180deg
COMPRESSIONThreshold -80dB a +20dB step 01dBRatio 11 a Inf1 step 001Output gain 0dB a 40dB step 01dBAttack time 1mS a 1000mS step 01mSRelease time 1mS a 1000mS step 01mSHold time 1mS a 1000mS step 01mS
EQUALIZERS12 equalizers for each input and outputType PEQ (parametrico) Hi-shelf Lo-sheft
Frequency 20Hz a 20KHz step 1HzGain -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (only with PEQ)
CROSSOVER FILTERSFilter Linkwitz Riley
Type HP High-pass LP Low-pass
Slope 12dBoct - 24dBoct - 48dBoctCUT-OFF FREQUENCY 5Hz a 20KHz passo 1Hz
POWER SUPPLY Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)
1719x17x51 inch (WxHxD)WEIGHT 19Kg
(42 lbs)Note Specifications subject to change without notice
EMI CLASSIFICATIONAccording to the standards EN 55103 this equipment is designed and suitable to operate in E3 (or lower E2 E1) Electromagnetic environments
EINLEITUNG
Verpackungsinhalt
Eigenschaften
AC26N ist ein digitaler Audio-Prozessor fuumlr die Verwaltung von Audio-Systemen der fuumlr feste und mobile Installationen entwickelt wurde AC26N benutzt die modernste Technologie mit 2856 bit-Prozessoren und 24-bit-ADDA-Wandlern mit hoher Leistungsfaumlhigkeit Die verfuumlgbaren Funktionen des Prozessors sind Ein- und Ausgangsstufen Verzoumlgerung (delay) Polaritaumlt 12 Equalizer-Frequenzen fuumlr Ein- und Ausgangskanal viele Crossover-Wahlmoumlglichkeiten und Limiter mit hoher Leistung Die Filter-Kontrolle hat eine Aufloumlsung von 1 Hz Die Ein- und Ausgaumlnge koumlnnen mit unterschiedlichen Einstellungen geregelt werden um allen Anforderungen gerecht zu werden AC26N kann in Echtzeit kontrolliert werden und jeder Parameter kann am Frontpaneel und vom Computer mit intuitiver graphischer Schnittstelle mittels Software DVA Network zugaumlnglich und einer Netzverbindung RDnet oder uumlber USB eingestellt werdenDie SW-Aktualisierung fuumlr CPU und DSP uumlber PC erlaubt die Vorrichtung auf dem aktuellen Stand zu halten Man kann 32 vorgesehene Konfigurationen speichern und aufrufen
- AC26N - Bedienungsanleitung- Software-CD- Versorgungskabel
- 2 Ein- und 6 Ausgaumlnge mit flexibler Adressierung- Adressierbarer Stereo-Ein- und Ausgang AESEBU - DSP 2856-bit- AD-Wandler BURR BROWN 24-bit mit hoher Leistungsfaumlhigkeit- Aufloumlsungsfrequenz der Filter 1 Hz - 12 parametrische Equalizer fuumlr jeden Ein- und Ausgang- 2 Crossover-Filter fuumlr jeden Ausgang mit auswaumlhlbarer Neigung 122448dBoct- DRC Multikonfiguration mit hoher Leistungsfaumlhigkeit fuumlr die Konfiguration des
Limitersder Kompression jedes Ein- und Ausgangs- Einstellbare dB-Stufe Polaritaumlt und Verzoumlgerung (delay) fuumlr jeden Ein- und Ausgang- Firmware-Aktualisierung uumlber PC- Graphisches LCD-Display- 32 Voreinstellungen vom Benutzer einstellbar- USB-Schnittstelle fuumlr die Kontrolle und Konfiguration mit dem Computer- Schnittstelle RDnet welche erlaubt bis zu 256 fern liegende Vorrichtungen
zu kontrollieren
PC
PC
RDNET control(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FUNKTIONEN VORDERSEITE
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
BEDIENUNGEN UND FUNKTIONEN
1) DISPLAYDas graphische LCD-Display erlaubt die Informationen des AC26N ohne einen Computer zu benutzen anzuzeigen und zu editieren Der Kontrast kann im Hauptmenuuml eingestellt werden
2) DREHGRIFF Functions Selector UND Push EnterDiese Kontrolle erlaubt sich in den Menuumls auf dem Display zu bewegen und die Parameter auszuwaumlhlen und zu veraumlndernDrehung des Drehgriffes (Functions Selectors)- Man kann sich innerhalb der verschiedenen Menuumlseiten bewegen- Erlaubt die Veraumlnderung der ausgewaumlhlten ParameterDruck des Drehgriffes (Push Enter)- Erlaubt die AuswahlBestaumltigung der Parameter
3) Taste ldquoESCrdquo Diese Kontrolle erlaubt die angezeigten Menuumls zu verlassen oder zur vorherigen Anzeige zuruumlckzukehren
4) Taste ldquoMenuumlrdquo Diese Kontrolle erlaubt den direkten Zugang zum Hauptmenuuml
Deuts
chD
euts
chB
ed
ien
un
gsan
leit
un
gB
ed
ien
un
gsan
leit
un
g
29
Deuts
chD
euts
chB
ed
ien
un
gsan
leit
un
gB
ed
ien
un
gsan
leit
un
g
30
DVA USB Manager
Die Firmware des Verstaumlrkermoduls kann uumlber den USB-Anschluss aktualisiert werdenUm diesen Vorgang zu ermoumlglichen und zu vereinfachen wurde ein dediziertes Programm entwickelt das beim Hersteller angefordert und auf einen Computer installiert werden muss
Wir empfehlen die Software DVA USB Manager direkt von der Webseite dB Technologies (wwwdbtechnologiescom) im Abschnitt laquoSoftware amp Controllerraquo herunterzuladen
DVA Network
AC26N ist mit einer eigenen als RDNET bezeichneten Netzschnittstelle ausgestattet dank der es uumlber ein Interface (RDNET Control) an einen Computer angeschlossen werden koumlnnenHierzu wurde ein Kommunikationsprotokoll entwickelt mit dem die Daten empfangen und gesendet werden Dank dieser Verbindung koumlnnen die Lautsprecherparameter wie Ausgangsleistung Verstaumlrkertemperatur Limiterstatus usw in Echtzeit kontrolliert werden Auszligerdem koumlnnen verschiedene Entzerrungen ausgewaumlhlt bzw neue erstellt werden oder die gewuumlnschte Lautstaumlrke eingestellt werden
Wir empfehlen die Software DVA_Network direkt von der Webseite dB Technologies (wwwdbtechnologiescom) im Abschnitt laquoSoftware amp Controllerraquo herunterzuladenDOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
RUumlCKWANDANSCHLUumlSSE
1586 75 141210 11 13 169 17
14) USB-SteckverbinderDieser USB-Steckverbinder (Typ B) erlaubt den Prozessor an einem Computer anzuschlieszligen um die Firmware mit dem speziellen Programm (DVA Network) zu kontrollieren und zu aktualisieren
15) STROMANSCHLUSS MAINSErlaubt den Anschluss des mitgelieferten Versorgungskabels
16) SICHERUNGSTRAumlGER FUSEAufnahme fuumlr die Netz-Sicherung
17) HAUPTSCHALTER POWERDer Schalter erlaubt das Aus- und Einschalten des Audio-Controllers
BEDIENUNGEN UND FUNKTIONEN
5) WAHLSCHALTER -6dBDer Wahlschalter erlaubt das Level des analogen Eingangs XLR [6] um 6 dB zu verringern und gleichzeitig das hohe Ausgangslevel der Mixer oder anderer Audio-Vorrichtungen auszugleichen Wenn der Balken des Signallevels der Eingaumlnge auf dem Display [1] immer auf Maximum steht zeigt dies an dass das Signallevel am Eingang hoch ist und es wird empfohlen die Daumlmpfung -6dB zu benutzenIm Menuuml Option ist es moumlglich zu kontrollieren ob der Wahlschalter aktiviert ist
6) STECKVERBINDER AM EINGANG A UND BAuf Leitungslinie ausgeglichene EingaumlngeSie koumlnnen auch XLR-Steckdosen aufnehmen
7) AUSGANG-STECKVERBINDER ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo UND ldquo6rdquoAuf Leitungslinie ausgeglichene Ausgaumlnge Sie koumlnnen auch XLR-Stecker aufnehmen
Darauf achten dass die Ausgaumlnge korrekt entsprechend der Einstellungen der einzelnen Kanaumlle an den Lautsprechern oder Verstaumlrkern angeschlossen sind um Schaumlden und Fehlfunktionen vorzubeugen
Abschnitt ldquoAESEBUrdquo
8) EINGANGS-STECKVERBINDER INZusaumltzlich zu den analogen Audio-Eingaumlngen wurde ein digitaler Audio-Eingang SPDIF-AESEBU (AES3) vorgesehen der uumlber das Setup-Menuuml ausgewaumlhlt werden kannDer Eingang erfordert einen ausgeglichenen Anschluss mit einem XLR-Steckverbinder mit einem verdrillten Kabel mit 3 Leitern von 110 Ohm
9) AUSGANGS-STECKVERBINDER OUTDieser Steckverbinder erlaubt das Audiosignal an den analogen oder digitalen Eingaumlngen oder Ausgaumlngen zu verteilen Die Quelle muss uumlber das Menuuml Option eingestellt werdenDer Anschluss muss demselben Standard des Eingang entsprechen [Ref 8]
Abschnitt ldquoRDNETrdquo
10) EINGANGS-STECKVERBINDER DATA INPUTSteckverbinder RJ45 fuumlr den Dateneingang
11) AUSGANGS-STECKVERBINDER DATA LINKSteckverbinder RJ45 fuumlr den Datenausgang Fuumlr die serielle Kaskaden-Verbindung
12) LEUCHTANZEIGE ONDiese gruumlne Anzeige leuchtet nur wenn AC26N uumlber den Computer mit der Haupteinheit RDNET verbunden ist und diese erkannt hat
13) LEUCHTANZEIGE ACTIVEDiese gelbe Anzeige blinkt wenn eine Datenuumlbertragung zwischen RDNET und der Vorrichtung aktiv ist
PUSH
P SHU
SHPU
P SHU
PUSH
ANSCHLUumlSSE
Analoge Audio-AnschluumlsseDie ausgeglichenen Anschluumlsse erlauben die Geraumlusche der Kabel auf ein Minimum zu verringern und so die Benutzung langer Kabel zuzulassenDiese Anschluumlsse koumlnnen sowohl an den Ein- als auch an den Ausgaumlngen benutzt werdenDer XLR-Steckverbinder muss mit Pin 1 an Masse Pin 2 am Pluspol (+) und Pin 3 am Minuspol (-) angeschlossen werden Bei einem abgeschirmten Kabel muss die Abschirmung an Pin 1 liegenDie Verbindungskabel XLR-XLR und XLR-Jack 14 (63 mm) koumlnnen fuumlr den Anschluss
12
3
Eingang
XLR weiblichen
Pin 3 = MinuspolErkaumlltungphase -VE
Pin 3 = MinuspolErkaumlltungphase -VE
1 2
3
Ausgang
XLR maumlnnlichen
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Ring
Schaft
Spitze = PluspolWaumlrmephase +VE
Ring = MinuspolErkaumlltungphase -VE
Schaft=SchirmMasse
Spitze
Die nicht ausgeglichenen Anschluumlsse koumlnnen auch benutzt werden wenn die Kabelgeraumlusche ansteigen und diese Kabel duumlrfen nicht laumlnger sein als 5 MeterDiese Anschluumlsse koumlnnen sowohl an den Ein- als auch an den Ausgaumlngen benutzt werdenDie nicht ausgeglichenen Anschluumlsse koumlnnen das Signallevel am Eingang um 6 dB verringern um dem vorzubeugen muss Pin 3 an Masse angeschlossen werden obwohl dies das Geraumlusch verstaumlrken kann
12
3
Eingang
XLR weiblichen
1 2
3
Ausgang
XLR maumlnnlichen
Spitze Schaft
Spitze = Signal
Schaft=SchirmMasse
Pin 3 = zu Pin 1 gebruumlckt
Pin 3 = zu Pin 1 gebruumlckt
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
31
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
32
Digitales Audio (AESEBU)AESEBU (Protokoll AES3) ist ein ausgeglichener und uumlber einen Transformator elektrisch isolierter Eingang Er erlaubt die Benutzung von zwei Kanaumllen an einem einzigen abgeschirmten bipolaren Kabel Das gedrillte Kabel muss 3-polig sein eine Impedanz von 100 Ohm haben und mit einem XLR-Steckverbinder (AES3 Standard) abgeschirmt sein
RdnetJeder Port RDNet an Control 2 und Control 8 kann an max 32 kompatiblen Vorrichtungen die in Kaskade geschaltet sind angeschlossen werden Im nachstehenden Beispiel ist der Port der Kontrolleinheit RDNET CONTROL 2 am Eingang DATA INPUT eines AC 26N angeschlossen dessen paralleler Ausgang DATA LINK zum Eingang des naumlchsten AC26N geht Im Beispiel ist [n] eine Nummer zwischen 3 und 32 (maximale Anzahl der anschlieszligbaren Vorrichtungen an nur einem Netz)
RJ 45
|1|2|3|4|5|6|7|8|
Die Gesamtlaumlnge des Kabels CAT5 eines Unternetzes kann NICHT laumlnger als 900 Meter sein
Der Steckverbinder muss wie folgt angeschlossen sein1 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio +) 2 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio -)3 ndash Verfuumlgbar fuumlr andere Funktionen (zB analoge Masse)4 ndash digitale Masse5 ndash digitale Masse6 ndash Verfuumlgbar fuumlr andere Funktionen (zB Versorgung)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
EINSCHALTEN
Beim Einschalten der Vorrichtung startet die Initialisierung die einige Sekunden lang dauert Auf dem Display wird das Modell das Logo und der Fortschrittsbalken der Ladung des Programms angezeigt
Nach der Initialisierung erscheint auf dem Display das Menuumlfenster Meters Um die Angaben im Detail zu erfahren beziehen Sie sich bitte auf das Kapitel BESCHREIBUNG DES MENUumlFENSTERS Meters
AC26N kann jetzt benutzt werden
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
MENUrsquo PRINCIPALE
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Die sechs Menuumls im Prozessor zeigen undoder konfigurieren die Systemparameter
Anzeige der Levels der Ein- und Ausgaumlnge Anzeige des benutzten Programms und dessen Status Mute schnell
Speicherung Speicherung und Eliminierung der Systemkonfigurationen
Auswahl der Ausgaumlnge je nach Eingangssignal
Konfiguration jedes einzelnen Kanals
Konfiguration der Schnittfrequenzen und der Filtertypen fuumlr jeden einzelnen Ausgang
Zuordnung der Ein- und Ausgaumlnge Kontrast des Displays Firmware-Version Eingaumlnge und andere Optionen
Das Menuuml und die einzelnen Optionen der Anzeige koumlnnen durch Drehen des Drehgriffes FUNKTIONS SELECTOR ( ) ausgewaumlhlt werden
Die Hauptmenuumls sind
Meters
Preset
Matrix
Ch Job
X-Over
Option
Um die Auswahl zu treffen muss der gewuumlnschte Parameter auswaumlhlt und der Drehgriff Push Enter( | ) gedruumlckt werdenDas selbe Verfahren muss fuumlr die Auswahl undoder die Aumlnderung der Optionen innerhalb der Menuumlpunkte angewendet werden
BESCHREIBUNG DES MENUumlFENSTERS Meters
Diese Seite erlaubt die Konfigurationen und den allgemeinen Status der Ein- und Ausgaumlnge der benutzten Programmversion dessen Status und die Steuerung des Systems anzuzeigen
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
KONFIGURATION UND ANZEIGE
Um in das Fenster des Hauptmenuumls zu gelangen muss die Taste Menuuml ( ) auf der Frontseite der Vorrichtung gedruumlckt werdenMit der Taste ESC ( ) kehrt man von jeder Seite des Menuumls auf die vorherige Seite zuruumlck
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
33
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
34
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziertBei den digitalen Eingangssignalen entspricht die Angabe A und B dem EingangDreht man den Drehgriff FUNCTIONS SELECTOR [2] durchlaumluft man zyklisch die Ein- und Ausgangskanaumlle und die Angabe Mute allgemein (d) der ausgewaumlhlte Kanal wird hervorgehoben
b) BALKEN FUumlR DAS KOMPRESIONSLEVELMUTE KANAL
SIGNALKOMPRESSIONDie Signalkompression wird durch das Gleiten des rechten Balkens von oben nach unten angezeigt
MUTE Jeder einzelne Kanal kann auf Mute gestellt werden Den Kanal auswaumlhlen und den Drehgriff Push Enter [2] druumlcken um die Aumlnderung des Status zu bestaumltigen Die Angabe des Kanals wird durch den Buchstaben M ersetzt und der Balken wird komplett hervorgehobenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werden
c) BALKEN DES SIGNALLEVELSDie Anzeige des Levels jedes einzelnen Kanals wird durch das Gleiten des linken Balkens angezeigt
d) MUTE ALLGEMEINEs ist moumlglich alle Ein- und Ausgaumlnge gleichzeitig auf Mute zu schalten Den Drehgriff FUNCTIONS SELECTOR drehen den Buchstaben M waumlhlen und dann den Drehgriff Push Enter druumlckenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werdenDie allgemeine Stummschaltung hat eine houmlhere Prioritaumlt als die Stummschaltung der einzelnen Kanaumlle
e) ANSTEUERUNGSARTENEs wird angezeigt wie AC26N benutzt wird undoder an welchen Vorrichtungen es angeschlossen ist
= Benutzung stand-alone Kein Anschluss an einer externen Vorrichtung
= Direkt am Netz RDnet und am Computer angeschlossen
= Uumlber USB-Kabel direkt am Computer angeschlossen
f) ANZEIGE DES STATUS DER EINSTELLUNGENHier wird angezeigt ob einer oder mehrere Parameter des geladenen Programms im Vergleich zur letzten Speicherung veraumlndert wurden
Original-Programm
Programm mit veraumlnderten Parametern
g) EINGESTELLTES PROGRAMMDie Nummer zeigt das vom System geladene und benutzte Programm in Bezug auf die Lokalisierung der Speicherung an Fuumlr weitere Details beziehen Sie sich bitte auf das Menuuml Preset
Local
NET
USB
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
BESCHREIBUNG DES MENUumlFENSTERS Ch Job
Dieses Fenster erlaubt die Anzeige der Konfiguration jedes einzelnen Kanals
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) SIGNALLEVELZeigt die Signalstaumlrke an Das Ansteigen der Signalintensitaumlt wird in Dezibel (dB) ausgedruumlckt Der Parameter kann zwischen -8000 dB und +2000 dB in Schritten von 001 dB ausgewaumlhlt werden Ein Anstieg von 6 dB ist fast gleich eine Verdoppelung in linearer Skala des Spannungswertes des SignalsBei einer Staumlrke von 0 dB wird das Signal verstaumlrkt waumlhrend es ein einer Staumlrke von weniger als 0 dB abgeschwaumlcht wird
c) VERZOumlGERUNG DES SIGNALS (DELAY)Das wiedergegebene Audio-Signal kann verzoumlgert werden um die akustische Ausrichtung zu erlauben Dies gleicht die verschiedenen Positionen der Lautsprecher bei der Installation und Klangwiedergabe aus und wird in mS ausgedruumlckt Der Parameter kann zwischen 00 mS und 729 mS in Schritten von 01mS ausgewaumlhlt werden
Um ein Audiosignal auszurichten kann folgende Formel benutzt werden
Verzoumlgerung = GAPx1000)344
Verzoumlgerung = mS (in Millisekunden ausgedruumlckt)GAP = Abstand des Lautsprechers vom Referenzpunkt (in Metern ausgedruumlckt)Klanggeschwindigkeit = 344 ms
d) MUTEJeder einzelne Kanal kann auf Mute gestellt werden Derselbe Befehl kann im Fenster des Menuumls Meters aktiviert werden PS Die al lgemeine Stummschaltung hat eine houmlhere Priori taumlt als die Stummschaltung der einzelnen Kanaumlle
e) PHASEErlaubt die Phasenrotation um 180deg zum EingangssignalDiese Rotation erlaubt vor Allem die Optimierung der niederen Frequenzen bei komplexen Installationen
f) ENTZERRUNGENDieser Befehl oumlffnet das Menuumlfenster fuumlr die Entzerrung des einzelnen Kanals Er wird vor Allem benutzt um eine oder mehrere Frequenzen zu korrigieren die gedaumlmpft oder verstaumlrkt werden muumlssen
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
35
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
36
AC26N verwaltet 12 Filter fuumlr jeden einzelnen Ein- und Ausgangskanal mit drei verschiedenen Konfigurationen- Equalizer PEQ (peaking equalizer) ist ideal um nur ein bestimmtes Frequenzband
zu identifizieren zu isolieren und zu korrigieren Es gehen alle Frequenzen durch aber nur die um die mittlere Frequenz steigt und sinkt um eine bestimmte Bandbreite und eine bestimmte Staumlrke
- Equalizer High-Shelf geht alle Frequenzen durch aber die Frequenzen uumlber der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
- Equalizer Low-Shelf geht alle Frequenzen durch aber die Frequenzen unter der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
f Nummerierung der 12 verfuumlgbaren Filter fuumlr diesen Ein- oder Ausgang1
f2 Es wird der Filtertyp angezeigt
Dis Ausgeschaltet (nicht vorhanden)
PEQ Peaking equalizer
Sh H Filter High-Shelf
Sh L Filter Low-shelf
Beispiele PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
ANMERKUNGDer Parameter Bw legt das Frequenzfeld neben der eingestellten Frequenz fest wo der Filter aktiviert wird je houmlher der Bw-Wert desto houmlher das Frequenzfeld (1Bw=1 Oktave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filter High-Shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filter Low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) KOMPRESSIONDieser Befehl oumlffnet das Menuumlfenster fuumlr die Kompression des einzelnen Kanals
g1) TresholdIdentifiziert die Schwelle an der das Kompressionsverhaumlltnis beginnt Der Basiswert 11
g2) RatioIdentifiziert das Kompressionsverhaumlltnis zwischen dem Ein- und Ausgangssignal
g3) Post Gain Attach Release HoldDiese Daten entsprechen dem Kompressionsverhaumlltnis das man erreichen moumlchte
Post Gain ist der Gewinn am AusgangAttack ist die Anschlusszeit Release ist die ReleasezeitHold ist die Beibehaltungszeit
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
BESCHREIBUNG DES MENUumlFENSTERS Preset
Dieses Fenster erlaubt bis zu 32 Konfigurationen im AC26N zu speichernDer Hersteller liefert das System mit einem voreingestellten Programm das auf Position 0 gespeichert ist und nicht uumlberschrieben werden kann
032 Es zeigt die Lokalisierung der Speicherung der KonfigurationDiese Nummer erscheint auch im Fenster Meters auf der Position (g) Das benutzte Programm kann jederzeit vom Benutzer angezeigt werden
Empty Preset Es ist der Name der der Nummer der Lokalisierung zugeordnet wird wenn keine Einstellung gespeichert ist (leer)
Local preset Es i s t de r Name de r de r Nummer de r Loka l i s i e rung zugeordnet wird wenn eine Konfiguration gespeichert wird
ANMERKUNG = Man kann eine Einstellung mit dem gewuumlnschten Namen mit max 16 Buchstaben nur speichern wenn man die Schnittstelle uumlber den Computer benutzt
Bei der Wahl eines Programms erscheint folgendes Fenster
Anzeige des Namens der dem Programm zugeordnet istUm auf die Anwendung einzuwirken stehen 3 Auswahlmoumlglichkeiten zur Verfuumlgung
Das Programm wird im Speicher des AC 26N gespeichert
Das Programm wird geloumlscht
Das Programm wird geladen und ist bereit fuumlr die Benutzung
Save
Del
Load
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
37
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
38
BESCHREIBUNG DES MENUumlFENSTERS X-Over
Dieses Fenster erlaubt fuumlr jeden Ausgang einen Bassdurchgangsfilter einen Hochdurchgangsfilter oder mittels Kombination von beiden einen Banduumlbergangsfilter zu waumlhlenDer Filter ist ein Linkwitz-Riley wo man die Neigung von 12 dBoct 24dBoct oder 48 dBoct und die entsprechende Schnittfrequenz auswaumlhlen kann
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) AUSGANGSKANAumlLE
Die Steckverbinder am Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) FILTER CROSSOVERDen Filter nach Bedarf waumlhlen Man kann folgendes auswaumlhlen
Dis Kein Filter aktiviert
HP Hochdurchgangsfilter nur den Teil des Audiosignals durchlassen der uumlber der Schnittfrequenz liegt
LP Bassdurchgangsfilter nur den Teil des Audiosignals durchlassen der unter der Schnittfrequenz liegt
Filter-Konfiguration Tiefpass Hochpass
Nichts Dis Dis
Hochpass HP Dis
Tiefpass Dis LP
Bandpass HP LP
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
c) DAumlMPFUNGSNEIGUNGDie Daumlmpfungsneigung des Audiosignals auf der Basis der Verringerung auswaumlhlen die man erreichen moumlchte Je houmlher die Daumlmpfungsneigung bei gleicher Schnittfrequenz desto groumlszliger ist die Signalauswahl Man kann folgendes waumlhlen
12 entsprechend 12 dboct
24 entsprechend 24 dboct
48 entsprechend 48 dboct
d) SCHNITTFREQUENZErlaubt die Durchgangsfrequenz der niederen Frequenzen (Bassdurchgangsfilter) oder der hohen Frequenzen (Hochdruchgangsfilter) einzustellenDie Auswahl des Schnitts bezieht sich auf die Wiedergabe die man erreichen moumlchteDie benutzte Maszligeinheit ist Hz
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
BESCHREIBUNG DES MENUumlFENSTERS Matrix
Erlaubt fuumlr jeden Ausgang das Eingangssignal zu waumlhlen das als Quelle benutzt werden soll
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) AUSGANGSKANAumlLEIdentifizierung des einzustellenden Ausgangskanals
b) IDENTIFIZIERUNG DER EINGAumlNGEDen Signaltyp auswaumlhlen der nach eigener Anforderung jedem einzelnen Ausgang zugeordnet werden soll Man kann folgendes waumlhlen
In A Das Signal wird dem Eingang A zugeordnet
In B Das Signal wird dem Eingang B zugeordnet
In A+B Zuordnung der a lgebra ischen Summe der be iden Eingangssignale A und B
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
BESCHREIBUNG DES MENUumlFENSTERS Option
Erlaubt die Anzeige der Systemeinstellungen wie die Zuordnung der Ein- und Ausgaumlnge Daumlmpfung Displaykontrast und Firmware-Version
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B Src
Diese Option erlaubt die Einstellung des Audio-Signaltyps am Eingang
Analoge Audiosignale (Eingaumlnge A und B)
Digitale Audiosignale (Eingang AESEBU)
DigOut Src
An In =Audiosignale an den analogen Eingaumlngen
Dig In =Audiosignale am digitalen Eingang
OUT 1-2 =Audiosignale an den Ausgaumlngen 1 und 2
OUT 3-4 =Audiosignale an den Ausgaumlngen 3 und 4
OUT 5-6 =Audiosignale an den Ausgaumlngen 5 und 6
Input Mode
An In
Dig In
Indip =
Linked =
Diese Option erlaubt die Audioquelle zu waumlhlen die fuumlr den Steckverbinder AESEBU OUT (digitaler Ausgang) bestimmt ist
Erlaubt die Eingaumlnge zu konfigurieren
Sie sind unabhaumlngig und selbststaumlndig sie unterliegen keinen Verpflichtungen untereinander Sie sind verbunden und funktionieren im Stereo-Modus
Die Kompressoren Filter Verzoumlgerungen die Lautstaumlrke sind bei beiden Kanaumllen identisch
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
39
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
40
Atten PadZeigt an wie der Wahlschalter -6 dB auf der Ruumlckseite eingestellt ist [Ref 5] Dieser Wahlschalter muss aktiviert werden wenn das Level an den analogen Eingaumlngen zu hoch ist Der Wahlschalter wird uumlber die Taste aktiviert im Menuuml gibt es nur eine Anzeige
0dB = Wahlschalter nicht aktiviert
-6dB = Wahlschalter aktiviert
Contrast
10 heller 60 dunkler 100
Fw Vers
Die Eingangssignale sind dieselben wie die Eingangsquelle
Die Eingangssignale werden vom internen Prozessor um -6 dB gedaumlmpft
Erlaubt den Kontrast des LCD-Displays einzustellen um den Unterschied der Helligkeit auf den Installationsort auszurichten Ein deutlicheres Display erlaubt auf korrekte und schnelle Weise innerhalb der Menuumls zu surfenDie Hersteller-Einstellung am Ausgang liegt bei 60
Zeigt die Firmware-Version des Prozessors an
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
41
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
42
TECHNISCHE DATEN
Antwort in FrequenzDynamische GammaCMMRCrosstalkDistorsion
ProzessorFrequenz der DatenausarbeitungAnaloge Converter Verzoumlgerung der VerteilungSpeicherung der Konfigurationen
DisplayTastenBedienungen
Analoger Eingang ndeg2 x XLR (3-poliger Female Stecker)Impedanz des Eingangs gt10KOhmMaximales Level +21dBu ohne PAD
+27dBu bei PAD
Impedanz des Ausgangs 50OhmMaximales Level +21dBu Typ symmetrisch
Typ SPDIF-AESEBU (AES3)
Typ Entsprechend dem Standard des Eingang
Typ
Typ
NETZSPANNUNGABMESSUNGEN (BXHXT)GEWICHT
AUDIO-LEISTUNGEN+- 01dB (20 to 30kHz)116dB typgt 60dB (50 to 10kHz)lt -100dB0002 (1kHz +4dBu)
DIGITALE AUDIO-LEISTUNGEN DSP 2856-bit 48KHz24-bit BURR BROWN15ms32 preset
KONTROLLEN LCD GrafikESC - MENU - FUNCTIONS SELECTIONENTER
EIN-AUSGAumlNGE
Analoger Ausgang ndeg6 x XLR (3-poliger Male Stecker)
Digitaler Eingang ndeg1x XLR (3-poliger female Stecker)
Digitaler Ausgang ndeg1x XLR (3-poliger Male Stecker)
Ein-Ausgang Rdnet ndeg2 x XLR RJ45 (kabel CAT 5) USB Typ B
KONTROLLPARAMETER AUDIOStaumlrke -80dB a +20dB step 01dBVerzoumlgerung Eingang 0 a 729mS step 01 mS
Ausgang 0 a 340mS step 01mSPhasenrotation 0deg - 180deg
KOMPRESSIONSchwelle -80dB a +20dB step 01dBVerhaumlltnis 11 a Inf1 step 001Staumlrke am Ausgang 0dB a 40dB step 01dBAnschlusszeit 1mS a 1000mS step 01mSReleasezeit 1mS a 1000mS step 01mSBeibehaltungszeit 1mS a 1000mS step 01mS
EQUALIZER12 Equalizer fuumlr jeden Ein- und Ausgang
PEQ (parametrischer) Hi-shelf Lo-sheftFrequenz 20Hz a 20KHz step 1HzStaumlrke -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (lediglich PEQ)
FILTER CROSSOVERFilter Linkwitz Riley
HP HochdurchgangsfilterLP Bassdurchgangsfilter
Neigung 12dBoct - 24dBoct - 48dBoctSchnittfrequenz 5Hz a 20KHz step 1Hz
Full-range 100-240Vac 50-60Hz430482x43x130mm 19Kg
AnmerkungenSpezifikationen unterliegen Aumlnderungen ohne Vorankuumlndigung
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
INTRODUCTIONAC26N est un processeur audio numeacuterique pour la gestion de leacutequipement audio conccedilu pour des installations fixes et mobiles Il fonctionne selon une technologie de pointe avec des processeurs agrave 2856bits et des convertisseurs ADDA agrave 24-bits hautes performances Les fonctions du processeur sont les niveaux dentreacutee et de sortie le deacutelai (delay) la polariteacute 12 bandes deacutegalisation par canal dentreacutee et de sortie diffeacuterentes seacutelections de croisement (crossover) et un limiteur hautes performances Le controcircle des filtres a une reacutesolution de 1Hz Les entreacutees et les sorties peuvent ecirctre programmeacutees en plusieurs configurations pour satisfaire tous les besoins AC26N peut ecirctre controcircleacute en temps reacuteel et tous les paramegravetres peuvent ecirctre configureacutes depuis le pupitre frontale et par ordinateur avec interface graphique intuitive accessible via le logiciel laquoDVA Networkraquo et une connexion de reacuteseau deacutedieacutee RDnet ou USBLa mise agrave jour du logiciel pour lUniteacute centrale et DSP par ordinateur portable permet de maintenir le dispositif actualiseacute Il est possible denregistrer et de rappeler 32 configurations preacute-eacutequipeacutees de configuration
Contenu de lemballage - AC26N - Mode demploi- CD logiciel- Cacircble dalimentation
Caracteacuteristiques- 2 entreacutees et 6 sorties avec adressage flexible- Entreacutee et sortie steacutereacuteo AESEBU adressables - DSP 2856-bit- Convertisseurs AD BURR BWOWN 24-bit hautes performances- Freacutequence de reacutesolution des filtres 1 Hz - 12 eacutegaliseurs parameacutetriques pour chaque entreacutee et sortie- 2 filtres de croisement par sortie avec pente seacutelectionnable agrave 122448dBoct- DRC agrave configuration multiple hautes performances pour configuration limiteur
compression pour chaque entreacutee et sortie- Niveau reacuteglable en dB polariteacute et deacutelai pour chaque entreacutee et sortie- Mise agrave jour du micrologiciel par lordinateur- Affichage graphique agrave cristaux liquides- 32 preacutereacuteglages enregistrables par lutilisateur- Interface USB pour le controcircle et la configuration par ordinateur- Interface RDnet permettant de controcircler jusquagrave 256 dispositifs agrave distance
PC
PC
RDNETcontrol(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FONCTIONS DE LA FACE AVANT
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
COMMANDES ET FONCTIONS1) AFFICHAGE
Laffichage graphique agrave cristaux liquides permet de visualiser et deacutediter les informations de lAC26N sans utiliser lordinateur Le contraste peut ecirctre configureacute dans le menu principal
2) MANETTE Functions Selector et Push EnterCe controcircle permet de se deacuteplacer de seacutelectionner et de modifier les paramegravetres dans les menus affichables agrave leacutecranRotation de la manette (Functions Selectors)- permet de se deacuteplacer sur les diffeacuterentes pages du menu - permet de modifier les paramegravetres seacutelectionneacutesPression de la manette (Push Enter)- permet de seacutelectionnervalider les paramegravetres
3) Bouton ESC Ce controcircle permet de quitter les menus afficheacutes ou de revenir agrave la visualisation preacuteceacutedente
4) Bouton Menu Ce controcircle permet dacceacuteder directement au menu principal
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
Fra
nccedilais
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
43
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
Fra
nccedilais
44
DVA Network
AC26N est eacutequipeacute dune interface de reacuteseau proprieacutetaire deacutenommeacutee RDNET au moyen de laquelle il est possible de sinterfacer agrave lordinateur agrave travers un peacuteripheacuterique (RDNET control)
Pour cela un protocole de communication a eacuteteacute deacuteveloppeacute avec lequel il est possible de recevoir et denvoyer les donneacutees ce branchement permet de faire le monitorage en temps reacuteel des paramegravetres du diffuseur comme puissance de sortie tempeacuterature de lamplificateur eacutetat du limiteur etc Il est aussi possible de seacutelectionner diffeacuterentes eacutegalisations ou den creacuteer de nouvelles et de reacutegler les niveaux de volume souhaiteacutes au moyen dun plug-in approprieacute
On conseille de teacuteleacutecharger gratuitement le logiciel DVA Network directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
DVA USB Manager
On conseille de teacuteleacutecharger gratuitement le logiciel DVA USB Manager directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
Le micrologiciel du module amplificateur peut ecirctre remis agrave jour par le port USBPour rendre cette mise agrave jour possible et facile un programme speacutecifique a eacuteteacute deacuteveloppeacute
DOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
CONNEXIONS DU PANNEAU ARRIEgraveRE
1586 75 141210 11 13 169 17
14) Connecteur ldquo USBrdquoCe connecteur USB (type B) permet de connecter le processeur agrave un ordinateur pour le controcircle et la mise agrave jour du micrologiciel via un programme deacutedieacute (DVA Network)
15) PRISE DALIMENTATION MAINSPermet la connexion du cacircble dalimentation fourni de seacuterie
16) PORTE-FUSIBLE FUSELogement pour fusible de ligne
17) INTERRUPTEUR GENERAL POWERLinterrupteur permet de mettre en marche ou deacuteteindre le controcircleur audio
COMMANDES ET FONCTIONS
5) SELECTEUR ldquo-6dBrdquoLe seacutelecteur permet de reacuteduire de 6dB les niveaux dentreacutee analogiques XLR [6] tout en compensant les niveaux eacuteleveacutes de sortie des meacutelangeurs ou dautres dispositifs audio Quand la barre du niveau de signal des entreacutees sur laffichage [1] reste au maximum cela indique que le niveau du signal entrant est eacuteleveacute Il est alors conseilleacute dutiliser latteacutenuation -6dBIl est possible de veacuterifier quand le seacutelecteur est activeacute par le menu Option
6) CONNECTEURS DENTREE ldquoArdquo ET ldquoBrdquoEntreacutees eacutequilibreacutees au niveau de la ligneIls sont en mesure daccepter des connecteurs XLR macircles
7) CONNECTEURS DE SORTIE ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo ET ldquo6rdquoSorties eacutequilibreacutees au niveau de la ligne Ils sont en mesure daccepter des connecteurs XLR femelles
Prendre garde agrave brancher convenablement les sorties sur les diffuseurs ou les amplificateurs en fonction des configurations de chaque canal pour eacuteviter des deacutegacircts et des problegravemes de fonctionnement
Section ldquoAESEBUrdquo
8) CONNECTEUR DENTREE INOutre les entreacutees audio analogiques une entreacutee audio numeacuterique SPDIF-AESEBU (AES3) a eacuteteacute preacutevue et peut ecirctre seacutelectionneacutee par le menu de setupLentreacutee requiert une connexion eacutequilibreacutee en utilisant un connecteur XLR avec un cacircble agrave 3 conducteurs de 110ohm torsadeacute
9) CONNECTEUR DE SORTIE OUTCe connecteur permet de relancer le signal audio dans les entreacutees analogiques ou numeacuteriques ou sur les sorties La source doit ecirctre reacutegleacutee par le menu OptionLa connexion sera conforme agrave la mecircme norme que lentreacutee [reacutef8]
Section ldquoRDNETrdquo
10) CONNECTEUR DENTREE DATA INPUTConnecteur RJ45 entreacutee de donneacutees
11) CONNECTEUR DE SORTIE DATA LINKConnecteur RJ45 sortie de donneacutees pour la connexion de seacuterie en cascade
12) VOYANT LUMINEUX ONCe voyant de couleur verte sallume uniquement quand lAC26N a reconnu et est connecteacute agrave luniteacute principale RDNET par lordinateur
13) VOYANT LUMINEUX ACTIVECe voyant de couleur jaune clignote quand une transmission des donneacutees est active entre RDNET et le dispositif
PUSH
P SHU
SHPU
P SHU
PUSH
CONNEXIONS
Audio analogiquesLes connexions eacutequilibreacutees permettent de reacuteduire au minimum le bruit provoqueacute par les cacircbles et dutiliser de longs cacircblesCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLe connecteur XLR doit ecirctre brancheacute avec la broche 1 agrave la masse la broche 2 au chaud (+) et la broche 3 au froid (-) En cas de cacircble blindeacute brancher le blindage agrave la broche 1Les cacircbles de connexion XLR-XLR et XLR-Jack14(63mm) peuvent semployer pour la connexion agrave lAC26N
12
3
Entreacutee
Entreacutee
XLR - femme
XLR - femme
1 2
3
Sortie
Sortie
XLR - Macircle
XLR - Macircle
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2 = Point chaudPhase +VE
Broche 3 =Point froidPhase -VE
Broche 3 =Point froidPhase -VE
Anneau
Manchon
Pointe Point chaudPhase +VE
Anneau = Point froidPhase -VE
ManchonB Masselindeacute
Pointe
Les connexions deacuteseacutequilibreacutees peuvent semployer mecircme si le bruit provoqueacute par les cacircbles augmente Les cacircbles ne peuvent deacutepasser 5m de longCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLes connexions deacuteseacutequilibreacutees peuvent abaisser le niveau du signal entrant de 6dB Pour remeacutedier agrave cet inconveacutenient il faut brancher la broche 3 agrave la masse mecircme si cela augmente le bruit
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
45
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
46
12
3
1 2
3
Pointe Manchon
Pointe = Signal
Broche 3 = Link to Pin 1
Broche 3 = Link to Pin 1
ManchonB Masselindeacute
Audio numeacuteriques (AESEBU)
AESEBU (protocole AES3) est une entreacutee eacutequilibreacutee isoleacutee eacutelectriquement agrave laide dun transformateur Elle permet demployer deux canaux audio dans un seul cacircble bipolaire blindeacute Les caracteacuteristiques du cacircble doivent ecirctre de 3 pocircles impeacutedance 100ohm torsadeacute et blindeacute avec connecteur XLR (AES3 standard)
RJ 45
|1|2|3|4|5|6|7|8|
RDnet
Chaque port RDNet des Control 2 et Control 8 peut ecirctre brancheacute agrave un maximum de 32 dispositifs compatibles placeacutes en cascade Dans lexemple suivant le port de luniteacute de controcircle RDNET CONTROL 2 est relieacute agrave lentreacutee DATA INPUT dun AC26N dont la sortie parallegravele DATA LINK est envoyeacutee agrave lentreacutee de lAC26N successif Dans lexemple [n] est un nombre compris entre 3 et 32 (limite maximale des dispositifs que lon peut relier agrave un sous-reacuteseau)
La longueur totale du cacircble CAT5 dun sous-reacuteseau NE peut PAS deacutepasser 900 megravetres
Le connecteur doit ecirctre relieacute comme 1 ndash disponible pour dautres fonctions (par exemple audio +) 2 ndash disponible pour dautres fonctions (par exemple audio )3 ndash disponible pour dautres fonctions (par exemple masse analogique)4 ndash masse numeacuterique5 ndash masse numeacuterique6 ndash disponible pour dautres fonctions (par exemple alimentation)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
MISE EN MARCHE
Lors de la mise en marche du dispositif linitialisation deacutebute et dure quelques secondes Leacutecran affiche le modegravele le logo et la barre de progression du chargement du programme
En fin de processus dinstallation leacutecran affiche la fenecirctre du menu Meters Pour connaicirctre les indications en deacutetail consulter le paragraphe DESCRIPTION FENETRE MENU Meters
LAC26N est precirct agrave lemploi
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION ET VISUALISATION
Pour entrer dans la fenecirctre du menu principal il faut pousser sur la touche MENU ( ) agrave lavant du dispositifDune page quelconque du menu en poussant sur la touche ESCrdquo ( ) on revient automatiquement sur la page-eacutecran preacuteceacutedente
MENU PRINCIPAL
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Le processeur contient six menus Ils montrent etou configurent les paramegravetres du systegravemeLes menus principaux sont
Meters Visualisation des niveaux des entreacutees et des sorties visualisation du programme utiliseacute et eacutetat mute rapide
Preset Meacutemoriser enregistrer et eacuteliminer les configurations du systegraveme
Matrix seacutelectionner les sorties en fonction du signal entrant
Ch Job configuration de chaque signal
X-Over configurer les freacutequences de coupure et les types de filtres pour chaque sortie
Option attribution des entreacutees et des sorties contraste daffichage la version du micrologiciel les entreacutees et dautres options
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
47
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
48
DESCRIPTION DE LA FENETRE MENU Metersrdquo
Cette fenecirctre permet de visualiser les configurations et leacutetat geacuteneacuteral des entreacutees et des sorties la version du programme utiliseacute son eacutetat et le mode de pilotage du systegraveme
Les menus et les options afficheacutees peuvent se seacutelectionner en tournant la manette ldquoFUNCTIONS SETECTORrdquo ( ) Pour avoir accegraves agrave linteacuterieur de la seacutelection il faut mettre le paramegravetre souhaiteacute en eacutevidence et pousser sur la manette ldquoPush Enterrdquo ( | ) Il faut en faire de mecircme pour seacutelectionner etou modifier les options dans les commandes du menu
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositifAvec des signaux dentreacutee numeacuteriques les indications ldquoArdquo et ldquoBrdquo correspondent agrave lentreacuteeEn tournant la manette ldquoFUNCTIONS SELECTORrdquo [2] on fait deacutefiler en mode cyclique les canaux dentreacutee de sortie et lindication de mute geacuteneacuteral (d) le canal seacutelectionneacute est mis en eacutevidence
b) BARRE DE NIVEAU DE COMPRESSIONMUTE CANAL
COMPRESSION DE SIGNALLa compression du signal est visualiseacutee par le deacutefilement de la barre de droite de haut en bas
MUTE Chaque canal peut ecirctre placeacute en mute Seacutelectionner le canal et pousser sur la manette ldquoPush Enterrdquo [2] pour valider le changement deacutetat Lindication du canal sera remplaceacutee par la lettre M et la barre sera totalement mise en eacutevidencePour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterations
c) BARRE DE NIVEAU DE SIGNALLindication du niveau de chaque canal est signaleacutee par le deacutefilement de la barre de gauche
d) MUTE GENERALIl est possible de mettre simultaneacutement toutes les entreacutees et les sorties en mute Tourner la manette ldquoFUNCTIONS SELECTORrdquo seacutelectionner la lettre M et pousser sur la manette Push EnterPour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterationsLe mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) MODES DE COMMANDEIl affiche le mode dutilisation etou les dispositifs qui sont relieacutes agrave lAC26N
Local = utilisation autonome Aucune connexion agrave un dispositif exteacuterieur
NET = relieacute directement au reacuteseau deacutedieacute RDNet et agrave lordinateur
USB = relieacute directement agrave un ordinateur par cacircble USB
f) INDICATION DETAT DE PARAMETRAGECette indication permet de constater si un ou plusieurs paramegravetre(s) du programme chargeacute aont eacuteteacute modifieacute(s) par rapport au dernier sauvetage
= programme dorigine
= programme avec des paramegravetres modifieacutes
g) PROGRAMME CONFIGURELe chiffre indique le programme chargeacute et utiliseacute par le systegraveme agrave lemplacement de sauvetage Consulter le menu de Preset pour de plus amples deacutetails
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
DESCRIPTION DE LA FENETRE MENU Ch Job
Cette fenecirctre permet dafficher la configuration de chaque canal
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) NIVEAU DU SIGNALIndique le gain du signal Laugmentation de lintensiteacute dun signal est libelleacutee en deacutecibel (dB) Le paramegravetre peut ecirctre seacutelectionneacute de -8000dB agrave +2000dB avec des pas de 001dB Une augmentation de 6dB est eacutegale approximativement au redoublement agrave leacutechelle lineacuteaire du niveau du signal sous tensionAvec un gain supeacuterieur agrave 0dB le signal est amplifieacute tandis quavec un gain infeacuterieur agrave 0dB le signal est atteacutenueacute
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
49
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
50
c) DELAI DU SIGNAL (DELAY)Le signal audio reproduit peut ecirctre retardeacute pour permettre lalignement acoustique Cela compense les diffeacuterentes positions des diffuseurs pendant linstallation et la reproduction sonore Il se libelle en mS Le paramegravetre peut ecirctre seacutelectionneacute de 00mS agrave 729mS avec un pas de 01mSPour aligner un signal audio il est possible dutiliser la formule suivante
Deacutelai = (GAPx1000)344
Deacutelai = ms (en millisecondes)GAP = distance du diffuseur du point de reacutefeacuterence (en megravetres)Vitesse du son = 344ms
d) MUTEChaque canal peut ecirctre placeacute en mute La mecircme commande peut ecirctre activeacutee dans la fenecirctre du menu meters NB Le mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) PhasePermet la rotation de phase de 180deg par rapport au signal entrantCette rotation permet loptimisation surtout des basses freacutequences dans les installations complexes
f) EGALISATIONCette commande ouvre la fenecirctre du menu deacutegalisation de chaque canal Elle sert surtout pour corriger une ou plusieurs freacutequences qui doivent ecirctre atteacutenueacutees ou augmenteacutees
M M
LAC26N gegravere 12 filtres par canal dentreacutee et sortie avec trois types de configurations diffeacuterentes - Leacutegaliseur PEQ (peaking equalizer) est ideacuteal pour identifier isoler et
corriger une seule plage de freacutequences bien deacutetermineacutee Toutes les freacutequences passent mais il augmente ou diminue uniquement celles autour de la freacutequence centrale pour une bande preacutecise et un gain deacutefini
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessus de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessous de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
f Numeacuterotation des 12 filtres disponibles pour cette entreacutee ou cette sortie1
f Le type de filtre est afficheacute 2
Dis Deacutesactiveacute (absent)
PEQ Peaking equlizer
Sh H Filtre high-shelf
Sh L Filtre high-shelf
Exemples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
REMARQUELe paramegravetre Bw deacutetermine le champ de freacutequences adjacent agrave la freacutequence configureacutee ougrave est activeacute le filtre Plus la valeur Bw est eacuteleveacutee plus vaste est le champ de freacutequences (1Bw=1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONCette commande ouvre la fenecirctre du menu de compression de chaque canal
g1) TresholdIdentifie le seuil ougrave commence le rapport de compression La valeur de base 11
g2) RatioIndique le rapport de conversion entre le signal entrant et le signal sortant
g3) Post Gain Attach Release HoldCes donneacutees deacutependent du rapport de conversion que lon veut obtenir - Post Gain est le gain de sortie- Attack est le temps dattaque - Release est le temps de relacircchement- Hold est le temps de maintien
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
52
DESCRIPTION DE LA FENETRE MENU Preset
Cette fenecirctre permet de meacutemoriser jusquagrave 32 configurations dans lAC26NLe fabricant fournit le systegraveme avec un programme configureacute et enregistreacute en position 0 et non susceptible deacutecrasement
032 Elle indique lemplacement de sauvetage de la configurationCe numeacutero apparaicirct dans la fenecirctre Meters en position (g) A tout moment le programme utiliseacute peut ecirctre afficheacute par lutilisateur
Empty Preset Cest le nom qui est associeacute au numeacutero de lemplacement quand aucune configuration (vide) nest enregistreacutee
Local preset Local preset est le nom qui est associeacute au numeacutero de lemplacement quand on enregistre une configuration NB = Il est possible denregistrer une configuration avec lenom souhaiteacute de 16 lettres tout au plus agrave condition que lonutilise linterface via lordinateur
Le nom du programme assigneacute est indiqueacutePour toucher agrave lapplication 3 choix soffrent agrave vous
Save Le programme est enregistreacute en meacutemoire de lAC26N
Del Le programme est effaceacute
Load Le programme est chargeacute et precirct agrave lemploi
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
51
DESCRIPTION DE LA FENETRE MENU X-Over
Cette fenecirctre permet de seacutelectionner un filtre passe bas un filtre passe haut ou par la combinaison des deux de creacuteer un filtre passe bande pour chaque sortieLe filtre actif est un Linkwitz-Riley qui permet de seacutelectionner la pente de 12dBoct 24dBoct ou 48dBoct et sa freacutequence de coupure
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) CANAUX DE SORTIE
Les connecteurs de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) FILTRE CROSSOVERSeacutelectionner le filtre selon les besoins Il est possible de seacutelectionner
Dis Aucun filtre activeacute
HP Filtre passe-haut laisse passer uniquement la partie de signal audio supeacuterieure agrave la freacutequence de coupure
LP Filtre passe-bas laisse passer uniquement la partie de signal audio infeacuterieure agrave la freacutequence de coupure
Configuration du filtre Passe-haut Passe-bas
Rien Dis Dis
Passe-haut HP Dis
Passe-bas Dis LP
Passe-bande HP LP
12dBoct
24dBoct
Hz
dB
Ga
in 48dBoct
12dBoct
24dBoct
Hz
dB
Ga
in
48dBoct
c) PENTE DATTENUATIONSeacutelectionner la pente datteacutenuation du signal audio en fonction de la diminution que lon veut obtenir Plus la pente datteacutenuation est eacuteleveacutee agrave eacutegaliteacute de freacutequence de coupure plus eacuteleveacutee sera la seacutelection du signal Il est possible de seacutelectionner
12 correspond agrave 12dboct
24 correspond agrave 24dboct
48 correspond agrave 48dboct
d) FREQUENCE DE COUPUREElle permet de reacutegler la freacutequence de passage des freacutequences infeacuterieures (filtre passe-bas) ou des freacutequences supeacuterieures (filtre passe-haut) uniquementLe choix de la coupure deacutepend de la reproduction que lon veut obtenirLuniteacute de mesure utiliseacutee est lHz
Hz
Hz
dB
dB
Ga
in
f0
f0
0dB0dB
0dB
-6dB
freacutequence
freacutequence
freacutequence
freacutequence
Ga
in
f0
0dB
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
53
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
54
DESCRIPTION DE LA FENETRE MENU Matrix
Elle permet de seacutelectionner le signal entrant agrave utiliser comme source pour chaque sortie
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) CANAUX DE SORTIEIdentification du canal sortant agrave reacutegler
b) IDENTIFICATIONS DES ENTREESSeacutelectionner le type de signal agrave associer agrave chaque sortie en fonction des besoins Il est possible de seacutelectionner
In A Le signal entrant A est associeacute
In B Le signal entrant B est associeacute
In A+B La somme algeacutebrique des deux signaux entrants A et B est associeacutee
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
DESCRIPTION DE LA FENETRE MENU Option
Permet dafficher les reacuteglages du systegraveme comme lassignation des entreacutees et des sorties latteacutenuation le contraste de laffichage et la version du logiciel
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcCette option permet de reacutegler le type de signal audio entrant
An In =signaux audio analogiques (entreacutees ldquoArdquo et ldquoBrdquo)
Dig In =signaux audio numeacuteriques (entreacutee AESEBU)
DigOut SrcCette option permet de seacutelectionner la source audio qui sera adresseacutee sur le connecteur AESEBU OUT (sortie numeacuterique)
An In = signaux audio des entreacutees analogiques
Dig In =signaux audio sur lentreacutee numeacuterique
OUT 1-2 = signaux audio sur les sorties 1 et 2
OUT 3-4 = signaux audio sur les sorties 3 et 4
OUT 5-6 = signaux audio sur les sorties 5 et 6
Input ModePermet de configurer les entreacutees
Indip = sont indeacutependantes et autonomes Ne sont soumises agrave aucun type de lien
Linked = sont unies et fonctionnent en mode steacutereacuteo Les compresseurs les filtres les deacutelais le volume sont identiques pour les deux canaux
Atten PadIndique le mode de reacuteglage du seacutelecteur ldquo-6dBrdquo placeacute agrave larriegravere [reacutef 5] Il faut activer ce seacutelecteur quand les niveaux dentreacutee analogiques sont trop eacuteleveacutes Le seacutelecteur sactive uniquement par le bouton Dans le menu il sagit dune simple visualisation
0dB = seacutelecteur non activeacute Les signaux dentreacutee sont identiques agrave la source entrante
-6dB = seacutelecteur activeacute Les signaux entrants sont atteacutenueacutes de -6dB par le processeur interne
ContrastIl permet de reacutegler le contraste de laffichage agrave cristaux liquides pour compenser la diffeacuterence de luminositeacute avec le lieu dinstallation Une plus grande clarteacute de laffichage permet de naviguer convenablement et rapidement dans les menusLe reacuteglage agrave la sortie de lusine du fabricant est de 60
10 plus clair 60 plus fonceacute 100
Fw VersIndique la version du logiciel du processeur
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
55
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
56
DONNES TECHINIQUES
PERFORMANCES AUDIOReacuteponse en freacutequence +- 01dB (20 to 30kHz)Plage dynamique 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsion 0002 (1kHz +4dBu)
PERFORMANCES AUDIO NUMERIQUES Processeur DSP 2856-bit Freacutequence de traitement des donneacutees 48KHzConvertisseurs analogiques 24-bit BURR BROWNDeacutelai de propagation 15msMeacutemorisations des configurations 32 preset
CONTROLES Affichage LCD graficoBoutonsCommandes ESC - MENU - FUNCTIONS SELECTION
ENTERENTREESSORTIESEntreacutee analogique ndeg2 x XLR (3 broches femelle)
Impeacutedance dentreacutee gt10KOhmNiveau maximum +21dBu senza PAD
+27dBu con PADSortie analogique ndeg6 x XLR (3 broches macircle )
Impeacutedance de sortie 50OhmNiveau maximum +21dBuType Balanceacute
Entreacutee numeacuterique ndeg1x XLR (3 broches femelle)Type SPDIF-AESEBU (AES3)
Sortie numeacuterique ndeg1x XLR (3 broches macircle )Type conforme agrave la norme de lentreacutee
EntreacuteesSortie Rdnet ndeg2 x XLR RJ45 (cacircble CAT 5)USB Type B
PARAMETRES DE CONTROLE DU SONGain -80dB a +20dB eacutetape 01dBDeacutelai Entreacutee 0 a 729mS eacutetape 01 mS
Sortie 0 a 340mS eacutetape 01mSRotation de phase 0deg - 180deg
COMPRESSIONSeuil -80dB a +20dB eacutetape 01dBRapport 11 a Inf1 eacutetape 001Gain agrave la sortie 0dB a 40dB eacutetape 01dBTemps dattaque 1mS a 1000mS eacutetape 01mSTemps de relacircchement 1mS a 1000mS eacutetape 01mSTemps de maintien 1mS a 1000mS eacutetape 01mS
EGALISEURS12 eacutegaliseurs pour chaque entreacutee et sortieType PEQ (parameacutetrique) Hi-shelf Lo-sheft
Freacutequence 20Hz a 20KHz eacutetape 1HzGain -30dB a +15dB eacutetape 001dBBande 005dB a 2dB eacutetape 001dB (uniquement pour PEQ)
FILTRES CROSSOVERFiltre Linkwitz Riley
Type HF high-shelfLF low-shelf
Pente 12dBoct - 24dBoct - 48dBoctFreacutequence de coupure 5Hz a 20KHz eacutetape 1Hz
ALIMENTATION Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)POIDS 19Kg
Remarques Speacutecifications sujettes agrave modifications sans preacuteavis
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
2 VIE ATTIVO2 WAY ACTIVE
3 VIE PASSIVO3 WAY PASSIVE
L
L
A
A
HIGH L
MID L
LOW HIGHMID RHIGHMID L
LOW L
HIGH R
MID R
LOW R
R
R
B
B
1
1
2
2
3
3
456
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
Menu Matrix configurationMatrix
57 58
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
EROUIG ATRIX TNM
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
OU
TP
UT
1
OU
TP
UT
2
OU
TP
UT
3
OU
TP
UT
4
OU
TP
UT
5
OU
TP
UT
6
AE
S-E
BU
OU
TP
UT
INP
UT
A
AE
S-E
BU
INP
UT
INP
UT
B
D D D D D D
D D
A A A A A A
A SA
MP
LE
RA
TE
CO
NV
A
LIN
KA
BL
E
SC
HE
MA
A B
LO
CC
HI -
BL
OC
K D
IAG
RA
MB
LO
CK
SC
HA
LT
BIL
D -
SC
HE
MA
S F
ON
CT
ION
NE
LS
LINE ARRAY SUB MONO ATTIVO
LINE ARRAY SUB MONO ACTIVEINGRESSI - INPUT
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
L
L
L
A
A
A
AESEBU IN
AESEBU IN
AESEBU IN
AESEBU OUT
AESEBU IN
AESEBU IN
AESEBU OUT
R
R
R
LR
B
B
B
123456
HIGHMID L
HIGHMID L HIGHMID R
HIGHMID R
LOW L LOW R
LAYER
DISPLAY MEMORY
FADER MODE
LAYER
DISPLAY MEMORY
FADER MODE
Ingresso ANALOGICO
ANALOG Input
Collegamento in cascata
Link connections
Ingresso DIGITALE
DIGITAL inputA B
BALANCED AUDIO INPUTS
-6dB
PUSH PUSH
IN OUT
AES EBUPUSH
Oppure
or
Oppure
or
Menu Option configurationOption
Menu Option configurationOption Menu Option configurationOption
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type Analog
AES out An In
Input type Analog
AES out An In
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
59 60
InA-B Src Dig InInA-B Src Dig InInA-B Src An InInA-B Src An In
frequenzaHz
dB
Gu
ad
ag
no
60 200 2800
0dB0dB
-6dB
Esempio di un sistema a 3-vie
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
Out 1 Out 2 Out 3
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Esempio di un sistema a 3-vie
61 62
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
26NAC 26NAC
R TE
DO
R
MO LEU O R CE S
E O TR L A
S O
O C ND I P
P hsuernE t
o su cti nF nel rS e tc o
E CSME UN
IGCHTE OL SN EOBd
ocaL l
M
0
484
467
430
44
31
75
12
7
DIMENSIONI DIMENSIONSABMESSUNGEN DIMENSIONS
MENU DESCRIPTION - X-OVER
This window allows to select for each output a low pass filter a high pass filter or create a band-pass filter via the combination of bothThe available filter is a Linkwitz-Riley where it is possible to select slopes of 12 dBoct 24 dBoct or 48 dBoct and their cut-off frequency
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) OUTPUT CHANNELS
The output connectors are identified by the same information provided on the screen printing located on the device rear side
b) CROSSOVER FILTERSelect the filter according to needs It is possible to select
Dis No filter enabled
HP High-pass filter set it to allow only the part of audio signal above the cut-off frequency
LP Low-pass filter set to allow only the part of audio signal below the cut-off frequency
Filter configuration Low-pass High-pass
Nothing Dis Dis
High-pass HP Dis
Low-pass Dis LP
Band-pass HP LP
12dBoct
24dBoct
Hz
dB
48dBoct
12dBoct
24dBoct
frequency
frequency
frequency
frequency
Hz
dB
48dBoct
c) ATTENUATION SLOPESelect the attenuation slope of the audio signal on the basis of the desired attenuation The higher the attenuation slope at the same cut-off frequency the greater the signal selection It is possible to select
12 equal to 12 dBoct
24 equal to 24 dBoct
48 equal to 48 dBoct
d) CUT-OFF FREQUENCYTo set the passing frequency for the lower frequencies only (low-pass filter) or the higher frequencies only (high-pass filter)The choice of the cut-off depends on the desired sound reproductionThe unit of measurement used is Hz
Hz
Hz
dB
dB
Ga
inG
ain
Ga
inG
ain
f0
f0
0dB0dB
0dB
-6dB
-6dB
0dB
0dB
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
26
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
25
MENU DESCRIPTION - MATRIX
For each output it allows to select the input signal to use as the source
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) OUTPUT CHANNELSIdentification of the output channel to set
b) IDENTIFICATIONS OF THE INPUTSIt selects the type of signal to match each output as needed It is possible to select
In A Associated with the input signal ldquoArdquo
In B Associated with the input signal ldquoBrdquo
In A+B Associated with the algebraic sum of the two input signals ldquoArdquo and ldquoBrdquo
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
MENU DESCRIPTION - OPTION
Allows to display the system settings such as the allocation of the inputs and outputs attenuation display contrast and firmware version
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcThis option allows to set the type of input audio signal
An In = Analog audio signals (inputs A and B)
DigIn = Digital audio signals (AESEBU input)
DigOut SrcThis option allows to select the audio source that will be forwarded to the connector AESEBU OUT (digital output)
An In = Audio signals available at analog inputs
Dig In = Audio signals available at digital inputs
OUT 1-2 = Audio signals available on outputs 1 and 2
OUT 3-4 = Audio signals available on outputs 3 and 4
OUT 5-6 = Audio signals available on outputs 5 and 6
Input ModeIt allows to configure the inputs
Indip = They are independent not subject to constraints of any kind between them
Linked = They are connected and work in stereo mode Compressors filters delays volume are identical for the two channels
Atten PadIt shows how to set the -6 dB switch located on the rear side [Ref 5] It is necessary to activate this selector when the analog input levels are too high The selector can be activated only by means of the button the menu is for display only
0 dB = Selector not activated The input signals are the same as the input source
-6 dB = Selector activated The input signals are attenuated by -6 dB with reference to the inner
processor
ContrastAllows to adjust the LCD display contrast to compensate for the brightness difference at the installation sites Greater display brightness allows to navigate correctly and quickly within the menuThe manufacturer output setting is 60
10 More bright 60 More dark 100
Fw VersIt shows the processor firmware version
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
28
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
27
TECHINICAL SPECIFICATION
AUDIO PERFORMANCEFrequency Response +- 01dB (20 to 30kHz)Dynamic Range 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistortion 0002 (1kHz +4dBu)
DIGITAL AUDIO PERFORMANCE Processor DSP 2856-bit Data processing Frequency 24-bit BURR BROWNAnalog converters 24-bit BURR BROWNPropagation Delay 15msStoring configurations 32 preset
CONTROLS Display LCD graficoButtonsControls ESC - MENU - FUNCTIONS SELECTION
ENTERINPUTSOUTPUTSAnalog Input ndeg2 x XLR (3 pole female)
Input impedance gt10KOhmMaximum Level +21dBu senza PAD
+27dBu con PADAnalog Output ndeg6 x XLR (3 pole male)
Output impedance 50OhmMaximum Level +21dBu Type Balanced
Digital Input ndeg1x XLR (3 pole female)Type SPDIF-AESEBU (AES3)
Digital Output ndeg1x XLR (3 pole male)Type Compliant with the input standard
RDnet InputsOutput ndeg2 x XLR RJ45 (CAT 5 cable)USB Tipo B
SOUND CONTROL PARAMETERSGain -80dB a +20dB step 01dBDelay
Input 0 a 729mS step 01 mSOutput 0 a 340mS step 01mSPhase Rotation 0deg - 180deg
COMPRESSIONThreshold -80dB a +20dB step 01dBRatio 11 a Inf1 step 001Output gain 0dB a 40dB step 01dBAttack time 1mS a 1000mS step 01mSRelease time 1mS a 1000mS step 01mSHold time 1mS a 1000mS step 01mS
EQUALIZERS12 equalizers for each input and outputType PEQ (parametrico) Hi-shelf Lo-sheft
Frequency 20Hz a 20KHz step 1HzGain -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (only with PEQ)
CROSSOVER FILTERSFilter Linkwitz Riley
Type HP High-pass LP Low-pass
Slope 12dBoct - 24dBoct - 48dBoctCUT-OFF FREQUENCY 5Hz a 20KHz passo 1Hz
POWER SUPPLY Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)
1719x17x51 inch (WxHxD)WEIGHT 19Kg
(42 lbs)Note Specifications subject to change without notice
EMI CLASSIFICATIONAccording to the standards EN 55103 this equipment is designed and suitable to operate in E3 (or lower E2 E1) Electromagnetic environments
EINLEITUNG
Verpackungsinhalt
Eigenschaften
AC26N ist ein digitaler Audio-Prozessor fuumlr die Verwaltung von Audio-Systemen der fuumlr feste und mobile Installationen entwickelt wurde AC26N benutzt die modernste Technologie mit 2856 bit-Prozessoren und 24-bit-ADDA-Wandlern mit hoher Leistungsfaumlhigkeit Die verfuumlgbaren Funktionen des Prozessors sind Ein- und Ausgangsstufen Verzoumlgerung (delay) Polaritaumlt 12 Equalizer-Frequenzen fuumlr Ein- und Ausgangskanal viele Crossover-Wahlmoumlglichkeiten und Limiter mit hoher Leistung Die Filter-Kontrolle hat eine Aufloumlsung von 1 Hz Die Ein- und Ausgaumlnge koumlnnen mit unterschiedlichen Einstellungen geregelt werden um allen Anforderungen gerecht zu werden AC26N kann in Echtzeit kontrolliert werden und jeder Parameter kann am Frontpaneel und vom Computer mit intuitiver graphischer Schnittstelle mittels Software DVA Network zugaumlnglich und einer Netzverbindung RDnet oder uumlber USB eingestellt werdenDie SW-Aktualisierung fuumlr CPU und DSP uumlber PC erlaubt die Vorrichtung auf dem aktuellen Stand zu halten Man kann 32 vorgesehene Konfigurationen speichern und aufrufen
- AC26N - Bedienungsanleitung- Software-CD- Versorgungskabel
- 2 Ein- und 6 Ausgaumlnge mit flexibler Adressierung- Adressierbarer Stereo-Ein- und Ausgang AESEBU - DSP 2856-bit- AD-Wandler BURR BROWN 24-bit mit hoher Leistungsfaumlhigkeit- Aufloumlsungsfrequenz der Filter 1 Hz - 12 parametrische Equalizer fuumlr jeden Ein- und Ausgang- 2 Crossover-Filter fuumlr jeden Ausgang mit auswaumlhlbarer Neigung 122448dBoct- DRC Multikonfiguration mit hoher Leistungsfaumlhigkeit fuumlr die Konfiguration des
Limitersder Kompression jedes Ein- und Ausgangs- Einstellbare dB-Stufe Polaritaumlt und Verzoumlgerung (delay) fuumlr jeden Ein- und Ausgang- Firmware-Aktualisierung uumlber PC- Graphisches LCD-Display- 32 Voreinstellungen vom Benutzer einstellbar- USB-Schnittstelle fuumlr die Kontrolle und Konfiguration mit dem Computer- Schnittstelle RDnet welche erlaubt bis zu 256 fern liegende Vorrichtungen
zu kontrollieren
PC
PC
RDNET control(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FUNKTIONEN VORDERSEITE
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
BEDIENUNGEN UND FUNKTIONEN
1) DISPLAYDas graphische LCD-Display erlaubt die Informationen des AC26N ohne einen Computer zu benutzen anzuzeigen und zu editieren Der Kontrast kann im Hauptmenuuml eingestellt werden
2) DREHGRIFF Functions Selector UND Push EnterDiese Kontrolle erlaubt sich in den Menuumls auf dem Display zu bewegen und die Parameter auszuwaumlhlen und zu veraumlndernDrehung des Drehgriffes (Functions Selectors)- Man kann sich innerhalb der verschiedenen Menuumlseiten bewegen- Erlaubt die Veraumlnderung der ausgewaumlhlten ParameterDruck des Drehgriffes (Push Enter)- Erlaubt die AuswahlBestaumltigung der Parameter
3) Taste ldquoESCrdquo Diese Kontrolle erlaubt die angezeigten Menuumls zu verlassen oder zur vorherigen Anzeige zuruumlckzukehren
4) Taste ldquoMenuumlrdquo Diese Kontrolle erlaubt den direkten Zugang zum Hauptmenuuml
Deuts
chD
euts
chB
ed
ien
un
gsan
leit
un
gB
ed
ien
un
gsan
leit
un
g
29
Deuts
chD
euts
chB
ed
ien
un
gsan
leit
un
gB
ed
ien
un
gsan
leit
un
g
30
DVA USB Manager
Die Firmware des Verstaumlrkermoduls kann uumlber den USB-Anschluss aktualisiert werdenUm diesen Vorgang zu ermoumlglichen und zu vereinfachen wurde ein dediziertes Programm entwickelt das beim Hersteller angefordert und auf einen Computer installiert werden muss
Wir empfehlen die Software DVA USB Manager direkt von der Webseite dB Technologies (wwwdbtechnologiescom) im Abschnitt laquoSoftware amp Controllerraquo herunterzuladen
DVA Network
AC26N ist mit einer eigenen als RDNET bezeichneten Netzschnittstelle ausgestattet dank der es uumlber ein Interface (RDNET Control) an einen Computer angeschlossen werden koumlnnenHierzu wurde ein Kommunikationsprotokoll entwickelt mit dem die Daten empfangen und gesendet werden Dank dieser Verbindung koumlnnen die Lautsprecherparameter wie Ausgangsleistung Verstaumlrkertemperatur Limiterstatus usw in Echtzeit kontrolliert werden Auszligerdem koumlnnen verschiedene Entzerrungen ausgewaumlhlt bzw neue erstellt werden oder die gewuumlnschte Lautstaumlrke eingestellt werden
Wir empfehlen die Software DVA_Network direkt von der Webseite dB Technologies (wwwdbtechnologiescom) im Abschnitt laquoSoftware amp Controllerraquo herunterzuladenDOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
RUumlCKWANDANSCHLUumlSSE
1586 75 141210 11 13 169 17
14) USB-SteckverbinderDieser USB-Steckverbinder (Typ B) erlaubt den Prozessor an einem Computer anzuschlieszligen um die Firmware mit dem speziellen Programm (DVA Network) zu kontrollieren und zu aktualisieren
15) STROMANSCHLUSS MAINSErlaubt den Anschluss des mitgelieferten Versorgungskabels
16) SICHERUNGSTRAumlGER FUSEAufnahme fuumlr die Netz-Sicherung
17) HAUPTSCHALTER POWERDer Schalter erlaubt das Aus- und Einschalten des Audio-Controllers
BEDIENUNGEN UND FUNKTIONEN
5) WAHLSCHALTER -6dBDer Wahlschalter erlaubt das Level des analogen Eingangs XLR [6] um 6 dB zu verringern und gleichzeitig das hohe Ausgangslevel der Mixer oder anderer Audio-Vorrichtungen auszugleichen Wenn der Balken des Signallevels der Eingaumlnge auf dem Display [1] immer auf Maximum steht zeigt dies an dass das Signallevel am Eingang hoch ist und es wird empfohlen die Daumlmpfung -6dB zu benutzenIm Menuuml Option ist es moumlglich zu kontrollieren ob der Wahlschalter aktiviert ist
6) STECKVERBINDER AM EINGANG A UND BAuf Leitungslinie ausgeglichene EingaumlngeSie koumlnnen auch XLR-Steckdosen aufnehmen
7) AUSGANG-STECKVERBINDER ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo UND ldquo6rdquoAuf Leitungslinie ausgeglichene Ausgaumlnge Sie koumlnnen auch XLR-Stecker aufnehmen
Darauf achten dass die Ausgaumlnge korrekt entsprechend der Einstellungen der einzelnen Kanaumlle an den Lautsprechern oder Verstaumlrkern angeschlossen sind um Schaumlden und Fehlfunktionen vorzubeugen
Abschnitt ldquoAESEBUrdquo
8) EINGANGS-STECKVERBINDER INZusaumltzlich zu den analogen Audio-Eingaumlngen wurde ein digitaler Audio-Eingang SPDIF-AESEBU (AES3) vorgesehen der uumlber das Setup-Menuuml ausgewaumlhlt werden kannDer Eingang erfordert einen ausgeglichenen Anschluss mit einem XLR-Steckverbinder mit einem verdrillten Kabel mit 3 Leitern von 110 Ohm
9) AUSGANGS-STECKVERBINDER OUTDieser Steckverbinder erlaubt das Audiosignal an den analogen oder digitalen Eingaumlngen oder Ausgaumlngen zu verteilen Die Quelle muss uumlber das Menuuml Option eingestellt werdenDer Anschluss muss demselben Standard des Eingang entsprechen [Ref 8]
Abschnitt ldquoRDNETrdquo
10) EINGANGS-STECKVERBINDER DATA INPUTSteckverbinder RJ45 fuumlr den Dateneingang
11) AUSGANGS-STECKVERBINDER DATA LINKSteckverbinder RJ45 fuumlr den Datenausgang Fuumlr die serielle Kaskaden-Verbindung
12) LEUCHTANZEIGE ONDiese gruumlne Anzeige leuchtet nur wenn AC26N uumlber den Computer mit der Haupteinheit RDNET verbunden ist und diese erkannt hat
13) LEUCHTANZEIGE ACTIVEDiese gelbe Anzeige blinkt wenn eine Datenuumlbertragung zwischen RDNET und der Vorrichtung aktiv ist
PUSH
P SHU
SHPU
P SHU
PUSH
ANSCHLUumlSSE
Analoge Audio-AnschluumlsseDie ausgeglichenen Anschluumlsse erlauben die Geraumlusche der Kabel auf ein Minimum zu verringern und so die Benutzung langer Kabel zuzulassenDiese Anschluumlsse koumlnnen sowohl an den Ein- als auch an den Ausgaumlngen benutzt werdenDer XLR-Steckverbinder muss mit Pin 1 an Masse Pin 2 am Pluspol (+) und Pin 3 am Minuspol (-) angeschlossen werden Bei einem abgeschirmten Kabel muss die Abschirmung an Pin 1 liegenDie Verbindungskabel XLR-XLR und XLR-Jack 14 (63 mm) koumlnnen fuumlr den Anschluss
12
3
Eingang
XLR weiblichen
Pin 3 = MinuspolErkaumlltungphase -VE
Pin 3 = MinuspolErkaumlltungphase -VE
1 2
3
Ausgang
XLR maumlnnlichen
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Ring
Schaft
Spitze = PluspolWaumlrmephase +VE
Ring = MinuspolErkaumlltungphase -VE
Schaft=SchirmMasse
Spitze
Die nicht ausgeglichenen Anschluumlsse koumlnnen auch benutzt werden wenn die Kabelgeraumlusche ansteigen und diese Kabel duumlrfen nicht laumlnger sein als 5 MeterDiese Anschluumlsse koumlnnen sowohl an den Ein- als auch an den Ausgaumlngen benutzt werdenDie nicht ausgeglichenen Anschluumlsse koumlnnen das Signallevel am Eingang um 6 dB verringern um dem vorzubeugen muss Pin 3 an Masse angeschlossen werden obwohl dies das Geraumlusch verstaumlrken kann
12
3
Eingang
XLR weiblichen
1 2
3
Ausgang
XLR maumlnnlichen
Spitze Schaft
Spitze = Signal
Schaft=SchirmMasse
Pin 3 = zu Pin 1 gebruumlckt
Pin 3 = zu Pin 1 gebruumlckt
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
31
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
32
Digitales Audio (AESEBU)AESEBU (Protokoll AES3) ist ein ausgeglichener und uumlber einen Transformator elektrisch isolierter Eingang Er erlaubt die Benutzung von zwei Kanaumllen an einem einzigen abgeschirmten bipolaren Kabel Das gedrillte Kabel muss 3-polig sein eine Impedanz von 100 Ohm haben und mit einem XLR-Steckverbinder (AES3 Standard) abgeschirmt sein
RdnetJeder Port RDNet an Control 2 und Control 8 kann an max 32 kompatiblen Vorrichtungen die in Kaskade geschaltet sind angeschlossen werden Im nachstehenden Beispiel ist der Port der Kontrolleinheit RDNET CONTROL 2 am Eingang DATA INPUT eines AC 26N angeschlossen dessen paralleler Ausgang DATA LINK zum Eingang des naumlchsten AC26N geht Im Beispiel ist [n] eine Nummer zwischen 3 und 32 (maximale Anzahl der anschlieszligbaren Vorrichtungen an nur einem Netz)
RJ 45
|1|2|3|4|5|6|7|8|
Die Gesamtlaumlnge des Kabels CAT5 eines Unternetzes kann NICHT laumlnger als 900 Meter sein
Der Steckverbinder muss wie folgt angeschlossen sein1 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio +) 2 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio -)3 ndash Verfuumlgbar fuumlr andere Funktionen (zB analoge Masse)4 ndash digitale Masse5 ndash digitale Masse6 ndash Verfuumlgbar fuumlr andere Funktionen (zB Versorgung)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
EINSCHALTEN
Beim Einschalten der Vorrichtung startet die Initialisierung die einige Sekunden lang dauert Auf dem Display wird das Modell das Logo und der Fortschrittsbalken der Ladung des Programms angezeigt
Nach der Initialisierung erscheint auf dem Display das Menuumlfenster Meters Um die Angaben im Detail zu erfahren beziehen Sie sich bitte auf das Kapitel BESCHREIBUNG DES MENUumlFENSTERS Meters
AC26N kann jetzt benutzt werden
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
MENUrsquo PRINCIPALE
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Die sechs Menuumls im Prozessor zeigen undoder konfigurieren die Systemparameter
Anzeige der Levels der Ein- und Ausgaumlnge Anzeige des benutzten Programms und dessen Status Mute schnell
Speicherung Speicherung und Eliminierung der Systemkonfigurationen
Auswahl der Ausgaumlnge je nach Eingangssignal
Konfiguration jedes einzelnen Kanals
Konfiguration der Schnittfrequenzen und der Filtertypen fuumlr jeden einzelnen Ausgang
Zuordnung der Ein- und Ausgaumlnge Kontrast des Displays Firmware-Version Eingaumlnge und andere Optionen
Das Menuuml und die einzelnen Optionen der Anzeige koumlnnen durch Drehen des Drehgriffes FUNKTIONS SELECTOR ( ) ausgewaumlhlt werden
Die Hauptmenuumls sind
Meters
Preset
Matrix
Ch Job
X-Over
Option
Um die Auswahl zu treffen muss der gewuumlnschte Parameter auswaumlhlt und der Drehgriff Push Enter( | ) gedruumlckt werdenDas selbe Verfahren muss fuumlr die Auswahl undoder die Aumlnderung der Optionen innerhalb der Menuumlpunkte angewendet werden
BESCHREIBUNG DES MENUumlFENSTERS Meters
Diese Seite erlaubt die Konfigurationen und den allgemeinen Status der Ein- und Ausgaumlnge der benutzten Programmversion dessen Status und die Steuerung des Systems anzuzeigen
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
KONFIGURATION UND ANZEIGE
Um in das Fenster des Hauptmenuumls zu gelangen muss die Taste Menuuml ( ) auf der Frontseite der Vorrichtung gedruumlckt werdenMit der Taste ESC ( ) kehrt man von jeder Seite des Menuumls auf die vorherige Seite zuruumlck
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
33
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
34
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziertBei den digitalen Eingangssignalen entspricht die Angabe A und B dem EingangDreht man den Drehgriff FUNCTIONS SELECTOR [2] durchlaumluft man zyklisch die Ein- und Ausgangskanaumlle und die Angabe Mute allgemein (d) der ausgewaumlhlte Kanal wird hervorgehoben
b) BALKEN FUumlR DAS KOMPRESIONSLEVELMUTE KANAL
SIGNALKOMPRESSIONDie Signalkompression wird durch das Gleiten des rechten Balkens von oben nach unten angezeigt
MUTE Jeder einzelne Kanal kann auf Mute gestellt werden Den Kanal auswaumlhlen und den Drehgriff Push Enter [2] druumlcken um die Aumlnderung des Status zu bestaumltigen Die Angabe des Kanals wird durch den Buchstaben M ersetzt und der Balken wird komplett hervorgehobenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werden
c) BALKEN DES SIGNALLEVELSDie Anzeige des Levels jedes einzelnen Kanals wird durch das Gleiten des linken Balkens angezeigt
d) MUTE ALLGEMEINEs ist moumlglich alle Ein- und Ausgaumlnge gleichzeitig auf Mute zu schalten Den Drehgriff FUNCTIONS SELECTOR drehen den Buchstaben M waumlhlen und dann den Drehgriff Push Enter druumlckenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werdenDie allgemeine Stummschaltung hat eine houmlhere Prioritaumlt als die Stummschaltung der einzelnen Kanaumlle
e) ANSTEUERUNGSARTENEs wird angezeigt wie AC26N benutzt wird undoder an welchen Vorrichtungen es angeschlossen ist
= Benutzung stand-alone Kein Anschluss an einer externen Vorrichtung
= Direkt am Netz RDnet und am Computer angeschlossen
= Uumlber USB-Kabel direkt am Computer angeschlossen
f) ANZEIGE DES STATUS DER EINSTELLUNGENHier wird angezeigt ob einer oder mehrere Parameter des geladenen Programms im Vergleich zur letzten Speicherung veraumlndert wurden
Original-Programm
Programm mit veraumlnderten Parametern
g) EINGESTELLTES PROGRAMMDie Nummer zeigt das vom System geladene und benutzte Programm in Bezug auf die Lokalisierung der Speicherung an Fuumlr weitere Details beziehen Sie sich bitte auf das Menuuml Preset
Local
NET
USB
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
BESCHREIBUNG DES MENUumlFENSTERS Ch Job
Dieses Fenster erlaubt die Anzeige der Konfiguration jedes einzelnen Kanals
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) SIGNALLEVELZeigt die Signalstaumlrke an Das Ansteigen der Signalintensitaumlt wird in Dezibel (dB) ausgedruumlckt Der Parameter kann zwischen -8000 dB und +2000 dB in Schritten von 001 dB ausgewaumlhlt werden Ein Anstieg von 6 dB ist fast gleich eine Verdoppelung in linearer Skala des Spannungswertes des SignalsBei einer Staumlrke von 0 dB wird das Signal verstaumlrkt waumlhrend es ein einer Staumlrke von weniger als 0 dB abgeschwaumlcht wird
c) VERZOumlGERUNG DES SIGNALS (DELAY)Das wiedergegebene Audio-Signal kann verzoumlgert werden um die akustische Ausrichtung zu erlauben Dies gleicht die verschiedenen Positionen der Lautsprecher bei der Installation und Klangwiedergabe aus und wird in mS ausgedruumlckt Der Parameter kann zwischen 00 mS und 729 mS in Schritten von 01mS ausgewaumlhlt werden
Um ein Audiosignal auszurichten kann folgende Formel benutzt werden
Verzoumlgerung = GAPx1000)344
Verzoumlgerung = mS (in Millisekunden ausgedruumlckt)GAP = Abstand des Lautsprechers vom Referenzpunkt (in Metern ausgedruumlckt)Klanggeschwindigkeit = 344 ms
d) MUTEJeder einzelne Kanal kann auf Mute gestellt werden Derselbe Befehl kann im Fenster des Menuumls Meters aktiviert werden PS Die al lgemeine Stummschaltung hat eine houmlhere Priori taumlt als die Stummschaltung der einzelnen Kanaumlle
e) PHASEErlaubt die Phasenrotation um 180deg zum EingangssignalDiese Rotation erlaubt vor Allem die Optimierung der niederen Frequenzen bei komplexen Installationen
f) ENTZERRUNGENDieser Befehl oumlffnet das Menuumlfenster fuumlr die Entzerrung des einzelnen Kanals Er wird vor Allem benutzt um eine oder mehrere Frequenzen zu korrigieren die gedaumlmpft oder verstaumlrkt werden muumlssen
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
35
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
36
AC26N verwaltet 12 Filter fuumlr jeden einzelnen Ein- und Ausgangskanal mit drei verschiedenen Konfigurationen- Equalizer PEQ (peaking equalizer) ist ideal um nur ein bestimmtes Frequenzband
zu identifizieren zu isolieren und zu korrigieren Es gehen alle Frequenzen durch aber nur die um die mittlere Frequenz steigt und sinkt um eine bestimmte Bandbreite und eine bestimmte Staumlrke
- Equalizer High-Shelf geht alle Frequenzen durch aber die Frequenzen uumlber der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
- Equalizer Low-Shelf geht alle Frequenzen durch aber die Frequenzen unter der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
f Nummerierung der 12 verfuumlgbaren Filter fuumlr diesen Ein- oder Ausgang1
f2 Es wird der Filtertyp angezeigt
Dis Ausgeschaltet (nicht vorhanden)
PEQ Peaking equalizer
Sh H Filter High-Shelf
Sh L Filter Low-shelf
Beispiele PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
ANMERKUNGDer Parameter Bw legt das Frequenzfeld neben der eingestellten Frequenz fest wo der Filter aktiviert wird je houmlher der Bw-Wert desto houmlher das Frequenzfeld (1Bw=1 Oktave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filter High-Shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filter Low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) KOMPRESSIONDieser Befehl oumlffnet das Menuumlfenster fuumlr die Kompression des einzelnen Kanals
g1) TresholdIdentifiziert die Schwelle an der das Kompressionsverhaumlltnis beginnt Der Basiswert 11
g2) RatioIdentifiziert das Kompressionsverhaumlltnis zwischen dem Ein- und Ausgangssignal
g3) Post Gain Attach Release HoldDiese Daten entsprechen dem Kompressionsverhaumlltnis das man erreichen moumlchte
Post Gain ist der Gewinn am AusgangAttack ist die Anschlusszeit Release ist die ReleasezeitHold ist die Beibehaltungszeit
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
BESCHREIBUNG DES MENUumlFENSTERS Preset
Dieses Fenster erlaubt bis zu 32 Konfigurationen im AC26N zu speichernDer Hersteller liefert das System mit einem voreingestellten Programm das auf Position 0 gespeichert ist und nicht uumlberschrieben werden kann
032 Es zeigt die Lokalisierung der Speicherung der KonfigurationDiese Nummer erscheint auch im Fenster Meters auf der Position (g) Das benutzte Programm kann jederzeit vom Benutzer angezeigt werden
Empty Preset Es ist der Name der der Nummer der Lokalisierung zugeordnet wird wenn keine Einstellung gespeichert ist (leer)
Local preset Es i s t de r Name de r de r Nummer de r Loka l i s i e rung zugeordnet wird wenn eine Konfiguration gespeichert wird
ANMERKUNG = Man kann eine Einstellung mit dem gewuumlnschten Namen mit max 16 Buchstaben nur speichern wenn man die Schnittstelle uumlber den Computer benutzt
Bei der Wahl eines Programms erscheint folgendes Fenster
Anzeige des Namens der dem Programm zugeordnet istUm auf die Anwendung einzuwirken stehen 3 Auswahlmoumlglichkeiten zur Verfuumlgung
Das Programm wird im Speicher des AC 26N gespeichert
Das Programm wird geloumlscht
Das Programm wird geladen und ist bereit fuumlr die Benutzung
Save
Del
Load
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
37
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
38
BESCHREIBUNG DES MENUumlFENSTERS X-Over
Dieses Fenster erlaubt fuumlr jeden Ausgang einen Bassdurchgangsfilter einen Hochdurchgangsfilter oder mittels Kombination von beiden einen Banduumlbergangsfilter zu waumlhlenDer Filter ist ein Linkwitz-Riley wo man die Neigung von 12 dBoct 24dBoct oder 48 dBoct und die entsprechende Schnittfrequenz auswaumlhlen kann
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) AUSGANGSKANAumlLE
Die Steckverbinder am Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) FILTER CROSSOVERDen Filter nach Bedarf waumlhlen Man kann folgendes auswaumlhlen
Dis Kein Filter aktiviert
HP Hochdurchgangsfilter nur den Teil des Audiosignals durchlassen der uumlber der Schnittfrequenz liegt
LP Bassdurchgangsfilter nur den Teil des Audiosignals durchlassen der unter der Schnittfrequenz liegt
Filter-Konfiguration Tiefpass Hochpass
Nichts Dis Dis
Hochpass HP Dis
Tiefpass Dis LP
Bandpass HP LP
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
c) DAumlMPFUNGSNEIGUNGDie Daumlmpfungsneigung des Audiosignals auf der Basis der Verringerung auswaumlhlen die man erreichen moumlchte Je houmlher die Daumlmpfungsneigung bei gleicher Schnittfrequenz desto groumlszliger ist die Signalauswahl Man kann folgendes waumlhlen
12 entsprechend 12 dboct
24 entsprechend 24 dboct
48 entsprechend 48 dboct
d) SCHNITTFREQUENZErlaubt die Durchgangsfrequenz der niederen Frequenzen (Bassdurchgangsfilter) oder der hohen Frequenzen (Hochdruchgangsfilter) einzustellenDie Auswahl des Schnitts bezieht sich auf die Wiedergabe die man erreichen moumlchteDie benutzte Maszligeinheit ist Hz
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
BESCHREIBUNG DES MENUumlFENSTERS Matrix
Erlaubt fuumlr jeden Ausgang das Eingangssignal zu waumlhlen das als Quelle benutzt werden soll
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) AUSGANGSKANAumlLEIdentifizierung des einzustellenden Ausgangskanals
b) IDENTIFIZIERUNG DER EINGAumlNGEDen Signaltyp auswaumlhlen der nach eigener Anforderung jedem einzelnen Ausgang zugeordnet werden soll Man kann folgendes waumlhlen
In A Das Signal wird dem Eingang A zugeordnet
In B Das Signal wird dem Eingang B zugeordnet
In A+B Zuordnung der a lgebra ischen Summe der be iden Eingangssignale A und B
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
BESCHREIBUNG DES MENUumlFENSTERS Option
Erlaubt die Anzeige der Systemeinstellungen wie die Zuordnung der Ein- und Ausgaumlnge Daumlmpfung Displaykontrast und Firmware-Version
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B Src
Diese Option erlaubt die Einstellung des Audio-Signaltyps am Eingang
Analoge Audiosignale (Eingaumlnge A und B)
Digitale Audiosignale (Eingang AESEBU)
DigOut Src
An In =Audiosignale an den analogen Eingaumlngen
Dig In =Audiosignale am digitalen Eingang
OUT 1-2 =Audiosignale an den Ausgaumlngen 1 und 2
OUT 3-4 =Audiosignale an den Ausgaumlngen 3 und 4
OUT 5-6 =Audiosignale an den Ausgaumlngen 5 und 6
Input Mode
An In
Dig In
Indip =
Linked =
Diese Option erlaubt die Audioquelle zu waumlhlen die fuumlr den Steckverbinder AESEBU OUT (digitaler Ausgang) bestimmt ist
Erlaubt die Eingaumlnge zu konfigurieren
Sie sind unabhaumlngig und selbststaumlndig sie unterliegen keinen Verpflichtungen untereinander Sie sind verbunden und funktionieren im Stereo-Modus
Die Kompressoren Filter Verzoumlgerungen die Lautstaumlrke sind bei beiden Kanaumllen identisch
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
39
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
40
Atten PadZeigt an wie der Wahlschalter -6 dB auf der Ruumlckseite eingestellt ist [Ref 5] Dieser Wahlschalter muss aktiviert werden wenn das Level an den analogen Eingaumlngen zu hoch ist Der Wahlschalter wird uumlber die Taste aktiviert im Menuuml gibt es nur eine Anzeige
0dB = Wahlschalter nicht aktiviert
-6dB = Wahlschalter aktiviert
Contrast
10 heller 60 dunkler 100
Fw Vers
Die Eingangssignale sind dieselben wie die Eingangsquelle
Die Eingangssignale werden vom internen Prozessor um -6 dB gedaumlmpft
Erlaubt den Kontrast des LCD-Displays einzustellen um den Unterschied der Helligkeit auf den Installationsort auszurichten Ein deutlicheres Display erlaubt auf korrekte und schnelle Weise innerhalb der Menuumls zu surfenDie Hersteller-Einstellung am Ausgang liegt bei 60
Zeigt die Firmware-Version des Prozessors an
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
41
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
42
TECHNISCHE DATEN
Antwort in FrequenzDynamische GammaCMMRCrosstalkDistorsion
ProzessorFrequenz der DatenausarbeitungAnaloge Converter Verzoumlgerung der VerteilungSpeicherung der Konfigurationen
DisplayTastenBedienungen
Analoger Eingang ndeg2 x XLR (3-poliger Female Stecker)Impedanz des Eingangs gt10KOhmMaximales Level +21dBu ohne PAD
+27dBu bei PAD
Impedanz des Ausgangs 50OhmMaximales Level +21dBu Typ symmetrisch
Typ SPDIF-AESEBU (AES3)
Typ Entsprechend dem Standard des Eingang
Typ
Typ
NETZSPANNUNGABMESSUNGEN (BXHXT)GEWICHT
AUDIO-LEISTUNGEN+- 01dB (20 to 30kHz)116dB typgt 60dB (50 to 10kHz)lt -100dB0002 (1kHz +4dBu)
DIGITALE AUDIO-LEISTUNGEN DSP 2856-bit 48KHz24-bit BURR BROWN15ms32 preset
KONTROLLEN LCD GrafikESC - MENU - FUNCTIONS SELECTIONENTER
EIN-AUSGAumlNGE
Analoger Ausgang ndeg6 x XLR (3-poliger Male Stecker)
Digitaler Eingang ndeg1x XLR (3-poliger female Stecker)
Digitaler Ausgang ndeg1x XLR (3-poliger Male Stecker)
Ein-Ausgang Rdnet ndeg2 x XLR RJ45 (kabel CAT 5) USB Typ B
KONTROLLPARAMETER AUDIOStaumlrke -80dB a +20dB step 01dBVerzoumlgerung Eingang 0 a 729mS step 01 mS
Ausgang 0 a 340mS step 01mSPhasenrotation 0deg - 180deg
KOMPRESSIONSchwelle -80dB a +20dB step 01dBVerhaumlltnis 11 a Inf1 step 001Staumlrke am Ausgang 0dB a 40dB step 01dBAnschlusszeit 1mS a 1000mS step 01mSReleasezeit 1mS a 1000mS step 01mSBeibehaltungszeit 1mS a 1000mS step 01mS
EQUALIZER12 Equalizer fuumlr jeden Ein- und Ausgang
PEQ (parametrischer) Hi-shelf Lo-sheftFrequenz 20Hz a 20KHz step 1HzStaumlrke -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (lediglich PEQ)
FILTER CROSSOVERFilter Linkwitz Riley
HP HochdurchgangsfilterLP Bassdurchgangsfilter
Neigung 12dBoct - 24dBoct - 48dBoctSchnittfrequenz 5Hz a 20KHz step 1Hz
Full-range 100-240Vac 50-60Hz430482x43x130mm 19Kg
AnmerkungenSpezifikationen unterliegen Aumlnderungen ohne Vorankuumlndigung
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
INTRODUCTIONAC26N est un processeur audio numeacuterique pour la gestion de leacutequipement audio conccedilu pour des installations fixes et mobiles Il fonctionne selon une technologie de pointe avec des processeurs agrave 2856bits et des convertisseurs ADDA agrave 24-bits hautes performances Les fonctions du processeur sont les niveaux dentreacutee et de sortie le deacutelai (delay) la polariteacute 12 bandes deacutegalisation par canal dentreacutee et de sortie diffeacuterentes seacutelections de croisement (crossover) et un limiteur hautes performances Le controcircle des filtres a une reacutesolution de 1Hz Les entreacutees et les sorties peuvent ecirctre programmeacutees en plusieurs configurations pour satisfaire tous les besoins AC26N peut ecirctre controcircleacute en temps reacuteel et tous les paramegravetres peuvent ecirctre configureacutes depuis le pupitre frontale et par ordinateur avec interface graphique intuitive accessible via le logiciel laquoDVA Networkraquo et une connexion de reacuteseau deacutedieacutee RDnet ou USBLa mise agrave jour du logiciel pour lUniteacute centrale et DSP par ordinateur portable permet de maintenir le dispositif actualiseacute Il est possible denregistrer et de rappeler 32 configurations preacute-eacutequipeacutees de configuration
Contenu de lemballage - AC26N - Mode demploi- CD logiciel- Cacircble dalimentation
Caracteacuteristiques- 2 entreacutees et 6 sorties avec adressage flexible- Entreacutee et sortie steacutereacuteo AESEBU adressables - DSP 2856-bit- Convertisseurs AD BURR BWOWN 24-bit hautes performances- Freacutequence de reacutesolution des filtres 1 Hz - 12 eacutegaliseurs parameacutetriques pour chaque entreacutee et sortie- 2 filtres de croisement par sortie avec pente seacutelectionnable agrave 122448dBoct- DRC agrave configuration multiple hautes performances pour configuration limiteur
compression pour chaque entreacutee et sortie- Niveau reacuteglable en dB polariteacute et deacutelai pour chaque entreacutee et sortie- Mise agrave jour du micrologiciel par lordinateur- Affichage graphique agrave cristaux liquides- 32 preacutereacuteglages enregistrables par lutilisateur- Interface USB pour le controcircle et la configuration par ordinateur- Interface RDnet permettant de controcircler jusquagrave 256 dispositifs agrave distance
PC
PC
RDNETcontrol(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FONCTIONS DE LA FACE AVANT
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
COMMANDES ET FONCTIONS1) AFFICHAGE
Laffichage graphique agrave cristaux liquides permet de visualiser et deacutediter les informations de lAC26N sans utiliser lordinateur Le contraste peut ecirctre configureacute dans le menu principal
2) MANETTE Functions Selector et Push EnterCe controcircle permet de se deacuteplacer de seacutelectionner et de modifier les paramegravetres dans les menus affichables agrave leacutecranRotation de la manette (Functions Selectors)- permet de se deacuteplacer sur les diffeacuterentes pages du menu - permet de modifier les paramegravetres seacutelectionneacutesPression de la manette (Push Enter)- permet de seacutelectionnervalider les paramegravetres
3) Bouton ESC Ce controcircle permet de quitter les menus afficheacutes ou de revenir agrave la visualisation preacuteceacutedente
4) Bouton Menu Ce controcircle permet dacceacuteder directement au menu principal
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
Fra
nccedilais
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
43
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
Fra
nccedilais
44
DVA Network
AC26N est eacutequipeacute dune interface de reacuteseau proprieacutetaire deacutenommeacutee RDNET au moyen de laquelle il est possible de sinterfacer agrave lordinateur agrave travers un peacuteripheacuterique (RDNET control)
Pour cela un protocole de communication a eacuteteacute deacuteveloppeacute avec lequel il est possible de recevoir et denvoyer les donneacutees ce branchement permet de faire le monitorage en temps reacuteel des paramegravetres du diffuseur comme puissance de sortie tempeacuterature de lamplificateur eacutetat du limiteur etc Il est aussi possible de seacutelectionner diffeacuterentes eacutegalisations ou den creacuteer de nouvelles et de reacutegler les niveaux de volume souhaiteacutes au moyen dun plug-in approprieacute
On conseille de teacuteleacutecharger gratuitement le logiciel DVA Network directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
DVA USB Manager
On conseille de teacuteleacutecharger gratuitement le logiciel DVA USB Manager directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
Le micrologiciel du module amplificateur peut ecirctre remis agrave jour par le port USBPour rendre cette mise agrave jour possible et facile un programme speacutecifique a eacuteteacute deacuteveloppeacute
DOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
CONNEXIONS DU PANNEAU ARRIEgraveRE
1586 75 141210 11 13 169 17
14) Connecteur ldquo USBrdquoCe connecteur USB (type B) permet de connecter le processeur agrave un ordinateur pour le controcircle et la mise agrave jour du micrologiciel via un programme deacutedieacute (DVA Network)
15) PRISE DALIMENTATION MAINSPermet la connexion du cacircble dalimentation fourni de seacuterie
16) PORTE-FUSIBLE FUSELogement pour fusible de ligne
17) INTERRUPTEUR GENERAL POWERLinterrupteur permet de mettre en marche ou deacuteteindre le controcircleur audio
COMMANDES ET FONCTIONS
5) SELECTEUR ldquo-6dBrdquoLe seacutelecteur permet de reacuteduire de 6dB les niveaux dentreacutee analogiques XLR [6] tout en compensant les niveaux eacuteleveacutes de sortie des meacutelangeurs ou dautres dispositifs audio Quand la barre du niveau de signal des entreacutees sur laffichage [1] reste au maximum cela indique que le niveau du signal entrant est eacuteleveacute Il est alors conseilleacute dutiliser latteacutenuation -6dBIl est possible de veacuterifier quand le seacutelecteur est activeacute par le menu Option
6) CONNECTEURS DENTREE ldquoArdquo ET ldquoBrdquoEntreacutees eacutequilibreacutees au niveau de la ligneIls sont en mesure daccepter des connecteurs XLR macircles
7) CONNECTEURS DE SORTIE ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo ET ldquo6rdquoSorties eacutequilibreacutees au niveau de la ligne Ils sont en mesure daccepter des connecteurs XLR femelles
Prendre garde agrave brancher convenablement les sorties sur les diffuseurs ou les amplificateurs en fonction des configurations de chaque canal pour eacuteviter des deacutegacircts et des problegravemes de fonctionnement
Section ldquoAESEBUrdquo
8) CONNECTEUR DENTREE INOutre les entreacutees audio analogiques une entreacutee audio numeacuterique SPDIF-AESEBU (AES3) a eacuteteacute preacutevue et peut ecirctre seacutelectionneacutee par le menu de setupLentreacutee requiert une connexion eacutequilibreacutee en utilisant un connecteur XLR avec un cacircble agrave 3 conducteurs de 110ohm torsadeacute
9) CONNECTEUR DE SORTIE OUTCe connecteur permet de relancer le signal audio dans les entreacutees analogiques ou numeacuteriques ou sur les sorties La source doit ecirctre reacutegleacutee par le menu OptionLa connexion sera conforme agrave la mecircme norme que lentreacutee [reacutef8]
Section ldquoRDNETrdquo
10) CONNECTEUR DENTREE DATA INPUTConnecteur RJ45 entreacutee de donneacutees
11) CONNECTEUR DE SORTIE DATA LINKConnecteur RJ45 sortie de donneacutees pour la connexion de seacuterie en cascade
12) VOYANT LUMINEUX ONCe voyant de couleur verte sallume uniquement quand lAC26N a reconnu et est connecteacute agrave luniteacute principale RDNET par lordinateur
13) VOYANT LUMINEUX ACTIVECe voyant de couleur jaune clignote quand une transmission des donneacutees est active entre RDNET et le dispositif
PUSH
P SHU
SHPU
P SHU
PUSH
CONNEXIONS
Audio analogiquesLes connexions eacutequilibreacutees permettent de reacuteduire au minimum le bruit provoqueacute par les cacircbles et dutiliser de longs cacircblesCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLe connecteur XLR doit ecirctre brancheacute avec la broche 1 agrave la masse la broche 2 au chaud (+) et la broche 3 au froid (-) En cas de cacircble blindeacute brancher le blindage agrave la broche 1Les cacircbles de connexion XLR-XLR et XLR-Jack14(63mm) peuvent semployer pour la connexion agrave lAC26N
12
3
Entreacutee
Entreacutee
XLR - femme
XLR - femme
1 2
3
Sortie
Sortie
XLR - Macircle
XLR - Macircle
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2 = Point chaudPhase +VE
Broche 3 =Point froidPhase -VE
Broche 3 =Point froidPhase -VE
Anneau
Manchon
Pointe Point chaudPhase +VE
Anneau = Point froidPhase -VE
ManchonB Masselindeacute
Pointe
Les connexions deacuteseacutequilibreacutees peuvent semployer mecircme si le bruit provoqueacute par les cacircbles augmente Les cacircbles ne peuvent deacutepasser 5m de longCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLes connexions deacuteseacutequilibreacutees peuvent abaisser le niveau du signal entrant de 6dB Pour remeacutedier agrave cet inconveacutenient il faut brancher la broche 3 agrave la masse mecircme si cela augmente le bruit
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
45
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
46
12
3
1 2
3
Pointe Manchon
Pointe = Signal
Broche 3 = Link to Pin 1
Broche 3 = Link to Pin 1
ManchonB Masselindeacute
Audio numeacuteriques (AESEBU)
AESEBU (protocole AES3) est une entreacutee eacutequilibreacutee isoleacutee eacutelectriquement agrave laide dun transformateur Elle permet demployer deux canaux audio dans un seul cacircble bipolaire blindeacute Les caracteacuteristiques du cacircble doivent ecirctre de 3 pocircles impeacutedance 100ohm torsadeacute et blindeacute avec connecteur XLR (AES3 standard)
RJ 45
|1|2|3|4|5|6|7|8|
RDnet
Chaque port RDNet des Control 2 et Control 8 peut ecirctre brancheacute agrave un maximum de 32 dispositifs compatibles placeacutes en cascade Dans lexemple suivant le port de luniteacute de controcircle RDNET CONTROL 2 est relieacute agrave lentreacutee DATA INPUT dun AC26N dont la sortie parallegravele DATA LINK est envoyeacutee agrave lentreacutee de lAC26N successif Dans lexemple [n] est un nombre compris entre 3 et 32 (limite maximale des dispositifs que lon peut relier agrave un sous-reacuteseau)
La longueur totale du cacircble CAT5 dun sous-reacuteseau NE peut PAS deacutepasser 900 megravetres
Le connecteur doit ecirctre relieacute comme 1 ndash disponible pour dautres fonctions (par exemple audio +) 2 ndash disponible pour dautres fonctions (par exemple audio )3 ndash disponible pour dautres fonctions (par exemple masse analogique)4 ndash masse numeacuterique5 ndash masse numeacuterique6 ndash disponible pour dautres fonctions (par exemple alimentation)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
MISE EN MARCHE
Lors de la mise en marche du dispositif linitialisation deacutebute et dure quelques secondes Leacutecran affiche le modegravele le logo et la barre de progression du chargement du programme
En fin de processus dinstallation leacutecran affiche la fenecirctre du menu Meters Pour connaicirctre les indications en deacutetail consulter le paragraphe DESCRIPTION FENETRE MENU Meters
LAC26N est precirct agrave lemploi
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION ET VISUALISATION
Pour entrer dans la fenecirctre du menu principal il faut pousser sur la touche MENU ( ) agrave lavant du dispositifDune page quelconque du menu en poussant sur la touche ESCrdquo ( ) on revient automatiquement sur la page-eacutecran preacuteceacutedente
MENU PRINCIPAL
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Le processeur contient six menus Ils montrent etou configurent les paramegravetres du systegravemeLes menus principaux sont
Meters Visualisation des niveaux des entreacutees et des sorties visualisation du programme utiliseacute et eacutetat mute rapide
Preset Meacutemoriser enregistrer et eacuteliminer les configurations du systegraveme
Matrix seacutelectionner les sorties en fonction du signal entrant
Ch Job configuration de chaque signal
X-Over configurer les freacutequences de coupure et les types de filtres pour chaque sortie
Option attribution des entreacutees et des sorties contraste daffichage la version du micrologiciel les entreacutees et dautres options
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
47
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
48
DESCRIPTION DE LA FENETRE MENU Metersrdquo
Cette fenecirctre permet de visualiser les configurations et leacutetat geacuteneacuteral des entreacutees et des sorties la version du programme utiliseacute son eacutetat et le mode de pilotage du systegraveme
Les menus et les options afficheacutees peuvent se seacutelectionner en tournant la manette ldquoFUNCTIONS SETECTORrdquo ( ) Pour avoir accegraves agrave linteacuterieur de la seacutelection il faut mettre le paramegravetre souhaiteacute en eacutevidence et pousser sur la manette ldquoPush Enterrdquo ( | ) Il faut en faire de mecircme pour seacutelectionner etou modifier les options dans les commandes du menu
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositifAvec des signaux dentreacutee numeacuteriques les indications ldquoArdquo et ldquoBrdquo correspondent agrave lentreacuteeEn tournant la manette ldquoFUNCTIONS SELECTORrdquo [2] on fait deacutefiler en mode cyclique les canaux dentreacutee de sortie et lindication de mute geacuteneacuteral (d) le canal seacutelectionneacute est mis en eacutevidence
b) BARRE DE NIVEAU DE COMPRESSIONMUTE CANAL
COMPRESSION DE SIGNALLa compression du signal est visualiseacutee par le deacutefilement de la barre de droite de haut en bas
MUTE Chaque canal peut ecirctre placeacute en mute Seacutelectionner le canal et pousser sur la manette ldquoPush Enterrdquo [2] pour valider le changement deacutetat Lindication du canal sera remplaceacutee par la lettre M et la barre sera totalement mise en eacutevidencePour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterations
c) BARRE DE NIVEAU DE SIGNALLindication du niveau de chaque canal est signaleacutee par le deacutefilement de la barre de gauche
d) MUTE GENERALIl est possible de mettre simultaneacutement toutes les entreacutees et les sorties en mute Tourner la manette ldquoFUNCTIONS SELECTORrdquo seacutelectionner la lettre M et pousser sur la manette Push EnterPour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterationsLe mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) MODES DE COMMANDEIl affiche le mode dutilisation etou les dispositifs qui sont relieacutes agrave lAC26N
Local = utilisation autonome Aucune connexion agrave un dispositif exteacuterieur
NET = relieacute directement au reacuteseau deacutedieacute RDNet et agrave lordinateur
USB = relieacute directement agrave un ordinateur par cacircble USB
f) INDICATION DETAT DE PARAMETRAGECette indication permet de constater si un ou plusieurs paramegravetre(s) du programme chargeacute aont eacuteteacute modifieacute(s) par rapport au dernier sauvetage
= programme dorigine
= programme avec des paramegravetres modifieacutes
g) PROGRAMME CONFIGURELe chiffre indique le programme chargeacute et utiliseacute par le systegraveme agrave lemplacement de sauvetage Consulter le menu de Preset pour de plus amples deacutetails
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
DESCRIPTION DE LA FENETRE MENU Ch Job
Cette fenecirctre permet dafficher la configuration de chaque canal
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) NIVEAU DU SIGNALIndique le gain du signal Laugmentation de lintensiteacute dun signal est libelleacutee en deacutecibel (dB) Le paramegravetre peut ecirctre seacutelectionneacute de -8000dB agrave +2000dB avec des pas de 001dB Une augmentation de 6dB est eacutegale approximativement au redoublement agrave leacutechelle lineacuteaire du niveau du signal sous tensionAvec un gain supeacuterieur agrave 0dB le signal est amplifieacute tandis quavec un gain infeacuterieur agrave 0dB le signal est atteacutenueacute
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
49
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
50
c) DELAI DU SIGNAL (DELAY)Le signal audio reproduit peut ecirctre retardeacute pour permettre lalignement acoustique Cela compense les diffeacuterentes positions des diffuseurs pendant linstallation et la reproduction sonore Il se libelle en mS Le paramegravetre peut ecirctre seacutelectionneacute de 00mS agrave 729mS avec un pas de 01mSPour aligner un signal audio il est possible dutiliser la formule suivante
Deacutelai = (GAPx1000)344
Deacutelai = ms (en millisecondes)GAP = distance du diffuseur du point de reacutefeacuterence (en megravetres)Vitesse du son = 344ms
d) MUTEChaque canal peut ecirctre placeacute en mute La mecircme commande peut ecirctre activeacutee dans la fenecirctre du menu meters NB Le mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) PhasePermet la rotation de phase de 180deg par rapport au signal entrantCette rotation permet loptimisation surtout des basses freacutequences dans les installations complexes
f) EGALISATIONCette commande ouvre la fenecirctre du menu deacutegalisation de chaque canal Elle sert surtout pour corriger une ou plusieurs freacutequences qui doivent ecirctre atteacutenueacutees ou augmenteacutees
M M
LAC26N gegravere 12 filtres par canal dentreacutee et sortie avec trois types de configurations diffeacuterentes - Leacutegaliseur PEQ (peaking equalizer) est ideacuteal pour identifier isoler et
corriger une seule plage de freacutequences bien deacutetermineacutee Toutes les freacutequences passent mais il augmente ou diminue uniquement celles autour de la freacutequence centrale pour une bande preacutecise et un gain deacutefini
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessus de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessous de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
f Numeacuterotation des 12 filtres disponibles pour cette entreacutee ou cette sortie1
f Le type de filtre est afficheacute 2
Dis Deacutesactiveacute (absent)
PEQ Peaking equlizer
Sh H Filtre high-shelf
Sh L Filtre high-shelf
Exemples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
REMARQUELe paramegravetre Bw deacutetermine le champ de freacutequences adjacent agrave la freacutequence configureacutee ougrave est activeacute le filtre Plus la valeur Bw est eacuteleveacutee plus vaste est le champ de freacutequences (1Bw=1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONCette commande ouvre la fenecirctre du menu de compression de chaque canal
g1) TresholdIdentifie le seuil ougrave commence le rapport de compression La valeur de base 11
g2) RatioIndique le rapport de conversion entre le signal entrant et le signal sortant
g3) Post Gain Attach Release HoldCes donneacutees deacutependent du rapport de conversion que lon veut obtenir - Post Gain est le gain de sortie- Attack est le temps dattaque - Release est le temps de relacircchement- Hold est le temps de maintien
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
52
DESCRIPTION DE LA FENETRE MENU Preset
Cette fenecirctre permet de meacutemoriser jusquagrave 32 configurations dans lAC26NLe fabricant fournit le systegraveme avec un programme configureacute et enregistreacute en position 0 et non susceptible deacutecrasement
032 Elle indique lemplacement de sauvetage de la configurationCe numeacutero apparaicirct dans la fenecirctre Meters en position (g) A tout moment le programme utiliseacute peut ecirctre afficheacute par lutilisateur
Empty Preset Cest le nom qui est associeacute au numeacutero de lemplacement quand aucune configuration (vide) nest enregistreacutee
Local preset Local preset est le nom qui est associeacute au numeacutero de lemplacement quand on enregistre une configuration NB = Il est possible denregistrer une configuration avec lenom souhaiteacute de 16 lettres tout au plus agrave condition que lonutilise linterface via lordinateur
Le nom du programme assigneacute est indiqueacutePour toucher agrave lapplication 3 choix soffrent agrave vous
Save Le programme est enregistreacute en meacutemoire de lAC26N
Del Le programme est effaceacute
Load Le programme est chargeacute et precirct agrave lemploi
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
51
DESCRIPTION DE LA FENETRE MENU X-Over
Cette fenecirctre permet de seacutelectionner un filtre passe bas un filtre passe haut ou par la combinaison des deux de creacuteer un filtre passe bande pour chaque sortieLe filtre actif est un Linkwitz-Riley qui permet de seacutelectionner la pente de 12dBoct 24dBoct ou 48dBoct et sa freacutequence de coupure
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) CANAUX DE SORTIE
Les connecteurs de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) FILTRE CROSSOVERSeacutelectionner le filtre selon les besoins Il est possible de seacutelectionner
Dis Aucun filtre activeacute
HP Filtre passe-haut laisse passer uniquement la partie de signal audio supeacuterieure agrave la freacutequence de coupure
LP Filtre passe-bas laisse passer uniquement la partie de signal audio infeacuterieure agrave la freacutequence de coupure
Configuration du filtre Passe-haut Passe-bas
Rien Dis Dis
Passe-haut HP Dis
Passe-bas Dis LP
Passe-bande HP LP
12dBoct
24dBoct
Hz
dB
Ga
in 48dBoct
12dBoct
24dBoct
Hz
dB
Ga
in
48dBoct
c) PENTE DATTENUATIONSeacutelectionner la pente datteacutenuation du signal audio en fonction de la diminution que lon veut obtenir Plus la pente datteacutenuation est eacuteleveacutee agrave eacutegaliteacute de freacutequence de coupure plus eacuteleveacutee sera la seacutelection du signal Il est possible de seacutelectionner
12 correspond agrave 12dboct
24 correspond agrave 24dboct
48 correspond agrave 48dboct
d) FREQUENCE DE COUPUREElle permet de reacutegler la freacutequence de passage des freacutequences infeacuterieures (filtre passe-bas) ou des freacutequences supeacuterieures (filtre passe-haut) uniquementLe choix de la coupure deacutepend de la reproduction que lon veut obtenirLuniteacute de mesure utiliseacutee est lHz
Hz
Hz
dB
dB
Ga
in
f0
f0
0dB0dB
0dB
-6dB
freacutequence
freacutequence
freacutequence
freacutequence
Ga
in
f0
0dB
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
53
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
54
DESCRIPTION DE LA FENETRE MENU Matrix
Elle permet de seacutelectionner le signal entrant agrave utiliser comme source pour chaque sortie
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) CANAUX DE SORTIEIdentification du canal sortant agrave reacutegler
b) IDENTIFICATIONS DES ENTREESSeacutelectionner le type de signal agrave associer agrave chaque sortie en fonction des besoins Il est possible de seacutelectionner
In A Le signal entrant A est associeacute
In B Le signal entrant B est associeacute
In A+B La somme algeacutebrique des deux signaux entrants A et B est associeacutee
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
DESCRIPTION DE LA FENETRE MENU Option
Permet dafficher les reacuteglages du systegraveme comme lassignation des entreacutees et des sorties latteacutenuation le contraste de laffichage et la version du logiciel
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcCette option permet de reacutegler le type de signal audio entrant
An In =signaux audio analogiques (entreacutees ldquoArdquo et ldquoBrdquo)
Dig In =signaux audio numeacuteriques (entreacutee AESEBU)
DigOut SrcCette option permet de seacutelectionner la source audio qui sera adresseacutee sur le connecteur AESEBU OUT (sortie numeacuterique)
An In = signaux audio des entreacutees analogiques
Dig In =signaux audio sur lentreacutee numeacuterique
OUT 1-2 = signaux audio sur les sorties 1 et 2
OUT 3-4 = signaux audio sur les sorties 3 et 4
OUT 5-6 = signaux audio sur les sorties 5 et 6
Input ModePermet de configurer les entreacutees
Indip = sont indeacutependantes et autonomes Ne sont soumises agrave aucun type de lien
Linked = sont unies et fonctionnent en mode steacutereacuteo Les compresseurs les filtres les deacutelais le volume sont identiques pour les deux canaux
Atten PadIndique le mode de reacuteglage du seacutelecteur ldquo-6dBrdquo placeacute agrave larriegravere [reacutef 5] Il faut activer ce seacutelecteur quand les niveaux dentreacutee analogiques sont trop eacuteleveacutes Le seacutelecteur sactive uniquement par le bouton Dans le menu il sagit dune simple visualisation
0dB = seacutelecteur non activeacute Les signaux dentreacutee sont identiques agrave la source entrante
-6dB = seacutelecteur activeacute Les signaux entrants sont atteacutenueacutes de -6dB par le processeur interne
ContrastIl permet de reacutegler le contraste de laffichage agrave cristaux liquides pour compenser la diffeacuterence de luminositeacute avec le lieu dinstallation Une plus grande clarteacute de laffichage permet de naviguer convenablement et rapidement dans les menusLe reacuteglage agrave la sortie de lusine du fabricant est de 60
10 plus clair 60 plus fonceacute 100
Fw VersIndique la version du logiciel du processeur
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
55
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
56
DONNES TECHINIQUES
PERFORMANCES AUDIOReacuteponse en freacutequence +- 01dB (20 to 30kHz)Plage dynamique 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsion 0002 (1kHz +4dBu)
PERFORMANCES AUDIO NUMERIQUES Processeur DSP 2856-bit Freacutequence de traitement des donneacutees 48KHzConvertisseurs analogiques 24-bit BURR BROWNDeacutelai de propagation 15msMeacutemorisations des configurations 32 preset
CONTROLES Affichage LCD graficoBoutonsCommandes ESC - MENU - FUNCTIONS SELECTION
ENTERENTREESSORTIESEntreacutee analogique ndeg2 x XLR (3 broches femelle)
Impeacutedance dentreacutee gt10KOhmNiveau maximum +21dBu senza PAD
+27dBu con PADSortie analogique ndeg6 x XLR (3 broches macircle )
Impeacutedance de sortie 50OhmNiveau maximum +21dBuType Balanceacute
Entreacutee numeacuterique ndeg1x XLR (3 broches femelle)Type SPDIF-AESEBU (AES3)
Sortie numeacuterique ndeg1x XLR (3 broches macircle )Type conforme agrave la norme de lentreacutee
EntreacuteesSortie Rdnet ndeg2 x XLR RJ45 (cacircble CAT 5)USB Type B
PARAMETRES DE CONTROLE DU SONGain -80dB a +20dB eacutetape 01dBDeacutelai Entreacutee 0 a 729mS eacutetape 01 mS
Sortie 0 a 340mS eacutetape 01mSRotation de phase 0deg - 180deg
COMPRESSIONSeuil -80dB a +20dB eacutetape 01dBRapport 11 a Inf1 eacutetape 001Gain agrave la sortie 0dB a 40dB eacutetape 01dBTemps dattaque 1mS a 1000mS eacutetape 01mSTemps de relacircchement 1mS a 1000mS eacutetape 01mSTemps de maintien 1mS a 1000mS eacutetape 01mS
EGALISEURS12 eacutegaliseurs pour chaque entreacutee et sortieType PEQ (parameacutetrique) Hi-shelf Lo-sheft
Freacutequence 20Hz a 20KHz eacutetape 1HzGain -30dB a +15dB eacutetape 001dBBande 005dB a 2dB eacutetape 001dB (uniquement pour PEQ)
FILTRES CROSSOVERFiltre Linkwitz Riley
Type HF high-shelfLF low-shelf
Pente 12dBoct - 24dBoct - 48dBoctFreacutequence de coupure 5Hz a 20KHz eacutetape 1Hz
ALIMENTATION Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)POIDS 19Kg
Remarques Speacutecifications sujettes agrave modifications sans preacuteavis
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
2 VIE ATTIVO2 WAY ACTIVE
3 VIE PASSIVO3 WAY PASSIVE
L
L
A
A
HIGH L
MID L
LOW HIGHMID RHIGHMID L
LOW L
HIGH R
MID R
LOW R
R
R
B
B
1
1
2
2
3
3
456
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
Menu Matrix configurationMatrix
57 58
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
EROUIG ATRIX TNM
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
OU
TP
UT
1
OU
TP
UT
2
OU
TP
UT
3
OU
TP
UT
4
OU
TP
UT
5
OU
TP
UT
6
AE
S-E
BU
OU
TP
UT
INP
UT
A
AE
S-E
BU
INP
UT
INP
UT
B
D D D D D D
D D
A A A A A A
A SA
MP
LE
RA
TE
CO
NV
A
LIN
KA
BL
E
SC
HE
MA
A B
LO
CC
HI -
BL
OC
K D
IAG
RA
MB
LO
CK
SC
HA
LT
BIL
D -
SC
HE
MA
S F
ON
CT
ION
NE
LS
LINE ARRAY SUB MONO ATTIVO
LINE ARRAY SUB MONO ACTIVEINGRESSI - INPUT
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
L
L
L
A
A
A
AESEBU IN
AESEBU IN
AESEBU IN
AESEBU OUT
AESEBU IN
AESEBU IN
AESEBU OUT
R
R
R
LR
B
B
B
123456
HIGHMID L
HIGHMID L HIGHMID R
HIGHMID R
LOW L LOW R
LAYER
DISPLAY MEMORY
FADER MODE
LAYER
DISPLAY MEMORY
FADER MODE
Ingresso ANALOGICO
ANALOG Input
Collegamento in cascata
Link connections
Ingresso DIGITALE
DIGITAL inputA B
BALANCED AUDIO INPUTS
-6dB
PUSH PUSH
IN OUT
AES EBUPUSH
Oppure
or
Oppure
or
Menu Option configurationOption
Menu Option configurationOption Menu Option configurationOption
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type Analog
AES out An In
Input type Analog
AES out An In
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
59 60
InA-B Src Dig InInA-B Src Dig InInA-B Src An InInA-B Src An In
frequenzaHz
dB
Gu
ad
ag
no
60 200 2800
0dB0dB
-6dB
Esempio di un sistema a 3-vie
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
Out 1 Out 2 Out 3
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Esempio di un sistema a 3-vie
61 62
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
26NAC 26NAC
R TE
DO
R
MO LEU O R CE S
E O TR L A
S O
O C ND I P
P hsuernE t
o su cti nF nel rS e tc o
E CSME UN
IGCHTE OL SN EOBd
ocaL l
M
0
484
467
430
44
31
75
12
7
DIMENSIONI DIMENSIONSABMESSUNGEN DIMENSIONS
Atten PadIt shows how to set the -6 dB switch located on the rear side [Ref 5] It is necessary to activate this selector when the analog input levels are too high The selector can be activated only by means of the button the menu is for display only
0 dB = Selector not activated The input signals are the same as the input source
-6 dB = Selector activated The input signals are attenuated by -6 dB with reference to the inner
processor
ContrastAllows to adjust the LCD display contrast to compensate for the brightness difference at the installation sites Greater display brightness allows to navigate correctly and quickly within the menuThe manufacturer output setting is 60
10 More bright 60 More dark 100
Fw VersIt shows the processor firmware version
En
glis
hE
ng
lish
En
glis
hu
se
r m
an
ua
lu
se
r m
an
ua
l
28
us
er
ma
nu
al
us
er
ma
nu
al
En
glis
hE
ng
lish
En
glis
h
27
TECHINICAL SPECIFICATION
AUDIO PERFORMANCEFrequency Response +- 01dB (20 to 30kHz)Dynamic Range 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistortion 0002 (1kHz +4dBu)
DIGITAL AUDIO PERFORMANCE Processor DSP 2856-bit Data processing Frequency 24-bit BURR BROWNAnalog converters 24-bit BURR BROWNPropagation Delay 15msStoring configurations 32 preset
CONTROLS Display LCD graficoButtonsControls ESC - MENU - FUNCTIONS SELECTION
ENTERINPUTSOUTPUTSAnalog Input ndeg2 x XLR (3 pole female)
Input impedance gt10KOhmMaximum Level +21dBu senza PAD
+27dBu con PADAnalog Output ndeg6 x XLR (3 pole male)
Output impedance 50OhmMaximum Level +21dBu Type Balanced
Digital Input ndeg1x XLR (3 pole female)Type SPDIF-AESEBU (AES3)
Digital Output ndeg1x XLR (3 pole male)Type Compliant with the input standard
RDnet InputsOutput ndeg2 x XLR RJ45 (CAT 5 cable)USB Tipo B
SOUND CONTROL PARAMETERSGain -80dB a +20dB step 01dBDelay
Input 0 a 729mS step 01 mSOutput 0 a 340mS step 01mSPhase Rotation 0deg - 180deg
COMPRESSIONThreshold -80dB a +20dB step 01dBRatio 11 a Inf1 step 001Output gain 0dB a 40dB step 01dBAttack time 1mS a 1000mS step 01mSRelease time 1mS a 1000mS step 01mSHold time 1mS a 1000mS step 01mS
EQUALIZERS12 equalizers for each input and outputType PEQ (parametrico) Hi-shelf Lo-sheft
Frequency 20Hz a 20KHz step 1HzGain -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (only with PEQ)
CROSSOVER FILTERSFilter Linkwitz Riley
Type HP High-pass LP Low-pass
Slope 12dBoct - 24dBoct - 48dBoctCUT-OFF FREQUENCY 5Hz a 20KHz passo 1Hz
POWER SUPPLY Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)
1719x17x51 inch (WxHxD)WEIGHT 19Kg
(42 lbs)Note Specifications subject to change without notice
EMI CLASSIFICATIONAccording to the standards EN 55103 this equipment is designed and suitable to operate in E3 (or lower E2 E1) Electromagnetic environments
EINLEITUNG
Verpackungsinhalt
Eigenschaften
AC26N ist ein digitaler Audio-Prozessor fuumlr die Verwaltung von Audio-Systemen der fuumlr feste und mobile Installationen entwickelt wurde AC26N benutzt die modernste Technologie mit 2856 bit-Prozessoren und 24-bit-ADDA-Wandlern mit hoher Leistungsfaumlhigkeit Die verfuumlgbaren Funktionen des Prozessors sind Ein- und Ausgangsstufen Verzoumlgerung (delay) Polaritaumlt 12 Equalizer-Frequenzen fuumlr Ein- und Ausgangskanal viele Crossover-Wahlmoumlglichkeiten und Limiter mit hoher Leistung Die Filter-Kontrolle hat eine Aufloumlsung von 1 Hz Die Ein- und Ausgaumlnge koumlnnen mit unterschiedlichen Einstellungen geregelt werden um allen Anforderungen gerecht zu werden AC26N kann in Echtzeit kontrolliert werden und jeder Parameter kann am Frontpaneel und vom Computer mit intuitiver graphischer Schnittstelle mittels Software DVA Network zugaumlnglich und einer Netzverbindung RDnet oder uumlber USB eingestellt werdenDie SW-Aktualisierung fuumlr CPU und DSP uumlber PC erlaubt die Vorrichtung auf dem aktuellen Stand zu halten Man kann 32 vorgesehene Konfigurationen speichern und aufrufen
- AC26N - Bedienungsanleitung- Software-CD- Versorgungskabel
- 2 Ein- und 6 Ausgaumlnge mit flexibler Adressierung- Adressierbarer Stereo-Ein- und Ausgang AESEBU - DSP 2856-bit- AD-Wandler BURR BROWN 24-bit mit hoher Leistungsfaumlhigkeit- Aufloumlsungsfrequenz der Filter 1 Hz - 12 parametrische Equalizer fuumlr jeden Ein- und Ausgang- 2 Crossover-Filter fuumlr jeden Ausgang mit auswaumlhlbarer Neigung 122448dBoct- DRC Multikonfiguration mit hoher Leistungsfaumlhigkeit fuumlr die Konfiguration des
Limitersder Kompression jedes Ein- und Ausgangs- Einstellbare dB-Stufe Polaritaumlt und Verzoumlgerung (delay) fuumlr jeden Ein- und Ausgang- Firmware-Aktualisierung uumlber PC- Graphisches LCD-Display- 32 Voreinstellungen vom Benutzer einstellbar- USB-Schnittstelle fuumlr die Kontrolle und Konfiguration mit dem Computer- Schnittstelle RDnet welche erlaubt bis zu 256 fern liegende Vorrichtungen
zu kontrollieren
PC
PC
RDNET control(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FUNKTIONEN VORDERSEITE
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
BEDIENUNGEN UND FUNKTIONEN
1) DISPLAYDas graphische LCD-Display erlaubt die Informationen des AC26N ohne einen Computer zu benutzen anzuzeigen und zu editieren Der Kontrast kann im Hauptmenuuml eingestellt werden
2) DREHGRIFF Functions Selector UND Push EnterDiese Kontrolle erlaubt sich in den Menuumls auf dem Display zu bewegen und die Parameter auszuwaumlhlen und zu veraumlndernDrehung des Drehgriffes (Functions Selectors)- Man kann sich innerhalb der verschiedenen Menuumlseiten bewegen- Erlaubt die Veraumlnderung der ausgewaumlhlten ParameterDruck des Drehgriffes (Push Enter)- Erlaubt die AuswahlBestaumltigung der Parameter
3) Taste ldquoESCrdquo Diese Kontrolle erlaubt die angezeigten Menuumls zu verlassen oder zur vorherigen Anzeige zuruumlckzukehren
4) Taste ldquoMenuumlrdquo Diese Kontrolle erlaubt den direkten Zugang zum Hauptmenuuml
Deuts
chD
euts
chB
ed
ien
un
gsan
leit
un
gB
ed
ien
un
gsan
leit
un
g
29
Deuts
chD
euts
chB
ed
ien
un
gsan
leit
un
gB
ed
ien
un
gsan
leit
un
g
30
DVA USB Manager
Die Firmware des Verstaumlrkermoduls kann uumlber den USB-Anschluss aktualisiert werdenUm diesen Vorgang zu ermoumlglichen und zu vereinfachen wurde ein dediziertes Programm entwickelt das beim Hersteller angefordert und auf einen Computer installiert werden muss
Wir empfehlen die Software DVA USB Manager direkt von der Webseite dB Technologies (wwwdbtechnologiescom) im Abschnitt laquoSoftware amp Controllerraquo herunterzuladen
DVA Network
AC26N ist mit einer eigenen als RDNET bezeichneten Netzschnittstelle ausgestattet dank der es uumlber ein Interface (RDNET Control) an einen Computer angeschlossen werden koumlnnenHierzu wurde ein Kommunikationsprotokoll entwickelt mit dem die Daten empfangen und gesendet werden Dank dieser Verbindung koumlnnen die Lautsprecherparameter wie Ausgangsleistung Verstaumlrkertemperatur Limiterstatus usw in Echtzeit kontrolliert werden Auszligerdem koumlnnen verschiedene Entzerrungen ausgewaumlhlt bzw neue erstellt werden oder die gewuumlnschte Lautstaumlrke eingestellt werden
Wir empfehlen die Software DVA_Network direkt von der Webseite dB Technologies (wwwdbtechnologiescom) im Abschnitt laquoSoftware amp Controllerraquo herunterzuladenDOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
RUumlCKWANDANSCHLUumlSSE
1586 75 141210 11 13 169 17
14) USB-SteckverbinderDieser USB-Steckverbinder (Typ B) erlaubt den Prozessor an einem Computer anzuschlieszligen um die Firmware mit dem speziellen Programm (DVA Network) zu kontrollieren und zu aktualisieren
15) STROMANSCHLUSS MAINSErlaubt den Anschluss des mitgelieferten Versorgungskabels
16) SICHERUNGSTRAumlGER FUSEAufnahme fuumlr die Netz-Sicherung
17) HAUPTSCHALTER POWERDer Schalter erlaubt das Aus- und Einschalten des Audio-Controllers
BEDIENUNGEN UND FUNKTIONEN
5) WAHLSCHALTER -6dBDer Wahlschalter erlaubt das Level des analogen Eingangs XLR [6] um 6 dB zu verringern und gleichzeitig das hohe Ausgangslevel der Mixer oder anderer Audio-Vorrichtungen auszugleichen Wenn der Balken des Signallevels der Eingaumlnge auf dem Display [1] immer auf Maximum steht zeigt dies an dass das Signallevel am Eingang hoch ist und es wird empfohlen die Daumlmpfung -6dB zu benutzenIm Menuuml Option ist es moumlglich zu kontrollieren ob der Wahlschalter aktiviert ist
6) STECKVERBINDER AM EINGANG A UND BAuf Leitungslinie ausgeglichene EingaumlngeSie koumlnnen auch XLR-Steckdosen aufnehmen
7) AUSGANG-STECKVERBINDER ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo UND ldquo6rdquoAuf Leitungslinie ausgeglichene Ausgaumlnge Sie koumlnnen auch XLR-Stecker aufnehmen
Darauf achten dass die Ausgaumlnge korrekt entsprechend der Einstellungen der einzelnen Kanaumlle an den Lautsprechern oder Verstaumlrkern angeschlossen sind um Schaumlden und Fehlfunktionen vorzubeugen
Abschnitt ldquoAESEBUrdquo
8) EINGANGS-STECKVERBINDER INZusaumltzlich zu den analogen Audio-Eingaumlngen wurde ein digitaler Audio-Eingang SPDIF-AESEBU (AES3) vorgesehen der uumlber das Setup-Menuuml ausgewaumlhlt werden kannDer Eingang erfordert einen ausgeglichenen Anschluss mit einem XLR-Steckverbinder mit einem verdrillten Kabel mit 3 Leitern von 110 Ohm
9) AUSGANGS-STECKVERBINDER OUTDieser Steckverbinder erlaubt das Audiosignal an den analogen oder digitalen Eingaumlngen oder Ausgaumlngen zu verteilen Die Quelle muss uumlber das Menuuml Option eingestellt werdenDer Anschluss muss demselben Standard des Eingang entsprechen [Ref 8]
Abschnitt ldquoRDNETrdquo
10) EINGANGS-STECKVERBINDER DATA INPUTSteckverbinder RJ45 fuumlr den Dateneingang
11) AUSGANGS-STECKVERBINDER DATA LINKSteckverbinder RJ45 fuumlr den Datenausgang Fuumlr die serielle Kaskaden-Verbindung
12) LEUCHTANZEIGE ONDiese gruumlne Anzeige leuchtet nur wenn AC26N uumlber den Computer mit der Haupteinheit RDNET verbunden ist und diese erkannt hat
13) LEUCHTANZEIGE ACTIVEDiese gelbe Anzeige blinkt wenn eine Datenuumlbertragung zwischen RDNET und der Vorrichtung aktiv ist
PUSH
P SHU
SHPU
P SHU
PUSH
ANSCHLUumlSSE
Analoge Audio-AnschluumlsseDie ausgeglichenen Anschluumlsse erlauben die Geraumlusche der Kabel auf ein Minimum zu verringern und so die Benutzung langer Kabel zuzulassenDiese Anschluumlsse koumlnnen sowohl an den Ein- als auch an den Ausgaumlngen benutzt werdenDer XLR-Steckverbinder muss mit Pin 1 an Masse Pin 2 am Pluspol (+) und Pin 3 am Minuspol (-) angeschlossen werden Bei einem abgeschirmten Kabel muss die Abschirmung an Pin 1 liegenDie Verbindungskabel XLR-XLR und XLR-Jack 14 (63 mm) koumlnnen fuumlr den Anschluss
12
3
Eingang
XLR weiblichen
Pin 3 = MinuspolErkaumlltungphase -VE
Pin 3 = MinuspolErkaumlltungphase -VE
1 2
3
Ausgang
XLR maumlnnlichen
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Ring
Schaft
Spitze = PluspolWaumlrmephase +VE
Ring = MinuspolErkaumlltungphase -VE
Schaft=SchirmMasse
Spitze
Die nicht ausgeglichenen Anschluumlsse koumlnnen auch benutzt werden wenn die Kabelgeraumlusche ansteigen und diese Kabel duumlrfen nicht laumlnger sein als 5 MeterDiese Anschluumlsse koumlnnen sowohl an den Ein- als auch an den Ausgaumlngen benutzt werdenDie nicht ausgeglichenen Anschluumlsse koumlnnen das Signallevel am Eingang um 6 dB verringern um dem vorzubeugen muss Pin 3 an Masse angeschlossen werden obwohl dies das Geraumlusch verstaumlrken kann
12
3
Eingang
XLR weiblichen
1 2
3
Ausgang
XLR maumlnnlichen
Spitze Schaft
Spitze = Signal
Schaft=SchirmMasse
Pin 3 = zu Pin 1 gebruumlckt
Pin 3 = zu Pin 1 gebruumlckt
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
31
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
32
Digitales Audio (AESEBU)AESEBU (Protokoll AES3) ist ein ausgeglichener und uumlber einen Transformator elektrisch isolierter Eingang Er erlaubt die Benutzung von zwei Kanaumllen an einem einzigen abgeschirmten bipolaren Kabel Das gedrillte Kabel muss 3-polig sein eine Impedanz von 100 Ohm haben und mit einem XLR-Steckverbinder (AES3 Standard) abgeschirmt sein
RdnetJeder Port RDNet an Control 2 und Control 8 kann an max 32 kompatiblen Vorrichtungen die in Kaskade geschaltet sind angeschlossen werden Im nachstehenden Beispiel ist der Port der Kontrolleinheit RDNET CONTROL 2 am Eingang DATA INPUT eines AC 26N angeschlossen dessen paralleler Ausgang DATA LINK zum Eingang des naumlchsten AC26N geht Im Beispiel ist [n] eine Nummer zwischen 3 und 32 (maximale Anzahl der anschlieszligbaren Vorrichtungen an nur einem Netz)
RJ 45
|1|2|3|4|5|6|7|8|
Die Gesamtlaumlnge des Kabels CAT5 eines Unternetzes kann NICHT laumlnger als 900 Meter sein
Der Steckverbinder muss wie folgt angeschlossen sein1 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio +) 2 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio -)3 ndash Verfuumlgbar fuumlr andere Funktionen (zB analoge Masse)4 ndash digitale Masse5 ndash digitale Masse6 ndash Verfuumlgbar fuumlr andere Funktionen (zB Versorgung)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
EINSCHALTEN
Beim Einschalten der Vorrichtung startet die Initialisierung die einige Sekunden lang dauert Auf dem Display wird das Modell das Logo und der Fortschrittsbalken der Ladung des Programms angezeigt
Nach der Initialisierung erscheint auf dem Display das Menuumlfenster Meters Um die Angaben im Detail zu erfahren beziehen Sie sich bitte auf das Kapitel BESCHREIBUNG DES MENUumlFENSTERS Meters
AC26N kann jetzt benutzt werden
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
MENUrsquo PRINCIPALE
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Die sechs Menuumls im Prozessor zeigen undoder konfigurieren die Systemparameter
Anzeige der Levels der Ein- und Ausgaumlnge Anzeige des benutzten Programms und dessen Status Mute schnell
Speicherung Speicherung und Eliminierung der Systemkonfigurationen
Auswahl der Ausgaumlnge je nach Eingangssignal
Konfiguration jedes einzelnen Kanals
Konfiguration der Schnittfrequenzen und der Filtertypen fuumlr jeden einzelnen Ausgang
Zuordnung der Ein- und Ausgaumlnge Kontrast des Displays Firmware-Version Eingaumlnge und andere Optionen
Das Menuuml und die einzelnen Optionen der Anzeige koumlnnen durch Drehen des Drehgriffes FUNKTIONS SELECTOR ( ) ausgewaumlhlt werden
Die Hauptmenuumls sind
Meters
Preset
Matrix
Ch Job
X-Over
Option
Um die Auswahl zu treffen muss der gewuumlnschte Parameter auswaumlhlt und der Drehgriff Push Enter( | ) gedruumlckt werdenDas selbe Verfahren muss fuumlr die Auswahl undoder die Aumlnderung der Optionen innerhalb der Menuumlpunkte angewendet werden
BESCHREIBUNG DES MENUumlFENSTERS Meters
Diese Seite erlaubt die Konfigurationen und den allgemeinen Status der Ein- und Ausgaumlnge der benutzten Programmversion dessen Status und die Steuerung des Systems anzuzeigen
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
KONFIGURATION UND ANZEIGE
Um in das Fenster des Hauptmenuumls zu gelangen muss die Taste Menuuml ( ) auf der Frontseite der Vorrichtung gedruumlckt werdenMit der Taste ESC ( ) kehrt man von jeder Seite des Menuumls auf die vorherige Seite zuruumlck
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
33
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
34
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziertBei den digitalen Eingangssignalen entspricht die Angabe A und B dem EingangDreht man den Drehgriff FUNCTIONS SELECTOR [2] durchlaumluft man zyklisch die Ein- und Ausgangskanaumlle und die Angabe Mute allgemein (d) der ausgewaumlhlte Kanal wird hervorgehoben
b) BALKEN FUumlR DAS KOMPRESIONSLEVELMUTE KANAL
SIGNALKOMPRESSIONDie Signalkompression wird durch das Gleiten des rechten Balkens von oben nach unten angezeigt
MUTE Jeder einzelne Kanal kann auf Mute gestellt werden Den Kanal auswaumlhlen und den Drehgriff Push Enter [2] druumlcken um die Aumlnderung des Status zu bestaumltigen Die Angabe des Kanals wird durch den Buchstaben M ersetzt und der Balken wird komplett hervorgehobenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werden
c) BALKEN DES SIGNALLEVELSDie Anzeige des Levels jedes einzelnen Kanals wird durch das Gleiten des linken Balkens angezeigt
d) MUTE ALLGEMEINEs ist moumlglich alle Ein- und Ausgaumlnge gleichzeitig auf Mute zu schalten Den Drehgriff FUNCTIONS SELECTOR drehen den Buchstaben M waumlhlen und dann den Drehgriff Push Enter druumlckenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werdenDie allgemeine Stummschaltung hat eine houmlhere Prioritaumlt als die Stummschaltung der einzelnen Kanaumlle
e) ANSTEUERUNGSARTENEs wird angezeigt wie AC26N benutzt wird undoder an welchen Vorrichtungen es angeschlossen ist
= Benutzung stand-alone Kein Anschluss an einer externen Vorrichtung
= Direkt am Netz RDnet und am Computer angeschlossen
= Uumlber USB-Kabel direkt am Computer angeschlossen
f) ANZEIGE DES STATUS DER EINSTELLUNGENHier wird angezeigt ob einer oder mehrere Parameter des geladenen Programms im Vergleich zur letzten Speicherung veraumlndert wurden
Original-Programm
Programm mit veraumlnderten Parametern
g) EINGESTELLTES PROGRAMMDie Nummer zeigt das vom System geladene und benutzte Programm in Bezug auf die Lokalisierung der Speicherung an Fuumlr weitere Details beziehen Sie sich bitte auf das Menuuml Preset
Local
NET
USB
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
BESCHREIBUNG DES MENUumlFENSTERS Ch Job
Dieses Fenster erlaubt die Anzeige der Konfiguration jedes einzelnen Kanals
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) SIGNALLEVELZeigt die Signalstaumlrke an Das Ansteigen der Signalintensitaumlt wird in Dezibel (dB) ausgedruumlckt Der Parameter kann zwischen -8000 dB und +2000 dB in Schritten von 001 dB ausgewaumlhlt werden Ein Anstieg von 6 dB ist fast gleich eine Verdoppelung in linearer Skala des Spannungswertes des SignalsBei einer Staumlrke von 0 dB wird das Signal verstaumlrkt waumlhrend es ein einer Staumlrke von weniger als 0 dB abgeschwaumlcht wird
c) VERZOumlGERUNG DES SIGNALS (DELAY)Das wiedergegebene Audio-Signal kann verzoumlgert werden um die akustische Ausrichtung zu erlauben Dies gleicht die verschiedenen Positionen der Lautsprecher bei der Installation und Klangwiedergabe aus und wird in mS ausgedruumlckt Der Parameter kann zwischen 00 mS und 729 mS in Schritten von 01mS ausgewaumlhlt werden
Um ein Audiosignal auszurichten kann folgende Formel benutzt werden
Verzoumlgerung = GAPx1000)344
Verzoumlgerung = mS (in Millisekunden ausgedruumlckt)GAP = Abstand des Lautsprechers vom Referenzpunkt (in Metern ausgedruumlckt)Klanggeschwindigkeit = 344 ms
d) MUTEJeder einzelne Kanal kann auf Mute gestellt werden Derselbe Befehl kann im Fenster des Menuumls Meters aktiviert werden PS Die al lgemeine Stummschaltung hat eine houmlhere Priori taumlt als die Stummschaltung der einzelnen Kanaumlle
e) PHASEErlaubt die Phasenrotation um 180deg zum EingangssignalDiese Rotation erlaubt vor Allem die Optimierung der niederen Frequenzen bei komplexen Installationen
f) ENTZERRUNGENDieser Befehl oumlffnet das Menuumlfenster fuumlr die Entzerrung des einzelnen Kanals Er wird vor Allem benutzt um eine oder mehrere Frequenzen zu korrigieren die gedaumlmpft oder verstaumlrkt werden muumlssen
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
35
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
36
AC26N verwaltet 12 Filter fuumlr jeden einzelnen Ein- und Ausgangskanal mit drei verschiedenen Konfigurationen- Equalizer PEQ (peaking equalizer) ist ideal um nur ein bestimmtes Frequenzband
zu identifizieren zu isolieren und zu korrigieren Es gehen alle Frequenzen durch aber nur die um die mittlere Frequenz steigt und sinkt um eine bestimmte Bandbreite und eine bestimmte Staumlrke
- Equalizer High-Shelf geht alle Frequenzen durch aber die Frequenzen uumlber der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
- Equalizer Low-Shelf geht alle Frequenzen durch aber die Frequenzen unter der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
f Nummerierung der 12 verfuumlgbaren Filter fuumlr diesen Ein- oder Ausgang1
f2 Es wird der Filtertyp angezeigt
Dis Ausgeschaltet (nicht vorhanden)
PEQ Peaking equalizer
Sh H Filter High-Shelf
Sh L Filter Low-shelf
Beispiele PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
ANMERKUNGDer Parameter Bw legt das Frequenzfeld neben der eingestellten Frequenz fest wo der Filter aktiviert wird je houmlher der Bw-Wert desto houmlher das Frequenzfeld (1Bw=1 Oktave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filter High-Shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filter Low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) KOMPRESSIONDieser Befehl oumlffnet das Menuumlfenster fuumlr die Kompression des einzelnen Kanals
g1) TresholdIdentifiziert die Schwelle an der das Kompressionsverhaumlltnis beginnt Der Basiswert 11
g2) RatioIdentifiziert das Kompressionsverhaumlltnis zwischen dem Ein- und Ausgangssignal
g3) Post Gain Attach Release HoldDiese Daten entsprechen dem Kompressionsverhaumlltnis das man erreichen moumlchte
Post Gain ist der Gewinn am AusgangAttack ist die Anschlusszeit Release ist die ReleasezeitHold ist die Beibehaltungszeit
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
BESCHREIBUNG DES MENUumlFENSTERS Preset
Dieses Fenster erlaubt bis zu 32 Konfigurationen im AC26N zu speichernDer Hersteller liefert das System mit einem voreingestellten Programm das auf Position 0 gespeichert ist und nicht uumlberschrieben werden kann
032 Es zeigt die Lokalisierung der Speicherung der KonfigurationDiese Nummer erscheint auch im Fenster Meters auf der Position (g) Das benutzte Programm kann jederzeit vom Benutzer angezeigt werden
Empty Preset Es ist der Name der der Nummer der Lokalisierung zugeordnet wird wenn keine Einstellung gespeichert ist (leer)
Local preset Es i s t de r Name de r de r Nummer de r Loka l i s i e rung zugeordnet wird wenn eine Konfiguration gespeichert wird
ANMERKUNG = Man kann eine Einstellung mit dem gewuumlnschten Namen mit max 16 Buchstaben nur speichern wenn man die Schnittstelle uumlber den Computer benutzt
Bei der Wahl eines Programms erscheint folgendes Fenster
Anzeige des Namens der dem Programm zugeordnet istUm auf die Anwendung einzuwirken stehen 3 Auswahlmoumlglichkeiten zur Verfuumlgung
Das Programm wird im Speicher des AC 26N gespeichert
Das Programm wird geloumlscht
Das Programm wird geladen und ist bereit fuumlr die Benutzung
Save
Del
Load
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
37
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
38
BESCHREIBUNG DES MENUumlFENSTERS X-Over
Dieses Fenster erlaubt fuumlr jeden Ausgang einen Bassdurchgangsfilter einen Hochdurchgangsfilter oder mittels Kombination von beiden einen Banduumlbergangsfilter zu waumlhlenDer Filter ist ein Linkwitz-Riley wo man die Neigung von 12 dBoct 24dBoct oder 48 dBoct und die entsprechende Schnittfrequenz auswaumlhlen kann
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) AUSGANGSKANAumlLE
Die Steckverbinder am Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) FILTER CROSSOVERDen Filter nach Bedarf waumlhlen Man kann folgendes auswaumlhlen
Dis Kein Filter aktiviert
HP Hochdurchgangsfilter nur den Teil des Audiosignals durchlassen der uumlber der Schnittfrequenz liegt
LP Bassdurchgangsfilter nur den Teil des Audiosignals durchlassen der unter der Schnittfrequenz liegt
Filter-Konfiguration Tiefpass Hochpass
Nichts Dis Dis
Hochpass HP Dis
Tiefpass Dis LP
Bandpass HP LP
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
c) DAumlMPFUNGSNEIGUNGDie Daumlmpfungsneigung des Audiosignals auf der Basis der Verringerung auswaumlhlen die man erreichen moumlchte Je houmlher die Daumlmpfungsneigung bei gleicher Schnittfrequenz desto groumlszliger ist die Signalauswahl Man kann folgendes waumlhlen
12 entsprechend 12 dboct
24 entsprechend 24 dboct
48 entsprechend 48 dboct
d) SCHNITTFREQUENZErlaubt die Durchgangsfrequenz der niederen Frequenzen (Bassdurchgangsfilter) oder der hohen Frequenzen (Hochdruchgangsfilter) einzustellenDie Auswahl des Schnitts bezieht sich auf die Wiedergabe die man erreichen moumlchteDie benutzte Maszligeinheit ist Hz
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
BESCHREIBUNG DES MENUumlFENSTERS Matrix
Erlaubt fuumlr jeden Ausgang das Eingangssignal zu waumlhlen das als Quelle benutzt werden soll
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) AUSGANGSKANAumlLEIdentifizierung des einzustellenden Ausgangskanals
b) IDENTIFIZIERUNG DER EINGAumlNGEDen Signaltyp auswaumlhlen der nach eigener Anforderung jedem einzelnen Ausgang zugeordnet werden soll Man kann folgendes waumlhlen
In A Das Signal wird dem Eingang A zugeordnet
In B Das Signal wird dem Eingang B zugeordnet
In A+B Zuordnung der a lgebra ischen Summe der be iden Eingangssignale A und B
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
BESCHREIBUNG DES MENUumlFENSTERS Option
Erlaubt die Anzeige der Systemeinstellungen wie die Zuordnung der Ein- und Ausgaumlnge Daumlmpfung Displaykontrast und Firmware-Version
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B Src
Diese Option erlaubt die Einstellung des Audio-Signaltyps am Eingang
Analoge Audiosignale (Eingaumlnge A und B)
Digitale Audiosignale (Eingang AESEBU)
DigOut Src
An In =Audiosignale an den analogen Eingaumlngen
Dig In =Audiosignale am digitalen Eingang
OUT 1-2 =Audiosignale an den Ausgaumlngen 1 und 2
OUT 3-4 =Audiosignale an den Ausgaumlngen 3 und 4
OUT 5-6 =Audiosignale an den Ausgaumlngen 5 und 6
Input Mode
An In
Dig In
Indip =
Linked =
Diese Option erlaubt die Audioquelle zu waumlhlen die fuumlr den Steckverbinder AESEBU OUT (digitaler Ausgang) bestimmt ist
Erlaubt die Eingaumlnge zu konfigurieren
Sie sind unabhaumlngig und selbststaumlndig sie unterliegen keinen Verpflichtungen untereinander Sie sind verbunden und funktionieren im Stereo-Modus
Die Kompressoren Filter Verzoumlgerungen die Lautstaumlrke sind bei beiden Kanaumllen identisch
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
39
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
40
Atten PadZeigt an wie der Wahlschalter -6 dB auf der Ruumlckseite eingestellt ist [Ref 5] Dieser Wahlschalter muss aktiviert werden wenn das Level an den analogen Eingaumlngen zu hoch ist Der Wahlschalter wird uumlber die Taste aktiviert im Menuuml gibt es nur eine Anzeige
0dB = Wahlschalter nicht aktiviert
-6dB = Wahlschalter aktiviert
Contrast
10 heller 60 dunkler 100
Fw Vers
Die Eingangssignale sind dieselben wie die Eingangsquelle
Die Eingangssignale werden vom internen Prozessor um -6 dB gedaumlmpft
Erlaubt den Kontrast des LCD-Displays einzustellen um den Unterschied der Helligkeit auf den Installationsort auszurichten Ein deutlicheres Display erlaubt auf korrekte und schnelle Weise innerhalb der Menuumls zu surfenDie Hersteller-Einstellung am Ausgang liegt bei 60
Zeigt die Firmware-Version des Prozessors an
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
41
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
42
TECHNISCHE DATEN
Antwort in FrequenzDynamische GammaCMMRCrosstalkDistorsion
ProzessorFrequenz der DatenausarbeitungAnaloge Converter Verzoumlgerung der VerteilungSpeicherung der Konfigurationen
DisplayTastenBedienungen
Analoger Eingang ndeg2 x XLR (3-poliger Female Stecker)Impedanz des Eingangs gt10KOhmMaximales Level +21dBu ohne PAD
+27dBu bei PAD
Impedanz des Ausgangs 50OhmMaximales Level +21dBu Typ symmetrisch
Typ SPDIF-AESEBU (AES3)
Typ Entsprechend dem Standard des Eingang
Typ
Typ
NETZSPANNUNGABMESSUNGEN (BXHXT)GEWICHT
AUDIO-LEISTUNGEN+- 01dB (20 to 30kHz)116dB typgt 60dB (50 to 10kHz)lt -100dB0002 (1kHz +4dBu)
DIGITALE AUDIO-LEISTUNGEN DSP 2856-bit 48KHz24-bit BURR BROWN15ms32 preset
KONTROLLEN LCD GrafikESC - MENU - FUNCTIONS SELECTIONENTER
EIN-AUSGAumlNGE
Analoger Ausgang ndeg6 x XLR (3-poliger Male Stecker)
Digitaler Eingang ndeg1x XLR (3-poliger female Stecker)
Digitaler Ausgang ndeg1x XLR (3-poliger Male Stecker)
Ein-Ausgang Rdnet ndeg2 x XLR RJ45 (kabel CAT 5) USB Typ B
KONTROLLPARAMETER AUDIOStaumlrke -80dB a +20dB step 01dBVerzoumlgerung Eingang 0 a 729mS step 01 mS
Ausgang 0 a 340mS step 01mSPhasenrotation 0deg - 180deg
KOMPRESSIONSchwelle -80dB a +20dB step 01dBVerhaumlltnis 11 a Inf1 step 001Staumlrke am Ausgang 0dB a 40dB step 01dBAnschlusszeit 1mS a 1000mS step 01mSReleasezeit 1mS a 1000mS step 01mSBeibehaltungszeit 1mS a 1000mS step 01mS
EQUALIZER12 Equalizer fuumlr jeden Ein- und Ausgang
PEQ (parametrischer) Hi-shelf Lo-sheftFrequenz 20Hz a 20KHz step 1HzStaumlrke -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (lediglich PEQ)
FILTER CROSSOVERFilter Linkwitz Riley
HP HochdurchgangsfilterLP Bassdurchgangsfilter
Neigung 12dBoct - 24dBoct - 48dBoctSchnittfrequenz 5Hz a 20KHz step 1Hz
Full-range 100-240Vac 50-60Hz430482x43x130mm 19Kg
AnmerkungenSpezifikationen unterliegen Aumlnderungen ohne Vorankuumlndigung
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
INTRODUCTIONAC26N est un processeur audio numeacuterique pour la gestion de leacutequipement audio conccedilu pour des installations fixes et mobiles Il fonctionne selon une technologie de pointe avec des processeurs agrave 2856bits et des convertisseurs ADDA agrave 24-bits hautes performances Les fonctions du processeur sont les niveaux dentreacutee et de sortie le deacutelai (delay) la polariteacute 12 bandes deacutegalisation par canal dentreacutee et de sortie diffeacuterentes seacutelections de croisement (crossover) et un limiteur hautes performances Le controcircle des filtres a une reacutesolution de 1Hz Les entreacutees et les sorties peuvent ecirctre programmeacutees en plusieurs configurations pour satisfaire tous les besoins AC26N peut ecirctre controcircleacute en temps reacuteel et tous les paramegravetres peuvent ecirctre configureacutes depuis le pupitre frontale et par ordinateur avec interface graphique intuitive accessible via le logiciel laquoDVA Networkraquo et une connexion de reacuteseau deacutedieacutee RDnet ou USBLa mise agrave jour du logiciel pour lUniteacute centrale et DSP par ordinateur portable permet de maintenir le dispositif actualiseacute Il est possible denregistrer et de rappeler 32 configurations preacute-eacutequipeacutees de configuration
Contenu de lemballage - AC26N - Mode demploi- CD logiciel- Cacircble dalimentation
Caracteacuteristiques- 2 entreacutees et 6 sorties avec adressage flexible- Entreacutee et sortie steacutereacuteo AESEBU adressables - DSP 2856-bit- Convertisseurs AD BURR BWOWN 24-bit hautes performances- Freacutequence de reacutesolution des filtres 1 Hz - 12 eacutegaliseurs parameacutetriques pour chaque entreacutee et sortie- 2 filtres de croisement par sortie avec pente seacutelectionnable agrave 122448dBoct- DRC agrave configuration multiple hautes performances pour configuration limiteur
compression pour chaque entreacutee et sortie- Niveau reacuteglable en dB polariteacute et deacutelai pour chaque entreacutee et sortie- Mise agrave jour du micrologiciel par lordinateur- Affichage graphique agrave cristaux liquides- 32 preacutereacuteglages enregistrables par lutilisateur- Interface USB pour le controcircle et la configuration par ordinateur- Interface RDnet permettant de controcircler jusquagrave 256 dispositifs agrave distance
PC
PC
RDNETcontrol(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FONCTIONS DE LA FACE AVANT
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
COMMANDES ET FONCTIONS1) AFFICHAGE
Laffichage graphique agrave cristaux liquides permet de visualiser et deacutediter les informations de lAC26N sans utiliser lordinateur Le contraste peut ecirctre configureacute dans le menu principal
2) MANETTE Functions Selector et Push EnterCe controcircle permet de se deacuteplacer de seacutelectionner et de modifier les paramegravetres dans les menus affichables agrave leacutecranRotation de la manette (Functions Selectors)- permet de se deacuteplacer sur les diffeacuterentes pages du menu - permet de modifier les paramegravetres seacutelectionneacutesPression de la manette (Push Enter)- permet de seacutelectionnervalider les paramegravetres
3) Bouton ESC Ce controcircle permet de quitter les menus afficheacutes ou de revenir agrave la visualisation preacuteceacutedente
4) Bouton Menu Ce controcircle permet dacceacuteder directement au menu principal
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
Fra
nccedilais
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
43
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
Fra
nccedilais
44
DVA Network
AC26N est eacutequipeacute dune interface de reacuteseau proprieacutetaire deacutenommeacutee RDNET au moyen de laquelle il est possible de sinterfacer agrave lordinateur agrave travers un peacuteripheacuterique (RDNET control)
Pour cela un protocole de communication a eacuteteacute deacuteveloppeacute avec lequel il est possible de recevoir et denvoyer les donneacutees ce branchement permet de faire le monitorage en temps reacuteel des paramegravetres du diffuseur comme puissance de sortie tempeacuterature de lamplificateur eacutetat du limiteur etc Il est aussi possible de seacutelectionner diffeacuterentes eacutegalisations ou den creacuteer de nouvelles et de reacutegler les niveaux de volume souhaiteacutes au moyen dun plug-in approprieacute
On conseille de teacuteleacutecharger gratuitement le logiciel DVA Network directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
DVA USB Manager
On conseille de teacuteleacutecharger gratuitement le logiciel DVA USB Manager directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
Le micrologiciel du module amplificateur peut ecirctre remis agrave jour par le port USBPour rendre cette mise agrave jour possible et facile un programme speacutecifique a eacuteteacute deacuteveloppeacute
DOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
CONNEXIONS DU PANNEAU ARRIEgraveRE
1586 75 141210 11 13 169 17
14) Connecteur ldquo USBrdquoCe connecteur USB (type B) permet de connecter le processeur agrave un ordinateur pour le controcircle et la mise agrave jour du micrologiciel via un programme deacutedieacute (DVA Network)
15) PRISE DALIMENTATION MAINSPermet la connexion du cacircble dalimentation fourni de seacuterie
16) PORTE-FUSIBLE FUSELogement pour fusible de ligne
17) INTERRUPTEUR GENERAL POWERLinterrupteur permet de mettre en marche ou deacuteteindre le controcircleur audio
COMMANDES ET FONCTIONS
5) SELECTEUR ldquo-6dBrdquoLe seacutelecteur permet de reacuteduire de 6dB les niveaux dentreacutee analogiques XLR [6] tout en compensant les niveaux eacuteleveacutes de sortie des meacutelangeurs ou dautres dispositifs audio Quand la barre du niveau de signal des entreacutees sur laffichage [1] reste au maximum cela indique que le niveau du signal entrant est eacuteleveacute Il est alors conseilleacute dutiliser latteacutenuation -6dBIl est possible de veacuterifier quand le seacutelecteur est activeacute par le menu Option
6) CONNECTEURS DENTREE ldquoArdquo ET ldquoBrdquoEntreacutees eacutequilibreacutees au niveau de la ligneIls sont en mesure daccepter des connecteurs XLR macircles
7) CONNECTEURS DE SORTIE ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo ET ldquo6rdquoSorties eacutequilibreacutees au niveau de la ligne Ils sont en mesure daccepter des connecteurs XLR femelles
Prendre garde agrave brancher convenablement les sorties sur les diffuseurs ou les amplificateurs en fonction des configurations de chaque canal pour eacuteviter des deacutegacircts et des problegravemes de fonctionnement
Section ldquoAESEBUrdquo
8) CONNECTEUR DENTREE INOutre les entreacutees audio analogiques une entreacutee audio numeacuterique SPDIF-AESEBU (AES3) a eacuteteacute preacutevue et peut ecirctre seacutelectionneacutee par le menu de setupLentreacutee requiert une connexion eacutequilibreacutee en utilisant un connecteur XLR avec un cacircble agrave 3 conducteurs de 110ohm torsadeacute
9) CONNECTEUR DE SORTIE OUTCe connecteur permet de relancer le signal audio dans les entreacutees analogiques ou numeacuteriques ou sur les sorties La source doit ecirctre reacutegleacutee par le menu OptionLa connexion sera conforme agrave la mecircme norme que lentreacutee [reacutef8]
Section ldquoRDNETrdquo
10) CONNECTEUR DENTREE DATA INPUTConnecteur RJ45 entreacutee de donneacutees
11) CONNECTEUR DE SORTIE DATA LINKConnecteur RJ45 sortie de donneacutees pour la connexion de seacuterie en cascade
12) VOYANT LUMINEUX ONCe voyant de couleur verte sallume uniquement quand lAC26N a reconnu et est connecteacute agrave luniteacute principale RDNET par lordinateur
13) VOYANT LUMINEUX ACTIVECe voyant de couleur jaune clignote quand une transmission des donneacutees est active entre RDNET et le dispositif
PUSH
P SHU
SHPU
P SHU
PUSH
CONNEXIONS
Audio analogiquesLes connexions eacutequilibreacutees permettent de reacuteduire au minimum le bruit provoqueacute par les cacircbles et dutiliser de longs cacircblesCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLe connecteur XLR doit ecirctre brancheacute avec la broche 1 agrave la masse la broche 2 au chaud (+) et la broche 3 au froid (-) En cas de cacircble blindeacute brancher le blindage agrave la broche 1Les cacircbles de connexion XLR-XLR et XLR-Jack14(63mm) peuvent semployer pour la connexion agrave lAC26N
12
3
Entreacutee
Entreacutee
XLR - femme
XLR - femme
1 2
3
Sortie
Sortie
XLR - Macircle
XLR - Macircle
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2 = Point chaudPhase +VE
Broche 3 =Point froidPhase -VE
Broche 3 =Point froidPhase -VE
Anneau
Manchon
Pointe Point chaudPhase +VE
Anneau = Point froidPhase -VE
ManchonB Masselindeacute
Pointe
Les connexions deacuteseacutequilibreacutees peuvent semployer mecircme si le bruit provoqueacute par les cacircbles augmente Les cacircbles ne peuvent deacutepasser 5m de longCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLes connexions deacuteseacutequilibreacutees peuvent abaisser le niveau du signal entrant de 6dB Pour remeacutedier agrave cet inconveacutenient il faut brancher la broche 3 agrave la masse mecircme si cela augmente le bruit
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
45
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
46
12
3
1 2
3
Pointe Manchon
Pointe = Signal
Broche 3 = Link to Pin 1
Broche 3 = Link to Pin 1
ManchonB Masselindeacute
Audio numeacuteriques (AESEBU)
AESEBU (protocole AES3) est une entreacutee eacutequilibreacutee isoleacutee eacutelectriquement agrave laide dun transformateur Elle permet demployer deux canaux audio dans un seul cacircble bipolaire blindeacute Les caracteacuteristiques du cacircble doivent ecirctre de 3 pocircles impeacutedance 100ohm torsadeacute et blindeacute avec connecteur XLR (AES3 standard)
RJ 45
|1|2|3|4|5|6|7|8|
RDnet
Chaque port RDNet des Control 2 et Control 8 peut ecirctre brancheacute agrave un maximum de 32 dispositifs compatibles placeacutes en cascade Dans lexemple suivant le port de luniteacute de controcircle RDNET CONTROL 2 est relieacute agrave lentreacutee DATA INPUT dun AC26N dont la sortie parallegravele DATA LINK est envoyeacutee agrave lentreacutee de lAC26N successif Dans lexemple [n] est un nombre compris entre 3 et 32 (limite maximale des dispositifs que lon peut relier agrave un sous-reacuteseau)
La longueur totale du cacircble CAT5 dun sous-reacuteseau NE peut PAS deacutepasser 900 megravetres
Le connecteur doit ecirctre relieacute comme 1 ndash disponible pour dautres fonctions (par exemple audio +) 2 ndash disponible pour dautres fonctions (par exemple audio )3 ndash disponible pour dautres fonctions (par exemple masse analogique)4 ndash masse numeacuterique5 ndash masse numeacuterique6 ndash disponible pour dautres fonctions (par exemple alimentation)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
MISE EN MARCHE
Lors de la mise en marche du dispositif linitialisation deacutebute et dure quelques secondes Leacutecran affiche le modegravele le logo et la barre de progression du chargement du programme
En fin de processus dinstallation leacutecran affiche la fenecirctre du menu Meters Pour connaicirctre les indications en deacutetail consulter le paragraphe DESCRIPTION FENETRE MENU Meters
LAC26N est precirct agrave lemploi
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION ET VISUALISATION
Pour entrer dans la fenecirctre du menu principal il faut pousser sur la touche MENU ( ) agrave lavant du dispositifDune page quelconque du menu en poussant sur la touche ESCrdquo ( ) on revient automatiquement sur la page-eacutecran preacuteceacutedente
MENU PRINCIPAL
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Le processeur contient six menus Ils montrent etou configurent les paramegravetres du systegravemeLes menus principaux sont
Meters Visualisation des niveaux des entreacutees et des sorties visualisation du programme utiliseacute et eacutetat mute rapide
Preset Meacutemoriser enregistrer et eacuteliminer les configurations du systegraveme
Matrix seacutelectionner les sorties en fonction du signal entrant
Ch Job configuration de chaque signal
X-Over configurer les freacutequences de coupure et les types de filtres pour chaque sortie
Option attribution des entreacutees et des sorties contraste daffichage la version du micrologiciel les entreacutees et dautres options
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
47
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
48
DESCRIPTION DE LA FENETRE MENU Metersrdquo
Cette fenecirctre permet de visualiser les configurations et leacutetat geacuteneacuteral des entreacutees et des sorties la version du programme utiliseacute son eacutetat et le mode de pilotage du systegraveme
Les menus et les options afficheacutees peuvent se seacutelectionner en tournant la manette ldquoFUNCTIONS SETECTORrdquo ( ) Pour avoir accegraves agrave linteacuterieur de la seacutelection il faut mettre le paramegravetre souhaiteacute en eacutevidence et pousser sur la manette ldquoPush Enterrdquo ( | ) Il faut en faire de mecircme pour seacutelectionner etou modifier les options dans les commandes du menu
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositifAvec des signaux dentreacutee numeacuteriques les indications ldquoArdquo et ldquoBrdquo correspondent agrave lentreacuteeEn tournant la manette ldquoFUNCTIONS SELECTORrdquo [2] on fait deacutefiler en mode cyclique les canaux dentreacutee de sortie et lindication de mute geacuteneacuteral (d) le canal seacutelectionneacute est mis en eacutevidence
b) BARRE DE NIVEAU DE COMPRESSIONMUTE CANAL
COMPRESSION DE SIGNALLa compression du signal est visualiseacutee par le deacutefilement de la barre de droite de haut en bas
MUTE Chaque canal peut ecirctre placeacute en mute Seacutelectionner le canal et pousser sur la manette ldquoPush Enterrdquo [2] pour valider le changement deacutetat Lindication du canal sera remplaceacutee par la lettre M et la barre sera totalement mise en eacutevidencePour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterations
c) BARRE DE NIVEAU DE SIGNALLindication du niveau de chaque canal est signaleacutee par le deacutefilement de la barre de gauche
d) MUTE GENERALIl est possible de mettre simultaneacutement toutes les entreacutees et les sorties en mute Tourner la manette ldquoFUNCTIONS SELECTORrdquo seacutelectionner la lettre M et pousser sur la manette Push EnterPour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterationsLe mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) MODES DE COMMANDEIl affiche le mode dutilisation etou les dispositifs qui sont relieacutes agrave lAC26N
Local = utilisation autonome Aucune connexion agrave un dispositif exteacuterieur
NET = relieacute directement au reacuteseau deacutedieacute RDNet et agrave lordinateur
USB = relieacute directement agrave un ordinateur par cacircble USB
f) INDICATION DETAT DE PARAMETRAGECette indication permet de constater si un ou plusieurs paramegravetre(s) du programme chargeacute aont eacuteteacute modifieacute(s) par rapport au dernier sauvetage
= programme dorigine
= programme avec des paramegravetres modifieacutes
g) PROGRAMME CONFIGURELe chiffre indique le programme chargeacute et utiliseacute par le systegraveme agrave lemplacement de sauvetage Consulter le menu de Preset pour de plus amples deacutetails
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
DESCRIPTION DE LA FENETRE MENU Ch Job
Cette fenecirctre permet dafficher la configuration de chaque canal
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) NIVEAU DU SIGNALIndique le gain du signal Laugmentation de lintensiteacute dun signal est libelleacutee en deacutecibel (dB) Le paramegravetre peut ecirctre seacutelectionneacute de -8000dB agrave +2000dB avec des pas de 001dB Une augmentation de 6dB est eacutegale approximativement au redoublement agrave leacutechelle lineacuteaire du niveau du signal sous tensionAvec un gain supeacuterieur agrave 0dB le signal est amplifieacute tandis quavec un gain infeacuterieur agrave 0dB le signal est atteacutenueacute
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
49
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
50
c) DELAI DU SIGNAL (DELAY)Le signal audio reproduit peut ecirctre retardeacute pour permettre lalignement acoustique Cela compense les diffeacuterentes positions des diffuseurs pendant linstallation et la reproduction sonore Il se libelle en mS Le paramegravetre peut ecirctre seacutelectionneacute de 00mS agrave 729mS avec un pas de 01mSPour aligner un signal audio il est possible dutiliser la formule suivante
Deacutelai = (GAPx1000)344
Deacutelai = ms (en millisecondes)GAP = distance du diffuseur du point de reacutefeacuterence (en megravetres)Vitesse du son = 344ms
d) MUTEChaque canal peut ecirctre placeacute en mute La mecircme commande peut ecirctre activeacutee dans la fenecirctre du menu meters NB Le mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) PhasePermet la rotation de phase de 180deg par rapport au signal entrantCette rotation permet loptimisation surtout des basses freacutequences dans les installations complexes
f) EGALISATIONCette commande ouvre la fenecirctre du menu deacutegalisation de chaque canal Elle sert surtout pour corriger une ou plusieurs freacutequences qui doivent ecirctre atteacutenueacutees ou augmenteacutees
M M
LAC26N gegravere 12 filtres par canal dentreacutee et sortie avec trois types de configurations diffeacuterentes - Leacutegaliseur PEQ (peaking equalizer) est ideacuteal pour identifier isoler et
corriger une seule plage de freacutequences bien deacutetermineacutee Toutes les freacutequences passent mais il augmente ou diminue uniquement celles autour de la freacutequence centrale pour une bande preacutecise et un gain deacutefini
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessus de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessous de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
f Numeacuterotation des 12 filtres disponibles pour cette entreacutee ou cette sortie1
f Le type de filtre est afficheacute 2
Dis Deacutesactiveacute (absent)
PEQ Peaking equlizer
Sh H Filtre high-shelf
Sh L Filtre high-shelf
Exemples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
REMARQUELe paramegravetre Bw deacutetermine le champ de freacutequences adjacent agrave la freacutequence configureacutee ougrave est activeacute le filtre Plus la valeur Bw est eacuteleveacutee plus vaste est le champ de freacutequences (1Bw=1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONCette commande ouvre la fenecirctre du menu de compression de chaque canal
g1) TresholdIdentifie le seuil ougrave commence le rapport de compression La valeur de base 11
g2) RatioIndique le rapport de conversion entre le signal entrant et le signal sortant
g3) Post Gain Attach Release HoldCes donneacutees deacutependent du rapport de conversion que lon veut obtenir - Post Gain est le gain de sortie- Attack est le temps dattaque - Release est le temps de relacircchement- Hold est le temps de maintien
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
52
DESCRIPTION DE LA FENETRE MENU Preset
Cette fenecirctre permet de meacutemoriser jusquagrave 32 configurations dans lAC26NLe fabricant fournit le systegraveme avec un programme configureacute et enregistreacute en position 0 et non susceptible deacutecrasement
032 Elle indique lemplacement de sauvetage de la configurationCe numeacutero apparaicirct dans la fenecirctre Meters en position (g) A tout moment le programme utiliseacute peut ecirctre afficheacute par lutilisateur
Empty Preset Cest le nom qui est associeacute au numeacutero de lemplacement quand aucune configuration (vide) nest enregistreacutee
Local preset Local preset est le nom qui est associeacute au numeacutero de lemplacement quand on enregistre une configuration NB = Il est possible denregistrer une configuration avec lenom souhaiteacute de 16 lettres tout au plus agrave condition que lonutilise linterface via lordinateur
Le nom du programme assigneacute est indiqueacutePour toucher agrave lapplication 3 choix soffrent agrave vous
Save Le programme est enregistreacute en meacutemoire de lAC26N
Del Le programme est effaceacute
Load Le programme est chargeacute et precirct agrave lemploi
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
51
DESCRIPTION DE LA FENETRE MENU X-Over
Cette fenecirctre permet de seacutelectionner un filtre passe bas un filtre passe haut ou par la combinaison des deux de creacuteer un filtre passe bande pour chaque sortieLe filtre actif est un Linkwitz-Riley qui permet de seacutelectionner la pente de 12dBoct 24dBoct ou 48dBoct et sa freacutequence de coupure
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) CANAUX DE SORTIE
Les connecteurs de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) FILTRE CROSSOVERSeacutelectionner le filtre selon les besoins Il est possible de seacutelectionner
Dis Aucun filtre activeacute
HP Filtre passe-haut laisse passer uniquement la partie de signal audio supeacuterieure agrave la freacutequence de coupure
LP Filtre passe-bas laisse passer uniquement la partie de signal audio infeacuterieure agrave la freacutequence de coupure
Configuration du filtre Passe-haut Passe-bas
Rien Dis Dis
Passe-haut HP Dis
Passe-bas Dis LP
Passe-bande HP LP
12dBoct
24dBoct
Hz
dB
Ga
in 48dBoct
12dBoct
24dBoct
Hz
dB
Ga
in
48dBoct
c) PENTE DATTENUATIONSeacutelectionner la pente datteacutenuation du signal audio en fonction de la diminution que lon veut obtenir Plus la pente datteacutenuation est eacuteleveacutee agrave eacutegaliteacute de freacutequence de coupure plus eacuteleveacutee sera la seacutelection du signal Il est possible de seacutelectionner
12 correspond agrave 12dboct
24 correspond agrave 24dboct
48 correspond agrave 48dboct
d) FREQUENCE DE COUPUREElle permet de reacutegler la freacutequence de passage des freacutequences infeacuterieures (filtre passe-bas) ou des freacutequences supeacuterieures (filtre passe-haut) uniquementLe choix de la coupure deacutepend de la reproduction que lon veut obtenirLuniteacute de mesure utiliseacutee est lHz
Hz
Hz
dB
dB
Ga
in
f0
f0
0dB0dB
0dB
-6dB
freacutequence
freacutequence
freacutequence
freacutequence
Ga
in
f0
0dB
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
53
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
54
DESCRIPTION DE LA FENETRE MENU Matrix
Elle permet de seacutelectionner le signal entrant agrave utiliser comme source pour chaque sortie
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) CANAUX DE SORTIEIdentification du canal sortant agrave reacutegler
b) IDENTIFICATIONS DES ENTREESSeacutelectionner le type de signal agrave associer agrave chaque sortie en fonction des besoins Il est possible de seacutelectionner
In A Le signal entrant A est associeacute
In B Le signal entrant B est associeacute
In A+B La somme algeacutebrique des deux signaux entrants A et B est associeacutee
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
DESCRIPTION DE LA FENETRE MENU Option
Permet dafficher les reacuteglages du systegraveme comme lassignation des entreacutees et des sorties latteacutenuation le contraste de laffichage et la version du logiciel
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcCette option permet de reacutegler le type de signal audio entrant
An In =signaux audio analogiques (entreacutees ldquoArdquo et ldquoBrdquo)
Dig In =signaux audio numeacuteriques (entreacutee AESEBU)
DigOut SrcCette option permet de seacutelectionner la source audio qui sera adresseacutee sur le connecteur AESEBU OUT (sortie numeacuterique)
An In = signaux audio des entreacutees analogiques
Dig In =signaux audio sur lentreacutee numeacuterique
OUT 1-2 = signaux audio sur les sorties 1 et 2
OUT 3-4 = signaux audio sur les sorties 3 et 4
OUT 5-6 = signaux audio sur les sorties 5 et 6
Input ModePermet de configurer les entreacutees
Indip = sont indeacutependantes et autonomes Ne sont soumises agrave aucun type de lien
Linked = sont unies et fonctionnent en mode steacutereacuteo Les compresseurs les filtres les deacutelais le volume sont identiques pour les deux canaux
Atten PadIndique le mode de reacuteglage du seacutelecteur ldquo-6dBrdquo placeacute agrave larriegravere [reacutef 5] Il faut activer ce seacutelecteur quand les niveaux dentreacutee analogiques sont trop eacuteleveacutes Le seacutelecteur sactive uniquement par le bouton Dans le menu il sagit dune simple visualisation
0dB = seacutelecteur non activeacute Les signaux dentreacutee sont identiques agrave la source entrante
-6dB = seacutelecteur activeacute Les signaux entrants sont atteacutenueacutes de -6dB par le processeur interne
ContrastIl permet de reacutegler le contraste de laffichage agrave cristaux liquides pour compenser la diffeacuterence de luminositeacute avec le lieu dinstallation Une plus grande clarteacute de laffichage permet de naviguer convenablement et rapidement dans les menusLe reacuteglage agrave la sortie de lusine du fabricant est de 60
10 plus clair 60 plus fonceacute 100
Fw VersIndique la version du logiciel du processeur
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
55
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
56
DONNES TECHINIQUES
PERFORMANCES AUDIOReacuteponse en freacutequence +- 01dB (20 to 30kHz)Plage dynamique 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsion 0002 (1kHz +4dBu)
PERFORMANCES AUDIO NUMERIQUES Processeur DSP 2856-bit Freacutequence de traitement des donneacutees 48KHzConvertisseurs analogiques 24-bit BURR BROWNDeacutelai de propagation 15msMeacutemorisations des configurations 32 preset
CONTROLES Affichage LCD graficoBoutonsCommandes ESC - MENU - FUNCTIONS SELECTION
ENTERENTREESSORTIESEntreacutee analogique ndeg2 x XLR (3 broches femelle)
Impeacutedance dentreacutee gt10KOhmNiveau maximum +21dBu senza PAD
+27dBu con PADSortie analogique ndeg6 x XLR (3 broches macircle )
Impeacutedance de sortie 50OhmNiveau maximum +21dBuType Balanceacute
Entreacutee numeacuterique ndeg1x XLR (3 broches femelle)Type SPDIF-AESEBU (AES3)
Sortie numeacuterique ndeg1x XLR (3 broches macircle )Type conforme agrave la norme de lentreacutee
EntreacuteesSortie Rdnet ndeg2 x XLR RJ45 (cacircble CAT 5)USB Type B
PARAMETRES DE CONTROLE DU SONGain -80dB a +20dB eacutetape 01dBDeacutelai Entreacutee 0 a 729mS eacutetape 01 mS
Sortie 0 a 340mS eacutetape 01mSRotation de phase 0deg - 180deg
COMPRESSIONSeuil -80dB a +20dB eacutetape 01dBRapport 11 a Inf1 eacutetape 001Gain agrave la sortie 0dB a 40dB eacutetape 01dBTemps dattaque 1mS a 1000mS eacutetape 01mSTemps de relacircchement 1mS a 1000mS eacutetape 01mSTemps de maintien 1mS a 1000mS eacutetape 01mS
EGALISEURS12 eacutegaliseurs pour chaque entreacutee et sortieType PEQ (parameacutetrique) Hi-shelf Lo-sheft
Freacutequence 20Hz a 20KHz eacutetape 1HzGain -30dB a +15dB eacutetape 001dBBande 005dB a 2dB eacutetape 001dB (uniquement pour PEQ)
FILTRES CROSSOVERFiltre Linkwitz Riley
Type HF high-shelfLF low-shelf
Pente 12dBoct - 24dBoct - 48dBoctFreacutequence de coupure 5Hz a 20KHz eacutetape 1Hz
ALIMENTATION Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)POIDS 19Kg
Remarques Speacutecifications sujettes agrave modifications sans preacuteavis
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
2 VIE ATTIVO2 WAY ACTIVE
3 VIE PASSIVO3 WAY PASSIVE
L
L
A
A
HIGH L
MID L
LOW HIGHMID RHIGHMID L
LOW L
HIGH R
MID R
LOW R
R
R
B
B
1
1
2
2
3
3
456
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
Menu Matrix configurationMatrix
57 58
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
EROUIG ATRIX TNM
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
OU
TP
UT
1
OU
TP
UT
2
OU
TP
UT
3
OU
TP
UT
4
OU
TP
UT
5
OU
TP
UT
6
AE
S-E
BU
OU
TP
UT
INP
UT
A
AE
S-E
BU
INP
UT
INP
UT
B
D D D D D D
D D
A A A A A A
A SA
MP
LE
RA
TE
CO
NV
A
LIN
KA
BL
E
SC
HE
MA
A B
LO
CC
HI -
BL
OC
K D
IAG
RA
MB
LO
CK
SC
HA
LT
BIL
D -
SC
HE
MA
S F
ON
CT
ION
NE
LS
LINE ARRAY SUB MONO ATTIVO
LINE ARRAY SUB MONO ACTIVEINGRESSI - INPUT
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
L
L
L
A
A
A
AESEBU IN
AESEBU IN
AESEBU IN
AESEBU OUT
AESEBU IN
AESEBU IN
AESEBU OUT
R
R
R
LR
B
B
B
123456
HIGHMID L
HIGHMID L HIGHMID R
HIGHMID R
LOW L LOW R
LAYER
DISPLAY MEMORY
FADER MODE
LAYER
DISPLAY MEMORY
FADER MODE
Ingresso ANALOGICO
ANALOG Input
Collegamento in cascata
Link connections
Ingresso DIGITALE
DIGITAL inputA B
BALANCED AUDIO INPUTS
-6dB
PUSH PUSH
IN OUT
AES EBUPUSH
Oppure
or
Oppure
or
Menu Option configurationOption
Menu Option configurationOption Menu Option configurationOption
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type Analog
AES out An In
Input type Analog
AES out An In
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
59 60
InA-B Src Dig InInA-B Src Dig InInA-B Src An InInA-B Src An In
frequenzaHz
dB
Gu
ad
ag
no
60 200 2800
0dB0dB
-6dB
Esempio di un sistema a 3-vie
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
Out 1 Out 2 Out 3
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Esempio di un sistema a 3-vie
61 62
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
26NAC 26NAC
R TE
DO
R
MO LEU O R CE S
E O TR L A
S O
O C ND I P
P hsuernE t
o su cti nF nel rS e tc o
E CSME UN
IGCHTE OL SN EOBd
ocaL l
M
0
484
467
430
44
31
75
12
7
DIMENSIONI DIMENSIONSABMESSUNGEN DIMENSIONS
EINLEITUNG
Verpackungsinhalt
Eigenschaften
AC26N ist ein digitaler Audio-Prozessor fuumlr die Verwaltung von Audio-Systemen der fuumlr feste und mobile Installationen entwickelt wurde AC26N benutzt die modernste Technologie mit 2856 bit-Prozessoren und 24-bit-ADDA-Wandlern mit hoher Leistungsfaumlhigkeit Die verfuumlgbaren Funktionen des Prozessors sind Ein- und Ausgangsstufen Verzoumlgerung (delay) Polaritaumlt 12 Equalizer-Frequenzen fuumlr Ein- und Ausgangskanal viele Crossover-Wahlmoumlglichkeiten und Limiter mit hoher Leistung Die Filter-Kontrolle hat eine Aufloumlsung von 1 Hz Die Ein- und Ausgaumlnge koumlnnen mit unterschiedlichen Einstellungen geregelt werden um allen Anforderungen gerecht zu werden AC26N kann in Echtzeit kontrolliert werden und jeder Parameter kann am Frontpaneel und vom Computer mit intuitiver graphischer Schnittstelle mittels Software DVA Network zugaumlnglich und einer Netzverbindung RDnet oder uumlber USB eingestellt werdenDie SW-Aktualisierung fuumlr CPU und DSP uumlber PC erlaubt die Vorrichtung auf dem aktuellen Stand zu halten Man kann 32 vorgesehene Konfigurationen speichern und aufrufen
- AC26N - Bedienungsanleitung- Software-CD- Versorgungskabel
- 2 Ein- und 6 Ausgaumlnge mit flexibler Adressierung- Adressierbarer Stereo-Ein- und Ausgang AESEBU - DSP 2856-bit- AD-Wandler BURR BROWN 24-bit mit hoher Leistungsfaumlhigkeit- Aufloumlsungsfrequenz der Filter 1 Hz - 12 parametrische Equalizer fuumlr jeden Ein- und Ausgang- 2 Crossover-Filter fuumlr jeden Ausgang mit auswaumlhlbarer Neigung 122448dBoct- DRC Multikonfiguration mit hoher Leistungsfaumlhigkeit fuumlr die Konfiguration des
Limitersder Kompression jedes Ein- und Ausgangs- Einstellbare dB-Stufe Polaritaumlt und Verzoumlgerung (delay) fuumlr jeden Ein- und Ausgang- Firmware-Aktualisierung uumlber PC- Graphisches LCD-Display- 32 Voreinstellungen vom Benutzer einstellbar- USB-Schnittstelle fuumlr die Kontrolle und Konfiguration mit dem Computer- Schnittstelle RDnet welche erlaubt bis zu 256 fern liegende Vorrichtungen
zu kontrollieren
PC
PC
RDNET control(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FUNKTIONEN VORDERSEITE
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
BEDIENUNGEN UND FUNKTIONEN
1) DISPLAYDas graphische LCD-Display erlaubt die Informationen des AC26N ohne einen Computer zu benutzen anzuzeigen und zu editieren Der Kontrast kann im Hauptmenuuml eingestellt werden
2) DREHGRIFF Functions Selector UND Push EnterDiese Kontrolle erlaubt sich in den Menuumls auf dem Display zu bewegen und die Parameter auszuwaumlhlen und zu veraumlndernDrehung des Drehgriffes (Functions Selectors)- Man kann sich innerhalb der verschiedenen Menuumlseiten bewegen- Erlaubt die Veraumlnderung der ausgewaumlhlten ParameterDruck des Drehgriffes (Push Enter)- Erlaubt die AuswahlBestaumltigung der Parameter
3) Taste ldquoESCrdquo Diese Kontrolle erlaubt die angezeigten Menuumls zu verlassen oder zur vorherigen Anzeige zuruumlckzukehren
4) Taste ldquoMenuumlrdquo Diese Kontrolle erlaubt den direkten Zugang zum Hauptmenuuml
Deuts
chD
euts
chB
ed
ien
un
gsan
leit
un
gB
ed
ien
un
gsan
leit
un
g
29
Deuts
chD
euts
chB
ed
ien
un
gsan
leit
un
gB
ed
ien
un
gsan
leit
un
g
30
DVA USB Manager
Die Firmware des Verstaumlrkermoduls kann uumlber den USB-Anschluss aktualisiert werdenUm diesen Vorgang zu ermoumlglichen und zu vereinfachen wurde ein dediziertes Programm entwickelt das beim Hersteller angefordert und auf einen Computer installiert werden muss
Wir empfehlen die Software DVA USB Manager direkt von der Webseite dB Technologies (wwwdbtechnologiescom) im Abschnitt laquoSoftware amp Controllerraquo herunterzuladen
DVA Network
AC26N ist mit einer eigenen als RDNET bezeichneten Netzschnittstelle ausgestattet dank der es uumlber ein Interface (RDNET Control) an einen Computer angeschlossen werden koumlnnenHierzu wurde ein Kommunikationsprotokoll entwickelt mit dem die Daten empfangen und gesendet werden Dank dieser Verbindung koumlnnen die Lautsprecherparameter wie Ausgangsleistung Verstaumlrkertemperatur Limiterstatus usw in Echtzeit kontrolliert werden Auszligerdem koumlnnen verschiedene Entzerrungen ausgewaumlhlt bzw neue erstellt werden oder die gewuumlnschte Lautstaumlrke eingestellt werden
Wir empfehlen die Software DVA_Network direkt von der Webseite dB Technologies (wwwdbtechnologiescom) im Abschnitt laquoSoftware amp Controllerraquo herunterzuladenDOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
RUumlCKWANDANSCHLUumlSSE
1586 75 141210 11 13 169 17
14) USB-SteckverbinderDieser USB-Steckverbinder (Typ B) erlaubt den Prozessor an einem Computer anzuschlieszligen um die Firmware mit dem speziellen Programm (DVA Network) zu kontrollieren und zu aktualisieren
15) STROMANSCHLUSS MAINSErlaubt den Anschluss des mitgelieferten Versorgungskabels
16) SICHERUNGSTRAumlGER FUSEAufnahme fuumlr die Netz-Sicherung
17) HAUPTSCHALTER POWERDer Schalter erlaubt das Aus- und Einschalten des Audio-Controllers
BEDIENUNGEN UND FUNKTIONEN
5) WAHLSCHALTER -6dBDer Wahlschalter erlaubt das Level des analogen Eingangs XLR [6] um 6 dB zu verringern und gleichzeitig das hohe Ausgangslevel der Mixer oder anderer Audio-Vorrichtungen auszugleichen Wenn der Balken des Signallevels der Eingaumlnge auf dem Display [1] immer auf Maximum steht zeigt dies an dass das Signallevel am Eingang hoch ist und es wird empfohlen die Daumlmpfung -6dB zu benutzenIm Menuuml Option ist es moumlglich zu kontrollieren ob der Wahlschalter aktiviert ist
6) STECKVERBINDER AM EINGANG A UND BAuf Leitungslinie ausgeglichene EingaumlngeSie koumlnnen auch XLR-Steckdosen aufnehmen
7) AUSGANG-STECKVERBINDER ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo UND ldquo6rdquoAuf Leitungslinie ausgeglichene Ausgaumlnge Sie koumlnnen auch XLR-Stecker aufnehmen
Darauf achten dass die Ausgaumlnge korrekt entsprechend der Einstellungen der einzelnen Kanaumlle an den Lautsprechern oder Verstaumlrkern angeschlossen sind um Schaumlden und Fehlfunktionen vorzubeugen
Abschnitt ldquoAESEBUrdquo
8) EINGANGS-STECKVERBINDER INZusaumltzlich zu den analogen Audio-Eingaumlngen wurde ein digitaler Audio-Eingang SPDIF-AESEBU (AES3) vorgesehen der uumlber das Setup-Menuuml ausgewaumlhlt werden kannDer Eingang erfordert einen ausgeglichenen Anschluss mit einem XLR-Steckverbinder mit einem verdrillten Kabel mit 3 Leitern von 110 Ohm
9) AUSGANGS-STECKVERBINDER OUTDieser Steckverbinder erlaubt das Audiosignal an den analogen oder digitalen Eingaumlngen oder Ausgaumlngen zu verteilen Die Quelle muss uumlber das Menuuml Option eingestellt werdenDer Anschluss muss demselben Standard des Eingang entsprechen [Ref 8]
Abschnitt ldquoRDNETrdquo
10) EINGANGS-STECKVERBINDER DATA INPUTSteckverbinder RJ45 fuumlr den Dateneingang
11) AUSGANGS-STECKVERBINDER DATA LINKSteckverbinder RJ45 fuumlr den Datenausgang Fuumlr die serielle Kaskaden-Verbindung
12) LEUCHTANZEIGE ONDiese gruumlne Anzeige leuchtet nur wenn AC26N uumlber den Computer mit der Haupteinheit RDNET verbunden ist und diese erkannt hat
13) LEUCHTANZEIGE ACTIVEDiese gelbe Anzeige blinkt wenn eine Datenuumlbertragung zwischen RDNET und der Vorrichtung aktiv ist
PUSH
P SHU
SHPU
P SHU
PUSH
ANSCHLUumlSSE
Analoge Audio-AnschluumlsseDie ausgeglichenen Anschluumlsse erlauben die Geraumlusche der Kabel auf ein Minimum zu verringern und so die Benutzung langer Kabel zuzulassenDiese Anschluumlsse koumlnnen sowohl an den Ein- als auch an den Ausgaumlngen benutzt werdenDer XLR-Steckverbinder muss mit Pin 1 an Masse Pin 2 am Pluspol (+) und Pin 3 am Minuspol (-) angeschlossen werden Bei einem abgeschirmten Kabel muss die Abschirmung an Pin 1 liegenDie Verbindungskabel XLR-XLR und XLR-Jack 14 (63 mm) koumlnnen fuumlr den Anschluss
12
3
Eingang
XLR weiblichen
Pin 3 = MinuspolErkaumlltungphase -VE
Pin 3 = MinuspolErkaumlltungphase -VE
1 2
3
Ausgang
XLR maumlnnlichen
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Ring
Schaft
Spitze = PluspolWaumlrmephase +VE
Ring = MinuspolErkaumlltungphase -VE
Schaft=SchirmMasse
Spitze
Die nicht ausgeglichenen Anschluumlsse koumlnnen auch benutzt werden wenn die Kabelgeraumlusche ansteigen und diese Kabel duumlrfen nicht laumlnger sein als 5 MeterDiese Anschluumlsse koumlnnen sowohl an den Ein- als auch an den Ausgaumlngen benutzt werdenDie nicht ausgeglichenen Anschluumlsse koumlnnen das Signallevel am Eingang um 6 dB verringern um dem vorzubeugen muss Pin 3 an Masse angeschlossen werden obwohl dies das Geraumlusch verstaumlrken kann
12
3
Eingang
XLR weiblichen
1 2
3
Ausgang
XLR maumlnnlichen
Spitze Schaft
Spitze = Signal
Schaft=SchirmMasse
Pin 3 = zu Pin 1 gebruumlckt
Pin 3 = zu Pin 1 gebruumlckt
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
31
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
32
Digitales Audio (AESEBU)AESEBU (Protokoll AES3) ist ein ausgeglichener und uumlber einen Transformator elektrisch isolierter Eingang Er erlaubt die Benutzung von zwei Kanaumllen an einem einzigen abgeschirmten bipolaren Kabel Das gedrillte Kabel muss 3-polig sein eine Impedanz von 100 Ohm haben und mit einem XLR-Steckverbinder (AES3 Standard) abgeschirmt sein
RdnetJeder Port RDNet an Control 2 und Control 8 kann an max 32 kompatiblen Vorrichtungen die in Kaskade geschaltet sind angeschlossen werden Im nachstehenden Beispiel ist der Port der Kontrolleinheit RDNET CONTROL 2 am Eingang DATA INPUT eines AC 26N angeschlossen dessen paralleler Ausgang DATA LINK zum Eingang des naumlchsten AC26N geht Im Beispiel ist [n] eine Nummer zwischen 3 und 32 (maximale Anzahl der anschlieszligbaren Vorrichtungen an nur einem Netz)
RJ 45
|1|2|3|4|5|6|7|8|
Die Gesamtlaumlnge des Kabels CAT5 eines Unternetzes kann NICHT laumlnger als 900 Meter sein
Der Steckverbinder muss wie folgt angeschlossen sein1 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio +) 2 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio -)3 ndash Verfuumlgbar fuumlr andere Funktionen (zB analoge Masse)4 ndash digitale Masse5 ndash digitale Masse6 ndash Verfuumlgbar fuumlr andere Funktionen (zB Versorgung)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
EINSCHALTEN
Beim Einschalten der Vorrichtung startet die Initialisierung die einige Sekunden lang dauert Auf dem Display wird das Modell das Logo und der Fortschrittsbalken der Ladung des Programms angezeigt
Nach der Initialisierung erscheint auf dem Display das Menuumlfenster Meters Um die Angaben im Detail zu erfahren beziehen Sie sich bitte auf das Kapitel BESCHREIBUNG DES MENUumlFENSTERS Meters
AC26N kann jetzt benutzt werden
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
MENUrsquo PRINCIPALE
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Die sechs Menuumls im Prozessor zeigen undoder konfigurieren die Systemparameter
Anzeige der Levels der Ein- und Ausgaumlnge Anzeige des benutzten Programms und dessen Status Mute schnell
Speicherung Speicherung und Eliminierung der Systemkonfigurationen
Auswahl der Ausgaumlnge je nach Eingangssignal
Konfiguration jedes einzelnen Kanals
Konfiguration der Schnittfrequenzen und der Filtertypen fuumlr jeden einzelnen Ausgang
Zuordnung der Ein- und Ausgaumlnge Kontrast des Displays Firmware-Version Eingaumlnge und andere Optionen
Das Menuuml und die einzelnen Optionen der Anzeige koumlnnen durch Drehen des Drehgriffes FUNKTIONS SELECTOR ( ) ausgewaumlhlt werden
Die Hauptmenuumls sind
Meters
Preset
Matrix
Ch Job
X-Over
Option
Um die Auswahl zu treffen muss der gewuumlnschte Parameter auswaumlhlt und der Drehgriff Push Enter( | ) gedruumlckt werdenDas selbe Verfahren muss fuumlr die Auswahl undoder die Aumlnderung der Optionen innerhalb der Menuumlpunkte angewendet werden
BESCHREIBUNG DES MENUumlFENSTERS Meters
Diese Seite erlaubt die Konfigurationen und den allgemeinen Status der Ein- und Ausgaumlnge der benutzten Programmversion dessen Status und die Steuerung des Systems anzuzeigen
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
KONFIGURATION UND ANZEIGE
Um in das Fenster des Hauptmenuumls zu gelangen muss die Taste Menuuml ( ) auf der Frontseite der Vorrichtung gedruumlckt werdenMit der Taste ESC ( ) kehrt man von jeder Seite des Menuumls auf die vorherige Seite zuruumlck
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
33
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
34
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziertBei den digitalen Eingangssignalen entspricht die Angabe A und B dem EingangDreht man den Drehgriff FUNCTIONS SELECTOR [2] durchlaumluft man zyklisch die Ein- und Ausgangskanaumlle und die Angabe Mute allgemein (d) der ausgewaumlhlte Kanal wird hervorgehoben
b) BALKEN FUumlR DAS KOMPRESIONSLEVELMUTE KANAL
SIGNALKOMPRESSIONDie Signalkompression wird durch das Gleiten des rechten Balkens von oben nach unten angezeigt
MUTE Jeder einzelne Kanal kann auf Mute gestellt werden Den Kanal auswaumlhlen und den Drehgriff Push Enter [2] druumlcken um die Aumlnderung des Status zu bestaumltigen Die Angabe des Kanals wird durch den Buchstaben M ersetzt und der Balken wird komplett hervorgehobenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werden
c) BALKEN DES SIGNALLEVELSDie Anzeige des Levels jedes einzelnen Kanals wird durch das Gleiten des linken Balkens angezeigt
d) MUTE ALLGEMEINEs ist moumlglich alle Ein- und Ausgaumlnge gleichzeitig auf Mute zu schalten Den Drehgriff FUNCTIONS SELECTOR drehen den Buchstaben M waumlhlen und dann den Drehgriff Push Enter druumlckenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werdenDie allgemeine Stummschaltung hat eine houmlhere Prioritaumlt als die Stummschaltung der einzelnen Kanaumlle
e) ANSTEUERUNGSARTENEs wird angezeigt wie AC26N benutzt wird undoder an welchen Vorrichtungen es angeschlossen ist
= Benutzung stand-alone Kein Anschluss an einer externen Vorrichtung
= Direkt am Netz RDnet und am Computer angeschlossen
= Uumlber USB-Kabel direkt am Computer angeschlossen
f) ANZEIGE DES STATUS DER EINSTELLUNGENHier wird angezeigt ob einer oder mehrere Parameter des geladenen Programms im Vergleich zur letzten Speicherung veraumlndert wurden
Original-Programm
Programm mit veraumlnderten Parametern
g) EINGESTELLTES PROGRAMMDie Nummer zeigt das vom System geladene und benutzte Programm in Bezug auf die Lokalisierung der Speicherung an Fuumlr weitere Details beziehen Sie sich bitte auf das Menuuml Preset
Local
NET
USB
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
BESCHREIBUNG DES MENUumlFENSTERS Ch Job
Dieses Fenster erlaubt die Anzeige der Konfiguration jedes einzelnen Kanals
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) SIGNALLEVELZeigt die Signalstaumlrke an Das Ansteigen der Signalintensitaumlt wird in Dezibel (dB) ausgedruumlckt Der Parameter kann zwischen -8000 dB und +2000 dB in Schritten von 001 dB ausgewaumlhlt werden Ein Anstieg von 6 dB ist fast gleich eine Verdoppelung in linearer Skala des Spannungswertes des SignalsBei einer Staumlrke von 0 dB wird das Signal verstaumlrkt waumlhrend es ein einer Staumlrke von weniger als 0 dB abgeschwaumlcht wird
c) VERZOumlGERUNG DES SIGNALS (DELAY)Das wiedergegebene Audio-Signal kann verzoumlgert werden um die akustische Ausrichtung zu erlauben Dies gleicht die verschiedenen Positionen der Lautsprecher bei der Installation und Klangwiedergabe aus und wird in mS ausgedruumlckt Der Parameter kann zwischen 00 mS und 729 mS in Schritten von 01mS ausgewaumlhlt werden
Um ein Audiosignal auszurichten kann folgende Formel benutzt werden
Verzoumlgerung = GAPx1000)344
Verzoumlgerung = mS (in Millisekunden ausgedruumlckt)GAP = Abstand des Lautsprechers vom Referenzpunkt (in Metern ausgedruumlckt)Klanggeschwindigkeit = 344 ms
d) MUTEJeder einzelne Kanal kann auf Mute gestellt werden Derselbe Befehl kann im Fenster des Menuumls Meters aktiviert werden PS Die al lgemeine Stummschaltung hat eine houmlhere Priori taumlt als die Stummschaltung der einzelnen Kanaumlle
e) PHASEErlaubt die Phasenrotation um 180deg zum EingangssignalDiese Rotation erlaubt vor Allem die Optimierung der niederen Frequenzen bei komplexen Installationen
f) ENTZERRUNGENDieser Befehl oumlffnet das Menuumlfenster fuumlr die Entzerrung des einzelnen Kanals Er wird vor Allem benutzt um eine oder mehrere Frequenzen zu korrigieren die gedaumlmpft oder verstaumlrkt werden muumlssen
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
35
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
36
AC26N verwaltet 12 Filter fuumlr jeden einzelnen Ein- und Ausgangskanal mit drei verschiedenen Konfigurationen- Equalizer PEQ (peaking equalizer) ist ideal um nur ein bestimmtes Frequenzband
zu identifizieren zu isolieren und zu korrigieren Es gehen alle Frequenzen durch aber nur die um die mittlere Frequenz steigt und sinkt um eine bestimmte Bandbreite und eine bestimmte Staumlrke
- Equalizer High-Shelf geht alle Frequenzen durch aber die Frequenzen uumlber der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
- Equalizer Low-Shelf geht alle Frequenzen durch aber die Frequenzen unter der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
f Nummerierung der 12 verfuumlgbaren Filter fuumlr diesen Ein- oder Ausgang1
f2 Es wird der Filtertyp angezeigt
Dis Ausgeschaltet (nicht vorhanden)
PEQ Peaking equalizer
Sh H Filter High-Shelf
Sh L Filter Low-shelf
Beispiele PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
ANMERKUNGDer Parameter Bw legt das Frequenzfeld neben der eingestellten Frequenz fest wo der Filter aktiviert wird je houmlher der Bw-Wert desto houmlher das Frequenzfeld (1Bw=1 Oktave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filter High-Shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filter Low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) KOMPRESSIONDieser Befehl oumlffnet das Menuumlfenster fuumlr die Kompression des einzelnen Kanals
g1) TresholdIdentifiziert die Schwelle an der das Kompressionsverhaumlltnis beginnt Der Basiswert 11
g2) RatioIdentifiziert das Kompressionsverhaumlltnis zwischen dem Ein- und Ausgangssignal
g3) Post Gain Attach Release HoldDiese Daten entsprechen dem Kompressionsverhaumlltnis das man erreichen moumlchte
Post Gain ist der Gewinn am AusgangAttack ist die Anschlusszeit Release ist die ReleasezeitHold ist die Beibehaltungszeit
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
BESCHREIBUNG DES MENUumlFENSTERS Preset
Dieses Fenster erlaubt bis zu 32 Konfigurationen im AC26N zu speichernDer Hersteller liefert das System mit einem voreingestellten Programm das auf Position 0 gespeichert ist und nicht uumlberschrieben werden kann
032 Es zeigt die Lokalisierung der Speicherung der KonfigurationDiese Nummer erscheint auch im Fenster Meters auf der Position (g) Das benutzte Programm kann jederzeit vom Benutzer angezeigt werden
Empty Preset Es ist der Name der der Nummer der Lokalisierung zugeordnet wird wenn keine Einstellung gespeichert ist (leer)
Local preset Es i s t de r Name de r de r Nummer de r Loka l i s i e rung zugeordnet wird wenn eine Konfiguration gespeichert wird
ANMERKUNG = Man kann eine Einstellung mit dem gewuumlnschten Namen mit max 16 Buchstaben nur speichern wenn man die Schnittstelle uumlber den Computer benutzt
Bei der Wahl eines Programms erscheint folgendes Fenster
Anzeige des Namens der dem Programm zugeordnet istUm auf die Anwendung einzuwirken stehen 3 Auswahlmoumlglichkeiten zur Verfuumlgung
Das Programm wird im Speicher des AC 26N gespeichert
Das Programm wird geloumlscht
Das Programm wird geladen und ist bereit fuumlr die Benutzung
Save
Del
Load
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
37
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
38
BESCHREIBUNG DES MENUumlFENSTERS X-Over
Dieses Fenster erlaubt fuumlr jeden Ausgang einen Bassdurchgangsfilter einen Hochdurchgangsfilter oder mittels Kombination von beiden einen Banduumlbergangsfilter zu waumlhlenDer Filter ist ein Linkwitz-Riley wo man die Neigung von 12 dBoct 24dBoct oder 48 dBoct und die entsprechende Schnittfrequenz auswaumlhlen kann
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) AUSGANGSKANAumlLE
Die Steckverbinder am Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) FILTER CROSSOVERDen Filter nach Bedarf waumlhlen Man kann folgendes auswaumlhlen
Dis Kein Filter aktiviert
HP Hochdurchgangsfilter nur den Teil des Audiosignals durchlassen der uumlber der Schnittfrequenz liegt
LP Bassdurchgangsfilter nur den Teil des Audiosignals durchlassen der unter der Schnittfrequenz liegt
Filter-Konfiguration Tiefpass Hochpass
Nichts Dis Dis
Hochpass HP Dis
Tiefpass Dis LP
Bandpass HP LP
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
c) DAumlMPFUNGSNEIGUNGDie Daumlmpfungsneigung des Audiosignals auf der Basis der Verringerung auswaumlhlen die man erreichen moumlchte Je houmlher die Daumlmpfungsneigung bei gleicher Schnittfrequenz desto groumlszliger ist die Signalauswahl Man kann folgendes waumlhlen
12 entsprechend 12 dboct
24 entsprechend 24 dboct
48 entsprechend 48 dboct
d) SCHNITTFREQUENZErlaubt die Durchgangsfrequenz der niederen Frequenzen (Bassdurchgangsfilter) oder der hohen Frequenzen (Hochdruchgangsfilter) einzustellenDie Auswahl des Schnitts bezieht sich auf die Wiedergabe die man erreichen moumlchteDie benutzte Maszligeinheit ist Hz
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
BESCHREIBUNG DES MENUumlFENSTERS Matrix
Erlaubt fuumlr jeden Ausgang das Eingangssignal zu waumlhlen das als Quelle benutzt werden soll
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) AUSGANGSKANAumlLEIdentifizierung des einzustellenden Ausgangskanals
b) IDENTIFIZIERUNG DER EINGAumlNGEDen Signaltyp auswaumlhlen der nach eigener Anforderung jedem einzelnen Ausgang zugeordnet werden soll Man kann folgendes waumlhlen
In A Das Signal wird dem Eingang A zugeordnet
In B Das Signal wird dem Eingang B zugeordnet
In A+B Zuordnung der a lgebra ischen Summe der be iden Eingangssignale A und B
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
BESCHREIBUNG DES MENUumlFENSTERS Option
Erlaubt die Anzeige der Systemeinstellungen wie die Zuordnung der Ein- und Ausgaumlnge Daumlmpfung Displaykontrast und Firmware-Version
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B Src
Diese Option erlaubt die Einstellung des Audio-Signaltyps am Eingang
Analoge Audiosignale (Eingaumlnge A und B)
Digitale Audiosignale (Eingang AESEBU)
DigOut Src
An In =Audiosignale an den analogen Eingaumlngen
Dig In =Audiosignale am digitalen Eingang
OUT 1-2 =Audiosignale an den Ausgaumlngen 1 und 2
OUT 3-4 =Audiosignale an den Ausgaumlngen 3 und 4
OUT 5-6 =Audiosignale an den Ausgaumlngen 5 und 6
Input Mode
An In
Dig In
Indip =
Linked =
Diese Option erlaubt die Audioquelle zu waumlhlen die fuumlr den Steckverbinder AESEBU OUT (digitaler Ausgang) bestimmt ist
Erlaubt die Eingaumlnge zu konfigurieren
Sie sind unabhaumlngig und selbststaumlndig sie unterliegen keinen Verpflichtungen untereinander Sie sind verbunden und funktionieren im Stereo-Modus
Die Kompressoren Filter Verzoumlgerungen die Lautstaumlrke sind bei beiden Kanaumllen identisch
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
39
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
40
Atten PadZeigt an wie der Wahlschalter -6 dB auf der Ruumlckseite eingestellt ist [Ref 5] Dieser Wahlschalter muss aktiviert werden wenn das Level an den analogen Eingaumlngen zu hoch ist Der Wahlschalter wird uumlber die Taste aktiviert im Menuuml gibt es nur eine Anzeige
0dB = Wahlschalter nicht aktiviert
-6dB = Wahlschalter aktiviert
Contrast
10 heller 60 dunkler 100
Fw Vers
Die Eingangssignale sind dieselben wie die Eingangsquelle
Die Eingangssignale werden vom internen Prozessor um -6 dB gedaumlmpft
Erlaubt den Kontrast des LCD-Displays einzustellen um den Unterschied der Helligkeit auf den Installationsort auszurichten Ein deutlicheres Display erlaubt auf korrekte und schnelle Weise innerhalb der Menuumls zu surfenDie Hersteller-Einstellung am Ausgang liegt bei 60
Zeigt die Firmware-Version des Prozessors an
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
41
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
42
TECHNISCHE DATEN
Antwort in FrequenzDynamische GammaCMMRCrosstalkDistorsion
ProzessorFrequenz der DatenausarbeitungAnaloge Converter Verzoumlgerung der VerteilungSpeicherung der Konfigurationen
DisplayTastenBedienungen
Analoger Eingang ndeg2 x XLR (3-poliger Female Stecker)Impedanz des Eingangs gt10KOhmMaximales Level +21dBu ohne PAD
+27dBu bei PAD
Impedanz des Ausgangs 50OhmMaximales Level +21dBu Typ symmetrisch
Typ SPDIF-AESEBU (AES3)
Typ Entsprechend dem Standard des Eingang
Typ
Typ
NETZSPANNUNGABMESSUNGEN (BXHXT)GEWICHT
AUDIO-LEISTUNGEN+- 01dB (20 to 30kHz)116dB typgt 60dB (50 to 10kHz)lt -100dB0002 (1kHz +4dBu)
DIGITALE AUDIO-LEISTUNGEN DSP 2856-bit 48KHz24-bit BURR BROWN15ms32 preset
KONTROLLEN LCD GrafikESC - MENU - FUNCTIONS SELECTIONENTER
EIN-AUSGAumlNGE
Analoger Ausgang ndeg6 x XLR (3-poliger Male Stecker)
Digitaler Eingang ndeg1x XLR (3-poliger female Stecker)
Digitaler Ausgang ndeg1x XLR (3-poliger Male Stecker)
Ein-Ausgang Rdnet ndeg2 x XLR RJ45 (kabel CAT 5) USB Typ B
KONTROLLPARAMETER AUDIOStaumlrke -80dB a +20dB step 01dBVerzoumlgerung Eingang 0 a 729mS step 01 mS
Ausgang 0 a 340mS step 01mSPhasenrotation 0deg - 180deg
KOMPRESSIONSchwelle -80dB a +20dB step 01dBVerhaumlltnis 11 a Inf1 step 001Staumlrke am Ausgang 0dB a 40dB step 01dBAnschlusszeit 1mS a 1000mS step 01mSReleasezeit 1mS a 1000mS step 01mSBeibehaltungszeit 1mS a 1000mS step 01mS
EQUALIZER12 Equalizer fuumlr jeden Ein- und Ausgang
PEQ (parametrischer) Hi-shelf Lo-sheftFrequenz 20Hz a 20KHz step 1HzStaumlrke -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (lediglich PEQ)
FILTER CROSSOVERFilter Linkwitz Riley
HP HochdurchgangsfilterLP Bassdurchgangsfilter
Neigung 12dBoct - 24dBoct - 48dBoctSchnittfrequenz 5Hz a 20KHz step 1Hz
Full-range 100-240Vac 50-60Hz430482x43x130mm 19Kg
AnmerkungenSpezifikationen unterliegen Aumlnderungen ohne Vorankuumlndigung
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
INTRODUCTIONAC26N est un processeur audio numeacuterique pour la gestion de leacutequipement audio conccedilu pour des installations fixes et mobiles Il fonctionne selon une technologie de pointe avec des processeurs agrave 2856bits et des convertisseurs ADDA agrave 24-bits hautes performances Les fonctions du processeur sont les niveaux dentreacutee et de sortie le deacutelai (delay) la polariteacute 12 bandes deacutegalisation par canal dentreacutee et de sortie diffeacuterentes seacutelections de croisement (crossover) et un limiteur hautes performances Le controcircle des filtres a une reacutesolution de 1Hz Les entreacutees et les sorties peuvent ecirctre programmeacutees en plusieurs configurations pour satisfaire tous les besoins AC26N peut ecirctre controcircleacute en temps reacuteel et tous les paramegravetres peuvent ecirctre configureacutes depuis le pupitre frontale et par ordinateur avec interface graphique intuitive accessible via le logiciel laquoDVA Networkraquo et une connexion de reacuteseau deacutedieacutee RDnet ou USBLa mise agrave jour du logiciel pour lUniteacute centrale et DSP par ordinateur portable permet de maintenir le dispositif actualiseacute Il est possible denregistrer et de rappeler 32 configurations preacute-eacutequipeacutees de configuration
Contenu de lemballage - AC26N - Mode demploi- CD logiciel- Cacircble dalimentation
Caracteacuteristiques- 2 entreacutees et 6 sorties avec adressage flexible- Entreacutee et sortie steacutereacuteo AESEBU adressables - DSP 2856-bit- Convertisseurs AD BURR BWOWN 24-bit hautes performances- Freacutequence de reacutesolution des filtres 1 Hz - 12 eacutegaliseurs parameacutetriques pour chaque entreacutee et sortie- 2 filtres de croisement par sortie avec pente seacutelectionnable agrave 122448dBoct- DRC agrave configuration multiple hautes performances pour configuration limiteur
compression pour chaque entreacutee et sortie- Niveau reacuteglable en dB polariteacute et deacutelai pour chaque entreacutee et sortie- Mise agrave jour du micrologiciel par lordinateur- Affichage graphique agrave cristaux liquides- 32 preacutereacuteglages enregistrables par lutilisateur- Interface USB pour le controcircle et la configuration par ordinateur- Interface RDnet permettant de controcircler jusquagrave 256 dispositifs agrave distance
PC
PC
RDNETcontrol(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FONCTIONS DE LA FACE AVANT
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
COMMANDES ET FONCTIONS1) AFFICHAGE
Laffichage graphique agrave cristaux liquides permet de visualiser et deacutediter les informations de lAC26N sans utiliser lordinateur Le contraste peut ecirctre configureacute dans le menu principal
2) MANETTE Functions Selector et Push EnterCe controcircle permet de se deacuteplacer de seacutelectionner et de modifier les paramegravetres dans les menus affichables agrave leacutecranRotation de la manette (Functions Selectors)- permet de se deacuteplacer sur les diffeacuterentes pages du menu - permet de modifier les paramegravetres seacutelectionneacutesPression de la manette (Push Enter)- permet de seacutelectionnervalider les paramegravetres
3) Bouton ESC Ce controcircle permet de quitter les menus afficheacutes ou de revenir agrave la visualisation preacuteceacutedente
4) Bouton Menu Ce controcircle permet dacceacuteder directement au menu principal
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
Fra
nccedilais
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
43
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
Fra
nccedilais
44
DVA Network
AC26N est eacutequipeacute dune interface de reacuteseau proprieacutetaire deacutenommeacutee RDNET au moyen de laquelle il est possible de sinterfacer agrave lordinateur agrave travers un peacuteripheacuterique (RDNET control)
Pour cela un protocole de communication a eacuteteacute deacuteveloppeacute avec lequel il est possible de recevoir et denvoyer les donneacutees ce branchement permet de faire le monitorage en temps reacuteel des paramegravetres du diffuseur comme puissance de sortie tempeacuterature de lamplificateur eacutetat du limiteur etc Il est aussi possible de seacutelectionner diffeacuterentes eacutegalisations ou den creacuteer de nouvelles et de reacutegler les niveaux de volume souhaiteacutes au moyen dun plug-in approprieacute
On conseille de teacuteleacutecharger gratuitement le logiciel DVA Network directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
DVA USB Manager
On conseille de teacuteleacutecharger gratuitement le logiciel DVA USB Manager directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
Le micrologiciel du module amplificateur peut ecirctre remis agrave jour par le port USBPour rendre cette mise agrave jour possible et facile un programme speacutecifique a eacuteteacute deacuteveloppeacute
DOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
CONNEXIONS DU PANNEAU ARRIEgraveRE
1586 75 141210 11 13 169 17
14) Connecteur ldquo USBrdquoCe connecteur USB (type B) permet de connecter le processeur agrave un ordinateur pour le controcircle et la mise agrave jour du micrologiciel via un programme deacutedieacute (DVA Network)
15) PRISE DALIMENTATION MAINSPermet la connexion du cacircble dalimentation fourni de seacuterie
16) PORTE-FUSIBLE FUSELogement pour fusible de ligne
17) INTERRUPTEUR GENERAL POWERLinterrupteur permet de mettre en marche ou deacuteteindre le controcircleur audio
COMMANDES ET FONCTIONS
5) SELECTEUR ldquo-6dBrdquoLe seacutelecteur permet de reacuteduire de 6dB les niveaux dentreacutee analogiques XLR [6] tout en compensant les niveaux eacuteleveacutes de sortie des meacutelangeurs ou dautres dispositifs audio Quand la barre du niveau de signal des entreacutees sur laffichage [1] reste au maximum cela indique que le niveau du signal entrant est eacuteleveacute Il est alors conseilleacute dutiliser latteacutenuation -6dBIl est possible de veacuterifier quand le seacutelecteur est activeacute par le menu Option
6) CONNECTEURS DENTREE ldquoArdquo ET ldquoBrdquoEntreacutees eacutequilibreacutees au niveau de la ligneIls sont en mesure daccepter des connecteurs XLR macircles
7) CONNECTEURS DE SORTIE ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo ET ldquo6rdquoSorties eacutequilibreacutees au niveau de la ligne Ils sont en mesure daccepter des connecteurs XLR femelles
Prendre garde agrave brancher convenablement les sorties sur les diffuseurs ou les amplificateurs en fonction des configurations de chaque canal pour eacuteviter des deacutegacircts et des problegravemes de fonctionnement
Section ldquoAESEBUrdquo
8) CONNECTEUR DENTREE INOutre les entreacutees audio analogiques une entreacutee audio numeacuterique SPDIF-AESEBU (AES3) a eacuteteacute preacutevue et peut ecirctre seacutelectionneacutee par le menu de setupLentreacutee requiert une connexion eacutequilibreacutee en utilisant un connecteur XLR avec un cacircble agrave 3 conducteurs de 110ohm torsadeacute
9) CONNECTEUR DE SORTIE OUTCe connecteur permet de relancer le signal audio dans les entreacutees analogiques ou numeacuteriques ou sur les sorties La source doit ecirctre reacutegleacutee par le menu OptionLa connexion sera conforme agrave la mecircme norme que lentreacutee [reacutef8]
Section ldquoRDNETrdquo
10) CONNECTEUR DENTREE DATA INPUTConnecteur RJ45 entreacutee de donneacutees
11) CONNECTEUR DE SORTIE DATA LINKConnecteur RJ45 sortie de donneacutees pour la connexion de seacuterie en cascade
12) VOYANT LUMINEUX ONCe voyant de couleur verte sallume uniquement quand lAC26N a reconnu et est connecteacute agrave luniteacute principale RDNET par lordinateur
13) VOYANT LUMINEUX ACTIVECe voyant de couleur jaune clignote quand une transmission des donneacutees est active entre RDNET et le dispositif
PUSH
P SHU
SHPU
P SHU
PUSH
CONNEXIONS
Audio analogiquesLes connexions eacutequilibreacutees permettent de reacuteduire au minimum le bruit provoqueacute par les cacircbles et dutiliser de longs cacircblesCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLe connecteur XLR doit ecirctre brancheacute avec la broche 1 agrave la masse la broche 2 au chaud (+) et la broche 3 au froid (-) En cas de cacircble blindeacute brancher le blindage agrave la broche 1Les cacircbles de connexion XLR-XLR et XLR-Jack14(63mm) peuvent semployer pour la connexion agrave lAC26N
12
3
Entreacutee
Entreacutee
XLR - femme
XLR - femme
1 2
3
Sortie
Sortie
XLR - Macircle
XLR - Macircle
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2 = Point chaudPhase +VE
Broche 3 =Point froidPhase -VE
Broche 3 =Point froidPhase -VE
Anneau
Manchon
Pointe Point chaudPhase +VE
Anneau = Point froidPhase -VE
ManchonB Masselindeacute
Pointe
Les connexions deacuteseacutequilibreacutees peuvent semployer mecircme si le bruit provoqueacute par les cacircbles augmente Les cacircbles ne peuvent deacutepasser 5m de longCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLes connexions deacuteseacutequilibreacutees peuvent abaisser le niveau du signal entrant de 6dB Pour remeacutedier agrave cet inconveacutenient il faut brancher la broche 3 agrave la masse mecircme si cela augmente le bruit
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
45
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
46
12
3
1 2
3
Pointe Manchon
Pointe = Signal
Broche 3 = Link to Pin 1
Broche 3 = Link to Pin 1
ManchonB Masselindeacute
Audio numeacuteriques (AESEBU)
AESEBU (protocole AES3) est une entreacutee eacutequilibreacutee isoleacutee eacutelectriquement agrave laide dun transformateur Elle permet demployer deux canaux audio dans un seul cacircble bipolaire blindeacute Les caracteacuteristiques du cacircble doivent ecirctre de 3 pocircles impeacutedance 100ohm torsadeacute et blindeacute avec connecteur XLR (AES3 standard)
RJ 45
|1|2|3|4|5|6|7|8|
RDnet
Chaque port RDNet des Control 2 et Control 8 peut ecirctre brancheacute agrave un maximum de 32 dispositifs compatibles placeacutes en cascade Dans lexemple suivant le port de luniteacute de controcircle RDNET CONTROL 2 est relieacute agrave lentreacutee DATA INPUT dun AC26N dont la sortie parallegravele DATA LINK est envoyeacutee agrave lentreacutee de lAC26N successif Dans lexemple [n] est un nombre compris entre 3 et 32 (limite maximale des dispositifs que lon peut relier agrave un sous-reacuteseau)
La longueur totale du cacircble CAT5 dun sous-reacuteseau NE peut PAS deacutepasser 900 megravetres
Le connecteur doit ecirctre relieacute comme 1 ndash disponible pour dautres fonctions (par exemple audio +) 2 ndash disponible pour dautres fonctions (par exemple audio )3 ndash disponible pour dautres fonctions (par exemple masse analogique)4 ndash masse numeacuterique5 ndash masse numeacuterique6 ndash disponible pour dautres fonctions (par exemple alimentation)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
MISE EN MARCHE
Lors de la mise en marche du dispositif linitialisation deacutebute et dure quelques secondes Leacutecran affiche le modegravele le logo et la barre de progression du chargement du programme
En fin de processus dinstallation leacutecran affiche la fenecirctre du menu Meters Pour connaicirctre les indications en deacutetail consulter le paragraphe DESCRIPTION FENETRE MENU Meters
LAC26N est precirct agrave lemploi
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION ET VISUALISATION
Pour entrer dans la fenecirctre du menu principal il faut pousser sur la touche MENU ( ) agrave lavant du dispositifDune page quelconque du menu en poussant sur la touche ESCrdquo ( ) on revient automatiquement sur la page-eacutecran preacuteceacutedente
MENU PRINCIPAL
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Le processeur contient six menus Ils montrent etou configurent les paramegravetres du systegravemeLes menus principaux sont
Meters Visualisation des niveaux des entreacutees et des sorties visualisation du programme utiliseacute et eacutetat mute rapide
Preset Meacutemoriser enregistrer et eacuteliminer les configurations du systegraveme
Matrix seacutelectionner les sorties en fonction du signal entrant
Ch Job configuration de chaque signal
X-Over configurer les freacutequences de coupure et les types de filtres pour chaque sortie
Option attribution des entreacutees et des sorties contraste daffichage la version du micrologiciel les entreacutees et dautres options
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
47
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
48
DESCRIPTION DE LA FENETRE MENU Metersrdquo
Cette fenecirctre permet de visualiser les configurations et leacutetat geacuteneacuteral des entreacutees et des sorties la version du programme utiliseacute son eacutetat et le mode de pilotage du systegraveme
Les menus et les options afficheacutees peuvent se seacutelectionner en tournant la manette ldquoFUNCTIONS SETECTORrdquo ( ) Pour avoir accegraves agrave linteacuterieur de la seacutelection il faut mettre le paramegravetre souhaiteacute en eacutevidence et pousser sur la manette ldquoPush Enterrdquo ( | ) Il faut en faire de mecircme pour seacutelectionner etou modifier les options dans les commandes du menu
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositifAvec des signaux dentreacutee numeacuteriques les indications ldquoArdquo et ldquoBrdquo correspondent agrave lentreacuteeEn tournant la manette ldquoFUNCTIONS SELECTORrdquo [2] on fait deacutefiler en mode cyclique les canaux dentreacutee de sortie et lindication de mute geacuteneacuteral (d) le canal seacutelectionneacute est mis en eacutevidence
b) BARRE DE NIVEAU DE COMPRESSIONMUTE CANAL
COMPRESSION DE SIGNALLa compression du signal est visualiseacutee par le deacutefilement de la barre de droite de haut en bas
MUTE Chaque canal peut ecirctre placeacute en mute Seacutelectionner le canal et pousser sur la manette ldquoPush Enterrdquo [2] pour valider le changement deacutetat Lindication du canal sera remplaceacutee par la lettre M et la barre sera totalement mise en eacutevidencePour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterations
c) BARRE DE NIVEAU DE SIGNALLindication du niveau de chaque canal est signaleacutee par le deacutefilement de la barre de gauche
d) MUTE GENERALIl est possible de mettre simultaneacutement toutes les entreacutees et les sorties en mute Tourner la manette ldquoFUNCTIONS SELECTORrdquo seacutelectionner la lettre M et pousser sur la manette Push EnterPour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterationsLe mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) MODES DE COMMANDEIl affiche le mode dutilisation etou les dispositifs qui sont relieacutes agrave lAC26N
Local = utilisation autonome Aucune connexion agrave un dispositif exteacuterieur
NET = relieacute directement au reacuteseau deacutedieacute RDNet et agrave lordinateur
USB = relieacute directement agrave un ordinateur par cacircble USB
f) INDICATION DETAT DE PARAMETRAGECette indication permet de constater si un ou plusieurs paramegravetre(s) du programme chargeacute aont eacuteteacute modifieacute(s) par rapport au dernier sauvetage
= programme dorigine
= programme avec des paramegravetres modifieacutes
g) PROGRAMME CONFIGURELe chiffre indique le programme chargeacute et utiliseacute par le systegraveme agrave lemplacement de sauvetage Consulter le menu de Preset pour de plus amples deacutetails
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
DESCRIPTION DE LA FENETRE MENU Ch Job
Cette fenecirctre permet dafficher la configuration de chaque canal
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) NIVEAU DU SIGNALIndique le gain du signal Laugmentation de lintensiteacute dun signal est libelleacutee en deacutecibel (dB) Le paramegravetre peut ecirctre seacutelectionneacute de -8000dB agrave +2000dB avec des pas de 001dB Une augmentation de 6dB est eacutegale approximativement au redoublement agrave leacutechelle lineacuteaire du niveau du signal sous tensionAvec un gain supeacuterieur agrave 0dB le signal est amplifieacute tandis quavec un gain infeacuterieur agrave 0dB le signal est atteacutenueacute
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
49
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
50
c) DELAI DU SIGNAL (DELAY)Le signal audio reproduit peut ecirctre retardeacute pour permettre lalignement acoustique Cela compense les diffeacuterentes positions des diffuseurs pendant linstallation et la reproduction sonore Il se libelle en mS Le paramegravetre peut ecirctre seacutelectionneacute de 00mS agrave 729mS avec un pas de 01mSPour aligner un signal audio il est possible dutiliser la formule suivante
Deacutelai = (GAPx1000)344
Deacutelai = ms (en millisecondes)GAP = distance du diffuseur du point de reacutefeacuterence (en megravetres)Vitesse du son = 344ms
d) MUTEChaque canal peut ecirctre placeacute en mute La mecircme commande peut ecirctre activeacutee dans la fenecirctre du menu meters NB Le mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) PhasePermet la rotation de phase de 180deg par rapport au signal entrantCette rotation permet loptimisation surtout des basses freacutequences dans les installations complexes
f) EGALISATIONCette commande ouvre la fenecirctre du menu deacutegalisation de chaque canal Elle sert surtout pour corriger une ou plusieurs freacutequences qui doivent ecirctre atteacutenueacutees ou augmenteacutees
M M
LAC26N gegravere 12 filtres par canal dentreacutee et sortie avec trois types de configurations diffeacuterentes - Leacutegaliseur PEQ (peaking equalizer) est ideacuteal pour identifier isoler et
corriger une seule plage de freacutequences bien deacutetermineacutee Toutes les freacutequences passent mais il augmente ou diminue uniquement celles autour de la freacutequence centrale pour une bande preacutecise et un gain deacutefini
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessus de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessous de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
f Numeacuterotation des 12 filtres disponibles pour cette entreacutee ou cette sortie1
f Le type de filtre est afficheacute 2
Dis Deacutesactiveacute (absent)
PEQ Peaking equlizer
Sh H Filtre high-shelf
Sh L Filtre high-shelf
Exemples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
REMARQUELe paramegravetre Bw deacutetermine le champ de freacutequences adjacent agrave la freacutequence configureacutee ougrave est activeacute le filtre Plus la valeur Bw est eacuteleveacutee plus vaste est le champ de freacutequences (1Bw=1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONCette commande ouvre la fenecirctre du menu de compression de chaque canal
g1) TresholdIdentifie le seuil ougrave commence le rapport de compression La valeur de base 11
g2) RatioIndique le rapport de conversion entre le signal entrant et le signal sortant
g3) Post Gain Attach Release HoldCes donneacutees deacutependent du rapport de conversion que lon veut obtenir - Post Gain est le gain de sortie- Attack est le temps dattaque - Release est le temps de relacircchement- Hold est le temps de maintien
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
52
DESCRIPTION DE LA FENETRE MENU Preset
Cette fenecirctre permet de meacutemoriser jusquagrave 32 configurations dans lAC26NLe fabricant fournit le systegraveme avec un programme configureacute et enregistreacute en position 0 et non susceptible deacutecrasement
032 Elle indique lemplacement de sauvetage de la configurationCe numeacutero apparaicirct dans la fenecirctre Meters en position (g) A tout moment le programme utiliseacute peut ecirctre afficheacute par lutilisateur
Empty Preset Cest le nom qui est associeacute au numeacutero de lemplacement quand aucune configuration (vide) nest enregistreacutee
Local preset Local preset est le nom qui est associeacute au numeacutero de lemplacement quand on enregistre une configuration NB = Il est possible denregistrer une configuration avec lenom souhaiteacute de 16 lettres tout au plus agrave condition que lonutilise linterface via lordinateur
Le nom du programme assigneacute est indiqueacutePour toucher agrave lapplication 3 choix soffrent agrave vous
Save Le programme est enregistreacute en meacutemoire de lAC26N
Del Le programme est effaceacute
Load Le programme est chargeacute et precirct agrave lemploi
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
51
DESCRIPTION DE LA FENETRE MENU X-Over
Cette fenecirctre permet de seacutelectionner un filtre passe bas un filtre passe haut ou par la combinaison des deux de creacuteer un filtre passe bande pour chaque sortieLe filtre actif est un Linkwitz-Riley qui permet de seacutelectionner la pente de 12dBoct 24dBoct ou 48dBoct et sa freacutequence de coupure
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) CANAUX DE SORTIE
Les connecteurs de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) FILTRE CROSSOVERSeacutelectionner le filtre selon les besoins Il est possible de seacutelectionner
Dis Aucun filtre activeacute
HP Filtre passe-haut laisse passer uniquement la partie de signal audio supeacuterieure agrave la freacutequence de coupure
LP Filtre passe-bas laisse passer uniquement la partie de signal audio infeacuterieure agrave la freacutequence de coupure
Configuration du filtre Passe-haut Passe-bas
Rien Dis Dis
Passe-haut HP Dis
Passe-bas Dis LP
Passe-bande HP LP
12dBoct
24dBoct
Hz
dB
Ga
in 48dBoct
12dBoct
24dBoct
Hz
dB
Ga
in
48dBoct
c) PENTE DATTENUATIONSeacutelectionner la pente datteacutenuation du signal audio en fonction de la diminution que lon veut obtenir Plus la pente datteacutenuation est eacuteleveacutee agrave eacutegaliteacute de freacutequence de coupure plus eacuteleveacutee sera la seacutelection du signal Il est possible de seacutelectionner
12 correspond agrave 12dboct
24 correspond agrave 24dboct
48 correspond agrave 48dboct
d) FREQUENCE DE COUPUREElle permet de reacutegler la freacutequence de passage des freacutequences infeacuterieures (filtre passe-bas) ou des freacutequences supeacuterieures (filtre passe-haut) uniquementLe choix de la coupure deacutepend de la reproduction que lon veut obtenirLuniteacute de mesure utiliseacutee est lHz
Hz
Hz
dB
dB
Ga
in
f0
f0
0dB0dB
0dB
-6dB
freacutequence
freacutequence
freacutequence
freacutequence
Ga
in
f0
0dB
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
53
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
54
DESCRIPTION DE LA FENETRE MENU Matrix
Elle permet de seacutelectionner le signal entrant agrave utiliser comme source pour chaque sortie
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) CANAUX DE SORTIEIdentification du canal sortant agrave reacutegler
b) IDENTIFICATIONS DES ENTREESSeacutelectionner le type de signal agrave associer agrave chaque sortie en fonction des besoins Il est possible de seacutelectionner
In A Le signal entrant A est associeacute
In B Le signal entrant B est associeacute
In A+B La somme algeacutebrique des deux signaux entrants A et B est associeacutee
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
DESCRIPTION DE LA FENETRE MENU Option
Permet dafficher les reacuteglages du systegraveme comme lassignation des entreacutees et des sorties latteacutenuation le contraste de laffichage et la version du logiciel
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcCette option permet de reacutegler le type de signal audio entrant
An In =signaux audio analogiques (entreacutees ldquoArdquo et ldquoBrdquo)
Dig In =signaux audio numeacuteriques (entreacutee AESEBU)
DigOut SrcCette option permet de seacutelectionner la source audio qui sera adresseacutee sur le connecteur AESEBU OUT (sortie numeacuterique)
An In = signaux audio des entreacutees analogiques
Dig In =signaux audio sur lentreacutee numeacuterique
OUT 1-2 = signaux audio sur les sorties 1 et 2
OUT 3-4 = signaux audio sur les sorties 3 et 4
OUT 5-6 = signaux audio sur les sorties 5 et 6
Input ModePermet de configurer les entreacutees
Indip = sont indeacutependantes et autonomes Ne sont soumises agrave aucun type de lien
Linked = sont unies et fonctionnent en mode steacutereacuteo Les compresseurs les filtres les deacutelais le volume sont identiques pour les deux canaux
Atten PadIndique le mode de reacuteglage du seacutelecteur ldquo-6dBrdquo placeacute agrave larriegravere [reacutef 5] Il faut activer ce seacutelecteur quand les niveaux dentreacutee analogiques sont trop eacuteleveacutes Le seacutelecteur sactive uniquement par le bouton Dans le menu il sagit dune simple visualisation
0dB = seacutelecteur non activeacute Les signaux dentreacutee sont identiques agrave la source entrante
-6dB = seacutelecteur activeacute Les signaux entrants sont atteacutenueacutes de -6dB par le processeur interne
ContrastIl permet de reacutegler le contraste de laffichage agrave cristaux liquides pour compenser la diffeacuterence de luminositeacute avec le lieu dinstallation Une plus grande clarteacute de laffichage permet de naviguer convenablement et rapidement dans les menusLe reacuteglage agrave la sortie de lusine du fabricant est de 60
10 plus clair 60 plus fonceacute 100
Fw VersIndique la version du logiciel du processeur
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
55
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
56
DONNES TECHINIQUES
PERFORMANCES AUDIOReacuteponse en freacutequence +- 01dB (20 to 30kHz)Plage dynamique 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsion 0002 (1kHz +4dBu)
PERFORMANCES AUDIO NUMERIQUES Processeur DSP 2856-bit Freacutequence de traitement des donneacutees 48KHzConvertisseurs analogiques 24-bit BURR BROWNDeacutelai de propagation 15msMeacutemorisations des configurations 32 preset
CONTROLES Affichage LCD graficoBoutonsCommandes ESC - MENU - FUNCTIONS SELECTION
ENTERENTREESSORTIESEntreacutee analogique ndeg2 x XLR (3 broches femelle)
Impeacutedance dentreacutee gt10KOhmNiveau maximum +21dBu senza PAD
+27dBu con PADSortie analogique ndeg6 x XLR (3 broches macircle )
Impeacutedance de sortie 50OhmNiveau maximum +21dBuType Balanceacute
Entreacutee numeacuterique ndeg1x XLR (3 broches femelle)Type SPDIF-AESEBU (AES3)
Sortie numeacuterique ndeg1x XLR (3 broches macircle )Type conforme agrave la norme de lentreacutee
EntreacuteesSortie Rdnet ndeg2 x XLR RJ45 (cacircble CAT 5)USB Type B
PARAMETRES DE CONTROLE DU SONGain -80dB a +20dB eacutetape 01dBDeacutelai Entreacutee 0 a 729mS eacutetape 01 mS
Sortie 0 a 340mS eacutetape 01mSRotation de phase 0deg - 180deg
COMPRESSIONSeuil -80dB a +20dB eacutetape 01dBRapport 11 a Inf1 eacutetape 001Gain agrave la sortie 0dB a 40dB eacutetape 01dBTemps dattaque 1mS a 1000mS eacutetape 01mSTemps de relacircchement 1mS a 1000mS eacutetape 01mSTemps de maintien 1mS a 1000mS eacutetape 01mS
EGALISEURS12 eacutegaliseurs pour chaque entreacutee et sortieType PEQ (parameacutetrique) Hi-shelf Lo-sheft
Freacutequence 20Hz a 20KHz eacutetape 1HzGain -30dB a +15dB eacutetape 001dBBande 005dB a 2dB eacutetape 001dB (uniquement pour PEQ)
FILTRES CROSSOVERFiltre Linkwitz Riley
Type HF high-shelfLF low-shelf
Pente 12dBoct - 24dBoct - 48dBoctFreacutequence de coupure 5Hz a 20KHz eacutetape 1Hz
ALIMENTATION Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)POIDS 19Kg
Remarques Speacutecifications sujettes agrave modifications sans preacuteavis
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
2 VIE ATTIVO2 WAY ACTIVE
3 VIE PASSIVO3 WAY PASSIVE
L
L
A
A
HIGH L
MID L
LOW HIGHMID RHIGHMID L
LOW L
HIGH R
MID R
LOW R
R
R
B
B
1
1
2
2
3
3
456
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
Menu Matrix configurationMatrix
57 58
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
EROUIG ATRIX TNM
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
OU
TP
UT
1
OU
TP
UT
2
OU
TP
UT
3
OU
TP
UT
4
OU
TP
UT
5
OU
TP
UT
6
AE
S-E
BU
OU
TP
UT
INP
UT
A
AE
S-E
BU
INP
UT
INP
UT
B
D D D D D D
D D
A A A A A A
A SA
MP
LE
RA
TE
CO
NV
A
LIN
KA
BL
E
SC
HE
MA
A B
LO
CC
HI -
BL
OC
K D
IAG
RA
MB
LO
CK
SC
HA
LT
BIL
D -
SC
HE
MA
S F
ON
CT
ION
NE
LS
LINE ARRAY SUB MONO ATTIVO
LINE ARRAY SUB MONO ACTIVEINGRESSI - INPUT
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
L
L
L
A
A
A
AESEBU IN
AESEBU IN
AESEBU IN
AESEBU OUT
AESEBU IN
AESEBU IN
AESEBU OUT
R
R
R
LR
B
B
B
123456
HIGHMID L
HIGHMID L HIGHMID R
HIGHMID R
LOW L LOW R
LAYER
DISPLAY MEMORY
FADER MODE
LAYER
DISPLAY MEMORY
FADER MODE
Ingresso ANALOGICO
ANALOG Input
Collegamento in cascata
Link connections
Ingresso DIGITALE
DIGITAL inputA B
BALANCED AUDIO INPUTS
-6dB
PUSH PUSH
IN OUT
AES EBUPUSH
Oppure
or
Oppure
or
Menu Option configurationOption
Menu Option configurationOption Menu Option configurationOption
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type Analog
AES out An In
Input type Analog
AES out An In
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
59 60
InA-B Src Dig InInA-B Src Dig InInA-B Src An InInA-B Src An In
frequenzaHz
dB
Gu
ad
ag
no
60 200 2800
0dB0dB
-6dB
Esempio di un sistema a 3-vie
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
Out 1 Out 2 Out 3
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Esempio di un sistema a 3-vie
61 62
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
26NAC 26NAC
R TE
DO
R
MO LEU O R CE S
E O TR L A
S O
O C ND I P
P hsuernE t
o su cti nF nel rS e tc o
E CSME UN
IGCHTE OL SN EOBd
ocaL l
M
0
484
467
430
44
31
75
12
7
DIMENSIONI DIMENSIONSABMESSUNGEN DIMENSIONS
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
RUumlCKWANDANSCHLUumlSSE
1586 75 141210 11 13 169 17
14) USB-SteckverbinderDieser USB-Steckverbinder (Typ B) erlaubt den Prozessor an einem Computer anzuschlieszligen um die Firmware mit dem speziellen Programm (DVA Network) zu kontrollieren und zu aktualisieren
15) STROMANSCHLUSS MAINSErlaubt den Anschluss des mitgelieferten Versorgungskabels
16) SICHERUNGSTRAumlGER FUSEAufnahme fuumlr die Netz-Sicherung
17) HAUPTSCHALTER POWERDer Schalter erlaubt das Aus- und Einschalten des Audio-Controllers
BEDIENUNGEN UND FUNKTIONEN
5) WAHLSCHALTER -6dBDer Wahlschalter erlaubt das Level des analogen Eingangs XLR [6] um 6 dB zu verringern und gleichzeitig das hohe Ausgangslevel der Mixer oder anderer Audio-Vorrichtungen auszugleichen Wenn der Balken des Signallevels der Eingaumlnge auf dem Display [1] immer auf Maximum steht zeigt dies an dass das Signallevel am Eingang hoch ist und es wird empfohlen die Daumlmpfung -6dB zu benutzenIm Menuuml Option ist es moumlglich zu kontrollieren ob der Wahlschalter aktiviert ist
6) STECKVERBINDER AM EINGANG A UND BAuf Leitungslinie ausgeglichene EingaumlngeSie koumlnnen auch XLR-Steckdosen aufnehmen
7) AUSGANG-STECKVERBINDER ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo UND ldquo6rdquoAuf Leitungslinie ausgeglichene Ausgaumlnge Sie koumlnnen auch XLR-Stecker aufnehmen
Darauf achten dass die Ausgaumlnge korrekt entsprechend der Einstellungen der einzelnen Kanaumlle an den Lautsprechern oder Verstaumlrkern angeschlossen sind um Schaumlden und Fehlfunktionen vorzubeugen
Abschnitt ldquoAESEBUrdquo
8) EINGANGS-STECKVERBINDER INZusaumltzlich zu den analogen Audio-Eingaumlngen wurde ein digitaler Audio-Eingang SPDIF-AESEBU (AES3) vorgesehen der uumlber das Setup-Menuuml ausgewaumlhlt werden kannDer Eingang erfordert einen ausgeglichenen Anschluss mit einem XLR-Steckverbinder mit einem verdrillten Kabel mit 3 Leitern von 110 Ohm
9) AUSGANGS-STECKVERBINDER OUTDieser Steckverbinder erlaubt das Audiosignal an den analogen oder digitalen Eingaumlngen oder Ausgaumlngen zu verteilen Die Quelle muss uumlber das Menuuml Option eingestellt werdenDer Anschluss muss demselben Standard des Eingang entsprechen [Ref 8]
Abschnitt ldquoRDNETrdquo
10) EINGANGS-STECKVERBINDER DATA INPUTSteckverbinder RJ45 fuumlr den Dateneingang
11) AUSGANGS-STECKVERBINDER DATA LINKSteckverbinder RJ45 fuumlr den Datenausgang Fuumlr die serielle Kaskaden-Verbindung
12) LEUCHTANZEIGE ONDiese gruumlne Anzeige leuchtet nur wenn AC26N uumlber den Computer mit der Haupteinheit RDNET verbunden ist und diese erkannt hat
13) LEUCHTANZEIGE ACTIVEDiese gelbe Anzeige blinkt wenn eine Datenuumlbertragung zwischen RDNET und der Vorrichtung aktiv ist
PUSH
P SHU
SHPU
P SHU
PUSH
ANSCHLUumlSSE
Analoge Audio-AnschluumlsseDie ausgeglichenen Anschluumlsse erlauben die Geraumlusche der Kabel auf ein Minimum zu verringern und so die Benutzung langer Kabel zuzulassenDiese Anschluumlsse koumlnnen sowohl an den Ein- als auch an den Ausgaumlngen benutzt werdenDer XLR-Steckverbinder muss mit Pin 1 an Masse Pin 2 am Pluspol (+) und Pin 3 am Minuspol (-) angeschlossen werden Bei einem abgeschirmten Kabel muss die Abschirmung an Pin 1 liegenDie Verbindungskabel XLR-XLR und XLR-Jack 14 (63 mm) koumlnnen fuumlr den Anschluss
12
3
Eingang
XLR weiblichen
Pin 3 = MinuspolErkaumlltungphase -VE
Pin 3 = MinuspolErkaumlltungphase -VE
1 2
3
Ausgang
XLR maumlnnlichen
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 2 = PluspolWaumlrmephase +VE
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Pin 1 =SchirmMasse
Ring
Schaft
Spitze = PluspolWaumlrmephase +VE
Ring = MinuspolErkaumlltungphase -VE
Schaft=SchirmMasse
Spitze
Die nicht ausgeglichenen Anschluumlsse koumlnnen auch benutzt werden wenn die Kabelgeraumlusche ansteigen und diese Kabel duumlrfen nicht laumlnger sein als 5 MeterDiese Anschluumlsse koumlnnen sowohl an den Ein- als auch an den Ausgaumlngen benutzt werdenDie nicht ausgeglichenen Anschluumlsse koumlnnen das Signallevel am Eingang um 6 dB verringern um dem vorzubeugen muss Pin 3 an Masse angeschlossen werden obwohl dies das Geraumlusch verstaumlrken kann
12
3
Eingang
XLR weiblichen
1 2
3
Ausgang
XLR maumlnnlichen
Spitze Schaft
Spitze = Signal
Schaft=SchirmMasse
Pin 3 = zu Pin 1 gebruumlckt
Pin 3 = zu Pin 1 gebruumlckt
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
31
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
32
Digitales Audio (AESEBU)AESEBU (Protokoll AES3) ist ein ausgeglichener und uumlber einen Transformator elektrisch isolierter Eingang Er erlaubt die Benutzung von zwei Kanaumllen an einem einzigen abgeschirmten bipolaren Kabel Das gedrillte Kabel muss 3-polig sein eine Impedanz von 100 Ohm haben und mit einem XLR-Steckverbinder (AES3 Standard) abgeschirmt sein
RdnetJeder Port RDNet an Control 2 und Control 8 kann an max 32 kompatiblen Vorrichtungen die in Kaskade geschaltet sind angeschlossen werden Im nachstehenden Beispiel ist der Port der Kontrolleinheit RDNET CONTROL 2 am Eingang DATA INPUT eines AC 26N angeschlossen dessen paralleler Ausgang DATA LINK zum Eingang des naumlchsten AC26N geht Im Beispiel ist [n] eine Nummer zwischen 3 und 32 (maximale Anzahl der anschlieszligbaren Vorrichtungen an nur einem Netz)
RJ 45
|1|2|3|4|5|6|7|8|
Die Gesamtlaumlnge des Kabels CAT5 eines Unternetzes kann NICHT laumlnger als 900 Meter sein
Der Steckverbinder muss wie folgt angeschlossen sein1 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio +) 2 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio -)3 ndash Verfuumlgbar fuumlr andere Funktionen (zB analoge Masse)4 ndash digitale Masse5 ndash digitale Masse6 ndash Verfuumlgbar fuumlr andere Funktionen (zB Versorgung)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
EINSCHALTEN
Beim Einschalten der Vorrichtung startet die Initialisierung die einige Sekunden lang dauert Auf dem Display wird das Modell das Logo und der Fortschrittsbalken der Ladung des Programms angezeigt
Nach der Initialisierung erscheint auf dem Display das Menuumlfenster Meters Um die Angaben im Detail zu erfahren beziehen Sie sich bitte auf das Kapitel BESCHREIBUNG DES MENUumlFENSTERS Meters
AC26N kann jetzt benutzt werden
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
MENUrsquo PRINCIPALE
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Die sechs Menuumls im Prozessor zeigen undoder konfigurieren die Systemparameter
Anzeige der Levels der Ein- und Ausgaumlnge Anzeige des benutzten Programms und dessen Status Mute schnell
Speicherung Speicherung und Eliminierung der Systemkonfigurationen
Auswahl der Ausgaumlnge je nach Eingangssignal
Konfiguration jedes einzelnen Kanals
Konfiguration der Schnittfrequenzen und der Filtertypen fuumlr jeden einzelnen Ausgang
Zuordnung der Ein- und Ausgaumlnge Kontrast des Displays Firmware-Version Eingaumlnge und andere Optionen
Das Menuuml und die einzelnen Optionen der Anzeige koumlnnen durch Drehen des Drehgriffes FUNKTIONS SELECTOR ( ) ausgewaumlhlt werden
Die Hauptmenuumls sind
Meters
Preset
Matrix
Ch Job
X-Over
Option
Um die Auswahl zu treffen muss der gewuumlnschte Parameter auswaumlhlt und der Drehgriff Push Enter( | ) gedruumlckt werdenDas selbe Verfahren muss fuumlr die Auswahl undoder die Aumlnderung der Optionen innerhalb der Menuumlpunkte angewendet werden
BESCHREIBUNG DES MENUumlFENSTERS Meters
Diese Seite erlaubt die Konfigurationen und den allgemeinen Status der Ein- und Ausgaumlnge der benutzten Programmversion dessen Status und die Steuerung des Systems anzuzeigen
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
KONFIGURATION UND ANZEIGE
Um in das Fenster des Hauptmenuumls zu gelangen muss die Taste Menuuml ( ) auf der Frontseite der Vorrichtung gedruumlckt werdenMit der Taste ESC ( ) kehrt man von jeder Seite des Menuumls auf die vorherige Seite zuruumlck
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
33
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
34
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziertBei den digitalen Eingangssignalen entspricht die Angabe A und B dem EingangDreht man den Drehgriff FUNCTIONS SELECTOR [2] durchlaumluft man zyklisch die Ein- und Ausgangskanaumlle und die Angabe Mute allgemein (d) der ausgewaumlhlte Kanal wird hervorgehoben
b) BALKEN FUumlR DAS KOMPRESIONSLEVELMUTE KANAL
SIGNALKOMPRESSIONDie Signalkompression wird durch das Gleiten des rechten Balkens von oben nach unten angezeigt
MUTE Jeder einzelne Kanal kann auf Mute gestellt werden Den Kanal auswaumlhlen und den Drehgriff Push Enter [2] druumlcken um die Aumlnderung des Status zu bestaumltigen Die Angabe des Kanals wird durch den Buchstaben M ersetzt und der Balken wird komplett hervorgehobenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werden
c) BALKEN DES SIGNALLEVELSDie Anzeige des Levels jedes einzelnen Kanals wird durch das Gleiten des linken Balkens angezeigt
d) MUTE ALLGEMEINEs ist moumlglich alle Ein- und Ausgaumlnge gleichzeitig auf Mute zu schalten Den Drehgriff FUNCTIONS SELECTOR drehen den Buchstaben M waumlhlen und dann den Drehgriff Push Enter druumlckenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werdenDie allgemeine Stummschaltung hat eine houmlhere Prioritaumlt als die Stummschaltung der einzelnen Kanaumlle
e) ANSTEUERUNGSARTENEs wird angezeigt wie AC26N benutzt wird undoder an welchen Vorrichtungen es angeschlossen ist
= Benutzung stand-alone Kein Anschluss an einer externen Vorrichtung
= Direkt am Netz RDnet und am Computer angeschlossen
= Uumlber USB-Kabel direkt am Computer angeschlossen
f) ANZEIGE DES STATUS DER EINSTELLUNGENHier wird angezeigt ob einer oder mehrere Parameter des geladenen Programms im Vergleich zur letzten Speicherung veraumlndert wurden
Original-Programm
Programm mit veraumlnderten Parametern
g) EINGESTELLTES PROGRAMMDie Nummer zeigt das vom System geladene und benutzte Programm in Bezug auf die Lokalisierung der Speicherung an Fuumlr weitere Details beziehen Sie sich bitte auf das Menuuml Preset
Local
NET
USB
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
BESCHREIBUNG DES MENUumlFENSTERS Ch Job
Dieses Fenster erlaubt die Anzeige der Konfiguration jedes einzelnen Kanals
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) SIGNALLEVELZeigt die Signalstaumlrke an Das Ansteigen der Signalintensitaumlt wird in Dezibel (dB) ausgedruumlckt Der Parameter kann zwischen -8000 dB und +2000 dB in Schritten von 001 dB ausgewaumlhlt werden Ein Anstieg von 6 dB ist fast gleich eine Verdoppelung in linearer Skala des Spannungswertes des SignalsBei einer Staumlrke von 0 dB wird das Signal verstaumlrkt waumlhrend es ein einer Staumlrke von weniger als 0 dB abgeschwaumlcht wird
c) VERZOumlGERUNG DES SIGNALS (DELAY)Das wiedergegebene Audio-Signal kann verzoumlgert werden um die akustische Ausrichtung zu erlauben Dies gleicht die verschiedenen Positionen der Lautsprecher bei der Installation und Klangwiedergabe aus und wird in mS ausgedruumlckt Der Parameter kann zwischen 00 mS und 729 mS in Schritten von 01mS ausgewaumlhlt werden
Um ein Audiosignal auszurichten kann folgende Formel benutzt werden
Verzoumlgerung = GAPx1000)344
Verzoumlgerung = mS (in Millisekunden ausgedruumlckt)GAP = Abstand des Lautsprechers vom Referenzpunkt (in Metern ausgedruumlckt)Klanggeschwindigkeit = 344 ms
d) MUTEJeder einzelne Kanal kann auf Mute gestellt werden Derselbe Befehl kann im Fenster des Menuumls Meters aktiviert werden PS Die al lgemeine Stummschaltung hat eine houmlhere Priori taumlt als die Stummschaltung der einzelnen Kanaumlle
e) PHASEErlaubt die Phasenrotation um 180deg zum EingangssignalDiese Rotation erlaubt vor Allem die Optimierung der niederen Frequenzen bei komplexen Installationen
f) ENTZERRUNGENDieser Befehl oumlffnet das Menuumlfenster fuumlr die Entzerrung des einzelnen Kanals Er wird vor Allem benutzt um eine oder mehrere Frequenzen zu korrigieren die gedaumlmpft oder verstaumlrkt werden muumlssen
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
35
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
36
AC26N verwaltet 12 Filter fuumlr jeden einzelnen Ein- und Ausgangskanal mit drei verschiedenen Konfigurationen- Equalizer PEQ (peaking equalizer) ist ideal um nur ein bestimmtes Frequenzband
zu identifizieren zu isolieren und zu korrigieren Es gehen alle Frequenzen durch aber nur die um die mittlere Frequenz steigt und sinkt um eine bestimmte Bandbreite und eine bestimmte Staumlrke
- Equalizer High-Shelf geht alle Frequenzen durch aber die Frequenzen uumlber der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
- Equalizer Low-Shelf geht alle Frequenzen durch aber die Frequenzen unter der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
f Nummerierung der 12 verfuumlgbaren Filter fuumlr diesen Ein- oder Ausgang1
f2 Es wird der Filtertyp angezeigt
Dis Ausgeschaltet (nicht vorhanden)
PEQ Peaking equalizer
Sh H Filter High-Shelf
Sh L Filter Low-shelf
Beispiele PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
ANMERKUNGDer Parameter Bw legt das Frequenzfeld neben der eingestellten Frequenz fest wo der Filter aktiviert wird je houmlher der Bw-Wert desto houmlher das Frequenzfeld (1Bw=1 Oktave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filter High-Shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filter Low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) KOMPRESSIONDieser Befehl oumlffnet das Menuumlfenster fuumlr die Kompression des einzelnen Kanals
g1) TresholdIdentifiziert die Schwelle an der das Kompressionsverhaumlltnis beginnt Der Basiswert 11
g2) RatioIdentifiziert das Kompressionsverhaumlltnis zwischen dem Ein- und Ausgangssignal
g3) Post Gain Attach Release HoldDiese Daten entsprechen dem Kompressionsverhaumlltnis das man erreichen moumlchte
Post Gain ist der Gewinn am AusgangAttack ist die Anschlusszeit Release ist die ReleasezeitHold ist die Beibehaltungszeit
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
BESCHREIBUNG DES MENUumlFENSTERS Preset
Dieses Fenster erlaubt bis zu 32 Konfigurationen im AC26N zu speichernDer Hersteller liefert das System mit einem voreingestellten Programm das auf Position 0 gespeichert ist und nicht uumlberschrieben werden kann
032 Es zeigt die Lokalisierung der Speicherung der KonfigurationDiese Nummer erscheint auch im Fenster Meters auf der Position (g) Das benutzte Programm kann jederzeit vom Benutzer angezeigt werden
Empty Preset Es ist der Name der der Nummer der Lokalisierung zugeordnet wird wenn keine Einstellung gespeichert ist (leer)
Local preset Es i s t de r Name de r de r Nummer de r Loka l i s i e rung zugeordnet wird wenn eine Konfiguration gespeichert wird
ANMERKUNG = Man kann eine Einstellung mit dem gewuumlnschten Namen mit max 16 Buchstaben nur speichern wenn man die Schnittstelle uumlber den Computer benutzt
Bei der Wahl eines Programms erscheint folgendes Fenster
Anzeige des Namens der dem Programm zugeordnet istUm auf die Anwendung einzuwirken stehen 3 Auswahlmoumlglichkeiten zur Verfuumlgung
Das Programm wird im Speicher des AC 26N gespeichert
Das Programm wird geloumlscht
Das Programm wird geladen und ist bereit fuumlr die Benutzung
Save
Del
Load
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
37
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
38
BESCHREIBUNG DES MENUumlFENSTERS X-Over
Dieses Fenster erlaubt fuumlr jeden Ausgang einen Bassdurchgangsfilter einen Hochdurchgangsfilter oder mittels Kombination von beiden einen Banduumlbergangsfilter zu waumlhlenDer Filter ist ein Linkwitz-Riley wo man die Neigung von 12 dBoct 24dBoct oder 48 dBoct und die entsprechende Schnittfrequenz auswaumlhlen kann
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) AUSGANGSKANAumlLE
Die Steckverbinder am Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) FILTER CROSSOVERDen Filter nach Bedarf waumlhlen Man kann folgendes auswaumlhlen
Dis Kein Filter aktiviert
HP Hochdurchgangsfilter nur den Teil des Audiosignals durchlassen der uumlber der Schnittfrequenz liegt
LP Bassdurchgangsfilter nur den Teil des Audiosignals durchlassen der unter der Schnittfrequenz liegt
Filter-Konfiguration Tiefpass Hochpass
Nichts Dis Dis
Hochpass HP Dis
Tiefpass Dis LP
Bandpass HP LP
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
c) DAumlMPFUNGSNEIGUNGDie Daumlmpfungsneigung des Audiosignals auf der Basis der Verringerung auswaumlhlen die man erreichen moumlchte Je houmlher die Daumlmpfungsneigung bei gleicher Schnittfrequenz desto groumlszliger ist die Signalauswahl Man kann folgendes waumlhlen
12 entsprechend 12 dboct
24 entsprechend 24 dboct
48 entsprechend 48 dboct
d) SCHNITTFREQUENZErlaubt die Durchgangsfrequenz der niederen Frequenzen (Bassdurchgangsfilter) oder der hohen Frequenzen (Hochdruchgangsfilter) einzustellenDie Auswahl des Schnitts bezieht sich auf die Wiedergabe die man erreichen moumlchteDie benutzte Maszligeinheit ist Hz
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
BESCHREIBUNG DES MENUumlFENSTERS Matrix
Erlaubt fuumlr jeden Ausgang das Eingangssignal zu waumlhlen das als Quelle benutzt werden soll
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) AUSGANGSKANAumlLEIdentifizierung des einzustellenden Ausgangskanals
b) IDENTIFIZIERUNG DER EINGAumlNGEDen Signaltyp auswaumlhlen der nach eigener Anforderung jedem einzelnen Ausgang zugeordnet werden soll Man kann folgendes waumlhlen
In A Das Signal wird dem Eingang A zugeordnet
In B Das Signal wird dem Eingang B zugeordnet
In A+B Zuordnung der a lgebra ischen Summe der be iden Eingangssignale A und B
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
BESCHREIBUNG DES MENUumlFENSTERS Option
Erlaubt die Anzeige der Systemeinstellungen wie die Zuordnung der Ein- und Ausgaumlnge Daumlmpfung Displaykontrast und Firmware-Version
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B Src
Diese Option erlaubt die Einstellung des Audio-Signaltyps am Eingang
Analoge Audiosignale (Eingaumlnge A und B)
Digitale Audiosignale (Eingang AESEBU)
DigOut Src
An In =Audiosignale an den analogen Eingaumlngen
Dig In =Audiosignale am digitalen Eingang
OUT 1-2 =Audiosignale an den Ausgaumlngen 1 und 2
OUT 3-4 =Audiosignale an den Ausgaumlngen 3 und 4
OUT 5-6 =Audiosignale an den Ausgaumlngen 5 und 6
Input Mode
An In
Dig In
Indip =
Linked =
Diese Option erlaubt die Audioquelle zu waumlhlen die fuumlr den Steckverbinder AESEBU OUT (digitaler Ausgang) bestimmt ist
Erlaubt die Eingaumlnge zu konfigurieren
Sie sind unabhaumlngig und selbststaumlndig sie unterliegen keinen Verpflichtungen untereinander Sie sind verbunden und funktionieren im Stereo-Modus
Die Kompressoren Filter Verzoumlgerungen die Lautstaumlrke sind bei beiden Kanaumllen identisch
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
39
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
40
Atten PadZeigt an wie der Wahlschalter -6 dB auf der Ruumlckseite eingestellt ist [Ref 5] Dieser Wahlschalter muss aktiviert werden wenn das Level an den analogen Eingaumlngen zu hoch ist Der Wahlschalter wird uumlber die Taste aktiviert im Menuuml gibt es nur eine Anzeige
0dB = Wahlschalter nicht aktiviert
-6dB = Wahlschalter aktiviert
Contrast
10 heller 60 dunkler 100
Fw Vers
Die Eingangssignale sind dieselben wie die Eingangsquelle
Die Eingangssignale werden vom internen Prozessor um -6 dB gedaumlmpft
Erlaubt den Kontrast des LCD-Displays einzustellen um den Unterschied der Helligkeit auf den Installationsort auszurichten Ein deutlicheres Display erlaubt auf korrekte und schnelle Weise innerhalb der Menuumls zu surfenDie Hersteller-Einstellung am Ausgang liegt bei 60
Zeigt die Firmware-Version des Prozessors an
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
41
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
42
TECHNISCHE DATEN
Antwort in FrequenzDynamische GammaCMMRCrosstalkDistorsion
ProzessorFrequenz der DatenausarbeitungAnaloge Converter Verzoumlgerung der VerteilungSpeicherung der Konfigurationen
DisplayTastenBedienungen
Analoger Eingang ndeg2 x XLR (3-poliger Female Stecker)Impedanz des Eingangs gt10KOhmMaximales Level +21dBu ohne PAD
+27dBu bei PAD
Impedanz des Ausgangs 50OhmMaximales Level +21dBu Typ symmetrisch
Typ SPDIF-AESEBU (AES3)
Typ Entsprechend dem Standard des Eingang
Typ
Typ
NETZSPANNUNGABMESSUNGEN (BXHXT)GEWICHT
AUDIO-LEISTUNGEN+- 01dB (20 to 30kHz)116dB typgt 60dB (50 to 10kHz)lt -100dB0002 (1kHz +4dBu)
DIGITALE AUDIO-LEISTUNGEN DSP 2856-bit 48KHz24-bit BURR BROWN15ms32 preset
KONTROLLEN LCD GrafikESC - MENU - FUNCTIONS SELECTIONENTER
EIN-AUSGAumlNGE
Analoger Ausgang ndeg6 x XLR (3-poliger Male Stecker)
Digitaler Eingang ndeg1x XLR (3-poliger female Stecker)
Digitaler Ausgang ndeg1x XLR (3-poliger Male Stecker)
Ein-Ausgang Rdnet ndeg2 x XLR RJ45 (kabel CAT 5) USB Typ B
KONTROLLPARAMETER AUDIOStaumlrke -80dB a +20dB step 01dBVerzoumlgerung Eingang 0 a 729mS step 01 mS
Ausgang 0 a 340mS step 01mSPhasenrotation 0deg - 180deg
KOMPRESSIONSchwelle -80dB a +20dB step 01dBVerhaumlltnis 11 a Inf1 step 001Staumlrke am Ausgang 0dB a 40dB step 01dBAnschlusszeit 1mS a 1000mS step 01mSReleasezeit 1mS a 1000mS step 01mSBeibehaltungszeit 1mS a 1000mS step 01mS
EQUALIZER12 Equalizer fuumlr jeden Ein- und Ausgang
PEQ (parametrischer) Hi-shelf Lo-sheftFrequenz 20Hz a 20KHz step 1HzStaumlrke -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (lediglich PEQ)
FILTER CROSSOVERFilter Linkwitz Riley
HP HochdurchgangsfilterLP Bassdurchgangsfilter
Neigung 12dBoct - 24dBoct - 48dBoctSchnittfrequenz 5Hz a 20KHz step 1Hz
Full-range 100-240Vac 50-60Hz430482x43x130mm 19Kg
AnmerkungenSpezifikationen unterliegen Aumlnderungen ohne Vorankuumlndigung
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
INTRODUCTIONAC26N est un processeur audio numeacuterique pour la gestion de leacutequipement audio conccedilu pour des installations fixes et mobiles Il fonctionne selon une technologie de pointe avec des processeurs agrave 2856bits et des convertisseurs ADDA agrave 24-bits hautes performances Les fonctions du processeur sont les niveaux dentreacutee et de sortie le deacutelai (delay) la polariteacute 12 bandes deacutegalisation par canal dentreacutee et de sortie diffeacuterentes seacutelections de croisement (crossover) et un limiteur hautes performances Le controcircle des filtres a une reacutesolution de 1Hz Les entreacutees et les sorties peuvent ecirctre programmeacutees en plusieurs configurations pour satisfaire tous les besoins AC26N peut ecirctre controcircleacute en temps reacuteel et tous les paramegravetres peuvent ecirctre configureacutes depuis le pupitre frontale et par ordinateur avec interface graphique intuitive accessible via le logiciel laquoDVA Networkraquo et une connexion de reacuteseau deacutedieacutee RDnet ou USBLa mise agrave jour du logiciel pour lUniteacute centrale et DSP par ordinateur portable permet de maintenir le dispositif actualiseacute Il est possible denregistrer et de rappeler 32 configurations preacute-eacutequipeacutees de configuration
Contenu de lemballage - AC26N - Mode demploi- CD logiciel- Cacircble dalimentation
Caracteacuteristiques- 2 entreacutees et 6 sorties avec adressage flexible- Entreacutee et sortie steacutereacuteo AESEBU adressables - DSP 2856-bit- Convertisseurs AD BURR BWOWN 24-bit hautes performances- Freacutequence de reacutesolution des filtres 1 Hz - 12 eacutegaliseurs parameacutetriques pour chaque entreacutee et sortie- 2 filtres de croisement par sortie avec pente seacutelectionnable agrave 122448dBoct- DRC agrave configuration multiple hautes performances pour configuration limiteur
compression pour chaque entreacutee et sortie- Niveau reacuteglable en dB polariteacute et deacutelai pour chaque entreacutee et sortie- Mise agrave jour du micrologiciel par lordinateur- Affichage graphique agrave cristaux liquides- 32 preacutereacuteglages enregistrables par lutilisateur- Interface USB pour le controcircle et la configuration par ordinateur- Interface RDnet permettant de controcircler jusquagrave 256 dispositifs agrave distance
PC
PC
RDNETcontrol(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FONCTIONS DE LA FACE AVANT
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
COMMANDES ET FONCTIONS1) AFFICHAGE
Laffichage graphique agrave cristaux liquides permet de visualiser et deacutediter les informations de lAC26N sans utiliser lordinateur Le contraste peut ecirctre configureacute dans le menu principal
2) MANETTE Functions Selector et Push EnterCe controcircle permet de se deacuteplacer de seacutelectionner et de modifier les paramegravetres dans les menus affichables agrave leacutecranRotation de la manette (Functions Selectors)- permet de se deacuteplacer sur les diffeacuterentes pages du menu - permet de modifier les paramegravetres seacutelectionneacutesPression de la manette (Push Enter)- permet de seacutelectionnervalider les paramegravetres
3) Bouton ESC Ce controcircle permet de quitter les menus afficheacutes ou de revenir agrave la visualisation preacuteceacutedente
4) Bouton Menu Ce controcircle permet dacceacuteder directement au menu principal
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
Fra
nccedilais
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
43
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
Fra
nccedilais
44
DVA Network
AC26N est eacutequipeacute dune interface de reacuteseau proprieacutetaire deacutenommeacutee RDNET au moyen de laquelle il est possible de sinterfacer agrave lordinateur agrave travers un peacuteripheacuterique (RDNET control)
Pour cela un protocole de communication a eacuteteacute deacuteveloppeacute avec lequel il est possible de recevoir et denvoyer les donneacutees ce branchement permet de faire le monitorage en temps reacuteel des paramegravetres du diffuseur comme puissance de sortie tempeacuterature de lamplificateur eacutetat du limiteur etc Il est aussi possible de seacutelectionner diffeacuterentes eacutegalisations ou den creacuteer de nouvelles et de reacutegler les niveaux de volume souhaiteacutes au moyen dun plug-in approprieacute
On conseille de teacuteleacutecharger gratuitement le logiciel DVA Network directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
DVA USB Manager
On conseille de teacuteleacutecharger gratuitement le logiciel DVA USB Manager directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
Le micrologiciel du module amplificateur peut ecirctre remis agrave jour par le port USBPour rendre cette mise agrave jour possible et facile un programme speacutecifique a eacuteteacute deacuteveloppeacute
DOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
CONNEXIONS DU PANNEAU ARRIEgraveRE
1586 75 141210 11 13 169 17
14) Connecteur ldquo USBrdquoCe connecteur USB (type B) permet de connecter le processeur agrave un ordinateur pour le controcircle et la mise agrave jour du micrologiciel via un programme deacutedieacute (DVA Network)
15) PRISE DALIMENTATION MAINSPermet la connexion du cacircble dalimentation fourni de seacuterie
16) PORTE-FUSIBLE FUSELogement pour fusible de ligne
17) INTERRUPTEUR GENERAL POWERLinterrupteur permet de mettre en marche ou deacuteteindre le controcircleur audio
COMMANDES ET FONCTIONS
5) SELECTEUR ldquo-6dBrdquoLe seacutelecteur permet de reacuteduire de 6dB les niveaux dentreacutee analogiques XLR [6] tout en compensant les niveaux eacuteleveacutes de sortie des meacutelangeurs ou dautres dispositifs audio Quand la barre du niveau de signal des entreacutees sur laffichage [1] reste au maximum cela indique que le niveau du signal entrant est eacuteleveacute Il est alors conseilleacute dutiliser latteacutenuation -6dBIl est possible de veacuterifier quand le seacutelecteur est activeacute par le menu Option
6) CONNECTEURS DENTREE ldquoArdquo ET ldquoBrdquoEntreacutees eacutequilibreacutees au niveau de la ligneIls sont en mesure daccepter des connecteurs XLR macircles
7) CONNECTEURS DE SORTIE ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo ET ldquo6rdquoSorties eacutequilibreacutees au niveau de la ligne Ils sont en mesure daccepter des connecteurs XLR femelles
Prendre garde agrave brancher convenablement les sorties sur les diffuseurs ou les amplificateurs en fonction des configurations de chaque canal pour eacuteviter des deacutegacircts et des problegravemes de fonctionnement
Section ldquoAESEBUrdquo
8) CONNECTEUR DENTREE INOutre les entreacutees audio analogiques une entreacutee audio numeacuterique SPDIF-AESEBU (AES3) a eacuteteacute preacutevue et peut ecirctre seacutelectionneacutee par le menu de setupLentreacutee requiert une connexion eacutequilibreacutee en utilisant un connecteur XLR avec un cacircble agrave 3 conducteurs de 110ohm torsadeacute
9) CONNECTEUR DE SORTIE OUTCe connecteur permet de relancer le signal audio dans les entreacutees analogiques ou numeacuteriques ou sur les sorties La source doit ecirctre reacutegleacutee par le menu OptionLa connexion sera conforme agrave la mecircme norme que lentreacutee [reacutef8]
Section ldquoRDNETrdquo
10) CONNECTEUR DENTREE DATA INPUTConnecteur RJ45 entreacutee de donneacutees
11) CONNECTEUR DE SORTIE DATA LINKConnecteur RJ45 sortie de donneacutees pour la connexion de seacuterie en cascade
12) VOYANT LUMINEUX ONCe voyant de couleur verte sallume uniquement quand lAC26N a reconnu et est connecteacute agrave luniteacute principale RDNET par lordinateur
13) VOYANT LUMINEUX ACTIVECe voyant de couleur jaune clignote quand une transmission des donneacutees est active entre RDNET et le dispositif
PUSH
P SHU
SHPU
P SHU
PUSH
CONNEXIONS
Audio analogiquesLes connexions eacutequilibreacutees permettent de reacuteduire au minimum le bruit provoqueacute par les cacircbles et dutiliser de longs cacircblesCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLe connecteur XLR doit ecirctre brancheacute avec la broche 1 agrave la masse la broche 2 au chaud (+) et la broche 3 au froid (-) En cas de cacircble blindeacute brancher le blindage agrave la broche 1Les cacircbles de connexion XLR-XLR et XLR-Jack14(63mm) peuvent semployer pour la connexion agrave lAC26N
12
3
Entreacutee
Entreacutee
XLR - femme
XLR - femme
1 2
3
Sortie
Sortie
XLR - Macircle
XLR - Macircle
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2 = Point chaudPhase +VE
Broche 3 =Point froidPhase -VE
Broche 3 =Point froidPhase -VE
Anneau
Manchon
Pointe Point chaudPhase +VE
Anneau = Point froidPhase -VE
ManchonB Masselindeacute
Pointe
Les connexions deacuteseacutequilibreacutees peuvent semployer mecircme si le bruit provoqueacute par les cacircbles augmente Les cacircbles ne peuvent deacutepasser 5m de longCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLes connexions deacuteseacutequilibreacutees peuvent abaisser le niveau du signal entrant de 6dB Pour remeacutedier agrave cet inconveacutenient il faut brancher la broche 3 agrave la masse mecircme si cela augmente le bruit
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
45
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
46
12
3
1 2
3
Pointe Manchon
Pointe = Signal
Broche 3 = Link to Pin 1
Broche 3 = Link to Pin 1
ManchonB Masselindeacute
Audio numeacuteriques (AESEBU)
AESEBU (protocole AES3) est une entreacutee eacutequilibreacutee isoleacutee eacutelectriquement agrave laide dun transformateur Elle permet demployer deux canaux audio dans un seul cacircble bipolaire blindeacute Les caracteacuteristiques du cacircble doivent ecirctre de 3 pocircles impeacutedance 100ohm torsadeacute et blindeacute avec connecteur XLR (AES3 standard)
RJ 45
|1|2|3|4|5|6|7|8|
RDnet
Chaque port RDNet des Control 2 et Control 8 peut ecirctre brancheacute agrave un maximum de 32 dispositifs compatibles placeacutes en cascade Dans lexemple suivant le port de luniteacute de controcircle RDNET CONTROL 2 est relieacute agrave lentreacutee DATA INPUT dun AC26N dont la sortie parallegravele DATA LINK est envoyeacutee agrave lentreacutee de lAC26N successif Dans lexemple [n] est un nombre compris entre 3 et 32 (limite maximale des dispositifs que lon peut relier agrave un sous-reacuteseau)
La longueur totale du cacircble CAT5 dun sous-reacuteseau NE peut PAS deacutepasser 900 megravetres
Le connecteur doit ecirctre relieacute comme 1 ndash disponible pour dautres fonctions (par exemple audio +) 2 ndash disponible pour dautres fonctions (par exemple audio )3 ndash disponible pour dautres fonctions (par exemple masse analogique)4 ndash masse numeacuterique5 ndash masse numeacuterique6 ndash disponible pour dautres fonctions (par exemple alimentation)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
MISE EN MARCHE
Lors de la mise en marche du dispositif linitialisation deacutebute et dure quelques secondes Leacutecran affiche le modegravele le logo et la barre de progression du chargement du programme
En fin de processus dinstallation leacutecran affiche la fenecirctre du menu Meters Pour connaicirctre les indications en deacutetail consulter le paragraphe DESCRIPTION FENETRE MENU Meters
LAC26N est precirct agrave lemploi
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION ET VISUALISATION
Pour entrer dans la fenecirctre du menu principal il faut pousser sur la touche MENU ( ) agrave lavant du dispositifDune page quelconque du menu en poussant sur la touche ESCrdquo ( ) on revient automatiquement sur la page-eacutecran preacuteceacutedente
MENU PRINCIPAL
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Le processeur contient six menus Ils montrent etou configurent les paramegravetres du systegravemeLes menus principaux sont
Meters Visualisation des niveaux des entreacutees et des sorties visualisation du programme utiliseacute et eacutetat mute rapide
Preset Meacutemoriser enregistrer et eacuteliminer les configurations du systegraveme
Matrix seacutelectionner les sorties en fonction du signal entrant
Ch Job configuration de chaque signal
X-Over configurer les freacutequences de coupure et les types de filtres pour chaque sortie
Option attribution des entreacutees et des sorties contraste daffichage la version du micrologiciel les entreacutees et dautres options
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
47
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
48
DESCRIPTION DE LA FENETRE MENU Metersrdquo
Cette fenecirctre permet de visualiser les configurations et leacutetat geacuteneacuteral des entreacutees et des sorties la version du programme utiliseacute son eacutetat et le mode de pilotage du systegraveme
Les menus et les options afficheacutees peuvent se seacutelectionner en tournant la manette ldquoFUNCTIONS SETECTORrdquo ( ) Pour avoir accegraves agrave linteacuterieur de la seacutelection il faut mettre le paramegravetre souhaiteacute en eacutevidence et pousser sur la manette ldquoPush Enterrdquo ( | ) Il faut en faire de mecircme pour seacutelectionner etou modifier les options dans les commandes du menu
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositifAvec des signaux dentreacutee numeacuteriques les indications ldquoArdquo et ldquoBrdquo correspondent agrave lentreacuteeEn tournant la manette ldquoFUNCTIONS SELECTORrdquo [2] on fait deacutefiler en mode cyclique les canaux dentreacutee de sortie et lindication de mute geacuteneacuteral (d) le canal seacutelectionneacute est mis en eacutevidence
b) BARRE DE NIVEAU DE COMPRESSIONMUTE CANAL
COMPRESSION DE SIGNALLa compression du signal est visualiseacutee par le deacutefilement de la barre de droite de haut en bas
MUTE Chaque canal peut ecirctre placeacute en mute Seacutelectionner le canal et pousser sur la manette ldquoPush Enterrdquo [2] pour valider le changement deacutetat Lindication du canal sera remplaceacutee par la lettre M et la barre sera totalement mise en eacutevidencePour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterations
c) BARRE DE NIVEAU DE SIGNALLindication du niveau de chaque canal est signaleacutee par le deacutefilement de la barre de gauche
d) MUTE GENERALIl est possible de mettre simultaneacutement toutes les entreacutees et les sorties en mute Tourner la manette ldquoFUNCTIONS SELECTORrdquo seacutelectionner la lettre M et pousser sur la manette Push EnterPour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterationsLe mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) MODES DE COMMANDEIl affiche le mode dutilisation etou les dispositifs qui sont relieacutes agrave lAC26N
Local = utilisation autonome Aucune connexion agrave un dispositif exteacuterieur
NET = relieacute directement au reacuteseau deacutedieacute RDNet et agrave lordinateur
USB = relieacute directement agrave un ordinateur par cacircble USB
f) INDICATION DETAT DE PARAMETRAGECette indication permet de constater si un ou plusieurs paramegravetre(s) du programme chargeacute aont eacuteteacute modifieacute(s) par rapport au dernier sauvetage
= programme dorigine
= programme avec des paramegravetres modifieacutes
g) PROGRAMME CONFIGURELe chiffre indique le programme chargeacute et utiliseacute par le systegraveme agrave lemplacement de sauvetage Consulter le menu de Preset pour de plus amples deacutetails
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
DESCRIPTION DE LA FENETRE MENU Ch Job
Cette fenecirctre permet dafficher la configuration de chaque canal
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) NIVEAU DU SIGNALIndique le gain du signal Laugmentation de lintensiteacute dun signal est libelleacutee en deacutecibel (dB) Le paramegravetre peut ecirctre seacutelectionneacute de -8000dB agrave +2000dB avec des pas de 001dB Une augmentation de 6dB est eacutegale approximativement au redoublement agrave leacutechelle lineacuteaire du niveau du signal sous tensionAvec un gain supeacuterieur agrave 0dB le signal est amplifieacute tandis quavec un gain infeacuterieur agrave 0dB le signal est atteacutenueacute
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
49
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
50
c) DELAI DU SIGNAL (DELAY)Le signal audio reproduit peut ecirctre retardeacute pour permettre lalignement acoustique Cela compense les diffeacuterentes positions des diffuseurs pendant linstallation et la reproduction sonore Il se libelle en mS Le paramegravetre peut ecirctre seacutelectionneacute de 00mS agrave 729mS avec un pas de 01mSPour aligner un signal audio il est possible dutiliser la formule suivante
Deacutelai = (GAPx1000)344
Deacutelai = ms (en millisecondes)GAP = distance du diffuseur du point de reacutefeacuterence (en megravetres)Vitesse du son = 344ms
d) MUTEChaque canal peut ecirctre placeacute en mute La mecircme commande peut ecirctre activeacutee dans la fenecirctre du menu meters NB Le mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) PhasePermet la rotation de phase de 180deg par rapport au signal entrantCette rotation permet loptimisation surtout des basses freacutequences dans les installations complexes
f) EGALISATIONCette commande ouvre la fenecirctre du menu deacutegalisation de chaque canal Elle sert surtout pour corriger une ou plusieurs freacutequences qui doivent ecirctre atteacutenueacutees ou augmenteacutees
M M
LAC26N gegravere 12 filtres par canal dentreacutee et sortie avec trois types de configurations diffeacuterentes - Leacutegaliseur PEQ (peaking equalizer) est ideacuteal pour identifier isoler et
corriger une seule plage de freacutequences bien deacutetermineacutee Toutes les freacutequences passent mais il augmente ou diminue uniquement celles autour de la freacutequence centrale pour une bande preacutecise et un gain deacutefini
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessus de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessous de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
f Numeacuterotation des 12 filtres disponibles pour cette entreacutee ou cette sortie1
f Le type de filtre est afficheacute 2
Dis Deacutesactiveacute (absent)
PEQ Peaking equlizer
Sh H Filtre high-shelf
Sh L Filtre high-shelf
Exemples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
REMARQUELe paramegravetre Bw deacutetermine le champ de freacutequences adjacent agrave la freacutequence configureacutee ougrave est activeacute le filtre Plus la valeur Bw est eacuteleveacutee plus vaste est le champ de freacutequences (1Bw=1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONCette commande ouvre la fenecirctre du menu de compression de chaque canal
g1) TresholdIdentifie le seuil ougrave commence le rapport de compression La valeur de base 11
g2) RatioIndique le rapport de conversion entre le signal entrant et le signal sortant
g3) Post Gain Attach Release HoldCes donneacutees deacutependent du rapport de conversion que lon veut obtenir - Post Gain est le gain de sortie- Attack est le temps dattaque - Release est le temps de relacircchement- Hold est le temps de maintien
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
52
DESCRIPTION DE LA FENETRE MENU Preset
Cette fenecirctre permet de meacutemoriser jusquagrave 32 configurations dans lAC26NLe fabricant fournit le systegraveme avec un programme configureacute et enregistreacute en position 0 et non susceptible deacutecrasement
032 Elle indique lemplacement de sauvetage de la configurationCe numeacutero apparaicirct dans la fenecirctre Meters en position (g) A tout moment le programme utiliseacute peut ecirctre afficheacute par lutilisateur
Empty Preset Cest le nom qui est associeacute au numeacutero de lemplacement quand aucune configuration (vide) nest enregistreacutee
Local preset Local preset est le nom qui est associeacute au numeacutero de lemplacement quand on enregistre une configuration NB = Il est possible denregistrer une configuration avec lenom souhaiteacute de 16 lettres tout au plus agrave condition que lonutilise linterface via lordinateur
Le nom du programme assigneacute est indiqueacutePour toucher agrave lapplication 3 choix soffrent agrave vous
Save Le programme est enregistreacute en meacutemoire de lAC26N
Del Le programme est effaceacute
Load Le programme est chargeacute et precirct agrave lemploi
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
51
DESCRIPTION DE LA FENETRE MENU X-Over
Cette fenecirctre permet de seacutelectionner un filtre passe bas un filtre passe haut ou par la combinaison des deux de creacuteer un filtre passe bande pour chaque sortieLe filtre actif est un Linkwitz-Riley qui permet de seacutelectionner la pente de 12dBoct 24dBoct ou 48dBoct et sa freacutequence de coupure
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) CANAUX DE SORTIE
Les connecteurs de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) FILTRE CROSSOVERSeacutelectionner le filtre selon les besoins Il est possible de seacutelectionner
Dis Aucun filtre activeacute
HP Filtre passe-haut laisse passer uniquement la partie de signal audio supeacuterieure agrave la freacutequence de coupure
LP Filtre passe-bas laisse passer uniquement la partie de signal audio infeacuterieure agrave la freacutequence de coupure
Configuration du filtre Passe-haut Passe-bas
Rien Dis Dis
Passe-haut HP Dis
Passe-bas Dis LP
Passe-bande HP LP
12dBoct
24dBoct
Hz
dB
Ga
in 48dBoct
12dBoct
24dBoct
Hz
dB
Ga
in
48dBoct
c) PENTE DATTENUATIONSeacutelectionner la pente datteacutenuation du signal audio en fonction de la diminution que lon veut obtenir Plus la pente datteacutenuation est eacuteleveacutee agrave eacutegaliteacute de freacutequence de coupure plus eacuteleveacutee sera la seacutelection du signal Il est possible de seacutelectionner
12 correspond agrave 12dboct
24 correspond agrave 24dboct
48 correspond agrave 48dboct
d) FREQUENCE DE COUPUREElle permet de reacutegler la freacutequence de passage des freacutequences infeacuterieures (filtre passe-bas) ou des freacutequences supeacuterieures (filtre passe-haut) uniquementLe choix de la coupure deacutepend de la reproduction que lon veut obtenirLuniteacute de mesure utiliseacutee est lHz
Hz
Hz
dB
dB
Ga
in
f0
f0
0dB0dB
0dB
-6dB
freacutequence
freacutequence
freacutequence
freacutequence
Ga
in
f0
0dB
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
53
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
54
DESCRIPTION DE LA FENETRE MENU Matrix
Elle permet de seacutelectionner le signal entrant agrave utiliser comme source pour chaque sortie
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) CANAUX DE SORTIEIdentification du canal sortant agrave reacutegler
b) IDENTIFICATIONS DES ENTREESSeacutelectionner le type de signal agrave associer agrave chaque sortie en fonction des besoins Il est possible de seacutelectionner
In A Le signal entrant A est associeacute
In B Le signal entrant B est associeacute
In A+B La somme algeacutebrique des deux signaux entrants A et B est associeacutee
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
DESCRIPTION DE LA FENETRE MENU Option
Permet dafficher les reacuteglages du systegraveme comme lassignation des entreacutees et des sorties latteacutenuation le contraste de laffichage et la version du logiciel
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcCette option permet de reacutegler le type de signal audio entrant
An In =signaux audio analogiques (entreacutees ldquoArdquo et ldquoBrdquo)
Dig In =signaux audio numeacuteriques (entreacutee AESEBU)
DigOut SrcCette option permet de seacutelectionner la source audio qui sera adresseacutee sur le connecteur AESEBU OUT (sortie numeacuterique)
An In = signaux audio des entreacutees analogiques
Dig In =signaux audio sur lentreacutee numeacuterique
OUT 1-2 = signaux audio sur les sorties 1 et 2
OUT 3-4 = signaux audio sur les sorties 3 et 4
OUT 5-6 = signaux audio sur les sorties 5 et 6
Input ModePermet de configurer les entreacutees
Indip = sont indeacutependantes et autonomes Ne sont soumises agrave aucun type de lien
Linked = sont unies et fonctionnent en mode steacutereacuteo Les compresseurs les filtres les deacutelais le volume sont identiques pour les deux canaux
Atten PadIndique le mode de reacuteglage du seacutelecteur ldquo-6dBrdquo placeacute agrave larriegravere [reacutef 5] Il faut activer ce seacutelecteur quand les niveaux dentreacutee analogiques sont trop eacuteleveacutes Le seacutelecteur sactive uniquement par le bouton Dans le menu il sagit dune simple visualisation
0dB = seacutelecteur non activeacute Les signaux dentreacutee sont identiques agrave la source entrante
-6dB = seacutelecteur activeacute Les signaux entrants sont atteacutenueacutes de -6dB par le processeur interne
ContrastIl permet de reacutegler le contraste de laffichage agrave cristaux liquides pour compenser la diffeacuterence de luminositeacute avec le lieu dinstallation Une plus grande clarteacute de laffichage permet de naviguer convenablement et rapidement dans les menusLe reacuteglage agrave la sortie de lusine du fabricant est de 60
10 plus clair 60 plus fonceacute 100
Fw VersIndique la version du logiciel du processeur
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
55
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
56
DONNES TECHINIQUES
PERFORMANCES AUDIOReacuteponse en freacutequence +- 01dB (20 to 30kHz)Plage dynamique 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsion 0002 (1kHz +4dBu)
PERFORMANCES AUDIO NUMERIQUES Processeur DSP 2856-bit Freacutequence de traitement des donneacutees 48KHzConvertisseurs analogiques 24-bit BURR BROWNDeacutelai de propagation 15msMeacutemorisations des configurations 32 preset
CONTROLES Affichage LCD graficoBoutonsCommandes ESC - MENU - FUNCTIONS SELECTION
ENTERENTREESSORTIESEntreacutee analogique ndeg2 x XLR (3 broches femelle)
Impeacutedance dentreacutee gt10KOhmNiveau maximum +21dBu senza PAD
+27dBu con PADSortie analogique ndeg6 x XLR (3 broches macircle )
Impeacutedance de sortie 50OhmNiveau maximum +21dBuType Balanceacute
Entreacutee numeacuterique ndeg1x XLR (3 broches femelle)Type SPDIF-AESEBU (AES3)
Sortie numeacuterique ndeg1x XLR (3 broches macircle )Type conforme agrave la norme de lentreacutee
EntreacuteesSortie Rdnet ndeg2 x XLR RJ45 (cacircble CAT 5)USB Type B
PARAMETRES DE CONTROLE DU SONGain -80dB a +20dB eacutetape 01dBDeacutelai Entreacutee 0 a 729mS eacutetape 01 mS
Sortie 0 a 340mS eacutetape 01mSRotation de phase 0deg - 180deg
COMPRESSIONSeuil -80dB a +20dB eacutetape 01dBRapport 11 a Inf1 eacutetape 001Gain agrave la sortie 0dB a 40dB eacutetape 01dBTemps dattaque 1mS a 1000mS eacutetape 01mSTemps de relacircchement 1mS a 1000mS eacutetape 01mSTemps de maintien 1mS a 1000mS eacutetape 01mS
EGALISEURS12 eacutegaliseurs pour chaque entreacutee et sortieType PEQ (parameacutetrique) Hi-shelf Lo-sheft
Freacutequence 20Hz a 20KHz eacutetape 1HzGain -30dB a +15dB eacutetape 001dBBande 005dB a 2dB eacutetape 001dB (uniquement pour PEQ)
FILTRES CROSSOVERFiltre Linkwitz Riley
Type HF high-shelfLF low-shelf
Pente 12dBoct - 24dBoct - 48dBoctFreacutequence de coupure 5Hz a 20KHz eacutetape 1Hz
ALIMENTATION Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)POIDS 19Kg
Remarques Speacutecifications sujettes agrave modifications sans preacuteavis
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
2 VIE ATTIVO2 WAY ACTIVE
3 VIE PASSIVO3 WAY PASSIVE
L
L
A
A
HIGH L
MID L
LOW HIGHMID RHIGHMID L
LOW L
HIGH R
MID R
LOW R
R
R
B
B
1
1
2
2
3
3
456
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
Menu Matrix configurationMatrix
57 58
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
EROUIG ATRIX TNM
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
OU
TP
UT
1
OU
TP
UT
2
OU
TP
UT
3
OU
TP
UT
4
OU
TP
UT
5
OU
TP
UT
6
AE
S-E
BU
OU
TP
UT
INP
UT
A
AE
S-E
BU
INP
UT
INP
UT
B
D D D D D D
D D
A A A A A A
A SA
MP
LE
RA
TE
CO
NV
A
LIN
KA
BL
E
SC
HE
MA
A B
LO
CC
HI -
BL
OC
K D
IAG
RA
MB
LO
CK
SC
HA
LT
BIL
D -
SC
HE
MA
S F
ON
CT
ION
NE
LS
LINE ARRAY SUB MONO ATTIVO
LINE ARRAY SUB MONO ACTIVEINGRESSI - INPUT
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
L
L
L
A
A
A
AESEBU IN
AESEBU IN
AESEBU IN
AESEBU OUT
AESEBU IN
AESEBU IN
AESEBU OUT
R
R
R
LR
B
B
B
123456
HIGHMID L
HIGHMID L HIGHMID R
HIGHMID R
LOW L LOW R
LAYER
DISPLAY MEMORY
FADER MODE
LAYER
DISPLAY MEMORY
FADER MODE
Ingresso ANALOGICO
ANALOG Input
Collegamento in cascata
Link connections
Ingresso DIGITALE
DIGITAL inputA B
BALANCED AUDIO INPUTS
-6dB
PUSH PUSH
IN OUT
AES EBUPUSH
Oppure
or
Oppure
or
Menu Option configurationOption
Menu Option configurationOption Menu Option configurationOption
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type Analog
AES out An In
Input type Analog
AES out An In
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
59 60
InA-B Src Dig InInA-B Src Dig InInA-B Src An InInA-B Src An In
frequenzaHz
dB
Gu
ad
ag
no
60 200 2800
0dB0dB
-6dB
Esempio di un sistema a 3-vie
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
Out 1 Out 2 Out 3
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Esempio di un sistema a 3-vie
61 62
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
26NAC 26NAC
R TE
DO
R
MO LEU O R CE S
E O TR L A
S O
O C ND I P
P hsuernE t
o su cti nF nel rS e tc o
E CSME UN
IGCHTE OL SN EOBd
ocaL l
M
0
484
467
430
44
31
75
12
7
DIMENSIONI DIMENSIONSABMESSUNGEN DIMENSIONS
Digitales Audio (AESEBU)AESEBU (Protokoll AES3) ist ein ausgeglichener und uumlber einen Transformator elektrisch isolierter Eingang Er erlaubt die Benutzung von zwei Kanaumllen an einem einzigen abgeschirmten bipolaren Kabel Das gedrillte Kabel muss 3-polig sein eine Impedanz von 100 Ohm haben und mit einem XLR-Steckverbinder (AES3 Standard) abgeschirmt sein
RdnetJeder Port RDNet an Control 2 und Control 8 kann an max 32 kompatiblen Vorrichtungen die in Kaskade geschaltet sind angeschlossen werden Im nachstehenden Beispiel ist der Port der Kontrolleinheit RDNET CONTROL 2 am Eingang DATA INPUT eines AC 26N angeschlossen dessen paralleler Ausgang DATA LINK zum Eingang des naumlchsten AC26N geht Im Beispiel ist [n] eine Nummer zwischen 3 und 32 (maximale Anzahl der anschlieszligbaren Vorrichtungen an nur einem Netz)
RJ 45
|1|2|3|4|5|6|7|8|
Die Gesamtlaumlnge des Kabels CAT5 eines Unternetzes kann NICHT laumlnger als 900 Meter sein
Der Steckverbinder muss wie folgt angeschlossen sein1 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio +) 2 ndash Verfuumlgbar fuumlr andere Funktionen (zB Audio -)3 ndash Verfuumlgbar fuumlr andere Funktionen (zB analoge Masse)4 ndash digitale Masse5 ndash digitale Masse6 ndash Verfuumlgbar fuumlr andere Funktionen (zB Versorgung)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
EINSCHALTEN
Beim Einschalten der Vorrichtung startet die Initialisierung die einige Sekunden lang dauert Auf dem Display wird das Modell das Logo und der Fortschrittsbalken der Ladung des Programms angezeigt
Nach der Initialisierung erscheint auf dem Display das Menuumlfenster Meters Um die Angaben im Detail zu erfahren beziehen Sie sich bitte auf das Kapitel BESCHREIBUNG DES MENUumlFENSTERS Meters
AC26N kann jetzt benutzt werden
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
MENUrsquo PRINCIPALE
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Die sechs Menuumls im Prozessor zeigen undoder konfigurieren die Systemparameter
Anzeige der Levels der Ein- und Ausgaumlnge Anzeige des benutzten Programms und dessen Status Mute schnell
Speicherung Speicherung und Eliminierung der Systemkonfigurationen
Auswahl der Ausgaumlnge je nach Eingangssignal
Konfiguration jedes einzelnen Kanals
Konfiguration der Schnittfrequenzen und der Filtertypen fuumlr jeden einzelnen Ausgang
Zuordnung der Ein- und Ausgaumlnge Kontrast des Displays Firmware-Version Eingaumlnge und andere Optionen
Das Menuuml und die einzelnen Optionen der Anzeige koumlnnen durch Drehen des Drehgriffes FUNKTIONS SELECTOR ( ) ausgewaumlhlt werden
Die Hauptmenuumls sind
Meters
Preset
Matrix
Ch Job
X-Over
Option
Um die Auswahl zu treffen muss der gewuumlnschte Parameter auswaumlhlt und der Drehgriff Push Enter( | ) gedruumlckt werdenDas selbe Verfahren muss fuumlr die Auswahl undoder die Aumlnderung der Optionen innerhalb der Menuumlpunkte angewendet werden
BESCHREIBUNG DES MENUumlFENSTERS Meters
Diese Seite erlaubt die Konfigurationen und den allgemeinen Status der Ein- und Ausgaumlnge der benutzten Programmversion dessen Status und die Steuerung des Systems anzuzeigen
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
KONFIGURATION UND ANZEIGE
Um in das Fenster des Hauptmenuumls zu gelangen muss die Taste Menuuml ( ) auf der Frontseite der Vorrichtung gedruumlckt werdenMit der Taste ESC ( ) kehrt man von jeder Seite des Menuumls auf die vorherige Seite zuruumlck
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
33
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
34
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziertBei den digitalen Eingangssignalen entspricht die Angabe A und B dem EingangDreht man den Drehgriff FUNCTIONS SELECTOR [2] durchlaumluft man zyklisch die Ein- und Ausgangskanaumlle und die Angabe Mute allgemein (d) der ausgewaumlhlte Kanal wird hervorgehoben
b) BALKEN FUumlR DAS KOMPRESIONSLEVELMUTE KANAL
SIGNALKOMPRESSIONDie Signalkompression wird durch das Gleiten des rechten Balkens von oben nach unten angezeigt
MUTE Jeder einzelne Kanal kann auf Mute gestellt werden Den Kanal auswaumlhlen und den Drehgriff Push Enter [2] druumlcken um die Aumlnderung des Status zu bestaumltigen Die Angabe des Kanals wird durch den Buchstaben M ersetzt und der Balken wird komplett hervorgehobenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werden
c) BALKEN DES SIGNALLEVELSDie Anzeige des Levels jedes einzelnen Kanals wird durch das Gleiten des linken Balkens angezeigt
d) MUTE ALLGEMEINEs ist moumlglich alle Ein- und Ausgaumlnge gleichzeitig auf Mute zu schalten Den Drehgriff FUNCTIONS SELECTOR drehen den Buchstaben M waumlhlen und dann den Drehgriff Push Enter druumlckenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werdenDie allgemeine Stummschaltung hat eine houmlhere Prioritaumlt als die Stummschaltung der einzelnen Kanaumlle
e) ANSTEUERUNGSARTENEs wird angezeigt wie AC26N benutzt wird undoder an welchen Vorrichtungen es angeschlossen ist
= Benutzung stand-alone Kein Anschluss an einer externen Vorrichtung
= Direkt am Netz RDnet und am Computer angeschlossen
= Uumlber USB-Kabel direkt am Computer angeschlossen
f) ANZEIGE DES STATUS DER EINSTELLUNGENHier wird angezeigt ob einer oder mehrere Parameter des geladenen Programms im Vergleich zur letzten Speicherung veraumlndert wurden
Original-Programm
Programm mit veraumlnderten Parametern
g) EINGESTELLTES PROGRAMMDie Nummer zeigt das vom System geladene und benutzte Programm in Bezug auf die Lokalisierung der Speicherung an Fuumlr weitere Details beziehen Sie sich bitte auf das Menuuml Preset
Local
NET
USB
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
BESCHREIBUNG DES MENUumlFENSTERS Ch Job
Dieses Fenster erlaubt die Anzeige der Konfiguration jedes einzelnen Kanals
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) SIGNALLEVELZeigt die Signalstaumlrke an Das Ansteigen der Signalintensitaumlt wird in Dezibel (dB) ausgedruumlckt Der Parameter kann zwischen -8000 dB und +2000 dB in Schritten von 001 dB ausgewaumlhlt werden Ein Anstieg von 6 dB ist fast gleich eine Verdoppelung in linearer Skala des Spannungswertes des SignalsBei einer Staumlrke von 0 dB wird das Signal verstaumlrkt waumlhrend es ein einer Staumlrke von weniger als 0 dB abgeschwaumlcht wird
c) VERZOumlGERUNG DES SIGNALS (DELAY)Das wiedergegebene Audio-Signal kann verzoumlgert werden um die akustische Ausrichtung zu erlauben Dies gleicht die verschiedenen Positionen der Lautsprecher bei der Installation und Klangwiedergabe aus und wird in mS ausgedruumlckt Der Parameter kann zwischen 00 mS und 729 mS in Schritten von 01mS ausgewaumlhlt werden
Um ein Audiosignal auszurichten kann folgende Formel benutzt werden
Verzoumlgerung = GAPx1000)344
Verzoumlgerung = mS (in Millisekunden ausgedruumlckt)GAP = Abstand des Lautsprechers vom Referenzpunkt (in Metern ausgedruumlckt)Klanggeschwindigkeit = 344 ms
d) MUTEJeder einzelne Kanal kann auf Mute gestellt werden Derselbe Befehl kann im Fenster des Menuumls Meters aktiviert werden PS Die al lgemeine Stummschaltung hat eine houmlhere Priori taumlt als die Stummschaltung der einzelnen Kanaumlle
e) PHASEErlaubt die Phasenrotation um 180deg zum EingangssignalDiese Rotation erlaubt vor Allem die Optimierung der niederen Frequenzen bei komplexen Installationen
f) ENTZERRUNGENDieser Befehl oumlffnet das Menuumlfenster fuumlr die Entzerrung des einzelnen Kanals Er wird vor Allem benutzt um eine oder mehrere Frequenzen zu korrigieren die gedaumlmpft oder verstaumlrkt werden muumlssen
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
35
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
36
AC26N verwaltet 12 Filter fuumlr jeden einzelnen Ein- und Ausgangskanal mit drei verschiedenen Konfigurationen- Equalizer PEQ (peaking equalizer) ist ideal um nur ein bestimmtes Frequenzband
zu identifizieren zu isolieren und zu korrigieren Es gehen alle Frequenzen durch aber nur die um die mittlere Frequenz steigt und sinkt um eine bestimmte Bandbreite und eine bestimmte Staumlrke
- Equalizer High-Shelf geht alle Frequenzen durch aber die Frequenzen uumlber der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
- Equalizer Low-Shelf geht alle Frequenzen durch aber die Frequenzen unter der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
f Nummerierung der 12 verfuumlgbaren Filter fuumlr diesen Ein- oder Ausgang1
f2 Es wird der Filtertyp angezeigt
Dis Ausgeschaltet (nicht vorhanden)
PEQ Peaking equalizer
Sh H Filter High-Shelf
Sh L Filter Low-shelf
Beispiele PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
ANMERKUNGDer Parameter Bw legt das Frequenzfeld neben der eingestellten Frequenz fest wo der Filter aktiviert wird je houmlher der Bw-Wert desto houmlher das Frequenzfeld (1Bw=1 Oktave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filter High-Shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filter Low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) KOMPRESSIONDieser Befehl oumlffnet das Menuumlfenster fuumlr die Kompression des einzelnen Kanals
g1) TresholdIdentifiziert die Schwelle an der das Kompressionsverhaumlltnis beginnt Der Basiswert 11
g2) RatioIdentifiziert das Kompressionsverhaumlltnis zwischen dem Ein- und Ausgangssignal
g3) Post Gain Attach Release HoldDiese Daten entsprechen dem Kompressionsverhaumlltnis das man erreichen moumlchte
Post Gain ist der Gewinn am AusgangAttack ist die Anschlusszeit Release ist die ReleasezeitHold ist die Beibehaltungszeit
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
BESCHREIBUNG DES MENUumlFENSTERS Preset
Dieses Fenster erlaubt bis zu 32 Konfigurationen im AC26N zu speichernDer Hersteller liefert das System mit einem voreingestellten Programm das auf Position 0 gespeichert ist und nicht uumlberschrieben werden kann
032 Es zeigt die Lokalisierung der Speicherung der KonfigurationDiese Nummer erscheint auch im Fenster Meters auf der Position (g) Das benutzte Programm kann jederzeit vom Benutzer angezeigt werden
Empty Preset Es ist der Name der der Nummer der Lokalisierung zugeordnet wird wenn keine Einstellung gespeichert ist (leer)
Local preset Es i s t de r Name de r de r Nummer de r Loka l i s i e rung zugeordnet wird wenn eine Konfiguration gespeichert wird
ANMERKUNG = Man kann eine Einstellung mit dem gewuumlnschten Namen mit max 16 Buchstaben nur speichern wenn man die Schnittstelle uumlber den Computer benutzt
Bei der Wahl eines Programms erscheint folgendes Fenster
Anzeige des Namens der dem Programm zugeordnet istUm auf die Anwendung einzuwirken stehen 3 Auswahlmoumlglichkeiten zur Verfuumlgung
Das Programm wird im Speicher des AC 26N gespeichert
Das Programm wird geloumlscht
Das Programm wird geladen und ist bereit fuumlr die Benutzung
Save
Del
Load
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
37
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
38
BESCHREIBUNG DES MENUumlFENSTERS X-Over
Dieses Fenster erlaubt fuumlr jeden Ausgang einen Bassdurchgangsfilter einen Hochdurchgangsfilter oder mittels Kombination von beiden einen Banduumlbergangsfilter zu waumlhlenDer Filter ist ein Linkwitz-Riley wo man die Neigung von 12 dBoct 24dBoct oder 48 dBoct und die entsprechende Schnittfrequenz auswaumlhlen kann
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) AUSGANGSKANAumlLE
Die Steckverbinder am Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) FILTER CROSSOVERDen Filter nach Bedarf waumlhlen Man kann folgendes auswaumlhlen
Dis Kein Filter aktiviert
HP Hochdurchgangsfilter nur den Teil des Audiosignals durchlassen der uumlber der Schnittfrequenz liegt
LP Bassdurchgangsfilter nur den Teil des Audiosignals durchlassen der unter der Schnittfrequenz liegt
Filter-Konfiguration Tiefpass Hochpass
Nichts Dis Dis
Hochpass HP Dis
Tiefpass Dis LP
Bandpass HP LP
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
c) DAumlMPFUNGSNEIGUNGDie Daumlmpfungsneigung des Audiosignals auf der Basis der Verringerung auswaumlhlen die man erreichen moumlchte Je houmlher die Daumlmpfungsneigung bei gleicher Schnittfrequenz desto groumlszliger ist die Signalauswahl Man kann folgendes waumlhlen
12 entsprechend 12 dboct
24 entsprechend 24 dboct
48 entsprechend 48 dboct
d) SCHNITTFREQUENZErlaubt die Durchgangsfrequenz der niederen Frequenzen (Bassdurchgangsfilter) oder der hohen Frequenzen (Hochdruchgangsfilter) einzustellenDie Auswahl des Schnitts bezieht sich auf die Wiedergabe die man erreichen moumlchteDie benutzte Maszligeinheit ist Hz
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
BESCHREIBUNG DES MENUumlFENSTERS Matrix
Erlaubt fuumlr jeden Ausgang das Eingangssignal zu waumlhlen das als Quelle benutzt werden soll
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) AUSGANGSKANAumlLEIdentifizierung des einzustellenden Ausgangskanals
b) IDENTIFIZIERUNG DER EINGAumlNGEDen Signaltyp auswaumlhlen der nach eigener Anforderung jedem einzelnen Ausgang zugeordnet werden soll Man kann folgendes waumlhlen
In A Das Signal wird dem Eingang A zugeordnet
In B Das Signal wird dem Eingang B zugeordnet
In A+B Zuordnung der a lgebra ischen Summe der be iden Eingangssignale A und B
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
BESCHREIBUNG DES MENUumlFENSTERS Option
Erlaubt die Anzeige der Systemeinstellungen wie die Zuordnung der Ein- und Ausgaumlnge Daumlmpfung Displaykontrast und Firmware-Version
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B Src
Diese Option erlaubt die Einstellung des Audio-Signaltyps am Eingang
Analoge Audiosignale (Eingaumlnge A und B)
Digitale Audiosignale (Eingang AESEBU)
DigOut Src
An In =Audiosignale an den analogen Eingaumlngen
Dig In =Audiosignale am digitalen Eingang
OUT 1-2 =Audiosignale an den Ausgaumlngen 1 und 2
OUT 3-4 =Audiosignale an den Ausgaumlngen 3 und 4
OUT 5-6 =Audiosignale an den Ausgaumlngen 5 und 6
Input Mode
An In
Dig In
Indip =
Linked =
Diese Option erlaubt die Audioquelle zu waumlhlen die fuumlr den Steckverbinder AESEBU OUT (digitaler Ausgang) bestimmt ist
Erlaubt die Eingaumlnge zu konfigurieren
Sie sind unabhaumlngig und selbststaumlndig sie unterliegen keinen Verpflichtungen untereinander Sie sind verbunden und funktionieren im Stereo-Modus
Die Kompressoren Filter Verzoumlgerungen die Lautstaumlrke sind bei beiden Kanaumllen identisch
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
39
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
40
Atten PadZeigt an wie der Wahlschalter -6 dB auf der Ruumlckseite eingestellt ist [Ref 5] Dieser Wahlschalter muss aktiviert werden wenn das Level an den analogen Eingaumlngen zu hoch ist Der Wahlschalter wird uumlber die Taste aktiviert im Menuuml gibt es nur eine Anzeige
0dB = Wahlschalter nicht aktiviert
-6dB = Wahlschalter aktiviert
Contrast
10 heller 60 dunkler 100
Fw Vers
Die Eingangssignale sind dieselben wie die Eingangsquelle
Die Eingangssignale werden vom internen Prozessor um -6 dB gedaumlmpft
Erlaubt den Kontrast des LCD-Displays einzustellen um den Unterschied der Helligkeit auf den Installationsort auszurichten Ein deutlicheres Display erlaubt auf korrekte und schnelle Weise innerhalb der Menuumls zu surfenDie Hersteller-Einstellung am Ausgang liegt bei 60
Zeigt die Firmware-Version des Prozessors an
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
41
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
42
TECHNISCHE DATEN
Antwort in FrequenzDynamische GammaCMMRCrosstalkDistorsion
ProzessorFrequenz der DatenausarbeitungAnaloge Converter Verzoumlgerung der VerteilungSpeicherung der Konfigurationen
DisplayTastenBedienungen
Analoger Eingang ndeg2 x XLR (3-poliger Female Stecker)Impedanz des Eingangs gt10KOhmMaximales Level +21dBu ohne PAD
+27dBu bei PAD
Impedanz des Ausgangs 50OhmMaximales Level +21dBu Typ symmetrisch
Typ SPDIF-AESEBU (AES3)
Typ Entsprechend dem Standard des Eingang
Typ
Typ
NETZSPANNUNGABMESSUNGEN (BXHXT)GEWICHT
AUDIO-LEISTUNGEN+- 01dB (20 to 30kHz)116dB typgt 60dB (50 to 10kHz)lt -100dB0002 (1kHz +4dBu)
DIGITALE AUDIO-LEISTUNGEN DSP 2856-bit 48KHz24-bit BURR BROWN15ms32 preset
KONTROLLEN LCD GrafikESC - MENU - FUNCTIONS SELECTIONENTER
EIN-AUSGAumlNGE
Analoger Ausgang ndeg6 x XLR (3-poliger Male Stecker)
Digitaler Eingang ndeg1x XLR (3-poliger female Stecker)
Digitaler Ausgang ndeg1x XLR (3-poliger Male Stecker)
Ein-Ausgang Rdnet ndeg2 x XLR RJ45 (kabel CAT 5) USB Typ B
KONTROLLPARAMETER AUDIOStaumlrke -80dB a +20dB step 01dBVerzoumlgerung Eingang 0 a 729mS step 01 mS
Ausgang 0 a 340mS step 01mSPhasenrotation 0deg - 180deg
KOMPRESSIONSchwelle -80dB a +20dB step 01dBVerhaumlltnis 11 a Inf1 step 001Staumlrke am Ausgang 0dB a 40dB step 01dBAnschlusszeit 1mS a 1000mS step 01mSReleasezeit 1mS a 1000mS step 01mSBeibehaltungszeit 1mS a 1000mS step 01mS
EQUALIZER12 Equalizer fuumlr jeden Ein- und Ausgang
PEQ (parametrischer) Hi-shelf Lo-sheftFrequenz 20Hz a 20KHz step 1HzStaumlrke -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (lediglich PEQ)
FILTER CROSSOVERFilter Linkwitz Riley
HP HochdurchgangsfilterLP Bassdurchgangsfilter
Neigung 12dBoct - 24dBoct - 48dBoctSchnittfrequenz 5Hz a 20KHz step 1Hz
Full-range 100-240Vac 50-60Hz430482x43x130mm 19Kg
AnmerkungenSpezifikationen unterliegen Aumlnderungen ohne Vorankuumlndigung
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
INTRODUCTIONAC26N est un processeur audio numeacuterique pour la gestion de leacutequipement audio conccedilu pour des installations fixes et mobiles Il fonctionne selon une technologie de pointe avec des processeurs agrave 2856bits et des convertisseurs ADDA agrave 24-bits hautes performances Les fonctions du processeur sont les niveaux dentreacutee et de sortie le deacutelai (delay) la polariteacute 12 bandes deacutegalisation par canal dentreacutee et de sortie diffeacuterentes seacutelections de croisement (crossover) et un limiteur hautes performances Le controcircle des filtres a une reacutesolution de 1Hz Les entreacutees et les sorties peuvent ecirctre programmeacutees en plusieurs configurations pour satisfaire tous les besoins AC26N peut ecirctre controcircleacute en temps reacuteel et tous les paramegravetres peuvent ecirctre configureacutes depuis le pupitre frontale et par ordinateur avec interface graphique intuitive accessible via le logiciel laquoDVA Networkraquo et une connexion de reacuteseau deacutedieacutee RDnet ou USBLa mise agrave jour du logiciel pour lUniteacute centrale et DSP par ordinateur portable permet de maintenir le dispositif actualiseacute Il est possible denregistrer et de rappeler 32 configurations preacute-eacutequipeacutees de configuration
Contenu de lemballage - AC26N - Mode demploi- CD logiciel- Cacircble dalimentation
Caracteacuteristiques- 2 entreacutees et 6 sorties avec adressage flexible- Entreacutee et sortie steacutereacuteo AESEBU adressables - DSP 2856-bit- Convertisseurs AD BURR BWOWN 24-bit hautes performances- Freacutequence de reacutesolution des filtres 1 Hz - 12 eacutegaliseurs parameacutetriques pour chaque entreacutee et sortie- 2 filtres de croisement par sortie avec pente seacutelectionnable agrave 122448dBoct- DRC agrave configuration multiple hautes performances pour configuration limiteur
compression pour chaque entreacutee et sortie- Niveau reacuteglable en dB polariteacute et deacutelai pour chaque entreacutee et sortie- Mise agrave jour du micrologiciel par lordinateur- Affichage graphique agrave cristaux liquides- 32 preacutereacuteglages enregistrables par lutilisateur- Interface USB pour le controcircle et la configuration par ordinateur- Interface RDnet permettant de controcircler jusquagrave 256 dispositifs agrave distance
PC
PC
RDNETcontrol(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FONCTIONS DE LA FACE AVANT
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
COMMANDES ET FONCTIONS1) AFFICHAGE
Laffichage graphique agrave cristaux liquides permet de visualiser et deacutediter les informations de lAC26N sans utiliser lordinateur Le contraste peut ecirctre configureacute dans le menu principal
2) MANETTE Functions Selector et Push EnterCe controcircle permet de se deacuteplacer de seacutelectionner et de modifier les paramegravetres dans les menus affichables agrave leacutecranRotation de la manette (Functions Selectors)- permet de se deacuteplacer sur les diffeacuterentes pages du menu - permet de modifier les paramegravetres seacutelectionneacutesPression de la manette (Push Enter)- permet de seacutelectionnervalider les paramegravetres
3) Bouton ESC Ce controcircle permet de quitter les menus afficheacutes ou de revenir agrave la visualisation preacuteceacutedente
4) Bouton Menu Ce controcircle permet dacceacuteder directement au menu principal
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
Fra
nccedilais
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
43
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
Fra
nccedilais
44
DVA Network
AC26N est eacutequipeacute dune interface de reacuteseau proprieacutetaire deacutenommeacutee RDNET au moyen de laquelle il est possible de sinterfacer agrave lordinateur agrave travers un peacuteripheacuterique (RDNET control)
Pour cela un protocole de communication a eacuteteacute deacuteveloppeacute avec lequel il est possible de recevoir et denvoyer les donneacutees ce branchement permet de faire le monitorage en temps reacuteel des paramegravetres du diffuseur comme puissance de sortie tempeacuterature de lamplificateur eacutetat du limiteur etc Il est aussi possible de seacutelectionner diffeacuterentes eacutegalisations ou den creacuteer de nouvelles et de reacutegler les niveaux de volume souhaiteacutes au moyen dun plug-in approprieacute
On conseille de teacuteleacutecharger gratuitement le logiciel DVA Network directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
DVA USB Manager
On conseille de teacuteleacutecharger gratuitement le logiciel DVA USB Manager directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
Le micrologiciel du module amplificateur peut ecirctre remis agrave jour par le port USBPour rendre cette mise agrave jour possible et facile un programme speacutecifique a eacuteteacute deacuteveloppeacute
DOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
CONNEXIONS DU PANNEAU ARRIEgraveRE
1586 75 141210 11 13 169 17
14) Connecteur ldquo USBrdquoCe connecteur USB (type B) permet de connecter le processeur agrave un ordinateur pour le controcircle et la mise agrave jour du micrologiciel via un programme deacutedieacute (DVA Network)
15) PRISE DALIMENTATION MAINSPermet la connexion du cacircble dalimentation fourni de seacuterie
16) PORTE-FUSIBLE FUSELogement pour fusible de ligne
17) INTERRUPTEUR GENERAL POWERLinterrupteur permet de mettre en marche ou deacuteteindre le controcircleur audio
COMMANDES ET FONCTIONS
5) SELECTEUR ldquo-6dBrdquoLe seacutelecteur permet de reacuteduire de 6dB les niveaux dentreacutee analogiques XLR [6] tout en compensant les niveaux eacuteleveacutes de sortie des meacutelangeurs ou dautres dispositifs audio Quand la barre du niveau de signal des entreacutees sur laffichage [1] reste au maximum cela indique que le niveau du signal entrant est eacuteleveacute Il est alors conseilleacute dutiliser latteacutenuation -6dBIl est possible de veacuterifier quand le seacutelecteur est activeacute par le menu Option
6) CONNECTEURS DENTREE ldquoArdquo ET ldquoBrdquoEntreacutees eacutequilibreacutees au niveau de la ligneIls sont en mesure daccepter des connecteurs XLR macircles
7) CONNECTEURS DE SORTIE ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo ET ldquo6rdquoSorties eacutequilibreacutees au niveau de la ligne Ils sont en mesure daccepter des connecteurs XLR femelles
Prendre garde agrave brancher convenablement les sorties sur les diffuseurs ou les amplificateurs en fonction des configurations de chaque canal pour eacuteviter des deacutegacircts et des problegravemes de fonctionnement
Section ldquoAESEBUrdquo
8) CONNECTEUR DENTREE INOutre les entreacutees audio analogiques une entreacutee audio numeacuterique SPDIF-AESEBU (AES3) a eacuteteacute preacutevue et peut ecirctre seacutelectionneacutee par le menu de setupLentreacutee requiert une connexion eacutequilibreacutee en utilisant un connecteur XLR avec un cacircble agrave 3 conducteurs de 110ohm torsadeacute
9) CONNECTEUR DE SORTIE OUTCe connecteur permet de relancer le signal audio dans les entreacutees analogiques ou numeacuteriques ou sur les sorties La source doit ecirctre reacutegleacutee par le menu OptionLa connexion sera conforme agrave la mecircme norme que lentreacutee [reacutef8]
Section ldquoRDNETrdquo
10) CONNECTEUR DENTREE DATA INPUTConnecteur RJ45 entreacutee de donneacutees
11) CONNECTEUR DE SORTIE DATA LINKConnecteur RJ45 sortie de donneacutees pour la connexion de seacuterie en cascade
12) VOYANT LUMINEUX ONCe voyant de couleur verte sallume uniquement quand lAC26N a reconnu et est connecteacute agrave luniteacute principale RDNET par lordinateur
13) VOYANT LUMINEUX ACTIVECe voyant de couleur jaune clignote quand une transmission des donneacutees est active entre RDNET et le dispositif
PUSH
P SHU
SHPU
P SHU
PUSH
CONNEXIONS
Audio analogiquesLes connexions eacutequilibreacutees permettent de reacuteduire au minimum le bruit provoqueacute par les cacircbles et dutiliser de longs cacircblesCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLe connecteur XLR doit ecirctre brancheacute avec la broche 1 agrave la masse la broche 2 au chaud (+) et la broche 3 au froid (-) En cas de cacircble blindeacute brancher le blindage agrave la broche 1Les cacircbles de connexion XLR-XLR et XLR-Jack14(63mm) peuvent semployer pour la connexion agrave lAC26N
12
3
Entreacutee
Entreacutee
XLR - femme
XLR - femme
1 2
3
Sortie
Sortie
XLR - Macircle
XLR - Macircle
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2 = Point chaudPhase +VE
Broche 3 =Point froidPhase -VE
Broche 3 =Point froidPhase -VE
Anneau
Manchon
Pointe Point chaudPhase +VE
Anneau = Point froidPhase -VE
ManchonB Masselindeacute
Pointe
Les connexions deacuteseacutequilibreacutees peuvent semployer mecircme si le bruit provoqueacute par les cacircbles augmente Les cacircbles ne peuvent deacutepasser 5m de longCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLes connexions deacuteseacutequilibreacutees peuvent abaisser le niveau du signal entrant de 6dB Pour remeacutedier agrave cet inconveacutenient il faut brancher la broche 3 agrave la masse mecircme si cela augmente le bruit
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
45
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
46
12
3
1 2
3
Pointe Manchon
Pointe = Signal
Broche 3 = Link to Pin 1
Broche 3 = Link to Pin 1
ManchonB Masselindeacute
Audio numeacuteriques (AESEBU)
AESEBU (protocole AES3) est une entreacutee eacutequilibreacutee isoleacutee eacutelectriquement agrave laide dun transformateur Elle permet demployer deux canaux audio dans un seul cacircble bipolaire blindeacute Les caracteacuteristiques du cacircble doivent ecirctre de 3 pocircles impeacutedance 100ohm torsadeacute et blindeacute avec connecteur XLR (AES3 standard)
RJ 45
|1|2|3|4|5|6|7|8|
RDnet
Chaque port RDNet des Control 2 et Control 8 peut ecirctre brancheacute agrave un maximum de 32 dispositifs compatibles placeacutes en cascade Dans lexemple suivant le port de luniteacute de controcircle RDNET CONTROL 2 est relieacute agrave lentreacutee DATA INPUT dun AC26N dont la sortie parallegravele DATA LINK est envoyeacutee agrave lentreacutee de lAC26N successif Dans lexemple [n] est un nombre compris entre 3 et 32 (limite maximale des dispositifs que lon peut relier agrave un sous-reacuteseau)
La longueur totale du cacircble CAT5 dun sous-reacuteseau NE peut PAS deacutepasser 900 megravetres
Le connecteur doit ecirctre relieacute comme 1 ndash disponible pour dautres fonctions (par exemple audio +) 2 ndash disponible pour dautres fonctions (par exemple audio )3 ndash disponible pour dautres fonctions (par exemple masse analogique)4 ndash masse numeacuterique5 ndash masse numeacuterique6 ndash disponible pour dautres fonctions (par exemple alimentation)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
MISE EN MARCHE
Lors de la mise en marche du dispositif linitialisation deacutebute et dure quelques secondes Leacutecran affiche le modegravele le logo et la barre de progression du chargement du programme
En fin de processus dinstallation leacutecran affiche la fenecirctre du menu Meters Pour connaicirctre les indications en deacutetail consulter le paragraphe DESCRIPTION FENETRE MENU Meters
LAC26N est precirct agrave lemploi
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION ET VISUALISATION
Pour entrer dans la fenecirctre du menu principal il faut pousser sur la touche MENU ( ) agrave lavant du dispositifDune page quelconque du menu en poussant sur la touche ESCrdquo ( ) on revient automatiquement sur la page-eacutecran preacuteceacutedente
MENU PRINCIPAL
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Le processeur contient six menus Ils montrent etou configurent les paramegravetres du systegravemeLes menus principaux sont
Meters Visualisation des niveaux des entreacutees et des sorties visualisation du programme utiliseacute et eacutetat mute rapide
Preset Meacutemoriser enregistrer et eacuteliminer les configurations du systegraveme
Matrix seacutelectionner les sorties en fonction du signal entrant
Ch Job configuration de chaque signal
X-Over configurer les freacutequences de coupure et les types de filtres pour chaque sortie
Option attribution des entreacutees et des sorties contraste daffichage la version du micrologiciel les entreacutees et dautres options
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
47
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
48
DESCRIPTION DE LA FENETRE MENU Metersrdquo
Cette fenecirctre permet de visualiser les configurations et leacutetat geacuteneacuteral des entreacutees et des sorties la version du programme utiliseacute son eacutetat et le mode de pilotage du systegraveme
Les menus et les options afficheacutees peuvent se seacutelectionner en tournant la manette ldquoFUNCTIONS SETECTORrdquo ( ) Pour avoir accegraves agrave linteacuterieur de la seacutelection il faut mettre le paramegravetre souhaiteacute en eacutevidence et pousser sur la manette ldquoPush Enterrdquo ( | ) Il faut en faire de mecircme pour seacutelectionner etou modifier les options dans les commandes du menu
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositifAvec des signaux dentreacutee numeacuteriques les indications ldquoArdquo et ldquoBrdquo correspondent agrave lentreacuteeEn tournant la manette ldquoFUNCTIONS SELECTORrdquo [2] on fait deacutefiler en mode cyclique les canaux dentreacutee de sortie et lindication de mute geacuteneacuteral (d) le canal seacutelectionneacute est mis en eacutevidence
b) BARRE DE NIVEAU DE COMPRESSIONMUTE CANAL
COMPRESSION DE SIGNALLa compression du signal est visualiseacutee par le deacutefilement de la barre de droite de haut en bas
MUTE Chaque canal peut ecirctre placeacute en mute Seacutelectionner le canal et pousser sur la manette ldquoPush Enterrdquo [2] pour valider le changement deacutetat Lindication du canal sera remplaceacutee par la lettre M et la barre sera totalement mise en eacutevidencePour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterations
c) BARRE DE NIVEAU DE SIGNALLindication du niveau de chaque canal est signaleacutee par le deacutefilement de la barre de gauche
d) MUTE GENERALIl est possible de mettre simultaneacutement toutes les entreacutees et les sorties en mute Tourner la manette ldquoFUNCTIONS SELECTORrdquo seacutelectionner la lettre M et pousser sur la manette Push EnterPour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterationsLe mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) MODES DE COMMANDEIl affiche le mode dutilisation etou les dispositifs qui sont relieacutes agrave lAC26N
Local = utilisation autonome Aucune connexion agrave un dispositif exteacuterieur
NET = relieacute directement au reacuteseau deacutedieacute RDNet et agrave lordinateur
USB = relieacute directement agrave un ordinateur par cacircble USB
f) INDICATION DETAT DE PARAMETRAGECette indication permet de constater si un ou plusieurs paramegravetre(s) du programme chargeacute aont eacuteteacute modifieacute(s) par rapport au dernier sauvetage
= programme dorigine
= programme avec des paramegravetres modifieacutes
g) PROGRAMME CONFIGURELe chiffre indique le programme chargeacute et utiliseacute par le systegraveme agrave lemplacement de sauvetage Consulter le menu de Preset pour de plus amples deacutetails
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
DESCRIPTION DE LA FENETRE MENU Ch Job
Cette fenecirctre permet dafficher la configuration de chaque canal
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) NIVEAU DU SIGNALIndique le gain du signal Laugmentation de lintensiteacute dun signal est libelleacutee en deacutecibel (dB) Le paramegravetre peut ecirctre seacutelectionneacute de -8000dB agrave +2000dB avec des pas de 001dB Une augmentation de 6dB est eacutegale approximativement au redoublement agrave leacutechelle lineacuteaire du niveau du signal sous tensionAvec un gain supeacuterieur agrave 0dB le signal est amplifieacute tandis quavec un gain infeacuterieur agrave 0dB le signal est atteacutenueacute
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
49
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
50
c) DELAI DU SIGNAL (DELAY)Le signal audio reproduit peut ecirctre retardeacute pour permettre lalignement acoustique Cela compense les diffeacuterentes positions des diffuseurs pendant linstallation et la reproduction sonore Il se libelle en mS Le paramegravetre peut ecirctre seacutelectionneacute de 00mS agrave 729mS avec un pas de 01mSPour aligner un signal audio il est possible dutiliser la formule suivante
Deacutelai = (GAPx1000)344
Deacutelai = ms (en millisecondes)GAP = distance du diffuseur du point de reacutefeacuterence (en megravetres)Vitesse du son = 344ms
d) MUTEChaque canal peut ecirctre placeacute en mute La mecircme commande peut ecirctre activeacutee dans la fenecirctre du menu meters NB Le mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) PhasePermet la rotation de phase de 180deg par rapport au signal entrantCette rotation permet loptimisation surtout des basses freacutequences dans les installations complexes
f) EGALISATIONCette commande ouvre la fenecirctre du menu deacutegalisation de chaque canal Elle sert surtout pour corriger une ou plusieurs freacutequences qui doivent ecirctre atteacutenueacutees ou augmenteacutees
M M
LAC26N gegravere 12 filtres par canal dentreacutee et sortie avec trois types de configurations diffeacuterentes - Leacutegaliseur PEQ (peaking equalizer) est ideacuteal pour identifier isoler et
corriger une seule plage de freacutequences bien deacutetermineacutee Toutes les freacutequences passent mais il augmente ou diminue uniquement celles autour de la freacutequence centrale pour une bande preacutecise et un gain deacutefini
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessus de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessous de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
f Numeacuterotation des 12 filtres disponibles pour cette entreacutee ou cette sortie1
f Le type de filtre est afficheacute 2
Dis Deacutesactiveacute (absent)
PEQ Peaking equlizer
Sh H Filtre high-shelf
Sh L Filtre high-shelf
Exemples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
REMARQUELe paramegravetre Bw deacutetermine le champ de freacutequences adjacent agrave la freacutequence configureacutee ougrave est activeacute le filtre Plus la valeur Bw est eacuteleveacutee plus vaste est le champ de freacutequences (1Bw=1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONCette commande ouvre la fenecirctre du menu de compression de chaque canal
g1) TresholdIdentifie le seuil ougrave commence le rapport de compression La valeur de base 11
g2) RatioIndique le rapport de conversion entre le signal entrant et le signal sortant
g3) Post Gain Attach Release HoldCes donneacutees deacutependent du rapport de conversion que lon veut obtenir - Post Gain est le gain de sortie- Attack est le temps dattaque - Release est le temps de relacircchement- Hold est le temps de maintien
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
52
DESCRIPTION DE LA FENETRE MENU Preset
Cette fenecirctre permet de meacutemoriser jusquagrave 32 configurations dans lAC26NLe fabricant fournit le systegraveme avec un programme configureacute et enregistreacute en position 0 et non susceptible deacutecrasement
032 Elle indique lemplacement de sauvetage de la configurationCe numeacutero apparaicirct dans la fenecirctre Meters en position (g) A tout moment le programme utiliseacute peut ecirctre afficheacute par lutilisateur
Empty Preset Cest le nom qui est associeacute au numeacutero de lemplacement quand aucune configuration (vide) nest enregistreacutee
Local preset Local preset est le nom qui est associeacute au numeacutero de lemplacement quand on enregistre une configuration NB = Il est possible denregistrer une configuration avec lenom souhaiteacute de 16 lettres tout au plus agrave condition que lonutilise linterface via lordinateur
Le nom du programme assigneacute est indiqueacutePour toucher agrave lapplication 3 choix soffrent agrave vous
Save Le programme est enregistreacute en meacutemoire de lAC26N
Del Le programme est effaceacute
Load Le programme est chargeacute et precirct agrave lemploi
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
51
DESCRIPTION DE LA FENETRE MENU X-Over
Cette fenecirctre permet de seacutelectionner un filtre passe bas un filtre passe haut ou par la combinaison des deux de creacuteer un filtre passe bande pour chaque sortieLe filtre actif est un Linkwitz-Riley qui permet de seacutelectionner la pente de 12dBoct 24dBoct ou 48dBoct et sa freacutequence de coupure
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) CANAUX DE SORTIE
Les connecteurs de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) FILTRE CROSSOVERSeacutelectionner le filtre selon les besoins Il est possible de seacutelectionner
Dis Aucun filtre activeacute
HP Filtre passe-haut laisse passer uniquement la partie de signal audio supeacuterieure agrave la freacutequence de coupure
LP Filtre passe-bas laisse passer uniquement la partie de signal audio infeacuterieure agrave la freacutequence de coupure
Configuration du filtre Passe-haut Passe-bas
Rien Dis Dis
Passe-haut HP Dis
Passe-bas Dis LP
Passe-bande HP LP
12dBoct
24dBoct
Hz
dB
Ga
in 48dBoct
12dBoct
24dBoct
Hz
dB
Ga
in
48dBoct
c) PENTE DATTENUATIONSeacutelectionner la pente datteacutenuation du signal audio en fonction de la diminution que lon veut obtenir Plus la pente datteacutenuation est eacuteleveacutee agrave eacutegaliteacute de freacutequence de coupure plus eacuteleveacutee sera la seacutelection du signal Il est possible de seacutelectionner
12 correspond agrave 12dboct
24 correspond agrave 24dboct
48 correspond agrave 48dboct
d) FREQUENCE DE COUPUREElle permet de reacutegler la freacutequence de passage des freacutequences infeacuterieures (filtre passe-bas) ou des freacutequences supeacuterieures (filtre passe-haut) uniquementLe choix de la coupure deacutepend de la reproduction que lon veut obtenirLuniteacute de mesure utiliseacutee est lHz
Hz
Hz
dB
dB
Ga
in
f0
f0
0dB0dB
0dB
-6dB
freacutequence
freacutequence
freacutequence
freacutequence
Ga
in
f0
0dB
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
53
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
54
DESCRIPTION DE LA FENETRE MENU Matrix
Elle permet de seacutelectionner le signal entrant agrave utiliser comme source pour chaque sortie
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) CANAUX DE SORTIEIdentification du canal sortant agrave reacutegler
b) IDENTIFICATIONS DES ENTREESSeacutelectionner le type de signal agrave associer agrave chaque sortie en fonction des besoins Il est possible de seacutelectionner
In A Le signal entrant A est associeacute
In B Le signal entrant B est associeacute
In A+B La somme algeacutebrique des deux signaux entrants A et B est associeacutee
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
DESCRIPTION DE LA FENETRE MENU Option
Permet dafficher les reacuteglages du systegraveme comme lassignation des entreacutees et des sorties latteacutenuation le contraste de laffichage et la version du logiciel
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcCette option permet de reacutegler le type de signal audio entrant
An In =signaux audio analogiques (entreacutees ldquoArdquo et ldquoBrdquo)
Dig In =signaux audio numeacuteriques (entreacutee AESEBU)
DigOut SrcCette option permet de seacutelectionner la source audio qui sera adresseacutee sur le connecteur AESEBU OUT (sortie numeacuterique)
An In = signaux audio des entreacutees analogiques
Dig In =signaux audio sur lentreacutee numeacuterique
OUT 1-2 = signaux audio sur les sorties 1 et 2
OUT 3-4 = signaux audio sur les sorties 3 et 4
OUT 5-6 = signaux audio sur les sorties 5 et 6
Input ModePermet de configurer les entreacutees
Indip = sont indeacutependantes et autonomes Ne sont soumises agrave aucun type de lien
Linked = sont unies et fonctionnent en mode steacutereacuteo Les compresseurs les filtres les deacutelais le volume sont identiques pour les deux canaux
Atten PadIndique le mode de reacuteglage du seacutelecteur ldquo-6dBrdquo placeacute agrave larriegravere [reacutef 5] Il faut activer ce seacutelecteur quand les niveaux dentreacutee analogiques sont trop eacuteleveacutes Le seacutelecteur sactive uniquement par le bouton Dans le menu il sagit dune simple visualisation
0dB = seacutelecteur non activeacute Les signaux dentreacutee sont identiques agrave la source entrante
-6dB = seacutelecteur activeacute Les signaux entrants sont atteacutenueacutes de -6dB par le processeur interne
ContrastIl permet de reacutegler le contraste de laffichage agrave cristaux liquides pour compenser la diffeacuterence de luminositeacute avec le lieu dinstallation Une plus grande clarteacute de laffichage permet de naviguer convenablement et rapidement dans les menusLe reacuteglage agrave la sortie de lusine du fabricant est de 60
10 plus clair 60 plus fonceacute 100
Fw VersIndique la version du logiciel du processeur
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
55
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
56
DONNES TECHINIQUES
PERFORMANCES AUDIOReacuteponse en freacutequence +- 01dB (20 to 30kHz)Plage dynamique 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsion 0002 (1kHz +4dBu)
PERFORMANCES AUDIO NUMERIQUES Processeur DSP 2856-bit Freacutequence de traitement des donneacutees 48KHzConvertisseurs analogiques 24-bit BURR BROWNDeacutelai de propagation 15msMeacutemorisations des configurations 32 preset
CONTROLES Affichage LCD graficoBoutonsCommandes ESC - MENU - FUNCTIONS SELECTION
ENTERENTREESSORTIESEntreacutee analogique ndeg2 x XLR (3 broches femelle)
Impeacutedance dentreacutee gt10KOhmNiveau maximum +21dBu senza PAD
+27dBu con PADSortie analogique ndeg6 x XLR (3 broches macircle )
Impeacutedance de sortie 50OhmNiveau maximum +21dBuType Balanceacute
Entreacutee numeacuterique ndeg1x XLR (3 broches femelle)Type SPDIF-AESEBU (AES3)
Sortie numeacuterique ndeg1x XLR (3 broches macircle )Type conforme agrave la norme de lentreacutee
EntreacuteesSortie Rdnet ndeg2 x XLR RJ45 (cacircble CAT 5)USB Type B
PARAMETRES DE CONTROLE DU SONGain -80dB a +20dB eacutetape 01dBDeacutelai Entreacutee 0 a 729mS eacutetape 01 mS
Sortie 0 a 340mS eacutetape 01mSRotation de phase 0deg - 180deg
COMPRESSIONSeuil -80dB a +20dB eacutetape 01dBRapport 11 a Inf1 eacutetape 001Gain agrave la sortie 0dB a 40dB eacutetape 01dBTemps dattaque 1mS a 1000mS eacutetape 01mSTemps de relacircchement 1mS a 1000mS eacutetape 01mSTemps de maintien 1mS a 1000mS eacutetape 01mS
EGALISEURS12 eacutegaliseurs pour chaque entreacutee et sortieType PEQ (parameacutetrique) Hi-shelf Lo-sheft
Freacutequence 20Hz a 20KHz eacutetape 1HzGain -30dB a +15dB eacutetape 001dBBande 005dB a 2dB eacutetape 001dB (uniquement pour PEQ)
FILTRES CROSSOVERFiltre Linkwitz Riley
Type HF high-shelfLF low-shelf
Pente 12dBoct - 24dBoct - 48dBoctFreacutequence de coupure 5Hz a 20KHz eacutetape 1Hz
ALIMENTATION Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)POIDS 19Kg
Remarques Speacutecifications sujettes agrave modifications sans preacuteavis
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
2 VIE ATTIVO2 WAY ACTIVE
3 VIE PASSIVO3 WAY PASSIVE
L
L
A
A
HIGH L
MID L
LOW HIGHMID RHIGHMID L
LOW L
HIGH R
MID R
LOW R
R
R
B
B
1
1
2
2
3
3
456
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
Menu Matrix configurationMatrix
57 58
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
EROUIG ATRIX TNM
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
OU
TP
UT
1
OU
TP
UT
2
OU
TP
UT
3
OU
TP
UT
4
OU
TP
UT
5
OU
TP
UT
6
AE
S-E
BU
OU
TP
UT
INP
UT
A
AE
S-E
BU
INP
UT
INP
UT
B
D D D D D D
D D
A A A A A A
A SA
MP
LE
RA
TE
CO
NV
A
LIN
KA
BL
E
SC
HE
MA
A B
LO
CC
HI -
BL
OC
K D
IAG
RA
MB
LO
CK
SC
HA
LT
BIL
D -
SC
HE
MA
S F
ON
CT
ION
NE
LS
LINE ARRAY SUB MONO ATTIVO
LINE ARRAY SUB MONO ACTIVEINGRESSI - INPUT
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
L
L
L
A
A
A
AESEBU IN
AESEBU IN
AESEBU IN
AESEBU OUT
AESEBU IN
AESEBU IN
AESEBU OUT
R
R
R
LR
B
B
B
123456
HIGHMID L
HIGHMID L HIGHMID R
HIGHMID R
LOW L LOW R
LAYER
DISPLAY MEMORY
FADER MODE
LAYER
DISPLAY MEMORY
FADER MODE
Ingresso ANALOGICO
ANALOG Input
Collegamento in cascata
Link connections
Ingresso DIGITALE
DIGITAL inputA B
BALANCED AUDIO INPUTS
-6dB
PUSH PUSH
IN OUT
AES EBUPUSH
Oppure
or
Oppure
or
Menu Option configurationOption
Menu Option configurationOption Menu Option configurationOption
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type Analog
AES out An In
Input type Analog
AES out An In
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
59 60
InA-B Src Dig InInA-B Src Dig InInA-B Src An InInA-B Src An In
frequenzaHz
dB
Gu
ad
ag
no
60 200 2800
0dB0dB
-6dB
Esempio di un sistema a 3-vie
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
Out 1 Out 2 Out 3
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Esempio di un sistema a 3-vie
61 62
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
26NAC 26NAC
R TE
DO
R
MO LEU O R CE S
E O TR L A
S O
O C ND I P
P hsuernE t
o su cti nF nel rS e tc o
E CSME UN
IGCHTE OL SN EOBd
ocaL l
M
0
484
467
430
44
31
75
12
7
DIMENSIONI DIMENSIONSABMESSUNGEN DIMENSIONS
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziertBei den digitalen Eingangssignalen entspricht die Angabe A und B dem EingangDreht man den Drehgriff FUNCTIONS SELECTOR [2] durchlaumluft man zyklisch die Ein- und Ausgangskanaumlle und die Angabe Mute allgemein (d) der ausgewaumlhlte Kanal wird hervorgehoben
b) BALKEN FUumlR DAS KOMPRESIONSLEVELMUTE KANAL
SIGNALKOMPRESSIONDie Signalkompression wird durch das Gleiten des rechten Balkens von oben nach unten angezeigt
MUTE Jeder einzelne Kanal kann auf Mute gestellt werden Den Kanal auswaumlhlen und den Drehgriff Push Enter [2] druumlcken um die Aumlnderung des Status zu bestaumltigen Die Angabe des Kanals wird durch den Buchstaben M ersetzt und der Balken wird komplett hervorgehobenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werden
c) BALKEN DES SIGNALLEVELSDie Anzeige des Levels jedes einzelnen Kanals wird durch das Gleiten des linken Balkens angezeigt
d) MUTE ALLGEMEINEs ist moumlglich alle Ein- und Ausgaumlnge gleichzeitig auf Mute zu schalten Den Drehgriff FUNCTIONS SELECTOR drehen den Buchstaben M waumlhlen und dann den Drehgriff Push Enter druumlckenUm die normale Funktion wieder aufzunehmen muumlssen vorherige Schritte wiederholt werdenDie allgemeine Stummschaltung hat eine houmlhere Prioritaumlt als die Stummschaltung der einzelnen Kanaumlle
e) ANSTEUERUNGSARTENEs wird angezeigt wie AC26N benutzt wird undoder an welchen Vorrichtungen es angeschlossen ist
= Benutzung stand-alone Kein Anschluss an einer externen Vorrichtung
= Direkt am Netz RDnet und am Computer angeschlossen
= Uumlber USB-Kabel direkt am Computer angeschlossen
f) ANZEIGE DES STATUS DER EINSTELLUNGENHier wird angezeigt ob einer oder mehrere Parameter des geladenen Programms im Vergleich zur letzten Speicherung veraumlndert wurden
Original-Programm
Programm mit veraumlnderten Parametern
g) EINGESTELLTES PROGRAMMDie Nummer zeigt das vom System geladene und benutzte Programm in Bezug auf die Lokalisierung der Speicherung an Fuumlr weitere Details beziehen Sie sich bitte auf das Menuuml Preset
Local
NET
USB
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
BESCHREIBUNG DES MENUumlFENSTERS Ch Job
Dieses Fenster erlaubt die Anzeige der Konfiguration jedes einzelnen Kanals
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) EIN- UND AUSGANGSKANAumlLEDie Steckverbinder am Ein- und Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) SIGNALLEVELZeigt die Signalstaumlrke an Das Ansteigen der Signalintensitaumlt wird in Dezibel (dB) ausgedruumlckt Der Parameter kann zwischen -8000 dB und +2000 dB in Schritten von 001 dB ausgewaumlhlt werden Ein Anstieg von 6 dB ist fast gleich eine Verdoppelung in linearer Skala des Spannungswertes des SignalsBei einer Staumlrke von 0 dB wird das Signal verstaumlrkt waumlhrend es ein einer Staumlrke von weniger als 0 dB abgeschwaumlcht wird
c) VERZOumlGERUNG DES SIGNALS (DELAY)Das wiedergegebene Audio-Signal kann verzoumlgert werden um die akustische Ausrichtung zu erlauben Dies gleicht die verschiedenen Positionen der Lautsprecher bei der Installation und Klangwiedergabe aus und wird in mS ausgedruumlckt Der Parameter kann zwischen 00 mS und 729 mS in Schritten von 01mS ausgewaumlhlt werden
Um ein Audiosignal auszurichten kann folgende Formel benutzt werden
Verzoumlgerung = GAPx1000)344
Verzoumlgerung = mS (in Millisekunden ausgedruumlckt)GAP = Abstand des Lautsprechers vom Referenzpunkt (in Metern ausgedruumlckt)Klanggeschwindigkeit = 344 ms
d) MUTEJeder einzelne Kanal kann auf Mute gestellt werden Derselbe Befehl kann im Fenster des Menuumls Meters aktiviert werden PS Die al lgemeine Stummschaltung hat eine houmlhere Priori taumlt als die Stummschaltung der einzelnen Kanaumlle
e) PHASEErlaubt die Phasenrotation um 180deg zum EingangssignalDiese Rotation erlaubt vor Allem die Optimierung der niederen Frequenzen bei komplexen Installationen
f) ENTZERRUNGENDieser Befehl oumlffnet das Menuumlfenster fuumlr die Entzerrung des einzelnen Kanals Er wird vor Allem benutzt um eine oder mehrere Frequenzen zu korrigieren die gedaumlmpft oder verstaumlrkt werden muumlssen
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
35
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
36
AC26N verwaltet 12 Filter fuumlr jeden einzelnen Ein- und Ausgangskanal mit drei verschiedenen Konfigurationen- Equalizer PEQ (peaking equalizer) ist ideal um nur ein bestimmtes Frequenzband
zu identifizieren zu isolieren und zu korrigieren Es gehen alle Frequenzen durch aber nur die um die mittlere Frequenz steigt und sinkt um eine bestimmte Bandbreite und eine bestimmte Staumlrke
- Equalizer High-Shelf geht alle Frequenzen durch aber die Frequenzen uumlber der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
- Equalizer Low-Shelf geht alle Frequenzen durch aber die Frequenzen unter der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
f Nummerierung der 12 verfuumlgbaren Filter fuumlr diesen Ein- oder Ausgang1
f2 Es wird der Filtertyp angezeigt
Dis Ausgeschaltet (nicht vorhanden)
PEQ Peaking equalizer
Sh H Filter High-Shelf
Sh L Filter Low-shelf
Beispiele PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
ANMERKUNGDer Parameter Bw legt das Frequenzfeld neben der eingestellten Frequenz fest wo der Filter aktiviert wird je houmlher der Bw-Wert desto houmlher das Frequenzfeld (1Bw=1 Oktave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filter High-Shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filter Low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) KOMPRESSIONDieser Befehl oumlffnet das Menuumlfenster fuumlr die Kompression des einzelnen Kanals
g1) TresholdIdentifiziert die Schwelle an der das Kompressionsverhaumlltnis beginnt Der Basiswert 11
g2) RatioIdentifiziert das Kompressionsverhaumlltnis zwischen dem Ein- und Ausgangssignal
g3) Post Gain Attach Release HoldDiese Daten entsprechen dem Kompressionsverhaumlltnis das man erreichen moumlchte
Post Gain ist der Gewinn am AusgangAttack ist die Anschlusszeit Release ist die ReleasezeitHold ist die Beibehaltungszeit
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
BESCHREIBUNG DES MENUumlFENSTERS Preset
Dieses Fenster erlaubt bis zu 32 Konfigurationen im AC26N zu speichernDer Hersteller liefert das System mit einem voreingestellten Programm das auf Position 0 gespeichert ist und nicht uumlberschrieben werden kann
032 Es zeigt die Lokalisierung der Speicherung der KonfigurationDiese Nummer erscheint auch im Fenster Meters auf der Position (g) Das benutzte Programm kann jederzeit vom Benutzer angezeigt werden
Empty Preset Es ist der Name der der Nummer der Lokalisierung zugeordnet wird wenn keine Einstellung gespeichert ist (leer)
Local preset Es i s t de r Name de r de r Nummer de r Loka l i s i e rung zugeordnet wird wenn eine Konfiguration gespeichert wird
ANMERKUNG = Man kann eine Einstellung mit dem gewuumlnschten Namen mit max 16 Buchstaben nur speichern wenn man die Schnittstelle uumlber den Computer benutzt
Bei der Wahl eines Programms erscheint folgendes Fenster
Anzeige des Namens der dem Programm zugeordnet istUm auf die Anwendung einzuwirken stehen 3 Auswahlmoumlglichkeiten zur Verfuumlgung
Das Programm wird im Speicher des AC 26N gespeichert
Das Programm wird geloumlscht
Das Programm wird geladen und ist bereit fuumlr die Benutzung
Save
Del
Load
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
37
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
38
BESCHREIBUNG DES MENUumlFENSTERS X-Over
Dieses Fenster erlaubt fuumlr jeden Ausgang einen Bassdurchgangsfilter einen Hochdurchgangsfilter oder mittels Kombination von beiden einen Banduumlbergangsfilter zu waumlhlenDer Filter ist ein Linkwitz-Riley wo man die Neigung von 12 dBoct 24dBoct oder 48 dBoct und die entsprechende Schnittfrequenz auswaumlhlen kann
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) AUSGANGSKANAumlLE
Die Steckverbinder am Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) FILTER CROSSOVERDen Filter nach Bedarf waumlhlen Man kann folgendes auswaumlhlen
Dis Kein Filter aktiviert
HP Hochdurchgangsfilter nur den Teil des Audiosignals durchlassen der uumlber der Schnittfrequenz liegt
LP Bassdurchgangsfilter nur den Teil des Audiosignals durchlassen der unter der Schnittfrequenz liegt
Filter-Konfiguration Tiefpass Hochpass
Nichts Dis Dis
Hochpass HP Dis
Tiefpass Dis LP
Bandpass HP LP
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
c) DAumlMPFUNGSNEIGUNGDie Daumlmpfungsneigung des Audiosignals auf der Basis der Verringerung auswaumlhlen die man erreichen moumlchte Je houmlher die Daumlmpfungsneigung bei gleicher Schnittfrequenz desto groumlszliger ist die Signalauswahl Man kann folgendes waumlhlen
12 entsprechend 12 dboct
24 entsprechend 24 dboct
48 entsprechend 48 dboct
d) SCHNITTFREQUENZErlaubt die Durchgangsfrequenz der niederen Frequenzen (Bassdurchgangsfilter) oder der hohen Frequenzen (Hochdruchgangsfilter) einzustellenDie Auswahl des Schnitts bezieht sich auf die Wiedergabe die man erreichen moumlchteDie benutzte Maszligeinheit ist Hz
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
BESCHREIBUNG DES MENUumlFENSTERS Matrix
Erlaubt fuumlr jeden Ausgang das Eingangssignal zu waumlhlen das als Quelle benutzt werden soll
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) AUSGANGSKANAumlLEIdentifizierung des einzustellenden Ausgangskanals
b) IDENTIFIZIERUNG DER EINGAumlNGEDen Signaltyp auswaumlhlen der nach eigener Anforderung jedem einzelnen Ausgang zugeordnet werden soll Man kann folgendes waumlhlen
In A Das Signal wird dem Eingang A zugeordnet
In B Das Signal wird dem Eingang B zugeordnet
In A+B Zuordnung der a lgebra ischen Summe der be iden Eingangssignale A und B
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
BESCHREIBUNG DES MENUumlFENSTERS Option
Erlaubt die Anzeige der Systemeinstellungen wie die Zuordnung der Ein- und Ausgaumlnge Daumlmpfung Displaykontrast und Firmware-Version
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B Src
Diese Option erlaubt die Einstellung des Audio-Signaltyps am Eingang
Analoge Audiosignale (Eingaumlnge A und B)
Digitale Audiosignale (Eingang AESEBU)
DigOut Src
An In =Audiosignale an den analogen Eingaumlngen
Dig In =Audiosignale am digitalen Eingang
OUT 1-2 =Audiosignale an den Ausgaumlngen 1 und 2
OUT 3-4 =Audiosignale an den Ausgaumlngen 3 und 4
OUT 5-6 =Audiosignale an den Ausgaumlngen 5 und 6
Input Mode
An In
Dig In
Indip =
Linked =
Diese Option erlaubt die Audioquelle zu waumlhlen die fuumlr den Steckverbinder AESEBU OUT (digitaler Ausgang) bestimmt ist
Erlaubt die Eingaumlnge zu konfigurieren
Sie sind unabhaumlngig und selbststaumlndig sie unterliegen keinen Verpflichtungen untereinander Sie sind verbunden und funktionieren im Stereo-Modus
Die Kompressoren Filter Verzoumlgerungen die Lautstaumlrke sind bei beiden Kanaumllen identisch
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
39
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
40
Atten PadZeigt an wie der Wahlschalter -6 dB auf der Ruumlckseite eingestellt ist [Ref 5] Dieser Wahlschalter muss aktiviert werden wenn das Level an den analogen Eingaumlngen zu hoch ist Der Wahlschalter wird uumlber die Taste aktiviert im Menuuml gibt es nur eine Anzeige
0dB = Wahlschalter nicht aktiviert
-6dB = Wahlschalter aktiviert
Contrast
10 heller 60 dunkler 100
Fw Vers
Die Eingangssignale sind dieselben wie die Eingangsquelle
Die Eingangssignale werden vom internen Prozessor um -6 dB gedaumlmpft
Erlaubt den Kontrast des LCD-Displays einzustellen um den Unterschied der Helligkeit auf den Installationsort auszurichten Ein deutlicheres Display erlaubt auf korrekte und schnelle Weise innerhalb der Menuumls zu surfenDie Hersteller-Einstellung am Ausgang liegt bei 60
Zeigt die Firmware-Version des Prozessors an
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
41
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
42
TECHNISCHE DATEN
Antwort in FrequenzDynamische GammaCMMRCrosstalkDistorsion
ProzessorFrequenz der DatenausarbeitungAnaloge Converter Verzoumlgerung der VerteilungSpeicherung der Konfigurationen
DisplayTastenBedienungen
Analoger Eingang ndeg2 x XLR (3-poliger Female Stecker)Impedanz des Eingangs gt10KOhmMaximales Level +21dBu ohne PAD
+27dBu bei PAD
Impedanz des Ausgangs 50OhmMaximales Level +21dBu Typ symmetrisch
Typ SPDIF-AESEBU (AES3)
Typ Entsprechend dem Standard des Eingang
Typ
Typ
NETZSPANNUNGABMESSUNGEN (BXHXT)GEWICHT
AUDIO-LEISTUNGEN+- 01dB (20 to 30kHz)116dB typgt 60dB (50 to 10kHz)lt -100dB0002 (1kHz +4dBu)
DIGITALE AUDIO-LEISTUNGEN DSP 2856-bit 48KHz24-bit BURR BROWN15ms32 preset
KONTROLLEN LCD GrafikESC - MENU - FUNCTIONS SELECTIONENTER
EIN-AUSGAumlNGE
Analoger Ausgang ndeg6 x XLR (3-poliger Male Stecker)
Digitaler Eingang ndeg1x XLR (3-poliger female Stecker)
Digitaler Ausgang ndeg1x XLR (3-poliger Male Stecker)
Ein-Ausgang Rdnet ndeg2 x XLR RJ45 (kabel CAT 5) USB Typ B
KONTROLLPARAMETER AUDIOStaumlrke -80dB a +20dB step 01dBVerzoumlgerung Eingang 0 a 729mS step 01 mS
Ausgang 0 a 340mS step 01mSPhasenrotation 0deg - 180deg
KOMPRESSIONSchwelle -80dB a +20dB step 01dBVerhaumlltnis 11 a Inf1 step 001Staumlrke am Ausgang 0dB a 40dB step 01dBAnschlusszeit 1mS a 1000mS step 01mSReleasezeit 1mS a 1000mS step 01mSBeibehaltungszeit 1mS a 1000mS step 01mS
EQUALIZER12 Equalizer fuumlr jeden Ein- und Ausgang
PEQ (parametrischer) Hi-shelf Lo-sheftFrequenz 20Hz a 20KHz step 1HzStaumlrke -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (lediglich PEQ)
FILTER CROSSOVERFilter Linkwitz Riley
HP HochdurchgangsfilterLP Bassdurchgangsfilter
Neigung 12dBoct - 24dBoct - 48dBoctSchnittfrequenz 5Hz a 20KHz step 1Hz
Full-range 100-240Vac 50-60Hz430482x43x130mm 19Kg
AnmerkungenSpezifikationen unterliegen Aumlnderungen ohne Vorankuumlndigung
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
INTRODUCTIONAC26N est un processeur audio numeacuterique pour la gestion de leacutequipement audio conccedilu pour des installations fixes et mobiles Il fonctionne selon une technologie de pointe avec des processeurs agrave 2856bits et des convertisseurs ADDA agrave 24-bits hautes performances Les fonctions du processeur sont les niveaux dentreacutee et de sortie le deacutelai (delay) la polariteacute 12 bandes deacutegalisation par canal dentreacutee et de sortie diffeacuterentes seacutelections de croisement (crossover) et un limiteur hautes performances Le controcircle des filtres a une reacutesolution de 1Hz Les entreacutees et les sorties peuvent ecirctre programmeacutees en plusieurs configurations pour satisfaire tous les besoins AC26N peut ecirctre controcircleacute en temps reacuteel et tous les paramegravetres peuvent ecirctre configureacutes depuis le pupitre frontale et par ordinateur avec interface graphique intuitive accessible via le logiciel laquoDVA Networkraquo et une connexion de reacuteseau deacutedieacutee RDnet ou USBLa mise agrave jour du logiciel pour lUniteacute centrale et DSP par ordinateur portable permet de maintenir le dispositif actualiseacute Il est possible denregistrer et de rappeler 32 configurations preacute-eacutequipeacutees de configuration
Contenu de lemballage - AC26N - Mode demploi- CD logiciel- Cacircble dalimentation
Caracteacuteristiques- 2 entreacutees et 6 sorties avec adressage flexible- Entreacutee et sortie steacutereacuteo AESEBU adressables - DSP 2856-bit- Convertisseurs AD BURR BWOWN 24-bit hautes performances- Freacutequence de reacutesolution des filtres 1 Hz - 12 eacutegaliseurs parameacutetriques pour chaque entreacutee et sortie- 2 filtres de croisement par sortie avec pente seacutelectionnable agrave 122448dBoct- DRC agrave configuration multiple hautes performances pour configuration limiteur
compression pour chaque entreacutee et sortie- Niveau reacuteglable en dB polariteacute et deacutelai pour chaque entreacutee et sortie- Mise agrave jour du micrologiciel par lordinateur- Affichage graphique agrave cristaux liquides- 32 preacutereacuteglages enregistrables par lutilisateur- Interface USB pour le controcircle et la configuration par ordinateur- Interface RDnet permettant de controcircler jusquagrave 256 dispositifs agrave distance
PC
PC
RDNETcontrol(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FONCTIONS DE LA FACE AVANT
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
COMMANDES ET FONCTIONS1) AFFICHAGE
Laffichage graphique agrave cristaux liquides permet de visualiser et deacutediter les informations de lAC26N sans utiliser lordinateur Le contraste peut ecirctre configureacute dans le menu principal
2) MANETTE Functions Selector et Push EnterCe controcircle permet de se deacuteplacer de seacutelectionner et de modifier les paramegravetres dans les menus affichables agrave leacutecranRotation de la manette (Functions Selectors)- permet de se deacuteplacer sur les diffeacuterentes pages du menu - permet de modifier les paramegravetres seacutelectionneacutesPression de la manette (Push Enter)- permet de seacutelectionnervalider les paramegravetres
3) Bouton ESC Ce controcircle permet de quitter les menus afficheacutes ou de revenir agrave la visualisation preacuteceacutedente
4) Bouton Menu Ce controcircle permet dacceacuteder directement au menu principal
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
Fra
nccedilais
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
43
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
Fra
nccedilais
44
DVA Network
AC26N est eacutequipeacute dune interface de reacuteseau proprieacutetaire deacutenommeacutee RDNET au moyen de laquelle il est possible de sinterfacer agrave lordinateur agrave travers un peacuteripheacuterique (RDNET control)
Pour cela un protocole de communication a eacuteteacute deacuteveloppeacute avec lequel il est possible de recevoir et denvoyer les donneacutees ce branchement permet de faire le monitorage en temps reacuteel des paramegravetres du diffuseur comme puissance de sortie tempeacuterature de lamplificateur eacutetat du limiteur etc Il est aussi possible de seacutelectionner diffeacuterentes eacutegalisations ou den creacuteer de nouvelles et de reacutegler les niveaux de volume souhaiteacutes au moyen dun plug-in approprieacute
On conseille de teacuteleacutecharger gratuitement le logiciel DVA Network directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
DVA USB Manager
On conseille de teacuteleacutecharger gratuitement le logiciel DVA USB Manager directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
Le micrologiciel du module amplificateur peut ecirctre remis agrave jour par le port USBPour rendre cette mise agrave jour possible et facile un programme speacutecifique a eacuteteacute deacuteveloppeacute
DOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
CONNEXIONS DU PANNEAU ARRIEgraveRE
1586 75 141210 11 13 169 17
14) Connecteur ldquo USBrdquoCe connecteur USB (type B) permet de connecter le processeur agrave un ordinateur pour le controcircle et la mise agrave jour du micrologiciel via un programme deacutedieacute (DVA Network)
15) PRISE DALIMENTATION MAINSPermet la connexion du cacircble dalimentation fourni de seacuterie
16) PORTE-FUSIBLE FUSELogement pour fusible de ligne
17) INTERRUPTEUR GENERAL POWERLinterrupteur permet de mettre en marche ou deacuteteindre le controcircleur audio
COMMANDES ET FONCTIONS
5) SELECTEUR ldquo-6dBrdquoLe seacutelecteur permet de reacuteduire de 6dB les niveaux dentreacutee analogiques XLR [6] tout en compensant les niveaux eacuteleveacutes de sortie des meacutelangeurs ou dautres dispositifs audio Quand la barre du niveau de signal des entreacutees sur laffichage [1] reste au maximum cela indique que le niveau du signal entrant est eacuteleveacute Il est alors conseilleacute dutiliser latteacutenuation -6dBIl est possible de veacuterifier quand le seacutelecteur est activeacute par le menu Option
6) CONNECTEURS DENTREE ldquoArdquo ET ldquoBrdquoEntreacutees eacutequilibreacutees au niveau de la ligneIls sont en mesure daccepter des connecteurs XLR macircles
7) CONNECTEURS DE SORTIE ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo ET ldquo6rdquoSorties eacutequilibreacutees au niveau de la ligne Ils sont en mesure daccepter des connecteurs XLR femelles
Prendre garde agrave brancher convenablement les sorties sur les diffuseurs ou les amplificateurs en fonction des configurations de chaque canal pour eacuteviter des deacutegacircts et des problegravemes de fonctionnement
Section ldquoAESEBUrdquo
8) CONNECTEUR DENTREE INOutre les entreacutees audio analogiques une entreacutee audio numeacuterique SPDIF-AESEBU (AES3) a eacuteteacute preacutevue et peut ecirctre seacutelectionneacutee par le menu de setupLentreacutee requiert une connexion eacutequilibreacutee en utilisant un connecteur XLR avec un cacircble agrave 3 conducteurs de 110ohm torsadeacute
9) CONNECTEUR DE SORTIE OUTCe connecteur permet de relancer le signal audio dans les entreacutees analogiques ou numeacuteriques ou sur les sorties La source doit ecirctre reacutegleacutee par le menu OptionLa connexion sera conforme agrave la mecircme norme que lentreacutee [reacutef8]
Section ldquoRDNETrdquo
10) CONNECTEUR DENTREE DATA INPUTConnecteur RJ45 entreacutee de donneacutees
11) CONNECTEUR DE SORTIE DATA LINKConnecteur RJ45 sortie de donneacutees pour la connexion de seacuterie en cascade
12) VOYANT LUMINEUX ONCe voyant de couleur verte sallume uniquement quand lAC26N a reconnu et est connecteacute agrave luniteacute principale RDNET par lordinateur
13) VOYANT LUMINEUX ACTIVECe voyant de couleur jaune clignote quand une transmission des donneacutees est active entre RDNET et le dispositif
PUSH
P SHU
SHPU
P SHU
PUSH
CONNEXIONS
Audio analogiquesLes connexions eacutequilibreacutees permettent de reacuteduire au minimum le bruit provoqueacute par les cacircbles et dutiliser de longs cacircblesCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLe connecteur XLR doit ecirctre brancheacute avec la broche 1 agrave la masse la broche 2 au chaud (+) et la broche 3 au froid (-) En cas de cacircble blindeacute brancher le blindage agrave la broche 1Les cacircbles de connexion XLR-XLR et XLR-Jack14(63mm) peuvent semployer pour la connexion agrave lAC26N
12
3
Entreacutee
Entreacutee
XLR - femme
XLR - femme
1 2
3
Sortie
Sortie
XLR - Macircle
XLR - Macircle
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2 = Point chaudPhase +VE
Broche 3 =Point froidPhase -VE
Broche 3 =Point froidPhase -VE
Anneau
Manchon
Pointe Point chaudPhase +VE
Anneau = Point froidPhase -VE
ManchonB Masselindeacute
Pointe
Les connexions deacuteseacutequilibreacutees peuvent semployer mecircme si le bruit provoqueacute par les cacircbles augmente Les cacircbles ne peuvent deacutepasser 5m de longCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLes connexions deacuteseacutequilibreacutees peuvent abaisser le niveau du signal entrant de 6dB Pour remeacutedier agrave cet inconveacutenient il faut brancher la broche 3 agrave la masse mecircme si cela augmente le bruit
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
45
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
46
12
3
1 2
3
Pointe Manchon
Pointe = Signal
Broche 3 = Link to Pin 1
Broche 3 = Link to Pin 1
ManchonB Masselindeacute
Audio numeacuteriques (AESEBU)
AESEBU (protocole AES3) est une entreacutee eacutequilibreacutee isoleacutee eacutelectriquement agrave laide dun transformateur Elle permet demployer deux canaux audio dans un seul cacircble bipolaire blindeacute Les caracteacuteristiques du cacircble doivent ecirctre de 3 pocircles impeacutedance 100ohm torsadeacute et blindeacute avec connecteur XLR (AES3 standard)
RJ 45
|1|2|3|4|5|6|7|8|
RDnet
Chaque port RDNet des Control 2 et Control 8 peut ecirctre brancheacute agrave un maximum de 32 dispositifs compatibles placeacutes en cascade Dans lexemple suivant le port de luniteacute de controcircle RDNET CONTROL 2 est relieacute agrave lentreacutee DATA INPUT dun AC26N dont la sortie parallegravele DATA LINK est envoyeacutee agrave lentreacutee de lAC26N successif Dans lexemple [n] est un nombre compris entre 3 et 32 (limite maximale des dispositifs que lon peut relier agrave un sous-reacuteseau)
La longueur totale du cacircble CAT5 dun sous-reacuteseau NE peut PAS deacutepasser 900 megravetres
Le connecteur doit ecirctre relieacute comme 1 ndash disponible pour dautres fonctions (par exemple audio +) 2 ndash disponible pour dautres fonctions (par exemple audio )3 ndash disponible pour dautres fonctions (par exemple masse analogique)4 ndash masse numeacuterique5 ndash masse numeacuterique6 ndash disponible pour dautres fonctions (par exemple alimentation)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
MISE EN MARCHE
Lors de la mise en marche du dispositif linitialisation deacutebute et dure quelques secondes Leacutecran affiche le modegravele le logo et la barre de progression du chargement du programme
En fin de processus dinstallation leacutecran affiche la fenecirctre du menu Meters Pour connaicirctre les indications en deacutetail consulter le paragraphe DESCRIPTION FENETRE MENU Meters
LAC26N est precirct agrave lemploi
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION ET VISUALISATION
Pour entrer dans la fenecirctre du menu principal il faut pousser sur la touche MENU ( ) agrave lavant du dispositifDune page quelconque du menu en poussant sur la touche ESCrdquo ( ) on revient automatiquement sur la page-eacutecran preacuteceacutedente
MENU PRINCIPAL
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Le processeur contient six menus Ils montrent etou configurent les paramegravetres du systegravemeLes menus principaux sont
Meters Visualisation des niveaux des entreacutees et des sorties visualisation du programme utiliseacute et eacutetat mute rapide
Preset Meacutemoriser enregistrer et eacuteliminer les configurations du systegraveme
Matrix seacutelectionner les sorties en fonction du signal entrant
Ch Job configuration de chaque signal
X-Over configurer les freacutequences de coupure et les types de filtres pour chaque sortie
Option attribution des entreacutees et des sorties contraste daffichage la version du micrologiciel les entreacutees et dautres options
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
47
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
48
DESCRIPTION DE LA FENETRE MENU Metersrdquo
Cette fenecirctre permet de visualiser les configurations et leacutetat geacuteneacuteral des entreacutees et des sorties la version du programme utiliseacute son eacutetat et le mode de pilotage du systegraveme
Les menus et les options afficheacutees peuvent se seacutelectionner en tournant la manette ldquoFUNCTIONS SETECTORrdquo ( ) Pour avoir accegraves agrave linteacuterieur de la seacutelection il faut mettre le paramegravetre souhaiteacute en eacutevidence et pousser sur la manette ldquoPush Enterrdquo ( | ) Il faut en faire de mecircme pour seacutelectionner etou modifier les options dans les commandes du menu
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositifAvec des signaux dentreacutee numeacuteriques les indications ldquoArdquo et ldquoBrdquo correspondent agrave lentreacuteeEn tournant la manette ldquoFUNCTIONS SELECTORrdquo [2] on fait deacutefiler en mode cyclique les canaux dentreacutee de sortie et lindication de mute geacuteneacuteral (d) le canal seacutelectionneacute est mis en eacutevidence
b) BARRE DE NIVEAU DE COMPRESSIONMUTE CANAL
COMPRESSION DE SIGNALLa compression du signal est visualiseacutee par le deacutefilement de la barre de droite de haut en bas
MUTE Chaque canal peut ecirctre placeacute en mute Seacutelectionner le canal et pousser sur la manette ldquoPush Enterrdquo [2] pour valider le changement deacutetat Lindication du canal sera remplaceacutee par la lettre M et la barre sera totalement mise en eacutevidencePour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterations
c) BARRE DE NIVEAU DE SIGNALLindication du niveau de chaque canal est signaleacutee par le deacutefilement de la barre de gauche
d) MUTE GENERALIl est possible de mettre simultaneacutement toutes les entreacutees et les sorties en mute Tourner la manette ldquoFUNCTIONS SELECTORrdquo seacutelectionner la lettre M et pousser sur la manette Push EnterPour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterationsLe mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) MODES DE COMMANDEIl affiche le mode dutilisation etou les dispositifs qui sont relieacutes agrave lAC26N
Local = utilisation autonome Aucune connexion agrave un dispositif exteacuterieur
NET = relieacute directement au reacuteseau deacutedieacute RDNet et agrave lordinateur
USB = relieacute directement agrave un ordinateur par cacircble USB
f) INDICATION DETAT DE PARAMETRAGECette indication permet de constater si un ou plusieurs paramegravetre(s) du programme chargeacute aont eacuteteacute modifieacute(s) par rapport au dernier sauvetage
= programme dorigine
= programme avec des paramegravetres modifieacutes
g) PROGRAMME CONFIGURELe chiffre indique le programme chargeacute et utiliseacute par le systegraveme agrave lemplacement de sauvetage Consulter le menu de Preset pour de plus amples deacutetails
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
DESCRIPTION DE LA FENETRE MENU Ch Job
Cette fenecirctre permet dafficher la configuration de chaque canal
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) NIVEAU DU SIGNALIndique le gain du signal Laugmentation de lintensiteacute dun signal est libelleacutee en deacutecibel (dB) Le paramegravetre peut ecirctre seacutelectionneacute de -8000dB agrave +2000dB avec des pas de 001dB Une augmentation de 6dB est eacutegale approximativement au redoublement agrave leacutechelle lineacuteaire du niveau du signal sous tensionAvec un gain supeacuterieur agrave 0dB le signal est amplifieacute tandis quavec un gain infeacuterieur agrave 0dB le signal est atteacutenueacute
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
49
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
50
c) DELAI DU SIGNAL (DELAY)Le signal audio reproduit peut ecirctre retardeacute pour permettre lalignement acoustique Cela compense les diffeacuterentes positions des diffuseurs pendant linstallation et la reproduction sonore Il se libelle en mS Le paramegravetre peut ecirctre seacutelectionneacute de 00mS agrave 729mS avec un pas de 01mSPour aligner un signal audio il est possible dutiliser la formule suivante
Deacutelai = (GAPx1000)344
Deacutelai = ms (en millisecondes)GAP = distance du diffuseur du point de reacutefeacuterence (en megravetres)Vitesse du son = 344ms
d) MUTEChaque canal peut ecirctre placeacute en mute La mecircme commande peut ecirctre activeacutee dans la fenecirctre du menu meters NB Le mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) PhasePermet la rotation de phase de 180deg par rapport au signal entrantCette rotation permet loptimisation surtout des basses freacutequences dans les installations complexes
f) EGALISATIONCette commande ouvre la fenecirctre du menu deacutegalisation de chaque canal Elle sert surtout pour corriger une ou plusieurs freacutequences qui doivent ecirctre atteacutenueacutees ou augmenteacutees
M M
LAC26N gegravere 12 filtres par canal dentreacutee et sortie avec trois types de configurations diffeacuterentes - Leacutegaliseur PEQ (peaking equalizer) est ideacuteal pour identifier isoler et
corriger une seule plage de freacutequences bien deacutetermineacutee Toutes les freacutequences passent mais il augmente ou diminue uniquement celles autour de la freacutequence centrale pour une bande preacutecise et un gain deacutefini
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessus de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessous de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
f Numeacuterotation des 12 filtres disponibles pour cette entreacutee ou cette sortie1
f Le type de filtre est afficheacute 2
Dis Deacutesactiveacute (absent)
PEQ Peaking equlizer
Sh H Filtre high-shelf
Sh L Filtre high-shelf
Exemples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
REMARQUELe paramegravetre Bw deacutetermine le champ de freacutequences adjacent agrave la freacutequence configureacutee ougrave est activeacute le filtre Plus la valeur Bw est eacuteleveacutee plus vaste est le champ de freacutequences (1Bw=1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONCette commande ouvre la fenecirctre du menu de compression de chaque canal
g1) TresholdIdentifie le seuil ougrave commence le rapport de compression La valeur de base 11
g2) RatioIndique le rapport de conversion entre le signal entrant et le signal sortant
g3) Post Gain Attach Release HoldCes donneacutees deacutependent du rapport de conversion que lon veut obtenir - Post Gain est le gain de sortie- Attack est le temps dattaque - Release est le temps de relacircchement- Hold est le temps de maintien
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
52
DESCRIPTION DE LA FENETRE MENU Preset
Cette fenecirctre permet de meacutemoriser jusquagrave 32 configurations dans lAC26NLe fabricant fournit le systegraveme avec un programme configureacute et enregistreacute en position 0 et non susceptible deacutecrasement
032 Elle indique lemplacement de sauvetage de la configurationCe numeacutero apparaicirct dans la fenecirctre Meters en position (g) A tout moment le programme utiliseacute peut ecirctre afficheacute par lutilisateur
Empty Preset Cest le nom qui est associeacute au numeacutero de lemplacement quand aucune configuration (vide) nest enregistreacutee
Local preset Local preset est le nom qui est associeacute au numeacutero de lemplacement quand on enregistre une configuration NB = Il est possible denregistrer une configuration avec lenom souhaiteacute de 16 lettres tout au plus agrave condition que lonutilise linterface via lordinateur
Le nom du programme assigneacute est indiqueacutePour toucher agrave lapplication 3 choix soffrent agrave vous
Save Le programme est enregistreacute en meacutemoire de lAC26N
Del Le programme est effaceacute
Load Le programme est chargeacute et precirct agrave lemploi
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
51
DESCRIPTION DE LA FENETRE MENU X-Over
Cette fenecirctre permet de seacutelectionner un filtre passe bas un filtre passe haut ou par la combinaison des deux de creacuteer un filtre passe bande pour chaque sortieLe filtre actif est un Linkwitz-Riley qui permet de seacutelectionner la pente de 12dBoct 24dBoct ou 48dBoct et sa freacutequence de coupure
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) CANAUX DE SORTIE
Les connecteurs de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) FILTRE CROSSOVERSeacutelectionner le filtre selon les besoins Il est possible de seacutelectionner
Dis Aucun filtre activeacute
HP Filtre passe-haut laisse passer uniquement la partie de signal audio supeacuterieure agrave la freacutequence de coupure
LP Filtre passe-bas laisse passer uniquement la partie de signal audio infeacuterieure agrave la freacutequence de coupure
Configuration du filtre Passe-haut Passe-bas
Rien Dis Dis
Passe-haut HP Dis
Passe-bas Dis LP
Passe-bande HP LP
12dBoct
24dBoct
Hz
dB
Ga
in 48dBoct
12dBoct
24dBoct
Hz
dB
Ga
in
48dBoct
c) PENTE DATTENUATIONSeacutelectionner la pente datteacutenuation du signal audio en fonction de la diminution que lon veut obtenir Plus la pente datteacutenuation est eacuteleveacutee agrave eacutegaliteacute de freacutequence de coupure plus eacuteleveacutee sera la seacutelection du signal Il est possible de seacutelectionner
12 correspond agrave 12dboct
24 correspond agrave 24dboct
48 correspond agrave 48dboct
d) FREQUENCE DE COUPUREElle permet de reacutegler la freacutequence de passage des freacutequences infeacuterieures (filtre passe-bas) ou des freacutequences supeacuterieures (filtre passe-haut) uniquementLe choix de la coupure deacutepend de la reproduction que lon veut obtenirLuniteacute de mesure utiliseacutee est lHz
Hz
Hz
dB
dB
Ga
in
f0
f0
0dB0dB
0dB
-6dB
freacutequence
freacutequence
freacutequence
freacutequence
Ga
in
f0
0dB
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
53
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
54
DESCRIPTION DE LA FENETRE MENU Matrix
Elle permet de seacutelectionner le signal entrant agrave utiliser comme source pour chaque sortie
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) CANAUX DE SORTIEIdentification du canal sortant agrave reacutegler
b) IDENTIFICATIONS DES ENTREESSeacutelectionner le type de signal agrave associer agrave chaque sortie en fonction des besoins Il est possible de seacutelectionner
In A Le signal entrant A est associeacute
In B Le signal entrant B est associeacute
In A+B La somme algeacutebrique des deux signaux entrants A et B est associeacutee
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
DESCRIPTION DE LA FENETRE MENU Option
Permet dafficher les reacuteglages du systegraveme comme lassignation des entreacutees et des sorties latteacutenuation le contraste de laffichage et la version du logiciel
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcCette option permet de reacutegler le type de signal audio entrant
An In =signaux audio analogiques (entreacutees ldquoArdquo et ldquoBrdquo)
Dig In =signaux audio numeacuteriques (entreacutee AESEBU)
DigOut SrcCette option permet de seacutelectionner la source audio qui sera adresseacutee sur le connecteur AESEBU OUT (sortie numeacuterique)
An In = signaux audio des entreacutees analogiques
Dig In =signaux audio sur lentreacutee numeacuterique
OUT 1-2 = signaux audio sur les sorties 1 et 2
OUT 3-4 = signaux audio sur les sorties 3 et 4
OUT 5-6 = signaux audio sur les sorties 5 et 6
Input ModePermet de configurer les entreacutees
Indip = sont indeacutependantes et autonomes Ne sont soumises agrave aucun type de lien
Linked = sont unies et fonctionnent en mode steacutereacuteo Les compresseurs les filtres les deacutelais le volume sont identiques pour les deux canaux
Atten PadIndique le mode de reacuteglage du seacutelecteur ldquo-6dBrdquo placeacute agrave larriegravere [reacutef 5] Il faut activer ce seacutelecteur quand les niveaux dentreacutee analogiques sont trop eacuteleveacutes Le seacutelecteur sactive uniquement par le bouton Dans le menu il sagit dune simple visualisation
0dB = seacutelecteur non activeacute Les signaux dentreacutee sont identiques agrave la source entrante
-6dB = seacutelecteur activeacute Les signaux entrants sont atteacutenueacutes de -6dB par le processeur interne
ContrastIl permet de reacutegler le contraste de laffichage agrave cristaux liquides pour compenser la diffeacuterence de luminositeacute avec le lieu dinstallation Une plus grande clarteacute de laffichage permet de naviguer convenablement et rapidement dans les menusLe reacuteglage agrave la sortie de lusine du fabricant est de 60
10 plus clair 60 plus fonceacute 100
Fw VersIndique la version du logiciel du processeur
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
55
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
56
DONNES TECHINIQUES
PERFORMANCES AUDIOReacuteponse en freacutequence +- 01dB (20 to 30kHz)Plage dynamique 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsion 0002 (1kHz +4dBu)
PERFORMANCES AUDIO NUMERIQUES Processeur DSP 2856-bit Freacutequence de traitement des donneacutees 48KHzConvertisseurs analogiques 24-bit BURR BROWNDeacutelai de propagation 15msMeacutemorisations des configurations 32 preset
CONTROLES Affichage LCD graficoBoutonsCommandes ESC - MENU - FUNCTIONS SELECTION
ENTERENTREESSORTIESEntreacutee analogique ndeg2 x XLR (3 broches femelle)
Impeacutedance dentreacutee gt10KOhmNiveau maximum +21dBu senza PAD
+27dBu con PADSortie analogique ndeg6 x XLR (3 broches macircle )
Impeacutedance de sortie 50OhmNiveau maximum +21dBuType Balanceacute
Entreacutee numeacuterique ndeg1x XLR (3 broches femelle)Type SPDIF-AESEBU (AES3)
Sortie numeacuterique ndeg1x XLR (3 broches macircle )Type conforme agrave la norme de lentreacutee
EntreacuteesSortie Rdnet ndeg2 x XLR RJ45 (cacircble CAT 5)USB Type B
PARAMETRES DE CONTROLE DU SONGain -80dB a +20dB eacutetape 01dBDeacutelai Entreacutee 0 a 729mS eacutetape 01 mS
Sortie 0 a 340mS eacutetape 01mSRotation de phase 0deg - 180deg
COMPRESSIONSeuil -80dB a +20dB eacutetape 01dBRapport 11 a Inf1 eacutetape 001Gain agrave la sortie 0dB a 40dB eacutetape 01dBTemps dattaque 1mS a 1000mS eacutetape 01mSTemps de relacircchement 1mS a 1000mS eacutetape 01mSTemps de maintien 1mS a 1000mS eacutetape 01mS
EGALISEURS12 eacutegaliseurs pour chaque entreacutee et sortieType PEQ (parameacutetrique) Hi-shelf Lo-sheft
Freacutequence 20Hz a 20KHz eacutetape 1HzGain -30dB a +15dB eacutetape 001dBBande 005dB a 2dB eacutetape 001dB (uniquement pour PEQ)
FILTRES CROSSOVERFiltre Linkwitz Riley
Type HF high-shelfLF low-shelf
Pente 12dBoct - 24dBoct - 48dBoctFreacutequence de coupure 5Hz a 20KHz eacutetape 1Hz
ALIMENTATION Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)POIDS 19Kg
Remarques Speacutecifications sujettes agrave modifications sans preacuteavis
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
2 VIE ATTIVO2 WAY ACTIVE
3 VIE PASSIVO3 WAY PASSIVE
L
L
A
A
HIGH L
MID L
LOW HIGHMID RHIGHMID L
LOW L
HIGH R
MID R
LOW R
R
R
B
B
1
1
2
2
3
3
456
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
Menu Matrix configurationMatrix
57 58
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
EROUIG ATRIX TNM
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
OU
TP
UT
1
OU
TP
UT
2
OU
TP
UT
3
OU
TP
UT
4
OU
TP
UT
5
OU
TP
UT
6
AE
S-E
BU
OU
TP
UT
INP
UT
A
AE
S-E
BU
INP
UT
INP
UT
B
D D D D D D
D D
A A A A A A
A SA
MP
LE
RA
TE
CO
NV
A
LIN
KA
BL
E
SC
HE
MA
A B
LO
CC
HI -
BL
OC
K D
IAG
RA
MB
LO
CK
SC
HA
LT
BIL
D -
SC
HE
MA
S F
ON
CT
ION
NE
LS
LINE ARRAY SUB MONO ATTIVO
LINE ARRAY SUB MONO ACTIVEINGRESSI - INPUT
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
L
L
L
A
A
A
AESEBU IN
AESEBU IN
AESEBU IN
AESEBU OUT
AESEBU IN
AESEBU IN
AESEBU OUT
R
R
R
LR
B
B
B
123456
HIGHMID L
HIGHMID L HIGHMID R
HIGHMID R
LOW L LOW R
LAYER
DISPLAY MEMORY
FADER MODE
LAYER
DISPLAY MEMORY
FADER MODE
Ingresso ANALOGICO
ANALOG Input
Collegamento in cascata
Link connections
Ingresso DIGITALE
DIGITAL inputA B
BALANCED AUDIO INPUTS
-6dB
PUSH PUSH
IN OUT
AES EBUPUSH
Oppure
or
Oppure
or
Menu Option configurationOption
Menu Option configurationOption Menu Option configurationOption
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type Analog
AES out An In
Input type Analog
AES out An In
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
59 60
InA-B Src Dig InInA-B Src Dig InInA-B Src An InInA-B Src An In
frequenzaHz
dB
Gu
ad
ag
no
60 200 2800
0dB0dB
-6dB
Esempio di un sistema a 3-vie
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
Out 1 Out 2 Out 3
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Esempio di un sistema a 3-vie
61 62
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
26NAC 26NAC
R TE
DO
R
MO LEU O R CE S
E O TR L A
S O
O C ND I P
P hsuernE t
o su cti nF nel rS e tc o
E CSME UN
IGCHTE OL SN EOBd
ocaL l
M
0
484
467
430
44
31
75
12
7
DIMENSIONI DIMENSIONSABMESSUNGEN DIMENSIONS
AC26N verwaltet 12 Filter fuumlr jeden einzelnen Ein- und Ausgangskanal mit drei verschiedenen Konfigurationen- Equalizer PEQ (peaking equalizer) ist ideal um nur ein bestimmtes Frequenzband
zu identifizieren zu isolieren und zu korrigieren Es gehen alle Frequenzen durch aber nur die um die mittlere Frequenz steigt und sinkt um eine bestimmte Bandbreite und eine bestimmte Staumlrke
- Equalizer High-Shelf geht alle Frequenzen durch aber die Frequenzen uumlber der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
- Equalizer Low-Shelf geht alle Frequenzen durch aber die Frequenzen unter der gewaumlhlten Schnittfrequenz die fuumlr die indikative Staumlrke ausgewaumlhlt wurde steigt oder wird gedaumlmpft
f Nummerierung der 12 verfuumlgbaren Filter fuumlr diesen Ein- oder Ausgang1
f2 Es wird der Filtertyp angezeigt
Dis Ausgeschaltet (nicht vorhanden)
PEQ Peaking equalizer
Sh H Filter High-Shelf
Sh L Filter Low-shelf
Beispiele PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
ANMERKUNGDer Parameter Bw legt das Frequenzfeld neben der eingestellten Frequenz fest wo der Filter aktiviert wird je houmlher der Bw-Wert desto houmlher das Frequenzfeld (1Bw=1 Oktave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filter High-Shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filter Low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) KOMPRESSIONDieser Befehl oumlffnet das Menuumlfenster fuumlr die Kompression des einzelnen Kanals
g1) TresholdIdentifiziert die Schwelle an der das Kompressionsverhaumlltnis beginnt Der Basiswert 11
g2) RatioIdentifiziert das Kompressionsverhaumlltnis zwischen dem Ein- und Ausgangssignal
g3) Post Gain Attach Release HoldDiese Daten entsprechen dem Kompressionsverhaumlltnis das man erreichen moumlchte
Post Gain ist der Gewinn am AusgangAttack ist die Anschlusszeit Release ist die ReleasezeitHold ist die Beibehaltungszeit
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
BESCHREIBUNG DES MENUumlFENSTERS Preset
Dieses Fenster erlaubt bis zu 32 Konfigurationen im AC26N zu speichernDer Hersteller liefert das System mit einem voreingestellten Programm das auf Position 0 gespeichert ist und nicht uumlberschrieben werden kann
032 Es zeigt die Lokalisierung der Speicherung der KonfigurationDiese Nummer erscheint auch im Fenster Meters auf der Position (g) Das benutzte Programm kann jederzeit vom Benutzer angezeigt werden
Empty Preset Es ist der Name der der Nummer der Lokalisierung zugeordnet wird wenn keine Einstellung gespeichert ist (leer)
Local preset Es i s t de r Name de r de r Nummer de r Loka l i s i e rung zugeordnet wird wenn eine Konfiguration gespeichert wird
ANMERKUNG = Man kann eine Einstellung mit dem gewuumlnschten Namen mit max 16 Buchstaben nur speichern wenn man die Schnittstelle uumlber den Computer benutzt
Bei der Wahl eines Programms erscheint folgendes Fenster
Anzeige des Namens der dem Programm zugeordnet istUm auf die Anwendung einzuwirken stehen 3 Auswahlmoumlglichkeiten zur Verfuumlgung
Das Programm wird im Speicher des AC 26N gespeichert
Das Programm wird geloumlscht
Das Programm wird geladen und ist bereit fuumlr die Benutzung
Save
Del
Load
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
37
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
38
BESCHREIBUNG DES MENUumlFENSTERS X-Over
Dieses Fenster erlaubt fuumlr jeden Ausgang einen Bassdurchgangsfilter einen Hochdurchgangsfilter oder mittels Kombination von beiden einen Banduumlbergangsfilter zu waumlhlenDer Filter ist ein Linkwitz-Riley wo man die Neigung von 12 dBoct 24dBoct oder 48 dBoct und die entsprechende Schnittfrequenz auswaumlhlen kann
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) AUSGANGSKANAumlLE
Die Steckverbinder am Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) FILTER CROSSOVERDen Filter nach Bedarf waumlhlen Man kann folgendes auswaumlhlen
Dis Kein Filter aktiviert
HP Hochdurchgangsfilter nur den Teil des Audiosignals durchlassen der uumlber der Schnittfrequenz liegt
LP Bassdurchgangsfilter nur den Teil des Audiosignals durchlassen der unter der Schnittfrequenz liegt
Filter-Konfiguration Tiefpass Hochpass
Nichts Dis Dis
Hochpass HP Dis
Tiefpass Dis LP
Bandpass HP LP
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
c) DAumlMPFUNGSNEIGUNGDie Daumlmpfungsneigung des Audiosignals auf der Basis der Verringerung auswaumlhlen die man erreichen moumlchte Je houmlher die Daumlmpfungsneigung bei gleicher Schnittfrequenz desto groumlszliger ist die Signalauswahl Man kann folgendes waumlhlen
12 entsprechend 12 dboct
24 entsprechend 24 dboct
48 entsprechend 48 dboct
d) SCHNITTFREQUENZErlaubt die Durchgangsfrequenz der niederen Frequenzen (Bassdurchgangsfilter) oder der hohen Frequenzen (Hochdruchgangsfilter) einzustellenDie Auswahl des Schnitts bezieht sich auf die Wiedergabe die man erreichen moumlchteDie benutzte Maszligeinheit ist Hz
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
BESCHREIBUNG DES MENUumlFENSTERS Matrix
Erlaubt fuumlr jeden Ausgang das Eingangssignal zu waumlhlen das als Quelle benutzt werden soll
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) AUSGANGSKANAumlLEIdentifizierung des einzustellenden Ausgangskanals
b) IDENTIFIZIERUNG DER EINGAumlNGEDen Signaltyp auswaumlhlen der nach eigener Anforderung jedem einzelnen Ausgang zugeordnet werden soll Man kann folgendes waumlhlen
In A Das Signal wird dem Eingang A zugeordnet
In B Das Signal wird dem Eingang B zugeordnet
In A+B Zuordnung der a lgebra ischen Summe der be iden Eingangssignale A und B
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
BESCHREIBUNG DES MENUumlFENSTERS Option
Erlaubt die Anzeige der Systemeinstellungen wie die Zuordnung der Ein- und Ausgaumlnge Daumlmpfung Displaykontrast und Firmware-Version
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B Src
Diese Option erlaubt die Einstellung des Audio-Signaltyps am Eingang
Analoge Audiosignale (Eingaumlnge A und B)
Digitale Audiosignale (Eingang AESEBU)
DigOut Src
An In =Audiosignale an den analogen Eingaumlngen
Dig In =Audiosignale am digitalen Eingang
OUT 1-2 =Audiosignale an den Ausgaumlngen 1 und 2
OUT 3-4 =Audiosignale an den Ausgaumlngen 3 und 4
OUT 5-6 =Audiosignale an den Ausgaumlngen 5 und 6
Input Mode
An In
Dig In
Indip =
Linked =
Diese Option erlaubt die Audioquelle zu waumlhlen die fuumlr den Steckverbinder AESEBU OUT (digitaler Ausgang) bestimmt ist
Erlaubt die Eingaumlnge zu konfigurieren
Sie sind unabhaumlngig und selbststaumlndig sie unterliegen keinen Verpflichtungen untereinander Sie sind verbunden und funktionieren im Stereo-Modus
Die Kompressoren Filter Verzoumlgerungen die Lautstaumlrke sind bei beiden Kanaumllen identisch
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
39
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
40
Atten PadZeigt an wie der Wahlschalter -6 dB auf der Ruumlckseite eingestellt ist [Ref 5] Dieser Wahlschalter muss aktiviert werden wenn das Level an den analogen Eingaumlngen zu hoch ist Der Wahlschalter wird uumlber die Taste aktiviert im Menuuml gibt es nur eine Anzeige
0dB = Wahlschalter nicht aktiviert
-6dB = Wahlschalter aktiviert
Contrast
10 heller 60 dunkler 100
Fw Vers
Die Eingangssignale sind dieselben wie die Eingangsquelle
Die Eingangssignale werden vom internen Prozessor um -6 dB gedaumlmpft
Erlaubt den Kontrast des LCD-Displays einzustellen um den Unterschied der Helligkeit auf den Installationsort auszurichten Ein deutlicheres Display erlaubt auf korrekte und schnelle Weise innerhalb der Menuumls zu surfenDie Hersteller-Einstellung am Ausgang liegt bei 60
Zeigt die Firmware-Version des Prozessors an
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
41
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
42
TECHNISCHE DATEN
Antwort in FrequenzDynamische GammaCMMRCrosstalkDistorsion
ProzessorFrequenz der DatenausarbeitungAnaloge Converter Verzoumlgerung der VerteilungSpeicherung der Konfigurationen
DisplayTastenBedienungen
Analoger Eingang ndeg2 x XLR (3-poliger Female Stecker)Impedanz des Eingangs gt10KOhmMaximales Level +21dBu ohne PAD
+27dBu bei PAD
Impedanz des Ausgangs 50OhmMaximales Level +21dBu Typ symmetrisch
Typ SPDIF-AESEBU (AES3)
Typ Entsprechend dem Standard des Eingang
Typ
Typ
NETZSPANNUNGABMESSUNGEN (BXHXT)GEWICHT
AUDIO-LEISTUNGEN+- 01dB (20 to 30kHz)116dB typgt 60dB (50 to 10kHz)lt -100dB0002 (1kHz +4dBu)
DIGITALE AUDIO-LEISTUNGEN DSP 2856-bit 48KHz24-bit BURR BROWN15ms32 preset
KONTROLLEN LCD GrafikESC - MENU - FUNCTIONS SELECTIONENTER
EIN-AUSGAumlNGE
Analoger Ausgang ndeg6 x XLR (3-poliger Male Stecker)
Digitaler Eingang ndeg1x XLR (3-poliger female Stecker)
Digitaler Ausgang ndeg1x XLR (3-poliger Male Stecker)
Ein-Ausgang Rdnet ndeg2 x XLR RJ45 (kabel CAT 5) USB Typ B
KONTROLLPARAMETER AUDIOStaumlrke -80dB a +20dB step 01dBVerzoumlgerung Eingang 0 a 729mS step 01 mS
Ausgang 0 a 340mS step 01mSPhasenrotation 0deg - 180deg
KOMPRESSIONSchwelle -80dB a +20dB step 01dBVerhaumlltnis 11 a Inf1 step 001Staumlrke am Ausgang 0dB a 40dB step 01dBAnschlusszeit 1mS a 1000mS step 01mSReleasezeit 1mS a 1000mS step 01mSBeibehaltungszeit 1mS a 1000mS step 01mS
EQUALIZER12 Equalizer fuumlr jeden Ein- und Ausgang
PEQ (parametrischer) Hi-shelf Lo-sheftFrequenz 20Hz a 20KHz step 1HzStaumlrke -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (lediglich PEQ)
FILTER CROSSOVERFilter Linkwitz Riley
HP HochdurchgangsfilterLP Bassdurchgangsfilter
Neigung 12dBoct - 24dBoct - 48dBoctSchnittfrequenz 5Hz a 20KHz step 1Hz
Full-range 100-240Vac 50-60Hz430482x43x130mm 19Kg
AnmerkungenSpezifikationen unterliegen Aumlnderungen ohne Vorankuumlndigung
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
INTRODUCTIONAC26N est un processeur audio numeacuterique pour la gestion de leacutequipement audio conccedilu pour des installations fixes et mobiles Il fonctionne selon une technologie de pointe avec des processeurs agrave 2856bits et des convertisseurs ADDA agrave 24-bits hautes performances Les fonctions du processeur sont les niveaux dentreacutee et de sortie le deacutelai (delay) la polariteacute 12 bandes deacutegalisation par canal dentreacutee et de sortie diffeacuterentes seacutelections de croisement (crossover) et un limiteur hautes performances Le controcircle des filtres a une reacutesolution de 1Hz Les entreacutees et les sorties peuvent ecirctre programmeacutees en plusieurs configurations pour satisfaire tous les besoins AC26N peut ecirctre controcircleacute en temps reacuteel et tous les paramegravetres peuvent ecirctre configureacutes depuis le pupitre frontale et par ordinateur avec interface graphique intuitive accessible via le logiciel laquoDVA Networkraquo et une connexion de reacuteseau deacutedieacutee RDnet ou USBLa mise agrave jour du logiciel pour lUniteacute centrale et DSP par ordinateur portable permet de maintenir le dispositif actualiseacute Il est possible denregistrer et de rappeler 32 configurations preacute-eacutequipeacutees de configuration
Contenu de lemballage - AC26N - Mode demploi- CD logiciel- Cacircble dalimentation
Caracteacuteristiques- 2 entreacutees et 6 sorties avec adressage flexible- Entreacutee et sortie steacutereacuteo AESEBU adressables - DSP 2856-bit- Convertisseurs AD BURR BWOWN 24-bit hautes performances- Freacutequence de reacutesolution des filtres 1 Hz - 12 eacutegaliseurs parameacutetriques pour chaque entreacutee et sortie- 2 filtres de croisement par sortie avec pente seacutelectionnable agrave 122448dBoct- DRC agrave configuration multiple hautes performances pour configuration limiteur
compression pour chaque entreacutee et sortie- Niveau reacuteglable en dB polariteacute et deacutelai pour chaque entreacutee et sortie- Mise agrave jour du micrologiciel par lordinateur- Affichage graphique agrave cristaux liquides- 32 preacutereacuteglages enregistrables par lutilisateur- Interface USB pour le controcircle et la configuration par ordinateur- Interface RDnet permettant de controcircler jusquagrave 256 dispositifs agrave distance
PC
PC
RDNETcontrol(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FONCTIONS DE LA FACE AVANT
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
COMMANDES ET FONCTIONS1) AFFICHAGE
Laffichage graphique agrave cristaux liquides permet de visualiser et deacutediter les informations de lAC26N sans utiliser lordinateur Le contraste peut ecirctre configureacute dans le menu principal
2) MANETTE Functions Selector et Push EnterCe controcircle permet de se deacuteplacer de seacutelectionner et de modifier les paramegravetres dans les menus affichables agrave leacutecranRotation de la manette (Functions Selectors)- permet de se deacuteplacer sur les diffeacuterentes pages du menu - permet de modifier les paramegravetres seacutelectionneacutesPression de la manette (Push Enter)- permet de seacutelectionnervalider les paramegravetres
3) Bouton ESC Ce controcircle permet de quitter les menus afficheacutes ou de revenir agrave la visualisation preacuteceacutedente
4) Bouton Menu Ce controcircle permet dacceacuteder directement au menu principal
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
Fra
nccedilais
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
43
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
Fra
nccedilais
44
DVA Network
AC26N est eacutequipeacute dune interface de reacuteseau proprieacutetaire deacutenommeacutee RDNET au moyen de laquelle il est possible de sinterfacer agrave lordinateur agrave travers un peacuteripheacuterique (RDNET control)
Pour cela un protocole de communication a eacuteteacute deacuteveloppeacute avec lequel il est possible de recevoir et denvoyer les donneacutees ce branchement permet de faire le monitorage en temps reacuteel des paramegravetres du diffuseur comme puissance de sortie tempeacuterature de lamplificateur eacutetat du limiteur etc Il est aussi possible de seacutelectionner diffeacuterentes eacutegalisations ou den creacuteer de nouvelles et de reacutegler les niveaux de volume souhaiteacutes au moyen dun plug-in approprieacute
On conseille de teacuteleacutecharger gratuitement le logiciel DVA Network directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
DVA USB Manager
On conseille de teacuteleacutecharger gratuitement le logiciel DVA USB Manager directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
Le micrologiciel du module amplificateur peut ecirctre remis agrave jour par le port USBPour rendre cette mise agrave jour possible et facile un programme speacutecifique a eacuteteacute deacuteveloppeacute
DOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
CONNEXIONS DU PANNEAU ARRIEgraveRE
1586 75 141210 11 13 169 17
14) Connecteur ldquo USBrdquoCe connecteur USB (type B) permet de connecter le processeur agrave un ordinateur pour le controcircle et la mise agrave jour du micrologiciel via un programme deacutedieacute (DVA Network)
15) PRISE DALIMENTATION MAINSPermet la connexion du cacircble dalimentation fourni de seacuterie
16) PORTE-FUSIBLE FUSELogement pour fusible de ligne
17) INTERRUPTEUR GENERAL POWERLinterrupteur permet de mettre en marche ou deacuteteindre le controcircleur audio
COMMANDES ET FONCTIONS
5) SELECTEUR ldquo-6dBrdquoLe seacutelecteur permet de reacuteduire de 6dB les niveaux dentreacutee analogiques XLR [6] tout en compensant les niveaux eacuteleveacutes de sortie des meacutelangeurs ou dautres dispositifs audio Quand la barre du niveau de signal des entreacutees sur laffichage [1] reste au maximum cela indique que le niveau du signal entrant est eacuteleveacute Il est alors conseilleacute dutiliser latteacutenuation -6dBIl est possible de veacuterifier quand le seacutelecteur est activeacute par le menu Option
6) CONNECTEURS DENTREE ldquoArdquo ET ldquoBrdquoEntreacutees eacutequilibreacutees au niveau de la ligneIls sont en mesure daccepter des connecteurs XLR macircles
7) CONNECTEURS DE SORTIE ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo ET ldquo6rdquoSorties eacutequilibreacutees au niveau de la ligne Ils sont en mesure daccepter des connecteurs XLR femelles
Prendre garde agrave brancher convenablement les sorties sur les diffuseurs ou les amplificateurs en fonction des configurations de chaque canal pour eacuteviter des deacutegacircts et des problegravemes de fonctionnement
Section ldquoAESEBUrdquo
8) CONNECTEUR DENTREE INOutre les entreacutees audio analogiques une entreacutee audio numeacuterique SPDIF-AESEBU (AES3) a eacuteteacute preacutevue et peut ecirctre seacutelectionneacutee par le menu de setupLentreacutee requiert une connexion eacutequilibreacutee en utilisant un connecteur XLR avec un cacircble agrave 3 conducteurs de 110ohm torsadeacute
9) CONNECTEUR DE SORTIE OUTCe connecteur permet de relancer le signal audio dans les entreacutees analogiques ou numeacuteriques ou sur les sorties La source doit ecirctre reacutegleacutee par le menu OptionLa connexion sera conforme agrave la mecircme norme que lentreacutee [reacutef8]
Section ldquoRDNETrdquo
10) CONNECTEUR DENTREE DATA INPUTConnecteur RJ45 entreacutee de donneacutees
11) CONNECTEUR DE SORTIE DATA LINKConnecteur RJ45 sortie de donneacutees pour la connexion de seacuterie en cascade
12) VOYANT LUMINEUX ONCe voyant de couleur verte sallume uniquement quand lAC26N a reconnu et est connecteacute agrave luniteacute principale RDNET par lordinateur
13) VOYANT LUMINEUX ACTIVECe voyant de couleur jaune clignote quand une transmission des donneacutees est active entre RDNET et le dispositif
PUSH
P SHU
SHPU
P SHU
PUSH
CONNEXIONS
Audio analogiquesLes connexions eacutequilibreacutees permettent de reacuteduire au minimum le bruit provoqueacute par les cacircbles et dutiliser de longs cacircblesCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLe connecteur XLR doit ecirctre brancheacute avec la broche 1 agrave la masse la broche 2 au chaud (+) et la broche 3 au froid (-) En cas de cacircble blindeacute brancher le blindage agrave la broche 1Les cacircbles de connexion XLR-XLR et XLR-Jack14(63mm) peuvent semployer pour la connexion agrave lAC26N
12
3
Entreacutee
Entreacutee
XLR - femme
XLR - femme
1 2
3
Sortie
Sortie
XLR - Macircle
XLR - Macircle
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2 = Point chaudPhase +VE
Broche 3 =Point froidPhase -VE
Broche 3 =Point froidPhase -VE
Anneau
Manchon
Pointe Point chaudPhase +VE
Anneau = Point froidPhase -VE
ManchonB Masselindeacute
Pointe
Les connexions deacuteseacutequilibreacutees peuvent semployer mecircme si le bruit provoqueacute par les cacircbles augmente Les cacircbles ne peuvent deacutepasser 5m de longCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLes connexions deacuteseacutequilibreacutees peuvent abaisser le niveau du signal entrant de 6dB Pour remeacutedier agrave cet inconveacutenient il faut brancher la broche 3 agrave la masse mecircme si cela augmente le bruit
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
45
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
46
12
3
1 2
3
Pointe Manchon
Pointe = Signal
Broche 3 = Link to Pin 1
Broche 3 = Link to Pin 1
ManchonB Masselindeacute
Audio numeacuteriques (AESEBU)
AESEBU (protocole AES3) est une entreacutee eacutequilibreacutee isoleacutee eacutelectriquement agrave laide dun transformateur Elle permet demployer deux canaux audio dans un seul cacircble bipolaire blindeacute Les caracteacuteristiques du cacircble doivent ecirctre de 3 pocircles impeacutedance 100ohm torsadeacute et blindeacute avec connecteur XLR (AES3 standard)
RJ 45
|1|2|3|4|5|6|7|8|
RDnet
Chaque port RDNet des Control 2 et Control 8 peut ecirctre brancheacute agrave un maximum de 32 dispositifs compatibles placeacutes en cascade Dans lexemple suivant le port de luniteacute de controcircle RDNET CONTROL 2 est relieacute agrave lentreacutee DATA INPUT dun AC26N dont la sortie parallegravele DATA LINK est envoyeacutee agrave lentreacutee de lAC26N successif Dans lexemple [n] est un nombre compris entre 3 et 32 (limite maximale des dispositifs que lon peut relier agrave un sous-reacuteseau)
La longueur totale du cacircble CAT5 dun sous-reacuteseau NE peut PAS deacutepasser 900 megravetres
Le connecteur doit ecirctre relieacute comme 1 ndash disponible pour dautres fonctions (par exemple audio +) 2 ndash disponible pour dautres fonctions (par exemple audio )3 ndash disponible pour dautres fonctions (par exemple masse analogique)4 ndash masse numeacuterique5 ndash masse numeacuterique6 ndash disponible pour dautres fonctions (par exemple alimentation)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
MISE EN MARCHE
Lors de la mise en marche du dispositif linitialisation deacutebute et dure quelques secondes Leacutecran affiche le modegravele le logo et la barre de progression du chargement du programme
En fin de processus dinstallation leacutecran affiche la fenecirctre du menu Meters Pour connaicirctre les indications en deacutetail consulter le paragraphe DESCRIPTION FENETRE MENU Meters
LAC26N est precirct agrave lemploi
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION ET VISUALISATION
Pour entrer dans la fenecirctre du menu principal il faut pousser sur la touche MENU ( ) agrave lavant du dispositifDune page quelconque du menu en poussant sur la touche ESCrdquo ( ) on revient automatiquement sur la page-eacutecran preacuteceacutedente
MENU PRINCIPAL
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Le processeur contient six menus Ils montrent etou configurent les paramegravetres du systegravemeLes menus principaux sont
Meters Visualisation des niveaux des entreacutees et des sorties visualisation du programme utiliseacute et eacutetat mute rapide
Preset Meacutemoriser enregistrer et eacuteliminer les configurations du systegraveme
Matrix seacutelectionner les sorties en fonction du signal entrant
Ch Job configuration de chaque signal
X-Over configurer les freacutequences de coupure et les types de filtres pour chaque sortie
Option attribution des entreacutees et des sorties contraste daffichage la version du micrologiciel les entreacutees et dautres options
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
47
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
48
DESCRIPTION DE LA FENETRE MENU Metersrdquo
Cette fenecirctre permet de visualiser les configurations et leacutetat geacuteneacuteral des entreacutees et des sorties la version du programme utiliseacute son eacutetat et le mode de pilotage du systegraveme
Les menus et les options afficheacutees peuvent se seacutelectionner en tournant la manette ldquoFUNCTIONS SETECTORrdquo ( ) Pour avoir accegraves agrave linteacuterieur de la seacutelection il faut mettre le paramegravetre souhaiteacute en eacutevidence et pousser sur la manette ldquoPush Enterrdquo ( | ) Il faut en faire de mecircme pour seacutelectionner etou modifier les options dans les commandes du menu
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositifAvec des signaux dentreacutee numeacuteriques les indications ldquoArdquo et ldquoBrdquo correspondent agrave lentreacuteeEn tournant la manette ldquoFUNCTIONS SELECTORrdquo [2] on fait deacutefiler en mode cyclique les canaux dentreacutee de sortie et lindication de mute geacuteneacuteral (d) le canal seacutelectionneacute est mis en eacutevidence
b) BARRE DE NIVEAU DE COMPRESSIONMUTE CANAL
COMPRESSION DE SIGNALLa compression du signal est visualiseacutee par le deacutefilement de la barre de droite de haut en bas
MUTE Chaque canal peut ecirctre placeacute en mute Seacutelectionner le canal et pousser sur la manette ldquoPush Enterrdquo [2] pour valider le changement deacutetat Lindication du canal sera remplaceacutee par la lettre M et la barre sera totalement mise en eacutevidencePour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterations
c) BARRE DE NIVEAU DE SIGNALLindication du niveau de chaque canal est signaleacutee par le deacutefilement de la barre de gauche
d) MUTE GENERALIl est possible de mettre simultaneacutement toutes les entreacutees et les sorties en mute Tourner la manette ldquoFUNCTIONS SELECTORrdquo seacutelectionner la lettre M et pousser sur la manette Push EnterPour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterationsLe mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) MODES DE COMMANDEIl affiche le mode dutilisation etou les dispositifs qui sont relieacutes agrave lAC26N
Local = utilisation autonome Aucune connexion agrave un dispositif exteacuterieur
NET = relieacute directement au reacuteseau deacutedieacute RDNet et agrave lordinateur
USB = relieacute directement agrave un ordinateur par cacircble USB
f) INDICATION DETAT DE PARAMETRAGECette indication permet de constater si un ou plusieurs paramegravetre(s) du programme chargeacute aont eacuteteacute modifieacute(s) par rapport au dernier sauvetage
= programme dorigine
= programme avec des paramegravetres modifieacutes
g) PROGRAMME CONFIGURELe chiffre indique le programme chargeacute et utiliseacute par le systegraveme agrave lemplacement de sauvetage Consulter le menu de Preset pour de plus amples deacutetails
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
DESCRIPTION DE LA FENETRE MENU Ch Job
Cette fenecirctre permet dafficher la configuration de chaque canal
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) NIVEAU DU SIGNALIndique le gain du signal Laugmentation de lintensiteacute dun signal est libelleacutee en deacutecibel (dB) Le paramegravetre peut ecirctre seacutelectionneacute de -8000dB agrave +2000dB avec des pas de 001dB Une augmentation de 6dB est eacutegale approximativement au redoublement agrave leacutechelle lineacuteaire du niveau du signal sous tensionAvec un gain supeacuterieur agrave 0dB le signal est amplifieacute tandis quavec un gain infeacuterieur agrave 0dB le signal est atteacutenueacute
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
49
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
50
c) DELAI DU SIGNAL (DELAY)Le signal audio reproduit peut ecirctre retardeacute pour permettre lalignement acoustique Cela compense les diffeacuterentes positions des diffuseurs pendant linstallation et la reproduction sonore Il se libelle en mS Le paramegravetre peut ecirctre seacutelectionneacute de 00mS agrave 729mS avec un pas de 01mSPour aligner un signal audio il est possible dutiliser la formule suivante
Deacutelai = (GAPx1000)344
Deacutelai = ms (en millisecondes)GAP = distance du diffuseur du point de reacutefeacuterence (en megravetres)Vitesse du son = 344ms
d) MUTEChaque canal peut ecirctre placeacute en mute La mecircme commande peut ecirctre activeacutee dans la fenecirctre du menu meters NB Le mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) PhasePermet la rotation de phase de 180deg par rapport au signal entrantCette rotation permet loptimisation surtout des basses freacutequences dans les installations complexes
f) EGALISATIONCette commande ouvre la fenecirctre du menu deacutegalisation de chaque canal Elle sert surtout pour corriger une ou plusieurs freacutequences qui doivent ecirctre atteacutenueacutees ou augmenteacutees
M M
LAC26N gegravere 12 filtres par canal dentreacutee et sortie avec trois types de configurations diffeacuterentes - Leacutegaliseur PEQ (peaking equalizer) est ideacuteal pour identifier isoler et
corriger une seule plage de freacutequences bien deacutetermineacutee Toutes les freacutequences passent mais il augmente ou diminue uniquement celles autour de la freacutequence centrale pour une bande preacutecise et un gain deacutefini
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessus de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessous de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
f Numeacuterotation des 12 filtres disponibles pour cette entreacutee ou cette sortie1
f Le type de filtre est afficheacute 2
Dis Deacutesactiveacute (absent)
PEQ Peaking equlizer
Sh H Filtre high-shelf
Sh L Filtre high-shelf
Exemples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
REMARQUELe paramegravetre Bw deacutetermine le champ de freacutequences adjacent agrave la freacutequence configureacutee ougrave est activeacute le filtre Plus la valeur Bw est eacuteleveacutee plus vaste est le champ de freacutequences (1Bw=1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONCette commande ouvre la fenecirctre du menu de compression de chaque canal
g1) TresholdIdentifie le seuil ougrave commence le rapport de compression La valeur de base 11
g2) RatioIndique le rapport de conversion entre le signal entrant et le signal sortant
g3) Post Gain Attach Release HoldCes donneacutees deacutependent du rapport de conversion que lon veut obtenir - Post Gain est le gain de sortie- Attack est le temps dattaque - Release est le temps de relacircchement- Hold est le temps de maintien
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
52
DESCRIPTION DE LA FENETRE MENU Preset
Cette fenecirctre permet de meacutemoriser jusquagrave 32 configurations dans lAC26NLe fabricant fournit le systegraveme avec un programme configureacute et enregistreacute en position 0 et non susceptible deacutecrasement
032 Elle indique lemplacement de sauvetage de la configurationCe numeacutero apparaicirct dans la fenecirctre Meters en position (g) A tout moment le programme utiliseacute peut ecirctre afficheacute par lutilisateur
Empty Preset Cest le nom qui est associeacute au numeacutero de lemplacement quand aucune configuration (vide) nest enregistreacutee
Local preset Local preset est le nom qui est associeacute au numeacutero de lemplacement quand on enregistre une configuration NB = Il est possible denregistrer une configuration avec lenom souhaiteacute de 16 lettres tout au plus agrave condition que lonutilise linterface via lordinateur
Le nom du programme assigneacute est indiqueacutePour toucher agrave lapplication 3 choix soffrent agrave vous
Save Le programme est enregistreacute en meacutemoire de lAC26N
Del Le programme est effaceacute
Load Le programme est chargeacute et precirct agrave lemploi
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
51
DESCRIPTION DE LA FENETRE MENU X-Over
Cette fenecirctre permet de seacutelectionner un filtre passe bas un filtre passe haut ou par la combinaison des deux de creacuteer un filtre passe bande pour chaque sortieLe filtre actif est un Linkwitz-Riley qui permet de seacutelectionner la pente de 12dBoct 24dBoct ou 48dBoct et sa freacutequence de coupure
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) CANAUX DE SORTIE
Les connecteurs de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) FILTRE CROSSOVERSeacutelectionner le filtre selon les besoins Il est possible de seacutelectionner
Dis Aucun filtre activeacute
HP Filtre passe-haut laisse passer uniquement la partie de signal audio supeacuterieure agrave la freacutequence de coupure
LP Filtre passe-bas laisse passer uniquement la partie de signal audio infeacuterieure agrave la freacutequence de coupure
Configuration du filtre Passe-haut Passe-bas
Rien Dis Dis
Passe-haut HP Dis
Passe-bas Dis LP
Passe-bande HP LP
12dBoct
24dBoct
Hz
dB
Ga
in 48dBoct
12dBoct
24dBoct
Hz
dB
Ga
in
48dBoct
c) PENTE DATTENUATIONSeacutelectionner la pente datteacutenuation du signal audio en fonction de la diminution que lon veut obtenir Plus la pente datteacutenuation est eacuteleveacutee agrave eacutegaliteacute de freacutequence de coupure plus eacuteleveacutee sera la seacutelection du signal Il est possible de seacutelectionner
12 correspond agrave 12dboct
24 correspond agrave 24dboct
48 correspond agrave 48dboct
d) FREQUENCE DE COUPUREElle permet de reacutegler la freacutequence de passage des freacutequences infeacuterieures (filtre passe-bas) ou des freacutequences supeacuterieures (filtre passe-haut) uniquementLe choix de la coupure deacutepend de la reproduction que lon veut obtenirLuniteacute de mesure utiliseacutee est lHz
Hz
Hz
dB
dB
Ga
in
f0
f0
0dB0dB
0dB
-6dB
freacutequence
freacutequence
freacutequence
freacutequence
Ga
in
f0
0dB
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
53
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
54
DESCRIPTION DE LA FENETRE MENU Matrix
Elle permet de seacutelectionner le signal entrant agrave utiliser comme source pour chaque sortie
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) CANAUX DE SORTIEIdentification du canal sortant agrave reacutegler
b) IDENTIFICATIONS DES ENTREESSeacutelectionner le type de signal agrave associer agrave chaque sortie en fonction des besoins Il est possible de seacutelectionner
In A Le signal entrant A est associeacute
In B Le signal entrant B est associeacute
In A+B La somme algeacutebrique des deux signaux entrants A et B est associeacutee
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
DESCRIPTION DE LA FENETRE MENU Option
Permet dafficher les reacuteglages du systegraveme comme lassignation des entreacutees et des sorties latteacutenuation le contraste de laffichage et la version du logiciel
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcCette option permet de reacutegler le type de signal audio entrant
An In =signaux audio analogiques (entreacutees ldquoArdquo et ldquoBrdquo)
Dig In =signaux audio numeacuteriques (entreacutee AESEBU)
DigOut SrcCette option permet de seacutelectionner la source audio qui sera adresseacutee sur le connecteur AESEBU OUT (sortie numeacuterique)
An In = signaux audio des entreacutees analogiques
Dig In =signaux audio sur lentreacutee numeacuterique
OUT 1-2 = signaux audio sur les sorties 1 et 2
OUT 3-4 = signaux audio sur les sorties 3 et 4
OUT 5-6 = signaux audio sur les sorties 5 et 6
Input ModePermet de configurer les entreacutees
Indip = sont indeacutependantes et autonomes Ne sont soumises agrave aucun type de lien
Linked = sont unies et fonctionnent en mode steacutereacuteo Les compresseurs les filtres les deacutelais le volume sont identiques pour les deux canaux
Atten PadIndique le mode de reacuteglage du seacutelecteur ldquo-6dBrdquo placeacute agrave larriegravere [reacutef 5] Il faut activer ce seacutelecteur quand les niveaux dentreacutee analogiques sont trop eacuteleveacutes Le seacutelecteur sactive uniquement par le bouton Dans le menu il sagit dune simple visualisation
0dB = seacutelecteur non activeacute Les signaux dentreacutee sont identiques agrave la source entrante
-6dB = seacutelecteur activeacute Les signaux entrants sont atteacutenueacutes de -6dB par le processeur interne
ContrastIl permet de reacutegler le contraste de laffichage agrave cristaux liquides pour compenser la diffeacuterence de luminositeacute avec le lieu dinstallation Une plus grande clarteacute de laffichage permet de naviguer convenablement et rapidement dans les menusLe reacuteglage agrave la sortie de lusine du fabricant est de 60
10 plus clair 60 plus fonceacute 100
Fw VersIndique la version du logiciel du processeur
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
55
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
56
DONNES TECHINIQUES
PERFORMANCES AUDIOReacuteponse en freacutequence +- 01dB (20 to 30kHz)Plage dynamique 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsion 0002 (1kHz +4dBu)
PERFORMANCES AUDIO NUMERIQUES Processeur DSP 2856-bit Freacutequence de traitement des donneacutees 48KHzConvertisseurs analogiques 24-bit BURR BROWNDeacutelai de propagation 15msMeacutemorisations des configurations 32 preset
CONTROLES Affichage LCD graficoBoutonsCommandes ESC - MENU - FUNCTIONS SELECTION
ENTERENTREESSORTIESEntreacutee analogique ndeg2 x XLR (3 broches femelle)
Impeacutedance dentreacutee gt10KOhmNiveau maximum +21dBu senza PAD
+27dBu con PADSortie analogique ndeg6 x XLR (3 broches macircle )
Impeacutedance de sortie 50OhmNiveau maximum +21dBuType Balanceacute
Entreacutee numeacuterique ndeg1x XLR (3 broches femelle)Type SPDIF-AESEBU (AES3)
Sortie numeacuterique ndeg1x XLR (3 broches macircle )Type conforme agrave la norme de lentreacutee
EntreacuteesSortie Rdnet ndeg2 x XLR RJ45 (cacircble CAT 5)USB Type B
PARAMETRES DE CONTROLE DU SONGain -80dB a +20dB eacutetape 01dBDeacutelai Entreacutee 0 a 729mS eacutetape 01 mS
Sortie 0 a 340mS eacutetape 01mSRotation de phase 0deg - 180deg
COMPRESSIONSeuil -80dB a +20dB eacutetape 01dBRapport 11 a Inf1 eacutetape 001Gain agrave la sortie 0dB a 40dB eacutetape 01dBTemps dattaque 1mS a 1000mS eacutetape 01mSTemps de relacircchement 1mS a 1000mS eacutetape 01mSTemps de maintien 1mS a 1000mS eacutetape 01mS
EGALISEURS12 eacutegaliseurs pour chaque entreacutee et sortieType PEQ (parameacutetrique) Hi-shelf Lo-sheft
Freacutequence 20Hz a 20KHz eacutetape 1HzGain -30dB a +15dB eacutetape 001dBBande 005dB a 2dB eacutetape 001dB (uniquement pour PEQ)
FILTRES CROSSOVERFiltre Linkwitz Riley
Type HF high-shelfLF low-shelf
Pente 12dBoct - 24dBoct - 48dBoctFreacutequence de coupure 5Hz a 20KHz eacutetape 1Hz
ALIMENTATION Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)POIDS 19Kg
Remarques Speacutecifications sujettes agrave modifications sans preacuteavis
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
2 VIE ATTIVO2 WAY ACTIVE
3 VIE PASSIVO3 WAY PASSIVE
L
L
A
A
HIGH L
MID L
LOW HIGHMID RHIGHMID L
LOW L
HIGH R
MID R
LOW R
R
R
B
B
1
1
2
2
3
3
456
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
Menu Matrix configurationMatrix
57 58
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
EROUIG ATRIX TNM
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
OU
TP
UT
1
OU
TP
UT
2
OU
TP
UT
3
OU
TP
UT
4
OU
TP
UT
5
OU
TP
UT
6
AE
S-E
BU
OU
TP
UT
INP
UT
A
AE
S-E
BU
INP
UT
INP
UT
B
D D D D D D
D D
A A A A A A
A SA
MP
LE
RA
TE
CO
NV
A
LIN
KA
BL
E
SC
HE
MA
A B
LO
CC
HI -
BL
OC
K D
IAG
RA
MB
LO
CK
SC
HA
LT
BIL
D -
SC
HE
MA
S F
ON
CT
ION
NE
LS
LINE ARRAY SUB MONO ATTIVO
LINE ARRAY SUB MONO ACTIVEINGRESSI - INPUT
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
L
L
L
A
A
A
AESEBU IN
AESEBU IN
AESEBU IN
AESEBU OUT
AESEBU IN
AESEBU IN
AESEBU OUT
R
R
R
LR
B
B
B
123456
HIGHMID L
HIGHMID L HIGHMID R
HIGHMID R
LOW L LOW R
LAYER
DISPLAY MEMORY
FADER MODE
LAYER
DISPLAY MEMORY
FADER MODE
Ingresso ANALOGICO
ANALOG Input
Collegamento in cascata
Link connections
Ingresso DIGITALE
DIGITAL inputA B
BALANCED AUDIO INPUTS
-6dB
PUSH PUSH
IN OUT
AES EBUPUSH
Oppure
or
Oppure
or
Menu Option configurationOption
Menu Option configurationOption Menu Option configurationOption
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type Analog
AES out An In
Input type Analog
AES out An In
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
59 60
InA-B Src Dig InInA-B Src Dig InInA-B Src An InInA-B Src An In
frequenzaHz
dB
Gu
ad
ag
no
60 200 2800
0dB0dB
-6dB
Esempio di un sistema a 3-vie
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
Out 1 Out 2 Out 3
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Esempio di un sistema a 3-vie
61 62
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
26NAC 26NAC
R TE
DO
R
MO LEU O R CE S
E O TR L A
S O
O C ND I P
P hsuernE t
o su cti nF nel rS e tc o
E CSME UN
IGCHTE OL SN EOBd
ocaL l
M
0
484
467
430
44
31
75
12
7
DIMENSIONI DIMENSIONSABMESSUNGEN DIMENSIONS
BESCHREIBUNG DES MENUumlFENSTERS X-Over
Dieses Fenster erlaubt fuumlr jeden Ausgang einen Bassdurchgangsfilter einen Hochdurchgangsfilter oder mittels Kombination von beiden einen Banduumlbergangsfilter zu waumlhlenDer Filter ist ein Linkwitz-Riley wo man die Neigung von 12 dBoct 24dBoct oder 48 dBoct und die entsprechende Schnittfrequenz auswaumlhlen kann
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) AUSGANGSKANAumlLE
Die Steckverbinder am Ausgang werden mit denselben Angaben auf dem Siebdruck auf der Ruumlckseite der Vorrichtung identifiziert
b) FILTER CROSSOVERDen Filter nach Bedarf waumlhlen Man kann folgendes auswaumlhlen
Dis Kein Filter aktiviert
HP Hochdurchgangsfilter nur den Teil des Audiosignals durchlassen der uumlber der Schnittfrequenz liegt
LP Bassdurchgangsfilter nur den Teil des Audiosignals durchlassen der unter der Schnittfrequenz liegt
Filter-Konfiguration Tiefpass Hochpass
Nichts Dis Dis
Hochpass HP Dis
Tiefpass Dis LP
Bandpass HP LP
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
12dBoct
24dBoct
frequenza Hz
dB
Gu
ad
ag
no
48dBoct
c) DAumlMPFUNGSNEIGUNGDie Daumlmpfungsneigung des Audiosignals auf der Basis der Verringerung auswaumlhlen die man erreichen moumlchte Je houmlher die Daumlmpfungsneigung bei gleicher Schnittfrequenz desto groumlszliger ist die Signalauswahl Man kann folgendes waumlhlen
12 entsprechend 12 dboct
24 entsprechend 24 dboct
48 entsprechend 48 dboct
d) SCHNITTFREQUENZErlaubt die Durchgangsfrequenz der niederen Frequenzen (Bassdurchgangsfilter) oder der hohen Frequenzen (Hochdruchgangsfilter) einzustellenDie Auswahl des Schnitts bezieht sich auf die Wiedergabe die man erreichen moumlchteDie benutzte Maszligeinheit ist Hz
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
frequenza
frequenza
Hz
Hz
dB
dB
Gu
ad
ag
no
Gu
ad
ag
no
f0
f0
0dB0dB
0dB
-6dB
-6dB
BESCHREIBUNG DES MENUumlFENSTERS Matrix
Erlaubt fuumlr jeden Ausgang das Eingangssignal zu waumlhlen das als Quelle benutzt werden soll
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) AUSGANGSKANAumlLEIdentifizierung des einzustellenden Ausgangskanals
b) IDENTIFIZIERUNG DER EINGAumlNGEDen Signaltyp auswaumlhlen der nach eigener Anforderung jedem einzelnen Ausgang zugeordnet werden soll Man kann folgendes waumlhlen
In A Das Signal wird dem Eingang A zugeordnet
In B Das Signal wird dem Eingang B zugeordnet
In A+B Zuordnung der a lgebra ischen Summe der be iden Eingangssignale A und B
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
BESCHREIBUNG DES MENUumlFENSTERS Option
Erlaubt die Anzeige der Systemeinstellungen wie die Zuordnung der Ein- und Ausgaumlnge Daumlmpfung Displaykontrast und Firmware-Version
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B Src
Diese Option erlaubt die Einstellung des Audio-Signaltyps am Eingang
Analoge Audiosignale (Eingaumlnge A und B)
Digitale Audiosignale (Eingang AESEBU)
DigOut Src
An In =Audiosignale an den analogen Eingaumlngen
Dig In =Audiosignale am digitalen Eingang
OUT 1-2 =Audiosignale an den Ausgaumlngen 1 und 2
OUT 3-4 =Audiosignale an den Ausgaumlngen 3 und 4
OUT 5-6 =Audiosignale an den Ausgaumlngen 5 und 6
Input Mode
An In
Dig In
Indip =
Linked =
Diese Option erlaubt die Audioquelle zu waumlhlen die fuumlr den Steckverbinder AESEBU OUT (digitaler Ausgang) bestimmt ist
Erlaubt die Eingaumlnge zu konfigurieren
Sie sind unabhaumlngig und selbststaumlndig sie unterliegen keinen Verpflichtungen untereinander Sie sind verbunden und funktionieren im Stereo-Modus
Die Kompressoren Filter Verzoumlgerungen die Lautstaumlrke sind bei beiden Kanaumllen identisch
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
39
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
40
Atten PadZeigt an wie der Wahlschalter -6 dB auf der Ruumlckseite eingestellt ist [Ref 5] Dieser Wahlschalter muss aktiviert werden wenn das Level an den analogen Eingaumlngen zu hoch ist Der Wahlschalter wird uumlber die Taste aktiviert im Menuuml gibt es nur eine Anzeige
0dB = Wahlschalter nicht aktiviert
-6dB = Wahlschalter aktiviert
Contrast
10 heller 60 dunkler 100
Fw Vers
Die Eingangssignale sind dieselben wie die Eingangsquelle
Die Eingangssignale werden vom internen Prozessor um -6 dB gedaumlmpft
Erlaubt den Kontrast des LCD-Displays einzustellen um den Unterschied der Helligkeit auf den Installationsort auszurichten Ein deutlicheres Display erlaubt auf korrekte und schnelle Weise innerhalb der Menuumls zu surfenDie Hersteller-Einstellung am Ausgang liegt bei 60
Zeigt die Firmware-Version des Prozessors an
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
41
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
42
TECHNISCHE DATEN
Antwort in FrequenzDynamische GammaCMMRCrosstalkDistorsion
ProzessorFrequenz der DatenausarbeitungAnaloge Converter Verzoumlgerung der VerteilungSpeicherung der Konfigurationen
DisplayTastenBedienungen
Analoger Eingang ndeg2 x XLR (3-poliger Female Stecker)Impedanz des Eingangs gt10KOhmMaximales Level +21dBu ohne PAD
+27dBu bei PAD
Impedanz des Ausgangs 50OhmMaximales Level +21dBu Typ symmetrisch
Typ SPDIF-AESEBU (AES3)
Typ Entsprechend dem Standard des Eingang
Typ
Typ
NETZSPANNUNGABMESSUNGEN (BXHXT)GEWICHT
AUDIO-LEISTUNGEN+- 01dB (20 to 30kHz)116dB typgt 60dB (50 to 10kHz)lt -100dB0002 (1kHz +4dBu)
DIGITALE AUDIO-LEISTUNGEN DSP 2856-bit 48KHz24-bit BURR BROWN15ms32 preset
KONTROLLEN LCD GrafikESC - MENU - FUNCTIONS SELECTIONENTER
EIN-AUSGAumlNGE
Analoger Ausgang ndeg6 x XLR (3-poliger Male Stecker)
Digitaler Eingang ndeg1x XLR (3-poliger female Stecker)
Digitaler Ausgang ndeg1x XLR (3-poliger Male Stecker)
Ein-Ausgang Rdnet ndeg2 x XLR RJ45 (kabel CAT 5) USB Typ B
KONTROLLPARAMETER AUDIOStaumlrke -80dB a +20dB step 01dBVerzoumlgerung Eingang 0 a 729mS step 01 mS
Ausgang 0 a 340mS step 01mSPhasenrotation 0deg - 180deg
KOMPRESSIONSchwelle -80dB a +20dB step 01dBVerhaumlltnis 11 a Inf1 step 001Staumlrke am Ausgang 0dB a 40dB step 01dBAnschlusszeit 1mS a 1000mS step 01mSReleasezeit 1mS a 1000mS step 01mSBeibehaltungszeit 1mS a 1000mS step 01mS
EQUALIZER12 Equalizer fuumlr jeden Ein- und Ausgang
PEQ (parametrischer) Hi-shelf Lo-sheftFrequenz 20Hz a 20KHz step 1HzStaumlrke -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (lediglich PEQ)
FILTER CROSSOVERFilter Linkwitz Riley
HP HochdurchgangsfilterLP Bassdurchgangsfilter
Neigung 12dBoct - 24dBoct - 48dBoctSchnittfrequenz 5Hz a 20KHz step 1Hz
Full-range 100-240Vac 50-60Hz430482x43x130mm 19Kg
AnmerkungenSpezifikationen unterliegen Aumlnderungen ohne Vorankuumlndigung
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
INTRODUCTIONAC26N est un processeur audio numeacuterique pour la gestion de leacutequipement audio conccedilu pour des installations fixes et mobiles Il fonctionne selon une technologie de pointe avec des processeurs agrave 2856bits et des convertisseurs ADDA agrave 24-bits hautes performances Les fonctions du processeur sont les niveaux dentreacutee et de sortie le deacutelai (delay) la polariteacute 12 bandes deacutegalisation par canal dentreacutee et de sortie diffeacuterentes seacutelections de croisement (crossover) et un limiteur hautes performances Le controcircle des filtres a une reacutesolution de 1Hz Les entreacutees et les sorties peuvent ecirctre programmeacutees en plusieurs configurations pour satisfaire tous les besoins AC26N peut ecirctre controcircleacute en temps reacuteel et tous les paramegravetres peuvent ecirctre configureacutes depuis le pupitre frontale et par ordinateur avec interface graphique intuitive accessible via le logiciel laquoDVA Networkraquo et une connexion de reacuteseau deacutedieacutee RDnet ou USBLa mise agrave jour du logiciel pour lUniteacute centrale et DSP par ordinateur portable permet de maintenir le dispositif actualiseacute Il est possible denregistrer et de rappeler 32 configurations preacute-eacutequipeacutees de configuration
Contenu de lemballage - AC26N - Mode demploi- CD logiciel- Cacircble dalimentation
Caracteacuteristiques- 2 entreacutees et 6 sorties avec adressage flexible- Entreacutee et sortie steacutereacuteo AESEBU adressables - DSP 2856-bit- Convertisseurs AD BURR BWOWN 24-bit hautes performances- Freacutequence de reacutesolution des filtres 1 Hz - 12 eacutegaliseurs parameacutetriques pour chaque entreacutee et sortie- 2 filtres de croisement par sortie avec pente seacutelectionnable agrave 122448dBoct- DRC agrave configuration multiple hautes performances pour configuration limiteur
compression pour chaque entreacutee et sortie- Niveau reacuteglable en dB polariteacute et deacutelai pour chaque entreacutee et sortie- Mise agrave jour du micrologiciel par lordinateur- Affichage graphique agrave cristaux liquides- 32 preacutereacuteglages enregistrables par lutilisateur- Interface USB pour le controcircle et la configuration par ordinateur- Interface RDnet permettant de controcircler jusquagrave 256 dispositifs agrave distance
PC
PC
RDNETcontrol(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FONCTIONS DE LA FACE AVANT
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
COMMANDES ET FONCTIONS1) AFFICHAGE
Laffichage graphique agrave cristaux liquides permet de visualiser et deacutediter les informations de lAC26N sans utiliser lordinateur Le contraste peut ecirctre configureacute dans le menu principal
2) MANETTE Functions Selector et Push EnterCe controcircle permet de se deacuteplacer de seacutelectionner et de modifier les paramegravetres dans les menus affichables agrave leacutecranRotation de la manette (Functions Selectors)- permet de se deacuteplacer sur les diffeacuterentes pages du menu - permet de modifier les paramegravetres seacutelectionneacutesPression de la manette (Push Enter)- permet de seacutelectionnervalider les paramegravetres
3) Bouton ESC Ce controcircle permet de quitter les menus afficheacutes ou de revenir agrave la visualisation preacuteceacutedente
4) Bouton Menu Ce controcircle permet dacceacuteder directement au menu principal
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
Fra
nccedilais
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
43
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
Fra
nccedilais
44
DVA Network
AC26N est eacutequipeacute dune interface de reacuteseau proprieacutetaire deacutenommeacutee RDNET au moyen de laquelle il est possible de sinterfacer agrave lordinateur agrave travers un peacuteripheacuterique (RDNET control)
Pour cela un protocole de communication a eacuteteacute deacuteveloppeacute avec lequel il est possible de recevoir et denvoyer les donneacutees ce branchement permet de faire le monitorage en temps reacuteel des paramegravetres du diffuseur comme puissance de sortie tempeacuterature de lamplificateur eacutetat du limiteur etc Il est aussi possible de seacutelectionner diffeacuterentes eacutegalisations ou den creacuteer de nouvelles et de reacutegler les niveaux de volume souhaiteacutes au moyen dun plug-in approprieacute
On conseille de teacuteleacutecharger gratuitement le logiciel DVA Network directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
DVA USB Manager
On conseille de teacuteleacutecharger gratuitement le logiciel DVA USB Manager directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
Le micrologiciel du module amplificateur peut ecirctre remis agrave jour par le port USBPour rendre cette mise agrave jour possible et facile un programme speacutecifique a eacuteteacute deacuteveloppeacute
DOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
CONNEXIONS DU PANNEAU ARRIEgraveRE
1586 75 141210 11 13 169 17
14) Connecteur ldquo USBrdquoCe connecteur USB (type B) permet de connecter le processeur agrave un ordinateur pour le controcircle et la mise agrave jour du micrologiciel via un programme deacutedieacute (DVA Network)
15) PRISE DALIMENTATION MAINSPermet la connexion du cacircble dalimentation fourni de seacuterie
16) PORTE-FUSIBLE FUSELogement pour fusible de ligne
17) INTERRUPTEUR GENERAL POWERLinterrupteur permet de mettre en marche ou deacuteteindre le controcircleur audio
COMMANDES ET FONCTIONS
5) SELECTEUR ldquo-6dBrdquoLe seacutelecteur permet de reacuteduire de 6dB les niveaux dentreacutee analogiques XLR [6] tout en compensant les niveaux eacuteleveacutes de sortie des meacutelangeurs ou dautres dispositifs audio Quand la barre du niveau de signal des entreacutees sur laffichage [1] reste au maximum cela indique que le niveau du signal entrant est eacuteleveacute Il est alors conseilleacute dutiliser latteacutenuation -6dBIl est possible de veacuterifier quand le seacutelecteur est activeacute par le menu Option
6) CONNECTEURS DENTREE ldquoArdquo ET ldquoBrdquoEntreacutees eacutequilibreacutees au niveau de la ligneIls sont en mesure daccepter des connecteurs XLR macircles
7) CONNECTEURS DE SORTIE ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo ET ldquo6rdquoSorties eacutequilibreacutees au niveau de la ligne Ils sont en mesure daccepter des connecteurs XLR femelles
Prendre garde agrave brancher convenablement les sorties sur les diffuseurs ou les amplificateurs en fonction des configurations de chaque canal pour eacuteviter des deacutegacircts et des problegravemes de fonctionnement
Section ldquoAESEBUrdquo
8) CONNECTEUR DENTREE INOutre les entreacutees audio analogiques une entreacutee audio numeacuterique SPDIF-AESEBU (AES3) a eacuteteacute preacutevue et peut ecirctre seacutelectionneacutee par le menu de setupLentreacutee requiert une connexion eacutequilibreacutee en utilisant un connecteur XLR avec un cacircble agrave 3 conducteurs de 110ohm torsadeacute
9) CONNECTEUR DE SORTIE OUTCe connecteur permet de relancer le signal audio dans les entreacutees analogiques ou numeacuteriques ou sur les sorties La source doit ecirctre reacutegleacutee par le menu OptionLa connexion sera conforme agrave la mecircme norme que lentreacutee [reacutef8]
Section ldquoRDNETrdquo
10) CONNECTEUR DENTREE DATA INPUTConnecteur RJ45 entreacutee de donneacutees
11) CONNECTEUR DE SORTIE DATA LINKConnecteur RJ45 sortie de donneacutees pour la connexion de seacuterie en cascade
12) VOYANT LUMINEUX ONCe voyant de couleur verte sallume uniquement quand lAC26N a reconnu et est connecteacute agrave luniteacute principale RDNET par lordinateur
13) VOYANT LUMINEUX ACTIVECe voyant de couleur jaune clignote quand une transmission des donneacutees est active entre RDNET et le dispositif
PUSH
P SHU
SHPU
P SHU
PUSH
CONNEXIONS
Audio analogiquesLes connexions eacutequilibreacutees permettent de reacuteduire au minimum le bruit provoqueacute par les cacircbles et dutiliser de longs cacircblesCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLe connecteur XLR doit ecirctre brancheacute avec la broche 1 agrave la masse la broche 2 au chaud (+) et la broche 3 au froid (-) En cas de cacircble blindeacute brancher le blindage agrave la broche 1Les cacircbles de connexion XLR-XLR et XLR-Jack14(63mm) peuvent semployer pour la connexion agrave lAC26N
12
3
Entreacutee
Entreacutee
XLR - femme
XLR - femme
1 2
3
Sortie
Sortie
XLR - Macircle
XLR - Macircle
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2 = Point chaudPhase +VE
Broche 3 =Point froidPhase -VE
Broche 3 =Point froidPhase -VE
Anneau
Manchon
Pointe Point chaudPhase +VE
Anneau = Point froidPhase -VE
ManchonB Masselindeacute
Pointe
Les connexions deacuteseacutequilibreacutees peuvent semployer mecircme si le bruit provoqueacute par les cacircbles augmente Les cacircbles ne peuvent deacutepasser 5m de longCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLes connexions deacuteseacutequilibreacutees peuvent abaisser le niveau du signal entrant de 6dB Pour remeacutedier agrave cet inconveacutenient il faut brancher la broche 3 agrave la masse mecircme si cela augmente le bruit
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
45
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
46
12
3
1 2
3
Pointe Manchon
Pointe = Signal
Broche 3 = Link to Pin 1
Broche 3 = Link to Pin 1
ManchonB Masselindeacute
Audio numeacuteriques (AESEBU)
AESEBU (protocole AES3) est une entreacutee eacutequilibreacutee isoleacutee eacutelectriquement agrave laide dun transformateur Elle permet demployer deux canaux audio dans un seul cacircble bipolaire blindeacute Les caracteacuteristiques du cacircble doivent ecirctre de 3 pocircles impeacutedance 100ohm torsadeacute et blindeacute avec connecteur XLR (AES3 standard)
RJ 45
|1|2|3|4|5|6|7|8|
RDnet
Chaque port RDNet des Control 2 et Control 8 peut ecirctre brancheacute agrave un maximum de 32 dispositifs compatibles placeacutes en cascade Dans lexemple suivant le port de luniteacute de controcircle RDNET CONTROL 2 est relieacute agrave lentreacutee DATA INPUT dun AC26N dont la sortie parallegravele DATA LINK est envoyeacutee agrave lentreacutee de lAC26N successif Dans lexemple [n] est un nombre compris entre 3 et 32 (limite maximale des dispositifs que lon peut relier agrave un sous-reacuteseau)
La longueur totale du cacircble CAT5 dun sous-reacuteseau NE peut PAS deacutepasser 900 megravetres
Le connecteur doit ecirctre relieacute comme 1 ndash disponible pour dautres fonctions (par exemple audio +) 2 ndash disponible pour dautres fonctions (par exemple audio )3 ndash disponible pour dautres fonctions (par exemple masse analogique)4 ndash masse numeacuterique5 ndash masse numeacuterique6 ndash disponible pour dautres fonctions (par exemple alimentation)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
MISE EN MARCHE
Lors de la mise en marche du dispositif linitialisation deacutebute et dure quelques secondes Leacutecran affiche le modegravele le logo et la barre de progression du chargement du programme
En fin de processus dinstallation leacutecran affiche la fenecirctre du menu Meters Pour connaicirctre les indications en deacutetail consulter le paragraphe DESCRIPTION FENETRE MENU Meters
LAC26N est precirct agrave lemploi
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION ET VISUALISATION
Pour entrer dans la fenecirctre du menu principal il faut pousser sur la touche MENU ( ) agrave lavant du dispositifDune page quelconque du menu en poussant sur la touche ESCrdquo ( ) on revient automatiquement sur la page-eacutecran preacuteceacutedente
MENU PRINCIPAL
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Le processeur contient six menus Ils montrent etou configurent les paramegravetres du systegravemeLes menus principaux sont
Meters Visualisation des niveaux des entreacutees et des sorties visualisation du programme utiliseacute et eacutetat mute rapide
Preset Meacutemoriser enregistrer et eacuteliminer les configurations du systegraveme
Matrix seacutelectionner les sorties en fonction du signal entrant
Ch Job configuration de chaque signal
X-Over configurer les freacutequences de coupure et les types de filtres pour chaque sortie
Option attribution des entreacutees et des sorties contraste daffichage la version du micrologiciel les entreacutees et dautres options
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
47
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
48
DESCRIPTION DE LA FENETRE MENU Metersrdquo
Cette fenecirctre permet de visualiser les configurations et leacutetat geacuteneacuteral des entreacutees et des sorties la version du programme utiliseacute son eacutetat et le mode de pilotage du systegraveme
Les menus et les options afficheacutees peuvent se seacutelectionner en tournant la manette ldquoFUNCTIONS SETECTORrdquo ( ) Pour avoir accegraves agrave linteacuterieur de la seacutelection il faut mettre le paramegravetre souhaiteacute en eacutevidence et pousser sur la manette ldquoPush Enterrdquo ( | ) Il faut en faire de mecircme pour seacutelectionner etou modifier les options dans les commandes du menu
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositifAvec des signaux dentreacutee numeacuteriques les indications ldquoArdquo et ldquoBrdquo correspondent agrave lentreacuteeEn tournant la manette ldquoFUNCTIONS SELECTORrdquo [2] on fait deacutefiler en mode cyclique les canaux dentreacutee de sortie et lindication de mute geacuteneacuteral (d) le canal seacutelectionneacute est mis en eacutevidence
b) BARRE DE NIVEAU DE COMPRESSIONMUTE CANAL
COMPRESSION DE SIGNALLa compression du signal est visualiseacutee par le deacutefilement de la barre de droite de haut en bas
MUTE Chaque canal peut ecirctre placeacute en mute Seacutelectionner le canal et pousser sur la manette ldquoPush Enterrdquo [2] pour valider le changement deacutetat Lindication du canal sera remplaceacutee par la lettre M et la barre sera totalement mise en eacutevidencePour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterations
c) BARRE DE NIVEAU DE SIGNALLindication du niveau de chaque canal est signaleacutee par le deacutefilement de la barre de gauche
d) MUTE GENERALIl est possible de mettre simultaneacutement toutes les entreacutees et les sorties en mute Tourner la manette ldquoFUNCTIONS SELECTORrdquo seacutelectionner la lettre M et pousser sur la manette Push EnterPour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterationsLe mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) MODES DE COMMANDEIl affiche le mode dutilisation etou les dispositifs qui sont relieacutes agrave lAC26N
Local = utilisation autonome Aucune connexion agrave un dispositif exteacuterieur
NET = relieacute directement au reacuteseau deacutedieacute RDNet et agrave lordinateur
USB = relieacute directement agrave un ordinateur par cacircble USB
f) INDICATION DETAT DE PARAMETRAGECette indication permet de constater si un ou plusieurs paramegravetre(s) du programme chargeacute aont eacuteteacute modifieacute(s) par rapport au dernier sauvetage
= programme dorigine
= programme avec des paramegravetres modifieacutes
g) PROGRAMME CONFIGURELe chiffre indique le programme chargeacute et utiliseacute par le systegraveme agrave lemplacement de sauvetage Consulter le menu de Preset pour de plus amples deacutetails
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
DESCRIPTION DE LA FENETRE MENU Ch Job
Cette fenecirctre permet dafficher la configuration de chaque canal
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) NIVEAU DU SIGNALIndique le gain du signal Laugmentation de lintensiteacute dun signal est libelleacutee en deacutecibel (dB) Le paramegravetre peut ecirctre seacutelectionneacute de -8000dB agrave +2000dB avec des pas de 001dB Une augmentation de 6dB est eacutegale approximativement au redoublement agrave leacutechelle lineacuteaire du niveau du signal sous tensionAvec un gain supeacuterieur agrave 0dB le signal est amplifieacute tandis quavec un gain infeacuterieur agrave 0dB le signal est atteacutenueacute
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
49
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
50
c) DELAI DU SIGNAL (DELAY)Le signal audio reproduit peut ecirctre retardeacute pour permettre lalignement acoustique Cela compense les diffeacuterentes positions des diffuseurs pendant linstallation et la reproduction sonore Il se libelle en mS Le paramegravetre peut ecirctre seacutelectionneacute de 00mS agrave 729mS avec un pas de 01mSPour aligner un signal audio il est possible dutiliser la formule suivante
Deacutelai = (GAPx1000)344
Deacutelai = ms (en millisecondes)GAP = distance du diffuseur du point de reacutefeacuterence (en megravetres)Vitesse du son = 344ms
d) MUTEChaque canal peut ecirctre placeacute en mute La mecircme commande peut ecirctre activeacutee dans la fenecirctre du menu meters NB Le mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) PhasePermet la rotation de phase de 180deg par rapport au signal entrantCette rotation permet loptimisation surtout des basses freacutequences dans les installations complexes
f) EGALISATIONCette commande ouvre la fenecirctre du menu deacutegalisation de chaque canal Elle sert surtout pour corriger une ou plusieurs freacutequences qui doivent ecirctre atteacutenueacutees ou augmenteacutees
M M
LAC26N gegravere 12 filtres par canal dentreacutee et sortie avec trois types de configurations diffeacuterentes - Leacutegaliseur PEQ (peaking equalizer) est ideacuteal pour identifier isoler et
corriger une seule plage de freacutequences bien deacutetermineacutee Toutes les freacutequences passent mais il augmente ou diminue uniquement celles autour de la freacutequence centrale pour une bande preacutecise et un gain deacutefini
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessus de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessous de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
f Numeacuterotation des 12 filtres disponibles pour cette entreacutee ou cette sortie1
f Le type de filtre est afficheacute 2
Dis Deacutesactiveacute (absent)
PEQ Peaking equlizer
Sh H Filtre high-shelf
Sh L Filtre high-shelf
Exemples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
REMARQUELe paramegravetre Bw deacutetermine le champ de freacutequences adjacent agrave la freacutequence configureacutee ougrave est activeacute le filtre Plus la valeur Bw est eacuteleveacutee plus vaste est le champ de freacutequences (1Bw=1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONCette commande ouvre la fenecirctre du menu de compression de chaque canal
g1) TresholdIdentifie le seuil ougrave commence le rapport de compression La valeur de base 11
g2) RatioIndique le rapport de conversion entre le signal entrant et le signal sortant
g3) Post Gain Attach Release HoldCes donneacutees deacutependent du rapport de conversion que lon veut obtenir - Post Gain est le gain de sortie- Attack est le temps dattaque - Release est le temps de relacircchement- Hold est le temps de maintien
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
52
DESCRIPTION DE LA FENETRE MENU Preset
Cette fenecirctre permet de meacutemoriser jusquagrave 32 configurations dans lAC26NLe fabricant fournit le systegraveme avec un programme configureacute et enregistreacute en position 0 et non susceptible deacutecrasement
032 Elle indique lemplacement de sauvetage de la configurationCe numeacutero apparaicirct dans la fenecirctre Meters en position (g) A tout moment le programme utiliseacute peut ecirctre afficheacute par lutilisateur
Empty Preset Cest le nom qui est associeacute au numeacutero de lemplacement quand aucune configuration (vide) nest enregistreacutee
Local preset Local preset est le nom qui est associeacute au numeacutero de lemplacement quand on enregistre une configuration NB = Il est possible denregistrer une configuration avec lenom souhaiteacute de 16 lettres tout au plus agrave condition que lonutilise linterface via lordinateur
Le nom du programme assigneacute est indiqueacutePour toucher agrave lapplication 3 choix soffrent agrave vous
Save Le programme est enregistreacute en meacutemoire de lAC26N
Del Le programme est effaceacute
Load Le programme est chargeacute et precirct agrave lemploi
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
51
DESCRIPTION DE LA FENETRE MENU X-Over
Cette fenecirctre permet de seacutelectionner un filtre passe bas un filtre passe haut ou par la combinaison des deux de creacuteer un filtre passe bande pour chaque sortieLe filtre actif est un Linkwitz-Riley qui permet de seacutelectionner la pente de 12dBoct 24dBoct ou 48dBoct et sa freacutequence de coupure
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) CANAUX DE SORTIE
Les connecteurs de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) FILTRE CROSSOVERSeacutelectionner le filtre selon les besoins Il est possible de seacutelectionner
Dis Aucun filtre activeacute
HP Filtre passe-haut laisse passer uniquement la partie de signal audio supeacuterieure agrave la freacutequence de coupure
LP Filtre passe-bas laisse passer uniquement la partie de signal audio infeacuterieure agrave la freacutequence de coupure
Configuration du filtre Passe-haut Passe-bas
Rien Dis Dis
Passe-haut HP Dis
Passe-bas Dis LP
Passe-bande HP LP
12dBoct
24dBoct
Hz
dB
Ga
in 48dBoct
12dBoct
24dBoct
Hz
dB
Ga
in
48dBoct
c) PENTE DATTENUATIONSeacutelectionner la pente datteacutenuation du signal audio en fonction de la diminution que lon veut obtenir Plus la pente datteacutenuation est eacuteleveacutee agrave eacutegaliteacute de freacutequence de coupure plus eacuteleveacutee sera la seacutelection du signal Il est possible de seacutelectionner
12 correspond agrave 12dboct
24 correspond agrave 24dboct
48 correspond agrave 48dboct
d) FREQUENCE DE COUPUREElle permet de reacutegler la freacutequence de passage des freacutequences infeacuterieures (filtre passe-bas) ou des freacutequences supeacuterieures (filtre passe-haut) uniquementLe choix de la coupure deacutepend de la reproduction que lon veut obtenirLuniteacute de mesure utiliseacutee est lHz
Hz
Hz
dB
dB
Ga
in
f0
f0
0dB0dB
0dB
-6dB
freacutequence
freacutequence
freacutequence
freacutequence
Ga
in
f0
0dB
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
53
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
54
DESCRIPTION DE LA FENETRE MENU Matrix
Elle permet de seacutelectionner le signal entrant agrave utiliser comme source pour chaque sortie
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) CANAUX DE SORTIEIdentification du canal sortant agrave reacutegler
b) IDENTIFICATIONS DES ENTREESSeacutelectionner le type de signal agrave associer agrave chaque sortie en fonction des besoins Il est possible de seacutelectionner
In A Le signal entrant A est associeacute
In B Le signal entrant B est associeacute
In A+B La somme algeacutebrique des deux signaux entrants A et B est associeacutee
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
DESCRIPTION DE LA FENETRE MENU Option
Permet dafficher les reacuteglages du systegraveme comme lassignation des entreacutees et des sorties latteacutenuation le contraste de laffichage et la version du logiciel
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcCette option permet de reacutegler le type de signal audio entrant
An In =signaux audio analogiques (entreacutees ldquoArdquo et ldquoBrdquo)
Dig In =signaux audio numeacuteriques (entreacutee AESEBU)
DigOut SrcCette option permet de seacutelectionner la source audio qui sera adresseacutee sur le connecteur AESEBU OUT (sortie numeacuterique)
An In = signaux audio des entreacutees analogiques
Dig In =signaux audio sur lentreacutee numeacuterique
OUT 1-2 = signaux audio sur les sorties 1 et 2
OUT 3-4 = signaux audio sur les sorties 3 et 4
OUT 5-6 = signaux audio sur les sorties 5 et 6
Input ModePermet de configurer les entreacutees
Indip = sont indeacutependantes et autonomes Ne sont soumises agrave aucun type de lien
Linked = sont unies et fonctionnent en mode steacutereacuteo Les compresseurs les filtres les deacutelais le volume sont identiques pour les deux canaux
Atten PadIndique le mode de reacuteglage du seacutelecteur ldquo-6dBrdquo placeacute agrave larriegravere [reacutef 5] Il faut activer ce seacutelecteur quand les niveaux dentreacutee analogiques sont trop eacuteleveacutes Le seacutelecteur sactive uniquement par le bouton Dans le menu il sagit dune simple visualisation
0dB = seacutelecteur non activeacute Les signaux dentreacutee sont identiques agrave la source entrante
-6dB = seacutelecteur activeacute Les signaux entrants sont atteacutenueacutes de -6dB par le processeur interne
ContrastIl permet de reacutegler le contraste de laffichage agrave cristaux liquides pour compenser la diffeacuterence de luminositeacute avec le lieu dinstallation Une plus grande clarteacute de laffichage permet de naviguer convenablement et rapidement dans les menusLe reacuteglage agrave la sortie de lusine du fabricant est de 60
10 plus clair 60 plus fonceacute 100
Fw VersIndique la version du logiciel du processeur
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
55
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
56
DONNES TECHINIQUES
PERFORMANCES AUDIOReacuteponse en freacutequence +- 01dB (20 to 30kHz)Plage dynamique 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsion 0002 (1kHz +4dBu)
PERFORMANCES AUDIO NUMERIQUES Processeur DSP 2856-bit Freacutequence de traitement des donneacutees 48KHzConvertisseurs analogiques 24-bit BURR BROWNDeacutelai de propagation 15msMeacutemorisations des configurations 32 preset
CONTROLES Affichage LCD graficoBoutonsCommandes ESC - MENU - FUNCTIONS SELECTION
ENTERENTREESSORTIESEntreacutee analogique ndeg2 x XLR (3 broches femelle)
Impeacutedance dentreacutee gt10KOhmNiveau maximum +21dBu senza PAD
+27dBu con PADSortie analogique ndeg6 x XLR (3 broches macircle )
Impeacutedance de sortie 50OhmNiveau maximum +21dBuType Balanceacute
Entreacutee numeacuterique ndeg1x XLR (3 broches femelle)Type SPDIF-AESEBU (AES3)
Sortie numeacuterique ndeg1x XLR (3 broches macircle )Type conforme agrave la norme de lentreacutee
EntreacuteesSortie Rdnet ndeg2 x XLR RJ45 (cacircble CAT 5)USB Type B
PARAMETRES DE CONTROLE DU SONGain -80dB a +20dB eacutetape 01dBDeacutelai Entreacutee 0 a 729mS eacutetape 01 mS
Sortie 0 a 340mS eacutetape 01mSRotation de phase 0deg - 180deg
COMPRESSIONSeuil -80dB a +20dB eacutetape 01dBRapport 11 a Inf1 eacutetape 001Gain agrave la sortie 0dB a 40dB eacutetape 01dBTemps dattaque 1mS a 1000mS eacutetape 01mSTemps de relacircchement 1mS a 1000mS eacutetape 01mSTemps de maintien 1mS a 1000mS eacutetape 01mS
EGALISEURS12 eacutegaliseurs pour chaque entreacutee et sortieType PEQ (parameacutetrique) Hi-shelf Lo-sheft
Freacutequence 20Hz a 20KHz eacutetape 1HzGain -30dB a +15dB eacutetape 001dBBande 005dB a 2dB eacutetape 001dB (uniquement pour PEQ)
FILTRES CROSSOVERFiltre Linkwitz Riley
Type HF high-shelfLF low-shelf
Pente 12dBoct - 24dBoct - 48dBoctFreacutequence de coupure 5Hz a 20KHz eacutetape 1Hz
ALIMENTATION Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)POIDS 19Kg
Remarques Speacutecifications sujettes agrave modifications sans preacuteavis
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
2 VIE ATTIVO2 WAY ACTIVE
3 VIE PASSIVO3 WAY PASSIVE
L
L
A
A
HIGH L
MID L
LOW HIGHMID RHIGHMID L
LOW L
HIGH R
MID R
LOW R
R
R
B
B
1
1
2
2
3
3
456
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
Menu Matrix configurationMatrix
57 58
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
EROUIG ATRIX TNM
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
OU
TP
UT
1
OU
TP
UT
2
OU
TP
UT
3
OU
TP
UT
4
OU
TP
UT
5
OU
TP
UT
6
AE
S-E
BU
OU
TP
UT
INP
UT
A
AE
S-E
BU
INP
UT
INP
UT
B
D D D D D D
D D
A A A A A A
A SA
MP
LE
RA
TE
CO
NV
A
LIN
KA
BL
E
SC
HE
MA
A B
LO
CC
HI -
BL
OC
K D
IAG
RA
MB
LO
CK
SC
HA
LT
BIL
D -
SC
HE
MA
S F
ON
CT
ION
NE
LS
LINE ARRAY SUB MONO ATTIVO
LINE ARRAY SUB MONO ACTIVEINGRESSI - INPUT
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
L
L
L
A
A
A
AESEBU IN
AESEBU IN
AESEBU IN
AESEBU OUT
AESEBU IN
AESEBU IN
AESEBU OUT
R
R
R
LR
B
B
B
123456
HIGHMID L
HIGHMID L HIGHMID R
HIGHMID R
LOW L LOW R
LAYER
DISPLAY MEMORY
FADER MODE
LAYER
DISPLAY MEMORY
FADER MODE
Ingresso ANALOGICO
ANALOG Input
Collegamento in cascata
Link connections
Ingresso DIGITALE
DIGITAL inputA B
BALANCED AUDIO INPUTS
-6dB
PUSH PUSH
IN OUT
AES EBUPUSH
Oppure
or
Oppure
or
Menu Option configurationOption
Menu Option configurationOption Menu Option configurationOption
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type Analog
AES out An In
Input type Analog
AES out An In
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
59 60
InA-B Src Dig InInA-B Src Dig InInA-B Src An InInA-B Src An In
frequenzaHz
dB
Gu
ad
ag
no
60 200 2800
0dB0dB
-6dB
Esempio di un sistema a 3-vie
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
Out 1 Out 2 Out 3
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Esempio di un sistema a 3-vie
61 62
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
26NAC 26NAC
R TE
DO
R
MO LEU O R CE S
E O TR L A
S O
O C ND I P
P hsuernE t
o su cti nF nel rS e tc o
E CSME UN
IGCHTE OL SN EOBd
ocaL l
M
0
484
467
430
44
31
75
12
7
DIMENSIONI DIMENSIONSABMESSUNGEN DIMENSIONS
Atten PadZeigt an wie der Wahlschalter -6 dB auf der Ruumlckseite eingestellt ist [Ref 5] Dieser Wahlschalter muss aktiviert werden wenn das Level an den analogen Eingaumlngen zu hoch ist Der Wahlschalter wird uumlber die Taste aktiviert im Menuuml gibt es nur eine Anzeige
0dB = Wahlschalter nicht aktiviert
-6dB = Wahlschalter aktiviert
Contrast
10 heller 60 dunkler 100
Fw Vers
Die Eingangssignale sind dieselben wie die Eingangsquelle
Die Eingangssignale werden vom internen Prozessor um -6 dB gedaumlmpft
Erlaubt den Kontrast des LCD-Displays einzustellen um den Unterschied der Helligkeit auf den Installationsort auszurichten Ein deutlicheres Display erlaubt auf korrekte und schnelle Weise innerhalb der Menuumls zu surfenDie Hersteller-Einstellung am Ausgang liegt bei 60
Zeigt die Firmware-Version des Prozessors an
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
41
De
uts
chD
eu
tsch
De
uts
chB
ed
ien
un
gs
an
leit
un
gB
ed
ien
un
gs
an
leit
un
g
42
TECHNISCHE DATEN
Antwort in FrequenzDynamische GammaCMMRCrosstalkDistorsion
ProzessorFrequenz der DatenausarbeitungAnaloge Converter Verzoumlgerung der VerteilungSpeicherung der Konfigurationen
DisplayTastenBedienungen
Analoger Eingang ndeg2 x XLR (3-poliger Female Stecker)Impedanz des Eingangs gt10KOhmMaximales Level +21dBu ohne PAD
+27dBu bei PAD
Impedanz des Ausgangs 50OhmMaximales Level +21dBu Typ symmetrisch
Typ SPDIF-AESEBU (AES3)
Typ Entsprechend dem Standard des Eingang
Typ
Typ
NETZSPANNUNGABMESSUNGEN (BXHXT)GEWICHT
AUDIO-LEISTUNGEN+- 01dB (20 to 30kHz)116dB typgt 60dB (50 to 10kHz)lt -100dB0002 (1kHz +4dBu)
DIGITALE AUDIO-LEISTUNGEN DSP 2856-bit 48KHz24-bit BURR BROWN15ms32 preset
KONTROLLEN LCD GrafikESC - MENU - FUNCTIONS SELECTIONENTER
EIN-AUSGAumlNGE
Analoger Ausgang ndeg6 x XLR (3-poliger Male Stecker)
Digitaler Eingang ndeg1x XLR (3-poliger female Stecker)
Digitaler Ausgang ndeg1x XLR (3-poliger Male Stecker)
Ein-Ausgang Rdnet ndeg2 x XLR RJ45 (kabel CAT 5) USB Typ B
KONTROLLPARAMETER AUDIOStaumlrke -80dB a +20dB step 01dBVerzoumlgerung Eingang 0 a 729mS step 01 mS
Ausgang 0 a 340mS step 01mSPhasenrotation 0deg - 180deg
KOMPRESSIONSchwelle -80dB a +20dB step 01dBVerhaumlltnis 11 a Inf1 step 001Staumlrke am Ausgang 0dB a 40dB step 01dBAnschlusszeit 1mS a 1000mS step 01mSReleasezeit 1mS a 1000mS step 01mSBeibehaltungszeit 1mS a 1000mS step 01mS
EQUALIZER12 Equalizer fuumlr jeden Ein- und Ausgang
PEQ (parametrischer) Hi-shelf Lo-sheftFrequenz 20Hz a 20KHz step 1HzStaumlrke -30dB a +15dB step 001dBBand 005dB a 2dB step 001dB (lediglich PEQ)
FILTER CROSSOVERFilter Linkwitz Riley
HP HochdurchgangsfilterLP Bassdurchgangsfilter
Neigung 12dBoct - 24dBoct - 48dBoctSchnittfrequenz 5Hz a 20KHz step 1Hz
Full-range 100-240Vac 50-60Hz430482x43x130mm 19Kg
AnmerkungenSpezifikationen unterliegen Aumlnderungen ohne Vorankuumlndigung
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
INTRODUCTIONAC26N est un processeur audio numeacuterique pour la gestion de leacutequipement audio conccedilu pour des installations fixes et mobiles Il fonctionne selon une technologie de pointe avec des processeurs agrave 2856bits et des convertisseurs ADDA agrave 24-bits hautes performances Les fonctions du processeur sont les niveaux dentreacutee et de sortie le deacutelai (delay) la polariteacute 12 bandes deacutegalisation par canal dentreacutee et de sortie diffeacuterentes seacutelections de croisement (crossover) et un limiteur hautes performances Le controcircle des filtres a une reacutesolution de 1Hz Les entreacutees et les sorties peuvent ecirctre programmeacutees en plusieurs configurations pour satisfaire tous les besoins AC26N peut ecirctre controcircleacute en temps reacuteel et tous les paramegravetres peuvent ecirctre configureacutes depuis le pupitre frontale et par ordinateur avec interface graphique intuitive accessible via le logiciel laquoDVA Networkraquo et une connexion de reacuteseau deacutedieacutee RDnet ou USBLa mise agrave jour du logiciel pour lUniteacute centrale et DSP par ordinateur portable permet de maintenir le dispositif actualiseacute Il est possible denregistrer et de rappeler 32 configurations preacute-eacutequipeacutees de configuration
Contenu de lemballage - AC26N - Mode demploi- CD logiciel- Cacircble dalimentation
Caracteacuteristiques- 2 entreacutees et 6 sorties avec adressage flexible- Entreacutee et sortie steacutereacuteo AESEBU adressables - DSP 2856-bit- Convertisseurs AD BURR BWOWN 24-bit hautes performances- Freacutequence de reacutesolution des filtres 1 Hz - 12 eacutegaliseurs parameacutetriques pour chaque entreacutee et sortie- 2 filtres de croisement par sortie avec pente seacutelectionnable agrave 122448dBoct- DRC agrave configuration multiple hautes performances pour configuration limiteur
compression pour chaque entreacutee et sortie- Niveau reacuteglable en dB polariteacute et deacutelai pour chaque entreacutee et sortie- Mise agrave jour du micrologiciel par lordinateur- Affichage graphique agrave cristaux liquides- 32 preacutereacuteglages enregistrables par lutilisateur- Interface USB pour le controcircle et la configuration par ordinateur- Interface RDnet permettant de controcircler jusquagrave 256 dispositifs agrave distance
PC
PC
RDNETcontrol(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FONCTIONS DE LA FACE AVANT
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
COMMANDES ET FONCTIONS1) AFFICHAGE
Laffichage graphique agrave cristaux liquides permet de visualiser et deacutediter les informations de lAC26N sans utiliser lordinateur Le contraste peut ecirctre configureacute dans le menu principal
2) MANETTE Functions Selector et Push EnterCe controcircle permet de se deacuteplacer de seacutelectionner et de modifier les paramegravetres dans les menus affichables agrave leacutecranRotation de la manette (Functions Selectors)- permet de se deacuteplacer sur les diffeacuterentes pages du menu - permet de modifier les paramegravetres seacutelectionneacutesPression de la manette (Push Enter)- permet de seacutelectionnervalider les paramegravetres
3) Bouton ESC Ce controcircle permet de quitter les menus afficheacutes ou de revenir agrave la visualisation preacuteceacutedente
4) Bouton Menu Ce controcircle permet dacceacuteder directement au menu principal
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
Fra
nccedilais
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
43
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
Fra
nccedilais
44
DVA Network
AC26N est eacutequipeacute dune interface de reacuteseau proprieacutetaire deacutenommeacutee RDNET au moyen de laquelle il est possible de sinterfacer agrave lordinateur agrave travers un peacuteripheacuterique (RDNET control)
Pour cela un protocole de communication a eacuteteacute deacuteveloppeacute avec lequel il est possible de recevoir et denvoyer les donneacutees ce branchement permet de faire le monitorage en temps reacuteel des paramegravetres du diffuseur comme puissance de sortie tempeacuterature de lamplificateur eacutetat du limiteur etc Il est aussi possible de seacutelectionner diffeacuterentes eacutegalisations ou den creacuteer de nouvelles et de reacutegler les niveaux de volume souhaiteacutes au moyen dun plug-in approprieacute
On conseille de teacuteleacutecharger gratuitement le logiciel DVA Network directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
DVA USB Manager
On conseille de teacuteleacutecharger gratuitement le logiciel DVA USB Manager directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
Le micrologiciel du module amplificateur peut ecirctre remis agrave jour par le port USBPour rendre cette mise agrave jour possible et facile un programme speacutecifique a eacuteteacute deacuteveloppeacute
DOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
CONNEXIONS DU PANNEAU ARRIEgraveRE
1586 75 141210 11 13 169 17
14) Connecteur ldquo USBrdquoCe connecteur USB (type B) permet de connecter le processeur agrave un ordinateur pour le controcircle et la mise agrave jour du micrologiciel via un programme deacutedieacute (DVA Network)
15) PRISE DALIMENTATION MAINSPermet la connexion du cacircble dalimentation fourni de seacuterie
16) PORTE-FUSIBLE FUSELogement pour fusible de ligne
17) INTERRUPTEUR GENERAL POWERLinterrupteur permet de mettre en marche ou deacuteteindre le controcircleur audio
COMMANDES ET FONCTIONS
5) SELECTEUR ldquo-6dBrdquoLe seacutelecteur permet de reacuteduire de 6dB les niveaux dentreacutee analogiques XLR [6] tout en compensant les niveaux eacuteleveacutes de sortie des meacutelangeurs ou dautres dispositifs audio Quand la barre du niveau de signal des entreacutees sur laffichage [1] reste au maximum cela indique que le niveau du signal entrant est eacuteleveacute Il est alors conseilleacute dutiliser latteacutenuation -6dBIl est possible de veacuterifier quand le seacutelecteur est activeacute par le menu Option
6) CONNECTEURS DENTREE ldquoArdquo ET ldquoBrdquoEntreacutees eacutequilibreacutees au niveau de la ligneIls sont en mesure daccepter des connecteurs XLR macircles
7) CONNECTEURS DE SORTIE ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo ET ldquo6rdquoSorties eacutequilibreacutees au niveau de la ligne Ils sont en mesure daccepter des connecteurs XLR femelles
Prendre garde agrave brancher convenablement les sorties sur les diffuseurs ou les amplificateurs en fonction des configurations de chaque canal pour eacuteviter des deacutegacircts et des problegravemes de fonctionnement
Section ldquoAESEBUrdquo
8) CONNECTEUR DENTREE INOutre les entreacutees audio analogiques une entreacutee audio numeacuterique SPDIF-AESEBU (AES3) a eacuteteacute preacutevue et peut ecirctre seacutelectionneacutee par le menu de setupLentreacutee requiert une connexion eacutequilibreacutee en utilisant un connecteur XLR avec un cacircble agrave 3 conducteurs de 110ohm torsadeacute
9) CONNECTEUR DE SORTIE OUTCe connecteur permet de relancer le signal audio dans les entreacutees analogiques ou numeacuteriques ou sur les sorties La source doit ecirctre reacutegleacutee par le menu OptionLa connexion sera conforme agrave la mecircme norme que lentreacutee [reacutef8]
Section ldquoRDNETrdquo
10) CONNECTEUR DENTREE DATA INPUTConnecteur RJ45 entreacutee de donneacutees
11) CONNECTEUR DE SORTIE DATA LINKConnecteur RJ45 sortie de donneacutees pour la connexion de seacuterie en cascade
12) VOYANT LUMINEUX ONCe voyant de couleur verte sallume uniquement quand lAC26N a reconnu et est connecteacute agrave luniteacute principale RDNET par lordinateur
13) VOYANT LUMINEUX ACTIVECe voyant de couleur jaune clignote quand une transmission des donneacutees est active entre RDNET et le dispositif
PUSH
P SHU
SHPU
P SHU
PUSH
CONNEXIONS
Audio analogiquesLes connexions eacutequilibreacutees permettent de reacuteduire au minimum le bruit provoqueacute par les cacircbles et dutiliser de longs cacircblesCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLe connecteur XLR doit ecirctre brancheacute avec la broche 1 agrave la masse la broche 2 au chaud (+) et la broche 3 au froid (-) En cas de cacircble blindeacute brancher le blindage agrave la broche 1Les cacircbles de connexion XLR-XLR et XLR-Jack14(63mm) peuvent semployer pour la connexion agrave lAC26N
12
3
Entreacutee
Entreacutee
XLR - femme
XLR - femme
1 2
3
Sortie
Sortie
XLR - Macircle
XLR - Macircle
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2 = Point chaudPhase +VE
Broche 3 =Point froidPhase -VE
Broche 3 =Point froidPhase -VE
Anneau
Manchon
Pointe Point chaudPhase +VE
Anneau = Point froidPhase -VE
ManchonB Masselindeacute
Pointe
Les connexions deacuteseacutequilibreacutees peuvent semployer mecircme si le bruit provoqueacute par les cacircbles augmente Les cacircbles ne peuvent deacutepasser 5m de longCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLes connexions deacuteseacutequilibreacutees peuvent abaisser le niveau du signal entrant de 6dB Pour remeacutedier agrave cet inconveacutenient il faut brancher la broche 3 agrave la masse mecircme si cela augmente le bruit
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
45
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
46
12
3
1 2
3
Pointe Manchon
Pointe = Signal
Broche 3 = Link to Pin 1
Broche 3 = Link to Pin 1
ManchonB Masselindeacute
Audio numeacuteriques (AESEBU)
AESEBU (protocole AES3) est une entreacutee eacutequilibreacutee isoleacutee eacutelectriquement agrave laide dun transformateur Elle permet demployer deux canaux audio dans un seul cacircble bipolaire blindeacute Les caracteacuteristiques du cacircble doivent ecirctre de 3 pocircles impeacutedance 100ohm torsadeacute et blindeacute avec connecteur XLR (AES3 standard)
RJ 45
|1|2|3|4|5|6|7|8|
RDnet
Chaque port RDNet des Control 2 et Control 8 peut ecirctre brancheacute agrave un maximum de 32 dispositifs compatibles placeacutes en cascade Dans lexemple suivant le port de luniteacute de controcircle RDNET CONTROL 2 est relieacute agrave lentreacutee DATA INPUT dun AC26N dont la sortie parallegravele DATA LINK est envoyeacutee agrave lentreacutee de lAC26N successif Dans lexemple [n] est un nombre compris entre 3 et 32 (limite maximale des dispositifs que lon peut relier agrave un sous-reacuteseau)
La longueur totale du cacircble CAT5 dun sous-reacuteseau NE peut PAS deacutepasser 900 megravetres
Le connecteur doit ecirctre relieacute comme 1 ndash disponible pour dautres fonctions (par exemple audio +) 2 ndash disponible pour dautres fonctions (par exemple audio )3 ndash disponible pour dautres fonctions (par exemple masse analogique)4 ndash masse numeacuterique5 ndash masse numeacuterique6 ndash disponible pour dautres fonctions (par exemple alimentation)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
MISE EN MARCHE
Lors de la mise en marche du dispositif linitialisation deacutebute et dure quelques secondes Leacutecran affiche le modegravele le logo et la barre de progression du chargement du programme
En fin de processus dinstallation leacutecran affiche la fenecirctre du menu Meters Pour connaicirctre les indications en deacutetail consulter le paragraphe DESCRIPTION FENETRE MENU Meters
LAC26N est precirct agrave lemploi
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION ET VISUALISATION
Pour entrer dans la fenecirctre du menu principal il faut pousser sur la touche MENU ( ) agrave lavant du dispositifDune page quelconque du menu en poussant sur la touche ESCrdquo ( ) on revient automatiquement sur la page-eacutecran preacuteceacutedente
MENU PRINCIPAL
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Le processeur contient six menus Ils montrent etou configurent les paramegravetres du systegravemeLes menus principaux sont
Meters Visualisation des niveaux des entreacutees et des sorties visualisation du programme utiliseacute et eacutetat mute rapide
Preset Meacutemoriser enregistrer et eacuteliminer les configurations du systegraveme
Matrix seacutelectionner les sorties en fonction du signal entrant
Ch Job configuration de chaque signal
X-Over configurer les freacutequences de coupure et les types de filtres pour chaque sortie
Option attribution des entreacutees et des sorties contraste daffichage la version du micrologiciel les entreacutees et dautres options
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
47
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
48
DESCRIPTION DE LA FENETRE MENU Metersrdquo
Cette fenecirctre permet de visualiser les configurations et leacutetat geacuteneacuteral des entreacutees et des sorties la version du programme utiliseacute son eacutetat et le mode de pilotage du systegraveme
Les menus et les options afficheacutees peuvent se seacutelectionner en tournant la manette ldquoFUNCTIONS SETECTORrdquo ( ) Pour avoir accegraves agrave linteacuterieur de la seacutelection il faut mettre le paramegravetre souhaiteacute en eacutevidence et pousser sur la manette ldquoPush Enterrdquo ( | ) Il faut en faire de mecircme pour seacutelectionner etou modifier les options dans les commandes du menu
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositifAvec des signaux dentreacutee numeacuteriques les indications ldquoArdquo et ldquoBrdquo correspondent agrave lentreacuteeEn tournant la manette ldquoFUNCTIONS SELECTORrdquo [2] on fait deacutefiler en mode cyclique les canaux dentreacutee de sortie et lindication de mute geacuteneacuteral (d) le canal seacutelectionneacute est mis en eacutevidence
b) BARRE DE NIVEAU DE COMPRESSIONMUTE CANAL
COMPRESSION DE SIGNALLa compression du signal est visualiseacutee par le deacutefilement de la barre de droite de haut en bas
MUTE Chaque canal peut ecirctre placeacute en mute Seacutelectionner le canal et pousser sur la manette ldquoPush Enterrdquo [2] pour valider le changement deacutetat Lindication du canal sera remplaceacutee par la lettre M et la barre sera totalement mise en eacutevidencePour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterations
c) BARRE DE NIVEAU DE SIGNALLindication du niveau de chaque canal est signaleacutee par le deacutefilement de la barre de gauche
d) MUTE GENERALIl est possible de mettre simultaneacutement toutes les entreacutees et les sorties en mute Tourner la manette ldquoFUNCTIONS SELECTORrdquo seacutelectionner la lettre M et pousser sur la manette Push EnterPour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterationsLe mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) MODES DE COMMANDEIl affiche le mode dutilisation etou les dispositifs qui sont relieacutes agrave lAC26N
Local = utilisation autonome Aucune connexion agrave un dispositif exteacuterieur
NET = relieacute directement au reacuteseau deacutedieacute RDNet et agrave lordinateur
USB = relieacute directement agrave un ordinateur par cacircble USB
f) INDICATION DETAT DE PARAMETRAGECette indication permet de constater si un ou plusieurs paramegravetre(s) du programme chargeacute aont eacuteteacute modifieacute(s) par rapport au dernier sauvetage
= programme dorigine
= programme avec des paramegravetres modifieacutes
g) PROGRAMME CONFIGURELe chiffre indique le programme chargeacute et utiliseacute par le systegraveme agrave lemplacement de sauvetage Consulter le menu de Preset pour de plus amples deacutetails
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
DESCRIPTION DE LA FENETRE MENU Ch Job
Cette fenecirctre permet dafficher la configuration de chaque canal
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) NIVEAU DU SIGNALIndique le gain du signal Laugmentation de lintensiteacute dun signal est libelleacutee en deacutecibel (dB) Le paramegravetre peut ecirctre seacutelectionneacute de -8000dB agrave +2000dB avec des pas de 001dB Une augmentation de 6dB est eacutegale approximativement au redoublement agrave leacutechelle lineacuteaire du niveau du signal sous tensionAvec un gain supeacuterieur agrave 0dB le signal est amplifieacute tandis quavec un gain infeacuterieur agrave 0dB le signal est atteacutenueacute
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
49
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
50
c) DELAI DU SIGNAL (DELAY)Le signal audio reproduit peut ecirctre retardeacute pour permettre lalignement acoustique Cela compense les diffeacuterentes positions des diffuseurs pendant linstallation et la reproduction sonore Il se libelle en mS Le paramegravetre peut ecirctre seacutelectionneacute de 00mS agrave 729mS avec un pas de 01mSPour aligner un signal audio il est possible dutiliser la formule suivante
Deacutelai = (GAPx1000)344
Deacutelai = ms (en millisecondes)GAP = distance du diffuseur du point de reacutefeacuterence (en megravetres)Vitesse du son = 344ms
d) MUTEChaque canal peut ecirctre placeacute en mute La mecircme commande peut ecirctre activeacutee dans la fenecirctre du menu meters NB Le mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) PhasePermet la rotation de phase de 180deg par rapport au signal entrantCette rotation permet loptimisation surtout des basses freacutequences dans les installations complexes
f) EGALISATIONCette commande ouvre la fenecirctre du menu deacutegalisation de chaque canal Elle sert surtout pour corriger une ou plusieurs freacutequences qui doivent ecirctre atteacutenueacutees ou augmenteacutees
M M
LAC26N gegravere 12 filtres par canal dentreacutee et sortie avec trois types de configurations diffeacuterentes - Leacutegaliseur PEQ (peaking equalizer) est ideacuteal pour identifier isoler et
corriger une seule plage de freacutequences bien deacutetermineacutee Toutes les freacutequences passent mais il augmente ou diminue uniquement celles autour de la freacutequence centrale pour une bande preacutecise et un gain deacutefini
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessus de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessous de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
f Numeacuterotation des 12 filtres disponibles pour cette entreacutee ou cette sortie1
f Le type de filtre est afficheacute 2
Dis Deacutesactiveacute (absent)
PEQ Peaking equlizer
Sh H Filtre high-shelf
Sh L Filtre high-shelf
Exemples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
REMARQUELe paramegravetre Bw deacutetermine le champ de freacutequences adjacent agrave la freacutequence configureacutee ougrave est activeacute le filtre Plus la valeur Bw est eacuteleveacutee plus vaste est le champ de freacutequences (1Bw=1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONCette commande ouvre la fenecirctre du menu de compression de chaque canal
g1) TresholdIdentifie le seuil ougrave commence le rapport de compression La valeur de base 11
g2) RatioIndique le rapport de conversion entre le signal entrant et le signal sortant
g3) Post Gain Attach Release HoldCes donneacutees deacutependent du rapport de conversion que lon veut obtenir - Post Gain est le gain de sortie- Attack est le temps dattaque - Release est le temps de relacircchement- Hold est le temps de maintien
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
52
DESCRIPTION DE LA FENETRE MENU Preset
Cette fenecirctre permet de meacutemoriser jusquagrave 32 configurations dans lAC26NLe fabricant fournit le systegraveme avec un programme configureacute et enregistreacute en position 0 et non susceptible deacutecrasement
032 Elle indique lemplacement de sauvetage de la configurationCe numeacutero apparaicirct dans la fenecirctre Meters en position (g) A tout moment le programme utiliseacute peut ecirctre afficheacute par lutilisateur
Empty Preset Cest le nom qui est associeacute au numeacutero de lemplacement quand aucune configuration (vide) nest enregistreacutee
Local preset Local preset est le nom qui est associeacute au numeacutero de lemplacement quand on enregistre une configuration NB = Il est possible denregistrer une configuration avec lenom souhaiteacute de 16 lettres tout au plus agrave condition que lonutilise linterface via lordinateur
Le nom du programme assigneacute est indiqueacutePour toucher agrave lapplication 3 choix soffrent agrave vous
Save Le programme est enregistreacute en meacutemoire de lAC26N
Del Le programme est effaceacute
Load Le programme est chargeacute et precirct agrave lemploi
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
51
DESCRIPTION DE LA FENETRE MENU X-Over
Cette fenecirctre permet de seacutelectionner un filtre passe bas un filtre passe haut ou par la combinaison des deux de creacuteer un filtre passe bande pour chaque sortieLe filtre actif est un Linkwitz-Riley qui permet de seacutelectionner la pente de 12dBoct 24dBoct ou 48dBoct et sa freacutequence de coupure
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) CANAUX DE SORTIE
Les connecteurs de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) FILTRE CROSSOVERSeacutelectionner le filtre selon les besoins Il est possible de seacutelectionner
Dis Aucun filtre activeacute
HP Filtre passe-haut laisse passer uniquement la partie de signal audio supeacuterieure agrave la freacutequence de coupure
LP Filtre passe-bas laisse passer uniquement la partie de signal audio infeacuterieure agrave la freacutequence de coupure
Configuration du filtre Passe-haut Passe-bas
Rien Dis Dis
Passe-haut HP Dis
Passe-bas Dis LP
Passe-bande HP LP
12dBoct
24dBoct
Hz
dB
Ga
in 48dBoct
12dBoct
24dBoct
Hz
dB
Ga
in
48dBoct
c) PENTE DATTENUATIONSeacutelectionner la pente datteacutenuation du signal audio en fonction de la diminution que lon veut obtenir Plus la pente datteacutenuation est eacuteleveacutee agrave eacutegaliteacute de freacutequence de coupure plus eacuteleveacutee sera la seacutelection du signal Il est possible de seacutelectionner
12 correspond agrave 12dboct
24 correspond agrave 24dboct
48 correspond agrave 48dboct
d) FREQUENCE DE COUPUREElle permet de reacutegler la freacutequence de passage des freacutequences infeacuterieures (filtre passe-bas) ou des freacutequences supeacuterieures (filtre passe-haut) uniquementLe choix de la coupure deacutepend de la reproduction que lon veut obtenirLuniteacute de mesure utiliseacutee est lHz
Hz
Hz
dB
dB
Ga
in
f0
f0
0dB0dB
0dB
-6dB
freacutequence
freacutequence
freacutequence
freacutequence
Ga
in
f0
0dB
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
53
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
54
DESCRIPTION DE LA FENETRE MENU Matrix
Elle permet de seacutelectionner le signal entrant agrave utiliser comme source pour chaque sortie
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) CANAUX DE SORTIEIdentification du canal sortant agrave reacutegler
b) IDENTIFICATIONS DES ENTREESSeacutelectionner le type de signal agrave associer agrave chaque sortie en fonction des besoins Il est possible de seacutelectionner
In A Le signal entrant A est associeacute
In B Le signal entrant B est associeacute
In A+B La somme algeacutebrique des deux signaux entrants A et B est associeacutee
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
DESCRIPTION DE LA FENETRE MENU Option
Permet dafficher les reacuteglages du systegraveme comme lassignation des entreacutees et des sorties latteacutenuation le contraste de laffichage et la version du logiciel
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcCette option permet de reacutegler le type de signal audio entrant
An In =signaux audio analogiques (entreacutees ldquoArdquo et ldquoBrdquo)
Dig In =signaux audio numeacuteriques (entreacutee AESEBU)
DigOut SrcCette option permet de seacutelectionner la source audio qui sera adresseacutee sur le connecteur AESEBU OUT (sortie numeacuterique)
An In = signaux audio des entreacutees analogiques
Dig In =signaux audio sur lentreacutee numeacuterique
OUT 1-2 = signaux audio sur les sorties 1 et 2
OUT 3-4 = signaux audio sur les sorties 3 et 4
OUT 5-6 = signaux audio sur les sorties 5 et 6
Input ModePermet de configurer les entreacutees
Indip = sont indeacutependantes et autonomes Ne sont soumises agrave aucun type de lien
Linked = sont unies et fonctionnent en mode steacutereacuteo Les compresseurs les filtres les deacutelais le volume sont identiques pour les deux canaux
Atten PadIndique le mode de reacuteglage du seacutelecteur ldquo-6dBrdquo placeacute agrave larriegravere [reacutef 5] Il faut activer ce seacutelecteur quand les niveaux dentreacutee analogiques sont trop eacuteleveacutes Le seacutelecteur sactive uniquement par le bouton Dans le menu il sagit dune simple visualisation
0dB = seacutelecteur non activeacute Les signaux dentreacutee sont identiques agrave la source entrante
-6dB = seacutelecteur activeacute Les signaux entrants sont atteacutenueacutes de -6dB par le processeur interne
ContrastIl permet de reacutegler le contraste de laffichage agrave cristaux liquides pour compenser la diffeacuterence de luminositeacute avec le lieu dinstallation Une plus grande clarteacute de laffichage permet de naviguer convenablement et rapidement dans les menusLe reacuteglage agrave la sortie de lusine du fabricant est de 60
10 plus clair 60 plus fonceacute 100
Fw VersIndique la version du logiciel du processeur
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
55
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
56
DONNES TECHINIQUES
PERFORMANCES AUDIOReacuteponse en freacutequence +- 01dB (20 to 30kHz)Plage dynamique 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsion 0002 (1kHz +4dBu)
PERFORMANCES AUDIO NUMERIQUES Processeur DSP 2856-bit Freacutequence de traitement des donneacutees 48KHzConvertisseurs analogiques 24-bit BURR BROWNDeacutelai de propagation 15msMeacutemorisations des configurations 32 preset
CONTROLES Affichage LCD graficoBoutonsCommandes ESC - MENU - FUNCTIONS SELECTION
ENTERENTREESSORTIESEntreacutee analogique ndeg2 x XLR (3 broches femelle)
Impeacutedance dentreacutee gt10KOhmNiveau maximum +21dBu senza PAD
+27dBu con PADSortie analogique ndeg6 x XLR (3 broches macircle )
Impeacutedance de sortie 50OhmNiveau maximum +21dBuType Balanceacute
Entreacutee numeacuterique ndeg1x XLR (3 broches femelle)Type SPDIF-AESEBU (AES3)
Sortie numeacuterique ndeg1x XLR (3 broches macircle )Type conforme agrave la norme de lentreacutee
EntreacuteesSortie Rdnet ndeg2 x XLR RJ45 (cacircble CAT 5)USB Type B
PARAMETRES DE CONTROLE DU SONGain -80dB a +20dB eacutetape 01dBDeacutelai Entreacutee 0 a 729mS eacutetape 01 mS
Sortie 0 a 340mS eacutetape 01mSRotation de phase 0deg - 180deg
COMPRESSIONSeuil -80dB a +20dB eacutetape 01dBRapport 11 a Inf1 eacutetape 001Gain agrave la sortie 0dB a 40dB eacutetape 01dBTemps dattaque 1mS a 1000mS eacutetape 01mSTemps de relacircchement 1mS a 1000mS eacutetape 01mSTemps de maintien 1mS a 1000mS eacutetape 01mS
EGALISEURS12 eacutegaliseurs pour chaque entreacutee et sortieType PEQ (parameacutetrique) Hi-shelf Lo-sheft
Freacutequence 20Hz a 20KHz eacutetape 1HzGain -30dB a +15dB eacutetape 001dBBande 005dB a 2dB eacutetape 001dB (uniquement pour PEQ)
FILTRES CROSSOVERFiltre Linkwitz Riley
Type HF high-shelfLF low-shelf
Pente 12dBoct - 24dBoct - 48dBoctFreacutequence de coupure 5Hz a 20KHz eacutetape 1Hz
ALIMENTATION Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)POIDS 19Kg
Remarques Speacutecifications sujettes agrave modifications sans preacuteavis
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
2 VIE ATTIVO2 WAY ACTIVE
3 VIE PASSIVO3 WAY PASSIVE
L
L
A
A
HIGH L
MID L
LOW HIGHMID RHIGHMID L
LOW L
HIGH R
MID R
LOW R
R
R
B
B
1
1
2
2
3
3
456
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
Menu Matrix configurationMatrix
57 58
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
EROUIG ATRIX TNM
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
OU
TP
UT
1
OU
TP
UT
2
OU
TP
UT
3
OU
TP
UT
4
OU
TP
UT
5
OU
TP
UT
6
AE
S-E
BU
OU
TP
UT
INP
UT
A
AE
S-E
BU
INP
UT
INP
UT
B
D D D D D D
D D
A A A A A A
A SA
MP
LE
RA
TE
CO
NV
A
LIN
KA
BL
E
SC
HE
MA
A B
LO
CC
HI -
BL
OC
K D
IAG
RA
MB
LO
CK
SC
HA
LT
BIL
D -
SC
HE
MA
S F
ON
CT
ION
NE
LS
LINE ARRAY SUB MONO ATTIVO
LINE ARRAY SUB MONO ACTIVEINGRESSI - INPUT
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
L
L
L
A
A
A
AESEBU IN
AESEBU IN
AESEBU IN
AESEBU OUT
AESEBU IN
AESEBU IN
AESEBU OUT
R
R
R
LR
B
B
B
123456
HIGHMID L
HIGHMID L HIGHMID R
HIGHMID R
LOW L LOW R
LAYER
DISPLAY MEMORY
FADER MODE
LAYER
DISPLAY MEMORY
FADER MODE
Ingresso ANALOGICO
ANALOG Input
Collegamento in cascata
Link connections
Ingresso DIGITALE
DIGITAL inputA B
BALANCED AUDIO INPUTS
-6dB
PUSH PUSH
IN OUT
AES EBUPUSH
Oppure
or
Oppure
or
Menu Option configurationOption
Menu Option configurationOption Menu Option configurationOption
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type Analog
AES out An In
Input type Analog
AES out An In
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
59 60
InA-B Src Dig InInA-B Src Dig InInA-B Src An InInA-B Src An In
frequenzaHz
dB
Gu
ad
ag
no
60 200 2800
0dB0dB
-6dB
Esempio di un sistema a 3-vie
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
Out 1 Out 2 Out 3
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Esempio di un sistema a 3-vie
61 62
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
26NAC 26NAC
R TE
DO
R
MO LEU O R CE S
E O TR L A
S O
O C ND I P
P hsuernE t
o su cti nF nel rS e tc o
E CSME UN
IGCHTE OL SN EOBd
ocaL l
M
0
484
467
430
44
31
75
12
7
DIMENSIONI DIMENSIONSABMESSUNGEN DIMENSIONS
INTRODUCTIONAC26N est un processeur audio numeacuterique pour la gestion de leacutequipement audio conccedilu pour des installations fixes et mobiles Il fonctionne selon une technologie de pointe avec des processeurs agrave 2856bits et des convertisseurs ADDA agrave 24-bits hautes performances Les fonctions du processeur sont les niveaux dentreacutee et de sortie le deacutelai (delay) la polariteacute 12 bandes deacutegalisation par canal dentreacutee et de sortie diffeacuterentes seacutelections de croisement (crossover) et un limiteur hautes performances Le controcircle des filtres a une reacutesolution de 1Hz Les entreacutees et les sorties peuvent ecirctre programmeacutees en plusieurs configurations pour satisfaire tous les besoins AC26N peut ecirctre controcircleacute en temps reacuteel et tous les paramegravetres peuvent ecirctre configureacutes depuis le pupitre frontale et par ordinateur avec interface graphique intuitive accessible via le logiciel laquoDVA Networkraquo et une connexion de reacuteseau deacutedieacutee RDnet ou USBLa mise agrave jour du logiciel pour lUniteacute centrale et DSP par ordinateur portable permet de maintenir le dispositif actualiseacute Il est possible denregistrer et de rappeler 32 configurations preacute-eacutequipeacutees de configuration
Contenu de lemballage - AC26N - Mode demploi- CD logiciel- Cacircble dalimentation
Caracteacuteristiques- 2 entreacutees et 6 sorties avec adressage flexible- Entreacutee et sortie steacutereacuteo AESEBU adressables - DSP 2856-bit- Convertisseurs AD BURR BWOWN 24-bit hautes performances- Freacutequence de reacutesolution des filtres 1 Hz - 12 eacutegaliseurs parameacutetriques pour chaque entreacutee et sortie- 2 filtres de croisement par sortie avec pente seacutelectionnable agrave 122448dBoct- DRC agrave configuration multiple hautes performances pour configuration limiteur
compression pour chaque entreacutee et sortie- Niveau reacuteglable en dB polariteacute et deacutelai pour chaque entreacutee et sortie- Mise agrave jour du micrologiciel par lordinateur- Affichage graphique agrave cristaux liquides- 32 preacutereacuteglages enregistrables par lutilisateur- Interface USB pour le controcircle et la configuration par ordinateur- Interface RDnet permettant de controcircler jusquagrave 256 dispositifs agrave distance
PC
PC
RDNETcontrol(RDNET Control2RDNET Control8)
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
FONCTIONS DE LA FACE AVANT
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
1 2 3 4
COMMANDES ET FONCTIONS1) AFFICHAGE
Laffichage graphique agrave cristaux liquides permet de visualiser et deacutediter les informations de lAC26N sans utiliser lordinateur Le contraste peut ecirctre configureacute dans le menu principal
2) MANETTE Functions Selector et Push EnterCe controcircle permet de se deacuteplacer de seacutelectionner et de modifier les paramegravetres dans les menus affichables agrave leacutecranRotation de la manette (Functions Selectors)- permet de se deacuteplacer sur les diffeacuterentes pages du menu - permet de modifier les paramegravetres seacutelectionneacutesPression de la manette (Push Enter)- permet de seacutelectionnervalider les paramegravetres
3) Bouton ESC Ce controcircle permet de quitter les menus afficheacutes ou de revenir agrave la visualisation preacuteceacutedente
4) Bouton Menu Ce controcircle permet dacceacuteder directement au menu principal
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESCMENU
TECHNOLOGIESBd
Local
M
0
Fra
nccedilais
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
43
Cara
cte
risti
qu
es t
ech
niq
ues
Cara
cte
risti
qu
es t
ech
niq
ues
Fra
nccedilais
44
DVA Network
AC26N est eacutequipeacute dune interface de reacuteseau proprieacutetaire deacutenommeacutee RDNET au moyen de laquelle il est possible de sinterfacer agrave lordinateur agrave travers un peacuteripheacuterique (RDNET control)
Pour cela un protocole de communication a eacuteteacute deacuteveloppeacute avec lequel il est possible de recevoir et denvoyer les donneacutees ce branchement permet de faire le monitorage en temps reacuteel des paramegravetres du diffuseur comme puissance de sortie tempeacuterature de lamplificateur eacutetat du limiteur etc Il est aussi possible de seacutelectionner diffeacuterentes eacutegalisations ou den creacuteer de nouvelles et de reacutegler les niveaux de volume souhaiteacutes au moyen dun plug-in approprieacute
On conseille de teacuteleacutecharger gratuitement le logiciel DVA Network directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
DVA USB Manager
On conseille de teacuteleacutecharger gratuitement le logiciel DVA USB Manager directement agrave partir du site dB Technologies (wwwdbtechnologiescom) dans la section deacutedieacutee laquo Software amp Controller raquo
Le micrologiciel du module amplificateur peut ecirctre remis agrave jour par le port USBPour rendre cette mise agrave jour possible et facile un programme speacutecifique a eacuteteacute deacuteveloppeacute
DOWNLOAD
DOWNLOAD
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
CONNEXIONS DU PANNEAU ARRIEgraveRE
1586 75 141210 11 13 169 17
14) Connecteur ldquo USBrdquoCe connecteur USB (type B) permet de connecter le processeur agrave un ordinateur pour le controcircle et la mise agrave jour du micrologiciel via un programme deacutedieacute (DVA Network)
15) PRISE DALIMENTATION MAINSPermet la connexion du cacircble dalimentation fourni de seacuterie
16) PORTE-FUSIBLE FUSELogement pour fusible de ligne
17) INTERRUPTEUR GENERAL POWERLinterrupteur permet de mettre en marche ou deacuteteindre le controcircleur audio
COMMANDES ET FONCTIONS
5) SELECTEUR ldquo-6dBrdquoLe seacutelecteur permet de reacuteduire de 6dB les niveaux dentreacutee analogiques XLR [6] tout en compensant les niveaux eacuteleveacutes de sortie des meacutelangeurs ou dautres dispositifs audio Quand la barre du niveau de signal des entreacutees sur laffichage [1] reste au maximum cela indique que le niveau du signal entrant est eacuteleveacute Il est alors conseilleacute dutiliser latteacutenuation -6dBIl est possible de veacuterifier quand le seacutelecteur est activeacute par le menu Option
6) CONNECTEURS DENTREE ldquoArdquo ET ldquoBrdquoEntreacutees eacutequilibreacutees au niveau de la ligneIls sont en mesure daccepter des connecteurs XLR macircles
7) CONNECTEURS DE SORTIE ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo ET ldquo6rdquoSorties eacutequilibreacutees au niveau de la ligne Ils sont en mesure daccepter des connecteurs XLR femelles
Prendre garde agrave brancher convenablement les sorties sur les diffuseurs ou les amplificateurs en fonction des configurations de chaque canal pour eacuteviter des deacutegacircts et des problegravemes de fonctionnement
Section ldquoAESEBUrdquo
8) CONNECTEUR DENTREE INOutre les entreacutees audio analogiques une entreacutee audio numeacuterique SPDIF-AESEBU (AES3) a eacuteteacute preacutevue et peut ecirctre seacutelectionneacutee par le menu de setupLentreacutee requiert une connexion eacutequilibreacutee en utilisant un connecteur XLR avec un cacircble agrave 3 conducteurs de 110ohm torsadeacute
9) CONNECTEUR DE SORTIE OUTCe connecteur permet de relancer le signal audio dans les entreacutees analogiques ou numeacuteriques ou sur les sorties La source doit ecirctre reacutegleacutee par le menu OptionLa connexion sera conforme agrave la mecircme norme que lentreacutee [reacutef8]
Section ldquoRDNETrdquo
10) CONNECTEUR DENTREE DATA INPUTConnecteur RJ45 entreacutee de donneacutees
11) CONNECTEUR DE SORTIE DATA LINKConnecteur RJ45 sortie de donneacutees pour la connexion de seacuterie en cascade
12) VOYANT LUMINEUX ONCe voyant de couleur verte sallume uniquement quand lAC26N a reconnu et est connecteacute agrave luniteacute principale RDNET par lordinateur
13) VOYANT LUMINEUX ACTIVECe voyant de couleur jaune clignote quand une transmission des donneacutees est active entre RDNET et le dispositif
PUSH
P SHU
SHPU
P SHU
PUSH
CONNEXIONS
Audio analogiquesLes connexions eacutequilibreacutees permettent de reacuteduire au minimum le bruit provoqueacute par les cacircbles et dutiliser de longs cacircblesCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLe connecteur XLR doit ecirctre brancheacute avec la broche 1 agrave la masse la broche 2 au chaud (+) et la broche 3 au froid (-) En cas de cacircble blindeacute brancher le blindage agrave la broche 1Les cacircbles de connexion XLR-XLR et XLR-Jack14(63mm) peuvent semployer pour la connexion agrave lAC26N
12
3
Entreacutee
Entreacutee
XLR - femme
XLR - femme
1 2
3
Sortie
Sortie
XLR - Macircle
XLR - Macircle
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2 = Point chaudPhase +VE
Broche 3 =Point froidPhase -VE
Broche 3 =Point froidPhase -VE
Anneau
Manchon
Pointe Point chaudPhase +VE
Anneau = Point froidPhase -VE
ManchonB Masselindeacute
Pointe
Les connexions deacuteseacutequilibreacutees peuvent semployer mecircme si le bruit provoqueacute par les cacircbles augmente Les cacircbles ne peuvent deacutepasser 5m de longCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLes connexions deacuteseacutequilibreacutees peuvent abaisser le niveau du signal entrant de 6dB Pour remeacutedier agrave cet inconveacutenient il faut brancher la broche 3 agrave la masse mecircme si cela augmente le bruit
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
45
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
46
12
3
1 2
3
Pointe Manchon
Pointe = Signal
Broche 3 = Link to Pin 1
Broche 3 = Link to Pin 1
ManchonB Masselindeacute
Audio numeacuteriques (AESEBU)
AESEBU (protocole AES3) est une entreacutee eacutequilibreacutee isoleacutee eacutelectriquement agrave laide dun transformateur Elle permet demployer deux canaux audio dans un seul cacircble bipolaire blindeacute Les caracteacuteristiques du cacircble doivent ecirctre de 3 pocircles impeacutedance 100ohm torsadeacute et blindeacute avec connecteur XLR (AES3 standard)
RJ 45
|1|2|3|4|5|6|7|8|
RDnet
Chaque port RDNet des Control 2 et Control 8 peut ecirctre brancheacute agrave un maximum de 32 dispositifs compatibles placeacutes en cascade Dans lexemple suivant le port de luniteacute de controcircle RDNET CONTROL 2 est relieacute agrave lentreacutee DATA INPUT dun AC26N dont la sortie parallegravele DATA LINK est envoyeacutee agrave lentreacutee de lAC26N successif Dans lexemple [n] est un nombre compris entre 3 et 32 (limite maximale des dispositifs que lon peut relier agrave un sous-reacuteseau)
La longueur totale du cacircble CAT5 dun sous-reacuteseau NE peut PAS deacutepasser 900 megravetres
Le connecteur doit ecirctre relieacute comme 1 ndash disponible pour dautres fonctions (par exemple audio +) 2 ndash disponible pour dautres fonctions (par exemple audio )3 ndash disponible pour dautres fonctions (par exemple masse analogique)4 ndash masse numeacuterique5 ndash masse numeacuterique6 ndash disponible pour dautres fonctions (par exemple alimentation)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
MISE EN MARCHE
Lors de la mise en marche du dispositif linitialisation deacutebute et dure quelques secondes Leacutecran affiche le modegravele le logo et la barre de progression du chargement du programme
En fin de processus dinstallation leacutecran affiche la fenecirctre du menu Meters Pour connaicirctre les indications en deacutetail consulter le paragraphe DESCRIPTION FENETRE MENU Meters
LAC26N est precirct agrave lemploi
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION ET VISUALISATION
Pour entrer dans la fenecirctre du menu principal il faut pousser sur la touche MENU ( ) agrave lavant du dispositifDune page quelconque du menu en poussant sur la touche ESCrdquo ( ) on revient automatiquement sur la page-eacutecran preacuteceacutedente
MENU PRINCIPAL
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Le processeur contient six menus Ils montrent etou configurent les paramegravetres du systegravemeLes menus principaux sont
Meters Visualisation des niveaux des entreacutees et des sorties visualisation du programme utiliseacute et eacutetat mute rapide
Preset Meacutemoriser enregistrer et eacuteliminer les configurations du systegraveme
Matrix seacutelectionner les sorties en fonction du signal entrant
Ch Job configuration de chaque signal
X-Over configurer les freacutequences de coupure et les types de filtres pour chaque sortie
Option attribution des entreacutees et des sorties contraste daffichage la version du micrologiciel les entreacutees et dautres options
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
47
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
48
DESCRIPTION DE LA FENETRE MENU Metersrdquo
Cette fenecirctre permet de visualiser les configurations et leacutetat geacuteneacuteral des entreacutees et des sorties la version du programme utiliseacute son eacutetat et le mode de pilotage du systegraveme
Les menus et les options afficheacutees peuvent se seacutelectionner en tournant la manette ldquoFUNCTIONS SETECTORrdquo ( ) Pour avoir accegraves agrave linteacuterieur de la seacutelection il faut mettre le paramegravetre souhaiteacute en eacutevidence et pousser sur la manette ldquoPush Enterrdquo ( | ) Il faut en faire de mecircme pour seacutelectionner etou modifier les options dans les commandes du menu
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositifAvec des signaux dentreacutee numeacuteriques les indications ldquoArdquo et ldquoBrdquo correspondent agrave lentreacuteeEn tournant la manette ldquoFUNCTIONS SELECTORrdquo [2] on fait deacutefiler en mode cyclique les canaux dentreacutee de sortie et lindication de mute geacuteneacuteral (d) le canal seacutelectionneacute est mis en eacutevidence
b) BARRE DE NIVEAU DE COMPRESSIONMUTE CANAL
COMPRESSION DE SIGNALLa compression du signal est visualiseacutee par le deacutefilement de la barre de droite de haut en bas
MUTE Chaque canal peut ecirctre placeacute en mute Seacutelectionner le canal et pousser sur la manette ldquoPush Enterrdquo [2] pour valider le changement deacutetat Lindication du canal sera remplaceacutee par la lettre M et la barre sera totalement mise en eacutevidencePour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterations
c) BARRE DE NIVEAU DE SIGNALLindication du niveau de chaque canal est signaleacutee par le deacutefilement de la barre de gauche
d) MUTE GENERALIl est possible de mettre simultaneacutement toutes les entreacutees et les sorties en mute Tourner la manette ldquoFUNCTIONS SELECTORrdquo seacutelectionner la lettre M et pousser sur la manette Push EnterPour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterationsLe mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) MODES DE COMMANDEIl affiche le mode dutilisation etou les dispositifs qui sont relieacutes agrave lAC26N
Local = utilisation autonome Aucune connexion agrave un dispositif exteacuterieur
NET = relieacute directement au reacuteseau deacutedieacute RDNet et agrave lordinateur
USB = relieacute directement agrave un ordinateur par cacircble USB
f) INDICATION DETAT DE PARAMETRAGECette indication permet de constater si un ou plusieurs paramegravetre(s) du programme chargeacute aont eacuteteacute modifieacute(s) par rapport au dernier sauvetage
= programme dorigine
= programme avec des paramegravetres modifieacutes
g) PROGRAMME CONFIGURELe chiffre indique le programme chargeacute et utiliseacute par le systegraveme agrave lemplacement de sauvetage Consulter le menu de Preset pour de plus amples deacutetails
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
DESCRIPTION DE LA FENETRE MENU Ch Job
Cette fenecirctre permet dafficher la configuration de chaque canal
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) NIVEAU DU SIGNALIndique le gain du signal Laugmentation de lintensiteacute dun signal est libelleacutee en deacutecibel (dB) Le paramegravetre peut ecirctre seacutelectionneacute de -8000dB agrave +2000dB avec des pas de 001dB Une augmentation de 6dB est eacutegale approximativement au redoublement agrave leacutechelle lineacuteaire du niveau du signal sous tensionAvec un gain supeacuterieur agrave 0dB le signal est amplifieacute tandis quavec un gain infeacuterieur agrave 0dB le signal est atteacutenueacute
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
49
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
50
c) DELAI DU SIGNAL (DELAY)Le signal audio reproduit peut ecirctre retardeacute pour permettre lalignement acoustique Cela compense les diffeacuterentes positions des diffuseurs pendant linstallation et la reproduction sonore Il se libelle en mS Le paramegravetre peut ecirctre seacutelectionneacute de 00mS agrave 729mS avec un pas de 01mSPour aligner un signal audio il est possible dutiliser la formule suivante
Deacutelai = (GAPx1000)344
Deacutelai = ms (en millisecondes)GAP = distance du diffuseur du point de reacutefeacuterence (en megravetres)Vitesse du son = 344ms
d) MUTEChaque canal peut ecirctre placeacute en mute La mecircme commande peut ecirctre activeacutee dans la fenecirctre du menu meters NB Le mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) PhasePermet la rotation de phase de 180deg par rapport au signal entrantCette rotation permet loptimisation surtout des basses freacutequences dans les installations complexes
f) EGALISATIONCette commande ouvre la fenecirctre du menu deacutegalisation de chaque canal Elle sert surtout pour corriger une ou plusieurs freacutequences qui doivent ecirctre atteacutenueacutees ou augmenteacutees
M M
LAC26N gegravere 12 filtres par canal dentreacutee et sortie avec trois types de configurations diffeacuterentes - Leacutegaliseur PEQ (peaking equalizer) est ideacuteal pour identifier isoler et
corriger une seule plage de freacutequences bien deacutetermineacutee Toutes les freacutequences passent mais il augmente ou diminue uniquement celles autour de la freacutequence centrale pour une bande preacutecise et un gain deacutefini
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessus de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessous de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
f Numeacuterotation des 12 filtres disponibles pour cette entreacutee ou cette sortie1
f Le type de filtre est afficheacute 2
Dis Deacutesactiveacute (absent)
PEQ Peaking equlizer
Sh H Filtre high-shelf
Sh L Filtre high-shelf
Exemples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
REMARQUELe paramegravetre Bw deacutetermine le champ de freacutequences adjacent agrave la freacutequence configureacutee ougrave est activeacute le filtre Plus la valeur Bw est eacuteleveacutee plus vaste est le champ de freacutequences (1Bw=1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONCette commande ouvre la fenecirctre du menu de compression de chaque canal
g1) TresholdIdentifie le seuil ougrave commence le rapport de compression La valeur de base 11
g2) RatioIndique le rapport de conversion entre le signal entrant et le signal sortant
g3) Post Gain Attach Release HoldCes donneacutees deacutependent du rapport de conversion que lon veut obtenir - Post Gain est le gain de sortie- Attack est le temps dattaque - Release est le temps de relacircchement- Hold est le temps de maintien
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
52
DESCRIPTION DE LA FENETRE MENU Preset
Cette fenecirctre permet de meacutemoriser jusquagrave 32 configurations dans lAC26NLe fabricant fournit le systegraveme avec un programme configureacute et enregistreacute en position 0 et non susceptible deacutecrasement
032 Elle indique lemplacement de sauvetage de la configurationCe numeacutero apparaicirct dans la fenecirctre Meters en position (g) A tout moment le programme utiliseacute peut ecirctre afficheacute par lutilisateur
Empty Preset Cest le nom qui est associeacute au numeacutero de lemplacement quand aucune configuration (vide) nest enregistreacutee
Local preset Local preset est le nom qui est associeacute au numeacutero de lemplacement quand on enregistre une configuration NB = Il est possible denregistrer une configuration avec lenom souhaiteacute de 16 lettres tout au plus agrave condition que lonutilise linterface via lordinateur
Le nom du programme assigneacute est indiqueacutePour toucher agrave lapplication 3 choix soffrent agrave vous
Save Le programme est enregistreacute en meacutemoire de lAC26N
Del Le programme est effaceacute
Load Le programme est chargeacute et precirct agrave lemploi
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
51
DESCRIPTION DE LA FENETRE MENU X-Over
Cette fenecirctre permet de seacutelectionner un filtre passe bas un filtre passe haut ou par la combinaison des deux de creacuteer un filtre passe bande pour chaque sortieLe filtre actif est un Linkwitz-Riley qui permet de seacutelectionner la pente de 12dBoct 24dBoct ou 48dBoct et sa freacutequence de coupure
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) CANAUX DE SORTIE
Les connecteurs de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) FILTRE CROSSOVERSeacutelectionner le filtre selon les besoins Il est possible de seacutelectionner
Dis Aucun filtre activeacute
HP Filtre passe-haut laisse passer uniquement la partie de signal audio supeacuterieure agrave la freacutequence de coupure
LP Filtre passe-bas laisse passer uniquement la partie de signal audio infeacuterieure agrave la freacutequence de coupure
Configuration du filtre Passe-haut Passe-bas
Rien Dis Dis
Passe-haut HP Dis
Passe-bas Dis LP
Passe-bande HP LP
12dBoct
24dBoct
Hz
dB
Ga
in 48dBoct
12dBoct
24dBoct
Hz
dB
Ga
in
48dBoct
c) PENTE DATTENUATIONSeacutelectionner la pente datteacutenuation du signal audio en fonction de la diminution que lon veut obtenir Plus la pente datteacutenuation est eacuteleveacutee agrave eacutegaliteacute de freacutequence de coupure plus eacuteleveacutee sera la seacutelection du signal Il est possible de seacutelectionner
12 correspond agrave 12dboct
24 correspond agrave 24dboct
48 correspond agrave 48dboct
d) FREQUENCE DE COUPUREElle permet de reacutegler la freacutequence de passage des freacutequences infeacuterieures (filtre passe-bas) ou des freacutequences supeacuterieures (filtre passe-haut) uniquementLe choix de la coupure deacutepend de la reproduction que lon veut obtenirLuniteacute de mesure utiliseacutee est lHz
Hz
Hz
dB
dB
Ga
in
f0
f0
0dB0dB
0dB
-6dB
freacutequence
freacutequence
freacutequence
freacutequence
Ga
in
f0
0dB
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
53
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
54
DESCRIPTION DE LA FENETRE MENU Matrix
Elle permet de seacutelectionner le signal entrant agrave utiliser comme source pour chaque sortie
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) CANAUX DE SORTIEIdentification du canal sortant agrave reacutegler
b) IDENTIFICATIONS DES ENTREESSeacutelectionner le type de signal agrave associer agrave chaque sortie en fonction des besoins Il est possible de seacutelectionner
In A Le signal entrant A est associeacute
In B Le signal entrant B est associeacute
In A+B La somme algeacutebrique des deux signaux entrants A et B est associeacutee
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
DESCRIPTION DE LA FENETRE MENU Option
Permet dafficher les reacuteglages du systegraveme comme lassignation des entreacutees et des sorties latteacutenuation le contraste de laffichage et la version du logiciel
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcCette option permet de reacutegler le type de signal audio entrant
An In =signaux audio analogiques (entreacutees ldquoArdquo et ldquoBrdquo)
Dig In =signaux audio numeacuteriques (entreacutee AESEBU)
DigOut SrcCette option permet de seacutelectionner la source audio qui sera adresseacutee sur le connecteur AESEBU OUT (sortie numeacuterique)
An In = signaux audio des entreacutees analogiques
Dig In =signaux audio sur lentreacutee numeacuterique
OUT 1-2 = signaux audio sur les sorties 1 et 2
OUT 3-4 = signaux audio sur les sorties 3 et 4
OUT 5-6 = signaux audio sur les sorties 5 et 6
Input ModePermet de configurer les entreacutees
Indip = sont indeacutependantes et autonomes Ne sont soumises agrave aucun type de lien
Linked = sont unies et fonctionnent en mode steacutereacuteo Les compresseurs les filtres les deacutelais le volume sont identiques pour les deux canaux
Atten PadIndique le mode de reacuteglage du seacutelecteur ldquo-6dBrdquo placeacute agrave larriegravere [reacutef 5] Il faut activer ce seacutelecteur quand les niveaux dentreacutee analogiques sont trop eacuteleveacutes Le seacutelecteur sactive uniquement par le bouton Dans le menu il sagit dune simple visualisation
0dB = seacutelecteur non activeacute Les signaux dentreacutee sont identiques agrave la source entrante
-6dB = seacutelecteur activeacute Les signaux entrants sont atteacutenueacutes de -6dB par le processeur interne
ContrastIl permet de reacutegler le contraste de laffichage agrave cristaux liquides pour compenser la diffeacuterence de luminositeacute avec le lieu dinstallation Une plus grande clarteacute de laffichage permet de naviguer convenablement et rapidement dans les menusLe reacuteglage agrave la sortie de lusine du fabricant est de 60
10 plus clair 60 plus fonceacute 100
Fw VersIndique la version du logiciel du processeur
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
55
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
56
DONNES TECHINIQUES
PERFORMANCES AUDIOReacuteponse en freacutequence +- 01dB (20 to 30kHz)Plage dynamique 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsion 0002 (1kHz +4dBu)
PERFORMANCES AUDIO NUMERIQUES Processeur DSP 2856-bit Freacutequence de traitement des donneacutees 48KHzConvertisseurs analogiques 24-bit BURR BROWNDeacutelai de propagation 15msMeacutemorisations des configurations 32 preset
CONTROLES Affichage LCD graficoBoutonsCommandes ESC - MENU - FUNCTIONS SELECTION
ENTERENTREESSORTIESEntreacutee analogique ndeg2 x XLR (3 broches femelle)
Impeacutedance dentreacutee gt10KOhmNiveau maximum +21dBu senza PAD
+27dBu con PADSortie analogique ndeg6 x XLR (3 broches macircle )
Impeacutedance de sortie 50OhmNiveau maximum +21dBuType Balanceacute
Entreacutee numeacuterique ndeg1x XLR (3 broches femelle)Type SPDIF-AESEBU (AES3)
Sortie numeacuterique ndeg1x XLR (3 broches macircle )Type conforme agrave la norme de lentreacutee
EntreacuteesSortie Rdnet ndeg2 x XLR RJ45 (cacircble CAT 5)USB Type B
PARAMETRES DE CONTROLE DU SONGain -80dB a +20dB eacutetape 01dBDeacutelai Entreacutee 0 a 729mS eacutetape 01 mS
Sortie 0 a 340mS eacutetape 01mSRotation de phase 0deg - 180deg
COMPRESSIONSeuil -80dB a +20dB eacutetape 01dBRapport 11 a Inf1 eacutetape 001Gain agrave la sortie 0dB a 40dB eacutetape 01dBTemps dattaque 1mS a 1000mS eacutetape 01mSTemps de relacircchement 1mS a 1000mS eacutetape 01mSTemps de maintien 1mS a 1000mS eacutetape 01mS
EGALISEURS12 eacutegaliseurs pour chaque entreacutee et sortieType PEQ (parameacutetrique) Hi-shelf Lo-sheft
Freacutequence 20Hz a 20KHz eacutetape 1HzGain -30dB a +15dB eacutetape 001dBBande 005dB a 2dB eacutetape 001dB (uniquement pour PEQ)
FILTRES CROSSOVERFiltre Linkwitz Riley
Type HF high-shelfLF low-shelf
Pente 12dBoct - 24dBoct - 48dBoctFreacutequence de coupure 5Hz a 20KHz eacutetape 1Hz
ALIMENTATION Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)POIDS 19Kg
Remarques Speacutecifications sujettes agrave modifications sans preacuteavis
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
2 VIE ATTIVO2 WAY ACTIVE
3 VIE PASSIVO3 WAY PASSIVE
L
L
A
A
HIGH L
MID L
LOW HIGHMID RHIGHMID L
LOW L
HIGH R
MID R
LOW R
R
R
B
B
1
1
2
2
3
3
456
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
Menu Matrix configurationMatrix
57 58
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
EROUIG ATRIX TNM
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
OU
TP
UT
1
OU
TP
UT
2
OU
TP
UT
3
OU
TP
UT
4
OU
TP
UT
5
OU
TP
UT
6
AE
S-E
BU
OU
TP
UT
INP
UT
A
AE
S-E
BU
INP
UT
INP
UT
B
D D D D D D
D D
A A A A A A
A SA
MP
LE
RA
TE
CO
NV
A
LIN
KA
BL
E
SC
HE
MA
A B
LO
CC
HI -
BL
OC
K D
IAG
RA
MB
LO
CK
SC
HA
LT
BIL
D -
SC
HE
MA
S F
ON
CT
ION
NE
LS
LINE ARRAY SUB MONO ATTIVO
LINE ARRAY SUB MONO ACTIVEINGRESSI - INPUT
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
L
L
L
A
A
A
AESEBU IN
AESEBU IN
AESEBU IN
AESEBU OUT
AESEBU IN
AESEBU IN
AESEBU OUT
R
R
R
LR
B
B
B
123456
HIGHMID L
HIGHMID L HIGHMID R
HIGHMID R
LOW L LOW R
LAYER
DISPLAY MEMORY
FADER MODE
LAYER
DISPLAY MEMORY
FADER MODE
Ingresso ANALOGICO
ANALOG Input
Collegamento in cascata
Link connections
Ingresso DIGITALE
DIGITAL inputA B
BALANCED AUDIO INPUTS
-6dB
PUSH PUSH
IN OUT
AES EBUPUSH
Oppure
or
Oppure
or
Menu Option configurationOption
Menu Option configurationOption Menu Option configurationOption
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type Analog
AES out An In
Input type Analog
AES out An In
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
59 60
InA-B Src Dig InInA-B Src Dig InInA-B Src An InInA-B Src An In
frequenzaHz
dB
Gu
ad
ag
no
60 200 2800
0dB0dB
-6dB
Esempio di un sistema a 3-vie
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
Out 1 Out 2 Out 3
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Esempio di un sistema a 3-vie
61 62
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
26NAC 26NAC
R TE
DO
R
MO LEU O R CE S
E O TR L A
S O
O C ND I P
P hsuernE t
o su cti nF nel rS e tc o
E CSME UN
IGCHTE OL SN EOBd
ocaL l
M
0
484
467
430
44
31
75
12
7
DIMENSIONI DIMENSIONSABMESSUNGEN DIMENSIONS
L177007324DataLink
Made in Italy
REPLACE FUSE WITH SAME RATING
ldquoCAUTIONrdquoTO PREVENT ELECTRICAL SHOCK
DO NOT REMOVE COVERldquoAVISrdquo
RISQUE DE CHOCH ELECTRIQUENE PAS OUVRIR
MAINS FUSE POWER1 2 3 4 5 6A B
BALANCED AUDIO INPUTS BALANCED AUDIO OUTPUTS IN OUT ACTIVE
ON
DataInput
FULL RANGE 100-240V~ 50-60Hz05-025A max
FUSE T1A L 250V~
SERIAL N
Service Data
USB
AES EBU
-6dB
PUSH PUSHPUSH PUSHPUSH
00
II
27 0 70 3 4L 71
D atanL ki
Id ta lye ainM
IE
A FS T
CEAM
E
H
R P
G
LS
N
U E WI
TRA
ldquo OCAUTI NrdquoC
RR
K
VL
LC
EA S
T PE
O
E T T IC EH
ON
NOE O E
T E CD
VO R
RMO V
ldquo rdquoAV SI
E EE I
IS U H R D
C
RH
E
Q CL
UC EO
T Q
N P S IR U RA O E
V
I PO
M S U
AF
W
N SEER
12
34
56
AB
B AI
L C DI P S
AT
D O U
A N EN
U
L C DO T
A D OU
A NU
E B
UA
I P ST
INTOU
ET VA IC
NO
taD a
I utnp
R NU E
FA G
LL H-
5024
- z
10 0V~ 60
0
a5
x0 - 2 50 A m
S
2 A 0
T1 5 FU E L ~V
S AE L R NI
v aS r ci e tD a
e
SBU
BS UAE E
6 Bd-
CONNEXIONS DU PANNEAU ARRIEgraveRE
1586 75 141210 11 13 169 17
14) Connecteur ldquo USBrdquoCe connecteur USB (type B) permet de connecter le processeur agrave un ordinateur pour le controcircle et la mise agrave jour du micrologiciel via un programme deacutedieacute (DVA Network)
15) PRISE DALIMENTATION MAINSPermet la connexion du cacircble dalimentation fourni de seacuterie
16) PORTE-FUSIBLE FUSELogement pour fusible de ligne
17) INTERRUPTEUR GENERAL POWERLinterrupteur permet de mettre en marche ou deacuteteindre le controcircleur audio
COMMANDES ET FONCTIONS
5) SELECTEUR ldquo-6dBrdquoLe seacutelecteur permet de reacuteduire de 6dB les niveaux dentreacutee analogiques XLR [6] tout en compensant les niveaux eacuteleveacutes de sortie des meacutelangeurs ou dautres dispositifs audio Quand la barre du niveau de signal des entreacutees sur laffichage [1] reste au maximum cela indique que le niveau du signal entrant est eacuteleveacute Il est alors conseilleacute dutiliser latteacutenuation -6dBIl est possible de veacuterifier quand le seacutelecteur est activeacute par le menu Option
6) CONNECTEURS DENTREE ldquoArdquo ET ldquoBrdquoEntreacutees eacutequilibreacutees au niveau de la ligneIls sont en mesure daccepter des connecteurs XLR macircles
7) CONNECTEURS DE SORTIE ldquo1rdquo ldquo2rdquo ldquo3rdquo ldquo4rdquo ldquo5rdquo ET ldquo6rdquoSorties eacutequilibreacutees au niveau de la ligne Ils sont en mesure daccepter des connecteurs XLR femelles
Prendre garde agrave brancher convenablement les sorties sur les diffuseurs ou les amplificateurs en fonction des configurations de chaque canal pour eacuteviter des deacutegacircts et des problegravemes de fonctionnement
Section ldquoAESEBUrdquo
8) CONNECTEUR DENTREE INOutre les entreacutees audio analogiques une entreacutee audio numeacuterique SPDIF-AESEBU (AES3) a eacuteteacute preacutevue et peut ecirctre seacutelectionneacutee par le menu de setupLentreacutee requiert une connexion eacutequilibreacutee en utilisant un connecteur XLR avec un cacircble agrave 3 conducteurs de 110ohm torsadeacute
9) CONNECTEUR DE SORTIE OUTCe connecteur permet de relancer le signal audio dans les entreacutees analogiques ou numeacuteriques ou sur les sorties La source doit ecirctre reacutegleacutee par le menu OptionLa connexion sera conforme agrave la mecircme norme que lentreacutee [reacutef8]
Section ldquoRDNETrdquo
10) CONNECTEUR DENTREE DATA INPUTConnecteur RJ45 entreacutee de donneacutees
11) CONNECTEUR DE SORTIE DATA LINKConnecteur RJ45 sortie de donneacutees pour la connexion de seacuterie en cascade
12) VOYANT LUMINEUX ONCe voyant de couleur verte sallume uniquement quand lAC26N a reconnu et est connecteacute agrave luniteacute principale RDNET par lordinateur
13) VOYANT LUMINEUX ACTIVECe voyant de couleur jaune clignote quand une transmission des donneacutees est active entre RDNET et le dispositif
PUSH
P SHU
SHPU
P SHU
PUSH
CONNEXIONS
Audio analogiquesLes connexions eacutequilibreacutees permettent de reacuteduire au minimum le bruit provoqueacute par les cacircbles et dutiliser de longs cacircblesCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLe connecteur XLR doit ecirctre brancheacute avec la broche 1 agrave la masse la broche 2 au chaud (+) et la broche 3 au froid (-) En cas de cacircble blindeacute brancher le blindage agrave la broche 1Les cacircbles de connexion XLR-XLR et XLR-Jack14(63mm) peuvent semployer pour la connexion agrave lAC26N
12
3
Entreacutee
Entreacutee
XLR - femme
XLR - femme
1 2
3
Sortie
Sortie
XLR - Macircle
XLR - Macircle
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 1 =B Masselindeacute
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2=Point chaudPhase +VE
Broche 2 = Point chaudPhase +VE
Broche 3 =Point froidPhase -VE
Broche 3 =Point froidPhase -VE
Anneau
Manchon
Pointe Point chaudPhase +VE
Anneau = Point froidPhase -VE
ManchonB Masselindeacute
Pointe
Les connexions deacuteseacutequilibreacutees peuvent semployer mecircme si le bruit provoqueacute par les cacircbles augmente Les cacircbles ne peuvent deacutepasser 5m de longCes connexions peuvent semployer tant sur les entreacutees que sur les sortiesLes connexions deacuteseacutequilibreacutees peuvent abaisser le niveau du signal entrant de 6dB Pour remeacutedier agrave cet inconveacutenient il faut brancher la broche 3 agrave la masse mecircme si cela augmente le bruit
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
45
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
46
12
3
1 2
3
Pointe Manchon
Pointe = Signal
Broche 3 = Link to Pin 1
Broche 3 = Link to Pin 1
ManchonB Masselindeacute
Audio numeacuteriques (AESEBU)
AESEBU (protocole AES3) est une entreacutee eacutequilibreacutee isoleacutee eacutelectriquement agrave laide dun transformateur Elle permet demployer deux canaux audio dans un seul cacircble bipolaire blindeacute Les caracteacuteristiques du cacircble doivent ecirctre de 3 pocircles impeacutedance 100ohm torsadeacute et blindeacute avec connecteur XLR (AES3 standard)
RJ 45
|1|2|3|4|5|6|7|8|
RDnet
Chaque port RDNet des Control 2 et Control 8 peut ecirctre brancheacute agrave un maximum de 32 dispositifs compatibles placeacutes en cascade Dans lexemple suivant le port de luniteacute de controcircle RDNET CONTROL 2 est relieacute agrave lentreacutee DATA INPUT dun AC26N dont la sortie parallegravele DATA LINK est envoyeacutee agrave lentreacutee de lAC26N successif Dans lexemple [n] est un nombre compris entre 3 et 32 (limite maximale des dispositifs que lon peut relier agrave un sous-reacuteseau)
La longueur totale du cacircble CAT5 dun sous-reacuteseau NE peut PAS deacutepasser 900 megravetres
Le connecteur doit ecirctre relieacute comme 1 ndash disponible pour dautres fonctions (par exemple audio +) 2 ndash disponible pour dautres fonctions (par exemple audio )3 ndash disponible pour dautres fonctions (par exemple masse analogique)4 ndash masse numeacuterique5 ndash masse numeacuterique6 ndash disponible pour dautres fonctions (par exemple alimentation)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
MISE EN MARCHE
Lors de la mise en marche du dispositif linitialisation deacutebute et dure quelques secondes Leacutecran affiche le modegravele le logo et la barre de progression du chargement du programme
En fin de processus dinstallation leacutecran affiche la fenecirctre du menu Meters Pour connaicirctre les indications en deacutetail consulter le paragraphe DESCRIPTION FENETRE MENU Meters
LAC26N est precirct agrave lemploi
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION ET VISUALISATION
Pour entrer dans la fenecirctre du menu principal il faut pousser sur la touche MENU ( ) agrave lavant du dispositifDune page quelconque du menu en poussant sur la touche ESCrdquo ( ) on revient automatiquement sur la page-eacutecran preacuteceacutedente
MENU PRINCIPAL
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Le processeur contient six menus Ils montrent etou configurent les paramegravetres du systegravemeLes menus principaux sont
Meters Visualisation des niveaux des entreacutees et des sorties visualisation du programme utiliseacute et eacutetat mute rapide
Preset Meacutemoriser enregistrer et eacuteliminer les configurations du systegraveme
Matrix seacutelectionner les sorties en fonction du signal entrant
Ch Job configuration de chaque signal
X-Over configurer les freacutequences de coupure et les types de filtres pour chaque sortie
Option attribution des entreacutees et des sorties contraste daffichage la version du micrologiciel les entreacutees et dautres options
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
47
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
48
DESCRIPTION DE LA FENETRE MENU Metersrdquo
Cette fenecirctre permet de visualiser les configurations et leacutetat geacuteneacuteral des entreacutees et des sorties la version du programme utiliseacute son eacutetat et le mode de pilotage du systegraveme
Les menus et les options afficheacutees peuvent se seacutelectionner en tournant la manette ldquoFUNCTIONS SETECTORrdquo ( ) Pour avoir accegraves agrave linteacuterieur de la seacutelection il faut mettre le paramegravetre souhaiteacute en eacutevidence et pousser sur la manette ldquoPush Enterrdquo ( | ) Il faut en faire de mecircme pour seacutelectionner etou modifier les options dans les commandes du menu
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositifAvec des signaux dentreacutee numeacuteriques les indications ldquoArdquo et ldquoBrdquo correspondent agrave lentreacuteeEn tournant la manette ldquoFUNCTIONS SELECTORrdquo [2] on fait deacutefiler en mode cyclique les canaux dentreacutee de sortie et lindication de mute geacuteneacuteral (d) le canal seacutelectionneacute est mis en eacutevidence
b) BARRE DE NIVEAU DE COMPRESSIONMUTE CANAL
COMPRESSION DE SIGNALLa compression du signal est visualiseacutee par le deacutefilement de la barre de droite de haut en bas
MUTE Chaque canal peut ecirctre placeacute en mute Seacutelectionner le canal et pousser sur la manette ldquoPush Enterrdquo [2] pour valider le changement deacutetat Lindication du canal sera remplaceacutee par la lettre M et la barre sera totalement mise en eacutevidencePour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterations
c) BARRE DE NIVEAU DE SIGNALLindication du niveau de chaque canal est signaleacutee par le deacutefilement de la barre de gauche
d) MUTE GENERALIl est possible de mettre simultaneacutement toutes les entreacutees et les sorties en mute Tourner la manette ldquoFUNCTIONS SELECTORrdquo seacutelectionner la lettre M et pousser sur la manette Push EnterPour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterationsLe mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) MODES DE COMMANDEIl affiche le mode dutilisation etou les dispositifs qui sont relieacutes agrave lAC26N
Local = utilisation autonome Aucune connexion agrave un dispositif exteacuterieur
NET = relieacute directement au reacuteseau deacutedieacute RDNet et agrave lordinateur
USB = relieacute directement agrave un ordinateur par cacircble USB
f) INDICATION DETAT DE PARAMETRAGECette indication permet de constater si un ou plusieurs paramegravetre(s) du programme chargeacute aont eacuteteacute modifieacute(s) par rapport au dernier sauvetage
= programme dorigine
= programme avec des paramegravetres modifieacutes
g) PROGRAMME CONFIGURELe chiffre indique le programme chargeacute et utiliseacute par le systegraveme agrave lemplacement de sauvetage Consulter le menu de Preset pour de plus amples deacutetails
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
DESCRIPTION DE LA FENETRE MENU Ch Job
Cette fenecirctre permet dafficher la configuration de chaque canal
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) NIVEAU DU SIGNALIndique le gain du signal Laugmentation de lintensiteacute dun signal est libelleacutee en deacutecibel (dB) Le paramegravetre peut ecirctre seacutelectionneacute de -8000dB agrave +2000dB avec des pas de 001dB Une augmentation de 6dB est eacutegale approximativement au redoublement agrave leacutechelle lineacuteaire du niveau du signal sous tensionAvec un gain supeacuterieur agrave 0dB le signal est amplifieacute tandis quavec un gain infeacuterieur agrave 0dB le signal est atteacutenueacute
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
49
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
50
c) DELAI DU SIGNAL (DELAY)Le signal audio reproduit peut ecirctre retardeacute pour permettre lalignement acoustique Cela compense les diffeacuterentes positions des diffuseurs pendant linstallation et la reproduction sonore Il se libelle en mS Le paramegravetre peut ecirctre seacutelectionneacute de 00mS agrave 729mS avec un pas de 01mSPour aligner un signal audio il est possible dutiliser la formule suivante
Deacutelai = (GAPx1000)344
Deacutelai = ms (en millisecondes)GAP = distance du diffuseur du point de reacutefeacuterence (en megravetres)Vitesse du son = 344ms
d) MUTEChaque canal peut ecirctre placeacute en mute La mecircme commande peut ecirctre activeacutee dans la fenecirctre du menu meters NB Le mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) PhasePermet la rotation de phase de 180deg par rapport au signal entrantCette rotation permet loptimisation surtout des basses freacutequences dans les installations complexes
f) EGALISATIONCette commande ouvre la fenecirctre du menu deacutegalisation de chaque canal Elle sert surtout pour corriger une ou plusieurs freacutequences qui doivent ecirctre atteacutenueacutees ou augmenteacutees
M M
LAC26N gegravere 12 filtres par canal dentreacutee et sortie avec trois types de configurations diffeacuterentes - Leacutegaliseur PEQ (peaking equalizer) est ideacuteal pour identifier isoler et
corriger une seule plage de freacutequences bien deacutetermineacutee Toutes les freacutequences passent mais il augmente ou diminue uniquement celles autour de la freacutequence centrale pour une bande preacutecise et un gain deacutefini
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessus de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessous de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
f Numeacuterotation des 12 filtres disponibles pour cette entreacutee ou cette sortie1
f Le type de filtre est afficheacute 2
Dis Deacutesactiveacute (absent)
PEQ Peaking equlizer
Sh H Filtre high-shelf
Sh L Filtre high-shelf
Exemples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
REMARQUELe paramegravetre Bw deacutetermine le champ de freacutequences adjacent agrave la freacutequence configureacutee ougrave est activeacute le filtre Plus la valeur Bw est eacuteleveacutee plus vaste est le champ de freacutequences (1Bw=1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONCette commande ouvre la fenecirctre du menu de compression de chaque canal
g1) TresholdIdentifie le seuil ougrave commence le rapport de compression La valeur de base 11
g2) RatioIndique le rapport de conversion entre le signal entrant et le signal sortant
g3) Post Gain Attach Release HoldCes donneacutees deacutependent du rapport de conversion que lon veut obtenir - Post Gain est le gain de sortie- Attack est le temps dattaque - Release est le temps de relacircchement- Hold est le temps de maintien
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
52
DESCRIPTION DE LA FENETRE MENU Preset
Cette fenecirctre permet de meacutemoriser jusquagrave 32 configurations dans lAC26NLe fabricant fournit le systegraveme avec un programme configureacute et enregistreacute en position 0 et non susceptible deacutecrasement
032 Elle indique lemplacement de sauvetage de la configurationCe numeacutero apparaicirct dans la fenecirctre Meters en position (g) A tout moment le programme utiliseacute peut ecirctre afficheacute par lutilisateur
Empty Preset Cest le nom qui est associeacute au numeacutero de lemplacement quand aucune configuration (vide) nest enregistreacutee
Local preset Local preset est le nom qui est associeacute au numeacutero de lemplacement quand on enregistre une configuration NB = Il est possible denregistrer une configuration avec lenom souhaiteacute de 16 lettres tout au plus agrave condition que lonutilise linterface via lordinateur
Le nom du programme assigneacute est indiqueacutePour toucher agrave lapplication 3 choix soffrent agrave vous
Save Le programme est enregistreacute en meacutemoire de lAC26N
Del Le programme est effaceacute
Load Le programme est chargeacute et precirct agrave lemploi
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
51
DESCRIPTION DE LA FENETRE MENU X-Over
Cette fenecirctre permet de seacutelectionner un filtre passe bas un filtre passe haut ou par la combinaison des deux de creacuteer un filtre passe bande pour chaque sortieLe filtre actif est un Linkwitz-Riley qui permet de seacutelectionner la pente de 12dBoct 24dBoct ou 48dBoct et sa freacutequence de coupure
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) CANAUX DE SORTIE
Les connecteurs de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) FILTRE CROSSOVERSeacutelectionner le filtre selon les besoins Il est possible de seacutelectionner
Dis Aucun filtre activeacute
HP Filtre passe-haut laisse passer uniquement la partie de signal audio supeacuterieure agrave la freacutequence de coupure
LP Filtre passe-bas laisse passer uniquement la partie de signal audio infeacuterieure agrave la freacutequence de coupure
Configuration du filtre Passe-haut Passe-bas
Rien Dis Dis
Passe-haut HP Dis
Passe-bas Dis LP
Passe-bande HP LP
12dBoct
24dBoct
Hz
dB
Ga
in 48dBoct
12dBoct
24dBoct
Hz
dB
Ga
in
48dBoct
c) PENTE DATTENUATIONSeacutelectionner la pente datteacutenuation du signal audio en fonction de la diminution que lon veut obtenir Plus la pente datteacutenuation est eacuteleveacutee agrave eacutegaliteacute de freacutequence de coupure plus eacuteleveacutee sera la seacutelection du signal Il est possible de seacutelectionner
12 correspond agrave 12dboct
24 correspond agrave 24dboct
48 correspond agrave 48dboct
d) FREQUENCE DE COUPUREElle permet de reacutegler la freacutequence de passage des freacutequences infeacuterieures (filtre passe-bas) ou des freacutequences supeacuterieures (filtre passe-haut) uniquementLe choix de la coupure deacutepend de la reproduction que lon veut obtenirLuniteacute de mesure utiliseacutee est lHz
Hz
Hz
dB
dB
Ga
in
f0
f0
0dB0dB
0dB
-6dB
freacutequence
freacutequence
freacutequence
freacutequence
Ga
in
f0
0dB
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
53
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
54
DESCRIPTION DE LA FENETRE MENU Matrix
Elle permet de seacutelectionner le signal entrant agrave utiliser comme source pour chaque sortie
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) CANAUX DE SORTIEIdentification du canal sortant agrave reacutegler
b) IDENTIFICATIONS DES ENTREESSeacutelectionner le type de signal agrave associer agrave chaque sortie en fonction des besoins Il est possible de seacutelectionner
In A Le signal entrant A est associeacute
In B Le signal entrant B est associeacute
In A+B La somme algeacutebrique des deux signaux entrants A et B est associeacutee
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
DESCRIPTION DE LA FENETRE MENU Option
Permet dafficher les reacuteglages du systegraveme comme lassignation des entreacutees et des sorties latteacutenuation le contraste de laffichage et la version du logiciel
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcCette option permet de reacutegler le type de signal audio entrant
An In =signaux audio analogiques (entreacutees ldquoArdquo et ldquoBrdquo)
Dig In =signaux audio numeacuteriques (entreacutee AESEBU)
DigOut SrcCette option permet de seacutelectionner la source audio qui sera adresseacutee sur le connecteur AESEBU OUT (sortie numeacuterique)
An In = signaux audio des entreacutees analogiques
Dig In =signaux audio sur lentreacutee numeacuterique
OUT 1-2 = signaux audio sur les sorties 1 et 2
OUT 3-4 = signaux audio sur les sorties 3 et 4
OUT 5-6 = signaux audio sur les sorties 5 et 6
Input ModePermet de configurer les entreacutees
Indip = sont indeacutependantes et autonomes Ne sont soumises agrave aucun type de lien
Linked = sont unies et fonctionnent en mode steacutereacuteo Les compresseurs les filtres les deacutelais le volume sont identiques pour les deux canaux
Atten PadIndique le mode de reacuteglage du seacutelecteur ldquo-6dBrdquo placeacute agrave larriegravere [reacutef 5] Il faut activer ce seacutelecteur quand les niveaux dentreacutee analogiques sont trop eacuteleveacutes Le seacutelecteur sactive uniquement par le bouton Dans le menu il sagit dune simple visualisation
0dB = seacutelecteur non activeacute Les signaux dentreacutee sont identiques agrave la source entrante
-6dB = seacutelecteur activeacute Les signaux entrants sont atteacutenueacutes de -6dB par le processeur interne
ContrastIl permet de reacutegler le contraste de laffichage agrave cristaux liquides pour compenser la diffeacuterence de luminositeacute avec le lieu dinstallation Une plus grande clarteacute de laffichage permet de naviguer convenablement et rapidement dans les menusLe reacuteglage agrave la sortie de lusine du fabricant est de 60
10 plus clair 60 plus fonceacute 100
Fw VersIndique la version du logiciel du processeur
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
55
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
56
DONNES TECHINIQUES
PERFORMANCES AUDIOReacuteponse en freacutequence +- 01dB (20 to 30kHz)Plage dynamique 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsion 0002 (1kHz +4dBu)
PERFORMANCES AUDIO NUMERIQUES Processeur DSP 2856-bit Freacutequence de traitement des donneacutees 48KHzConvertisseurs analogiques 24-bit BURR BROWNDeacutelai de propagation 15msMeacutemorisations des configurations 32 preset
CONTROLES Affichage LCD graficoBoutonsCommandes ESC - MENU - FUNCTIONS SELECTION
ENTERENTREESSORTIESEntreacutee analogique ndeg2 x XLR (3 broches femelle)
Impeacutedance dentreacutee gt10KOhmNiveau maximum +21dBu senza PAD
+27dBu con PADSortie analogique ndeg6 x XLR (3 broches macircle )
Impeacutedance de sortie 50OhmNiveau maximum +21dBuType Balanceacute
Entreacutee numeacuterique ndeg1x XLR (3 broches femelle)Type SPDIF-AESEBU (AES3)
Sortie numeacuterique ndeg1x XLR (3 broches macircle )Type conforme agrave la norme de lentreacutee
EntreacuteesSortie Rdnet ndeg2 x XLR RJ45 (cacircble CAT 5)USB Type B
PARAMETRES DE CONTROLE DU SONGain -80dB a +20dB eacutetape 01dBDeacutelai Entreacutee 0 a 729mS eacutetape 01 mS
Sortie 0 a 340mS eacutetape 01mSRotation de phase 0deg - 180deg
COMPRESSIONSeuil -80dB a +20dB eacutetape 01dBRapport 11 a Inf1 eacutetape 001Gain agrave la sortie 0dB a 40dB eacutetape 01dBTemps dattaque 1mS a 1000mS eacutetape 01mSTemps de relacircchement 1mS a 1000mS eacutetape 01mSTemps de maintien 1mS a 1000mS eacutetape 01mS
EGALISEURS12 eacutegaliseurs pour chaque entreacutee et sortieType PEQ (parameacutetrique) Hi-shelf Lo-sheft
Freacutequence 20Hz a 20KHz eacutetape 1HzGain -30dB a +15dB eacutetape 001dBBande 005dB a 2dB eacutetape 001dB (uniquement pour PEQ)
FILTRES CROSSOVERFiltre Linkwitz Riley
Type HF high-shelfLF low-shelf
Pente 12dBoct - 24dBoct - 48dBoctFreacutequence de coupure 5Hz a 20KHz eacutetape 1Hz
ALIMENTATION Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)POIDS 19Kg
Remarques Speacutecifications sujettes agrave modifications sans preacuteavis
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
2 VIE ATTIVO2 WAY ACTIVE
3 VIE PASSIVO3 WAY PASSIVE
L
L
A
A
HIGH L
MID L
LOW HIGHMID RHIGHMID L
LOW L
HIGH R
MID R
LOW R
R
R
B
B
1
1
2
2
3
3
456
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
Menu Matrix configurationMatrix
57 58
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
EROUIG ATRIX TNM
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
OU
TP
UT
1
OU
TP
UT
2
OU
TP
UT
3
OU
TP
UT
4
OU
TP
UT
5
OU
TP
UT
6
AE
S-E
BU
OU
TP
UT
INP
UT
A
AE
S-E
BU
INP
UT
INP
UT
B
D D D D D D
D D
A A A A A A
A SA
MP
LE
RA
TE
CO
NV
A
LIN
KA
BL
E
SC
HE
MA
A B
LO
CC
HI -
BL
OC
K D
IAG
RA
MB
LO
CK
SC
HA
LT
BIL
D -
SC
HE
MA
S F
ON
CT
ION
NE
LS
LINE ARRAY SUB MONO ATTIVO
LINE ARRAY SUB MONO ACTIVEINGRESSI - INPUT
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
L
L
L
A
A
A
AESEBU IN
AESEBU IN
AESEBU IN
AESEBU OUT
AESEBU IN
AESEBU IN
AESEBU OUT
R
R
R
LR
B
B
B
123456
HIGHMID L
HIGHMID L HIGHMID R
HIGHMID R
LOW L LOW R
LAYER
DISPLAY MEMORY
FADER MODE
LAYER
DISPLAY MEMORY
FADER MODE
Ingresso ANALOGICO
ANALOG Input
Collegamento in cascata
Link connections
Ingresso DIGITALE
DIGITAL inputA B
BALANCED AUDIO INPUTS
-6dB
PUSH PUSH
IN OUT
AES EBUPUSH
Oppure
or
Oppure
or
Menu Option configurationOption
Menu Option configurationOption Menu Option configurationOption
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type Analog
AES out An In
Input type Analog
AES out An In
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
59 60
InA-B Src Dig InInA-B Src Dig InInA-B Src An InInA-B Src An In
frequenzaHz
dB
Gu
ad
ag
no
60 200 2800
0dB0dB
-6dB
Esempio di un sistema a 3-vie
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
Out 1 Out 2 Out 3
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Esempio di un sistema a 3-vie
61 62
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
26NAC 26NAC
R TE
DO
R
MO LEU O R CE S
E O TR L A
S O
O C ND I P
P hsuernE t
o su cti nF nel rS e tc o
E CSME UN
IGCHTE OL SN EOBd
ocaL l
M
0
484
467
430
44
31
75
12
7
DIMENSIONI DIMENSIONSABMESSUNGEN DIMENSIONS
Audio numeacuteriques (AESEBU)
AESEBU (protocole AES3) est une entreacutee eacutequilibreacutee isoleacutee eacutelectriquement agrave laide dun transformateur Elle permet demployer deux canaux audio dans un seul cacircble bipolaire blindeacute Les caracteacuteristiques du cacircble doivent ecirctre de 3 pocircles impeacutedance 100ohm torsadeacute et blindeacute avec connecteur XLR (AES3 standard)
RJ 45
|1|2|3|4|5|6|7|8|
RDnet
Chaque port RDNet des Control 2 et Control 8 peut ecirctre brancheacute agrave un maximum de 32 dispositifs compatibles placeacutes en cascade Dans lexemple suivant le port de luniteacute de controcircle RDNET CONTROL 2 est relieacute agrave lentreacutee DATA INPUT dun AC26N dont la sortie parallegravele DATA LINK est envoyeacutee agrave lentreacutee de lAC26N successif Dans lexemple [n] est un nombre compris entre 3 et 32 (limite maximale des dispositifs que lon peut relier agrave un sous-reacuteseau)
La longueur totale du cacircble CAT5 dun sous-reacuteseau NE peut PAS deacutepasser 900 megravetres
Le connecteur doit ecirctre relieacute comme 1 ndash disponible pour dautres fonctions (par exemple audio +) 2 ndash disponible pour dautres fonctions (par exemple audio )3 ndash disponible pour dautres fonctions (par exemple masse analogique)4 ndash masse numeacuterique5 ndash masse numeacuterique6 ndash disponible pour dautres fonctions (par exemple alimentation)7 ndash RS 485 A8 ndash RS 485 B
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
DataLink ACTIVE
ON
DataInput
PUSH PUSH
CH 1
RDNETCONTROL 2 AC26N [1] AC26N [2] AC26N [n]
PUSH
MISE EN MARCHE
Lors de la mise en marche du dispositif linitialisation deacutebute et dure quelques secondes Leacutecran affiche le modegravele le logo et la barre de progression du chargement du programme
En fin de processus dinstallation leacutecran affiche la fenecirctre du menu Meters Pour connaicirctre les indications en deacutetail consulter le paragraphe DESCRIPTION FENETRE MENU Meters
LAC26N est precirct agrave lemploi
LocalLocal
0
TECHNOLOGIESTECHNOLOGIESRDNET
AC26N
V 071
A B 1 2 3 4 5 6
CONFIGURATION ET VISUALISATION
Pour entrer dans la fenecirctre du menu principal il faut pousser sur la touche MENU ( ) agrave lavant du dispositifDune page quelconque du menu en poussant sur la touche ESCrdquo ( ) on revient automatiquement sur la page-eacutecran preacuteceacutedente
MENU PRINCIPAL
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
Le processeur contient six menus Ils montrent etou configurent les paramegravetres du systegravemeLes menus principaux sont
Meters Visualisation des niveaux des entreacutees et des sorties visualisation du programme utiliseacute et eacutetat mute rapide
Preset Meacutemoriser enregistrer et eacuteliminer les configurations du systegraveme
Matrix seacutelectionner les sorties en fonction du signal entrant
Ch Job configuration de chaque signal
X-Over configurer les freacutequences de coupure et les types de filtres pour chaque sortie
Option attribution des entreacutees et des sorties contraste daffichage la version du micrologiciel les entreacutees et dautres options
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
47
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
48
DESCRIPTION DE LA FENETRE MENU Metersrdquo
Cette fenecirctre permet de visualiser les configurations et leacutetat geacuteneacuteral des entreacutees et des sorties la version du programme utiliseacute son eacutetat et le mode de pilotage du systegraveme
Les menus et les options afficheacutees peuvent se seacutelectionner en tournant la manette ldquoFUNCTIONS SETECTORrdquo ( ) Pour avoir accegraves agrave linteacuterieur de la seacutelection il faut mettre le paramegravetre souhaiteacute en eacutevidence et pousser sur la manette ldquoPush Enterrdquo ( | ) Il faut en faire de mecircme pour seacutelectionner etou modifier les options dans les commandes du menu
INGRESSI USCITE
b
e
a
cf
d
g
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
LocalLocal
0
A B 1 2 3 4 5 6
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositifAvec des signaux dentreacutee numeacuteriques les indications ldquoArdquo et ldquoBrdquo correspondent agrave lentreacuteeEn tournant la manette ldquoFUNCTIONS SELECTORrdquo [2] on fait deacutefiler en mode cyclique les canaux dentreacutee de sortie et lindication de mute geacuteneacuteral (d) le canal seacutelectionneacute est mis en eacutevidence
b) BARRE DE NIVEAU DE COMPRESSIONMUTE CANAL
COMPRESSION DE SIGNALLa compression du signal est visualiseacutee par le deacutefilement de la barre de droite de haut en bas
MUTE Chaque canal peut ecirctre placeacute en mute Seacutelectionner le canal et pousser sur la manette ldquoPush Enterrdquo [2] pour valider le changement deacutetat Lindication du canal sera remplaceacutee par la lettre M et la barre sera totalement mise en eacutevidencePour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterations
c) BARRE DE NIVEAU DE SIGNALLindication du niveau de chaque canal est signaleacutee par le deacutefilement de la barre de gauche
d) MUTE GENERALIl est possible de mettre simultaneacutement toutes les entreacutees et les sorties en mute Tourner la manette ldquoFUNCTIONS SELECTORrdquo seacutelectionner la lettre M et pousser sur la manette Push EnterPour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterationsLe mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) MODES DE COMMANDEIl affiche le mode dutilisation etou les dispositifs qui sont relieacutes agrave lAC26N
Local = utilisation autonome Aucune connexion agrave un dispositif exteacuterieur
NET = relieacute directement au reacuteseau deacutedieacute RDNet et agrave lordinateur
USB = relieacute directement agrave un ordinateur par cacircble USB
f) INDICATION DETAT DE PARAMETRAGECette indication permet de constater si un ou plusieurs paramegravetre(s) du programme chargeacute aont eacuteteacute modifieacute(s) par rapport au dernier sauvetage
= programme dorigine
= programme avec des paramegravetres modifieacutes
g) PROGRAMME CONFIGURELe chiffre indique le programme chargeacute et utiliseacute par le systegraveme agrave lemplacement de sauvetage Consulter le menu de Preset pour de plus amples deacutetails
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
DESCRIPTION DE LA FENETRE MENU Ch Job
Cette fenecirctre permet dafficher la configuration de chaque canal
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) NIVEAU DU SIGNALIndique le gain du signal Laugmentation de lintensiteacute dun signal est libelleacutee en deacutecibel (dB) Le paramegravetre peut ecirctre seacutelectionneacute de -8000dB agrave +2000dB avec des pas de 001dB Une augmentation de 6dB est eacutegale approximativement au redoublement agrave leacutechelle lineacuteaire du niveau du signal sous tensionAvec un gain supeacuterieur agrave 0dB le signal est amplifieacute tandis quavec un gain infeacuterieur agrave 0dB le signal est atteacutenueacute
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
49
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
50
c) DELAI DU SIGNAL (DELAY)Le signal audio reproduit peut ecirctre retardeacute pour permettre lalignement acoustique Cela compense les diffeacuterentes positions des diffuseurs pendant linstallation et la reproduction sonore Il se libelle en mS Le paramegravetre peut ecirctre seacutelectionneacute de 00mS agrave 729mS avec un pas de 01mSPour aligner un signal audio il est possible dutiliser la formule suivante
Deacutelai = (GAPx1000)344
Deacutelai = ms (en millisecondes)GAP = distance du diffuseur du point de reacutefeacuterence (en megravetres)Vitesse du son = 344ms
d) MUTEChaque canal peut ecirctre placeacute en mute La mecircme commande peut ecirctre activeacutee dans la fenecirctre du menu meters NB Le mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) PhasePermet la rotation de phase de 180deg par rapport au signal entrantCette rotation permet loptimisation surtout des basses freacutequences dans les installations complexes
f) EGALISATIONCette commande ouvre la fenecirctre du menu deacutegalisation de chaque canal Elle sert surtout pour corriger une ou plusieurs freacutequences qui doivent ecirctre atteacutenueacutees ou augmenteacutees
M M
LAC26N gegravere 12 filtres par canal dentreacutee et sortie avec trois types de configurations diffeacuterentes - Leacutegaliseur PEQ (peaking equalizer) est ideacuteal pour identifier isoler et
corriger une seule plage de freacutequences bien deacutetermineacutee Toutes les freacutequences passent mais il augmente ou diminue uniquement celles autour de la freacutequence centrale pour une bande preacutecise et un gain deacutefini
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessus de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessous de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
f Numeacuterotation des 12 filtres disponibles pour cette entreacutee ou cette sortie1
f Le type de filtre est afficheacute 2
Dis Deacutesactiveacute (absent)
PEQ Peaking equlizer
Sh H Filtre high-shelf
Sh L Filtre high-shelf
Exemples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
REMARQUELe paramegravetre Bw deacutetermine le champ de freacutequences adjacent agrave la freacutequence configureacutee ougrave est activeacute le filtre Plus la valeur Bw est eacuteleveacutee plus vaste est le champ de freacutequences (1Bw=1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONCette commande ouvre la fenecirctre du menu de compression de chaque canal
g1) TresholdIdentifie le seuil ougrave commence le rapport de compression La valeur de base 11
g2) RatioIndique le rapport de conversion entre le signal entrant et le signal sortant
g3) Post Gain Attach Release HoldCes donneacutees deacutependent du rapport de conversion que lon veut obtenir - Post Gain est le gain de sortie- Attack est le temps dattaque - Release est le temps de relacircchement- Hold est le temps de maintien
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
52
DESCRIPTION DE LA FENETRE MENU Preset
Cette fenecirctre permet de meacutemoriser jusquagrave 32 configurations dans lAC26NLe fabricant fournit le systegraveme avec un programme configureacute et enregistreacute en position 0 et non susceptible deacutecrasement
032 Elle indique lemplacement de sauvetage de la configurationCe numeacutero apparaicirct dans la fenecirctre Meters en position (g) A tout moment le programme utiliseacute peut ecirctre afficheacute par lutilisateur
Empty Preset Cest le nom qui est associeacute au numeacutero de lemplacement quand aucune configuration (vide) nest enregistreacutee
Local preset Local preset est le nom qui est associeacute au numeacutero de lemplacement quand on enregistre une configuration NB = Il est possible denregistrer une configuration avec lenom souhaiteacute de 16 lettres tout au plus agrave condition que lonutilise linterface via lordinateur
Le nom du programme assigneacute est indiqueacutePour toucher agrave lapplication 3 choix soffrent agrave vous
Save Le programme est enregistreacute en meacutemoire de lAC26N
Del Le programme est effaceacute
Load Le programme est chargeacute et precirct agrave lemploi
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
51
DESCRIPTION DE LA FENETRE MENU X-Over
Cette fenecirctre permet de seacutelectionner un filtre passe bas un filtre passe haut ou par la combinaison des deux de creacuteer un filtre passe bande pour chaque sortieLe filtre actif est un Linkwitz-Riley qui permet de seacutelectionner la pente de 12dBoct 24dBoct ou 48dBoct et sa freacutequence de coupure
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) CANAUX DE SORTIE
Les connecteurs de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) FILTRE CROSSOVERSeacutelectionner le filtre selon les besoins Il est possible de seacutelectionner
Dis Aucun filtre activeacute
HP Filtre passe-haut laisse passer uniquement la partie de signal audio supeacuterieure agrave la freacutequence de coupure
LP Filtre passe-bas laisse passer uniquement la partie de signal audio infeacuterieure agrave la freacutequence de coupure
Configuration du filtre Passe-haut Passe-bas
Rien Dis Dis
Passe-haut HP Dis
Passe-bas Dis LP
Passe-bande HP LP
12dBoct
24dBoct
Hz
dB
Ga
in 48dBoct
12dBoct
24dBoct
Hz
dB
Ga
in
48dBoct
c) PENTE DATTENUATIONSeacutelectionner la pente datteacutenuation du signal audio en fonction de la diminution que lon veut obtenir Plus la pente datteacutenuation est eacuteleveacutee agrave eacutegaliteacute de freacutequence de coupure plus eacuteleveacutee sera la seacutelection du signal Il est possible de seacutelectionner
12 correspond agrave 12dboct
24 correspond agrave 24dboct
48 correspond agrave 48dboct
d) FREQUENCE DE COUPUREElle permet de reacutegler la freacutequence de passage des freacutequences infeacuterieures (filtre passe-bas) ou des freacutequences supeacuterieures (filtre passe-haut) uniquementLe choix de la coupure deacutepend de la reproduction que lon veut obtenirLuniteacute de mesure utiliseacutee est lHz
Hz
Hz
dB
dB
Ga
in
f0
f0
0dB0dB
0dB
-6dB
freacutequence
freacutequence
freacutequence
freacutequence
Ga
in
f0
0dB
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
53
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
54
DESCRIPTION DE LA FENETRE MENU Matrix
Elle permet de seacutelectionner le signal entrant agrave utiliser comme source pour chaque sortie
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) CANAUX DE SORTIEIdentification du canal sortant agrave reacutegler
b) IDENTIFICATIONS DES ENTREESSeacutelectionner le type de signal agrave associer agrave chaque sortie en fonction des besoins Il est possible de seacutelectionner
In A Le signal entrant A est associeacute
In B Le signal entrant B est associeacute
In A+B La somme algeacutebrique des deux signaux entrants A et B est associeacutee
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
DESCRIPTION DE LA FENETRE MENU Option
Permet dafficher les reacuteglages du systegraveme comme lassignation des entreacutees et des sorties latteacutenuation le contraste de laffichage et la version du logiciel
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcCette option permet de reacutegler le type de signal audio entrant
An In =signaux audio analogiques (entreacutees ldquoArdquo et ldquoBrdquo)
Dig In =signaux audio numeacuteriques (entreacutee AESEBU)
DigOut SrcCette option permet de seacutelectionner la source audio qui sera adresseacutee sur le connecteur AESEBU OUT (sortie numeacuterique)
An In = signaux audio des entreacutees analogiques
Dig In =signaux audio sur lentreacutee numeacuterique
OUT 1-2 = signaux audio sur les sorties 1 et 2
OUT 3-4 = signaux audio sur les sorties 3 et 4
OUT 5-6 = signaux audio sur les sorties 5 et 6
Input ModePermet de configurer les entreacutees
Indip = sont indeacutependantes et autonomes Ne sont soumises agrave aucun type de lien
Linked = sont unies et fonctionnent en mode steacutereacuteo Les compresseurs les filtres les deacutelais le volume sont identiques pour les deux canaux
Atten PadIndique le mode de reacuteglage du seacutelecteur ldquo-6dBrdquo placeacute agrave larriegravere [reacutef 5] Il faut activer ce seacutelecteur quand les niveaux dentreacutee analogiques sont trop eacuteleveacutes Le seacutelecteur sactive uniquement par le bouton Dans le menu il sagit dune simple visualisation
0dB = seacutelecteur non activeacute Les signaux dentreacutee sont identiques agrave la source entrante
-6dB = seacutelecteur activeacute Les signaux entrants sont atteacutenueacutes de -6dB par le processeur interne
ContrastIl permet de reacutegler le contraste de laffichage agrave cristaux liquides pour compenser la diffeacuterence de luminositeacute avec le lieu dinstallation Une plus grande clarteacute de laffichage permet de naviguer convenablement et rapidement dans les menusLe reacuteglage agrave la sortie de lusine du fabricant est de 60
10 plus clair 60 plus fonceacute 100
Fw VersIndique la version du logiciel du processeur
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
55
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
56
DONNES TECHINIQUES
PERFORMANCES AUDIOReacuteponse en freacutequence +- 01dB (20 to 30kHz)Plage dynamique 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsion 0002 (1kHz +4dBu)
PERFORMANCES AUDIO NUMERIQUES Processeur DSP 2856-bit Freacutequence de traitement des donneacutees 48KHzConvertisseurs analogiques 24-bit BURR BROWNDeacutelai de propagation 15msMeacutemorisations des configurations 32 preset
CONTROLES Affichage LCD graficoBoutonsCommandes ESC - MENU - FUNCTIONS SELECTION
ENTERENTREESSORTIESEntreacutee analogique ndeg2 x XLR (3 broches femelle)
Impeacutedance dentreacutee gt10KOhmNiveau maximum +21dBu senza PAD
+27dBu con PADSortie analogique ndeg6 x XLR (3 broches macircle )
Impeacutedance de sortie 50OhmNiveau maximum +21dBuType Balanceacute
Entreacutee numeacuterique ndeg1x XLR (3 broches femelle)Type SPDIF-AESEBU (AES3)
Sortie numeacuterique ndeg1x XLR (3 broches macircle )Type conforme agrave la norme de lentreacutee
EntreacuteesSortie Rdnet ndeg2 x XLR RJ45 (cacircble CAT 5)USB Type B
PARAMETRES DE CONTROLE DU SONGain -80dB a +20dB eacutetape 01dBDeacutelai Entreacutee 0 a 729mS eacutetape 01 mS
Sortie 0 a 340mS eacutetape 01mSRotation de phase 0deg - 180deg
COMPRESSIONSeuil -80dB a +20dB eacutetape 01dBRapport 11 a Inf1 eacutetape 001Gain agrave la sortie 0dB a 40dB eacutetape 01dBTemps dattaque 1mS a 1000mS eacutetape 01mSTemps de relacircchement 1mS a 1000mS eacutetape 01mSTemps de maintien 1mS a 1000mS eacutetape 01mS
EGALISEURS12 eacutegaliseurs pour chaque entreacutee et sortieType PEQ (parameacutetrique) Hi-shelf Lo-sheft
Freacutequence 20Hz a 20KHz eacutetape 1HzGain -30dB a +15dB eacutetape 001dBBande 005dB a 2dB eacutetape 001dB (uniquement pour PEQ)
FILTRES CROSSOVERFiltre Linkwitz Riley
Type HF high-shelfLF low-shelf
Pente 12dBoct - 24dBoct - 48dBoctFreacutequence de coupure 5Hz a 20KHz eacutetape 1Hz
ALIMENTATION Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)POIDS 19Kg
Remarques Speacutecifications sujettes agrave modifications sans preacuteavis
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
2 VIE ATTIVO2 WAY ACTIVE
3 VIE PASSIVO3 WAY PASSIVE
L
L
A
A
HIGH L
MID L
LOW HIGHMID RHIGHMID L
LOW L
HIGH R
MID R
LOW R
R
R
B
B
1
1
2
2
3
3
456
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
Menu Matrix configurationMatrix
57 58
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
EROUIG ATRIX TNM
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
OU
TP
UT
1
OU
TP
UT
2
OU
TP
UT
3
OU
TP
UT
4
OU
TP
UT
5
OU
TP
UT
6
AE
S-E
BU
OU
TP
UT
INP
UT
A
AE
S-E
BU
INP
UT
INP
UT
B
D D D D D D
D D
A A A A A A
A SA
MP
LE
RA
TE
CO
NV
A
LIN
KA
BL
E
SC
HE
MA
A B
LO
CC
HI -
BL
OC
K D
IAG
RA
MB
LO
CK
SC
HA
LT
BIL
D -
SC
HE
MA
S F
ON
CT
ION
NE
LS
LINE ARRAY SUB MONO ATTIVO
LINE ARRAY SUB MONO ACTIVEINGRESSI - INPUT
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
L
L
L
A
A
A
AESEBU IN
AESEBU IN
AESEBU IN
AESEBU OUT
AESEBU IN
AESEBU IN
AESEBU OUT
R
R
R
LR
B
B
B
123456
HIGHMID L
HIGHMID L HIGHMID R
HIGHMID R
LOW L LOW R
LAYER
DISPLAY MEMORY
FADER MODE
LAYER
DISPLAY MEMORY
FADER MODE
Ingresso ANALOGICO
ANALOG Input
Collegamento in cascata
Link connections
Ingresso DIGITALE
DIGITAL inputA B
BALANCED AUDIO INPUTS
-6dB
PUSH PUSH
IN OUT
AES EBUPUSH
Oppure
or
Oppure
or
Menu Option configurationOption
Menu Option configurationOption Menu Option configurationOption
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type Analog
AES out An In
Input type Analog
AES out An In
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
59 60
InA-B Src Dig InInA-B Src Dig InInA-B Src An InInA-B Src An In
frequenzaHz
dB
Gu
ad
ag
no
60 200 2800
0dB0dB
-6dB
Esempio di un sistema a 3-vie
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
Out 1 Out 2 Out 3
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Esempio di un sistema a 3-vie
61 62
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
26NAC 26NAC
R TE
DO
R
MO LEU O R CE S
E O TR L A
S O
O C ND I P
P hsuernE t
o su cti nF nel rS e tc o
E CSME UN
IGCHTE OL SN EOBd
ocaL l
M
0
484
467
430
44
31
75
12
7
DIMENSIONI DIMENSIONSABMESSUNGEN DIMENSIONS
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositifAvec des signaux dentreacutee numeacuteriques les indications ldquoArdquo et ldquoBrdquo correspondent agrave lentreacuteeEn tournant la manette ldquoFUNCTIONS SELECTORrdquo [2] on fait deacutefiler en mode cyclique les canaux dentreacutee de sortie et lindication de mute geacuteneacuteral (d) le canal seacutelectionneacute est mis en eacutevidence
b) BARRE DE NIVEAU DE COMPRESSIONMUTE CANAL
COMPRESSION DE SIGNALLa compression du signal est visualiseacutee par le deacutefilement de la barre de droite de haut en bas
MUTE Chaque canal peut ecirctre placeacute en mute Seacutelectionner le canal et pousser sur la manette ldquoPush Enterrdquo [2] pour valider le changement deacutetat Lindication du canal sera remplaceacutee par la lettre M et la barre sera totalement mise en eacutevidencePour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterations
c) BARRE DE NIVEAU DE SIGNALLindication du niveau de chaque canal est signaleacutee par le deacutefilement de la barre de gauche
d) MUTE GENERALIl est possible de mettre simultaneacutement toutes les entreacutees et les sorties en mute Tourner la manette ldquoFUNCTIONS SELECTORrdquo seacutelectionner la lettre M et pousser sur la manette Push EnterPour reacutetablir le fonctionnement normal reacutepeacuteter ces mecircmes opeacuterationsLe mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) MODES DE COMMANDEIl affiche le mode dutilisation etou les dispositifs qui sont relieacutes agrave lAC26N
Local = utilisation autonome Aucune connexion agrave un dispositif exteacuterieur
NET = relieacute directement au reacuteseau deacutedieacute RDNet et agrave lordinateur
USB = relieacute directement agrave un ordinateur par cacircble USB
f) INDICATION DETAT DE PARAMETRAGECette indication permet de constater si un ou plusieurs paramegravetre(s) du programme chargeacute aont eacuteteacute modifieacute(s) par rapport au dernier sauvetage
= programme dorigine
= programme avec des paramegravetres modifieacutes
g) PROGRAMME CONFIGURELe chiffre indique le programme chargeacute et utiliseacute par le systegraveme agrave lemplacement de sauvetage Consulter le menu de Preset pour de plus amples deacutetails
AAAA
AA
33
AA MM
0dB
22dBu
-20dB
-60dBu
DESCRIPTION DE LA FENETRE MENU Ch Job
Cette fenecirctre permet dafficher la configuration de chaque canal
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Preset
Matrix
Meters
Preset
Matrix
A 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dBA 135mS
B +650dB 00mS
1 -1000dB 35mS
2 +000dB 00mS
+000dB
a b c d e f g
a) CANAUX DENTREE ET DE SORTIELes connecteurs dentreacutee et de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) NIVEAU DU SIGNALIndique le gain du signal Laugmentation de lintensiteacute dun signal est libelleacutee en deacutecibel (dB) Le paramegravetre peut ecirctre seacutelectionneacute de -8000dB agrave +2000dB avec des pas de 001dB Une augmentation de 6dB est eacutegale approximativement au redoublement agrave leacutechelle lineacuteaire du niveau du signal sous tensionAvec un gain supeacuterieur agrave 0dB le signal est amplifieacute tandis quavec un gain infeacuterieur agrave 0dB le signal est atteacutenueacute
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
49
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
50
c) DELAI DU SIGNAL (DELAY)Le signal audio reproduit peut ecirctre retardeacute pour permettre lalignement acoustique Cela compense les diffeacuterentes positions des diffuseurs pendant linstallation et la reproduction sonore Il se libelle en mS Le paramegravetre peut ecirctre seacutelectionneacute de 00mS agrave 729mS avec un pas de 01mSPour aligner un signal audio il est possible dutiliser la formule suivante
Deacutelai = (GAPx1000)344
Deacutelai = ms (en millisecondes)GAP = distance du diffuseur du point de reacutefeacuterence (en megravetres)Vitesse du son = 344ms
d) MUTEChaque canal peut ecirctre placeacute en mute La mecircme commande peut ecirctre activeacutee dans la fenecirctre du menu meters NB Le mute geacuteneacuteral a la plus haute prioriteacute par rapport aux mutes de chaque canal
e) PhasePermet la rotation de phase de 180deg par rapport au signal entrantCette rotation permet loptimisation surtout des basses freacutequences dans les installations complexes
f) EGALISATIONCette commande ouvre la fenecirctre du menu deacutegalisation de chaque canal Elle sert surtout pour corriger une ou plusieurs freacutequences qui doivent ecirctre atteacutenueacutees ou augmenteacutees
M M
LAC26N gegravere 12 filtres par canal dentreacutee et sortie avec trois types de configurations diffeacuterentes - Leacutegaliseur PEQ (peaking equalizer) est ideacuteal pour identifier isoler et
corriger une seule plage de freacutequences bien deacutetermineacutee Toutes les freacutequences passent mais il augmente ou diminue uniquement celles autour de la freacutequence centrale pour une bande preacutecise et un gain deacutefini
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessus de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessous de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
f Numeacuterotation des 12 filtres disponibles pour cette entreacutee ou cette sortie1
f Le type de filtre est afficheacute 2
Dis Deacutesactiveacute (absent)
PEQ Peaking equlizer
Sh H Filtre high-shelf
Sh L Filtre high-shelf
Exemples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
REMARQUELe paramegravetre Bw deacutetermine le champ de freacutequences adjacent agrave la freacutequence configureacutee ougrave est activeacute le filtre Plus la valeur Bw est eacuteleveacutee plus vaste est le champ de freacutequences (1Bw=1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONCette commande ouvre la fenecirctre du menu de compression de chaque canal
g1) TresholdIdentifie le seuil ougrave commence le rapport de compression La valeur de base 11
g2) RatioIndique le rapport de conversion entre le signal entrant et le signal sortant
g3) Post Gain Attach Release HoldCes donneacutees deacutependent du rapport de conversion que lon veut obtenir - Post Gain est le gain de sortie- Attack est le temps dattaque - Release est le temps de relacircchement- Hold est le temps de maintien
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
52
DESCRIPTION DE LA FENETRE MENU Preset
Cette fenecirctre permet de meacutemoriser jusquagrave 32 configurations dans lAC26NLe fabricant fournit le systegraveme avec un programme configureacute et enregistreacute en position 0 et non susceptible deacutecrasement
032 Elle indique lemplacement de sauvetage de la configurationCe numeacutero apparaicirct dans la fenecirctre Meters en position (g) A tout moment le programme utiliseacute peut ecirctre afficheacute par lutilisateur
Empty Preset Cest le nom qui est associeacute au numeacutero de lemplacement quand aucune configuration (vide) nest enregistreacutee
Local preset Local preset est le nom qui est associeacute au numeacutero de lemplacement quand on enregistre une configuration NB = Il est possible denregistrer une configuration avec lenom souhaiteacute de 16 lettres tout au plus agrave condition que lonutilise linterface via lordinateur
Le nom du programme assigneacute est indiqueacutePour toucher agrave lapplication 3 choix soffrent agrave vous
Save Le programme est enregistreacute en meacutemoire de lAC26N
Del Le programme est effaceacute
Load Le programme est chargeacute et precirct agrave lemploi
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
51
DESCRIPTION DE LA FENETRE MENU X-Over
Cette fenecirctre permet de seacutelectionner un filtre passe bas un filtre passe haut ou par la combinaison des deux de creacuteer un filtre passe bande pour chaque sortieLe filtre actif est un Linkwitz-Riley qui permet de seacutelectionner la pente de 12dBoct 24dBoct ou 48dBoct et sa freacutequence de coupure
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) CANAUX DE SORTIE
Les connecteurs de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) FILTRE CROSSOVERSeacutelectionner le filtre selon les besoins Il est possible de seacutelectionner
Dis Aucun filtre activeacute
HP Filtre passe-haut laisse passer uniquement la partie de signal audio supeacuterieure agrave la freacutequence de coupure
LP Filtre passe-bas laisse passer uniquement la partie de signal audio infeacuterieure agrave la freacutequence de coupure
Configuration du filtre Passe-haut Passe-bas
Rien Dis Dis
Passe-haut HP Dis
Passe-bas Dis LP
Passe-bande HP LP
12dBoct
24dBoct
Hz
dB
Ga
in 48dBoct
12dBoct
24dBoct
Hz
dB
Ga
in
48dBoct
c) PENTE DATTENUATIONSeacutelectionner la pente datteacutenuation du signal audio en fonction de la diminution que lon veut obtenir Plus la pente datteacutenuation est eacuteleveacutee agrave eacutegaliteacute de freacutequence de coupure plus eacuteleveacutee sera la seacutelection du signal Il est possible de seacutelectionner
12 correspond agrave 12dboct
24 correspond agrave 24dboct
48 correspond agrave 48dboct
d) FREQUENCE DE COUPUREElle permet de reacutegler la freacutequence de passage des freacutequences infeacuterieures (filtre passe-bas) ou des freacutequences supeacuterieures (filtre passe-haut) uniquementLe choix de la coupure deacutepend de la reproduction que lon veut obtenirLuniteacute de mesure utiliseacutee est lHz
Hz
Hz
dB
dB
Ga
in
f0
f0
0dB0dB
0dB
-6dB
freacutequence
freacutequence
freacutequence
freacutequence
Ga
in
f0
0dB
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
53
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
54
DESCRIPTION DE LA FENETRE MENU Matrix
Elle permet de seacutelectionner le signal entrant agrave utiliser comme source pour chaque sortie
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) CANAUX DE SORTIEIdentification du canal sortant agrave reacutegler
b) IDENTIFICATIONS DES ENTREESSeacutelectionner le type de signal agrave associer agrave chaque sortie en fonction des besoins Il est possible de seacutelectionner
In A Le signal entrant A est associeacute
In B Le signal entrant B est associeacute
In A+B La somme algeacutebrique des deux signaux entrants A et B est associeacutee
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
DESCRIPTION DE LA FENETRE MENU Option
Permet dafficher les reacuteglages du systegraveme comme lassignation des entreacutees et des sorties latteacutenuation le contraste de laffichage et la version du logiciel
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcCette option permet de reacutegler le type de signal audio entrant
An In =signaux audio analogiques (entreacutees ldquoArdquo et ldquoBrdquo)
Dig In =signaux audio numeacuteriques (entreacutee AESEBU)
DigOut SrcCette option permet de seacutelectionner la source audio qui sera adresseacutee sur le connecteur AESEBU OUT (sortie numeacuterique)
An In = signaux audio des entreacutees analogiques
Dig In =signaux audio sur lentreacutee numeacuterique
OUT 1-2 = signaux audio sur les sorties 1 et 2
OUT 3-4 = signaux audio sur les sorties 3 et 4
OUT 5-6 = signaux audio sur les sorties 5 et 6
Input ModePermet de configurer les entreacutees
Indip = sont indeacutependantes et autonomes Ne sont soumises agrave aucun type de lien
Linked = sont unies et fonctionnent en mode steacutereacuteo Les compresseurs les filtres les deacutelais le volume sont identiques pour les deux canaux
Atten PadIndique le mode de reacuteglage du seacutelecteur ldquo-6dBrdquo placeacute agrave larriegravere [reacutef 5] Il faut activer ce seacutelecteur quand les niveaux dentreacutee analogiques sont trop eacuteleveacutes Le seacutelecteur sactive uniquement par le bouton Dans le menu il sagit dune simple visualisation
0dB = seacutelecteur non activeacute Les signaux dentreacutee sont identiques agrave la source entrante
-6dB = seacutelecteur activeacute Les signaux entrants sont atteacutenueacutes de -6dB par le processeur interne
ContrastIl permet de reacutegler le contraste de laffichage agrave cristaux liquides pour compenser la diffeacuterence de luminositeacute avec le lieu dinstallation Une plus grande clarteacute de laffichage permet de naviguer convenablement et rapidement dans les menusLe reacuteglage agrave la sortie de lusine du fabricant est de 60
10 plus clair 60 plus fonceacute 100
Fw VersIndique la version du logiciel du processeur
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
55
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
56
DONNES TECHINIQUES
PERFORMANCES AUDIOReacuteponse en freacutequence +- 01dB (20 to 30kHz)Plage dynamique 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsion 0002 (1kHz +4dBu)
PERFORMANCES AUDIO NUMERIQUES Processeur DSP 2856-bit Freacutequence de traitement des donneacutees 48KHzConvertisseurs analogiques 24-bit BURR BROWNDeacutelai de propagation 15msMeacutemorisations des configurations 32 preset
CONTROLES Affichage LCD graficoBoutonsCommandes ESC - MENU - FUNCTIONS SELECTION
ENTERENTREESSORTIESEntreacutee analogique ndeg2 x XLR (3 broches femelle)
Impeacutedance dentreacutee gt10KOhmNiveau maximum +21dBu senza PAD
+27dBu con PADSortie analogique ndeg6 x XLR (3 broches macircle )
Impeacutedance de sortie 50OhmNiveau maximum +21dBuType Balanceacute
Entreacutee numeacuterique ndeg1x XLR (3 broches femelle)Type SPDIF-AESEBU (AES3)
Sortie numeacuterique ndeg1x XLR (3 broches macircle )Type conforme agrave la norme de lentreacutee
EntreacuteesSortie Rdnet ndeg2 x XLR RJ45 (cacircble CAT 5)USB Type B
PARAMETRES DE CONTROLE DU SONGain -80dB a +20dB eacutetape 01dBDeacutelai Entreacutee 0 a 729mS eacutetape 01 mS
Sortie 0 a 340mS eacutetape 01mSRotation de phase 0deg - 180deg
COMPRESSIONSeuil -80dB a +20dB eacutetape 01dBRapport 11 a Inf1 eacutetape 001Gain agrave la sortie 0dB a 40dB eacutetape 01dBTemps dattaque 1mS a 1000mS eacutetape 01mSTemps de relacircchement 1mS a 1000mS eacutetape 01mSTemps de maintien 1mS a 1000mS eacutetape 01mS
EGALISEURS12 eacutegaliseurs pour chaque entreacutee et sortieType PEQ (parameacutetrique) Hi-shelf Lo-sheft
Freacutequence 20Hz a 20KHz eacutetape 1HzGain -30dB a +15dB eacutetape 001dBBande 005dB a 2dB eacutetape 001dB (uniquement pour PEQ)
FILTRES CROSSOVERFiltre Linkwitz Riley
Type HF high-shelfLF low-shelf
Pente 12dBoct - 24dBoct - 48dBoctFreacutequence de coupure 5Hz a 20KHz eacutetape 1Hz
ALIMENTATION Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)POIDS 19Kg
Remarques Speacutecifications sujettes agrave modifications sans preacuteavis
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
2 VIE ATTIVO2 WAY ACTIVE
3 VIE PASSIVO3 WAY PASSIVE
L
L
A
A
HIGH L
MID L
LOW HIGHMID RHIGHMID L
LOW L
HIGH R
MID R
LOW R
R
R
B
B
1
1
2
2
3
3
456
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
Menu Matrix configurationMatrix
57 58
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
EROUIG ATRIX TNM
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
OU
TP
UT
1
OU
TP
UT
2
OU
TP
UT
3
OU
TP
UT
4
OU
TP
UT
5
OU
TP
UT
6
AE
S-E
BU
OU
TP
UT
INP
UT
A
AE
S-E
BU
INP
UT
INP
UT
B
D D D D D D
D D
A A A A A A
A SA
MP
LE
RA
TE
CO
NV
A
LIN
KA
BL
E
SC
HE
MA
A B
LO
CC
HI -
BL
OC
K D
IAG
RA
MB
LO
CK
SC
HA
LT
BIL
D -
SC
HE
MA
S F
ON
CT
ION
NE
LS
LINE ARRAY SUB MONO ATTIVO
LINE ARRAY SUB MONO ACTIVEINGRESSI - INPUT
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
L
L
L
A
A
A
AESEBU IN
AESEBU IN
AESEBU IN
AESEBU OUT
AESEBU IN
AESEBU IN
AESEBU OUT
R
R
R
LR
B
B
B
123456
HIGHMID L
HIGHMID L HIGHMID R
HIGHMID R
LOW L LOW R
LAYER
DISPLAY MEMORY
FADER MODE
LAYER
DISPLAY MEMORY
FADER MODE
Ingresso ANALOGICO
ANALOG Input
Collegamento in cascata
Link connections
Ingresso DIGITALE
DIGITAL inputA B
BALANCED AUDIO INPUTS
-6dB
PUSH PUSH
IN OUT
AES EBUPUSH
Oppure
or
Oppure
or
Menu Option configurationOption
Menu Option configurationOption Menu Option configurationOption
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type Analog
AES out An In
Input type Analog
AES out An In
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
59 60
InA-B Src Dig InInA-B Src Dig InInA-B Src An InInA-B Src An In
frequenzaHz
dB
Gu
ad
ag
no
60 200 2800
0dB0dB
-6dB
Esempio di un sistema a 3-vie
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
Out 1 Out 2 Out 3
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Esempio di un sistema a 3-vie
61 62
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
26NAC 26NAC
R TE
DO
R
MO LEU O R CE S
E O TR L A
S O
O C ND I P
P hsuernE t
o su cti nF nel rS e tc o
E CSME UN
IGCHTE OL SN EOBd
ocaL l
M
0
484
467
430
44
31
75
12
7
DIMENSIONI DIMENSIONSABMESSUNGEN DIMENSIONS
LAC26N gegravere 12 filtres par canal dentreacutee et sortie avec trois types de configurations diffeacuterentes - Leacutegaliseur PEQ (peaking equalizer) est ideacuteal pour identifier isoler et
corriger une seule plage de freacutequences bien deacutetermineacutee Toutes les freacutequences passent mais il augmente ou diminue uniquement celles autour de la freacutequence centrale pour une bande preacutecise et un gain deacutefini
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessus de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
- Leacutegaliseur high-self laisse passer toutes les freacutequences mais il augmente ou atteacutenue les freacutequences au-dessous de la freacutequence de coupure seacutelectionneacutee pour le gain speacutecifieacute
f Numeacuterotation des 12 filtres disponibles pour cette entreacutee ou cette sortie1
f Le type de filtre est afficheacute 2
Dis Deacutesactiveacute (absent)
PEQ Peaking equlizer
Sh H Filtre high-shelf
Sh L Filtre high-shelf
Exemples PEQ Peaking equlizer
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -900dB 100
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
Type Freq Gain Bw
PEQ 1000Hz -1200dB 100
PEQ 1000Hz -1200dB 500
REMARQUELe paramegravetre Bw deacutetermine le champ de freacutequences adjacent agrave la freacutequence configureacutee ougrave est activeacute le filtre Plus la valeur Bw est eacuteleveacutee plus vaste est le champ de freacutequences (1Bw=1 octave)
Hz
Hz
dB
dB
0dB
0dB
0dB
0dB
-12dB
-12dB
-9dB
-9dB
1KHz
1KHz
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
Type Freq Gain Bw
1 ----Hz ----dB ---
2 Dis ----Hz ----dB ---
3 Dis ----Hz ----dB ---
Dis
f1 f2
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Type Freq Gain
Sh H 8000Hz -1000dB
Sh H 8000Hz +1000dB
Sh H Filtro high-shelf
Hz
dB
0dB
-10dB
+10dB
8KHz
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Type Freq Gain
Sh L 200Hz -600dB
Sh L 200Hz +600dB
Sh L Filtro low-shelf
Hz
dB
0dB
-6dB
+6dB
200Hz
g) COMPRESSIONCette commande ouvre la fenecirctre du menu de compression de chaque canal
g1) TresholdIdentifie le seuil ougrave commence le rapport de compression La valeur de base 11
g2) RatioIndique le rapport de conversion entre le signal entrant et le signal sortant
g3) Post Gain Attach Release HoldCes donneacutees deacutependent du rapport de conversion que lon veut obtenir - Post Gain est le gain de sortie- Attack est le temps dattaque - Release est le temps de relacircchement- Hold est le temps de maintien
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
Treshold -2000dB
Ratio 1001
Post Gain +000dB
Attack 200mS
Release 1000mS
Hold 00mS
g1
g3
g2
dB
Input
dB
output
-20dB
20dB
1121
RATIO
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
52
DESCRIPTION DE LA FENETRE MENU Preset
Cette fenecirctre permet de meacutemoriser jusquagrave 32 configurations dans lAC26NLe fabricant fournit le systegraveme avec un programme configureacute et enregistreacute en position 0 et non susceptible deacutecrasement
032 Elle indique lemplacement de sauvetage de la configurationCe numeacutero apparaicirct dans la fenecirctre Meters en position (g) A tout moment le programme utiliseacute peut ecirctre afficheacute par lutilisateur
Empty Preset Cest le nom qui est associeacute au numeacutero de lemplacement quand aucune configuration (vide) nest enregistreacutee
Local preset Local preset est le nom qui est associeacute au numeacutero de lemplacement quand on enregistre une configuration NB = Il est possible denregistrer une configuration avec lenom souhaiteacute de 16 lettres tout au plus agrave condition que lonutilise linterface via lordinateur
Le nom du programme assigneacute est indiqueacutePour toucher agrave lapplication 3 choix soffrent agrave vous
Save Le programme est enregistreacute en meacutemoire de lAC26N
Del Le programme est effaceacute
Load Le programme est chargeacute et precirct agrave lemploi
Ch ob
X-Over
Option
Ch ob
X-Over
Option
Meters
Matrix
Preset
Meters
Matrix
Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
0 Flat Preset
1 Empty Preset
2 Empty Preset
3 Empty Preset
4 Local Preset4 Local Preset
Save LoadDel Save LoadDel
51
DESCRIPTION DE LA FENETRE MENU X-Over
Cette fenecirctre permet de seacutelectionner un filtre passe bas un filtre passe haut ou par la combinaison des deux de creacuteer un filtre passe bande pour chaque sortieLe filtre actif est un Linkwitz-Riley qui permet de seacutelectionner la pente de 12dBoct 24dBoct ou 48dBoct et sa freacutequence de coupure
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) CANAUX DE SORTIE
Les connecteurs de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) FILTRE CROSSOVERSeacutelectionner le filtre selon les besoins Il est possible de seacutelectionner
Dis Aucun filtre activeacute
HP Filtre passe-haut laisse passer uniquement la partie de signal audio supeacuterieure agrave la freacutequence de coupure
LP Filtre passe-bas laisse passer uniquement la partie de signal audio infeacuterieure agrave la freacutequence de coupure
Configuration du filtre Passe-haut Passe-bas
Rien Dis Dis
Passe-haut HP Dis
Passe-bas Dis LP
Passe-bande HP LP
12dBoct
24dBoct
Hz
dB
Ga
in 48dBoct
12dBoct
24dBoct
Hz
dB
Ga
in
48dBoct
c) PENTE DATTENUATIONSeacutelectionner la pente datteacutenuation du signal audio en fonction de la diminution que lon veut obtenir Plus la pente datteacutenuation est eacuteleveacutee agrave eacutegaliteacute de freacutequence de coupure plus eacuteleveacutee sera la seacutelection du signal Il est possible de seacutelectionner
12 correspond agrave 12dboct
24 correspond agrave 24dboct
48 correspond agrave 48dboct
d) FREQUENCE DE COUPUREElle permet de reacutegler la freacutequence de passage des freacutequences infeacuterieures (filtre passe-bas) ou des freacutequences supeacuterieures (filtre passe-haut) uniquementLe choix de la coupure deacutepend de la reproduction que lon veut obtenirLuniteacute de mesure utiliseacutee est lHz
Hz
Hz
dB
dB
Ga
in
f0
f0
0dB0dB
0dB
-6dB
freacutequence
freacutequence
freacutequence
freacutequence
Ga
in
f0
0dB
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
53
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
54
DESCRIPTION DE LA FENETRE MENU Matrix
Elle permet de seacutelectionner le signal entrant agrave utiliser comme source pour chaque sortie
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) CANAUX DE SORTIEIdentification du canal sortant agrave reacutegler
b) IDENTIFICATIONS DES ENTREESSeacutelectionner le type de signal agrave associer agrave chaque sortie en fonction des besoins Il est possible de seacutelectionner
In A Le signal entrant A est associeacute
In B Le signal entrant B est associeacute
In A+B La somme algeacutebrique des deux signaux entrants A et B est associeacutee
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
DESCRIPTION DE LA FENETRE MENU Option
Permet dafficher les reacuteglages du systegraveme comme lassignation des entreacutees et des sorties latteacutenuation le contraste de laffichage et la version du logiciel
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcCette option permet de reacutegler le type de signal audio entrant
An In =signaux audio analogiques (entreacutees ldquoArdquo et ldquoBrdquo)
Dig In =signaux audio numeacuteriques (entreacutee AESEBU)
DigOut SrcCette option permet de seacutelectionner la source audio qui sera adresseacutee sur le connecteur AESEBU OUT (sortie numeacuterique)
An In = signaux audio des entreacutees analogiques
Dig In =signaux audio sur lentreacutee numeacuterique
OUT 1-2 = signaux audio sur les sorties 1 et 2
OUT 3-4 = signaux audio sur les sorties 3 et 4
OUT 5-6 = signaux audio sur les sorties 5 et 6
Input ModePermet de configurer les entreacutees
Indip = sont indeacutependantes et autonomes Ne sont soumises agrave aucun type de lien
Linked = sont unies et fonctionnent en mode steacutereacuteo Les compresseurs les filtres les deacutelais le volume sont identiques pour les deux canaux
Atten PadIndique le mode de reacuteglage du seacutelecteur ldquo-6dBrdquo placeacute agrave larriegravere [reacutef 5] Il faut activer ce seacutelecteur quand les niveaux dentreacutee analogiques sont trop eacuteleveacutes Le seacutelecteur sactive uniquement par le bouton Dans le menu il sagit dune simple visualisation
0dB = seacutelecteur non activeacute Les signaux dentreacutee sont identiques agrave la source entrante
-6dB = seacutelecteur activeacute Les signaux entrants sont atteacutenueacutes de -6dB par le processeur interne
ContrastIl permet de reacutegler le contraste de laffichage agrave cristaux liquides pour compenser la diffeacuterence de luminositeacute avec le lieu dinstallation Une plus grande clarteacute de laffichage permet de naviguer convenablement et rapidement dans les menusLe reacuteglage agrave la sortie de lusine du fabricant est de 60
10 plus clair 60 plus fonceacute 100
Fw VersIndique la version du logiciel du processeur
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
55
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
56
DONNES TECHINIQUES
PERFORMANCES AUDIOReacuteponse en freacutequence +- 01dB (20 to 30kHz)Plage dynamique 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsion 0002 (1kHz +4dBu)
PERFORMANCES AUDIO NUMERIQUES Processeur DSP 2856-bit Freacutequence de traitement des donneacutees 48KHzConvertisseurs analogiques 24-bit BURR BROWNDeacutelai de propagation 15msMeacutemorisations des configurations 32 preset
CONTROLES Affichage LCD graficoBoutonsCommandes ESC - MENU - FUNCTIONS SELECTION
ENTERENTREESSORTIESEntreacutee analogique ndeg2 x XLR (3 broches femelle)
Impeacutedance dentreacutee gt10KOhmNiveau maximum +21dBu senza PAD
+27dBu con PADSortie analogique ndeg6 x XLR (3 broches macircle )
Impeacutedance de sortie 50OhmNiveau maximum +21dBuType Balanceacute
Entreacutee numeacuterique ndeg1x XLR (3 broches femelle)Type SPDIF-AESEBU (AES3)
Sortie numeacuterique ndeg1x XLR (3 broches macircle )Type conforme agrave la norme de lentreacutee
EntreacuteesSortie Rdnet ndeg2 x XLR RJ45 (cacircble CAT 5)USB Type B
PARAMETRES DE CONTROLE DU SONGain -80dB a +20dB eacutetape 01dBDeacutelai Entreacutee 0 a 729mS eacutetape 01 mS
Sortie 0 a 340mS eacutetape 01mSRotation de phase 0deg - 180deg
COMPRESSIONSeuil -80dB a +20dB eacutetape 01dBRapport 11 a Inf1 eacutetape 001Gain agrave la sortie 0dB a 40dB eacutetape 01dBTemps dattaque 1mS a 1000mS eacutetape 01mSTemps de relacircchement 1mS a 1000mS eacutetape 01mSTemps de maintien 1mS a 1000mS eacutetape 01mS
EGALISEURS12 eacutegaliseurs pour chaque entreacutee et sortieType PEQ (parameacutetrique) Hi-shelf Lo-sheft
Freacutequence 20Hz a 20KHz eacutetape 1HzGain -30dB a +15dB eacutetape 001dBBande 005dB a 2dB eacutetape 001dB (uniquement pour PEQ)
FILTRES CROSSOVERFiltre Linkwitz Riley
Type HF high-shelfLF low-shelf
Pente 12dBoct - 24dBoct - 48dBoctFreacutequence de coupure 5Hz a 20KHz eacutetape 1Hz
ALIMENTATION Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)POIDS 19Kg
Remarques Speacutecifications sujettes agrave modifications sans preacuteavis
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
2 VIE ATTIVO2 WAY ACTIVE
3 VIE PASSIVO3 WAY PASSIVE
L
L
A
A
HIGH L
MID L
LOW HIGHMID RHIGHMID L
LOW L
HIGH R
MID R
LOW R
R
R
B
B
1
1
2
2
3
3
456
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
Menu Matrix configurationMatrix
57 58
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
EROUIG ATRIX TNM
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
OU
TP
UT
1
OU
TP
UT
2
OU
TP
UT
3
OU
TP
UT
4
OU
TP
UT
5
OU
TP
UT
6
AE
S-E
BU
OU
TP
UT
INP
UT
A
AE
S-E
BU
INP
UT
INP
UT
B
D D D D D D
D D
A A A A A A
A SA
MP
LE
RA
TE
CO
NV
A
LIN
KA
BL
E
SC
HE
MA
A B
LO
CC
HI -
BL
OC
K D
IAG
RA
MB
LO
CK
SC
HA
LT
BIL
D -
SC
HE
MA
S F
ON
CT
ION
NE
LS
LINE ARRAY SUB MONO ATTIVO
LINE ARRAY SUB MONO ACTIVEINGRESSI - INPUT
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
L
L
L
A
A
A
AESEBU IN
AESEBU IN
AESEBU IN
AESEBU OUT
AESEBU IN
AESEBU IN
AESEBU OUT
R
R
R
LR
B
B
B
123456
HIGHMID L
HIGHMID L HIGHMID R
HIGHMID R
LOW L LOW R
LAYER
DISPLAY MEMORY
FADER MODE
LAYER
DISPLAY MEMORY
FADER MODE
Ingresso ANALOGICO
ANALOG Input
Collegamento in cascata
Link connections
Ingresso DIGITALE
DIGITAL inputA B
BALANCED AUDIO INPUTS
-6dB
PUSH PUSH
IN OUT
AES EBUPUSH
Oppure
or
Oppure
or
Menu Option configurationOption
Menu Option configurationOption Menu Option configurationOption
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type Analog
AES out An In
Input type Analog
AES out An In
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
59 60
InA-B Src Dig InInA-B Src Dig InInA-B Src An InInA-B Src An In
frequenzaHz
dB
Gu
ad
ag
no
60 200 2800
0dB0dB
-6dB
Esempio di un sistema a 3-vie
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
Out 1 Out 2 Out 3
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Esempio di un sistema a 3-vie
61 62
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
26NAC 26NAC
R TE
DO
R
MO LEU O R CE S
E O TR L A
S O
O C ND I P
P hsuernE t
o su cti nF nel rS e tc o
E CSME UN
IGCHTE OL SN EOBd
ocaL l
M
0
484
467
430
44
31
75
12
7
DIMENSIONI DIMENSIONSABMESSUNGEN DIMENSIONS
DESCRIPTION DE LA FENETRE MENU X-Over
Cette fenecirctre permet de seacutelectionner un filtre passe bas un filtre passe haut ou par la combinaison des deux de creacuteer un filtre passe bande pour chaque sortieLe filtre actif est un Linkwitz-Riley qui permet de seacutelectionner la pente de 12dBoct 24dBoct ou 48dBoct et sa freacutequence de coupure
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Type Freq Type Freq
1 HP12 106Hz Dis --Hz
2 HP24 329Hz LP24 732Hz
3 HP48 216HZ LP48 74324Hz
Type Freq Type Freq
1
2
3
HP12 106Hz Dis --Hz
HP24 329Hz LP24 732Hz
HP48 216HZ LP48 74324Hz
a b bc cd da) CANAUX DE SORTIE
Les connecteurs de sortie sont identifieacutes en utilisant les mecircmes indications figurant sur la seacuterigraphie agrave larriegravere du dispositif
b) FILTRE CROSSOVERSeacutelectionner le filtre selon les besoins Il est possible de seacutelectionner
Dis Aucun filtre activeacute
HP Filtre passe-haut laisse passer uniquement la partie de signal audio supeacuterieure agrave la freacutequence de coupure
LP Filtre passe-bas laisse passer uniquement la partie de signal audio infeacuterieure agrave la freacutequence de coupure
Configuration du filtre Passe-haut Passe-bas
Rien Dis Dis
Passe-haut HP Dis
Passe-bas Dis LP
Passe-bande HP LP
12dBoct
24dBoct
Hz
dB
Ga
in 48dBoct
12dBoct
24dBoct
Hz
dB
Ga
in
48dBoct
c) PENTE DATTENUATIONSeacutelectionner la pente datteacutenuation du signal audio en fonction de la diminution que lon veut obtenir Plus la pente datteacutenuation est eacuteleveacutee agrave eacutegaliteacute de freacutequence de coupure plus eacuteleveacutee sera la seacutelection du signal Il est possible de seacutelectionner
12 correspond agrave 12dboct
24 correspond agrave 24dboct
48 correspond agrave 48dboct
d) FREQUENCE DE COUPUREElle permet de reacutegler la freacutequence de passage des freacutequences infeacuterieures (filtre passe-bas) ou des freacutequences supeacuterieures (filtre passe-haut) uniquementLe choix de la coupure deacutepend de la reproduction que lon veut obtenirLuniteacute de mesure utiliseacutee est lHz
Hz
Hz
dB
dB
Ga
in
f0
f0
0dB0dB
0dB
-6dB
freacutequence
freacutequence
freacutequence
freacutequence
Ga
in
f0
0dB
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
53
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
54
DESCRIPTION DE LA FENETRE MENU Matrix
Elle permet de seacutelectionner le signal entrant agrave utiliser comme source pour chaque sortie
Ch ob
X-Over
Option
Ch ob
X-Over
Option
a) CANAUX DE SORTIEIdentification du canal sortant agrave reacutegler
b) IDENTIFICATIONS DES ENTREESSeacutelectionner le type de signal agrave associer agrave chaque sortie en fonction des besoins Il est possible de seacutelectionner
In A Le signal entrant A est associeacute
In B Le signal entrant B est associeacute
In A+B La somme algeacutebrique des deux signaux entrants A et B est associeacutee
a b
Meters
Preset
Matrix
Meters
Preset
Matrix
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
Channel Source Channel Source
Out 1 Out 4 In B
Out 2 In B Out 5 In A+B
Out 3 In A+B Out 6 In B
In A
DESCRIPTION DE LA FENETRE MENU Option
Permet dafficher les reacuteglages du systegraveme comme lassignation des entreacutees et des sorties latteacutenuation le contraste de laffichage et la version du logiciel
Ch ob
X-Over
Option
Ch ob
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
InA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An InInA-B Src
DigOut Src An In
Input Link Indip
Atten Pad 0dB
An In
Contrast 60
Fw Vers v0711
Contrast 60
Fw Vers v0711InA-B SrcCette option permet de reacutegler le type de signal audio entrant
An In =signaux audio analogiques (entreacutees ldquoArdquo et ldquoBrdquo)
Dig In =signaux audio numeacuteriques (entreacutee AESEBU)
DigOut SrcCette option permet de seacutelectionner la source audio qui sera adresseacutee sur le connecteur AESEBU OUT (sortie numeacuterique)
An In = signaux audio des entreacutees analogiques
Dig In =signaux audio sur lentreacutee numeacuterique
OUT 1-2 = signaux audio sur les sorties 1 et 2
OUT 3-4 = signaux audio sur les sorties 3 et 4
OUT 5-6 = signaux audio sur les sorties 5 et 6
Input ModePermet de configurer les entreacutees
Indip = sont indeacutependantes et autonomes Ne sont soumises agrave aucun type de lien
Linked = sont unies et fonctionnent en mode steacutereacuteo Les compresseurs les filtres les deacutelais le volume sont identiques pour les deux canaux
Atten PadIndique le mode de reacuteglage du seacutelecteur ldquo-6dBrdquo placeacute agrave larriegravere [reacutef 5] Il faut activer ce seacutelecteur quand les niveaux dentreacutee analogiques sont trop eacuteleveacutes Le seacutelecteur sactive uniquement par le bouton Dans le menu il sagit dune simple visualisation
0dB = seacutelecteur non activeacute Les signaux dentreacutee sont identiques agrave la source entrante
-6dB = seacutelecteur activeacute Les signaux entrants sont atteacutenueacutes de -6dB par le processeur interne
ContrastIl permet de reacutegler le contraste de laffichage agrave cristaux liquides pour compenser la diffeacuterence de luminositeacute avec le lieu dinstallation Une plus grande clarteacute de laffichage permet de naviguer convenablement et rapidement dans les menusLe reacuteglage agrave la sortie de lusine du fabricant est de 60
10 plus clair 60 plus fonceacute 100
Fw VersIndique la version du logiciel du processeur
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
55
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
56
DONNES TECHINIQUES
PERFORMANCES AUDIOReacuteponse en freacutequence +- 01dB (20 to 30kHz)Plage dynamique 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsion 0002 (1kHz +4dBu)
PERFORMANCES AUDIO NUMERIQUES Processeur DSP 2856-bit Freacutequence de traitement des donneacutees 48KHzConvertisseurs analogiques 24-bit BURR BROWNDeacutelai de propagation 15msMeacutemorisations des configurations 32 preset
CONTROLES Affichage LCD graficoBoutonsCommandes ESC - MENU - FUNCTIONS SELECTION
ENTERENTREESSORTIESEntreacutee analogique ndeg2 x XLR (3 broches femelle)
Impeacutedance dentreacutee gt10KOhmNiveau maximum +21dBu senza PAD
+27dBu con PADSortie analogique ndeg6 x XLR (3 broches macircle )
Impeacutedance de sortie 50OhmNiveau maximum +21dBuType Balanceacute
Entreacutee numeacuterique ndeg1x XLR (3 broches femelle)Type SPDIF-AESEBU (AES3)
Sortie numeacuterique ndeg1x XLR (3 broches macircle )Type conforme agrave la norme de lentreacutee
EntreacuteesSortie Rdnet ndeg2 x XLR RJ45 (cacircble CAT 5)USB Type B
PARAMETRES DE CONTROLE DU SONGain -80dB a +20dB eacutetape 01dBDeacutelai Entreacutee 0 a 729mS eacutetape 01 mS
Sortie 0 a 340mS eacutetape 01mSRotation de phase 0deg - 180deg
COMPRESSIONSeuil -80dB a +20dB eacutetape 01dBRapport 11 a Inf1 eacutetape 001Gain agrave la sortie 0dB a 40dB eacutetape 01dBTemps dattaque 1mS a 1000mS eacutetape 01mSTemps de relacircchement 1mS a 1000mS eacutetape 01mSTemps de maintien 1mS a 1000mS eacutetape 01mS
EGALISEURS12 eacutegaliseurs pour chaque entreacutee et sortieType PEQ (parameacutetrique) Hi-shelf Lo-sheft
Freacutequence 20Hz a 20KHz eacutetape 1HzGain -30dB a +15dB eacutetape 001dBBande 005dB a 2dB eacutetape 001dB (uniquement pour PEQ)
FILTRES CROSSOVERFiltre Linkwitz Riley
Type HF high-shelfLF low-shelf
Pente 12dBoct - 24dBoct - 48dBoctFreacutequence de coupure 5Hz a 20KHz eacutetape 1Hz
ALIMENTATION Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)POIDS 19Kg
Remarques Speacutecifications sujettes agrave modifications sans preacuteavis
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
2 VIE ATTIVO2 WAY ACTIVE
3 VIE PASSIVO3 WAY PASSIVE
L
L
A
A
HIGH L
MID L
LOW HIGHMID RHIGHMID L
LOW L
HIGH R
MID R
LOW R
R
R
B
B
1
1
2
2
3
3
456
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
Menu Matrix configurationMatrix
57 58
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
EROUIG ATRIX TNM
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
OU
TP
UT
1
OU
TP
UT
2
OU
TP
UT
3
OU
TP
UT
4
OU
TP
UT
5
OU
TP
UT
6
AE
S-E
BU
OU
TP
UT
INP
UT
A
AE
S-E
BU
INP
UT
INP
UT
B
D D D D D D
D D
A A A A A A
A SA
MP
LE
RA
TE
CO
NV
A
LIN
KA
BL
E
SC
HE
MA
A B
LO
CC
HI -
BL
OC
K D
IAG
RA
MB
LO
CK
SC
HA
LT
BIL
D -
SC
HE
MA
S F
ON
CT
ION
NE
LS
LINE ARRAY SUB MONO ATTIVO
LINE ARRAY SUB MONO ACTIVEINGRESSI - INPUT
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
L
L
L
A
A
A
AESEBU IN
AESEBU IN
AESEBU IN
AESEBU OUT
AESEBU IN
AESEBU IN
AESEBU OUT
R
R
R
LR
B
B
B
123456
HIGHMID L
HIGHMID L HIGHMID R
HIGHMID R
LOW L LOW R
LAYER
DISPLAY MEMORY
FADER MODE
LAYER
DISPLAY MEMORY
FADER MODE
Ingresso ANALOGICO
ANALOG Input
Collegamento in cascata
Link connections
Ingresso DIGITALE
DIGITAL inputA B
BALANCED AUDIO INPUTS
-6dB
PUSH PUSH
IN OUT
AES EBUPUSH
Oppure
or
Oppure
or
Menu Option configurationOption
Menu Option configurationOption Menu Option configurationOption
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type Analog
AES out An In
Input type Analog
AES out An In
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
59 60
InA-B Src Dig InInA-B Src Dig InInA-B Src An InInA-B Src An In
frequenzaHz
dB
Gu
ad
ag
no
60 200 2800
0dB0dB
-6dB
Esempio di un sistema a 3-vie
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
Out 1 Out 2 Out 3
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Esempio di un sistema a 3-vie
61 62
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
26NAC 26NAC
R TE
DO
R
MO LEU O R CE S
E O TR L A
S O
O C ND I P
P hsuernE t
o su cti nF nel rS e tc o
E CSME UN
IGCHTE OL SN EOBd
ocaL l
M
0
484
467
430
44
31
75
12
7
DIMENSIONI DIMENSIONSABMESSUNGEN DIMENSIONS
Atten PadIndique le mode de reacuteglage du seacutelecteur ldquo-6dBrdquo placeacute agrave larriegravere [reacutef 5] Il faut activer ce seacutelecteur quand les niveaux dentreacutee analogiques sont trop eacuteleveacutes Le seacutelecteur sactive uniquement par le bouton Dans le menu il sagit dune simple visualisation
0dB = seacutelecteur non activeacute Les signaux dentreacutee sont identiques agrave la source entrante
-6dB = seacutelecteur activeacute Les signaux entrants sont atteacutenueacutes de -6dB par le processeur interne
ContrastIl permet de reacutegler le contraste de laffichage agrave cristaux liquides pour compenser la diffeacuterence de luminositeacute avec le lieu dinstallation Une plus grande clarteacute de laffichage permet de naviguer convenablement et rapidement dans les menusLe reacuteglage agrave la sortie de lusine du fabricant est de 60
10 plus clair 60 plus fonceacute 100
Fw VersIndique la version du logiciel du processeur
Fra
nccedil
ais
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
55
Ca
rac
teri
sti
qu
es
te
ch
niq
ue
sC
ara
cte
ris
tiq
ue
s t
ec
hn
iqu
es
Fra
nccedil
ais
56
DONNES TECHINIQUES
PERFORMANCES AUDIOReacuteponse en freacutequence +- 01dB (20 to 30kHz)Plage dynamique 116dB typCMMR gt 60dB (50 to 10kHz)Crosstalk lt -100dBDistorsion 0002 (1kHz +4dBu)
PERFORMANCES AUDIO NUMERIQUES Processeur DSP 2856-bit Freacutequence de traitement des donneacutees 48KHzConvertisseurs analogiques 24-bit BURR BROWNDeacutelai de propagation 15msMeacutemorisations des configurations 32 preset
CONTROLES Affichage LCD graficoBoutonsCommandes ESC - MENU - FUNCTIONS SELECTION
ENTERENTREESSORTIESEntreacutee analogique ndeg2 x XLR (3 broches femelle)
Impeacutedance dentreacutee gt10KOhmNiveau maximum +21dBu senza PAD
+27dBu con PADSortie analogique ndeg6 x XLR (3 broches macircle )
Impeacutedance de sortie 50OhmNiveau maximum +21dBuType Balanceacute
Entreacutee numeacuterique ndeg1x XLR (3 broches femelle)Type SPDIF-AESEBU (AES3)
Sortie numeacuterique ndeg1x XLR (3 broches macircle )Type conforme agrave la norme de lentreacutee
EntreacuteesSortie Rdnet ndeg2 x XLR RJ45 (cacircble CAT 5)USB Type B
PARAMETRES DE CONTROLE DU SONGain -80dB a +20dB eacutetape 01dBDeacutelai Entreacutee 0 a 729mS eacutetape 01 mS
Sortie 0 a 340mS eacutetape 01mSRotation de phase 0deg - 180deg
COMPRESSIONSeuil -80dB a +20dB eacutetape 01dBRapport 11 a Inf1 eacutetape 001Gain agrave la sortie 0dB a 40dB eacutetape 01dBTemps dattaque 1mS a 1000mS eacutetape 01mSTemps de relacircchement 1mS a 1000mS eacutetape 01mSTemps de maintien 1mS a 1000mS eacutetape 01mS
EGALISEURS12 eacutegaliseurs pour chaque entreacutee et sortieType PEQ (parameacutetrique) Hi-shelf Lo-sheft
Freacutequence 20Hz a 20KHz eacutetape 1HzGain -30dB a +15dB eacutetape 001dBBande 005dB a 2dB eacutetape 001dB (uniquement pour PEQ)
FILTRES CROSSOVERFiltre Linkwitz Riley
Type HF high-shelfLF low-shelf
Pente 12dBoct - 24dBoct - 48dBoctFreacutequence de coupure 5Hz a 20KHz eacutetape 1Hz
ALIMENTATION Full-range 100-240Vac 50-60HzDIMENSIONS 430482x43x130mm (WxHxD)POIDS 19Kg
Remarques Speacutecifications sujettes agrave modifications sans preacuteavis
EMV EinstufungEntsprechend der Norm EN 55103 ist diese Geraumlt entwickelt um inE3 (oder E2 E1) elektromagnetischen Umgebungen zu arbeiten
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
2 VIE ATTIVO2 WAY ACTIVE
3 VIE PASSIVO3 WAY PASSIVE
L
L
A
A
HIGH L
MID L
LOW HIGHMID RHIGHMID L
LOW L
HIGH R
MID R
LOW R
R
R
B
B
1
1
2
2
3
3
456
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
Menu Matrix configurationMatrix
57 58
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
EROUIG ATRIX TNM
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
OU
TP
UT
1
OU
TP
UT
2
OU
TP
UT
3
OU
TP
UT
4
OU
TP
UT
5
OU
TP
UT
6
AE
S-E
BU
OU
TP
UT
INP
UT
A
AE
S-E
BU
INP
UT
INP
UT
B
D D D D D D
D D
A A A A A A
A SA
MP
LE
RA
TE
CO
NV
A
LIN
KA
BL
E
SC
HE
MA
A B
LO
CC
HI -
BL
OC
K D
IAG
RA
MB
LO
CK
SC
HA
LT
BIL
D -
SC
HE
MA
S F
ON
CT
ION
NE
LS
LINE ARRAY SUB MONO ATTIVO
LINE ARRAY SUB MONO ACTIVEINGRESSI - INPUT
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
L
L
L
A
A
A
AESEBU IN
AESEBU IN
AESEBU IN
AESEBU OUT
AESEBU IN
AESEBU IN
AESEBU OUT
R
R
R
LR
B
B
B
123456
HIGHMID L
HIGHMID L HIGHMID R
HIGHMID R
LOW L LOW R
LAYER
DISPLAY MEMORY
FADER MODE
LAYER
DISPLAY MEMORY
FADER MODE
Ingresso ANALOGICO
ANALOG Input
Collegamento in cascata
Link connections
Ingresso DIGITALE
DIGITAL inputA B
BALANCED AUDIO INPUTS
-6dB
PUSH PUSH
IN OUT
AES EBUPUSH
Oppure
or
Oppure
or
Menu Option configurationOption
Menu Option configurationOption Menu Option configurationOption
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type Analog
AES out An In
Input type Analog
AES out An In
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
59 60
InA-B Src Dig InInA-B Src Dig InInA-B Src An InInA-B Src An In
frequenzaHz
dB
Gu
ad
ag
no
60 200 2800
0dB0dB
-6dB
Esempio di un sistema a 3-vie
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
Out 1 Out 2 Out 3
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Esempio di un sistema a 3-vie
61 62
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
26NAC 26NAC
R TE
DO
R
MO LEU O R CE S
E O TR L A
S O
O C ND I P
P hsuernE t
o su cti nF nel rS e tc o
E CSME UN
IGCHTE OL SN EOBd
ocaL l
M
0
484
467
430
44
31
75
12
7
DIMENSIONI DIMENSIONSABMESSUNGEN DIMENSIONS
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
2 VIE ATTIVO2 WAY ACTIVE
3 VIE PASSIVO3 WAY PASSIVE
L
L
A
A
HIGH L
MID L
LOW HIGHMID RHIGHMID L
LOW L
HIGH R
MID R
LOW R
R
R
B
B
1
1
2
2
3
3
456
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
BBdd TECHNOLOGIESTECHNOLOGIES
00
PEAK LIMITERPEAK LIMITER
SIGNAL -20dBSIGNAL -20dBTEMPTEMP
MUTE PROTMUTE PROT
CH2CH2CH1CH1 ONON0000
3333
6666
9999
12121212
15151515
18181818
TEMPTEMP
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A
Out 4 Source In B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
Menu Matrix configurationMatrix
57 58
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
XO
VE
R2
X1
2-2
4-4
8d
B
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
PE
Q1
2B
Q
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
DE
LA
Y3
40
ms
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
E
PH
AS
EROUIG ATRIX TNM
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
LE
VE
L(M
UT
E)
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
CO
MP
LIM
ITE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
ME
TE
R
OU
TP
UT
1
OU
TP
UT
2
OU
TP
UT
3
OU
TP
UT
4
OU
TP
UT
5
OU
TP
UT
6
AE
S-E
BU
OU
TP
UT
INP
UT
A
AE
S-E
BU
INP
UT
INP
UT
B
D D D D D D
D D
A A A A A A
A SA
MP
LE
RA
TE
CO
NV
A
LIN
KA
BL
E
SC
HE
MA
A B
LO
CC
HI -
BL
OC
K D
IAG
RA
MB
LO
CK
SC
HA
LT
BIL
D -
SC
HE
MA
S F
ON
CT
ION
NE
LS
LINE ARRAY SUB MONO ATTIVO
LINE ARRAY SUB MONO ACTIVEINGRESSI - INPUT
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
L
L
L
A
A
A
AESEBU IN
AESEBU IN
AESEBU IN
AESEBU OUT
AESEBU IN
AESEBU IN
AESEBU OUT
R
R
R
LR
B
B
B
123456
HIGHMID L
HIGHMID L HIGHMID R
HIGHMID R
LOW L LOW R
LAYER
DISPLAY MEMORY
FADER MODE
LAYER
DISPLAY MEMORY
FADER MODE
Ingresso ANALOGICO
ANALOG Input
Collegamento in cascata
Link connections
Ingresso DIGITALE
DIGITAL inputA B
BALANCED AUDIO INPUTS
-6dB
PUSH PUSH
IN OUT
AES EBUPUSH
Oppure
or
Oppure
or
Menu Option configurationOption
Menu Option configurationOption Menu Option configurationOption
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type Analog
AES out An In
Input type Analog
AES out An In
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
59 60
InA-B Src Dig InInA-B Src Dig InInA-B Src An InInA-B Src An In
frequenzaHz
dB
Gu
ad
ag
no
60 200 2800
0dB0dB
-6dB
Esempio di un sistema a 3-vie
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
Out 1 Out 2 Out 3
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Esempio di un sistema a 3-vie
61 62
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
26NAC 26NAC
R TE
DO
R
MO LEU O R CE S
E O TR L A
S O
O C ND I P
P hsuernE t
o su cti nF nel rS e tc o
E CSME UN
IGCHTE OL SN EOBd
ocaL l
M
0
484
467
430
44
31
75
12
7
DIMENSIONI DIMENSIONSABMESSUNGEN DIMENSIONS
LINE ARRAY SUB MONO ATTIVO
LINE ARRAY SUB MONO ACTIVEINGRESSI - INPUT
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
AC 26NAC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
L
L
L
A
A
A
AESEBU IN
AESEBU IN
AESEBU IN
AESEBU OUT
AESEBU IN
AESEBU IN
AESEBU OUT
R
R
R
LR
B
B
B
123456
HIGHMID L
HIGHMID L HIGHMID R
HIGHMID R
LOW L LOW R
LAYER
DISPLAY MEMORY
FADER MODE
LAYER
DISPLAY MEMORY
FADER MODE
Ingresso ANALOGICO
ANALOG Input
Collegamento in cascata
Link connections
Ingresso DIGITALE
DIGITAL inputA B
BALANCED AUDIO INPUTS
-6dB
PUSH PUSH
IN OUT
AES EBUPUSH
Oppure
or
Oppure
or
Menu Option configurationOption
Menu Option configurationOption Menu Option configurationOption
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type AES
AES out Dig In
Input type Analog
AES out An In
Input type Analog
AES out An In
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Out 1 Source In A
Out 2 Source In B
Out 3 Source In A+B
Out 4 Source In A+B
Out 5 Source In A
Out 6 Source In B
Menu Matrix configurationMatrix
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
59 60
InA-B Src Dig InInA-B Src Dig InInA-B Src An InInA-B Src An In
frequenzaHz
dB
Gu
ad
ag
no
60 200 2800
0dB0dB
-6dB
Esempio di un sistema a 3-vie
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
1HP48 60Hz LP24 200Hz
2HP24 200Hz LP12 2800Hz
3HP12 2800Hz Dis --Hz
Out 1 Out 2 Out 3
Ch ob
Option
X-Over
Ch ob
Option
X-Over
Meters
Preset
Matrix
Meters
Preset
Matrix
Esempio di un sistema a 3-vie
61 62
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
26NAC 26NAC
R TE
DO
R
MO LEU O R CE S
E O TR L A
S O
O C ND I P
P hsuernE t
o su cti nF nel rS e tc o
E CSME UN
IGCHTE OL SN EOBd
ocaL l
M
0
484
467
430
44
31
75
12
7
DIMENSIONI DIMENSIONSABMESSUNGEN DIMENSIONS
61 62
AC 26N
REMOTE CONTROLLED AUDIO PROCESSOR PushEnter
FunctionsSelector
ESC MENU
TECHNOLOGIESBd Local
M
0
26NAC 26NAC
R TE
DO
R
MO LEU O R CE S
E O TR L A
S O
O C ND I P
P hsuernE t
o su cti nF nel rS e tc o
E CSME UN
IGCHTE OL SN EOBd
ocaL l
M
0
484
467
430
44
31
75
12
7
DIMENSIONI DIMENSIONSABMESSUNGEN DIMENSIONS