8
56" Instruction Manual SAFETY GUIDELINES AND INSTALLATION PROCEDURES RCF-LE800-5BL REMOTE CONTROL CEILING FAN WITH LIGHT

REMOTE CONTROL CEILING FAN WITH LIGHT · 3 ) Ceiling fan installation and electrical wiring must be done by qualified technician in accordance with all applicable codes and air conditioning

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: REMOTE CONTROL CEILING FAN WITH LIGHT · 3 ) Ceiling fan installation and electrical wiring must be done by qualified technician in accordance with all applicable codes and air conditioning

56"

Instruction ManualSAFETY GUIDELINES AND INSTALLATION PROCEDURES

RCF-LE800-5BL

REMOTE CONTROL CEILING FAN WITH LIGHT

Page 2: REMOTE CONTROL CEILING FAN WITH LIGHT · 3 ) Ceiling fan installation and electrical wiring must be done by qualified technician in accordance with all applicable codes and air conditioning

13

WHAT YOU HAVE Please checkout following parts after opening the box:

COMPONENTS

PARTS QUANTITY 1.DOWNROD 12.TOP CANOPY 1

4. FAN HOUSING & MOTOR1

7. BLADE HOLDERS

3. COUPLING COVER

5. SWITCH COVER

6. GLASS SHADE

8. BLADES9. BLADE DECORATIVE COVERS

11

5A. LIGHT KIT & LED LAMP(7W) 1

5

55

SCREW PACKAGE

SCREW PACKAGE

13.BLADE HOLDER SCREWS 11

12. S BLADE DECORATIVE COVER CREWS 16

QUANTITY

14.EXPANSION J HOOK

10.PARTS QUANTITY

1

1

1

15.BALANCING KIT 1

15

DIGITAL TOUCH SCREEN REMOTE (COMES WITH 3V BATT X2)

12

14

11. RF RECEIVER 1

Page 1

10A. REMOTE HOLDER WITH 2 MOUNTING SCREWS

FAN SIZE VOLTAGE CARTON WEIGHT

56” 80W 250+-10% 8.13kg 9.13kg

MAX. FAN POWER

MAX SPEED (RPM)

PRODUCT WEIGHT

220 240V/50Hz

2

1

8

3

4

7

5

HI

MED

LOW

OFF

1H

3H

6H 10

9

10A

6

5A

11

LIGHT POWER

7W Led

Page 3: REMOTE CONTROL CEILING FAN WITH LIGHT · 3 ) Ceiling fan installation and electrical wiring must be done by qualified technician in accordance with all applicable codes and air conditioning

Double pole single throw switch(Breaker Switch)

Earth

Ceiling Fan

Wall Switch (OFF/ON)

240VAC/50HzPower Supply

Page 2

1 ) Please do not install the ceiling fan at high humidity areas. 2 ) Distance between fan blades and ground must be at least 2.5 meter and above.3 ) Do not touch fan blades with any objects when the ceiling fan is spinning. 4 ) To minimize the chances of electrical shock, power switch must be OFF before installing or dismantling the ceiling fan or any electrical wiring connection. 5 ) All electrical connections must conform to the national electrical safety codes. To prevent electrical shock, earth wire must be installed correctly (suitable for power supply of 240V AC/50Hz). 6 ) To ensure your personal safety and optimize functions of the ceiling fan, assembly and installation by qualified technician is highly recommended. 7 ) Only direct connection to wall switch is allowed. Please refer to diagram below.

WARNING

1 ) Do not bend the blade holders during installation, blades balancing or fan cleaning.2 ) To prevent accidents, power switch must be OFF before ceiling fan installation. 3 ) Ceiling fan installation and electrical wiring must be done by qualified technician in accordance with all applicable codes and air conditioning engineers (ASHRAE) or the local qualified authorities. 4 ) Be cautious when drilling the wall to avoid damaging electrical wiring and other hidden parts. 5 ) Ceiling fan must be hooked on concrete ceiling. Do not install the ceiling fan on plaster ceiling or any types of drywall ceilings. During ceiling fan installation, all screws must be tightened at all allocated parts.

8 ) This product is not provided with cord, plug or other means for disconnection from the supply. Connecting or changing power cord or lead wire, must be done by qualified personnel in order to avoid hazard. 9 ) This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.10 ) Children should be supervised to ensure that they do not play with the appliance.11 )

A). TO ENSURE YOUR PERSONAL SAFETY, PLEASE READ THROUGH THEINSTRUCTION MANUAL BEFORE USE

B). SAFETY GUIDELINES

The ceiling fan must be installed with means for disconnection incorporated in the fixed wiring(wall switch)in accordance with the wiring rules.

Page 4: REMOTE CONTROL CEILING FAN WITH LIGHT · 3 ) Ceiling fan installation and electrical wiring must be done by qualified technician in accordance with all applicable codes and air conditioning

Page 3

DIAGRAM 2

1 ) Remove 1st hex-head screw along with the fixings (pin, metal nut, lock washer and metal washer) from the downrod. 2 ) Remove the pin on 2nd hex-head screw and loosen the other fixings.

1 ) Lift the fan until the hanging wheel seat on the mounted J hook.2 ) Install the 1st hex-head screw together with fixings. 3 ) Tighten up the 2nd hex-head screw and fixing.

DIAGRAM 1

DIAGRAM 3

Safety Cable C

Wire

Light Connector

onnector

Top Canopy

Coupling Cover

Screw x 2

Hex-head Screw

Motor Coupling

The 1st Hex-head Screw

PinMetal Nut

Metal Nut

Lock WasherMetal Washer

The 2nd Hex-head Screw

Pin

Terminal Block

Fixings

Screw (Loosen)

(Tighten)

Hook

The 1st Hex-head Screw

The 2nd Hex-head Screw

1 ) Loosen 2 screws on the motor coupling.2 ) Insert the downrod through top canopy and coupling cover. 3 ) Thread the safety cable through the downrod. 4 ) Connect both wire and light connectors from downrod to fan motor.5 ) Lock the downrod to the motor coupling, tighten up with 2 hex-head screws and fixings.6 ) Tighten 2 screws on the motor coupling.7 ) Slide down the coupling cover until it rest on top of the fan housing.

Downrod

Installation without proper procedures as above mentioned might result to fan loosening or falling.

INSTALLATION PROCEDURESBefore ceiling fan installation,please go through the procedures in detail with picture diagram as reference.

STEP 1 (See Diagram 1)

STEP 2 (See Diagram 2)

STEP 3 (See Diagram 3)

WARNING:

Metal Washer

PinMetal NutLock Washer

Fixings

Note:-

2. Hook must be installed on concrete ceiling.

(2.5 Nm torque for hex-head screws and Metal Nut)

1. Remember to lock the pin after tightening hex-head screws.

Page 5: REMOTE CONTROL CEILING FAN WITH LIGHT · 3 ) Ceiling fan installation and electrical wiring must be done by qualified technician in accordance with all applicable codes and air conditioning

Page 4

Fit the connected receiver into top canopy. Then, tighten the screw on downrod.

DIAGRAM 5

DIAGRAM 4

Receiver

Ceiling

Ceiling

Ceiling

Receiver

Receiver

Receiver

Receiver

Brown Wire(TO MOTOR L)

Blue W

(Orange Wire)(FOR LIGHT)

ire(TO MOTOR N)

Red / Brown Wire(Incoming LIVE Wire)

Black / Blue Wire(Incoming NEUTRAL Wire)

Green Wire(Incoming EARTH Wire)

Red Wire (AC in L)

Black Wire (AC in N)

Terminal Block (marked )“L”

Terminal Block (marked )“N”

Terminal Block (marked )“ ”

FROM TO

! Connect the Motor Wiring to Receiver first!Connect wiring as below:-

Downrod

Receiver

T

Screw

op Canopy

LIV

E w

ire

(Red

/ B

row

n)

NE

UT

RA

L w

ire

(Bla

ck /

Blu

e )

Terminal Block (marked )“

STEP 4 (See Diagram 4)

SUPPLY CIRCUIT

STEP 5 (See Diagram 5)

E

AR

TH w

ire

LN

LN

LN

FOR

LIG

HT

FOR

LIG

HT

OrangeGreen

BrownBlue

Receiver

Page 6: REMOTE CONTROL CEILING FAN WITH LIGHT · 3 ) Ceiling fan installation and electrical wiring must be done by qualified technician in accordance with all applicable codes and air conditioning

Page 5

Blade holder

Fan Blade

Decorative Cover

DIAGRAM 7

Switch CoverKey Hole 1

Mounting Ring

Key Hole 2

Fan Motor

Fan Motor

Fan MotorBlade Holder

Fan Blade

Decorative Cover

Screw

Screw

Screw

Orange Blue

Blue

Light kitLed lamp

BLack

ScrewX10

Plastic Block(Must Remove)

DIAGRAM 8

DIAGRAM 9

DIAGRAM 6

1 ) Screw the blade holder onto the fan blade and decorative cover. 2 ) Repeat same step on all the remaining fan blades.

1 ) Rem

to the blue wire from

ove 1 screw from the mounting ring and loosen the other 2 (Do not remove). 2 ) Place the key hole 1 of switch coverthrough the 2 loosen screws and twist to lock in place. 3 ) Tighten u

black wire from light kit.

p all screws including the one removed earlier.

5 ) Tighten up all screws including the o

Install the glass shade by twisting clockwise(To unlock, twist anticlockwise).

ne removed earlier.

4 ) Remove the 1 screws on key hole 2(Do not remove). and loosen the other 2

Connect the blue wireConnect the

from motor housing light kit.

orange wire from motor housing to the

1 ) Remove all the plastic blocks and 10 screws from the motor housing. 2 ) Place assembled fan blades onto the motor housing and tighten up all screws removed previously.

Note:- 1. There are total of 10 screws holding fan blades to the motor housing. 2. Plastic blocks must be removed and discarded.

STEP 6 (See Diagram 6)

STEP 7 (See Diagram 7)

STEP 8 (See Diagram 8)

STEP 9 (See Diagram 9)Switch Cover

Glass shade

Page 7: REMOTE CONTROL CEILING FAN WITH LIGHT · 3 ) Ceiling fan installation and electrical wiring must be done by qualified technician in accordance with all applicable codes and air conditioning

Page 6

WARNING!FASTEN THE SAFETY CABLE TO THE MOUNTED J HOOK FOR

SAFETY PURPOSES.

Page 8: REMOTE CONTROL CEILING FAN WITH LIGHT · 3 ) Ceiling fan installation and electrical wiring must be done by qualified technician in accordance with all applicable codes and air conditioning

Page 7

FLOOR

MIN 2.5m

SAFETY TIPS

Please ensure the distance between fan blade and ground must be at least 2.5meter and above.