RELIABILITY ON DEMAND INTRODUCING A COMPLETE LINE OF TANKLESS GAS WATER HEATERS. American On-Demand Gas Water Heaters. A full product line of tankless water heaters by American. Utilized for Residential or Commercial applications. Interior and Exterior installation options. - PowerPoint PPT Presentation

Citation preview

  • RELIABILITY ON DEMANDINTRODUCING A COMPLETE LINE OF TANKLESS GAS WATER HEATERS

  • American On-Demand Gas Water HeatersA full product line of tankless water heaters by American.Utilized for Residential or Commercial applications.Interior and Exterior installation options.Natural Gas or Propane.16 different models covering a range of needs.

    1

  • Rely on AmericanBenefit from the always reliable customer service of American and the comfort of endless hot water.Combine the efficiency of the tankless technology with the expertise of the American brand.Gain greater flexibility when it comes to controlling water temperature in the home.

    2

  • Reliable TechnologyOn board diagnostics and safety monitoringEnergy efficient, up to 84% thermal efficiencyContinuous hot water up to 9.8 GPM (maximum flow rate)Direct electronic ignition; no pilot lightDurable enough for 12-year limited warranty on heat exchanger and 5-year warranty on all partsUp to 237,000 maximum gas consumption Btu/hNatural gas or propane

    3

  • Inspired ComfortAll models come with a Standard Remote Controller that can set the temperature within a specific range and can provide error codes to diagnose problems.The Commercial Remote Controller can be used to achieve temperatures above 140F, up to 160F for the 305 models and up to 185F for the 505 and 705 models.

    4

  • Remote ControllerOn/Off ButtonWill turn the water heater on/offIn Use Indicator LightIndicates hot water is being supplied (a tap is open)Temperature DisplayShows the temp settingError CodesWhen a fault is detected an error code flashes at the temperature settingThermostatIncreases/decreases temp settingPriority ButtonPriority can be changed to another controller if desiredPriority IndicatorIndicates that this controller is setting the temperature5

  • On-Demand Models

  • 305 Model SpecificationsModel numbers:Interior: GT-305-NI and GT-305-PIExterior: GT-305-NE and GT-305-PEBtu/h Input:Minimum 15,000/Maximum 199,000Flow rate:Minimum 0.6 GPM/Maximum 5.3 GPMEfficiency rating:Interior 84%/Exterior 83%Weight:50 lb.7

  • 505 Model SpecificationsModel numbers:Interior: GT-505-NI and GT-505-PIExterior: GT-505-NE and GT-505-PEBtu/h Input:Minimum 15,000/Maximum 199,000Flow rate:Minimum 0.6 GPM/Maximum 8.5 GPMEfficiency rating:Interior 84%/Exterior 83%Weight:50 lb.8

  • 705 Model Specifications*Model number:Interior: GT-705-NI and GT-705-PIExterior: GT-705-NE and GT-705-PEBtu/h Input:Minimum 19,000/Maximum 237,000Flow rate:Minimum 0.6 GPM/Maximum 9.8 GPMEfficiency rating:Interior 84%/Exterior 83%Weight:55 lb.*ASME models also available:Interior: AGT-705-NI and AGT-705-PIExterior: AGT-705-NE and AGT-705-PE9

  • Model Specifications Overview10

  • Multi-System OptionsConnection cable or kits are available for multi-system integration.11

  • Sizing

  • Model Selection GuideTo properly size On-Demand units for a home, two factors are of critical importance . . .Incoming ground water temperature-Will determine the amount of temperature rise required to achieve the desired hot water outlet temperature (120F is recommended)Peak hot water demand-How much hot water the home will need during its busiest usage period13

  • Ground Water Temperature Factor14

  • Peak Hot Water DemandConsider all the applications and fixtures in the home that use hot water, including lavatory faucets, kitchen faucets, washing machines, dishwashers, showers and bathtubs.Determine how many of these appliances and fixtures will be in use at the same time during the busiest usage period.For example, if one kitchen faucet, one shower and a washing machine are all in use during the busiest period, use the number 3 to make your selection from the Model Selection Guide.15

  • Model Selection Guide16

  • Technical Information

  • Outlet Flow Data18

  • Pressure Drop Curve19

  • Dimensions Interior Models305/505705DIM DESCRIPTIONIn (mm)In (mm)AWidth14 (355.6)18.5 (470)BDepth*9.6 (244.5)9.1 (230.5)CHeight: Unit22.9 (582)23.6 (600)DHeight: w/Brackets25.5 (648.2)25.2 (640)EHot water outlet: from wall3.6 (91)4.3 (110)FHot water outlet: from center4.3 (110)2.4 (61)GCold water inlet: from wall2.8 (70)3.7 (94)HCold water inlet: from center1.1 (27)2.0 (52)IGas connection: from wall4.3 (109)2.2 (56.2)JGas connection: from center3.5 (89)4.3 (110)KFrom base to gas connection1.6 (40)1.6 (40)From base to cold connection2.0 (50)2.0 (50)From base to hot connection1.6 (41)1.6 (41)

    *This is the minimum dimension from the wall.20

  • Dimensions Exterior Models305505705DIM DESCRIPTIONIn (mm)In (mm)In (mm)AWidth14 (355.6)14 (355.6)18.5 (470)BDepth7.7 (196)9.8 (249.5)9.3 (236)CHeight: Unit19.8 (503)22.9 (582)23.6 (600)DHeight: w/Brackets22.5 (571)25.4 (646.4)25.2 (640)EHot water outlet: from wall3.4 (87)3.8 (96)4.5 (115)FHot water outlet: from center4.1 (105)4.3 (110)2.4 (61)GCold water inlet: from wall2.7 (68)2.6 (75)3.9 (99)HCold water inlet: from center0.4 (10)1.1 (27)2.0 (52)IGas connection: from wall3.0 (77)4.1 (104)2.4 (61.2)JGas connection: from center3.3 (83)3.5 (89)4.3 (110)KFrom base to gas connection1.6 (40)1.6 (40)1.6 (40)From base to cold connection2.0 (50)2.0 (50)2.0 (50)From base to hot connection1.6 (41)1.6 (41)1.6 (41)21

  • Pipe Sizing22

  • Piping for Basic InstallationEquipment List:1 Water Heater1 Plumbing Installation Kit (Optional)2 Unions2 Ball Valves2 Drain Valves1 Pressure Relief Valve23

  • Flue Terminal Clearances Interior ModelsU.S.DIM DESCRIPTIONInstallationsAClearance above grade, veranda, porch,12 (30 cm)deck, or balconyBClearance to window/door that may be open 12 (30 cm)CClearance to permanently closed window*DVertical clearance to ventilated soffit, located*above terminal within horizontal distance of2 ft. (61 cm) from center line of terminalEClearance to unventilated soffit*FClearance to outside corner*GClearance to inside corner*HClearance to each side of center line extended*above meter/regulator assemblyIClearance to service regulator vent outlet*JClearance to non-mechanical air supply 12 (30 cm)inlet to building or combustion air inletto any other applianceKClearance to a mechanical air supply3 (91 cm) aboveinletif w/i 10 ft. (3 m)horizontallyLClearance above paved sidewalk/paved*driveway located on public propertyMClearance under veranda, porch, deck, balcony*

    *For clearances not specified in ANSI Z223.1/NFPA 54 or CSA B149.1, clearances are in accordance with local installation codes and the requirements of the gas supplier.24

  • Flue Terminal Clearances Exterior ModelsU.S.DIM DESCRIPTIONInstallationsAClearance above grade, veranda, porch,12 (30 cm)deck, or balconyBClearance to window/door that may be open 12 (30 cm)CClearance to permanently closed window*DVertical clearance to ventilated soffit, located*above terminal within horizontal distance of2 ft. (61 cm) from center line of terminalEClearance to unventilated soffit*FClearance to outside corner*GClearance to inside corner*HClearance to each side of center line extended*above meter/regulator assemblyIClearance to service regulator vent outlet*JClearance to non-mechanical air supply 12 (30 cm)inlet to building or combustion air inletto any other applianceKClearance to a mechanical air supply3 (91 cm) aboveinletif w/i 10 ft. (3 m)horizontallyLClearance above paved sidewalk/paved*driveway located on public propertyMClearance under veranda, porch, deck, balcony*

    *For clearances not specified in ANSI Z223.1/NFPA 54 or CSA B149.1, clearances are in accordance with local installation codes and the requirements of the gas supplier.25