16
Release Notes SmartRadar FlexLine

Release Notes SmartRadar FlexLine - Honeywell · Release Notes 2 - 1 CHAPTER 2 BEFORE YOU BEGIN 2.1 Check for updates on Honeywell Process Solutions website In our effort to provide

  • Upload
    others

  • View
    14

  • Download
    1

Embed Size (px)

Citation preview

Release NotesSmartRadar FlexLine

© 2014 - Honeywell International Inc.

Contact Information:

Head Office - Delft, The Netherlands

Honeywell EnrafDelftechpark 39, 2628 XJ DelftPO Box 812, 2600 AV DelftThe Netherlands

Tel.: +31 (0)15 2701 100Fax: +31 (0)15 2701 111

E-mail: enraf.helpdesk@honeywell .comWebsite: http://www.honeywell.com/ps

Table of Contents

Part No.: 4417658 SmartRadar FlexLineRelease Notes 1 - i

CHAPTER 1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1

1.1 About the Release Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1

1.2 Target Group for this Release Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1

1.3 Related Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1

1.3.1 ISA100 SmartRadar FlexLine User's Guide . . . . . . . . . . . . . . . . . . . . . . . . . 1-1

1.3.2 Wireless Device Manager User's Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1

1.3.3 OneWireless R220 Migration User's Guide . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1

1.4 Trademarks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1

1.5 Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1

CHAPTER 2 Before you begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1

2.1 Check for updates on Honeywell Process Solutions website. . . . . . . . . 2-1

2.2 Supported migration paths. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4

CHAPTER 3 What’s new in ISA100 FlexLine R220 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1

3.1 ISA100 standard compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1

3.2 Protocol tunneling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1

3.3 Over-the-air firmware upgrade feature . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1

3.4 Over-the-air provisioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2

3.5 Block instantiation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2

3.6 Meshing (routing) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2

CHAPTER 4 ISA100 FlexLine Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1

4.1 Prerequisites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1

4.1.1 Supported browsers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1

4.1.2 Supported Silverlight plug-in versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1

CHAPTER 5 Known issues in ISA100 FlexLine R220 . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1

5.1 Field devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1

CHAPTER 6 Revision information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1

6.1 Firmware revision of ISA100 FlexLine components. . . . . . . . . . . . . . . . . 6-1

General

CHAPTER 1 GENERAL

1.1 About the Release Notes

This Release Notes describes the new functions and the features in the ISA100 FlexLine R220. In our efforts to provide the most up-to-date information, updates to this Release Notes are available on the Honeywell Online Support website.

1.2 Target Group for this Release Notes

The SmartRadar FlexLine Release Notes is intended for service engineers who are assigned to provision, configure, operate, and monitor an ISA100 wireless field device network using the SmartRadar FlexLine field devices.

1.3 Related Documents

1.3.1 ISA100 SmartRadar FlexLine User's Guide

The ISA100 SmartRadar FlexLine User's Guide provides information about provisioning, configuring, operating, and monitoring the ISA100 wireless field device network using the SmartRadar FlexLine field devices.

1.3.2 Wireless Device Manager User's Guide

The Wireless Device Manager User's Guide provides information about installing, configuring, operating, monitoring, and maintaining the ISA100 wireless field device network using the Wireless Device Manager.

1.3.3 OneWireless R220 Migration User's Guide

The OneWireless R220 Migration User's Guide provides information about migrating from OneWireless R202 to R210, OneWireless R120 to R220 (that is, proprietary to ISA100 compliant), and OneWireless R210 to R220 (that is, previous to latest release).

1.4 Trademarks

HART® is a registered trademark of the HART Communication Foundation.

1.5 Contact

Head Office - Delft, The Netherlands

Part No.: 4417658 SmartRadar FlexLineRelease Notes 1 - 1

General

Honeywell Enraf

Delftechpark 39, 2628 XJ Delft

PO Box 812, 2600 AV Delft

The Netherlands

Tel.: +31 (0)15 2701 100

Fax: +31 (0)15 2701 111

E-mail: enraf.helpdesk@honeywell .com

Website: http://www.honeywell.com/ps

SmartRadar FlexLine Part No.: 44176581- 2 Release Notes

Before you begin

CHAPTER 2 BEFORE YOU BEGIN

2.1 Check for updates on Honeywell Process Solutions website

In our effort to provide the most up-to-date information, updates to this Release Notes are available on the Honeywell Process Solutions website.

Before you install this software revision, check the Honeywell Process Solutions website for updates. If you are a new user, register at URL - http://www.honeywellprocess.com.

Download Honeywell software updates, documentation, and recommended antivirus updates from the Honeywell Process Solutions website (http://www.honeywellprocess.com).

To access the Honeywell Process Solutions website

1. In a web browser, type the following URL.

http://www.honeywellprocess.com.

2. If you are a new user, register at this website. Click Register, and follow the on-screen instructions.

3. If you are already registered, type your user name and password, and click Login on the login page.

The Home page, along with your registered name appears.

To download documents, security updates, or antivirus notifications

1. On the Home page, click the Support tab.

The Product Support page appears.

2. In the Search box, type the name of the required document, security update, or antivirus notification. For example, to download the Release Notes, type SmartRadar FlexLine Release Notes in the Search box and click Search.

Part No.: 4417658 SmartRadar FlexLineRelease Notes 2 - 1

Before you begin

The All Support Search Results page appears with the search results.

3. In the left pane, use the Search Result Filters to further filter the document, security update, or antivirus notification. For example, if you are locating a Release Note:

a) Under Document Type, click the required document type.

b) Under Product Release, click the required FlexLine product release.

SmartRadar FlexLine Part No.: 44176582 - 2 Release Notes

Before you begin

4. Click the document, security update, or antivirus notification link to open it.

Part No.: 4417658 SmartRadar FlexLineRelease Notes 2 - 3

Before you begin

2.2 Supported migration paths

Following are the ISA100 FlexLine supported migration paths. For more information about the migration procedures, refer to the SmartRadar FlexLine Migration User’s Guide.

You must migrate to the R120.1 patch 12 first and then migrate to R220. Ensure that the R120.1 patches are installed on the OneWireless server, and the firmware is updated on multinodes and field devices before migrating to R220.

The following are the supported migration paths for the OneWireless Network.

Current Release Migration path to be followed

OneWireless R120.1 Patch 4/Patch 5/Patch 6

OneWireless R120.1 Patch 4/Patch 5/Patch 6 > One-Wireless R120.1 Patch 7 > OneWireless R120.1 Patch 11 > OneWireless R120.1 Patch 12 > OneWireless R220.1

OneWireless R120.1 Patch 7/Patch 8/Patch 9/Patch 10

OneWireless R120.1 Patch 7/Patch 8/Patch 9/Patch 10 > OneWireless R120.1 Patch 11 > > OneWireless R120.1 Patch 12 > OneWireless R220.1

OneWireless R220.1 (Intermediate)

OneWireless R220.1

SmartRadar FlexLine Part No.: 44176582 - 4 Release Notes

What’s new in ISA100 FlexLine R220

CHAPTER 3 WHAT’S NEW IN ISA100 FLEXLINE R220

3.1 ISA100 standard compliance

The SmartRadar FlexLine field device exchanges information with any system that supports the ISA100 standard network.

OneWireless network is compliant with the ISA100 standard that mandates interoperable, reliable, and secure wireless operation for applications ranging from non-critical monitoring to closed loop control systems.

3.2 Protocol tunneling

OneWireless R220 WDM supports GPU and Flexconn protocol tunnel. WDM uses the protocol tunneling feature to provide the applications (Engauge tool/CIU Prime) for configuring and monitoring the SmartRadar FlexLine field devices wirelessly.

Protocol tunneling can be established for the SmartRadar FlexLine field device in the following ways.

1. Serial tunneling through RS-232 or RS-485: The serial RS-232 is configured on COM1 of the WDM and serial RS-485 is configured on COM2 of the WDM.

2. Ethernet/UDP tunneling: Multiple clients are supported with the Ethernet/UDP.

NOTE: Redundancy is not supported with the serial RS-232 protocol tunneling.

The supported Engauge tool version is v2.6.

3.3 Over-the-air firmware upgrade feature

The over-the-air upgrade feature provides the ability to upgrade the application firmware on the CAN-1WL board through the OneWireless user interface.

The sensor boards (TII-XR, FCI-HT, FII-VT, FII-SMV, FII-RTD, HCI-GPU, HCI-BPM, and FII-DO) can be upgraded through the Engauge tool wirelessly.

NOTE: You must not upgrade the HCI-1WL (CAN-1WL) board using the Engauge tool because the SmartRadar FlexLine field device drops from the network permanently and it also damages the card.

Part No.: 4417658 SmartRadar FlexLineRelease Notes 3 - 1

What’s new in ISA100 FlexLine R220

3.4 Over-the-air provisioning

Over-the-air provisioning allows you to provision an FDAP, Cisco Aironet 1552S AP, Multinode, or SmartRadar FlexLine field devices wirelessly.

3.5 Block instantiation

OneWireless supports block instantiation for SmartRadar FlexLine field device channels. You can add, remove, and reconfigure channels supported by the SmartRadar FlexLine field devices.

3.6 Meshing (routing)

The SmartRadar FlexLine field device supports routing as per ISA100 standards. That is, the SmartRadar FlexLine field device can be routed through another SmartRadar FlexLine field device.

The device can be configured as routing or non-routing from the ISA100 system user interface. The device joins the network as a routing device by default.

NOTE: For more information about the new features, refer to the OneWireless R220 Release Notes.

SmartRadar FlexLine Part No.: 44176583 - 2 Release Notes

ISA100 FlexLine Configuration

Part No.: 4417658 SmartRadar FlexLineRelease Notes 4 - 1

CHAPTER 4 ISA100 FLEXLINE CONFIGURATION

4.1 Prerequisites

This section contains the prerequisites for the configuration of the SmartRadar FlexLine field devices.

4.1.1 Supported browsers

The following table lists all supported browsers for accessing the OneWireless R220 user interface.

{†1} Desktop mode only.

{†2} 64-bit mode support for Internet Explorer only.

NOTE: This interface can be used for accessing the SmartRadar FlexLine field devices.

4.1.2 Supported Silverlight plug-in versions

The minimum supported version of the Silverlight plug-in required to access the OneWireless R220 user interface is 5.1.20513.0. If the Silverlight plug-in is not installed or needs to be upgraded, you are prompted with instructions to install or upgrade the plug-in when attempting to connect to your WDM. The Microsoft Silverlight plug-in resides on the WDM.

Operating system Internet Explorer Firefox Google Chrome

Windows 8 {†1} {†2}

Windows Server 2012 {†1} {†2}

Internet Explorer 10 Firefox 17 or later Google Chrome 21 or later

Windows 7 SP1 {†2}

Windows Vista

Windows XP SP2, SP3

Windows Server 2008 R2 SP1 {†2}

Windows Server 2008 SP2

Windows Server 2003

Internet Explorer 7 or later

Firefox 3.6 or later Google Chrome 12 or later

Known issues in ISA100 FlexLine R220

Part No.: 4417658 SmartRadar FlexLineRelease Notes 5 - 1

CHAPTER 5 KNOWN ISSUES IN ISA100 FLEXLINE R220

5.1 Field devices

PAR Error Description, Recovery, and Workaround

1-2EDDHVV Error Indication Unable to configure negative transmitter power levels using the Engauge tool.

Description Transmit Power Level values can range from-5 dBm to 20 dBm. Negative Transmit Power Level values configured in Engauge tool are not displayed in the OneWireless User Interface.

Recovery Not applicable

Workaround Negative Transmit Power Level values may range from -5 to -1. Use 255 for -1, 254 for -2, 253 for -3, 252 for -4, and 251 for -5

Revision information

Part No.: 4417658 SmartRadar FlexLine Release Notes 6 - 1

CHAPTER 6 REVISION INFORMATION

6.1 Firmware revision of ISA100 FlexLine components

NOTE: For more information about the OneWireless components, refer to the OneWireless R220 Release Notes.

Component Firmware Revision

CAN1-WL A20262

Radio firmware OW220.1-68.0 (ORB)OW220.1-68.3 (LCRB)

Engauge tool version 2.6.4721.0

OneWireless system R220

Honeywell Enraf

Delftechpark 39

2628 XJ Delft

The Netherlands

Tel: +31 (0)15-2701 100

www.honeywell.com/ps

4417658 February 201 4© 2014 Honeywell International Inc.