Accessories for Great Indian Market 01
RelayAuxElectromechanical relays for auxiliary, tripping and control / supervision applications
CUSTOMER BENEFITS
• Plug-in compact design allows easy installation and replacement.
• Heavy duty contacts.
• High speed operation
• Universal change over contacts design facilitates easy selection and inventory reduction.
• Sturdy design for maximum reliability.
• Zero maintenance.
The auxiliary relays range offers varying levels of functionality to best suit the auxiliary, tripping and control/supervision application requirements, and allows the customers to choose the most cost effective solution to their various applications.
The design, durability and quality of the RelayAux make them suitable for high responsibility controls such as:
• Electrical utilities
• Power generation
• Electrical substations
• Transportation
• Industry - Oil & Gas - Food & beverage - Water - Mining, Minerals, metals ...
PM103544
RelayAuxAccessories for Great Indian Market 02
Range of productsAUXILIARY RELAYSThe main applications for this auxiliary relays range include
control & alarm functions, contact multiplication, interlocking,
customizing of protection schemes, indications or any other
auxiliary duties.
Models :
• Self reset relay, 4 or 8 contacts• Self reset relay with hand reset flag, 4 or 8 contacts• Electrical reset relay with following flag, , 4 or 8 contacts
TRIPPING RELAYSThe main applications for this high speed trip relays range include
lock out / master trip functions or high speed tripping applications
where auto-recloser is involved, which demands high speed operations.
These relays are used as interface between protection relay and
circuit breaker due to their high capacity contacts
Models :
• Self reset trip relay with hand reset flag, low burden, 4 or 8 contacts• Self reset trip relay with hand reset flag, high burden, 4 or 8 contacts• Electrical reset trip relay with following flag, low burden, 4 or 8 contacts• Electrical reset trip relay with following flag, high burden, 4 or 8 contacts• Hand and electrical reset trip relay with following flag, low burden, 4 or 8
contacts• Hand and electrical reset trip relay with following flag, high burden, 4 or 8
contacts
SUPERVISION RELAYSThe main applications for this supervision relays range include the
continuous supervision of the trip circuit in Pre-closed & Post-closed
conditions of a circuit breaker, the supervision of the master trip relay coil
or the supervision of the DC auxiliary supply circuits of the protection
schemes, avoiding false alarms due to short time drops of supply.
Models :
• DC supply supervision relay, 4 contacts• Trip circuit supervision relay or trip coil supervision relay (single phase
circuit breaker), 2 contacts• Trip circuit supervision relay (three phases circuit breaker), 2 contacts
PM103545
PM103546
PM103547
RelayAuxAccessories for Great Indian Market 03
Auxiliary relays
Models Self reset relay Self reset relay with hand reset flag Self reset relay Self reset relay with
hand reset flagConstruction characteristicsContacts no. 4 Changeover 8 Changeover
Connections
Coil characteristicsStandard voltages 110, 220 Vdc
Voltage range +10% -20%
Coil burden 3.9 W / 6 W
Performance data
Operating time < 20 ms
Operating temperature - 10°C + 55°C
Storage temperature - 30°C + 70°C
Maximum humidity 93 % / + 40°C
Operating altitude < 2000 m
ContactsPermanent current 10 A
Instantaneous current 110 A during 100 ms / 160 A during 30 ms
Max. making capacity 40 A / 0,5 s / 110 Vdc
Mechanical endurance: Unloaded contacts > 10 operations
Mechanical endurance: Loaded contacts Minimum of 50 000 operations are guaranteed
Max. breaking capacity – Contact circuit voltage : 220 Vdc
0 ms 20 ms 40 ms
P (W) I (A) P (W) I (A) P (W) I (A)
150 0.68 115 0.52 66 0.30
Braeking capacity
L/R= 0 ms L/R= 40 msResistive load (220 Vdc) Highly inductive load (220 Vdc)
0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80
10 7
10 6
10 5
10 4
Current
0.00 0.05 020 0.15 0.20 0.25 0.30 0.35
10 7
10 6
10 5
10 4
Current
50 000operations
50 000operations
No.
ope
ratio
ns
No.
ope
ratio
ns
RelayAuxAccessories for Great Indian Market 04
Auxiliary relays (cont.)
Models Electrical reset relay with following flagConstruction characteristicsContacts no. 4 Changeover 8 Changeover
Connections
Coil characteristicsStandard voltages 110, 220 Vdc
Voltage range +10% -20%
Coil burden 0 W (peak ≤ 15 W) / 0 W (peak ≤ 32 W)
Performance data
Operating time < 20 ms
Operating temperature - 40°C + 70°C
Storage temperature - 40°C + 70°C
Maximum humidity 93 % / + 40°C
Operating altitude < 2000 m
ContactsPermanent current 10 A
Instantaneous current 110 A during 100 ms / 160 A during 30 ms
Max. making capacity 40 A / 0,5 s / 110 Vdc
Mechanical endurance: Unloaded contacts > 10 operations
Mechanical endurance: Loaded contacts Minimum of 50 000 operations are guaranteed
Max. breaking capacity – Contact circuit voltage : 220 Vdc
0 ms 20 ms 40 ms
P (W) I (A) P (W) I (A) P (W) I (A)
150 0.68 115 0.52 66 0.30
Braeking capacity
L/R= 0 ms L/R= 40 msResistive load (220 Vdc) Highly inductive load (220 Vdc)
0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80
10 7
10 6
10 5
10 4
Current
0.00 0.05 020 0.15 0.20 0.25 0.30 0.35
10 7
10 6
10 5
10 4
Current
50 000operations
50 000operations
No.
ope
ratio
ns
No.
ope
ratio
ns
RelayAuxAccessories for Great Indian Market 05
Tripping relaysModels Self reset trip relay with hand reset flagConstruction characteristicsContacts no. 4 Changeover 8 Changeover
Connections
Coil characteristicsStandard voltages 110, 220 Vdc
Voltage range +10% -20%
Coil burden≤ 2,5 W (peak ≤ 66 W, 2 ms)
≤ 5 W (peak ≤ 110 W, 2,5 ms)
Performance data
Operating time < 10 ms
Operating temperature - 10°C + 55°C
Storage temperature - 30°C + 70°C
Maximum humidity 93 % / + 40°C
Operating altitude < 2000 m
ContactsPermanent current 10 A
Instantaneous current 110 A during 100 ms / 160 A during 30 ms
Max. making capacity 40 A / 0,5 s / 110 Vdc
Mechanical endurance: Unloaded contacts > 10 operations
Mechanical endurance: Loaded contacts Minimum of 50 000 operations are guaranteed
Max. breaking capacity – Contact circuit voltage : 220 Vdc
0 ms 20 ms 40 ms
P (W) I (A) P (W) I (A) P (W) I (A)
125 0.57 104 0.47 60 0.27
Braeking capacity
L/R= 0 ms L/R= 40 msResistive load (220 Vdc) Highly inductive load (220 Vdc)
0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80
10 7
10 6
10 5
10 4
Current
0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35
10 7
10 6
10 5
10 4
Current
50 000operations
50 000operations
No.
ope
ratio
ns
No.
ope
ratio
ns
RelayAuxAccessories for Great Indian Market 06
Tripping relays (cont.)
ModelsElectrical reset trip
relay with following flag
Hand and electrical reset trip relay with
following flag
Electrical reset trip relay with
following flag
Hand and electrical reset trip relay with
following flagConstruction characteristicsContacts no. 4 Changeover 8 Changeover
Connections
Coil characteristicsStandard voltages 110, 220 Vdc
Voltage range +10% -20%
Coil burden 0 W (peak ≤ 20 W) / 0 W (peak ≤ 40 W)
Performance data
Operating time < 10 ms
Operating temperature - 40°C + 70°C
Storage temperature - 40°C + 70°C
Maximum humidity 93 % / + 40°C
Operating altitude < 2000 m
ContactsPermanent current 10 A
Instantaneous current 110 A during 100 ms / 160 A during 30 ms
Max. making capacity 40 A / 0,5 s / 110 Vdc
Mechanical endurance: Unloaded contacts > 10 operations
Mechanical endurance: Loaded contacts Minimum of 50 000 operations are guaranteed
Max. breaking capacity – Contact circuit voltage : 220 Vdc
0 ms 20 ms 40 ms
P (W) I (A) P (W) I (A) P (W) I (A)
150 0.68 115 0.52 66 0.30
Braeking capacity
L/R= 0 ms L/R= 40 msResistive load (220 Vdc) Highly inductive load (220 Vdc)
0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80
10 7
10 6
10 5
10 4
Current
0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35
10 7
10 6
10 5
10 4
Current
50 000operations
50 000operations
No.
ope
ratio
ns
No.
ope
ratio
ns
RelayAuxAccessories for Great Indian Market 07
Tripping relays (cont.)
HIGH / LOW BURDEN CONFIGURATIONLow burden high speed tripping relays can be used when the initiating contact is placed close to the tripping relay.
However, in order to avoid unwanted trip relay operation due to pickup or transients, particularly if the relay operating coil is connected to extensive wiring, high burden high speed tripping relays can be used.High burden high speed tripping relays complies with ESI 48-4 international standard, as EB2 class relays.These EB2 class relays are suitable for use in high security circuit breaker tripping circuits, increasing their immunity to capacitance discharge currents.
For relays with rated voltage of 110 V, the relays will withstand, without operating a discharge into their operate circuits of a 10μF capacitor charged to 120% of the higher rated voltage for the relay, i.e 145.2 V.
For relays with rated voltage of 220 V, the relays will withstand, without operating a discharge into their operate circuits of a 10μF capacitor charged to 100% of the higher rated voltage for the relay, i.e 242 V.
RelayAuxAccessories for Great Indian Market 08
Supervision relaysModels DC supply supervision relayConstruction characteristicsContacts no. 4 Changeover
Connections
Coil characteristicsStandard voltages 110, 220 Vdc
Voltage range +10% -20%
Coil burden 3,9 W
Performance data
Operating time: Pick-up time < 20 ms
Operating time: Drop-out time > 200 ms
Operating temperature - 10°C + 55°C
Storage temperature - 30°C + 70°C
Maximum humidity 93 % / + 40°C
Operating altitude < 2000 m
ContactsPermanent current 10 A
Instantaneous current 15 A during 4 s
Max. making capacity 15 A during 4 s
Max. breaking capacity 0,3 A / 110 Vdc
Durability Relay designed to be permanently energized
RelayAuxAccessories for Great Indian Market 09
Supervision relays (cont.)
TRIP SUPPLY +
M +B
TRIP CONTACT
1
11
K1 K2 K1 K2
B1
12 8 2
2
2
2 9 813 129 13
4 55 1 4
TRIP CONTACT
SET RESET
TRIP SUPPLY -
TRIP SUPPLY +
TRIP SUPPLY -
Trip circuit supervision relay can also be used to supervise the trip circuit of the high speed tripping relays. If the circuit being supervised becomes an open circuit, the supervision relay will be de-energized and its output contacts will provide the related indications. In order to achieve this function, the relays should be connected as shown on the schemes :
Models Trip circuit supervision relay (single phase circuit breaker)
Trip circuit supervision relay (three phases circuit breaker)
Construction characteristicsContacts no. 2 Changeover
Connections
Coil characteristicsStandard voltages 110, 220 Vdc
Voltage range +10% -20%
Coil burden 3,1 W 3,6 W
Performance data
Operating time: Pick-up time < 20 ms
Operating time: Drop-out time > 200 ms
Operating temperature - 10°C + 55°C
Storage temperature - 30°C + 70°C
Maximum humidity 93 % / + 40°C
Operating altitude < 2000 m
ContactsPermanent current 8 A
Instantaneous current 15 A during 4 s
Max. making capacity 15 A during 4 s
Max. breaking capacity 0,3 A / 110 Vdc
Durability Relay designed to be permanently energized
RelayAuxAccessories for Great Indian Market 10
Environmental characteristics• Functional test : IEC 61810-7
• Electrical security standards : IEC 60255
• Environmental / Climatic standards : IEC 60068-2
• Vibration and shock stress standards : IEC 60068-2
• ESI 48-4 EB1 : 1983 Low Burden
• ESI 48-4 EB2 : 1983 High Burden
RelayAuxAccessories for Great Indian Market 11
Order Codes and Dimensions Auxiliary relays
ORDER CODESSchneider Electric
RelayAux Reference
RelayAuxType Contacts no. Aux. Supply Relay + Flush mounting socket
Self rest relay 4 changeover110 Vdc RELRAAS4110
220 Vdc RELRAAS4220
Self reset relay with hand reset flag 4 changeover110 Vdc RELRAAS4F110
220 Vdc RELRAAS4F220
Dimensions (mm) Panel Cut-Out (mm)
DIMENSIONS AND CUT-OUT
ORDER CODESSchneider Electric
RelayAux Reference
RelayAuxType Contacts no. Aux. Supply Relay + Flush mounting socket
Self rest relay 8 changeover110 Vdc RELRAAS8110
220 Vdc RELRAAS8220
Self reset relay with hand reset flag 8 changeover110 Vdc RELRAAS8F110
220 Vdc RELRAAS8F220
Dimensions (mm) Panel Cut-Out (mm)
DIMENSIONS AND CUT-OUT
RelayAuxAccessories for Great Indian Market 12
Order Codes and Dimensions (cont.)
Auxiliary relays
Schneider Electric RelayAux Reference
RelayAuxType Contacts no. Aux. Supply Relay + Flush mounting socket
Electrical reset relay with following flag 4 changeover
110 Vdc RELBAAE4110
220 Vdc RELBAAE4220
ORDER CODES
Dimensions (mm) Panel Cut-Out (mm)
DIMENSIONS AND CUT-OUT
Dimensions (mm) Panel Cut-Out (mm)
DIMENSIONS AND CUT-OUT
ORDER CODES Schneider Electric RelayAux Reference
RelayAuxType Contacts no. Aux. Supply Relay + Flush mounting socket
Electrical reset relay with following flag 8 changeover
110 Vdc RELBAAE8110
220 Vdc RELBAAE8220
RelayAuxAccessories for Great Indian Market 13
Order Codes and Dimensions (cont.)
Tripping relays
Schneider Electric RelayAux Reference
RelayAuxType Contacts no. Aux. Supply Relay + Flush mounting socket
Self reset trip relay with hand reset flag - Low burden 4 changeover
110 Vdc RELRAXSL4110
220 Vdc RELRAXSL4220
Self reset trip relay with hand reset flag - High burden 4 changeover
110 Vdc RELRAXSH4110
220 Vdc RELRAXSH4220
Schneider Electric RelayAux Reference
RelayAuxType Contacts no. Aux. Supply Relay + Flush mounting socket
Self reset trip relay with hand reset flag - Low burden 8 changeover
110 Vdc RELRAXSL8110
220 Vdc RELRAXSL8220
Self reset trip relay with hand reset flag - High burden 8 changeover
110 Vdc RELRAXSH8110
220 Vdc RELRAXSH8220
ORDER CODES
ORDER CODES
Dimensions (mm) Panel Cut-Out (mm)
DIMENSIONS AND CUT-OUT
Dimensions (mm) Panel Cut-Out (mm)
DIMENSIONS AND CUT-OUT
RelayAuxAccessories for Great Indian Market 14
Order Codes and Dimensions (cont.)
Tripping relays
Schneider Electric RelayAux Reference
RelayAuxType Contacts no. Aux. Supply Relay + Flush mounting socket
Electrical reset trip relay with following flag – Low burden 4 changeover
110 Vdc RELBAXEL4110
220 Vdc RELBAXEL4220
Electrical reset trip relay with following flag – High burden 4 changeover
110 Vdc RELBAXEH4110
220 Vdc RELBAXEH4220
Hand & electrical reset trip relay with following flag – Low burden 4 changeover
110 Vdc RELBAXBL4110
220 Vdc RELBAXBL4220
Hand & electrical reset trip relay with following flag – High burden 4 changeover
110 Vdc RELBAXBH4110
220 Vdc RELBAXBH4220
ORDER CODES
Dimensions (mm) Panel Cut-Out (mm)
DIMENSIONS AND CUT-OUT
RelayAuxAccessories for Great Indian Market 15
Order Codes and Dimensions (cont.)
Tripping relays
ORDER CODES
Dimensions (mm) Panel Cut-Out (mm)
DIMENSIONS AND CUT-OUT
Schneider Electric RelayAux Reference
RelayAuxType Contacts no. Aux. Supply Relay + Flush mounting socket
Electrical reset trip relay with following flag – Low burden 8 changeover
110 Vdc RELBAXEL8110
220 Vdc RELBAXEL8220
Electrical reset trip relay with following flag – High burden 8 changeover
110 Vdc RELBAXEH8110
220 Vdc RELBAXEH8220
Hand & electrical reset trip relay with following flag – Low burden 8 changeover
110 Vdc RELBAXBL8110
220 Vdc RELBAXBL8220
Hand & electrical reset trip relay with following flag – High burden 8 changeover
110 Vdc RELBAXBH8110
220 Vdc RELBAXBH8220
RelayAuxAccessories for Great Indian Market 16
02-2014
© 2
014
Sch
neid
er E
lect
ric In
dust
ries
SA
S -
All
right
s re
serv
ed
As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication.
Design: Schneider Electric Industries SAS - SonovisionPhotos: Schneider Electric Industries SAS Printed: Altavia Connexion - Made in France
NRJED314593EN
This document has been printed on recycled paper.
Schneider Electric Industries SAS
35, rue Joseph Monier CS 30323 F - 92506 Rueil Malmaison Cedex (France)Tel.: +33 (0) 1 41 29 70 00RCS Nanterre 954 503 439 Capital social 896 313 776 €www.schneider-electric.com
ORDER CODES Schneider Electric RelayAux Reference
RelayAuxType Contacts no. Aux. Supply Relay + Flush mounting socket
Trip circuit supervision relay (Three phases circuit breaker) 2 changeover
110 Vdc RELVD9X110
220 Vdc RELVD9X220
Order Codes and Dimensions (cont.)
Supervision relaysSchneider Electric
RelayAux Reference
RelayAuxType Contacts no. Aux. Supply Relay + Flush mounting socket
DC supply supervision relay 4 changeover110 Vdc RELVD1X110
220 Vdc RELVD1X220
Trip circuit supervision relay (Single phase circuit breaker) 2 changeover
110 Vdc RELVD3X110
220 Vdc RELVD3X220
ORDER CODES
Dimensions (mm) Panel Cut-Out (mm)
DIMENSIONS AND CUT-OUT
DIMENSIONS AND CUT-OUT
Dimensions (mm) Panel Cut-Out (mm)