12
CI/SfB (29) Et6 January 2007 Reinforcement Continuity Systems for the Construction Industry

Reinforcement Continuity Systems...Refractory Fixings ISO 9001: 2000 FM 12226 ISO 14001: 2004 EMS 505377 Eazistrip Reinforcement Continuity Systems 4 EAZISTRIP REINFORCEMENT CONTINUITY

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

  • CI/SfB (29) Et6

    January 2007

    ReinforcementContinuity Systemsfor the Construction Industry

  • 2

  • Ancon designs and manufactures high integrity steel products for

    the construction industry. Through continuous programmes of

    new product development, inward investment and employee

    advancement, the company is committed to maintaining the

    highest level of customer service within a dynamic and

    challenging industry.

    The use of reinforcement continuity systems isa widely accepted means of providingcontinuity of reinforcement acrossconstructions joints in concrete.

    Eazistrip Reinforcement Continuity Systems 4Standard Range Configurations 5

    Standard Range Specifications 6-7

    Installation 8

    On-site Cutting 9

    Enquiry/Order Form 10

    Eazistrip Water Stop 11

    Other Ancon Products 11

    3

    Masonry Support Systems

    Windposts and Lintels

    Wall Ties and Restraint Fixings

    Channel and Bolt Fixings

    Tension Systems

    Special Fabrications

    Flooring and Formed Sections

    Shear Load Connectors

    Reinforcing Bar Couplers

    ReinforcementContinuity Systems

    Punching Shear Reinforcement

    Insulated Balcony Connectors

    Refractory Fixings

    ISO 9001: 2000FM 12226

    ISO 14001: 2004EMS 505377

  • Eazistrip Reinforcement Continuity Systems

    4

    EAZISTRIP REINFORCEMENTCONTINUITY SYSTEMS

    The Eazistrip Reinforcement Continuity Systemis a quick and easy to install method ofmaintaining continuity of reinforcement atconstruction joints in concrete. It consists of a galvanised steel casing with a dimpledsurface to provide an effective concrete bond.Pre-bent bars are housed within the casingand are enclosed by a protective cover. Each end of the unit is sealed with apolystyrene block in order to prevent theingress of concrete.

    The complete unit is nailed to the formwork.Alternatively it can be wired back to the mainreinforcement cage. The concrete is then cast.After striking the formwork, the cover isremoved and the bars are straightened, readyfor lapping onto the main reinforcement, usingan Eazistrip re-bending tool.

    The steel casing remains embedded in the walland is filled with concrete when the nextsection is poured, the dimpled surfaceproviding an efficient key.

    QUALITYEazistrip Reinforcement Continuity Systems are manufactured using CARESapproved bar which meets the requirements of BS4449. The grade of reinforcing bar usedis Grade 500B, minimum yield 500N/mm2,minimum uniform elongation Agt 5%.The bars are bent in accordance with BS8666.

    Ancon Building Products is a BS EN ISO9001registered company.

    Use of the Eazistrip system offers manybenefits over conventional joint construction,including the simplification of formwork designand removal of the need to drill shuttering. This contributes to the acceleration of theconstruction process. As the bars remainenclosed within the casing until required, theyare protected and the risk of injury fromprojecting bars is minimised. Easy to use, thesystem requires little on site training in order tocarry out installation.

    The Eazistrip system is potentially suitable foruse in any construction joint in concrete, butthe most commonly found applicationsinclude:

    • Floor slabs• Walls• Stairwells• Corbels• Diaphragm walls• Jumpforms• Brick support ledges

  • Tel: +44 (0) 114 275 5224 Web: www.ancon.co.uk

    5

    Type 140

    1200mm

    170

    60

    60

    30

    170

    90

    110

    30

    170

    170

    190

    30

    170

    220

    240

    When the stirrup width exceeds 220mm, unitswill be supplied as two single overlappinghooks, to be positioned side by side.

    30

    170

    120

    140

    30

    170

    140

    160

    30

    170

    60/72

    80

    30

    170

    96

    110

    30

    150mm*Centres

    200mm*Centres

    Type 160

    Type 190

    1200mm

    Type 240

    Type 80Type 60

    Type 110

    Type 110

    Notes: Units containing 16mm bars are nominally 50mm deep.On 16mm Ø Type U boxes, the stirrup may be achieved usingtwo shape code 21 bars. These are referenced DH.

    *Other centres are available

    STANDARD RANGE CONFIGURATIONS

  • 6

    UK Range Dimensions

    STANDARD RANGE SPECIFICATIONSThe following tables give details of the Eazistripstandard ranges. Many customers requirepurpose made units to suit their particularapplication. In order to meet this requirementAncon will manufacture according to yourspecific bar arrangement. The most commonshapes are shown on page 10. For furtherdetails please contact Ancon Building Products.

    Part No. Box Width Box Rebar Dia Centres Stirrup Stirrup Legmm Length mm mm mm Height mm Width mm Length mm Bars / Box

    EZ 60H 10/150 60 1200 10 150 170 60 410 8

    EZ 60H 10/200 60 1200 10 200 170 60 410 6

    EZ 80H 10/150 80 1200 10 150 170 60 410 8

    EZ 80H 10/200 80 1200 10 200 170 60 410 6

    EZ 80H 12/150 80 1200 12 150 170 80 500 8

    EZ 80H 12/200 80 1200 12 200 170 80 500 6

    EZ 110U 10/150 110 1200 10 150 170 90 410 8

    EZ 110U 10/200 110 1200 10 200 170 90 410 6

    EZ 110U 12/200 110 1200 12 200 170 90 500 6

    EZ 140U 10/150 140 1200 10 150 170 120 410 8

    EZ 140U 10/200 140 1200 10 200 170 120 410 6

    EZ 140U 12/150 140 1200 12 150 170 120 500 8

    EZ 140U 12/200 140 1200 12 200 170 120 500 6

    EZ 160U 10/150 160 1200 10 150 170 140 410 8

    EZ 160U 10/200 160 1200 10 200 170 140 410 6

    EZ 160U 12/150 160 1200 12 150 170 140 500 8

    EZ 160U 12/200 160 1200 12 200 170 140 500 6

    EZ 190U 10/150 190 1200 10 150 170 170 410 8

    EZ 190U 10/200 190 1200 10 200 170 170 410 6

    EZ 190U 12/150 190 1200 12 150 170 170 500 8

    EZ 190U 12/200 190 1200 12 200 170 170 500 6

    EZ 190DH 16/150 190 1200 16 150 170 170 650 8

    EZ 190U 16/200 190 1200 16 200 170 170 650 6

    EZ 240U 10/150 240 1200 10 150 170 220 410 8

    EZ 240U 10/200 240 1200 10 200 170 220 410 6

    EZ 240U 12/150 240 1200 12 150 170 220 500 8

    EZ 240U 12/200 240 1200 12 200 170 220 500 6

    EZ 240U 16/150 240 1200 16 150 170 220 650 8

    EZ 240U 16/200 240 1200 16 200 170 220 650 6

    Notes: Dimensions shown in the above table are nominal. Heights and lengths may typically vary by one bar diameter. Maximum box length is 3m dependant upon weight.

    h l

    b

    w

    h

    b

    d

    U TYPE BOX DIMENSIONS

    Eazistrip Reinforcement Continuity Systems

  • Tel: +44 (0) 114 275 5224 Web: www.ancon.co.uk

    7

    Continental Range Dimensions

    Part No. Box Width Box Rebar Dia Centres Stirrup Stirrup Legmm Length mm mm mm Height mm Width mm Length mm Bars / Box

    EZ 60H 10/150 60 1200 10 150 155 60 340 8

    EZ 60H 10/200 60 1200 10 200 155 60 340 6

    EZ 80H 10/150 80 1200 10 150 155 60 340 8

    EZ 80H 10/200 80 1200 10 200 155 60 340 6

    EZ 80H 12/150 80 1200 12 150 155 80 405 8

    EZ 80H 12/200 80 1200 12 200 155 80 405 6

    EZ 110H 16/150 110 1200 16 150 155 96 575 8

    EZ 110H16/200 110 1200 16 200 155 96 575 6

    EZ 110U 10/150 110 1200 10 150 155 90 340 8

    EZ 110U 10/200 110 1200 10 200 155 90 340 6

    EZ 110U 12/150 110 1200 12 150 155 90 340 8

    EZ 110U 12/200 110 1200 12 200 155 90 405 6

    EZ 140U 10/150 140 1200 10 150 155 120 340 8

    EZ 140U 10/200 140 1200 10 200 155 120 340 6

    EZ 140U 12/150 140 1200 12 150 155 120 405 8

    EZ 140U 12/200 140 1200 12 200 155 120 405 6

    EZ 160U 10/150 160 1200 10 150 155 140 340 8

    EZ 160U 10/200 160 1200 10 200 155 140 340 6

    EZ 160U 12/150 160 1200 12 150 155 140 405 8

    EZ 160U 12/200 160 1200 12 200 155 140 405 6

    EZ 160DH 16/150 160 1200 16 150 160 140 410 8

    EZ 160DH 16/200 160 1200 16 200 160 140 410 6

    EZ 190U 10/150 190 1200 10 150 155 170 340 8

    EZ 190U 10/200 190 1200 10 200 155 170 340 6

    EZ 190U 12/150 190 1200 12 150 155 170 405 8

    EZ 190U 12/200 190 1200 12 200 155 170 405 6

    EZ 190DH 16/150 190 1200 16 150 160 170 575 8

    EZ 190U 16/200 190 1200 16 200 160 170 650 6

    EZ 240U 10/150 240 1200 10 150 155 220 340 8

    EZ 240U 10/200 240 1200 10 200 155 220 340 6

    EZ 240U 12/150 240 1200 12 150 155 220 500 8

    EZ 240U 12/200 240 1200 12 200 155 220 500 6

    EZ 240U 16/150 240 1200 16 150 160 220 650 8

    EZ 240U 16/200 240 1200 16 200 160 220 650 6

    Notes: Dimensions shown in the above table are nominal. Heights and lengths may typically vary by one bar diameter. Maximum box length is 3m dependant upon weight.

    RADIUSED EAZISTRIPMany of the units detailed in the brochure areavailable radiused. Please contact Ancon withyour requirements.

  • 8

    Nail the Eazistrip through the casing to theformwork or alternatively securely tie theprojecting anchorage reinforcing bars back tothe main reinforcement. In both cases theEazistrip box should be securely fixed to avoiddisplacement during concreting. The casingshould be tight against the formwork. Pourconcrete.

    Strike the formwork to reveal the steel cover.

    Remove the steel cover to expose thepre-bent bars.

    Straighten the bars using the appropriate sizedAncon Eazistrip re-bending tool for the size ofbar. The bars should be straightened onlyonce. To avoid damage to adjacent concrete,it is prudent to allow a concrete curing periodof seven days. See ‘Bar Straightening’ formore information.

    Once the bars are straightened and alignedthey are ready for lapping with the concreteelement reinforcement, provided by others.

    INSTALLATION BAR STRAIGHTENINGThe bars in the Eazistrip box must bestraightened using the appropriate sizedAncon Eazistrip re-bending tool. This is a steeltube designed to fit over the bar, the internaldiameter being slightly larger than themaximum dimension over the ribs of the bar.One end of the tube has a section cut away;this provides support to the outside of thebend during straightening of the bar and limitsthe point contact of the tube on the bar.

    Use of the tool allows the re-bending processto be carried out in a smooth continuousaction (avoiding jerky action), the tube beingmoved along the bar and around the bend asit is straightened. Scaffold tubes or similarmust not be used to straighten bar.

    To enable the re-bending tool to be fitted ontothe bar, the bar should be pulled the minimumdistance from the Eazistrip steel casing toenable this. The re-bending tool should thenbe slid along the bar to the start of the bendradius.

    The bar straightening process should besmooth and progressive with the tube allowedto move along the bend towards the metalcasing as it is straightened. The tool shouldcontact the Eazistrip steel casing at thecompletion of the straightening process.

    The tube is then removed and the straightenedbar checked for alignment and cover with theadjoining reinforcement.

    The Eazistrip reinforcing bars should not bestraightened when the temperature of the steelis below 5°C. Where straightening is necessarybelow 5°C, indirect warming of the steel to atemperature not exceeding 100°C is permitted.

    The use of scaffold tubes, or otherinappropriate tools will result in excessive kinksin the region of the bar bend and result inundesirable work hardening which maydamage the bar and affect the strength of thebar. Re-bending must be undertaken usingonly the Ancon Eazistrip re-bending tool.Bending the bar in excess of therecommendations will also result in workhardening of the rebar and should therefore beavoided.

    1 4

    52

    3

    Eazistrip Reinforcement Continuity Systems

  • Tel: +44 (0) 114 275 5224 Web: www.ancon.co.uk

    9

    Identify the location of the intended cut.

    ON-SITE CUTTING

    1

    Slide the protective cover from the box and remove the bars which pass over the cut location.

    2

    Cut through the steel casing using a disc cutter.

    3

    Replace the bars to face the opposite direction to their original position. Cut the cover to the samelengths as the steel casing and replace to protect the bars. The ends of the boxes must besealed, using polystyrene blocks, to prevent the ingress of concrete

    Note: Protective gloves should be worn when removing covers, straightening bars, cutting boxes and during general handling of Eazistrip.

    4

  • Type 2H Double Hook (not available in 60mm and 80mm box)

    10

    ENQUIRY/ORDER FORM

    Please photocopy this page and use it to detail your enquiry/order.

    Item Qty Box Bar Dia Stirrup Stirrup Box Stirrup Stirrup Anchoring StirrupWidth (1) 10, 12, 16 Spacing (2) Type Length (3) Width (4) Height Length Width (5)

    b h l c(mm) (mm) (mm) (see above) (mm) (mm) (mm) (mm) (mm)

    Re-bending Tool

    Type RA3 Double AngleType RA1 Double Angle

    Type RA Angle

    Type H Hook (standard in 60mm and 80mm box)

    Type S Straight Bar

    Type U U Bar Type RU U Bar

    Type S2 Double Straight Bar Type SH Angle with leg inhorizontal plane

    Type RA2 Double Angle

    (1) Standard box widths 60, 80, 110, 140, 160, 190 and 240mm.

    (2) Variable stirrup spacing available. Standard spacing 150 and 200mm.

    (3) Box lengths up to 3000mm available in certain sizes dependant upon weight. Standard length 1200mm.

    (4) Stirrup width b is 20mm less than box width as standard. Special spacing for all types available on request.

    (5) For types RA1, RA2 and RA3, please state dimension c.

    Note: Bars must be straightened using an Eazistrip re-bending tool. Do not straighten bars more than once.

    Date ❒ Order ❒ Enquiry

    Company

    Address

    Town Post Code

    Contact

    Tel Fax

    Email

    Delivery Date

    Delivery Address

    Town Post Code

    Contact

    Tel Fax

    Project

    Email

    h l

    h l

    h

    b

    l

    h

    b

    l

    h

    b c c c

    b

    l h

    b

    b

    lh

    b

    b

    l

    h

    b

    l

    h

    b

    l

    h

    b

    l

    h

    b

    l

    Eazistrip Reinforcement Continuity Systems

  • Tel: +44 (0) 114 275 5224 Web: www.ancon.co.uk

    11

    OTHER ANCON PRODUCTS

    Reinforcing Bar CouplersThe use of reinforcing bar couplers canprovide significant advantages over lappedjoints. Design and construction of the concretecan be simplified and the amount ofreinforcement required can be reduced.The range includes threaded and mechanicallybolted couplers.

    Shear Load ConnectorsAncon DSD and ESD Shear Load Connectorsare used to transfer shear across expansionand contraction joints in concrete. They aremore effective at transferring load and allowingmovement to take place than standard dowels,and can be used to eliminate double columnsat structural movement joints in buildings.

    Channel and Bolt FixingsAncon offers a wide range of channels andbolts in order to fix stainless steel masonrysupport, restraints and windposts to structuralframes. Cast-in channels and expansion boltsare used for fixing to the edges of concretefloors and beams.

    Insulated Balcony ConnectorsAncon Isolan connectors join external concretebalconies to internal floor slabs. Used tominimise cold bridging, they provide continuityto the thermal insulation. Standard systems,comprising rigid CFC-free polystyrene insulationand duplex stainless steel shear reinforcement,suit most depths of cantilevered and simplysupported balconies. Conventional reinforcingbars are used to provide the tension andcompression reinforcement.

    Punching Shear ReinforcementUsed within a slab to provide additionalreinforcement around columns, Ancon Shearfixis the ideal solution to the design andconstruction problems associated withpunching shear. The system consists ofdouble-headed studs welded to flat rails,positioned in a symmetrical pattern around thecolumn head. The shear load from the slab istransferred through the studs into the column.

    Special Stainless Steel FabricationsAncon has a wealth of experience in workingwith different types and grades of stainlesssteel. Advanced manufacturing facilities enableone-off or volume orders to be fabricated toindividual project requirements and to exactingquality standards. Considerable materialstocks are maintained in order to meet urgentdelivery deadlines.

    EAZISTRIP WATER STOP

    Where the potential for water ingress throughthe construction joint is a major concern,Eazistrip can be supplied with a Pentaflexhydrostatic seal. The seal is factory fitted insideand outside the box to provide double sidedprotection against water or moisturepermeation along the joint face.

    As Pentaflex is a hydrostatic seal, it is notreliant on expansion, unlike hydrophilic typeseals, and it provides a continuous elastic sealby means of the bond between the Pentaflexand the fresh concrete. Resistant to organicwaste water, Pentaflex has been tested by theHygiene-Institut, Geisenkirchen, Germany foruse with potable water.

    A protective film on the Pentaflex preventscontamination by dust or dirt during storage,handling and installation. The film must beremoved prior to concreting. When installingand abutting boxes, joints are achieved bypressing together a 50mm overlap of thePentaflex material, to ensure continuousprotection against water permeation.

  • © Ancon Building Products 2003

    The construction applications and details provided in this literatureare indicative only. In every case, project working details should beentrusted to appropriately qualified and experienced persons.

    Whilst every care has been exercised in the preparation of thisdocument to ensure that any advice, recommendations orinformation is accurate, no liability or responsibility of any kind isaccepted in respect of Ancon Building Products.

    With a policy of continuous product development Ancon BuildingProducts reserves the right to modify product design andspecification without due notice.

    These products are available from:

    Ancon Building ProductsPresident Way, President ParkSheffield S4 7URUnited KingdomTel: +44 (0) 114 275 5224Fax: +44 (0) 114 276 8543Email: [email protected]: www.ancon.co.uk

    Ancon (Middle East) FZEPO Box 17225Jebel AliDubaiUnited Arab EmiratesTel: +971 (0) 4 883 4346Fax: +971 (0) 4 883 4347Email: [email protected]

    Ancon Building Products114 Kurrajong AvenueMount DruittSydneyNSW 2770AustraliaTel: +61 (0) 2 9675 1000Fax: +61 (0) 2 9675 3390Email: [email protected]: www.anconbp.com.au

    Ancon (Schweiz) AGGewerbezone Widalmi 103216 Ried bei KerzersSwitzerlandTel: +41 (0) 31 750 3030Fax: +41 (0) 31 750 3033 Email: [email protected]: www.ancon.ch

    Ancon Building Products GesmbHGerspergasse 9/3 Top 1A-1210 ViennaAustriaTel: +43 (0) 1 259 58 62-0Fax: +43 (0) 1 259 58 62-40Email: [email protected]: www.ancon.at

    Ancon GmbHBartholomäusstrasse 2690489 NurembergGermanyTel: +49 (0) 911 955 1234 0Fax: +49 (0) 911 955 1234 9Email: [email protected]: www.anconbp.de

    ISO 9001: 2000FM 12226

    ISO 14001: 2004EMS 505377

    EAZISTRIP REINFORCEMENTQUALITYSTANDARD RANGE CONFIGURATIONSSTANDARD RANGE SPECIFICATIONSU TYPE BOX DIMENSIONSUK Range DimensionsContinental Range DimensionsRADIUSED EAZISTRIPINSTALLATIONBAR STRAIGHTENINGON-SITE CUTTINGENQUIRY/ORDER FORMEAZISTRIP WATER STOPOTHER ANCON PRODUCTS