B101a
0
#
#
SIM
A101
1SIM
DEPT.#
#
ADD
GRID LINES
SECTIONS
DETAIL NUMBER
SHEET NUMBER
DETAIL NUMBER
SHEET NUMBER
DETAILS IN PLAN/SECTION
ROOM NUMBER
DOOR NO. ON PLAN
H.M. FRAME NO. ON PLAN
REVISION: TYPE = A.S.I/P.R./C.C.D./ADD.
CASEWORK(FURNISHING PLANS ONLY)
ALUM. FRAME/WINDOW TYPE
WALL TYPE
#-#.#
#
#
# # INTERIOR ELEVATION
DETAIL NUMBER
SHEET NUMBER
A3
ROOM NAME
B101a
##
EARTH
GRAVEL
CONCRETE
CONCRETE MASONRY UNITS
SOLID CONCRETE MASONRY UNITS
BRICK
WOOD-FINISHED
WOOD ROUGH
PLYWOOD
GYPSUM BOARD
ACOUSTIC TILE
STEEL - LARGE SCALE
CAST STONE
ALL METALS - SMALL SCALE
GLASS - LARGE SCALE
BATT INSULATION
RIGID INSULATION
CERAMIC TILE
CARPET
Above finished floor AFFAcoustic ACSTAcoustic Panel Ceiling APCAddendum ADDAlternate ALTAluminum ALAngle LApproximate APPROXArchitecture, architectural ARCHAsbestos ASBAsphalt ASPHAssistant ASSTAssociation ASSNAutomatic AUTOAverage AVGBase plate BP Basement BSMTBeam BMBearing BRGBedroom BRBenchmark BMBoard BDBoiler BLRBottom BOTBrick BRKBuilding line BLBuilding BLDGBuilt-up-roof BURCabinet CABCarpet CPTCatalog CATCeiling height CHCeiling CLGCenter CTRCenterline CLCeramic Tile CTCeramic CERChalkboard CBClear CLRCloset CLOCoated CTDCold rolled CRColumn COLCompany COComposition COMPConcrete Masonry Unit CMUConcrete CONCConstruction joint CJConstruction CONSTR"Continue, Continuous" CONTCorridor CORRCountersink CSKCubic CUCurve(d) CRVDampproofing DPDegree DEGDepartment(al) DEPTDetail DETDiagonal DIAGDiameter DIADimension DIMDishwasher DWDispenser DISPDoor DRDouble DBLDouble-hung DHDown DNDownspout DSDrain DRDrawing DWGEach EAEast EElectric Water Cooler EWC"Electric, electrical" ELECElevation ELElevator ELEVEngineer ENGREntrance ENTREqual EQEquipment EQUIPExhaust EXHExisting EXISTExpansion joint EXP JTExposed EXPExterior EXTFabricate FABFace of Stud F. OF S.Fan Coil Unit FCUFiberglass-reinforced plastics FRPFinish FINFinished Floor FFFire Extinguisher FEFire Extinguisher & Cabinet FECFire Retardant Treated FRTFireproof FPRFFixture FXTRFlange FLGFlashing FLFloor FLFloor drain FDFlooring FLGFluorescent FLUOR
Footing FTGFoundation FDNFurnish(ed), furniture FURNFurring FURRGage (gauge) GAGalvanize(d) GALVGalvanized Iron GALVIGlazed Wall Tile GWTGrab Bar GBGrade GRGravel GVLGypsum Wallboard GWBGypsum GYPHandicapped HCHardware HDWHeating ventilating and HVACair conditioningHeight HGTHigh Point HPTHigh Performance HPHigh Performance Coating HPCHollow Metal HMHorizontal HORIZInclude(d), inclusive INCLIncorporated INCInformation INFOInside diameter IDInstall(ed), installation INSTLInsulation INSULInterior INTJanitor JANJoint JTJoist J, JSTJunction box JBKnock down KDLaboratory LABLavatory LAVLeft Hand LHLeft LLength LGLevel LVLLight LTMachine MACHMaintenance MAINTManager MGRManual MNLManufacturing MFGMarkerboard MBMasonry opening MOMasonry MSNRYMaster bedroom MBRMaterial MATLMaximum MAXMechanical MECHMembrane MEMBMen MMetal MET, MTLMezzanine MEZZMinimum MINMirror MIRMiscellaneous MISCMounted MTDMounting MTGNecessary NECNoise-reduction coefficient NRCNominal NOMNon Combustible NC, NONCOMNorth NNot in Contract NICNot to scale NTSNot available NANumber NOOffice OFFOn center OCOpening OPNGOpposite OPPOutside diameter ODOverall OAOverhead OVHDPage PPainted PTDPair PRPanel PNLPartition PTNPercent PCTPerforate(d) PERFPermanent PERMPerpendicular PERPPiece PCPlastic Laminate PLAMPlastic Laminate PLAS.LAMPlate PLPlumbing PLMBPlywood PLYWDPoint PTPolyvinyl chloride PVCPrecast PRCSTPrefabricated PREFABPreliminary PRELIMPreparation, prepare PREPProgram PRGMProjection Screen PS
Project PROJProperty PROPPublic Address PAQuality control QCQuality QUALQuantity QTYQuarry Tile QTRadius RADRain Leader RLReceived RCVDReceptacle RCPTReceptionist RECPTRecess(ed) RECRefer, reference REFRefrigerate, refrigerator REFRReinforce REINFReinforced concrete RCRemove RMVRepair RPRRequired REQDRevise, revision REVRight hand RHRoad RDRoof Drain RDRoof RFRoofing RFGRoom RMRubber tile floor RTFRubber RBRSchedule SCHEDSchematic SCHEMSection SECTService SVCE"Sheet, sheeting" SHTShower SHSiding SDGSimilar SIMSlope SLSound-transmission class STCSouth SSpeaker SPKRSpecification SPECSprinkler SPRSquare SQStainless steel SSStandard STDStandpipe SPSteel STLStorage STORStructural Glazed Facing Tile SGFTStructural, structure STRUCTSubstitute SUBSTSurface SURFSuspend(ed) SUSPSwitch SWSymmetrical SYMSystem SYSTackboard TBTackstrip TSTelephone TELTelevision TVTemporary TEMPTerrazzo TERThick THKThrough THRUToilet TTongue and groove T>op and bottom T&BTop chord TCTop of Masonry Parapet TMPTop of Bearing TOFBTop of Steel T.O.S.Topping TOPGTotal TOTTransformer XFMRTransom TRTransparent TRANSTread TRDThreshold THRESHTypical TYPUnderground UGUnderwriters Laboratories ULUnfinished UNFUnit Ventilator UVUnless Otherwise Noted UONUrinal URUS Gypsum Company USGVertical VERTVestibule VEST, VVinyl Reducing Strip VRSVinyl Composite Tile VCTVinyl asbestos tile VATWardrobe WARDWater closet WCWaterproof WPWeight WTWelded WLDWelded Wire Mesh WWMWith W/Without W/OWomen WWood WDWrought Iron WI
BASE BID: COLD FORM STEEL STUDS, EXTERIOR GRADE SHEATHING, FOAMED IN PLACEINSULATION WITH 4” THICK, 16” HIGH X 24” MASONRY VENEER UNITS. REFERENCE UNIT MASONRY SPECIFICATION SECTION 04 20 00. THE EXTERIOR STAIR IS CMU BACKUP WITH 4” THICK, 16” HIGH X 24” MASONRY VENEER UNITS REFERENCE SPECIFICATIONS AND DETAILS.
ALTERNATE 1S: STUCCO FINISH ON 5/8” CEMENT BACKERBOARD ATTACHED TO 4” COMPOSITE GIRTS INFILLED WITH 4” RIGID POLY STYRENE INSULATION. ARCHITECT TO SELECT FINISH FROM MANUFACTURER’S STANDARD SELECTIONS. REFERENCE CEMENT PLASTERING SPECIFICATION SECTION 09 24 00.
ALTERNATES
123456789101112131415161718
11720 B
eltsvill
e D
rive
Suite 6
00
Calv
ert
on,
MD
20705
Tel: 3
01.5
95.1
000
123456789101112131415161718
A
B
C
D
E
F
G
H
J
K
L
M
A
B
C
D
E
F
G
H
J
K
L
M
© GRIMM AND PARKER ARCHITECTURE, INC.
© GRIMM AND PARKER ARCHITECTURE, INC.
ww
w.g
rim
mandpark
er.
com
PROFESSIONAL CERTIFICATION
I CERTIFY THAT THESE DOCUMENTS
WERE PREPARED OR APPROVED BY
ME, AND I AM A DULY LICENSED
ARCHITECT UNDER THE STATE OF
DELAWARE,
LICENSE NUMBER# 8570
EXPIRATION: 1/31/2022
TSS
TITL
E S
HE
ET
REHO
BOTH
SPO
TLIG
HT IN
C.41
7 REH
OBOT
H AV
E RE
HOBO
TH B
EACH
, DE
1997
1
4/17/2020PERMIT SUBMISSION
GP #21828.00OWNER
D E S I G N T E A M
REHOBOTH SPOTLIGHT INC.
417 REHOBOTH AVE REHOBOTH
BEACH, DE 19971
PERMIT SUBMISSION
4/17/2020
DRAWING KEY
SYMBOLS OF MATERIALS
ABBREVIATIONS
GRIMM + PARKER
MERESTONE CONSULTANTS
GIPE ASSOCIATES
PILOTTOWN
ARCHITECT
CIVIL ENGINEER/ SURVEYOR
MECH,ELECT,FP,PLMG ENGINEER
STRUCTURAL ENGINEER
11720 BELTSVILLE DR., SUITE 600CALVERTON, MD 20705
(301) 595-1000
(302) 226-5880
(410) 822-8688
(302) 703-1770
33516 CROSSING AVE. UNIT 1LEWES, DE 19958
8719 BROOKS DR.EASTON, MD 21601
17585 NASSAU COMMONS BLVD UNIT 3LEWES, DE 19958
GEO-TECHNOLOGY ASSOCIATES GEOTECHNICAL ENGINEER (302) 855-976121113 STERLING AVE. UNIT 7GEORGETOWN, DE 19947
THRESHOLD ACOUSTICS ACOUSTICIAN/ AV (312) 386-1400141 WEST JACKSON BLVD SUITE 200CHICAGO, IL 60604
REHOBOTH SPOTLIGHT INC. (302) 227-227020 BALTIMORE AVEREHOBOTH BEACH, DE 19971
SITE
LOCATION MAP
Rehoboth Ave
DATE DESCRIPTION
CO
NS
OLI
DA
TE
D P
ER
MIT
SE
T 5
/12/
2020
:S
ITE
PLA
N, A
RC
HIT
EC
TU
RA
L P
LAN
S,
SE
CT
ION
S A
ND
ELE
VA
TIO
NS
.*N
OT
FO
R C
ON
ST
RU
CT
ION
*
PARCEL I.D. NO. * 334-13.20-164.00, 165.00, & 166.00
DEED REFERENCE * PARCELS 334-13.20-164.00 & 165.00 PARCEL 334-13.20-166.00
DB 5181, PG 239 DB 5181, PG 235
PLAT REFERENCE * PB 0, PG 0
EXISTING ZONING DISTRICT * C-1 (CENTRAL COMMERCIAL)
SEWAGE DISPOSAL * CITY OF REHOBOTH BEACH
SEWERAGE IS SUBJECT TO APPROVAL OF THE CITY OF REHOBOTH BEACH, THE
DELAWARE STATE DEPARTMENT OF NATURAL RESOURCES AND ENVIRONMENTAL
CONTROL.
WATER SUPPLY * CITY OF REHOBOTH BEACH
WATER IS SUBJECT TO THE APPROVAL OF THE CITY OF REHOBOTH BEACH, DELAWARE
STATE DEPARTMENT OF NATURAL RESOURCES AND ENVIRONMENTAL CONTROL AND THE
DELAWARE DIVISION OF PUBLIC HEALTH.
WATERSHED * LEWES & REHOBOTH CANAL
OWNER/DEVELOPER * PARCELS 334-13.20-164.00 & 165.00 PARCEL 334-13.20-166.00
CLEAR SPACE THEATRE COMPANY REHOBOTH SPOTLIGHT, INC.
C/O WESLEY PAULSON C/O WESLEY PAULSON
20 BALTIMORE AVENUE 20 BALTIMORE AVENUE
REHOBOTH BEACH, DE 19971 REHOBOTH BEACH, DE 19971
PHONE: 240-593-4090 PHONE: 240-593-4090
HORIZONTAL DATUM * NAD 83 (NA 2011, EPOCH 2010)
VERTICAL DATUM * NAVD '88
EXISTING USE * VACANT
NO. OF LOTS * 3 EXISTING, 2 PROPOSED
PARCEL AREA * 15,000 S.F.
SITE ADDRESS * 415 & 417 REHOBOTH AVENUE
LOCATION MAP SCALE: 1"= 1,000'
SITE
8NUMBER OF PARKING STALLS IN ROW
HANDICAP MARKER
SITE LIGHT
REBAR FOUND
RIGHT-OF-WAY LINE
PROPERTY LINE
BUILDING SETBACK LINE
TREELINE
FIRE DEPARTMENT CONNECTION
PROPOSEDEXISTING
UNDERGROUND ELECTRIC
SPOT ELEVATIONS
CONTOUR
STORM SEWER
WATER LINE
SANITARY SEWER
8
HYDRANT
SS
MH
W
S
C.B.
X (18.50)
15''RCP 15''RCP
IRON PIPE FOUND
SANITARY CLEANOUT
CO
SIGN
EASEMENT LINE
CENTERLINE
CONCRETE MONUMENT FOUND
SOIL BORING
WETLAND DELINEATION LINE
EROSION & SEDIMENT CONTROL LEGEND
GAS LINE GAS GAS
GRAVEL DRIVEWAY
CLAM SHELL DRIVEWAY
CONCRETE
HANDICAP PARKING SIGN
PAVERS
UNDERGROUND TELEPHONE
UNDERGROUND TELEPHONE
VINYL PRIVACY FENCE
X X XWOOD PRIVACY FENCE
TRANSFORMER
PARKING METER
WATER METER
A
BUILDING DESIGNATION
1. THE PERIMETER BOUNDARY FOR THIS PROJECT, PREPARED BY ATLANTIC GROUP & ASSOCIATES, INC., IS
SHOWN ON A BOUNDARY SURVEY PLAN, DATED 8/15/18. MERESTONE CONSULTANTS, INC. HAS PROVIDED
LOCATIONS OF PHYSICAL FEATURES, UTILITIES AND A TOPOGRAPHIC SURVEY.
2. BASIS OF BEARING: NAD 83(2011) Epoch 2010.00, DELAWARE STATE PLANE
3. THE SITE IS LOCATED WITHIN ZONE "X", AREA OF MINIMAL FLOOD HAZARD AS DESIGNATED ON THE FLOOD
INSURANCE RATE MAP NUMBER 1005C0354K LAST REVISED MARCH 16th, 2015.
4. COPYRIGHT © 2019. MERESTONE CONSULTANTS, INC. ALL RIGHTS RESERVED. NO PART OF THIS DRAWING
MAY BE REPRODUCED BY PHOTOCOPYING, RECORDING OR BY ANY OTHER MEANS, OR STORED,
PROCESSED, OR TRANSMITTED IN OR BY ANY COMPUTER OR OTHER SYSTEMS WITHOUT THE PRIOR
WRITTEN PERMISSION OF MERESTONE CONSULTANTS, INC. COPIES OF THIS PLAN WITHOUT COLORED INK
SIGNATURE AND A RAISED IMPRESSION SEAL ARE NOT VALID.
5. THE LOCATIONS OF UNDERGROUND UTILITIES ARE PROVIDED USING THE BEST AVAILABLE INFORMATION
WHICH INCLUDES FIELD LOCATIONS OF VISIBLE FEATURES AND REVIEW OF REHOBOTH AVENUE
STREETSCAPE IMPROVEMENTS, PHASE 2 (CONTRACT NO. 2003-8).
PROFESSIONAL ENGINEER (DE #7842)
APPROVED: DATE:
N
A
D
8
3
(
2
0
1
1
)
E
p
o
c
h
2
0
1
0
.
0
0
DRAWN BY: DATE: PROJECT:
5215 WEST WOODMILL DRIVE
WILMINGTON, DE 19808
PH: 302-992-7900
FAX: 302-992-7911
35516 CROSSING AVENUE, UNIT 1
FIVE POINTS SQUARE
LEWES, DE 19958
PH: 302-226-5880
7 JANUARY 2020
11720 B
eltsville D
rive
Suite 600
Calverton, M
D 20705
Tel: 301.595.1000
ww
w.grim
mandparker.com
DATE DESCRIPTION
24718LRAG
R:\P
ro
je
cts\24718L C
le
ar S
pace T
heater\D
WG
\2
47
18
L-S
urvey.dw
g, 4/2
0/20
20
12
:44
:0
1 P
M, D
WG
T
o P
DF
.pc3
S
CO
NS
OLI
DA
TE
D P
ER
MIT
SE
T 5
/12/
2020
:S
ITE
PLA
N, A
RC
HIT
EC
TU
RA
L P
LAN
S,
SE
CT
ION
S A
ND
ELE
VA
TIO
NS
.*N
OT
FO
R C
ON
ST
RU
CT
ION
*
PARCEL I.D. NO. * 334-13.20-166.00
DEED REFERENCE * DB 5181, PG 235
PLAT REFERENCE * PB 0, PG 0
EXISTING ZONING DISTRICT * C-1 (CENTRAL COMMERCIAL)
PROPOSED ZONING DISTRICT * C-1 (CENTRAL COMMERCIAL)
SEWAGE DISPOSAL * CITY OF REHOBOTH BEACH
SEWERAGE IS SUBJECT TO APPROVAL OF THE CITY OF REHOBOTH BEACH, THE
DELAWARE STATE DEPARTMENT OF NATURAL RESOURCES AND ENVIRONMENTAL
CONTROL.
WATER SUPPLY * CITY OF REHOBOTH BEACH
WATER IS SUBJECT TO THE APPROVAL OF THE CITY OF REHOBOTH BEACH, DELAWARE
STATE DEPARTMENT OF NATURAL RESOURCES AND ENVIRONMENTAL CONTROL AND THE
DELAWARE DIVISION OF PUBLIC HEALTH.
WATERSHED * LEWES & REHOBOTH CANAL
OWNER/DEVELOPER * REHOBOTH SPOTLIGHT, INC.
C/O WESLEY PAULSON
20 BALTIMORE AVENUE
REHOBOTH BEACH, DE 19971
PHONE: 240-593-4090
LOCAL LAND USE AGENCY * CITY OF REHOBOTH BEACH PLANNING COMMISSION
HORIZONTAL DATUM * NAD 83 (NA 2011, EPOCH 2010)
VERTICAL DATUM * NAVD '88
EXISTING USE * _
PROPOSED USE * THEATRE/ASSEMBLY
NO. OF LOTS * 1 EXISTING
LOT AREA RATIONALE * GROSS AREA (S.F.) 5,000
RIGHT-OF-WAY DEDICATION (S.F.) N/A
NET ARE (USED FOR CALCULATIONS) (S.F.) 5,000
AREA (S.F.)
BUILDING AREA 3,551 (71.0%)
IMPERVIOUS AREAS 840 (16.8%)
OPEN SPACE AREA 609 (12.2%)
HEIGHT, AREA & BULK TABLE * MAX. BUILDING HEIGHT (FT.)= 42 (3 STORIES)
(SCREENED HVAC PERMITTED ON ROOF)
MAX. (FLOOR AREA RATIO (FAR)= 2.0 x LOT AREA
MAX. LOT COVERAGE (%)= 100 (MINUS REQUIRED REAR YARD)
MINIMUM LOT SIZE (S.F.) = 5,000
MINIMUM LOT WIDTH (FT.) = 50
MINIMUM LOT DEPTH (FT.) = 100 (1)
MINIMUM FRONT YARD (FT.) = NONE
MINIMUM SIDE YARD (FT.) = NONE (2)
MINIMUM REAR YARD (FT.) = NONE (2)
1. In all commercial districts, for any building or structure not required to have a setback of at least
10 feet, all portions or floors thereof which face any street or the Boardwalk, except Rehoboth
Avenue, shall, beginning not higher than 14 feet vertically above the setback line or lines for the
lot or lots involved, be constructed or placed to the rear of an angled stepback line which slants
away from the street, streets or boardwalk at an angle of not less than 30° in magnitude from a
vertical line above the setback line or lines, with the vertex of such angle fixed at a point not
higher than 14 feet above the setback line or lines. The stepback line of buildings or structures
facing Rehoboth Avenue shall begin at 24 feet.
2. Where the boundary line dividing a commercial and residential district is a rear or side property
line, there shall be a rear or side yard on the lot in the commercial district of at least five feet.
The rear or side yard of the lot in the commercial district shall be bounded by a screen in order
to shield or obscure the lot from those in the abutting residential district.
PARKING RATIONALE * NONE REQUIRED (BUILDING GFA < 15,000 S.F.)
INVESTMENT LEVEL AREA * INVESTMENT LEVEL 1
HIGHWAY MAINTENANCE NO. * S 15
POSTED SPEED LIMIT * 35 MPH
FIRE MARSHALL NOTES * N.F.P.A BUILDING TYPE = TYPE:II-000 (NON-COMBUSTIBLE)
FIRE SUPPRESSION= AUTOMATIC SPRINKLERS ARE PROPOSED
MAX. BUILDING HEIGHT (H) < 42'
A. AN AUTOMATIC FIRE ALARM SYSTEM AND SIGNALING SYSTEM PLANS AND
SPECIFICATIONS SHALL BE SUBMITTED FOR REVIEW PER DSFPR FIRE REGULATION
702, CHAPTER 6, SECTION 3.
B. A LOCK BOX IS REQUIRED; CONTACT LOCAL FIRE CHIEF FOR ORDERING
INFORMATION AND LOCATION OF BOX ON THE BUILDING.
SITE ADDRESS * 417 REHOBOTH AVENUE
LOCATION MAP SCALE: 1"= 1,000'
SITE
I, ROGER A. GROSS, P.E. HEREBY CERTIFY THAT I AM A REGISTERED PROFESSIONAL
ENGINEER IN THE STATE OF DELAWARE, AND THAT THE INFORMATION SHOWN HEREON
HAS BEEN PREPARED UNDER MY SUPERVISION AND TO THE BEST OF MY KNOWLEDGE AND
BELIEF REPRESENTS GOOD ENGINEERING PRACTICES AS REQUIRED BY THE APPLICABLE
LAWS OF THE STATE OF DELAWARE.
ROGER A. GROSS, P.E. DATE:
MERESTONE CONSULTANTS, INC.
33516 CROSSING AVENUE, UNIT 1
FIVE POINTS SQUARE
LEWES, DELAWARE 19958
(302) 226-5880
DEVELOPER'S CERTIFICATION
I, WESLEY PAULSON HEREBY CERTIFY THAT REHOBOTH SPOTLIGHT, INC. IS THE
LEGAL OWNER OF THE PROPERTY SHOWN ON THIS PLAN, THAT THE PLAN WAS
MADE AT ITS DIRECTION, THAT IT ACKNOWLEDGES THE SAME TO BE ITS ACT,
AND DESIRES THE PLAN TO BE RECORDED IN ACCORDANCE WITH ALL
APPLICABLE LAWS AND REGULATIONS.
________________________________________________________________________
WESLEY PAULSON, EXECUTIVE DIRECTOR DATE:
CLEAR SPACE THEATRE COMPANY
20 BALTIMORE AVENUE
REHOBOTH BEACH, DE 19971
PHONE: 240-593-4090
8NUMBER OF PARKING STALLS IN ROW
HANDICAP MARKER
SITE LIGHT
REBAR FOUND
RIGHT-OF-WAY LINE
PROPERTY LINE
BUILDING SETBACK LINE
TREELINE
FIRE DEPARTMENT CONNECTION
PROPOSEDEXISTING
UNDERGROUND ELECTRIC
SPOT ELEVATIONS
CONTOUR
STORM SEWER
WATER LINE
SANITARY SEWER
8
HYDRANT
SS
MH
W
S
C.B.
X (18.50)
15''RCP 15''RCP
IRON PIPE FOUND
SANITARY CLEANOUT
CO
SIGN
EASEMENT LINE
CENTERLINE
CONCRETE MONUMENT FOUND
SOIL BORING
WETLAND DELINEATION LINE
EROSION & SEDIMENT CONTROL LEGEND
GAS LINE GAS GAS
GRAVEL DRIVEWAY
CLAM SHELL DRIVEWAY
CONCRETE
HANDICAP PARKING SIGN
PAVERS
UNDERGROUND TELEPHONE
UNDERGROUND TELEPHONE
VINYL PRIVACY FENCE
X X XWOOD PRIVACY FENCE
TRANSFORMER
PARKING METER
WATER METER
A
BUILDING DESIGNATION
N
A
D
8
3
(
2
0
1
1
)
E
p
o
c
h
2
0
1
0
.
0
0
DRAWN BY: DATE: PROJECT:
5215 WEST WOODMILL DRIVE
WILMINGTON, DE 19808
PH: 302-992-7900
FAX: 302-992-7911
35516 CROSSING AVENUE, UNIT 1
FIVE POINTS SQUARE
LEWES, DE 19958
PH: 302-226-5880
7 JANUARY 2020
11720 B
eltsville D
rive
Suite 600
Calverton, M
D 20705
Tel: 301.595.1000
ww
w.grim
mandparker.com
DATE DESCRIPTION
24718LRAG
1. ALL CONSTRUCTION AND MATERIALS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CITY OF REHOBOTH BEACH STANDARD SPECIFICATIONS, THE
STATE OF DELAWARE STATE HIGHWAY DEPARTMENT STANDARD SPECIFICATIONS, DATED AUGUST 2016 AND THE DELAWARE EROSION AND SEDIMENT
CONTROL HANDBOOK, DATED FEBRUARY 2019, AND ALL AMENDMENTS THERETO.
2. EXISTING UTILITIES, UNLESS OTHERWISE NOTED ON THE PLANS, ARE SHOWN IN ACCORDANCE WITH THE BEST AVAILABLE INFORMATION. IT SHALL BE THE
CONTRACTORS RESPONSIBILITY TO CONTACT "MISS UTILITY" 1-800-282-8555 (3) THREE DAYS PRIOR TO CONSTRUCTION IN ORDER TO VERIFY AND ALLOW FOR
THEIR LOCATION AND DEPTH IN THE FIELD.
3. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PROTECT ALL EXISTING UTILITIES AND MAINTAIN UNINTERRUPTED SERVICE. ANY AND ALL
DAMAGES DONE TO EXISTING UTILITIES DUE TO HIS/HER NEGLIGENCE SHALL BE IMMEDIATELY AND COMPETENTLY REPAIRED AT HIS/HER EXPENSE.
4. THE CONTRACTOR SHALL PRESERVE ALL TREES ON THE SITE EXCEPT WHERE NECESSARY TO CONSTRUCT PROPOSED BUILDINGS, UTILITIES, DRIVEWAYS, OR
PARKING AREAS.
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS, LICENSING AND INSURANCE REQUIRED FOR CONSTRUCTION.
6. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO COMPLETELY AND ADEQUATELY CONTROL WATER PRESENT IN THE EXCAVATION. THE CONTRACTOR
SHALL PROVIDE FOR THE DISPOSAL OF WATER REMOVED FROM EXCAVATIONS, IN SUCH A MANNER AS SHALL NOT CAUSE DAMAGE TO PUBLIC OR PRIVATE
PROPERTY OR TO ANY PORTION OF THE WORK COMPLETED OR IN PROGRESS OR CAUSE ANY IMPEDIMENT TO THE USE OF ANY AREA BY THE PUBLIC, IF
APPLICABLE. THE CONTRACTOR SHALL BE REQUIRED TO OBTAIN THE NECESSARY DEWATERING WELL PERMITS FROM THE STATE OF DELAWARE, DNREC
PRIOR TO EXCAVATION.
7. NO DEBRIS WILL BE BURIED ON THIS SITE.
8. PLAN LOCATION AND DIMENSIONS SHALL BE STRICTLY ADHERED TO UNLESS OTHERWISE DIRECTED BY THE ENGINEER.
9. ALL FIRE LANES, FIRE HYDRANTS, AND FIRE DEPARTMENT CONNECTIONS SHALL BE MARKED IN ACCORDANCE WITH THE STATE FIRE PREVENTION
REGULATIONS.
10. THIS SITE IS LOCATED ENTIRELY IN ZONE "X", AREAS DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOOD (100-YEAR FLOOD) AS DESIGNATED ON
THE FLOOD INSURANCE RATE MAPS NUMBER 10005C0340K LAST REVISED 16th MARCH 2015.
11. NO SITE PREPARATION, SITE DISTURBANCE, EXCAVATION OR OTHER CONSTRUCTION ACTIVITY SHALL TAKE PLACE UNTIL ALL PERMITS HAVE BEEN ACQUIRED
BY THE DEVELOPER AND THE SITE PLAN HAS BEEN APPROVED AND RECORDED, IF APPLICABLE.
12. THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE
OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS THERETO APPURTENANT.
13. COPYRIGHT © 2019. MERESTONE CONSULTANTS, INC. ALL RIGHTS RESERVED. NO PART OF THIS DRAWING MAY BE REPRODUCED BY PHOTOCOPYING,
RECORDING OR BY ANY OTHER MEANS, OR STORED, PROCESSED, OR TRANSMITTED IN OR BY ANY COMPUTER OR OTHER SYSTEMS WITHOUT THE PRIOR
WRITTEN PERMISSION OF MERESTONE CONSULTANTS, INC. COPIES OF THIS PLAN WITHOUT COLORED INK SIGNATURE AND A RAISED IMPRESSION SEAL ARE
NOT VALID.
14. THE STATE OF DELAWARE CRITICAL AREA MAPS WERE REVIEWED FOR THIS SITE AND NO STATE OR FEDERALLY REGULATED WETLAND AREAS WERE FOUND
TO EXIST.
WATER DISTRIBUTION SYSTEM GENERAL NOTES :
1. ALL WATER UTILITY COMPONENTS MUST MEET THE REQUIREMENTS OF THE CITY OF REHOBOTH BEACH. PLEASE CONTACT THE PUBLIC WORKS OFFICE AT
302-227-6181 FOR MORE INFORMATION.
2. HYDRANT CONNECTIONS BY THE CONTRACTOR ARE PROHIBITED. THIS METHOD MAY NOT BE UTILIZED DURING ANY PHASE OF THE PROJECT.
3. ANY EXISTING WATER LINES NOT TO BE UTILIZED BY THE PROPOSED FACILITY MUST BE PROPERLY ABANDONED AT THE MAINS IN ACCORDANCE WITH THE CITY
OF REHOBOTH BEACH DEPARTMENT OF PUBLIC WORKS SPECIFICATIONS AND REQUIREMENTS.
4. THE SITE CONTRACTOR SHALL CONTACT THE CITY OF REHOBOTH BEACH PUBLIC WORKS CONSTRUCTION MANAGER AT (302) 227-6181 PRIOR TO THE START OF
CONSTRUCTION. A REPRESENTATIVE FROM THE CITY OF REHOBOTH BEACH DEPARTMENT OF PUBLIC WORKS MUST OBSERVE AND APPROVE ALL CITY OWNED
WATER AND SANITARY SEWER INTERCONNECTIONS AND TESTING. ALL WATER TAPS MUST BE PERFORMED BY A CITY OF REHOBOTH BEACH APPROVED
CONTRACTOR. THE PROPOSED LOCATION FOR THE WATER CONNECTION MAY NEED TO BE ADJUSTED IN THE FIELD DUE TO CONDITIONS OF THE EXISTING MAIN.
POSSIBLE CONDITIONS THAT WOULD REQUIRE TAPPING RELOCATION INCLUDE PROXIMITY TO PIPE JOINTS, OTHER TAPS, CONCRETE ENCASEMENTS, CONFLICT
WITH OTHER UTILITIES, AND THE LIKE. TEST HOLES MUST BE PERFORMED BY THE CONTRACTOR TO DETERMINE THE BEST TAPPING LOCATION. THE CITY OF
REHOBOTH BEACH WILL NOT BE HELD RESPONSIBLE FOR FIELD CONDITIONS REQUIRING ADJUSTMENT OF THE TAPPING LOCATION OR FOR ANY WORK
REQUIRED BY THE CONTRACTOR TO MAKE AN APPROPRIATE AND LAWFUL CONNECTION.
5. ALL WATER INFRASTRUCTURE THAT IS LOCATED ON THE PROPERTY WILL BE MAINTAINED BY THE DEVELOPER, NOT THE CITY OF REHOBOTH BEACH.
6. ALL EXISTING UTILITIES SHALL BE ADJUSTED TO FINAL GRADE IN ACCORDANCE WITH CURRENT CITY OF REHOBOTH BEACH REQUIREMENTS AND PRACTICES.
STATE FIRE MARSHAL NOTES:
1. MAX. BUILDING HEIGHT: THREE STORY (H < 42').
2. N.F.P.A. BUILDING TYPE: TYPE II-000 (NON-COMBUSTIBLE).
3. FIRE SUPPRESSION: AUTOMATIC SPRINKLERS ARE PROPOSED.
4. THE STATE FIRE MARSHAL MAY ACCEPT ALTERNATIVES TO SPECIFIC SYSTEMS, CONDITIONS, ARRANGEMENTS, MATERIALS, OR EQUIPMENT REQUIRED BY
THESE REGULATIONS. SUCH ALTERNATIVES SHALL AFFORD AN EQUIVALENT LEVEL OF FIRE SAFETY, IN THE OPINION OF THE STATE FIRE MARSHAL. AN
ALTERNATIVE PROVIDED FOR BY THIS SECTION DOES NOT CONSTITUTE A VARIANCE, WAIVER, OR SPECIAL EXCEPTION TO THESE REGULATIONS. THE STATE
FIRE MARSHAL HAS APPROVED AN "ALTERNATIVE" REQUEST TO PROVIDE ADDITIONAL FIRE PROTECTION WITHIN THE BUILDINGS TO PROVIDE AN EQUIVALENT
LEVEL OF FIRE SAFETY.
5. THE CLOSEST EDGE OF FIRE LANES SHALL NOT BE LOCATED FURTHER THAN 50FT FROM THE EXTERIOR WALL IF ONE OR TWO STORIES IN HEIGHT; 40FT IF
THREE OR FOUR STORIES IN HEIGHT.
6. BUILDING ACCESS SHALL BE NO FURTHER THAN 50 FEET FROM A PRIMARY ENTRANCE. WHERE BUILDINGS ARE PROVIDED WITH AN AUTOMATIC SPRINKLER
SYSTEM INSTALLED IN ACCORDANCE WITH NFPA 13, ACCESS SHALL BE NO FURTHER THAN 100 FEET FROM THE PRIMARY ENTRANCE.
7. FIRE LANES SHALL HAVE AN UNOBSTRUCTED VERTICAL CLEARANCE OF NOT LESS THAN 13FT 6IN.
8. ALL FIRE LANES SHALL BE MARKED IN ACCORDANCE WITH THE ADOPTED DELAWARE STATE FIRE PREVENTION REGULATIONS. ALL FIRE LANE MARKINGS SHALL
BE IN THE COLOR OF “YELLOW”.
9. PERIMETER ACCESS MINIMUM WIDTH SHALL BE 15FT MEASURED FROM THE FACE OF THE BUILDING AT GRADE WITH A MAXIMUM SLOPE OF 10%. PLANTINGS AND
UTILITY SERVICES SHALL BE PERMITTED WITHIN THE PERIMETER ACCESS AND SHALL NOT INTERFERE WITH EMERGENCY SERVICES FIRE GROUND
OPERATIONS.
10. ADDRESS NUMBERS OF AT LEAST 12 INCHES IN HEIGHT MUST BE PLACED ON THE STREET SIDE OF THE BUILDING VISIBLE FROM THE STREET. LABEL ALL SUITES
IF APPLICABLE.
11. ANY NATURAL OR LP GAS BOTTLES, METERS, VALUES, REGULATORS, ETC., MUST HAVE IMPACT PROTECTION PER CITY OF REHOBOTH BEACH CODE OF
ORDINANCES.
12. FULL BUILDING AND FIRE PLAN REVIEW IS REQUIRED.
13. BUILDING CANNOT BE OCCUPIED OR CONSTRUCTION OR RENOVATIONS STARTED UNTIL COMPLETION OF BUILDING AND FIRE PLAN REVIEW.
14. ALL REQUIRED MEANS OF EGRESS SHALL HAVE AN EXIT DISCHARGE CONSISTING OF A NON SLIP SURFACE, AND LEADING TO AND TERMINATING AT A PUBLIC
WAY.
15. FIRE ALARM SYSTEM MAY BE REQUIRED PER OCCUPANCY CODE REQUIREMENTS.
16. KNOX BOX REQUIRED AT ALL TENANT SPACES. A KNOX BOX CONTAINING KEYS FOR FIRE DEPARTMENT ACCESS SHALL BE PROVIDED IN THE BUILDING. THE
KNOX BOX SHALL BE LISTED OR APPROVED BY THE STATE FIRE MARSHAL FOR THE INTENDED USE AND INSTALLED IN SUCH A MANNER THAT THE FIRE
DEPARTMENT WILL HAVE ACCESS TO THE BOX. CONTACT THE LOCAL FIRE CHIEF FOR ORDERING INFORMATION AND LOCATION OF BOX ON BUILDING.
17. STANDPIPES MAY BE REQUIRED.
18. SMOKE CONTROL MAY BE REQUIRED.
19. ELEVATOR CARS TO MEET THE INTERIOR DIMENSIONS SET FORTH IN THE DELAWARE STATE FIRE PREVENTION CODE.
20. PROJECT TO BE COMPLETED PER APPROVED SITE PLAN.
21. MULTIPLE ACCESS ROADS SHALL BE PROVIDED WHEN A FIRE DEPARTMENT ACCESS ROAD (FIRE LANE) IS DETERMINED BY THE FIRE MARSHAL TO BE IMPAIRED
BY VEHICLE CONGESTION, CONDITION OF TERRAIN, CLIMATIC CONDITIONS, OR OTHER FACTORS THAT COULD LIMIT ACCESS SUCH AS PLACEMENT OF FIRE
HOSE FROM FIRE EQUIPMENT.
SANITARY SEWER GENERAL NOTES :
1. ALL WASTEWATER UTILITY COMPONENTS MUST MEET THE REQUIREMENTS OF THE CITY OF REHOBOTH BEACH, PLEASE CONTACT THE PUBLIC WORKS OFFICE
AT 302-227-6181 FOR MORE INFORMATION
2. ANY EXISTING SANITARY SEWER LINES NOT TO BE UTILIZED BY THE PROPOSED FACILITY MUST BE PROPERLY ABANDONED AT THE MAINS IN ACCORDANCE
WITH THE CITY OF REHOBOTH BEACH DEPARTMENT OF PUBLIC WORKS SPECIFICATIONS AND REQUIREMENTS.
3. CLEANOUTS MUST BE INSTALLED ON SANITARY SEWER LATERALS WITHIN FIVE FEET (5’) OF THE BUILDING, ONE FOOT (1’) OUTSIDE OF THE RIGHT-OF-WAY AND
AT ALL BENDS. ANY CLEANOUT LOCATED WITHIN A TRAFFIC BEARING LOCATION SHALL BE INSTALLED WITH A HEAVY DUTY CAST IRON FRAME AND COVER TO
PREVENT DAMAGE TO THE CLEANOUT AND LATERAL.
4. THE MINIMUM SIZE OF ALL SANITARY SEWER LATERALS SHALL BE FOUR-INCH (4”).
5. SANITARY SEWER LATERALS SHALL BE CONNECTED DIRECTLY TO THE MAIN, NOT MANHOLES, UNLESS IMPRACTICABLE, AS DETERMINED BY THE DEPARTMENT
OF PUBLIC WORKS.
SANITARY SEWER LOCATION WITH RELATION TO THE WATER MAINS
1. SANITARY SEWER SHALL BE LAID AT LEAST 10 FEET HORIZONTALLY FROM ANY EXISTING OR PROPOSED WATER MAINS. THE DISTANCE SHALL BE MEASURED
OUTSIDE EDGE TO OUTSIDE EDGE.
2. SANITARY SEWER CROSSING WATER MAINS SHALL BE LAID TO PROVIDE A MINIMUM VERTICAL DISTANCE OF 18 INCHES BETWEEN THE OUTSIDE OF THE WATER
MAIN AND THE OUTSIDE OF THE SANITARY SEWER. THIS SHALL BE THE CASE WHERE THE WATER MAIN IS EITHER ABOVE OR BELOW THE SANITARY SEWER.
THE CROSSING SHALL BE ARRANGED SO THAT THE SANITARY SEWER JOINTS WILL BE EQUIDISTANT AND AS FAR AS POSSIBLE FROM THE WATER MAIN JOINTS.
IF SPACING IS LESS THAN 18" VERTICAL DISTANCE, THE TOWN OF MILLSBORO REQUIRES CASING AROUND THE SANITARY SEWER PIPE 10 FEET IN EITHER
DIRECTION FOR A TOTAL OF 20 FEET. THE END TREATMENTS FOR THE SLEEVE SHALL BE FERNCO COUPLERS/SEALS, MANUFACTURER PART NUMBER #1056-86
OR APPROVED EQUAL BY YHE TOWN OF MILLSBORO.
3. WHEN IT IS IMPOSSIBLE TO OBTAIN PROPER HORIZONTAL AND VERTICAL SEPARATION AS STIPULATED ABOVE, CONCRETE ENCASEMENT SHALL BE REQUIRED
TO BE INSTALLED A MINIMUM OF 5 FEET EACH SIDE OF THE CROSSING POINT ON THE LOWEST UTILITY. (SEE CONCRETE ENCASEMENT DETAIL.)
4. NO WATER PIPE SHALL PASS THROUGH OR COME IN CONTACT WITH ANY PART OF A SEWER MANHOLE.
R:\P
ro
je
cts\24718L C
le
ar S
pace T
heater\D
WG
\2
47
18
L-S
urvey.dw
g, 4/2
0/20
20
12
:44
:1
2 P
M, D
WG
T
o P
DF
.pc3
S
CO
NS
OLI
DA
TE
D P
ER
MIT
SE
T 5
/12/
2020
:S
ITE
PLA
N, A
RC
HIT
EC
TU
RA
L P
LAN
S,
SE
CT
ION
S A
ND
ELE
VA
TIO
NS
.*N
OT
FO
R C
ON
ST
RU
CT
ION
*
UP
UP
A16A201S
G11A201S
A14A202S
G9A202S
10' -
0"
85' -
0"
5' -
0"
50' - 0"
24' - 10 1/8"
46' -
1 7
/8"
100'
- 0"
46' - 0" 4' - 0"
14' -
3 1
/2"
24' -
6 5
/8"
8' - 11 3/8" 18' - 5"
BLACK BOXTHEATRE
109
FIRE PUMP
110
TOILET
106
TOILET
107
ELEVATOR
ELEV 01
WATER RM
102
BOX OFFICE
103
44' -
9"
3' - 11"
5' -
0"15
' - 1
0 5/
8"44
' - 1
3/8
"20
' - 0
"
6' - 0 3/4" 9' - 3 1/8"
2" 23' - 10" 18' - 1"
STAIR 2
ST2
7' - 4 1/4"
8' -
8 1/
8"5'
- 6"
8' -
4"9'
- 0
3/8"
13' - 1"
1' -
9 7/
8"4'
- 4
3/8"
TOILET
111
LOBBY
105
CLST
104
A501S
A3
A501S
F7
A504S
A5
A505S
A5
A14
A401S
1
A402S
5' - 1"
K1
K1
K1
E4
K1
X1
K1
A3
A3
K1
X1
X1
J5
J5
X1
A3
E4
A3
A3
K1
SUMP PIT
UTILITY
108S102
108
107
106
103
X01
S101
X03
102
111
109
104
CLST
112112
3' -
4 1/
2"3'
- 0"
14' - 3 11/16"
KITCHEN EQUIPMENT, NOT IN CONTRACT
2
A402S
1S
1S
1S
1S
1S
1S
109B
SL2
2S
2S
3' - 0"
STAIR 1
ST1
SF16
SF19
SF13
X02
F7
A306S
15' -
10
5/8"
4' -
11 3
/8"
6' -
5"12
' - 9
5/8
"1'
- 9
7/8"
8' -
0"2'
- 0
1/2"
9' -
2"8'
- 4
1/8"
9' -
3 5/
8"
FOODESTABLISHMENT
101
EXTERIOR TICKET COUNTER
PROPERTY LINE
PROPERTY LINE
PR
OP
ER
TY L
INE
PR
OP
ER
TY L
INE
3' - 10"
SF01
SF02
X1
X1
1. REFER TO SHEET A-301 FOR WALL TYPES AS REFERENCED ON PLANS WITH THE DIAMOND SYMBOL. 2. TYPICAL GYPSUM BOARDS/STUD WALL PARTITION TO BE TYPE J2 UNLESS INDICATED OTHERWISE BY WALL TYPE
SYMBOLS, WALL SECTIONS OR OTHER DETAILS.3. TYPICAL GYPSUM BOARD CHASE WALLS TO BE TYPE X1 UNLESS INDICATED OTHERWISE BY WALL TYPE SYMBOLS,
WALL SECTIONS OR OTHER DETAILS.4. UNLESS NOTED OTHERWISE, WALLS MUST EXTEND TO THE ROOF OR FLOOR DECK ABOVE AND BE SEALED IN
ACCORDANCE WITH THE WALL TERMINATION DETAILS. REFER TO THE CODE STUDY PLAN FOR IDENTIFICATION OF ALL SMOKE AND FIRE WALL CONDITIONS. PERIMETER CORRIDOR AND LOBBY WALLS MUST BE BUILT TO RESIST THE PASSAGE OF SMOKE.
5. DIMENSIONS ON PLANS ARE FROM FACE OF MASONRY TO FACE OF MASONRY, FACE OF MASONRY TO FACE OF GYPSUM BOARD OR FACE OF GYPSUM BOARD TO FACE OF GYPSUM BOARD.
6. COLUMN GRID LINES ARE FOR REFERENCE ONLY, REFER TO STRUCTURAL DRAWINGS FOR COLUMN LOCATIONS.7. FEC - INDICATES A FIRE EXTINGUISHER WITH A RECESSED CABINET. FE - INDICATES A FIRE EXTINGUISHER WITH A
WALL MOUNTING BRACKET.8. UNLESS SPECIFICALLY INDICATED OTHERWISE, THE SAME WALL TYPE NEXT TO A DOOR OR OPENING TO
CONTINUE OVER THE DOOR OR OPENING.9. PLAN LOCATION OF DOORS AND FRAMES RELATIVE TO THE PLANE OF THE WALL IS DIAGRAMMATIC ONLY. REFER
TO THE REFERENCED JAMB AND HEAD CONDITION DETAILS TO DETERMINE ACTUAL PLACEMENT OF DOOR AND FRAME.
GENERAL PLAN NOTES
GENERAL NOTE APPLICABLE TO ALL DRAWINGS - ITEMS AND CONDITIONS DETAILED, NOTED OR OTHERWISE IDENTIFIED ON ONE OF THE SECTIONS OR DETAILS ARE APPLICABLE AND BINDING TO ALL OTHER SECTIONS AND DETAILS FOR IDENTICAL OR SIMILAR CONDITIONS.
1. ALL CONSTRUCTION AND WORK REPRESENTED IN THE COMPLETE SET OF DOCUMENTS IS ASSUMED TO BE NEW AND FURNISHED AND INSTALLED BY THE CONTRACTOR UNLESS OTHERWISE NOTED.
2. IF A CONFLICT EXISTS WITHIN OR BETWEEN DRAWINGS AND SPECIFICATIONS, THE MORE STRINGENT AND MORE COSTLY REQUIREMENT TO APPLY. ITEMS SHOWN ON THE DRAWINGS, BUT NOT SPECIFIED, TO APPLY AND BE PROVIDED BY THE CONTRACTOR. IF AN ITEM IS SHOWN ON THE DRAWINGS, BUT IS NOT INCLUDED IN THE SPECIFICATIONS, PROVIDE ITEM OF A QUALITY LEVEL CONSISTENT WITH THE GENERAL QUALITY LEVEL OF THE CONTRACT REQUIREMENTS. REPORT CONFLICTS BETWEEN THE DRAWINGS AND SPECIFICATIONS TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY.
3. IF A CONFLICT EXISTS BETWEEN DRAWINGS OF DIFFERENT SCALES, CONSULT THE ARCHITECT FOR CLARIFICATION. 4. IN THE ABSENCE OF A WRITTEN DIMENSION, OR IN CASE OF DOUBT AS TO THE PROPER MEASUREMENT, CONSULT THE
ARCHITECT FOR CLARIFICATION. 5. IF AN AREA OR SPACE IS SHOWN, BUT IS NOT CLEARLY DEFINED OR INDICATED BY NOTES, PROVIDE THE SAME
MATERIALS AND FINISHES AS SCHEDULED OR DETAILED FOR AREAS OF SIMILAR USE ELSEWHERE IN THE BUILDING, 6. SECTIONS INDICATED ARE INTENDED TO SHOW THE SPECIFIC CONSTRUCTION WHERE REFERENCED AS WELL AS
ESTABLISH THE GENERAL CONSTRUCTION DETAILS FOR SECTIONS THROUGHOUT THE PROJECT WHICH DO NOT HAVE SPECIFIC SECTIONS DRAWN. THE MOST SIMILAR SECTIONS TO BE ADAPTED TO ANY SECTIONS NOT DETAILED. ANY SPECIFIC QUESTIONS CONCERNING CONSTRUCTION NOT ADEQUATELY COVERED BY THE ABOVE SHOULD BE DIRECTED TO THE ARCHITECT DURING THE BIDDING.
7. TYPICAL DETAILS THROUGHOUT THE DRAWING SET TO APPLY FOR ALL APPLICABLE CONDITIONS EVEN IF NOT SPECIFICALLY SHOWN OR REFERENCED.
8. SEE STRUCTURAL DRAWINGS FOR ACTUAL STRUCTURAL STEEL AND BEARING ELEVATIONS. 9. REFER TO ARCHITECTURAL SITE PLAN FOR THE LAYOUT OF CONCRETE WALKS, MOW STRIPS, PAVING PATTERNS, ETC.
IN THE BUILDING VICINITY. REFER TO CIVIL DRAWINGS FOR THE CONTINUATION OF THIS WORK. 10. AT ALL OUTSIDE CORNERS OF INTERIOR CMU WALLS, COLUMN ENCLOSURES, PIPE CHASES OR OTHER WALL
PROJECTIONS, PROVIDE MASONRY UNITS WITH BULLNOSED (ROUNDED) EDGES WITH 1" RADIUS, UNLESS OTHERWISE NOTED OR WHERE SCHEDULED TO RECEIVE CERAMIC TILE. WHERE MASONRY CORNERS ALIGN WITH BULKHEADS, TRANSITION FROM BULLNOSE CORNER UNITS TO SQUARE CORNER UNITS.
11. UNLESS SPECIFICALLY NOTED OTHERWISE, ENCLOSE ALL VERTICAL MECHANICAL PIPES, RAIN LEADERS, ETC. WITH 4" CMU OR GYPSUM BOARD TO MATCH SURROUNDING FINISHES.
12. REFER TO PLANS AND ELEVATIONS FOR LOCATIONS OF CONTROL JOINTS (C.J.) AND EXPANSION JOINTS (E.J.) IN EXTERIOR MASONRY WALLS. IF A CONFLICT EXISTS BETWEEN JOINT LOCATIONS SHOWN ON THE ELEVATIONS AND PLANS, CONSULT THE ARCHITECT FOR CLARIFICATION PRIOR TO CONSTRUCTION. REFER TO FLOOR PLANS FOR LOCATIONS OF CONTROL JOINTS (C.J.) IN INTERIOR MASONRY WALLS.
13. ALL EXTERIOR CAVITY WALLS TO HAVE CONTINUOUS FLEXIBLE FLASHING AT THE BOTTOM OF THE CAVITY WITH WEEP VENTS TO THE OUTSIDE. ALL FLASHING BUILT INTO WALLS TO BE LAPPED AND SEALED. REFER TO FLASHING DETAILS INDICATED.
14. REFER TO BUILDING ELEVATIONS AND ELEVATION DETAILS FOR MASONRY PATTERNS. 15. INCLUDE PROJECTIONS, BEAM ENCLOSURES, RECESSES, BULKHEADS, PILASTERS AND SIMILAR ENCLOSURES AS PART
OF WALL AND CEILING FINISHES AS SCHEDULED. 16. ALL APPURTENANCES BUILT INTO OR THROUGH WALLS, INCLUDING DOORS, DUCTS, WINDOWS, LOUVERS, GRILLES,
MECHANICAL WORK, ETC. TO FIT TIGHT AND BE THOROUGHLY SEALED AROUND PERIMETERS. WORK AT EXTERIOR WALLS TO BE FLASHED OR OTHERWISE WATERPROOF SEALED.
17. FIELD CHECK ROUGH AND/OR FINISHED DIMENSIONS FOR ACCURATE FITTING OF CABINETS, COUNTERS, LOCKERS, DOORS, WINDOWS, FIXTURES, SHELVING, GATES AND OTHER INSTALLATIONS PRIOR TO SHOP OR FACTORY FABRICATION. PROVIDE FILLER STRIPS, SCRIBE STRIPS, BASES, CLOSURE FINISHES AND TRIM FOR A COMPLETE INSTALLATION.
18. PROVIDE APPROPRIATE TRANSITION STRIPS AT CHANGES IN FLOOR ELEVATIONS. 19. EACH CONTRACTOR MUST REFER TO ALL DRAWINGS AND BE RESPONSIBLE FOR WORK PERTAINING TO THEIR
PARTICULAR TRADE. ALL CONTRACTORS MUST COORDINATE THE WORK OF ALL TRADES AND FIELD CHECK AGAINST ANY CONFLICTS BETWEEN DRAWINGS. REPORT CONFLICTS TO THE ARCHITECT FOR CLARIFICATION.
20. ACCESS PANELS, LOUVER OPENINGS, VENTILATORS, GRILLES, VALVE CABINETS, FIRE DAMPERS OR OTHER APPURTENANCES AFFECTING WALLS, CEILINGS OR FLOORS ARE SHOWN THROUGHOUT THE DRAWINGS. PROVIDE NECESSARY LINTELS, SUPPORT AND ANCHORAGE. SEE STRUCTURAL NOTES FOR LINTEL REQUIREMENTS.
21. REFER TO MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR LOCATIONS OF CONCRETE PADS TO BE PROVIDED BELOW OR AROUND EQUIPMENT.
22. INSTALL ELECTRIC SWITCHES, OUTLETS, THERMOSTATS, CONTROLS, CLOCKS, SPEAKERS, FLAGPOLE HOLDERS AND OTHER WALL-MOUNTED ACCESSORIES IN LOCATIONS WHICH ARE UNOBSTRUCTED BY CABINETS, COUNTERS, RACKS, DISPLAY BOARDS, FIXTURES, SHELVING OR OTHER FURNISHINGS OR EQUIPMENT DESIGNATED FOR SPACES SHOWN ON DRAWINGS. THESE DEVICES MAY BE SHOWN ON THE ARCHITECTURAL DRAWINGS TO ALERT OTHER SUB-CONTRACTORS OF THEIR PRESENCE. COORDINATE INSTALLATION WITH THE ELECTRICAL DRAWINGS. ADVISE THE ARCHITECT OF CONFLICTS IN LOCATION OR TYPES OF DEVICES SHOWN PRIOR TO INSTALLATION. DO NOT INSTALL WALL-MOUNTED ITEMS ON, THROUGH OR INTO ANY EQUIPMENT UNLESS INDICATED.
23. MOUNT ELECTRIC SWITCHES, THERMOSTATS AND OTHER ELECTRONIC CONTROLS LOCATED IN THE SAME VICINITY AT THE SAME HEIGHT ABOVE FINISHED FLOOR IN A UNIFORM, ORDERLY FASHION UNLESS NOTED OTHERWISE.
24. FOR THE PURPOSES OF BIDDING (UNLESS OTHERWISE NOTED), ALL SYMBOLS (LABELED / TAGGED OR UNLABELED/UNTAGGED) WHICH ARE LOCATED ON THE FURNISHING/EQUIPMENT PLANS TO BE CONSIDERED AS IN CONTRACT WORK TO BE PROVIDED BY THE CONTRACTOR. ALL SYMBOLS LOCATED ON THE PLANS DENOTE EITHER FURNITURE, EQUIPMENT, CASEWORK OR MILLWORK. WHERE A SYMBOL IS LOCATED ON THE PLANS BUT IS NOT LABELED OR TAGGED TO A SCHEDULE, THE CONTRACTOR MUST SEEK CLARIFICATION FROM THE OWNER OR ARCHITECT BEFORE PROCEEDING. FOR PURPOSES OF BIDDING ONLY, IF CLARIFICATION CANNOT BE OBTAINED FROM THE OWNER OR ARCHITECT THROUGH ADDENDUM PRIOR TO THE BID DATE, THE CONTRACTOR MUST NEVERTHELESS INCLUDE THE ITEM IN QUESTION IN THEIR BID, CONSIDERING IT THE SAME AS THE TAGGED SYMBOL MOST NEARLY RESEMBLING THE UNTAGGED SYMBOL BASED ON ITS SHAPE, SIZE, LINEWEIGHT(S), LOCATION, AND SCHEDULED USAGE IN SPACES OF SIMILAR FUNCTION. THE CONTRACTOR MUST OBTAIN CLARIFICATION FROM THE ARCHITECT PRIOR TO PROCEEDING WITH SHOP DRAWINGS.
GENERAL NOTES
123456789101112131415161718
11720 B
eltsvill
e D
rive
Suite 6
00
Calv
ert
on,
MD
20705
Tel: 3
01.5
95.1
000
123456789101112131415161718
A
B
C
D
E
F
G
H
J
K
L
M
A
B
C
D
E
F
G
H
J
K
L
M
© GRIMM AND PARKER, P.C. 2014
© GRIMM AND PARKER, P.C. 2014
ww
w.g
rim
mandpark
er.
com
PROFESSIONAL CERTIFICATION
I CERTIFY THAT THESE DOCUMENTS
WERE PREPARED OR APPROVED BY
ME, AND I AM A DULY LICENSED
ARCHITECT UNDER THE STATE OF
DELAWARE,
LICENSE NUMBER# 8570
EXPIRATION: 1/31/2022
A101S
FIR
ST
FLO
OR
PLA
N 1
/4 S
CA
LE
REHO
BOTH
SPO
TLIG
HT IN
C.41
7 REH
OBOT
H AV
E RE
HOBO
TH B
EACH
, DE
1997
1
4/17/2020PERMIT SUBMISSION
GP #21828.00
1/4" = 1'-0"A10FIRST FLOOR PLAN
N
0 4' 8'2'
DATE DESCRIPTION
CO
NS
OLI
DA
TE
D P
ER
MIT
SE
T 5
/12/
2020
:S
ITE
PLA
N, A
RC
HIT
EC
TU
RA
L P
LAN
S,
SE
CT
ION
S A
ND
ELE
VA
TIO
NS
.*N
OT
FO
R C
ON
ST
RU
CT
ION
*
H
T
A16A201S
G11A201S
A14A202S
G9A202S
15' -
5 1
/2"
5' -
5"2'
- 7
1/4"
15' -
4 3
/8"
PRACTICE 5
206
PRACTICE 3
203
PRACTICE 4
204
KITCHENETTE
209
ELEV. RM
207
TOILET
210
IT/DIMMING
211
UTILITY
212
28' -
5"
31' -
7"
20' -
0"
10' -
0"
80' -
0"
5' -
0"
23' - 10" 18' - 1"
41' - 11"
2"
24' - 8 1/4" 21' - 1 3/4"
85' -
0"
4' - 0"
10' - 8 3/4" 10' - 10 3/4" 10' - 1 1/8"
3' - 11"
ELEVATOR
ELEV 01
PRACTICE 2
202
JC
205
LOBBY
208
A501S
F11
A14
A401S
1
A402S
K1
E4
J5
K1
K1
K1
K1
K1
E4
E4
A3
K1
K1
K1
K1
A3
A3
X1
A3
OPEN TO BELOW
STAIR 2
ST2
A505S
E5
A504S
D5
201
202 203 204
207206
205
S201
209
210
211
212
S202
6' - 0 3/4" 7' - 10 1/4"
2
A402S
1S
1S
1S
1S
2S
2S1S
1S
1S
PRACTICE 1
201
STAIR 1
ST1
3"
4' - 10 3/4" 14' - 0 1/2" 4' - 10 3/4" 3' - 1 1/2" 14' - 8 1/2" 3"
SF17
ESF20
SF14A501S
D11
7' - 7 1/4" 7' - 3 1/8"
8' -
8 1/
2"7'
- 6"
1' -
7 3/
8"7'
- 11
1/8
"8'
- 7
7/8"
8' -
8"
15' -
5 1
/2"
5' -
5"2'
- 7
1/4"
13' -
11
1/2"
2' - 9 5/8"
5' -
5"
3' -
8 5/
8"9'
- 6
3/4"
UP
DN
DN
UP
4' - 5 1/4" 7 3/4"
GENERAL NOTE APPLICABLE TO ALL DRAWINGS - ITEMS AND CONDITIONS DETAILED, NOTED OR OTHERWISE IDENTIFIED ON ONE OF THE SECTIONS OR DETAILS ARE APPLICABLE AND BINDING TO ALL OTHER SECTIONS AND DETAILS FOR IDENTICAL OR SIMILAR CONDITIONS.
1. ALL CONSTRUCTION AND WORK REPRESENTED IN THE COMPLETE SET OF DOCUMENTS IS ASSUMED TO BE NEW AND FURNISHED AND INSTALLED BY THE CONTRACTOR UNLESS OTHERWISE NOTED.
2. IF A CONFLICT EXISTS WITHIN OR BETWEEN DRAWINGS AND SPECIFICATIONS, THE MORE STRINGENT AND MORE COSTLY REQUIREMENT TO APPLY. ITEMS SHOWN ON THE DRAWINGS, BUT NOT SPECIFIED, TO APPLY AND BE PROVIDED BY THE CONTRACTOR. IF AN ITEM IS SHOWN ON THE DRAWINGS, BUT IS NOT INCLUDED IN THE SPECIFICATIONS, PROVIDE ITEM OF A QUALITY LEVEL CONSISTENT WITH THE GENERAL QUALITY LEVEL OF THE CONTRACT REQUIREMENTS. REPORT CONFLICTS BETWEEN THE DRAWINGS AND SPECIFICATIONS TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY.
3. IF A CONFLICT EXISTS BETWEEN DRAWINGS OF DIFFERENT SCALES, CONSULT THE ARCHITECT FOR CLARIFICATION. 4. IN THE ABSENCE OF A WRITTEN DIMENSION, OR IN CASE OF DOUBT AS TO THE PROPER MEASUREMENT, CONSULT THE
ARCHITECT FOR CLARIFICATION. 5. IF AN AREA OR SPACE IS SHOWN, BUT IS NOT CLEARLY DEFINED OR INDICATED BY NOTES, PROVIDE THE SAME
MATERIALS AND FINISHES AS SCHEDULED OR DETAILED FOR AREAS OF SIMILAR USE ELSEWHERE IN THE BUILDING, 6. SECTIONS INDICATED ARE INTENDED TO SHOW THE SPECIFIC CONSTRUCTION WHERE REFERENCED AS WELL AS
ESTABLISH THE GENERAL CONSTRUCTION DETAILS FOR SECTIONS THROUGHOUT THE PROJECT WHICH DO NOT HAVE SPECIFIC SECTIONS DRAWN. THE MOST SIMILAR SECTIONS TO BE ADAPTED TO ANY SECTIONS NOT DETAILED. ANY SPECIFIC QUESTIONS CONCERNING CONSTRUCTION NOT ADEQUATELY COVERED BY THE ABOVE SHOULD BE DIRECTED TO THE ARCHITECT DURING THE BIDDING.
7. TYPICAL DETAILS THROUGHOUT THE DRAWING SET TO APPLY FOR ALL APPLICABLE CONDITIONS EVEN IF NOT SPECIFICALLY SHOWN OR REFERENCED.
8. SEE STRUCTURAL DRAWINGS FOR ACTUAL STRUCTURAL STEEL AND BEARING ELEVATIONS. 9. REFER TO ARCHITECTURAL SITE PLAN FOR THE LAYOUT OF CONCRETE WALKS, MOW STRIPS, PAVING PATTERNS, ETC.
IN THE BUILDING VICINITY. REFER TO CIVIL DRAWINGS FOR THE CONTINUATION OF THIS WORK. 10. AT ALL OUTSIDE CORNERS OF INTERIOR CMU WALLS, COLUMN ENCLOSURES, PIPE CHASES OR OTHER WALL
PROJECTIONS, PROVIDE MASONRY UNITS WITH BULLNOSED (ROUNDED) EDGES WITH 1" RADIUS, UNLESS OTHERWISE NOTED OR WHERE SCHEDULED TO RECEIVE CERAMIC TILE. WHERE MASONRY CORNERS ALIGN WITH BULKHEADS, TRANSITION FROM BULLNOSE CORNER UNITS TO SQUARE CORNER UNITS.
11. UNLESS SPECIFICALLY NOTED OTHERWISE, ENCLOSE ALL VERTICAL MECHANICAL PIPES, RAIN LEADERS, ETC. WITH 4" CMU OR GYPSUM BOARD TO MATCH SURROUNDING FINISHES.
12. REFER TO PLANS AND ELEVATIONS FOR LOCATIONS OF CONTROL JOINTS (C.J.) AND EXPANSION JOINTS (E.J.) IN EXTERIOR MASONRY WALLS. IF A CONFLICT EXISTS BETWEEN JOINT LOCATIONS SHOWN ON THE ELEVATIONS AND PLANS, CONSULT THE ARCHITECT FOR CLARIFICATION PRIOR TO CONSTRUCTION. REFER TO FLOOR PLANS FOR LOCATIONS OF CONTROL JOINTS (C.J.) IN INTERIOR MASONRY WALLS.
13. ALL EXTERIOR CAVITY WALLS TO HAVE CONTINUOUS FLEXIBLE FLASHING AT THE BOTTOM OF THE CAVITY WITH WEEP VENTS TO THE OUTSIDE. ALL FLASHING BUILT INTO WALLS TO BE LAPPED AND SEALED. REFER TO FLASHING DETAILS INDICATED.
14. REFER TO BUILDING ELEVATIONS AND ELEVATION DETAILS FOR MASONRY PATTERNS. 15. INCLUDE PROJECTIONS, BEAM ENCLOSURES, RECESSES, BULKHEADS, PILASTERS AND SIMILAR ENCLOSURES AS PART
OF WALL AND CEILING FINISHES AS SCHEDULED. 16. ALL APPURTENANCES BUILT INTO OR THROUGH WALLS, INCLUDING DOORS, DUCTS, WINDOWS, LOUVERS, GRILLES,
MECHANICAL WORK, ETC. TO FIT TIGHT AND BE THOROUGHLY SEALED AROUND PERIMETERS. WORK AT EXTERIOR WALLS TO BE FLASHED OR OTHERWISE WATERPROOF SEALED.
17. FIELD CHECK ROUGH AND/OR FINISHED DIMENSIONS FOR ACCURATE FITTING OF CABINETS, COUNTERS, LOCKERS, DOORS, WINDOWS, FIXTURES, SHELVING, GATES AND OTHER INSTALLATIONS PRIOR TO SHOP OR FACTORY FABRICATION. PROVIDE FILLER STRIPS, SCRIBE STRIPS, BASES, CLOSURE FINISHES AND TRIM FOR A COMPLETE INSTALLATION.
18. PROVIDE APPROPRIATE TRANSITION STRIPS AT CHANGES IN FLOOR ELEVATIONS. 19. EACH CONTRACTOR MUST REFER TO ALL DRAWINGS AND BE RESPONSIBLE FOR WORK PERTAINING TO THEIR
PARTICULAR TRADE. ALL CONTRACTORS MUST COORDINATE THE WORK OF ALL TRADES AND FIELD CHECK AGAINST ANY CONFLICTS BETWEEN DRAWINGS. REPORT CONFLICTS TO THE ARCHITECT FOR CLARIFICATION.
20. ACCESS PANELS, LOUVER OPENINGS, VENTILATORS, GRILLES, VALVE CABINETS, FIRE DAMPERS OR OTHER APPURTENANCES AFFECTING WALLS, CEILINGS OR FLOORS ARE SHOWN THROUGHOUT THE DRAWINGS. PROVIDE NECESSARY LINTELS, SUPPORT AND ANCHORAGE. SEE STRUCTURAL NOTES FOR LINTEL REQUIREMENTS.
21. REFER TO MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR LOCATIONS OF CONCRETE PADS TO BE PROVIDED BELOW OR AROUND EQUIPMENT.
22. INSTALL ELECTRIC SWITCHES, OUTLETS, THERMOSTATS, CONTROLS, CLOCKS, SPEAKERS, FLAGPOLE HOLDERS AND OTHER WALL-MOUNTED ACCESSORIES IN LOCATIONS WHICH ARE UNOBSTRUCTED BY CABINETS, COUNTERS, RACKS, DISPLAY BOARDS, FIXTURES, SHELVING OR OTHER FURNISHINGS OR EQUIPMENT DESIGNATED FOR SPACES SHOWN ON DRAWINGS. THESE DEVICES MAY BE SHOWN ON THE ARCHITECTURAL DRAWINGS TO ALERT OTHER SUB-CONTRACTORS OF THEIR PRESENCE. COORDINATE INSTALLATION WITH THE ELECTRICAL DRAWINGS. ADVISE THE ARCHITECT OF CONFLICTS IN LOCATION OR TYPES OF DEVICES SHOWN PRIOR TO INSTALLATION. DO NOT INSTALL WALL-MOUNTED ITEMS ON, THROUGH OR INTO ANY EQUIPMENT UNLESS INDICATED.
23. MOUNT ELECTRIC SWITCHES, THERMOSTATS AND OTHER ELECTRONIC CONTROLS LOCATED IN THE SAME VICINITY AT THE SAME HEIGHT ABOVE FINISHED FLOOR IN A UNIFORM, ORDERLY FASHION UNLESS NOTED OTHERWISE.
24. FOR THE PURPOSES OF BIDDING (UNLESS OTHERWISE NOTED), ALL SYMBOLS (LABELED / TAGGED OR UNLABELED/UNTAGGED) WHICH ARE LOCATED ON THE FURNISHING/EQUIPMENT PLANS TO BE CONSIDERED AS IN CONTRACT WORK TO BE PROVIDED BY THE CONTRACTOR. ALL SYMBOLS LOCATED ON THE PLANS DENOTE EITHER FURNITURE, EQUIPMENT, CASEWORK OR MILLWORK. WHERE A SYMBOL IS LOCATED ON THE PLANS BUT IS NOT LABELED OR TAGGED TO A SCHEDULE, THE CONTRACTOR MUST SEEK CLARIFICATION FROM THE OWNER OR ARCHITECT BEFORE PROCEEDING. FOR PURPOSES OF BIDDING ONLY, IF CLARIFICATION CANNOT BE OBTAINED FROM THE OWNER OR ARCHITECT THROUGH ADDENDUM PRIOR TO THE BID DATE, THE CONTRACTOR MUST NEVERTHELESS INCLUDE THE ITEM IN QUESTION IN THEIR BID, CONSIDERING IT THE SAME AS THE TAGGED SYMBOL MOST NEARLY RESEMBLING THE UNTAGGED SYMBOL BASED ON ITS SHAPE, SIZE, LINEWEIGHT(S), LOCATION, AND SCHEDULED USAGE IN SPACES OF SIMILAR FUNCTION. THE CONTRACTOR MUST OBTAIN CLARIFICATION FROM THE ARCHITECT PRIOR TO PROCEEDING WITH SHOP DRAWINGS.
GENERAL NOTES
1. REFER TO SHEET A-301 FOR WALL TYPES AS REFERENCED ON PLANS WITH THE DIAMOND SYMBOL. 2. TYPICAL GYPSUM BOARDS/STUD WALL PARTITION TO BE TYPE J2 UNLESS INDICATED OTHERWISE BY WALL TYPE
SYMBOLS, WALL SECTIONS OR OTHER DETAILS.3. TYPICAL GYPSUM BOARD CHASE WALLS TO BE TYPE X1 UNLESS INDICATED OTHERWISE BY WALL TYPE SYMBOLS,
WALL SECTIONS OR OTHER DETAILS.4. UNLESS NOTED OTHERWISE, WALLS MUST EXTEND TO THE ROOF OR FLOOR DECK ABOVE AND BE SEALED IN
ACCORDANCE WITH THE WALL TERMINATION DETAILS. REFER TO THE CODE STUDY PLAN FOR IDENTIFICATION OF ALL SMOKE AND FIRE WALL CONDITIONS. PERIMETER CORRIDOR AND LOBBY WALLS MUST BE BUILT TO RESIST THE PASSAGE OF SMOKE.
5. DIMENSIONS ON PLANS ARE FROM FACE OF MASONRY TO FACE OF MASONRY, FACE OF MASONRY TO FACE OF GYPSUM BOARD OR FACE OF GYPSUM BOARD TO FACE OF GYPSUM BOARD.
6. COLUMN GRID LINES ARE FOR REFERENCE ONLY, REFER TO STRUCTURAL DRAWINGS FOR COLUMN LOCATIONS.7. FEC - INDICATES A FIRE EXTINGUISHER WITH A RECESSED CABINET. FE - INDICATES A FIRE EXTINGUISHER WITH A
WALL MOUNTING BRACKET.8. UNLESS SPECIFICALLY INDICATED OTHERWISE, THE SAME WALL TYPE NEXT TO A DOOR OR OPENING TO
CONTINUE OVER THE DOOR OR OPENING.9. PLAN LOCATION OF DOORS AND FRAMES RELATIVE TO THE PLANE OF THE WALL IS DIAGRAMMATIC ONLY. REFER
TO THE REFERENCED JAMB AND HEAD CONDITION DETAILS TO DETERMINE ACTUAL PLACEMENT OF DOOR AND FRAME.
GENERAL PLAN NOTES
123456789101112131415161718
11720 B
eltsvill
e D
rive
Suite 6
00
Calv
ert
on,
MD
20705
Tel: 3
01.5
95.1
000
123456789101112131415161718
A
B
C
D
E
F
G
H
J
K
L
M
A
B
C
D
E
F
G
H
J
K
L
M
© GRIMM AND PARKER, P.C. 2014
© GRIMM AND PARKER, P.C. 2014
ww
w.g
rim
mandpark
er.
com
PROFESSIONAL CERTIFICATION
I CERTIFY THAT THESE DOCUMENTS
WERE PREPARED OR APPROVED BY
ME, AND I AM A DULY LICENSED
ARCHITECT UNDER THE STATE OF
DELAWARE,
LICENSE NUMBER# 8570
EXPIRATION: 1/31/2022
A102S
SE
CO
ND
FLO
OR
PLA
N 1
/4 S
CA
LE
REHO
BOTH
SPO
TLIG
HT IN
C.41
7 REH
OBOT
H AV
E RE
HOBO
TH B
EACH
, DE
1997
1
4/17/2020PERMIT SUBMISSION
GP #21828.00
1/4" = 1'-0"A10SECOND FLOOR PLAN
N
0 4' 8'2'
DATE DESCRIPTION
CO
NS
OLI
DA
TE
D P
ER
MIT
SE
T 5
/12/
2020
:S
ITE
PLA
N, A
RC
HIT
EC
TU
RA
L P
LAN
S,
SE
CT
ION
S A
ND
ELE
VA
TIO
NS
.*N
OT
FO
R C
ON
ST
RU
CT
ION
*
A16A201S
G11A201S
A14A202S
G9A202S
6' - 0 3/4"
19' -
1 1
/2"
19' -
1 1
/2"
5' -
5"17
' - 8
1/4
"
TOILET
304
TOILET
305
KITCHENETTE
303
PRACTICEROOM
301
THEATRESTUDIO B
308
THEATRESTUDIO A
307
3' -
11 3
/8"
23' - 5" 22' - 5"
2"45' - 10"
70' -
8"
41' - 11"
3' - 11"
5' -
9"5'
- 4"
2' -
8"5'
- 4"
31' -
7"
20' -
0"
70' -
8"
3 5/
16"
7 13
/16"
9' -
0"7'
- 0"
1' -
7 1/
4"7'
- 7
1/4"
8' -
11 3
/4"
9' -
11 1
/4"
BRANCH PANELIT/AV
306
ELEVATOR
ELEV 01
DN
CLOSET
309
LOBBY
302
A501S
A7
A14
A401S
1
A402S
A3
A3
E4
A3
E4
E4
A3
K1
K1
A3
A3
A3
A504S
G5
A505S
H5
STAIR 2
ST2
ROOF
301
309
308
307
S302
306
305
304
302
S301
X309
3' - 0"
2
A402S
X2
SOLID DOOR USED ONLY FOR MAINTENANCE ON THE ROOF
NOT A BALCONY. ACCESS ONLY FOR
MAINTENANCE AND FIRE FIGHTING
24' - 7"
4' -
8"
OPERABLE WALL POCKET FOR FOLDING PARTITION WITH CLOSURE DOOR
D15A501S
DN
8"
6' - 3 5/8" 14' - 0 1/2" 7' - 9 3/8" 5' - 9" 5' - 4 1/2" 2' - 8"
SF15
SF15
SF19SF18
6' -
6"
GENERAL NOTE APPLICABLE TO ALL DRAWINGS - ITEMS AND CONDITIONS DETAILED, NOTED OR OTHERWISE IDENTIFIED ON ONE OF THE SECTIONS OR DETAILS ARE APPLICABLE AND BINDING TO ALL OTHER SECTIONS AND DETAILS FOR IDENTICAL OR SIMILAR CONDITIONS.
1. ALL CONSTRUCTION AND WORK REPRESENTED IN THE COMPLETE SET OF DOCUMENTS IS ASSUMED TO BE NEW AND FURNISHED AND INSTALLED BY THE CONTRACTOR UNLESS OTHERWISE NOTED.
2. IF A CONFLICT EXISTS WITHIN OR BETWEEN DRAWINGS AND SPECIFICATIONS, THE MORE STRINGENT AND MORE COSTLY REQUIREMENT TO APPLY. ITEMS SHOWN ON THE DRAWINGS, BUT NOT SPECIFIED, TO APPLY AND BE PROVIDED BY THE CONTRACTOR. IF AN ITEM IS SHOWN ON THE DRAWINGS, BUT IS NOT INCLUDED IN THE SPECIFICATIONS, PROVIDE ITEM OF A QUALITY LEVEL CONSISTENT WITH THE GENERAL QUALITY LEVEL OF THE CONTRACT REQUIREMENTS. REPORT CONFLICTS BETWEEN THE DRAWINGS AND SPECIFICATIONS TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY.
3. IF A CONFLICT EXISTS BETWEEN DRAWINGS OF DIFFERENT SCALES, CONSULT THE ARCHITECT FOR CLARIFICATION. 4. IN THE ABSENCE OF A WRITTEN DIMENSION, OR IN CASE OF DOUBT AS TO THE PROPER MEASUREMENT, CONSULT THE
ARCHITECT FOR CLARIFICATION. 5. IF AN AREA OR SPACE IS SHOWN, BUT IS NOT CLEARLY DEFINED OR INDICATED BY NOTES, PROVIDE THE SAME
MATERIALS AND FINISHES AS SCHEDULED OR DETAILED FOR AREAS OF SIMILAR USE ELSEWHERE IN THE BUILDING, 6. SECTIONS INDICATED ARE INTENDED TO SHOW THE SPECIFIC CONSTRUCTION WHERE REFERENCED AS WELL AS
ESTABLISH THE GENERAL CONSTRUCTION DETAILS FOR SECTIONS THROUGHOUT THE PROJECT WHICH DO NOT HAVE SPECIFIC SECTIONS DRAWN. THE MOST SIMILAR SECTIONS TO BE ADAPTED TO ANY SECTIONS NOT DETAILED. ANY SPECIFIC QUESTIONS CONCERNING CONSTRUCTION NOT ADEQUATELY COVERED BY THE ABOVE SHOULD BE DIRECTED TO THE ARCHITECT DURING THE BIDDING.
7. TYPICAL DETAILS THROUGHOUT THE DRAWING SET TO APPLY FOR ALL APPLICABLE CONDITIONS EVEN IF NOT SPECIFICALLY SHOWN OR REFERENCED.
8. SEE STRUCTURAL DRAWINGS FOR ACTUAL STRUCTURAL STEEL AND BEARING ELEVATIONS. 9. REFER TO ARCHITECTURAL SITE PLAN FOR THE LAYOUT OF CONCRETE WALKS, MOW STRIPS, PAVING PATTERNS, ETC.
IN THE BUILDING VICINITY. REFER TO CIVIL DRAWINGS FOR THE CONTINUATION OF THIS WORK. 10. AT ALL OUTSIDE CORNERS OF INTERIOR CMU WALLS, COLUMN ENCLOSURES, PIPE CHASES OR OTHER WALL
PROJECTIONS, PROVIDE MASONRY UNITS WITH BULLNOSED (ROUNDED) EDGES WITH 1" RADIUS, UNLESS OTHERWISE NOTED OR WHERE SCHEDULED TO RECEIVE CERAMIC TILE. WHERE MASONRY CORNERS ALIGN WITH BULKHEADS, TRANSITION FROM BULLNOSE CORNER UNITS TO SQUARE CORNER UNITS.
11. UNLESS SPECIFICALLY NOTED OTHERWISE, ENCLOSE ALL VERTICAL MECHANICAL PIPES, RAIN LEADERS, ETC. WITH 4" CMU OR GYPSUM BOARD TO MATCH SURROUNDING FINISHES.
12. REFER TO PLANS AND ELEVATIONS FOR LOCATIONS OF CONTROL JOINTS (C.J.) AND EXPANSION JOINTS (E.J.) IN EXTERIOR MASONRY WALLS. IF A CONFLICT EXISTS BETWEEN JOINT LOCATIONS SHOWN ON THE ELEVATIONS AND PLANS, CONSULT THE ARCHITECT FOR CLARIFICATION PRIOR TO CONSTRUCTION. REFER TO FLOOR PLANS FOR LOCATIONS OF CONTROL JOINTS (C.J.) IN INTERIOR MASONRY WALLS.
13. ALL EXTERIOR CAVITY WALLS TO HAVE CONTINUOUS FLEXIBLE FLASHING AT THE BOTTOM OF THE CAVITY WITH WEEP VENTS TO THE OUTSIDE. ALL FLASHING BUILT INTO WALLS TO BE LAPPED AND SEALED. REFER TO FLASHING DETAILS INDICATED.
14. REFER TO BUILDING ELEVATIONS AND ELEVATION DETAILS FOR MASONRY PATTERNS. 15. INCLUDE PROJECTIONS, BEAM ENCLOSURES, RECESSES, BULKHEADS, PILASTERS AND SIMILAR ENCLOSURES AS PART
OF WALL AND CEILING FINISHES AS SCHEDULED. 16. ALL APPURTENANCES BUILT INTO OR THROUGH WALLS, INCLUDING DOORS, DUCTS, WINDOWS, LOUVERS, GRILLES,
MECHANICAL WORK, ETC. TO FIT TIGHT AND BE THOROUGHLY SEALED AROUND PERIMETERS. WORK AT EXTERIOR WALLS TO BE FLASHED OR OTHERWISE WATERPROOF SEALED.
17. FIELD CHECK ROUGH AND/OR FINISHED DIMENSIONS FOR ACCURATE FITTING OF CABINETS, COUNTERS, LOCKERS, DOORS, WINDOWS, FIXTURES, SHELVING, GATES AND OTHER INSTALLATIONS PRIOR TO SHOP OR FACTORY FABRICATION. PROVIDE FILLER STRIPS, SCRIBE STRIPS, BASES, CLOSURE FINISHES AND TRIM FOR A COMPLETE INSTALLATION.
18. PROVIDE APPROPRIATE TRANSITION STRIPS AT CHANGES IN FLOOR ELEVATIONS. 19. EACH CONTRACTOR MUST REFER TO ALL DRAWINGS AND BE RESPONSIBLE FOR WORK PERTAINING TO THEIR
PARTICULAR TRADE. ALL CONTRACTORS MUST COORDINATE THE WORK OF ALL TRADES AND FIELD CHECK AGAINST ANY CONFLICTS BETWEEN DRAWINGS. REPORT CONFLICTS TO THE ARCHITECT FOR CLARIFICATION.
20. ACCESS PANELS, LOUVER OPENINGS, VENTILATORS, GRILLES, VALVE CABINETS, FIRE DAMPERS OR OTHER APPURTENANCES AFFECTING WALLS, CEILINGS OR FLOORS ARE SHOWN THROUGHOUT THE DRAWINGS. PROVIDE NECESSARY LINTELS, SUPPORT AND ANCHORAGE. SEE STRUCTURAL NOTES FOR LINTEL REQUIREMENTS.
21. REFER TO MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR LOCATIONS OF CONCRETE PADS TO BE PROVIDED BELOW OR AROUND EQUIPMENT.
22. INSTALL ELECTRIC SWITCHES, OUTLETS, THERMOSTATS, CONTROLS, CLOCKS, SPEAKERS, FLAGPOLE HOLDERS AND OTHER WALL-MOUNTED ACCESSORIES IN LOCATIONS WHICH ARE UNOBSTRUCTED BY CABINETS, COUNTERS, RACKS, DISPLAY BOARDS, FIXTURES, SHELVING OR OTHER FURNISHINGS OR EQUIPMENT DESIGNATED FOR SPACES SHOWN ON DRAWINGS. THESE DEVICES MAY BE SHOWN ON THE ARCHITECTURAL DRAWINGS TO ALERT OTHER SUB-CONTRACTORS OF THEIR PRESENCE. COORDINATE INSTALLATION WITH THE ELECTRICAL DRAWINGS. ADVISE THE ARCHITECT OF CONFLICTS IN LOCATION OR TYPES OF DEVICES SHOWN PRIOR TO INSTALLATION. DO NOT INSTALL WALL-MOUNTED ITEMS ON, THROUGH OR INTO ANY EQUIPMENT UNLESS INDICATED.
23. MOUNT ELECTRIC SWITCHES, THERMOSTATS AND OTHER ELECTRONIC CONTROLS LOCATED IN THE SAME VICINITY AT THE SAME HEIGHT ABOVE FINISHED FLOOR IN A UNIFORM, ORDERLY FASHION UNLESS NOTED OTHERWISE.
24. FOR THE PURPOSES OF BIDDING (UNLESS OTHERWISE NOTED), ALL SYMBOLS (LABELED / TAGGED OR UNLABELED/UNTAGGED) WHICH ARE LOCATED ON THE FURNISHING/EQUIPMENT PLANS TO BE CONSIDERED AS IN CONTRACT WORK TO BE PROVIDED BY THE CONTRACTOR. ALL SYMBOLS LOCATED ON THE PLANS DENOTE EITHER FURNITURE, EQUIPMENT, CASEWORK OR MILLWORK. WHERE A SYMBOL IS LOCATED ON THE PLANS BUT IS NOT LABELED OR TAGGED TO A SCHEDULE, THE CONTRACTOR MUST SEEK CLARIFICATION FROM THE OWNER OR ARCHITECT BEFORE PROCEEDING. FOR PURPOSES OF BIDDING ONLY, IF CLARIFICATION CANNOT BE OBTAINED FROM THE OWNER OR ARCHITECT THROUGH ADDENDUM PRIOR TO THE BID DATE, THE CONTRACTOR MUST NEVERTHELESS INCLUDE THE ITEM IN QUESTION IN THEIR BID, CONSIDERING IT THE SAME AS THE TAGGED SYMBOL MOST NEARLY RESEMBLING THE UNTAGGED SYMBOL BASED ON ITS SHAPE, SIZE, LINEWEIGHT(S), LOCATION, AND SCHEDULED USAGE IN SPACES OF SIMILAR FUNCTION. THE CONTRACTOR MUST OBTAIN CLARIFICATION FROM THE ARCHITECT PRIOR TO PROCEEDING WITH SHOP DRAWINGS.
GENERAL NOTES
1. REFER TO SHEET A-301 FOR WALL TYPES AS REFERENCED ON PLANS WITH THE DIAMOND SYMBOL. 2. TYPICAL GYPSUM BOARDS/STUD WALL PARTITION TO BE TYPE J2 UNLESS INDICATED OTHERWISE BY WALL TYPE
SYMBOLS, WALL SECTIONS OR OTHER DETAILS.3. TYPICAL GYPSUM BOARD CHASE WALLS TO BE TYPE X1 UNLESS INDICATED OTHERWISE BY WALL TYPE SYMBOLS,
WALL SECTIONS OR OTHER DETAILS.4. UNLESS NOTED OTHERWISE, WALLS MUST EXTEND TO THE ROOF OR FLOOR DECK ABOVE AND BE SEALED IN
ACCORDANCE WITH THE WALL TERMINATION DETAILS. REFER TO THE CODE STUDY PLAN FOR IDENTIFICATION OF ALL SMOKE AND FIRE WALL CONDITIONS. PERIMETER CORRIDOR AND LOBBY WALLS MUST BE BUILT TO RESIST THE PASSAGE OF SMOKE.
5. DIMENSIONS ON PLANS ARE FROM FACE OF MASONRY TO FACE OF MASONRY, FACE OF MASONRY TO FACE OF GYPSUM BOARD OR FACE OF GYPSUM BOARD TO FACE OF GYPSUM BOARD.
6. COLUMN GRID LINES ARE FOR REFERENCE ONLY, REFER TO STRUCTURAL DRAWINGS FOR COLUMN LOCATIONS.7. FEC - INDICATES A FIRE EXTINGUISHER WITH A RECESSED CABINET. FE - INDICATES A FIRE EXTINGUISHER WITH A
WALL MOUNTING BRACKET.8. UNLESS SPECIFICALLY INDICATED OTHERWISE, THE SAME WALL TYPE NEXT TO A DOOR OR OPENING TO
CONTINUE OVER THE DOOR OR OPENING.9. PLAN LOCATION OF DOORS AND FRAMES RELATIVE TO THE PLANE OF THE WALL IS DIAGRAMMATIC ONLY. REFER
TO THE REFERENCED JAMB AND HEAD CONDITION DETAILS TO DETERMINE ACTUAL PLACEMENT OF DOOR AND FRAME.
GENERAL PLAN NOTES
123456789101112131415161718
11720 B
eltsvill
e D
rive
Suite 6
00
Calv
ert
on,
MD
20705
Tel: 3
01.5
95.1
000
123456789101112131415161718
A
B
C
D
E
F
G
H
J
K
L
M
A
B
C
D
E
F
G
H
J
K
L
M
© GRIMM AND PARKER, P.C. 2014
© GRIMM AND PARKER, P.C. 2014
ww
w.g
rim
mandpark
er.
com
PROFESSIONAL CERTIFICATION
I CERTIFY THAT THESE DOCUMENTS
WERE PREPARED OR APPROVED BY
ME, AND I AM A DULY LICENSED
ARCHITECT UNDER THE STATE OF
DELAWARE,
LICENSE NUMBER# 8570
EXPIRATION: 1/31/2022
A103S
THIR
D F
LOO
R P
LAN
1/4
SC
ALE
REHO
BOTH
SPO
TLIG
HT IN
C.41
7 REH
OBOT
H AV
E RE
HOBO
TH B
EACH
, DE
1997
1
4/17/2020PERMIT SUBMISSION
GP #21828.00
1/4" = 1'-0"A10THIRD FLOOR - STAIR 1 FLOOR PLAN
N
0 4' 8'2'
DATE DESCRIPTION
CO
NS
OLI
DA
TE
D P
ER
MIT
SE
T 5
/12/
2020
:S
ITE
PLA
N, A
RC
HIT
EC
TU
RA
L P
LAN
S,
SE
CT
ION
S A
ND
ELE
VA
TIO
NS
.*N
OT
FO
R C
ON
ST
RU
CT
ION
*
1/4" / 1'-0"
1/4
" / 1
'-0
"
1/4" / 1'-0"
1/4" / 1'-0"
ROOF TOP UNIT
VRV COMPRESSOR
ROOF HATCH
SCUPPER TO GUTTER
SCUPPER TO GUTTER
SCUPPER TO GUTTER
SCUPPER TO GUTTER
SCUPPER TO GUTTER
DOWNSPOUT
DOWNSPOUT
SUNSHADES BELOW
ROOF TYPE 1
10' - 1 1/8"
A15
A105S
ROOF D1SROOF D1S
VRV COMPRESSOR
VRV COMPRESSOR
ROOF D1SROOF D1S
ROOF D1SROOF D1S
5.1" ABOVE ROOF DECK
A9
A105S
TAPERED INSULATION, TYP.
CANOPY
41' - 8"
41' - 8"
43' - 8"
28' - 10"
28' - 10"
41' - 8"
30' - 4"
41' - 8"30' - 4"
EPDM MEMBRANE
1/2" COVERBOARD
4.6" RIGID INSULATION(2 LAYERS OF 2.3" STAGGERED JOINTS
ROOF D1S
ROOF TYPE SCHEDULE SHOWN WITH BASE LAYER OF INSULATION - ALL TAPERED INSULATION ABOVE BASE LAYER
1" METAL ROOF DECK
1/2"
4 5/
8"
1"
6 1/
4"
T.O.M. 48'-0"
BOD 48'-0"
48'-0" J.B.
1
A101
SIM
1
A101
SIM
D.S. 1
D.S. 2
O.S.
ROOF DRAIN WITH TAPERED INSUALTION - TYP. SUMP SHALL BE 4'-0" X 4'-0"
DIRECTION OF SLOPE FROM HIGH POINT - ROOF SLOPES @ 1/4" PER FOOT, MINIMUM, UNLESS OTHERWISE NOTED
TOP OF MASONRY PARAPET
BOTTOM OF DECK
JOIST BEARING
DETAIL @ TOP OF WALL
DETAIL @ LOW ROOF WALL - FLASHING CONDITION
INDICATES ROOFTOP MECHANICAL EQUIPMENT - COORDINATE WITH MECHANICAL DRAWINGS
DOWNSPOUT DOWN TO LOWER ROOF & SPLASH PAN
DOWNSPOUT DOWN TO CAST IRON DOWNSPOUT BOOT AT GRADE - SEE CIVIL DRAWINGS FOR CONNECTION
OVERFLOW SCUPPER
ROOF WALKWAY - 24"X24"X2" CONCRETE PAVERS ON 2" RIGID AT VEGETATIVE ROOF
ROOF WALKWAY - 36" WIDE CAPSHEET ADHERED TO ROOF PER MANUFACTURER'S RECOMMENDATIONS AT LOW SLOPE ROOF.
ROOF SYMBOL KEY
INDICATES SLOPES CREATED BY BUILT-UP CRICKETS OF TAPERED INSULATION
GENERAL NOTE APPLICABLE TO ALL DRAWINGS - ITEMS AND CONDITIONS DETAILED, NOTED OR OTHERWISE IDENTIFIED ON ONE OF THE SECTIONS OR DETAILS ARE APPLICABLE AND BINDING TO ALL OTHER SECTIONS AND DETAILS FOR IDENTICAL OR SIMILAR CONDITIONS.
1. DETAILS INDICATED ARE TYPICAL FOR ALL SIMILAR ROOFING CONDITIONS UNLESS OTHERWISE INDICATED. 2. UNLESS OTHERWISE NOTED, MINIMUM ROOF SLOPE IS 1/4" PER FOOT. PROVIDE TAPERED INSULATION (EVEN IF NOT
SHOWN ON THIS PLAN) AS REQUIRED TO MAINTAIN MINIMUM REQUIRED SLOPE TO ROOF DRAINS AND ELIMINATE ANY AREAS OF POTENTIAL STANDING WATER. PROVIDE TAPERED INSULATION (MINIMUM 1/4" PER FOOT SLOPE) AT ALL CRICKETS INDICATED TO DRAINS. COORDINATE HEIGHTS OF ALL FLASHINGS AND EXPANSION JOINT CAPS WITH TAPERED INSULATION TO MAINTAIN MINIMUM DIMENSIONS DETAILED.
3. ALL ROOF PENETRATIONS AND ACCESSORIES (DRAINS, VENTS, ETC.) ARE TO BE INSTALLED AND FLASHED IN COMPLIANCE WITH THE CURRENT EDITIONS OF N.R.C.A. ROOFING AND WATERPROOFING MANUAL AND S.M.A.C.N.A. (ARCHITECTURAL SHEET METAL MANUAL)
4. COORDINATE WITH MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR ITEMS (INCLUDING UNIT SIZES AND LOCATIONS) NOT SHOWN OR SCHEMATICALLY SHOWN ON ROOF PLANS.
5. CURBS FOR ROOF TOP MECHANICAL EQUIPMENT ARE PROVIDED BY THE MECHANICAL CONTRACTOR. REFER TO TYPICAL CURB FLASHING DETAIL FOR BLOCKING AND FLASHING REQUIREMENTS. PROVIDE ALL BLOCKING NECESSARY TO ACHIEVE LEVEL MECHANICAL CURBS AT ALL LOCATIONS. MAINTAIN MINIMUM 8" FROM TOP OF CURB TO ADJACENT ROOF. PROVIDE TAPERED CRICKETS (MINIMUM 1/2" PER FOOT SLOPE) AROUND ALL MECHANICAL EQUIPMENT CURBS.
6. THE ROOF DRAIN AND MECHANICAL UNIT LOCATIONS SHOWN ON THE ROOF PLAN ARE APPROXIMATE. COORDINATE WITH MECHANICAL AND PLUMBING DRAWINGS FOR EXACT LOCATIONS.
7. PRIOR TO FLASHING OVERFLOW ROOF SCUPPERS AND ROOF DRAIN, ROOFING CONTRACTOR SHALL BE REQUIRED TO CONFIRM MAXIMUM DRAIN PIPE HEIGHT OF 3" ABOVE ROOF IN ACCORDANCE WITH PLUMBING DRAWINGS.
8. START TAPERED INSULATION AT SUMP PLATES. INSULATION SHALL BE TAPERED DOWN FROM ALL (4) SIDES OF INDICATED SUMP. SEE TYPICAL ROOF DRAIN DETAIL.
9. IN ACCORDANCE WITH SPECIFICATION SECTION 07 62 00 SHEET METAL, FLASHING AND TRIM, ROOFING CONTRACTOR SHALL BE REQUIRED TO PROVIDE RECEIVER FLASHING TO MASONRY CONTRACTOR FOR INSTALLATION.
10. PROVIDE WALKWAY PROTECTION WHERE INDICATED AND AT ALL SIDES OF MECHANICAL ROOF TOP UNITS REQUIRING SERVICE AND AT TOP AND BOTTOM OF ALL ROOF STAIRS.
11. ALL ROOF TOP EQUIPMENT (EXCLUDING PREFINISHED ITEMS) SHALL BE FIELD PAINTED. 12. WHERE INDICATED, REFER TO PLUMBING DRAWINGS FOR RADON PIPE DETAIL. FLASHING SHALL BE IN ACCORDANCE WITH
TYPICAL DETAILS.13. CONTRACTOR IS RESPONSIBLE FOR PROVIDING FRT WOOD BLOCKING AS REQUIRED TO ACCOMMODATE ALL PROFILES OF
FINISHED ROOFING INCLUDING AT CRICKETS AND TAPERED INSULATION AT WALLS, PARAPETS AND GRAVEL STOPS. GRAVEL STOPS AT GUTTERS TO BE STAINLESS STEEL WITH SOLDERED JOINTS.
14. COORDINATE HOSE BIB LOCATIONS ON ROOF WITH MEP PLANS. 15. PROVIDE INSULATION THICKNESS AS REQUIRED TO PROVIDE MIN. R-30 CONTINUOUS INSULATION ABOVE ROOF DECK TO
MEET IECC REQUIREMENTS. INSULATION THICKNESS MAY BE REDUCED 1" OR LESS PER IECC SECTION 402.2.2 EXCEPTION #1 PROVIDED THE AREA-WEIGHTED U-FACTOR IS EQUIVALENT TO THE SAME ASSEMBLY WITH THE MINIMUM REQUIRED R-VALUE OVER THE ENTIRETY OF THE ROOF. CONTRACTOR SHALL PROVIDE CALCULATIONS VERIFYING IECC COMPLIANCE.
TYPICAL ROOF NOTES
123456789101112131415161718
11720 B
eltsvill
e D
rive
Suite 6
00
Calv
ert
on,
MD
20705
Tel: 3
01.5
95.1
000
123456789101112131415161718
A
B
C
D
E
F
G
H
J
K
L
M
A
B
C
D
E
F
G
H
J
K
L
M
© GRIMM AND PARKER, P.C. 2014
© GRIMM AND PARKER, P.C. 2014
ww
w.g
rim
mandpark
er.
com
PROFESSIONAL CERTIFICATION
I CERTIFY THAT THESE DOCUMENTS
WERE PREPARED OR APPROVED BY
ME, AND I AM A DULY LICENSED
ARCHITECT UNDER THE STATE OF
DELAWARE,
LICENSE NUMBER# 8570
EXPIRATION: 1/31/2022
A104S
RO
OF
PLA
N 1
/4 S
CA
LE
REHO
BOTH
SPO
TLIG
HT IN
C.41
7 REH
OBOT
H AV
E RE
HOBO
TH B
EACH
, DE
1997
1
4/17/2020PERMIT SUBMISSION
GP #21828.00
1/4" = 1'-0"1ROOF PLAN
N
0 4' 8'2'
DATE DESCRIPTION
CO
NS
OLI
DA
TE
D P
ER
MIT
SE
T 5
/12/
2020
:S
ITE
PLA
N, A
RC
HIT
EC
TU
RA
L P
LAN
S,
SE
CT
ION
S A
ND
ELE
VA
TIO
NS
.*N
OT
FO
R C
ON
ST
RU
CT
ION
*
GENERAL NOTE APPLICABLE TO ALL DRAWINGS - ITEMS AND CONDITIONS DETAILED, NOTED OR OTHERWISE IDENTIFIED ON ONE OF THE SECTIONS OR DETAILS ARE APPLICABLE AND BINDING TO ALL OTHER SECTIONS AND DETAILS FOR IDENTICAL OR SIMILAR CONDITIONS.
1. REFER TO STRUCTURAL DRAWINGS FOR FOOTING ELEVATIONS. 2. MASONRY BOND PATTERN SHALL BE RUNNING BOND UNLESS OTHERWISE INDICATED. REFER TO LARGE SCALE
ELEVATION DETAILS FOR MASONRY PATTERNS, BONDING, SPECIAL SHAPES AND MORTAR COLOR PATTERNS. 3. PROVIDE SEALANT AT ALL INTERSECTIONS OF DISSIMILAR MATERIALS IN ACCORDANCE WITH THE SPECIFICATIONS. ALL
EXTERIOR SEALANTS TO BE A CUSTOM COLOR SELECTED BY THE ARCHITECT. MORE THAN ONE SEALANT COLOR MAY BE SELECTED FOR USE ALONG THE HEIGHT OF THE SAME JOINT TO MATCH ADJOINING MASONRY OR MORTAR.
4. ALL EXTERIOR EXPOSED STEEL TO BE FIELD PAINTED UNLESS NOTED OTHERWISE. COLOR TO BE SELECTED BY THE ARCHITECT.
5. REFER TO SHEET A405S FOR TYPICAL EXTERIOR CONTROL JOINT DETAILS AND NOTES.
(NOTES APPLY TO ALL ELEVATION SHEETS)ELEVATION NOTES
FIRST FLOOR0' - 0"
SECOND FLOOR14' - 0"
PARAPET41' - 8"
THIRD FLOOR27' - 4"
A14
A401S
SUNSCREEN ATTACHED TO STOREFRONT
COVERED CANOPY ABOVE DOORS
SLIDING PANEL
SLIDING PANEL
1' -
8"
1' -
8"
3' - 4"17' - 2"3' - 4"
8' -
4"
1' - 4 1/2"4' - 0"1' - 4"
SF17
SF16SF19
SF18
X309
SF19
CMU3
CMU3
CMU3
CMU1
CMU3
HDMU1
HDMU1ESF20
6' - 3 5/8"
F7
A306S
CJ
X01
LED MONITOR _ SURFACE MOUNTED _ MASONRY TO CONTINUE BEHIND
CJ
ELEVATOR OVER RIDE
PRE-FABRICATED METAL COPING
CJ
LIGHT FIXTURE
FIRST FLOOR0' - 0"
SECOND FLOOR14' - 0"
PARAPET41' - 8"
THIRD FLOOR27' - 4"
1
A402S
FDC
2
A402S
SF14
SF15 SF15CMU3
CMU3
CMU3
CMU3
CMU3
CMU1
HDMU1
HDMU1
CMU1
CMU2CMU2CMU2CMU2
CMU2CMU2CMU2CMU2
X02
SF13
CJ CJCJ
DOWN SPOUT TO CONNECT TO UNDERGROUND STORMWATER
ADA PUSH BUTTON
123456789101112131415161718
11720 B
eltsvill
e D
rive
Suite 6
00
Calv
ert
on,
MD
20705
Tel: 3
01.5
95.1
000
123456789101112131415161718
A
B
C
D
E
F
G
H
J
K
L
M
A
B
C
D
E
F
G
H
J
K
L
M
© GRIMM AND PARKER ARCHITECTURE, INC.
© GRIMM AND PARKER ARCHITECTURE, INC.
ww
w.g
rim
mandpark
er.
com
PROFESSIONAL CERTIFICATION
I CERTIFY THAT THESE DOCUMENTS
WERE PREPARED OR APPROVED BY
ME, AND I AM A DULY LICENSED
ARCHITECT UNDER THE STATE OF
DELAWARE,
LICENSE NUMBER# 8570
EXPIRATION: 1/31/2022
A201S
BU
ILD
ING
ELE
VA
TIO
NS
REHO
BOTH
SPO
TLIG
HT IN
C.41
7 REH
OBOT
H AV
E RE
HOBO
TH B
EACH
, DE
1997
1
4/17/2020PERMIT SUBMISSION
GP #21828.00
1/4" = 1'-0"G11SOUTH ELEVATION
1/4" = 1'-0"A16EAST ELEVATION
G18RENDERING OF SPOTLIGHT
DATE DESCRIPTION
CO
NS
OLI
DA
TE
D P
ER
MIT
SE
T 5
/12/
2020
:S
ITE
PLA
N, A
RC
HIT
EC
TU
RA
L P
LAN
S,
SE
CT
ION
S A
ND
ELE
VA
TIO
NS
.*N
OT
FO
R C
ON
ST
RU
CT
ION
*
FIRST FLOOR0' - 0"
SECOND FLOOR14' - 0"
PARAPET41' - 8"
THIRD FLOOR27' - 4"
1
A402S2
A402S
CJCJCJCJ CMU3
CMU3
CMU3
CMU3
CMU3
CMU1
HDMU1
HDMU1
HDMU1
HDMU1
HDMU1
CMU1
CMU2CMU2CMU2CMU2CMU2CMU2
FIRST FLOOR0' - 0"
SECOND FLOOR14' - 0"
PARAPET41' - 8"
THIRD FLOOR27' - 4"
A14
A401S
X03
CJ
1' - 0 23/32"
7' -
0"
CMU3
CMU3
CMU2CMU2CMU2CMU2
CMU3
CMU3
CMU3
CMU1
CJ
123456789101112131415161718
11720 B
eltsvill
e D
rive
Suite 6
00
Calv
ert
on,
MD
20705
Tel: 3
01.5
95.1
000
123456789101112131415161718
A
B
C
D
E
F
G
H
J
K
L
M
A
B
C
D
E
F
G
H
J
K
L
M
© GRIMM AND PARKER ARCHITECTURE, INC.
© GRIMM AND PARKER ARCHITECTURE, INC.
ww
w.g
rim
mandpark
er.
com
PROFESSIONAL CERTIFICATION
I CERTIFY THAT THESE DOCUMENTS
WERE PREPARED OR APPROVED BY
ME, AND I AM A DULY LICENSED
ARCHITECT UNDER THE STATE OF
DELAWARE,
LICENSE NUMBER# 8570
EXPIRATION: 1/31/2022
A202S
BU
ILD
ING
ELE
VA
TIO
NS
REHO
BOTH
SPO
TLIG
HT IN
C.41
7 REH
OBOT
H AV
E RE
HOBO
TH B
EACH
, DE
1997
1
4/17/2020PERMIT SUBMISSION
GP #21828.00
1/4" = 1'-0"A14WEST ELEVATION
1/4" = 1'-0"G9NORTH ELEVATION
DATE DESCRIPTION
CO
NS
OLI
DA
TE
D P
ER
MIT
SE
T 5
/12/
2020
:S
ITE
PLA
N, A
RC
HIT
EC
TU
RA
L P
LAN
S,
SE
CT
ION
S A
ND
ELE
VA
TIO
NS
.*N
OT
FO
R C
ON
ST
RU
CT
ION
*
FIRST FLOOR0' - 0"
SECOND FLOOR14' - 0"
PARAPET41' - 8"
THIRD FLOOR27' - 4"
DUCTWORK
1
A402S
A403S
A5
SUSPENDED LIGHT
BLACK BOXTHEATRE
109
FIRE PUMP
110
PRACTICE 5
206
THEATRESTUDIO B
308
THEATRESTUDIO A
307
PRACTICE 2
202
LOBBY
208
A404S
G10
A404S
A5
2
A402S
10' -
0"
109B
307 308 301S301
112
AP-4 PANELS, TYPICAL
4' -
0"
8' - 0"4' - 0"
14' -
0"
123456789101112131415161718
11720 B
eltsvill
e D
rive
Suite 6
00
Calv
ert
on,
MD
20705
Tel: 3
01.5
95.1
000
123456789101112131415161718
A
B
C
D
E
F
G
H
J
K
L
M
A
B
C
D
E
F
G
H
J
K
L
M
© GRIMM AND PARKER ARCHITECTURE, INC.
© GRIMM AND PARKER ARCHITECTURE, INC.
ww
w.g
rim
mandpark
er.
com
PROFESSIONAL CERTIFICATION
I CERTIFY THAT THESE DOCUMENTS
WERE PREPARED OR APPROVED BY
ME, AND I AM A DULY LICENSED
ARCHITECT UNDER THE STATE OF
DELAWARE,
LICENSE NUMBER# 8570
EXPIRATION: 1/31/2022
A401S
BU
ILD
ING
SE
CTI
ON
REHO
BOTH
SPO
TLIG
HT IN
C.41
7 REH
OBOT
H AV
E RE
HOBO
TH B
EACH
, DE
1997
1
4/17/2020PERMIT SUBMISSION
GP #21828.00
1/4" = 1'-0"A14BUILDING SECTION1
DATE DESCRIPTION
CO
NS
OLI
DA
TE
D P
ER
MIT
SE
T 5
/12/
2020
:S
ITE
PLA
N, A
RC
HIT
EC
TU
RA
L P
LAN
S,
SE
CT
ION
S A
ND
ELE
VA
TIO
NS
.*N
OT
FO
R C
ON
ST
RU
CT
ION
*
FIRST FLOOR0' - 0"
SECOND FLOOR14' - 0"
PARAPET41' - 8"
THIRD FLOOR27' - 4"
A14
A401S
13' -
4"
14' -
0"
1 3/
4"4'
- 2
1/4"
9' -
0"1
3/4"
4' -
10 1
/4"
9' -
0"
A403S
A10
BLACK BOXTHEATRE
109
TOILET
107
IT/DIMMING
211
TOILET
305
THEATRESTUDIO A
307
LOBBY
105
LOBBY
208
LOBBY
302
A403S
A13
FIRST FLOOR0' - 0"
SECOND FLOOR14' - 0"
PARAPET41' - 8"
THIRD FLOOR27' - 4"
A14
A401S
ROOF38' - 8"
11 2
3/32
"
LOBBY
302
PRACTICE 5
206
ELEV. RM
207
LOBBY
208
FIRE PUMP
110
TOILET
111
LOBBY
105
123456789101112131415161718
11720 B
eltsvill
e D
rive
Suite 6
00
Calv
ert
on,
MD
20705
Tel: 3
01.5
95.1
000
123456789101112131415161718
A
B
C
D
E
F
G
H
J
K
L
M
A
B
C
D
E
F
G
H
J
K
L
M
© GRIMM AND PARKER, P.C. 2014
© GRIMM AND PARKER, P.C. 2014
ww
w.g
rim
mandpark
er.
com
PROFESSIONAL CERTIFICATION
I CERTIFY THAT THESE DOCUMENTS
WERE PREPARED OR APPROVED BY
ME, AND I AM A DULY LICENSED
ARCHITECT UNDER THE STATE OF
DELAWARE,
LICENSE NUMBER# 8570
EXPIRATION: 1/31/2022
A402S
BU
ILD
ING
SE
CTI
ON
REHO
BOTH
SPO
TLIG
HT IN
C.41
7 REH
OBOT
H AV
E RE
HOBO
TH B
EACH
, DE
1997
1
4/17/2020PERMIT SUBMISSION
GP #21828.00
1/4" = 1'-0"1TRANSVERSE SECTION
1/4" = 1'-0"2SECTION AT AT STOREFRONT
DATE DESCRIPTION
CO
NS
OLI
DA
TE
D P
ER
MIT
SE
T 5
/12/
2020
:S
ITE
PLA
N, A
RC
HIT
EC
TU
RA
L P
LAN
S,
SE
CT
ION
S A
ND
ELE
VA
TIO
NS
.*N
OT
FO
R C
ON
ST
RU
CT
ION
*