10
A company of Bayer and LANXESS REFRIGERATION SUPPLY Our sites provide the highest level of supply and quality assurance

REFRIGERATION SUPPLY - CURRENTA · PDF fileREFRIGERATION SUPPLY The refrigeration cycle Refrigeration customer Refrigeration network EXPANSION VALVE Condenser Compressor Evaporator

  • Upload
    lyhuong

  • View
    264

  • Download
    8

Embed Size (px)

Citation preview

Page 1: REFRIGERATION SUPPLY - CURRENTA · PDF fileREFRIGERATION SUPPLY The refrigeration cycle Refrigeration customer Refrigeration network EXPANSION VALVE Condenser Compressor Evaporator

A company of Bayer and LANXESS

REFRIGERATION SUPPLYOur sites provide the highest level of

supply and quality assurance

Page 2: REFRIGERATION SUPPLY - CURRENTA · PDF fileREFRIGERATION SUPPLY The refrigeration cycle Refrigeration customer Refrigeration network EXPANSION VALVE Condenser Compressor Evaporator

CLEAN THE EXTREMEAs an expert service provider, CURRENTA

Environment ensures the smooth running of

production processes at the three sites of

Germany’s largest chemical park in Leverkusen,

Dormagen and Krefeld-Uerdingen.

The company offers its customers, both within and outside CHEMPARK, a customized service portfolio in core fields such as training and further education, infrastructure, safety and security, utilities, waste management, technical services and analytics.We have our own state-of-the-art waste management facilities, an excellent disposal network, reliable water and refrigeration supply, and experienced personnel from the chemical and pharmaceutical industry, all of which enable us to meet the disposal requirements of our customers efficiently and cost-effectively. We supply clean water of the desired quality (drinking, process, cooling or fully desalinated water) and treat your biodegradable wastewater, incinerate and dispose of hazardous waste, and clean containers. We also provide refrigeration for the CHEMPARK sites. We provide advice and support in the construction and operation of waste management facilities and in the collection and recycling of valuable materials. Our portfolio covers individual services and complete solutions that meet the statutory requirements governing the safe disposal of waste and wastewater that is particularly difficult to treat.

02

Page 3: REFRIGERATION SUPPLY - CURRENTA · PDF fileREFRIGERATION SUPPLY The refrigeration cycle Refrigeration customer Refrigeration network EXPANSION VALVE Condenser Compressor Evaporator

LEVERKUSEN

REFRIGERATION SUPPLY FOR COMPANIES AT CHEMPARK

Page 4: REFRIGERATION SUPPLY - CURRENTA · PDF fileREFRIGERATION SUPPLY The refrigeration cycle Refrigeration customer Refrigeration network EXPANSION VALVE Condenser Compressor Evaporator
Page 5: REFRIGERATION SUPPLY - CURRENTA · PDF fileREFRIGERATION SUPPLY The refrigeration cycle Refrigeration customer Refrigeration network EXPANSION VALVE Condenser Compressor Evaporator

Control unit at the G 21 central refrigeration stationin Leverkusen

YOUR CONTACTS

Customer Management Axel WilmsPhone: +49 (0)214 30 72104 E-mail: [email protected]

Customer Management Thomas Müller Phone: +49 (0)214 30 74287 E-mail: [email protected]

Refrigeration Supply Edgar Sunder Phone: +49 (0)214 30 71355 E-mail: [email protected]

3 central refrigeration stationswith a total installed refrigeration capacity of 72 MW

Central refrigeration station G 21 Commissioned: 1969Plant details: 4 turbo compressors, driven by 4 steam turbines Construction/compressors: 1969 - 1972Refrigerating performance: 47.8 MW

Central refrigeration station D 9 Commissioned: 1979Plant details: 1 turbo compressor,driven by 1 steam turbine Construction/compressor: 1978Refrigerating performance: 14.2 MW Plant details: 3 precompressors Refrigerating performance: 1.1 MW

Central refrigeration station C 307 Commissioned: 1998Plant details: 2 rotary screw compressors, driven by 2 electric motors Construction/compressor: 1997Refrigerating performance: 10 MW

Technical characteristics:

CHEMPARK LEV Gas network Liquid network

Celsius: - 5° - 20° - 45°Length in km: 7.4 11.5 0.8 9.5 km

Nominal diameter: up to DN 700 up to DN 200Volume: 3,000 m3 200 m3

Mass: 5.3 t NH3 130 t NH3

05

REFRIGERATION SUPPLY – Leverkusen

Page 6: REFRIGERATION SUPPLY - CURRENTA · PDF fileREFRIGERATION SUPPLY The refrigeration cycle Refrigeration customer Refrigeration network EXPANSION VALVE Condenser Compressor Evaporator

DORMAGEN

REFRIGERATION SUPPLY FOR ALL COMPANIES AT CHEMPARK

Page 7: REFRIGERATION SUPPLY - CURRENTA · PDF fileREFRIGERATION SUPPLY The refrigeration cycle Refrigeration customer Refrigeration network EXPANSION VALVE Condenser Compressor Evaporator

Central refrigeration station B 601

2 central refrigeration stations with a total installed refrigeration capacity of 54.6 MW

Central refrigeration station B 601 Commissioned: 1967 Plant details: 4 turbo compressors, driven by 4 electric motors Construction/compressors: 1968 - 1982 Refrigerating performance: 44.6 MW Special application: Extreme cold -33 °C Plant details: 2 turbo compressors, driven by 2 electric motors Refrigerating performance: 3.4 MW

Central refrigeration station M 72 Commissioned: 2014 Plant details: 3 rotary screw compressors, driven by 3 electric motors Construction/compressors: 2013 Refrigerating performance: 10 MW

Technical characteristics:

CHEMPARK DOR Gas network Liquid network

Celsius: - 5° - 20° - 33°Length in km: 1.2 7.5 0.5 8.1 km

Nominal diameter: up to DN 700 up to DN 150Volume: 1.1 m3 60 m3

Mass: 0.9 t NH3 36.7 t NH3

YOUR CONTACTS

Customer Management Axel WilmsPhone: +49 (0)214 30 72104 E-mail: [email protected]

Customer Management Thomas Müller Phone: +49 (0)214 30 74287 E-mail: [email protected]

Refrigeration Supply Edgar Sunder Phone: +49 (0)214 30 71355 E-mail: [email protected]

07

REFRIGERATION SUPPLY – Dormagen

Page 8: REFRIGERATION SUPPLY - CURRENTA · PDF fileREFRIGERATION SUPPLY The refrigeration cycle Refrigeration customer Refrigeration network EXPANSION VALVE Condenser Compressor Evaporator

08

Page 9: REFRIGERATION SUPPLY - CURRENTA · PDF fileREFRIGERATION SUPPLY The refrigeration cycle Refrigeration customer Refrigeration network EXPANSION VALVE Condenser Compressor Evaporator

THE REFRIGERATION CYCLE

Fig. 1: Refrigeration supply interfaces

09

REFRIGERATION SUPPLY – The refrigeration cycle

Refrigeration customer

Refrigeration network

EXPANSION VALVE

Condenser

Compressor

Evaporator

High pressure

Low pressure

Central refrigeration station

Liquid Gaseous refrigerant

Page 10: REFRIGERATION SUPPLY - CURRENTA · PDF fileREFRIGERATION SUPPLY The refrigeration cycle Refrigeration customer Refrigeration network EXPANSION VALVE Condenser Compressor Evaporator

Published by

Currenta GmbH & Co. OHG

51368 Leverkusen

Germany

www.currenta.com

Last revised: May 2014