1
1. All substrates must be dry, clean, and free of debris and loose foreign materials including oils, grease, and other contaminants. 2. All surfaces must be smooth and free of sharp and protruding edges. 3. RPI Re-Flex TPO Flashing 0embrane must be installed according to RPI TPO System Specifications. Refer to RPI Specification Manual for system installation details. T P O M E M B R A N E RPI RE-FLEX SYSTEMS . EPDM MEMBRANE TPO MEMBRANE COATINGS RPI R OYAL EDGE SYSTEMS . EPDM MEMBRANE . . REFLE; TPO FLUTED CORNER DATA SHEET 53, 5H)OH[ 732 VLQJOHSO\ URRILQJ V\VWHP DFFHVVRULHV SURYLGH URRILQJ FRQWUDFWRUV ZLWK DQ HDV\WRLQVWDOO IDFWRU\EXLOW RU ILHOG IRUPHG GHWDLO DFFHVVRU\ 53, 5H)OH[ DFFHVVRULHV DUH PDQXIDFWXUHG XVLQJ D SURSULHWDU\ IRUPXODWLRQ GHVLJQHG IRU XVH ZLWK 53, 5H)OH[ 732 VLQJOHSO\ KHDW ZHOG DQG WDSHG PHPEUDQH LQVWDOODWLRQV SPECIFICATIONS 0embrane ThicNness mm 'iameter 8 &orners per carton 0 per carton rev 4-16 Information stated on this Roofing Products International, Inc. Data Sheet is intended to provide basic guidance as to storage, application, coverage, shipping, and other product data. Information is subject to change without notice. For more information regarding this product, refer to RPI MSDS, and the RPI Specification Manual. As neither Roofing Products International, Inc. nor its representatives practice structural engineering or architecture, RP I disclaims any responsibility and offers no opinion as to the structural soundness of any structure on which its products may be applied. The building owner should obtain the services of a competent structural engineer before proceeding. RPI accepts no responsibility for any structural failure or resultant damages. No Roofing Products International, Inc. representative is authorized to vary this disclaimer. 57460 Dewitt St. Elkhart, IN 46517 Sales/Technical 1-800-628-2957 Fax: 574-294-3450 www.rpiroyaledge.com RPI Re-Flex TPO Fluted Corner Data Sheet RECOMMENDED STORAGE: 1. Protect membrane from puncture and other physical damage. 2. .eep product protected from weather in original cartons. DESCRIPTION: RPI Re-Flex TPO FlXted &orners are a heat weldable membrane engineered to be installed as part of a premium performance, cost competitive, fully adhered/mechanically attached single ply membrane system that provides a durable, lightweight, puncture and chemical resistant, (nergy Star rated alternative to other low slope roofing systems. RPI Re-Flex TPO FlXted CRrner 0embrane is available in White, Grey, and Tan membranes and may be installed in RPI Re-Flex Heat Welded installatiRns XsinJ .045, .060, and .080 Re- Flex TPO membrane systems. APPLICATION: SHIPPING SPECIFICATIONS :eiJht per cartRn .5 lbs. ManXIactXred tR accRmmRdate imSerIect inside and outside cRrners 'esiJned IRr ease RI ZeldinJ in tiJht areas FlXted CRrners are IRrmed XsinJ XnreinIRrced membrane tR a nRminal 50 mil thicNness CartRns Ser pallet 50

REFLE TPO FLUTED CORNER DATA SHEET - RPI Royal Edge RE-FLEX TPO … · REFLE TPO FLUTED CORNER DATA SHEET SPECIFICATIONS embrane Thicness mm i ameter 8 orners per carton 0 per carton

  • Upload
    others

  • View
    18

  • Download
    0

Embed Size (px)

Citation preview

  • 1. All substrates must be dry, clean, and free of debris and loose foreign materials including oils, grease,and other contaminants.

    2. All surfaces must be smooth and free of sharp and protruding edges.3. RPI Re-Flex TPO Flashing embrane must be installed according to RPI TPO System Specifications.

    Refer to RPI Specification Manual for system installation details.

    TPO MEMBRANE

    RPI RE-FLEX SYSTEMS. EPDM MEMBRANETPO MEMBRANE COATINGS

    RPI ROYAL EDGE SYSTEMS

    RPI .080 RE-FLEX TPO MEMBRANE DATA SHEET

    TPO MEMBRANERPI RE-FLEX SYSTEMS. EPDM MEMBRANE

    TPO MEMBRANE COATINGS

    RPI ROYAL EDGE SYSTEMS. EPDM MEMBRANE..RE FLE TPO FLUTED CORNER DATA SHEET

    SPECIFICATIONSembrane Thic ness mmiameter 8

    orners per carton 0 per carton

    rev 4-16

    Inform ation stated on this Roofing Products International, Inc. Data Sheet is intended to provide basic guidance as to storage, application, coverage, shipping, and other product data. Information is subject to change without notice. For more inform ation regarding this product, refer to RPI MSDS, and the RPI Specification Manual. As neither Roofing Products International, Inc. nor its representatives practice structural engineering or architecture, RP I disclaims any responsibility and offers no opinion as to the structural soundness of any structure on which its products may be applied. The building owner should obtain the services of a competent structural engineer before proceeding. RPI accepts no responsibility for any structural failure or resultant damages. No Roofing Products International, Inc. representative

    is authorized to vary this disclaimer.

    57460 Dewitt St. Elkhart, IN 46517 Sales/Technical 1-800-628-2957 Fax: 574-294-3450

    www.rpiroyaledge.com RPI Re-Flex TPO Fluted Corner Data Sheet

    RECOMMENDED STORAGE:

    1. Protect membrane from puncture and other physical damage.2. eep product protected from weather in original cartons.

    DESCRIPTION:RPI Re-Flex TPO Fl ted orners are a heat weldable membrane engineered to be installed as part of a premium performance, cost competitive, fully adhered/mechanically attached single ply membrane system that provides a durable, lightweight, puncture and chemical resistant, nergy Star rated alternative to other low slope roofing systems. RPI Re-Flex TPO Fl ted C rner embrane is available in White, Grey, and Tan membranes and may be installed in RPI Re-Flex Heat Welded installati ns sin .045, .060, and .080 Re-Flex TPO membrane systems.

    APPLICATION:

    SHIPPING SPECIFICATIONS

    ei ht per cart n .5 lbs.

    • Man act red t acc mm date im er ect inside and outside c rners• esi ned r ease eldin in ti ht areas• Fl ted C rners are rmed sin nrein rced membrane t a n minal 50 mil thic ness

    Cart ns er pallet 50