Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
References of Heat Recovery Boiler Plants
Extraction from the Total List of References of Heat Recovery Boiler Plants
Reference Boiler Plants in total 109
14 Plants thereof as EPC
Reference Plants 109
List of References of Heat Recovery Steam Generators
Page 2 of 2413.10.2020
CCP Plant Hoechst, Frankfurt am Main, GermanyInfraserv GmbH Co. Höchst KG
Gas turbine:
Gas turbine output:
2 x 88,7 MWel
Steam capacity:
2 x 200 t/h
Steam pressure:
123 bar (g)
Steam temperature:
520 °C
Flying take-over:
Auxiliary fuel :
Scope:
Year of commissioning:
CCP Plant Marl VII, GermanySiemens Gas and Power
Gas turbine:
Gas turbine output : 55,3 MWel
Steam capacity: HP
LP22614,4
t/h
Steam pressure: HP
LP80
5,12bar (g)
Steam temperature: HP
LP500150
°C
Flying take-over:
Auxiliary fuel :
Scope:
Year of commissioning:
2021
no
Natural gas, production residues (gaseous)
Boiler Island
Boiler Island
2022
SGT-800
GE 6F.03
yes
Natural gas, production residues (gaseous)
Standardkessel Baumgarte GmbH - A Company of JFE Engineering Group
List of References of Heat Recovery Steam Generators
Page 3 of 2413.10.2020
CCP Plant Marl, GermanySiemens Gas and Power
Gas turbine:
Gas turbine output:
2 x 55,3 MWel
Steam capacity: 2 x HP
2 x LP22614,4
t/h
Steam pressure: HP
LP80
5,12bar (g)
Steam temperature: HP
LP500150
°C
Flying take-over:
Auxiliary fuel :
Scope:
Year of commissioning:
CCP Plant Ineos Cologne, GermanyINEOS Köln GmbH
Gas turbine:
Gas turbine output:
25 MWel
Steam capacity: HP
RH240260
t/h
Steam pressure: HP
RH10832
bar (g)
Steam temperature: HP
RH530510
°C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning :
Boiler Island
2020
GE MS5002E LE
yes
Natural gas, production residues (gaseous), production residues (liquid),
excess gas
Natural gas, production residues (gaseous)
Boiler Island
2021
SGT-800
no
Standardkessel Baumgarte GmbH - A Company of JFE Engineering Group
List of References of Heat Recovery Steam Generators
Page 4 of 2413.10.2020
CCP Plant Palm Paper, King's Lynn, Great BritainPalm Paper Ltd.
Gas turbine:
Gas turbine output:
32,7 MWel
Steam capacity: HP
LP 81
11,2t/ht/h
Steam pressure: HP
LP90 4,2
bar (g)bar (g)
Steam temperature: HP
LP 515145
°C°C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
CHP Plant Flensburg, GermanyStadtwerke Flensburg GmbH
Gas turbine:
Gas turbine output:
50 MWel
Design pressure: HP
LP11010
t/ht/h
Steam pressure: HP
LP758,5
bar (g)bar (g)
Steam temperature: HP
LP525190
°C°C
District heating exchanger part:
Thermal input:
13 MW
Design pressure:
40 bar (g)
Allowable operation temperature:
130 °C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
Boiler Island
2015
SGT-800B
no
Natural gas
Natural gas
Boiler Island
2018
SGT-700
no
Standardkessel Baumgarte GmbH - A Company of JFE Engineering Group
List of References of Heat Recovery Steam Generators
Page 5 of 2413.10.2020
Gas Power Plant Emsland, Lingen, Germany - (Design and detail planning)RWE Power AG
Gas turbine:
Gas turbine output:
2 x 2 à 58 MWel
Steam capacity:
2 x 1140 t/h
Steam pressure:
186,7 bar (g)
Steam temperature:
535 °C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
CCP Plant Hattorf, Philippsthal, GermanyKraftwerk Hattorf GmbH c/o E.ON Energy Projects GmbH
Gas turbine:
Gas turbine output:
32 MWel
Steam capacity:
80 t/h
Steam pressure:
62 bar (g)
Steam temperature:
500 °C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
Natural gas
EPC
2012
2012
SGT-700B
no
no
Natural gas
EPCM
Trent 60 WLE
Standardkessel Baumgarte GmbH - A Company of JFE Engineering Group
List of References of Heat Recovery Steam Generators
Page 6 of 2413.10.2020
CCP Plant Varel B8, Varel, GermanyPapier- und Kartonfabrik Varel GmbH & Co. KG
Gas turbine:
Gas turbine output:
25,6 MWel
Thermal input:
53 MW
Steam capacity:
90 t/h
Steam pressure:
89 bar (g)
Steam temperature:
480 °C
Flying take-over:
Fuel:
Scope:
Year of commissioning:
CHP Plant Linden, Hannover, GermanyStadtwerke Hannover AG
Gas turbine:
Gas turbine output:
77 MWel
Steam capacity: HP
MP9313
t/ht/h
Steam pressure: HP
MP98,131
bar (g)bar (g)
Steam temperature: HP
MP540351
°C°C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
2011
no
no
Boiler Island
Boiler Island
2007
GE PG 6111 FA
Solar T 65 Taurus
no
Natural gas
Standardkessel Baumgarte GmbH - A Company of JFE Engineering Group
List of References of Heat Recovery Steam Generators
Page 7 of 2413.10.2020
CCP Plant Plattling, GermanyKraftwerk Plattling GmbH c/o E.ON Energy Projects GmbH
Gas turbine:
Gas turbine output:
77 MWel
Steam capacity:
201 t/h
Steam pressure:
92 bar (g)
Steam temperature:
532 °C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
CHP Plant Tiefstack, Hamburg, GermanyVattenfall Europe Hamburg AG
Gas turbine:
Gas turbine output:
2 x 51,9 MWel
Steam capacity:
2 x 112 t/h
Steam pressure:
41 bar (g)
Steam temperature:
400 °C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
Boiler Island
2007
Trent 60 DLE
no
Natural gas
Natural gas
Boiler Island
2010
PG 6111FA
no
Standardkessel Baumgarte GmbH - A Company of JFE Engineering Group
List of References of Heat Recovery Steam Generators
Page 8 of 2413.10.2020
CHP Plant Hafen, Münster, GermanyStadtwerke Münster GmbH
Gas turbine:
Gas turbine output:
2 x 34,15 MWel
Steam capacity:
2 x 81,5 t/h
Steam pressure:
82 bar (g)
Steam temperature:
525 °C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
CHP Plant Römerbrücke, Saabrücken, GermanyGDF SUEZ Saarland GmbH (formerly Electrabel Saarland GmbH)
Gas turbine
:
Gas turbine output:
42 MWel
Steam capacity:
115 t/h
Steam pressure:
115 bar (g)
Steam temperature:
535 °C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
Natural gas
Boiler Island
2005
2005
GE-LM 6000
yes
yes
Natural gas / light fuel oil
Boiler Island
RB 211
Standardkessel Baumgarte GmbH - A Company of JFE Engineering Group
List of References of Heat Recovery Steam Generators
Page 9 of 2413.10.2020
DK6 Combined Cycle Plant, Dunkirk, FranceENGIE Thermique France
Gas turbine
:
Gas turbine output:
2 x 160 MWel
Steam capacity per each boiler: HP
RH535530
t/ht/h
Thermal output LP-part:
LP 50 MW
Steam pressure: HP
RH14431
bar (g)bar (g)
Steam temperature: HP
RH566566
°C°C
Flying take-over:
Auxiliary fuel :
Scope:
Year of commissioning:
CHP Plant Würzburg, GermanyThyssenKrupp Xervon Energy
Gas turbine
:
Gas turbine output:
45 MWel
Steam capacity:
125 t/h
Steam pressure:
72 bar (g)
Steam temperature:
515 °C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
Boiler Island
2005
Siemens-SGT 800
yes
Natural gas
Natural gas, blast furnace gas, coke gas
Boiler Island
2004
Alstom-GT 13 E
yes
Standardkessel Baumgarte GmbH - A Company of JFE Engineering Group
List of References of Heat Recovery Steam Generators
Page 10 of 2413.10.2020
CHP Plant Niederrad, GermanyLentjes GmbH (formerly Lurgi GmbH)
Gas turbine
:
Gas turbine output:
47,7 MWel
Steam capacity:
135 t/h
Steam pressure:
69 bar (g)
Steam temperature:
530 °C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
CHP Plant III Duisburg-Wanheim, GermanyLentjes GmbH (formerly AE&E Lentjes GmbH)
Gas turbine:
Gas turbine output:
2 x 77 MWel
Steam capacity:
2 x 96 t/h
Steam pressure:
105 bar (g)
Steam temperature:
533 °C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
no
Boiler Island
2004
2004
GE-PG 6111 (FA)
no
no
Natural gas
Boiler Island
GE-PG 6581 (B)
Standardkessel Baumgarte GmbH - A Company of JFE Engineering Group
List of References of Heat Recovery Steam Generators
Page 11 of 2413.10.2020
Power Plant Grenzach-Wyhlen, Germany E.ON Energy Projects GmbH
Gas turbine:
Gas turbine output:
32,1 MWel
Steam capacity:
80 t/h
Steam pressure:
112 bar (g)
Steam temperature:
525 °C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
Gas Turbine Heating Power Plant Augsburg-Ost, GermanyKraftanlagen Anlagentechnik München GmbH
Gas turbine
:
Gas turbine output:
30,8 MWel
Thermal output boiler:
50 MWth
Design pressure:
22 bar (g)
Flow temperature:
130 °C
Return flow temperature:
58 °C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
2004
no
Natural gas
Boiler Island
EPC
2004
GE-LM 2500 PR DLE
RR-RB 211T
no
Natural gas
Standardkessel Baumgarte GmbH - A Company of JFE Engineering Group
List of References of Heat Recovery Steam Generators
Page 12 of 2413.10.2020
MVV Enamic Ludwigshafen, GermanyMVV Enamic GmbH (formerly MVV Industriekraftwerk Ludwigshafen GmbH)
Gas turbine
:
Gas turbine output:
8,5 MWel
Steam capacity:
25 t/h
Steam pressure:
57 bar (g)
Steam temperature:
455 °C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
CHP Plant Rzeszow, PolandLentjes GmbH (formerly Lurgi Energie und Entsorgung GmbH)
Gas turbine:
Gas turbine output:
61,9 MWel
Steam capacity:
110 t/h
Steam pressure:
98 bar (g)
Steam temperature:
540 °C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
Boiler Island
2003
Siemens-V64.3a
no
no
Natural gas
Boiler Island
2003
Solar-Taurus 70
no
Standardkessel Baumgarte GmbH - A Company of JFE Engineering Group
List of References of Heat Recovery Steam Generators
Page 13 of 2413.10.2020
FBC Plant Grovehurst, Kent, Great BritainLentjes GmbH
Steam capacity:
38,8 t/h
Steam pressure:
26,5 bar (g)
Steam temperature:
345 °C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
CHP Plant Lublin-Wrotków, Lublin, PolandLentjes GmbH (formerly Lurgi Lentjes Energie)
Gas turbine:
Gas turbine output:
155 MWel
Steam capacity:
251 t/h
Steam pressure:
85 bar (g)
Steam temperature:
528 °C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
Boiler Island
2002
Siemens V 94
no
no
no
Boiler Island
2002
no
Standardkessel Baumgarte GmbH - A Company of JFE Engineering Group
List of References of Heat Recovery Steam Generators
Page 14 of 2413.10.2020
CCP Plant Gendorf, Burgkirchen, GermanyInfraserv Bayernwerk Gendorf GmbH
Gas turbine:
Gas turbine output:
43 MWel
Steam capacity:
130 t/h
Steam pressure:
71 bar (g)
Steam temperature:
510 °C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
Power Plant 1+2, Baku, AzerbaijanJacobs Comprimo GmbH
Gas turbine:
Gas turbine output:
2 x 56 MWel
Steam capacity:
2 x 221 t/h
Steam pressure:
20 bar (g)
Steam temperature:
289 °C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
Natural gas
Boiler Island
2001
2002
ABB-GT 8
no
yes
Natural gas, Hydrogen
Boiler Island
SGT-800
Standardkessel Baumgarte GmbH - A Company of JFE Engineering Group
List of References of Heat Recovery Steam Generators
Page 15 of 2413.10.2020
CCP Plant Raubling, GermanyRaubling Papier GmbH, Heinzel Group (formerly Mondi Packaging Raubling GmbH)
Gas turbine:
Gas turbine output:
11,3 MWel
Steam capacity:
85 t/h
Steam pressure:
90 bar (g)
Steam temperature:
502 °C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
YPF Methanol Plant, Plaza Huincul, ArgentinaAir Liquide (formerly Lurgi Öl Gas Chemie GmbH)
Process heat generator:
Energy source:
Thermal input:
67,3 MWth
Gas inlet temperature:
980 °C
Gas outlet temperature:
130 °C
Medium flows:
Scope:
Year of commissioning:
2000
Waste gas
Process gas, steam, fuel gas, air
Boiler Island
EPC
2001
Reformer
Solar-Mars 100
yes
Natural gas, bio gas
Standardkessel Baumgarte GmbH - A Company of JFE Engineering Group
List of References of Heat Recovery Steam Generators
Page 16 of 2413.10.2020
CCP Plant Lachendorf, GermanyDrewsen Spezialpapiere GmbH & Co. KG
Gas turbine:
Gas turbine output:
6,9 MWel
Steam capacity:
65 t/h
Design pressure:
46 bar (g)
Steam temperature:
460 °C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
CCP Plant Wasserburg, GermanyE.ON Energy Projects GmbH
Gas turbine:
Gas turbine output:
6,75 MWel
Steam capacity:
55 t/h
Steam pressure:
64 bar (g)
Steam temperature:
510 °C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
2000
yes
Natural gas
EPC
Natural gas
EPC
2000
Solar-Taurus 70
Solar-Taurus 60
yes
Standardkessel Baumgarte GmbH - A Company of JFE Engineering Group
List of References of Heat Recovery Steam Generators
Page 17 of 2413.10.2020
CHP Lausward, Düsseldorf, GermanyStadtwerke Düsseldrof AG
Gas turbine:
Gas turbine output:
70 MWel
Steam capacity:
103 t/h
Steam pressure:
87 bar (g)
Steam temperature:
541 °C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
CHP Plant Merheim, Cologne, GermanyRheinEnergie AG (formerly: GEW Köln)
Gas turbine:
Gas turbine output:
5 MWel
Steam capacity:
53 t/h
Steam pressure:
85 bar (g)
Steam temperature:
525 °C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
EPC
1999
Solar-Taurus 50
yes
Natural gas, light fuel oil
no
Boiler Island
2000
Siemens-V64
no
Standardkessel Baumgarte GmbH - A Company of JFE Engineering Group
List of References of Heat Recovery Steam Generators
Page 18 of 2413.10.2020
CCP Plant Erfurt-East, GermanySWE Stadtwerke Erfurt GmbH
Gas turbine:
Gas turbine output:
2 x 25 MWel
Steam capacity:
2 x 85 t/h
Steam pressure:
80 bar (g)
Steam temperature:
525 °C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
SVA Neu-Ulm, GermanyThyssenKrupp EnCoke
Steam capacity:
7,9 t/h
Steam pressure:
39 bar (g)
Steam temperature:
400 °C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
Boiler Island
1999
1999
no
no
yes
Natural gas, light fuel oil
EPC
GE-LM 2500
Standardkessel Baumgarte GmbH - A Company of JFE Engineering Group
List of References of Heat Recovery Steam Generators
Page 19 of 2413.10.2020
EPZ AMER 9, Geertruidenberg, The NetherlandsAir Liquide Global E&C Solutions Germany (formerly Lurgi Umwelt)
Energy source:
Steam capacity:
27,1 t/h
Steam pressure:
58 bar (g)
Steam temperature:
320 °C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
PCK Schwedt, Schwedt, GermanyPCK Raffinerie GmbH
Energy source:
Steam capacity:
21,4 t/h
Steam pressure:
36 bar (g)
Steam temperature:
270 °C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
no
Boiler Island
1998
1999
Sewage Water Combustion
no
no
no
Boiler Island
Process gas
Standardkessel Baumgarte GmbH - A Company of JFE Engineering Group
List of References of Heat Recovery Steam Generators
Page 20 of 2413.10.2020
SVZ Schwarze Pumpe, Brandenburg, GermanyLEAG (formerly Schwarze Pumpe GmbH)
Gas turbine:
Gas turbine output:
40 MWel
Steam capacity:
182 t/h
Steam pressure:
96 bar (g)
Steam temperature:
525 °C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
Power Plant Obernburg, GermanyKraftwerk Obernburg GmbH
Gas turbine:
Gas turbine output:
70 MWel
Steam capacity:
130 t/h
Design pressure:
88 bar (g)
Steam temperature:
515 °C
Flying take-over:
Auxiliary fuel :
Scope:
Year of commissioning:
1997
yes
Turbine exhaust gas, natural gas (referred to 8 degree air intake)
Boiler Island
Boiler Island
1997
Siemens-V 64
GE-Frame 6
yes
Light fuel oil, synthetic gas, natural gas, production residues (gaseous)
Standardkessel Baumgarte GmbH - A Company of JFE Engineering Group
List of References of Heat Recovery Steam Generators
Page 21 of 2413.10.2020
CCP Plant Dotternhausen, GermanyHolcim (Süddeutschland) GmbH (formerly Rohrbach Zement GmbH & Co. KG)
Energy source:
Steam capacity:
11,6 t/h
Steam pressure:
58 bar (g)
Steam temperature:
500 °C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
CHP Plant Leipzig-North, GermanyStadtwerke Leipzig GmbH
Gas turbine:
Gas turbine output:
2 x 70 MWel
Steam capacity:
2 x 125 t/h
Design pressure:
85 bar (g)
Steam temperature:
512 °C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
Boiler Island
1996
Siemens-V 64
no
Natural gas
no
Boiler Island
1997
Waste gas downstream rotary furnace
yes
Standardkessel Baumgarte GmbH - A Company of JFE Engineering Group
List of References of Heat Recovery Steam Generators
Page 22 of 2413.10.2020
Europa Carton, Hoya, GermanyAF-Consult Switzerland AG (formerly Colenco AG)
Steam capacity:
45 t/h
Steam pressure:
64 bar (g)
Steam temperature:
450 °C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
Power Plant Schwarzheide, Brandenburg, GermanyBASF SE
Gas turbine:
Gas turbine output:
40,4 MWel
Steam capacity:
2 x 130 t/h
Steam pressure:
80 bar (g)
Steam temperature:
480 °C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
Boiler Island
1995
PG6561 B
no
Natural gas, Fuel oil
no
Boiler Island
1996
no
Standardkessel Baumgarte GmbH - A Company of JFE Engineering Group
List of References of Heat Recovery Steam Generators
Page 23 of 2413.10.2020
CCP Plant Refinery Heide, Hemmingstedt, GermanyShell Deutschland Oil GmbH (formerly DEA)
Gas turbine:
Gas turbine output:
10 MWel
Steam capacity:
135 t/h
Steam pressure:
75 bar (g)
Steam temperature:
520 °C
Flying take-over:
Auxiliary fuel :
Scope:
Year of commissioning:
Power Plant Hamburg, GermanyADM Hamburg AG (formerly Oelmühle Hamburg AG)
Gas turbine:
Gas turbine output:
2 x 6 MWel
Steam capacity:
2 x 65 t/h
Design pressure:
19 bar (g)
Saturated steam temperature:
198 °C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
Natural gas
Boiler Island
1993
1995
RR-Typhoon
no
no
Turbine exhaust gas, gas, heavy fuel oil (referred to 8 degree air intake)
Boiler Island
GE-Frame 3
Standardkessel Baumgarte GmbH - A Company of JFE Engineering Group
List of References of Heat Recovery Steam Generators
Page 24 of 2413.10.2020
CCP Plant Hengelo, The NetherlandsNouryon Industrial Chemicals (formerly Akzo Nobel, before that Salinco)
Gas turbine:
Gas turbine output:
40,5 MWel
Steam capacity:
175 t/h
Design pressure:
103 bar (ü)
Steam temperature:
525 °C
Flying take-over:
Auxiliary fuel:
Scope:
Year of commissioning:
EPC
1993
GE-Frame 6
no
Natural gas
Standardkessel Baumgarte GmbH - A Company of JFE Engineering Group