10
RECORD COPY SIGNED BY MORGAN BYARS 09/01/2011

RECORD COPY SIGNED

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

RECORD COPY SIGNED

BY MORGAN BYARS

09/01/2011

1. THESE CONSTRUCTION DOCUMENTS ARE INTENDEDTO COMPLY WITH APPLICABLE CODES ANDORDINANCES. CONTRACTOR AND SUBCONTRACTORS SHALL COMPLY WITH SAME.

2. ANY DISCREPANCIES BETWEEN CONSTRUCTIONDOCUMENTS AND APPLICABLE CODES ANDORDINANCES SHALL BE BROUGHT TO THE DESIGNER'SATTENTION PRIOR TO STARTING WORK.

3. CONTRACTOR ACCEPTS TOTAL RESPONSIBILITY FORALTERING PLANS IN ANY WAY WITHOUT CONTACTINGDESIGNER.

4. THESE DOCUMENTS DO NOT INCLUDE DETAILS ON ALLASPECTS OF THE CONSTRUCTION AND RELY ON THECONTRACTOR TO USE THE BEST PRACTICES INCONSTRUCTING A BUILDING OF THE HIGHEST QUALITY.

5. ALL COMPONENTS, MATERIALS, ASSEMBLIES ANDFINISHES TO BE CONSTRUCTED AND INSTALLEDACCORDING TO MANUFACTURER'S REQUIREMENTS,CODE COMPLIANCE AND BUILDING SCIENCE BESTPRACTICES.

6. THESE DOCUMENTS ARE NOT INTENDED TO SUGGESTMEANS AND METHODS OF CONSTRUCTION.CONTRACTOR ACCEPTS FULL RESPONSIBILITY FOR ALLASPECTS OF CONSTRUCTION INCLUDING BUT NOTLIMITED TO WATER AND DAMP PROOFING,STRUCTURAL LOAD CONNECTIONS, MECHANICAL,PLUMBING AND ELECTRICAL SYSTEMS.

7. THESE DOCUMENTS DO NOT INCLUDE NECESSARYSAFETY MEANS AND METHODS. CONTRACTOR ISRESPONSIBLE FOR INITIATING, MAINTAINING ANDSUPERVISING SAFETY PROGRAMS, PRECAUTIONS ANDMETHODS FOR COMPLETION OF WORK ANDCOMPLIANCE WITH REQUIREMENTS.

8. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIORTO ORDERING ANY MATERIALS OR COMMENCINGANY WORK. IF DECREPANCIES, OMISSIONS, ORERRORS ARE DISCOVERED, THEY MUST BE BROUGHTTO THE ATTENTION OF THE DESIGNER.

9. DIMENSIONS ARE TO THE FACE OF THE STRUCTURALMEMBER UNLESS OTHERWISE NOTED. DO NOT SCALEANY DIMENSION FROM THESE DOCUMENTS.

10. VERIFY EXISTING CONDITIONS COMPLETELY PRIOR TOSTART OF WORK.

11. CONTRACTOR SHALL VERIFY EGRESS PROVIDED BYWINDOW MANUFACTURER USED AND INSURECOMPLIANCE WITH CODE.

12. CONTRACTOR SHALL VERIFY PLACEMENT OFTEMPERED GLASS WINDOW UNITS TO COMPLY WITHCODE. GLASS IN BATHS AND SHOWER AREAS SHALLBE SAFETY OR LAMINATED TO COMPLY WITH ALLCODES.

13. CONTRACTOR SHALL PROVIDE BLOCKING FOR ALLITEMS TO BE ATTACHED TO THE BUILDING FRAME.THESE ITEMS INCLUDE, BUT ARE NOT LIMITED TO,ELEVATOR MECHANISMS, DOORS, WINDOWS,ACCESS LADDERS, RAILINGS, HANDRAILS,STRUCTURAL LATERAL SUPPORTS, HANDICAPPED RAILSIN BATH ROOMS, CABINETS, TV'S, APPLIANCES,PLUMBING FIXTURES, ELECTRICAL FIXTURES, HVACUNITS AND TRIM.

14. ALIGN DOOR AND WINDOW HEADERS.15. DRAFT STOP ENCLOSED FLOOR SPACES INTO MAX.

1000 SQ. FT. SPACES TO COMPLY WITH CODES.16. FIRE BLOCK AS REQUIRED TO COMPLY WITH CODE.17. PROVIDE VENTILATION IN ATTIC AREAS TO COMPLY

WITH INSULATION TYPE AND CODE.

SQUARE FOOTAGE

CONDITIONED:MAIN LEVEL - 2,514.4 SQ. FT.UPPER LEVEL - 1,665.0 SQ. FT.

TOTAL 4,179.4 SQ. FT.

UNCONDITIONED:GARAGE 737.4 SQ. FT.COVERED PORCH 76.8 SQ. FT.COVERED AREAS 1,196.8 SQ. FT.STORAGE AREAS 2,682.1 SQ. FT.

TOTAL 4,693.1 SQ. FT.

TOTAL GROUND FLOOR 3,864.3 SQ. FT.TOTAL FRAME 5,008.5 SQ. FT.

Josh Albarez
Rectangle Sketch to Scale
14 sf
Josh Albarez
Text Box
MEDICAL 4 SUANA 120V/15amp
Josh Albarez
Cloud
Josh Albarez
Rectangle Sketch to Scale
14 sf
Josh Albarez
Text Box
MEDICAL 4 SUANA 120V/15amp
Josh Albarez
Cloud
Josh Albarez
Length Measurement
6'-2"
Josh Albarez
Rectangle Sketch to Scale
6 sf
Josh Albarez
Line
Josh Albarez
Text Box
C
Josh Albarez
Text Box
L
Josh Albarez
Callout
NEW SINK
Josh Albarez
Cloud
Josh Albarez
Length Measurement
6'-2"
Josh Albarez
Rectangle Sketch to Scale
6 sf
Josh Albarez
Line
Josh Albarez
Text Box
C
Josh Albarez
Text Box
L
Josh Albarez
Callout
NEW SINK
Josh Albarez
Cloud
Josh Albarez
Length Measurement
8'-0"
Josh Albarez
Rectangle Sketch to Scale
2 sf
Josh Albarez
Text Box
WASTE WATER MAIN
Josh Albarez
Cloud
Josh Albarez
Length Measurement
8'-0"
Josh Albarez
Rectangle Sketch to Scale
1 sf
Josh Albarez
Text Box
WASTE WATER MAIN
Josh Albarez
Cloud
Josh Albarez
Length Measurement
11'-5"
Josh Albarez
Length Measurement
29'-10"
Josh Albarez
Polylength Measurement
61'-5"
albar
Area Measurement
201 sf
albar
Area Measurement
858 sf
albar
Area Measurement
1,014 sf
albar
Area Measurement
446 sf
Josh Albarez
Length Measurement
11'-4"

N

N

N

N

N

N

N

N

N

N

N

N

N

N

N N

N

J

N

NOTE:Provide 60 AMP electric service to sub-panel atboat dock by others as well as required switchlegs to control dock lights from inside groundfloor per Owner. Also supply empty 1" conduitfor data line to boat dock.

NOTE:Provide 3/4" Cold Potable Water Line toboat dock by others.

N

N

N

N

N

N

N

N

J

N