•Lumenpackage:–550lumens
@9watts
•Replacementfor50WR20
incandescentlamps
•Fitsintomost4"recessed
downlightfixtures
•CCT:2700K/3000K
•CRIof82
•Dimmable20-100%
•35,000hourlife(L70
)
•Suitableforindooranddamp
locations
•Reducesenergyconsumption
upto82%savings
•120Vinputvoltage
•Lasts14-17timeslongerthan
incandescentandhalogen
lamps
•Nowarm-uptime,instant-on
withfulllightoutputandstable
lamptolampcolor
•MeetsCaliforniaTitle24fixture
requirementsforhighefficacy
luminaire
•Integratedtrimandmedium
basesocketadaptor(included)
fordirectreplacement
The SYLVANIA ULTRA RT4 unit is a four-inch LED recessed downlight
kit creating high performing white light which is optimized for new
construction and retrofit applications. Installation is done quickly and
easily in most standard four-inch Insulated Ceiling (IC), Airtight (AT)
and non-IC housings.
The SYLVANIA ULTRA RT Series recessed downlight kits are
dimmable to 20% with standard 120V electronic low voltage
dimmers (recommended), incandescent or magnetic low voltage
dimmers. In some cases, standard incandescent dimmers require
a minimum load of typically >40 watts on the circuit for full range
dimming performance (four fixtures). For dimming with digital (smart)
multi-location dimmers or when dimming fewer than four LED kits,
Electronic Low Voltage (ELV) dimmers are required (some ELV dim-
mers need a neutral connection in the wallbox).
Ordering Color Abbreviation Wattage TemperatureLED/RT4/550/827/FL80/WTR/WRFL 9 2700KLED/RT4/550/830/FL80/WTR/WRFL 9 3000K
Applications
• Healthcare• Hospitality• Office• Property management• Residential• Retail
Application Information
ULTRA RT4 LEDRecessed Downlight Kit
www.sylvania.com/rt4
Key Features & Benefits
Product Offering
LED218R1 8/11
The SYLVANIA ULTRA RT Series provides good color rendering (82 CRI), and
a selection of color temperatures (2700K, 3000K). LEDs radiate virtually no
UV or heat to damage or fade furnishings, art or other objects.
Engineered optics efficiently direct light output in an 80 degree beam with
low glare.
USC
Specifications and Certifications
Ordering Information
Catalog # Type
Project
Comments
Prepared by Date
LED / RT4 / 550 / 8 27 / FL 80 / WTR / WRFLLED Product Name Light Output CRI=82 Color Temperature Flood Beam Angle White Trim White Reflector RT4; 4=fits 4" diameter (lm) 2700K degrees recessed downlights
Ordering Guide
Specification Data
Nominal Delivered Average Item Ordering Recessed Wattage Light Color Rated Packaging Number Abbreviation Housing (W) Output (lm) Temperature CRI Life (hrs.) Configuration70688 LED/RT4/550/827/FL80/WTR/WRFL 4in. 9 550 2700K 82 35,000 Box70659 LED/RT4/550/830/FL80/WTR/WRFL 4in. 9 550 3000K 82 35,000 Box
Watts RT4 Basic Product LED Saved Life Energy Description Lumens Life Similar Lamp Type Lumens Life With RT4 Benefit Savings Incandescent 50R20 410 2000 41 17x $152RT4 550 35,000 Halogen 50PAR20/WFL 550 2500 41 14x $152 Compact Fluorescent 14R20 495 8000 5 4x $14* Based on $0.11/kWh over 35,000 hrs. life
Energy Savings
Specifications
Input Power: 9W
Input Current: 0.1A
Maximum Ambient Operating Temperature (Insulated Ceiling): 30°C (86°F)
Maximum Ambient Operating Temperature (Non-Insulated Ceiling): 30°C (86°F)
Lighting DataLumen Output: 550
Lumens per Watt: 61
ColorCorrelated Color Temperature (CCT): 2700K-3000K
Color Rendering Index (CRI): 82
Energy DataMinimum Starting Temp: 0°C (32°F)
Sound Rating: <24dBA
Input Voltage: 120V
Power Factor: 0.83
Input Frequency: 60Hz
THD: >20%
Assembly Diagram
1.07 [27]
0.58
[15]
0.96 [24]
0.33 [8]
0.87
[22]
9.26 [235]
SIDE
DIMENSIONS: [MM] INCHES
TOP VIEW
VIEW
GU10 Socket Adaptor70689 LED/RT4/GU10/SOCKET/ADAPTOR (sold separately)
Accessories
DIMENSIONS: [MM] INCHES
10.71272
0.61
16
0.9725
1.0627
0.8121
0.3380.57
14
SIDE VIEW
TOP VIEW
Retrofit Adaptor70657 LED/CRT6/RETROFIT/ADAPTOR (sold separately)
DIMENSIONS: [MM] INCHES
DIMENSIONS: [MM] INCHES
9.00229
1.0426
1.3534
0.6015
TOP VIEW
0.338SIDE VIEW
©2
011
OSRA
MS
YLVA
NIA
8/1
1
SYLVANIA is a registered trademark of OSRAM SYLVANIA Inc.SEE THE WORLD IN A NEW LIGHT is a registered trademark of OSRAM SYLVANIA Inc.OPTOTRONIC is a registered trademark of OSRAM AG.Specifications subject to change without notice.
United StatesOSRAM SYLVANIA 100 Endicott Street Danvers, MA 01923
TradePhone: 1-800-255-5042Fax: 1-800-255-5043
National AccountsPhone: 1-800-562-4671Fax: 1-800-562-4674
OEM/Special MarketsPhone: 1-800-762-7191Fax: 1-800-762-7192
Display/OpticPhone: 1-888-677-2627Fax: 1-800-762-7192
SYLVANIA Lighting ServicesPhone: 1-800-323-0572Fax: 1-800-537-0784
Canada OSRAM SYLVANIA LTD.2001 Drew RoadMississauga, ON L5S 1S4
Trade Phone: 1-800-263-2852Fax: 1-800-667-6772
OEM/Special Markets/Display/OpticPhone: 1-800-265-2852Fax: 1-800-667-6772
SYLVANIA Lighting ServicesPhone: 1-800-663-4268Fax: 1-866-239-1278
MexicoOSRAM MEXICOHeadquartersTultitlan/Edo de Mexico011-52-55-58-99-18-50
www.sylvania.com
Photometric Data
Application Notes
1. Operating temperature range between 32°F and +86°F (0°C and +30°C).
2. Suitable for use in indoor and damp location environments.
3. Suitable for dimmers or in housings controlled by a dimmer – see www.sylvania.com/RT4 for detailed
dimmer compatibility list.
4. Not intended for use with emergency light fixtures or exit lights.
5. For use in housings that can structurally support a lamp weighing one pound.
6. Designed to install in standard 4" insulated and non-insulated housings. For a list of compatible housings,
please refer to www.sylvania.com/RT4.
7. For detailed warranty information, please see www.sylvania.com/RT4.
86
172
257
343
Illuminance (fc) Beam Diameter
SYLVANIA ULTRA RT4 Downlight Retrofit Luminaire
www.sylvania.com/RT4
Manufacturer Compatible CompatiblewithModifications
Halo H99ICTJunoLightingGroup IC1CommercialElectric HBR2000RG401WHP1
SeaGullLighting 11792
ULTRA RT4 Downlight Retrofit Luminaire
Recessed Housing Compatibility List*
LED220
OSRAMSYLVANIA100EndicottStreetDanvers,MA01923USAwww.sylvania.com
© 2
011
OSR
AM S
YLVA
NIA
Th
e in
form
atio
n in
this
doc
umen
t is
subj
ect t
o ch
ange
with
out n
otic
e.
Modification instructions: 1. Remove baffle trim. Use G10 adapter.2. Remove supporting bracket. Remove Edison socket from plate.
*Housing compatibility was determined based on whether the ULTRA RT4 would fit within the identified housing when appropriately modified. The presence of a housing on the compatibility chart is not a guarantee or warranty of the compatibility of the RT4 in any particular installation. The absence of a housing from the compatibility chart does not indicate that the RT4 is not compatible with a particular housing. In any install, the installer should make sure that the RT4 is securely retained in the housing at the time of install.
SYLVANIA ULTRA RT4 and ULTRA RT6 Downlight Retrofit Luminaire
www.sylvania.com
Manufacturer Model Type P/N Max/dimmer
Lutron Skylark® 600WIncandescent S-600P 3 Skylark 600WMagneticLowVoltage SLV-600P 3 Skylark 300WElectronicLowVoltage SELV-300P 3 Diva® 600WIncandescent DV-600P 3 Diva 1000WIncandescent DV-10P 3 Diva 600WMagneticLowVoltage DVLV-600P 3 Diva 300WElectronicLowVoltage DVELV-300P 3 Leviton Illumatech® 600WIncandescent IPI06 3 Trimatron® 600WIncandescent 6683-1W 3 Decora® 600WIncandescent 6631-L 3 Vizia® 600WIncandescent VPI06-1LW 3 Acenti® 600WIncandescent ATI06-1LW 3 Cooper Aspire® 600WIncandescent 9530DS-K 3
ULTRA RT4 and ULTRA RT6 Downlight Retrofit Luminaire
Dimmer Compatibility List*
LED167R1 7/11
OSRAMSYLVANIA100EndicottStreetDanvers,MA01923USAwww.sylvania.com
© 2
011
OSR
AM S
YLVA
NIA
7/1
1 Th
e in
form
atio
n in
this
doc
umen
t is
subj
ect t
o ch
ange
with
out n
otic
e.
*The recommended list is generated from laboratory testing, and the results can vary in certain field applications due to a number of factors. The absence of a dimmer from this chart does not necessarily imply incompatibility. Please reference the dimmer manufacturer’s instructions for installation.
Note: Current dimmer compatibility is based on three lamps per dimmer circuit .
SYLVANIAisaregisteredtrademarkofOSRAMSYLVANIAInc.SEETHEWORLDINANEWLIGHTisaregisteredtrademarkofOSRAMSYLVANIAInc.Allothertrademarksarethoseoftheirrespectiveowners.
1. How much light do the ULTRA RT6 and ULTRA RT4 LED downlights deliver?• RT4 = 550 lumens • RT6 = 625 lumens
2. What are the input wattage and lumens per watt?
• RT4: 550 lumen package = 9W (61LPW) • RT6: 625 lumen package = 11W (61LPW*)
3. What are the color temperatures and the CRI? The ULTRA RT4 and ULTRA RT6 are offered in 2700K
and 3000K with a CRI of 82.
4. What is the expected life rating of the ULTRA RT4 and ULTRA RT6?
The average rated life for the ULTRA RT4 and ULTRA RT6 is 35,000 hours (L70) in Insulated Ceilings (IC), Non-IC, and Airtight**(AT) housings. LED lamp life is defined as the num-ber of hours when 50% of an average group of identical lamps reaches 70% of its initial lumens.
5. What finishes are available? The ULTRA RT4 and ULTRA RT6 come with an integrated
white trim. For additional finishes please contact your SYLVANIA sales professional.
6. Are the ULTRA RT4 and ULTRA RT6 LED downlights dimmable?
Yes, the ULTRA RT4 and ULTRA RT6 are phase-cut dim-mable to 20% of light output. Please note: selected dim-mers can achieve even lower dimming levels. For a compat-ible dimmer list please refer to www.sylvania.com/RT6 or www.sylvania.com/RT4.
ULTRA RT LED Recessed Downlight KitsFAQs
www.sylvania.com
* Product was Lighting Fact Label certified to deliver up to 644 lumens.** Complies with Washington State energy code (WSEC) requirement for airtight.
7. What housings (rough-ins) should be used?
ULTRA RT4 and ULTRA RT6 are compatible with most standard 4" housings and 6" housings with torsion spring brackets, respectively. ULTRA RT6 is not currently compati-ble with commercial housings (i.e. without trim brackets in-side). SYLVANIA will offer an accessory to ensure compati-bility. (See www.sylvania.com/RT6 or www.sylvania.com/RT4 for specific details.)
8. How do I install the ULTRA RT4 and ULTRA RT6 LED downlights?
The ULTRA RT4 and ULTRA RT6 come standard with an Edison based adapter. The ULTRA RT6 comes with torsion springs that can be adjusted to fit your specific housing. The ULTRA RT6 offers a positive fit to ensure proper installation.
LED154R3 11/11
© 2
011
OSR
AM S
YLVA
NIA
11/
11
Cer
tain
Pho
togr
aphy
SYLVANIA is a registered trademark of OSRAM SYLVANIA Inc.SEE THE WORLD IN A NEW LIGHT is a registered trademark of OSRAM SYLVANIA Inc.ENERGY STAR is a registered trademark of the U.S. Government.Specifications subject to change without notice.Photographs are exemplary of possible applications for the lamps and not photographs depicting the lamps in use.
9. Do the ULTRA RT4 and ULTRA RT6 produce a lot of glare?
No, the ULTRA RT4 and ULTRA RT6 blend seamlessly into your ceiling.
10. Do the ULTRA RT4 and ULTRA RT6 meet Title 24 requirements?
Yes, any compatible housing can be used after wire modification is made. For more information please see www.sylvania.com/RT6 or www.sylvania.com/RT4.
11. Are the ULTRA RT4 and ULTRA RT6 LED downlights IC rated for use in insulated ceilings?
Yes.
12. Are the ULTRA RT4 and ULTRA RT6 damp location listed?
Yes, they are damp location listed and can be used in areas that are protected from direct contact with rain (example: shower application).
13. Are the ULTRA RT4 and ULTRA RT6 wet location listed?
No, the ULTRA RT4 and ULTRA RT6 are not wet location listed and cannot be used in unsheltered outdoor areas that are exposed to direct contact with rain, etc.
14. Are the ULTRA RT4 and ULTRA RT6 ENERGY STAR® qualified?
Yes, both the RT4 and RT6 are ENERGY STAR qualified.
15. What are the warranties on the ULTRA RT4 and ULTRA RT6 downlights?
ULTRA RT4 and ULTRA RT6 LED downlights are covered by a three year warranty. For warranty claims or other infor-mation, please contact us at 1-800-LIGHTBULB.
16. What is the Total Harmonic Distortion (THD) of the ULTRA RT4 and ULTRA RT6?
Total Harmonic Distortion of a signal is a measurement of the harmonic distortion present and is defined as the ratio of the sum of the powers of all harmonic components to the power of the fundamental frequency. The THD of the ULTRA RT4 and ULTRA RT6 is 60% at a power factor of 0.81 and will be improved to meet <20% THD. Some California utilities require LED systems to have a THD factor of <20% at full light output to be eligible for utility rebates.
17. Do the ULTRA RT4 and ULTRA RT6 have external power supplies?
The LED driver/power supply is fully integrated in the housing for optimized lumen delivery and superior thermal management of the LED package.
United StatesOSRAM SYLVANIA 100 Endicott Street Danvers, MA 01923
TradePhone: 1-800-255-5042Fax: 1-800-255-5043
National AccountsPhone: 1-800-562-4671Fax: 1-800-562-4674
OEM/Special MarketsPhone: 1-800-762-7191Fax: 1-800-762-7192
Display/OpticPhone: 1-888-677-2627Fax: 1-800-762-7192
SYLVANIA Lighting ServicesPhone: 1-800-323-0572Fax: 1-800-537-0784
www.sylvania.com
Canada OSRAM SYLVANIA LTD.2001 Drew RoadMississauga, ON L5S 1S4
Trade Phone: 1-800-263-2852Fax: 1-800-667-6772
OEM/Special Markets/Display/OpticPhone: 1-800-265-2852Fax: 1-800-667-6772
SYLVANIA Lighting ServicesPhone: 1-800-663-4268Fax: 1-866-239-1278
MexicoOSRAM MEXICOHeadquartersTultitlan/Edo de Mexico011-52-55-58-99-18-50
www.sylvania.com
SYLVANIA ULTRA LED 4” Recessed Kit
Installation Instructions
The SYLVANIA LED recessed kit ULTRA RT4 is designed to install in standard 4” insulated and non-insulated recessed downlight housings. For a list of compatible housings, please refer to www.SYLVANIA.com/RT4.
The ULTRA RT4 LED recessed kit can be dimmed, however updates on dimmer technology and special conditions may apply depending on dimmer type being used. To be assured of the latest information regarding recessed kit and dimmer compatibility, please reference www.SYLVANIA.com/RT4 to find the latest list of compatible dimmers when using multiple ULTRA RT4 recessed kits.
Note: It may be necessary to remove a socket mounting plate for adequate clearance in the compatible housing. Each lampholder shall be installed only in its intended manner and orientation. Not all existing recessed housings that meet these requirements will be compatible with the SYLVANIA ULTRA RT4. To ensure compatibility, a test installation should be conducted.
Minimum distance between edge of recessed kit and top of the housing or other obstruction. (figure 1)
How to install
Important safety information - read all instructions before installation.
Figure 1
1
3.5”
4”
CAUTION:• Turn power off before inspection, installation or removal. • The lamp is suitable for use in damp locations. Use only on 120 VAC, 60Hz circuits. This device complies with Part 15 of the FCC rules and has been tested and found to comply with the limits for a Class B digital device. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,may cause harmful interference to radio communications.
Step 1: Make sure the power is turned off at the source to the recessed housing(s) that you are installing the fixture(s) in. Remove existing trim and CFL, or Incandescent bulbs.
Step 2: Screw Edison base adaptor into socket in recessed housing.
2
• Risk of electrical shock. Disconnect power at fuse or circuit breaker before installing or servicing.• To prevent early lamp failure, lamp should only be installed in operating environments ranging between 0°C and +30°C (32°F and +86°F). • To prevent overheating do not install in totally-enclosed recessed fixtures.• No user serviceable parts inside. To avoid electrical shock do not disassemble product.• This product is not intended for use in emergency light fixtures or exit signs. Not for use where exposed directly to the weather or water. • This product contains a chemical known to the state of California to cause cancer, birth defects or other reproductive harm. • Risk of fire or electrical shock. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings.• Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation. • To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
WARNING
Step 4: Carefully route wires into fixture. Utilizing the friction clips, guide fixture into the housing for a tight fit.
4
Step 3: Plug Edison base cable connector into the LED recessed kit.
Step 5: Push recessed kit up flush to ceiling surface.
5
3
44
SYLVANIA ULTRA LED 4” Kit encastré à DEL
Directives d’installation
Le kit encastré à DEL de 10 cm SYLVANIA ULTRA RT4 a été conçu pour l'installation dans les boîtiers d'éclairage encastrés et orientés vers le bas de 10 cm isolés et non isolés. Pour obtenir la liste des boîtiers compatibles, aller à www.SYLVANIA.com/RT4.
Le kit encastré à DEL ULTRA RT4 peut être relié à un gradateur, mais il pourrait être nécessaire de mod-erniser le gradateur ou encore des conditions particulières pourraient s'appliquer, selon le type de grada-teur employé. Pour obtenir l'information la plus récente sur le kit encastré et la compatibilité avec les gradateurs, aller sur le site www.SYLVANIA.com/RT4, tqui contient la liste à jour des gradateurs compatibles avec des kits encastrés ULTRA RT4 multiples.
Remarque : Il pourrait être nécessaire de retirer la plaque de fixation de la douille pour obtenir le dégage-ment nécessaire dans le boîtier compatible. Chaque douille de lampe doit être installée exclusivement de la façon et avec l'orientation prévus. Les boîtiers encastrés existants qui satisfont à ces exigence ne sont pas tous compatibles avec le kit SYLVANIA ULTRA RT4. Procéder à une installation d'essai afin de confirmer la compatibilité.
Distance minimale entre le bord du kit encastré et le haut du boîtier ou toute autre obstruction. (figure 1)
Installation
Consigne de sécurité - lire toutes les instructions avant l'installation.
Figure 1
1
3.5”
4”
• Mettre hors tension avant l'inspection, l’installation ou le retrait.• La lampe peut être installée dans les endroits humides. Relier uniquement à un circuit de 120 V c.a., 60 Hz.
ATTENTION :
1re étape : S'assurer que le courant est coupé à la source d'alimentation électrique du ou des boîtiers encastrés dans lesquels vous installerez le ou les appareils d'éclairage. Enlever les garnitures existantes et les ampoules CFL ou incandescentes.
2e étape : Visser un adaptateur à culot Edison dans la douille du boîtier encastré.
2
• Risque d’électrocution. Couper l'alimentation électrique au fusible ou au disjoncteur avant d'installer le kit ou de procéder à son entretien. • Afin d’éviter le bris prématuré de la lampe, celle-ci devrait être installée uniquement dans des endroits dont la plage de fonctionnement se situe entre 0°C and +30°C (32°F and +86°F). • Afin d’éviter la surchauffe, ne pas installer dans des appareils d’éclairage encastrés entièrement fermés.• Aucune pièce interne utile pour l’utilisateur. A fin d’éviter de subir des chocs électriques, ne pas démonter ce produit. • Ce produit n’est pas conçu pour être utilisé dans des indicateurs de sortie de secours ou des appareils d’éclairage d’urgence. Non conçu pour être utilisé dans des endroits exposés directement aux intempéries ou à de l’eau. • Ce produit contient une substance chimique reconnue par l’État de Californie comme pouvant causer le cancer, des malformations congénitales ou autres anomalies en matière de procréation. • Risque d'incendie et d'électrocution. Installer cet ensemble uniquement dans les luminaires de modèle et de dimensions indiqués dans les illustrations. • Ne pas faire des trous ou modifier les trous existants sur une enceinte de câblage ou des composants électriques pendant l'installation. • Afin de ne pas les endommager et éviter leur abrasion, ne pas exposer les fils aux rebords des feuilles métalliques ou à d'autres objets tranchants.
AVERTISSEMENT
Cet appareil est conforme aux règles de l’article 15 de la FCC et a été testé et jugé conforme aux limitesétablies pour un appareil numérique de classe B. Ces limites ont été établies afin d’offrir une protectionraisonnable contre les interférences nuisibles dans une installation résidentielle. Cet équipement génère,utilise et peut émettre des fréquences radio et, s’il n’est pas installé et utilisé conformément aux instructions, il peut causer des interférences nuisibles aux communications radio.
4e étape : Acheminer délicatement les fils dans leLuminaire. En utilisant les clips de friction,insérer le Luminaire dans le boîtier pour un ajustement serré.
4
3e étape : Brancher le connecteur de câble Edison dans le kit encastré à DEL.
5e étape : Pousser le kit encastré de façon à ce qu'il affleure avec le plafond.
544
3
El juego de luz de LED empotrada ULTRA RT4 de SYLVANIA está diseñado para instalarse en estructuras estándares de luz hacia abajo empotrada de 4 pulgadas con aislamiento o sin aislamiento. Para ver la lista de las estructuras compatibles, refiérase por favor a www.SYLVANIA.com/RT4.
El juego de luz de LED empotrada ULTRA RT4 puede ser atenuado, sin embargo, pudiera ser necesaria la actualización de la tecnología de atenuación y otras condiciones especiales según el tipo de atenuador empleado. Para asegurarse de conocer la información más reciente sobre la compatibilidad entre el juego de luz empotrada y el atenuador, refiérase por favor a www.SYLVANIA.com/RT4. para ver la lista de los atenuadores compatibles cuando se usen múltiples juegos empotrados ULTRA RT4.
Nota: Pudiera ser necesario retirar la placa de montaje del portalámpara para tener el espacio adecuado en la estructura compatible. Se debe instalar cada portalámpara solamente de la manera y con la orientación recomendada. No todas las estructuras empotradas existentes que cumplen estos requisito son compatibles con el SYLVANIA ULTRA RT4. Para garantizar la compatibilidad, se debe realizar una instalación de prueba.
Distancia mínima entre el borde del juego de luz empotrada y la parte superior de la estructura u otra obstrucción. ( la figura 1)
Cómo instalarlo
Información importante sobre seguridad – lea todas las instrucciones antes de la instalación.
Figura 1
1
3.5”
4”
SYLVANIA ULTRA LED 4” Empotrada en el Kit
Instrucciones para la instalación
Paso 2: Enrosque el adaptador de base Edison en el portalámpara de la estructura empotrada.
2
• Riesgo de descarga eléctrica. Desconecte la corriente en el interruptor de circuito o fusible antes de la instalación o el servicio. • Para evitar fallas tempranas de la lámpara, la lámpara debe ser instalada solamente en entornos operativos que oscilen entre 0°C and +30°C (32°F and +86°F). • Para prevenir recalentar no instala en instalaciones aparatos cerradas.• No contiene piezas que puedan ser reparadas por el usuario. Para evitar choque eléctrico no desmantele el producto.• Este producto no está previsto para utilizar en iluminación de emergencia o en señales de salida.• Not for use where exposed directly to the weather or water.• Este Producto contiene un químico conocido en el estado de California que causan cáncer, defectos de nacimiento u otros daños reproductivos.• Riesgo de incendios o descargas eléctricas. Instale este juego solo en lámparas que tengan las características de construcción y las dimensiones mostradas en las fotografías y/o dibujos”.• No haga orificios ni altere ningún orificio abierto en un receptáculo de alambres o componentes eléctricos durante la instalación del juego”. • Para evitar daños o quemaduras de los alambres, evite el contacto de los alambres con los bordes de hojas de metal u otros objetos afilados.
ADVERTENCIA
PRECAUCION:
• Desconecte la corriente antes de inspeccionar, instalar o desmontar. • La bombilla es adecuada para usarse en lugares húmedos. Uselo solo en circuitos de 120 voltios AC y 60 Hz. Este dispositivo cumple con la Parte 15 de las normas de la FCC y su funcionamiento está sujeto a las dos condiciones siguientes: 1a) Este dispositivo no puede ocasionar daños y 2a) este dispositivo debe aceptar cualquier interferencia recibida, incluyendo la interferencia ocasionada por una operación no deseada. Paso 1: Asegúrese de desconectar la corriente en la fuente de la(s) estructura(s) empotrada(s) en la(s) que va(n) a instalar este(os) juego(s). Retire el reborde y las bombillas fluorescentes compactas o incandescentes existentes.
Paso 1: Asegúrese de desconectar la corriente en la fuente de la(s) estructura(s) empotrada(s) en la(s) que va(n) a instalar este(os) juego(s). Retire el reborde y las bombillas fluorescentes compactas o incandescentes existentes.
Paso 4: Guíe con cuidado los alambres hacia laLámpara. Utilizando los clips de fricción, dirija el sistema de iluminación en la estructura para un ajuste apretado.
4
Paso 3: Enchufe el conector de cable de base Edison al juego de luz de LED empotrada.
Paso 5: Empuje el juego empotrado haciaarriba para que quede a ras con la superficie del techo.
5
3
44