Realize SFC Using ONOS SDN Controller
Mohan Kumar, Senior Software Engineer, Huawei Indian
Cathy Zhang, Principal Architect, Huawei USA
1. Understand OpenStack Neutron SFC Feature: Its Flexible
Architecture to Integrate with Multiple SDN Controllers, Its
APIs, Its Code Status, Second Phase Roadmap.
2. Understand ONOS Controller (Open Network Operating
System) Distributed Architecture For Scalability Support
3. Undertand How Openstack Integrates with ONOS SDN
Controller to Realize the SFC Functionality.
OpenStack Service Chain Overview
What is Service Function Chain ?
Service Chain Management and Control Platform
NAT FW IDS LB Video NAT FW LB
SF
Forwarder
(vSwitch) Cache
QoS
WOC
Classifier Traffic
Destination
Load
Balancer IDS
FW
Traffic
Source
SF
Forwarder
(vSwitch)
OpenStack Neutron Service Chain Architecture
ONOS Controller
ONOS Service Chain
Driver
OVS Service
Chain Driver
Common Service Chain Driver API (C2)
OpenStack API for Service Chain (C1)
Service Chain Driver Manager
OpenStack Server
Compute Node
OVS
Swtich(Classifier)
Service
VM
Service
VM (LB)
Traffic
Source Traffic
Destination
ODL Controller
ODL Service
Chain Driver Dragonflow
Service Chain
Driver
OVN Service
Chain Driver
Dragonflow Controller
OVSDB ETCD Cassandra RamCloud
ONOS Controller
ONOS Service Chain
Driver
OVS Service
Chain Driver
Common Service Chain Driver API (C2)
OpenStack API for Service Chain (C1)
Service Chain Driver Manager
OpenStack Server
Compute Node
OVS
Swtich(Classifier)
Service
VM (FW)
Service
VM (IDS)
Compute Node
OVS Swtich
(Classifier)
Service
VM (NAT) Service
VM(Web)
Traffic
Source Traffic
Destination
ODL Controller
ODL Service
Chain Driver Dragonflow
Service Chain
Driver
OVN Service
Chain Driver
OVN/Dragonflow
Controller
OVSDB ETCD Cassandra RamCloud
OVN/Dragonflow Distributed DB
OpenStack Service Chain API Overview
Flow Classifier
Destination N-Tuple
OpenStack Neutron Service Chain API
Source N-Tuple
Port Pair for IPS1 Neutron Port
for FW1 Neutron Port
for Video Optimizer1
Neutron Port for FW2
Neutron Port for FW3
Traffic
Destination Video
Optimizer
FW IPS
Traffic
Source
Port Pair for IPS2
Neutron Port for Video
Optimizer2
Port-Pair-Group1 Port-Pair-Group2 Port-Pair-Group3
Flow Classifier Flow Classifier
Networking-sfc Project Information
● First Release in Feb 2016 ● Architecture and API Specification Link:
● http://docs.openstack.org/developer/networking-sfc/
● Project Wiki Page: ○ https://wiki.openstack.org/wiki/Neutron/APIForServiceChaining
● Weekly IRC Meeting: ○ Thursday 1700 UTC on #openstack-meeting-4 ○ https://wiki.openstack.org/wiki/Meetings/ServiceFunctionChainin
gMeeting
Second Phase Road Map of Networking-SFC
• Add Support for a Chain of SFs Hosted on
Container
• Add Support for a Chain of SFs Hosted on
Physical Device
• Integrate with VNFM Tacker
• Add ODL SFC Driver, OVN SFC Driver, Dragonflow
SFC Driver to Support the Implementation path on
these Open Source SDN Controllers.
• Support for IETF NSH Encapsulation
• Support for Symmetric SFC Path
ONOS for Openstack
SDN Architecture
OpenStack Networking-SFC
ONOS Controller
vSwitch, Service Function VM/Container/ Physical Device
A new carrier-grade SDN network
operating system designed for
high availability
performance
scale-out.
Mission: “to produce the Open Source
Network Operating System that will
enable service providers to build real
Software Defined Network”
What is Modular ONOS?
SFC in ONOS Architecture
ONOS
Provider
NB API
RESTful
Core
SB API
DEV Link
Switches and Service functions on the Network Data Plane
Apps
PCEP Host
ONOS SFC Manager
ONOS NBI for SFC functions
Vendor Specific
Northbound
Agent
OpenStack Networking-SFC (ONOS SFC Driver)
APP
Southbound
Agent Flow
Net
conf
SB API for SFC provisioning on the device
Host Subsystem
Flow Subsystem
VTN Manager
Device Subsystem
Config Driver
OVSDB
Provider
Demo Topology
VM4 (Destination)
VM3 (SF2) VM1
(Source) VM2 (SF1)
OVS
ingress egress ingress ingress ingress egress egress egress
P1 P2 P3 P4 P5
Packet path before installing SFC VM1 -> VM4
Packet path after installing SFC VM1 -> VM2 -> VM3 -> VM4
P6
● In our demonstration we have source VM, destination VM and a set of service functions VM's spawned using openstack network API
● We use ping packet as data transfer between source and destination. ● Before installing SFC, the packet will directly go to the destination ● After installing SFC the packet will take the defined SFC path and is
processed at each service function before reaching destination.
Scenario 1
VM4 (Destination)
VM3 (SF2) VM1
(Source) VM2 (SF1)
OVS
ingress egress ingress ingress ingress egress egress egress
P1 P2 P3 P4 P5 P6
Test : Ping from VM1 to VM4
Packet path before installing SFC, VM1 -> VM4
20.0.0.3 20.0.0.8
Creating port
● Use neutron networking CLI to create ports on OVS (All ports are created on the same network)
● neutron port-create --name p1 net1
● neutron port-create --name p2 net1
● neutron port-create --name p3 net1
● neutron port-create --name p4 net1
● neutron port-create --name p5 net1
● neutron port-create --name p6 net1
● neutron port-create --name p7 net1
● neutron port-create --name p8 net1
OVS P1 P2 P3 P4 P5 P6
Spawning VM's
● Spawn the VM's with the created ports
● Use nova CLI to spawn the VM's
● nova boot --image cirros-0.3.4-x86_64-uec --flavor m1.small --nic port-id=<ingress port> --nic port-id=<egress port> <vm name>
VM4 (Destination)
VM3 (SF2) VM1
(Source) VM2 (SF1)
OVS
ingress ingress ingress ingress egress egress egress
P1 P2 P3 P4 P5 P
6
egress
Ping from VM1 to VM4 Without SFC
VM4 (Destination)
VM3 (SF2) VM1
(Source) VM2 (SF1)
OVS
ingress egress ingress ingress ingress egress egress egress
P1 P2 P3 P4 P5 P6
Packet path before installing SFC VM1 -> VM4
20.0.0.3 20.0.0.8
Scenario 2
VM4 (Destination)
VM3 (SF2) VM1
(Source) VM2 (SF1)
OVS
ingress egress ingress ingress ingress egress egress egress
P1(27) P2(25) P3(26) P4(28) P5(29) P6(30)
Test : Ping from VM1 to VM4
20.0.0.3 20.0.0.8
Packet path after installing SFC(Create port chain) VM1 -> VM2 -> VM3 -> VM4
Note: 5, 6, 7, 8.. are the OVS ports on which the VM's tap interfaces are created
Creating SFC Port pair
● Use Networking-SFC CLI to create port pairs
● neutron port-pair-create <port pair name> --ingress <port id> --egress <port id>
● When a port pair is successfully created, neutron SFC will send a create request to ONOS rest API.
● ONOS will store the respective port pair details in its DB
Create Port pair PP1 with ports P2 and P3
Create Port pair PP2 with ports P4 and P5
OVS P1 P2 P3 P4 P5 P6
Creating Port pair group
● Use Networking-SFC CLI to create port pair group ● neutron port-pair-group-create --port-pairs <port pair name> <port
pair group name> ● Once the port pair group is successfully created, neutron will send a
create request to ONOS rest API for port pair group. ● ONOS will store the respective port pair details in its DB
Create port pair group PPG1 with port pair PP1
Create port pair group PPG2 with port pair PP2
Create Port pair PP1 with ports P2 and P3
Create Port pair PP2 with ports P5 and P6
OVS P1 P2 P3 P4 P5 P6
Create flow classifier
● Use Networking-SFC CLI to create flow classifier.
● Classifier rule is used to select traffic that originates from source with IP prefix 20.0.0.3/32 and goes to destination with IP prefix 20.0.0.8/32 (Source and destination with in the same network), and the chain ingress port is set as the Source VM’s neutron port p1
● neutron flow-classifier-create --source-ip-prefix 20.0.0.3/32 --destination-ip-prefix 20.0.0.8/32 –logical-source-port p1 FC1
● Once the flow classifier is successfully created, neutron will send a create request to ONOS rest API
● ONOS will store the respective flow classifier details in its DB
Create Port chain
● Use Networking-SFC CLI to create port chain ● Create port chain with VM2 as SF1 and VM3 as SF2 ● neutron port-chain-create --port-pair-group PPG1 --port-pair-
group PPG2 --flow-classifier FC1 <port chain name> ● Once the port chain is successfully created, neutron will send a chain
creation request to ONOS rest API for port chain. ● ONOS will store the respective port chain details in its DB and
initiates event to generate and download required flow rules to the switches for setting up the SFC traffic steering path.
Create Port pair PP1 with ports P2 and P3
Create Port pair PP2 with ports P4 and P5
Create port pair group PPG1 with port pair PP1
Create port pair group PPG2 with port pair PP2
SFC
VM3 (SF2) VM2 (SF1)
ingress egress egress
P2 P3 P4 P5 OVS
ingress
● When the ping packet is coming out from VM1, it will meet the classifier rule and the packet is forwarded to VM2.
● There is a SF1 running in VM2, which will receive the packet, process it and send it out on the VM2’s egress port
● The packet coming out from the Egress port of VM2 will qualify the pre-programmed forwarding rule and be forwarded to VM3.
● There is a SF2 running in VM3, which will receive the packet process it, and send it out on the egress port of VM3
● The packet coming out from Egress port of VM3 will satisfy the normal forwarding rules to the destination, and forwarded to VM4.
VM4 (Destination)
VM3 (SF2) VM1
(Source) VM2 (SF1)
OVS
ingress egress ingress ingress ingress egress egress egress
P1(27) P2(25) P3(26) P4(28) P5(29) P6(30)
Ping from VM1 to VM4 With SFC
Thank You