2
DE-ICING SYSTEM Real instant heat Installing the Batch Heating and/or the Hot At Nozzle systems substantially improve the de-icing operation. Vestergaard Company A/S Skullebjerg 31 • Gevninge DK-4000 Roskilde • Denmark Tel: +45 4642 2222 Fax: +45 4642 2232 [email protected] www.g-vestergaard.dk Vestergaard Company Inc. PO Box 280 McHenry IL 60051 USA Tel: +1 815-759-9102 Fax: +1 815-759-9103 Toll free: +1 888-759-9118 [email protected] MAJOR ADVANTAGES • Immediate spray temperature at the nozzle and no loss of fluid • Environmental and economical optimised • Saves heating of ADF storage tanks Tank 2 Tank 1 Main Batch Real instant heat Fluid diagram Circulation pump Heater Heat exchanger P1 P3 Nozzle Batch Heating Hot at Nozzle When configured so the deicer has built-in purpose designed fuel combustion heating sources - with an extremely high efficiency. This means that the fluid's maximum temperature in the ordinary case will be reached within 20 to 40 minutes - dependent on the heater capacity, tank volume, and initial temperature. BATCH HEATING considerably shortens the time required for obtaining hot fluid - ready for the de-icing. The batch tank is a smaller section within the main tank. The content of the batch tank section will be heated first - in order to reach spraying temperature within a very short time. This will automatically open a valve to the larger tank section the content of which consecutively will be heated. HOT AT NOZZLE ensures hot fluid present out of the spray nozzle by gently circulating fluid in external lines. This option is available for systems with pre-mixed fluids and onboard mixing systems, and prevents spillage of ineffectively cold and expensive AFD.

Real instant heat - Vestergaard Company

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Real instant heat - Vestergaard Company

DE-ICING SYSTEM

Real instant heat

Installing the Batch Heating and/or the Hot At Nozzle systems substantially �improve the de-icing operation.

Vestergaard Company A/SSkullebjerg 31 • GevningeDK-4000 Roskilde • DenmarkTel: +45 4642 2222Fax: +45 4642 [email protected]

Vestergaard Company Inc.PO Box 280McHenry IL 60051 USATel: +1 815-759-9102Fax: +1 815-759-9103Toll free: +1 [email protected]

MAJOR ADVANTAGES

• Immediate spray temperature at thenozzle and no loss of fluid

• Environmental and economical optimised

• Saves heating of ADF storage tanks

Tank 2Tank 1

Main Batch

Real instant heatFluid diagram

Circulationpump

Heater Heatexchanger

P1

P3

Nozzle

Batch Heating Hot at Nozzle

When configured so the deicer has built-in purpose designed fuel combustion heating sources - with an extremely high efficiency. This means that the fluid's maximum temperature in the ordinary case will be reached within 20 to 40 minutes - dependent on the heater capacity, tank volume, and initial temperature.

BATCH HEATING considerably shortens the time required for obtaining hot fluid - ready for the de-icing.

The batch tank is a smaller section within the main tank. The content of the batch tank section will be heated first - in order to reach spraying temperature within a very short time. This will automatically open a valve to the larger tank section the content of which consecutively will be heated.

HOT AT NOZZLE ensures hot fluid present out of the spray nozzle by gently circulating fluid in external lines.

This option is available for systems with pre-mixed fluids and onboard mixing systems, and prevents spillage of ineffectively cold and expensive AFD.

Page 2: Real instant heat - Vestergaard Company

Caution: Specifications are advisory only, and will vary. Please request exact data. 05.03.2004/02

10.01.2004/02

00.0 1.0 2.0 4.0 6.0 8.0 10.0

20

40

60

80

100

120

Batch heatingBeta cycle

Minutes

Tem

p °C

Temp. spray

Temp. Tank 1

Specifications

Heater output (typically): 230 kW or 575 kWHeater thermal efficiency: (> 90%)Performance measures based on standard diesel fuelHeating tube coil of austenitic stainless steelAutomatic fire extinguisher