16
REAL ENERGY COMES FROM ENERGYST

REAL ENERGY COMES TECHNICAL INFORMATION FROM … · 2020. 3. 10. · REAL ENERGY COMES FROM ENERGYST OUR SOLUTIONS POWER SOLUTIONS From a sudden power failure to a planned shutdown,

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

  • WE’D LIKE TO HEAR FROM YOU

    CALL US: 00800 3637 4978EMAIL US: [email protected]

    If you would like to talk to us, request a rental or have a question there are two ways to contact us.

    TECHNICAL INFORMATIONModel XQ75E XQ100E XQ135E XQ150E XQ200E XQ250E XQ275 EU3

    Rating - Prime Prime Prime Prime Prime Prime Prime

    Frequency Hz 50 50 50 50 50 50 50

    Voltage range V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V

    Power capacity1 kVA 75 100 135 150 200 250 275

    kW 60 80 100 120 160 200 220

    Output2 A 108 144 195 217 289 360 398

    Breaker 4P A 160 160 250 250 400 400 630

    Fuel tank ltr 593 766 766 766 1200 1200 668

    Fuel consumption3 l/hr 18.66 23.26 20.9 23.2 31 35.2 48

    Running time hr 32 33 37 33 39 34 14

    Dimensions [LxWxH] mm 2900 x 1155 x 1940 3570 x 1155 x 2030 3570 x 1155 x 2030 3570 x 1155 x 2030 4250 x 1320 x 2445 4250 x 1320 x 2445 4308 x 1500 x 2421

    Weight4 without fuel kg 2160 2540 2810 2810 3980 4110 4080

    Weight4 with fuel kg 2750 3310 3580 3580 5140 5310 4670

    Sound level5 dBA 656 666 62.8 62.8 66.2 66.9 66.5

    POWER GENERATORS 75 - 275 KVA

    1. Performance data quoted in accordance with ISO 8528-1

    2. Amps 50Hz at 400V

    3. Fuel consumption measured at 75% load | fuel density is 850 G/L

    4. Includes oil and coolant, excludes slings

    5. Sound levels given at 75% prime power load 50 Hz at 7m

    6. Data at 100% load

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    REAL ENERGY COMES FROM ENERGYST

  • INTRODUCINGENERGYST.POWERED BYCATERPILLAR

    We are Energyst CAT Rental Power When it comes to equipment hire, we are CAT rental. And if the world’s leading manufacturer of diesel and natural gas engines can trust Energyst with their reputation, it goes without saying that you can rely on us too.

    CONTENTSINTRODUCINGENERGYST.POWERED BYCATERPILLAR

    We are Energyst CAT Rental Power When it comes to equipment hire, we are CAT rental. And if the world’s leading manufacturer of diesel and natural gas engines can trust Energyst with their reputation, it goes without saying that you can rely on us too.

    CONTENTS

    POWER CAN OFTEN BE A MATTER OF LIFE AND DEATH. WHAT IS MORE, UNEXPECTED FAILURES ARE NOT JUST COSTLY IN TERMS OF YOUR FINANCES, THEY MAY ALSO DO UNTOLD DAMAGE TO YOUR REPUTATION. SO WHEN YOU NEED A POWERFUL SOLUTION THAT YOU CAN REALLY RELY ON, IT PAYS TO GET REAL ENERGY FROM ENERGYST.

    Energyst CAT Rental Power is one of the leading providers of power rental solutions. As a subsidiary of Caterpillar dealers and Caterpillar Inc., our extensive range of world class rental equipment includes everything from power generators to load banks.

    We are Energyst CAT Rental PowerWhen it comes to equipment hire, we are CAT rental. And if the world’s leading manufacturer of diesel and natural gas engines can trust Energyst with their reputation, it goes without saying that you can rely on us too.

    OUR SOLUTIONS 3

    POWER GENERATORS 4

    OFFSHORE

    POWER GENERATORS 7

    FUEL TANKS 10

    LOAD BANKS 11

    TRANSFORMERS 12

  • ,

    REAL ENERGY COMES FROM ENERGYST

    OUR SOLUTIONS

    POWERSOLUTIONS

    From a sudden power failure to a

    planned shutdown, temporary power

    for a small-scale project or a long-term

    solution for a mega plant, Energyst can

    help. We have a range of Caterpillar

    generator sets for every power solution.

    From a simple power set up to a multi-

    megawatt installation, our modular

    solutions work together to generate the

    power you need. So if you need 500kVa,

    simply rent four of our 125 kVA units.

    Our power equipment includes:

    • Power Generators up to 2000 kVA

    • Cables

    • Fuel tanks

    • Distribution gear

    • Load banks

    • Transformers

    Our knowledgeable and experienced staff are on hand to answer any questions

    or provide more information about how we can help meet your specifi c needs.

    INTRODUCINGENERGYST.POWERED BYCATERPILLAR

    ,

    REAL ENERGY COMES FROM ENERGYST

    OUR SOLUTIONS

    POWERSOLUTIONS

    From a sudden power failure to a

    planned shutdown, temporary power

    for a small-scale project or a long-term

    solution for a mega plant, Energyst can

    help. We have a range of Caterpillar

    generator sets for every power solution.

    From a simple power set up to a multi-

    megawatt installation, our modular

    solutions work together to generate the

    power you need. So if you need 500kVa,

    simply rent four of our 125 kVA units.

    Our power equipment includes:

    • Power Generators up to 2000 kVA

    • Cables

    • Fuel tanks

    • Distribution gear

    • Load banks

    • Transformers

    Our knowledgeable and experienced staff are on hand to answer any questions

    or provide more information about how we can help meet your specifi c needs.

    INTRODUCINGENERGYST.POWERED BYCATERPILLAR

    ,

    REAL ENERGY COMES FROM ENERGYST

    OUR SOLUTIONS

    POWERSOLUTIONS

    From a sudden power failure to a

    planned shutdown, temporary power

    for a small-scale project or a long-term

    solution for a mega plant, Energyst can

    help. We have a range of Caterpillar

    generator sets for every power solution.

    From a simple power set up to a multi-

    megawatt installation, our modular

    solutions work together to generate the

    power you need. So if you need 500kVa,

    simply rent four of our 125 kVA units.

    Our power equipment includes:

    • Power Generators up to 2000 kVA

    • Cables

    • Fuel tanks

    • Distribution gear

    • Load banks

    • Transformers

    Our knowledgeable and experienced staff are on hand to answer any questions

    or provide more information about how we can help meet your specifi c needs.

    INTRODUCINGENERGYST.POWERED BYCATERPILLAR

    ,

    REAL ENERGY COMES FROM ENERGYST

    OUR SOLUTIONS

    POWERSOLUTIONS

    From a sudden power failure to a

    planned shutdown, temporary power

    for a small-scale project or a long-term

    solution for a mega plant, Energyst can

    help. We have a range of Caterpillar

    generator sets for every power solution.

    From a simple power set up to a multi-

    megawatt installation, our modular

    solutions work together to generate the

    power you need. So if you need 500kVa,

    simply rent four of our 125 kVA units.

    Our power equipment includes:

    • Power Generators up to 2000 kVA

    • Cables

    • Fuel tanks

    • Distribution gear

    • Load banks

    • Transformers

    Our knowledgeable and experienced staff are on hand to answer any questions

    or provide more information about how we can help meet your specifi c needs.

    INTRODUCINGENERGYST.POWERED BYCATERPILLAR

    WHATEVER POWER YOU NEED FOR YOUR INDUSTRIAL FACILITY

    FOR MORE INFORMATION VISIT WWW.ENERGYST.COM

    CALL US: UK 0845 769 7450IE 0035 314 018 580

    EMAIL US: [email protected]@ENERGYST.COM

    • Power Generators up to 2000 kVA• Rigsafe and Norsok Oil & Gas Generators• Cables• Fuel tanks• Distribution gear• Load banks• Transformers

    https://www.energyst.com/uk/power/mailto:[email protected]:[email protected]://www.energyst.com/uk/power/www.energyst.comhttps://www.energyst.com/uk/

  • POWER GENERATORS 75 - 275 KVA

    TECHNICAL INFORMATION

    Caterpillar is the largest producer of medium and high speed diesel engines, and its generators are known worldwide for their safety and reliability. We have temporary generator rental solutions ranging from a simple power set to multi-megawatt installations. It is heavy-duty equipment with low noise and – alongside base load supply – easy to ramp up and down with soft loading and unloading for peaking power.

    Our canopied containers are sound insulated, with super-silent models for extra-sensitive environments. The XQE line provides industry leading fuel effi ciency (up to 20% higher) and excellent performance. Ancillaries ensure your power supply meets the

    highest safety standards, from HV and LV cables and Powerlock connectors to fuel tanks, and 32- to 3200-A distribution boxes.

    Energyst’s fuel-effi cient and low-emission CAT diesel generator solutions: • Form modular systems from 75 to 2000 kVA and above • Produce low diesel and CO2 emissions, meeting or exceeding local and national standards • Come with a standard internal, fully bunded environmentally safe double-walled diesel tank

    1. Performance data quoted in accordance with ISO 8528-1 2. Amps 50Hz at 400V 3. Fuel consumption measured at 75% load | fuel density is 850 G/L 4. Includes oil and coolant, excludes slings 5. Sound levels given at 75% prime power load 50 Hz at 7m 6. Data at 100% load

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    WE’D LIKE TO HEAR FROM YOU

    CALL US: 00800 3637 4978EMAIL US: [email protected]

    If you would like to talk to us, request a rental or have a question there are two ways to contact us.

    TECHNICAL INFORMATIONModel XQ75E XQ135E XQP150 EUIIIA XQ150E XQ250E XQ275 EUIIIA

    Rating - Prime Prime Prime Prime Prime Prime

    Frequency Hz 50 50 50 50 50 50

    Voltage range V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V

    Power capacity1 kVA 75 135 150 150 250 275

    kW 60 100 120 120 200 220

    Output2 A 108 195 217 217 360 398

    Breaker 4P A 160 250 250 250 400 630

    Fuel tank ltr 593 766 590 766 1200 668

    Fuel consumption3 l/hr 18.66 20.9 29.6 23.2 35.2 48

    Running time hr 32 37 20 33 34 14

    Dimensions [LxWxH] mm 2900 x 1155 x 1940 3570 x 1155 x 2030 3520 x 1120 x 2226 3570 x 1155 x 2030 4250 x 1320 x 2445 4308 x 1500 x 2421

    Weight4 without fuel kg 2160 2810 2547 2810 4110 4080

    Weight4 with fuel kg 2750 3580 3124 3580 5310 4670

    Sound level5 dBA 656 62.8 64 62.8 66.9 66.5

    POWER GENERATORS 75 - 275 KVA

    1. Performance data quoted in accordance with ISO 8528-1

    2. Amps 50Hz at 400V

    3. Fuel consumption measured at 75% load | fuel density is 850 G/L

    4. Includes oil and coolant, excludes slings

    5. Sound levels given at 75% prime power load 50 Hz at 7m

    6. Data at 100% load

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    V7 /

    12.1

    6 / E

    NER

    GYS

    T

    Our heat pump rental solutions are stand-alone, closed packaged systems. They can supply hot and cold water that is transported through flexible high-pressure hoses to distribution devices.

    All our units have a standard design to make assembly, disassembly, installation and maintenance quick and easy. They are easy to transport with a forklift or a crane. They of course come complete with all the ancillaries and fittings you’ll need – like electric cables and water hoses.

    STAND-ALONE & EFFICIENT HEAT PUMP RENTAL

    ENERGYST HEAT PUMPSSPECIFICATION

    HEAT PUMPS 100-300 KW

    INSTANT GENERATOR RENTAL – FROM A FEW KW UP TO MULTI MEGAWATTS

    75 - 275 KVAPOWER GENERATORS 75 - 275 KVA

    TECHNICAL INFORMATION

    Caterpillar is the largest producer of medium and high speed diesel engines, and its generators are known worldwide for their safety and reliability. We have temporary generator rental solutions ranging from a simple power set to multi-megawatt installations. It is heavy-duty equipment with low noise and – alongside base load supply – easy to ramp up and down with soft loading and unloading for peaking power.

    Our canopied containers are sound insulated, with super-silent models for extra-sensitive environments. The XQE line provides industry leading fuel effi ciency (up to 20% higher) and excellent performance. Ancillaries ensure your power supply meets the

    highest safety standards, from HV and LV cables and Powerlock connectors to fuel tanks, and 32- to 3200-A distribution boxes.

    Energyst’s fuel-effi cient and low-emission CAT diesel generator solutions: • Form modular systems from 75 to 2000 kVA and above • Produce low diesel and CO2 emissions, meeting or exceeding local and national standards • Come with a standard internal, fully bunded environmentally safe double-walled diesel tank

    1. Performance data quoted in accordance with ISO 8528-1 2. Amps 50Hz at 400V 3. Fuel consumption measured at 75% load | fuel density is 850 G/L 4. Includes oil and coolant, excludes slings 5. Sound levels given at 75% prime power load 50 Hz at 7m 6. Data at 100% load

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    WE’D LIKE TO HEAR FROM YOU

    CALL US: 00800 3637 4978EMAIL US: [email protected]

    If you would like to talk to us, request a rental or have a question there are two ways to contact us.

    TECHNICAL INFORMATIONModel XQ75E XQ135E XQP150 EUIIIA XQ150E XQ250E XQ275 EUIIIA

    Rating - Prime Prime Prime Prime Prime Prime

    Frequency Hz 50 50 50 50 50 50

    Voltage range V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V

    Power capacity1 kVA 75 135 150 150 250 275

    kW 60 100 120 120 200 220

    Output2 A 108 195 217 217 360 398

    Breaker 4P A 160 250 250 250 400 630

    Fuel tank ltr 593 766 590 766 1200 668

    Fuel consumption3 l/hr 18.66 20.9 29.6 23.2 35.2 48

    Running time hr 32 37 20 33 34 14

    Dimensions [LxWxH] mm 2900 x 1155 x 1940 3570 x 1155 x 2030 3520 x 1120 x 2226 3570 x 1155 x 2030 4250 x 1320 x 2445 4308 x 1500 x 2421

    Weight4 without fuel kg 2160 2810 2547 2810 4110 4080

    Weight4 with fuel kg 2750 3580 3124 3580 5310 4670

    Sound level5 dBA 656 62.8 64 62.8 66.9 66.5

    POWER GENERATORS 75 - 275 KVA

    1. Performance data quoted in accordance with ISO 8528-1

    2. Amps 50Hz at 400V

    3. Fuel consumption measured at 75% load | fuel density is 850 G/L

    4. Includes oil and coolant, excludes slings

    5. Sound levels given at 75% prime power load 50 Hz at 7m

    6. Data at 100% load

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    V7 /

    12.1

    6 / E

    NER

    GYS

    T

    Our heat pump rental solutions are stand-alone, closed packaged systems. They can supply hot and cold water that is transported through flexible high-pressure hoses to distribution devices.

    All our units have a standard design to make assembly, disassembly, installation and maintenance quick and easy. They are easy to transport with a forklift or a crane. They of course come complete with all the ancillaries and fittings you’ll need – like electric cables and water hoses.

    STAND-ALONE & EFFICIENT HEAT PUMP RENTAL

    ENERGYST HEAT PUMPSSPECIFICATION

    HEAT PUMPS 100-300 KW

    INSTANT GENERATOR RENTAL – FROM A FEW KW UP TO MULTI MEGAWATTS

    75 - 275 KVA

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    60 Hz versions available on request.

    The majority of our generators is equipped with remote monitoring.

    1. Performance data quoted in accordance with ISO 8528-1 2. Amps 50Hz at 400V, 60Hz at 480V 3. Fuel consumption measured at 75% load. Fuel density is 850 G/L 4. Includes oil and coolant, excludes slings.

    5. Sound levels given at 75% prime power load 50 Hz at 7m, Sound data 60 Hz is estimated 2 dBa more than 50 Hz based on bare engine data.

    6. Design data 7. Data at 100% load

    WE’D LIKE TO HEAR FROM YOU

    CALL US: 00800 3637 4978EMAIL US: [email protected]

    If you would like to talk to us, request a rental or have a question there are two ways to contact us.

    TECHNICAL INFORMATIONModel XQ75E XQ135E XQ150E XQ250E

    Rating - Prime Prime Prime Prime Prime Prime

    Frequency Hz 50 50 50 50 50 50

    Voltage range V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V

    Power capacity1 kVA 75 135 150 150 250 275

    kW 60 100 120 120 200 220

    Output2 A 108 195 217 217 360 398

    Breaker 4P A 160 250 250 250 400 630

    Fuel tank ltr 593 766 590 766 1200 668

    Fuel consumption3 l/hr 18.67 20.9 29.6 23.2 35.2 48

    Running time hr 32 37 20 33 34 14

    Dimensions [LxWxH] mm 2900 x 1155 x 1940 3570 x 1155 x 2030 3520 x 1120 x 2226 3570 x 1155 x 2030 4250 x 1320 x 2445 4308 x 1500 x 2421

    Weight4 without fuel kg 2160 2810 2547 2810 4110 4080

    Weight4 with fuel kg 2750 3580 3124 3580 5310 4670

    Sound level5 dBA 657 62.8 64 62.8 66.9 66.5

    POWER GENERATORS 75 - 275 KVA

    1. Performance data quoted in accordance with ISO 8528-1

    2. Amps 50Hz at 400V

    3. Fuel consumption measured at 75% load | fuel density is 850 G/L

    4. Includes oil and coolant, excludes slings

    5. Sound levels given at 75% prime power load 50 Hz at 7m

    6. Data at 100% load

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    V7 /

    12.1

    6 / E

    NER

    GYST

    WE’D LIKE TO HEAR FROM YOU

    CALL US: 00800 3637 4978EMAIL US: [email protected]

    If you would like to talk to us, request a rental or have a question there are two ways to contact us.

    TECHNICAL INFORMATIONModel XQ75E XQ135E XQ150E XQ250E

    Rating - Prime Prime Prime Prime Prime Prime

    Frequency Hz 50 50 50 50 50 50

    Voltage range V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V

    Power capacity1 kVA 75 135 150 150 250 275

    kW 60 100 120 120 200 220

    Output2 A 108 195 217 217 360 398

    Breaker 4P A 160 250 250 250 400 630

    Fuel tank ltr 593 766 590 766 1200 668

    Fuel consumption3 l/hr 18.67 20.9 29.6 23.2 35.2 48

    Running time hr 32 37 20 33 34 14

    Dimensions [LxWxH] mm 2900 x 1155 x 1940 3570 x 1155 x 2030 3520 x 1120 x 2226 3570 x 1155 x 2030 4250 x 1320 x 2445 4308 x 1500 x 2421

    Weight4 without fuel kg 2160 2810 2547 2810 4110 4080

    Weight4 with fuel kg 2750 3580 3124 3580 5310 4670

    Sound level5 dBA 657 62.8 64 62.8 66.9 66.5

    POWER GENERATORS 75 - 275 KVA

    1. Performance data quoted in accordance with ISO 8528-1

    2. Amps 50Hz at 400V

    3. Fuel consumption measured at 75% load | fuel density is 850 G/L

    4. Includes oil and coolant, excludes slings

    5. Sound levels given at 75% prime power load 50 Hz at 7m

    6. Data at 100% load

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    V7 /

    12.1

    6 / E

    NER

    GYST

    1 Performance data quoted in accordance with ISO 8528-1

    2 Amps 50Hz at 400V, 60Hz at 480V

    3 Fuel consumption measured at 75% load. Fuel density is 850 G/L

    4 includes oil and coolant, excludes slings.

    5 Sound levels given at 75% prime power load 50 Hz at 7m, Sound data 60 hz is estimated 2 dBa more then 50 hz based on bare engine data.

    6 Design data

    7 Data at 100% load

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    60 Hz versions available on request

    The majority of our rental solutions is equipped with remote monitoring.

    WE’D LIKE TO HEAR FROM YOU

    CALL US: 00800 3637 4978EMAIL US: [email protected]

    If you would like to talk to us, request a rental or have a question there are two ways to contact us.

    TECHNICAL INFORMATIONModel XQ75E XQ135E XQ150E XQ250E

    Rating - Prime Prime Prime Prime Prime Prime

    Frequency Hz 50 50 50 50 50 50

    Voltage range V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V

    Power capacity1 kVA 75 135 150 150 250 275

    kW 60 100 120 120 200 220

    Output2 A 108 195 217 217 360 398

    Breaker 4P A 160 250 250 250 400 630

    Fuel tank ltr 593 766 590 766 1200 668

    Fuel consumption3 l/hr 18.67 20.9 29.6 23.2 35.2 48

    Running time hr 32 37 20 33 34 14

    Dimensions [LxWxH] mm 2900 x 1155 x 1940 3570 x 1155 x 2030 3520 x 1120 x 2226 3570 x 1155 x 2030 4250 x 1320 x 2445 4308 x 1500 x 2421

    Weight4 without fuel kg 2160 2810 2547 2810 4110 4080

    Weight4 with fuel kg 2750 3580 3124 3580 5310 4670

    Sound level5 dBA 657 62.8 64 62.8 66.9 66.5

    POWER GENERATORS 75 - 275 KVA

    1. Performance data quoted in accordance with ISO 8528-1

    2. Amps 50Hz at 400V

    3. Fuel consumption measured at 75% load | fuel density is 850 G/L

    4. Includes oil and coolant, excludes slings

    5. Sound levels given at 75% prime power load 50 Hz at 7m

    6. Data at 100% load

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    V7 /

    12

    .16 /

    EN

    ER

    GYS

    T

    WE’D LIKE TO HEAR FROM YOU

    CALL US: 00800 3637 4978EMAIL US: [email protected]

    If you would like to talk to us, request a rental or have a question there are two ways to contact us.

    TECHNICAL INFORMATIONModel XQ75E XQ135E XQ150E XQ250E

    Rating - Prime Prime Prime Prime Prime Prime

    Frequency Hz 50 50 50 50 50 50

    Voltage range V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V

    Power capacity1 kVA 75 135 150 150 250 275

    kW 60 100 120 120 200 220

    Output2 A 108 195 217 217 360 398

    Breaker 4P A 160 250 250 250 400 630

    Fuel tank ltr 593 766 590 766 1200 668

    Fuel consumption3 l/hr 18.67 20.9 29.6 23.2 35.2 48

    Running time hr 32 37 20 33 34 14

    Dimensions [LxWxH] mm 2900 x 1155 x 1940 3570 x 1155 x 2030 3520 x 1120 x 2226 3570 x 1155 x 2030 4250 x 1320 x 2445 4308 x 1500 x 2421

    Weight4 without fuel kg 2160 2810 2547 2810 4110 4080

    Weight4 with fuel kg 2750 3580 3124 3580 5310 4670

    Sound level5 dBA 657 62.8 64 62.8 66.9 66.5

    POWER GENERATORS 75 - 275 KVA

    1. Performance data quoted in accordance with ISO 8528-1

    2. Amps 50Hz at 400V

    3. Fuel consumption measured at 75% load | fuel density is 850 G/L

    4. Includes oil and coolant, excludes slings

    5. Sound levels given at 75% prime power load 50 Hz at 7m

    6. Data at 100% load

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    V7 /

    12

    .16 /

    EN

    ER

    GYS

    T

    XQP150 EUIIIa XQ275 EUIIIaXQP100 EUIIIa XQP275 EUIIIa

    Prime

    50

    400V / 230V

    100

    80

    144

    200

    410

    20.3

    20

    2270 x 1120 x 1846

    2027

    2456

    77.8

    Prime

    50

    400V / 230V

    275

    220

    398

    630

    717

    48.1

    15

    4065 x 1400 x 2124

    3880

    4518

    66.4

    TECHNICAL INFORMATION

    https://www.energyst.com/news/power-generators-75-275-kva/https://www.energyst.com/uk/

  • POWER GENERATORS 365 - 500 KVA

    TECHNICAL INFORMATION

    Caterpillar is the largest producer of medium and high speed diesel engines, and its generators are known worldwide for their safety and reliability. We have temporary generator rental solutions ranging from a simple power set to multi-megawatt installations. It is heavy-duty equipment with low noise and – alongside base load supply – easy to ramp up and down with soft loading and unloading for peaking power.

    Our canopied containers are sound insulated, with super-silent models for extra-sensitive environments. The XQE line provides industry leading fuel effi ciency (up to 20% higher) and excellent performance. Ancillaries ensure your power supply meets the

    highest safety standards, from HV and LV cables and Powerlock.

    Energyst’s fuel-effi cient and low-emission CAT diesel generator solutions:• Form modular systems from 75 to 2000 kVA and above• Produce low emissions, meeting or exceeding local and

    national standards• Use DEIF generator controls, with 24/7 remote monitoring

    and fully automatic synchronisation between the generators or with the grid for peak shaving

    • Come with a standard internal, fully bunded environmentally safe double-walled diesel tank

    1. Performance data quoted in accordance with ISO 8528-1 2. Amps 50Hz at 400V 3. Fuel consumption measured at 75% load | fuel density is 850 G/L 4. Includes oil and coolant, excludes slings 5. Sound levels given at 75% prime power load 50 Hz at 7m

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    TECHNICAL INFORMATION

    WE’D LIKE TO HEAR FROM YOU

    CALL US: 00800 3637 4978EMAIL US: [email protected]

    If you would like to talk to us, request a rental or have a question there are two ways to contact us.

    Model XQ365E XQ455E XQ500 EU3 XQ600E

    Rating - Prime Prime Prime Prime

    Frequency Hz 50 50 50 50

    Voltage range V 400V / 230V 400V / 230V 400V / 230V 400V / 230V

    Power capacity1 kVA 365 455 500 600

    kW 292 364 400 480

    Output2 A 527 657 722 866

    Breaker 4P A 630 800 800 1600

    Fuel tank ltr 1098 1098 1020 1750

    Fuel consumption3 l/hr 56.3 65.6 82 104.3

    Running time hr 20 17 12 17

    Dimensions [LxWxH] mm 5050 x 1800 x 2300 5050 x 1800 x 2300 5325 x 2020 x 2505 6058 x 2438 x 2591

    Weight4 without fuel kg 8000 8300 6528 14110

    Weight4 with fuel kg 8940 9230 7395 15600

    Sound level5 dBA 61.2 59.3 68.5 64.5

    1. Performance data quoted in accordance with ISO 8528-1

    2. Amps 50Hz at 400V

    3. Fuel consumption measured at 75% load | fuel density is 850 G/L

    4. Includes oil and coolant, excludes slings

    5. Sound levels given at 75% prime power load 50 Hz at 7m

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    POWER GENERATORS 365 - 600 KVA

    Our heat pump rental solutions are stand-alone, closed packaged systems. They can supply hot and cold water that is transported through flexible high-pressure hoses to distribution devices.

    All our units have a standard design to make assembly, disassembly, installation and maintenance quick and easy. They are easy to transport with a forklift or a crane. They of course come complete with all the ancillaries and fittings you’ll need – like electric cables and water hoses.

    STAND-ALONE & EFFICIENT HEAT PUMP RENTAL

    ENERGYST HEAT PUMPSSPECIFICATION

    HEAT PUMPS 100-300 KW

    INSTANT GENERATOR RENTAL – FROM A FEW KW UP TO MULTI MEGAWATTS

    TECHNICAL INFORMATION

    WE’D LIKE TO HEAR FROM YOU

    CALL US: 00800 3637 4978EMAIL US: [email protected]

    If you would like to talk to us, request a rental or have a question there are two ways to contact us.

    Model XQP500 EUIIIA XQ500 EUIIIA XQ600E

    Rating - Prime Prime Prime

    Frequency Hz 50 50 50

    Voltage range V 400V / 230V 400V / 230V 400V / 230V

    Power capacity1 kVA 500 500 600

    kW 400 400 480

    Output2 A 722 722 866

    Breaker 4P A 800 800 1600

    Fuel tank ltr 965 1020 1750

    Fuel consumption3 l/hr 86.8 82 104.3

    Running time hr 11 12 17

    Dimensions [LxWxH] mm 5103 x 1954 x 2292 5325 x 2020 x 2505 6058 x 2438 x 2591

    Weight4 without fuel kg 5977 6528 14110

    Weight4 with fuel kg 6879 7395 15600

    Sound level5 dBA 67 68.5 64.5

    1. Performance data quoted in accordance with ISO 8528-1

    2. Amps 50Hz at 400V

    3. Fuel consumption measured at 75% load | fuel density is 850 G/L

    4. Includes oil and coolant, excludes slings

    5. Sound levels given at 75% prime power load 50 Hz at 7m

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    POWER GENERATORS 500 - 600 KVA

    V5 /

    12.1

    6 / E

    NER

    GYS

    T

    POWER GENERATORS 365 - 500 KVA

    TECHNICAL INFORMATION

    Caterpillar is the largest producer of medium and high speed diesel engines, and its generators are known worldwide for their safety and reliability. We have temporary generator rental solutions ranging from a simple power set to multi-megawatt installations. It is heavy-duty equipment with low noise and – alongside base load supply – easy to ramp up and down with soft loading and unloading for peaking power.

    Our canopied containers are sound insulated, with super-silent models for extra-sensitive environments. The XQE line provides industry leading fuel effi ciency (up to 20% higher) and excellent performance. Ancillaries ensure your power supply meets the

    highest safety standards, from HV and LV cables and Powerlock.

    Energyst’s fuel-effi cient and low-emission CAT diesel generator solutions:• Form modular systems from 75 to 2000 kVA and above• Produce low emissions, meeting or exceeding local and

    national standards• Use DEIF generator controls, with 24/7 remote monitoring

    and fully automatic synchronisation between the generators or with the grid for peak shaving

    • Come with a standard internal, fully bunded environmentally safe double-walled diesel tank

    1. Performance data quoted in accordance with ISO 8528-1 2. Amps 50Hz at 400V 3. Fuel consumption measured at 75% load | fuel density is 850 G/L 4. Includes oil and coolant, excludes slings 5. Sound levels given at 75% prime power load 50 Hz at 7m

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    TECHNICAL INFORMATION

    WE’D LIKE TO HEAR FROM YOU

    CALL US: 00800 3637 4978EMAIL US: [email protected]

    If you would like to talk to us, request a rental or have a question there are two ways to contact us.

    Model XQ365E XQ455E XQ500 EU3 XQ600E

    Rating - Prime Prime Prime Prime

    Frequency Hz 50 50 50 50

    Voltage range V 400V / 230V 400V / 230V 400V / 230V 400V / 230V

    Power capacity1 kVA 365 455 500 600

    kW 292 364 400 480

    Output2 A 527 657 722 866

    Breaker 4P A 630 800 800 1600

    Fuel tank ltr 1098 1098 1020 1750

    Fuel consumption3 l/hr 56.3 65.6 82 104.3

    Running time hr 20 17 12 17

    Dimensions [LxWxH] mm 5050 x 1800 x 2300 5050 x 1800 x 2300 5325 x 2020 x 2505 6058 x 2438 x 2591

    Weight4 without fuel kg 8000 8300 6528 14110

    Weight4 with fuel kg 8940 9230 7395 15600

    Sound level5 dBA 61.2 59.3 68.5 64.5

    1. Performance data quoted in accordance with ISO 8528-1

    2. Amps 50Hz at 400V

    3. Fuel consumption measured at 75% load | fuel density is 850 G/L

    4. Includes oil and coolant, excludes slings

    5. Sound levels given at 75% prime power load 50 Hz at 7m

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    POWER GENERATORS 365 - 600 KVA

    Our heat pump rental solutions are stand-alone, closed packaged systems. They can supply hot and cold water that is transported through flexible high-pressure hoses to distribution devices.

    All our units have a standard design to make assembly, disassembly, installation and maintenance quick and easy. They are easy to transport with a forklift or a crane. They of course come complete with all the ancillaries and fittings you’ll need – like electric cables and water hoses.

    STAND-ALONE & EFFICIENT HEAT PUMP RENTAL

    ENERGYST HEAT PUMPSSPECIFICATION

    HEAT PUMPS 100-300 KW

    INSTANT GENERATOR RENTAL – FROM A FEW KW UP TO MULTI MEGAWATTS

    TECHNICAL INFORMATION

    WE’D LIKE TO HEAR FROM YOU

    CALL US: 00800 3637 4978EMAIL US: [email protected]

    If you would like to talk to us, request a rental or have a question there are two ways to contact us.

    Model XQP500 EUIIIA XQ500 EUIIIA XQ600E

    Rating - Prime Prime Prime

    Frequency Hz 50 50 50

    Voltage range V 400V / 230V 400V / 230V 400V / 230V

    Power capacity1 kVA 500 500 600

    kW 400 400 480

    Output2 A 722 722 866

    Breaker 4P A 800 800 1600

    Fuel tank ltr 965 1020 1750

    Fuel consumption3 l/hr 86.8 82 104.3

    Running time hr 11 12 17

    Dimensions [LxWxH] mm 5103 x 1954 x 2292 5325 x 2020 x 2505 6058 x 2438 x 2591

    Weight4 without fuel kg 5977 6528 14110

    Weight4 with fuel kg 6879 7395 15600

    Sound level5 dBA 67 68.5 64.5

    1. Performance data quoted in accordance with ISO 8528-1

    2. Amps 50Hz at 400V

    3. Fuel consumption measured at 75% load | fuel density is 850 G/L

    4. Includes oil and coolant, excludes slings

    5. Sound levels given at 75% prime power load 50 Hz at 7m

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    POWER GENERATORS 500 - 600 KVA

    V5 /

    12.1

    6 / E

    NER

    GYS

    T

    POWER GENERATORS 500 KVA

    TECHNICAL INFORMATION

    WE’D LIKE TO HEAR FROM YOU

    CALL US: 00800 3637 4978EMAIL US: [email protected]

    If you would like to talk to us, request a rental or have a question there are two ways to contact us.

    Model

    Rating - Prime Prime

    Frequency Hz 50 50

    Voltage range V 400V / 230V 400V / 230V

    Power capacity1 kVA 500 500

    kW 400 400

    Output2 A 722 722

    Breaker 4P A 800 800

    Fuel tank ltr 965 1020

    Fuel consumption3 l/hr 86.8 73.1

    Running time hr 11 14

    Dimensions [LxWxH] mm 5103 x 1954 x 2292 5325 x 2020 x 2505

    Weight4 without fuel kg 5977 6528

    Weight4 with fuel kg 6879 7468

    Sound level5 dBA 67 68.5

    POWER GENERATORS 500 KVA

    V5 /

    12.1

    6 / E

    NER

    GYST

    1 Performance data quoted in accordance with ISO 8528-1

    2 Amps 50Hz at 400V, 60Hz at 480V

    3 Fuel consumption measured at 75% load. Fuel density is 850 G/L

    4 includes oil and coolant, excludes slings.

    5 Sound levels given at 75% prime power load 50 Hz at 7m, Sound data 60 hz is estimated 2 dBa more then 50 Hz based on bare engine data.

    6 Design data

    7 Data at 100% load

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    60Hz versions available on request

    The majority of our rental solutions is equipped with remote monitoring.

    XQ500EXQ500 EUIIIaXQP500 EUIIIa

    Prime

    50

    400V / 230V

    500

    400

    722

    800

    950

    76

    13

    5235 x 1758 x 2546

    6225

    7033

    66.8

    TECHNICAL INFORMATION

    60 Hz versions available on request.

    The majority of our generators is equipped with remote monitoring.

    1. Performance data quoted in accordance with ISO 8528-1 2. Amps 50Hz at 400V, 60Hz at 480V 3. Fuel consumption measured at 75% load. Fuel density is 850 G/L 4. Includes oil and coolant, excludes slings.

    5. Sound levels given at 75% prime power load 50 Hz at 7m, Sound data 60 Hz is estimated 2 dBa more than 50 Hz based on bare engine data.

    6. Design data 7. Data at 100% load

    https://www.energyst.com/news/power-generators-365-600-kva/https://www.energyst.com/uk/

  • TECHNICAL INFORMATION

    Caterpillar is the largest producer of medium and high speed diesel engines, and its generators are known worldwide for their safety and reliability. We have temporary generator rental solutions ranging from a simple power set to multi-megawatt installations. It is heavy-duty equipment with low noise and – alongside base load supply – easy to ramp up and down with soft loading and unloading for peaking power.

    Our generators are housed in robust cast-iron 20-foot (diesel only) or 40- foot (diesel and gas) CSC plated ISO containers that are easy to transport by road, sea or air. They are simple to assemble, operate and maintain. The XQE line provides industry leading fuel effi ciency (up to 20% higher) and excellent performance. Ancillaries ensure your power supply meets the highest safety standards, from

    HV and LV cables and Powerlock connectors to fuel tanks, and 32- to 3200-A distribution boxes.

    Energyst’s fuel-effi cient and low-emission CAT diesel generator solutions:• Form modular systems from 75 to 2000 kVA and above• Produce low emissions, meeting or exceeding local and

    national standards• Use DEIF generator controls, with 24/7 remote monitoring

    and fully automatic synchronisation between the generators or with the grid for peak shaving

    • Come with a standard internal, fully bunded environmentally safe double-walled diesel tanksafe double-walled diesel tank

    1. Performance data quoted in accordance with ISO 8528-1 2. Amps 50Hz at 400V 3. Fuel consumption measured at 75% load | fuel density is 850 G/L4. Includes oil and coolant, excludes slings 5. Sound levels given at 75% prime power load 50 Hz at 7m

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    TECHNICAL INFORMATION

    WE’D LIKE TO HEAR FROM YOU

    CALL US: 00800 3637 4978EMAIL US: [email protected]

    If you would like to talk to us, request a rental or have a question there are two ways to contact us.

    Model XQ810E XQ810E Mera XQ1000E XQ1500E XQ1500 XQ2000E

    Rating - Prime Prime Prime Prime Prime Prime

    Frequency Hz 50 50 50 50 50 50

    Voltage range V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V

    Power capacity1 kVA 810 810 1000 1500 1500 2000

    kW 648 648 800 1200 1200 1600

    Output2 A 1170 1170 1445 2167 2167 2890

    Breaker 4P A 1600 1600 1600 2500 2500 3200

    Fuel tank ltr 1750 1750 1200 3500 400 3500

    Fuel consumption3 l/hr 126.1 126.1 156.8 225.2 231 306.3

    Running time hr 14 14 8 16 2 11

    Dimensions [LxWxH] mm 6058 x 2438 x 2591 5900 x 2238 x 2553 6058 x 2438 x 2591 12192 x 2438 x 2591 6058 x 2438 x 2896 12192 x 2438 x 2591

    Weight4 without fuel kg 15410 10000 15570 26600 20000 28400

    Weight4 with fuel kg 16910 11500 16570 29600 20400 31400

    Sound level5 dBA 68 727 69,7 70,5 81 67,2

    1. Performance data quoted in accordance with ISO 8528-1

    2. Amps 50Hz at 400V

    3. Fuel consumption measured at 75% load | fuel density is 850 G/L

    4. Includes oil and coolant, excludes slings

    5. Sound levels given at 75% prime power load 50 Hz at 7m

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    POWER GENERATORS 810 - 2000 KVA

    Our heat pump rental solutions are stand-alone, closed packaged systems. They can supply hot and cold water that is transported through flexible high-pressure hoses to distribution devices.

    All our units have a standard design to make assembly, disassembly, installation and maintenance quick and easy. They are easy to transport with a forklift or a crane. They of course come complete with all the ancillaries and fittings you’ll need – like electric cables and water hoses.

    STAND-ALONE & EFFICIENT HEAT PUMP RENTAL

    ENERGYST HEAT PUMPSSPECIFICATION

    HEAT PUMPS 100-300 KW

    INSTANT GENERATOR RENTAL – FROM A FEW KW UP TO MULTI MEGAWATTS

    TECHNICAL INFORMATION

    Caterpillar is the largest producer of medium and high speed diesel engines, and its generators are known worldwide for their safety and reliability. We have temporary generator rental solutions ranging from a simple power set to multi-megawatt installations. It is heavy-duty equipment with low noise and – alongside base load supply – easy to ramp up and down with soft loading and unloading for peaking power.

    Our generators are housed in robust cast-iron 20-foot (diesel only) or 40- foot (diesel and gas) CSC plated ISO containers that are easy to transport by road, sea or air. They are simple to assemble, operate and maintain. The XQE line provides industry leading fuel effi ciency (up to 20% higher) and excellent performance. Ancillaries ensure your power supply meets the highest safety standards, from

    HV and LV cables and Powerlock connectors to fuel tanks, and 32- to 3200-A distribution boxes.

    Energyst’s fuel-effi cient and low-emission CAT diesel generator solutions:• Form modular systems from 75 to 2000 kVA and above• Produce low emissions, meeting or exceeding local and

    national standards• Use DEIF generator controls, with 24/7 remote monitoring

    and fully automatic synchronisation between the generators or with the grid for peak shaving

    • Come with a standard internal, fully bunded environmentally safe double-walled diesel tanksafe double-walled diesel tank

    1. Performance data quoted in accordance with ISO 8528-1 2. Amps 50Hz at 400V 3. Fuel consumption measured at 75% load | fuel density is 850 G/L4. Includes oil and coolant, excludes slings 5. Sound levels given at 75% prime power load 50 Hz at 7m

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    TECHNICAL INFORMATION

    WE’D LIKE TO HEAR FROM YOU

    CALL US: 00800 3637 4978EMAIL US: [email protected]

    If you would like to talk to us, request a rental or have a question there are two ways to contact us.

    Model XQ810E XQ810E Mera XQ1000E XQ1500E XQ1500 XQ2000E

    Rating - Prime Prime Prime Prime Prime Prime

    Frequency Hz 50 50 50 50 50 50

    Voltage range V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V

    Power capacity1 kVA 810 810 1000 1500 1500 2000

    kW 648 648 800 1200 1200 1600

    Output2 A 1170 1170 1445 2167 2167 2890

    Breaker 4P A 1600 1600 1600 2500 2500 3200

    Fuel tank ltr 1750 1750 1200 3500 400 3500

    Fuel consumption3 l/hr 126.1 126.1 156.8 225.2 231 306.3

    Running time hr 14 14 8 16 2 11

    Dimensions [LxWxH] mm 6058 x 2438 x 2591 5900 x 2238 x 2553 6058 x 2438 x 2591 12192 x 2438 x 2591 6058 x 2438 x 2896 12192 x 2438 x 2591

    Weight4 without fuel kg 15410 10000 15570 26600 20000 28400

    Weight4 with fuel kg 16910 11500 16570 29600 20400 31400

    Sound level5 dBA 68 727 69,7 70,5 81 67,2

    1. Performance data quoted in accordance with ISO 8528-1

    2. Amps 50Hz at 400V

    3. Fuel consumption measured at 75% load | fuel density is 850 G/L

    4. Includes oil and coolant, excludes slings

    5. Sound levels given at 75% prime power load 50 Hz at 7m

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    POWER GENERATORS 810 - 2000 KVA

    Our heat pump rental solutions are stand-alone, closed packaged systems. They can supply hot and cold water that is transported through flexible high-pressure hoses to distribution devices.

    All our units have a standard design to make assembly, disassembly, installation and maintenance quick and easy. They are easy to transport with a forklift or a crane. They of course come complete with all the ancillaries and fittings you’ll need – like electric cables and water hoses.

    STAND-ALONE & EFFICIENT HEAT PUMP RENTAL

    ENERGYST HEAT PUMPSSPECIFICATION

    HEAT PUMPS 100-300 KW

    INSTANT GENERATOR RENTAL – FROM A FEW KW UP TO MULTI MEGAWATTS

    POWER GENERATORS 1000 - 2000 KVA

    TECHNICAL INFORMATION

    WE’D LIKE TO HEAR FROM YOU

    CALL US: 00800 3637 4978EMAIL US: [email protected]

    If you would like to talk to us, request a rental or have a question there are two ways to contact us.

    Model XQ810E XQ810E Mera XQ1000E XQ1500E PM1360 XQ2000E

    Rating - Prime Prime Prime Prime Prime Prime

    Frequency Hz 50 50 50 50 50 50

    Voltage range V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V

    Power capacity1 kVA 810 810 1000 1500 1500 2000

    kW 648 648 800 1200 1200 1600

    Output2 A 1170 1170 1445 2167 2167 2890

    Breaker 4P A 1600 1600 1600 2500 2500 3200

    Fuel tank ltr 1750 1750 1200 3500 400 3500

    Fuel consumption3 l/hr 126.1 126.1 184 225.2 231 306.3

    Running time hr 14 14 8 16 2 11

    Dimensions [LxWxH] mm 6058 x 2438 x 2591 5900 x 2238 x 2553 6058 x 2438 x 2591 12192 x 2438 x 2591 6058 x 2438 x 2896 12192 x 2438 x 2591

    Weight4 without fuel kg 15410 10000 15570 26600 20000 28400

    Weight4 with fuel kg 16910 11500 16570 29600 20400 31400

    Sound level5 dBA 68 727 69,7 70,5 81 67,2

    1. Performance data quoted in accordance with ISO 8528-1

    2. Amps 50Hz at 400V

    3. Fuel consumption measured at 75% load | fuel density is 850 G/L

    4. Includes oil and coolant, excludes slings

    5. Sound levels given at 75% prime power load 50 Hz at 7m

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    POWER GENERATORS 1000 - 2000 KVA

    TECHNICAL INFORMATION

    WE’D LIKE TO HEAR FROM YOU

    CALL US: 00800 3637 4978EMAIL US: [email protected]

    If you would like to talk to us, request a rental or have a question there are two ways to contact us.

    Model XQ810E XQ810E Mera XQ1000E XQ1500E PM1360 XQ2000E

    Rating - Prime Prime Prime Prime Prime Prime

    Frequency Hz 50 50 50 50 50 50

    Voltage range V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V

    Power capacity1 kVA 810 810 1000 1500 1500 2000

    kW 648 648 800 1200 1200 1600

    Output2 A 1170 1170 1445 2167 2167 2890

    Breaker 4P A 1600 1600 1600 2500 2500 3200

    Fuel tank ltr 1750 1750 1200 3500 400 3500

    Fuel consumption3 l/hr 126.1 126.1 184 225.2 231 306.3

    Running time hr 14 14 8 16 2 11

    Dimensions [LxWxH] mm 6058 x 2438 x 2591 5900 x 2238 x 2553 6058 x 2438 x 2591 12192 x 2438 x 2591 6058 x 2438 x 2896 12192 x 2438 x 2591

    Weight4 without fuel kg 15410 10000 15570 26600 20000 28400

    Weight4 with fuel kg 16910 11500 16570 29600 20400 31400

    Sound level5 dBA 68 727 69,7 70,5 81 67,2

    1. Performance data quoted in accordance with ISO 8528-1

    2. Amps 50Hz at 400V

    3. Fuel consumption measured at 75% load | fuel density is 850 G/L

    4. Includes oil and coolant, excludes slings

    5. Sound levels given at 75% prime power load 50 Hz at 7m

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    POWER GENERATORS 1000 - 2000 KVA

    TECHNICAL INFORMATION

    WE’D LIKE TO HEAR FROM YOU

    CALL US: 00800 3637 4978EMAIL US: [email protected]

    If you would like to talk to us, request a rental or have a question there are two ways to contact us.

    Model XQ810E XQ810E Mera XQ1000E XQ1500E PM1360 XQ2000E

    Rating - Prime Prime Prime Prime Prime Prime

    Frequency Hz 50 50 50 50 50 50

    Voltage range V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V

    Power capacity1 kVA 810 810 1000 1500 1500 2000

    kW 648 648 800 1200 1200 1600

    Output2 A 1170 1170 1445 2167 2167 2890

    Breaker 4P A 1600 1600 1600 2500 2500 3200

    Fuel tank ltr 1750 1750 1200 3500 400 3500

    Fuel consumption3 l/hr 126.1 126.1 184 225.2 231 306.3

    Running time hr 14 14 8 16 2 11

    Dimensions [LxWxH] mm 6058 x 2438 x 2591 5900 x 2238 x 2553 6058 x 2438 x 2591 12192 x 2438 x 2591 6058 x 2438 x 2896 12192 x 2438 x 2591

    Weight4 without fuel kg 15410 10000 15570 26600 20000 28400

    Weight4 with fuel kg 16910 11500 16570 29600 20400 31400

    Sound level5 dBA 68 727 69,7 70,5 81 67,2

    1. Performance data quoted in accordance with ISO 8528-1

    2. Amps 50Hz at 400V

    3. Fuel consumption measured at 75% load | fuel density is 850 G/L

    4. Includes oil and coolant, excludes slings

    5. Sound levels given at 75% prime power load 50 Hz at 7m

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    POWER GENERATORS 1000 - 2000 KVA

    TECHNICAL INFORMATION

    WE’D LIKE TO HEAR FROM YOU

    CALL US: 00800 3637 4978EMAIL US: [email protected]

    If you would like to talk to us, request a rental or have a question there are two ways to contact us.

    Model XQ810E XQ810E Mera XQ1000E XQ1500E PM1360 XQ2000E

    Rating - Prime Prime Prime Prime Prime Prime

    Frequency Hz 50 50 50 50 50 50

    Voltage range V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V

    Power capacity1 kVA 810 810 1000 1500 1500 2000

    kW 648 648 800 1200 1200 1600

    Output2 A 1170 1170 1445 2167 2167 2890

    Breaker 4P A 1600 1600 1600 2500 2500 3200

    Fuel tank ltr 1750 1750 1200 3500 400 3500

    Fuel consumption3 l/hr 126.1 126.1 184 225.2 231 306.3

    Running time hr 14 14 8 16 2 11

    Dimensions [LxWxH] mm 6058 x 2438 x 2591 5900 x 2238 x 2553 6058 x 2438 x 2591 12192 x 2438 x 2591 6058 x 2438 x 2896 12192 x 2438 x 2591

    Weight4 without fuel kg 15410 10000 15570 26600 20000 28400

    Weight4 with fuel kg 16910 11500 16570 29600 20400 31400

    Sound level5 dBA 68 727 69,7 70,5 81 67,2

    1. Performance data quoted in accordance with ISO 8528-1

    2. Amps 50Hz at 400V

    3. Fuel consumption measured at 75% load | fuel density is 850 G/L

    4. Includes oil and coolant, excludes slings

    5. Sound levels given at 75% prime power load 50 Hz at 7m

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    POWER GENERATORS 1000 - 2000 KVA

    1 Performance data quoted in accordance with ISO 8528-1

    2 Amps 50Hz at 400V, 60Hz at 480V

    3 Fuel consumption measured at 75% load. Fuel density is 850 G/L

    4 includes oil and coolant, excludes slings

    5 Sound levels given at 75% prime power load 50 Hz at 7m, Sound data 60 hz is estimated 2 dBa more then 50 Hz based on bare engine data

    6 Design data

    7 Data at 100% load

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    60Hz versions available on request

    The majority of our rental solutions is equipped with remote monitoring.

    1. Performance data quoted in accordance with ISO 8528-1

    2. Amps 50Hz at 400V, 60Hz at 480V 3. Fuel consumption measured at 75%

    load. Fuel density is 850 G/L 4. Includes oil and coolant, excludes

    slings. 5. Sound levels given at 75% prime power

    load 50 Hz at 7m, Sound data 60 Hz is estimated 2 dBa more than 50 Hz based on bare engine data.

    6. Design data 7. Data at 100% load

    60 Hz versions available on request.

    The majority of our generators is equipped with remote monitoring.

    https://www.energyst.com/news/power-generators-810-2000-kva/https://www.energyst.com/uk/

  • WE’D LIKE TO HEAR FROM YOU

    CALL US: 00800 3637 4978EMAIL US: [email protected]

    If you would like to talk to us, request a rental or have a question there are two ways to contact us.

    TECHNICAL INFORMATION

    1. Performance data quoted in accordance with ISO 8528-1

    2. Amps 50HZ at 400V | 60Hz at 480V

    3. Fuel consumption measured at 75% load | Fuel density is 850 G/L

    4. Includes oil and coolant, excludes slings

    5. Sound levels given at 75% prime power load 50Hz at 7m | Sound data 60Hz is estimated 2 dBA more than 50Hz based on bare engine data

    6. Design data

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    Model

    Rating

    Frequency Hz

    Voltage range V

    Power capacity1 kVA

    kW

    Output2 A

    Breaker 4P A

    Fuel tank L

    Fuel consumption3 l/hr

    Running time hr

    Dimensions [LxWxH] mm

    Weight4 without fuel kg

    Weight4 with fuel kg

    Sound level5 dBA

    XQ1250E

    Prime Standby Prime Standby

    50 60

    400V / 230V 480V / 277V

    1000 1100 1137 1250

    800 880 910 1000

    1445 1589 1369 1505

    1600

    1190

    162 175 168 200

    7 7 7 6

    6058 x 2438 x 2590

    18140

    19152

    73.9 73.9 76.8 76.8

    OFFSHORE POWER GENERATORS NORSOK XQ1250E

    V1 /

    12.1

    6 / E

    NER

    GYS

    T

    TECHNICAL INFORMATION

    At Energyst we know that saving space is key in the offshore industry. That is why we put real energy into designing the most compact offshore generator available in the market.

    Energyst’s diesel driven generators are manufactured by Caterpillar and are housed in a custom designed offshore rental package comprising of a custom built DNV 2.7-1 certifi ed 20-ft ISO container. The package has been designed to provide fl exibility

    for all types of end user operation. The equipment packages are classifi ed NORSOK Z-015 for use in non-hazardous zone. The key safety features outlined within the XQ power modules are: fi re & gas detection and suppression, air shut off, spark arrestor, emergency stop and sea mist fi lter. Our offshore equipment range includes transformers and fuel tanks.

    1. Performance data quoted in accordance with ISO 8528-1 2. Amps 50Hz at 400V, 60Hz at 480V 3. Fuel consumption measured at 75% load | Fuel density is 850 G/L 4. Includes oil and coolant, excludes slings 5. Sound levels given at 75% prime power load 50Hz at 7m | Sound data 60Hz is estimated 2 dBA more than 50Hz based on bare engine data 6. Design data

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    Our heat pump rental solutions are stand-alone, closed packagedsystems. They can supply hot and cold water that is transported throughflexible high-pressure hoses to distribution devices.

    All our units have a standard design to make assembly, disassembly,installation and maintenance quick and easy. They are easy to transportwith a forklift or a crane. They of course come complete with all theancillaries and fittings you’ll need – like electric cables and water hoses.

    STAND-ALONE & EFFICIENT HEAT PUMP RENTAL

    ENERGYST HEAT PUMPSSPECIFICATION

    HEAT PUMPS 100-300 KW

    ENERGYST CAT RENTAL POWER IS BUILT ON THE LATEST OFFSHORE REQUIREMENTS TO MEET THE DEMANDS OF THE ENERGY SECTOR, ENSURING SAFE EQUIPMENT WITH A RELIABLE PARTNER TO SECURE YOUR PRODUCTION.

    OFFSHORE POWER GENERATOR NORSOK XQ1250E

    1. Performance data quoted in accordance with ISO 8528-1

    2. Amps 50Hz at 400V, 60Hz at 480V3. Fuel consumption measured at 75% load. Fuel density

    is 850 G/L 4. Includes oil and coolant, excludes slings.5. Sound levels given at 75% prime power load 50 Hz

    at 7m, Sound data 60 Hz is estimated 2 dBa more than 50 Hz based on bare engine data.

    6. Design data

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    The majority of our generators is equipped with remote monitoring.

    https://www.energyst.com/uk/news/offshore-power-generator-norsok-xq1250e/https://www.energyst.com/uk/

  • WE’D LIKE TO HEAR FROM YOU

    CALL US: 00800 3637 4978EMAIL US: [email protected]

    If you would like to talk to us, request a rental or have a question there are two ways to contact us.

    TECHNICAL INFORMATION

    1. Performance data quoted in accordance with ISO 8528-1

    2. Amps 50Hz at 400V | 60Hz at 480V

    3. Fuel consumption measured at 75% load | Fuel density is 850 G/L

    4. Includes oil and coolant, excludes slings

    5. Sound levels given at 75% prime power load 50Hz at 7m | Sound data 60Hz is estimated 2 dBA more than 50Hz based on bare engine data

    6. Design data

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    Model

    Rating

    Frequency Hz

    Voltage range V

    Power capacity1 kVA

    kW

    Output2 A

    Breaker 4P A

    Fuel tank L

    Fuel consumption3 l/hr

    Running time hr

    Dimensions [LxWxH] mm

    Weight4 without fuel kg

    Weight4 with fuel kg

    Sound level5 dBA

    Prime Standby Prime Standby

    50 60

    400V / 230V 480V / 277V

    1500 1650 1700 1870

    1200 1320 1360 1496

    2167 2384 2047 2251

    2500

    1650

    236 258 269 297

    7 6 6 6

    6058 x 2438 x 2896

    225005

    240005

    856

    OFFSHORE POWER GENERATORS NORSOK XQ1700

    TECHNICAL INFORMATION

    At Energyst we know that saving space is key in the offshore industry. That is why we put real energy into designing the most compact offshore generator available in the market.

    It’s the people at Energyst that make the difference. By listening to the market and transforming its demands into true innovations. On a global level Energyst is the fi rst rental company to introduce a 1700 kVA NORSOK approved generator that fi ts into a 20 foot container. Our latest innovation, designed together with our partner Caterpillar, saves you 50% of space.

    Energyst’s diesel driven generators are manufactured by Caterpillar and are housed in a custom designed offshore rental package comprising of a custom built DNV 2.7-1 certifi ed 20-ft ISO container. The package has been designed to provide fl exibility for all types of end user operation.

    The equipment packages are classifi ed NORSOK Z-015 for use in nonhazardous zone. The key safety features outlined within the XQ power modules are: fi re & gas detection and suppression, air shut off, spark arrestor, emergency stop and sea mist fi lter. Our offshore equipment range includes transformers and fuel tanks.

    1. Performance data quoted in accordance with ISO 8528-1 2. Amps 50Hz at 400V, 60Hz at 480V 3. Fuel consumption measured at 75% load | Fuel density is 850 G/L 4. Includes oil and coolant, excludes slings 5. Sound levels given at 75% prime power load 50Hz at 7m | Sound data 60Hz is estimated 2 dBA more than 50Hz based on bare engine data 6. Design data

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    Our heat pump rental solutions are stand-alone, closed packaged systems. They can supply hot and cold water that is transported through flexible high-pressure hoses to distribution devices.

    All our units have a standard design to make assembly, disassembly, installation and maintenance quick and easy. They are easy to transport with a forklift or a crane. They of course come complete with all the ancillaries and fittings you’ll need – like electric cables and water hoses.

    STAND-ALONE & EFFICIENT HEAT PUMP RENTAL

    ENERGYST HEAT PUMPSSPECIFICATION

    HEAT PUMPS 100-300 KW

    ENERGYST CAT RENTAL POWER IS BUILT ON THE LATEST OFFSHORE REQUIREMENTS TO MEET THE DEMANDS OF THE ENERGY SECTOR, ENSURING SAFE EQUIPMENT WITH A RELIABLE PARTNER TO SECURE YOUR PRODUCTION.

    OFFSHORE POWER GENERATOR NORSOK 1700

    1700

    1. Performance data quoted in accordance with ISO 8528-1

    2. Amps 50Hz at 400V, 60Hz at 480V 3. Fuel consumption measured at 75% load. Fuel density

    is 850 G/L 4. Includes oil and coolant, excludes slings. 5. Sound levels given at 75% prime power load 50 Hz

    at 7m, Sound data 60 Hz is estimated 2 dBa more than 50 Hz based on bare engine data.

    6. Design data

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    The majority of our generators is equipped with remote monitoring.

    https://www.energyst.com/uk/news/offshore-power-generators-norsok-xq1700/https://www.energyst.com/uk/

  • TECHNICAL INFORMATION

    WE’D LIKE TO HEAR FROM YOU

    CALL US: 00800 3637 4978EMAIL US: [email protected]

    If you would like to talk to us, request a rental or have a question there are two ways to contact us.

    1. Performance data quoted in accordance with ISO 8528-1

    2. Amps 50Hz at 400V | 60Hz at 480V

    3. Fuel consumption measured at 75% load | Fuel density is 850 G/L

    4. Includes oil and coolant | excludes slings

    5. Sound levels given at 75% prime power load 50Hz at 7m | Sound data 60Hz is estimated 2 dBA more than 50Hz based on bare engine data.

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    OFFSHORE POWER GENERATORS RIGSAFE

    Model

    Rating

    Frequency Hz

    Voltage Range V

    Power capacity1 kVA

    kW

    Output2 A

    Breaker 4P A

    Fuel tank L

    Fuel consumption3 l/hr

    Running time hr

    Dimensions [LxWxH] mm

    Weight4 without fuel kg

    Weight4 with fuel kg

    Sound level5 dBA

    XQ250E

    Prime Standby Prime Standby

    50 60

    400V / 230V 480V / 277V

    250 275 250 275

    200 220 200 220

    360 395 305 331

    400

    1200

    35,2 42,1 41,5 48,9

    34 29 29 25

    4600 x 1800 x 2616

    6210

    7410

    66,9 66,9 68,9 68,9

    XQ500E

    Prime Standby Prime Standby

    50 60

    400V / 230V 480V / 277V

    500 550 500 562,5

    400 440 400 440

    722 795 605 677

    800

    1250

    72,6 91,2 81,3 89,6

    17 14 15 14

    5400 x 2100 x 3130

    8875

    9683

    66,8 66,8 68,8 68,8

    V1 /

    12.1

    6 / E

    NER

    GYS

    T

    ENERGYST CAT RENTAL POWER IS BUILT ON THE LATEST OFFSHORE REQUIREMENTSTO MEET THE DEMANDS OF THE INDUSTRY.

    OFFSHORE POWER GENERATORS RIGSAFE

    ENERGYSTOFFSHORE POWER GENERATORS SPECIFICATION

    At Energyst we know that safety is a prerequisite in the offshore industry. That is why, together with our partner Caterpillar, we put real energy into designing the best offshore generators available in the market.

    Energyst’s diesel driven Rig Safe generators are manufactured by Caterpillar and are housed in a custom designed offshore rental package comprising of a canopied generator in a DNV 2.7-1 certified lifting frame. The package has been designed to provide flexibility for all types of end user operation. The equipment packages are classified for use in non-hazardous zone.

    The key safety features outlined within the XQ power modules are: air shut off, spark arrestor, emergency stop, stainless steel braided fuel lines, anti-static drive belts and ‘Yellow Alert’ rig ESD.

    Our offshore equipment range also includes transformers, fuel tanks and NORSOK generators.

    1 Chalwyn Valve

    2 Exhaust Spark Arrestor

    3 ESD Button

    4 Anti static drive belts

    5 Battery Isolation

    6 Yellow alert shutdown module

    7 DNV 2.7-1 Offshore lifting frame

    8 Generator earth bonded to DNV Frame

    9 Braided fuel hoses

    10 Front line spares kit

    11 Certification document pack

    OUTLINE TECHNICAL/SAFETY SPECIFICATION

    TECHNICAL INFORMATION

    OUTLINE TECHNICAL /SAFETY SPECIFICATION

    At Energyst we know that safety is a prerequisite in the offshore industry. That is why, together with our partner Caterpillar, we put real energy into designing the best offshore generators available in the market.

    Energyst’s diesel driven Rig Safe generators are manufactured by Caterpillar and are housed in a custom designed offshore rental package comprising of a canopied generator in a DNV 2.7-1 certifi ed lifting frame. The package has been designed to provide fl exibility for all types

    of end user operation. The equipment packages are classifi ed for use in non-hazardous zone.

    The key safety features outlined within the XQ power modules are: air shut off, spark arrestor, emergency stop, stainless steel braided fuel lines, anti-static drive belts and ‘Yellow Alert’ rig ESD.

    Our offshore equipment range also includes transformers, fuel tanks and NORSOK generators.

    Our heat pump rental solutions are stand-alone, closed packaged systems. They can supply hot and cold water that is transported through flexible high-pressure hoses to distribution devices.

    All our units have a standard design to make assembly, disassembly, installation and maintenance quick and easy. They are easy to transport with a forklift or a crane. They of course come complete with all the ancillaries and fittings you’ll need – like electric cables and water hoses.

    STAND-ALONE & EFFICIENT HEAT PUMP RENTAL

    ENERGYST HEAT PUMPSSPECIFICATION

    HEAT PUMPS 100-300 KW

    ENERGYST CAT RENTAL POWER IS BUILT ON THE LATEST OFFSHOREREQUIREMENTS TO MEET THE DEMANDS OF THE INDUSTRY.

    1. Performance data quoted in accordance with ISO 8528-1 2. Amps 50Hz at 400V | 60Hz at 480V 3. Fuel consumption measured at 75% load | Fuel density is 850 G/L 4. Includes oil and coolant, excludes slings 5. Sound levels given at 75% prime power load 50Hz at 7m | Sound data 60Hz is estimated 2 dBA more than 50Hz based on bare engine data

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    TECHNICAL INFORMATION

    WE’D LIKE TO HEAR FROM YOU

    CALL US: 00800 3637 4978EMAIL US: [email protected]

    If you would like to talk to us, request a rental or have a question there are two ways to contact us.

    1. Performance data quoted in accordance with ISO 8528-1

    2. Amps 50Hz at 400V | 60Hz at 480V

    3. Fuel consumption measured at 75% load | Fuel density is 850 G/L

    4. Includes oil and coolant | excludes slings

    5. Sound levels given at 75% prime power load 50Hz at 7m | Sound data 60Hz is estimated 2 dBA more than 50Hz based on bare engine data.

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    OFFSHORE POWER GENERATORS RIGSAFE

    Model

    Rating

    Frequency Hz

    Voltage Range V

    Power capacity1 kVA

    kW

    Output2 A

    Breaker 4P A

    Fuel tank L

    Fuel consumption3 l/hr

    Running time hr

    Dimensions [LxWxH] mm

    Weight4 without fuel kg

    Weight4 with fuel kg

    Sound level5 dBA

    XQ250E

    Prime Standby Prime Standby

    50 60

    400V / 230V 480V / 277V

    250 275 250 275

    200 220 200 220

    360 395 305 331

    400

    1200

    35,2 42,1 41,5 48,9

    34 29 29 25

    4600 x 1800 x 2616

    6210

    7410

    66,9 66,9 68,9 68,9

    XQ500E

    Prime Standby Prime Standby

    50 60

    400V / 230V 480V / 277V

    500 550 500 562,5

    400 440 400 440

    722 795 605 677

    800

    1250

    72,6 91,2 81,3 89,6

    17 14 15 14

    5400 x 2100 x 3130

    8875

    9683

    66,8 66,8 68,8 68,8

    V1 /

    12.1

    6 / E

    NER

    GYS

    T

    ENERGYST CAT RENTAL POWER IS BUILT ON THE LATEST OFFSHORE REQUIREMENTSTO MEET THE DEMANDS OF THE INDUSTRY.

    OFFSHORE POWER GENERATORS RIGSAFE

    ENERGYSTOFFSHORE POWER GENERATORS SPECIFICATION

    At Energyst we know that safety is a prerequisite in the offshore industry. That is why, together with our partner Caterpillar, we put real energy into designing the best offshore generators available in the market.

    Energyst’s diesel driven Rig Safe generators are manufactured by Caterpillar and are housed in a custom designed offshore rental package comprising of a canopied generator in a DNV 2.7-1 certified lifting frame. The package has been designed to provide flexibility for all types of end user operation. The equipment packages are classified for use in non-hazardous zone.

    The key safety features outlined within the XQ power modules are: air shut off, spark arrestor, emergency stop, stainless steel braided fuel lines, anti-static drive belts and ‘Yellow Alert’ rig ESD.

    Our offshore equipment range also includes transformers, fuel tanks and NORSOK generators.

    1 Chalwyn Valve

    2 Exhaust Spark Arrestor

    3 ESD Button

    4 Anti static drive belts

    5 Battery Isolation

    6 Yellow alert shutdown module

    7 DNV 2.7-1 Offshore lifting frame

    8 Generator earth bonded to DNV Frame

    9 Braided fuel hoses

    10 Front line spares kit

    11 Certification document pack

    OUTLINE TECHNICAL/SAFETY SPECIFICATION

    TECHNICAL INFORMATION

    OUTLINE TECHNICAL /SAFETY SPECIFICATION

    At Energyst we know that safety is a prerequisite in the offshore industry. That is why, together with our partner Caterpillar, we put real energy into designing the best offshore generators available in the market.

    Energyst’s diesel driven Rig Safe generators are manufactured by Caterpillar and are housed in a custom designed offshore rental package comprising of a canopied generator in a DNV 2.7-1 certifi ed lifting frame. The package has been designed to provide fl exibility for all types

    of end user operation. The equipment packages are classifi ed for use in non-hazardous zone.

    The key safety features outlined within the XQ power modules are: air shut off, spark arrestor, emergency stop, stainless steel braided fuel lines, anti-static drive belts and ‘Yellow Alert’ rig ESD.

    Our offshore equipment range also includes transformers, fuel tanks and NORSOK generators.

    Our heat pump rental solutions are stand-alone, closed packaged systems. They can supply hot and cold water that is transported through flexible high-pressure hoses to distribution devices.

    All our units have a standard design to make assembly, disassembly, installation and maintenance quick and easy. They are easy to transport with a forklift or a crane. They of course come complete with all the ancillaries and fittings you’ll need – like electric cables and water hoses.

    STAND-ALONE & EFFICIENT HEAT PUMP RENTAL

    ENERGYST HEAT PUMPSSPECIFICATION

    HEAT PUMPS 100-300 KW

    ENERGYST CAT RENTAL POWER IS BUILT ON THE LATEST OFFSHOREREQUIREMENTS TO MEET THE DEMANDS OF THE INDUSTRY.

    1. Performance data quoted in accordance with ISO 8528-1 2. Amps 50Hz at 400V | 60Hz at 480V 3. Fuel consumption measured at 75% load | Fuel density is 850 G/L 4. Includes oil and coolant, excludes slings 5. Sound levels given at 75% prime power load 50Hz at 7m | Sound data 60Hz is estimated 2 dBA more than 50Hz based on bare engine data

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    TECHNICAL INFORMATION

    WE’D LIKE TO HEAR FROM YOU

    CALL US: 00800 3637 4978EMAIL US: [email protected]

    If you would like to talk to us, request a rental or have a question there are two ways to contact us.

    1. Performance data quoted in accordance with ISO 8528-1

    2. Amps 50Hz at 400V | 60Hz at 480V

    3. Fuel consumption measured at 75% load | Fuel density is 850 G/L

    4. Includes oil and coolant | excludes slings

    5. Sound levels given at 75% prime power load 50Hz at 7m | Sound data 60Hz is estimated 2 dBA more than 50Hz based on bare engine data.

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    OFFSHORE POWER GENERATORS RIGSAFE

    Model

    Rating

    Frequency Hz

    Voltage Range V

    Power capacity1 kVA

    kW

    Output2 A

    Breaker 4P A

    Fuel tank L

    Fuel consumption3 l/hr

    Running time hr

    Dimensions [LxWxH] mm

    Weight4 without fuel kg

    Weight4 with fuel kg

    Sound level5 dBA

    XQ250E

    Prime Standby Prime Standby

    50 60

    400V / 230V 480V / 277V

    250 275 250 275

    200 220 200 220

    360 395 305 331

    400

    1200

    35,2 42,1 41,5 48,9

    34 29 29 25

    4600 x 1800 x 2616

    6210

    7410

    66,9 66,9 68,9 68,9

    XQ500E

    Prime Standby Prime Standby

    50 60

    400V / 230V 480V / 277V

    500 550 500 562,5

    400 440 400 440

    722 795 605 677

    800

    1250

    72,6 91,2 81,3 89,6

    17 14 15 14

    5400 x 2100 x 3130

    8875

    9683

    66,8 66,8 68,8 68,8

    V1 /

    12.1

    6 / E

    NER

    GYS

    T

    ENERGYST CAT RENTAL POWER IS BUILT ON THE LATEST OFFSHORE REQUIREMENTSTO MEET THE DEMANDS OF THE INDUSTRY.

    OFFSHORE POWER GENERATORS RIGSAFE

    ENERGYSTOFFSHORE POWER GENERATORS SPECIFICATION

    At Energyst we know that safety is a prerequisite in the offshore industry. That is why, together with our partner Caterpillar, we put real energy into designing the best offshore generators available in the market.

    Energyst’s diesel driven Rig Safe generators are manufactured by Caterpillar and are housed in a custom designed offshore rental package comprising of a canopied generator in a DNV 2.7-1 certified lifting frame. The package has been designed to provide flexibility for all types of end user operation. The equipment packages are classified for use in non-hazardous zone.

    The key safety features outlined within the XQ power modules are: air shut off, spark arrestor, emergency stop, stainless steel braided fuel lines, anti-static drive belts and ‘Yellow Alert’ rig ESD.

    Our offshore equipment range also includes transformers, fuel tanks and NORSOK generators.

    1 Chalwyn Valve

    2 Exhaust Spark Arrestor

    3 ESD Button

    4 Anti static drive belts

    5 Battery Isolation

    6 Yellow alert shutdown module

    7 DNV 2.7-1 Offshore lifting frame

    8 Generator earth bonded to DNV Frame

    9 Braided fuel hoses

    10 Front line spares kit

    11 Certification document pack

    OUTLINE TECHNICAL/SAFETY SPECIFICATION

    TECHNICAL INFORMATION

    OUTLINE TECHNICAL /SAFETY SPECIFICATION

    At Energyst we know that safety is a prerequisite in the offshore industry. That is why, together with our partner Caterpillar, we put real energy into designing the best offshore generators available in the market.

    Energyst’s diesel driven Rig Safe generators are manufactured by Caterpillar and are housed in a custom designed offshore rental package comprising of a canopied generator in a DNV 2.7-1 certifi ed lifting frame. The package has been designed to provide fl exibility for all types

    of end user operation. The equipment packages are classifi ed for use in non-hazardous zone.

    The key safety features outlined within the XQ power modules are: air shut off, spark arrestor, emergency stop, stainless steel braided fuel lines, anti-static drive belts and ‘Yellow Alert’ rig ESD.

    Our offshore equipment range also includes transformers, fuel tanks and NORSOK generators.

    Our heat pump rental solutions are stand-alone, closed packaged systems. They can supply hot and cold water that is transported through flexible high-pressure hoses to distribution devices.

    All our units have a standard design to make assembly, disassembly, installation and maintenance quick and easy. They are easy to transport with a forklift or a crane. They of course come complete with all the ancillaries and fittings you’ll need – like electric cables and water hoses.

    STAND-ALONE & EFFICIENT HEAT PUMP RENTAL

    ENERGYST HEAT PUMPSSPECIFICATION

    HEAT PUMPS 100-300 KW

    ENERGYST CAT RENTAL POWER IS BUILT ON THE LATEST OFFSHOREREQUIREMENTS TO MEET THE DEMANDS OF THE INDUSTRY.

    1. Performance data quoted in accordance with ISO 8528-1 2. Amps 50Hz at 400V | 60Hz at 480V 3. Fuel consumption measured at 75% load | Fuel density is 850 G/L 4. Includes oil and coolant, excludes slings 5. Sound levels given at 75% prime power load 50Hz at 7m | Sound data 60Hz is estimated 2 dBA more than 50Hz based on bare engine data

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    TECHNICAL INFORMATIONTECHNICAL INFORMATION

    WE’D LIKE TO HEAR FROM YOU

    CALL US: 00800 3637 4978EMAIL US: [email protected]

    If you would like to talk to us, request a rental or have a question there are two ways to contact us.

    OFFSHORE POWER GENERATORS RIGSAFE

    Model

    Rating

    Frequency Hz

    Voltage Range V

    Power capacity1 kVA

    kW

    Output2 A

    Breaker 4P A

    Fuel tank L

    Fuel consumption3 l/hr

    Running time hr

    Dimensions [LxWxH] mm

    Weight4 without fuel kg

    Weight4 with fuel kg

    Sound level5 dBA

    XQ250E

    Prime Standby Prime Standby

    50 60

    400V / 230V 480V / 277V

    250 275 250 275

    200 220 200 220

    360 395 305 331

    400

    1200

    35,2 42,1 41,5 48,9

    34 29 29 25

    4600 x 1800 x 2616

    6210

    7410

    66,9 66,9 68,9 68,9

    XQ500E

    Prime Standby Prime Standby

    50 60

    400V / 230V 480V / 277V

    500 550 500 562,5

    400 440 400 440

    722 795 605 677

    800

    1250

    91,2 81,3 89,6

    17 14 15 14

    5400 x 2100 x 3130

    8875

    9683

    66,8 66,8 68,8 68,8

    V1 /

    12.1

    6 / E

    NER

    GYST

    TECHNICAL INFORMATION

    WE’D LIKE TO HEAR FROM YOU

    CALL US: 00800 3637 4978EMAIL US: [email protected]

    If you would like to talk to us, request a rental or have a question there are two ways to contact us.

    OFFSHORE POWER GENERATORS RIGSAFE

    Model

    Rating

    Frequency Hz

    Voltage Range V

    Power capacity1 kVA

    kW

    Output2 A

    Breaker 4P A

    Fuel tank L

    Fuel consumption3 l/hr

    Running time hr

    Dimensions [LxWxH] mm

    Weight4 without fuel kg

    Weight4 with fuel kg

    Sound level5 dBA

    XQ250E

    Prime Standby Prime Standby

    50 60

    400V / 230V 480V / 277V

    250 275 250 275

    200 220 200 220

    360 395 305 331

    400

    1200

    35,2 42,1 41,5 48,9

    34 29 29 25

    4600 x 1800 x 2616

    6210

    7410

    66,9 66,9 68,9 68,9

    XQ500E

    Prime Standby Prime Standby

    50 60

    400V / 230V 480V / 277V

    500 550 500 562,5

    400 440 400 440

    722 795 605 677

    800

    1250

    7 91,2 81,3 89,6

    17 14 15 14

    5400 x 2100 x 3130

    8875

    9683

    66,8 66,8 68,8 68,8

    V1 /

    12.1

    6 / E

    NER

    GYST

    1 Performance data quoted in accordance with ISO 8528-1

    2 Amps 50Hz at 400V, 60Hz at 480V

    3 Fuel consumption measured at 75% load. Fuel density is 850 G/L

    4 includes oil and coolant, excludes slings.

    5 Sound levels given at 75% prime power load 50 Hz at 7m, Sound data 60 Hz is estimated 2 dBa more then 50 Hz based on bare engine data.

    6 Design data

    7 Data at 100% load

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    60Hz versions available on request

    The majority of our rental solutions is equipped with remote monitoring.

    Model

    Rating

    Frequency

    Voltage Range

    Power capacity1

    Output

    Breaker 4P

    Fuel tank

    Fuel consumption3

    Running time

    Dimensions [LxWxH]

    Including offshoreframe

    Weight4 without fuel

    Including offshoreframe

    Weight4 with fuel

    Including offshoreframe

    Sound level5

    XQ500E

    Prime Standby Prime Standby

    50 60

    400V / 230V 480V / 277V

    500 550 500 562,5

    400 440 400 440

    722 795 605 677

    800

    1250

    72.6 91.2 81.3 89.6

    17 14 15 14

    4995 x 1798 x 2513

    5650 x 2200 x 2966

    6225

    8875

    7033

    9683

    66.8 66.8 68.8 68.8

    XQ250E

    Prime Standby Prime Standby

    50 60

    400V / 230V 480V / 277V

    250 275 250 275

    200 220 200 220

    360 395 305 331

    400

    1200

    35.2 42.1 41.5 48.9

    34 29 29 25

    4150 x 1395 x 2140

    4600 x 1800 x 2616

    4110

    6210

    5310

    7410

    66.9 66.9 68.9 68.9

    Hz

    V

    kVA

    kW

    A2

    A

    L

    L/hr

    hr

    mm

    mm

    kg

    kg

    kg

    kg

    dBA

    60 Hz versions available on request.The majority of our generators is equipped with remote monitoring.

    1. Performance data quoted in accordance with ISO 8528-1 2. Amps 50Hz at 400V, 60Hz at 480V 3. Fuel consumption measured at 75% load. Fuel density is 850 G/L 4. Includes oil and coolant, excludes slings.

    5. Sound levels given at 75% prime power load 50 Hz at 7m, Sound data 60 Hz is estimated 2 dBa more then 50 Hz based on bare engine data.

    6. Design data 7. Data at 100% load

    OFFSHORE POWER GENERATORS RIGSAFE

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    https://www.energyst.com/uk/news/offshore-power-generator/https://www.energyst.com/uk/

  • TECHNICAL INFORMATION

    For an effi cient operation of our generators Energyst offers a range of ancillaries for rent, including effi cient and environmentally-safe diesel fuel tanks. Our range of fuel tank hire solutions is UN compliant and in conformity with IBC environmental regulations. They allow environmentally safe supply of fuel to Energyst equipment where an auxiliary source is required or if the equipment’s own internal tank does not allow suffi cient running time.

    The robust CSC plated, pressure tested containers are equipped with quick release couplings, fork lift pockets on four sides and a lockable, vandal-proof access hatch. They ensure safe and secure containment of bulk fuel supplies for generators, heaters and hot water systems.

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    WE’D LIKE TO HEAR FROM YOU

    CALL US: 00800 3637 4978EMAIL US: [email protected]

    If you would like to talk to us, request a rental or have a question there are two ways to contact us.

    TECHNICAL INFORMATIONModel 1000 3000 8000 15000 27000

    Tank size / capacity ltr 1,000 3,000 8,000 15,000 27,000

    Type - Eurocube IBC Eurocube IBC 10 ft ISO container 20 ft ISO container CSC

    plated20 ft HC container

    Connections 3/8” - 2 2 - - -

    Connections 3/4” - 2 2 2 3 8

    Connections 1” - 1 1 2 4 0

    Bund alarm - Electronic Electronic Visual Visual No

    Inspection manhole - 1 1 1 2 2

    Heater connection - 2" 2" - 2" 2"

    Dipstick - No No No Yes No

    Forklift pockets - 2 sides 2 sides 1 side 1 side No

    Fuel fill - 3" 3" 2" 3" 3"

    Grenzwertgeber fill connection

    - Yes Yes Yes Yes No

    Lockable - Yes Yes Yes Yes Yes

    Dimensions [LxWxH] mm 1200 x 1200 x 1250 2400 x 1200 x 1600 2991 x 2438 x 2438 6058 x 2348 x 2590 6058 x 2348 x 2900

    Weight empty kg 450 950 4400 6250 8500

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    FUEL TANKS 1,000 – 27,000 LITRES

    Our heat pump rental solutions are stand-alone, closed packaged systems. They can supply hot and cold water that is transported through flexible high-pressure hoses to distribution devices.

    All our units have a standard design to make assembly, disassembly, installation and maintenance quick and easy. They are easy to transport with a forklift or a crane. They of course come complete with all the ancillaries and fittings you’ll need – like electric cables and water hoses.

    STAND-ALONE & EFFICIENT HEAT PUMP RENTAL

    ENERGYST HEAT PUMPSSPECIFICATION

    HEAT PUMPS 100-300 KW

    OUR FUEL TANKS ARE SPECIALLY DESIGNED TO COMPLEMENT OURPOWER GENERATION AND TEMPERATURE CONTROL RENTAL FLEET

    TECHNICAL INFORMATION

    For an effi cient operation of our generators Energyst offers a range of ancillaries for rent, including effi cient and environmentally-safe diesel fuel tanks. Our range of fuel tank hire solutions is UN compliant and in conformity with IBC environmental regulations. They allow environmentally safe supply of fuel to Energyst equipment where an auxiliary source is required or if the equipment’s own internal tank does not allow suffi cient running time.

    The robust CSC plated, pressure tested containers are equipped with quick release couplings, fork lift pockets on four sides and a lockable, vandal-proof access hatch. They ensure safe and secure containment of bulk fuel supplies for generators, heaters and hot water systems.

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    WE’D LIKE TO HEAR FROM YOU

    CALL US: 00800 3637 4978EMAIL US: [email protected]

    If you would like to talk to us, request a rental or have a question there are two ways to contact us.

    TECHNICAL INFORMATIONModel 1000 3000 8000 15000 27000

    Tank size / capacity ltr 1,000 3,000 8,000 15,000 27,000

    Type - Eurocube IBC Eurocube IBC 10 ft ISO container 20 ft ISO container CSC

    plated20 ft HC container

    Connections 3/8” - 2 2 - - -

    Connections 3/4” - 2 2 2 3 8

    Connections 1” - 1 1 2 4 0

    Bund alarm - Electronic Electronic Visual Visual No

    Inspection manhole - 1 1 1 2 2

    Heater connection - 2" 2" - 2" 2"

    Dipstick - No No No Yes No

    Forklift pockets - 2 sides 2 sides 1 side 1 side No

    Fuel fill - 3" 3" 2" 3" 3"

    Grenzwertgeber fill connection

    - Yes Yes Yes Yes No

    Lockable - Yes Yes Yes Yes Yes

    Dimensions [LxWxH] mm 1200 x 1200 x 1250 2400 x 1200 x 1600 2991 x 2438 x 2438 6058 x 2348 x 2590 6058 x 2348 x 2900

    Weight empty kg 450 950 4400 6250 8500

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    FUEL TANKS 1,000 – 27,000 LITRES

    Our heat pump rental solutions are stand-alone, closed packaged systems. They can supply hot and cold water that is transported through flexible high-pressure hoses to distribution devices.

    All our units have a standard design to make assembly, disassembly, installation and maintenance quick and easy. They are easy to transport with a forklift or a crane. They of course come complete with all the ancillaries and fittings you’ll need – like electric cables and water hoses.

    STAND-ALONE & EFFICIENT HEAT PUMP RENTAL

    ENERGYST HEAT PUMPSSPECIFICATION

    HEAT PUMPS 100-300 KW

    OUR FUEL TANKS ARE SPECIALLY DESIGNED TO COMPLEMENT OURPOWER GENERATION AND TEMPERATURE CONTROL RENTAL FLEET

    TECHNICAL INFORMATION

    WE’D LIKE TO HEAR FROM YOU

    CALL US: 00800 3637 4978EMAIL US: [email protected]

    If you would like to talk to us, request a rental or have a question there are two ways to contact us.

    TECHNICAL INFORMATIONModel 1000 3000 8000 15000 27000

    Tank size / capacity ltr 1,000 3,000 8,000 15,000 27,000

    Type - Eurocube IBC Eurocube IBC 10 ft ISO container 20 ft ISO container CSC

    plated20 ft HC container

    Connections 3/8” - 2 2 - - -

    Connections 3/4” - 2 2 2 3 8

    Connections 1” - 1 1 2 4 0

    Bund alarm - Electronic Electronic Visual Visual No

    Inspection manhole - 1 1 1 2 2

    Heater connection - 2" 2" - 2" 2"

    Dipstick - No No No Yes No

    Forklift pockets - 2 sides 2 sides 1 side 1 side No

    Fuel fill - 3" 3" 2" 3" 3"

    Grenzwertgeber fill connection

    - Yes Yes Yes Yes No

    Lockable - Yes Yes Yes Yes Yes

    Dimensions [LxWxH] mm 1200 x 1200 x 1250 2400 x 1200 x 1600 2991 x 2438 x 2438 6058 x 2348 x 2590 6058 x 2348 x 2900

    Weight empty kg 450 950 4400 6250 8500

    Details are given for guidance only. Exact equipment may vary according to geographical location and availability.

    FUEL TANKS 1,000 – 27,000 LITRES

    WE’D LIKE TO HEAR FROM YOU

    CALL US: 00800 3637 4978EMAIL US: [email protected]

    If you would like to talk to us, request a rental or have a question there are two ways to contact us.

    TECHNICAL INFORMATIONModel 1000 3000 8000 15000 27000

    Tank size / capacity ltr 1,000 3,000 8,000 15,00