Re Rein Detailing

Embed Size (px)

Citation preview

  • 7/31/2019 Re Rein Detailing

    1/47

    REINFORCING DETAILING

    OF R.C.C MEMBERS

    PRESENTED BY

    Er.T.RANGARAJAN,B.E,M.Sc(struct.engg),F.I.E,FACCE,LACI,LISSE,LIASE

    www.engineeringcivil.com

  • 7/31/2019 Re Rein Detailing

    2/47

    WHO IS AN ENGINEER?

    According to USA President Herbert Hoover, who

    was an engineer before he became a politician, said:The great liability of the engineer compared to menof other professionsis that his works are out inthe open where all can see them.His acts ..step by step are in hard substances.

    He cannot bury his mistakes in the grave like theDOCTORS.He cannot argue them into thin air..or blame thejudge..like the LAWYERS.He cannot, like the ARCHITECT, cover his figures

    with trees and vines.He cannot, like the politicians, screen hisshortcomings by blaming his opponents.and hopethe people will forget. The ENGINEER simply cannotdeny he did it.

    If his works do not workhe is damned.

  • 7/31/2019 Re Rein Detailing

    3/47

    A design engineers responsibility should includeassuring the structural safety of the design,details, checking shop drawing.

    Detailing is as important as design since properdetailing of engineering designs is an essentiallink in the planning and engineering process assome of the most devasting collapses in historyhave been caused by defective connections or

    DETAILING. There are many examples explainedin the book" DESIGN AND CONSTRUCTIONFAILURES by Dov Kaminetzky.

    Detailing is very important not only for theproper execution of the structures but for the

    safety of the structures.Detailing is necessary not only for the steelstructures but also for the RCC members as it isthe translation of all the mathematicalexpressions and equations results.

  • 7/31/2019 Re Rein Detailing

    4/47

    For the RCC members for most commonly used for buildings we candivide the detailing for

    1. SLABS-WITH OR WITHOUT OPENINGS.(RECTANGULAR,CIRCULAR,NON-RECTANGULAR-PYRAMID SLAB,TRIANGULAR ETC)

    -BALCONY SLAB,LOFT SLAB,CORNER SLAB etc

    2. BEAMS- WITH OR WITHOUT OPENIGS.(SHALLOW & DEEP BEAMS)

    3. COLUMNS.(RECTANGULAR,L-SHAPE,T-SHAPE,CIRCULAR,OCTAGONAL,CROSS SHAPE etc)

    4. FOUNDATIONS.

    Detailing for gravity loads is different from the lateral loads specially forthe SEISMIC FORCES.

    Apart from the detailing for the above there is a different detailingrequired for the Rehabilitation and strengthening of damaged structures.

    We will now dwell on the DETAILING OF MEMBERS FOR THE GRAVITYAND SOME CODAL DETAILINGS AS PER IS CODE IS 13920 AND IS 4326AS REQUIRED FOR SEISMIC FORCES.

  • 7/31/2019 Re Rein Detailing

    5/47

    DOS & DONOTS FOR DETAILING

    DOS-GENERAL

    1. Prepare drawings properly & accurately if possible label each bar

    and show its shape for clarity.

    12

    I dia@12c/c

    Cross section of retaining wall which collapsed immediately after placing of soilbackfill because rather than 1-1/4 dia. were used. Error occurred because

    Correct rebar dia. Was covered by a dimension line.

    1- dia@12c/c

  • 7/31/2019 Re Rein Detailing

    6/47

    2. Prepare bar-bending schedule , if necessary.3. Indicate proper cover-clear cover, nominal cover

    or effective cover to reinforcement.4. Decide detailed location of opening/hole andsupply adequate details for reinforcementsaround the openings.

    5. Use commonly available size of bars and spirals.

    For a single structural member the number ofdifferent sizes of bars shall be kept minimum.6. The grade of the steel shall be clearly stated in

    the drawing.7. Deformed bars need not have hooks at their

    ends.8. Show enlarged details at corners, intersections

    of walls, beams and column joint and at similarsituations.

  • 7/31/2019 Re Rein Detailing

    7/47

    9. Congestion of bars should be avoided at points wheremembers intersect and make certain that all rein. Can beproperly placed.

    10. In the case of bundled bars, lapped splice of bundled barsshall be made by splicing one bar at a time; suchindividual splices within the bundle shall be staggered.

    11. Make sure that hooked and bent up bars can be placedand have adequate concrete protection.

  • 7/31/2019 Re Rein Detailing

    8/47

    12. Indicate all expansion, construction and contraction jointson plans and provide details for such joints.

    13. The location of construction joints shall be at the point ofminimum shear approximately at mid or near the mid points.It shall be formed vertically and not in a sloped manner.

    DOS BEAMS & SLABS:

    1. Where splices are provided in bars, they shall be , as far aspossible, away from the sections of maximum stresses andshall be staggered.

    2. Were the depth of beams exceeds 750mm in case of beamswithout torsion and 450mm with torsion provide face rein.as per IS456-2000.

    3. Deflection in slabs/beams may be reduced by providingcompression reinforcement.

    4. Only closed stirrups shall be used for transverse rein. Formembers subjected to torsion and for members likely to besubjected to reversal of stresses as in Seismic forces.

  • 7/31/2019 Re Rein Detailing

    9/47

    5. To accommodate bottom bars, it is good practice to makesecondary beams shallower than main beams, at least by50mm.

    Dos COLUMNS.1. A reinforced column shall have at least six bars of

    longitudinal reinforcement for using in transverse helicalreinforcement.-for CIRCULAR sections.

    2. A min four bars one at each corner of the column in thecase of rectangular sections.

    3. Keep outer dimensions of column constant, as far aspossible , for reuse of forms.

    4. Preferably avoid use of 2 grades of vertical bars in thesame element.

    DONOTS-GENERAL:

    1. Reinforcement shall not extend across an expansion jointand the break between the sections shall be complete.

    2. Flexural reinforcement preferably shall not be terminatedin a tension zone.

  • 7/31/2019 Re Rein Detailing

    10/47

    3. Bars larger than 36mm dia. Shall not be bundled.

    4. Lap splices shall be not be used for bars larger than36mm dia. Except where welded.

    5. Where dowels are provided, their diameter shall notexceed the diameter of the column bars by more than3mm.

    6. Where bent up bars are provided, their contributiontowards shear resistance shall not be more than 50% of

    the total shear to be resisted. USE OF SINGEL BENT UPBARS(CRANKED) ARE NOT ALLOWED IN THE CASEOF EARTHQUAKE RESISTANCE STRUCTURES.

  • 7/31/2019 Re Rein Detailing

    11/47

    DETAILING OF SLABS WITHOUT ANY CUTOR OPENINGS.

    The building plan DX-3 shows theslabs in different levels for thepurpose of eliminating the inflow of

    rainwater into the room from the openterrace and also the sunken slab fortoilet in first floor.

    The building plan DX-A3 is one inwhich the client asked the architect toprovide opening all round.

    Refer the 3d

    elevation

  • 7/31/2019 Re Rein Detailing

    12/47

    Different shapes of slabs used in thebuildings. 6depression for OT &

    9 for sunken slabs.

    Portico slab in elevation

    19-6

    9-6suareopening

    5wide corridor all

    round

    Portico and other roomsroof slab in plan

    Portico slab in plan

  • 7/31/2019 Re Rein Detailing

    13/47

    Minimum and max.reinforcement % in beams, slabs andcolumns as per codal provisions should be followed.

    SLABS:

    It is better to provide a max spacing of 200mm(8) for main

    bars and 250mm(10) in order to control the crack width and

    spacing.

    A min. of 0.24% shall be used for the roof slabs since it issubjected to higher temperature. Variations than the floorslabs. This is required to take care of temp. differences.

    It is advisable to not to use 6mm bars as main bars as thissize available in the local market is of inferior not only withrespect to size but also the quality since like TATA and SAILare not producing this size of bar.

    BEAMS:

    A min. of 0.2% is to be provided for the compression bars inorder to take care of the deflection.

  • 7/31/2019 Re Rein Detailing

    14/47

    The stirrups shall be min.size of8mm in the case of lateral load

    resistance .The hooks shall be bent to 135degree .

  • 7/31/2019 Re Rein Detailing

    15/47

    Ld/2Ld/2

    Ld

    crack

    INCORRECT

    CORRECT

    CLOSESTIRRUPS

    Ldt

    Ldt/2

    CANTILEVER BEAM

  • 7/31/2019 Re Rein Detailing

    16/47

    NON PRISMATIC BEAM

    Ld/2 Ld/2Ld

    INCORRECT

    CORRECT

    CLOSESTIRRUPS

    crack

    Ldt/2

    Ldt

    GRID BEAM

  • 7/31/2019 Re Rein Detailing

    17/47

    GRID BEAMGRID BEAM

    INCORRECT

    1.5d1.5d1.5d

    Close rings

    Hanger bars

    Slope 1:10

    2#extra bars

    300300

    d

    CORRECT

  • 7/31/2019 Re Rein Detailing

    18/47

    Details of Main & Secondary beams

    INCORRECT

    1.5d1.5d1.5d

    Close rings

    Hanger bars

    300300

    d

    CORRECT

    Secondary beam

    Main beam

    Secondary beam

    60degree

    Main beam

  • 7/31/2019 Re Rein Detailing

    19/47

    d

    1/4OR1/5 SPAN

    1.5d

    CORRECT

    INCORRECT

    d/2+d/2Cot(t)

    tt

    Ld

    d/2

    d/2

    LdLINE OF CRACK

    BEAM

  • 7/31/2019 Re Rein Detailing

    20/47

    Continuous beam

    continuous beamSpan/4

    Span/4Span/4

    Span/4

    incorrect

    Span/4

    Span/4

    1.5d1.5d

    Span/4

    correct

    1.5d

  • 7/31/2019 Re Rein Detailing

    21/47

    100%

    L1

    100% CRACKCRACK

    .08L2.08L1 L2

    SPAN/4 SPAN/4

    CONTINUOUS BEAM

    INCORRECT

    .08L1

    .08L1

    SPAN/4

    CRACK

    100%

    L1

    100%

    .15L2 L2

    L1/4 L2/4

    CORRECT

    0.1L1

    .15L1

    L1/4100%

    20%20%

  • 7/31/2019 Re Rein Detailing

    22/47

    D

    D

    CRACK

    INCORRECT

    NONPRISMATICSECTION OF BEAM

    D

    D

    DCORRECT

    D

    CLOSE RING

    CLOSE RING

  • 7/31/2019 Re Rein Detailing

    23/47

    COLUMN

    INCORRECT

    CANTILEVER BEAM PROJECTINGFROM COLUMN

    CORRECT

    NOT LESS THAN GREATER OF 0.5L OR Ld50mm

    0.25Ast

    NOT LESSTHAN 0.5Ast

    COLUMN

    Ld

    Ld/3

  • 7/31/2019 Re Rein Detailing

    24/47

    CRACK

    SLOPING BEAM

    CORRECT

    Ld

    Ld

  • 7/31/2019 Re Rein Detailing

    25/47

    CRACKCRACK

    INCORRECT

    HAUNCH BEAMS

    CORRECTL/8 TOL/10 L/8 TO

    L/10

    L

    L

    Ld Ld

    Ld Ld

  • 7/31/2019 Re Rein Detailing

    26/47

    STRESSES AT CORNERS

    C

    C-COMPRESSION

    T-TENSION

    t

    t

    C

    RESULTANT TENSILE STRESS FORACROSS CORNER(ONE PLANE)

    t

    c

    RESULTANT TENSILE STRESS FORACROSS CORNER(DIFFERENT PLANE)t

    c

    CRACK

    CRACK

  • 7/31/2019 Re Rein Detailing

    27/47

    SHEAR AND TORSION REIN. IN

    BEAMS

    INCORRECT

    Min 0.2%bd to control deflection aswell as for seismic requ.

    b

    D100 to

    200mm

    d

    D-n>500mm

    D/5

    Skin rein.10dia isrequired when depth

    exceeds 450mm(0.1%of web area distributedequally on two faces)

    Stirrups taken round outermostbars spacing

  • 7/31/2019 Re Rein Detailing

    28/47

    CANTILEVER BEAM WITH

    POINT LOAD

    CORRECT

    INCORRECT

    2/3dd

    Shear rein.

    Extra ties

    Ld

    Ld

  • 7/31/2019 Re Rein Detailing

    29/47

    opening

    CORRECT

    OPENING IN WEB OF BEAM

    crackcrack

    opening

    INCORRECT

    OPENING IN WEB OF BEAM

    Ld

    d/2 d/2

    Closed stpsfor d/2

    Closed stps

    for d/2

  • 7/31/2019 Re Rein Detailing

    30/47

    BEAM COLUMN JUNCTION-EXTERIOR COLUMN

    CORRECT

    INCORRECT

    CLOSED STPS2max

    IN TENSION-Ld

    U TYPE BARS

    Ld

  • 7/31/2019 Re Rein Detailing

    31/47

    CORRECT

    SPLICE DETAIL FOR COLUMN

    INCORRECT

    COVER

    CLOSETIES @S/2

    S-SPACING

    SLOPE 1:6

  • 7/31/2019 Re Rein Detailing

    32/47

    REDUCTIONCOLUMN BOTHSIDES

    INCORRECT

    CORRECT

    3NO.CLOSE TIES

    SPLICE

    CLOSE STPS SPACIN

  • 7/31/2019 Re Rein Detailing

    33/47

    TERMINATION OF COLUMN BARS INSIDE BEAM

    INCORRECT

    CORRECT

    Ld

  • 7/31/2019 Re Rein Detailing

    34/47

    BEAM COL. JUNCTION-EQREGION

    EQREGION-BEAM-COL JN-EXTERIOR

    CORRECT

    BEAM COL. JUNCTION-EQREGION

    INCORRECT

    END REGION

    END REGION

    COL.

    CORE*

    SPACING OFLATERALTIES

  • 7/31/2019 Re Rein Detailing

    35/47

    COLUMN DETAILS IN EQ REGIONS

    ENDREGION

    ENDREGION

    First stirrups50mm from beam

    face

    Spacing of shear rein. In

    columns

    incorrect

    Spacing of shear rein. Incolumns

    correct

    END REGION-h/6 or D or450MM whichever isgreater

    ENDREGION

    hd

    D

    b

    EQ REGION CONTINUOUS BEAM

  • 7/31/2019 Re Rein Detailing

    36/47

    EQ-REGION-CONTINUOUS BEAM

    INCORRECT

    Ld

    A=L1/3

    CONTINUOUS BARS NOT LESS THAN AREA OF BARS AT COL.FACE

    A=L1/3 A=L1/3

    2d

    50mmmax

    Stirrup spacing=d/4 or

    100mm or 8dia whichever is the least

    2d2d 2dstp@maxd/2 stp@maxd/2

    CORRECT

  • 7/31/2019 Re Rein Detailing

    37/47

    INCORRECT

    FOOTING-DETAILS(INDEPENDENT)

    CORRECT

    COVER TOSTARTER

    STARTERBARS

    COLUMNBARS

    NATURALG.L

    Ldt

    Lb3 SIDE COVER

    LdtCOVER50mmIF p.c.c below

    or 75mm

    Min.300

    TYPICAL REIN DETAILS OF

  • 7/31/2019 Re Rein Detailing

    38/47

    TYPICAL REIN DETAILS OFHAMMER FOUNDATION BLOCKINCORRECT

    CORRECT

    Ld

    Ld

  • 7/31/2019 Re Rein Detailing

    39/47

    SECTION OF TRENCH

    CRACK

    INCORRECTINCORRECT

    CORRECT

    LdLd

    Ld

  • 7/31/2019 Re Rein Detailing

    40/47

    STAIRCASE-WITH WAIST SLAB

    INCORRECT

    CORRECT

    Ld(min)Extra bar

    Ld(min)

    Ld(min)

    SLABLESS STAIRCASE

  • 7/31/2019 Re Rein Detailing

    41/47

    Main bar

    Dist.

    Main bar

    Alternate 1

    SLABLESS STAIRCASE

    SLABLESS STAIRCASE

  • 7/31/2019 Re Rein Detailing

    42/47

    Main bar

    Alternate 2

    A=0.25L

    L=horizontal span

    SLABLESS STAIRCASE

  • 7/31/2019 Re Rein Detailing

    43/47

    DEVELOPMENT LENGTH OF BARS

    SLNO BARDIA.

    TENSIONmm

    COMPRESSION REMARKS

    1 8 376.0 301.0

    2 10 470.0 376.0

    3 12 564.0 451.0

    4 16 752.0 602.0

    5 20 940.0 752.0

    6 22 1034.0 827.0

    7 25 1175.0 940.0

    8 28 1316.0 1053.0

    9 32 1504.0 1203.0

    FOR A CONCRETE GRADE M20 &STEEL STRENGTH Fy=415

    APPROXIMATELY USE 50Xdia FOR TENSION

  • 7/31/2019 Re Rein Detailing

    44/47

    CONCLUSION:Before concluding I will show some more details drawnin autocad exported in wwf format

    As there is no time to elaborately explaining ,the following topics are notcovered :

    1. Flat slabs, Folded plates, shell structures-cylindrical shells, silos,2. Staircases- helical staircase, central beam type, cantilever type etc.3. Different types of foundations-raft, pile foundation, strap foundation etc.4. Retaining wall structures,5. Liquid retaining structures.6. Deep beams.7. Shear wall, walls.

    Hope that I have enlighten some of the detailing technique for the mostcommonly encountered RCC members in buildings.

    In the above statements if my senior colleagues and ACCE memberscan find different method or any new detailing system it will be of immensehelp not only for me but to other young engineers who should learn in wrightways and not wrong lessons.

    REFERENCES

  • 7/31/2019 Re Rein Detailing

    45/47

    REFERENCES:

    1. HANDBOOK ON CONCRETE REINFORCEMENT ANDDETAILING-SP:34(S&T)-1987.

    2. MANUAL OF ENGINEERING & PLACING DRAWINGSFOR REINFORCED CONCRETE STRUCTURES-

    (ACI 315-80

    3. MANUAL OF STANDARD PRACTICECONCRETEREINFORCING STEEL INSTITUTE.

    4. TWARD BOARD MANUAL FOR RURAL WATERSUPPLY SCHEMES.

    5. DESIGN PRINCIPLES AND DETAILING OF CONCRETESTRUCTURES. By D.S.PRAKASH RAO.

    6. SIMPLIFIED DESIGN-RC BUILDINGS OF MODERATESIZE AND HEIGHT-BY PORTLAND CEMENTASSOCIATION,USA.

    7. DESIGN AND CONSTRUCTION FAILURES BY DOVKAMINETZKY.

  • 7/31/2019 Re Rein Detailing

    46/47

    8. IS:2502-1963 CODE OF PRACTICE FOR BENDING ANDFIXING OF BARS FOR CONCRETE REINFORCEMENT.

    9. IS:1893:2000.

    10. IS:4326.11. IS:456:2000

    12. REINFORCED HAND BOOK BY REYNOLD.

  • 7/31/2019 Re Rein Detailing

    47/47

    THANK YOU.

    www.engineeringcivil.com