RAINGARDEN WITH FILTER DRAIN - TYPICAL SECTION 300 Min. PERMEABLE GEOTEXTILE WITH A MIN. 135 l/m²/s AS PER BS EN ISO 10319:2015 300mmØ PERFORATED uPVC PIPE WRAPPED IN PERMEABLE GEOTEXTILE TOPSOIL SHALL MEET REQUIREMENTS OF BS 3882:1994 DESIGN TWL +0.150mm PLANTING TO LANDSCAPE ARCHITECTS DETAIL 75 300 600 600 STORAGE LAYER OF CLEAN CRUSHED, WASHED, 20-50mm ANGULAR STONE WITH POROSITY 30-40% UNDERLYING SOIL MUST NOT BE COMPACTED IN INFILTRATION AREAS 50 FREEBOARD TO GL (150 FREEBOARD TO FFL) INFILTRATION TO GROUNDWATER FROM LAND DRAIN. INFILTRATION TEST TO BE COMPLETED TO DETERMINE INFILTRATION RATE AT EACH PROPOSED LOCATION IN ACCORDANCE WITH BRE GUIDANCE PODIUM SLAB PODIUM PLANTER / BIORETENTION DETAIL 450mm STORAGE LAYER OF CLEAN CRUSHED, WASHED, 20-50mm ANGULAR STONE WITH POROSITY 30% FINISH AS PER LANDSCAPES SPECIFICATION DEPRESSION STORAGE PERMAVOID 150 CELLULAR STORAGE OR SIMILAR APPROVED WRAPPED IN GEOTEXTILE WITH ABSORBENT PHENOLIC FOAM INCORPORATED TO IRRIGATION 300 150 ROOF DRAINAGE TO DISCHARGE TO OGCR SUB BASE INSPECTION CHAMBER PERMAVOID 85 GEOCELLUAR BOX WRAPPED IN GEOTEXTILE TO FORM DIFFUSER 150 DOWNPIPE TO SUB BASE DETAIL 300 PODIUM SLAB TREE PIT - TYPICAL SECTION STORAGE LAYER OF CLEAN CRUSHED, WASHED, 20-50mm ANGULAR STONE WITH POROSITY 30-40% 1000 Min. 25 225 PERMEABLE GEOTEXTILE WITH A MIN. 0.6m/s INFLITRATION RATE AS PER BS EN ISO 10319:2015 INFILTRATION TO GROUNDWATER FROM LAND DRAIN. INFILTRATION TEST TO BE COMPLETED TO DETERMINE INFILTRATION RATE AT EACH PROPOSED LOCATION IN ACCORDANCE WITH BRE GUIDANCE UNDERLYING SOIL MUST NOT BE COMPACTED IN INFILTRATION AREAS 50mm Min. DEPRESSION STORAGE ENGINEERED SOIL AS PER LANDSCAPE ARCHITECTS SPECIFICATION 75 598 250 250 300mmØ PERFORATED uPVC PIPE WRAPPED IN PERMEABLE GEOTEXTILE 150 Min. 100Ø 150 MITRED OUTLET TO MATCH SLOPE WITH SUITABLE AGREED VISUAL CHARACTERISTICS 150mm THICK INSITU GRADE C30 CONCRETE BASE AND SURROUND FLOW CONTROL 200 Min. 150 150 3 1 300 Min. CONCRETE TOE FOR SEDIMENT COLLECTION RAINGARDEN / BIORETENTION 200 Min. 150 3 1 600 Min. RAINGARDEN / BIORETENTION OUTFALL DETAIL - TYPICAL SECTION DEPRESSION STORAGE OUTLET PODIUM SLAB 450mm STORAGE LAYER OF CLEAN CRUSHED, WASHED, 20-50mm ANGULAR STONE WITH POROSITY 40% PERMAVOID, OR SIMILAR CELLULAR STORAGE TO BE PROVIDED IF ADDITIONAL STORAGE IS REQUIRED GREEN ROOFS TO DISCHARGE PLANTER/TREATMENT STORAGE EROSION CONTROL AT DOWNPIPE OUTLET OVERFLOW CONTROL 150 CONCRETE TOE FOR SEDIMENT COLLECTION / ANTI EROSION CONTROL STONE IN STAINLESS STEEL MESH BASKET 750x600x450 RAINGARDEN / BIORETENTION INLET DETAIL - TYPICAL SECTION DOWNPIPE TO PLANTER DETAIL 300 DEPRESSION STORAGE DEPRESSION STORAGE GAPS IN KERB AS SPECIFIED RW HOPPER TO ARCHITECTS DETAIL FLOW CONTROL INSPECTION CHAMBER AS SPECFICED GEOCELLUAR BOX WRAPPED IN GEOTEXTILE TO FORM DIFFUSER PODIUM SLAB PODIUM WATERPROOFING TO ARCHITECT DETAIL DOWNPIPE DROP OFF PODIUM PODIUM WATERPROOFING TO ARCHITECT DETAIL SWALE - TYPICAL SECTION 300 Min. PERMEABLE GEOTEXTILE WITH A MIN. 135 l/m²/s AS PER BS EN ISO 10319:2015 300mmØ PERFORATED uPVC PIPE WRAPPED IN PERMEABLE GEOTEXTILE TOPSOIL SHALL MEET REQUIREMENTS OF BS 3882:1994 VARIES DESIGN TWL PLANTING TO LANDSCAPE ARCHITECTS DETAIL 75 300 600 600 GRASS REINFORMCEMENT SYSTEM TO SWALE SIDES IN ACCORDANCE WITH BS 6717:2001 STORAGE LAYER OF CLEAN CRUSHED, WASHED, 20-50mm ANGULAR STONE WITH POROSITY 30-40% UNDERLYING SOIL MUST NOT BE COMPACTED IN INFILTRATION AREAS 3 1 150 FREEBOARD INFILTRATION TO GROUNDWATER FROM LAND DRAIN. INFILTRATION TEST TO BE COMPLETED TO DETERMINE INFILTRATION RATE AT EACH PROPOSED LOCATION IN ACCORDANCE WITH BRE GUIDANCE VARIES 150 FREEBOARD SLOT DRAIN & FILTER DRAIN - TYPICAL SECTION PERMEABLE GEOTEXTILE WITH A MIN. 135 l/m²/s AS PER BS EN ISO 10319:2015 300mmØ PERFORATED uPVC PIPE WRAPPED IN PERMEABLE GEOTEXTILE CLEAN CRUSHED, WASHED, 20-50mm ANGULAR STONE POROSITY 30-40% 75 300 600 600 300 UNDERLYING SOIL MUST NOT BE COMPACTED IN INFILTRATION AREAS INFILTRATION TO GROUNDWATER FROM LAND DRAIN. INFILTRATION TEST TO BE COMPLETED TO DETERMINE INFILTRATION RATE AT EACH PROPOSED LOCATION IN ACCORDANCE WITH BRE GUIDANCE RAIN WATER DIFFFUSER CHAMBER BRICKSLOT TYPE CHANNEL 150 - PLANTING TO LANDSCAPE ARCHITECTS DETAIL OVER LAND FLOW OVER LAND FLOW TO FLOW CONTROL - PLANTING TO LANDSCAPE ARCHITECTS DETAIL OVER LAND FLOW 1:10 SLOPE FLOW - PLANTING TO LANDSCAPE ARCHITECTS DETAIL - PLANTING TO LANDSCAPE ARCHITECTS DETAIL TO FLOW CONTROL FALL 85 PERMAVOID 150 GEOCELLULAR STORAGE OR SIMILAR APPROVED WRAPPED IN GEOTEXTILE 150 INDICATES MAX. TOP DESIGN WATER STORAGE LEVEL FOR 1% AEP STORM TWL TWL TWL 150 300 85 TWL PERMAVOID 150 GEOCELLULAR STORAGE OR SIMILAR APPROVED WRAPPED IN GEOTEXTILE PERMAVOID 85 GEOCELLULAR STORAGE OR SIMILAR APPROVED WRAPPED IN GEOTEXTILE 50mm LAYING COURSE (6mm AGGREGATE) PERMEABLE PAVING BLOCKS JOINTING (6mm AGGREGATE) 450 STORAGE LAYER OF CLEAN CRUSHED, WASHED, 20-50mm ANGULAR STONE WITH POROSITY 30-40% IMPERMEABLE MEMBRANE PERMEABLE PAVING DETAIL (ON-PODIUM) SECTION PROTECTED ORIFICE TO CONTROL FLOW RATE & DESIGN HEAD AS PER PLAN DRAWING OVERFLOW WEIR CONTROFLOW 600 SERIES LEVEL INVERT OR EQUAL APPROVED FLOW CONTROL CHAMBER FLOW CONTROL GREEN ROOF - TYPICAL SECTION Vegetation Barrier 100mm BAUDER GREEN ROOF PARAPET UPSTAND BAUDER GREEN ROOF OUTLET ALU 250 INSPECTION CHAMBER. HEIGHT EXTENSION PIECE AVAILABLE. Vegetation Barrier 100mm Min.150mm GREEN ROOF DESIGN BY LANDSCAPE ARCHITECT OR DESIGN SPECIALIST PERMAVOID 150 GEOCELLULAR STORAGE OR SIMILAR APPROVED WRAPPED IN GEOTEXTILE OVERFLOW WEIR PERMAVOID CELLULAR STORAGE, OR SIMILAR PODIUM SLAB PODIUM WATERPROOFING TO ARCHITECT DETAIL 50mm LAYING COURSE (6mm AGGREGATE) PERMEABLE PAVING BLOCKS JOINTING (6mm AGGREGATE) 450 STORAGE LAYER OF CLEAN CRUSHED, WASHED, 20-50mm ANGULAR STONE WITH POROSITY 30-40% PERMEABLE GEOTEXTILE WITH A MIN. 0.6m/s INFLITRATION RATE AS PER BS EN ISO 10319:2015 INFILTRATION TO GROUNDWATER FROM LAND DRAIN. INFILTRATION TEST TO BE COMPLETED TO DETERMINE INFILTRATION RATE AT EACH PROPOSED LOCATION IN ACCORDANCE WITH BRE GUIDANCE UNDERLYING SOIL MUST NOT BE COMPACTED IN INFILTRATION AREAS PERMEABLE PAVING DETAIL (OFF-PODIUM) SECTION PERMAVOID CELLULAR STORAGE, OR SIMILAR Head Office, 9 Prussia Street, Dublin 7. D07 KT57 TEL +353 (0)1 8682000 e: [email protected] w: www.ocsc.ie Drn by: Aprvd by: Chkd by: Code Status Revision Date: Scale: @ A1 Project: Title: Originator Zone Type Role Number Level Rev No. Date Revision Note Drn by Chkd by · FOR SETTING OUT REFER TO ARCHITECT'S DRAWINGS. · THIS DRAWING TO BE READ IN CONJUNCTION WITH ALL OTHER ARCHITECTURAL AND ENGINEERING DRAWINGS AND ALL OTHER RELEVANT DRAWINGS AND SPECIFICATIONS. · DO NOT SCALE THIS DRAWING. USE FIGURED DIMENSIONS ONLY. · NO PART OF THIS DOCUMENT MAY BE REPRODUCED OR TRANSMITTED IN ANY FORM OR STORED IN ANY RETRIEVAL SYSTEM OF ANY NATURE WITHOUT THE WRITTEN PERMISSION OF O'CONNOR SUTTON CRONIN AS COPYRIGHT HOLDER EXCEPT AS AGREED FOR USE ON THE PROJECT FOR WHICH THE DOCUMENT WAS ORIGINALLY ISSUED. - - - Client: Drn by Chkd by - - - Dublin London Belfast Galway Cork Rev No. Date Revision Note ENVIRONMENT QUALITY HEALTH & SAFETY ISO 14001:2015 ISO 9001:2015 OHSAS 18001:2007 NSAI Certified NSAI Certified NSAI Certified BIM Verified Design & Construction Capital/Delivery PAS 1192-2 bsi. O'CONNOR SUTTON CRONIN Multidisciplinary Consulting Engineers Sandyford GP Limited. Sandyford Central SuDs Details SFC OCSC 00 XX DR C 0510 A1 C02 28.02.19 n.t.s. JB AH MMcG P01 28.02.19 SUITABLE FOR INFORMATION JB AH P02 14.06.19 SUITABLE FOR INFORMATION JB PR C01 19.07.19 PAC SUBMISSION JS JB P03 12.11.2019 SUITABLE FOR INFORMTION MK AH C02 19.11.2019 STAGE COMPLETE - PLANNING MK PR PLANNING DRAWING. NOT FOR CONSTRUCTION. ALL LEVELS GIVEN ARE RELATIVE TO ORDNANCE DATUM. THIS DRAWING HAS BEEN ISSUED FOR INFORMATION PURPOSES ONLY AND MUST NOT BE USED FOR CONSTRUCTION UNDER ANY CIRCUMSTANCES

RAINGARDEN / BIORETENTION INLET DETAIL - TYPICAL SECTION€¦ · permavoid 85 geocellular storage or similar approved wrapped in geotextile 50mm laying course (6mm aggregate) permeable

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

RAINGARDEN WITH FILTER DRAIN - TYPICAL SECTION

30

0 M

in

.

PERMEABLE GEOTEXTILE

WITH A MIN. 135 l/m²/s AS

PER BS EN ISO 10319:2015

300mmØ PERFORATED

uPVC PIPE WRAPPED IN

PERMEABLE GEOTEXTILE

TOPSOIL SHALL MEET

REQUIREMENTS OF

BS 3882:1994

DESIGN TWL +0.150mm

PLANTING TO LANDSCAPE

ARCHITECTS DETAIL

75

300

600

60

0

STORAGE LAYER OF CLEAN

CRUSHED, WASHED, 20-50mm

ANGULAR STONE WITH

POROSITY 30-40%

UNDERLYING SOIL MUST

NOT BE COMPACTED IN

INFILTRATION AREAS

50

F

RE

EB

OA

RD

T

O

GL

(1

50

F

RE

EB

OA

RD

TO

F

FL

)

INFILTRATION TO GROUNDWATER

FROM LAND DRAIN. INFILTRATION

TEST TO BE COMPLETED TO

DETERMINE INFILTRATION RATE

AT EACH PROPOSED LOCATION IN

ACCORDANCE WITH BRE

GUIDANCE

PODIUM SLAB

PODIUM PLANTER / BIORETENTION DETAIL

450mm STORAGE LAYER OF

CLEAN CRUSHED, WASHED,

20-50mm ANGULAR STONE

WITH POROSITY 30%

FINISH AS PER LANDSCAPES

SPECIFICATION

DEPRESSION

STORAGE

PERMAVOID 150 CELLULAR

STORAGE OR SIMILAR

APPROVED WRAPPED IN

GEOTEXTILE WITH

ABSORBENT PHENOLIC FOAM

INCORPORATED TO IRRIGATION

30

0

15

0

ROOF DRAINAGE

TO DISCHARGE TO

OGCR SUB BASE

INSPECTION CHAMBER

PERMAVOID 85

GEOCELLUAR BOX

WRAPPED IN GEOTEXTILE

TO FORM DIFFUSER

15

0

DOWNPIPE TO SUB BASE DETAIL

30

0

PODIUM SLAB

TREE PIT - TYPICAL SECTION

STORAGE LAYER OF CLEAN CRUSHED,

WASHED, 20-50mm ANGULAR STONE

WITH POROSITY 30-40%

10

00

M

in

.

25

225

PERMEABLE

GEOTEXTILE WITH

A MIN. 0.6m/s

INFLITRATION RATE

AS PER BS EN ISO

10319:2015

INFILTRATION TO GROUNDWATER FROM

LAND DRAIN. INFILTRATION TEST TO BE

COMPLETED TO DETERMINE INFILTRATION

RATE AT EACH PROPOSED LOCATION IN

ACCORDANCE WITH BRE GUIDANCE

UNDERLYING SOIL MUST NOT

BE COMPACTED IN

INFILTRATION AREAS

50mm Min.

DEPRESSION

STORAGE

ENGINEERED SOIL

AS PER LANDSCAPE

ARCHITECTS

SPECIFICATION

75

598

250

25

0

300mmØ PERFORATED uPVC PIPE

WRAPPED IN PERMEABLE GEOTEXTILE

15

0 M

in

.

10

15

0

MITRED OUTLET TO MATCH

SLOPE WITH SUITABLE

AGREED VISUAL

CHARACTERISTICS

150mm THICK INSITU GRADE C30CONCRETE BASE AND SURROUND

FLOW CONTROL

20

0 M

in

.

15

0

15

0

3

1

300 Min.

CONCRETE TOE FOR

SEDIMENT COLLECTION

RAINGARDEN / BIORETENTION

20

0 M

in

.

15

0

3

1

600 Min.

RAINGARDEN / BIORETENTION OUTFALL DETAIL - TYPICAL SECTION

DEPRESSION

STORAGE

OUTLET

PODIUM SLAB

450mm STORAGE LAYER OF

CLEAN CRUSHED, WASHED,

20-50mm ANGULAR STONE

WITH POROSITY 40%

PERMAVOID, OR SIMILAR

CELLULAR STORAGE TO BE

PROVIDED IF ADDITIONAL

STORAGE IS REQUIRED

GREEN ROOFS TO DISCHARGE

PLANTER/TREATMENT STORAGE

EROSION CONTROL

AT DOWNPIPE OUTLET

OVERFLOW

CONTROL

15

0

CONCRETE TOE FOR

SEDIMENT COLLECTION /

ANTI EROSION CONTROL

STONE IN STAINLESS STEEL

MESH BASKET 750x600x450

RAINGARDEN / BIORETENTION INLET DETAIL - TYPICAL SECTION

DOWNPIPE TO PLANTER DETAIL

30

0

DEPRESSION

STORAGE

DEPRESSION

STORAGE

GAPS IN KERB AS

SPECIFIED

RW HOPPER TOARCHITECTS DETAIL

FLOW CONTROL INSPECTION

CHAMBER AS SPECFICED

GEOCELLUAR BOX

WRAPPED IN GEOTEXTILE

TO FORM DIFFUSER

PODIUM SLAB

PODIUM WATERPROOFINGTO ARCHITECT DETAIL

DOWNPIPE DROP OFF PODIUM

PODIUM WATERPROOFINGTO ARCHITECT DETAIL

SWALE - TYPICAL SECTION

30

0 M

in

.

PERMEABLE GEOTEXTILE

WITH A MIN. 135 l/m²/s AS

PER BS EN ISO 10319:2015

300mmØ PERFORATED

uPVC PIPE WRAPPED IN

PERMEABLE GEOTEXTILE

TOPSOIL SHALL MEET

REQUIREMENTS OF BS 3882:1994

VARIES

DESIGN TWL

PLANTING TO LANDSCAPE

ARCHITECTS DETAIL

75

300

600

60

0

GRASS REINFORMCEMENT

SYSTEM TO SWALE SIDES IN

ACCORDANCE WITH BS 6717:2001

STORAGE LAYER OF CLEAN

CRUSHED, WASHED, 20-50mm

ANGULAR STONE WITH

POROSITY 30-40%

UNDERLYING SOIL MUST

NOT BE COMPACTED IN

INFILTRATION AREAS

3

1

15

0

FR

EE

BO

AR

D

INFILTRATION TO GROUNDWATER

FROM LAND DRAIN. INFILTRATION

TEST TO BE COMPLETED TO

DETERMINE INFILTRATION RATE

AT EACH PROPOSED LOCATION IN

ACCORDANCE WITH BRE

GUIDANCE

VARIES

15

0

FR

EE

BO

AR

D

SLOT DRAIN & FILTER DRAIN - TYPICAL SECTION

PERMEABLE GEOTEXTILE

WITH A MIN. 135 l/m²/s AS

PER BS EN ISO 10319:2015

300mmØ PERFORATED

uPVC PIPE WRAPPED IN

PERMEABLE GEOTEXTILE

CLEAN CRUSHED,

WASHED, 20-50mm

ANGULAR STONE

POROSITY 30-40%

75

300

600

60

0

30

0

UNDERLYING SOIL MUST

NOT BE COMPACTED IN

INFILTRATION AREAS

INFILTRATION TO GROUNDWATER FROM

LAND DRAIN. INFILTRATION TEST TO BE

COMPLETED TO DETERMINE INFILTRATION

RATE AT EACH PROPOSED LOCATION IN

ACCORDANCE WITH BRE GUIDANCE

RAIN WATER DIFFFUSER CHAMBER

BRICKSLOT TYPE CHANNEL

15

0

- PLANTING TO LANDSCAPE

ARCHITECTS DETAIL

OVER LAND FLOWOVER LAND FLOW

TO FLOW CONTROL

- PLANTING TO LANDSCAPE

ARCHITECTS DETAIL

OVER LAND FLOW

1:10 SLO

PE

FLOW

- PLANTING TO LANDSCAPE

ARCHITECTS DETAIL

- PLANTING TO LANDSCAPE

ARCHITECTS DETAIL

TO FLOW CONTROL

FALL

85

PERMAVOID 150 GEOCELLULAR

STORAGE OR SIMILAR

APPROVED WRAPPED IN

GEOTEXTILE

15

0

INDICATES MAX. TOP

DESIGN WATER

STORAGE LEVEL FOR

1% AEP STORM

TWL

TWL

TWL

15

0

30

0

85

TWL

PERMAVOID 150 GEOCELLULAR

STORAGE OR SIMILAR

APPROVED WRAPPED IN

GEOTEXTILE

PERMAVOID 85 GEOCELLULAR

STORAGE OR SIMILAR APPROVED

WRAPPED IN GEOTEXTILE

50mm LAYING COURSE

(6mm AGGREGATE)

PERMEABLE PAVING BLOCKS

JOINTING (6mm

AGGREGATE)

45

0

STORAGE LAYER OF CLEAN CRUSHED,

WASHED, 20-50mm ANGULAR STONE

WITH POROSITY 30-40%

IMPERMEABLE MEMBRANE

PERMEABLE PAVING DETAIL (ON-PODIUM)

SECTION

PROTECTED

ORIFICE TO

CONTROL

FLOW RATE &

DESIGN HEAD

AS PER PLAN

DRAWING

OVERFLOW

WEIR

CONTROFLOW 600SERIES LEVEL INVERT

OR EQUAL APPROVEDFLOW CONTROL

CHAMBER

FLOW CONTROL

GREEN ROOF - TYPICAL SECTION

Vegetation Barrier

100mm

BAUDER GREEN ROOF

PARAPET UPSTAND

BAUDER GREEN ROOF OUTLET

ALU 250 INSPECTION CHAMBER.HEIGHT EXTENSION PIECE AVAILABLE.

Vegetation Barrier

100mm

Min

.150

mm

GREEN ROOF DESIGN BY LANDSCAPEARCHITECT OR DESIGN SPECIALIST

PERMAVOID 150 GEOCELLULAR

STORAGE OR SIMILAR

APPROVED WRAPPED IN

GEOTEXTILE

OVERFLOW

WEIR

PERMAVOID CELLULAR STORAGE,

OR SIMILAR

PODIUM SLAB

PODIUM WATERPROOFINGTO ARCHITECT DETAIL

50mm LAYING COURSE

(6mm AGGREGATE)

PERMEABLE PAVING BLOCKS

JOINTING (6mm

AGGREGATE)

45

0

STORAGE LAYER OF CLEAN CRUSHED,

WASHED, 20-50mm ANGULAR STONE

WITH POROSITY 30-40%

PERMEABLE GEOTEXTILE WITH A

MIN. 0.6m/s INFLITRATION RATE AS

PER BS EN ISO 10319:2015

INFILTRATION TO GROUNDWATER FROM

LAND DRAIN. INFILTRATION TEST TO BE

COMPLETED TO DETERMINE INFILTRATION

RATE AT EACH PROPOSED LOCATION IN

ACCORDANCE WITH BRE GUIDANCE

UNDERLYING SOIL MUST NOT BE

COMPACTED IN INFILTRATION AREAS

PERMEABLE PAVING DETAIL (OFF-PODIUM)

SECTION

PERMAVOID CELLULAR STORAGE,

OR SIMILAR

Head Office,9 Prussia Street,Dublin 7.D07 KT57

TEL +353 (0)1 8682000

e: [email protected]: www.ocsc.ie

Drn by: Aprvd by:Chkd by:

Code Status Revision

Date: Scale: @ A1

Project:

Title:

Originator Zone Type Role NumberLevel

Rev No. Date Revision Note Drn by Chkd by· FOR SETTING OUT REFER TO ARCHITECT'S DRAWINGS.· THIS DRAWING TO BE READ IN CONJUNCTION WITH ALL OTHER

ARCHITECTURAL AND ENGINEERING DRAWINGS AND ALL OTHERRELEVANT DRAWINGS AND SPECIFICATIONS.

· DO NOT SCALE THIS DRAWING. USE FIGURED DIMENSIONS ONLY.· NO PART OF THIS DOCUMENT MAY BE REPRODUCED OR TRANSMITTED

IN ANY FORM OR STORED IN ANY RETRIEVAL SYSTEM OF ANY NATUREWITHOUT THE WRITTEN PERMISSION OF O'CONNOR SUTTON CRONINAS COPYRIGHT HOLDER EXCEPT AS AGREED FOR USE ON THE PROJECTFOR WHICH THE DOCUMENT WAS ORIGINALLY ISSUED. - - -

Client:Drn by Chkd by

- - -

Dublin London Belfast Galway Cork

Rev No. Date Revision Note

ENVIRONMENT QUALITY HEALTH & SAFETY

ISO 14001:2015 ISO 9001:2015 OHSAS 18001:2007

NSAI Certified NSAI Certified NSAI Certified

BIM Verified

Design & Construction

Capital/Delivery

PAS 1192-2

bsi.

O'CONNOR SUTTON CRONIN

MultidisciplinaryConsulting Engineers

Sandyford GP Limited.Sandyford Central

SuDs Details

SFC OCSC 00 XX DR C 0510 A1 C0228.02.19 n.t.s. JB AH MMcG

P01 28.02.19 SUITABLE FOR INFORMATION JB AHP02 14.06.19 SUITABLE FOR INFORMATION JB PRC01 19.07.19 PAC SUBMISSION JS JBP03 12.11.2019 SUITABLE FOR INFORMTION MK AHC02 19.11.2019 STAGE COMPLETE - PLANNING MK PR

PLANNING DRAWING.

NOT FOR CONSTRUCTION.

ALL LEVELS GIVEN ARE

RELATIVE TO ORDNANCE DATUM.

THIS DRAWING HAS BEEN ISSUED FOR INFORMATION

PURPOSES ONLY AND MUST NOT BE USED

FOR CONSTRUCTION UNDER ANY CIRCUMSTANCES