8Network Rail Cables SpecificationSignalling . . . . . . . . . . . . NR/PS/SIG/00005 . . . . . 8:2Copper Trackside . . . . . . . NR/PS/TEL/00015 . . . . . 8:6Data Link. . . . . . . . . . . . . BR1932 . . . . . . . . . . . . . 8:9Fibre Trackside . . . . . . . . NR/PS/TEL/00014 . . . . 8:10Di-SAC Single Mode Fibre . . . . . . . . . . . . . . . . . . . 8:11Axle Counter . . . . . . . . . . NR/L2/SIG/30060 . . . . 8:12Aluminium Power. . . . . . . BR880 . . . . . . . . . . . . . 8:14Track Feeder . . . . . . . . . . NR/PS/ELP/21101 . . . . 8:16Pilot . . . . . . . . . . . . . . . . NR/PS/ELP/27220 . . . . 8:17MV Feeder . . . . . . . . . . . NR/PS/ELP/00008 . . . . 8:18Points Heating . . . . . . . . . NR/PS/ELP/40045 . . . . 8:24Screening Conductor . . . . NR/PS/TEL/31102 . . . . 8:26
Rolling Stock/Traction CablesSingle-Core Cross-Linked PolyolefinInsulated Cable . . . . . . . . . . . . . . . . . . . . . . . . . . 8:28EN 50264-2-1 Flexible Single-Core . . . . . . . . . . . . 8:32HUBER + SUHNER Radox 4 GKW-AX . . . . . . . . . . . 8:34Single-Core Equipment Wire . . . . . . . . . . . . . . . . . 8:36Single and Multicore Screened Equipment Cable . . 8:38RSE/STD/024 LFH cables for LUL . . . . . . . . . . . . . . 8:40RIA 10 - Multicore Rubber Flexible . . . . . . . . . . . . 8:42RIA 21 - Single-Core Rubber Flexibles . . . . . . . . . . 8:44
Rail Cables
Rail Cables
08•2Products. Technology. Services. Delivered Globally.
anixter.com
Rail Cables
Signalling Cables HD Elastomeric & LSZH Sheathed
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Specification
• NR/PS/SIG/00005
Construction
• Conductors: Stranded Class 2 or flexible Class 5 tinnedcopper conductors to BS EN 60228 and Table 1 ofNR/PS/SIG/00005
• Insulation: EPR insulation Type GP4 to BS7655 for TypesB1, B2, C1, C2, C3, D1, D2, E1, E2 and E3 cables. TypeA1, A2 and A3 cables will have LSZH insulation
• Core Identification:Type A1(single-core) cable - various coloursType A2, B1, C1, D1 and E1 (single-core) cables - blackType A3, B2, C2, C3, D2, E2 and E3 cables - white printednumbers on black insulationOption of red, black on two core cable only
• Screen: Type C3 and E3 cables have collective screen,featuring aluminium/p.e.t.p. tape in contact with tinnedcopper drain wire
• Outer Sheath: Black heavy duty Elastomeric Type RS2 toBS7655 for Types B1, B2, C1, C2 and C3 cables. LSZHouter sheath to NR/PS/SIG/00005 for Type A2, A3, D1, D2,E1, E2 and E3 cables
• Flame Retardant to BS EN 60332-1-2
• Voltage Rating: 650/1100 V
• Temperature Rating: 60°C maximum conductoroperating temperature (85°C for LSZH sheathed cables)
Application
Anixter signalling cables are designed for use in remote operation of trackside signalling systems.
These cables feature heavy duty Elastomeric sheaths for protection from abrasion, mechanical impact, contact with oils andgreases. Type A1, A2 and A3 cables feature a LSZH insulation, with Type A2 and A3 cables having an additional LSZH sheath.
08•3Products. Technology. Services. Delivered Globally.
anixter.com
Rail Cables
Signalling Cables HD Elastomeric & LSZH Sheathed
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
PADS CatalogueNumber
Anixter Number Cable Type Conductor NominalOuterDiameter
mm
Nominal Weight
kg/km
MinimumBendingRadiusFixed Bend
mm
Number of Cores
NominalConductorArea
mm2
Number andNominalDiameter ofStrands#/mm
6/120001 A3A1-010075-06 A1 (blue) 1 0.75 7/0.37 2.9 16 106/120002 A3A1-010075-07 A1 (brown) 1 0.75 7/0.37 2.9 16 106/120003 A3A1-010075-03 A1 (red) 1 0.75 7/0.37 2.9 16 106/120004 A3A1-010075-08 A1 (orange) 1 0.75 7/0.37 2.9 16 106/120005 A3A1-010075-09 A1 (grey) 1 0.75 7/0.37 2.9 16 106/120006 A3A1-010075-10 A1 (violet) 1 0.75 7/0.37 2.9 16 106/120007 A3A1-010075-02 A1 (black) 1 0.75 7/0.37 2.9 16 106/120008 A3A1-010115-02 A1 (black) 1 1.15 16/0.30 3.2 20 106/120020 A3A2-010075-02 A2 1 0.75 7/0.37 4.5 30 156/120024 A3A2-010115-02 A2 1 1.15 16/0.30 4.7 35 156/120040 A3A3-020075-02 A3 2 0.75 7/0.37 8.1 67 306/120041 A3A3-040075-02 A3 4 0.75 7/0.37 9.5 108 306/120042 A3A3-060075-02 A3 6 0.75 7/0.37 11.5 160 406/120043 A3A3-100075-02 A3 10 0.75 7/0.37 13.8 259 606/120044 A3A3-140075-02 A3 14 0.75 7/0.37 15.1 495 706/120045 A3A3-360075-02 A3 36 0.75 7/0.37 21.9 752 90
6/120062 A3B1-010100-02 B1 1 10 7/1.35 10.5 205 606/120063 A3B1-010350-02 B1 1 35 19/1.53 14.6 495 906/120081 A3B2-020015-02 B2 2 1.5 7/0.53 10.9 135 606/120082 A3B2-020025-02 B2 2 2.5 7/0.67 11.93 170 606/120083 A3B2-020100-02 B2 2 10 7/1.35 17.0 443 1106/120084 A3B2-020350-02 B2 2 35 19/1.53 25.8 1232 1606/120085 A3B2-020700-02 B2 2 70 19/2.14 32.8 2043 2006/120086 A3B2-020950-02 B2 2 95 19/2.52 38.1 2945 2306/120090 A3B2-070075-02 B2 7 0.75 7/0.37 13.3 240 906/120091 A3B2-070015-02 B2 7 1.5 7/0.53 14.2 300 1006/120092 A3B2-070025-02 B2 7 2.5 7/0.67 15.5 390 1006/120093 A3B2-100075-02 B2 10 0.75 7/0.37 15.6 280 1006/120094 A3B2-100015-02 B2 10 1.5 7/0.53 17.7 401 1106/120095 A3B2-100025-02 B2 10 2.5 7/0.67 19.3 560 1206/120096 A3B2-120075-02 B2 12 0.75 7/0.37 16.2 321 1006/120097 A3B2-120015-02 B2 12 1.5 7/0.53 17.3 410 1106/120098 A3B2-120025-02 B2 12 2.5 7/0.67 19.8 610 1206/120099 A3B2-190075-02 B2 19 0.75 7/0.37 17.4 425 1106/120100 A3B2-190015-02 B2 19 1.5 7/0.53 19.9 615 1206/120101 A3B2-190025-02 B2 19 2.5 7/0.67 22.0 815 1406/120102 A3B2-270075-02 B2 27 0.75 7/0.37 22.5 606 1406/120103 A3B2-270015-02 B2 27 1.5 7/0.53 24.09 897 1506/120104 A3B2-270025-02 B2 27 2.5 7/0.67 26.5 1200 1606/120105 A3B2-370075-02 B2 37 0.75 7/0.37 25.3 786 1606/120106 A3B2-370015-02 B2 37 1.5 7/0.53 27.9 1126 1706/120107 A3B2-370025-02 B2 37 2.5 7/0.67 29.8 1600 1806/120108 A3B2-480075-02 B2 48 0.75 7/0.37 28.9 972 1806/120109 A3B2-480015-02 B2 48 1.5 7/0.53 32.5 1280 2006/120110 A3B2-480025-02 B2 48 2.5 7/0.67 35.1 2010 2106/120111 A3B2-060075P-02 B2 6-pair 0.75 7/0.37 22.2 470 140
08•4Products. Technology. Services. Delivered Globally.
anixter.com
Rail Cables
Signalling CablesPADS CatalogueNumber
Anixter Number Cable Type Conductor NominalOuterDiameter
mm
Nominal Weight
kg/km
MinimumBendingRadiusFixed Bend
mm
Number of Cores
NominalConductorArea
mm2
Number andNominalDiameter ofStrands#/mm
6/120130 A3C1-010025-02 C1 1 2.5 50/0.25 11.7 174 606/120140 A3C2-020025-02 C2 2 2.5 50/0.25 16.8 342 706/120141 A3C2- 040025-02 C2 4 2.5 50/0.25 18.6 445 806/120142 A3C2-070025-02 C2 7 2.5 50/0.25 21.2 590 906/120143 A3C2-100025-02 C2 10 2.5 50/0.25 25.5 784 1106/120144 A3C2-120025-02 C2 12 2.5 50/0.25 26.2 868 1106/160086 A3C3-020025-02 C3 TPWS 1-pair 2.5 50/0.25 16.6 250 100
6/120214 A3D1-010100-02 D1 1 10 7/1.35 10.5 205 606/120215 A3D1-010350-02 D1 1 35 19/1.53 14.6 495 906/120216 A3D2-020015-02 D2 2 1.5 7/0.53 10.9 135 606/120217 A3D2-020025-02 D2 2 2.5 7/0.67 11.93 170 606/120218 A3D2-020100-02 D2 2 10 7/1.35 17.0 443 1106/120226 A3D2-020160-02 D2 2 16 7/1.70 18.8 630 1206/120219 A3D2-020350-02 D2 2 35 19/1.53 25.8 1232 1606/120220 A3D2-020700-02 D2 2 70 19/2.14 32.8 2043 2006/120221 A3D2-020950-02 D2 2 95 19/2.52 38.1 2945 2306/120230 A3D2-100075-02 D2 10 0.75 7/0.37 15.6 280 1006/120231 A3D2-100015-02 D2 10 1.5 7/0.53 17.7 401 1106/120233 A3D2-120075-02 D2 12 0.75 7/0.37 16.2 321 1006/120234 A3D2-120015-02 D2 12 1.5 7/0.53 17.3 410 1106/120236 A3D2-190075-02 D2 19 0.75 7/0.37 17.4 425 1106/120237 A3D2-190015-02 D2 19 1.5 7/0.53 19.9 615 1206/120210 A3D2-190025-02 D2 19 2.5 7/0.67 22.0 815 1406/120238 A3D2-270075-02 D2 27 0.75 7/0.37 22.5 606 1406/120239 A3D2-270015-02 D2 27 1.5 7/0.53 24.09 897 1506/120240 A3D2-270025-02 D2 27 2.5 7/0.67 26.5 1200 1606/120241 A3D2-370075-02 D2 37 0.75 7/0.37 25.3 786 1606/120242 A3D2-370015-02 D2 37 1.5 7/0.53 27.9 1126 1706/120243 A3D2-370025-02 D2 37 2.5 7/0.67 29.8 1600 1806/120244 A3D2-480075-02 D2 48 0.75 7/0.37 28.9 972 1806/120245 A3D2-480015-02 D2 48 1.5 7/0.53 32.5 1280 200
6/120172 A3E1-010025-02 E1 1 2.5 50/0.25 11.7 174 606/120170 A3E2-020025-02 E2 2 2.5 50/0.25 16.8 342 706/120171 A3E2- 040025-02 E2 4 2.5 50/0.25 18.6 445 806/120173 A3E2-070025-02 E2 7 2.5 50/0.25 21.2 590 906/120174 A3E2-100025-02 E2 10 2.5 50/0.25 25.5 784 1106/120175 A3E2-120025-02 E2 12 2.5 50/0.25 26.2 868 1106/160090 A3E3-020025-02 E3 TPWS 1-pair 2.5 50/0.25 16.6 250 100
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
08•5Products. Technology. Services. Delivered Globally.
anixter.com
Nominal Conductor Areamm2
Cable Type Maximum d.c. ConductorResistance @ 20 ohms/km
Minimum Insulation Resistanceper km of Cable (MegOhms)
0.75 A1/A2/A3 24.8 4001.15 A1/A2/A3 17.3 3500.75 B1/B2/D1/D2 24.8 9001.5 B1/B2/D1/D2 12.2 7002.5 B1/B2/D1/D2 7.56 55010.0 B1/B2/D1/D2 1.84 40035 B1/B2/D1/D2 1.16 25070 B2/D2 0.270 20095 B2/D2 0.195 2002.5 C1/C2/C3 8.21 6502.5 E1/E2/E3 8.21 650
Rail Cables
Signalling Cables - Technical Information
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
08•6
Rail Cables
Copper Trackside Communication Cable
Specification
• NR/PS/TEL/00015
Application
This range of cables is designed primarily for trackside railway installation.
Construction
UnarmouredThese twisted pair cables consist of solid plain copper conductors of either 0.63mm or 0.9mm in diameter. The conductors aresolid polyethylene insulated and two insulated conductors are twisted to form a pair*. The required number of pairs are laid upand petroleum jelly filled. Covering this are layers of: water swellable tape, paper core wrap and a black low-densitypolyethylene sheath. The cable incorporates a longitudinally applied aluminium/polyethylene moisture barrier, and is availablewith either a polyethylene or ZHLS sheath.
*Two-pair cables are laid up in quad formation.
ArmouredThe construction and pair formation are as above, but with the addition of rodent protection in the form of corrugated steel armour.
Products. Technology. Services. Delivered Globally.
anixter.com
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
08•7Products. Technology. Services. Delivered Globally.
anixter.com
Rail Cables
Copper Trackside Communication Cable
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
PADSCatalogue Number
Anixter Number Conductor Diameter Number of Pairs Nominal OuterDiameter mm
Nominal Weight
kg/km
Polyethylene Sheathed - Armoured
6/168061 A11AW-P002S-02FTN 1/0.9 2 19.0 250
6/168062 A11AW-P005S-02FTN 1/0.9 5 21.3 365
6/168063 A11AW-P010S-02FTN 1/0.9 10 23.8 520
6/168064 A11AW-P020S-02FTN 1/0.9 20 27.6 820
6/168065 A11AW-P030S-02FTN 1/0.9 30 30.9 1060
6/168066 A11AW-P050S-02FTN 1/0.9 50 35.7 1550
6/168067 A11AW-P075S-02FTN 1/0.9 75 38.8 1912
6/168068 A11AW-P100S-02FTN 1/0.9 100 44 2450
6/168011 A11AV-P002S-02FTN 1/0.63 2 18.0 205
6/168012 A11AV-P005S-02FTN 1/0.63 5 19.5 285
6/168013 A11AV-P010S-02FTN 1/0.63 10 21.3 380
6/168014 A11AV-P020S-02FTN 1/0.63 20 23.8 550
6/168015 A11AV-P030S-02FTN 1/0.63 30 26.1 690
6/168016 A11AV-P050S-02FTN 1/0.63 50 29.9 960
6/168017 A11AV-P075S-02FTN 1/0.63 75 31.5 1147
6/168018 A11AV-P100S-02FTN 1/0.63 100 35.4 1464
Polyethylene Sheathed - Unarmoured
6/168051 A11AW-P002-02FTN 1/0.9 2 11.5 95
6/168052 A11AW-P005-02FTN 1/0.9 5 13.8 180
6/168053 A11AW-P010-02FTN 1/0.9 10 16.3 246
6/168054 A11AW-P020-02FTN 1/0.9 20 20.1 545
6/168055 A11AW-P030-02FTN 1/0.9 30 23.4 750
6/168056 A11AW-P050-02FTN 1/0.9 50 28.2 1175
6/168057 A11AW-P075-02FTN 1/0.9 75 33.6 1541
6/168058 A11AW-P100-02FTN 1/0.9 100 38.8 2051
6/168001 A11AV-P002-02FTN 1/0.63 2 10.5 71
6/168002 A11AV-P005-02FTN 1/0.63 5 12.0 120
6/168003 A11AV-P010-02FTN 1/0.63 10 13.8 190
6/168004 A11AV-P020-02FTN 1/0.63 20 16.3 325
6/168005 A11AV-P030-02FTN 1/0.63 30 18.6 435
6/168006 A11AV-P050-02FTN 1/0.63 50 22.4 660
6/168007 A11AV-P175-02FTN 1/0.63 75 26.4 930
6/168008 A11AV-P100-02FTN 1/0.63 100 29.2 1230
08•8Products. Technology. Services. Delivered Globally.
anixter.com
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
PADS Catalogue Number
Anixter Number Conductor Diameter Number of Pairs Nominal OuterDiameter mm
Nominal Weight
kg/km
ZHLS Sheathed - Armoured
6/168081 A11BT-P002S-02FTN 1/0.9 2 21.3 380
6/168082 A11BT-P005S-02FTN 1/0.9 5 23.1 550
6/168083 A11BT-P010S-02FTN 1/0.9 10 26.1 700
6/168084 A11BT-P020S-02FTN 1/0.9 20 29.9 1000
6/168085 A11BT-P030S-02FTN 1/0.9 30 33.2 1240
6/168086 A11BT-P050S-02FTN 1/0.9 50 38.0 1720
6/168088 A11BT-P100S-02FTN 1/0.9 100 46.6 2780
6/168031 A11BS-P002S-02FTN 1/0.63 2 21.3 380
6/168032 A11BS-P005S-02FTN 1/0.63 5 21.3 425
6/168033 A11BS-P010S-02FTN 1/0.63 10 21.8 550
6/168034 A11BS-P020S-02FTN 1/0.63 20 26.1 740
6/168035 A11BS-P030S-02FTN 1/0.63 30 28.4 880
6/168036 A11BS-P050S-02FTN 1/0.63 50 32.2 1150
6/168038 A11BS-P100S-02FTN 1/0.63 100 38.5 1760
ZHLS Sheathed - Unarmoured
6/168071 A11BT-P002-02FTN 1/0.9 2 13.3 130
6/168072 A11BT-P005-02FTN 1/0.9 5 15.6 219
6/168073 A11BT-P010-02FTN 1/0.9 10 18.1 329
6/168074 A11BT-P020-02FTN 1/0.9 20 21.9 520
6/168075 A11BT-P030-02FTN 1/0.9 30 25.2 702
6/168076 A11BT-P050-02FTN 1/0.9 50 30.0 1065
6/168078 A11BT-P100-02FTN 1/0.9 100 39.1 1890
6/168021 A11BS-P002-02FTN 1/0.63 2 12.3 103
6/168022 A11BS-P005-02FTN 1/0.63 5 13.8 158
6/168023 A11BS-P010-02FTN 1/0.63 10 15.6 226
6/168024 A11BS-P020-02FTN 1/0.63 20 18.1 332
6/168025 A11BS-P030-02FTN 1/0.63 30 20.4 420
6/168026 A11BS-P050-02FTN 1/0.63 50 24.2 618
6/168028 A11BS-P100-02FTN 1/0.63 100 31.0 1090
Rail Cables
Copper Trackside Communication Cable
08•9Products. Technology. Services. Delivered Globally.
anixter.com
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Rail Cables
Data Link Cable
Application
Twin data link cable is rated for outdoor use and employs solid conductors with polyethylene insulation and sheath for use onrailway signalling.
Construction
• Conductors: Solid plain annealed copper to BS EN 60228and Table 1 of BR1932
• Insulation: Polyethylene insulation Type 03 to BS6234
• Lay-Up & Core Identification: Two cores (red, blue)twisted together with a nominal lay length of 150mm
• Polyethylene Belt: Polyethylene sheath Type 03 or Type 2to BS6234. (0.7mm radial thickness)
• Moisture Barrier: Longitudinally applied polyethylenebacked 0.15mm aluminium tape bonded to:-
• Outer Sheath: Black or blue polyethylene outer sheathType 03 (blue) and Type 03C (black) to BS6234
• Temperature Rating: 70°C maximum conductoroperating temperature
• Voltage Rating: 300 V
Specification
• BR 1932
Technical Information
Max. d.c. conductor resistance @ 20°C - 14.0 ohms/kmNom. mutual capacitance @ 10 kHz - 55 pF/m (+/- 5.5 pF)Nom. characteristic impedance @ 10 MHz - 100 ohms (+/- 10 ohms)Min. insulation resistance @ 500 V d.c. - 40 G ohms/km
PADSNumber
AnixterCat. Number
Number ofCores
NominalConductorArea
NominalConductorStranding
InsulationThickness
SheathThickness
Sheath Colour
NominalO/D
ApproxCable Weight
Minimum Bending Radius
mm2 #/mm mm mm mm kg/km mm
6/166065 541766 2 1.27 1/1.27 0.6 2.5* Black 12.5 150 130
- 323079 2 1.27 1/1.27 0.6 2.5* Blue 12.5 150 130
* Including moisture barrier.
08•10Products. Technology. Services. Delivered Globally.
anixter.com
Rail Cables1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Fibre Trackside
Construction
Unarmoured TS1837, TS1927These cables consist of singlemode 250µm buffered fibres, arranged in stranded loose tube construction around a centralnon-metallic strength member, with fillers where required. Covering this are layers of water swellable tape, steel polymerlaminate tape and a polyethylene or LSZH sheath.
Armoured TS1837, TS1927The construction is as above, but with the addition of a corrugated steel polymer laminate tape armour, polyethylene or LSZH sheath.
Part numbers shown are for polyethylene sheathed cables. For LSZH cables, PE is replaced by LS in the part number e.g. 370-304-8LS2-12. Other sizes are available on request.Anixter also stock a complete range of fibre optic accessories, termination and test equipment including - internal and externalenclosures, connectors, adaptors, pigtails, patch cables, tool kits, fusion splicers and OTDR’s. More details are available on request.
Anixter Number Construction Fibre Count
370-304-8PE2-12 Unarmoured 12
370-304-8PE2-20 20
370-304-8PE2-24 24
370-304-8PE2-48 48
370-304-8PE2-96 96
370-305-8PE2-12 Armoured 12
370-305-8PE2-20 20
370-305-8PE2-24 24
370-305-8PE2-48 48
370-305-8PE2-96 96
Specification
•NR/PS/TEL/00014
Application
Anixter fibre optic cables are designed for use in trackside telecommunications, data and CCTV systems, which include directburial and duct applications as well as rodent protection and fire performance requirements.
08•11Products. Technology. Services. Delivered Globally.
anixter.com
Rail Cables1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Fibre - Single Mode Di-SAC
Application
A very robust fibre cable. Suitable for being laid direct onto the ballast or buried direct.Does not require a concrete trough or other expensive protection.
Construction
• Loose Steel Tube
• Aluminium Spacer
• MDPE Insulation
• Steel Wire Armour
• Flooding
• Green ZHLS Jacket
• Fibre Colour Code 1. Blue, 2. Orange, 3. Green, 4. Brown5.Grey, 6. White, 7. Red, 8.Black, 9. Yellow, 10. Violet11.Pink, 12. Aqua
Tube identification - One tube is coloured by white ink,another coloured by red ink.
Specification
Designed specifically for Network Rail to PADS number 6/169083.
Anixter Number Construction Fibre Size Fibre Count Nominal Diameter
mm
Minimum BendingRadius (Fixed Bend)mm
Nominal Weight
kg/km
372-SAM-9-LTALSZH-24 Armoured 9/125 24 18 270 815
Tensile Strength: 20,000NCrush: 35,000NImpact: 120J
08•12Products. Technology. Services. Delivered Globally.
anixter.com
Rail Cables 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Axle Counter Cable
Specifications
•NR/L2/SIG/30060
Application
For use with axle counter train detection systems.
Construction
• Conductor: Solid tinned annealed copper to BS EN 60228
• Insulation: Polyethylene
• Filler: Petroleum Jelly
• Anti-Rodent Protection: Glass-fibre weave
• Moisture Barrier: Aluminium/Copolymer Laminated Tape
• Sheath: Polyethylene or ZHLS. Black
08•13Products. Technology. Services. Delivered Globally.
anixter.com
Rail Cables 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Axle Counter Cable
PADS CatalogueNumber
Anixter Number
ConductorDiameter
Number ofPairs/Quads
Cable Type Nominal OuterDiameter mm
Sheath Nominal Weight kg/km
Polyethylene Sheathed
6/170007 AXLE-PE-0.9-P002 1/0.9 2PR XPS 15.1 PE 190
6/170008 AXLE-PE-0.9-P010 1/0.9 10PR XPS 21.4 PE 435
6/170009 AXLE-PE-0.9-P012 1/0.9 12PR XPS 22.2 PE 490
6/170034 AXLE-PE-0.9-P019 1/0.9 19PR XPS 25.9 PE 685
6/170035 AXLE-PE-0.9-P024 1/0.9 24PR XPS 28.1 PE 815
6/170021 AXLE-PE-0.9-Q1 1/0.9 1 Quad XQS 11.2 PE 180
6/170036 AXLE-PE-1.4-P002 1/1.4 2PR XPS 16.9 PE 305
6/170037 AXLE-PE-1.4-P010 1/1.4 10PR XPS 24.6 PE 815
6/170038 AXLE-PE-1.4-P012 1/1.4 12PR XPS 25.6 PE 915
6/170039 AXLE-PE-1.4-P019 1/1.4 19PR XPS 30.1 PE 1330
6/170040 AXLE-PE-1.4-P024 1/1.4 24PR XPS 32.8 PE 1620
6/170050 AXLE-PE-1.4-Q1 1/1.4 1 Quad XQS 13.4 PE 295
ZHLS Sheathed
6/170023 AXLE-ZHLS-0.9-P002 1/0.9 2PR XPZ 15.1 ZHLS 260
6/170024 AXLE-ZHLS-0.9-P010 1/0.9 10PR XPZ 21.4 ZHLS 530
6/170025 AXLE-ZHLS-0.9-P012 1/0.9 12PR XPZ 22.2 ZHLS 590
6/170026 AXLE-ZHLS-0.9-P019 1/0.9 19PR XPZ 25.9 ZHLS 805
6/170027 AXLE-ZHLS-0.9-P024 1/0.9 24PR XPZ 28.0 ZHLS 950
6/170053 AXLE-ZHLS-0.9-Q1 1/0.9 1 Quad XQZ 11.2 ZHLS 250
6/170028 AXLE-ZHLS-1.4-P002 1/1.4 2PR XPZ 16.8 ZHLS 390
6/170029 AXLE-ZHLS-1.4-P010 1/1.4 10PR XPZ 24.6 ZHLS 950
6/170030 AXLE-ZHLS-1.4-P012 1/1.4 12PR XPZ 25.6 ZHLS 1055
6/170031 AXLE-ZHLS-1.4-P019 1/1.4 19PR XPZ 30.1 ZHLS 1500
6/170032 AXLE-ZHLS-1.4-P024 1/1.4 24PR XPZ 32.8 ZHLS 1820
6/170033 AXLE-ZHLS-1.4-Q1 1/1.4 1 Quad XQZ 13.5 ZHLS 380
08•14Products. Technology. Services. Delivered Globally.
anixter.com
Rail Cables 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Specifications
•BR880
Construction
• Conductor: Solid sector shaped aluminium to BS EN 60228 and Table 2 of BS5467
• Insulation: XLPE insulation Type GP8 to BS7655
• Core Identification:2 core - brown, blue4 core - brown, black, grey, blue
• Outer Sheath: Black PVC outer sheath Type 9 to BS7655
• Flame retardant to BS EN 60332-1-2
• Temperature Rating: 90°C maximum conductoroperating temperature
• Voltage Rating: 600/1000 V
Aluminium Power Cable - XLPE/PVC
PADS CatalogueNumber
AnixterNumber
Number ofCores
Nominal ConductorAreamm2
InsulationThickness
mm
Nominal O/D
mm
Approx. CableWeight
kg/km
MinimumBending Radius
mm
6/142419 BR880-2C-0160 2 16* 0.7 14.4 420 120
6/142519 BR880-2C-0250 2 25 * 0.9 15.3 455 130
6/142609 BR880-2C-0350 2 35 0.9 16.7 525 140
6/142629 BR880-2C-0500 2 50 1.0 18.7 620 150
6/142639 BR880-2C-0700 2 70 1.1 21.3 840 180
6/142644 BR880-2C-0950 2 95 1.1 23.8 1020 200
6/151469 BR880-4C-0700 4 70 1.1 29.1 1750 240
6/151494 BR880-4C-0950 4 95 1.1 32.8 2100 270
* May also be supplied with stranded circular aluminium conductors, which may increase diameter and weight.
Application
For trackside signalling power applications, incorporating solid aluminium conductors.
08•15Products. Technology. Services. Delivered Globally.
anixter.com
Rail Cables1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Technical InformationMulticore XLPE/PVC 600/1000 V Aluminium Power Cables to BR880
Electrical Characteristics
Conductor Size
mm2
Maximum d.c. Conductor Resistance @ 20ºCohms/km
Maximum a.c. Conductor Resistance @ 90ºCohms/km
Reactance @ 50 Hz
ohms/km
Impedance @ 90ºC, 50 Hzohms/km
16 1.91 2.45 0.079 2.45
25 1.20 1.54 0.080 1.54
35 0.868 1.11 0.077 1.11
50 0.641 0.822 0.076 0.826
70 0.443 0.568 0.075 0.573
95 0.320 0.411 0.073 0.417
Nominal Conductor Area
mm2
2 Core - Single Phasea.c.mV
d.c.mV
4 Core - Three Phase a.c.
mV
16 4.9 4.9 4.2
25 3.1 3.1 2.67
35 2.2 2.2 1.92
50 1.65 1.64 1.43
70 1.15 1.13 0.99
95 0.83 0.84 0.72
Voltage Drop (per Ampere per metre)
Nominal Conductor Areamm2
Air2 Core 4 Core
16 93 81
25 116 101
35 142 124
50 172 151
70 219 192
95 270 237
Current Carrying Capacity (Amperes)
Conductor operating temperature 90°C.Ambient air temperature 25°C.
If cables are to be used in ambient air temperatures other than 25°C the following factors should be applied:
Ambient air temp °C 10 15 20 25 30 35 40 45 50 55Rating factor 1.11 1.07 1.04 1.0 0.96 0.92 0.88 0.83 0.78 0.73
08•16Products. Technology. Services. Delivered Globally.
anixter.com
Rail Cables 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Application
For use on d.c. traction systems to provide, the 650/750 V d.c. supply from traction substations and track paralleling huts tothe conductor rails and negative cable connections and, where appropriate, bonding.
Positive cables provide the connections between the positive d.c. switchgear and isolators and lineside equipment associatedwith the electrification system. This may include, conductor rails and between lengths of conductor rail.
Negative connections are installed at substations and track paralleling huts between the negative bar and electric trackequipment installed on the track. This may include impedance bonds, resonating bonds or terminating plates, running rails,negative conductor rails, reinforcing rails or running rails.
Track Feeder Cables
Construction
• Conductors: Class 2 standard aluminium or stranded copper
• Separation: P.E.T.P.
• Sheath: Black CSP (Chlorosulphonated polyethylene)
• Temperature: -25°C to +85°C
• Voltage: 650/750 V
PADS Number Anixter Cat. Stranding
d.c.Application
NominalOuterDiametermm
Nominal Weight
Kg/km
Number NominalAreamm2
Material
6/116601 TF-ALUM-150 150 Aluminium 37/2.25 Negative 19.4 600
6/132340 TF-COPPER-161 161 Copper 91/1.53 Negative 24.8 2000
6/132990 TF-ALUM-240 240 Aluminium 61/2.25 Negative 28.3 1200
6/132840 TF-ALUM-500 500 Aluminium 61/3.20 Positive 40.2 2300
6/132992 TF-COPPER-500 500 Copper 91/2.65 Negative 40.6 5600
6/116612 TF-COPPER-630 630 Copper 127/2.52 Positive 44.2 7000
6/132991 TF-ALUM-800 800 Aluminium 127/2.85 Negative 48.5 3400
6/116610 TF-ALUM-1000 1000 Aluminium 127/3.00 Positive 53.0 4200
Conductor
Specification
• NR/PS/ELP/21101
08•17Products. Technology. Services. Delivered Globally.
anixter.com
Rail Cables
Application
Paired core compound filled supervisory cables for modem based supervisory systems operating in the VF range 300 to 3000 Hz.
Construction
• Conductors: Solid plain Copper
• Insulation: Polyethylene
• Filler: Petroleum jelly
• Moisture Barrier: Polyethylene/Aluminium laminate
• Inner Sheath: Black Polyethylene
• Screen: Aluminium wires
• Outer Sheath: Black medium density Polyethylene
PADS Number Anixter Cat. Number Conductor Diameter Number of Pairs Nominal OuterDiametermm
Nominal Weight
Kg/km
6/122516 PILOT-P020-PE 1/0.9 20 27.8 946
6/120031 PILOT-P030-PE 1/0.9 30 31.8 1225
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Pilot Cable
Specification
• NR/PS/ELP/27220
08•18Products. Technology. Services. Delivered Globally.
anixter.com
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Rail Cables
MV Feeder Cable
Construction
• In accordance with NR/PS/ELP/00008 and BS6622
• Conductors: Stranded Class 2 copper or Solid Class 1aluminium conductors to BS EN 60228. Strandedaluminium conductors are also available if required
• Extruded semi-conducting layer
• Insulation: XLPE insulation
• Extruded semi-conducting layer
• Concentric screen of copper wires applied helically overextruded semi-conducting layer with water blocking tapeapplied directly under screen wires. Copper equalisingtape applied directly over screen wires
• Outer Sheath: MDPE outer sheath Type TS2 to BS7655 orLSZH sheath Type LTS1 to BS7655 with graphite coating
• Flame retardant to BS EN 60332-1-2 (LSZH sheath only)
• Temperature Rating: 90°C maximum conductoroperating temperature
• Voltage Rating: 19000/33000 V or 25000/44000 V
Application
These single-core non-armoured power cables are used in to provide three-phase power at nominal system voltages of 33kV or44 kV to traction substations on d.c. electrified lines.
Specification
•NR/PS/ELP/00008
08•19Products. Technology. Services. Delivered Globally.
anixter.com
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
PADS Catalogue Number
Anixter Number ConductorMaterial
Nominal ConductorAreamm2
VoltageCategory
kV
Insulation Thickness
mm
NominalScreen Area
mm2
Sheath Material
NominalO/D
mm
ApproxWeight
kg/km
MinimumBendingRadiusmm
Aluminium MDPE
6/148032 AL-33KV-185-PE Aluminium 185 33 8.0 50 MDPE 46.5 2000 860
6/122514 AL-33KV-185-PE-0.9 Aluminium 185 33 8.0 50 MDPE 45.4 2000 860
6/122515 AL-33KV-185-PE-1.2 Aluminium 185 33 8.0 50 MDPE 45.4 2000 860
6/122517 AL-33KV-240-PE-0.9 Aluminium 240 33 8.0 50 MDPE 48.0 2300 900
Aluminium LSZH
6/148034 AL-33KV-240-ZH Aluminium 240 33 8.0 50 LSZH 50.0 2400 900
Copper MDPE
6/148023 CU-44KV-185-PE Copper 185 44 12.0 83 MDPE 47.5 3900 1120
6/148033 CU-33KV-300-PE Copper 300 33 8.0 50 MDPE 48.5 4300 970
6/122511 CU-33KV-300-PE-0.9 Copper 300 33 8.0 50 MDPE 48.5 4300 970
6/122512 CU-33KV-300-PE-1.35 Copper 300 33 8.0 50 MDPE 48.5 4300 970
6/148030 CU-44KV-400-PE Copper 400 44 12.0 83 MDPE 63.5 6400 1270
6/148024 CU-44KV-630-PE Copper 630 44 12.0 83 MDPE 71.0 9100 1420
6/148025 CU-44KV-800-PE Copper 800 44 12.0 83 MDPE 75.0 11100 1500
Copper LSZH
6/148026 CU-44KV-185-ZH Copper 185 44 12.0 95 LSZH 58.0 4700 1160
6/148027 CU-44KV-400-ZH Copper 400 44 12.0 95 LSZH 65.5 6900 1310
6/148028 CU-44KV-630-ZH Copper 630 44 12.0 95 LSZH 72.5 9600 1450
6/148029 CU-44KV-800-ZH Copper 800 44 12.0 95 LSZH 77.0 11600 1450
Rail Cables
MV Feeder Cable
The strand size of the screen can vary between manufacturers and PADS numbers.
08•20Products. Technology. Services. Delivered Globally.
anixter.com
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Rail Cables
Technical Information
• Single-Core cables to NR/PS/ELP/00008 for a.c. or d.c electrified lines
N.B. High voltage cables are not specifically covered in IEE Wiring Regulations but reference should be made to ensure compliance.
For ambient air and ground temperatures other than those specified, the following factors should be applied.
• Standard depth of laying 0.8m (to centre of cable or duct group)
• Thermal resistivity of soil 1.2°C m/W
• Standard ground temperature 15°C
• Ambient air temperature 25°C
• Maximum conductor temperature 90°C
Single phase ratings are based on following cable configurations:
Cables laid in air and in ground - Two cables with axial spacing of 2 x cable diameters Cables laid in ducts - One cable per duct, with axial spacing of 2 x duct diameters
Three phase ratings are based on following cable configurations:
Cables laid in air and in ground - Cables laid in trefoil formation
Cables laid in ducts - One cable per duct, with ducts arranged in trefoil formation (ratings are also available for 3 x cables in a single duct)
Cables laid in air
Ambient air temp °C 25 30 35 40 45 50 55 Rating factor 1.0 0.96 0.92 0.88 0.83 0.78 0.73
Cables laid in ground and in ducts
Ground temp °C 10 15 20 25 30 35 40Rating factor 1.03 1.0 0.97 0.93 0.89 0.86 0.82
08•21Products. Technology. Services. Delivered Globally.
anixter.com
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Rail Cables
Technical Information
• Single-Core cables to NR/PS/ELP/00008 for a.c. or d.c electrified lines• Single phase current ratings - 19000/33000 V cables
• Three phase current ratings - 19000/33000 V cables
NominalConductorAreamm2
ScreenAreamm2
Rating
A
NominalConductorAreamm2
ScreenAreamm2
Rating
A
NominalConductorAreamm2
ScreenAreamm2
Rating
A
185 50 - 185 50 - 185 50 -240 50 - 240 50 - 240 50 -300 50 - 300 50 - 300 50 -
Sustained Current Rating (amperes) - ALUMINIUM CONDUCTORS
Direct Burial
2 Cables 2 Cables
In Ducts In Free Air
2 Cables
NominalConductorAreamm2
ScreenAreamm2
Rating
A
NominalConductorAreamm2
ScreenAreamm2
Rating
A
NominalConductorAreamm2
ScreenAreamm2
Rating
A
150 50 315 150 50 290 150 50 380185 50 355 185 50 325 185 50 435240 50 410 240 50 375 240 50 510300 50 460 300 50 420 300 50 585
Sustained Current Rating (amperes) - ALUMINIUM CONDUCTORS
Direct Burial
3 Cables (Trefoil) 3 Cables
In Trefoil Ducts In Free Air
3 Cables (Trefoil)
NominalConductorAreamm2
ScreenAreamm2
Rating
A
NominalConductorAreamm2
ScreenAreamm2
Rating
A
NominalConductorAreamm2
ScreenAreamm2
Rating
A
150 50 405 150 50 370 150 50 495185 50 455 185 50 410 185 50 565300 50 590 300 50 520 300 50 755
Sustained Current Rating (amperes) - COPPER CONDUCTORS
Direct Burial
2 Cables 2 Cables
In Ducts In Free Air
2 Cables
NominalConductorAreamm2
ScreenAreamm2
Rating
A
NominalConductorAreamm2
ScreenAreamm2
Rating
A
NominalConductorAreamm2
ScreenAreamm2
Rating
A
150 50 405 150 50 370 150 50 495185 50 455 185 50 410 185 50 565300 50 590 300 50 520 300 50 755
Sustained Current Rating (amperes) - COPPER CONDUCTORS
Direct Burial
3 Cables (Trefoil) 3 Cables
In Trefoil Ducts In Free Air
3 Cables (Trefoil)
08•22Products. Technology. Services. Delivered Globally.
anixter.com
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Rail Cables
Technical Information
• Single-Core cables to NR/PS/ELP/00008 for a.c. or d.c electrified lines• Single phase current ratings - 25000/44000 V cables
NominalConductorAreamm2
ScreenAreamm2
Rating
A
NominalConductorAreamm2
ScreenAreamm2
Rating
A
NominalConductorAreamm2
ScreenAreamm2
Rating
A
150 50 460 150 50 400 150 50 560185 50 515 185 50 445 185 50 640240 50 590 240 50 500 240 50 745300 50 660 300 50 555 300 50 845
Sustained Current Rating (amperes) - COPPER CONDUCTORS
Direct Burial
2 Cables 2 Cables
In Ducts In Free Air
2 Cables
• Three phase current ratings - 25000/44000 V cables
NominalConductorAreamm2
ScreenAreamm2
Rating
A
NominalConductorAreamm2
ScreenAreamm2
Rating
A
NominalConductorAreamm2
ScreenAreamm2
Rating
A
185 50 455 185 50 515 185 50 630185 83 445 185 83 505 185 83 630185 95 440 185 95 495 185 95 615240 50 590 240 50 520 240 50 730240 83 575 240 83 505 240 83 730240 95 565 240 95 495 240 95 710300 50 660 300 50 580 300 50 830300 83 640 300 83 560 300 83 830300 95 625 300 95 550 300 95 800400 50 740 400 50 650 400 50 955400 83 710 400 83 620 400 83 945400 95 695 400 95 610 400 95 915500 50 825 500 50 725 500 50 1095500 83 785 500 83 690 500 83 1075500 95 765 500 95 670 500 95 1035630 50 920 630 50 805 630 50 1250630 83 865 630 83 755 630 83 1215630 95 840 630 95 735 630 95 1165800 50 1010 800 50 885 800 50 1405800 83 940 800 83 815 800 83 1360800 95 910 800 95 790 800 95 1295
Sustained Current Rating (amperes) - COPPER CONDUCTORS
Direct Burial
3 Cables (Trefoil) 3 Cables
In Trefoil Ducts In Free Air
3 Cables
‘-‘= Information not available
08•23Products. Technology. Services. Delivered Globally.
anixter.com
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Rail Cables
Technical Information
ConductorSize
mm2
ConductorType
ScreenSize
mm2
Max. d.c.ScreenResistance @20ºCohms/km
Max. d.c.ConductorResistance @20ºCohms/km
Max. a.c.ConductorResistance @90ºCohms/km
Reactance@ 50 Hz
ohms/km
Impedance @90ºC, 50 Hz
ohms/km
150 Aluminium 50 0.379 0.206 0.265 0.129 0.295185 Aluminium 50 0.379 0.164 0.211 0.124 0.245240 Aluminium 50 0.379 0.125 0.161 0.119 0.200300 Aluminium 50 0.379 0.100 0.130 0.115 0.174150 Copper 50 0.379 0.124 0.159 0.127 0.204185 Copper 50 0.379 0.0991 0.128 0.122 0.177240 Copper 50 0.379 0.0754 0.098 0.118 0.153300 Copper 50 0.379 0.0601 0.080 0.114 0.139
Sustained Current Rating (amperes) - COPPER CONDUCTORS
ConductorSize
mm2
ConductorType
ScreenSize
mm2
Max. d.c.ScreenResistance @20ºCohms/km
Max. d.c.ConductorResistance @20ºCohms/km
Max. a.c.ConductorResistance @90ºCohms/km
Reactance@ 50 Hz
ohms/km
Impedance @90ºC, 50 Hz
ohms/km
150 Copper 50 0.379 0.124 0.159 0.143 0.214185 Copper 50 0.379 0.0991 0.128 0.122 0.177185 Copper 83 0.228 0.0991 0.127 0.182 0.222185 Copper 95 0.200 0.0991 0.127 0.184 0.223240 Copper 50 0.379 0.0754 0.0980 0.177 0.202240 Copper 83 0.228 0.0754 0.0971 0.176 0.201240 Copper 95 0.200 0.0754 0.0970 0.178 0.203300 Copper 50 0.379 0.0601 0.0778 0.172 0.189300 Copper 83 0.228 0.0601 0.0778 0.171 0.188300 Copper 95 0.200 0.0601 0.0778 0.173 0.190400 Copper 50 0.379 0.0470 0.0614 0.166 0.177400 Copper 83 0.228 0.0470 0.0614 0.165 0.176400 Copper 95 0.200 0.0470 0.0614 0.167 0.178500 Copper 50 0.379 0.0366 0.0486 0.161 0.168500 Copper 83 0.228 0.0366 0.0486 0.160 0.167500 Copper 95 0.200 0.0366 0.0486 0.162 0.169630 Copper 50 0.379 0.0283 0.0386 0.156 0.161630 Copper 83 0.228 0.0283 0.0386 0.155 0.160630 Copper 95 0.200 0.0283 0.0385 0.167 0.161800 Copper 50 0.379 0.0221 0.0313 0.151 0.155800 Copper 83 0.228 0.0221 0.0313 0.151 0.154800 Copper 95 0.200 0.0221 0.0313 0.152 0.155
ELECTRICAL CHARACTERISTICS - 25000/44000 V
08•24Products. Technology. Services. Delivered Globally.
anixter.com
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Rail Cables
Specifications
• Standard: NR/SP/ELP/40045
Points Heating Cables
PADS(BR)CatalogueNumber
AnixterNumber
Conductor Minimum/MaximumOuterDiameter
mm
NominalWeight
kg/km
MinimumBendingRadiusFixed Bend
mm
Thickness ofInsulation
mm
ThicknessofSheath
mm
Number ofCores
No. andNominalDiameterof Strands#/mm
Nominal ConductorArea
mm2
6/150002 POINTS-4C-0015 4 30/0.25 1.5 13.82/14.32 220 60 0.8 2.8
- POINTS-4C-0040 4 56/0.3 4.0 17.10/17.80 420 70 1.0 2.8
6/153102 POINTS-8C-0015 8 30/0.25 1.5 17.94/18.44 460 80 0.8 2.8
6/153103 POINTS-8C-0040 8 56/0.3 4.0 22.86/23.36 830 100 1.0 2.8
Construction
• Conductors: Flexible Class 5 tinned copper conductorsto BS EN 60228
• Insulation: EPR insulation Type GP4 to BS7655
• Core Identification:4 core (in order of rotation) - yellow, yellow, blue, blue8 core (in order of rotation) - yellow, yellow, blue, blue,brown, brown, black, black
• Outer Sheath: Black PCP Type EM2 to BS7655
• Flame Retardant to BS EN 60332-1-2
• Voltage Rating: 300/500 V
• Temperature Rating: 60°C maximum conductor operating temperature
Application
This range of Anixter cables are used to feed remote strip heaters used in points heating systems.
These cables feature heavy duty PCP sheaths for protection from abrasion, mechanical impact, contact with oils and greases.
08•25Products. Technology. Services. Delivered Globally.
anixter.com
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Rail Cables • Points Heating Cables and Accessories
Technical InformationNominal Conductor Areamm2
Maximum d.c. Conductor Resistance @ 20ºCohms/km
Current Rating Single Phasea.c./d.c.A
Voltage Drop Single Phasea.c./d.c.mV/A/m
1.5 13.7 16 324 5.09 32 12
Ambient air temperature: 30°C.Conductor operating temperature: 60°C.
The above current ratings are based on only two cores loaded simultaneously.
Where more than two cores are loaded simultaneously and known to carry appreciable current* the following factors apply:
*The normal rating may be taken in cases where the number of cores carrying appreciable current does not exceed the squareroot of the total number of cores.
For ambient air temperatures other than 30°C the following factors should be applied:
Ambient air temp °C 10 15 20 25 30 35 40 45 50 Rating factor 1.29 1.22 1.15 1.08 1.0 0.91 0.82 0.71 0.58
No. of cores loaded 3 4 5 6 7 10 Rating factor 0.87 0.78 0.72 0.67 0.63 0.56
08•26Products. Technology. Services. Delivered Globally.
anixter.com
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Screening Conductor
PADS Number Anixter Cat.Number
Nominal Area
mm2
Stranding
#/mm
Sheath Nominal OuterDiametermm
Nominal Weight
Kg/km
091/010267 HORNET 150 19/3.25 Bare 16.25 443
091/010318 HORNET-PVC 150 19/3.25 PVC Black 19.45 630
091/030336 HORNET-PVC-03 150 19/3.25 PVC Red 19.45 630
091/030337 HORNET-PVC-05 150 19/3.25 PVC Yellow 19.45 630
091/012189 HORNET-ZHLS 150 19/3.25 ZHLS Black 19.45 630
091/010268 COCKROACH 250 19/4.22 Bare 21.10 754
091/010319 COCKROACH-PVC 250 19/4.22 PVC Black 24.30 995
- CENTIPEDE 400 37/3.78 Bare 26.50 1150
Specification
• NR/PS/TEL/31102
Application
An Aluminium conductor used to screen Telecommunication Cables from electrical interference within the Network Railinfrastructure.
Construction
• Conductors: Stranded Aluminium to BS215 Part 1.
• Sheath Options:
Bare. Greased or Un-greased options available.PVCZHLS
Rail Cables
08•27
08•28Products. Technology. Services. Delivered Globally.
anixter.com
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Rail Cables • Rolling Stock Cables
Single-Core Cross-Linked PolyolefinInsulated Cable
Construction
All cables employ flexible conductors with flame retardant cross-linked polyolefin insulation, which combines outstandingoil-resistance with superior thermal, electrical and physical properties.
Specification
• In accordance with rail specification TDE/76/P/16
• Conductor: Class 5 tinned copper conductorsto BS EN 60228
• Insulation: Grey cross-linked polyolefin insulation*
• Flame Retardant to BS EN 60332-3-22 (NMV 7)(IEC 60332-3-22 Category A)
• Meets MIL-W-22759 cold bend test (-65°C, 2" mandrel)
• Voltage Rating: 1900/3300 V
• Temperature Rating: 90°C maximum conductoroperating temperature (per TDE/76/P/16)May also be used at conductor temperatures up to andincluding 125°C
*The insulation material is cross-linked by an irradiation process and displays the following characteristics:Minimum oxygen index: 29%.Maximum HCL emission @ 800°C: 5%.
When using these cables at or near 125°C conductor operating temperature care should be exercised to ensure that anymaterials that come into contact with the cables are not adversely affected.
Application
Designed for traction and rolling stock these single-core cables are suitable for fixed installations within vehicles, jumperconnections between vehicles and between motor and underframe. These cables are also designed for use in connections tocoil windings, wiring of motor vehicles, control panels and switchgear and may also be used in high temperature zones.
08•29Products. Technology. Services. Delivered Globally.
anixter.com
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Rail Cables • Rolling Stock Cables
Single-Core Cross-Linked PolyolefinInsulated Cable
PADS CatalogueNumber
Anixter Number Conductor NominalOuterDiameter
mm
NominalWeightDiameter
kg/km
MinimumBendingRadiusFixed Bend
mm
Number andNominalDiameterof Strands#/mm
NominalConductorArea
mm2
ThicknessofInsulation
mm
- RAD-0005 16/0.2 0.50 0.80 2.59 14 16
- RAD-0007 24/0.2 0.75 0.80 2.82 17 17
- RAD-0010 32/0.2 1.0 0.80 2.92 19 18
6/110950 RAD-00116 37/0.2 1.16 0.80 3.00 20 18
- RAD-0015 30/0.25 1.5 0.80 3.32 24 20
6/110960 RAD-0018 37/0.25 1.8 0.80 3.5 28 30
- RAD-0025 50/0.25 2.5 0.80 3.76 35 30
6/110970 RAD-0026 37/0.3 2.6 0.80 3.90 37 30
- RAD-0040 56/0.3 4.0 0.80 4.29 50 30
6/110980 RAD-0047 37/0.4 4.7 1.00 4.80 63 30
- RAD-0060 84/0.3 6.0 1.20 5.67 80 40
6/110990 RAD-0077 61/0.4 7.7 1.20 6.00 99 40
6/111000 RAD-0100 80/0.4 10 1.20 7.00 124 50
6/111010 RAD-0160 126/0.4 16 1.20 8.10 184 50
6/111020 RAD-0250 196/0.4 25 1.60 10.30 287 70
6/111030 RAD-0350 276/0.4 35 1.60 11.70 398 80
6/111040 RAD-0500 396/0.4 50 1.70 13.70 566 90
6/111050 RAD-0700 360/0.5 70 1.80 16.00 777 100
6/111060 RAD-0950 475/0.5 95 2.00 18.50 1014 120
6/111070 RAD-1200 608/0.5 120 2.20 20.40 1289 130
6/111080 RAD-1500 756/0.5 150 2.30 22.60 1586 140
6/111090 RAD-1850 925/0.5 185 2.40 24.80 1921 150
6/111100 RAD-2400 1221/0.5 240 2.40 27.80 2502 170
6/111110 RAD-3000 1525/0.5 300 3.00 32.00 3186 200
6/111120 RAD-4000 2013/0.6 400 3.00 36.00 4267 220
PADS numbers referenced were originally known as BR (British Rail) catalogue numbers.
08•30Products. Technology. Services. Delivered Globally.
anixter.com
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Rail Cables • Rolling Stock Cables
Single-Core Cross-Linked PolyolefinInsulated Cable - Technical Information
Derating factors for ambient temperatures other than 40°C:
Ambient air temp °C 20 25 30 35 40 45 50 55 60 70 80Rating factor 1.11 1.08 1.06 1.03 1.0 0.97 0.94 0.91 0.87 0.80 0.73
Ambient air temp °C 25 30 35 40 50 55Derating factor 1.03 1.00 0.97 0.95 0.89 0.86
Derating factor for maximum conductor temperature other than 125°C ambient 40°C:
Max conductor temp °C 125 100 90 70 Derating factor 1.0 0.84 0.77 0.59
Reference should also be made to the IEE Wiring Regulations 17th Edition to ensure compliance.
Derating factors for variation in ambient temperatures:
Ambient air temp °C 85 90 95 100Rating factor 0.69 0.64 0.59 0.54
1. Current ratings are based upon one isolated cable in free air.2. Ambient air temperature 40°C. Conductor temperature 125°C.
Nominal conductor area mm2 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95Continuous current ratings A 35 47 63 81 112 150 199 246 306 379 458
Nominal conductor area mm2 120 150 185 240 300 400Continuous current ratings A 530 610 695 819 941 1127
08•31Products. Technology. Services. Delivered Globally.
anixter.com
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Current ratings for 125°C rated wire based on IEE Wiring Regulations installation methods:
Rail Cables • Rolling Stock Cables
Nominal ConductorArea
mm2
Installation Method 3 (‘Enclosed’) Installation Method 1 (‘Clipped Direct’)2 Cables, SinglePhase a.c. or d.c.
3 or 4 Cables,Three Phase a.c.
2 Cables, SinglePhase a.c. or d.c.
3 or 4 Cables,Three Phase a.c.
1.0 19 17 21 191.5 24 21 28 252.5 33 29 37 354.0 44 39 51 466.0 57 50 65 5910 79 69 90 8116 105 94 120 10925 139 123 157 14435 172 151 195 17850 208 185 251 23070 265 236 323 29595 320 286 392 360120 371 330 455 418150 414 362 526 482185 473 413 602 552240 559 488 711 651300 645 563 820 752400 754 659 958 875
Single-Core Cross-Linked PolyolefinInsulated Cable - Technical Information
Nominal ConductorAreamm2
Voltage Drop Per Ampere Per Metre
d.c.mV
Single Phase a.c.mV
3 Phase a.c.mV
1.0 51.0 51.0 44.01.5 35.0 35.0 31.02.5 21.0 21.0 18.04.0 13.0 13.0 12.06.0 8.7 8.7 7.510 5.0 5.0 4.316 3.2 3.2 2.725 2.0 2.03 1.835 1.4 1.45 1.350 1.0 1.01 0.8870 0.71 0.73 0.6395 0.54 0.56 0.49120 0.42 0.45 0.39150 0.34 0.38 0.33185 0.28 0.32 0.28240 0.21 0.26 0.23300 0.17 0.23 0.20
VOLTAGE DROP
30°C ambient air temperature. 125°C conductor operating temperature.
08•32Products. Technology. Services. Delivered Globally.
anixter.com
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Rail Cables • Rolling Stock Cable
Construction
• Conductors: Flexible stranded tinned copper Class 5according to IEC 60228 with optional separator tape
• Insulation: Type E1 104 cross-linked halogen free rubber,black FLAMEX Z
• Sheath: Type EM 104 according to EN 50264-2. Specialcross-linked halogen free rubber, FLAMEX Z, black orgreen/yellow
EN 50264-2-1 Flexible Single-Core Cables Standard Wall Insulation FLAMEX Z Types
Specifications
• Marking: FLAMEX Z, EN 50264-2-1, voltage rating,conductor size, hazard level (ex MM), Nexans, factorycode, batch number/year
• Standards: According to: EN 50264-2-1, EN 45555, NF F 16-101, BS 6853, DN 5510
• Minimum Bending Radius: Dynamic use: 5 to 8 x outerdiameter. Static use: 4 x outer diameter
• Voltage: 600/1000 V
• Temperature Rating: +90°C/120°C
Application
Strictly halogen free, these wires present high chemical resistance and high mechanical properties. They are recommended forinstallation in railway vehicles (locomotives, trains, trolley-busses...).
A 120°C conductor temperature is allowed for a 20000 hours cumulative working time. The external sheath is oil and diesel oilresistant, ozone and UV resistant.
08•33Products. Technology. Services. Delivered Globally.
anixter.com
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Rail Cables • Rolling Stock Cable
EN 50264-2-1 Flexible Single-Core Cables Standard Wall Insulation FLAMEX Z Types
Anixter Number Nexans ThicknessofInsulationmm
mini
mm
maxi
mm
Theoretical
mm
Average Weight
Kg/km
Number Cross Section
mm2
Diameter
mm
Black Sheath
EN50264-1C-0015-02 2601010015 1.5 1.5 0.8 3 3.5 3.3 24
EN50264-1C-0025-02 2601010025 2.5 1.95 0.8 3.4 3.9 3.7 33
EN50264-1C-0040-02 2601010040 4 2.5 0.8 3.9 4.6 4.3 48
EN50264-1C-0060-02 2601010060 6 3 0.9 4.6 5.4 5 68
EN50264-1C-0100-02 2601010100 10 3.9 1.1 5.8 6.8 6.2 114
EN50264-1C-0160-02 2601010160 16 5 1.1 7.2 8.5 7.4 170
EN50264-1C-0250-02 2601010250 25 6.4 1.3 8.6 10 9.1 257
EN50264-1C-0350-02 2601010350 35 7.7 1.3 10.2 11.5 10.4 351
EN50264-1C-0500-02 2601010500 50 9.2 1.5 11.6 13.5 12.2 490
EN50264-1C-0700-02 2601010700 70 11 1.5 13.3 15.5 14.05 686
EN50264-1C-0950-02 2601010950 95 12.6 1.6 14.9 17.4 16.15 896
EN50264-1C-1200-02 2601011200 120 14.2 1.6 16.5 19.3 17.4 1130
Green/Yellow Sheath
EN50264-1C-0015-60 2601110015 1.5 1.5 0.8 3 3.5 3.3 24
EN50264-1C-0025-60 2601110025 2.5 1.95 0.8 3.4 3.9 3.7 33
EN50264-1C-0040-60 2601110040 4 2.5 0.8 3.9 4.6 4.3 48
EN50264-1C-0060-60 2601110060 6 3 0.9 4.6 5.4 5 68
Overall Diameter mmConductor
08•34Products. Technology. Services. Delivered Globally.
anixter.com
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Rail Cables • HUBER+SUHNER
RADOX® 4 GKW-AX
Composition of Cable
1. Conductor - stranded tin plated copper, acc. to IEC60228 cl.5.2. Insulation - RADOX® GKW K.3. Sheath - RADOX® GKW S, colour: black.
Specifications
• Conductor Class: IEC 60228 Class 5
• Number of Conductors: 1
• Cross Section: 1 - 400mm2
• Voltage Rating: 1800/3000 V a.c., 2700/4500 V d.c.
• Temperature Range: -40°C to +120°C
Single-Core
Characteristics and Specialities
• Resistance to oil, diesel oil, abrasion, ozone and weathering
• Improved fire performance
• Halogen free
• Low smoke
• Low toxicity
• Flame retardant
• Soldering resistant
• Easy to strip
• Flexible
• Weight optimised
Standard Fire Protection on Railway Vehicles
BS 6853 Category int. Ia, Ib, II/ext. Ia, Ib, II
DIN 5510--2 Protection level 1, 2, 3, 4
NF F16--101 Class C/F0
NF F16-101 Category int. A1, A2, B/ext. A1, A2, B
Standards
Application
For protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts, especially suitablefor applications in diesel, for direct and alternating voltage operations.
08•35Products. Technology. Services. Delivered Globally.
anixter.com
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Single-Core
Rail Cables • HUBER+SUHNER
RADOX® 4 GKW-AX
Anixter HUBER +Part Number SUHNER
Cable InsulationThicknessminimum mm
CableDiameternom mm
ConductorResistance @ 20ºCR20 Ω/km
Capacitance**C nompF/m
Fire WeightTypemm2
Load
kJ/
Copperkg/100m
Cablekg/100m
4GKW-AX-0010 12555986 1 32 x 0.20 1.30±0.05 0.775 2.85±0.10 20.00 208 112 0.9 1.7
4GKW-AX-0015 12536686 1.5 30 x 0.26 1.52±0.05 0.70 3.20±0.10 13.70 254 154 1.3 2.2
4GKW-AX-0025 12536692 2.5 50 x 0.26 1.95±0.05 0.80 3.75±0.10 8.21 292 200 2.2 3.4
4GKW-AX-0040 12536694 4 56 x 0.31 2.46±0.10 0.85 4.50±0.10 5.09 322 275 3.4 5.2
4GKW-AX-0060 12536696 6 84 x 0.31 2.93±0.10 0.90 5.10±0.15 3.39 350 340 5.2 7.4
4GKW-AX-0100 12545527 10 80 x 0.41 3.89±0.20 1.00 6.35±0.15 1.95 392 489 9.1 12
4GKW-AX-0160 12545528 16 119 x 0.41 5.30±0.20 1.20 8.30±0.20 1.24 447 834 13 18
4GKW-AX-0250 12545529 25 182 x 0.41 6.60±0.20 1.35 10.2±0.30 0.795 451 1260 21 28
4GKW-AX-0350 12545530 35 266 x 0.41 7.80±0.20 1.55 11.7±0.30 0.565 489 1568 30 39
4GKW-AX-0050 12545531 50 378 x 0.41 9.30±0.20 1.85 13.6±0.30 0.393 512 1960 43 55
4GKW-AX-0700 12545532 70 348 x 0.51 11.4±0.30 1.75 15.6±0.30 0.277 619 2514 61 73
4GKW-AX-0950 12545533 95 444 x 0.51 12.8±0.30 1.90 17.3±0.30 0.210 640 2743 78 94
4GKW-AX-1200 12544522 120 551 x 0.51 14.6±0.40 2.10 19.6±0.30 0.164 650 3485 94 118
4GKW-AX-1500 12545534 150 722 x 0.51 16.8±0.40 2.15 21.9±0.30 0.132 719 3998 127 151
4GKW-AX-1850 12544523 185 874 x 0.51 18.3±0.40 2.35 23.8±0.30 0.108 725 4751 153 180
4GKW-AX-2400 12547684 240 1147 x 0.51 21.1±0.60 2.50 26.9±0.30 0.0817 791 5958 201 229
4GKW-AX-3000 12552906 300 1443 x 0.51 23.7±0.60 2.50 29.7±0.30 0.0654 918 6510 253 291
4GKW-AX-4000 12555997 400 2016 x 0.51 29.1±0.70 2.60 35.8±0.50 0.0495 955 8741 353 404
* typical value x single wire diameter, conductor resistance at 20°C according to IEC 60228.** capacity in water, typical value.
Other colours on request.
ConductorDiameternom mm
ConductorConstruction*no x mm
08•36Products. Technology. Services. Delivered Globally.
anixter.com
Rail Cables • Rolling Stock Cables1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Single-Core Equipment Wire
Construction
The wires feature flame retardant zero halogen insulation which combines outstanding oil-resistance with superior thermal,electrical and physical properties.
Specifications
• In accordance with BS6853 Category 1A
• Conductors: Stranded tinned annealed copperconductors to BS EN 60228
• Insulation: Inner modified zero halogen insulation andouter polyaromatic zero halogen thermoplastic
• Voltage Rating (Uo/U): 600/1000 V
• Temperature Rating: 120°C maximum conductoroperating temperature
Application
Anixter rolling stock wire is designed to interconnect between modules, PCBs, plugs and sockets and internal terminalblocks/boards on or within electronic equipment.
08•37Products. Technology. Services. Delivered Globally.
anixter.com
Rail Cables • Rolling Stock Cables1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Single-Core Equipment Wire
• The current ratings quoted are based on single cable isolated in air at an ambient air temperature of 90°C
• Cables are also available in 22 AWG (19/0.15mm) and 10 AWG (37/0.4mm) conductor sizes
Anixter Number
Size (AWG)
Number and NominalDiameterof Strands#/mm
Nominal ConductorArea
mm2
Maximum OuterDiameter
mm
NominalWeight
kg/km
Insulation Colour
CurrentRating
A
A4BH-1060-01 20 19/0.2 0.60 1.45 6.5 White 5
A4BH-1060-02 20 19/0.2 0.60 1.45 6.5 Black 5
A4BH-1060-03 20 19/0.2 0.60 1.45 6.5 Red 5
A4BH-1060-04 20 19/0.2 0.60 1.45 6.5 Green 5
A4BH-1060-05 20 19/0.2 0.60 1.45 6.5 Yellow 5
A4BH-1060-06 20 19/0.2 0.60 1.45 6.5 Blue 5
A4BH-1060-06L 20 19/0.2 0.60 1.45 6.5 Light Blue 5
A4BH-1060-07 20 19/0.2 0.60 1.45 6.5 Brown 5
A4BH-1060-08 20 19/0.2 0.60 1.45 6.5 Orange 5
A4BH-1060-09 20 19/0.2 0.60 1.45 6.5 Grey 5
A4BH-1060-10 20 19/0.2 0.60 1.45 6.5 Violet 5
A4BH-1060-12 20 19/0.2 0.60 1.45 6.5 Pink 5
A4BH-1060-60 20 19/0.2 0.60 1.45 6.5 Green/Yellow 5
A4BH-1135-01 16 19/0.3 1.35 1.95 14.0 White 8
A4BH-1135-02 16 19/0.3 1.35 1.95 14.0 Black 8
A4BH-1135-03 16 19/0.3 1.35 1.95 14.0 Red 8
A4BH-1135-04 16 19/0.3 1.35 1.95 14.0 Green 8
A4BH-1135-05 16 19/0.3 1.35 1.95 14.0 Yellow 8
A4BH-1135-06 16 19/0.3 1.35 1.95 14.0 Blue 8
A4BH-1135-07 16 19/0.3 1.35 1.95 14.0 Brown 8
A4BH-1135-08 16 19/0.3 1.35 1.95 14.0 Orange 8
A4BH-1135-09 16 19/0.3 1.35 1.95 14.0 Grey 8
A4BH-1135-10 16 19/0.3 1.35 1.95 14.0 Violet 8
08•38Products. Technology. Services. Delivered Globally.
anixter.com
Rail Cables • Rolling Stock Cables1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Single and Multicore Screened Equipment Cable
Construction
This range of cables feature flame retardant zero halogen insulation which combines outstanding oil-resistance with superiorthermal, electrical and physical properties. These cables also incorporate a tinned copper wire braid screen.
Specifications
• In accordance with BS6853 Category 1A
• Conductors: Stranded tinned annealed copperconductors to BS EN 60228
• Insulation: Inner modified zero halogen insulation andouter polyaromatic zero halogen thermoplastic
• Core Identification:Single-core - redTwo core - red, blueThree core - red, blue, greenFour core - red, blue, green, yellowFive core - red, blue, green, yellow, whiteSix core - red, blue, green, yellow, white, black
• Screen: Tinned copper wire braid screen, 85% coverage
• Outer Sheath: Black outer sheath irradiation cross-linkedzero halogen
• Voltage Rating (Uo/U): 600/1000 V
• Temperature Rating: 105°C maximum conductoroperating temperature
Application
Anixter’s screened equipment cables are designed for wiring and connection on and within electronic equipment and may alsobe used for complete vehicle installation.
08•39Products. Technology. Services. Delivered Globally.
anixter.com
Rail Cables • Rolling Stock Cables1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Single and Multicore Screened Equipment Cable
Also available in 22 AWG (19/0.15mm) and 16 AWG (19/0.3mm) conductor sizes.
Anixter NumberConductor Maximum
OuterDiameter
mm
NominalWeight
kg/km
BraidWireSize
mm
Number ofCores
Size(AWG)
Number andNominalDiameterof Strands#/mm
NominalConductorArea
mm2
A4BH-1060-A-02 1 20 19/0.2 0.60 3.20 22 0.102
A4BH-2060-B-02 2 20 19/0.2 0.60 4.70 50 0.102
A4BH-3060-B-02 3 20 19/0.2 0.60 5.00 60 0.102
A4BH-4060-B-02 4 20 19/0.2 0.60 5.15 75 0.102
A4BH-5060-B-02 5 20 19/0.2 0.60 6.00 86 0.102
A4BH-6060-B-02 6 20 19/0.2 0.60 6.50 96 0.102
08•40Products. Technology. Services. Delivered Globally.
anixter.com
Rail Cables • Rolling Stock Cables1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
This section covers LFH cables for power, control, instrumentation and communication use on LUL rolling stock.
RSE/STD/024 supersedes LUL specifications RME516 and RME704.
Benefits of RSE/STD/024 Cables
• High performance LFH insulation meeting specificelectrical, mechanical and fire performance properties
• Service life in excess of 100,000 hours at 85°C
• Easily stripped using conventional tooling
• Resistance over a wide range of temperatures to:
- abrasion
- cut-through
- impact
- notch propagation
• Excellent resistance to:
- fluids
- ozone
- weathering
• Non-halogenated
• Flame retardant
• Very low smoke emission
• Negligible corrosive fume emission
• Stable electrical properties
• High level of voltage withstand
• High insulation resistance
• Excellent resistance to surface and arc tracking
LFH Cables to RSE/STD/024 for LUL
08•41Products. Technology. Services. Delivered Globally.
anixter.com
Rail Cables • Rolling Stock Cables1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Single-core, tinned copper concentric conductor, reducedwall LFH insulation (red).Nominal voltage to earth 600 V a.c./1000 d.c.
Type 1
Single-core, tinned non-concentric conductor, standard wallLFH insulation (red).Nominal voltage to earth 600 V a.c./1000 d.c.
Type 2
Cables to RSE/STD/024 Issue 6
Single-core, tinned copper non-concentric conductor,enhanced wall LFH insulation (red).Nominal voltage to earth 600 V a.c./1000 d.c.
Type 3
Single-core, tinned copper concentric conductor, reducedwall LFH insulation (violet)*.Nominal voltage to earth 30 V a.c./50 V d.c.
Type 4
Single-core, tinned copper non-concentric conductor,standard wall LFH insulation (violet)*.Nominal voltage to earth 30 V a.c./50 V d.c.
Type 5
Multicore, tinned copper non-concentric conductor,standard wall LFH insulation, enhanced wall LFH outer sheath (black).Nominal voltage to earth 600 V a.c./1000 V d.c.Core identification: cores will be number printed, in acontrasting colour, on red LFH insulation.N.B. Cores are Type 2 cables.
Type 6
Type 7
Single and multipair, tinned copper non-concentricconductor, standard wall LFH insulation, individuallyscreened with drain wire in contact with tinned copper wirebraid, standard or enhanced wall LFH outer sheath (black).Nominal voltage to earth 30 V a.c./50 V d.c.Pair identification: pairs shall contain one blue and onebrown core.N.B. Cores are Type 5 cables.
Type 8
Single and multipair, tinned copper concentric conductor,reduced wall LFH insulation, individually screened with drainwire in contact with tinned copper wire braid, standard wallLFH outer sheath.Nominal voltage to earth 30 V a.c./50 V d.c.Pair identification: pairs shall contain one blue and onebrown core.N.B. Cores are Type 4 cables.
*Where specified for a safety circuit, insulation shall be yellow.
Type 9
Anixter also stock a complete range of accessories for the cables featured in this section. More details are available on request.
Multicore, tinned copper non-concentric conductor,standard wall LFH insulation, enhanced wall LFH outer sheath (black).Nominal voltage to earth 30 V a.c./50 V d.c.Core identification: cores will be number printed, in acontrasting colour, on violet LFH insulation.N.B. Cores are Type 5 cables.
08•42Products. Technology. Services. Delivered Globally.
anixter.com
Rail Cables • Rolling Stock Cables1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
RIA 10 Flexible Multicore Rubber Insulated andSheathed Cables for Diesel and Electric Vehicles
Specifications
• In accordance with BRB/RIA specification No.10
• Conductors: Flexible Class 5 tinned copper conductorsto BS EN 60228
• Insulation: EPR insulation Type GP1 to BS7655
• Core Identification: Cores will be number printed, ina contrasting colour, on blue insulation (conductors upto 2.5mm2) and red insulation for cables having4.0mm2 conductors.Alternatively, the manufacturer may employ numberproofed tape on each core, the insulation colours beingas above
• Sheath: Black heavy duty PCP sheath Type RS2 to BS7655
• Flame Retardant to BS EN 60332-1-2
• Voltage Rating: 300/500 V, 600/1000 V
• Temperature Rating: 60°C maximum conductoroperating temperature
Construction
These cables feature flexible conductors with EPR insulation and HOFR PCP outer sheath.
Application
Anixter’s flexible multicore control cable is designed for use within railway vehicles or as jumper cable between railwayvehicles and may also be used in other applications where flexible control cable is required.
08•43Products. Technology. Services. Delivered Globally.
anixter.com
Rail Cables • Rolling Stock Cables1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Flexible Multicore Rubber Insulated and SheathedCables for Diesel and Electric Vehicles
PADS CatalogueNumber
AnixterNumber
Number of Cores
Number and NominalDiameterof Strands
#/mm
NominalConductorArea
mm2
Thickness ofInsulation
mm
ThicknessofSheath
mm
Maximum OuterDiameter
mm
Nominal Weight
kg/km
MinimumBendingRadiusFixed/Flexingmm
300/500 V Rated Cables
6/153501 A4BT2-C012-02 12 32/0.2 1.0 0.80 1.60 20.90 450 90/150
6/154220 A4BT-C019-02 19 50/0.25 2.5 0.90 3.30 29.40 1200 120/180
6/155020 A4BT-C027-02 27 50/0.25 2.5 0.90 3.40 33.20 1500 150/230
6/155925 A4BT1-C036-02 36 30/0.25 1.5 0.80 4.30 35.80 1600 170/250
6/156250 A4BT1-C042-02 42 30/0.25 1.5 0.80 4.40 39.30 1900 190/280
600/1000 V Rated Cables
6/153300 A4BT3-C010-02 10 50/0.25 2.5 1.40 3.30 28.90 910 120/180
6/154300 A4BT3-C020-02 20 56/0.3 4.0 1.40 5.20 43.80 2400 210/310
Multipair cables are also available with or without copper wire braid screens.
08•44Products. Technology. Services. Delivered Globally.
anixter.com
Rail Cables • Rolling Stock Cables1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
RIA 21 Single-Core Rubber Insulated Cablesfor Traction and Rolling Stock
Construction
All cables incorporate a flexible conductor with dual layer insulation comprising of an EPR inner layer and HOFR outer layer.
Specifications
• In accordance with BRB/LUL/RIA specification No. 21(these cables were formerly covered in BRB/RIA 7and BRB/RIA 11)
• Conductors: Flexible Class 5 tinned copper conductorsto BS EN 60228
• Insulation: Composite rubber insulation Type FR1 or FR2(1900/3300 V grade only) to BS7655. The compositerubber insulation employs an EPR inner layer and a CSPouter layer, the two layers being applied simultaneously ina dual extrusion process
• Flame Retardant to BS EN 60332-1-2
• Voltage Rating: 300/500 V, 600/1000 V and 1900/3300 V
• Temperature Rating: 85°C maximum conductoroperating temperature
Application
This Anixter range of cables is designed for use in protected or exposed installation on traction and rolling stock withinvehicles, or jumper connections between vehicles and may also find applications in the connection of coil windings and flexiblepower leads.
08•45Products. Technology. Services. Delivered Globally.
anixter.com
Rail Cables • Rolling Stock Cables1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Single-Core Rubber Insulated Cablesfor Traction and Rolling Stock
PADS CatalogueNumber
Anixter Number Conductor MaximumOuterDiameter
mm
NominalWeight
kg/km
MinimumBendingRadiusFixed Bend
mm
*RIA ItemNumberNumber and
NominalDiameterof Strands#/mm
NominalConductorArea
mm2
Thicknessofcovering
mm300/500 V Cables for Protected Installations6/101365 A4CY1-0010-02 32/0.2 1.0 0.80 3.70 23 8 16/101600 A4CY1-0015-02 30/0.25 1.5 0.80 4.00 29 8 26/101900 A4CY1-0025-02 50/0.25 2.5 0.90 4.60 42 10 36/102200 A4CY1-0040-02 56/0.3 4.0 1.00 5.40 61 11 46/102400 A4CY1-0060-02 84/0.3 6.0 1.00 6.50 89 13 56/102800 A4CY1-0100-02 80/0.4 10 1.20 7.90 141 16 66/103030 A4CY1-0160-02 126/0.4 16 1.20 9.00 204 18 7600/1000 V Cables for Protected Installations6/104800 A4CY2-0015-02 30/0.25 1.5 1.40 5.20 41 11 86/105192 A4CY2-0025-02 50/0.25 2.5 1.40 5.60 53 12 96/105600 A4CY2-0040-02 56/0.3 4.0 1.40 6.30 73 13 106/105950 A4CY2-0060-02 84/0.3 6.0 1.50 7.50 104 15 116/106870 A4CY2-0100-02 80/0.4 10 1.50 8.50 152 17 126/108155 A4CY2-0160-02 126/0.4 16 1.50 9.60 217 20 136/108500 A4CY2-0250-02 196/0.4 25 1.60 11.40 322 40 146/108790 A4CY2-0350-02 276/0.4 35 1.60 12.80 430 40 156/109028 A4CY2-0500-02 396/0.4 50 1.70 14.80 596 50 166/109330 A4CY2-0700-02 360/0.5 70 1.80 17.20 807 60 176/109580 A4CY2-0950-02 475/0.5 95 2.00 19.70 1054 60 186/109680 A4CY2-1200-02 608/0.5 120 2.20 21.90 1345 70 196/109900 A4CY2-1500-02 756/0.5 150 2.30 24.10 1648 80 206/110200 A4CY2-1850-02 925/0.5 185 2.40 26.30 1992 80 211900/3300 V Cables for Protected Installations6/121350 A4CY3-0025-02 50/0.25 2.5 2.80 8.50 100 17 236/121400 A4CY3-0100-02 80/0.4 10 2.80 11.30 216 40 246/121680 A4CY3-0160-02 126/0.4 16 2.80 12.40 288 40 256/108504 A4CY3-0250-02 196/0.4 25 2.80 13.80 392 50 266/108790 A4CY3-0350-02 276/0.4 35 2.80 15.20 509 50 276/109040 A4CY3-0500-02 396/0.4 50 2.80 17.10 682 60 286/109346 A4CY3-0700-02 360/0.5 70 2.80 19.20 894 60 296/109585 A4CY3-0950-02 475/0.5 95 3.00 22.00 1168 70 306/109685 A4CY3-1200-02 608/0.5 120 3.00 23.50 1433 80 316/109990 A4CY3-1500-02 756/0.5 150 3.00 25.50 1734 110 326/110205 A4CY3-1850-02 925/0.5 185 3.00 27.50 2073 110 336/110385 A4CY3-2400-02 1221/0.5 240 3.00 30.50 2657 130 346/110450 A4CY3-3000-02 1525/0.5 300 3.00 33.80 3279 140 356/110510 A4CY3-4000-02 2013/0.5 400 3.00 37.80 4229 150 361900/3300 V Cables for Exposed Installations6/122505 A4CY4-0700-02 360/0.5 70 5.0 24.20 1141 80 376/122810 A4CY4-0950-02 475/0.5 95 5.0 26.30 1404 110 386/123105 A4CY4-1200-02 608/0.5 120 5.0 27.80 1685 120 396/123295 A4CY4-1500-02 756/0.5 150 5.0 29.80 2011 120 406/123455 A4CY4-1850-02 925/0.5 185 5.0 32.10 2385 130 416/123805 A4CY4-2400-02 1221/0.5 240 5.0 35.10 3001 150 426/123965 A4CY4-3000-02 1525/0.5 300 5.0 38.10 3631 160 436/124155 A4CY4-4000-02 2013/0.5 400 5.0 42.10 4621 170 44
*RIA = Railway Industry Association.
08•46Products. Technology. Services. Delivered Globally.
anixter.com
Rail Cables • Rolling Stock Cables1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Technical Information
The above ratings are based on a single cable isolated in free air and assumes ambient air temperature of 30°C and conductoroperating temperature of 85°C.
Where cables are to be used in ambient temperatures other than 30°C the following rating factors should be applied:
Where cables are to be grouped, the following factors should be applied:
• Item numbers 26-36 inclusive may also be used in exposed installations but only when rated at 600/1000 V
• Cables below 25mm2 shall not be used in exposed installations and will normally be installed in ducts, conduit, cabinets, etc.
Ambient air temp °C 25 30 35 40 45 50 55 60 65 70 75 80Rating factor 1.02 1.0 0.95 0.90 0.85 0.80 0.74 0.67 0.60 0.52 0.43 0.30
Nominal conductor area mm2 1.0 1.5 2.5 4.0 6.0 10 16 25 35 50 70 Continuous current ratings A 23 28 38 52 68 96 128 171 215 270 337
Nominal conductor area mm2 404 478 549 627 756 883 1070Continuous current ratings A 95 120 150 185 240 300 400
No. of cable grouped and touching 2 3 4 5 6 7 8Rating factor 0.8 0.7 0.65 0.6 0.56 0.53 0.5