33
Test report No. : 12725753M Page : 1 of 33 Issued date : April 15, 2019 UL Japan, Inc. Kashima EMC Lab. 1614, Mushihata, Katori-shi, Chiba-ken, 289-0341 Japan Telephone : +81 478 88 6500 Facsimile : +81 478 82 3373 Report Cover Page - 13-EM-F0429 Issue # 14.0 RADIO TEST REPORT Test Report No. : 12725753M Applicant : TAIYO YUDEN CO., LTD. Type of Equipment : Bluetooth low energy / ANT / 802.15.4 Module Model No. : EYSKJN Test standard : EN 300 328 V2.1.1 (Except Radiated emission tests) Test Result : Complied (Refer to Section 3.2) 1. This test report shall not be reproduced in full or partial, without the written approval of UL Japan, Inc. 2. The results in this report apply only to the sample tested. 3. This sample tested is in compliance with the above standard(s). 4. The test results in this report are traceable to the national or international standards. 5. This test report covers Radio technical requirements. It does not cover administrative issues such as Manual or non-Radio test related Requirements. (if applicable) 6. The all test items in this test report are conducted by UL Japan, Inc. Kashima EMC Lab. 7. The opinions and the interpretations to the result of the description in this report are outside scopes where UL Japan has been accredited. 8. The information provided from the customer for this report is identified in SECTION 1 Date of test: February 21 - 25, 2019 RTL02610 Representative test operator: Kazuhiro Ando Engineer Consumer Technology Division Approved by : Tomoyuki Yamashita Leader Consumer Technology Division The testing in which "Non-accreditation" is displayed is outside the accreditation scopes in UL Japan. There is no testing item of "Non-accreditation"

RADIO TEST REPORT - YUDEN

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Test report No. : 12725753M Page : 1 of 33 Issued date : April 15, 2019

UL Japan, Inc. Kashima EMC Lab. 1614, Mushihata, Katori-shi, Chiba-ken, 289-0341 Japan Telephone : +81 478 88 6500 Facsimile : +81 478 82 3373 Report Cover Page - 13-EM-F0429 Issue # 14.0

RADIO TEST REPORT

Test Report No. : 12725753M

Applicant : TAIYO YUDEN CO., LTD. Type of Equipment : Bluetooth low energy / ANT / 802.15.4 Module Model No. : EYSKJN Test standard : EN 300 328 V2.1.1

(Except Radiated emission tests) Test Result : Complied (Refer to Section 3.2)

1. This test report shall not be reproduced in full or partial, without the written approval of

UL Japan, Inc. 2. The results in this report apply only to the sample tested. 3. This sample tested is in compliance with the above standard(s). 4. The test results in this report are traceable to the national or international standards. 5. This test report covers Radio technical requirements. It does not cover administrative issues such as

Manual or non-Radio test related Requirements. (if applicable) 6. The all test items in this test report are conducted by UL Japan, Inc. Kashima EMC Lab. 7. The opinions and the interpretations to the result of the description in this report are outside scopes

where UL Japan has been accredited. 8. The information provided from the customer for this report is identified in SECTION 1

Date of test: February 21 - 25, 2019

RTL02610

Representative test operator:

Kazuhiro Ando

Engineer Consumer Technology Division

Approved by :

Tomoyuki Yamashita Leader

Consumer Technology Division

The testing in which "Non-accreditation" is displayed is outside the accreditation scopes in UL Japan.

There is no testing item of "Non-accreditation"

40747
Pencil

Test report No. : 12725753M Page : 2 of 33 Issued date : April 15, 2019

UL Japan, Inc. Kashima EMC Lab. 1614, Mushihata, Katori-shi, Chiba-ken, 289-0341 Japan Telephone : +81 478 88 6500 Facsimile : +81 478 82 3373

REVISION HISTORY

Original Test Report No.: 12725753M

Revision Test report No. Date Page

revised Contents

- (Original)

12725753M April 15, 2019 - -

Test report No. : 12725753M Page : 3 of 33 Issued date : April 15, 2019

UL Japan, Inc. Kashima EMC Lab. 1614, Mushihata, Katori-shi, Chiba-ken, 289-0341 Japan Telephone : +81 478 88 6500 Facsimile : +81 478 82 3373

CONTENTS PAGE

SECTION 1: Customer information ................................................................................... 4

SECTION 2: Equipment under test (E.U.T.) ..................................................................... 4

SECTION 3: Test specification, procedures & results ...................................................... 6

SECTION 4: Operation of E.U.T. during testing ............................................................. 11

SECTION 5: Antenna Terminal Conducted Tests .......................................................... 14

APPENDIX 1: Test data ........................................................................................................ 15

RF Output Power ........................................................................................................................ 15 Power Spectral Density ............................................................................................................... 18 Occupied Channel Bandwidth .................................................................................................... 20 Transmitter unwanted emissions in the out-of-band domain ...................................................... 27 Receiver Blocking ....................................................................................................................... 29

APPENDIX 2: Test instruments ........................................................................................... 31

APPENDIX 3: Photographs of test setup ............................................................................. 32

Antenna terminal conducted tests other than Receiver Blocking ............................................... 32 Receiver Blocking ....................................................................................................................... 33

Test report No. : 12725753M Page : 4 of 33 Issued date : April 15, 2019

UL Japan, Inc. Kashima EMC Lab. 1614, Mushihata, Katori-shi, Chiba-ken, 289-0341 Japan Telephone : +81 478 88 6500 Facsimile : +81 478 82 3373

SECTION 1: Customer information

Company Name : TAIYO YUDEN CO., LTD. Address : 8-1,Sakae-cho, Takasaki-shi, Gunma 370-8522 ,Japan Telephone Number : +81-27-324-2313 Facsimile Number : +81-27-324-2314 Contact Person : Hideki Kato

The information provided from the customer is as follows; - Applicant, Type of Equipment, Model No. on the cover and other relevant pages - SECTION 1: Customer information - SECTION 2: Equipment under test (E.U.T.) - SECTION 4: Operation of E.U.T. during testing * The laboratory is exempted from liability of any test results affected from the information in SECTION 2 and 4.

SECTION 2: Equipment under test (E.U.T.) 2.1 Identification of E.U.T.

Type of Equipment : Bluetooth low energy / ANT / 802.15.4 Module Model No. : EYSKJN Serial No. : Refer to Clause 4.2 Rating : DC 3 V (DC 1.7 V - 3.6 V), 0.02 A Receipt Date of Sample (Information from test lab.)

: Feburary 14, 2019

Country of Mass-production : Japan Condition of EUT : Production prototype

(Not for Sale: This sample is equivalent to mass-produced items.) Modification of EUT : No Modification by the test lab

2.2 Product Description

Model: EYSKJN (referred to as the EUT in this report) is a Bluetooth low energy / ANT / 802.15.4 Module.

Test report No. : 12725753M Page : 5 of 33 Issued date : April 15, 2019

UL Japan, Inc. Kashima EMC Lab. 1614, Mushihata, Katori-shi, Chiba-ken, 289-0341 Japan Telephone : +81 478 88 6500 Facsimile : +81 478 82 3373

Radio Specification < Bluetooth (BT) Low Energy (LE) (1 Mbps, 2 Mbps) BLE Long range (500 kbps, 125 kbps)>

Radio Type : Transceiver Frequency of Operation : 2402 MHz - 2480 MHz Modulation : GFSK Power Supply (radio part input) : DC 1.7 V - 3.6 V Antenna type : Monopole Antenna Antenna Gain : -1.5 dBi Operation temperature range : -40 deg.C. to +105 deg.C.

< ANT (1 Mbps) >

Radio Type : Transceiver Frequency of Operation : 2402 MHz - 2480 MHz Modulation : GFSK Power Supply (radio part input) : DC 1.7 V - 3.6 V Antenna type : Monopole Antenna Antenna Gain : -1.5 dBi Operation temperature range : -40 deg.C. to +105 deg.C.

< Nordic Original (2 Mbps) > Radio Type : Transceiver Frequency of Operation : 2402 MHz - 2480 MHz Modulation : GFSK Power Supply (radio part input) : DC 1.7 V - 3.6 V Antenna type : Monopole Antenna Antenna Gain : -1.5 dBi Operation temperature range : -40 deg.C. to +105 deg.C.

< IEEE802.15.4 >

Radio Type : Transceiver Frequency of Operation : 2405 MHz - 2475 MHz Modulation : O-QPSK,DSSS Power Supply (radio part input) : DC 1.7 V - 3.6 V Antenna type : Monopole Antenna Antenna Gain : -1.5 dBi Operation temperature range : -40 deg.C. to +105 deg.C.

Test report No. : 12725753M Page : 6 of 33 Issued date : April 15, 2019

UL Japan, Inc. Kashima EMC Lab. 1614, Mushihata, Katori-shi, Chiba-ken, 289-0341 Japan Telephone : +81 478 88 6500 Facsimile : +81 478 82 3373

SECTION 3: Test specification, procedures & results 3.1 Test Specification

Radio : EN 300 328 V2.1.1 Title : Wideband transmission systems; Data transmission equipment operating in the 2.4GHz ISM

band and using wide band modulation techniques; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU

Purpose of test : Compliance with the harmonized RE directive 2014/53/EU. 3.2 Procedures and results

Item Test Procedure

Limit Remarks Worst margin

Exclusions Results

RF output power Clause 5.4.2 Clause 4.3.2.2 Conducted See Data N/A Complied a)

Power Spectral Density Clause 5.4.3 Clause 4.3.2.3 Conducted See Data N/A Complied b)

Duty cycle, Tx-sequence, Tx-gap *1)

Clause 5.4.2 Clause 4.3.2.4 Conducted - N/A N/A

Medium Utilization (MU) factor *1)

Clause 5.4.2 Clause 4.3.2.5 Conducted - N/A N/A

Adaptivity (adaptive equipment using modulations other than FHSS) *1)

Clause 5.4.6 Clause 4.3.2.6 Conducted - N/A N/A

Occupied Channel Bandwidth

Clause 5.4.7 Clause 4.3.2.7 Conducted See Data N/A Complied c)

Transmitter unwanted emissions in the out-of-band domain

Clause 5.4.8 Clause 4.3.2.8 Conducted See Data N/A Complied d)

Transmitter unwanted emissions in the spurious domain *2)

Clause 5.4.9 Clause 4.3.2.9 Radiated - N/A N/A

Receiver Spurious emissions *2)

Clause 5.4.10 Clause 4.3.2.10 Radiated - N/A N/A

Transmitter unwanted emissions in the spurious domain *3)

Clause 5.4.9 Clause 4.3.2.9 Conducted - N/A N/A

Receiver Spurious emissions *3)

Clause 5.4.10 Clause 4.3.2.10 Conducted - N/A N/A

Receiver Blocking Clause 5.4.11 Clause 4.3.2.11 Conducted See Data N/A Complied e)

Geo-location capability *4) - Clause 4.3.2.12 - - N/A N/A

Test report No. : 12725753M Page : 7 of 33 Issued date : April 15, 2019

UL Japan, Inc. Kashima EMC Lab. 1614, Mushihata, Katori-shi, Chiba-ken, 289-0341 Japan Telephone : +81 478 88 6500 Facsimile : +81 478 82 3373

Note: UL Japan, Inc.’s EMI Work Procedure 13-EM-W0420. *1) The test is not applicable since the RF output power of the EUT is less than 10 dBm (e.i.r.p.). *2) The test were not performed by the customer’s request. *3) The EUT does not have antenna connector. *4) The EUT does not have Geo-location capability. a) Refer to APPENDIX 1 (data of RF Output Power) b) Refer to APPENDIX 1 (data of Power Spectral Density

Report No. 12725753M Test place Kashima EMC Lab. No.2 Measurement Room Date February 21, 2019 Temperature / Humidity 20 deg. C / 43 % RH Engineer Kazuhiro Ando Mode Tx

BT LE 1MbpsCh S/A S/A RF Output Result Limit Margin

Temp. Volt. Freq. Maximum Total Power PowerReading Reading

[MHz] [dBm/MHz] [dBm] [dBm] [dBm/MHz] [dBm/MHz] [dB]2402.00 -3.70 -3.63 6.76 6.69 10.00 3.312440.00 -3.48 -3.41 6.91 6.84 10.00 3.162480.00 -3.26 -3.19 7.00 6.93 10.00 3.07

Result [dBm/MHz] = S/A Maximum Reading [dBm/MHz] - S/A Total Power Reading [dBm] (*1) + RF Output Power [dBm] (*2)

(*1) Integrated value of 2400 MHz to 2483.5 MHz

(*2) Refer to RF Output Power

Test Condition

nom nom

BT LE 2 MbpsCh S/A S/A RF Output Result Limit Margin

Temp. Volt. Freq. Maximum Total Power PowerReading Reading

[MHz] [dBm/MHz] [dBm] [dBm] [dBm/MHz] [dBm/MHz] [dB]2402.00 -4.97 -3.86 6.76 5.65 10.00 4.352440.00 -5.75 -4.62 6.91 5.78 10.00 4.222480.00 -5.71 -4.56 7.01 5.86 10.00 4.14

Result [dBm/MHz] = S/A Maximum Reading [dBm/MHz] - S/A Total Power Reading [dBm] (*1) + RF Output Power [dBm] (*2)

(*1) Integrated value of 2400 MHz to 2483.5 MHz

(*2) Refer to RF Output Power

Test Condition

nom nom

BT LE 125 kbpsCh S/A S/A RF Output Result Limit Margin

Temp. Volt. Freq. Maximum Total Power PowerReading Reading

[MHz] [dBm/MHz] [dBm] [dBm] [dBm/MHz] [dBm/MHz] [dB]2402.00 -2.88 -2.81 6.75 6.68 10.00 3.322440.00 -2.82 -2.75 6.90 6.83 10.00 3.172480.00 -2.60 -2.52 6.99 6.92 10.00 3.08

Result [dBm/MHz] = S/A Maximum Reading [dBm/MHz] - S/A Total Power Reading [dBm] (*1) + RF Output Power [dBm] (*2)

(*1) Integrated value of 2400 MHz to 2483.5 MHz

(*2) Refer to RF Output Power

Test Condition

nom nom

Test report No. : 12725753M Page : 8 of 33 Issued date : April 15, 2019

UL Japan, Inc. Kashima EMC Lab. 1614, Mushihata, Katori-shi, Chiba-ken, 289-0341 Japan Telephone : +81 478 88 6500 Facsimile : +81 478 82 3373

BT LE 500 kbpsCh S/A S/A RF Output Result Limit Margin

Temp. Volt. Freq. Maximum Total Power PowerReading Reading

[MHz] [dBm/MHz] [dBm] [dBm] [dBm/MHz] [dBm/MHz] [dB]2402.00 -2.33 -2.26 6.75 6.68 10.00 3.322440.00 -2.61 -2.54 6.90 6.83 10.00 3.172480.00 -2.36 -2.29 7.10 7.03 10.00 2.97

Result [dBm/MHz] = S/A Maximum Reading [dBm/MHz] - S/A Total Power Reading [dBm] (*1) + RF Output Power [dBm] (*2)

(*1) Integrated value of 2400 MHz to 2483.5 MHz

(*2) Refer to RF Output Power

Test Condition

nom nom

Power Spectral Density

Report No. 12725753M Test place Kashima EMC Lab. No.2 Measurement Room Date February 21, 2019 Temperature / Humidity 20 deg. C / 43 % RH Engineer Kazuhiro Ando Mode Tx

ANT 1 Mbps

Ch S/A S/A RF Output Result Limit MarginTemp. Volt. Freq. Maximum Total Power Power

Reading Reading[MHz] [dBm/MHz] [dBm] [dBm] [dBm/MHz] [dBm/MHz] [dB]

2402.00 -2.86 -2.83 6.75 6.72 10.00 3.282441.00 -3.07 -3.04 6.86 6.84 10.00 3.162480.00 -2.92 -2.90 6.97 6.95 10.00 3.05

Result [dBm/MHz] = S/A Maximum Reading [dBm/MHz] - S/A Total Power Reading [dBm] (*1) + RF Output Power [dBm] (*2)

(*1) Integrated value of 2400 MHz to 2483.5 MHz

(*2) Refer to RF Output Power

Test Condition

nom nom

Nordic Original 2 MbpsCh S/A S/A RF Output Result Limit Margin

Temp. Volt. Freq. Maximum Total Power PowerReading Reading

[MHz] [dBm/MHz] [dBm] [dBm] [dBm/MHz] [dBm/MHz] [dB]2402.00 -3.45 -3.11 6.76 6.42 10.00 3.582441.00 -3.67 -3.33 6.85 6.51 10.00 3.492480.00 -3.52 -3.18 6.97 6.63 10.00 3.37

Result [dBm/MHz] = S/A Maximum Reading [dBm/MHz] - S/A Total Power Reading [dBm] (*1) + RF Output Power [dBm] (*2)

(*1) Integrated value of 2400 MHz to 2483.5 MHz

(*2) Refer to RF Output Power

Test Condition

nom nom

IEEE802.15.4 250 kbpsCh S/A S/A RF Output Result Limit Margin

Temp. Volt. Freq. Maximum Total Power PowerReading Reading

[MHz] [dBm/MHz] [dBm] [dBm] [dBm/MHz] [dBm/MHz] [dB]2405.00 -3.88 -2.42 6.76 5.30 10.00 4.702440.00 -3.66 -2.22 6.84 5.41 10.00 4.592475.00 -3.55 -2.09 6.97 5.51 10.00 4.49

Result [dBm/MHz] = S/A Maximum Reading [dBm/MHz] - S/A Total Power Reading [dBm] (*1) + RF Output Power [dBm] (*2)

(*1) Integrated value of 2400 MHz to 2483.5 MHz

(*2) Refer to RF Output Power

Test Condition

nom nom

) c) Refer to APPENDIX 1 (data of Occupied Channel Bandwidth)

Test report No. : 12725753M Page : 9 of 33 Issued date : April 15, 2019

UL Japan, Inc. Kashima EMC Lab. 1614, Mushihata, Katori-shi, Chiba-ken, 289-0341 Japan Telephone : +81 478 88 6500 Facsimile : +81 478 82 3373

d) Refer to APPENDIX 1 (data of Transmitter unwanted emissions in the out-of-band domain) e) Refer to APPENDIX 1 (data of Receiver Blocking) Symbols: Complied The data of this test item has enough margin, more than the measurement uncertainty. Complied# The data of this test item meets the limits unless the measurement uncertainty is taken into consideration.

3.3 Additions or deviations to standards No addition, exclusion nor deviation has been made from the standard. 3.4 Uncertainty Although this standard determines only the limit value of uncertainty, there is no applicable rule of uncertainty in this. Therefore, the following results are derived depending on whether or not laboratory uncertainty is applied. The following uncertainties have been calculated to provide a confidence level of 95 % using a coverage factor k = 2.

Item Test Item UnitRequired

Uncertainty(+/-)

CalculatedUncertainty

(+/-)Occupied Channel Bandwidth Occupied Channel Bandwidth % 5 1.60

RF output power, conducted RF output power dB 1.5 0.74

Power Spectral Density, conducted Power Spectral Density dB 3 1.7

Unwanted Emissions, conducted

Transmitter unwanted emissionsin the out-of-band domain /Transmitter unwanted emissionsin the spurious domain (Conducted) /Receiver Spurious emissions

dB 32.2(below 6 GHz)

2.2 (6 GHz to 18 GHz)

All emissions, radiated Transmitter unwanted emissionsin the spurious domain (Radiated) /Receiver Spurious emissions (Radiated)

dB 64.7 (30 MHz to 200 MHz)

3.6 (200 MHz to 1000 MHz)4.8 (1 GHz to 13 GHz)

Temperature - deg. C 3 0.89

Supply voltages - % 3 0.42

Time

Duty cycle, Tx-sequence, Tx-gap /Medium Utilisation (MU) factor /Adaptivity (adaptive equipment usingmodulations other than FHSS)

% 5 0.012

Humidity - % Not Defined 4.6Receiver Blocking (Wanted RF Level) Receiver Blocking dB Not Defined 1.90

Receiver Blocking (Blocking Signal Level) Receiver Blocking dB Not Defined 1.6 (with WLAN Tester)

Receiver Blocking (Blocking Signal Level) Receiver Blocking dB Not Defined 2.3 (without WLAN Tester)

*Measurement uncertainties of UL Japan, Inc. do not exceed the uncertainties required in the standard.

Test report No. : 12725753M Page : 10 of 33 Issued date : April 15, 2019

UL Japan, Inc. Kashima EMC Lab. 1614, Mushihata, Katori-shi, Chiba-ken, 289-0341 Japan Telephone : +81 478 88 6500 Facsimile : +81 478 82 3373

3.5 Test Location

Test siteISED AssignedCode

Width x Depth xHeight (m)

Size of reference ground plane (m) /horizontal conducting plane

Maximummeasurementdistance

No.1 Open site 4659A-1 6.0 x 5.5 x 2.5 20 x 40 10 mNo.5 Open site 4659A-5 8.6 x 7.1 x 2.4 18 x 23 10 mNo.1 Shielded room 4659A-1 5.4 x 4.5 x 2.3 - -No.3 Shielded room - 5.4 x 3.6 x 2.3 - -No.4 Shielded Room - 6.1 x 6.1 x 3.1 - -No.5 Shielded Room 4659A-5 4.2 x 3.1 x 2.5 - -No.3 Fully Anechoic Chamber - 7.0 x 3.5 x 3.5 - -No.6 Semi-anechoic Chamber 4659A-6 8.5 x 5.5 x 5.2 - 3 mNo.10 Semi-anechoic Chamber 4659A-10 18.4 x 9.9 x 7.7 - 10 mNo.11 Semi-anechoic Chamber 4659A-7 9.0 x 6.5 x 5.2 - 3 mNo.1 Measurement room - 5.0 x 3.7 x 2.6 - -No.2 Measurement room - 4.3 x 4.4 x 2.7 - -No.3 Measurement room - 4.5 x 5.3 x 2.7 - -

UL Japan, Inc. Kashima EMC Lab.1614 Mushihata, Katori-shi, Chiba-ken, 289-0341 JAPANTelephone: +81 478 88 6500, Facsimile: +81 478 82 3373JAB Accreditation No.:RTL02610 / FCC Test Firm Registration Number: 910230

3.6 Test data, Test instruments, and Test set up Refer to APPENDIX.

Test report No. : 12725753M Page : 11 of 33 Issued date : April 15, 2019

UL Japan, Inc. Kashima EMC Lab. 1614, Mushihata, Katori-shi, Chiba-ken, 289-0341 Japan Telephone : +81 478 88 6500 Facsimile : +81 478 82 3373

SECTION 4: Operation of E.U.T. during testing 4.1 Operating Mode(s)

Mode Remarks* Bluetooth (BT) Low Energy (LE) 1 Mbps Maximum Packet Size, PRBS9 Bluetooth (BT) Low Energy (LE) 2 Mbps Maximum Packet Size, PRBS9 Bluetooth (BT) Low Energy (LE) 125 kbps Maximum Packet Size, PRBS9 Bluetooth (BT) Low Energy (LE) 500 kbps Maximum Packet Size, PRBS9 ANT 1 Mbps 1 Mbps Nordic Original 2 Mbps 2 Mbps IEEE802.15.4 250 kbps 250 kbps *EUT has the power settings by the software as follows; - Power Setting: +8 dBm - Software: 10_BLE_TEST_tool-BT5.xls (BT LE mode) Radio_test_tool_20180927.xls (ANT, Nordic Original and IEEE802.15.4 mode) Blocking_tool_20190213.xls (Receiver blocking test only) This setting of software is the worst case. Any conditions under the normal use do not exceed the condition of setting. In addition, end users cannot change the settings of the output power of the product.

Details of Operating Mode(s)

Test item Operating mode Tested frequency RF output power, Power Spectral Density

Transmitting (Tx) BT LE 1 Mbps Transmitting (Tx) BT LE 2 Mbps Transmitting (Tx) BT LE 125 kbps Transmitting (Tx) BT LE 500 kbps

2402 MHz 2440 MHz 2480 MHz

Transmitting (Tx) ANT 1 Mbps Transmitting (Tx) Nordic Original 2 Mbps

2402 MHz 2441 MHz 2480 MHz

Transmitting (Tx) IEEE802.15.4 250 kbps 2405 MHz 2440 MHz 2475 MHz

Occupied channel bandwidth, Transmitter unwanted emissions in the out-of-band domain,

Transmitting (Tx) BT LE 1 Mbps Transmitting (Tx) BT LE 2 Mbps Transmitting (Tx) BT LE 125 kbps Transmitting (Tx) BT LE 500 kbps Transmitting (Tx) ANT 1 Mbps Transmitting (Tx) Nordic Original 2 Mbps

2402 MHz 2480 MHz

Transmitting (Tx) IEEE802.15.4 250 kbps 2405 MHz 2475 MHz

Receiver blocking

Communication ANT 1Mbps *1) 2402 MHz 2480 MHz

*1) Test was conducted in the mode with the lowest nominal channel bandwidth.

Extreme test condition Temperature -40 deg. C to +105 deg. C : operating temperature range of EUT Voltage Vnom : DC 3.0 V

Test report No. : 12725753M Page : 12 of 33 Issued date : April 15, 2019

UL Japan, Inc. Kashima EMC Lab. 1614, Mushihata, Katori-shi, Chiba-ken, 289-0341 Japan Telephone : +81 478 88 6500 Facsimile : +81 478 82 3373

4.2 Configuration and peripherals Except for Receiver blocking test

* Cabling and setup(s) were taken into consideration and test data was taken under worse case conditions. Description of EUTand Support equipment

No. Item Model number Serial number Manufacturer Remarks

A Bluetooth low energy / ANT / 802.15.4 Module

EYSKJN 10 *1) 11 *2)

TAIYO YUDEN EUT

B DC Power Supply GSV3000 60646742 DIAMOND

ANTENNA -

C PC CF-T2 T0993Z Panasonic - D AC Adaptor CF-AA1625A 1625AM406Z21913F Panasonic - E Evaluation Board TE8926 - TAIYO YUDEN -

*1) Used for BT LE mode *2) Used for ANT, Nordic Original mode and IEEE802.15.4 mode List of cables used

No. Name Length (m) Shield Remarks Cable Connector 1 USB Cable 1.5 Shielded Shielded - 2 DC Cable 0.5 + 1.2 Unshielded Unshielded - 3 AC Cable 1.7 Unshielded Unshielded - 4 DC Cable 1.2 Unshielded Unshielded - 5 AC Cable 0.9 Unshielded Unshielded -

C

1

AC 100 V / 50Hz

2

B

DC 3 V

AC 100 V / 50Hz

D

3 4 5

E

A

Test report No. : 12725753M Page : 13 of 33 Issued date : April 15, 2019

UL Japan, Inc. Kashima EMC Lab. 1614, Mushihata, Katori-shi, Chiba-ken, 289-0341 Japan Telephone : +81 478 88 6500 Facsimile : +81 478 82 3373

Receiver blocking test

* Cabling and setup(s) were taken into consideration and test data was taken under worse case conditions. Description of EUT and Support equipment

No. Item Model number Serial number Manufacturer Remarks

A Bluetooth low energy / ANT / 802.15.4 Module

EYSKJN 9 TAIYO YUDEN EUT

B DC Power Supply GSV3000 60646742 DIAMOND - C PC CF-T2 T0993Z Panasonic - D AC Adaptor CF-AA1625A 1625AM406Z21913F Panasonic - E Evaluation Board TE8926 - TAIYO YUDEN -

F Bluetooth low energy / ANT / 802.15.4 Module

EYSKJN 10 TAIYO YUDEN -

G Evaluation Board TE8926 - TAIYO YUDEN - H DC Power Supply PAD35-10L 1900700 KIKUSUI -

List of cables used

No. Name Length (m) Shield Remarks Cable Connector

1 USB Cable 1.5 Shielded Shielded - 2 DC Cable 0.5 Unshielded Unshielded - 3 AC Cable 1.7 Unshielded Unshielded - 4 DC Cable 1.2 Unshielded Unshielded - 5 AC Cable 0.9 Unshielded Unshielded - 6 USB Cable 2.0 Shielded Shielded - 7 DC Cable 0.5 Unshielded Unshielded - 8 AC Cable 2.8 Unshielded Unshielded -

C

1

AC 100 V / 50Hz

2

B

DC 3 V

AC 100 V / 50Hz

D

3 4 5

E

A

G

F

6 7

H

8

Test report No. : 12725753M Page : 14 of 33 Issued date : April 15, 2019

UL Japan, Inc. Kashima EMC Lab. 1614, Mushihata, Katori-shi, Chiba-ken, 289-0341 Japan Telephone : +81 478 88 6500 Facsimile : +81 478 82 3373

SECTION 5: Antenna Terminal Conducted Tests Test Procedure The tests were made with below setting connected to the antenna port.

The test results are rounded off to two decimals place, so some differences might be observed. The equipment and cables were not used for factor 0.0 dB of the data sheets. Test data : APPENDIX Test result : Pass

Test Instrument used Remark RF Output Power Power Meter Normal and Extreme conditions Power Spectral Density Spectrum Analyzer Normal condition Occupied Channel Bandwidth

Spectrum Analyzer Normal condition

Transmitter unwanted emissions in the out-of band domain

Spectrum Analyzer Normal conditions - Detector mode: RMS - Trace: Max Hold - Band power was used on behalf of the time domain power function. - Filter mode: Gaussian Filter Since the data in this test report has enough margin

Receiver Blocking - Normal condition

Test report No. : 12725753M Page : 15 of 33 Issued date : April 15, 2019

UL Japan, Inc. Kashima EMC Lab. 1614, Mushihata, Katori-shi, Chiba-ken, 289-0341 Japan Telephone : +81 478 88 6500 Facsimile : +81 478 82 3373

APPENDIX 1: Test data

RF Output Power

Report No. 12725753M Test place Kashima EMC Lab. No.2 Measurement Room Date February 21, 2019 February 25, 2019 Temperature / Humidity 20 deg. C / 43 % RH 22 deg. C / 40 % RH Engineer Kazuhiro Ando Kazuhiro Ando Mode Tx

BT LE 1 Mbps

Freq. P/M (AV) Cable Atten. Antenna Result Limit MarginTemp. Volt. Reading Loss Loss Gain

[MHz] [dBm] [dB] [dB] [dBi] [dBm] [dBm] [dB]2402.0 -3.41 1.63 10.04 -1.50 6.76 20.00 13.242440.0 -3.28 1.64 10.05 -1.50 6.91 20.00 13.092480.0 -3.20 1.65 10.05 -1.50 7.00 20.00 13.002402.0 -2.93 1.63 10.04 -1.50 7.24 20.00 12.762440.0 -2.85 1.64 10.05 -1.50 7.34 20.00 12.662480.0 -2.74 1.65 10.05 -1.50 7.46 20.00 12.542402.0 -4.18 1.63 10.04 -1.50 5.99 20.00 14.012440.0 -4.14 1.64 10.05 -1.50 6.05 20.00 13.952480.0 -4.07 1.65 10.05 -1.50 6.13 20.00 13.87

Result = Reading + Cable Loss (including the cable(s) customer supplied) + Attenuator Loss + Antenna Gain

nom

Test Condition

nom nom

min

max nom

BT LE 2 MbpsFreq. P/M (AV) Cable Atten. Antenna Result Limit Margin

Temp. Volt. Reading Loss Loss Gain[MHz] [dBm] [dB] [dB] [dBi] [dBm] [dBm] [dB]2402.0 -3.41 1.63 10.04 -1.50 6.76 20.00 13.242440.0 -3.28 1.64 10.05 -1.50 6.91 20.00 13.092480.0 -3.19 1.65 10.05 -1.50 7.01 20.00 12.992402.0 -2.93 1.63 10.04 -1.50 7.24 20.00 12.762440.0 -2.85 1.64 10.05 -1.50 7.34 20.00 12.662480.0 -2.73 1.65 10.05 -1.50 7.47 20.00 12.532402.0 -4.17 1.63 10.04 -1.50 6.00 20.00 14.002440.0 -4.14 1.64 10.05 -1.50 6.05 20.00 13.952480.0 -4.06 1.65 10.05 -1.50 6.14 20.00 13.86

Result = Reading + Cable Loss (including the cable(s) customer supplied) + Attenuator Loss + Antenna Gain

nom

Test Condition

nom nom

min

max nom

BT LE 125 kbps

Freq. P/M (AV) Cable Atten. Antenna Result Limit MarginTemp. Volt. Reading Loss Loss Gain

[MHz] [dBm] [dB] [dB] [dBi] [dBm] [dBm] [dB]2402.0 -3.42 1.63 10.04 -1.50 6.75 20.00 13.252440.0 -3.29 1.64 10.05 -1.50 6.90 20.00 13.102480.0 -3.21 1.65 10.05 -1.50 6.99 20.00 13.012402.0 -2.94 1.63 10.04 -1.50 7.23 20.00 12.772440.0 -2.85 1.64 10.05 -1.50 7.34 20.00 12.662480.0 -2.75 1.65 10.05 -1.50 7.45 20.00 12.552402.0 -4.20 1.63 10.04 -1.50 5.97 20.00 14.032440.0 -4.16 1.64 10.05 -1.50 6.03 20.00 13.972480.0 -4.08 1.65 10.05 -1.50 6.12 20.00 13.88

Result = Reading + Cable Loss (including the cable(s) customer supplied) + Attenuator Loss + Antenna Gain

max nom

nom

Test Condition

nom nom

min

Test report No. : 12725753M Page : 16 of 33 Issued date : April 15, 2019

UL Japan, Inc. Kashima EMC Lab. 1614, Mushihata, Katori-shi, Chiba-ken, 289-0341 Japan Telephone : +81 478 88 6500 Facsimile : +81 478 82 3373

RF Output Power

Report No. 12725753M Test place Kashima EMC Lab. No.2 Measurement Room Date February 21, 2019 February 25, 2019 Temperature / Humidity 20 deg. C / 43 % RH 22 deg. C / 40 % RH Engineer Kazuhiro Ando Kazuhiro Ando Mode Tx

BT LE 500 kbps

Freq. P/M (AV) Cable Atten. Antenna Result Limit MarginTemp. Volt. Reading Loss Loss Gain

[MHz] [dBm] [dB] [dB] [dBi] [dBm] [dBm] [dB]2402.0 -3.42 1.63 10.04 -1.50 6.75 20.00 13.252440.0 -3.29 1.64 10.05 -1.50 6.90 20.00 13.102480.0 -3.10 1.65 10.05 -1.50 7.10 20.00 12.902402.0 -2.94 1.63 10.04 -1.50 7.23 20.00 12.772440.0 -2.85 1.64 10.05 -1.50 7.34 20.00 12.662480.0 -2.74 1.65 10.05 -1.50 7.46 20.00 12.542402.0 -4.20 1.63 10.04 -1.50 5.97 20.00 14.032440.0 -4.15 1.64 10.05 -1.50 6.04 20.00 13.962480.0 -4.07 1.65 10.05 -1.50 6.13 20.00 13.87

Result = Reading + Cable Loss (including the cable(s) customer supplied) + Attenuator Loss + Antenna Gain

nom

Test Condition

nom nom

min

max nom

ANT 1 MbpsFreq. P/M (AV) Cable Atten. Antenna Result Limit Margin

Temp. Volt. Reading Loss Loss Gain[MHz] [dBm] [dB] [dB] [dBi] [dBm] [dBm] [dB]2402.0 -3.42 1.63 10.04 -1.50 6.75 20.00 13.252441.0 -3.33 1.64 10.05 -1.50 6.86 20.00 13.142480.0 -3.23 1.65 10.05 -1.50 6.97 20.00 13.032402.0 -3.09 1.63 10.04 -1.50 7.08 20.00 12.922441.0 -2.91 1.64 10.05 -1.50 7.28 20.00 12.722480.0 -2.76 1.65 10.05 -1.50 7.44 20.00 12.562402.0 -4.11 1.63 10.04 -1.50 6.06 20.00 13.942441.0 -3.99 1.64 10.05 -1.50 6.20 20.00 13.802480.0 -3.91 1.65 10.05 -1.50 6.29 20.00 13.71

Result = Reading + Cable Loss (including the cable(s) customer supplied) + Attenuator Loss + Antenna Gain

nom

Test Condition

nom nom

min

max nom

Nordic Original 2 Mbps

Freq. P/M (AV) Cable Atten. Antenna Result Limit MarginTemp. Volt. Reading Loss Loss Gain

[MHz] [dBm] [dB] [dB] [dBi] [dBm] [dBm] [dB]

2402.0 -3.41 1.63 10.04 -1.50 6.76 20.00 13.242441.0 -3.34 1.64 10.05 -1.50 6.85 20.00 13.152480.0 -3.23 1.65 10.05 -1.50 6.97 20.00 13.032402.0 -3.09 1.63 10.04 -1.50 7.08 20.00 12.922441.0 -2.91 1.64 10.05 -1.50 7.28 20.00 12.722480.0 -2.77 1.65 10.05 -1.50 7.43 20.00 12.572402.0 -4.15 1.63 10.04 -1.50 6.02 20.00 13.982441.0 -4.02 1.64 10.05 -1.50 6.17 20.00 13.832480.0 -3.94 1.65 10.05 -1.50 6.26 20.00 13.74

Result = Reading + Cable Loss (including the cable(s) customer supplied) + Attenuator Loss + Antenna Gain

nom

Test Condition

nom nom

min

max nom

Test report No. : 12725753M Page : 17 of 33 Issued date : April 15, 2019

UL Japan, Inc. Kashima EMC Lab. 1614, Mushihata, Katori-shi, Chiba-ken, 289-0341 Japan Telephone : +81 478 88 6500 Facsimile : +81 478 82 3373

RF Output Power

Report No. 12725753M Test place Kashima EMC Lab. No.2 Measurement Room Date February 21, 2019 February 25, 2019 Temperature / Humidity 20 deg. C / 43 % RH 22 deg. C / 40 % RH Engineer Kazuhiro Ando Kazuhiro Ando Mode Tx

IEEE802.15.4 250 kbps

Freq. P/M (AV) Cable Atten. Antenna Result Limit MarginTemp. Volt. Reading Loss Loss Gain

[MHz] [dBm] [dB] [dB] [dBi] [dBm] [dBm] [dB]

2405.0 -3.41 1.63 10.04 -1.50 6.76 20.00 13.242440.0 -3.35 1.64 10.05 -1.50 6.84 20.00 13.162475.0 -3.23 1.65 10.05 -1.50 6.97 20.00 13.032405.0 -3.06 1.63 10.04 -1.50 7.11 20.00 12.892440.0 -2.91 1.64 10.05 -1.50 7.28 20.00 12.722475.0 -2.77 1.65 10.05 -1.50 7.43 20.00 12.572405.0 -4.14 1.63 10.04 -1.50 6.03 20.00 13.972440.0 -4.02 1.64 10.05 -1.50 6.17 20.00 13.832475.0 -3.94 1.65 10.05 -1.50 6.26 20.00 13.74

Result = Reading + Cable Loss (including the cable(s) customer supplied) + Attenuator Loss + Antenna Gain

max nom

nom

Test Condition

nom nom

min

Test report No. : 12725753M Page : 18 of 33 Issued date : April 15, 2019

UL Japan, Inc. Kashima EMC Lab. 1614, Mushihata, Katori-shi, Chiba-ken, 289-0341 Japan Telephone : +81 478 88 6500 Facsimile : +81 478 82 3373

Power Spectral Density

Report No. 12725753M Test place Kashima EMC Lab. No.2 Measurement Room Date February 21, 2019 Temperature / Humidity 20 deg. C / 43 % RH Engineer Kazuhiro Ando Mode Tx

BT LE 1MbpsCh S/A S/A RF Output Result Limit Margin

Temp. Volt. Freq. Maximum Total Power PowerReading Reading

[MHz] [dBm/MHz] [dBm] [dBm] [dBm/MHz] [dBm/MHz] [dB]2402.00 -3.70 -3.63 6.76 6.69 10.00 3.312440.00 -3.48 -3.41 6.91 6.84 10.00 3.162480.00 -3.26 -3.19 7.00 6.93 10.00 3.07

Result [dBm/MHz] = S/A Maximum Reading [dBm/MHz] - S/A Total Power Reading [dBm] (*1) + RF Output Power [dBm] (*2)

(*1) Integrated value of 2400 MHz to 2483.5 MHz

(*2) Refer to RF Output Power

Test Condition

nom nom

BT LE 2 MbpsCh S/A S/A RF Output Result Limit Margin

Temp. Volt. Freq. Maximum Total Power PowerReading Reading

[MHz] [dBm/MHz] [dBm] [dBm] [dBm/MHz] [dBm/MHz] [dB]2402.00 -4.97 -3.86 6.76 5.65 10.00 4.352440.00 -5.75 -4.62 6.91 5.78 10.00 4.222480.00 -5.71 -4.56 7.01 5.86 10.00 4.14

Result [dBm/MHz] = S/A Maximum Reading [dBm/MHz] - S/A Total Power Reading [dBm] (*1) + RF Output Power [dBm] (*2)

(*1) Integrated value of 2400 MHz to 2483.5 MHz

(*2) Refer to RF Output Power

Test Condition

nom nom

BT LE 125 kbpsCh S/A S/A RF Output Result Limit Margin

Temp. Volt. Freq. Maximum Total Power PowerReading Reading

[MHz] [dBm/MHz] [dBm] [dBm] [dBm/MHz] [dBm/MHz] [dB]2402.00 -2.88 -2.81 6.75 6.68 10.00 3.322440.00 -2.82 -2.75 6.90 6.83 10.00 3.172480.00 -2.60 -2.52 6.99 6.92 10.00 3.08

Result [dBm/MHz] = S/A Maximum Reading [dBm/MHz] - S/A Total Power Reading [dBm] (*1) + RF Output Power [dBm] (*2)

(*1) Integrated value of 2400 MHz to 2483.5 MHz

(*2) Refer to RF Output Power

Test Condition

nom nom

BT LE 500 kbpsCh S/A S/A RF Output Result Limit Margin

Temp. Volt. Freq. Maximum Total Power PowerReading Reading

[MHz] [dBm/MHz] [dBm] [dBm] [dBm/MHz] [dBm/MHz] [dB]2402.00 -2.33 -2.26 6.75 6.68 10.00 3.322440.00 -2.61 -2.54 6.90 6.83 10.00 3.172480.00 -2.36 -2.29 7.10 7.03 10.00 2.97

Result [dBm/MHz] = S/A Maximum Reading [dBm/MHz] - S/A Total Power Reading [dBm] (*1) + RF Output Power [dBm] (*2)

(*1) Integrated value of 2400 MHz to 2483.5 MHz

(*2) Refer to RF Output Power

Test Condition

nom nom

Test report No. : 12725753M Page : 19 of 33 Issued date : April 15, 2019

UL Japan, Inc. Kashima EMC Lab. 1614, Mushihata, Katori-shi, Chiba-ken, 289-0341 Japan Telephone : +81 478 88 6500 Facsimile : +81 478 82 3373

Power Spectral Density

Report No. 12725753M Test place Kashima EMC Lab. No.2 Measurement Room Date February 21, 2019 Temperature / Humidity 20 deg. C / 43 % RH Engineer Kazuhiro Ando Mode Tx

ANT 1 Mbps

Ch S/A S/A RF Output Result Limit MarginTemp. Volt. Freq. Maximum Total Power Power

Reading Reading[MHz] [dBm/MHz] [dBm] [dBm] [dBm/MHz] [dBm/MHz] [dB]

2402.00 -2.86 -2.83 6.75 6.72 10.00 3.282441.00 -3.07 -3.04 6.86 6.84 10.00 3.162480.00 -2.92 -2.90 6.97 6.95 10.00 3.05

Result [dBm/MHz] = S/A Maximum Reading [dBm/MHz] - S/A Total Power Reading [dBm] (*1) + RF Output Power [dBm] (*2)

(*1) Integrated value of 2400 MHz to 2483.5 MHz

(*2) Refer to RF Output Power

Test Condition

nom nom

Nordic Original 2 MbpsCh S/A S/A RF Output Result Limit Margin

Temp. Volt. Freq. Maximum Total Power PowerReading Reading

[MHz] [dBm/MHz] [dBm] [dBm] [dBm/MHz] [dBm/MHz] [dB]2402.00 -3.45 -3.11 6.76 6.42 10.00 3.582441.00 -3.67 -3.33 6.85 6.51 10.00 3.492480.00 -3.52 -3.18 6.97 6.63 10.00 3.37

Result [dBm/MHz] = S/A Maximum Reading [dBm/MHz] - S/A Total Power Reading [dBm] (*1) + RF Output Power [dBm] (*2)

(*1) Integrated value of 2400 MHz to 2483.5 MHz

(*2) Refer to RF Output Power

Test Condition

nom nom

IEEE802.15.4 250 kbpsCh S/A S/A RF Output Result Limit Margin

Temp. Volt. Freq. Maximum Total Power PowerReading Reading

[MHz] [dBm/MHz] [dBm] [dBm] [dBm/MHz] [dBm/MHz] [dB]2405.00 -3.88 -2.42 6.76 5.30 10.00 4.702440.00 -3.66 -2.22 6.84 5.41 10.00 4.592475.00 -3.55 -2.09 6.97 5.51 10.00 4.49

Result [dBm/MHz] = S/A Maximum Reading [dBm/MHz] - S/A Total Power Reading [dBm] (*1) + RF Output Power [dBm] (*2)

(*1) Integrated value of 2400 MHz to 2483.5 MHz

(*2) Refer to RF Output Power

Test Condition

nom nom

Test report No. : 12725753M Page : 20 of 33 Issued date : April 15, 2019

UL Japan, Inc. Kashima EMC Lab. 1614, Mushihata, Katori-shi, Chiba-ken, 289-0341 Japan Telephone : +81 478 88 6500 Facsimile : +81 478 82 3373

Occupied Channel Bandwidth

Report No. 12725753M Test place Kashima EMC Lab. No.2 Measurement Room Date February 21, 2019 Temperature / Humidity 20 deg. C / 43 % RH Engineer Kazuhiro Ando Mode Tx BT LE 1Mbps

Frequency Bandwidth Result Limit[MHz] [MHz] [MHz] [MHz]2402 1.0577 2401.4712 > 24002480 1.0626 2480.5313 < 2483.5

Tx 2402 MHz Tx 2480 MHz

Test report No. : 12725753M Page : 21 of 33 Issued date : April 15, 2019

UL Japan, Inc. Kashima EMC Lab. 1614, Mushihata, Katori-shi, Chiba-ken, 289-0341 Japan Telephone : +81 478 88 6500 Facsimile : +81 478 82 3373

Occupied Channel Bandwidth

Report No. 12725753M Test place Kashima EMC Lab. No.2 Measurement Room Date February 21, 2019 Temperature / Humidity 20 deg. C / 43 % RH Engineer Kazuhiro Ando Mode Tx BT LE 2 Mbps

Frequency Bandwidth Result Limit[MHz] [MHz] [MHz] [MHz]2402 2.0552 2400.9724 > 24002480 2.0649 2481.0325 < 2483.5

Tx 2402 MHz Tx 2480 MHz

Test report No. : 12725753M Page : 22 of 33 Issued date : April 15, 2019

UL Japan, Inc. Kashima EMC Lab. 1614, Mushihata, Katori-shi, Chiba-ken, 289-0341 Japan Telephone : +81 478 88 6500 Facsimile : +81 478 82 3373

Occupied Channel Bandwidth

Report No. 12725753M Test place Kashima EMC Lab. No.2 Measurement Room Date February 21, 2019 Temperature / Humidity 20 deg. C / 43 % RH Engineer Kazuhiro Ando Mode Tx BT LE 125 kbps

Frequency Bandwidth Result Limit[MHz] [MHz] [MHz] [MHz]2402 1.0524 2401.4738 > 24002480 1.0525 2480.5263 < 2483.5

Tx 2402 MHz Tx 2480 MHz

Test report No. : 12725753M Page : 23 of 33 Issued date : April 15, 2019

UL Japan, Inc. Kashima EMC Lab. 1614, Mushihata, Katori-shi, Chiba-ken, 289-0341 Japan Telephone : +81 478 88 6500 Facsimile : +81 478 82 3373

Occupied Channel Bandwidth

Report No. 12725753M Test place Kashima EMC Lab. No.2 Measurement Room Date February 21, 2019 Temperature / Humidity 20 deg. C / 43 % RH Engineer Kazuhiro Ando Mode Tx BT LE 500 kbps

Frequency Bandwidth Result Limit[MHz] [MHz] [MHz] [MHz]2402 1.0436 2401.4782 > 24002480 1.0489 2480.5245 < 2483.5

Tx 2402 MHz Tx 2480 MHz

Test report No. : 12725753M Page : 24 of 33 Issued date : April 15, 2019

UL Japan, Inc. Kashima EMC Lab. 1614, Mushihata, Katori-shi, Chiba-ken, 289-0341 Japan Telephone : +81 478 88 6500 Facsimile : +81 478 82 3373

Occupied Channel Bandwidth

Report No. 12725753M Test place Kashima EMC Lab. No.2 Measurement Room Date February 21, 2019 Temperature / Humidity 20 deg. C / 43 % RH Engineer Kazuhiro Ando Mode Tx ANT 1 Mbps

Frequency Bandwidth Result Limit[MHz] [MHz] [MHz] [MHz]2402 0.9053 2401.5473 > 24002480 0.9075 2480.4538 < 2483.5

Tx 2402 MHz Tx 2480 MHz

Test report No. : 12725753M Page : 25 of 33 Issued date : April 15, 2019

UL Japan, Inc. Kashima EMC Lab. 1614, Mushihata, Katori-shi, Chiba-ken, 289-0341 Japan Telephone : +81 478 88 6500 Facsimile : +81 478 82 3373

Occupied Channel Bandwidth

Report No. 12725753M Test place Kashima EMC Lab. No.2 Measurement Room Date February 21, 2019 Temperature / Humidity 20 deg. C / 43 % RH Engineer Kazuhiro Ando Mode Tx Nordic Original 2 Mbps

Frequency Bandwidth Result Limit[MHz] [MHz] [MHz] [MHz]2402 1.7637 2401.1182 > 24002480 1.7723 2480.8862 < 2483.5

Tx 2402 MHz Tx 2480 MHz

Test report No. : 12725753M Page : 26 of 33 Issued date : April 15, 2019

UL Japan, Inc. Kashima EMC Lab. 1614, Mushihata, Katori-shi, Chiba-ken, 289-0341 Japan Telephone : +81 478 88 6500 Facsimile : +81 478 82 3373

Occupied Channel Bandwidth

Report No. 12725753M Test place Kashima EMC Lab. No.2 Measurement Room Date February 21, 2019 Temperature / Humidity 20 deg. C / 43 % RH Engineer Kazuhiro Ando Mode Tx IEEE802.15.4 250 kbps

Frequency Bandwidth Result Limit[MHz] [MHz] [MHz] [MHz]2405 2.2104 2403.8948 > 24002475 2.2248 2476.1124 < 2483.5

Tx 2405 MHz Tx 2475 MHz

Test report No. : 12725753M Page : 27 of 33 Issued date : April 15, 2019

UL Japan, Inc. Kashima EMC Lab. 1614, Mushihata, Katori-shi, Chiba-ken, 289-0341 Japan Telephone : +81 478 88 6500 Facsimile : +81 478 82 3373

Transmitter unwanted emissions in the out-of-band domain

Report No. 12725753M Test place Kashima EMC Lab. No.2 Measurement Room Date February 21, 2019 Temperature / Humidity 20 deg. C / 43 % RH Engineer Kazuhiro Ando Mode Tx

BT LE 1 MbpsFrequency S/A (AV) Cable Atten. Antenna Result Limit Margin Remarks

Reading Loss Loss Gain[MHz] [dBm/MHz] [dB] [dB] [dBi] [dBm/MHz] [dBm/MHz] [dB]2398.4 -55.64 1.63 10.04 -1.50 -45.47 -20.00 25.47 Lowest ch 2400 MHz - 2 BW2399.5 -50.13 1.63 10.04 -1.50 -39.96 -10.00 29.96 Lowest ch 2400 MHz - BW2484.0 -57.23 1.65 10.05 -1.50 -47.03 -10.00 37.03 Highest ch 2483.5 MHz + BW2485.1 -60.21 1.65 10.05 -1.50 -50.01 -20.00 30.01 Highest ch 2483.5 MHz + 2 BW

BT LE 2 MbpsFrequency S/A (AV) Cable Atten. Antenna Result Limit Margin Remarks

Reading Loss Loss Gain[MHz] [dBm/MHz] [dB] [dB] [dBi] [dBm/MHz] [dBm/MHz] [dB]2397.4 -55.34 1.63 10.04 -1.50 -45.17 -20.00 25.17 Lowest ch 2400 MHz - 2 BW2399.5 -39.35 1.63 10.04 -1.50 -29.18 -10.00 19.18 Lowest ch 2400 MHz - BW2484.0 -53.57 1.65 10.05 -1.50 -43.37 -10.00 33.37 Highest ch 2483.5 MHz + BW2486.1 -57.26 1.65 10.05 -1.50 -47.06 -20.00 27.06 Highest ch 2483.5 MHz + 2 BW

BT LE 125 kbpsFrequency S/A (AV) Cable Atten. Antenna Result Limit Margin Remarks

Reading Loss Loss Gain[MHz] [dBm/MHz] [dB] [dB] [dBi] [dBm/MHz] [dBm/MHz] [dB]2398.4 -58.19 1.63 10.04 -1.50 -48.02 -20.00 28.02 Lowest ch 2400 MHz - 2 BW2399.5 -52.62 1.63 10.04 -1.50 -42.45 -10.00 32.45 Lowest ch 2400 MHz - BW2484.0 -59.93 1.65 10.05 -1.50 -49.73 -10.00 39.73 Highest ch 2483.5 MHz + BW2485.1 -62.86 1.65 10.05 -1.50 -52.66 -20.00 32.66 Highest ch 2483.5 MHz + 2 BW

BT LE 500 kbpsFrequency S/A (AV) Cable Atten. Antenna Result Limit Margin Remarks

Reading Loss Loss Gain[MHz] [dBm/MHz] [dB] [dB] [dBi] [dBm/MHz] [dBm/MHz] [dB]2398.5 -54.48 1.63 10.04 -1.50 -44.31 -20.00 24.31 Lowest ch 2400 MHz - 2 BW2399.5 -48.69 1.63 10.04 -1.50 -38.52 -10.00 28.52 Lowest ch 2400 MHz - BW2484.0 -56.08 1.65 10.05 -1.50 -45.88 -10.00 35.88 Highest ch 2483.5 MHz + BW2485.0 -58.97 1.65 10.05 -1.50 -48.77 -20.00 28.77 Highest ch 2483.5 MHz + 2 BW

Result = Reading + Cable Loss (including the cable(s) customer supplied) + Attenuator Loss + Antenna Gain

*Above test result was maximum value on each 1 BW.

Test report No. : 12725753M Page : 28 of 33 Issued date : April 15, 2019

UL Japan, Inc. Kashima EMC Lab. 1614, Mushihata, Katori-shi, Chiba-ken, 289-0341 Japan Telephone : +81 478 88 6500 Facsimile : +81 478 82 3373

Transmitter unwanted emissions in the out-of-band domain

Report No. 12725753M Test place Kashima EMC Lab. No.2 Measurement Room Date February 21, 2019 Temperature / Humidity 20 deg. C / 43 % RH Engineer Kazuhiro Ando Mode Tx

ANT 1 MbpsFrequency S/A (AV) Cable Atten. Antenna Result Limit Margin Remarks

Reading Loss Loss Gain[MHz] [dBm/MHz] [dB] [dB] [dBi] [dBm/MHz] [dBm/MHz] [dB]2398.5 -56.44 1.63 10.04 -1.50 -46.27 -20.00 26.27 Lowest ch 2400 MHz - 2 BW2399.5 -51.25 1.63 10.04 -1.50 -41.08 -10.00 31.08 Lowest ch 2400 MHz - BW2484.0 -57.53 1.65 10.05 -1.50 -47.33 -10.00 37.33 Highest ch 2483.5 MHz + BW2485.0 -59.07 1.65 10.05 -1.50 -48.87 -20.00 28.87 Highest ch 2483.5 MHz + 2 BW

Nordic Original 2 MbpsFrequency S/A (AV) Cable Atten. Antenna Result Limit Margin Remarks

Reading Loss Loss Gain[MHz] [dBm/MHz] [dB] [dB] [dBi] [dBm/MHz] [dBm/MHz] [dB]

2397.74 -55.24 1.63 10.04 -1.50 -45.07 -20.00 25.07 Lowest ch 2400 MHz - 2 BW2399.50 -43.36 1.63 10.04 -1.50 -33.19 -10.00 23.19 Lowest ch 2400 MHz - BW2484.00 -54.15 1.65 10.05 -1.50 -43.95 -10.00 33.95 Highest ch 2483.5 MHz + BW2485.77 -56.51 1.65 10.05 -1.50 -46.31 -20.00 26.31 Highest ch 2483.5 MHz + 2 BW

IEEE802.15.4 250 kbpsFrequency S/A (AV) Cable Atten. Antenna Result Limit Margin Remarks

Reading Loss Loss Gain[MHz] [dBm/MHz] [dB] [dB] [dBi] [dBm/MHz] [dBm/MHz] [dB]

2397.29 -59.32 1.63 10.04 -1.50 -49.15 -20.00 29.15 Lowest ch 2400 MHz - 2 BW2399.50 -53.75 1.63 10.04 -1.50 -43.58 -10.00 33.58 Lowest ch 2400 MHz - BW2484.00 -60.37 1.65 10.05 -1.50 -50.17 -10.00 40.17 Highest ch 2483.5 MHz + BW2486.22 -61.43 1.65 10.05 -1.50 -51.23 -20.00 31.23 Highest ch 2483.5 MHz + 2 BW

Result = Reading + Cable Loss (including the cable(s) customer supplied) + Attenuator Loss + Antenna Gain

*Above test result was maximum value on each 1 BW.

Test report No. : 12725753M Page : 29 of 33 Issued date : April 15, 2019

UL Japan, Inc. Kashima EMC Lab. 1614, Mushihata, Katori-shi, Chiba-ken, 289-0341 Japan Telephone : +81 478 88 6500 Facsimile : +81 478 82 3373

Receiver Blocking

Report No. 12725753M Test place Kashima EMC Lab. No.2 Measurement Room Date February 22, 2019 Temperature / Humidity 23 deg. C / 41 % RH Engineer Kazuhiro Ando Mode Communication ANT 1Mbps

Lowest Channel Highest ChannelPmin -96.97 -98.97

Pmin + 6 dB -90.97 -92.97

Receiver Category 2 equipment

2380 0.042503.5 0.002300 0.04

2583.5 0.002380 0.02

2503.5 0.062300 0.08

2583.5 0.04

*Pmin is the minimum level of wanted signal (in dBm) required to meet the minimum performance criterion a PER less than or equal to 10 % in the absence of any blocking signal.*The test was performed Blocking signal power levels corrected by the actual antenna assembly gain.

Pmin + 6 dB -47

HighestChannel

Wanted signal meanpower from companion

device (dBm)

MeasuredReceiver Sensitivity

(corrected by the actual antenna assembly gain)(dBm)

OperatingChannel

Wanted signal meanpower from companion

device (dBm)

Blocking signalfrequency

(MHz)

Blocking signal power(dBm) *1)

LowestChannel Pmin + 6 dB -47

Pmin + 6 dB -57

Pmin + 6 dB -57

ResultPER(%)

LimitPER(%)

≦10

≦10

*1) Blocking signal power was adjusted by assumed antenna gain 0.0 dBi since it was more severe condition.

Test report No. : 12725753M Page : 30 of 33 Issued date : April 15, 2019

UL Japan, Inc. Kashima EMC Lab. 1614, Mushihata, Katori-shi, Chiba-ken, 289-0341 Japan Telephone : +81 478 88 6500 Facsimile : +81 478 82 3373

CONDUCTED METHODS SYSTEM BLOCK DIAGRAM of Receiver Blocking

PC Bluetooth Smart / ANT Module

Power Splitters/ Combiners

Signal Generator

Attenuator

EUT

Test report No. : 12725753M Page : 31 of 33 Issued date : April 15, 2019

UL Japan, Inc. Kashima EMC Lab. 1614, Mushihata, Katori-shi, Chiba-ken, 289-0341 Japan Telephone : +81 478 88 6500 Facsimile : +81 478 82 3373

APPENDIX 2: Test instruments Test Instruments Test Item LIMS ID Description Manufacturer Model Serial Last

Calibration Date

Calibration Due Date

Cal Int

AT, RB 143643 Spectrum Analyzer AGILENT E4448A MY52490024 2018/5/23 2019/5/31 12 AT 143023 10dB Fixed Atten. WEINSCHEL 54A-10 56251 2018/5/21 2019/5/31 12

AT, RB 143110 Micro Wave Cable Suhner SUCOFLEX102 MY3773/2 2018/5/25 2019/5/31 12

AT 143181 Temperature and Humidity Chamber

ESPEC PL-1J 15004059 2018/7/9 2019/7/31 12

AT 143588 Peak Power Analyzer AGILENT 8990B MY51000276 2018/6/20 2019/6/30 12 AT 143606 Power Sensor AGILENT N1923A MY54070024 2018/6/20 2019/6/30 12

RB 168236 Signal Generator KEYSIGHT N5182B MY57280004 2018/8/8 2019/8/31 12 RB 143096 Step Attenuator AGILENT 8494B 2550A11724 2018/8/28 2019/8/31 12

RB 143095 Step Attenuator AGILENT 8495B MY41110308 2018/8/28 2019/8/31 12

RB 143590 Power Splitters /Combiners Mini-Circuits ZFSC-2-10G+ - 2018/6/22 2019/6/30 12 RB 143146 Micro Wave Cable Suhner SUCOFLEX104 144691/4 2018/6/21 2019/6/30 12

RB 142988 Micro Wave Cable Suhner SUCOFLEX102 MY3772/2 2018/5/25 2019/5/31 12

RB 143041 20dB Fixed Atten. WEINSCHEL 54A-20 41994 2018/5/21 2019/5/31 12 AT, RB 144220 Digital Multimeter Fluke Corporation 87-3 85220051 2018/10/1 2019/10/31 12

AT, RB 143537 Temperature & Humidity Indicator

A&D AD-5681 6975761 2018/7/18 2019/7/31 12

*Hyphens for Last Calibration Date, Calibration Due Date and Cal Int (month) are instruments that Calibration is not required (e.g. software), or instruments checked in advance before use. The expiration date of the calibration is the end of the expired month. All equipment is calibrated with valid calibrations. Each measurement data is traceable to the national or international standards. As for some calibrations performed after the tested dates, those test equipment have been controlled by means of an unbroken chains of calibrations. Test item: AT: Antenna Terminal Conducted test RB: Receiver Blocking test

Test report No. : 12725753M Page : 32 of 33 Issued date : April 15, 2019

UL Japan, Inc. Kashima EMC Lab. 1614, Mushihata, Katori-shi, Chiba-ken, 289-0341 Japan Telephone : +81 478 88 6500 Facsimile : +81 478 82 3373

APPENDIX 3: Photographs of test setup

Antenna terminal conducted tests other than Receiver Blocking

Test report No. : 12725753M Page : 33 of 33 Issued date : April 15, 2019

UL Japan, Inc. Kashima EMC Lab. 1614, Mushihata, Katori-shi, Chiba-ken, 289-0341 Japan Telephone : +81 478 88 6500 Facsimile : +81 478 82 3373

Receiver Blocking